LPW8 Installation Instructions

LPW8 Installation Instructions
LPW8 SERIES INSTALLATION INSTRUCTIONS
Important
THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS.
SAVE THESE INSTRUCTIONS.
Warning
This product must be installed in accordance with National Electrical Codes and all other
local codes by a person familiar with the construction and operation of the product and
the hazards involved.
To prevent electrical shock, turn off the power during installation or maintenance.
To reduce the risk of fire, keep away from combustible materials.
Product
Overview
The LPW8 Series is an elegant, wallwash
fixture powered by COB LED technology.
Utilizing an asymmetric TIR optic, the LPW8
produces 2725 lumens (36 watts) of a
seamless and even wash of light for the most
demanding applications of museum and retail
lighting. The LPW8 Series features a
discreetly hidden integral driver which is
compatible with trailing edge electronic low
voltage dimmers (dimmable to 5%). Optional
addressing and control is available using
LumenTalk™ for ELV or 0-10V systems and
dimmable to 1%. COB LED panel is field
replaceable.
LPW8 Series Wall-Wash
See the fixture label for voltage and wattage
input.
Please consult our Product Catalog or web
site for available accessories.
We recommend that you first install the
reflector and any accessories before
installing the fixture.
Purpose
of This
Sheet
The purpose of this sheet is to provide step-by-step instructions to help you:
Dimming




Install accessory Gels
Install the fixture with any of the following: -00 fitting on an LSI track, -BUS fitting on an LSI
Busway, 5A canopy, -2G universal flange fitting, or -3G C-Clamp fitting
 Aim the self-locking fixture
 Service the 50,000 hour LED driver and LED board
The LPW8 is fully dimmable using compatible trailing-edge, low-voltage electronic dimmers.
Please review dimming application guide for detailed information and a list of compatible dimmers
www.LightingServicesInc.com
Page 1 of 6
IS-0226_A
Accessory Gel
Overview
The LPW8 series fixture features slots which will hold
several specially shaped Gel accessories for color or
beam spread.
STEP
Installing And
Removing Accessory
Gels
ACTION
1
Remove accessory Gel by inserting
finger into the hole at the top and
pulling on the Gel. (Fig. 1).
2
Insert the new Gel by aligning the
bottom edge in the groove and flexing
the gel (Fig. 2).
3
Insert the top of the Gel into the top
groove to hold it in place.
Figure 1. Remove accessory Gel by
inserting your thumb into the cutout and
pulling.
Figure 2. Insert accessory Gel by
inserting bottom edge, bending Gel, and
guiding it into the top groove.
www.LightingServicesInc.com
Page 2 of 6
IS-0226_A
Installing
the Fixture
with the
-00 Fitting
on an LSI
Track or a
-BUS
fitting on
an LSI
Busway
FOR USE WITH LSI 3, 4, 5, 6, 8, AND 9 SERIES TRACK
AND LSI 20 SERIES BUSWAY SYSTEMS ONLY.
INSTALLATION INSTRUCTIONS: The track or busway
must already be installed according to code requirements.
When installing or using this track or busway system, basic
safety precautions should always be followed, including the
following:
 Read all instructions.
 Do not install any part of a track or busway system less
than 5 feet above the floor (8 feet for 277 volt).
 Do not install any fixture closer than 6 inches from any
curtain or similar combustible material.
STEP
Figure 3. Fitting with switch OFF
and handle OPEN.
ACTION
1
Flip the fitting switch off and open the fitting handle
(Fig. 3).
2
Are you using a one-circuit or two-circuit system?
 If one-circuit, make sure the brass contacts that
Figure 4. Inserted fitting
protrude from the side of the fitting face the copper
busbars inside the track or busway.
 If two-circuit, inserting the fitting in one direction
connects to circuit one. Removing and reversing
the direction of the fitting connects to circuit two.
3
Insert the fitting straight up into the track or busway
until fully seated (Fig. 4).
4
Close the handle and flip the fitting switch on
(Fig. 5).
WARNING: Do not look directly at lit LED.
To remove the fitting, hold the fixture in place, flip
the fitting switch off, open the handle, and pull the
fitting straight off the track or busway.
5
Installing
the Fixture
with a 5A
Canopy
Figure 5. Switch ON, fitting handle
closed
Before Installing: Consult the code requirements for fixture
mounting. Mount the fixture to a ceiling constructed of noncombustible material, away from any flammable materials.
STEP
ACTION
1
Turn off all power to the fixture mount.
2
Unscrew the 2 supplied canopy mounting screws,
and remove the crossbar from the canopy
(Fig. 6).
3
Attach the canopy crossbar (Fig. 7) to a ceiling
junction box with 2 screws (supplied by others).
4
Fasten the power wires (Fig. 7) from the junction
box to the fixture wires.
Figure 6. Fixture mounted on the
5A Canopy
Note: Connect green to ground, black to the circuit
line, and white to neutral.
