ZP120N - G-TEC Asia Pacific Pte Ltd
N
120
ZP
online
UPS
1,2,3,6,10,20 kVA
•LOCAL AREA NETWORKS (LAN)
•INTERNET CENTERS (ISP/ASP/POP)
•ELECTROMEDICAL DEVICES
•SERVERS
•INDUSTRIAL PLCS
•TELECOMMUNICATION DEVICES
•DATA CENTERS
•EMERGENCY DEVICES (LIGHTS, ALARM)
•INDUSTRIAL APPLICATION
series
N
120
ZP
G-TEC is proud to introduce the upgraded superior ZP120N UPS that can deliver clean, safe and regulated power
supply to protect your critical mission equipment, so as to safeguard your valuable equipment and critical data from
any abnormal power disturbances, such as surges, blackouts and lightning strikes. ZP120N UPS power capacity
is available from 1kVA to 3kVA 1/1 (1/1 stands for single phase input and single phase output); from 6kVA to
10kVA 1/1 and from 10kVA to 20kVA 3/1 (3/1 stands for three phase input and single phase output).
COMMON FEATURES:
•Digital Signal Processor (DSP) Control
•Cold Start Function
•Strongest performance
•High Power Density
•Flexible Settings
•Internal components designed for stressing
environment
•Highest efficiency with low heat dissipation
•Long run time Model with optional battery and dedicated
super charger (KS Version)
1-3kVA 1/1
6-10kVA 1/1
10-20kVA 1/1-3/1
1kVA to 3kVA 1/1
Strongest performance
•DSP technology fully controlled
•Self monitoring and fault diagnosis
•Dual internal communications bus
•Lowest output voltage distortion
USB
EPO
Fan
Breaker
AC Input
High Power Density
•Wide input voltage range
•0.8 output power factor
•Input power factor correction and
lowest current distortion
Flexible Settings
•Selectable configuration via LCD:
online, eco-mode, frequency/voltage converter
mode (CVCF)
• EPO connector for remote emergency power off
•Standard external battery connector
•Simplified installation
Intelligent
Slot
Ext
Battery
AC Output
AC Output
RJ45
menU:
•
•
•
•
Operation Mode
Mimic
Settings Status/alarm code
• Input measures
• Battery capacity
• Output measures 6kVA to 10kVA 1/1
Strongest performance
•DSP technology fully controlled
•LCD display multi language
•Real time event logs
•Dual internal communications bus
•Reduced audible noise
High Power Density
•0,9 output power factor
•Minimum acceptable input voltage 110 Vac
USB
Flexible Settings
•Selectable configuration via LCD: online, parallel,
eco-mode and frequency/voltage converter
mode (CVCF)
•Parallelable up to 4 units with optional parallel kit
•Standard mechanical maintenance bypass
•Optional internal insulation transformer
•EPO connector for remote emergency power off
•Standard external battery connector
•Back-feed protection
EPO
menU:
Dry Contact
Intelligent
Slot
• Input information
• Operating status
Parallel
Port
• Battery information
Fan
• Load information
• Output information
10kVA to 20kVA 3/1
The 10-20kVA threephase input and single phase output is an upgrade of the ZP120N-10K-11. They have
the same technical performance with the following advantages:
•Input voltage autosensing (3ph or 1ph)
•Large cabinet suitable for more internal battery strings
Parallel Port (Optional)
•Dual inputs with separate bypass line as standard
RS232
EPO
USB
EPO
Dry Contact
Intelligent
Slot
Parallel Port
Intelligent
Slot
USB
Fan
Fan
Back Feed
Connector
Maintenance
Switch
Maintenance
Switch
Input
Breaker
Terminal
Blocks
Cover
Neutral
Switch Cover
Input
Breaker
Terminal
Blocks
Cover
ZP120N-10K-11
ZP120N-20K
INPUT SWITCHBOARD
POWERSUPPLY
OUTPUT SWITCHBOARD
LOAD
LOAD
LOAD
ETHERNETNETWORK
LOAD
ZP120N 6kVA to 20kVA UPS with optional parallel kit fitted
in parallel configuration, can meet most demanding power
requirement. Increase power availability and flexibility.
Parallel Redundancy feature provides economic power solution
for system integration. Furthermore, parallel redundancy feature
equally shares the load to maximize UPS performance, and more
secure UPS continuous operation.
Communication and Power Management Solutions
WinPower CD is packed with UPS, and can also be downloaded from the internet. It has the function to remote
monitor and control UPS, warning notifications through broadcast and mobile phone, multi-shutdown PCs, and
schedule UPS self-test. This unique software provides complete power protection for computer system during power failure. The software supports lots of O/S including Windows family, Linux, Sun Solaris 7/8/9, FreeBSD, IBM Aix
4.3x, 5.1x, and HP-UX 11.x. More than that, to offer increased benefits for our customers, we have also released
USB version MAC version on the internet.
