ViewTech 180-VES-DMR-18S Technical Guide

ViewTech 180-VES-DMR-18S Technical Guide
DMR18S TECHNICAL MANUAL
2-wire Intercom System
CONTENTS
INTRODUCTION...........................................................................2
Installation Guide........................................................................2
CONFIGURATIONS......................................................................4
Debug State...............................................................................4
Work Mode.................................................................................8
Software Update........................................................................10
Tone Update..............................................................................10
RF CARD
UI Update...................................................................................11
Namelist Update.........................................................................12
by SD Card..............................................................................12
by DT-Config............................................................................13
Y
AS
2E
1
2
3
4
5
6
7
8
9
*
0
#
INTRODUCTIONS
Installation Guide
DESCRIPTION
Y
AS
2E
MOUNTING
As an upgrade of DMR18, DMR18s has more stable and stronger ability of communication. It achieves call model of 128 families, expands
capacity of the system. It also adds many special functions such as
select by touching keypad, namelist, voice prompt, etc. , which brings
clients fresh and modernized experience. And for convenience, users
can upgrade UI and Voice through SD card by themselves.
Surface mounting
1
2
3
Camera
angle
PARTS AND FUNCTIONS
Drill holes in the wall to match the size of
The view for rainy cover after mounted.
screws and attach the rainy cover to the wall.
Camera Lens
Night View LED
Speaker
LCD Screen
Touch Key
ID Card Window
Digital Keypad
4
5
6
350 mm
Adjustable Camera
Adjust the camera angle and attach the
metal to the panel and wire correctly.
Connectiong Port
RF CARD
3 2 1
1
4
2
3
5
6
7
8
9
*
0
#
Microphone
128 mm
Attach screws to fix the metal box
TERMINAL DESCRIPTION
1
2
1 47
L2
mm
Camera
angle
T/R - T/R+
CN-LK
Bus
3 2 1
JP-LK
42m
m
Drill a hole and attach the rainy
cover to it
4
•
•
•
•
3
395mm
+12V
EB+
EBN.O
LK+
LK-
L1
J/KMB
The last view for all mounting
Flush mounting
SD Card Slot
3 2 1
Attach the unit to the rainy cover correctlly
The view for rainy cover
after mounted
5
Adjust the camera angle and attach the
metal to the panel and wire correctly.
6
+12V: 12VDC power output.
LK-(GND): Power ground.
LK+(COM): Common contact of the relay .
NO.:Normally open contact of the relay(refer to DT technical
guide for detail informations about lock connection).
• EB+: Exit button connection port.
• EB-: Exit button connection port.
• JP-LK: For electronic lock safety type setting(refer to door
station lock connections).
• T/R-: USB-RS485 communication terminal negative.
• T/R+: USB-RS485 communication terminal positive.
• Bus(L1,L2): non-polarity bus line.
Attach screws to fix the metal
box
Attach the unit to the
rainy cover correctlly
Attach the baffle to protect
the unit from droping
7
RF CARD
The last view for all mounting
-2-
DMR18S Technical Menu
INTRODUCTIONS
Installation Guide
SYSTEM CONNECTION
Y
AS
2E
ELECTRIC LOCK CONNECTION
1) Door Lock Controlled with Internal Power
Code=29
OFF ON
DBC4A
Impedance
switch
Code=30
A B C D
Code=31
Code=28
1. The door lock is limited to 12Vdc, and holding current must be less
than 250mA when using internal power supply mode.
2. The Unlock Mode Parameter must be set to 0 (by default).
3. Jumper set to 1-2 position for power-off-to-unlock safety
type(Normally closed mode); set to 2-3 position for power-on-to -unlock type(Normally open mode ).
4. If different unlocking time is needed to be configured, change the
unlock time on door station,detail information refer to DT system technical guide .
Power-on-to-Unlock type:
Impedance
switch
+
Exit button
Code=4
12V 300mA
+12V
LK LK+
N.O.
EBEB+
-
12V 300mA
Code=5
Power-off-to-Unlock type:
OFF ON
DBC4A
Code=6
A B C D
Code=7
+12V
LK LK+
N.O.
EBEB+
+
Exit button
1 2 3
Jumper position in 2-3
Jumper position in 1-2
JP_LK
1 2 3
JP_LK
2) Door Lock Controlled with External Power
Impedance
switch
Code=1
OFF ON
DBC4A
Code=2
A B C D
Code=3
Code=0
AC~
100~240VAC
1. The external power supply must be used according to the lock.
2. The jumper must be taken off before connecting.
3. Setup the Unlock Mode Parameter for different lock types
• Power-on-to-unlock type:Unlock Mode=0(by default)
• Power-off-to-unlock type:Unlock Mode=1
4. If different unlocking time is needed to be configured, change the
unlock time on door station,detail information refer to DT system technical guide .
PC6
BUS(IM) BUS(DS)
Power-on-to-Unlock type:
+
-
+
Exit button
Take off the Jumper
Power-off-to-Unlock type:
Cut off the line
+12V
LK - (GND)
LK+(COM)
N.O.
EBEB+
1 2 3
JP_LK
+
-
+
Exit button
Take off the Jumper
Cut off the line
+12V
LK - (GND)
LK+(COM)
N.O.
EBEB+
1 2 3
JP_LK
RF CARD
1
4
2
3
5
6
7
8
9
*
0
#
• Note: The diagram take the monitor of DT47M for example.
DMR18S Technical Menu
SPECIFICATION
•
•
•
•
•
•
•
•
Power supply:
Camera Lens: Power consumption:
Screen:
Resolution:
Video signal:
Wiring:
Dimension:
DC24V
1/4 ACS 4T image sensor
Standby 33mA; Working status 157mA.
3.5 inch TFT
320(R, G, B)X240 pixels
CCIR/EIA optional
2 wires, non-polarity
350(H)×128(W)×46(D)mm
-3-
CONFIGURATIONS
Debug State
Descriptions:
DEBUG STATE
The Debug State is your starting point for using all the applications on
DMR18S.
>> Debug State <<
RF CARD
1
2
4
5
6
7
8
9
3
*
0
#
[9008]
0-#
Redial
1-#
Tools
2-#
Exits
Please Input Password
When door station is in
standby, press '#' key
Y
AS
2E
Input '9008', then input the
Admin Code.(66666666
by default)
1.ID Code: Select item 1 to enter ID Code setting page. You can input
0~3 to set as door 1 ~ door 4.
1. ID Code
[0]
[-]
(0~3)
* Cancel
Debug state menu is
launched
# Save
2.Unlock Timing: Select item 2 to enter Unlock Timing setting page,
setting range is from 01~99s.
2. Unlock Timing
[01]
[--]
Descriptions:
0-#: Call Monitor again
(01~99)
* Cancel
1-#: Go to Tools setting item
# Save
2-#: Exit out Debug State
3.Unlock Output: Select item 3 to enter Unlock Output setting page.
TALK VOLUME ADJUST
0 : Power-on-to-unlock mode
In Debug State, calling the monitor and conversation are available,
you can input 0~9 to select the volume you want, see the following
picture shows.
1 : Power-off-to-unlock mode
3. Unlock Output
[0]
[-]
(0~1)
* Cancel
# Save
4.Monitor Timing: Select item 4 to enter Monitor Timing setting
page .the setting range is from 006~600s.
INSTALLER SETUP
4. Monitor Timing
[600]
[---]
>> Debug State <<
0-#
1-#
2-#
Redial
Tools
2.Setup
Tools
Exits
During working at debug
state,press "1#" to enter
tools page.
1.Installer Setup
3.Card Manage
Pres NO.
to select
4.Online Monitors
*Back
6.Voltage Measure
Installer
Setup
Press No.
to select
5.Online Devices
Press NO.“1” to enter
Installer setup item.
*Back
1. ID Code
[0]
2. Unlock Timing [01]
3. Unlock Output
[0]
4. Monitor Timing [600]
5. Doorplate Mode [0]
6. Waiting Timing [040]
7. Talking Timing [090]
8. Installer Code ...
9. Default ...
Installer setup page
overview.
(0~3)
* Cancel
# Save
5.Doorplate Mode: Select item 5 to enter Doorplate Mode setting
page.
0 : Input room number to call monitor
1 : Input room number + ‘#’ to call monitor
* Note:
1) the diagram take “0” mode for example.
2) Disable input 1 digit number to call
-4-
DMR18S Technical Menu
CONFIGURATIONS
Debug State
5. Doorplate Mode
[0]
[-]
5. Doorplate Mode
# Save
9.Default: Select item 9 to enter Default setting page. Input the setup
code to restore factory setting.
[::::::::]
Input 0
0: *
1: 123
2: ABC
3: -
(0~1)
* Cancel
[11]
Y
AS
2E
* Cancel
9. Default ...
[--------]
# Save
Please input password
Set 2 digit
number calling
5. Doorplate Mode
* Cancel
# Save
[11]
[ * * * * * *1 1 ]
SETUP
0: *
1: 123
2: ABC
3: * Cancel
# Save
>> Debug State <<
0-#
Redial
1-#
Tools
2-#
Tools
[040]
[---]
Setup
2.Setup
3.Card Manage
Exits
6.Waiting Timing: Select item 6 to enter Waiting Timing setting
page.The setting range is from 006~600s.
6.Waiting Timing
1.Installer Setup
During working at debug
state,press "1#" to enter
tools page.
Pres NO.
to select
4.Online Monitors
*Back
6.Voltage Measure
Press No.
to select
5.Online Devices
Press NO.“2” to enter
Setup item.
*Back
1. Language
[0]
2. Tone Select
[01]
3. Tone Volume
[3]
4. Unlock Code [1111]
5. Work Mode
[0]
6. Clock ...
7. Setup Code ...
8. About ...
9. Default ...
Setup page overview.
(006~600)
* Cancel
# Save
Descriptions:
1.Language: Select item 1 to enter Language setting page. Select
the language you need.(Refer to the following UI Update section).
7.Talking Timing: Select item 7 to enter Talking Timing setting page.
The setting range is from 006~600s.
1. Language
00
7. Talking Timing
[0]
English
[090]
[---]
* Cancel
# Save
(006~600)
* Cancel
# Save
8.Installer Code: Select item 8 to enter Installer Code setting page.
(Setting 8 digit numbers).
8. Installer Code ...
2.Tone Select: Select item 2 to enter Tone Select setting page. Select
the Tone you want. (Refer to the following Tone Update section).
2. Tone Select
[01]
00
Mute
01
Tune
02
English
* Cancel
# Save
[--------]
(********)
* Cancel
# Save
3.Tone Volume: Select item 3 to enter Tone Volume setting page.
The setting range is 0 ~ 9.
3. Tone Volume
[3]
[-]
(0~9)
* Cancel
DMR18S Technical Menu
# Save
-5-
CONFIGURATIONS
Debug State
4.Unlock Code: Select item 4 to enter Unlock Code setting page.
1111 is the default unlock code. Input 4 digit numbers to set a new
code(Except for 8001~8019 and 9008).
4. Unlock Code
8.About: Select item 8 to enter About page. The information includes
Hardware version, Software Version etc.
Hardware Version
DMR18S-CT a1.1
Software Version
V000101
Manufacture Date
2015-06-22
Dailing Count[0006]
Calling Count[0002]
Unlock Count[0005]
[1111]
[---]
(***)
* Cancel
Y
AS
2E
* Cancel
# Save
5.Work Mode: Select item 5 to enter Work Mode setting page. four
modes can be available,the setting range is 0~3.(More details refer to
the following Work Mode section)
# Save
9.Default: Select item 9 to enter Default setting page. Input setup
code to restore factory settings.
9. Default ...
0 : 32 apartments
[--------]
1 : 128 apartments
Please input password
2 : Router
* Cancel
# Save
3: Gateway
5. Work Mode
[0]
[-]
CARD MANAGE
(0~3)
* Cancel
>> Debug State <<
# Save
6.Clock: Select item 6 to enter Clock setting page.
0-#
Redial
1-#
Tools
2-#
Tools
1.Installer Setup
Card
Memory
2.Setup
3.Card Manage
Exits
Press No.
to select
Pres NO.
to select
4.Online Monitors
*Back
6.Voltage Measure
5.Online Devices
1. Add Card ...
2. Delete By Card
3. Delete By M.code
4. Cards Information
5. Format
*Back
6. Clock ...
6. Clock ...
Input 0
[-]
[-]
0: DD/MM/YY
0: 24-Hour
1: MM/DD/YY
1: 12-Hour
* Cancel
* Cancel
# Save
During working at debug
state,press "1#" to enter
tools page.
16/07/15
4 14/13
Input time
1.Add Card: Select item 1 to enter Add Card setting page.
6. Clock ...
1. Add Card ...
--/--/--
-
1. Add Card ...
--/--
Input 001
[---]
DD/MM/YY W
HH/MM
Card Manage page
overview.
# Save
Input 0
6. Clock ...
Press NO.“3” to enter
Card Manage item.
[001]
DD/MM/YY W HH/MM
Please input room code
* Cancel
# Save
* Cancel
Show the card
# Save
* Cancel
* Note: the diagram take “0” mode for example.
7.Setup Code: Select item 7 to enter Setup Code setting page. Input
8 digit numbers to set a new setup code, then press ‘#’ to save.
# Save
* Cancel
# Save
Show the card
1. Add Card ...
[001]
i Updated
Card Numbs.05410469
7. Setup Code ...
* Cancel
[ - - - - - - - -]
# Save
(********)
* Cancel
-6-
# Save
DMR18S Technical Menu
CONFIGURATIONS
Debug State
2.Delete Card:
Y
AS
2E
ONLINE MONITORS
• Select item 2 to Delete By Card.
To search the Gateway and Online Monitors,input the monitor code
number to search.
2. Delete By Card
2. Delete By Card
>> Debug State <<
i Updated
Show The Card
Card numbs:15977131
# Save
* Cancel
# Save
Redial
1-#
Tools
2-#
Exits
4. Online Monitors
Tools
1.Installer Setup
2.Setup
3.Card Manage
Pres NO.
to select
4.Online Monitors
*Back
6.Voltage Measure
Gateway:[ ]
IM:[ ] ~ [ ]
(Search Range)
5.Online Devices
* Cancel
# Save
Us
C a er
rd
* Cancel
0-#
During working at debug
state,press "1#" to enter
tools page.
• Select item 3 to Delete By M.code.
3. Delete By M.code
Press NO.“4” to enter
Online Monitors item.
Input the search
range,then press “#”
to start search.
3. Delete By M.code
[---]
[001]
i Updated
Please Input Room Code
Please Input Room Code
* Cancel
# Save
* Cancel
ONLINE DEVICES
# Save
To search the online door stations(Max.4 door station can be
searched) and the other accessories.
>> Debug State <<
0-#
Redial
1-#
Tools
2-#
Exits
3.Card Information: Select item 4 to enter Card Information
page,the card count will be showed.
During working at debug
state,press "1#" to enter
tools page.
4. Cards Information
5. Online Devices
Tools
1.Installer Setup
2.Setup
3.Card Manage
Pres NO.
to select
4.Online Monitors
*Back
6.Voltage Measure
5.Online Devices
Press NO.“5” to enter
Online Devices item.
[CDS1]: Online
[CDS2]: Online
[CDS3]: Fail
[CDS4]: Fail
* Cancel
# Save
All devices online or
offline will be showed.
Card Count: 320
* Cancel
# Save
VOLTAGE MEASURE
4.Format: Select item 5 to enter Format page.Input 8 digits password to start format.
To check the voltage of the monitor,note that the monitor must be
online.
>> Debug State <<
5. Format
5. Format
[--------]
[ 66666666 ]
0-#
Redial
1-#
Tools
2-#
Exits
i Updated
Please Input Password
* Cancel
# Save
1.Installer Setup
[--]
2.Setup
3.Card Manage
Pres NO.
to select
4.Online Monitors
*Back
6.Voltage Measure
5.Online Devices
* Cancel
# Save
Please Input Password
* Cancel
# Save
During working at debug
state,press "1#" to enter
tools page.
DMR18S Technical Menu
6. Voltage Measure
Tools
Press NO.“6” to enter
Card Manage item.
Input the code,then press
“#” to search.
-7-
CONFIGURATIONS
Work Mode
DEFINITION
Y
AS
2E
DT-DJ MODE
Total four different work modes are available for DMR18S to accommodate different situation. In standby mode, input #8002 + code
(66666666) and select “ 5 ” item to enter Work Mode setting page.
Setup
RF CARD
1
4
2
3
5
6
7
8
9
*
0
#
[ 8002 ]
Please Input Password
Press No.
to select
*Back
1. Language
[0]
2. Tone Select
[01]
3. Tone Volume
[3]
4. Unlock Code [1111]
5. Work Mode
[0]
6. Clock ...
7. Setup Code ...
8. About ...
9. Default ...
Work Mode set to 1:
The DT-DJ Mode is used for the audio intercom system. When the
system contains of the audio monitors, such as DJ4A, DJ5A, DJ6A,
etc. The DT-DJ Mode can be assigned the address from 001 to 128
without BDU unit.
Work Mode set to 1, and ID code set to 0~3.
5. Work Mode
[0]
[1]
When door station is in
standby, press '#' key
Input '8002', then input the
Admin Code.(66666666
by default)
Select “5” to enter
Work Mode page.
(0~3)
* Cancel
# Save
STANDARD 32 APARTMENTS
1. ID Code
Work Mode set to 0;
[0]
[0]
The Standard Mode is applied in a small capacity system, which
monitors are under 32 and without BDU unit. Generally dial 01~32 to
call the monitor.
(0~3)
* Cancel
# Save
Work Mode set to 0, and ID code set to 0~3.
5. Work Mode
[0]
1. ID Code
[0]
[0]
[0]
(0~3)
(0~3)
* Cancel
# Save
* Cancel
Input Mode: In standby mode. Input #8001+ Code ( 66666666 by
default), then select “ 5 ” item to set the Doorplate Mode, for example
input the code 068 to call the monitor.
# Save
5. Doorplate Mode
[111]
[*****111]
Input Mode: In standby mode. Input #8001+ Code( 66666666 by
default), then select “ 5 ” item to set the Doorplate Mode, for example
input the code 15 to call the monitor.
5. Doorplate Mode
0: *
1: 123
2: ABC
3: * Cancel
# Save
[11]
[ * * * * * *1 1 ]
0: *
1: 123
2: ABC
3: * Cancel
-8-
# Save
DMR18S Technical Menu
CONFIGURATIONS
Work Mode
DT-BDU ROUTER MODE
Y
AS
2E
DT-BDU GATEWAY MODE
The Router Mode is used for the big capacity system which has plenty of apartments for blocks with BDU unit. The namelist can be updated by SD Card or DT-Config (More details refer to Update Namelist
Section).
The Gateway Mode is used for the community network system, the
common door station is connected in the system which can call all the
monitors. Besides, if the door station is connected in each block,it can
call the monitors in the block.
Work Mode Set to 2, and ID code set to 0~3.
Work Mode set to 3, and ID code set to 0~3.
5. Work Mode
[0]
5. Work Mode
[2]
[3]
(0~3)
* Cancel
(0~3)
# Save
1. ID Code
[0]
* Cancel
# Save
[0]
1. ID Code
[0]
[0]
[0]
(0~3)
* Cancel
(0~3)
# Save
* Cancel
Input Mode: In standby mode. Input #8001+ Code ( 66666666 by
default), then select “ 5 ” item to set the Doorplate Mode, for example input 13-02 to call the monitor. As the following picture shows: 13
means the 13th floor, and 02 means the second room numbe.
5. Doorplate Mode
Input Mode: In standby mode. Input #8001+ Code ( 66666666 by
default), then select “ 5 ” item to set the Doorplate Mode, for example
input 3-06 to call the monitor. As the following picture shows: 3 means
the third BDU, and 06 means the ID code of monitor is 06.
[11]
5. Doorplate Mode
[***11-11]
0: *
1: 123
2: ABC
3: -
# Save
* Cancel
DMR18S Technical Menu
[11]
[****1-11]
0: *
1: 123
2: ABC
3: * Cancel
# Save
# Save
-9-
CONFIGURATIONS
System Update
Y
AS
2E
5. Insert the SD card to slot, the information of “Download...” will be
showed when the updated is in progress. After 3 seconds, a long
sound “BP+” will be heard to start the updated.
DESCRIPTIONS
This section is used for the software version V000101 of DMR18S.
(After 2015.07.10); In standby mode, please input “#+#” to check the
DMR18S software version, see the following picture shows:
How to enter update page:
RF CARD
1
4
2
3
5
6
7
8
9
*
0
#
[ 8014 ]
Please Input Password
6. When update is finished, it will return to Standby Mode interface.
When door station is in
standby, press '#' key
Input '8014', then input the
Code 87625761
Update setting page
overview
SOFTWARE UPDATE
1. Format SD card
2. Copy the update software file( DMR18S.bin,provided by our
company ) to SD card by computer.
TONE UPDATE
1. Format SD card
2. About the Ringtone file
• English is the standard audio file, as the picture shows:
4. Select 1 to enter Firmware update, the information of “update
ready” will be showed.
-10-
DMR18S Technical Menu
CONFIGURATIONS
System Update
• If other languages are needed for you, please record the audio file
which language you want.
Y
AS
2E
7. Check the Tone
Setup
• Then provide the audio file to our company, a Ring.bin file will be
created for you to update the tone.
Press No.
to select
*Back
1. Language
[0]
2. Tone Select
[01]
3. Tone Volume
[3]
4. Unlock Code [1111]
5. Work Mode
[0]
6. Clock ...
7. Setup Code ...
8. About ...
9. Default ...
2. Tone Select
00
Mute
01
Tune
02
English
* Cancel
[01]
# Save
3. Copy the Ring.bin file to SD card by computer.
When door station
is in standby, press
'#8002'+code 66666666
to enter Setup page.
select item 2 to enter
Tone Select setting
page.
Select 02(English) to
check your tone update,
and press # to save.
UI UPDATE
4. Select 2 (Voice update) to enter Tone update,the information of
“update ready” will be showed.
1. Format SD card
2. Edit UI file
Multi languages are supported on DMR18S, English is the standard
language, if other languages are needed for you, please provide the
translation to us. About the UI file, see the following picture shows:
5. Insert the SD card to slot, the information of “Download...” will be
showed when the updated is in progress. After 3 seconds, a long
sound “BP+” will be heard to start the updated.
6. When update is finished, it will return to Standby Mode interface.
DMR18S Technical Menu
-11-
CONFIGURATIONS
System Update
3. Copy the Update UI file to SD card by computer.
4. Select 3 to enter UI update,the information of “update ready” will
be showed.
Y
AS
2E
6. When update is finished, it will return to Standby Mode interface.
And show the new UI.
NAMELIST UPDATE
1) Namelist update by SD card
1. Format SD card
2. Namelist.txt file setting
• Create a TXT file, and named NameList.
5. Insert SD card to slot, after that, the update progress will be
showed.
• Open the NameList.txt file, and input 5 [ ] symbols. Each [ ]
symbol has its meaning, see the following picture.
Descriptions:
Input: Input the number to call the monitor
Name: It would be displayed on screen
font.bin
:12%
Gateway: Set the gateway mode recording to BDU address.
[08~15] means BDU address 01~08
Router: Set the Router mode recording to BDU address. [01~08]
means BDU address 01~08
Address: Set the monitor address you want to call
• Edit NameList.txt file, for example, as the following picture shows:
font.bin
:100%
image.idx
:100%
image.bin
:6%
Input 101 or 1-01, it would call the monitor 01 in BDU 1.
-12-
DMR18S Technical Menu
CONFIGURATIONS
System Update
3. Copy the Namelist file to SD card by computer.
Y
AS
2E
2) Namelist update by DT-Config
DMR18S-Config software is for parameters setting, namelist setting
etc. It is great convenience to installation.
The DMR18S-Config software operation is as follows:
1. Open “DMR18S-Config” software,connnect DMR18S to PC via
USB-RS-485;Click “Setting” on the menu bar then click Com to select
right Com.(Com information can be found in “ My Computer -> Properties ->Device Manage->Ports”)
4. Select 4 to enter Namelist update,the information of “update
ready” will be showed.
5. Insert the SD card to slot, the information of “Download...” will be
showed when the updated is in progress. After 3 seconds, a long
sound “BP+” will be heard to start the updated.
2. Then if DMR18s is connected to PC successfully, one tips of “Device
connected” will be showed. Click “Room Table” tab to edit Name list.)
6. When update is finished, it will return to Standby Mode interface.
3. Then click “Insert” to create the first item.
7. Press
touch button to show the Name list
Each item have 5 different properties:
Address: Monitor’s address (can be find in “about”);
User Code: The number you can dial to the monitor;
Name: The name of resident;
Router: Set the BDU address when it is in Router mode;
Gateway: Set the BDU address when it is in Gateway Mode.
DMR18S Technical Menu
-13-
CONFIGURATIONS
System Update
Y
AS
2E
• Check Name List on DMR18S
Set the DMR18S Work Mode as 0 (more details refer to Work Mode
setting section).
• Press
touch button to enter Name List page. See the following
picture shows.
4. Edit Namelist
4.1 Apartments
• For example: Dial 101 to call the Apartment 01 without BDU. See
the following picture shows:
4.2 Router
• Input 01-01 to call the monitor 01 in the BDU 1 when it is in
Router mode,And input 02-02 to call the monitor 02 in the BDU 2
when it is in Router mode, see the following picture:
• After edited, click “Download Table” to download Name List to
DMR18S; After a few seconds, a window will be displayed if it is
updated successfully.
• Click Download Room Table to download the namelist.
-14-
DMR18S Technical Menu
CONFIGURATIONS
System Update
• Check Name List on DMR18S
Y
AS
2E
• Check Name List on DMR18S
Set the DMR18S Work Mode as 2 (more details refer to Work Mode
setting section).
Set the DMR18S Work Mode as3 (more details refer to Work Mode
setting section).
• Press
touch button to enter Name List page. See the following
picture shows.
• Press
touch button to enter Name List page. See the following
picture shows.
4.3 Gateway
• Input 1-01 to call the monitor 01 in the BDU 1 when it is in
Gateway mode,And input 2-02 to call the monitor 02 in the
BDU 2 when it is in Gateway mode, see the following picture:
• Click Download Room Table to download the namelist.
DMR18S Technical Menu
-15-
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising