Taylor Lifts SMS Catalogue 3-9
SMS PRODUCT
CATALOGUE
CONTENTS
1 TAKEDO 3VF-NXP - LIFT INVERTER
Page 3
2 TAKEDO 3VF-V20 - OPEN LOOP LIFT INVERTER
Page 6
3 TAKEDO ENERGY - DYNAMIC BRAKING REGENERATIVE UNIT
Page 7
4 HYDROVERT – VVVF FOR HYDRAULIC PUMP MOTORS
Page 8
5 HYDROBATT – BATTERY OPERATING DRIVE FOR HYDRAULIC HOME LIFT
Page 9
6 SOFT STARTER – FOR HYDRAULIC PUMP MOTORS
Page 10
7 MPU-2 – LIFT MICROPROCESSOR
Page 11
8 ECO-MPU – LIFT MICROPROCESSOR LIGHT
Page 12
9 ELECTRONIC SELECTOR – LIFT POSITION SELECTOR
Page 13
10 ECO-BRAKE – LIFT MACHINE BRAKE CONTROLLER
Page 14
11 RED-G – LIFT BACKUP UPS SYSTEM
Page 15
TAKEDO® 3VF-NXP
Inverter for speed regulation of lift motors
TAKEDO® 3VF-NXP series is a new, revolutionary generation
of drive. Beside its well known reliability, this new inverter,
is provided with the following characteristics:
- Special software for lift application working for
geared or gearless lifts with both asynchronous or
permanent magnets synchronous motors;
- Possibility to operate as rescue device if supplied
with batteries 48/96/192 Vdc:
- Open loop operating and closed loop with push-pull, line
®
driver or Sin-Cos incremental encoder, absolute EnDat or
SSI and also tacho generator.
- Power unit separated from control unit;
- Integrated choke to increase the power of the drive and
the life of its components;
- Fan with 3 modes automatic stop;
- Standard Input voltage up to 500V, which decreases
sensitivity to the extra-voltages on the mains;
- Starting current 2 times the rated one for 2 seconds every
20, 10 seconds every 20 for NXP06 and NXP14 special sizes;
- Integrated brake chopper, and EMC filter for any size;
- Automatic calculation of the deceleration space in one
floor run;
- Direct floor arrival function (closed loop only);
- Brake opening control;
- Safety brake opening and closing control;
- Motor contactors opening and closing control;
- Operating temperature 50°C;
- Safety control of brake opening;
- Maximum switching frequency: 16kHz, without derating.
■
■
■
■
■
■
■
■
SPECIFICATIONS
Power supply:380-500 Vac 3-phase 50-60 Hz.;
SIZES (kW):6/7.5/14/22/30/37/45/55/75/90;
Other sizes or voltage available on request.
Closed loop control, with 5 V line driver or 24 V push-pull incremental
®
encoder , sin-cos ,EnDat or SSI absolute and also tacho generator;
Max starts/hour: 240;
Max Output Current: 200% of the inverter rated current for 2
seconds every 20 , 10 seconds every 20 for special sizes NXP06 and NXP14.
INSTALLATION CONDITIONS
Operating temperature: -10 ÷ +50°C, Humidity: 0 ÷ 95%;
Max altitude 1000mt, over this height consider to derate the
current of 1% every 100mt (max 3000mt).
INPUTS
Three speed level inputs : HIGH, LOW, INSPECTION
(combining the 3 inputs, 7 levels of speed can be obtained);
Two inputs for UP and DOWN direction;
Input for lift RESCUE operation supplied by batteries;
Input for RUN enable;
Inputs for safety brake control;
Input for car load weight control.
OUTPUTS
Fault inverter relay; Brake control relay;
Power contactors energized control; Speed detector;
With optional board , 3 additional programmable relays.
PROTECTIONS
Overcurrent protection (immediate stop with current = 4 times
the rated one); - Overvoltage protection (immediate stop with voltage of
the DC bus, over 911V); - Earth-fault protection for motor or cables; - One
input phase missing; - Output phase missing or unbalanced output current;
- Drive overheat;
- Control of contactors between inverter and motor, etc.
OPERATING CHARACTERISTICS
Separated parameters for open and closed loop operation;
Rescue operation if supplied by batteries: minimum voltage 48V/96V in the
most favourable run direction for asynchronous/synchronous motors and
96/192V for forced run with rated torque for asynchronous/synchronous
motors.
Application either on VVVF single polarity, 4 or 4/16 poles, ACVV,
permanent magnet synchronous motor types, geared or gearless.
Extremely easy to be installed, even on high speed lift (1 floor
run, with automatic control).
Precise stop at the floor level apart from stop switch position.
Direct arrival to floor function , without low speed coasting.
ACCESSORIES AND OPTIONS
Braking resistance;
Kit for energy regeneration into the mains (Takedo Energy);
Optional board with 3 additional programmable relays;
Optional board for 48Vdc rescue operation;
Optional brake economizer NXBR board;
External reactance for EN12015:2005 conformity;
Additional kit for rescue operation in case of power failure (RED-G).
DIMENSIONS AND WEIGHT
30-37- 55-75SIZE (kW)
6
7,5-14
22
45
90
Width (mm.)
128
140
190
237
300
Height (mm.)
285
380
510
585
747
Length (mm.)
190
215
240
257
295
Weight (kg.)
5
8,1
18,5
35
58
Complies with EN81-1:1998 + Amendment A3:2009. Certificate IMQ n.716.
Taylor Lifts – SMS Product Catalogue Issue 1
Taylor Lifts – SMS Product Catalogue Issue 1
TAKEDO® 3VF-NXP
An application example
One of the many possible applications of Takedo® 3VF NXP is with a motor having an encoder mounted in an
unconventional way, that is not aligned on the motor shaft, as in the following picture.
Takedo® 3VF NXP can be used for this kind of application, in this case replacing the original tachogenerator
with an incremental encoder with REO444 type flange and with the same shaft measure, provided by SMS.
Once the ratio between the encoder roller pulley and the motor disc is approximately known, the start-up
procedure is quiet easy as for a standard PMSM machine. Some special features of the drive are available to
avoid the use of the car weight system, obtaining still a very good starting comfort.
SMS customers have several installations of this kind in operation for a number of years without any problems
and with the full satisfaction of the end user.
Taylor Lifts – SMS Product Catalogue Issue 1
TAKEDO® 3VF-V20
Open loop inverter for speed regulation of lift motors
TAKEDO® 3VF V20 is the new 100% “Made in Italy”
drive from SMS. Compact, silent and reliable, it differs
from other drives on the market for the following
features:
Oversized power components;
Extreme working temperature: 70°C at rated
current;
Built-in RS485 Modbus communication;
Built-in EMC Filter;
Self supporting keypad with 1m cable for easy
start-up operation (optional);
Front side status Led;
Built-in STO feature ( drive Safe Torque Off with 2
independent inputs ), compliant to the directive
EN 61800-5-2 ( SIL 2 )
( 1 motor contactor can be eliminated );
Lift dedicated software studied by SMS, that drives
and checks the safety brake on the low speed shaft
of the gear;
■ SPECIFICATIONS
Power supply:380-500 Vac 3-phase 50/60 Hz;
Sizes (A): 9/12/16;
Rated Current for 400V motor at 50° C outside
temperature;
Open loop (V/Hz or vector control);
Max starts/hour: 240;
Max Output Current: 200% nominal current of the inverter
for 2 seconds every 20.
■ INSTALLATION CONDITIONS
Operating temperature: -10 ÷ +50°C;
Humidity: 0÷95%;
Max altitude 1000mt, over this height consider to derate
the
current of 1% every 100mt (max. 3000m).
■ I/Os
8 digital input, 2 relay outputs, one open collector output,
one 4-20 mA analog output, expansion slot for option
boards.
■ PROTECTIONS
Overcurrent protection (immediate stop with current = 4
times the rated one).
Overvoltage protection (immediate stop with direct
voltage of the bus, over 911V);
Earth-fault protection for motor or cable;
Output phase missing or unbalanced output current;
Drive overheat;
Motor overload.
■ OPERATING FEATURES
Very few parameters to be set on lift installation:
Possibility of rescue operation if supplied by batteries:
minimum voltage 96V with the possibility to choose the
most favourable run direction, or forced run to any desired
floor;
Application either on VVVF single polarity, or 4/16 poles 2speed or ACVV;
Stopping regulation at any low speed level.
■ OPTIONS
Braking resistance;
Data setting and monitoring with removable keyboard;
Additional kit for rescue operation in case of power failure.
■ DIMENSIONS AND WEIGHT
SIZE (A)
Width (mm)
Heigth (mm)
Depth (mm)
Weight (kg)
Taylor Lifts – SMS Product Catalogue Issue 1
9/12/16
165
275
140
4.2
TAKEDO® ENERGY
Regenerative kit for inverter that recovers the braking energy
■
What is TAKEDO®- Energy?
It’s a kit made up of a special VVVF drive, mains
supply filters and metal box, for regenerating
the braking energy back into the line in the lift
systems equipped with VVVF drive.
■
How does it works?
When the motor is pulled by the load, it
generates energy: TAKEDO®- Energy takes this
energy and returns it to the AC line.
■
■
Where can it be installed?
It can be installed in any lift system equipped
with a VVVF drive.
Where does the energy go?
The energy returns to the AC line.
Of course the electricity meter doesn’t go back,
but the regenerated energy is used by the other
users connected to the same meter, such as car
light, lift control panel, motor brake, stairs light,
etc.
Taylor Lifts – SMS Product Catalogue Issue 1
■
What benefits does it bring me?
It allows you to save money in the energy bill and, at
the same time, the heat in the machine room
decreases.
In fact, the braking resistor is by-passed and all the
dissipated heat turns into electrical energy to the AC
line.
■
How much can I save on the total consumption?
The saving depends on the lift system type, on the
lift system travel, speed and car load, etc.
Generally it is between 10% and 40%.
■
Does the regenerated energy meet the EMC
Standards?
The regenerated energy has got a low harmonics
content and it is in compliance with the current EN
12015 Standard.
■
Is TAKEDO®-Energy applicable to any lift system, for
example in the hydraulic lifts?
Of course you can.
It’s useful in all the systems where the motor is
driven by a VVVF and a braking device is needed,
such as for example inclined lifts, hydraulic lifts with
pump motor which works even in the down
direction, escalators and moving walks, etc.
■
How much time do I need to install it?
The kit is supplied with metal box and connection
cables (2 meters length) included.
You have to connect only 5 wires.
The kit can be mounted even in the shaft, it doesn’t
need any kind of setting.
Generally the installation takes no more than 1 hour.
■
What do I need to know in order to choose the
proper size of TAKEDO®- Energy?
Size must be chosen referring to the braking current.
In an existing lift, 50% balanced, command an up run
with empty car, check the voltage at the ends of the
braking resistor and, using the P=V2/R formula
(where R is the resistor Ohm value), you can
calculate the necessary minimum power.
HYDROVERT
The drive for hydraulic lifts
HYDROVERT represents a new generation of
frequency converters for hydraulic lifts. Beside its
good quality/price ratio, it is provided with the
following characteristics :
- Special software for hydraulic lifts;
- Elimination of the peak starting current;
- Energy saving;
- Current cosϕ correction : 0.95 from the mains;
- Adjustable inspection speed;
- Precise stop at floor , and load independent;
- Operation in up direction only or both up and
down direction;
- Suitable for any kind of hydraulic system, new or
already existing;
- Rescue device if supplied with batteries at 96V;
- Open Loop operating only, without encoder;
- Integrated choke to increase the power factor of
the drive and the life of its components;
- Speed variable fan controlled by temperature;
- Built-in brake chopper and EMC filter for any
size.
■ SPECIFICATIONS
Power supply : 380÷500 Vac 50/60 Hz;
Open loop ONLY ( V/Hz or vector control);
Max Output Current: 110% of the rated current for 1 minute every 10.
NXL
SIZES
NXL0012
NXL0016
NXL0023
NXL0031
NXL0038
NXL0046
NXL0061
NXP
SIZES
NXP0013
NXP0032
NXP0038
NXP0045
NXP0061
NXP0072
NXP0087
NXP0105
NXP0140
NXP0168
RATED CURRENT
12 A
16 A
23 A
31 A
38 A
46 A
61 A
RATED CURRENT
14 A
27 A
38 A
45 A
61 A
72 A
87 A
105 A
140 A
168 A
MOTOR
POWER
5,5 kW
7,5 kW
11 kW
15 kW
18,5 kW
22 kW
30 kW
DIMENSIONS
(HxLxW)
128x292x190
144x391x214
144x391x214
144x391x214
195x519x237
195x519x237
195x519x237
MOTOR
POWER
6,5 kW
13 kW
18,5 kW
22 kW
30 kW
37 kW
45 kW
55 kW
75 kW
90 kW
DIMENSIONS
(HxLxW)
128x292x190
144x391x214
195x519x237
195x519x237
195x519x237
237x591x257
237x591x257
237x591x257
291x758x344
291x758x344
WEIGHT
5 Kg
8,1 Kg
8,1 Kg
8,1 Kg
18,5 Kg
18,5 Kg
18,5 Kg
WEIGHT
5 Kg
8,1 Kg
18,5 Kg
18,5 Kg
18,5 Kg
35 Kg
35 Kg
35 Kg
58 Kg
58 Kg
■ INSTALLATION CONDITIONS
Operating temperature: -10 ÷ +50°C
Humidity: 0 ÷ 95%
Max altitude 1000mt, over this height derate the current of 1% every
100mt (max 3000mt).
■ INPUT/OUTPUT
Input for UP direction;
Input for HIGH speed level
Input for INSPECTION speed level;
Input for RESCUE operation;
Input for run ENABLE;
Relay output to drive motor contactors.
■ PROTECTIONS
Overcurrent protection (immediate stop with current = 4 times
the rated one);
Overvoltage protection (immediate stop with direct voltage of the bus
higher than 911V);
Earth-fault protection for motor or cable;
Output phase missing or unbalanced output current;
Drive overheat;
Motor overload.
■ OPERATING FEATURES
Very few parameters to be set on lift installation;
Rescue operation if supplied by 96V batteries with the possibility to move
the car upward;
Suitable for any three-phase asynchronous motor;
Precise floor level with any car load condition and oil temperature
independent .
■ ACCESSORIES AND OPTIONALS
Data setting and monitoring with removable keyboard (as standard);
NXOPTAA optional board for speed control in downward direction with 1
output relay to control the DOWNWARD VALVE;
Braking resistor (needed only with downward direction speed control );
Additional kit for rescue operation in case of power failure.
Software and cables for PC connection.
Taylor Lifts – SMS Product Catalogue Issue 1
HYDROBATT
Battery operating drive for hydraulic home lifts
HYDROBATT is the battery operating drive designed
and built entirely by SMS for operating hydraulic
home lifts.
It consists of a low voltage high efficiency motor for
the pump and of a metal box that contains the
inverter, motor contactors and battery chargers.
WHY INSTALL IT ?
■ SPECIFICATIONS
- Mains power supply : 230 Vac 50/60 Hz, max. power 300W
for battery charge.
- Battery supply : 4*12 Vdc, 26 Ah(min.).
- Inverter sizes : 60 A, 90 A, values at 50°C ambient.
- Open loop V/f control with torque boost.
- Average autonomy : 25 upward travels with 26Ah batteries
and 50 travels with 40Ah batteries (*).
(*)60 A inverter, 6 meters travel, full charged batteries, new
and supplied by SMS.
The lift always works: in the event of a power
■ INSTALLATION CONDITIONS
failure at least 25 full travels are guaranteed
Operating temperature: -10 ÷ +50°C
Humidity: 0 ÷ 95%
(NO MORE walking up stairs !)
Max altitude 1000mt, over this height consider to derate the
There is no need to change the electricity supply
current of 1% every 100mt (max 3000mt).
contract: Hydrobatt requires at least 300W from
the mains (As a refrigerator !)
■ I/Os AND ADJUSTMENTS
Easy installation: it is applicable to any hydraulic
Run, high speed, safety chain control inputs, “ready to
work” and “battery on charge” relay outputs.
pump with external motor, also already installed.
Trimmer adjustments:
Easy start-up: no need for any adjustments or
Acceleration time : from 1 to 3 secs.
changes in the shaft, nor to the pump control unit
Deceleration time : from 0.5 to 2.5 sec.
(changing only the motor).
High speed : from 1500 to 3000 rpm
Soft start and stop driven by inverter.
Low speed : from 750 to 1500 rpm
Torque boost.
Reduction of the control panel components.
Diagnostics and operating LED signalling.
Compliance with standards: certified according to
EN 12015.
■ PROTECTIONS
Overcurrent, overload, average current, phase
unbalancement, battery voltage, contactors, maximum run
time.
■ OPTIONS
Supply of batteries from 26 Ah,40 Ah or higher if requested.
■ DIMENSIONS AND WEIGHTS
Box
SIZE (A)
Height (mm)
Width (mm)
Length (mm)
Weight (kg)
60
600
400
280
19
Motor
Height (mm)
Width (mm)
Length (mm)
Weight (kg)
Taylor Lifts – SMS Product Catalogue Issue 1
90
600
400
280
21
240
332
202
15
Was this manual useful for you? yes no