INTERFACE OPTION:
SNMP CARD
• Power flow display for monitoring UPS status
• Scheduled system shutdown/restart
• Scheduled UPS test
• Warning notification via E-mail / Pager
• Warning notification via Broadcast
• Password security protection
• Remote Monitor / Control via LAN
RELAY CARD/AS400
MODBUS INTERFACE
• Multi-language versions: English, Germanic, French,
Italian,Spanish, Portuguese and Chinese
• Selectable User Interface (Background)
• UPS Parameter setting
• Record logs for analysis
• SNMP Network card allows management of UPS across
LAN using any of the main network communication
protocols – TCP/IP and network interface via SNMP.
N
120
ZP
Model
1kVA to 3kVA
Technical Specification
ZP120N-1K
Power Rating
ZP120N-1K-KS*
1000VA/800W
ZP120N-2K
ZP120N-2K-KS* ZP120N-3K
2000VA/1600W
ZP120N-3K-KS*
3000VA/2400W
INPUT
Rated Voltage
220Vac/230Vac/240Vac
Voltage Tolerance
110Vac-300Vac
110Vac-300Vac (± 3 %) at 50% load
165Vac-300Vac (± 3 %) at 75% load
Voltage Range
176Vac-300Vac (± 3 %) at 100% load
Frequency Range
50Hz or 60Hz auto sensing, 45-55Hz / 54-66Hz
THDi %
<5% with full load
Power Factor
Input connection
≥0.99 (I/P:220V, FULL RCD LOAD)
IEC 320, C13 10A/
250V power cord
IEC 320, C19 16A/
250V power cord
Connectors
OUTPUT
Rated voltage
200VAC**/208VAC**/220VAC/230VAC/240VAC
Voltage regulation
±2%
Rated Frequency (free running)
50/60 Hz ± 0.2 Hz
Crest Ratio
3:1
Harmonic distortion
< 3% THD, linear load
Output Waveform
Pure Sinewave
Overload Capability
105%-110%: 1 min; 110%-125%: 30 sec ; 125%-150%: 10 Sec; >150%: 1 sec
Power factor
Output connection
0,8
3 x IEC320, C13 10A/
250V output receptacles
4 x IEC320, C13 10A/
250V output receptacles
4 x IEC320, C13 10A/
250V output receptacles
BATTERIES
Type
Rating
Numbers of batteries
Back-up Time (typical load)
Sealed lead acid battery, maintenance free
12V/7Ah
3
>10 minutes
Depend on
external
battery
12V/7Ah
8
>18 minutes
Recharge time
Depend on
external
battery
12V/7Ah
8
>10 minutes
Depend on
external
battero
< 5 hours
General Characteristics
Transfer Time
0 ms
Efficiency
(online mode / Eco-mode)
88% / up to 94%
LCD Mimic Panel Status &
Information
Information: Battery Status / UPS status & alarm / Load status
Measurement: Battery voltage & current, Input / Output voltage, current & frequency
Control
4 Buttons: UPS ON / UPS OFF / SELECT / ENTER for selection of UPS voltage, Bypass
(enable or disable) CVCF mode
Dimensions (mm) L x D x H
Net Weight (kg)
Operating Temperature
Noise Level (@ 1m)
Humidity
Interface standard via Smart USB
Interface for Intelligent Slot
Compliance
145x400x220
13
7
192x460x347
31
13
31
0°C ~ 45 °C
50dB
0-95% (no condensing)
Support Windows family; Linux; Sun Solaris; IBM AIX;
Compaq True 64; SGI IRIX; Free BSB; HP-UX; MAC
SNMP / RS485 / AS400 Card/ ModBus
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5,
IEC 62040-1-1, IEC 62040-2, IEC 60950-1
* ks version are provided with battery extra charger
** Derate to 90% with 208Vac output voltage. Derate to 80% with 200Vac output voltage, derate to 60% automatically when at converter mode
Note: product specifications are subject to change without further notice.
