Manual EN_M0092
43
81
119
157
M4
Troubleshooting
42
Certificate of compliance
DECLARATION OF CONFORMITY
The undersigned, representing the following manufacturer
Piusi S.p.A.
46029 – Suzzara (Mantova) - Italy
CERTIFIES
that the equipment described below:
Description:DISPENSING NOZZLE FOR FLUIDS
Model: K500
complies with the following directives:
2004/108/CE (Electromagnetic Compatibility Directive)
and following amendments
Suzzara 01.07.2009
President
C Using the manual.
ij The following symbols are used to highlight important notes and information:
This symbol highlights important aspects as to the
Warning
CORRECT USEof the METER.
Warning
This symbol highlights important aspects as to SAFETY.
Warning
This symbol highlights important aspects as to avoid
POLLUTION HAZARDS.
The instructions provided by this manual satisfy both the Installer's and the Users'
requirements (Manager and Operators) of the METER.
In the Table of Contents a symbol alongside each paragraph indicates the person this
information is intended for.
Operator
All paragraphs marked with this symbol concern the Operator. The
operator is the person who uses the METER to carry out dispensing
operations. Therefore the Operator is not expected to read paragraphs
other than those marked with this symbol.
All paragraphs marked with this symbol concern the Manager. The
Manager
Installer
6
selection of the Number of Decimal Digits, Calibration, etc.). At least
one skilled Operator (hereinafter referred to as the Manager) must
know this data in order to allow the Operators to use the METER
correctly. The Manager must read thoroughly all paragraphs
concerning the Manager and the Operator.
All paragraphs marked with this symbol concern the Installer only. He
is responsible for installing the METER and is required to read the
manual thoroughly, no paragraph omitted.
E. A large liquid-crystal display,
integrated in the 5-key keypad, for the
communication between the METER
and the Operator.
F. A motorized valve shutting system,
automatically activated by a
microprocessor when dispensing a
PRESELECTED amount (AUTO mode).
G. A multi-position extension to
adjust the angle of the dripless valve
with respect to the handle.
H. A dripless automatic valve.
D1 Detailed information on the METER
Handle
An external shock-resistant plastic cover contains all the
components of the METERand provides an ergonomic handle.
The battery pack
The battery pack is placed in the front
fixed
means of four cross-head screws.
The user can easily access this pack to
replace the batteries.
Swivel and filter
The METERis equipped with a swivel to
The swivel is equipped with a 1/2"
female thread (BPS or NPT) and houses
reduced pressure loss.
Rubber swivel cover
During installation the swivel may be
equipped with a rubber cover to
prevent the swivel itself or the metal
the vehicle body.
different
colours, which can be used as a "colour
code" to identify the dispensed product
easily.
8
Filter
Keypad
Meter
The keypad is of membrane type
and is equipped with 5 keys.
To guarantee an accurate measurement
of the dispensed amount the METER
uses the principle of the oval gears.
Multi-position extension
To guarantee an easy use, the METERis
equipped with a multi-position
extension. It can be positioned by the
operator within a 75° range.
Numeric keys:
to be used to set the PRESET value
(automatic dispense stop value).
AUTO key:
to be used to select and
PRESET value.
RESET key:
to be used to reset the Batch
Total and to display the
Resettable TOTAL.
.
Warning
During the operations necessary to
customize the METER, the keys
have extra functions, described in
paragraph G.
10
75°
30°
English
In addition the automatic
dripples valve can be
rotated of 240°.
30°
11
English
E2 Line pressure relief
This operation is to be carried out to
replace the pre-existing nozzle with the
METERnozzle or to dismount the
METERfor maintenance purposes.
Warning
Failure to carry out this line pressure
relief procedure may cause damage
to persons or things.
ij By means of two wrenches, unscrew
from the swivel.
ij Close the shut-off valve. Otherwise
stop the power supply pump and make
it unserviceable to avoid an accidental
re-start during maintenance operations.
ij Operate the valve of the nozzle to be
replaced (or of the METERto be
disassembled for maintenance reasons)
dispensing into a suitable container in
order to release the line pressure.
Warning
Be careful to collect any oil leakage
into a suitable container.
Warning
If a dripless valve is installed at the
end of the nozzle, the pressure inside
the line will not decrease to zero, but
it may stay at a value of 0.2 - 0.5 bar
according to the type of dripless
valve used.
ij (For the dismounting of the METER
only) Remove the rubber cover from its
coupling on the swivel and move it
flexible
easy access to the swivel.
15
E3 Flushing the lines
Flushing the lines means to let a given
amount of oil flow trough them so as
to ensure a proper "washing" of the
whole system, a correct cleaning and
the absence of dirt, contaminated
material or processed waste inside the
lines before installing the nozzle.
The flushing procedure depands on the
type and features of the system and
must be carried out by trained and
qualified personnel in compliance with
the procedures set down by the
installer.
Warning
The flushing operation must be carried
out on all lines, upstream the nozzle. In
case the system is equipped with more
than one nozzle, flush the lines which
supply the nozzles farthest away from
the supply the nozzles situated
nearer the pump.
This operation is absolutely
necessary with NEW INSTALLATIONS
or if the lines used are contaminated.
You need not carry out this
procedure when replacing the nozzle
in use.
E4 Preliminary checks of the METER
Make sure that the threaded end fitted
on the flexible hose is suitable for the
swivel of the METER provided with:
Female thread 1/2" BSP
or
Female thread 1/2" NPT
ij Check that the METERto be installed
is complete and in good condition,
making sure that the filter is clean and
correctly installed (see paragraph “H2”).
Filter
16
The filter of the METER, characterized by
a large filtering surface, has been
designed to guarantee a correct filtering
and a low pressure loss.
To remove and re-install the filter refer
to paragraph “H2”
Warning
The absence of the filter or its
improper installation may cause the
meter or the METER valve to block if
dirt is present in the tubes. This
situation may occur especially during
new installations.
To solve these problems consult a
qualified Service Centre
ff
can
be installed on the nozzle METER:
ij ADJUSTABLE extension;
ij RIGID extension;
ij FLEXIBLE extension.
All of them are equipped with an
automatic dripless valve.
All extensions are equipped with a rigid
ending part (external ? 12 mm, 3/8"G
nut) suitable for being easily connected
to the METERwithout using any sealant.
ij Remove the plug from outlet A (3/8”G).
ijœMake sure that gasket B on the
connector is in its seat.
ijœLubricate the gasket and its seat.
ij Tighten end D on METERby means of
two wrenches;
fi
METER, the second one tightens nut C
of end D.
Before locking nut C orientate valve E.
E
English
E5 Mounting the extension on the METER
D
C
B
A
Warning
An improper tightening of the
extension may cause it to become
loose thus endangering persons or
things.
Tighten the ring nut with a torque
wrench setting at 3.5 Kgm.
E6 Mounting the METER
ij Fit the rubber cover of the swivel into
fl
fi
over the male thread of the hose.
ij Apply a thread sealant to the male
fl
ij Tighten the swivel completely by
means of two wrenches.
ij Make the rubber cover slide towards
the valve until it goes into the specially
provided seat, located on the swivel.
17
ij To start dispensing:
Pull the trigger
completely and then
release it.
The trigger thus
remains locked in
open position. Now
dispensing can
continue even if the
Operator is not
present.
ij To stop manually dispensing in
progress:
Pull again the trigger completely and
then release it.
ij The dispensing operation can be
resumed in AUTO mode within a given
time (TIME OUT) from the stop. Within
this TIME OUT the METERstill allows the
locking of the trigger in open position.
ij After this TIME OUT the METERstill
allows the user to continue the
dispensing but only in MANUAL mode.
Manual resumption of the
dispensing (TOPPING UP):
Once dispensing has been carried out in
AUTO mode, the METERallows the user
to continue the dispensing operation, if
necessary.
Warning
Some time after the automatic stop of
dispensing, the METER2)
lights up and dispalys the preset
quantity and the value.
To carry out the TOPPING UP, DO
NOT type RESET and pull the trigger.
The dispensed amount is added to the
previous one in AUTO mode.
The PRESET value previously set,
displayed in the Total, starts blinking to
indicate that the pre-set value has been
exceeded.
Automatic stop:
The supply automatically stops when
the pre-set value is reached. The AUTO
message disappears from the LCD.
Blinking value.
23
English
Dispensing in AUTO mode.
To clean or replace the filter:
Warning
A. Release the line pressure and
dismount the METER in compliance
with the instructions given in paragraph
E2.
- Do not use filters which have
been damaged during improper
dismounting or cleaning
operations.
- Always reposition the filter with
the utmost care.
If the filter is in good condition
and is correctly installed, it
guarantees the good operation
of the METER, thus avoiding any
dust or foreign bodies, which
may lock or damage the METER
valve.
B. Unscrew the 1/2_ nut and remove
the filtering disk.
C. Properly clean the filter or use a
new filter (see Spare parts list in
paragraph M3).
D. Place the filter again, paying
attention to components’ positioning.
E. Reassemble the METER
according to the instructions given in
paragraph E6.
F. Fix the connection again and
tighten it at 20 Nm.
gasket
Nut
Nylon ring
L Product identification
Some technical data of
the METER, which is
essential for its safe
use, is indicated on the
CE plate located on the
right side of the handle.
36
MODEL METER
Max Work. Pres. 7000 KPa (1015 PSI)
Operating Temp. -5/+50°C (+23/+122 °F)
Min Flow Rate 1 L/m (0.26 gpm)
Max Flow Rate 30 L/m (7.9 gpm)
English
M Construction data
M1 Technical data
Measuring principle:
Oval gears
Flow range:
1 to 30* liter/min
0.26 to 7.9 gpm
Pressure range:
50* to 7000 KPa
7 to 1015 psi
Temperature range:
operating: -5 to + 50 °C
+23 to + 122 °F
storage: -35 to + 60 °C
-31 to + 140 °F
Viscosity range:
10 to 5000 mPa s
Accuracy:
+/- 0.5 % of indicated value
after on-site calibration.
Repeatability:
+/- 0.2 % of indicated value.
Resolution:
0.005
liter
0.0013 gallon
Pressure loss:
at 10 liter/min 80W oil at 21°C
2.6 gpm
80W oil at 70 °F
with HIGH FLOW spout: 150 KPa
22 psi
with DRIPLESSVALVE: 450 KPa
65 psi
Units of measurement:
Liter / Gallon / Pint / Quart
selectable by the operator.
Indications:
Batch Total:
0.000 to 999.9 units
Total/Resettable Total:999 999 units
Presettable amount:
0.1 to 99.9 units
Batteries:
4 x AA size 1.5 Volt
Expected life: 1 year
up to 10 000 AUTO operation
per year.
AUTO mode automatic inhibition
when "low battery" indication
is shown.
Inlet connection:
1/2" BSP female
1/2" NPT option
Weight:
batteries included
1,55 Kg
0,41 Ib
Fluid compatibility:
ij lubricating oils (mineral, synthetic)
ij antifreeze mixtures
Wetted parts:
ij Steel / stainless steel
ij Aluminium
ij Brass
ij Polyurethane
ij Acetalic resin
ij Nitrile rubber
* with HIGH FLOW spout
37
Position No.
1
2
3
4
5
6
7
8
Part description
Rubber protection
Filter unit
Locking ring
Battery pack
Batteries 1,5 V size AA
Articulated end
Display + board
Shell
Q.ty
1
1
1
1
4
1
1
2
Warning
When ordering spare parts, please always
specify:
- Position No. of spare part,
- Model,
- Serial No.
Serial number
39
English
M3 M3 Exploded drawing and Spare Parts List
M4 M4 Troubleshooting
FINDING
POSSIBLE CAUSE
pressure
High oil viscosity
Lack of accuracy Necessity to calibrate
the meter into the
(within few
percentage error)
Evident inaccuracy
The meter doesn’t
count.
LCD shadowed
LCD black
Impossible to
enter the AUTO
mode
condition
The feeding line has
not been purged from
the air
Counting system
malfunctioning
Counting system
malfunctioning.
The instrument has
been used too long
message “bAtt” ( see
par. H of the user
manual)
The batteries are
completely wear out
CORRECTIVE ACTION
the feeding lines from dirty
particles.(see par.E3 of the User
manual)
Use a pump able to create
higher pressure
If possible, keep the oil warmer
, in order to reduce viscosity.
Calibrate the instrument
following the instruction at par.
G7 of the User manual
Purge the lines ( see par. E7 of
the User manual)
Contact your dealer for repair
Contact your dealer for repair
Replace the battery.
Replace the battery.
Replace the battery.
the message “bAtt” ,
the dispensing in AUTO
mode is inaccessible
for safety reason ( see
par. H1 of the User
manual)
There is a problem on Contact your dealer for repair
the trigger locking
system
In AUTO mode,
the trigger doesn’t
remain in open
position
The trigger
compatible
doesn’t release
Use the instrument with the
The valve doesn’t work Contact your dealer for repair
40
FINDING
Leaking from the
non drip valve
Leaking from the
trigger
Leaking from the
swivel
Leaking from the
extension
The extension
nozzle
High wearing out
of the batteries.
POSSIBLE CAUSE
English
M4 M4 Troubleshooting
CORRECTIVE ACTION
Improper tight of the
valve nozzle
Once dismantled the extension
, check the tightness of the
valve nozzle.
If negative ,contact your dealer
for repair
Non drip valve doesn’t Once dismantled the extension
close correctly
,check the tightness of the
valve nozzle. If positive ,
replace the non drip valve.
The seals have been
Contact your dealer for repair
damaged
Verify the proper installation of
Improper hose
the hose
installation
Not compatible
Verify that the hose and the
threads
inlet swivel threads are the
same.
The installation of
Verify the presence of all the
the extension on the
component and the tightening
nozzle, has not been
of the nut (see par. E5 of the
made correctly
user manual)
The installation has not Verify that the elastic washer
been made correctly has been installed and the
tightening of the nut (see par.
E5 of the User manual)
Possible short circuit
Avoid to sprinkle water against
due to some water
the nozzle.
trapped into the
battery compartment
Possible short circuit
The instrument has been
due to humidity
designed to be used indoor. Do
into the battery
not use outdoor.
compartment
Battery installation and Verify that there is not any
contacts not correct.
short circuit on the battery
contacts
Electronic board
Contact your dealer for repair
malfunctioning.
Defective contact at
Disconnect the batteries and
the battery installation. wait for 30 seconds.
Start failing
after battery
replacement
DATA ERROR in the Defective board
display
Change the board
41
N N Disposal
The components must be given to companies that
specialise in the disposal and recycling of industrial waste
and, in particular, the DISPOSAL OF PACKAGING.
The packaging consists of biodegradable cardboard which
can be delivered to companies for normal recycling of
cellulose.
DISPOSAL OF METAL COMPONENTS
The metal components, both painted and stainless steel,
are usually recycled by companies that are specialised in
the metal-scrapping industry.
DISPOSAL OF ELECTRIC AND ELECTRONIC COMPONENTS:
these have to be disposed by companies that are
specialised in the disposal of electronic components, in
accordance with the instructions of 2002/96/EC (see text of
Directive below).
ENVIRONMENTAL INFORMATION FORCUSTOMERS IN THE
EUROPEAN UNION
European Directive 2002/96/EC requires that the
equipement bearing this symbol on the product and/or its
packaging must not be disposed of with unsorted
municipal waste. The symbol indicates that this product
should be disposed of separately from regular household
waste streams. It is your responsibility to dispose of this and
other electric and electronic equipment via designated
collection facilities appointed by the government or local
authorities.
DISPOSAL OF OTHERPARTS:
The disposal of other parts such as pipes, rubber seals,
plastic components and cables should be entrusted to
companies that special in the disposal of industrial waste.
42