5
Attach the canopy to the ceiling with the 2 supplied
canopy mounting screws.
www.LightingServicesInc.com
Page 3 of 6
Figure 7. Ground and power wires
with canopy crossbar
IS-0226_A
Installing
the Fixture
with a -2G
Universal
Flange
Fitting or a
-3G
C-Clamp
Fitting
Before Installing: Consult the code requirements for fixture
mounting, and check the distance-from-wall label inside the
fixture. Mount away from any flammable materials.
For the -2G fitting, follow steps 1, 2, 4, and 5.
For the -3G fitting, follow steps 1, 3, 4, and 5.
STEP
ACTION
1
Turn off all power to the fixture.
2
Attach the -2G fitting (Fig. 8) to any noncombustible material, using the 2-hole flanged
mounting plate with 2 screws (supplied by
others) or bolt-up applications, such as Unistrut
or Kindorf systems.
3
Attach the -3G fitting (Fig. 9) to a noncombustible pipe measuring 5/8” to 2” in outside
diameter, and then secure the fitting by turning
the C-clamp bolt clockwise.
4
Figure 8. -2G universal flange
fitting
Figure 9. -3G C-clamp fitting
Plug the fixture into a power source.
IMPORTANT SAFETY INSTRUCTIONS
Never use with an extension cord unless the
plug can be fully inserted.
Do not alter the plug.
5
Turn on the main power, and then flip the fitting
switch on.
Note: The switch is located on the base of fitting.
www.LightingServicesInc.com
Page 4 of 6
IS-0226_A
Aiming the
SelfLocking
and
WrenchLocking
Fixtures
NOTE: Allen key storage is only on Track and
Busway Fittings.
STEP
1
ACTION
Turn off all power to the fixture,
including the fixture switch on the
fitting, and let the LED cool.
WARNING: LED and fixture may be
hot.
2
Do you want to aim the fixture
horizontally or vertically?
 For horizontal aiming, hold the
Fixture and turn it left or right until
you achieve your desired
orientation (Fig. 10).
Figure 10. Turn Fixture left or right to set the
horizontal focus.
 For vertical aiming, hold the Fixture
and angle it up and down until you
achieve your desired orientation
(Fig. 11).
Note: For track and busway fixtures,
the Allen key is stored in the fitting
handle (Fig. 12).
3
Restore power.
WARNING: Do not look directly at
the lit LEDs.
Figure 11. Angle Fixture up or down to set the
vertical focus.
Figure 12. Allen key storage in fitting.
Push in to secure the key.
www.LightingServicesInc.com
Page 5 of 6
IS-0226_A
Replacing
the LED
Module
If you need to change the LED Module or driver, follow the
steps below.
STEP
1
ACTION
Remove all power to the fixture, including the fixture
switch on the fitting, and let the LED Module cool.
WARNING: LED Module and fixture may be hot.
2
Remove the main accessory gel if present by inserting
your thumb in the hole and pulling. (Fig 1.)
3
Remove the two set screws holding the side plate in
place on the left side of the fixture. (Fig 13.) Set them
aside.
4
Once the set screws are out, remove the side plate.
Likewise remove the primary gels and set them aside,
noting orientation in the fixture. The gels have a shiny
side and a textured side. The shiny side should face the
LED board, the textured side out.
5
LED Replacement
Figure 13. Use the Allen wrench
to rotate the takedown nuts
down to remove side plate.
Remove the 6X screws holding the face plate over the
LED board. (Fig 14.) Set the screws and face plate
aside and lift the board clear of the fixture.
Driver Replacement
Remove the driver by pulling out the retaining clip and
then the driver itself. Use the quick connectors to
replace the driver electrical connections and re-install the
driver in the fixture using the retaining clip. (Fig 16.)
6
LED Replacement only: Cut the wires feeding the board
as close to the LED board as possible. Important: Note
the polarity of the wires for the next step. Remove the
old board by sliding it out the open side of the fixture.
(Fig 15.)
7
Insert the new LED board and reconnect the wires with
the same polarity as before.
8
Reinstall the face plate and secure it with the 6X screws
from step 5. (Fig 14.) Reinsert the primary gels, noting
orientation. Shiny side towards LEDs, textured side out.
9
Reinstall the side plate and secure it using the two set
screws from step 3. (Fig 13.)
10
Re-insert the main accessory gel if there is one by
aligning the bottom edge first and flexing the gel into
place. (Fig 2.)
11
Restore all power to the fixture.
WARNING: Do not look directly at the lit LED.
www.LightingServicesInc.com
Page 6 of 6
Figure 14. Remove the primary
gels, then remove the 6x screws
and face plate to access LED.
Figure 15. Slide the LED board
out the open side of the fixture.
Figure 16. A Quick Connector
with tab lifted. Please refer to
the label on the driver for wire
orientation.
IS-0226_A