13
ZP
120 N
Model
6kVA to 10kVA
Technical Specification
ZP120N-6K
Power Rating
ZP120N-6K-KS*
ZP120N-10K-11
6000VA/5400W
ZP120N -10K-11-KS*
10000VA/9000W
INPUT
Rated Voltage
220Vac/230Vac/240Vac
Voltage Tolerance
110Vac-276Vac
110Vac-276Vac (± 3 %) at 50% load
Voltage Range
176Vac-276Vac (± 3 %) at 100% load
Frequency Range
45-55Hz / 54-66Hz
THDi %
<5% with full load
Power Factor
≥0.99 (I/P:220V, FULL RCD LOAD)
OUTPUT
Rated voltage
208Vac**/220Vac/230Vac/240Vac
Voltage regulation
±1%
Rated Frequency AC Mode
50/60 Hz ± 0.05 Hz
Crest Ratio
3:1
Harmonic distortion
< 0,2% THD, linear load
Output Waveform
Pure Sinewave
105%-125%: 10 mins ; 125%-150%: 1 min ;
150%-170%: 10 sec ; >170%: 100 ms
Overload Capability
Parallel (with optional parallel kit)
Up to 4
Power factor
0,9
BATTERY
Type
Rating
Numbers of batteries
Back-up Time (typical load)
Sealed lead acid battery, maintenance free
12V/7Ah
20
> 10 minutes
12V/9Ah
***Depend on
external battery
Recharge time
20
>10 minutes
***Depend on
external battery
< 5 hours
General Characteristics
Transfer Time (Inverter to bypass)
0 ms
Efficiency (online mode / Eco-mode)
LCD Mimic Panel Status &
Information
Control
>92% / >96%
Information: Battery Status / UPS status & alarm / Load status
Measurement: Battery voltage & current, Input / Output voltage,
current & frequency
4 Buttons: UPS ON / UPS OFF / SELECT / ENTER for selection of UPS voltage,
Bypass (enable or disable) CVCF mode
Dimensions (mm) LxDxH
Net Weight (kg)
260x560x708
86
Operating Temperature
Interface standard via Smart USB
Interface for Intelligent Slot
Compliance
37
0°C ~ 45 °C
Noise Level (@ 1m)
Humidity
92
34
< 50dB
0-95% (no condensing)
Support Windows family; Linux; Sun Solaris; IBM AIX;
Compaq True 64; SGI IRIX; Free BSB; HP-UX; MAC
SNMP / RS485 / AS400 Card/ USB / ModBus
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5,
IEC 62040-1-1, IEC 62040-2, IEC 60950-1, ETS 300019-2-2
* ks version are provided with battery extra charger
** Derate to 90% with 208Vac output voltage, derate to 60% automatically when at converter mode
*** Optional external battery cabinet with or without battery is available upon request
Note: product specifications are subject to change without further notice.
ZP
120 N
Model
10kVA to 20kVA
Technical Specification
ZP120N-10K-31
Power Rating
ZP120N-10K-31-KS*
ZP120N-20K-31
10000VA/9000W
ZP120N-20K-31-KS*
20000VA/18000W
INPUT
Rated voltage
220VAC/230VAC/240VAC 1ph or 380/400/415 3ph (autosensing)
110Vac-276Vac (± 3%) at 50% load
1 phase input voltage range
176Vac-276Vac (± 3%) at 100% load
190Vac-478Vac (± 3%) at 50% load
3 phase input voltage range
322Vac-478Vac (± 3%) at 100% load
Frequency Range
45-55Hz / 54-66Hz
THDi %
<5% with full load
Power Factor
≥0.99 (FULL LOAD)
OUTPUT
Rated voltage
208VAC**/220VAC/230VAC/240VAC
Voltage regulation
±1%
Rated Frequency (free running)
50/60 Hz ± 0.05 Hz
Crest Ratio
3:1
Harmonic distortion
≤ 2% THD, linear load
Output Waveform
Overload Capability
Pure Sinewave
100%-110%: 5 min; 110%-130%: 1 min ; 130%-150%: 10 sec; >150%: 2 sec
Parallel (with optional parallel kit)
Up to 4
Power factor
0,9
BATTERY
Type
Rating
Sealed lead acid battery, maintenance free
12V/9Ah
12V/9Ah
Numbers of batteries in-built
24 + 24(optional)
Back-up Time (typical load)
> 12 minutes + 12
minutes(optional)
***Depend on
external battery
Recharge time
24 + 24
> 12 minutes
***Depend on
external battery
< 5 hours
General Characteristics
Transfer Time (Inverter to bypass)
0 ms
Efficiency
(online mode / Eco-mode)
>93% / up to 97%
Dimensions (mm) LxDxH
350x650x890
Net Weight (kg)
127
37
Operating Temperature
Noise Level (@ 1m)
Interface for Intelligent Slot
Compliance
39
55dB
Humidity
Interface standard via Smart USB
188
0°C ~ 45 °C
0-95% (no condensing)
Support Windows family; Linux; Sun Solaris; IBM AIX;
Compaq True 64; SGI IRIX; Free BSB; HP-UX; MAC
SNMP / RS485 / AS400 Card/ USB / ModBus
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5,
IEC 62040-1-1, IEC 62040-2, IEC 60950-1
* ks version are provided with battery extra charger
** Derate to 90% with 208Vac output voltage
*** Optional external battery cabinet with or without battery is available upon request
Note: product specifications are subject to change without further notice.
G-Tec Companies are also present worldwide with Business Partners in several countries.
G-Tec Asia Pacific Pte Ltd
60 Kaki Bukit Place, #03-05, Eunos Techpark II, Singapore 415979
Tel. +65 6555.5014 - Fax +65 6555.4105
info@gtec.com.sg
G-Tec Europe srl
Strada Marosticana, 81/13 - 36031 Povolaro (VI), Italia
Tel. +39 0444.361321 - Fax +39 0444.365191
info@gtec-power.eu
Rev. 30.12.2012
www.gtec-power.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising