ISO 9001 Certified
The Hanna line of controllers have been designed to
give outstanding performance with the latest innovative
technology. Hanna controllers are precise, rugged,
easy-to-use, economical and reliable.
ISO 9001 Certified
Panel Mount
pH, ORP & Conductivity
Controllers
Panel Mounted
Controllers
...technical superiority.
General dimensions panel mounted controllers:
Front view of the panel-mounted indicator. Dimensions show the cutout size for installation and also the outside dimensions of the indicator panel.
TECHNICAL SUPERIORITY
Hanna panel mount pH, ORP and Conductivity
controllers are designed to meet your most
demanding process control requirements.
Standard features include calibration and self
diagnostic from the front panel touch pad,
4-20 mA output, 2 amp 240 volt dry-contact
control relay (controllers only) and a large LCD
display. When applications require a long
distance between the sensor and controller, a
controller with a 4-20 mA input from a
transmitter is available.
The controllers utilize a sophisticated built in
self-diagnostic function that allows operators
to check whether a malfunction originated
in the controller or from an outside connection.
This unique self-diagnosis system saves
troubleshooting time and costly process
interruptions.
ALARM FEATURES
Hanna controllers incorporate an additional 2
amp 240 volt dry contact relay to provide alarm
warning capabilities. When the solution being
monitored passes the setpoint value of the
control relay, this second relay will trigger and
activate a customer supplied device such as an
alarm, light or a process emergency shut down
Hanna Instruments
contact. The alarm feature is necessary when an
installation is in a remote location and corrective
action must be taken immediately.
RECORDER OUTPUT
The ability to record data from the process you
are monitoring greatly enhances process
troubleshooting. By simply connecting a recorder
to the controller's output terminals (choose
between 0 to 20 mA or 4 to 20 mA according to
your needs), you are able to acquire a hard copy
for demonstrative or analytical purposes.
LOW OR HIGH IMPEDANCE INPUT
Hanna’s pH and ORP controllers come in two
different models to meet all requirements. The
“E” model, has a high impedance 1012 Ohm
direct input from an electrode. Ideal for connections with a distance of up to 33 feet (10
meters). The “T” model, however, is recommended for distances greater than 33 feet (10
meters) and should be used with a 4 to 20 mA
transmitter. The greater the distance between the
controller and the sample, the greater the chance
you have of line noise causing erroneous
readings. Using a transmitter greatly enhances
the input signal, thus allowing high accuracy at
distances of up to 1000 feet (300 meters).
CONSENT FEATURE
The consent contact allows you to be sure that
the ORP dosing occurs only when the pH value
is correct. This assures that the pH is within a
specified range before any dosing of oxidizing or
reducing agents occurs. This will prevent any
overdosing of chemicals, a very important
cost-effective feature in many applications,
especially in pools, spas and hot tubs.
QUALITY CONSTRUCTION
The controller electronics are held in a sturdy
aluminum housing with a shock resistant ABS
plastic front control panel. All controllers come
complete with easy-to-install mounting brackets
and a transparent protective front panel cover.
LED INDICATORS
The LEDs on the front panel light up to indicate
the correct operational mode. The LEDs also
blink at different rates to indicate multiple modes
occurring simultaneously. This feature allows
the user to evaluate the controller from a
distance and clearly read which mode it is in.
Water Analysis & Control Division
HI 8500 Series
...accurate monitoring of pH and ORP.
HI 8510
Panel Mounted pH
Indicator
•
•
•
•
•
•
•
•
Ideal for constant monitoring of pH in industrial
process control.
Accurate measurements from 0.00 to 14.00 pH
with a 0.01 resolution displayed on a large,
easy-to-read LCD.
Designed with DIN standard panel-mount for
easy installation (mounting brackets are also
included).
A unique auto-diagnostic test can be performed
to check the pH electrode and instrument status.
Two models are available, one with direct input
from a pH electrode (“E” type) and another
for a 2-wire current loop of 4 to 20 mA from a
pH transmitter (“T” type).
Isolated recorder output in either 0 to 20 mA
configuration or 4 to 20 mA.
LED indicators positively identify operational
mode.
Protected behind a removable splash-proof
transparent cover.
SPECIFICATIONS
Model
HI 8510E
Range
0.00 to 14.00 pH
Resolution
0.01 pH
Accuracy (@20°C/68°F) ±0.02 pH
Typical EMC Deviation ±0.1 pH
Input
High Impedance 1012 ohm
Calibration
Offset: ±2 pH by ∆O trimmer /
Slope: 80 to 110% by slope
trimmer
Temp. Comp.
Fixed or automatic with Pt100
from 0 to 100°C (32 to 212°C)
Readout
4-digit LCD plus graphic symbols
Recorder Output
0 to 20 mA (HI 8510E020) or
4 to 20 mA (HI 8510E420)
(isolated)
Power Supply
110/115V or 220/240V; 50/60 Hz
Enclosure
DIN 43 700 144 x 72 mm
(5.67 x 2.83”) in black anodized
aluminum. Front and back with
shockproof ABS plastic and
transparent cover.
Environment
14 to 122°F (-10 to 50°C);
RH 95% non-condensing
Weight/Panel Cutout
2.2 lb. (1 Kg )/5.55 x 2.71”
(141 x 69 mm)
Accessories for HI 8510E
HI 1002/5
pH electrode with 16.5’ (5 m) cable
HI 5001/5
Stainless steel Pt100 probe
HI 7004L
pH 4.01 buffer solution (500 mL)
HI 7007L
pH 7.01 buffer solution (500 mL)
HI 7010L
pH 10.01 buffer solution (500 mL)
HI 8427
pH and ORP electrode simulator
HI 931001 pH and ORP electrode simulator
Hanna Instruments
HI 8512
SPECIFICATIONS
Panel Mounted ORP
Indicator
•
•
•
•
•
•
•
•
•
Provides constant monitoring of ORP in process
control.
Easy to install DIN standard panel-mount with
mounting brackets included.
LED indicators display operational mode.
Measures ORP from -1000 to +1000 mV.
Built-in auto-diagnostic tests check the
indicator's status with LED indicators.
Two models are available, one with direct input
from an ORP electrode (“E” type) and another
for a 2-wire current loop of 4 to 20 mA from
an ORP transmitter (“T” type).
Isolated recorder output in either 0 to 20 mA
configuration or 4 to 20 mA.
Splash-proof transparent cover protects the
keyboard from liquids.
The body is constructed of Aluminum. The
front is made of rugged ABS for maximum
strength.
Accessories for HI 8512E
HI 2002/5 ORP Pt electrode with 16.5’ (5 m) cable
HI 7020L
ORP testing sol. 200/275 mV (500 mL)
HI 7091L
Reducing solution (500 mL)
Model
Range
Resolution
Accuracy (@20°C/68°F)
Typical EMC Deviation
Input
Calibration
Readout
Recorder Output
Power Supply
Enclosure
Environment
Weight/Panel Cutout
HI 7092L
HI 8427
HI 931001
HI 8512E
-1000 to 1000 mV
1 mV
±5 mV
±6 mV
High Impedance 1012 ohm
Slope: 90 to 110% by
slope trimmer
4-digit LCD plus graphic symbols
0 to 20 mA (HI 8512E020) or
4 to 20 mA (HI 8512E420)
(isolated)
110/115V or 220/240V; 50/60 Hz
DIN 43 700 144 x 72 mm
(5.67 x 2.83”) in black
anodized aluminum. Front and
back with shockproof ABS
plastic and transparent cover.
14 to 122°F (-10 to 50°C);
RH 95% non-condensing
2.2 lb. (1 Kg )/5.55 x 2.71”
(141 x 69 mm)
Oxidizing solution (500 mL)
pH and ORP electrode simulator
pH and ORP electrode simulator
Water Analysis & Control Division
HI 8700 Series
...excellence in pH control.
HI 8710
Panel Mounted pH
Controller
•
•
•
•
•
•
Single set point version with selection of acid or
alkaline dosage.
The alarm band is user-selectable from 0.1 to 3
pH and will be activated when the pH level
deviates from the set point by more than the
selected alarm value.
When used in conjunction with the HI 8720
ORP controller, ODCD** ensures that ORP
dosage will only start when the pH is at the
correct level.
Two models are available, one with direct input
from a pH electrode (“E” type) and another
for a 2-wire current loop of 4 to 20 mA from a
pH transmitter (“T” type).
Isolated recorder output in either 0 to 20 mA
configuration or 4 to 20 mA.
Sophisticated auto-diagnostic functions make it
easy to check and troubleshoot malfunctions
from the front panel.
SPECIFICATIONS
Model
HI 8710E
Range
0.00 to 14.00 pH
Resolution
0.01 pH
Accuracy (@20°C/68°F) ±0.02 pH
Typical EMC Deviation ±0.1 pH
Input
High Impedance 1012 ohm
Calibration
Offset: ±2 pH by ∆O trimmer /
Slope: 80 to 110% by slope
trimmer
Temp. Comp.
Fixed or automatic with Pt100
from 0 to 100°C (32 to 212°F)
Readout
4-digit LCD plus graphic symbols
Recorder Output
0 to 20 mA (HI 8710E020) or
4 to 20 mA (HI 8710E420)
(isolated)
Setpoint Relay/
One, isolated, 2 A, Max. 240V,
Alarm Relay
resistive load, 1,000,000
strokes
Power Supply
110/115V or 220/240V; 50/60 Hz
Enclosure
DIN 43 700 144 x 72 mm
(5.67 x 2.83”) in black anodized
aluminum. Front and back with
shockproof ABS plastic and
transparent cover.
Environment
14 to 122°F (-10 to 50°C);
RH 95% non-condensing
Weight/Panel Cutout
2.2 lb. (1 Kg )/5.55 x 2.71”
(141 x 69 mm)
Accessories for HI 8710E & HI 8711E
HI 1002/5
pH electrode with 16.5’ (5 m) cable
HI 5001/5
Stainless steel Pt100 probe
Hanna Instruments
HI 8711
Panel Mounted pH
Controller
•
•
•
•
•
•
Dual set point with 2 independent dosing
outputs, one for acid and another for alkaline
dosage.
Auto-diagnostic feature is incorporated to verify
offset and slope calibration as well as electrode
contamination/deterioration.
The alarm band is user selectable from 0.1 to 3
pH and will be activated when the pH level
deviates from the set point by more than the
selected alarm value.
When used in conjunction with the HI 8720
ORP controller, ODCD** ensures that ORP
dosage will only start when the pH is at the
correct level.
Two models are available, one with direct input
from a pH electrode (“E” type) and another
for a 2-wire current loop of 4 to 20 mA from a
pH transmitter (“T” type).
Isolated recorder output in either 0 to 20 mA
configuration or 4-20 mA.
Splash proof transparent cover protects the
controls of the instrument from liquids.
HI 7004L
HI 7007L
HI 7010L
pH 4.01 buffer solution (500 mL)
pH 7.01 buffer solution (500 mL)
pH 10.01 buffer solution (500 mL)
SPECIFICATIONS
Model
HI 8711E
Range
0.00 to 14.00 pH
Resolution
0.01 pH
Accuracy (@20°C/68°F) ±0.02 pH
Typical EMC Deviation ±0.1 pH
Input
High Impedance 1012 ohm
Calibration
Offset: ±2 pH by ∆O trimmer /
Slope: 80 to 110% by slope
trimmer
Temp. Comp.
Fixed or automatic with Pt100
from 0 to 100°C (32 to 212°F)
Readout
4-digit LCD with graphic symbols
Recorder Output
0 to 20 mA (HI 8711E020) or
4 to 20 mA (HI 8711E420)
(isolated)
Setpoint Relay
Two, isolated, 2 A, Max. 240V,
resistive load, 1,000,000 strokes
Alarm Relay
One, isolated, 2 A, Max. 240V,
resistive load, 1,000,000 strokes
Power Supply
110/115V or 220/240V; 50/60 Hz
Enclosure
DIN 43 700 144 x 72 mm
(5.67 x 2.83”) in black anodized
aluminum. Front and back with
shockproof ABS plastic and
transparent cover.
Environment
14 to 122°F (-10 to 50°C);
RH 95% non-condensing
Weight/Panel Cutout
2.2 lb. (1 Kg )/5.55 x 2.71”
(141 x 69 mm)
HI 8427
HI 931001
pH and ORP electrode simulator
pH and ORP electrode simulator
Water Analysis & Control Division
HI 8720/HI 943500
...easy to install ORP and conductivity controllers..
HI 8720
Panel Mounted ORP
Controller
•
•
•
•
•
•
Single set point version with selection of
reducing or oxidizing dosage.
Automatic diagnostic controls can be user
activated to check 0 mV and offset status.
The alarm band is user-selectable from 10 to
200 mV and will be activated when the mV
level deviates from the set point by more than
the selected alarm value.
When linked to the consent contacts of the
HI 8710 pH controller, PDCD* ensures that
ORP dosing will start only when the pH level
is corrected.
Two models are available, one with direct input
from an ORP electrode (“E” type) and another
for a 2-wire current loop of 4 to 20 mA from
an ORP transmitter (“T” type).
Isolated recorder output in either 0 to 20 mA
configuration or 4 to 20 mA.
*pH Dosing Consent Device
SPECIFICATIONS
Model
Range
Resolution
Accuracy (@20°C/68°F)
Typical EMC Deviation
Input
Calibration
Readout
Recorder Output
Setpoint Relay/
Alarm Relay
Power Supply
Enclosure
Environment
Weight/Panel Cutout
HI 8720E
-1000 to 1000 mV
1 mV
±5 mV
±6 mV
High Impedance 1012 ohm
Slope: 90 to 110% by
slope trimmer
4-digit LCD plus graphic symbols
0 to 20 mA (HI 8720E020) or
4 to 20 mA (HI 8720E420)
(isolated)
One, isolated, 2 A, Max. 240 V,
resistive load, 1,000,000
strokes
110/115V or 220/240V; 50/60 Hz
DIN 43 700 144 x 72 mm
(5.67 x 2.83”) in black
anodized aluminum. Front and
back with shockproof ABS
plastic and transparent cover.
14 to 122°F (-10 to 50°C);
RH 95% non-condensing
2.2 lb. (1 Kg )/5.55 x 2.71”
(141 x 69 mm)
Accessories for HI 8720E
HI 2002/5 ORP Pt electrode with 16.5’ (5 m) cable
HI 7020L
ORP testing sol. 200/275 mV (500 mL)
HI 7091L
Reducing solution (500 mL)
HI 7092L
Oxidizing solution (500 mL)
HI 8427
pH and ORP electrode simulator
HI 931001 pH and ORP electrode simulator
Hanna Instruments
HI 943500
Panel Mounted
Conductivity Controller
•
•
•
Direct connection of up to 67' (20 m) without
the need of intermediate amplifiers to the
HI 7638 conductivity probe.
An auto-diagnostic test of the offset and slope
determines the status of the instrument.
Available in four models with different ranges to
cover conductivity measurement from deionized water to brine.
•
•
•
Recorder output in 4 to 20 mA configuration.
LED indicators identify whether the controller is
in operational mode or selection mode.
The Hanna HI 7638 potentiometric conductivity
probe provides automatic temperature
compensated measurements.
SPECIFICATIONS
Model
HI 943500A
HI 943500B
HI 943500C
HI 943500D
Range
0.0 - 199.9 mS/cm
0.00 - 19.99 mS/cm
0 - 1999 µS/cm
0.0 - 199.9 µS/cm
Resolution
0.1 mS/cm
0.01 mS/cm
1 µS/cm
0.1 µS/cm
Accuracy (@20°C/68°F)
±2% F.S.
Typical EMC Deviation
±2.5% F.S.
Temp. Comp.
Automatic from 32 to 140°F (0 to 60°C) with 2% temperature coefficient
Readout
4-digit LCD plus graphic symbols
Recorder Output
4 to 20 mA (isolated)
Setpoint Relay
One, isolated, 2 A, Max. 240V, resistive load, 1,000,000 strokes
Alarm Relay
One, isolated, 2 A, Max. 240V, resistive load, 1,000,000 strokes
Power Supply
110/115V or 220/240V; 50/60 Hz
Enclosure
DIN 43 700 144 x 72 mm (5.67 x 2.83”) in black anodized aluminum. Front and back with
shockproof ABS plastic and transparent cover.
Environment
14 to 122°F (-10 to 50°C); RH 95% non-condensing
Weight/Panel Cutout
2.2 lb. (1 Kg )/5.55 x 2.71” (141 x 69 mm)
Accessories for HI 943500
HI 7638
Platinum conductivity probe
HI 7030L
12880 µS/cm calibration sol. (500 mL)
HI 7031L
1413 µS/cm calibration sol. (500 mL)
HI 7033L
HI 7034L
84 µS/cm calibration sol. (500 mL)
80000 µS/cm calibration sol. (500 mL)
Water Analysis & Control Division
Electrodes
HI 1002/5
Combination pH Electrode
HI 2002/5
Combination ORP Platinum Electrode
HI 7638
Submersion/in-line conductivity probe
...quality electrodes for high pressure
industrial applications.
SPECIFICATIONS
Model
Reference System
Junction
Type
Electrolyte
Temperature
Max. Pressure
Lead
Connector
Cable
HI 1002/5
Double
Teflon®
Polymer
23 to 176°F (-5 to 80°C)
6 bar (87 psi)
BNC
16.5’ (5 m)
SPECIFICATIONS
Model
Reference System
Junction
Type
Electrolyte
Temperature
Max. Pressure
Lead
Connector
Cable
HI 2002/5
Double
Teflon®
Polymer
23 to 176°F (-5 to 80°C)
6 bar (87 psi)
BNC
16.5’ (5 m)
SPECIFICATIONS
Model
Temp. Comp.
Body Material
Working Temperature
Max. Pressure (@25°C/77°F)
HI 7638
Automatic 32 to 122°F
(0 to 50°C)
Ultem®
32 to 248°F (0 to 120°C)
5 bar (72.5 psi)
HI 5001/5
Stainless steel Pt 100 probe
Authorized Distributor www.clarksonlab.com
For more information contact: Hanna Instruments, Inc.
43180 Business Park Drive, Suite 201, Temecula, CA 92590
Tel.: 888 426.6222 • Fax: 909 693.5213
email: westcoast@hannainst.com • www.hannainst.com