The N-TRON® 7018FX2-HV gigabit capable

The N-TRON® 7018FX2-HV gigabit capable
THE INDUSTRIAL NETWORK COMPANY
The N-TRON® 7018FX2-HV gigabit capable Industrial Ethernet
Switch offers outstanding performance and ease of use. It is a fully
managed switch, ideally suited for connecting Ethernet enabled
devices in railway, industrial and security applications.
PRODUCT FEATURES
• Fourteen 10/100BaseTX RJ-45 Ports
• Two 100BaseFX Ports, ST or SC Style
• Two Optional SFP (Mini-GBIC) Gigabit Transceivers
• 1000BaseSX/LX Fiber with LC style connectors or
• 1000BaseT Copper with RJ-45 connectors
• -40oC to 70oC Operating temperature
• ESD and Surge Protection Diodes on all Ports
• Auto Sensing 10/100BaseTX, Duplex, and MDIX
• Redundant Power Inputs (40-160VDC)
• Configurable Alarm Contact & Bi-Color Fault Status LED
Fully Managed Features
• SNMP v1, v2, v3 and Web Browser Management
• Detailed Ring Map and Fault Location Charting
• N-Ring™ Technology with ~30ms Healing
• N-View™ OPC Monitoring
• N-Link™ Redundant N-Ring Coupling
• Plug-and-play IGMP Support
• 802.1Q tag VLAN and Port VLAN
• 802.1p QoS and Port QoS
• EtherNet/IP™ CIP Messaging
• LLDP (Link Layer Discovery Protocol)
• Port Trunking
• Port Mirroring
• 802.1d, 802.1w, 802.1D RSTP
• DHCP Server, Option 82 relay, Option 61, IP Fallback
• Port Security—MAC Address Based
Management Features
The 7018FX2-HV offers several management functions that can be
easily configured using a web browser.
IGMP Snooping - Internet Group Management Protocol allows the
7018FX2-HV switch to forward and filter multicast traffic intelligently.
VLAN - Virtual Local Area Network allows you to segment the switch
in order to create two or more separate local area network domains.
QoS - Quality of Service provides prioritization of network traffic in
order to provide better network service. QoS improves the latency of
prioritized Ethernet packets required for ring management, real-time,
and other interactive applications.
Port Trunking - Trunking (link aggregation) enables multiple physical
ports to be linked together and function as one uplink to another
N-TRON trunking capable switch configured in the same manner,
thereby increasing the bandwidth between switches. This configuration
can provide increased bandwidth and redundancy to applications
requiring high levels of fault tolerant operation.
Port Mirroring - Allows the traffic on one port to be duplicated and
sent to a designated mirror port. Port mirroring is used to monitor
Ethernet traffic on the designated source port using the assigned
mirror port.
DHCP-DHCP Server/Client automates the assignment of IP addresses.
DHCP Option 82 assures that if a device on a specific port is replaced,
the replacement receives the same IP address as the original device.
Shown with Optional Gigabit
SFP Transceivers installed
Rapid Spanning Tree Protocol
RSTP allows the switch to be configured in a ring or mesh topology,
and provides support for redundant path communications with high
speed (rapid) healing.
Remote Monitoring Options
For ease of configuration and monitoring, the 7018FX2-HV offers
web browser management and N-View OLE for process control (OPC)
server software. The N-TRON N-View software can be combined with
popular HMI software packages to add network traffic monitoring,
trending, and alarming to any application using N-TRON switches. In
addition, SNMP is available for switch link and status monitoring. The
alarm contact and status LED can be configured to respond to power
failure on power input 1 or input 2, N-Ring broken, partial break high,
partial break low, or if multiple ring managers are detected.
N-Ring Technology
N-TRON's 7018FX2-HV ring manager using N-TRON's N-Ring
technology offers expanded ring size capacity, detailed fault
diagnostics, and a standard healing time of ~30ms. The 7018FX2-HV
ring manager periodically checks the health of the ring via packets. If
the ring manager stops receiving these health check packets, it converts
the ring to a linear topology within ~30ms. When all switches in the
ring are N-TRON fully managed switches, a detailed ring map and
fault location chart will also be provided on the ring manager’s web
browser and OPC server to identfy the health status of the ring.
N-Link™ allows the linking of two N-Rings. Up to 250 fully managed
N-TRON switches can participate in N-Ring topologies.
Industrial Packaging and Specifications
The 7018FX2-HV is designed to operate in industrial environments.
It is housed in a rugged steel DIN-Rail enclosure. It has extended
industrial specifications and features to meet or exceed the operating
parameters of connected equipment. These include extended
temperature ratings, extended shock and vibration specs, redundant
power inputs, and high MTBF (greater than 2M hours).
Ease of Use
The 10/100BaseTX ports are auto sensing and auto configuring.
Each copper port is automatically negotiated for maximum speed
and performance by default, but can also be hard coded through the
user interface. The two optional gigabit ports support full 2000 Mb/s
communications via 1000BaseSX/LX/T. For added flexibility, these
SFP (Mini-GBIC) gigabit transceivers are field upgradable or can be
factory installed at the time of purchase.
For Sales and Support, Contact Walker EMD • www.walkeremd.com • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800
THE INDUSTRIAL NETWORK COMPANY
7018FX2 Specifications
Switch Properties
Number of MAC Addresses:
Aging Time:
Latency Typical:
Switching Method
:
8000
Programmable
2.6 μs
Store-and-Forward
Fiber Transceiver Characteristics
Fiber Length
2km*
15km**
40km**
TX Power Min
-19dBm
-15dBm
-5dBm
80km**
-5dBm
RX Sensitivity Max
-31dBm
-31dBm
-34dBm
-34dBm
Wavelength
1310nm
1310nm
1310nm
1550nm
* Multimode Fiber Optic Cable
** Singlemode Fiber Optic Cable
Case Dimensions
Height:
Width:
Depth:
Weight (max):
DIN-Rail Mount:
2.3"
8.3"
4.8"
3.3 lbs
35mm
(5.8 cm)
(21.0 cm)
(12.1 cm)
(1.5 kg)
SFP Gigabit Fiber Transceiver Characteristics
Fiber Length
550m for 50/125μm
275m for 62.5/125μm*
10km**
40km**
80km**
-9.5dBm
-17dBm
-9.5dBm
-20dBm
-2dBm
-22dBm
0dBm
-24dBm
1310nm
1310nm
1550nm
TX Power Min
RX Sensitivity Max
850nm
Wavelength
Electrical
Redundant Input Voltage:
Input Current (max):
BTU/hr:
N-TRON Power Supply:
40-160 VDC (Regulated)
160mA max @124VDC
67.7@124VDC
NTPS-48-2 (2A @ 48VDC)
Environmental
Operating Temperature:
Storage Temperature:
Operating Humidity:
Operating Altitude:
-40oC to 70oC
-40oC to 85oC
5% to 95%
(Non Condensing)
0 to 10,000 ft.
Shock and Vibration (bulkhead mounted)
Assumed Fiber Loss
3.5 to 3.75 dB/km
Laser Type
VCSEL
0.45 dB/km 0.35 dB/km 0.25 dB/km
FP
DFB
Connectors
10/100BaseTX:
100BaseFX:
Optional SFP Ports:
1000BaseT:
1000BaseSX:
Fourteen (14) RJ-45 Copper Ports
Two (2) SC or ST Fiber Duplex Ports
Up to Two (2) RJ-45 Gigabit
Copper Ports (optional)
Up to Two (2) LC Duplex Gigabit
Fiber Ports (optional)
Shock:
200g @ 10ms
Vibration/Seismic:
50g, 5-200Hz, Triaxial
Recommended Wiring Clearance
>2 Million Hours
Regulatory Approvals
Reliability
MTBF:
Network Media
10BaseT:
>Cat3 Cable
100BaseTX:
>Cat5 Cable
1000BaseT:
>Cat5e Cable
100BaseFX, 1000BaseSX Multimode: 50-62.5/125μm
100BaseFXE, 1000BaseLXSinglemode: 7-10/125μm
DFB
* SX Fiber Optic Cable
** LX Fiber Optic Cable
Front:
Side:
4"
1"
(10.16 cm)
(2.54 cm)
TUV-GS Safety Declaration of Conformity (EN 60950-1)
FCC/CE CFR 47 Part 15, Subpart B, Class A
EN55022, ICES-003
EN 61000-4-3/4/5/6
EN50155 for Railway Applications
GS/CE: EN60950-1
Contact Information
N-TRON Corp.
820 S. University Blvd., Suite 4E
Mobile, AL 36609 USA
TEL: (251) 342-2164
FAX: (251) 342-6353
Website: www.N-TRON.com
Email: N-TRON_info@N-TRON.com
N-TRON Asia
Suite #: 2267, 22/F, One Lujiazui
68 Yin Cheng Road Center,
Pudong New Area
200120 Shanghai, P.R. China
Phone: +86 (0) 21 6194 6777
Fax: +86 (0) 21 6194 6699
N-TRON Europe GmbH
Alte Steinhauserstr 19
6330 Cham / Zg Switzerland
TEL: +41 41 7406636
FAX: +41 41 7406637
REV 100726
® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Product names mentioned herein are for identification purposes only and may be trademarks
and/or registered trademarks of their respective company. Specifications subject to change without notice. The responsibility for the use and application of N-TRON products rests
with the end user. N-TRON makes no warranties as to the fitness or suitability of any N-TRON product for any specific application. N-TRON Corporation shall not be liable for any
damage resulting from the installation, use, or misuse of this product. Printed in USA.
For Sales and Support, Contact Walker EMD • www.walkeremd.com • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800
THE INDUSTRIAL NETWORK COMPANY
7018FX2-HV Industrial Ethernet Switch Ordering Information
7018FX2-XX-HV
7018FXE2-XX-YY-HV
NTSFP-TX
NTSFP-SX
NTSFP-LX-ZZ
NTPS-48-2
700-PM
URMK
Where:
Fourteen 10/100BaseTX Ports, Two Multimode 100BaseFX Fiber Optic Ports, Two Optional Gigabit SFP Ports
Fourteen 10/100BaseTX Ports, Two Singlemode 100BaseFX Fiber Optic Ports, Two Optional Gigabit SFP Ports
Optional SFP (Mini-GBIC) Transceiver with One 1000BaseT GB Copper Port
Optional SFP (Mini-GBIC) Transceiver with One 1000BaseSX Multimode GB Fiber Optic Port
Optional SFP (Mini-GBIC) Transceiver with One 1000BaseLX Singlemode GB Fiber Optic Port
DIN-Rail Power Supply 48V@2 Amp
Panel Mount kit
Universal Rack Mount Kit
XX = ST or SC, YY = 15, 40, or 80 for Singlemode, Blank for Multimode
E = Singlemode, and Blank Otherwise
ZZ = 10, 40, or 80 for GB Singlemode
If SFP Transceiver is not specified at the time of purchase, slots will remain blank with covers
® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Specifications subject to change without notice. Printed in USA.
For Sales and Support, Contact Walker EMD • www.walkeremd.com • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising