PDA200E Styler - Commercial Audio Solutions

PDA200E Styler - Commercial Audio Solutions
PDA200E
WALL MOUNTING INDUCTION
LOOP AMPLIFIER
Ideal for meeting rooms, lecture theatres,
churches, schools, TV lounges, shops and
other small to medium sized applications
Provides max. square room coverage of
120m2 (11m x 11m) or max. rectangular
room coverage of 250m2 (10m x 25m)
Straightforward internal screw connectors
Wall mountable for permanent installation
– ideal for schools and colleges where
rooms are often left unsupervised
Internal tamper-resistant drive, level and
tone controls
One balanced/unbalanced microphone input
One balanced/unbalanced line level input
Alert tone switch input for doorbells, fire
alarms, security systems, etc
100V line input for PA system connection
Fully automatic compressor-limiter
Full 2Ω drive capability for increased
coverage at higher frequencies
Compatible with SigNET’s unique
‘outreach plate’ input extension system
Available in a variety of kit formats to
suit a host of typical loop installations
Fully compliant with EN60118-4
(formerly BS6083) and BS7594:1993
The PDA200E has revolutionised the induction loop marketplace by
bringing the ability to understand, install and appreciate the technology
involved to a whole new client base.
Straightforward internal screw connectors and preset controls mean no
specialist audio experience or audio connectors are required. By following
the simple set-up procedure, no further adjustments are necessary, allowing
a top quality assistive listening system for the hard of hearing to be set-up
in its entirety by new and experienced installers alike.
No less than four easy-to-access inputs are provided: Balanced/unbalanced mic (with phantom power for use with electret mics).
Balanced/unbalanced line (for the connection of TV and other audio feeds).
Alert tone switch (a tone generator for use with doorbells, fire alarms, etc).
100V line (for the connection of PA system audio feeds).
The amplifier’s state-of-the-art current drive audio processing circuitry
includes an automatic compressor/limiter which maintains the loop signal
within a small dynamic range to improve intelligibility. Manual
adjustments can also be made using the amplifier’s internal tamperresistant drive, level and tone controls, allowing the system to be tailored
to suit the exact requirements of any room.
For ease of specification and installation the PDA200E is
available on its own or in the following kits formats:AKM1 Meeting/seminar room kit
AKR1 Waiting room kit
AKT1 TV/Music lounge kit
AKW1 Place of worship kit 1
AKW2 Place of worship kit 2
AKH1 Heath and fitness club kit
AKL1 Lecture room kit
AKU1 Retail unit kit
(the exact contents of each kit are listed overleaf)
Optional 100V line input
from PA system
APM
Omni-directional
microphone
Belden twin
pair screened
audio cable
A typical PDA200E
meeting/seminar room
installation using items
supplied in our AKM1 kit
Loop Cable
(not supplied see tech specs
for recommended
type)
PDA200E
POWER REQUIREMENTS
INPUTS
Three 5mm screw connector inputs are available - mic., line & 100V. If more than one is used, the signals are mixed
MICROPHONE
Input impedance
600Ω balanced/unbalanced
Sensitivity
2-5mV (-46db to -50db)
Phantom
12V
LINE
Input impedance
>10kΩ balanced/unbalanced
Sensitivity
0dbv (300mV rms to 1.5V rms)
100V LINE
Input impedance
200kΩ
Sensitivity
+40dbv
ALERT
Closing a volt-free switch across this input generates a 2kHz tone through the loop.
Should additional inputs be required, the PDA200E is compatible with SigNET’s outreach plate input extension system.
This allows up to ten extra mic or line level inputs to be daisy-chained to the PDA200E. See our separate datasheet for details.
OUTPUT
PDA200E Technical Specification
Type
Loop connector
Cable
Loop coverage (square room)
Loop coverage (rectangular room)
Loop drive current
Loop impedance
Current mode
Screw connector
1.0-2.5mm2
120m2 max. (e.g. 11m x 11m)
Up to 250m2 when shortest side of loop is no greater than 10m (e.g. 10m x 25m)
4A peak; 1.8A average
0.2 to 2Ω @ 1kHz
PERFORMANCE
Bandwidth
40Hz to 8kHz
Input dynamic range
36dB
Distortion
<0.5% THD
The PDA200E includes an amplitude compression stage that limits overload and has a dynamically variable ratio from 1:1 to10:1
INDICATORS & CONTROLS
LED indicators
User controls
Input peak (limit); output drive (1,2,3 peak current); power on (power)
One level control, adjustable between -35dB to +0dB for both line and microphone
One output drive control, giving a loop current adjustable between 40mA & 2.1A
One mid-range cut & boost tone control (frequency = 1kHz; cut= -17dB: boost =+17dB)
DIMENSIONS & WEIGHT
Width x Height x Depth / Weight
273 mm x 200 mm x 77 mm / 2.9kg (unpacked)
PDA200E KIT VARIANTS
AKM1 Meeting/seminar room kit
AKR1 Waiting room kit
AKT1 TV/music lounge kit
AKL1 Lecture room kit
AKW1 Place of worship kit 1
AKW1 Place of worship kit 2
AKU1 Retail Unit kit
AKH1 Heath and fitness club kit
1x
1x
1x
1x
1x
1x
1x
1x
1x
2x
1x
1x
1x
PDA200E and 1x AMP Omni-directional plated microphone.
PDA200E and 1x APL outreach plate (for the connection of paging systems).
PDA200E, 1x AMH handheld microphone c/w APJ outreach connection plate and
APS scart to dble phono lead c/w APL outreach plate (for the connection of TVs, etc)
PDA200E, 1x AMT tie/desk microphone c/w APJ outreach connection plate and
AML lectern microphone c/w APJ outreach connection plate.
PDA200E, 1x AML lectern microphone c/w APJ outreach connection plate and
APL outreach plate (for the connection of audio inputs from CD, tape decks, etc.
PDA200E, 1x AMR radio microphone c/w APQ outreach connection plate and
APXM outreach plate (for the connection of existing microphones)
PDA200E and 1x AML lectern microphone c/w APJ outreach connection plate.
PDA200E, 1x AMR radio microphone c/w APQ outreach connection plate and
APL outreach plate (for the connection of CD/tape decks, etc)
Approved Doc. No. DCS0002136 Rev1. SigNET operates a policy of continuous improvement & reserves the right to alter product specifications at its discretion & without prior notice. E&OE.
Mains voltage
230V ac
Power consumption
<80VA
Fuses
Internal mains input fuse 1A 20 mm (HRC)
The PDA200E requires fixed mains wiring fed from a 3A fuse spur located no more than 3m from the amplifier.