office network solutions catalog

office network solutions catalog
OFFICE NETWORK SOLUTIONS CATALOG
Asia Pacific
SYSTEMS BY NAME:
1. MPO/MPOptimate System................................................. 1
2. MRJ21 System......................................................................25
3. Sigma-Link System............................................................35
4. Mixed Media Platform....................................................... 41
5. FiberGuide System........................................................... 49
6. Storage Area Management (SAM).............................. 91
7. Core VSM System.............................................................. 97
8. Managed Connectivity...................................................103
9. Optical LAN Solutions.................................................... 125
10. AMP CO System............................................................... 133
SYSTEMS BY TECHNOLOGY:
11. Fiber Optic Cabling.........................................................149
12. Modular Twisted Pair Cabling....................................203
13. Home Net-works Residential Cabling....................293
14. Commercial and Industrial Ethernet LAN.............299
15. Administration & Labeling..........................................307
16. Part Number Index........................................................... 311
318108AE 12/13 www.te.com/enterprise-asia
i
What's New?
INTRODUCING TE CONNECTIVITY'S FIRST OFFICE NETWORK SOLUTIONS
CATALOG WITH THE COMBINED AMP NETCONNECT AND KRONE
PORTFOLIOS FOR THE ASIA REGION
This edition of the Office Network Product Catalog is the first catalog for our Asia based
customers that features products from both the AMP NETCONNECT and KRONE portfolios.
This means that TE Connectivity can now offer you a choice from the best of both worlds
to address all of your cabling infrastructure needs, no matter if it's a Data Center, an Office
Complex or a Campus environment.
In addition to the existing products from these two world class brands, you'll find many
exciting, new products as featured on this double page.
The catalog is split into two main sections: the first (chapters 1-10) contains our products
organised by the name of the system, and the second (chapters 11-16) makes it easy to find
products by technology for example, Twisted Pair or Fiber Optic.
You'll also find useful cross-references in each section to make sure you don't miss the
product you are looking for that may be listed in a different section.
24-Fiber MPOptimate System
TE's 24 Fiber MPOptimate system delivers future proof, high density and
modular connectivity for 10, 40 and 100Gb/s data center applications.
The 24-fiber MPOptimate system allows data center managers to follow
a common sense methodology that offers:
• Simple and cost-effective migration path from 10 GbE to 40 and 100 GbE
• Consistent fiber infrastructure for the next three generations of
active equipment
• Improved insertion and return loss performance over standard
MPO solutions
• Uniformity of designs, installations, MACs and system management
• Reduced diameter cables for easier cable management and routing
Learn more about the MRJ21 XG System from page 11
MRJ21 XG System – A Pre-Connectorized Plug & Play 10 GbE
Copper System
The MRJ21 XG System supports 10 Gigabit Ethernet throughput in all
architectures where copper cabling is required. This pre-terminated Plug
& Play system enables the data center manager to quickly add additional
capacity or services whilst guaranteeing data throughput performance 100%
of the time. Also, the lower cable volume deployed in the data center can
reduce containment costs, and present less of an obstruction to the airflow
entering and exiting the servers and switches.
Learn more about the MRJ21 XG System from page 26
Sigma-Link Quick-Fit System - A pre-terminated
bundled Copper Cabling Solution
The Sigma-Link Quick-Fit System can be deployed in any application that
requires copper twisted pair cabling as the medium of transport. It can be
used to connect Users to Switches, Switches to other Switches, or Switches to
Servers. Ranging from Category 6 to Category 7A, Sigma-Link supports up to
10 Gigabit Ethernet transmission, and beyond, allowing very high bandwidth
applications and protocols to be supported in the future. As a Housing-toHousing solution it can be quickly located into our UCP panels, taking minimal
time to deploy and configure a new channel in the network.
Learn more about the Sigma-Link Quick-Fit System from page 36
ii
www.te.com/enterprise-asia 12/13 318108AE
What's New?
Storage Area Management – Simplify your
Optical Cable Management
TE’s Storage Area Management (SAM) Solution for SAN infrastructures is
designed to reduce the bulkiness of cabling and connectors in the data center
by up to 80% and enable high-density deployment with fewer costly cabinet or
infrastructure upgrades. SAM can help you save time, reduce costs, maximize
efficiency, and free up much needed space in your data center. It takes the
complexity out of cable management, and optimizes the performance of your
data center floor space, racks and electronics.
De-clutter your racks for a highly organized, eco-friendly network infrastructure
and deliver operational efficiency to your SAN cabling.
Learn more about the SAM Solution from page 92
Core Vertical Switch Management – Deliver Efficiency
to the Core of Your DC
The Core Vertical Switch Management platform (Core VSM) is an innovative
solution to the challenges posed in the data center by high-density core
switches with a vertical blade configuration.
The platform consists of a cable management guide that fits above the switch
and copper or fiber modules that provide connections for blades of either
media. The complete Core VSM platform can be installed within an 800 mm
wide cabinet, saving valuable white space in the data center.
Within the Core VSM platform, all patch cables, whether fiber or copper, are
managed vertically with only one length of patch cord being required to patch
within a frame which simplifies the build process and ongoing logistics.
Learn more about the Core VSM Solution from page 98
Infrastructure Configuration Manager - Know Your Network!
The Infrastructure Configuration Manager (ICM) is software specifically
designed to operate as part of TE's Managed Connectivity solution. ICM can be
used by a full range of companies – small, medium and enterprise customers
can utilize the software to accurately document the physical infrastructure
that their business relies on. This software engine enables the automated,
accurate, real-time physical layer management of TE's two hardware platforms:
AMPTRAC 9th wire system and QUAREO connection point identification
technology, providing customers with a single software for both solutions. ICM
provides a live graphical view of the physical layer topology, including Layer
2 and Layer 3 devices. The latest addition to this software solution is a mobile
app for smartphones (ICM Mobile) which allows a technician to access the ICM
desktop functionalities like Work Orders, Events and several settings from a
mobile device.
Learn more about ICM from page 104
Optical LAN Solutions – New Ways of Delivering
High-Bandwidth to Each Desktop
TE Connectivity offers a complete, end-to-end PON infrastructure solution
called Optical LAN Solution (OLS). From the data center to the desktop, our
customers have tapped the experience and innovation of TE to build their
PON networks. TE’s suite of end-to-end connectivity is truly comprehensive
and takes a single strand of singlemode fiber from the Data Center all the
way to the individual desk or end device location.
Router
OLT
Fiber Panel
FDH - Fiber Distribution Hub
Fiber Wall Plate
ONT
FDT
Fiber Distribution Terminal
Learn more about OLS from page 126
318108AE 12/13 www.te.com/enterprise-asia
iii
TE Enterprise Networks 25 Year Warranty
WARRANTY SUPPORT FOR THE NEXT 25 YEARS
There are many structured cabling warranties available on the market today but
only the TE25 Warranty provides all of this in one package, backed by a multibillion dollar company with connector technology at the heart of its strategy.
TE Connectivity is committed to being the world’s leading provider of
enterprise networks infrastructure solutions. With connector technology as
the prime focus of our business and a track record in the structured cabling
industry through our AMP NETCONNECT and KRONE brands, a TE25 warranty
provides the added assurance of a warranty backed by a company with longterm industry stability.
THE TE 25 YEAR SYSTEM WARRANTY PROVIDES
COVER ON THE COMPLETE CABLING SYSTEM
• Comprises cable, connectors, connecting hardware and patch cords
• Covers defects in either materials or workmanship for the full 25 years
• Ensures that all signal carrying components meet the prescribed
mechanical and transmission specifications for these products
• Includes repair or replacement of defective products— at our cost
• Includes the labor cost
DIRECT TO END USER
TE CONNECTIVITY
The TE25 Warranty is a contract made directly between
TE Connectivity and the customer.
How It Works:
1. End user selects TE Connectivity Cabling system
2.End user selects ND&I program installer
TRAINING
ENTERPRISE
NETWORKS
ND&I PROGRAM
3.ND&I installs, tests and documents the cabling system
INSTALLING
&
TESTING
4.ND&I provides defined project documentation
and test results to TE Connectivity
5.TE grants warranty to end user
THE TE25 COMPONENT WARRANTY
For those occasions when a full system warranty is not appropriate, for
example where confidentiality or security issues prevent full details of the
system being shared with TE, a component warranty is available.
Less stringent in terms of the registration requirements and not as
comprehensive as the system warranty, it still provides 25 year cover
for all TE components to the latest international standards.
iv
www.te.com/enterprise-asia 12/13 318108AE
END USER
1. MPO/MPOptimate System
MPO/MPOptimate Installation and Polarity.......................................... 02
12 Fiber MPOptimate System...................................................................... 03
12 Fiber MPO System....................................................................................... 08
24 Fiber MPOptimate System........................................................................11
MPO/MPOptimate Panels & Accessories..................................................17
Q3000 Series MPO Fiber Panels.................................................................21
MPO/MPOptimate Cleaning Tools..............................................................23
318108AE 12/13 www.te.com/enterprise-asia
01
MPO/MPOptimate System
MPO/MPOptimate Installation and Polarity
MPO/MPOptimate installation and polarity
1. MPO/MPOptimate System
In each fiber optic system, the link from source (Tx) to receiver (Rx)
needs to be flipped once.
In a complete MPO/MPOptimate link this flipping is provided
by one flipped cassette, while all other components in this link
shall be installed as straight version.
MPOptimate ready for 10, 40 and 100 Gb/s
The MPOptimate system is designed to support 10G Ethernet and
4/8/16G Fiber Channel applications through the complete
structure of a Data Center, as specified in ISO/IEC 24764, EN
50173-5 and TIA/EIA 942. The MPOptimate system is designed
to have 6 cassettes per link for 10 Gb/s with a full 300 meter
support on OM3 fibers and 550 meter on OM4 fibers.
It offers one passive channel from the end equipment to
the core switch without the need of repeating signals for
amplifying reasons. When using the MPOptimate cabling
system, the owner can replace aggregation switches by a
patch cord without changing the passive infrastructure.
ENI
MD
ZD
LDP
EO
EQP
Distributor
in accordance
with ISO/IEC 11801
Network access
cabling subsystem
Main distribution
cabling subsystem
Zone distribution
cabling subsystem
Equipment
cabling
Generic cabling system
The system offers already today a fully 40 and 100 Gb/s
capability and seamless migration.
Length tables for MPO/MPOptimate trunks and fan-out assemblies
LENGTH TABLE A:
Y- -X
Length
Y- -X Length
Y- -X
Length
Y- -X
Length
Y- -X
Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
0- -2
2m
1- -3
13 m
2- -4
24 m
3- -5
35 m
4- -6
46 m
5- -7
57 m
6- -8
68 m
7- -9
79 m
9- -0
90 m
0- -3
3m
1- -4
14 m
2- -5
25 m
3- -6
36 m
4- -7
47 m
5- -8
58 m
6- -9
69 m
8- -0
80 m
9- -1
91 m
0- -4
4m
1- -5
15 m
2- -6
26 m
3- -7
37 m
4- -8
48 m
5- -9
59 m
7- -0
70 m
8- -1
81 m
9- -2
92 m
0 -5
5m
1- -6
16 m
2- -7
27 m
3- -8
38 m
4- -9
49 m
6- -0
60 m
7- -1
71 m
8- 2
82 m
9- -3
93 m
0- -6
6m
1- -7
17 m
2- -8
28 m
3- -9
39 m
5- -0
50 m
6- -1
61 m
7- -2
72 m
8- -3
83 m
9- -4
94 m
0- -7
7m
1- -8
18 m
2- -9
29 m
4- -0
40 m
5- -1
51 m
6- -2
62 m
7- -3
73 m
8- -4
84 m
9- -5
95 m
0- -8
8m
1- -9
19 m
3- -0
30 m
4- -1
41 m
5- -2
52 m
6- -3
63 m
7- -4
74 m
8- -5
85 m
9- -6
96 m
0- -9
9m
2- -0
20 m
3- -1
31 m
4- -2
42 m
5- -3
53 m
6- -4
64 m
7- -5
75 m
8- -6
86 m
9- -7
97 m
1- -0
10 m
2- -1
21 m
3- -2
32 m
4- -3
43 m
5- -4
54 m
6- -5
65 m
7- -6
76 m
8- -7
87 m
9- -8
98 m
1- -1
11 m
2- -2
22 m
3- -3
33 m
4- -4
44 m
5- -5
55 m
6- -6
66 m
7- -7
77 m
8- -8
88 m
9- -9
99 m
1- -2
12 m
2- -3
23 m
3- -4
34 m
4- -5
45 m
5- -6
56 m
6- -7
67 m
7- -8
78 m
8- -9
89 m
LENGTH TABLE B:
Y- -X
Length
Y- -X Length
Y- -X
Length
Y- -X
Length
Y- -X
Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
9- -9
100 m
1- -1
111 m
2- -2
122 m
3- -3
133 m
4- -4
148 m
5- -5
170 m
6- -6
192 m
7- -7
270 m
8- -8
460 m
0- -1
101 m
1- -2
112 m
2- -3
123 m
3- -4
134 m
4- -5
150 m
5- -6
172 m
6- -7
194 m
7- -8
280 m
8- -9
480 m
0- -2
102 m
1- -3
113 m
2- -4
124 m
3- -5
135 m
4- -6
152 m
5- -7
174 m
6- -8
196 m
7- -9
290 m
9- -0
500 m
0- -3
103 m
1- -4
114 m
2- -5
125 m
3- -6
136 m
4- -7
154 m
5- -8
176 m
6- -9
198 m
8- -0
300 m
0- -4
104 m
1- -5
115 m
2- -6
126 m
3- -7
137 m
4- -8
156 m
5- -9
178 m
7- -0
200 m
8- -1
320 m
0- -5
105 m
1- -6
116 m
2- -7
127 m
3- -8
138 m
4- -9
158 m
6- -0
180 m
7- -1
210 m
8- -2
340 m
0- -6
106 m
1- -7
117 m
2- -8
128 m
3- -9
139 m
5- -0
160 m
6- -1
182 m
7- -2
220 m
8- -3
360 m
0- -7
107 m
1- -8
118 m
2- -9
129 m
4- -0
140 m
5- -1
162 m
6- -2
184 m
7- -3
230 m
8- -4
380 m
0- -8
108 m
1- -9
119 m
3- -0
130 m
4- -1
142 m
5- -2
164 m
6- -3
186 m
7- -4
240 m
8- -5
400 m
0- -9
109 m
2- -0
120 m
3- -1
131 m
4- -2
144 m
5- -3
166 m
6- -4
188 m
7- -5
250 m
8- -6
420 m
1- -0
110 m
2- -1
121 m
3- -2
132 m
4- -3
146 m
5- -4
168 m
6- -5
190 m
7- -6
260 m
8- -7
440 m
02
www.te.com/enterprise-asia 12/13 318108AE
MPO/MPOptimate System
12 Fiber MPOptimate System
MPOptimate pre-terminated trunks
1. MPO/MPOptimate System
FEATURES
• Cable terminated with low loss 12 fiber MPOptimate connectors
• Terminated with female MPO connectors (male versions on request)
• OM3 or OM4 cable performance, LSZH construction
• Connector performance: Attenuation ≤ 0.35 dB (max); RL ≥ 28 dB (min)
• The trunks are equipped with midi fan-out and
round cable MPO tails protected with transparent protection sleeve
• Factory pre-terminated assemblies
• All products with protocol, for constant and reliable quality
• Available in 12, 24 and 48 fiber
• Packaging: ≤50 m in box, >50 m on reel
• Re-usable pulling socks can be ordered separately.
12 - 24 fiber trunks Part Number 2055567-1
48 fiber trunks Part Number 2055567-2
ORDERING INFORMATION
Description
Part Number
2-99 m – table A
Part Number
100-500 m – table B
12 fiber; OM4 XGA 10 Gb/s; Straight; A wiring
Y-2055576-X
Y-2055577-X
24 fiber; OM4 XGA 10 Gb/s; Straight; A wiring
Y-2055578-X
Y-2055579-X
48 fiber; OM4 XGA 10 Gb/s; Straight; A wiring
Y-2160075-X
Y-2160076-X
12 fiber; OM3 XG 10 Gb/s; Straight; A wiring
Y-2055611-X
Y-2055612-X
24 fiber; OM3 XG 10 Gb/s; Straight; A wiring
Y-2055715-X
Y-2055716-X
48 fiber; OM3 XG 10 Gb/s; Straight; A wiring
Y-2160073-X
Y-2160074-X
For available lengths: see page 02
318108AE 12/13 www.te.com/enterprise-asia
03
MPO/MPOptimate System
12 Fiber MPOptimate System
MPOptimate to LC Quick-Fit cassettes
1. MPO/MPOptimate System
FEATURES
• Pre-terminated low loss cassettes
• Front: 6 x optimized LC Duplex or 6 x optimized LC Quad
• Back: 1 or 2 low loss MPOptimate connector(s)
• Available in straight or flipped pair version
• Optical cassette performance in OM4:
Attenuation ≤ 0.35 dB/cassette (max)
RL ≥ 27 dB (min)
• All products with protocol, for constant and reliable quality
• Fits in TE CONNECTIVITY Quick-Fit patch panels
with maximum density of 4 cassettes per 1U
• Port number labeling and additional label strip included
ORDERING INFORMATION
Description
Pairs straight
Part Number
Pairs flipped
Part Number
1 x MPOptimate to 6 x LC Duplex (12 fiber); OM3/OM4 XGA 10 Gb/s
1671226-5
1-1671226-5
2 x MPOptimate to 6 x LC Quad (24 fiber); OM3/OM4 XGA 10 Gb/s
1671227-5
1-1671227-5
Pairs straight
Part Number
Pairs flipped
Part Number
1671228-3
1-1671228-3
MPOptimate to SC Quick-Fit cassettes
FEATURES
• Pre-terminated low loss cassettes
• Front: 6 x optimized SC Duplex
• Back: 1 x low loss MPOptimate connector
• Available in straight or flipped pair version
• Optical cassette performance in OM3:
Attenuation ≤ 0.35 dB (max)
RL ≥ 27 dB (min)
• All products with protocol, for constant and reliable quality
• Fits in TE CONNECTIVITY Quick-Fit patch panels
with maximum density of 4 cassettes per 1U
• Port number labeling and additional label strip included
ORDERING INFORMATION
Description
1 x MPOptimate to 6 x SC Duplex; (12 fiber): OM3 XG 10 Gb/s
04
www.te.com/enterprise-asia 12/13 318108AE
MPO/MPOptimate System
12 Fiber MPOptimate System
MPOptimate patch cords
1. MPO/MPOptimate System
FEATURES
• Low loss MPOptimate 12 fiber MPO round cable patch cord
• Terminated with male and/or female MPOptimate connectors
• Cable performance: OM4; OM3 XG 10 Gb/s; LSZH construction
• Connector performance: Attenuation ≤ 0.35 dB (max.); RL ≥ 28 dB (min)
• All products with protocol, for constant and reliable quality
• Available in female/female and male/female version
in straight “A” wiring and total flipped “B” wiring
Color: aqua
LENGTH TABLE:
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
9- -0
0,5
9- -5
5,5
1- -1
11
2- -1
21
3- -1
31
4- -1
41
5- -1
51
6- -1
61
7- -1
71
0- -1
1,0
0- -6
6,0
1- -2
12
2- -2
22
3- -2
32
4- -2
42
5- -2
52
6- -2
62
7- -2
72
9- -1
1,5
9- -6
6,5
1- -3
13
2- -3
23
3- -3
33
4- -3
43
5- -3
53
6- -3
63
7- -3
73
0- -2
2,0
0- -7
7,0
1- -4
14
2- -4
24
3- -4
34
4- -4
44
5- -4
54
6- -4
64
7- -4
74
9- -2
2,5
9- -7
7,5
1- -5
15
2- -5
25
3- -5
35
4- -5
45
5- -5
55
6- -5
65
7- -5
75
0- -3
3,0
0- -8
8,0
1- -6
16
2- -6
26
3- -6
36
4- -6
46
5- -6
56
6- -6
66
7- -6
76
9- -3
3,5
9- -8
8,5
1- -7
17
2- -7
27
3- -7
37
4- -7
47
5- -7
57
6- -7
67
7- -7
77
0- -4
4,0
0- -9
9,0
1- -8
18
2- -8
28
3- -8
38
4- -8
48
5- -8
58
6- -8
68
7- -8
78
9- -4
4,5
9- -9
9,5
1- -9
19
2- -9
29
3- -9
39
4- -9
49
5- -9
59
6- -9
69
7- -9
79
0- -5
5,0
1- -0
10
2- -0
20
3- -0
30
4- -0
40
5- -0
50
6- -0
60
7- -0
70
8- -0
80
ORDERING INFORMATION
Description
Pairs straight
Part Number
Pairs total flipped
Part Number
MPOptimate female – MPOptimate female patch cord; OM3 XG 10 Gb/s
Y-2160135-X
Y-2160193-X
MPOptimate female – MPOptimate female patch cord; OM4 XGA 10 Gb/s
Y-2160136-X
Y-2160194-X
MPOptimate female – MPOptimate male patch cord; OM3 XG 10 Gb/s
Y-2160139-X
Y-2160197-X
MPOptimate female – MPOptimate male patch cord; OM4 XGA 10 Gb/s
Y-2160140-X
Y-2160198-X
318108AE 12/13 www.te.com/enterprise-asia
05
MPO/MPOptimate System
12 Fiber MPOptimate System
MPOptimate Fan-Out cable assemblies
1. MPO/MPOptimate System
FEATURES
• Low loss transition from MPO to LC or SC tails 2 mm
• Terminated with female or male MPOptimate connectors
• Cable performance: OM4 or OM3 XG 10 Gb/s; LSZH construction
• Optical performance:
MPO connector: Attenuation ≤ 0.35 dB (max.); RL ≥ 28 dB (min)
LC/SC connector: Attenuation≤ 0.15 dB (max); RL ≥ 35 dB (min)
• All products with protocol, for constant and reliable quality
• Tail lengths: 4 x 40 cm, 4 x 50 cm, 4 x 60 cm.
• The trunks are equipped with midi fan-out and round cable MPO tails
• All tails are protected with transparent protection sleeve
• Packaging: ≤50 m in box, >50 m on reel
• Re-usable pulling socks can be ordered separately. Part Number 2055567-1
ORDERING INFORMATION
Description
Part Number
2-99 m – table A
Part Number
100-500 m – table B
1 x MPOptimate female to 12 x LC Simplex; OM4 XGA 10 Gb/s
Y-2055580-X
Y-2055581-X
1 x MPOptimate female to 12 x SC Simplex; OM4 XGA 10 Gb/s
Y-2160114-X
Y-2160115-X
1 x MPOptimate female to 12 x LC Simplex; OM3 XG 10 Gb/s
Y-2055623-X
Y-2055624-X
1 x MPOptimate female to 12 x SC Simplex; OM3 XG 10 Gb/s
Y-2160112-X
Y-2160113-X
1 x MPOptimate male to 12 x LC Simplex; OM4 XGA 10 Gb/s
Y-2160146-X
Y-2160147-X
1 x MPOptimate male to 12 x SC Simplex; OM4 XGA 10 Gb/s
Y-2160126-X
Y-2160127-X
1 x MPOptimate male to 12 x LC Simplex; OM3 XG 10 Gb/s
Y-2055600-X
Y-2055704-X
For available lengths: see page 02
MPOptimate System LC and SC patch cords
FEATURES
• Patch cords with optimized LC and SC connectors
• Cable performance: OM4 or OM3 XG 10 Gb/s; LSZH construction
• Optical performance:
– LC connector: Attenuation≤ 0.15 dB (max); RL ≥ 35 dB(min)
– SC connector: Attenuation≤ 0.15 dB (max); RL ≥ 35 dB(min)
• All products with protocol, for constant and reliable quality
ORDERING INFORMATION
Y- -X
Length
0- -1
1m
0- -3
3m
0- -5
5m
1- -0
10 m
Description
Part Number
Patch cord LC Duplex – LC Duplex; OM3 XG 10 Gb/s
Y-1920743-X
Patch cord SC Duplex – SC Duplex; OM3 XG 10 Gb/s
Y-2055108-X
Patch cord LC Duplex – SC Duplex; OM3 XG 10 Gb/s
Y-2055109-X
Patch cord LC Duplex – LC Duplex; OM4 XGA 10 Gb/s
Y-2160046-X
Patch cord SC Duplex – SC Duplex; OM4 XGA 10 Gb/s
Y-2160047-X
Patch cord LC Duplex – SC Duplex; OM4 XGA 10 Gb/s
Y-2160048-X
06
www.te.com/enterprise-asia 12/13 318108AE
MPO/MPOptimate System
12 Fiber MPO System
Pre-terminated MPO trunk cable, 12/24/48 fiber
1. MPO/MPOptimate System
FEATURES
• Factory pre-terminated assemblies
• Cables terminated with high density MPO connectors
• All products with protocol, for constant and reliable quality
• In OS2 design with LSZH sheath
• Available in lengths from 2 up to 500 m
• The trunks are equipped with midi fan-out and round cable MPO tails
protected with transparent protection sleeve available in 12, 24 and 48 fiber
(other fiber counts on request)
• Packaging: ≤50 m in box, >50 m on reel
• Re-usable pulling socks can be ordered separately.
12 and 24 fibre trunks Part number 2055567-1
48 fibre trunks Part number 2055567-2
ORDERING INFORMATION
Description
Part Number
2-99 m – table A
Part Number
100-500 m – table B
12 Fiber; SM; Straight “A” wiring
Y-2055711-X
Y-2055712-X
24 Fiber; SM; Straight “A” wiring
Y-2055713-X
Y-2055714-X
48 Fiber; SM; Straight “A”wiring
Y-2160077-X
Y-2160078-X
For available lengths: see page 02
318108AE 12/13 www.te.com/enterprise-asia
07
MPO/MPOptimate System
12 Fiber MPO System
MPO to LC Quick-Fit cassettes
1. MPO/MPOptimate System
FEATURES
• Simple and flexible premises fiber cabling
• Pre-terminated cassettes with either 1 or 2 MPO trunk
connections
(1 x 12 or 2 x 12 fibers) at rear
• 6 x LC Duplex (12 fibers) or 6 x LC Quad
(24 fibers) connection in the front
• All products with protocol, for constant and reliable quality
• Easy installation, moves, adds and changes
• Fits in all TE CONNECTIVITY Patch Panels for Quick-Fit Modules
• Panels accept up to 4 cassettes achieving up to 96 fiber
connections on 1U
ORDERING INFORMATION
Description
Pairs straight
Part Number
Pairs flipped
Part Number
1 x MPO to 6 x LC Duplex; SM
1671205-4
1-1671205-4
1 x MPO to 6 x LC APC Duplex; SM
1671205-6
1-1671205-6
2 x MPO to 6 x LC Quad; SM
1671206-4
1-1671206-4
2 x MPO to 6 x LC APC Quad; SM
1671206-6
1-1671206-6
Pairs straight
Part Number
Pairs flipped
Part Number
1 x MPO to 6 x SC Duplex; SM
1671207-4
1-1671207-4
1 x MPO to 6 x SC APC Duplex; SM
1671207-6
1-1671207-6
MPO to SC Quick-Fit cassettes
FEATURES
• Simple and flexible premises fiber cabling
• Pre-terminated cassettes with 1 MPO trunk connection
(1 x 12 fibers) at rear
• 6 x SC Duplex (12 fibers) connections in the front
• All products with protocol, for constant and reliable quality
• Easy installation, moves, adds and changes
• Fits in all TE CONNECTIVITY Patch Panels for Quick-Fit Modules
• Panels accept up to 4 cassettes on 1U
ORDERING INFORMATION
Description
08
www.te.com/enterprise-asia 12/13 318108AE
MPO/MPOptimate System
12 Fiber MPO System
MPO patch cords
1. MPO/MPOptimate System
FEATURES
• MPO patch cord
• Cable performance: OS2; LSZH 3.2mm round cable construction
• All products with protocol, for constant and reliable quality
• Available in female/female and male/female version in
straight “A” wiring and total flipped wiring ”B” wiring
LENGTH TABLE:
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
9- -0
0,5
9- -5
5,5
1- -1
11
2- -1
21
3- -1
31
4- -1
41
5- -1
51
6- -1
61
7- -1
71
0- -1
1,0
0- -6
6,0
1- -2
12
2- -2
22
3- -2
32
4- -2
42
5- -2
52
6- -2
62
7- -2
72
9- -1
1,5
9- -6
6,5
1- -3
13
2- -3
23
3- -3
33
4- -3
43
5- -3
53
6- -3
63
7- -3
73
0- -2
2,0
0- -7
7,0
1- -4
14
2- -4
24
3- -4
34
4- -4
44
5- -4
54
6- -4
64
7- -4
74
9- -2
2,5
9- -7
7,5
1- -5
15
2- -5
25
3- -5
35
4- -5
45
5- -5
55
6- -5
65
7- -5
75
0- -3
3,0
0- -8
8,0
1- -6
16
2- -6
26
3- -6
36
4- -6
46
5- -6
56
6- -6
66
7- -6
76
9- -3
3,5
9- -8
8,5
1- -7
17
2- -7
27
3- -7
37
4- -7
47
5- -7
57
6- -7
67
7- -7
77
0- -4
4,0
0- -9
9,0
1- -8
18
2- -8
28
3- -8
38
4- -8
48
5- -8
58
6- -8
68
7- -8
78
9- -4
4,5
9- -9
9,5
1- -9
19
2- -9
29
3- -9
39
4- -9
49
5- -9
59
6- -9
69
7- -9
79
0- -5
5,0
1- -0
10
2- -0
20
3- -0
30
4- -0
40
5- -0
50
6- -0
60
7- -0
70
8- -0
80
ORDERING INFORMATION
Description
Pairs straight
Part Number
Pairs total flipped
Part Number
MPO female – MPO female Patch Cord; SM
Y-2160137-X
Y-2160195-X
MPO male – MPO female Patch Cord; SM
Y-2160141-X
Y-2160199-X
318108AE 12/13 www.te.com/enterprise-asia
09
MPO/MPOptimate System
12 Fiber MPO System
MPO Fan-Out cable assemblies
1. MPO/MPOptimate System
FEATURES
• MPO round cable to LC or SC 12 x 2 mm tails
• Terminated with female or male MPO connectors
• Cable performance: OS2 in LSZH construction
• All products with protocol, for constant and reliable quality
• Tail lengths: 4 x 40cm, 4 x 50cm, 4 x 60cm
(other tail lenghts available on request)
• The trunks are equipped with midi fan-out and round cable MPO tails
• All tails are protected with transparent protection sleeve
• Packaging: ≤50 m in box, >50 m on reel
• Re-usable pulling socks can be ordered separately. Part Number 2055567-1
ORDERING INFORMATION
Description
Part Number
2-99 m – table A
Part Number
100-500 m – table B
1 x MPO female to 12 x LC Simplex; SM
Y-2160108-X
Y-2160109-X
1 x MPO female to 12 x SC Simplex; SM
Y-2160116-X
Y-2160117-X
1 x MPO male to 12 x LC Simplex; SM
Y-2160122-X
Y-2160123-X
1 x MPO male to 12 x SC Simplex; SM
Y-2160128-X
Y-2160129-X
For available lengths: see page 02
10
www.te.com/enterprise-asia 12/13 318108AE
MPO/MPOptimate System
24 Fiber MPOptimate System
24 Fiber MPOptimate System
1. MPO/MPOptimate System
Demand for bandwidth and storage is expanding at a
breathtaking rate within the data center, which means
that the environment is rapidly evolving, making
the impact on data center design and management
profound.
Networks will need to be ready to migrate from 10 to
40 to 100 GbE speeds dynamically, whilst data center
managers and designers need to be able to manage this
migration to maximize efficiency and responsiveness
while minimizing cost.
Preparing for this trend demands a simple yet robust
migration pathway.
As part of TE Connectivity’s data center solution, the
24 Fiber MPOptimate system enables such a plan,
supporting the migration of increasing data speeds
required to support the next generation of servers,
storage and switching platforms.
SYSTEM FEATURES:
• Low-loss 24 fiber MPOptimate modules
• Fast interfacing, “trouble free” of gender and polarity issues
• Low loss 24 fiber MPOptimate trunks
• Supporting 10/40/100GbE throughput
• A single trunking format that can be replicated and upgraded simply and flexibly
• Pre-engineered paths and polarity
• 24 Fiber trunk systems offer higher fiber utilization versus 12 fiber trunk systems
• Fewer trunks: less containment space needed leading to lower initial build costs.
• Fewer connections: faster time to turn up circuits
• Fewer components
• Standardized practices for design, installation, documentation and troubleshooting polarity
• Each product is individually tested to ensure that it’s performance meets or exceeds
the required standard. The test results are supplied with each product.
318108AE 12/13 www.te.com/enterprise-asia
11
MPO/MPOptimate System
24 Fiber MPOptimate System
MPOptimate 24f pre-terminated trunks
1. MPO/MPOptimate System
FEATURES
• Loose tube cable construction, ideal for
routing through cable tray or raceway
• Cable terminated with low loss 24
fiber MPOptimate connectors
• Terminated with female MPO
connectors (male versions on request)
• OM3, OM4 cable performance, LSZH construction
• Connector performance for OM3/OM4:
Attenuation ≤ 0.25 dB (max.);
RL ≥ 28 dB (min)
• The trunks are equipped with midi fan-out and 3.8mm round cable MPO tails (80cm)
• All tails are protected with transparent protection sleeve
• Factory pre-terminated assemblies
• All products with protocol, for constant and reliable quality
• Packaging: ≤50 m in box, >50 m on reel
• Re-usable pulling socks can be ordered separately. Part Number 2055567-1
Color: aqua
ORDERING INFORMATION
Part Number
2-99 m – table A
Part Number
100-500 m – table B
24 fiber; OM3; Straight A wiring;
Y-2160663-X
Y-2160664-X
24 fiber; OM4; Straight A wiring;
Y-2160608-X
Y-2160609-X
Description
For available lengths: see 02
12
www.te.com/enterprise-asia 12/13 318108AE
MPO/MPOptimate System
24 Fiber MPOptimate System
10Gb/s Cassettes – 1x24 fiber MPO to
6 LC Quad connectors
1. MPO/MPOptimate System
FEATURES
• Pre-terminated low loss cassettes
• Front: 6 x optimized LC Quad
• Back: 1 x 24 fiber low loss MPOptimate connector
• Optical cassette performance for OM3/OM4:
Attenuation≤ 0.35 dB(max.) RL ≥ 27 dB(min)
• All products with protocol, for constant and reliable quality
• Port number labelling and additional label strip included
ORDERING INFORMATION
Part Number
straight
Part Number
flipped
1x24 fiber MPO to 6x LC Quad OM4
2160266-5
1-2160266-5
1x24 fiber MPO to 6x LC Quad OM3
2160266-3
1-2160266-3
Description
40GbE (4 x 10GbE) Cassette –
1x24 fiber MPO to 6 LC Quad connectors
FEATURES:
• Quick-Fit design, fits in all UCP products
• OM4 bend insensitive fiber
• For channel with 40G MPO cassettes connected to
40G (4x10G) transceiver
• Cassette attenuation: typical 0.25dB/max. 0.35dB
• Cassette Return Loss: 27dB min
ORDERING INFORMATION
Description
Wire map
1x24 fiber MPO to 6x LC Quad
Special 40/10G
Part Number
2160640-5
40Gb/s Cassette – 1x24 fiber MPO
to 3x12 (8) fiber MPO connectors
FEATURES:
• Quick-Fit design, fits in all UCP products
• OM4 bend insensitive fiber
• Cassette attenuation: typical 0.36dB/max. 0.5dB
• Cassette Return Loss: 27dB min
ORDERING INFORMATION
Description
Wire map
Part Number
1x24 fiber MPO to 3x12(8) fiber MPO
Universal
2160639-5
318108AE 12/13 www.te.com/enterprise-asia
13
MPO/MPOptimate System
24 Fiber MPOptimate System
40Gb/s Cassette – 2x24 fiber MPO to
6x12 (8) fiber MPO connectors
1. MPO/MPOptimate System
FEATURES:
• Quick-Fit design, fits in all UCP products
• OM4 bend insensitive fiber
• Cassette attenuation: typical 0.36dB/max. 0.5dB
• Cassette Return Loss: 27dB min
ORDERING INFORMATION
Description
Wire map
Part Number
2x24 fiber MPO to 6x12(8) fiber MPO
Universal
2160649-5
Description
Wire map
Part Number
1x24 fiber MPO to 1x24 fiber MPO
Polarity A
2160650-5
1x24 fiber MPO to 1x24 fiber MPO
Polarity B
1-2160650-5
Description
Wire map
Part Number
2x24 fiber MPO to 2x24 fiber MPO
Polarity A
2160651-5
2x24 fiber MPO to 2x24 fiber MPO
Polarity B
1-2160651-5
100Gb/s Cassette – 1x24 fiber MPO to
1x24 fiber MPO connector
FEATURES:
• Quick-Fit design, Fits in all UCP products
• OM4 bend insensitive fiber
• Cassette attenuation: typical 0.36dB/max. 0.5dB
• Cassette Return Loss: 27dB min
ORDERING INFORMATION
100Gb/s Cassette – 2x24 fiber MPO to
2x24 fiber MPO connectors
FEATURES:
• Quick-Fit design, fits in all UCP products
• OM4 bend insensitive fiber
• Cassette attenuation: typical 0.36dB/max. 0.5dB
• Cassette Return Loss: 27dB min
ORDERING INFORMATION
14
www.te.com/enterprise-asia 12/13 318108AE
MPO/MPOptimate System
24 Fiber MPOptimate System
MPOptimate 24f patch cords
1. MPO/MPOptimate System
FEATURES
• For direct connection of 100G trancievers
• Construction suited to inter-cabinet patching
• Low loss MPOptimate 24 fiber
MPO round 3.8mm cable patch cord
• OM3 and OM4 cable performance, LSZH construction
• Connector performance for OM3/OM4:
Attenuation ≤ 0.25 dB (max.); RL ≥ 28 dB (min)
• All products with protocol, for constant and reliable quality
• Available in female/female type A (straight) wiring
Color: aqua
LENGTH TABLE:
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
9- -0
0,5
9- -5
5,5
1- -1
11
2- -1
21
3- -1
31
4- -1
41
5- -1
51
6- -1
61
7- -1
71
0- -1
1,0
0- -6
6,0
1- -2
12
2- -2
22
3- -2
32
4- -2
42
5- -2
52
6- -2
62
7- -2
72
9- -1
1,5
9- -6
6,5
1- -3
13
2- -3
23
3- -3
33
4- -3
43
5- -3
53
6- -3
63
7- -3
73
0- -2
2,0
0- -7
7,0
1- -4
14
2- -4
24
3- -4
34
4- -4
44
5- -4
54
6- -4
64
7- -4
74
9- -2
2,5
9- -7
7,5
1- -5
15
2- -5
25
3- -5
35
4- -5
45
5- -5
55
6- -5
65
7- -5
75
0- -3
3,0
0- -8
8,0
1- -6
16
2- -6
26
3- -6
36
4- -6
46
5- -6
56
6- -6
66
7- -6
76
9- -3
3,5
9- -8
8,5
1- -7
17
2- -7
27
3- -7
37
4- -7
47
5- -7
57
6- -7
67
7- -7
77
0- -4
4,0
0- -9
9,0
1- -8
18
2- -8
28
3- -8
38
4- -8
48
5- -8
58
6- -8
68
7- -8
78
9- -4
4,5
9- -9
9,5
1- -9
19
2- -9
29
3- -9
39
4- -9
49
5- -9
59
6- -9
69
7- -9
79
0- -5
5,0
1- -0
10
2- -0
20
3- -0
30
4- -0
40
5- -0
50
6- -0
60
7- -0
70
8- -0
80
ORDERING INFORMATION
Description
Part Number
24 fiber; OM4; Straight A wiring;
Y-2160304-X
24 fiber; OM3; Straight A wiring;
Y-2160305-X
318108AE 12/13 www.te.com/enterprise-asia
15
MPO/MPOptimate System
24 Fiber MPOptimate System
40GbE to 10GbE Fan-Out cords –
12 fiber MPO to 4xLC duplex (Fan-Out)
1. MPO/MPOptimate System
FEATURES:
• MPO side connects to 40G QSFP
transceiver, LC side connects to 10G SPF+ (channel)
• Wire map: LC 1-MPO fiber 1-12, LC2-MPO fiber 2-11,
LC3-MPO fiber 3-10, LC4-MPO fiber 4-9
• 8 fiber 3,2/2,0mm diameter
• OM4 bend insensitive fiber LSZH cable
• Flammability IEC 60332 Parts 1 & 3
Color: Aqua
LENGTH TABLE:
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
9- -0
0,5
9- -5
5,5
1- -1
11
2- -1
21
3- -1
31
4- -1
41
5- -1
51
6- -1
61
7- -1
71
0- -1
1,0
0- -6
6,0
1- -2
12
2- -2
22
3- -2
32
4- -2
42
5- -2
52
6- -2
62
7- -2
72
9- -1
1,5
9- -6
6,5
1- -3
13
2- -3
23
3- -3
33
4- -3
43
5- -3
53
6- -3
63
7- -3
73
0- -2
2,0
0- -7
7,0
1- -4
14
2- -4
24
3- -4
34
4- -4
44
5- -4
54
6- -4
64
7- -4
74
9- -2
2,5
9- -7
7,5
1- -5
15
2- -5
25
3- -5
35
4- -5
45
5- -5
55
6- -5
65
7- -5
75
0- -3
3,0
0- -8
8,0
1- -6
16
2- -6
26
3- -6
36
4- -6
46
5- -6
56
6- -6
66
7- -6
76
9- -3
3,5
9- -8
8,5
1- -7
17
2- -7
27
3- -7
37
4- -7
47
5- -7
57
6- -7
67
7- -7
77
0- -4
4,0
0- -9
9,0
1- -8
18
2- -8
28
3- -8
38
4- -8
48
5- -8
58
6- -8
68
7- -8
78
9- -4
4,5
9- -9
9,5
1- -9
19
2- -9
29
3- -9
39
4- -9
49
5- -9
59
6- -9
69
7- -9
79
0- -5
5,0
1- -0
10
2- -0
20
3- -0
30
4- -0
40
5- -0
50
6- -0
60
7- -0
70
8- -0
80
ORDERING INFORMATION
Description
Wire map
Part Number
12 fiber MPO to 4x LC duplex cable.
Special 40/10G
Y-2160510-X
16
www.te.com/enterprise-asia 12/13 318108AE
MPO/MPOptimate System
MPO/MPOptimate Panels & Accessories
Foldable UCP Patch Panel
1. MPO/MPOptimate System
Please refer to Chapter 4, page 45
Foldable UCP Patch Panel Angled
Please refer to Chapter 4, page 45
Angled Quick-Fit Fiber Optic Drawer Panel
FEATURES
• Suitable for Fiber Optic pre-terminated
solution and field direct termination
• 19” 1U unloaded with support for 4 Quick-Fit Modules
• Fully integrated and retractable cable management bracket
• Allows for easy Move, Adds and Changes
• Angled style of panels provides additional cable management
towards side area
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Modular Fiber Optic drawer panel for 4 Quick-Fit modules, angled
1-1671436-1
Flush Quick-Fit Fiber Optic Drawer Panel
FEATURES
• Suitable for Fiber Optic pre-terminated
solution and field direct termination
• 19” 1U unloaded with support for 4 Quick-Fit Modules
• Fully integrated and retractable cable management bracket
• Allows for easy Move, Adds and Changes
• Flushmount
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Modular Fiber Optic drawer panel for 4 Quick-Fit modules, flush
1-1671437-1
318108AE 12/13 www.te.com/enterprise-asia
17
MPO/MPOptimate System
MPO/MPOptimate Panels & Accessories
Quick-Fit Front Plate
1. MPO/MPOptimate System
FEATURES
• Suitable for Copper & Fiber Optic pre-terminated
solution and Copper field direct termination
• Flush mount
• Front plate with no additional cable management
• 19” 1U unloaded with support for 4 Quick-Fit Modules
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Quick-Fit front plate
1427545-1
Quick-Fit Fiber Optic Enclosure
FEATURES
• Suitable for Fiber Optic pre-terminated solution, field direct termination
and splice termination
• 19” enclosure with support for Quick-Fit Modules and splice trays
ORDERING INFORMATION
Description
Part Number
1U Fiber Optic drawer style enclosure for 4 Quick-Fit modules
1933443-1
4U Fiber Optic enclosure for 12 Quick-Fit modules
1553668-1
18
www.te.com/enterprise-asia 12/13 318108AE
MPO/MPOptimate System
MPO/MPOptimate Panels & Accessories
FEATURES
• Quick-Fit module with 6 x or 12 x MPO coupler
• Port number labeling and additional label strip included
• MPO coupler always used with one side MPO male and
other side MPO female connector
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
6 x MPO coupler module
1671200-1
12 x MPO coupler module
1711987-1
MPO/MPOptimate back cable manager
FEATURES
• 19”, 1 U rear cable management bar
• Used for Quick-Fit front plate
• 3 depths available
• Applications include new installation and retrofit
• Rear or front of rack or cabinet mount
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Cable management bar 100 mm depth
1711314-1
Cable management bar 175 mm depth
1711314-2
Cable management bar 275 mm depth
1711314-3
318108AE 12/13 www.te.com/enterprise-asia
19
1. MPO/MPOptimate System
MPO/MPOptimate coupler Quick-Fit module
MPO/MPOptimate System
MPO/MPOptimate Panels & Accessories
MPO/MPOptimate pull protection sleeve
1. MPO/MPOptimate System
FEATURES
• Re-usable installation pull and protection kit
• IP 67 protection
• Must be ordered separately
• One part number contains 1 x installation sleeve with end cap
and 1 x pull sleeve with pull eye
• Does fit to:
– 12 fiber MPO and MPOptimate trunks with midi fan-out
– 24 fiber MPO and MPOptimate trunks with midi fan-out
– 12 x MPO to LC or SC MPO and MPOptimate trunk with midi fan-out
– 48 fiber MPO and MPOptimate trunks with midi fan-out (use 2055567-2)
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Protection sleeve kit for 12 and 24 fiber cables
2055567-1
Protection sleeve kit for 48 fiber cables
2055567-2
Velcro Cable Ties FEATURES
• Hook and loop ties
• Low risk of damaging cables
• Releasable and reusable
• An order quantity of one equals one roll of 10 ties
ORDERING INFORMATION
Description
Part Number
Velcro Tie 1" x 8" (10pcs.)
1375253-2
Velcro Tie 1" x 12" (10pcs.)
1375254-2
20
www.te.com/enterprise-asia 12/13 318108AE
MPO/MPOptimate System
Q3000 Series MPO Fiber Panels
1. MPO/MPOptimate System
Q3000 Series Fiber Panels are the latest innovation in our High Fiber Count
suite of products. The Q3000 Series provides a traditional fiber enclosure to
accommodate applications with high density fiber terminations that require
easy access to individual connectors and cable management within the panel.
The Q3000 series can accommodate LC or MPO applications in singlemode
and multimode fiber types
FEATURES
• Support IEEE 802.3ae, IEEE 802.3ba, IEEE 802.3z
• Exceed ANSI/TIA-568-C.3 and ISO 11801 Edition
2 cabling system requirements
• OM3, OM4 and OS2
• 19-Inch rack mountable
• Available in 1, 2, and 4U Chassis
• 48 Fiber (24 Duplex LC) LC-to-MPO Blade
• 192 Fiber (16 Port) MPO-to-MPO Blade
DIMENSIONS
12.52"
12.52"
12.52"
18.31"
8.7"
18.31"
8.7"
18.31"
8.7"
318108AE 12/13 www.te.com/enterprise-asia
21
MPO/MPOptimate System
Q3000 Series MPO Fiber Panels
Q3200, Q3400 and Q3800 Chassis (unloaded)
1. MPO/MPOptimate System
Q3000 Series base chassis fit it any EIA/TIA 19-inch rack or cabinet. They
can be loaded with any of the Q3000 or Q4000 series blades based on
the application required. An optional door kit can be purchased to provide
additional protection to the fiber patch cords exiting the panel.
ORDERING INFORMATION
Part Number
Product Description
Q3000 series chassis
Front door kits
Blank blade cover
Q3200; 1U (1.75" x 19" x 15"), accommodates 2 blades
QUCH-1RU
Q3400; 2U (3.5" x 19" x 15"), accommodates 4 blades
QUCH-2RU
Q3800; 4U (7" x 19" x 15"), accommodates 8 blades
QUCH-4RU
Q3200; 1U
QDR-1RU
Q3400; 2U
QDR-2RU
Q3800; 4U
QDR-4RU
For covering unused slots in Q3000 or Q4000 Chassis
QBCB-HR
Q3000 Blades
Q3000 Series blades are offered in LC-MPO, and MPO/MPO adapter only in singlemode, OM3 and OM4. These blades
mount in either the Q4000 managed chassis to provide the end-user to upgrade the blade to Q4000 at a later date or
into the standard Q3000 base chassis. Each blade is 1/2U in height (0.875 inches).
LC-MPO Blade
MPO-MPO Blade
ORDERING INFORMATION
Part Number
Product Description
LC to MPO; 24 Duplex LC ports (48 Fibers) distributed
Singlemode LC-MPO blade, pairs straight
from 4 each 12 fiber MPO connectors
OM3 Multimode LC-MPO blade, pairs straight
QUFB-48FDLCMM3HR
MPO to MPO; 16 MPO ports with
Singlemode MPO-MPO blade
QUFB-192FMPOSMHR
12 Fibers each (192 fibers)
OM3/OM4 Multimode MPO-MPO blade
QUFB-192FMPOMMHR
LC to MPO; 24 Duplex LC ports (48 Fibers)
Singlemode LC-MPO blade, pairs straight
QUFB-48FDLCM4ASHR
distributed from 2 each 24 fiber MPO connectors
OM3/OM4 MPOptimate LC-MPO blade, pairs straight
QUFB-48FDLCM4APHR
MPO to MPO; 12 each 8 Fiber MPO
connectors distributed from 4 each 24
fiber MPO connectors (96 fibers)
OM3/OM4 MPOptimate MPOMPO blade, 40GbE wiring
QUFB-96FMM264APHR
22
www.te.com/enterprise-asia 12/13 318108AE
QUFB-48FDLCMSMHR
MPO/MPOptimate System
MPO/MPOptimate Cleaning Tools
ORDERING INFORMATION
Description
Part Number
MTP/MPO with pins; Packaging: 1
1918802-1
1 Slot Reel Cleaner for MPO/LC/SC and MT-RJ; Packaging: 1
1918803-1
2 Slot reel cleaner for LC and SC; Packaging: 1
1918805-1
Cleaner Refill; Packaging: 6 rolls
1918806-1
MPO Coupler Cleaner
ORDERING INFORMATION
Description
Part Number
MPO IBC; Packaging: 1
1918809-1
LC/SC bulkhead cleaner
ORDERING INFORMATION
Description
Part Number
SC IBC (In Bulkhead Cleaner)
2064499-1
LC IBC (In Bulkhead Cleaner)
2064500-1
LC duplex IBC (In Bulkhead Cleaner)
2111664-1
318108AE 12/13 www.te.com/enterprise-asia
23
1. MPO/MPOptimate System
MPO/LC/SC/MT-RJ Cassette Cleaners
24
www.te.com/enterprise-asia 12/13 318108AE
2. MRJ21 System
MRJ21 XG Cassettes & Panels.......................................................................22
MRJ21 XG Trunks................................................................................................23
MRJ21 Cassettes & Panels..............................................................................24
MRJ21 Trunks........................................................................................................26
MRJ21 Fan-Outs..................................................................................................28
MRJ21 Accessories.............................................................................................29
318108AE 12/13 www.te.com/enterprise-asia
25
MRJ21 System
MRJ21 XG Cassettes & Panels
MRJ21 XG Quick-Fit Cassette 8 Port (10 Gb/s)
FEATURES
• Optimal for use in combination with UCP patch
panels: plug & play deployment
• Compatible with MRJ21 XG cable assemblies for 10GbE performance
• Front side: 8 x RJ45 jack (2 rows of 4 jacks)
2. MRJ21 System
• Rear side: 2 x MRJ21 receptacle
• Factory terminated and tested solution
• For AMPTRAC version of MRJ21 XG Quick-Fit cassette
please see page 105 in Chapter 8 Managed Connectivity
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
MRJ21 XG Quick-Fit cassette for 10GBase-T
2153115-1
MRJ21 XG 19” Patch Panel, 1U, straight
FEATURES
• Optimal for use in environments where high density is required
• Factory terminated and tested solution
• Compatible with MRJ21 XG cable assemblies for 10GbE
performance
• Straight panel with either 24 or 48 ports on 1U
• For AMPTRAC version of MRJ21 XG 19” panel
please see page 105 in Chapter 8 Managed Connectivity
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Straight panel 1U for 10GbE; MRJ21 Plugs: 6; RJ-45 Ports: 24
2153041-1
Straight panel 1U for 10GbE; MRJ21 Plugs: 12; RJ-45 Ports: 48
2153046-1
26
www.te.com/enterprise-asia 12/13 318108AE
MRJ21 System
MRJ21 XG Trunks
MRJ21 XG to MRJ21 XG trunks
FEATURES
• ‌Friendly field installable 10 GbE solution
• ‌Factory terminated and 100% tested solution
• ‌Dense double blade connector with offset jackscrews for latching
2. MRJ21 System
• ‌16 pair shielded cable with AWG 26 solid conductors
• ‌Available with LSZH or CMR sheath
Color: white
ORDERING INFORMATION
Y- -X
Length
0- -3
3m
0- -5
5m
1- -0
10 m
1- -5
15 m
2- -0
20 m
2- -5
25 m
3- -0
30 m
Description
Part Number
MRJ21 XG to MRJ21 XG, 10 Gb/s, 180°–180° back shell; LSZH sheath
Y-2153052-X
MRJ21 XG to MRJ21 XG, 10 Gb/s, 180°–45° back shell; LSZH sheath
Y-2153078-X
MRJ21 XG to MRJ21 XG, 10 Gb/s, 180°–180° back shell; CMR sheath
Y-2111521-X
3- -5
35 m
MRJ21 XG to MRJ21 XG, 10 Gb/s, 180°–45° back shell; CMR sheath
Y-2111522-X
4- -0
40 m
Y- -X
Length
0- -3
3m
MRJ21 XG Fan-Out cable to multiple RJ-45 plugs (shielded)
FEATURES
• Friendly field installable 10 GbE solution
• Suitable for use in 3-connector models where 10 GbE application is required
• Factory terminated, 100% tested and serialized
• 16 pair, shielded, AWG 26 solid conductors
• MRJ21 to 4xRJ45 fan-out
ORDERING INFORMATION
Description
Part Number
MRJ21 to 4 RJ-45. 180° back shell; LSZH sheath
Y-2153230-X
318108AE 12/13 www.te.com/enterprise-asia
0- -5
5m
1- -0
10 m
1- -5
15 m
2- -0
20 m
2- -5
25 m
3- -0
30 m
3- -5
35 m
4- -0
40 m
27
MRJ21 System
MRJ21 Cassettes & Panels
MRJ21 Quick-Fit Cassette 12 port (1 Gb/s)
FEATURES
• ‌Pre-terminated Quick-Fit cassette
• ‌High Performance TP Cabling for guaranteed application performance
• ‌High-density, small form factor connectivity
• ‌Modular pluggable solution
2. MRJ21 System
• ‌Automatic bonding by design
ORDERING INFORMATION
Description
Part Number
MRJ21 Quick-Fit cassette for 1000Base-T
1711970-1
MRJ21 angled patch panel (shielded and unshielded)
FEATURES
• High-performance TP cabling for guaranteed application performance
• High-density, small form factor copper connector interface
• Angled panel with 48 ports on 1U
• Factory terminated and tested solution
• Modular, pluggable solution
• Including grounding bolt
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Angled MRJ21 panel for 1000Base-T; MRJ21 Plugs: 8; RJ-45 Ports: 48
1-1671143-1
28
www.te.com/enterprise-asia 12/13 318108AE
MRJ21 System
MRJ21 Cassettes & Panels
MRJ21 patch panel, 1U, straight (shielded)
FEATURES
• High performance TP cabling for guaranteed application performance
• High-density, small form factor copper connector interface
• Factory terminated and tested solution
• Modular pluggable solution
Color: black (RAL 9005) ORDERING INFORMATION
Description
Part Number
Standard straight panel for 1000Base-T; MRJ21 Plugs: 4; RJ-45 Ports: 24
1711944-1
Standard straight panel for 1000Base-T; MRJ21 Plugs: 8; RJ-45 Ports: 48
1777098-1
MRJ21 patch panel, 1U, straight (unshielded)
FEATURES
• High-performance TP cabling for guaranteed application performance
• High-density, small from factor copper connector interface
• Straight panel with 24 or 48 ports on 1U
• Factory terminated and tested solution
• Modular, pluggable solution
Color: black (RAL 9005) ORDERING INFORMATION
Description
Part Number
Standard straight panel for 100Base-T; MRJ21 Plugs: 4; RJ-45 Ports: 48
1435965-1
Standard straight panel for 1000Base-T; MRJ21 Plugs: 8; RJ-45 Ports: 48
1435971-1
Standard straight panel for 1000Base-T; MRJ21 Plugs: 4; RJ-45 Ports: 24
1777029-1
318108AE 12/13 www.te.com/enterprise-asia
29
2. MRJ21 System
• Straight panel with 24 or 48 ports on 1U
MRJ21 System
MRJ21 Trunks
MRJ21 to MRJ21 cable assemblies (shielded)
FEATURES
• Friendly field installable 1 Gbs solution
• Enhanced screening and improved EMC
• Factory terminated and 100 % tested solution
• Dense double blade connector with offset jackscrews for latching
2. MRJ21 System
• 1.5 to 4 times the port density of 2 x 6 Stacked Mod Jack (RJ-45)
• 24 pair shielded cable with AWG 24 solid conductors
Color: white
ORDERING INFORMATION
Y- -X
Length
0- -5
5m
1- -0
10 m
1- -5
15 m
2- -0
20 m
2- -5
25 m
3- -0
30 m
3- -5
35 m
4- -0
40 m
5- -0
50 m
Description
Part Number
MRJ21 to MRJ21, 180°–180° back shell; LSZH sheath
Y-1711758-X
MRJ21 to MRJ21, 180°–45° back shell; LSZH sheath
Y-1711774-X
MRJ21 to MRJ21 cable assemblies (unshielded)
FEATURES
• Factory terminated and tested solution
• Modular, pluggable solution
• Dense CHAMP style double blade design with offset jackscrew
• Contact layout and footprint for differential pairs
creates reduced crosstalk and built-in compensation
• 1.5 to 4 times the port density of 2 x 6 Stacked Mod Jack (RJ-45)
• 3 times the port density of an RJ-21
• Jackscrew for positive latching and secure cable retention
Color: gray
ORDERING INFORMATION
Y- -X
Length
0- -5
5m
1- -0
10 m
1- -5
15 m
2- -0
20 m
2- -5
25 m
3- -0
30 m
3- -5
35 m
4- -0
40 m
5- -0
50 m
Description
Part Number
MRJ-21 to MRJ-21, 180° back shell; CMR sheath
Y-2111366-X
MRJ-21 to MRJ-21, 180°-45° back shell; CMR sheath
Y-2111371-X
30
www.te.com/enterprise-asia 12/13 318108AE
MRJ21 System
MRJ21 Trunks
MRJ21 to MRJ21 ultra slim cable assemblies (unshielded)
FEATURES
• Factory terminated and tested solution
• Modular, pluggable solution
• Dense CHAMP style double blade design with offset screw fixing
2. MRJ21 System
• Improves uptime and space efficiency on site
• 9,2mm cable OD
• 50-60% less cable mass in pathways and spaces
than comparable 4-pair cabling
• 40% less weight than comparable 4-pair cabling
• Gigabit Ethernet Channel performance
• Jackscrews for positive latching and secure cable retention
Color: gray
Y- -X
Length
0- -2
2m
0- -5
5m
1- -0
10 m
1- -5
15 m
2- -0
20 m
2- -5
25 m
3- -0
30 m
ORDERING INFORMATION
Description
Part Number
MRJ21 to MRJ21 , Ultra slim, 180° back shell; CMR sheath
Y-2111367-X
* 30 meters application length restrictions apply
318108AE 12/13 www.te.com/enterprise-asia
31
MRJ21 System
MRJ21 Fan-Outs
MRJ21 Fan-Out cable to multiple RJ-45 plugs (shielded)
FEATURES
• Friendly field installable 1 Gbs solution
• Enhanced screening and improved EMC
• Factory terminated and 100 % tested solution
• Dense double blade connector with offset jackscrews for latching
2. MRJ21 System
• 1.5 to 4 times the port density of 2 x 6 Stacked Mod Jack (RJ-45)
• 24 pair shielded cable with AWG 24 solid conductors
Color: white
Y- -X
Length
0- -5
5m
1- -0
10 m
1- -5
15 m
2- -0
20 m
2- -5
25 m
3- -0
30 m
3- -5
35 m
4- -0
40 m
5- -0
50 m
ORDERING INFORMATION
Description
Part Number
MRJ21 to 6 RJ-45, 180° back shell; LSZH sheath
Y-1711789-X
MRJ21 Fan-Out cable to multiple RJ-45 plugs (unshielded)
FEATURES
• Factory terminated and tested solution
• MRJ21 to RJ45 hydra cable assemblies are wired so that
all 4-pairs of the RJ45 are active for Gigabit Ethernet
• New ergonomic features for easier handling
• Modular, pluggable solution
• Dense CHAMP style double blade design with offset screw fixing
• Contact layout and footprint for differential pairs
creates reduced crosstalk and built-in compensation
• 3 times the port density of an RJ-21
• Jackscrews for positive latching and secure cable retention
• Other lengths on request
Color: gray Y- -X
Length
0- -5
5m
1- -0
10 m
1- -5
15 m
2- -0
20 m
2- -5
25 m
3- -0
30 m
3- -5
35 m
4- -0
40 m
5- -0
50 m
ORDERING INFORMATION
Description
Part Number
MRJ-21 to 6 RJ-45 for 1000Base-T, 180° back shell; CMR sheath
Y-2111370-X
32
www.te.com/enterprise-asia 12/13 318108AE
MRJ21 System
MRJ21 Accessories
Foldable UCP Patch Panel
2. MRJ21 System
Please refer to Chapter 4, page 45
MRJ21 cable guiding shelf
FEATURES
• 19” 4U shelf with 16 vertical slots
• Each slot accepts max. 8 stacks of MRJ21 cable assemblies
• Tie down capability at the back of the shelf
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
MRJ21 cable guiding shelf
1671175-1
318108AE 12/13 www.te.com/enterprise-asia
33
MRJ21 System
MRJ21 Accessories
MRJ21 Back cable manager
FEATURES
• 19”, 1U rear cable management bar
• Used for MRJ21 or other high density copper or fiber optic panels
• Simple on site assembly
• Applications include new installation and retrofit
2. MRJ21 System
• Rear or front of rack or cabinet mount
• 4 depths available
• Tie-down capability on side brackets and back tie-down bar
• Tie-down bar is adjustable for horizontal or vertical cable strain relief
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Back cable manager 6” (150 mm) depth
1933352-1
Back cable manager 9” (230 mm) depth
1933352-2
Back cable manager 12” (300 mm) depth
1933352-3
Back cable manager 16” (400 mm) depth
1933352-4
34
www.te.com/enterprise-asia 12/13 318108AE
3. Sigma-Link Quick Fit System
Sigma-Link Quick-Fit Class FA.....................................................................36
Sigma-Link Quick-Fit Class EA....................................................................37
Sigma-Link Quick-Fit Class E........................................................................38
Sigma-Link Quick-Fit Panel and Accessories........................................39
318108AE 12/13 www.te.com/enterprise-asia
35
Sigma-Link Quick-Fit System
Sigma-Link Quick-Fit Class FA
∑-Link Quick-Fit Cable Assemblies Class FA - PL
FEATURES
• 24 ports per 1U, 6 port links
• Lengths 2-90m
• Factory assembled and 100% tested
• Bundle of 6 x 4 pair solid Category 7A S/FTP cable
(compliant to IEC 61156-5)
• LSFRZH sheath
3. Sigma-Link System
• Three different types of far end termination available
(housing, loose jacks, open cable ends)
Y- -X
Length
0- -2
2m
• Housing-to-Housing version features integrated Plastic Optical Fiber (POF) for easy tracing of far end
0- -5
5m
1- -0
10 m
1- -5
15 m
2- -0
20 m
2- -5
25 m
3- -0
30 m
3- -5
35 m
4- -0
40 m
5- -0
50 m
6- -0
60 m
7- -0
70 m
8- -0
80 m
9- -0
90 m
Termination guidelines for ∑-Link Housing-to-Open end:
Install jacks with tool (TE PN 1725150-1) according to instruction sheet 411-93013.
Use following jacks: AMP-TWIST 7AS
(TE PN 1711437-1 without dustcover or 1711441-1 with dustcover)
Note:
To achieve PL performance cable length should be > 2 m (2 connector model)
according to ISO 11801 spec.
ORDERING INFORMATION
Description
Part Number
Sigma-Link Cable Assembly Housing-to-Housing with POF Class FA STP
Y-2153150-X
Sigma-Link Cable Assembly Housing-to-Jacks Class FA STP
Y-2153151-X
Sigma-Link Cable Assembly Housing-to-Open End Class FA STP
Y-2153152-X
36
www.te.com/enterprise-asia 12/13 318108AE
Sigma-Link Quick-Fit System
Sigma-Link Quick-Fit Class EA
∑-Link Quick-Fit Cable Assemblies Class EA - PL
FEATURES
• 24 ports per 1U, 6 port links
• Lengths 2-90m
• Factory assembled and 100% tested
• Bundle of 6 x 4 pair solid Category 6A F/UTP cable
• LSZH sheath
• Housing-to-Housing version features integrated Plastic Optical Fiber (POF)
for easy tracing of far end
Y- -X
Length
0- -2
2m
• Housing-to-Plugs version for service presentation in mobile
Data Centers
0- -5
5m
1- -0
10 m
1- -5
15 m
2- -0*
20 m
2- -5*
25 m
3- -0*
30 m
3- -5*
35 m
4- -0*
40 m
5- -0*
50 m
6- -0*
60 m
7- -0*
70 m
8- -0*
80 m
9- -0*
90 m
Termination guidelines for ∑-Link Housing-to-Open end:
Install jacks with tool (TE PN 1725150-1) according to instruction sheet 411-93016.
Use following jacks: AMP-TWIST 6AS
(TE PN 1711716-1 without dustcover or 1711592-1 with dustcover).
Note:
To achieve PL performance cable length should be > 2 m (2 connector model)
according to ISO 11801 spec.
ORDERING INFORMATION
Description
Part Number
Sigma-Link Cable Assembly Housing-to-Housing with PoF Class EA Shielded
Y-1859622-X
Sigma-Link Cable Assembly Housing-to-Jacks Class EA Shielded
Y-1859623-X
Sigma-Link Cable Assembly Housing-to-Open End Class EA Shielded
Y-1859624-X
Sigma-Link Cable Assembly Housing-to-Plugs Class EA Shielded
(Only available up to 15 m! Shorter lengths between increments on request.)
Y-1859625-X
318108AE 12/13 www.te.com/enterprise-asia
* not applicable for
Housing-to-Plugs
version
37
3. Sigma-Link System
• Four different types of far end termination available
(housing, loose jacks, open cable ends, loose plugs)
Sigma-Link Quick-Fit System
Sigma-Link Quick-Fit Class E
∑-Link Quick-Fit Cable Assemblies Class E - PL
FEATURES
• 24 ports per 1U, 6 port links
• Lengths 2-90m
• Factory assembled and 100% tested
• Bundle of 6 x 4 pair solid Category 6 U/UTP Cable
• LSZH Sheath
• Three different types of far end termination available
(housing, loose jacks, open cable ends)
3. Sigma-Link System
• Housing-to-Housing version features integrated
Plastic Optical Fiber (POF) for easy tracing of far end
Y- -X
Length
0- -2
2m
0- -5
5m
Termination guidelines for ∑-Link Housing-to-Open end:
1- -0
10 m
Install jacks with tool (TE PN 1725150-1) according to instruction sheet 408-8858
Use following jacks: Cat 6 RJ45 SL 110 connect
(TE PN 1375055-X without dustcover or 1375187-X with dustcover)
1- -5
15 m
2- -0
20 m
2- -5
25 m
3- -0
30 m
Note:
3- -5
35 m
To achieve PL performance cable length should be > 2 m (2 connector model)
according to ISO 11801 spec.
4- -0
40 m
5- -0
50 m
6- -0
60 m
7- -0
70 m
8- -0
80 m
9- -0
90 m
ORDERING INFORMATION
Description
Part Number
Sigma-Link Cable Assembly Housing-to-Housing with POF Class E UTP
Y-2153140-X
Sigma-Link Cable Assembly Housing-to-Jacks Class E UTP
Y-2153141-X
Sigma-Link Cable Assembly Housing-to-Open End Class E UTP
Y-2153142-X
38
www.te.com/enterprise-asia 12/13 318108AE
Sigma-Link Quick-Fit System
Sigma-Link Quick-Fit Panel and Accessories
Foldable UCP Patch Panel Angled and Flushmount
3. Sigma-Link System
Please refer to Chapter 4, page 45
∑-Link identifier lamp
FEATURES
• Identifies the far end of the installed link
• Easy mounting on the housings
ORDERING INFORMATION
Description
Part Number
Sigma-Link identifier lamp; blue LED
1-1671330-1
318108AE 12/13 www.te.com/enterprise-asia
39
40
www.te.com/enterprise-asia 12/13 318108AE
4. Mixed Media Platform
XDS Cabinet and Rack System
Rack................................................................................................................ 42
Accessory..................................................................................................... 43
Universal Connectivity Platform
UCP & Xtra-U Patch Panels.................................................................. 45
UCP Xtra-U Mounting Accessories.....................................................47
318108AE 12/13 www.te.com/enterprise-asia
41
XDS Cabinet and Rack System
XDS Server Racks
XDS Server Racks
TE's XDS Server Racks are designed for high density data centers with advanced
cooling, cable management and power distribution features that keep critical
servers and network equipment operating nonstop.
FEATURES
• Integrated Vertical Cable Managers for 800 Series Racks – help
to maintain the proper bend radius of the patch cords
• Material: cold rolled steel, compliant with RoHS standard. The frame is made
of 2mm powder coated steel, ensuring a rigid, durable and rustproof cabinet.
• Front door: Curved steel door with 70% perforation, 4.8mm
diameter perforation. Lockable for security.
4. Mixed Media Platform
• Back doors: 2 flat panes perforated steel doors, 4.8mm
diameter perforation. Lockable turn lock.
• Adjustable mounting rails.
• Removable and reversible front door; allow the door
to open from either the left or the right.
• Removable side panels.
• Heavy duty casters to help position the rack to final position.
Adjustable leveling feet to secure the position.
• Cable routing from top and bottom. Cable entries
covered with removable blanking plates.
• Static load up to 1000 Kg.
• Grounding system: all metallic parts are bonded with grounding cable kits.
• Modular knocked-down/flat-packed units. To be assembled
on-site to save storage space and ease of transportation.
• Accessory: 50 pcs of M6 screws, cage nuts and plastic washers
• Color : Black powder coated (RAL9005)
PRODUCT SELECTION
Description
UH
Standard Rack 600 Series (W x D)
Standard Rack 800 Series
(W x D)
600 x 600
600 x 800
600 x 1100
800 x 800
800 x 1100
Standard Rack 42U
42
1427543-1
1427490-1
1427560-1
1427491-1
1427561-1
Standard Rack 42U, w/o Side Panels
42
1427543-2
1427490-2
1427560-2
1427491-2
1427561-2
Integrated Vertical Cable Managers
for 800 Series Racks for Reference
42
www.te.com/enterprise-asia 12/13 318108AE
XDS Cabinet and Rack System
Rack Accessory
Vented Shelf 400 MM Deep FEATURES
• Supports equipment up to 400 mm. deep, with 1U height
• Compatible with 19" Racks
• Material: cold rolled steel plate, 1.5mm complies with RoHS standard
• Up to 15 kg load capacity, able to take the weight of
equipment such as Modem, Power Adapter etc
ORDERING INFORMATION
Description
Part Number
1427509-1
4. Mixed Media Platform
Vented Shelf 400 mm Depth
Fixed Shelf
FEATURES
• Fixed and Heavy Duty Shelves are ideal for heavy equipment
• Compatible with 19" Racks, 1U height. Mounting hardware included
• Material: cold rolled steel plate, complies with RoHS standard
• 80 Kg load capacity for Fixed Shelf series, 1.5mm thickness
• Compatible with 800 and 1100 deep cabinets
ORDERING INFORMATION
Description
Part Number
Fixed Shelf, for 1100mm Depth Racks
1427573-1
Fixed Shelf, for 800mm Depth Racks
1427493-1
Sliding Shelf
FEATURES
• Slides out for easy access to equipment
• Compatible with 19" Racks, 1U height. Mounting hardware included
• Material: cold rolled steel plate, 1.5mm complies with RoHS standard
• 40 Kg load capacity
• Compatible with 800 and 1100 deep cabinets
ORDERING INFORMATION
Description
Part Number
Sliding Shelf, for 1100mm Depth Racks
1427574-1
Sliding Shelf, for 800mm Depth Racks
1427494-1
318108AE 12/13 www.te.com/enterprise-asia
43
XDS Cabinet and Rack System
Rack Accessory
Cable Management FEATURES
• Mounted on the top of XDS Racks to mange cable routing between racks
• Material: cold rolled steel plate, 1.5mm complies with RoHS standard
• Black powder coated
ORDERING INFORMATION
Description
Part Number
Rack Top Cable Trough
1427578-1
Brush Panels
4. Mixed Media Platform
FEATURES
• Blank panels with brushed opening
• Allow cable to route to the rear of the rack while minimizing by-pass cold air
• Material: cold rolled steel plate, 1.5mm compliant with RoHS standard.
• Made from black powder coated steel
ORDERING INFORMATION
Description
Part Number
Blank Panel – 1U
1427577-1
1U Cable Management Module
FEATURES
• Cable Manager to facilitate proper patch cord management
• Material: cold rolled steel plate, 1.5mm compliant with RoHS standard
• Made from black powder coated steel
ORDERING INFORMATION
Description
Part Number
1U Cable Management Module
1427632-2
Mounting Hardware
FEATURES
• Hardware to attach panels and equipment to racks and cabinets
• M6 screws, Cage nuts and Washer kits
• Package quantity: 50 sets
ORDERING INFORMATION
Description
Part Number
M6 Screws, cage nuts and washers, (50 sets per pack)
44
1427495-1
www.te.com/enterprise-asia 12/13 318108AE
Universal Connectivity Platform
UCP & Xtra-U Patch Panels
Foldable UCP Patch Panel
FEATURES
• Foldable 19” 1U unloaded modular patch panel
with support for 4 UCP modules
• Flush style panel
• Modular, rear cable management for both
horizontal Copper and Fiber cables
• Accepts Pre-terminated Cu or FO cassettes
or Field-terminated Copper modules
• Including grounding bolt
Color: black (RAL 9005)
Description
4. Mixed Media Platform
ORDERING INFORMATION
Part Number
UCP Patch Panel, 1U Flushmount, Foldable
1427544-1
Foldable UCP Patch Panel Angled
FEATURES
• Foldable 19” 1U unloaded modular patch panel
with support for 4 UCP modules
• Angled style panel
• Modular, rear cable management for both
horizontal Copper and Fiber cables
• Accepts Pre-terminated Cu or FO cassettes
or Field-terminated Copper modules
• Including grounding bolt
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Foldable UCP Patch Panel 1U Angled
Part Number
1427592-1
318108AE 12/13 www.te.com/enterprise-asia
45
Universal Connectivity Platform
UCP & Xtra-U Patch Panels
Xtra-U Fiber Panel with Cable Management
FEATURES
• 3U Bracket to support a single MPOptimate Quick-Fit cassette
• Management rings to store and protect
excess MPOptimate trunk cables
• Including grounding bolt
ORDERING INFORMATION
Description
Part Number
Xtra-U Fiber Panel with Cable
Management (for standard racks)
1-1671547-1
4. Mixed Media Platform
Xtra-U Copper Panel without Cable Management
FEATURES
• 3U Bracket to support a single Copper Quick-Fit cassette
or module
• Including grounding bolt
ORDERING INFORMATION
Description
Part Number
Xtra-U Copper Panel without Cable
Management (for standard racks)
1-1671548-1
Xtra-U Vertical Panel Mounting Brackets
FEATURES
• Bracket set to install a 1U 19” panel vertically
outside of the 19” area of a cabinet/rack
• Available for 1U
ORDERING INFORMATION
Description
Part Number
Xtra-U Vertical Panel Mounting Brackets (2 pcs)
(for standard racks)
1-1671549-1
46
www.te.com/enterprise-asia 12/13 318108AE
Universal Connectivity Platform
UCP Xtra-U Mounting Accessories
Xtra-U Subfloor Panel Holder Kit
FEATURES
• Bracket set to install 19” panels in the false
floor area underneath cabinets/racks
• Suitable for Copper and Fiber installations
• Allows up to 630mm gap between support pillars
• Attachable to support pillars with round or square
cross-section (diameters from 14 to 30mm)
• Available for 1, 2 or 4U
ORDERING INFORMATION
Part Number
Xtra-U Subfloor Panel Holder Kit 1U
1671189-1
Xtra-U Subfloor Panel Holder Kit 2U
1671189-2
Xtra-U Subfloor Panel Holder Kit 4U
1671189-4
4. Mixed Media Platform
Description
Xtra-U Aerial Panel Holder Kit for Wire Mesh Cable Trays
and FiberGuide System
FEATURES
• Universal bracket for installing 9” patch panels above
cabinets / racks
• Can be attached to FGS channels (4x4, 4x6 and 4x12)
• 2U and 4U version available
ORDERING INFORMATION
Description
Part Number
Xtra-U Aerial Panel Holder Kit, 1U
1-1671603-1
Xtra-U Aerial Panel Holder Kit, 2U
1-1671603-2
Xtra-U Aerial Panel Holder Kit (2U) for FGS
1-1671603-3
Xtra-U Aerial Panel Holder Kit (4U) for FGS
1-1671603-4
318108AE 12/13 www.te.com/enterprise-asia
47
Universal Connectivity Platform
UCP Xtra-U Mounting Accessories
Xtra-U FiberGuide System Quick-Fit adaptor
FEATURES:
• Fits to FGS products, s.a. 4” Express Exits, 4 x 4 Downspouts
• Can accommodate up to 2 Quick-Fit MPO cassettes or modules
• Integrated strain relief feature
• Including grounding bolt
Color: galvanized
ORDERING INFORMATION
4. Mixed Media Platform
Description
Part Number
Xtra-U FGS Quick-Fit adaptor
1-1671618-1
48
www.te.com/enterprise-asia 12/13 318108AE
5. FiberGuide System
4x4 System
Fittings ..................................................................................................................50
Downspouts and Attachments .................................................................. 52
Straight Section and Snap-Fit™ Junction ..............................................54
Part Drawings...................................................................................................... 55
2x6 System
Fittings, Downspouts and Attachments ................................................ 58
Straight Section and Junction ....................................................................60
Part Drawings....................................................................................................... 61
4x6 System
Fittings .................................................................................................................. 63
Downspouts and Attachments .................................................................. 65
Straight Section and Snap-Fit™ Junction .............................................. 67
Part Drawings......................................................................................................68
4x12 System
Fittings ..................................................................................................................70
Downspouts and Attachments .................................................................. 72
Straight Section ................................................................................................ 74
Snap-Fit™ Junction .......................................................................................... 75
Part Drawings...................................................................................................... 76
4x24 System
Fittings – 4" H x 24" W................................................................................... 79
Downspouts – 4" H x 24" W.........................................................................80
Straight Section, Snap-Fit™ Junctions and covers ............................. 81
Part Drawings...................................................................................................... 82
Express Exit™ Family
For 4x4, 4x6 and 4x12 Systems..................................................................84
Part Drawings......................................................................................................86
System Support Kits
For 2x6, 4x4 and 4x6 Systems................................................................... 87
For 4x12 Systems............................................................................................... 88
For 4x24 Systems............................................................................................. 89
System Accessories..........................................................................................90
318108AE 12/13 www.te.com/enterprise-asia
49
4x4 System
Fittings – 4" H x 4" W
The FiberGuide fiber management system is a UL-listed (E151158)
general purpose fiber optic raceway system. All FiberGuide
products are manufactured from flame-retardant materials. No
FiberGuide system parts contain PVC.
5. FiberGuide System
Horizontal T
Horizontal Cross
90° Horizontal Elbow
(FGS-MHRT-A)
(FGS-MHXP-A)
(FGS-MH9E-A)
90° Up Elbow
90° Down Elbow
45° Horizontal Elbow
Metal Cover Included
(FGS-MD9E-A)
(FGS-MH4E-A)
45° Up Elbow
45° Down Elbow
4x4 to 4x6 Straight Adapter
Metal Cover Included
(FGS-MU4E-A)
(FGS-MD4E-A)
(FGS-MDSA-AB)
(FGS-MU9E-A)
Expandable Straight Section
Cut-in T
Cut-in T Fixture
(FGS-MVAR-A)
(FGS-MHIS-A)
shown on straight section
(FGS-MHIS-JIG-A/B/F)
50
End Cap
Snap-on Plastic Cover
(FGS-HMEC-A)
(FGS-SH4E-A shown attached to 45°
horizontal elbow with junctions)
www.te.com/enterprise-asia 12/13 318108AE
4x4 System
Fittings – 4" H x 4" W
ORDERING INFORMATION
Part Number
Description
Number
of
Junctions
Yellow System
Yellow
System
Snap-on Cover
Black System
Black
System
Snap-on
Cover
Fixed
Metal Cover
Horizontal T
3
FGS-MHRT-A
FGS-SHRT-A
FGSB-MHRT-A
FGSB-SHRT-A
FGS-CHRT-A
Horizontal cross
4
FGS-MHXP-A
FGS-SHXP-A
FGSB-MHXP-A
FGSB-SHXP-A
FGS-CHXP-A
90° horizontal
elbow
2
FGS-MH9E-A
FGS-SH9E-A
FGSB-MH9E-A
FGSB-SH9E-A
FGS-CH9E-A
90° up elbow
metal cover
included
2
FGS-MU9E-A
FGS-SU9E-A
FGSB-MU9E-A
FGSB-SU9E-A
–
90° down elbow
2
FGS-MD9E-A
FGS-SD9E-A
FGSB-MD9E-A
FGSB-SD9E-A
FGS-CD9E-A
45° horizontal
elbow
2
FGS-MH4E-A
FGS-SH4E-A
FGSB-MH4E-A
FGSB-SH4E-A
FGS-CH4E-A
45° up elbow
metal cover
included
2
FGS-MU4E-A
FGS-SU4E-A
FGSB-MU4E-A
FGSB-SU4E-A
–
45° down elbow
2
FGS-MD4E-A
FGS-SD4E-A
FGSB-MD4E-A
FGSB-SD4E-A
FGS-CD4E-A
FGS-MDSA-AB
FGS-SDSA-AB
FGSB-MDSA-AB
FGSB-SDSA-AB
FGS-CDSA-AB
4x4 conversions
4x4 to 4x6
straight adapter
(1) 4x4,
(1) 4x6
4x4 expandable
straight section
2
FGS-MVAR-A
–
FGSB-MVAR-A
–
–
4"Cut-in T
assembly
hardware included
–
FGS-MHIS-A
–
FGSB-MHIS-A
–
–
6"Cut-in T
assembly
hardware included
–
FGS-MHIS-B
–
FGSB-MHIS-B
–
–
12"Cut-in T
assembly
hardware included
–
FGS-MHIS-F
–
FGSB-MHIS-F
–
–
–
FGS-MHISJIG-A/B/F
–
FGS-MHISJIG-A/B/F
–
–
–
FGS-HMEC-A
–
FGS-HMEC-A
–
–
Cut-in T fixture
4x4 end cap
318108AE 12/13 www.te.com/enterprise-asia
51
5. FiberGuide System
4x4 fittings
4x4 System
Downspouts and Attachments – 4" H x 4" W
5. FiberGuide System
Downspout
Cover for 4x4 Downspout
Extended Downspout
(FGS-MDSP-A)
(FGS-MCDS-AB)
(FGS-MDSP-EX-A
shown with and without cover)
Insertable Downspout
Trumpet Flare
(FGS-MDSP-A/I)
(FGS-MTRM-A)
Downspout Exit
Junction Kit
4x4/4x6 Downspout Insert
(FGS-HDSI-AB)
4" Square to 2" Round Adapter
with Flex Tube
Single 2" Flex Tube Attachment
2" Quad Flex Tube Attachment
(FGS-KT03-A1)
(FGS-KT03-A4)
52
(FGS-ASRI requires
FGS-MJWR-A Junction Kit)
(FGS-MJWR-A)
Dual 2" Flex Tube Attachment
(FGS-KT03-A)
www.te.com/enterprise-asia 12/13 318108AE
4x4 System
Downspouts and Attachments – 4" H x 4" W
An array of 4x4 downspout options are available to feed fiber from
overhead straight sections into fiber optic equipment below.
ORDERING INFORMATION
Part Number
Number of
Junctions
Description
Yellow System
Black System
Downspout
2**
FGS-MDSP-A
FGSB-MDSP-A
FGS-MCDS-AB
FGSB-MCDS-AB
Cover for 4x4 downspout
–
Extended downspout
2*
FGS-MDSP-EX-A
FGSB-MDSP-EX-A
Cover for 4x4 extended downspout
–
FGS-MCDS-EX-AB
FGSB-MCDS-EX-AB
Insertable downspout
–
FGS-MDSP-A/I
FGSB-MDSP-A/I
Trumpet flare used on both 4x4 and 4x6
downspouts; no 4" junction kit required
–
FGS-MTRM-A
FGSB-MTRM-A
Downspout exit junction kit
–
FGS-MJWR-A
FGSB-MJWR-A
4x4/4x6 downspout; insert converts bottom of downspout to
2x2" without using 2" to 4" adapter, saving vertical space
–
FGS-HDSI-AB
FGS-HDSI-AB
4x4 attachments
Square to 2" round adapter with flex tube;
one 4x4 junction kit (FGS-MJWR-A) required to attach to a downspout drop
5' length
1
FGS-ASRI-5F
FGSB-ASRI-5F
10' length
1
FGS-ASRI-10F
FGSB-ASRI-10F
15' length
1
FGS-ASRI-15F
FGSB-ASRI-15F
(2) 5' length
–
FGS-KT03-A
FGSB-KT03-A
(2) 10' length
–
FGS-KT03-A10F
FGSB-KT03-A10F
(2) 15' length
–
FGS-KT03-A15F
FGSB-KT03-A15F
Dual 2" flex tube attachment; no 4x4 junction kit required
Single 2" flex tube attachment; no 4x4 junction kit required
5' length
–
FGS-KT03-A1
FGSB-KT03-A1
10' length
–
FGS-KT03-A1-10F
FGSB-KT03-A1-10F
15' length
–
FGS-KT03-A1-15F
FGSB-KT03-A1-15F
(4) 5' length
–
FGS-KT03-A4-5F
FGSB-KT03-A4-5F
(4) 10' length
–
FGS-KT03-A4-10F
FGSB-KT03-A4-10F
(4) 15' length
–
FGS-KT03-A4-15F
FGSB-KT03-A4-15F
Quad 2" flex tube attachment; no 4x4 junction kit required
4x4 quad 7/8" flex tube attachment; no 4x4 junction kit required
(4) 5' length
–
FGS-KT07-A4-5F
FGSB-KT07-A4-5F
(4) 10' length
–
FGS-KT07-A4-10F
FGSB-KT07-A4-10F
(4) 15' length
–
FGS-KT07-A4-15F
FGSB-KT07-A4-15F
*A third junction is needed if drop is to a fitting or straight section.
**This drop junction must be a junction type FGS-MJWR-A, FGSB-MJWR-A.
318108AE 12/13 www.te.com/enterprise-asia
53
5. FiberGuide System
4x4 downspouts
4x4 System
Straight Section and Snap-Fit™ Junction – 4" H x 4" W
Straight Section
The unique four-channel design of the 4x4 FiberGuide straight
section allows the standard system to be attached to the support
structure without the need to cut or drill any holes within the
trough. This ensures that the patch cords will not come in contact
with any screw heads or bolts, an important consideration in 4x4
systems where higher cable counts apply increased pressure on
patch cords at the bottom of the trough.
Horizontal
Straight Section
Expandable
Straight Section
Hinged Cover for
Horizontal Straight Section
(FGS-MSHS-A)
(FGS-MVAR-A)
(FGS-MSNC-A)
5. FiberGuide System
Snap-On
Cover for Horizontal
Straight Section
(FGS-MSSC-A)
ORDERING INFORMATION
Part Number
Description
Yellow System
Black System
Horizontal straight section; 6' long, cover sold seperately
FGS-MSHS-A
FGSB-MSHS-A
Expandable straight section
FGS-MVAR-A
FGSB-MVAR-A
Hinged cover kit for horizontal straight section;
includes three mounting hinges and three clips
FGS-MSNC-A
FGSB-MSNC-A
Snap-on cover kit for horizontal straight section;
includes six capture clips with mounting clasps
FGS-MSSC-A
FGSB-MSSC-A
FGS-DHCP
FGS-DHCP
FGS-DHHC
(Yellow Hinge)
FGSB-DHHC
(Black Hinge)
4x4 straight section
4x4 accessories
Kit - 10 black capture clips
Kit - 10 black capture clips and 10 hinges
Snap-Fit™ Junction
The Snap-Fit™ junction assembly is available for the 4-inch
FiberGuide system. The Snap-Fit junction is a completely toolless junction. No additional tools are required for installation
or removal. The junction exhibits superior holding force and
accommodates support brackets. A warning label indicating
caution around fiber optic cable is included with each junction kit.
Snap-Fit Junction
(FGS-MFAW-A)
ORDERING INFORMATION
Part Number
Description
4x4 Snap-Fit™ junction
54
www.te.com/enterprise-asia 12/13 318108AE
Yellow System
Black System
FGS-MFAW-A
FGSB-MFAW-A
4x4 System
Part Drawings
330 mm
(13")
330 mm
(13")
Top
330 mm
(13")
Top
102 mm
(4")
102 mm
(4")
112 mm
(4.4"
112 mm
(4.4"
Front
Front
Horizontal T
(FGS-MHRT-A)
Horizontal Cross
(FGS-MHXP-A)
237 mm (9.3")
237 mm
(9.3")
120 mm
(4.7")
260 mm
(10.2")
165 mm
(6.5")
R 51 mm
(2")
Top
218 mm
(8.6")
Side
102 mm (4")
112 mm (4.4
End
Junction Detail
(Not Included)
218 mm
(8.6")
End
90° Horizontal Elbow
(FGS-MH9E-A)
90° Up Elbow
(FGS-MU9E-A)
208 mm
(8.19")
102 mm
(4")
Top
Side
End
144 mm
(5.7")
112 mm
(4.4")
90° Down Elbow
(FGS-MD9E-A)
260 mm
(10.2"
5. FiberGuide System
27 mm
(9.3")
208 mm
(8.2"
223 mm
(8.8")
194 mm
(7.7")
102 mm (4")
112 mm (4.4
End
45° Horizontal Elbow
(FGS-MH4E-A)
318108AE 12/13 www.te.com/enterprise-asia
55
4x4 System
Part Drawings
251 mm (10")
102 mm (4")
Top
163 mm
(6.4")
45°
203 mm
(8")
Junction De
(Not Includ
R 51 mm
(2")
Side
End
203 mm
(8")
166 mm (6.6
Side
124 mm (5")
144 mm
(5.7")
210 mm (8.3")
45° Up Elbow
(FGS-MU4E-A)
112 mm
(4.4")
123 mm
(4.9"
163 mm
(6.4")
45° Down Elbow
(FGS-MD4E-A)
195 mm (7.7"
)
186 mm
(7.3"
)
Top
356 mm
(14")
Retracted Straight Section
144 mm
(5.7"
)
102 mm
5. FiberGuide System
112 mm
(4"
)
(4.4"
)
559 mm
(22")
Expanded Straight Section
Fron
Expandable Straight Section
(FGS-MVAR-A)
4x4 to 4x6 Straight Adapter
(FGS-MDSA-AB)
345.2 mm
(13.6")
254 mm
(10")
159 mm
(6.25")
329 mm
(13")
330 mm
(13")
144 mm
(5.7")
Front
112 mm
(4.4")
Top
102 mm
(4")
102 mm
(4")
144 mm
(5.7")
44 mm
(1.75")
160 mm
(6.3"
305 mm
(12")
Cut-in T
(FGS-MHIS-A)
Downspout
(FGS-MDSP-A)
329 mm
(13")
330 mm
(13")
211 mm
(8.3")
279 mm
(11")
102 mm
(4")
Extended Downspout
(FGS-MDSP-EX-A)
56
133 mm
(5.25")
144 mm
(5.7")
137 mm
(5.4")
330 mm
(13")
Side
End
102 mm
(4")
Straight
Section
Snap-On Cover
for
4" Straight Section
(Not Included)
(FGS-MSSC-A)
www.te.com/enterprise-asia 12/13 318108AE
.625"
(Not Included)
4x4 System
Part Drawings
OPEN
213 mm
(8.4")
76 mm
(3")
Top
103 mm
(4")
211 mm
(8.3"
159 mm (6.25")
End
104 mm
(4.1")
Trumpet Flare
(FGS-MTRM-A)
4x4/4x6 Downspout Insert
(FGS-HDSI-AB)
116 mm
(4.6")
144 mm (5.7")
144 mm
(5.7"
)
X
116 mm
(4.55"
183 mm (72")
Dimension
1.52 m (5
3.05 m (1
3.57 m (1
4" Square to 2" Round Adapter
Horizontal Straight Section
(FGS-MSHS-A)
with Flex Tube
(FGS-ASRI-X*)
108 mm
(4.25"
)
159 mm
(6.3")
24 mm
(1")
137 mm
(5.4")
173 mm
(6.8"
)
179 mm
mm
102
(7") )
(4.0"
End
Side
Side
End
102 mm
(4")
117 mm
(4.6")
102 mm
(4")
5. FiberGuide System
51 mm (2")
CLOSE
R 51 mm (2")
143 mm
140
mm
(5.6")
(5.51"
)
Straight Section
(Not Included)
102 mm
(4")
Hinged Cover for 4" Horizontal
Straight Section
Snap-Fit Junction
(FGS-MFAW-A)
(FGS-MSNC-A)
*Replace X with tube length as follows: 5F=5 feet, 10F=10 feet, 15F=15 feet
318108AE 12/13 www.te.com/enterprise-asia
57
2x6 System
Fittings, Downspouts and Attachments – 2" H x 6" W
5. FiberGuide System
2x6 to 2x2 Downspout
Horizontal T
Horizontal Cross
(FGS-MDSP-G)
(FGS-MHRT-G)
(FGS-MHXP-G)
90° Horizontal Elbow
90° Down Elbow
45° Horizontal Elbow
(FGS-MH9E-G)
(FGS-MD9E-G)
(FGS-MH4E-G)
45° Up Elbow
45° Down Elbow
2x6 to 4x4 Adapter
(FGS-MU4E-G)
(FGS-MD4E-G)
(FGS-MDSA-GA)
(Metal Cover Included)
58
2x6 to 4x6 Adapter
Trumpet Flare
(FGS-MDSA-GB)
(FGS-MTRM-G)
www.te.com/enterprise-asia 12/13 318108AE
2x6 System
Fittings, Downspouts and Attachments – 2" H x 6" W
ORDERING INFORMATION
Part Number
Number of
Junctions
Description
Yellow System
Black System
2x6 fittings
Horizontal T
3
FGS-MHRT-G
FGSB-MHRT-G
Horizontal cross
4
FGS-MHXP-G
FGSB-MHXP-G
90° horizontal elbow
2
FGS-MH9E-G
FGSB-MH9E-G
90° down elbow
2
FGS-MD9E-G
FGSB-MD9E-G
45° horizontal elbow
2
FGS-MH4E-G
FGSB-MH4E-G
45° up elbow, metal cover included
2
FGS-MU4E-G
FGSB-MU4E-G
45° down elbow
2
FGS-MD4E-G
FGSB-MD4E-G
2x6 conversions
2x6 to 4x4 adapter
(1) 2x6, (1) 4x4
FGS-MDSA-GA
FGSB-MDSA-GA
2x6 to 4x6 adapter
(1) 2x6, (1) 4x6
FGS-MDSA-GB
FGSB-MDSA-GB
–
FGS-MTRM-G
FGSB-MTRM-G
2
FGS-MDSP-G
FGSB-MDSP-G
Dual 2" flex tube attachment
–
FGS-KT03-G-5F
FGSB-KT03-G-5F
2x6 end cap
–
FGS-HMEC-G
FGS-HMEC-G
Trumpet flare
2x6 to 2x2 downspout
2x6 attachments
Low-Profile Express Exit™
Designed for low-ceiling or height restricted environments,
the Express Exit™ for the 2x6 FiberGuide system extends only
two inches above the straight section sidewall. The Express
Exit accommodates up to 150 (3 mm) patch cords, includes
removable rear cable guides for additional cable management,
and features a 2x2 exit opening. It is designed specifically
for the 2x6 FiberGuide system and should not be used on
any other FiberGuide system.
Express Exit
(FGS-MEXP-LP-G)
ORDERING INFORMATION
Part Number
Description
Low-Profile Express Exit™ (designed exclusively for the 2x6 system)
Base, cover, mounting hardware, and support bracket included
Yellow System
Black System
FGS-MEXP-LP-G
FGSB-MEXP-LP-G
318108AE 12/13 www.te.com/enterprise-asia
59
5. FiberGuide System
2x6 downspouts
2x6 System
Straight Section and Junction – 2" H x 6" W
Straight Section
The unique four-channel design of the 2x6 FiberGuide straight
section allows the standard system to be attached to the
support structure without the need to cut or drill any holes
within the trough. This ensures that the patch cords will not
come in contact with any screw heads or bolts.
Straight Section
(FGS-MSHS-G)
Hinged Cover Kit for Horizontal
Straight Section
(FGS-MSNC-B/G)
6-inch Snap-on Cover
(FGS-MSSC-B/G)
ORDERING INFORMATION
5. FiberGuide System
Part Number
Description
Yellow System
Black System
FGS-MSHS-G
FGSB-MSHS-G
2x6 hinged cover kit for horizontal straight section;
three mounting hinges and three clips included
FGS-MSNC-B/G
FGSB-MSNC-B/G
6-inch snap-on cover kit for horizontal straight section;
six capture clips with mounting clasps included
FGS-MSSC-B/G
FGSB-MSSC-B/G
FGS-DHCP
FGS-DHCP
2x6 straight section; horizontal straight section; 6' long, cover sold seperately
2x6 accessories
Kit-10 black capture clips
Junction
The one-piece junction employs factory-installed set screws
to assure strength and durability. No cutting or drilling of
the components is required for assembly. A warning label
indicating caution around fiber optic cable is included with
each junction kit.
2x6 Junction
ORDERING INFORMATION
(FGS-JUNC-G)
Part Number
Description
2x6 junction
60
www.te.com/enterprise-asia 12/13 318108AE
Yellow System
Black System
FGS-JUNC-G
FGSB-JUNC-G
2x6 System
Part Drawings
356 mm
(14")
343 mm
(13.5")
343 mm
(13.5")
343 mm
(13.5")
195 mm
(7.7")
269 mm
(10.6")
51 mm
(2")
14"
(356 mm)
45 mm
(1.75")
152 mm
(6")
45 mm
(1.75")
152 mm
(6")
29 mm
(1.1")
2x6 to 2x2 Downspout
(FGS-MDSP-G)
Horizontal T
(FGS-MHRT-G)
Horizontal Cross
(FGS-MHXP-G)
269 mm
(10.6")
35.6 mm
(1.4")
36 mm
(1.4")
152 mm
(6")
5. FiberGuide System
196 mm
(7.7")
269 mm
(10.6")
152 mm
(6")
45 mm
(1.75")
36 mm
(1.4")
45 mm
(1.75")
145 mm
(5.7")
90º Horizontal Elbow
(FGS-MH9E-G)
36 mm
(1.4")
90º Down Elbow
(FGS-MD9E-G)
231 mm
(9.1")
226 mm
(8.9")
45°
36 mm
(1.4")
196 mm
(7.7")
1
196 mm
(7.7")
152 mm
(6")
44.5 mm
(1.75")
45º Horizontal Elbow
(FGS-MH4E-G)
152 mm
(6")
44.5 mm
(1.75")
45º Up Elbow
(FGS-MU4E-G)
318108AE 12/13 www.te.com/enterprise-asia
61
2x6 System
Part Drawings
57 mm
(2.25")
221 mm
(8.7")
196 mm
(7.7")
196 mm
(7.7")
196 mm
(7.7")
145 mm
(5.7")
81 mm
(3.2")
188 mm
(7.4")
165 mm
(6.5")
51 mm
(2")
262 mm
(10.3")
191 mm
(7.5")
76 mm
(3")
86 mm
(3.4")
152 mm
(6")
53 mm
(2.1")
41 mm
(1.6")
56 mm
(2.2")
114 mm
(4.5")
2x6 to 4x4 Adapter
(FGS-MDSA-GA)
71 mm
(2.8")
2x6 to 4x6 Adapter
(FGS-MDSA-GB)
196 mm
(7.7")
133 mm
(5.2"
51 mm
(2")
Trumpet Flare
(FGS-MTRM-G)
140 mm
(5.5")
5. FiberGuide System
152 mm
(6")
268 mm
(10.6")
99 mm
(3.9")
131 mm
(5.16")
47 mm
(1.9")
Low-Profile
Express Exit™ Downspout
45º Down Elbow
(FGS-MD4E-G)
(FGS-MEXP-LP-G)
224 mm
(8.8")
33 mm
(1.31")
70 mm
(2.75")
3 mm
(.125")
152 mm
(6")
71 mm
(2.8")
45 mm
(1.75")
57 mm
(2.25")
3 mm
(.125")
160 mm
(6.3")
152 mm
(6")
51 mm
(2")
119 mm
(4.7")
127 mm
(5")
Straight Section
(FGS-MSHS-G)
Junction
(FGS-JUNC-G)
188 mm
(7.4")
210 mm
(8.3")
16 mm
(6.25")
24 mm
(1")
Side
End
93 mm
(3.7")
Side
End
Straight Section
(Not Included)
Straight Section
(Not Included)
Hinged Covers for Straight Section
(FGS-MSNC-B/G)
62
83 mm
(3.25")
Snap-on Covers for Horizontal Straight Section
(FGS-MSSC-B/G)
www.te.com/enterprise-asia 12/13 318108AE
4x6 System
Horizontal T
Horizontal Cross
90° Horizontal Elbow
(FGS-MHRT-B)
(FGS-MHXP-B)
(FGS-MH9E-B)
90° Up Elbow
90° Down Elbow
45° Horizontal Elbow
Cover Included
(FGS-MU9E-B)
(FGS-MD9E-B)
(FGS-MH4E-B)
45° Up Elbow
45° Down Elbow
4x4 to 4x6 Straight Adapter
Cover Included
(FGS-MD4E-B)
(FGS-MDSA-AB)
5. FiberGuide System
Fittings – 4" H x 6" W
(FGS-MU4E-B)
Expandable
Straight Section
(FGS-MVAR-B)
6" Cut-in T
Cut-in T Fixture
(FGS-MHIS-B)
(FGS-MHIS-JIG-A/B/F shown on
a straight section)
4x12 to Single 4x6 Adapter
End Cap
Snap-on Plastic Cover
(FGS-MDSA-FB)
(FGS-HMEC-B)
(FGS-SH4E-B shown attached
to 45° horizontal elbow
with junctions)
(Cover: FGS-SDSA-FB)
318108AE 12/13 www.te.com/enterprise-asia
63
4x6 System
Fittings – 4" H x 6" W
ORDERING INFORMATION
Part Number
Description
Number
of
Junctions
Yellow System
Yellow System
Snap-on Cover
Black System
Black System
Snap-on Cover
Fixed
Metal Cover
4x6 fittings
5. FiberGuide System
Horizontal T
3
FGS-MHRT-B
FGS-SHRT-B
FGSB-MHRT-B
FGSB-SHRT-B
FGS-CHRT-B
Horizontal cross
4
FGS-MHXP-B
FGS-SHXP-B
FGSB-MHXP-B
FGSB-SHXP-B
FGS-CHXP-B
90° horizontal
elbow
2
FGS-MH9E-B
FGS-SH9E-B
FGSB-MH9E-B
FGSB-SH9E-B
FGS-CH9E-B
90° up elbow
metal cover
included
2
FGS-MU9E-B
–
FGSB-MU9E-B
–
FGS-CU9E-B
90° down elbow
2
FGS-MD9E-B
FGS-SD9E-B
FGSB-MD9E-B
FGSB-SD9E-B
FGS-CD9E-B
45° horizontal
elbow
2
FGS-MH4E-B
FGS-SH4E-B
FGSB-MH4E-B
FGSB-SH4E-B
FGS-CH4E-B
45° up elbow
metal cover
included
2
FGS-MU4E-B
FGS-SU4E-B
FGSB-MU4E-B
FGSB-SU4E-B
FGS-CU4E-B
45° down elbow
2
FGS-MD4E-B
FGS-SD4E-B
FGSB-MD4E-B
FGSB-SD4E-B
FGS-CD4E-B
(1) 4x4,
(1) 4x6
FGS-MDSA-AB
FGS-SDSA-AB
FGSB-MDSA-AB
FGSB-SDSA-AB
FGS-CDSA-AB
4x12 to single
4x6 adapter
–
FGS-MDSA-FB
FGS-SDSA-FB
FGSB-MDSA-FB
FGSB-SDSA-FB
–
4x6 expandable
straight section
2
FGS-MVAR-B
–
FGSB-MVAR-B
–
–
4" Cut-in T;
assembly
hardware
included
–
FGS-MHIS-A
–
FGSB-MHIS-A
–
–
6" Cut-in T;
assembly
hardware
included
–
FGS-MHIS-B
–
FGSB-MHIS-B
–
–
12" Cut-in T;
assembly
hardware
included
–
FGS-MHIS-F
–
FGSB-MHIS-F
–
–
Cut-in T fixture
–
FGS-MHIS-JIG-A/B/F
–
FGS-MHIS-JIG-A/B/F
–
–
–
FGS-HMEC-B
–
FGS-HMEC-B
–
–
4x6 conversions
4x4 to 4x6
straight adapter
4x6 end cap
64
www.te.com/enterprise-asia 12/13 318108AE
4x6 System
Downspout
Cover for 4x6 Downspout
Extended Downspout
(FGS-MDSP-B)
(FGS-MCDS-AB)
(FGS-MDSP-EX-B shown with
and without cover)
Insertable Downspout
Dual Downspout
Dual Downspout with Divider
(FGS-MDSP-B/I)
(FGS-MDSP-2B)
(FGS-MDSP-2B-IMP)
Trumpet Flare Kit for 4x6
Dual Downspout
Trumpet Flare Kit for Dual
Downspout with Divider
(FGS-MTRM-2B-IMP)
Single 2"Flex Tube
Attachment
Trumpet Flare Kit
(FGS-MTRM-A shown attached
to downspout)
4x4/4x6 Downspout Insert
Downspout Exit Junction Kit
(FGS-HDSI-AB)
(FGS-MJWR-A)
4" Square to 2" Round
Adapter with Flex Tube
Dual 2" Flex Tube Attachment
(FGS-KT03-A)
2" Quad Flex
Flex Tube Attachment
(FGS-KT03-A4)
(FGS-MTRM-2B)
(FGS-ASRI requires
FGS-MJWR-A junction kit)
5. FiberGuide System
Downspouts and Attachments – 4" H x 6" W
(FGS-KT03-A1)
318108AE 12/13 www.te.com/enterprise-asia
65
4x6 System
Downspouts and Attachments – 4" H x 6" W
4x6 downspouts and attachments feed fiber from overhead straight
sections into fiber optic equipment below. All 4x6 downspouts feature
4-inch exits and attach to the 4-inch x 4-inch attachments listed below.
ORDERING INFORMATION
Part Number
Number of
Junctions
Description
Yellow System
Black System
FGS-MDSP-B
FGSB-MDSP-B
4x6 downspouts
Downspout Note: If a trumpet flare is required
use a 4x4 flare (FGS-MTRM-A)
2*
Cover for 4x6 downspout and dual downspout
–
FGS-MCDS-AB**
FGSB-MCDS-AB**
Extended downspout
2
FGS-MDSP-EX-B
FGSB-MDSP-EX-B
5. FiberGuide System
Cover for 4x6 extended downspout
–
FGS-MCDS-EX-AB
FGSB-MCDS-EX-AB
Insertable downspout
–
FGS-MDSP-B/I
FGSB-MDSP-B/I
Dual drop downspout
2*
FGS-MDSP-2B
FGSB-MDSP-2B
Trumpet flare for dual drop downspout
(kit of 2 FGS-MTRM-A)
–
FGS-MTRM-2B
FGSB-MTRM-2B
Dual drop downspout with divider
2
FGS-MDSP-2B-IMP
FGSB-MDSP-2B-IMP
FGS-MTRM-2B-IMP
FGSB-MTRM-2B-IMP
Junction for downspout exit
FGS-MJWR-A
FGSB-MJWR-A
4x4/4x6 downspout insert; converts bottom of downspout to
2x2 without using 2" to 4" adapter, saving vertical space
FGS-HDSI-AB
FGS-HDSI-AB
Trumpet flare; used on both 4x4 and 4x6 downspouts —
no 4" junction kit required
FGS-MTRM-A
FGSB-MTRM-A
Trumpet flare for dual drop downspout with divider (kit of 2)
4x6 attachments
4x4 square to 2" round adapter with flex tube;
one 4x4 junction kit (FGS-MJWR-A) required to attach to a downspout drop
5' length
1
FGS-ASRI-5F
FGSB-ASRI-5F
10' length
1
FGS-ASRI-10F
FGSB-ASRI-10F
15' length
1
FGS-ASRI-15F
FGSB-ASRI-15F
4x4 dual 2" flex tube attachment; no 4x4 junction kit required
(2) 5' length
–
FGS-KT03-A
FGSB-KT03-A
(2) 10' length
–
FGS-KT03-A10F
FGSB-KT03-A10F
(2) 15' length
–
FGS-KT03-A15F
FGSB-KT03-A15F
–
FGS-KT03-A1
FGSB-KT03-A1
4x4 single 2" flex tube attachment; no 4x4 junction kit required
5' length
10' length
–
FGS-KT03-A1-10F
FGSB-KT03-A1-10F
15' length
–
FGS-KT03-A1-15F
FGSB-KT03-A1-15F
(4) 5' length
–
FGS-KT03-A4-5F
FGSB-KT03-A4-5F
(4) 10' length
–
FGS-KT03-A4-10F
FGSB-KT03-A4-10F
(4) 15' length
–
FGS-KT03-A4-15F
FGSB-KT03-A4-15F
–
FGS-KT07-A4-5F
FGSB-KT07-A4-5F
4x4 quad 2" flex tube attachment; no 4x4 junction kit required
4x4 quad 7/8" flex tube attachment; no 4x4 junction kit required
(4) 5' length
(4) 10' length
–
FGS-KT07-A4-10F
FGSB-KT07-A4-10F
(4) 15' length
–
FGS-KT07-A4-15F
FGSB-KT07-A4-15F
*A 4x4 junction is needed to drop to a fitting or a straight section.
This drop junction must be a junction type FGS-MJWR-A or FGSB-MJWR-A.
**Dual downspout requires two covers.
66
www.te.com/enterprise-asia 12/13 318108AE
4x6 System
Straight Section and Snap-Fit™ Junction – 4" H x 6" W
Straight Section
Horizontal
Straight Section
Expandable Straight
Section
(FGS-x-B)
(FGS-MVAR-B)
Hinged Cover Kit
for Horizontal Straight
Section
6" Snap-on Cover
for Horizontal
Straight Section
(FGS-MSNC-B/G)
(FGS-MSSC-B/G)
ORDERING INFORMATION
Part Number
Description
Yellow System
Black System
4x6 straight sections
Horizontal straight section; 6' long, cover sold seperately
FGS-MSHS-B
FGSB-MSHS-B
Expandable straight section
FGS-MVAR-B
FGSB-MVAR-B
FGS-MSHS-STOR-B
FGSB-MSHS-STOR-B
Hinged cover kit for horizontal straight section;
includes three mounting hinges and three clips
FGS-MSNC-B/G
FGSB-MSNC-B/G
6" snap-on cover kit for horizontal straight section;
includes six capture clips with mounting clasps
FGS-MSSC-B/G
FGSB-MSSC-B/G
FGS-DHCP
FGS-DHCP
FGS-DHHC
(Yellow Hinge)
FGSB-DHHC
(Black Hinge)
Slack storage straight section
4x6 accessories
Kit - 10 black capture clips
Kit - 10 black capture clips and 10 hinges
Snap-Fit™ Junction
The Snap-Fit™ junction assembly is available for the 6-inch FiberGuide
system. The new junction is a completely tool-less junction. No additional tools
are required for installation or removal. The Snap-Fit Junction exhibits superior
holding force and accommodates support brackets. A warning label indicating
caution around fiber optic cable is included with each junction kit.
Snap-Fit Junction
(FGS-MFAW-B)
ORDERING INFORMATION
Part Number
Description
4x6 Snap-fit junction
318108AE 12/13 www.te.com/enterprise-asia
Yellow System
Black System
FGS-MFAW-B
FGSB-MFAW-B
67
5. FiberGuide System
The unique four-channel design of the 4x6 FiberGuide straight section allows
the standard system to be attached to the support structure without the need
to cut or drill any holes within the trough. This ensures that the patch cords will
not come in contact with any screw heads or bolts, an important consideration
in 4x6 systems where higher cable counts apply increased pressure on patch
cords at the bottom of the trough.
4x6 System
Part Drawings
381 mm
(15")
381 mm (15")
288 mm
(11.3")
Top
381 mm
(15")
288 mm
(11.3")
288 mm
(11.3")
Top
152 mm (6")
152 mm
(6")
112 mm
(4.4"
Horizontal T
(FGS-MHRT-B)
Top
112 mm
(4.4"
)
5. FiberGuide System
152 mm
(6")
End
Horizontal Cross
(FGS-MHXP-B)
112 mm
(4.4"
90° Horizontal Elbow
(FGS-MH9E-B)
259 mm
(10.2"
)
114 m m
(4.5")
245 mm
(9.7"
)
152 mm
(6")
Front
Front
Top
108 m m
(4.25")
86 m m
(3.4")
196 m m
(7.7")
183 m m
(7.2")
13 m m
(.5")
108 m m
(4.25")
112 mm
(4.4"
)
218 m m
(8.6")
End
45° Horizontal Elbow
(FGS-MH4E-B)
90º Up Elbow
(FGS-MU9E-B)
251 mm (10")
Top
152 mm
(6")
245 mm
(9.7"
)
259 mm
(10.2"
)
213 mm
(8.4")
R 5.1 mm
(2")
112 mm
(4.4"
)
203 mm
(8")
124 mm (4.9")
End
90° Down Elbow
(FGS-MD9E-B)
152 mm
(6"
)
Top
Side
210 mm
(8.3")
45° Up Elbow
(FGS-MU4E-B)
45°
203mm (8")
End
195 mm
(7.7"
)
Side
123 mm
(4.9"
)
112 mm
(4.4"
)
163 mm
(6.4"
)
45° Down Elbow
(FGS-MD4E-B)
68
www.te.com/enterprise-asia 12/13 318108AE
Junction De
(Not Includ
166 mm
(6.6")
4x6 System
Part Drawings
396 mm
(15.6")
305 mm
(12")
356 mm
(14")
Retracted Straight Section
152 mm
(6")
Trumpet Flare
(FGS-MTRM-B)
329 mm
(13")
112 mm
(4.4")
160 mm
(6.3"
195 mm
(7.7")
144 mm
(5.7")
44 mm
(1.75")
330 mm
(13")
211 mm
(8.3")
102 mm
(4")
144 mm
(5.7")
Downspout
(FGS-MDSP-B)
Extended Downspout
(FGS-MDSP-EX-B)
195 mm
(7.7"
)
188 mm
(7.4")
152 mm
(6")
102 mm
(4")
16 mm
(.625")
End
133 mm
(5.25")
116 mm
(4.6"
)
End
Side
183 mm
(72")
Straight Section
(Not Included)
Horizontal Straight Section
(FGS-MSHS-B)
6" Snap-On Cover for Straight Section
(FGS-MSSC-B/G)
108 mm
(4.25"
)
210 mm
(8.3")
24 mm
(1")
138 mm
(5.4")
5. FiberGuide System
Front
Side
End
159 mm
(6.25")
6" Cut-in T
(FGS-MHIS-B)
329 mm (13")
102 mm
(4")
76 mm
(3")
356 mm
(14")
Expandable Straight Section
(FGS-MVAR-B)
Top
Top
263 mm
(10.4")
51 mm
(2")
381 mm
(15")
559 mm
(22")
Expanded Straight Section
CLOSE
R 51 mm
(2")
OPEN
159 mm
(6.25")
End
Side
Straight Section
(Not Included)
Hinged Cover for Straight Section
(FGS-MSNC-B/G)
224 mm
(8.8"
)
230 mm
152
mm
(9")
(6.0"
)
140 mm
(5.51"
143
mm)
(5.6
")
305 mm
(12")
89 mm (3.5"
)
diameter
32 mm
(1.25)
152 mm
(6")
Snap-Fit Junction Assembly
(FGS-MFAW-B)
Slack Storage Straight Section
(FGS-MSHS-STOR-B)
318108AE 12/13 www.te.com/enterprise-asia
69
4x12 System
Fittings – 4" H x 12" W
Horizontal Cross
90° Horizontal Elbow
90° Down Elbow
(FGS-MHXP-F)
(FGS-MH9E-F)
(FGS-MD9E-F)
45° Horizontal Elbow
45° Up Elbow
45° Down Elbow
(FGS-MH4E-F)
(FGS-MU4E-F)
(FGS-MD4E-F)
Horizontal Cross
with Two 6" Exits
4x12 to Dual 4x6 Adapter
4x12 to Single 4x6 Adapter
(FGS-MDSA-F2B)
(FGS-MDSA-FB)
4x12 to 4x6 Adapter – Left
End Cap
(FGS-MDSA-FB-L)
(FGS-HMEC-F)
Expandable
Straight Section
Snap-on Cover Installation
5. FiberGuide System
Horizontal T
(FGS-MHRT-F)
(FGS-MHXP-B/F)
(FGS-MVAR-F)
Cut-in T Fixture
Snap-on Cover
(FGS-MHIS-JIG-A/B/F shown
on a straight section)
(FGS-SH4E-F
shown separate)
70
www.te.com/enterprise-asia 12/13 318108AE
Horizontal T
with Single 6" Exit
(FGS-MHRT-F/B)
4x12 to 4x6
Adapter – Right
(FGS-MDSA-FB-R)
12" Cut-in T
(FGS-MHIS-F)
Snap-on Cover
(FGS-SH4E-F shown installed)
4x12 System
Fittings – 4" H x 12" W
ORDERING INFORMATION
Part Number
Description
Number of
Junctions
Yellow System
Yellow System
Snap-on Cover
Black System
Black System
Snap-on Cover
4x12 fittings
Horizontal T
3
FGS-MHRT-F
FGS-SHRT-F
FGSB-MHRT-F
FGSB-SHRT-F
Horizontal cross
4
FGS-MHXP-F
FGS-SHXP-F
FGSB-MHXP-F
FGSB-SHXP-F
90° horizontal elbow
2
FGS-MH9E-F
FGS-SH9E-F
FGSB-MH9E-F
FGSB-SH9E-F
90° down elbow
2
FGS-MD9E-F
FGS-SD9E-F
FGSB-MD9E-F
FGSB-SD9E-F
45° horizontal elbow
2
FGS-MH4E-F
FGS-SH4E-F
FGSB-MH4E-F
FGSB-SH4E-F
45° up elbow, metal
cover included
2
FGS-MU4E-F
FGS-SU4E-F
FGSB-MU4E-F
FGSB-SU4E-F
45° down elbow
2
FGS-MD4E-F
FGS-SD4E-F
FGSB-MD4E-F
FGSB-SD4E-F
Horizontal T
with single 6" exit
(2) 4x12,
(1) 4x6
FGS-MHRT-F/B
FGS-SHRT-F/B
FGSB-MHRT-F/B
FGSB-SHRT-F/B
Horizontal cross
with two 6" exits
(2) 4x12,
(2) 4x6
FGS-MHXP-B/F
FGS-SHXP-B/F
FGSB-MHXP-B/F
FGSB-SHXP-B/F
4x12 to dual 4x6 adapter
(1) 4x12,
(2) 4x6
FGS-MDSA-F2B
FGS-SDSA-F2B
FGSB-MDSA-F2B
FGSB-SDSA-F2B
4x12 to single 4x6 adapter
(1) 4x12,
(1) 4x6
FGS-MDSA-FB
FGS-SDSA-FB
FGSB-MDSA-FB
FGSB-SDSA-FB
4x12 to 4x6 right adapter;
includes fastening hardware
FGS-MDSA-FB-R
FGS-MDSA-FB-R
Fixed metal cover
for right adapter
FGS-VDSA-FB-R
FGS-VDSA-FB-R
4x12 to 4x6 left adapter;
includes fastening hardware
FGS-MDSA-FB-L
FGS-MDSA-FB-L
Fixed metal cover
for left adapter
FGS-VDSA-FB-L
FGS-VDSA-FB-L
Expandable straight section
2
FGS-MVAR-F
–
FGSB-MVAR-F
–
4" Cut-in T;
assembly hardware included
–
FGS-MHIS-A
–
FGSB-MHIS-A
–
6" Cut-in T;
assembly hardware included
–
FGS-MHIS-B
–
FGSB-MHIS-B
–
12" Cut-in T;
assembly hardware included
–
FGS-MHIS-F
–
FGSB-MHIS-F
–
Cut-in T fixture
–
FGS-MHIS-JIG-A/B/F
–
FGS-MHIS-JIG-A/B/F
–
4x12 end cap
FGS-HMEC-F
FGS-HMEC-F
4x12 variable support locator kits for; Each kit contains all necessary mounting hardware. Fitting sold separately.
FGS-MDSP-F (downspout)
FGS-MDSP-F-VS
FGS-MHRT-F (horizontal T)
FGS-MHRT-F-VS
FGS-MHRT-F-VS
FGS-MHXP-F (horizontal cross)
FGS-MHXP-F-VS
FGS-MHXP-F-VS
FGS-MH9E-F (90° horizontal elbow)
FGS-MDSP-F-VS
FGS-MH9E-F-VS
FGS-MH9E-F-VS
FGS-MHRT-F/B (horizontal T – 6"/12")
FGS-MHRT-F/B-VS
FGS-MHRT-F/B-VS
FGS-MHXP-B/F (horizontal cross– 6"/12")
FGS-MHXP-B/F-VS
FGS-MHXP-B/F-VS
318108AE 12/13 www.te.com/enterprise-asia
71
5. FiberGuide System
4x12 conversions
4x12 System
Downspouts and Attachments – 4" H x 12" W
Downspout
Cover for 4x12 Downspout
Trumpet Flare
(FGS-MDSP-F)
(FGS-SDSP-F)
(FGS-MTRM-F)
Island T
Island T with Recessed Dividing Spool
(FGS-MDRT-F)
(FGS-ISLAND-F)
(FGS-ISLAND3-F shown with 12"
Junction, 90° Down Elbow and
Trumpet Flare)
4x6 Dual 2" Flex Tube
Attachment
(FGS-KT03-B)
4x6 Trumpet Flare Kit
(FGS-MTRM-B shown
alone and attached to 4x12
Downspout)
4x12 to 4x4 Downspout
Converter
(FGS-HDSI-F/D)
5. FiberGuide System
Downspout with Rear T
The FGS-HSDI-F/D attached to both the 4x12 downspout and the
4x4 slotted duct without the use of hardware
72
www.te.com/enterprise-asia 12/13 318108AE
4x12 System
Downspouts and Attachments – 4" H x 12" W
An array of 4x12 downspouts and attachments are available to feed fiber
from overhead straight sections into fiber optic equipment below. The 4x12
downspout features a 4x6 exit and accepts the 4x6 exit attachments
listed below.
ORDERING INFORMATION
Part Number
Number of
Junctions
Description
Yellow System
Black System
FGS-MDSP-F
FGSB-MDSP-F
Downspout
2*
Cover for 4x12 downspout
–
FGS-SDSP-F
FGSB-SDSP-F
Insertable downspout
–
FGS-MDSP-F/I
FGSB-MDSP-F/I
Trumpet flare
–
FGS-MTRM-F
FGSB-MTRM-F
Downspout with rear T
3*
FGS-MDRT-F
FGSB-MDRT-F
Island T with spool and factory installed trumpet flare
2
FGS-ISLAND-F
FGSB-ISLAND-F
Island T with trumpet and dividing spool; Variable Support Locator Kit included
2
FGS-ISLAND-F-513
FGSB-ISLAND-F-513
Island T with recessed dividing spool
3
FGS-ISLAND3-F
FGSB-ISLAND3-F
4x12 attachments
4x6 dual 2" flex tube attachment
5' length
–
FGS-KT03-B
FGSB-KT03-B
10' length
–
FGS-KT03-B-10F
FGSB-KT03-B-10F
15' length
–
FGS-KT03-B-15F
FGSB-KT03-B-15F
FGS-MTRM-B
FGSB-MTRM-B
4x6 trumpet flare kit;
used on 4x12 downspouts
4x12 to 4x4 downspout converter;
converts downspout opening to accept
4x4 slotted duct
–
FGS-HDSI-F/D
FGS-HDSI-F/D
4x12 to 2x2 downspout converter
–
FGS-HDSI-F/C
FGS-HDSI-F/C
*An additional junction is needed if drop is to fitting or straight section.
This 4x6 junction must be a junction type FGS-MFAW-B, FGSB-MFAW-B.
318108AE 12/13 www.te.com/enterprise-asia
73
5. FiberGuide System
4x12 downspouts
4x12 System
Straight Section – 4" H x 12" W
The unique nine-channel design of the 4x12 FiberGuide straight section
provides unmatched strength and allows the attachment of support structure
without the need to cut or drill holes within the raceway. This ensures that
the patch cords will not come in contact with any screw heads or bolts,
an important consideration in 4x4, 4x6, and 4x12 systems where higher
cable counts apply increased pressure on the patch cords at the bottom
of the raceway.
The 4x12 system covers feature a snap-on design. This allows the cover to be
used in environments with limited headroom. Two 3-foot cover sections come
with each order, making it easy for one person to remove the covers. Each
cover kit includes a tether kit. The straight section covers are designed to be
placed over the 4x12 downspouts, speeding installation time by reducing the
number of measurements and cuts that need to be made.
5. FiberGuide System
Horizontal Straight Section
(FGS-MSHS-F)
Horizontal Straight Section Cover
(FGS-MSSC-F includes two 3' Lengths
and Tethering Hardware)
12" Hinged Cover for Horizontal
Straight Section
(FGS-MSNC-F)
Straight Section Cover in
Tethered Position
Expandable Straight Section
(FGS-MVAR-F)
Straight Section Cover Attached to
Straight Section
ORDERING INFORMATION
Part Number
Description
Yellow System
Black System
FGS-MSHS-F
FGSB-MSHS-F
4x12 straight section
Horizontal straight section; 6' long, cover sold seperately
Expandable straight section
FGS-MVAR-F
FGSB-MVAR-F
FGS-MSHS-STOR-F
FGSB-MSHS-STOR-F
Hinged cover kit for horizontal straight section;
includes five mounting hinges and three clips
FGS-MSNC-F
FGSB-MSNC-F
Snap-on cover kit for horizontal straight section;
includes 3' covers, optional tethering kit
FGS-MSSC-F
FGSB-MSSC-F
Slack storage straight section
4x12 accessories
Kit - 10 black capture clips
FGS-DHCP
FGS-DHCP
Kit - 10 black capture clips and 10 hinges
FGS-DHHC
FGSB-DHHC
74
www.te.com/enterprise-asia 12/13 318108AE
4x12 System
Snap-Fit™ Junction – 4" H x 12" W
The new Snap-Fit™ junction is available for the 12-inch FiberGuide
system. The Snap-Fit junction is a completely tool-less junction. No
additional tools are required for installation or removal. The SnapFit junction exhibits superior holding force and accommodates
support brackets.
4x12 Snap-Fit Junction
(FGS-MFAW-F)
ORDERING INFORMATION
Part Number
Description
Yellow System
Black System
FGS-MFAW-F
FGSB-MFAW-F
5. FiberGuide System
4x12 Snap-Fit™ junction
318108AE 12/13 www.te.com/enterprise-asia
75
4x12 System
Part Drawings
305 mm
(12")
533 mm
(21")
347 mm
(13.6")
440 mm
(17.3")
Top
112 mm
(4.4")
533 mm
(21")
347 mm
(13.7")
Horizontal Cross
(FGS-MHXP-F)
112 mm
(4.4")
(12")
Top
112 mm
(4.4")
347 mm
(13.7")
Horizontal T
(FGS-MHRT-F)
305 mm
533 mm
(21")
305 mm
(12")
305 mm
(12")
347 mm
(13.7")
112 mm
(4.4")
440 mm
(17.3")
208 mm
(8.2"
347 mm
(13.7")
440 mm
(17.3")
208 mm
(8.2")
5. FiberGuide System
Top
Side
90° Down Elbow
(FGS-MD9E-F)
90° Horizontal Elbow
(FGS-MH9E-F)
305 mm
(12")
112 mm
(4.4")
305 mm
(12")
367 mm
(14.4")
340 mm
(13.4")
112 mm
(4.42")
53.6 mm
(2.11")
135.0˚
166 mm
(6.55"
347 mm
(13.7")
398 mm
(15.7")
Top
347 mm
(13.7")
210 mm
(8.27")
45° Up Elbow
(FGS-MU4E-F)
163 mm
(6.4"
305 mm
(12")
Side
45° Down Elbow
(FGS-MD4E-F)
76
381 mm
(15")
305 mm
(12")
112 mm
(4.4")
347 mm
(13.7")
12" 45˚ Up FiberG
Side
45° Horizontal Elbow
(FGS-MH4E-F)
347 mm
(13.7")
152 mm
(6")
Top
112 mm 440 mm
(4.42") (17.3")
195 mm
(7.7")
Horizontal T with (one) 6" Exit
(FGS-MHRT-F/B)
www.te.com/enterprise-asia 12/13 318108AE
25 mm
(1")
4x12 System
Part Drawings
380 mm
(15")
152 mm
(6")
305 mm
(12")
305 mm
(12")
112 mm
(4.4")
Top
Top
347 mm
(13.7"
)
112 mm
(4.4")
465 mm
(18.3")
347 mm
(13.7")
279 mm
(11")
195 mm
(7.7")
Horizontal Cross with (two) 6" Exits
(FGS-MHXP-F/B)
4x12 to 4x6 Dual Adapter
(FGS-MDSA-F2B)
254 mm
(10")
305 mm
(12")
112 mm
(4.4")
Top
347 mm
(13.7")
343 mm
(13.5")
113 mm
(4.4"
195 mm
(7.7")
152 mm
(6")
152 mm
(6")
4x12 to 4x6 Adapter
(FGS-MDSA-FB)
5. FiberGuide System
533 mm
(21")
195 mm
(7.7")
End Cap
(FGS-HMEC-F)
457 mm
(18")
548 mm
(21.6")
159 mm
(6.25")
356 mm
(14")
Retracted Straight Section
533 mm
(21")
305 mm
(12")
559 mm
(22")
Expanded Straight Section
Expandable Straight Section
(FGS-MVAR-F)
508 mm
(20")
12" Cut-in T
(FGS-MHIS-F)
381 mm
(15")
347 mm
(13.7")
63.5 mm
(2.5")
305 mm
(12")
112 mm
(4.42"
Top
31.32 mm
(12.3")
88.9 mm
(3.5")
63.5 mm
(2.5")
152 mm
(6")
Downspout
(FGS-MDSP-F)
211 mm
(8.3")
50.8 mm
(2")
414 mm
(16.3")
Trumpet Flare
(FGS-MTRM-F)
318108AE 12/13 www.te.com/enterprise-asia
77
4x12 System
Part Drawings
318 mm
(12.5")
267 mm
(10.5")
439 mm
(17.3")
173 mm
(6.8")
267 mm
(10.5")
203 mm
(8")
102 mm
(4")
Island T with Recessed Dividing Spool
(FGS-ISLAND3-F)
89 mm
(3.5")
4 mm
(.2")
160 mm
(6.3")
Island T
(FGS-ISLAND-F)
279 mm
(11")
94 mm
(3.7")
102 mm
(4")
5. FiberGuide System
533 mm
(21")
38 mm
(1.5")
145 mm
(5.7")
127 mm
(5")
73.7 mm
(2.9")
272 mm
(10.7")
254 mm
(10")
127 mm
(5")
Straight Section
(FGS-MSHS-F)
439 mm
(17.3"
366 mm
(14.4")
422 mm
(16.6")
279 mm
(11")
25 mm
(1")
Side
490 mm
(19.3"
End
93.2 mm
(3.7")
Straight Section
(Not Included)
Hinged Cover for Horizontal Straight Section
(FGS-MSNC-F)
Downspout with Rear T
(FGS-MDRT-F)
108 mm
(4.25”)
382 mm
(15”)
133 mm
(5.2”)
305 mm
(12")
89 mm (3.5"
)
108 mm
diameter
)
(4.25"
205 mm
(12”)
Snap-Fit Junction
(FGS-MFAW-F)
78
Slack Storage Straight Section
(FGS-MSHS-STOR-F)
www.te.com/enterprise-asia 12/13 318108AE
4x24 System
Fittings – 4" H x 24" W
45° Horizontal Elbow
Horizontal Cross with Dual
12" Exits
(FGS-MHXP-F/H)
Horizontal Cross
(FGS-MHXP-H)
(FGS-MH4E-H)
Horizontal T
with Single 12" Exit
45° Down Elbow
4x24 to 4x12 Adapter
45° Up Elbow
(FGS-MD4E-H)
(FGS-MDSA-HF)
(FGS-MU4E-H)
(FGS-MHRT-H/F)
12" Cut-in T
(FGS-MHIS-F/H)
5. FiberGuide System
End Cap
(FGS-HMEC-H)
ORDERING INFORMATION
Part Number
Description
Yellow System
Black System
4x24 fittings
45° horizontal elbow
Horizontal T with single 12" exit
FGS-MH4E-H
FGSB-MH4E-H
FGS-MHRT-H/F
FGSB-MHRT-H/F
Horizontal T with three 24" exits
FGS-MHRT-H
FGSB-MHRT-H
Horizontal cross
FGS-MHXP-H
FGSB-MHXP-H
FGS-MHXP-F/H
FGSB-MHXP-F/H
Horizontal cross with dual 12" exits
45° up elbow
FGS-MU4E-H
FGSB-MU4E-H
45° down elbow
FGS-MD4E-H
FGSB-MD4E-H
4x24 conversions
12" cut-in T for 4x24*
FGS-MHIS-F/H
FGSB-MHIS-F/H
6" cut-in T for 4x24*
FGS-MHIS-B/H
FGSB-MHIS-B/H
4" cut-in T for 4x24*
FGS-MHIS-A/H
FGSB-MHIS-A/H
4x24 to 4x12 adapter
FGS-MDSA-HF
FGSB-MDSA-HF
FGS-HMEC-H
FGS-HMEC-H
4x24 end cap
*Designed exclusively for the 4x24" system.
318108AE 12/13 www.te.com/enterprise-asia
79
4x24 System
Downspouts – 4" H x 24" W
4x24 downspouts and attachments feed fiber from overhead straight sections into
fiber optic equipment below.
Island T with Single 12" Exit
Trumpet Flare
(FGS-ISLAND-H/F)
(FGS-MTRM-H)
ORDERING INFORMATION
Part Number
Description
Island T with single 12" exit
5. FiberGuide System
Trumpet flare
80
www.te.com/enterprise-asia 12/13 318108AE
Yellow System
Black System
FGS-ISLAND-H/F
FGSB-ISLAND-H/F
FGS-MTRM-H
FGS-MTRM-H
4x24 System
Straight Section, Snap-Fit™ Junctions and covers – 4" H x 24" W
Straight Section
The unique double wall channel design of the 4x24 straight section provides
exceptional strength and durability for high fiber count applications and allows
the standard system to be attached to the support structure without the need
to cut or drill any holes within the trough. The six channel design ensures
that the patch cords will not come in contact with any screw heads or bolts,
an important consideration in 4x24 systems where higher cable counts apply
increased pressure on patch cords at the bottom of the trough.
Straight Section
(FGS-MSHS-H)
ORDERING INFORMATION
Part Number
Description
4x24 straight section; horizontal straight section, 6' long
Yellow System
Black System
FGS-MSHS-H
FGSB-MSHS-H
The Snap-Fit™ Junction assembly is available for the 24-inch FiberGuide
System. The Snap-Fit junction is a completely tool-less junction. No additional
tools are required for installation or removal. The junction exhibits superior
holding force and accommodates support brackets. A warning label is included
with each junction kit.
Snap-Fit Junction
ORDERING INFORMATION
(FGS-MFAW-H)
Part Number
Description
4x24 Snap-Fit™ junction
Yellow System
Black System
FGS-MFAW-H
FGSB-MFAW-H
Cover Kits
ORDERING INFORMATION
Description
Part Number
Cover for 4"x24"x6' straight section - FGS-MSHS-H
FGS-FSFC-H
Cover for 4"x24"horizontal tee with single 12" Exit - FGS-MHRT-H/F
FGS-FHRT-H/F
Cover for 4"x24"horizontal cross with dual 12" Exits - FGS-MHXP-F/H
FGS-FHXP-F/H
Cover for 4"x24"horizontal cross - FGS-MHXP-H
FGS-FHXP-H
Cover for 4"x24" 45° horizontal elbow - FGS-MH4E-H
FGS-FH4E-H
Cover for 4"x24"horizontal tee - FGS-MHRT-H
FGS-FHRT-H
Cover for 4"x24" 4° down elbow - FGS-MD4E-H
FGS-FD4E-H
Cover for 4"x24" to 4"x12" reducer - FGS-MDSA-HF
318108AE 12/13 www.te.com/enterprise-asia
FGS-FDSA-HF
81
5. FiberGuide System
Snap-Fit Junction
4x24 System
Part Drawings
584 mm
(23")
108 mm
(4.25")
697 mm
(27.5")
102 mm
(4")
89 mm
(3.5")
94 mm
(3.7")
144 mm
(5.7")
576.6 mm
(22.7")
610 mm
(24")
Straight Section
(FGS-MSHS-H)
127 mm
(5")
Snap-Fit Junction
(FGS-MFAW-H)
4 x 24 Straight Section
FGS-MSHS-H
533.1 mm
(20.99")
4x24 Snap-Fit Junction
610 mm
FGS-MFAW-H
(24")
610 mm
(24")
581 mm
(22.9")
120 mm
(4.7")
305 mm
(12")
745 mm
(29.3")
652 mm
(25.7")
120 mm
(4.7")
652 mm
(25.7")
701 mm
(27.6")
347 mm
(13.7")
5. FiberGuide System
4x24 45° Horizontal
Elbow
45°
Horizontal Elbow
FGS-MH4E-H (FGS-MH4E-H)
Horizontal T with Single 12" Exit
(FGS-MH4E-H)
4x24 Horizontal T with Single 12" Exit
MGS-MHRT-H/F
533 mm
(21")
610 mm
(24")
652 mm
(25.7")
610 mm
(24")
120 mm
(4.7")
120 mm
(4.7")
305 mm
(12")
838 mm
(33")
652 mm
(25.7")
838 mm
(33")
347 mm
(13.7")
838 mm
(33")
Horizontal Cross
Horizontal Cross
(FGS-MHXP-H)
with Dual 12" Exits
4x24 Horizontal Cross with(FGS-MHXP-F/H)
Dual 12" Exits
FGS-MHXP-F/H
4x24 Horizontal Cross
FGS-MHXP-H
795 mm
(31.3")
470 mm
(18.5")
419 mm
(16.5")
203 mm
(8")
645 mm
(25.4")
160 mm
(6.3")
4 mm
(.2")
114 mm
(4.5")
End Cap
4x24 End Cap
(FGS-HMEC-H)
FGS-HMEC-H
82
Island T with Single 12" Exit
4x24 Island
T with Single 12" Exit
(FGS-ISLAND-H/F)
FGS-ISLAND-H/F
www.te.com/enterprise-asia 12/13 318108AE
4x24 to 4x12 Adapter
(FGS-MDSA-HF)
4x24
x 4x12 Adapter
FGS-MDSA-HF
4x24 System
Part Drawings
114 mm
(4.5")
160 mm
(6.3")
736 mm
(29")
134.3 mm
(5.3")
647 mm
(25.5")
610 mm
(24")
78 mm
(3.1")
610 mm
(24")
4x24 45° Up Elbow45° Up Elbow
FGS-MU4E-H (FGS-MU4E-H)
Trumpet
Flare Kit
4x24 Trumpet
(FGS-MTRM-H)
FGS-MTRM-H
345 mm
(13.6")
128 mm
(5")
330 mm
(13")
610 mm
(24")
178 mm
(7")
4" Cut-in T
Adapter Bracket
SIDE
45° Down Elbow
(FGS-MD4E-H)
305 mm
(12")
5. FiberGuide System
117 mm
(4.6")
102 mm
(4")
4" Cut-in T
designed exclusively for the 4x24 System
(FGS-MHIS-A/H)
4x24 45° Down Elbow
FGS-MD4E-H
4x4 Cut-in T for 4x24 FiberGuide
FGS-MHIS-A/H
396 mm
(15.6")
548 mm
(21.6")
128 mm
(5")
128 mm
(5")
533 mm
(21")
381 mm
(15")
152 mm
(6")
12" Cut-in T
Adapter Bracket
6" Cut-in T Adapter Bracket
356 mm
(14")
4x6 Cut-in T for 4x24 FiberGuide
6" Cut-in T
FGS-MHIS-B/H
305 mm
(12")
508 mm
(20")
designed exclusively for the 4x24 System
(FGS-MHIS-B/H)
4x12 Cut-in T for 4x24 FiberGuide
FGS-MHIS-F/H 12" Cut-in T
designed exclusively for the 4x24 System
(FGS-MHIS-F/H)
318108AE 12/13 www.te.com/enterprise-asia
83
Express Exit™ Family
For 4x4, 4x6 and 4x12 Systems
TE Connectivity's patented* Express Exit™ family accommodates various
raceway environments and applications. By simply securing an Express Exit
to the sidewall of any 4x4, 4x6, 4x12, or 4x24 FiberGuide straight section,
jumpers can be permanently or temporarily routed to fiber optic terminal (FOT)
equipment below. No cutting of the FiberGuide system is required. Positioning
a drop with a member of the Express Exit family greatly simplifies installation,
protects the integrity of fibers already present in the raceway, and increases
overall flexibility of the raceway system. All Express Exits guarantee 2-inch bend
radius protection.
Express
Exit Style
Express Exit Family
Height Above
Sidewall
Exit
Opening
3 mm Patch Cord
Capacity
2 mm Patch Cord
Capacity
Hinged
Rear Cover
Exit Fin Inserts
2-Inch
Express Exit
4"
2" x 2"1
150
350
No
No
Low-Profile
Express Exit
2"
2" x 2"1
150
350
No
No
4-Inch
Express Exit
4"
4" x 4"2
300
700
Yes
Yes
5. FiberGuide System
1
Accepts all standard 2x2" attachments.
Accepts all standard 4x4" attachments.
2
4-Inch Express Exit™
The 4-Inch Express Exit is designed to distribute and manage medium cable
counts to FOT or ODF equipment. It features a 4-inch by 4-inch exit opening
to accept all standard 4x4 downspout attachments and includes insertable exit
fins and removable rear cable guides for additional cable management.
4-Inch Express Exit
ORDERING INFORMATION
Part Number
Description
Yellow System
Black System
FGS-MEXP-E-A/B/F
FGSB-MEXP-E-A/B/F
FGS-MEXC-E-A/B/F
FGSB-MEXC-E-A/B/F
Express Exit rear hinged cover for 4x4 raceway
FGS-MEXC-E-A
FGSB-MEXC-E-A
Express Exit rear hinged cover for 4x6 raceway
FGS-MEXC-E-B
FGSB-MEXC-E-B
Express Exit rear hinged cover for 4x12 raceway
FGS-MEXC-E-F
FGSB-MEXC-E-F
4-inch Express Exit™
Express Exit; base, base cover, mounting hardware,
support bracket, and exit inserts included
4-inch accessories
Express Exit rear hinged cover kit;
one 4x4, 4x6, 4x12 rear hinged cover
*Other patents pending.
84
www.te.com/enterprise-asia 12/13 318108AE
Express Exit™ Family
For 4x4, 4x6 and 4x12 Systems
2-Inch Express Exit™
The 2-Inch Express Exit, TE's initial offering in the Express Exit product family,
accommodates up to 350, 2 mm patch cords. The patch cords are routed from
a 4x4, 4x6, 4x12 or 4x24 straight section to FOT equipment below the raceway.
2-Inch Express Exit
ORDERING INFORMATION
Part Number
Description
2-Inch Express Exit™; base, base cover, mounting hardware and support bracket
included
Yellow System
Black System
FGS-MEXP-A/B/F
FGSB-MEXP-A/B/F
Low-Profile Express Exit™
the FiberGuide straight section sidewall. It also includes removable rear cable
guides for additional cable management.
Low-Profile Express Exit
ORDERING INFORMATION
Part Number
Description
Low-Profile Express Exit™; base, base cover, mounting hardware and support bracket
included
Yellow System
Black System
FGS-MEXP-LP-A/B/F
FGSB-MEXP-LP-A/B/F
Attachments for 2-Inch Express Exit™ and Low-Profile
Express Exit™
ORDERING INFORMATION
Part Number
Description
Yellow System
Black System
FGS-MTRM-C
FGSB-MTRM-C
2x2 trumpet flare; junction included
Single 2" flex tube attachment; 2" flex tube and a 2x2 junction to attach to Express Exit unit included
5' length
FGS-MEX1-C-5F
FGSB-MEX1-C-5F
10' length
FGS-MEX1-C-10F
FGSB-MEX1-C-10F
15' length
FGS-MEX1-C-15F
FGSB-MEX1-C-15F
Dual 7/8" flex tube attachment;
two lengths of 7/8" flex tube and a 2" junction to attach to Express Exit unit included
(2) 5' lengths
FGS-KT03-C
FGSB-KT03-C
(2) 10' lengths
FGS-KT03-C-10F
FGSB-KT03-C-10F
(3) 15' lengths
FGS-KT03-C-15F
FGSB-KT03-C-15F
318108AE 12/13 www.te.com/enterprise-asia
85
5. FiberGuide System
Designed for low-ceiling or height-restricted environments, the Low-Profile
Express Exit features a front-removable cover and extends only 2 inches above
Express Exit™ Family
Part Drawings
406 mm
(16")
Express Exit 2x4
103 mm
(4.1")
196 mm
(7.7")
200 mm
(7.9")
Bracket,
Express Exit 2x4
4-Inch Express Exit
(FGS-MEXP-E-A/B/F shown attached to 4x4 straight section)
51 mm
(2")
Express Exit
254 mm
(10")
95 mm
(3.75")
125 mm
(4.9")
5. FiberGuide System
Bracket,
Express Exit
147 mm
(5.8")
2-Inch Express Exit
(FGS-MEXP-A/B/F; fits 4x4, 4x6 and 4x12 systems; shown attached to 4x6 straight section)
Low Profile Express Exit
260 mm
(10.25")
51 mm
(2")
132 mm
(5.2")
130 mm
(5.1")
Low-Profile Express Exit
(FGS-MEXP-LP-A/B/F; fits 4x4, 4x6 and 4x12 systems; shown attached to 4x4 straight section)
133 mm
(5.2"
268 mm
(10.6")
47 mm
(1.9")
131 mm
(5.16")
Low-Profile Express Exit Designed Exclusively for 2x6 System
(FGS-MEXP-LP-G shown attached to 2x6 straight section)
86
www.te.com/enterprise-asia 12/13 318108AE
System Support Kits
Ladder Rack Cantilever Support
Bracket Kit
(FGS-HDLB-4)
L Bay Support Bracket Kit
(FGS-HLBK shown alone and
attached to 4x4 FiberGuide)
New Threaded Rod Bracket kit
(FGS-HNTR-XX shown alone and
attached to threaded rod)
Existing Threaded Rod Bracket Kit
(FGS-HETR-XX shown alone and
attached to threaded rod)
Modified New Threaded Rod
Bracket Kit (FGS-HNTR-5/8-A
shown alone and attached to
threaded rod)
Top Support Low Profile
C-bracket Kit
(FGS-HNTS-XX-LP)
Modified Existing Threaded Rod
Bracket Kit
(FGS-HETR-5/8-A shown alone
and attached to threaded rod)
Center Support Bracket Kit
Top Support C-Bracket Kit
(FGS-HNTS-XX)
5. FiberGuide System
For 2x6, 4x4 and 4x6 Systems
(FGS-HTUB-XX)
ORDERING INFORMATION
Description
Part Number
2x6, 4x4, 4x6 system support kits
Ladder rack cantilever support bracket kit
FGS-HDLB-3
L bay support bracket kit
FGS-HLBK
New threaded rod bracket kit; (XX = size: 1/2", 5/8", 12 mm, 14 mm, 16 mm, 18 mm)
Existing threaded rod bracket kit; (XX = size: 1/2", 5/8", 12 mm, 14 mm, 16 mm)
FGS-HNTR-XX
FGS-HETR-XX
Modified new threaded rod bracket kit; 5/8"
FGS-HNTR-5/8-A
Top support low-profile C-bracket kit; (XX = size: 1/2", 5/8", 12 mm, 14 mm, 16 mm)
FGS-HNTS-XX-LP
Top support C-bracket kit; (XX = size: 1/2", 5/8", 12 mm, 14 mm, 16 mm)
Modified existing threaded rod bracket kit; 5/8"
FGS-HNTS-XX
FGS-HETR-5/8-A
Center support bracket kit; (XX = size: 1/2", 5/8", 12 mm, 14 mm, 16 mm, 20 mm)
FGS-HTUB-XX
Digital cableway bracket kit; 305 mm (12")
FGS-HCBL-12
Digital cableway bracket kit; 381 mm (15")
FGS-HCBL-15
Ladder rack center support bracket kit
FGS-HNLR-AB
OMX frame center support bracket kit; 16 mm (.63")
Under floor support bracket kit
FGS-HOMX-16MM
FGS-HUFB-A
Custom brackets are available, please contact TE Connectivity.
318108AE 12/13 www.te.com/enterprise-asia
87
System Support Kits
For 4x12 Systems
Existing Ladder Rack Center
Support Bracket Kit
Trapeze Bracket Kit
(FGS-HNTP-F-XX)
(FGS-HETP-F-XX)
5. FiberGuide System
Top Support Low-Profile
Threaded Rod Bracket Kit
(FGS-HNTS-F-XX-LP shown alone
and attached to threaded rod)
Top Support Threaded Rod
Bracket Kit
(FGS-HNTS-F-XX)
Center Support Threaded Rod
Bracket Kit
(FGS-HTUB-F-XX shown alone
and attached to threaded rod)
New Threaded Rod Bracket Kit
(FGS-HNTR-F-XX)
Existing Threaded Rod
Bracket Kit
(FGS-HETR-F-XX)
ORDERING INFORMATION
Description
Part Number
4x12 system support kits
New ladder rack center support bracket kit
FGS-HNLR-F
Existing ladder rack center support bracket kit;
(XX = size: 1/2", 5/8", 12 mm, 14 mm, 16 mm)
FGS-HETP-F-XX
Trapeze bracket kit; (XX = size: 1/2", 5/8", 12 mm, 14 mm, 16 mm)
FGS-HNTP-F-XX
Center support threaded rod bracket kit;
(XX = size: 1/2", 5/8", 12 mm, 14 mm, 16 mm, 20 mm)
FGS-HTUB-F-XX
Top support low-profile threaded rod C-bracket kit;
(XX = size: 1/2", 5/8", 12 mm, 14 mm, 16 mm)
FGS-HNTS-F-XX-LP
Top support threaded rod C-bracket kit; (XX = size: 1/2", 5/8", 12 mm, 14 mm, 16 mm)
FGS-HNTS-F-XX
New threaded rod bracket kit; (XX = size: 5/8", 14 mm, 16 mm, 18 mm)
FGS-HNTR-F-XX
Existing threaded rod bracket kit; (XX = size: 5/8", 14 mm, 16 mm)
FGS-HETR-F-XX
88
www.te.com/enterprise-asia 12/13 318108AE
System Support Kits
For 4x24 Systems
Variable Fitting Support Locator Kit
– Horizontal Elbow
(FGS-MH4E-H-VS)
Variable Fitting Support Locater Kit –
Horizontal T with Single 12" Exit
(FGS-MHRT-H/F-VS)
Variable Support Bracket - Horiz. Elbow
(FGS-MH4E-H-VS)
Variable Support Bracket - Horiz. T
(FGS-MHRT-H/F-VS)
Variable Fitting Support Locater
Kit – Horizontal Cross
(FGS-MHXP-H-VS)
Variable Fitting Support Locater Kit –
Horizontal Cross with Dual 12" Exits
(FGS-MHXP-F/H-VS)
12.7 mm
(.5")
Variable Support Bracket - Horiz. Cross
(FGS-MHXP-H-VS)
Quick Knob
5. FiberGuide System
Variable Support Bracket - Horiz. Cross
(FGS-MHXP-F/H-VS)
Threaded Rod Ref
Split Nut
Bracket
Clip
Existing Threaded Rod Trapeze Bracket
844.6 mm
(33.25")
736.6 mm
(29")
50.8 mm
(2")
50.8 mm
(2")
793.8 mm
(31.25")
736.6 mm
(29")
Existing 5/8” Threaded Rod Trapeze Bracket Kit
New 5/8” Threaded Rod Trapeze Bracket Kit
(FGS- HETP-H-5/8)
(FGS-HNTP-H-5/8)
ORDERING
ExistingINFORMATION
5/8” Threaded Rod Trapeze Bracket Kit
(FGS- HETP-H-5/8)
New 5/8” Threaded Rod Trapeze Bracket Kit
(FGS-HNTP-H-5/8)
Description
Part Number
4x24 System Support Kits
Variable fitting support locater kit for;
Horizontal elbow
FGS-MH4E-H-VS
Horizontal T with single 12" exit
FGS-MHRT-H/F-VS
Horizontal cross
FGS-MHXP-H-VS
Horizontal cross with dual 12" exits
FGS-MHXP-F/H-VS
Threaded rod trapeze bracket kit for;
Existing; 5/8"
FGS-HETP-H-5/8
New; 5/8"
FGS-HNTP-H-5/8
318108AE 12/13 www.te.com/enterprise-asia
89
System Support Kits
System Accessories
ORDERING INFORMATION
Description
Part Number
Threaded rod
5/8" - 11 x 12"
FGS-HTHR-5/8-12
5/8" - 11 x 30"
FGS-HTHR-5/8-30
5/8" - 11 x 72"
FGS-HTHR-5/8-72
1/2" - 13 x 12"
FGS-HTHR-1/2-12
1/2" - 13 x 30"
FGS-HTHR-1/2-30
1/2" - 13 x 72"
FGS-HTHR-1/2-72
Threaded rod;
(XX = size: 12 mm, 14 mm, 16 mm) (NN = length: 30 cm, 75 cm, 180 cm)
FGS-HTHR-XX-NN
Auxiliary framing kit
2x 9/16" x 3/16" for 5/8" rod
FGS-HFCK-5/8
2x 9/16" x 3/16" for 1/2" rod
FGS-HFCK-1/2
Adjustable angle support brackets with 5/8" threaded rod
11 x 36" rod
FGS-HASB-5/8-36
11 x 48" rod
FGS-HASB-5/8-48
5. FiberGuide System
Adjustable angle support brackets with 1/2" threaded rod
13 x 36" rod
FGS-HASB-1/2-36
13 x 48" rod
FGS-HASB-1/2-48
Ladder rack bracket kit for radiused ladder racking
FGS-HLDR-A
Ladder rack bracket kit; (XX = size: 1/2", 5/8", 12 mm, 14 mm, 16 mm)
FGS-HLDR-XX
Unistrut nut kit; 5/8"
FGS-HDGR
Frame mounting hardware kit; (XX = size: 1/2", 5/8", 12 mm, 14 mm, 16 mm)
FGS-HKFM-XX
Part Number
Trough cover clip kit
Yellow System
Black System
FGS-KT09
FGS-KT09
FGS-MIDY-XF
FGSB-MIDY-XF
FGS-MLDY-XF
FGSB-MLDY-XF
FGS-MFTY-XF
FGSB-MFTY-XF
FGS-MISY-XF
FGSB-MISY-XF
Slotted and solid flex tubes
(X = length: 5, 10, 15, 20, 25, 50,
75, 100, 125, 150, 200, 250)
Hinges; single hinges for 4x4 and 4x6 covers
FGS-HHGK
FGS-HHGK
Retainer rings; kit of 10 – used to retain fibers in 2" flex
tube
FGS-HFRR-10
FGS-HFRR-10
Flex tube clamp; kit of 10 – used to secure 2" flex tube to
2" vertical ducts
FGS-HHEC-10
FGS-HHEC-10
FGS-MSTOR-A/B/F
FGS-MSTOR-A/B/F
FGS-MKIT-ABF
FGS-MKIT-ABF
FGS-MKIT
FGS-MKIT
4x4 system
FGS-HIFC-A
FGS-HIFC-A
4x6 system
FGS-HIFC-B
FGS-HIFC-B
4x12 system
FGS-HIFC-F
FGS-HIFC-F
FGS-KQKB
FGS-KQKB
FGS-HRJA-A/B/F
FGS-HRJA-A/B/F
FGS-MFIN-10
FGS-MFIN-10
Storage spools for dark fiber jumpers; kit of 2
Mitre box with saw
Used to cut 2x2, 4x4, 4x6, and 4x12 FiberGuide®
straight sections to size
Used to cut 2x2, 4x4, and 4x6 FiberGuide
straight sections to size
IFC tie down for;
Quick knobs with T-bolt and cover slip; kit of 10
Reverse junction adapter kit for 4x4, 4x6, and 4x12
systems; used to connect two parts rotated 180°
Retrofit fin; kit of 10
90
www.te.com/enterprise-asia 12/13 318108AE
6. Storage Area Management (SAM)
Optical Cable Management, Simplified!...................................................92
Under-chassis Enclosure & Adaptor Plates............................................93
Hydra Cable Assemblies................................................................................ 94
Far-End Panel Equipment..............................................................................95
Trunk Cable Assemblies................................................................................. 96
318108AE 12/13 www.te.com/enterprise-asia
91
Storage Area Management (SAM)
Optical Cable Management, Simplified!
Your data center is managing more information than ever. This is the
driving force behind the need for more efficient and effective storage
solutions. The increasing complexity of managing a large quantity of
devices and data is escalating the cost of software and services, and is
drawing most of the IT community’s attention. The physical layer drives
much of the complexity associated with installing SAN systems, and many
of the impediments associated with these implementations.
There are a number of challenges with SAN cabling at the physical layer.
High-density port groupings, the sheer volume of patch cords, moves,
adds, and changes, and the ports themselves—installing and tracking the
actual devices and cables connecting them, can all prove to be difficult.
Plus, space is at a premium in most data centers; many have narrow
cabinets or four post racks with inadequate cable management space.
TE’s Storage Area Management (SAM) Solution for network infrastructures
is designed to reduce the bulkiness of cabling and connectors in the data
center by up to 80% and enable high-density deployment with fewer
costly cabinet or infrastructure upgrades. SAM can help you save time,
reduce costs, maximize efficiency, and open up much needed space in
your data center. It takes the complexity out of cable management, and
optimizes the performance of your data center floor space, racks and
electronics.
6. Storage Area Management (SAM)
De-clutter your racks for a highly organized, eco-friendly network infrastructure. SAM delivers operational efficiency to
Storage Area Network (SAN) cabling and can help customers:
• Reduce SAN switch cabling volume by up to 80%
• Implement high-density deployment with
fewer cabinet or infrastructure upgrades
• Simplify installation, upgrades and
migration with dedicated linecard kits
• Improve operational response time
• Reduce space requirements by managing
up to 768 fiber ports within 2 rack units
• Remove and redeploy linecards
in several quick "clicks"
• Minimize footprint—no additional front vertical,
side, or horizontal cable management devices
• Leverage the high density UCP cable management
system with MPOptimate Quick-Fit cassettes
• Deploy in narrow cabinets or racks
and limited space environments
• Can be combined with other MPOptimate products in
the channel within budget limits of the application
• Minimize cable mass and slack management
using linecard-optimized hydra assemblies
• Easily access ports
• Maintain unobstructed linecard maintenance
• Achieve simplified scalability
• Organize with pre-labeled ports
• Speed up deployment and reduce connection
errors with color-coded and keyed connections
92
www.te.com/enterprise-asia 12/13 318108AE
Storage Area Management (SAM)
Under-chassis Enclosure & Adaptor Plates
SAM Rack Mount Optical Fiber Enclosure
FEATURES
• Accepts 12 SAM adaptor plates
• Angled front face for improved visibility and cable management
• Rugged aluminum construction
• Internal guides to ease installation of trunk assemblies
• Adjustable front and rear mounting brackets included
• Panel labelling on rear to simplify location and documentation
• Pre-loaded with 12 blank plates
ORDERING INFORMATION
Description
Part Number
Rack Mount Patch Enclosure, 2U MPO SECURE
1553761-1
SAM MPO Adaptor Plates
6. Storage Area Management (SAM)
FEATURES
• Adaptor counts match 16, 32, 48 and 64-port blades
• Color-coded keying on adaptors minimize risk of improper
mating (keying on hydra side only—trunk side is not keyed)
• Port numbering matches blades
• Robust screw-in mounting system
• Accepts Multi Mode and Single Mode assemblies
ORDERING INFORMATION
Description
Part Number
16-Port blade (2 x MPO secure coupler)
2193050-1
32-Port blade (4 x MPO secure coupler)
2193051-1
48-Port blade (6 x MPO secure coupler)
2193052-1
64-Port blade (8 x MPO secure coupler)
2193016-1
Adaptor Plate Blank with 2 Cable Management rings
2111481-1
318108AE 12/13 www.te.com/enterprise-asia
93
Storage Area Management (SAM)
Hydra Cable Assemblies
SAM Hydra Cable Assemblies
FEATURES
• 8-Port/16-fiber assemblies
• Length optimized for minimum slack
• SECURE MPO or MPOptimate connectors feature color
coded keying for proper mating
• Overmolded LSZH cables
• Uniboot universal pitch LC connectors
• Individually labelled legs
ORDERING INFORMATION
Description
Port Label
MPO Color
Part Number
MPO OS2
Part Number
MPOptimate OM4
Hydra Cable Assembly for 16-Port & 32-Port blade
0-7
green
2160323-1
2160322-1
Hydra Cable Assembly for 16-Port & 32-Port blade
8-15
orange
2160325-1
2160324-1
Hydra Cable Assembly for 32-Port blade
16-23
green
2160323-2
2160322-2
Hydra Cable Assembly for 32-Port blade
24-31
orange
2160325-2
2160324-2
Hydra Cable Assembly for 48-Port blade
0-7
red
2160317-1
2160503-1
6. Storage Area Management (SAM)
Hydra Cable Assembly for 48-Port blade
8-15
yellow
2160319-1
2160318-1
Hydra Cable Assembly for 48-Port blade
16-23
blue
2160321-1
2160320-1
Hydra Cable Assembly for 48-Port blade
24-31
red
2160317-2
2160503-2
Hydra Cable Assembly for 48-Port blade
32-39
yellow
2160319-2
2160318-2
Hydra Cable Assembly for 48-Port blade
40-47
blue
2160321-2
2160320-2
Hydra Cable Assembly for 64-Port blade
0-7
orange
2160386-1
2160385-1
Hydra Cable Assembly for 64-Port blade
8-15
slate
2160388-1
2160387-1
Hydra Cable Assembly for 64-Port blade
16-23
aqua
2160390-1
2160389-1
Hydra Cable Assembly for 64-Port blade
24-31
violet
2160392-1
2160391-1
Hydra Cable Assembly for 64-Port blade
32-39
orange
2160386-2
2160385-2
Hydra Cable Assembly for 64-Port blade
40-47
slate
2160388-2
2160387-2
Hydra Cable Assembly for 64-Port blade
48-55
aqua
2160390-2
2160389-2
Hydra Cable Assembly for 64-Port blade
56-63
violet
2160392-2
2160391-2
94
www.te.com/enterprise-asia 12/13 318108AE
Storage Area Management (SAM)
Far-End Panel Equipment
SAM Far-End MPO/MPOptimate Quick-Fit Cassettes
FEATURES
• 8 port (16 fiber) cassette to replicate 8
SFP ports on director blade
• Rear side: 1 x MPO (to accept one MPO trunk assembly)
Front side: 4 x LC Quad (to accept eight
standard LC duplex assemblies)
• Maintains same port identity and labelling scheme as the
hydra assemblies (including 8 pre-numbered port labels)
• To be used in UCP panels
ORDERING INFORMATION
Description
Part Number
MPOptimate OM4 Quick-Fit cassette
2160270-3
MPO OS2 Quick-Fit cassette
2160270-2
Foldable UCP Patch Panel
6. Storage Area Management (SAM)
Please refer to Chapter 4, page 45
Foldable UCP Patch Panel Angled
Please refer to Chapter 4, page 45
318108AE 12/13 www.te.com/enterprise-asia
95
Storage Area Management (SAM)
Trunk Cable Assemblies
SAM MPO/MPOptimate Trunk Cable Assemblies
FEATURES
• 24-fiber assemblies (16 active when mated to hydras)
provide an upgrade path to 40 and 100 GbE
• Mate with SAM adaptor plates and SAM Quick-Fit cassettes
• Non-keyed MPO interface
• LSZH rated, indoor outdoor loose tube cable
• Pre-tested and ready to install
ORDERING INFORMATION
Description
Part Number
MPOptimate OM4
Y-2160301-X
MPO OS2
Y-2160302-X
Y- -X
Length
0- -2
0- -3
6. Storage Area Management (SAM)
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
Y- -X Length
35 m
4- -6
46 m
5- -7
57 m
6- -8
68 m
7- -9
79 m
9- -0
90 m
36 m
4- -7
47 m
5- -8
58 m
6- -9
69 m
8- -0
80 m
9- -1
91 m
3- -7
37 m
4- -8
48 m
5- -9
59 m
7- -0
70 m
8- -1
81 m
9- -2
92 m
3- -8
38 m
4- -9
49 m
6- -0
60 m
7- -1
71 m
8- 2
82 m
9- -3
93 m
94 m
Y- -X Length
Y- -X
Length
Y- -X
Length
2m
1- -3
13 m
2- -4
24 m
3- -5
3m
1- -4
14 m
2- -5
25 m
3- -6
0- -4
4m
1- -5
15 m
2- -6
26 m
0 -5
5m
1- -6
16 m
2- -7
27 m
0- -6
6m
1- -7
17 m
2- -8
28 m
3- -9
39 m
5- -0
50 m
6- -1
61 m
7- -2
72 m
8- -3
83 m
9- -4
0- -7
7m
1- -8
18 m
2- -9
29 m
4- -0
40 m
5- -1
51 m
6- -2
62 m
7- -3
73 m
8- -4
84 m
9- -5
95 m
0- -8
8m
1- -9
19 m
3- -0
30 m
4- -1
41 m
5- -2
52 m
6- -3
63 m
7- -4
74 m
8- -5
85 m
9- -6
96 m
0- -9
9m
2- -0
20 m
3- -1
31 m
4- -2
42 m
5- -3
53 m
6- -4
64 m
7- -5
75 m
8- -6
86 m
9- -7
97 m
1- -0
10 m
2- -1
21 m
3- -2
32 m
4- -3
43 m
5- -4
54 m
6- -5
65 m
7- -6
76 m
8- -7
87 m
9- -8
98 m
9- -9
99 m
1- -1
11 m
2- -2
22 m
3- -3
33 m
4- -4
44 m
5- -5
55 m
6- -6
66 m
7- -7
77 m
8- -8
88 m
1- -2
12 m
2- -3
23 m
3- -4
34 m
4- -5
45 m
5- -6
56 m
6- -7
67 m
7- -8
78 m
8- -9
89 m
96
www.te.com/enterprise-asia 12/13 318108AE
7. Core VSM System
Management Panels......................................................................................... 98
Copper Solution................................................................................................. 99
Fiber Solution.....................................................................................................101
318108AE 12/13 www.te.com/enterprise-asia
97
Core VSM
Management Panels
Rack Mount Quick-Fit Panel
FEATURES
• Accepts up to 9 Quick-Fit modules
• 3U
• Including cable support bars with tie down options
and Fiber Optic tail over length
Color: Black (RAL 9005) and galvanised finish
ORDERING INFORMATION
Description
Part Number
Rack Mount Quick-Fit Panel
1671907-1
Cable Management Tray
FEATURES
• Optimized to replace Cisco Nexus 7010 switch cable manager
• Provides vertical patch cord guiding
Color: Black (RAL 9005)
7. Core VSM System
ORDERING INFORMATION
Description
Part Number
Cable Management Tray for Cisco Nexus 7010
98
1671633-1
www.te.com/enterprise-asia 12/13 318108AE
Core VSM
Copper Solution
RJ-45 to MRJ21 Quick-Fit Cassettes (1 or 10 Gb/s)
For RJ-45 copper management please use our MRJ21 Quick-Fit cassettes:
- for 10 GbE (XG) see page 26
- for 1 GbE see page 28
MRJ21 to MRJ21 shielded cable assemblies (1 or 10 Gb/s)
For RJ-45 copper management please use our MRJ21 trunk cable assemblies:
7. Core VSM System
- for 10 GbE (XG) see page 27
- for 1 GbE see page 30
318108AE 12/13 www.te.com/enterprise-asia
99
Core VSM
Copper Solution
Category 6A S/FTP Patch Cord RJ-45
FEATURES
• Exceeds Category 6A performance suitable for 10 Gb/s
data transmission
• Category 7 S/FTP stranded cable
• LSZH sheath
• Color-matched snagless boots
• Universal B-wiring
• Specially engineered patch cord length allows one length for all
patch cords in a rack, reducing inventory holding costs
and increasing flexibility for MACs
ORDERING INFORMATION
Description
Part Number
Patch Cord RJ45 Cat. 6A S/FTP, White
2153188-1
Category 6A F/UTP Patch Cord RJ-45
FEATURES
• Exceeds Category 6A performance suitable for 10 Gb/s data transmission
• Category 6A F/UTP stranded cable
• LSZH sheath
• Color-matched snagless boots
7. Core VSM System
• Universal B-wiring
• Specially engineered patch cord length allows one length for all patch cords in a rack,
reducing inventory holding costs and increasing flexibility for MACs
ORDERING INFORMATION
Description
Part Number
Patch Cord RJ45 Cat. 6A F/UTP, White
7-1859666-1
Category 5e F/UTP Patch Cord RJ-45
FEATURES
• Category 5e according to ISO/IEC 11801 and EN-50173-1
• 4 Pair stranded F/UTP cable
• LSZH sheath
• Color-matched snagless boots
• Universal wiring
• Specially engineered patch cord length allows one length
for all patch cords in a rack, reducing inventory holding
costs and increasing flexibility for MACs
ORDERING INFORMATION
Description
Patch Cord RJ45 Cat 5E F/UTP, White
100
Part Number
2153190-1
www.te.com/enterprise-asia 12/13 318108AE
Core VSM
Fiber Solution
LC to MPO Quick-Fit cassettes or MPO to MPO modules
For LC or MPO fiber management please use our
MPOptimate Quick-Fit cassettes and modules
- for MPO to LC Quick-Fit cassettes see page 4
7. Core VSM System
- for MPO Coupler Quick-Fit modules see page 16
MPOptimate pre-terminated trunks
For LC or MPO fiber management please use our MPOptimate
pre-terminated trunks on page 3
MPOptimate patch cords
For LC or MPO fiber management please use our
MPOptimate pre-terminated patch cords on page 5
318108AE 12/13 www.te.com/enterprise-asia
101
Core VSM
Fiber Solution
MPOptimate System LC patch cords
FEATURES
• Patch cords with optimized LC connectors
• Cable performance: OM4 XGA or OM3 XG 10 Gb/s; LSZH construction
Optical performance: Attenuation ≤ 0.15 dB; RL ≥ 35 dB
• Specially engineered patch cord length allows one length for all
patch cords in a rack, reducing inventory holding costs and
increasing flexibility for MACs
ORDERING INFORMATION
Description
Part Number
Patch cord LC Duplex – LC Duplex; OM3 XG 10 Gb/s
2160506-1
Patch cord LC Duplex – LC Duplex; OM4 XGA 10 Gb/s
2160506-2
MPOptimate Fan-Out cable assemblies
FEATURES
• Low loss transition from MPO to LC tails 2 mm
• Terminated with male MPOptimate connectors
• OM4 cable performance, LSZH construction
7. Core VSM System
• Specially engineered fan-out cable length allows one
length for all cable assemblies in a rack, reducing inventory
holding costs and increasing flexibility for MACs
ORDERING INFORMATION
Description
Part Number
MPO male - LC Fan-out OM4 XGA 10 Gb/s for 48 port blade
2160537-1
MPO male - LC Fan-out OM4 XGA 10 Gb/s for 32 port blade
2160538-1
102
www.te.com/enterprise-asia 12/13 318108AE
8. Managed Connectivity
ICM for Quareo Technology........................................................................104
Q4000 Managed Fiber Platform..............................................................105
Quareo Managed Fiber Trunk Cables and Patch Cords..................108
Q2000 Managed Copper Platform..........................................................109
Quareo Managed Copper Patch Cords.................................................... 111
ICM for AMPTRAC Technology................................................................... 112
AMPTRAC Analyzer......................................................................................... 113
AMPTRAC Scanning Module Cables........................................................ 114
AMPTRAC Fiber Platform............................................................................. 115
AMPTRAC Fiber Patch Cords...................................................................... 116
AMPTRAC Copper Platform......................................................................... 117
AMPTRAC Copper Patch Cords................................................................ 122
AMPTRAC Sensor Strips............................................................................... 123
Accessories......................................................................................................... 124
318108AE 12/13 www.te.com/enterprise-asia
103
Managed Connectivity
ICM for Quareo Technology
Quareo Infrastructure Configuration Manager Software
The TE Managed Connectivity software (ICM) supports both AMPTRAC and
Quareo technologies.
Quareo ICM can be used either as a ‘stand alone’ application or as a tool for
integrating valuable Quareo information into third party / custom applications.
As a stand alone retail application ICM provides the following features:
FEATURES
• Fully automated documentation system
• Real time monitoring
• Automatic database update on changes
• Self-discovers Patch Cords
• Event logs and data base reports
• Programmable alerts
• Automated work order processing
• Auto-discovers IP devices
• Automatic re-synchronization on power outages
• User management
• Supports ITIL best practices
• ISO 20000 and BS 15000 compliant
• CSV data import
• Easy to use and intuitive menu structure
ORDERING INFORMATION
8. Managed Connectivity
Description
Part Number
ICM Software; 480 Port License
1591369-1
ICM Software; 2400 Port License
1591369-2
ICM Software; 4800 Port License
1591369-3
ICM Software; 9600 Port License
1591369-4
ICM Software; 24,000 Port License
1591369-5
ICM Software; 48,000 Port License
1591369-6
ICM Software; 96,000 Port License
1591369-7
Alternative port and service packages also available.
104
www.te.com/enterprise-asia 12/13 318108AE
Managed Connectivity
Q4000 Managed Fiber Platform
Quareo forms one of the two hardware base technologies within TE’s Managed Connectivity Solution.
The Fiber solution comprises of fiber network Chassis (1, 2 and 4U), which accommodate 0.5U blades (2, 4 and 8
respectively). Fiber blades support MPO-MPO and MPO-LC configurations. The portfolio is supported by a range of
managed trunks and patch cords.
Q4000 Network Chassis: Q4200, Q4400, Q4800
Q4000 Series Network Chassis featuring Quareo™ Technology allow
network personnel to view, manage and audit the physical layer. This
means, for the first time, the physical layer is now subject to the same
compliance policy as higher layers of the network. With 70% of network
outages attributed to errors made in the physical layer, TE introduces
a new category of products. Simply put, Quareo enables Managed Connectivity using connection point identification
(CPID).
The Quareo Q4000 Series chassis are designed to accommodate the Q3000 blades for an unmanaged solution or the
Q4000 blades for a managed solution utilizing CPID.
FEATURES
• Supports a Q4000 Series Chassis Controller
• User Indicators
Power:Green
Alert: Yellow
Status:Green/Red
• Reset Button
• Trunk and Fan-out brackets supplied
for rear cable management
• Maintenance Services available on this product
PHYSICAL:
Rack Mounting: Grounding: Dimensions (HxWxD): EIA/ETSI/WECO/IEC 60297 19" equipment racks
2-screw grounding location for standard grounding lug
Q4200: 1U, 44.5 mm x 483 mm x 338 mm
(1.75" x 19" x 13.3")
Q4400: 2U, 88.9 mm x 483 mm x 338 mm
(3.5" x 19" x 13.3")
Q4800: 4U, 177.8 mm x 483 mm x 338 mm
(7" x 19" x 13.3")
ENVIRONMENTAL:
Operating Temperature: Storage Temperature: Humidity: -10 °C to +60° C (+14 °F to +140° F)
-40 °C to +85° C (-40°F to +185° F)
5% to 95% non-condensing
RoHS Compliant
Safety: Flammability:
EMC:
(UL), c(UL), CE, A-TICK
(UL) 94 V-0
UL 1863
EMC Directive, 2004/108/EEC
8. Managed Connectivity
SPECIFICATIONS
ORDERING INFORMATION
Description
Part Number
Q4200 (2 blades); 1U Network Chassis, accommodates 2 each Q4000 series blades
QCH-1RU
Q4400 (4 blades); 2U Network Chassis, accommodates 4 each Q4000 series blades
QCH-2RU
Q4800 (8 blades); 4U Network Chassis, accommodates 8 each Q4000 series blades
QCH-4RU
318108AE 12/13 www.te.com/enterprise-asia
105
Managed Connectivity
Q4000 Managed Fiber Platform
Q4000 Network Chassis: QCC-4 Chassis Controller
The QCC-4 Chassis Controller is compatible with Q4000 Series Chassis.
FEATURES
• Supports a Q4000 Series Chassis
• User Indicators
Ethernet Link: Green
Ethernet Activity: Yellow
• Maintenance Services available on this product
SPECIFICATIONS
PHYSICAL:
Dimensions (HxWxD):
25.2 mm x 87.9 mm x 124.7 mm
(0.99"x 3.46"x 4.91")
Electrical I/F:RJ45
Electrical Aux. I/F:
2-Pin Micro-Fit 3.0™
8. Managed Connectivity
ENVIRONMENTAL:
Operating Temperature: Storage Temperature: Humidity:
-10° C to +60° C (+14° F to +140° F)
-40° C to +85° C (-40° F to +185° F)
5% to 95% non-condensing
RoHS Compliant
ELECTRICAL:
PoE Power: Auxiliary input Power: IEEE 802.3af Class 0
+48VDC @ 270mA
Safety: EMC:
(UL), c(UL), CE, A-TICK
UL 1863
EMC Directive, 2004/108/EEC
Supports 10Base-T and 100Base-TX
Network:
ORDERING INFORMATION
Description
Part Number
QCC-4; Chassis Controller for Q4000 Network Chassis
QCPU-MCBM
106
www.te.com/enterprise-asia 12/13 318108AE
Managed Connectivity
Q4000 Managed Fiber Platform
Q4000 Blades
COMMON FEATURES
• Available in multimode and singlemode
• Blade Controller is hot swappable in blade
• Front cable management with removable designation labels
• Rear cable management tie down points to work with
Q4000 Series Network Chassis Rear Cable Management
• Blade remains powered when extended to the first position
• User Indicators Blade Controller (LED)
Power: Green
Alert: Yellow/Green
• User Indicators Blade (LED) Duplex Ports: Yellow/Green
• Maintenance services are available
FEATURES
• 0.5U blade
• 16 MPO ports on MPO-to-MPO blade
• 24 Duplex LC ports distributed from 2EA 12 fiber MPO cables on LC-to-MPO blade
• Supports Quareo enabled and standard 12 fiber MPO cables
• Supports Quareo enabled and standard LC-LC duplex patch cords
• Requires 1EA QBC-4 Blade Controller (ships with Blade)
SPECIFICATIONS
19.3 mm x 438.4 mm x 373.1 mm (0.76” x 17.26" x 14.69”)
ENVIRONMENTAL
Operating Temperature: Storage Temperature: Humidity: -10° C to +60° C (+14° F to +140° F)
-40° C to +85° C (-40° F to +185° F)
5% to 95% non-condensing
ELECTRICAL
Input Power: Optical Interface
MPO-to-MPO:
LC-to-MPO:
COMPLIANCE
Safety: Flammability: EMC:
8. Managed Connectivity
PHYSICAL
Dimensions (HxWxD): 1.0 W Max.
12 Fiber MPO
Duplex LC (front), 12 Fiber MPO (rear)
RoHS Compliant
(UL), c(UL), CE, A-TICK
(UL) 94 V-0
UL 1863
EMC Directive, 2004/108/EEC
ORDERING INFORMATION
Description
Part Number
Chassis Blade Fiber; 16 Port (192 Fiber), MPO-to-MPO
Multimode
QFB-192FMPOMMHR
Singlemode
QFB-192FMPOSMHR
Chassis Blade Fiber; 24 Port (48 Fiber), LC-to-MPO
Multimode
QFB-48FDLCMMMHR
Singlemode
QFB-48FDLCMSMHR
Blank Blade Cover for Empty Blade Position Q4000/Q3000
318108AE 12/13 www.te.com/enterprise-asia
QBCB-HR
107
Managed Connectivity
Quareo Managed Fiber Trunk Cables and Patch Cords
Quareo MPO-to-MPO Trunk Cables
FEATURES
• Plug-and-Play Cables to connect active equipment into the network
• Round design eliminates preferential bend issues which results
in increased density and greater manageability
• Performance Specifications:OM3/OM4: Attenuation ≤ 0.7 dB (max); RL ≥ 20 dB (min)
OS2: Attenuation ≤ 1.0 dB (max); RL ≥ 55 dB (min)
ORDERING INFORMATION
Product Description
Fiber Type
Singlemode
12 FIber
LSZH
Multimode
Singlemode
24 FIber
LSZH
Multimode
Singlemode
48 FIber
LSZH
Multimode
Singlemode
96 FIber
LSZH
Multimode
Part Number
OS2
Trunk
MPO-to-MPO
QFA-1WWSMZNXXXMAA
OM3
Trunk
MPO-to-MPO
QFA-1FFM3ZNXXXMAA
OM4
Trunk
MPO-to-MPO
QFA-1FFM4ZNXXXMAA
QFA-2WWSMZNXXXMAA
OS2
Trunk
MPO-to-MPO
OM3
Trunk
MPO-to-MPO
QFA-2FFM3ZNXXXMAA
OM4
Trunk
MPO-to-MPO
QFA-2FFM4ZNXXXMAA
OS2
Trunk
MPO-to-MPO
QFA-4WWSMZNXXXMAA
OM3
Trunk
MPO-to-MPO
QFA-4FFM3ZNXXXMAA
OM4
Trunk
MPO-to-MPO
QFA-4FFM4ZNXXXMAA
OS2
Trunk
MPO-to-MPO
QFA-8WWSMZNXXXMAA
OM3
Trunk
MPO-to-MPO
QFA-8FFM3ZNXXXMAA
OM4
Trunk
MPO-to-MPO
QFA-8FFM4ZNXXXMAA
Replace XXX with desired length in Meters. Example 001 for 1 m, 010 for 10 m. Additional configurations available upon request
Quareo Fiber Patch Cords
8. Managed Connectivity
FEATURES
• Managed Fiber cables feature Quareo Technology with
connection point identification
• Can be used in cross-connect, test, or equipment areas
• Standard Lengths: 1, 2, 3, 5 and 10 m
• Standard Colors: Aqua for multimode, Yellow for Singlemode
• Standard Materials: LSZH (plenum also available)
• Performance Specifications: OM3/OM4: Attenuation ≤ 0.3 dB (max); RL ≥ 20 dB (min)
OS2: Attenuation ≤ 0.3 dB (max); RL ≥ 55 dB (min)
ORDERING INFORMATION
Product Description
Fiber Type
OM3
LC-LC
Multimode
OM4
LSZH
SInglemode
OS2
Polarity
Part Number
A-to-A
QFPC-MPPM3ZAXXXM
A-to-B
QFPC-MPPM3ZBXXXM
A-to-A
QFPC-MPPM4ZAXXXM
A-to-B
QFPC-MPPM4ZBXXXM
A-to-A
QFPC-MKKSMZAXXXM
A-to-B
QFPC-MKKSMZBXXXM
Replace XXX with desired length in meters E.G 001 for 1m. Other materials available upon request.
108
www.te.com/enterprise-asia 12/13 318108AE
Managed Connectivity
Q2000 Managed Copper Platform
Quareo forms one of the two hardware base technologies within TE’s Managed Connectivity Solution.
The Copper solution comprises of patch panel (1 and 2U) in shielded and unshielded variants and is
supported by a range of managed network cables.
Patch Panels: Q2324 and Q2348
Q2000 Series Patch Panels featuring Quareo Technology allow network
personnel to view, manage and audit the physical layer. This means, for the
first time, the physical layer is now subject to the same compliance policy
as higher layers of the network. With 70% of network outages attributed to
errors made in the physical layer, TE introduces a new category of products.
Simply put, Quareo enables managed connectivity using connection point
identification (CPID).
FEATURES
• Quareo enabled functionality with dual color port illumination via LEDs
• Integral cable management bar
• 45° IDC contacts providing secure, gas-tight connections
• Accepts 110 style termination tools
• Universal 568A/B wiring
• Discrete labeling system
• Maintenance services available on this product
SPECIFICATIONS
EIA/ETSI/WECO/IEC 60297 19“ equipment racks
Q2324, 1U: 44.5 mm x 483 mm x 120 mm (1.75“ x 19“ x 4.75“)
Q2348, 2U: 88.9 mm x 483 mm x 120 mm (3.50“ x 19“ x 4.75“)
ENVIRONMENTAL
Operating temperature:
-40° to 70° C (104 to 158° F)
Number of plug insertions:
≥750 (IEC/EN 60603-7)
Diameter range:
solid and stranded copper conductors: 26AWG to 22 AWG (0.4 mm dia to 0.6 mm dia)
solid core cable and 24AWG stranded cable.
Wire insulation diameter range:
1.04 mm to 1.60 mm (0.041” x 0.063”)
Insulation resistance:
at 40°C and 93% RH ≥500 MΩ
Contact resistance:
≤1 mΩ typical
Contact re-terminations:
≥200
COMPLIANCE
UL/CSA Approved, CE, A-TICK
UL 94 V-0
UL1863
RoHS compliant
Performance to ANSI/TIA-568-C.2 and ISO 11801, Edition 2 for Category
6/Class E and Category 6A /Class E A .
Independently certified.
RJ socket, 8 positions FCC Part (IEC 60603-7)
ORDERING INFORMATION
Description
Part Number
Q2324; 24 Port Patch panel WITH jacks, Cat. 6A, UTP
QCPP-24MC6AU
Q2348; 48 Port Patch Panel WITH jacks, Cat. 6A, UTP
QCPP-48MC6AU
Q2324; 24 Port Patch Panel WITH jacks, Cat. 6A, STP
QCPP-24MC6AS
Q2348; 48 Port Patch Panel WITH jacks, Cat. 6A, STP
QCPP-48MC6AS
318108AE 12/13 www.te.com/enterprise-asia
109
8. Managed Connectivity
PHYSICAL:
Rack Mounting: Dimensions (HxWxD): Managed Connectivity
Q2000 Managed Copper Platform
QPC-2 Panel Controller Compatible
with Q2000 Patch Panels
FEATURES
• Panel controller operates with the Q2000 family of Network Patch Panels
• Designed to fit inside the rear cable manager without interfering
with panel connectivity, does not require additional rack space
• Power can be supplied through IEEE 802.3af compliant switch port or
additional auxiliary power supply (can be simultaneous)
• Link and activity status LEDs at the rear of unit
• Seamless power transition from PoE to aux supply
• Maintenance services available on this product
SPECIFICATIONS
Product Dimensions (HxWxD):
21 mm x 143 mm x 105 mm (0.82" x 5.62" x 4.142")
Environmental:
Operating Temperature:
-10° C to +60° C (+14° F to +140° F)
Compliance
Flammability:
(UL) 94 V-0
RoHS Compliant
UL/CSA Approved, CE, C-TICK
Conformance with 8 way modular (RJ45) jack requirements according to IEC60603-7 series and TIA/EIA-968-A (FCC 68.500)
Alternate Input Power:
Alternate power source to comply with AC/DC desktop power supply brick.
Minimum requirements:
Input Voltage: 100-240VAC, 50-60Hz, 0.5A
Output Voltage: 48VDC, 0.4A
8. Managed Connectivity
ORDERING INFORMATION
Description
Part Number
QPC-2; Panel Controller for Q2000 Patch Panels
110
www.te.com/enterprise-asia 12/13 318108AE
QCPU-MPPM-1
Managed Connectivity
Quareo Managed Copper Patch Cords
Category 6A U/UTP and S/FTP
These managed cables exceed all performance
requirements for Augmented Category 6 (Cat 6A).
The plug is designed with integrated strain relievers that
prevent the cable from moving at the termination point
when the cable is flexed, safeguarding circuit integrity
and guaranteeing maximum performance. The strain
relievers also ensure that proper bend radii are maintained
throughout the network.
FEATURES
• Quareo Technology with connection point identification
• Connector Interface: Plug type RJ45 shielded/unshielded that conforms to 8 way
modular RJ45 Jack according with IEC 60603-7 series and TIA/EIA-968-A.
• Latch Type: Snag-less
• Boot: Flexible with built in strain relief to maintain proper bend radius
• Wiring Configuration: T568A, T568B and Cross-over
SPECIFICATIONS
ELECTRICAL
ANSI/TIA-568-C.2 and ISO 11801, Edition 2 Category 6A/Class Ea
Category 6, 5e, 5 and 3 backward compatible
-10° C to +60° C
-0° C to +50° C
5% to 90% non-condensing
5% to 95% non-condensing
8. Managed Connectivity
ENVIRONMENTAL
Controlled Environment
GR-63, Section 4.1.2
Operating Temperature: Storage Temperature:
Relative Humidity:
Relative Humidity:
COMPLIANCE
UL 94 V-0
TICK N355
C(UL)us 49S3
CE
RoHS and WEEE 2002/95/EC Directive on the restriction of the use of certain
hazardous substances in electrical and electronic equipment
ORDERING INFORMATION
Description
Category 6A U/UTP Managed Copper Cable
Category 6A S/FTP Managed Copper Cable
Available Colors
Replace XX
Available Lengths
Replace YY
BL = Blue
RD = Red
OR = Orange
GY = Grey
GN = Green
WT = White
YL = Yellow
01 = 1 m
02 = 2 m
03 = 3 m
05 = 5 m
07.5 = 7.5 m
10 = 10 m
Part Number
LSZH
T568B
QCPC-6ARUZB-XXYYM
LSZH
T568B
QCPC-6ARSZB-XXYYM
Note: Not all S/FTP types available in all colors. Please check with Customer Services.
Additional lengths, wiring schemes and shielding types available upon request.
318108AE 12/13 www.te.com/enterprise-asia
111
Managed Connectivity
ICM for AMPTRAC Technology
AMPTRAC Infrastructure Configuration Manager Software
FEATURES
• Fully automated documentation system
• Real time monitoring
• Automatic database update on changes
• Self-discovers Patch Cords
• Event logs and data base reports
• Programmable alerts
• Automated work order processing
• Auto-discovers IP devices
• Automatic re-synchronization on power outages
• User management
• Supports ITIL best practices
• ISO 20000 and BS 15000 compliant
• CSV data import
• Easy to use and intuitive menu structure
ORDERING INFORMATION
Description
Part Number
ICM Software License
Sold with Analyzer
8. Managed Connectivity
112
www.te.com/enterprise-asia 12/13 318108AE
Managed Connectivity
AMPTRAC Analyzer
AMPTRAC Analyzers
FEATURES
• Adds the physical layer to your network documentation system
• Universal analyzer design
- Analyzer can be configured as a master or slave unit
- Any unit can directly communicate to database server
or through another analyzer
- Virtually unlimited in number of ports/drops which can
be monitored
• Very flexible design and implementation allowing for use in
office buildings, data centers and remote/branch offices
• Analyzers sold with AMPTRAC ICM Software license
• Available in 384 port, 768 port or 1152 port versions (19”, 1U)
• Shallow depth at 6.25” (160 mm)
• Suitable for shelve or 19” rack or cabinet mounting
• Large 4 line LCD display providing interactive communications with the database
• Use of latest and current circuitry design
• Minimum heat dissipation - no concerns over heat management in rack or cabinet
• Low power consumption and long lifetime
• Dual external PSUs supported
Remote Scanning module required
Description
Part Number
AMPTRAC ANALYZER HD 1152 (ICM Included)
1-1591360-1
AMPTRAC ANALYZER HD 768 (ICM Included)
2-1591360-3
AMPTRAC ANALYZER HD 384 (ICM Included)
3-1591360-1
Additional External PSU
1-1591364-0
Scanning Module
1-1591363-0
ICM also available without analyzer. Ask TE for more details
318108AE 12/13 www.te.com/enterprise-asia
113
8. Managed Connectivity
ORDERING INFORMATION
Managed Connectivity
AMPTRAC Scanning Module Cables
AMPTRAC Scanning Module Cable Assemblies
Every patch panel or switch port has a copper sensor pad
associated with it. All sensor pads are connected to the AMPTRAC
analyzer via a scanning module and scanning module cable. The
scanning module has two types of connector, an RJ45 connector,
which is used to connect the module to the analyzer via a
standard Category 5 or Category 6 patch cable and a 2.0mm
AMPMODU connector, which connects the module to the switch or
patch panel via the scanning module cable. For monitored devices
of less than 24 ports, multiple cables can be inserted into the
AMPMODU connector equal to the 24 port total. Each scanning
module cable is between 2-4 feet long allowing the scanning
module to be located on the left or the right and be secured on
the cable support management bar or onto the rack/cabinet.
ORDERING INFORMATION
Description
# Positions
AMPTRAC patch panels utilizing the 6-position SL Interface Module, i.e. SL
panels, HD Panels, Quick‑Fit Panels; 110 Plug-n-Play to 2.0mm MODU Latching
Length (ft)
Part Number
24
2
2111440-2
24
2
2111441-2
24
4
2111441-4
AMPTRAC MRJ-21 patch panels, AMPTRAC Ready patch panels
(front attachment), ACO; HD-22 to 2.0mm MODU Latching
24
2
2111442-2
AMPTRAC Fiber Optic MPO Cassettes; RJ-11 to 2.0mm MODU Non-Latching
6
1.5
2111443-1
AMPTRAC MRJ21 XG quick fit Cassette
8
2
2153175-2
2
4
2111444-4
6
4
2111445-4
8
4
2111446-4
12
4
2111447-4
16
4
2111448-4
24-port Sensor Strips for electronics, AMPTRAC Ready and 7AS Panels
(rear attachment); 2.0 mm MODU to 2.0mm MODU Latching
8. Managed Connectivity
AMPTRAC Sensor Strips for LAN electronics based on #
positions; 2.0 mm MODU to 2.0mm MODU Non-Latching
114
www.te.com/enterprise-asia 12/13 318108AE
Managed Connectivity
AMPTRAC Fiber Platform
AMPTRAC Optical Fiber Patch Panels
FEATURES
• Available for LC Duplex and SC Duplex systems
• Available in OM3, OM4 and singlemode
• Support field termination or use with MPO cassettes
• Duplex LC SL Series inserts sold separately.
ORDERING INFORMATION
Part Number
Snap-In SC Adaptor Plate, 6 ports (12 fibers); Fiber Type: Multimode (beige)
1435657-1
Snap-In SC Adaptor Plate, 6 ports (12 fibers); Fiber Type: Singlemode (blue)
1435657-2
Snap-In SC Adaptor Plate, 6 ports (12 fibers); Fiber Type: Singlemode APC (green)
1435657-3
MPO/SC Snap-In Cassette, 6 ports (12 fibers); Pairs: straight; Fiber Type: OM3 XG 10 Gb/s
1435688-1
MPO/SC Snap-In Cassette, 6 ports (12 fibers); Pairs: flipped; Fiber Type: OM3 XG 10 Gb/s
1435688-2
MPO/SC Snap-In Cassette, 6 ports (12 fibers); Pairs: straight; Fiber Type: Singlemode
1435689-1
MPO/SC Snap-In Cassette, 6 ports (12 fibers); Pairs: flipped; Fiber Type: Singlemode
1435689-2
MPO/LC Quick-Fit Cassette, 6 ports (12 fibers); Pairs: straight; Fiber Type: OM3 XG 10 Gb/s
MPO/LC Quick-Fit Cassette, 6 ports (12 fibers); Pairs: flipped; Fiber Type: OM3 XG 10 Gb/s
MPO/LC Quick-Fit Cassette, 6 ports (12 fibers); Pairs: straight; Fiber Type: Singlemode
MPO/LC Quick-Fit Cassette, 6 ports (12 fibers); Pairs: flipped; Fiber Type: Singlemode
MPOptimate/LC Quick-Fit Cassette, 6 ports (12 fibers); Pairs: straight; Fiber Type: OM4
MPOptimate/LC Quick-Fit Cassette, 6 ports (12 fibers); Pairs: flipped; Fiber Type: OM4
1671209-3
1-1671209-3
1671209-4
1-1671209-4
1671229-5
1-1671229-5
LC AMPTRAC Quick-Fit Module, 6 ports (12 fibers); Fiber Type: OM3 XG 10 Gb/s
1933420-2
LC AMPTRAC Quick-Fit Module, 6 ports (12 fibers); Fiber Type: SM
1933420-3
1U drawer loaded with 24 LC Duplex AMTRAC Inserts (48 fibers); Fiber Type: Singlemode
1671149-1
1U drawer for loaded with 24 LC Duplex AMTRAC Inserts (48 fibers); Fiber Type: OM3 XG 10 Gb/s
1671149-3
1U Drawer for 4 MPO AMPTRAC Quick-Fit Cassettes or Quick-Fit modules
1671149-5
·
LC AMPTRAC Quick-Fit module
MPO AMPTRAC
Cassette
(6 x LC Duplex)
(for MPO/
MPOptimate QuickFit Cassettes)
318108AE 12/13 www.te.com/enterprise-asia
115
8. Managed Connectivity
Description
Managed Connectivity
AMPTRAC Fiber Patch Cords
AMPTRAC Fiber Optic Patch Cords
FEATURES
• Exceeds optical performance specifications for OM3, OM4 and single mode
• Patch Cord assemblies contain copper conductor connected to external pin
• External pin makes contact with sensor pad on Patch Panel or switch
• Cable is a mini-tri-zip design for flexibility and small size
LC DUPLEX
• Available for LC Duplex and SC Duplex assemblies
• MPOptimate Optical performance:
Attenuation :IL ≤ 0.15dB, Return Loss: RL ≥ 35dB
• SM Optical performance:
Attenuation: IL ≤0.5 dB, return Loss: RL ≥20dB
SC DUPLEX
ORDERING INFORMATION
Description
Part Number
LC Duplex to LC Duplex; MPOptimate OM4
Y-2160052-X
Y- -X
Length
LC Duplex to LC Duplex; OM3 XG 10 Gb/s
Y-2055438-X
0- -1
1m
LC Duplex to LC Duplex; Singlemode
Y-1435791-X
0- -2
2m
LC Duplex to SC Duplex; OM3 XG 10 Gb/s
Y-1435796-X
0- -3
3m
LC Duplex to SC Duplex; Singlemode
Y-1435797-X
0- -5
5m
SC Duplex to SC Duplex; OM3 XG 10 Gb/s
Y-1435725-X
0- -7
7m
SC Duplex to SC Duplex; Singlemode
Y-1435726-X
1- -0
10 m
8. Managed Connectivity
116
www.te.com/enterprise-asia 12/13 318108AE
Managed Connectivity
AMPTRAC Copper Platform
MRJ21 XG Quick-Fit AMPTRAC Cassette 8 Port (10 Gb/s)
FEATURES
• Adds AMPTRAC functionality to MRJ21 XG cabling
• Compatible to MRJ21 XG cable assemblies for 10GbE performance
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
MRJ21 XG Quick-Fit AMPTRAC cassette for 10GBase-T
2153091-1
MRJ21 XG 19” AMPTRAC Patch Panel, 1U, straight
FEATURES
• Adds AMPTRAC functionality to MRJ21 XG cabling
• Factory terminated and tested solution
• Compatible with MRJ21 XG cable assemblies
for 10GbE performance
• Straight panel with either 24 or 48 ports on 1U
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
2153040-1
Straight AMPTRAC panel 1U for 10GbE; MRJ21 Plugs: 12; RJ-45 Ports: 48
2153049-1
8. Managed Connectivity
Straight AMPTRAC panel 1U for 10GbE; MRJ21 Plugs: 6; RJ-45 Ports: 24
MRJ21 AMPTRAC Patch Panels
FEATURES
• High-density, small form factor connectivity
• Factory terminated and tested
• Modular, pluggable design
• 4 pair MRJ21 Patch Panels for 10Base, 100Base-T and 1000Base-T
• 2 pair MRJ21 Patch Panels for 10Base and 100Base-T
ORDERING INFORMATION
Description
Part Number
Shielded 24 port straight Patch Panel; 4 pair (10/100/1000Base-T)
1711944-2
Unshielded 24 port straight Patch Panel;
4 pair (10/100/1000Base-T)
1777029-2
Unshielded 48 port straight Patch Panel;
4 pair (10/100/1000Base-T)
1777041-1
Unshielded 48 port straight Patch Panel; 2 pair (10/100Base-T)
1777042-1
Unshielded 48 port angled Patch Panel;
4 pair (10/100/1000Base-T)
1777053-1
318108AE 12/13 www.te.com/enterprise-asia
117
Managed Connectivity
AMPTRAC Copper Platform
Category 6 - AMPTRAC PCB Patch Panel (STP)
FEATURES
• 19”, 1U, RJ-45 Patch Panel with 24 ports
• Category 6 Pyramid tested
• LSA-Plus® tool compatible enhanced 110 IDC blocks
• 10 Gigabit Ethernet ready
• Rear cable management
• Cover adapts to different cable diameters via variable snap-in position
• Shield connection separated from strain relief
• Including grounding bolt
• Universal wiring - T568 A or B wiring pattern
• Protected PCB
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Shielded Cat. 6 Full AMPTRAC 24 port Patch Panel, Color: black
1644042-1
Category 6 - AMPTRAC PCB Patch Panel (UTP)
FEATURES
• 19”, 1U, RJ-45 Patch Panel with 24 ports
• Category 6 Pyramid tested
8. Managed Connectivity
• LSA-Plus® tool compatible enhanced 110 IDC blocks
• 10 Gigabit Ethernet ready
• Rear cable management
• Including grounding bolt
• Universal wiring - T568 A or B wiring pattern
• Protected PCB
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Unshielded Cat. 6 Full AMPTRAC 24 port Patch Panel, Color: black
118
1711147-1
www.te.com/enterprise-asia 12/13 318108AE
Managed Connectivity
AMPTRAC Copper Platform
STP/UTP SL 110C Jack Patch Panels (w/o Rear Cable Management)
FEATURES
• Available in standard straight version or in angled version
for improved cable and space management
• Uses AMP NETCONNECT high-performance
SL Series 110C Modular Jacks
• I/O connection made with 110C PlugnPlay Cable Assembly
• Cost-effective AMPTRAC Ready! solution: install AMPTRAC
Patch Panels now and analyzer and software later
• Category 6 Patch Panels come with Modular Jacks
bagged separately (unloaded) for field termination
with SL Series Modular Jack Termination Tool.
ORDERING INFORMATION
Description
Part Number
Unshielded Cat. 6, 24 port panel; Type: Straight; Height: 1U
1933327-1
Unshielded Cat. 6, 48 port panel; Type: Straight; Height: 2U
1933328-1
Unshielded Cat. 6, 24 port panel; Type: Angled; Height: 1U
1933329-1
Unshielded Cat. 6, 48 port panel; Type: Angled; Height: 2U
1933330-1
Shielded XG 24 Port Panel; Type: Straight; Height: 1U
1933331-1
Shielded XG 48 Port Panel; Type: Straight; Height: 2U
1933332-1
Shielded XG 24 Port Panel; Type: Angled; Height: 1U
1933333-1
Shielded XG 48 Port Panel; Type: Angled; Height: 2U
1933334-1
8. Managed Connectivity
Category 3 - AMPTRAC Ready! 50 Port Telephone Patch Panel
FEATURES
• 19”, 1U, Telephone Panel with 50 ports
• AMPTRAC Ready! high-end version
• Active Pin-out: 36.45
• Conductor diameter range from AWG 26-22 (0.4-0.65 mm)
• Easy upgrade to AMPTRAC Infrastructure Management
• Rear cable management for multipair cables
• 110Connect blocks for conductor insulation diameters up to 1.28 mm
ORDERING INFORMATION
Description
Part Number
AMPTRAC Ready! 50 port panel; Color: light gray (RAL 7035)
1394060-1
AMPTRAC Ready! 50 port panel; Color: black (RAL 9005)
1394060-2
I/O upgrade kit to full AMPTRAC
1435954-1
318108AE 12/13 www.te.com/enterprise-asia
119
Managed Connectivity
AMPTRAC Copper Platform
STP & UTP Quick-Fit Modules
FEATURES
• Used to add AMPTRAC functionality to AMP-TWIST SL Jack cabling
• STP version has automatic bonding by design
• Labels included
• Set of 4 modules
ORDERING INFORMATION
Description
Part Number
STP AMPTRAC ready Quick-Fit module (4 pcs)
1933196-1
UTP AMPTRAC ready Quick-Fit module (4 pcs)
1933197-1
Angled AMPTRAC Modular Quick-Fit Panel (unloaded)
FEATURES
• 19” 1U angled modular Patch Panel to be equipped with
different SlimLine jacks without dust cover
• Adjustable & removable rear cable bracket incl. easy to use
cable organizing CaRe-clips
• Including grounding bolt
Color: black (RAL 9005)
ORDERING INFORMATION
8. Managed Connectivity
Description
Part Number
Angled Full AMPTRAC Modular panel for UTP SL Jacks
1-1671136-3
Angled Full AMPTRAC Modular panel for STP SL Jacks
1-1671136-4
Flushmount AMPTRAC Modular Quick-Fit Panel (unloaded)
FEATURES
• 19” 1U unloaded flushmount panel to be
equipped with different SlimLine jacks
• Suitable for UTP and STP jacks
• Including grounding bolt
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Flushmount Full AMPTRAC Modular Panel
1-1671187-1
120
www.te.com/enterprise-asia 12/13 318108AE
Managed Connectivity
AMPTRAC Copper Platform
Flushmount AMPTRAC Standard Patch Panel (unloaded)
FEATURES
• 19” unloaded flushmount Patch Panel to be
equipped with different SlimLine jacks
• Full AMPTRAC
• Accepts up to 24 SL Jacks without dust cover
• Including grounding bolt
ORDERING INFORMATION
Description
Part Number
Full AMPTRAC unloaded Panel for AMPTWIST 6 jacks; Color: black (RAL 9005)
1711685-4
Full AMPTRAC unloaded Panel for AMPTWIST 7 jacks; Color: black (RAL 9005)
1711742-1
AMPTRAC Scanning Module Upgrade Kit for 1U Patch Panels
FEATURES
• Brings AMPTRAC functionality to AMPTRAC Ready! Patch Panels
• Front and rear Scanning Module cable connection
ORDERING INFORMATION
Part Number
AMPTRAC Upgrade Kit with front Scanning Module port, Color: black
1711148-1
AMPTRAC Upgrade Kit with rear Scanning Module port, Color: black
1711148-4
AMPTRAC Cat. 7 AS Upgrade Kit with rear
Scanning Module port; Color: black
1711749-1
318108AE 12/13 www.te.com/enterprise-asia
8. Managed Connectivity
Description
121
Managed Connectivity
AMPTRAC Copper Patch Cords
Twisted Pair Patch Cords Assemblies
FEATURES
• Patch Cord assemblies contain 9th conductor
that is connected to external probe molded
into the modular plug boot
• External probe makes contact with sensor
pad on Patch Panel or switch
• Off-center probe designed to accommodate
stacked-jack LAN switch configurations
• LSZH jacket
• Over-molded snagless boots
Color: white
ORDERING INFORMATION
Description
Performance
Part Number
4pr AMPTRAC: AMP-TWIST 7AS to AMP-TWIST 7AS; LSZH S/FTP
Cat. 7A/ Class FA
Y-1711755-X
4pr AMPTRAC: AMP-TWIST 7AS to RJ-45; LSZH S/FTP
Cat. 6A/ Class EA
Y-1711756-X
Y- -X
Length
0- -1
1m
0- -2
2m
0- -3
3m
0- -5
5m
8. Managed Connectivity
4pr AMPTRAC: RJ-45 to RJ-45; LSZH S/FTP
Cat. 6/ Class EA
Y-1711548-X
2pr AMPTRAC: AMP-TWIST 7AS to RJ-45, Ethernet pinout 1236;
LSZH S/FTP
Cat. 5E/ Class D
Y-1711757-X
2pr AMPTRAC: AMP-TWIST 7AS to RJ-45, ISDN pinout 3645;
LSZH S/FTP
Cat. 5E/ Class D
Y-1711760-X
4pr AMPTRAC: RJ-45 to RJ-45; LSZH UTP, 1 m
Cat. 6/ Class EA
1711351-5
4pr AMPTRAC: RJ-45 to RJ-45; LSZH UTP, 2 m
Cat. 6/ Class EA
1711351-6
4pr AMPTRAC: RJ-45 to RJ-45; LSZH UTP, 3 m
Cat. 6/ Class EA
1711351-7
4pr AMPTRAC: RJ-45 to RJ-45; LSZH UTP, 5 m
Cat. 6/ Class EA
1711351-8
122
www.te.com/enterprise-asia 12/13 318108AE
Managed Connectivity
AMPTRAC Sensor Strips
Sensor Strips for LAN Electronics
FEATURES
• Sensor strips are readily available for a number
of LAN electronic equipment types
• Easy mounting and installation
• The below Product Parts shows a selection
of commonly used switch models
• Custom sensor strips can be designed on request to work
with other LAN electronic equipment (LAN equipment
manufacturer, model number, and model revision are required
in determining the selection of the proper sensor strip)
Important note: Port footprint of LAN electronic model may be
changed by manufacturer without notification! To prevent sensor
pad mismatch, always double-check your actual LAN electronics
model with scaled sensor strip template (PDF). For switch
models not listed or additional information ask your local AMP
NETCONNECT sales contact.
ORDERING INFORMATION
Part Number
Ports per Strip: 24; Typical Switch: CISCO 4000 and 6000, 48-Port Blades
1435346-1
Ports per Strip: 24; Typical Switch: CISCO 3500 and 4548, 48-Port
1435346-4
Ports per Strip: 24; Typical Switch: CISCO 2950, 3500, 3750, 24-Port
1435346-5
Ports per Strip: 2; Typical Switch: CISCO 3500 Fiber Uplink Ports
1435818-1
Ports per Strip: 16; Typical Switch: CISCO GBIC, 16-Port Blade
1435820-1
Ports per Strip: 26; Typical Switch: CISCO 2950, 24-Port + 2 Uplink Ports
1435827-1
Ports per Strip: 16; Typical Switch: EXTREME Summit 48i
1435927-1
Ports per Strip: 24; Typical Switch: NORTEL BAYSTACK 450-24T, 24-Port
1435933-1
Ports per Strip: 24; Typical Switch: CISCO MT-RJ 6000, 24-Port Blade
1435937-1
Ports per Strip: 24; Typical Switch: NORTEL BAYSTACK 470-48T, 48-Port
1435939-1
Ports per Strip: 2; Typical Switch: Generic Fiber Uplink Ports
1435950-1
Ports per Strip: 12; Typical Switch: EXTREME Summit 1i & 5i and Alpine 3808
1435952-1
Ports per Strip: 2; Typical Switch: ALCATEL 6648 Fiber Uplink Ports
1479890-1
Ports per Strip: 48; Typical Switch: CISCO 6148, 48 ports
1499651-1
Ports per Strip: 48; Typical Switch: NORTEL BAYSTACK 5520
1499660-1
Ports per Strip: 24; Typical Switch: ALCATEL OmniSwitch OS6624, 24-Port
1777005-1
Ports per Strip: 24; Typical Switch: NORTEL PASSPORT 8648, 24-Port
1777014-1
Ports per Strip: 12; Typical Switch: Generic Stacked, 14 mm Spacing, 12-Port
1777019-1
Ports per Strip: 8; Typical Switch: HP Procurve J4111A
1933098-1
Ports per Strip: 24; Typical Switch: HP Procurve J8702A & 3500yl
1933899-1
318108AE 12/13 www.te.com/enterprise-asia
8. Managed Connectivity
Description
123
Managed Connectivity
Accessories
Cable Management Brackets and Bars
FEATURES
• Brackets and bars provide support for Scanning Module cables
or Patch Cords
• Front mount to monitored Patch Panels and switches
• Adjustable universal brackets for use at left or right panel edge
ORDERING INFORMATION
Description
Part Number
Scanning Module cable retainer bracket for CISCO 3500, 48 port switch
1435779-1
Universal Scanning Module cable bracket 40 mm, single-side-mount
1499659-1
Universal Scanning Module cable bracket 100 mm, single-side-mount
1499659-2
Universal Scanning Module cable bracket 448 mm, double-side-mount
1499659-3
1U Cable Management Bar Rack Mounting
1557548-1
Patch Cord management bar
1711344-1
1U Cable Management Bar Patch Panel Mounting
1933425-1
8. Managed Connectivity
124
www.te.com/enterprise-asia 12/13 318108AE
9. Optical LAN Solutions
Introduction........................................................................................................126
Rapid Fiber Distribution Hub (iFDH) .....................................................127
Rack Mount Fiber Distribution Hub (FDH)...........................................128
Splitter Modules & Fiber Distribution Terminal...................................129
Wall Boxes.......................................................................................................... 130
Fiber Panels and Connectivity....................................................................131
318108AE 12/13 www.te.com/enterprise-asia
125
Introduction
As optical fiber moves closer to end users, rapid changes are underway in both the data center and the
equipment closet. As a result, new installation and maintenance techniques are being employed within
enterprise applications. Passive Optical Network (PON) applications are now being deployed. Fiber is no
longer limited to just access equipment. Fiber connectivity to a single user is a reality.
TE Connectivity offers a complete, end-to-end PON infrastructure solution called Optical LAN
Solutions (OLS). From the data center to the desktop, our customers have tapped the experience and
innovation of TE to build their PON networks. TE’s suite of end-to-end connectivity solutions is truly
comprehensive. This ordering guide highlights the most commonly used components that feature fieldproven attributes that save time, money, and can help improve customer satisfaction.
The diagram below highlights a PON deployment using the TE OLS solution. Each number corresponds
to a specific innovative TE solution which is described in more detail in this ordering guide.
Router
OLT
Fiber Panel
FDH - Fiber Distribution Hub
Fiber Wall Plate
2
ONT
FDT
Fiber Distribution
Terminal
5
7
2
6
4
3
End-to-End Network Infrastructure
5 6
7
9. Optical LAN Solutions
d
Optical LAN Solution
4
3
1
1
1
2
Rapid Indoor Fiber
Distribution Hub (iFDH) with
"preconnectorized" stubs
3
Rapid Fiber Distribution
Terminal (FDT) with
"preconnectorized" stubs
4
UCP Rack Mount
Fiber Panels
2
Rapid Indoor Fiber
Distribution Hub (iFDH) with
"preconnectorized" stubs
3
Rapid Fiber Distribution
Terminal (FDT) with
"preconnectorized" stubs
4
RealFlex™ MDU Dop Cables
RealFlex™ MDU Dop Cables
5
Fiber Patch Cord
6
Ethernet Cable
7
Wall Plate
Fiber Splitter Box (FSB)
Video WDM
Optional Component Configurations
6
126
Ethernet Cable
7
Wall Plate
www.te.com/enterprise-asia 12/13 318108AE
Optical LAN Solution
Rapid Fiber Distribution Hub (iFDH)
Rapid Fiber Distribution Hub (iFDH)
TE‘s Rapid Fiber Distribution Hub organizes and administers
optical fiber cables and passive optical splitters for enterprise
PON applications. The enclosures support plug-and-play
termination with a cross-connect/interconnect interface that
makes installation, maintenance, and changes faster and
easier. The RapidReel™ feeder cable speeds up installation time
and conveniently stores slack inside the iFDH.
FEATURES
• Support plug-and-play termination
• Can be either wall or rack mounted
with the hardware provided
• Traditional swing-frame design allows superior rear access
• Includes RapidReel™ feeder cable
• Designed to meet NEMA-12 requirements
• UL 1863 Listed
2
Rapid Indoor FDH with Easy
Access to Built-in MPO Panel
ORDERING INFORMATION
72-Port
for up to 9
splitters
Feeder Cable Type
Distribution Type
100’
12-fiber plenum
288-Port
for up to 18
splitters
6 MPO adapters
24 MPO adapters
24-fiber plenum
432-Port
for up to 22
splitters
Feeder Stub Length
36 MPO adapters
Part Number
OLH-MK072J00M0MKCA
250’
OLH-MK072J00M0MKEA
500’
OLH-MK072J00M0MKBA
100’
OLH-MM288J00M0MKCB
250’
OLH-MM288J00M0MKEB
500’
OLH-MM288J00M0MKBB
100’
OLH-MN432J00M0MKCB
250’
OLH-MN432J00M0MKEB
500’
OLH-MN432J00M0MKBB
9. Optical LAN Solutions
Description
*Note: Splitters are purchased separately; ordering information on the following page.
318108AE 12/13 www.te.com/enterprise-asia
127
Optical LAN Solution
Rack Mount Fiber Distribution Hub (FDH)
Unloaded 1U RMG Series Rack Mount Patch Enclosures
FEATURES
• Suitable for Fiber Optic pre-terminated solution, field direct termination
and splice termination
• RMG adapter plates or MPO cassettes sold separately
• Heavy duty, smooth operating, slide mounting brackets
• Clear, removable top cover
• Flush mounting
• Holds 2 splice trays (sold separately)
• Fits standard TIA 19-inch racks
ORDERING INFORMATION
Compatible
Capacity
Racks
Adapter Plates
Cassettes
Part Number
19-inch
3
3
1-1657014-7
Unloaded 2 – 4U RMG Series Rack Mount Patch Enclosures
FEATURES
• Suitable for Fiber Optic pre-terminated solution, field
direct termination and splice termination
• RMG adapter plates or MPO cassettes sold separately
• Removable front and rear covers for easy access and installation
• Front and rear fiber/cable management rings
A
• Edge guard on front cable entries for cable assembly protection
• Forward, flush or recessed mounting
• Fits standard TIA 19” and 23” racks
• Standard Cable Enclosure includes cable strain relief
9. Optical LAN Solutions
• Enclosures shown loaded for reference only
B
ORDERING INFORMATION
Height
Racks
Adapter Plates
Cassettes
Figure
2U
19 or 23-inch
4
4
A
Part Number
559542-2
3U
19 or 23-inch
8
8
B
559614-2
4U
19 or 23-inch
12
12
C
559552-2
C
RMG Adapter Plates and Cassette
FEATURES
• Fit TE unloaded RMG Series Optical Fiber Enclosure
ORDERING INFORMATION
Description
Part Number
RMG Adapter Plates, 6 Duplex SC APC Ports (12 Fibers), SM
RMG MPO to SC Cassettes, 1 x MPO to 6 x SC APC Duplex, SM
128
www.te.com/enterprise-asia 12/13 318108AE
559596-3
1918447-1
Optical LAN Solution
Splitter Modules & Fiber Distribution Terminal
Mini Plug & Play Splitter Modules
TE‘s Mini Plug & Play Splitter Modules support centralized splitting architectures.
The modules are available in a wide range of split ratios and are used in TE‘s iFDH
OLH series cabinets. The rugged packaging is built for high performance, while the
true plug & play design reduces installation time.
FEATURES
• Bend-optimized fiber and ruggedized extreme temperature cabling
• Operating temperature range -55° to +85° C
• Superior loss performance at 1490 and 1550 wavelengths
• Easy to insert and remove without affecting adjacent splitters
• Allows pass-through of up to 2 fibers per splitter
• UL 1863 Listed
ORDERING INFORMATION
Description
Part Number
Optical Splitter Module
Angled SC Pigtails, used with iFDH, FSB,
Splitter Drawer and Splitter Panels
1 x 64 splitter
FPS-MPA1SJJ
1 x 32 splitter
FPS-MPA1AJJ
1 x 16 splitter
FPS-MPA1CJJ
1 x 8 splitter
Rack Mount Splitter Panel
FPS-MPA1JJJ
OPS-MPPRACKMT24
Cable Manager
OPS-MPPRACKMTCM
Rack Mount Splitter Drawer
OPS-MPPACCRMPNL
Rapid Fiber Distribution Terminal
9. Optical LAN Solutions
TE‘s Rapid Fiber Distribution Terminal (FDT) provides a compact, NEMA-12 rated solution for
connecting optical fiber cables within enterprise environments and serve as the distribution point
between the Rapid iFDH and the user area. It eliminates the need for splice cases and separate
cable assemblies by integrating the RapidReel cable payout system. Use of factory terminated
and tested MPO connectors instead of splicing provide a plug-and-play environment that reduces
labor costs and speeds project completion. The Rapid FDT provide a lockable consolidation
point and localized patch field, allowing for precise cable length customization in the field, while
reducing overall cable volume and simplifying routing from the FDH to the user area. The iFDT‘s
compact footprint enables it to be placed under raised floors or wall mounted.
FEATURES
• Built-in RapidReel technology allows for easy payoff of MPO stub
• Patented break-away spool flanges reduce slack storage
size to within the enclosures footprint
• Utilizes Reduced Bend Radius Fiber
• UL 1863 Listed
3
ORDERING INFORMATION
Description
Stub
12-fiber
Loose tube plenum cable
MPO
24-fiber
Loose tube plenum cable
Feeder Stub Length
Part Number
100’
OLR-SJ12J00D1002A
200’
OLR-SJ12J00D2002A
300’
OLR-SJ12J00D3002A
100’
OLR-SJ24J00D1002A
200’
OLR-SJ24J00D2002A
300’
OLR-SJ24J00D3002A
318108AE 12/13 www.te.com/enterprise-asia
Rapid FDT
(using slider adapter packs)
129
Optical LAN Solution
Wall Boxes
Wall Boxes
TE’s Fiber Splitter Boxes (FSB) are mini Fiber Distribution Hubs that can be
used for plug and play (PNP) or fusion splice applications.
When used as a plug and play box, they are ideal for uses such as lower
count floors or buildings, extra capacity requirements beyond the standard
Fiber Distribution Hub (FDH), and when localized splitting or physical path
redundancy (using a 2 x 32 split) is desired.
The same box can also be used to extend services beyond the primary building
to other smaller buildings with limited users on the campus. In this type of
application, the FSB is typically spliced to the OSP fiber cable connecting the
buildings and would offer the optical splitting required to provide PON services
to the second building.
FSB-32 Indoor Enclosure
These wall boxes provide a small footprint for splitting, terminating, and
splicing. FSBs accept standard plug and play splitters and can be easily added
after the wall box has been installed. FSBs accommodate 1 x 8, 1 x 16, 1 x 32,
and 2 x 32 splitters. Wall mounting provides significant space savings and the
unique swing frame design allows for easy access to the back section of the
wall box.
FEATURES AND BENEFITS
• Dual hinge design creates separation between rear
splitter section and front customer side access
• Splitters can be easily installed after wall box
installation allowing for separate purchase
• Provides up to 32 customer access ports per splitter
• Dual hinge provides small footprint on the wall while
maintaining excellent hand access to connectors
• Accepts standard PNP splitter modules (same as iFDH)
• UL 1863 Listed
9. Optical LAN Solutions
ORDERING INFORMATION
Description
FSB-32 Indoor Enclosure;
with SC/APC adapters,
32-fiber distribution
Optical Splitter Module
- Angled SC Pigtails
130
Part Number
No splitters, no splice trays
OSB-SBJ032000000
No splitters, with heat shrink splice trays
OSB-SBJ232000000
1 x 32 splitter installed, no splice trays
OSB-SBJ032A10000
1 x 32 splitter installed, with heat shrink splice trays
OSB-SBJ232A10000
2 x 32 splitter installed, no splice trays
OSB-SBJ032G10000
2 x 32 splitter installed, with heat shrink splice trays
OSB-SBJ232G10000
1 x 64 splitter
FPS-MPA1SJJ
1 x 32 splitter
FPS-MPA1AJJ
1 x 16 splitter
FPS-MPA1CJJ
1 x 8 splitter
FPS-MPA1JJJ
www.te.com/enterprise-asia 12/13 318108AE
Optical LAN Solution
Fiber Panels and Connectivity
SC Simplex Drop Cable
ORDERING INFORMATION
Description
Part Number
SC/APC-SC/APC Simplex Drop Cable G.657-A.2, yellow
Y-2160593-X
SC/APC-SC/UPC Simplex Drop Cable G.657-A.2, yellow
Y-2160594-X
Y- -X
Length
Y- -X Length
Y- -X
Length
Y- -X
Length
Y- -X
Length
Y- -X
Length
0- -1
1m
0- -5
5m
2- -5
25 m
4- -5
45 m
6- -5
65 m
8- -5
85 m
0- -2
2m
1- -0
10 m
3- -0
30 m
5- -0
50 m
7- -0
70 m
9- -0
90 m
0- -3
3m
1- -5
15 m
3- -5
35 m
5- -5
55 m
7- -5
75 m
9- -5
95 m
0 -4
4m
2- -0
20 m
4- -0
40 m
6- -0
60 m
8- -0
80 m
SC to MPO Quick-Fit cassettes or MPO to MPO modules
For SC and MPO fiber management please use our
MPOptimate Quick-Fit cassettes and modules
- for MPO to SC Quick-Fit cassettes please
see Chapter 1 - MPO/MPOptimate System
9. Optical LAN Solutions
- for MPO Coupler Quick-Fit modules please
see Chapter 1 - MPO/MPOptimate System
318108AE 12/13 www.te.com/enterprise-asia
131
132
www.te.com/enterprise-asia 12/13 318108AE
10. AMP CO System
AMP CO Ultra Panels......................................................................................134
AMP CO Ultra Outlets.................................................................................... 137
AMP CO Inserts..................................................................................................141
AMP CO Tools & Accessories......................................................................148
318108AE 12/13 www.te.com/enterprise-asia
133
AMP CO System
AMP CO Ultra Panels
AMP CO Ultra Quick-Fit 8 Port Patch Panel
FEATURES
• 19” 1U patch panel for 8 AMP CO Ultra Inserts
• Fast termination and easy assembly
• Shielded housing with patented automatic shielding clamp
• Straight cable exit plus management bar
• Kit includes 4 AMP CO Ultra Quick-Fit Kits, mounting material and grounding bolt
• Performance up to 2.0 GHz
ORDERING INFORMATION
Description
Color
Part Number
AMP CO Ultra Quick-Fit 8 Port Patch Panel
Light grey (RAL 7035)
2153112-1
Black (RAL 9005)
2153112-3
AMP CO Ultra Quick-Fit 16 Port Patch Panel
FEATURES
• 19” 2U patch panel for 16 AMP CO Ultra Inserts
• Fast termination and easy assembly
• Shielded housing with patented automatic shielding clamp
• Straight cable exit plus management bar
• Kit includes 8 AMP CO Ultra Quick-Fit Kits, mounting material and grounding bolt
• Performance up to 2.0 GHz
ORDERING INFORMATION
Description
Color
Part Number
AMP CO Ultra Quick-Fit 16 Port Patch Panel
Light Grey (RAL 7035)
2153113-1
Black (RAL 9005)
2153113-3
10. AMP CO System
134
www.te.com/enterprise-asia 12/13 318108AE
AMP CO System
AMP CO Ultra Panels
AMP CO Ultra 24 Port High Density Patch Panel
FEATURES
• 19” 2U patch panel for 24 AMP CO Ultra Inserts
• Fast termination and easy assembly
• Shielded housing with patented automatic shielding clamp
• Straight cable exit plus management bar
• Kit includes 24 die cast housings, 24 AMP CO Plus Edge
Connectors,
frames, mounting material and grounding bolt
• Performance up to 2.0 GHz
ORDERING INFORMATION
Description
Color
AMP CO Ultra 24 Port High Density Patch Panel
Light Grey (RAL 7035)
Part Number
1711686-1
Black (RAL 9005)
1711686-3
Foldable UCP Patch Panel
10. AMP CO System
For Foldable UCP Patch Panel, please see Chapter 4, page 45
318108AE 12/13 www.te.com/enterprise-asia
135
AMP CO System
AMP CO Ultra Panels
AMP CO Ultra Quick-Fit Kit
FEATURES
• Fits in UCP Patch Panel angled and flush mount
as well as consolidation point boxes
• Fast termination and easy assembly
• Shielded housing with patented automatic shielding clamp
• Kit includes 2 die-cast housings, 2 shielded edge
connectors and frame for labelling
• Performance up to 2.0 GHz
ORDERING INFORMATION
Description
Color
AMP CO Ultra Quick-Fit Kit
Black (RAL 9005)
Part Number
2153014-1
CP Box for Quick-Fit Cassettes & Modules
FEATURES
• Consolidation point box ready for 1 AMP CO Ultra Quick-Fit Kits
• Robust sheet metal construction
• Two separate zones; installation zone and user zone
• Hinged cover with knurled screw
• Dust protection for the full connection
• Grounding bolt included
ORDERING INFORMATION
Description
Color
Part Number
CP Box for Quick-Fit Cassettes & Modules
Black (RAL 9005)
1-1671414-1
AMP CO Ultra Distribution Box
10. AMP CO System
FEATURES
• 1U distribution box for surface mount or raised floor use for
8 AMP CO Ultra Inserts
• Robust sheet metal construction
• Fast termination and easy assembly
• Shielded housing with patented automatic shielding clamp
• Kit includes 4 AMP CO Ultra Quick-Fit Kits, mounting material and grounding bolt
• Performance up to 2.0 GHz
ORDERING INFORMATION
Description
Color
AMP CO Ultra Distribution Box
Black (RAL 9005)
136
Part Number
2153173-3
www.te.com/enterprise-asia 12/13 318108AE
AMP CO System
AMP CO Ultra Outlets
AMP CO Ultra Installation Kit DIN 50x50
FEATURES
• Fast termination and easy assembly
• Shielded installation kit flush mount
• DIN faceplate 50 x 50 mm
• Compatible with standard and designer frame series
• Metal frame ready for different footprint
or fixation configurations
• Shielded edge connector for AWG 22-24 twisted pair cables
• Shielded housing with tangible screen termination
• Strain relief by cable tie
• Top, left or right cable entry
• 2.0 GHz performance
ORDERING INFORMATION
Description
Color
AMP CO Ultra Installation Kit DIN 50x50
Almond (RAL 1013)
1711655-1
Black (RAL 9005)
1711655-3
Pure White (RAL 9010)
Part Number
2-1711655-1
AMP CO Ultra Installation Kits DIN 68x68
FEATURES
• Fast termination and easy assembly
• Shielded installation kit flush mount
• Straight or angled versions
• DIN faceplate 68 x 68 mm
• Metal frame ready for different footprint
or fixation configurations
• Shielded edge connector for AWG
2-24 twisted pair cables
• Shielded housing with tangible screen termination
10. AMP CO System
• Strain relief by cable tie
• Top, left or right cable entry
• 2.0 GHz performance
ORDERING INFORMATION
Description
Color
AMP CO Ultra Installation Kit DIN 68x68
Almond (RAL 1013)
AMP CO Ultra Installation Kit DIN 68x68
Pure White (RAL 90100
AMP CO Ultra Installation Kit DIN 68x68 Top
Almond (RAL 1013)
AMP CO Ultra Installation Kit DIN 68x68 Top
Pure White (RAL 9010)
AMP CO Ultra Installation Kit DIN 68x68 Angled
Almond (RAL 1013)
AMP CO Ultra Installation Kit DIN 68x68 Angled
Pure White (RAL 9010)
Part Number
1711856-1
2-1711856-1
1711870-1
2-1711870-1
1711875-1
2-1711875-1
318108AE 12/13 www.te.com/enterprise-asia
137
AMP CO System
AMP CO Ultra Outlets
AMP CO Ultra Installation Kit DIN Floor Box
FEATURES
• Fast termination and easy assembly
• Shielded installation kit floor box
• Shielded edge connector for AWG 22-24 twisted pair cables
• Shielded housing with tangible screen termination
• Strain relief by cable tie
• Bottom cable entry
• 2.0 GHz performance
ORDERING INFORMATION
Description
Color
AMP CO Ultra Installation Kit DIN 50x50 Floor Box
Almond (RAL 1013)
Part Number
1711876-1
AMP CO Ultra Installation Kit DIN 70x58 Floor Box
Almond (RAL 1013)
1711855-1
AMP CO Ultra Installation Kit Swiss “EDIZIOdue Compatible”
FEATURES • Fast termination and easy assembly
• Shielded installation kit flush mount and surface mount
• Faceplate applicable to “EDIZIOdues Compatible” systems
• Shielded edge connector for AWG 22-24 twisted pair cables
• Shielded housing with tangible screen termination
• Strain relief by cable tie
• Top, left or right cable entry
• 2.0 GHz performance
ORDERING INFORMATION
10. AMP CO System
Description
Color
AMP CO Ultra Installation Kit Swiss EDIZIOdue Compatible AP
Pure White (RAL 9010)
1711869-1
AMP CO Ultra Installation Kit Swiss EDIZIOdue Compatible UP
Pure White (RAL 9010)
1711859-1
AMP CO Ultra Installation Kit Swiss EDIZIOdue Compatible UP
Black (RAL 9005)
1711859-2
AMP CO Ultra Installation Kit Swiss EDIZIOdue Compatible KNL
Light Gray
1711858-1
AMP CO Ultra Installation Kit Swiss EDIZIOdue Compatible KNL
Dark Gray
1711858-2
AMP CO Ultra Installation Kit Swiss EDIZIOdue Compatible KNL
Black (RAL 9005)
1711858-3
AMP CO Ultra Installation Kit Swiss EDIZIOdue Compatible KNL
Pure White (RAL 9010)
1711858-4
138
www.te.com/enterprise-asia 12/13 318108AE
Part Number
AMP CO System
AMP CO Ultra Outlets
AMP CO Ultra Installation Kit Swiss “Standard”
FEATURES
• Fast termination and easy assembly
• Shielded installation kit flush mount and surface mount
• Faceplate applicable to “Standard” systems
• Shielded edge connector for AWG 22-24 twisted pair cables
• Shielded housing with tangible screen termination
• Strain relief by cable tie
• Top, left or right cable entry
• 2.0 GHz performance
ORDERING INFORMATION
Description
Color
AMP CO Ultra Installation Kit Swiss UP
Pure White (RAL 9010)
Part Number
1711861-1
AMP CO Ultra Installation Kit Swiss AP
Pure White (RAL 9010)
1711862-1
AMP CO Ultra Installation Kit Swiss KNL
Pure White (RAL 9010)
1711864-1
AMP CO Ultra Installation Kit Swiss “FLF”
FEATURES
• Fast termination and easy assembly
• Shielded installation kit flush mount and surface mount
• Faceplate applicable to “FLF” systems
• Shielded edge connector for AWG 22-24 twisted pair cables
• Shielded housing with tangible screen termination
• Top, left or right cable entry (90º) and rear cable exit (180º)
• 2.0 GHz performance
ORDERING INFORMATION
Color
AMP CO Ultra Installation Kit Swiss FLF, Cable exit 90º
Pure White (RAL 9010)
1711865-1
AMP CO Ultra Installation Kit Swiss FLF AP, Cable exit 90º
Pure White (RAL 9010)
1711866-1
AMP CO Ultra Installation Kit Swiss FLF, Cable exit 180º
Pure White (RAL 9010)
2153074-1
AMP CO Ultra Installation Kit Swiss FLF AP, Cable exit 180º
Pure White (RAL 9010)
2153075-1
318108AE 12/13 www.te.com/enterprise-asia
Part Number
10. AMP CO System
Description
139
AMP CO System
AMP CO Ultra Outlets
AMP CO Ultra Installation Kit 45 x 45
FEATURES
• Fast termination and easy assembly
• Shielded installation kit flush mount
• Faceplate 45 x 45 mm
• Shielded edge connector for AWG 22-24 twisted pair cables
• Shielded housing with tangible screen termination
• Strain relief by cable tie
• Top, left or right cable entry
• 2.0 GHz performance
ORDERING INFORMATION
Description
Color
Part Number
AMP CO Ultra Installation Kit 45x45
Almond (RAL 1013)
1711860-1
AMP CO Ultra Installation Kit 45x45
Pure White (RAL 9010)
1711860-2
Adaptor Frame to 50 x 50 mm
Almond (RAL 1013)
1379156-1
10. AMP CO System
140
www.te.com/enterprise-asia 12/13 318108AE
AMP CO System
AMP CO Inserts
AMP CO Plus Category 7A AMP-TWIST 7AS Style Insert
FEATURES
• Exchangeable system insert for 1 x ISO Category 7A (acc. IEC 61076-3-104)
• Class FA, supports 1 GHz bandwidth
• Application: All services incl. 10 Gigabit Ethernet (10GBASE-T)
Pin out: EIA/TIA 568A; 8 pins, shielded
ORDERING INFORMATION
Description
Color
Part Number
Insert Cat. 7A AMP-TWIST 7AS Style
Almond (RAL 1013)
1711409-1
Black (RAL 9005)
1711409-3
Pure White (RAL 9010)
1711409-5
AMP CO Plus Category 7A ARJ-45 Insert
FEATURES
• Exchangeable system insert for 1 x ISO Category 7A (compatible with IEC 60603-7-7)
• Class FA, supports 1 GHz bandwidth
• Application: All Ethernet services incl. 10 Gigabit Ethernet (10GBASE-T)
Pin out: EIA/TIA 568A; 8 pins, shielded
ORDERING INFORMATION
Description
Color
Insert Cat. 7A ARJ-45
Almond (RAL 1013)
Part Number
1711609-1
Black (RAL 9005)
1711609-3
Pure White (RAL 9010)
1711609-5
AMP CO Plus Category 7 Dual RJ-45 Insert for ATM
10. AMP CO System
FEATURES
• Exchangeable system insert 2 x RJ-45
• Category 7 / Class F
• Application: 2 x ATM 622 MBit/s
Pin out: 12.78 + 12.78; 2 x 4 pins, shielded
ORDERING INFORMATION
Description
Color
Part Number
Insert 2 x RJ-45 Cat. 7
Almond (RAL 1013)
336556-1
Black (RAL 9005)
336556-3
Pure White (RAL 9010)
336556-5
318108AE 12/13 www.te.com/enterprise-asia
141
AMP CO System
AMP CO Inserts
AMP CO Plus Broadband Inserts for “Triple Play”
FEATURES
• Exchangeable system insert with F-series connector and 2 x RJ-45
• Application: 1 x CATV + 1 x Fast Ethernet (100BASE-TX) + 1x ISDN
Pin out: Balun 75Ω + 12.36 + 45; shielded
ORDERING INFORMATION
Description
Color
Insert F-Series + 2 x RJ-45
Almond (RAL 1013)
Part Number
1711336-1
Black (RAL 9005)
1711336-3
Pure White (RAL 9010)
1711336-5
AMP CO Plus Splitter Insert for Gigabit Ethernet and ISDN
FEATURES
• Exchangeable system insert 2 x RJ-45
• Application: 1 x Gigabit Ethernet (1000BASE-T) + 1x ISDN
• ITU I.430 services
• ISDN port is a 4 wire s-bus basic rate interface (BRI) including
power feeding
• Two splitters required for system operation
Pin out: EIA/TIA 568 A: 8 pins, shielded
ORDERING INFORMATION
Description
Color
Insert 2 x RJ-45 mixed
Almond (RAL 1013)
Part Number
1591721-1
Black (RAL 9005)
1591721-3
Pure White (RAL 9010)
1591721-5
AMP CO Plus Category 6A RJ-45 Insert for 10 Gigabit Ethernet
10. AMP CO System
FEATURES
• Exchangeable system insert 1 x RJ-45
• Category 6A / Class EA
• Application: All Ethernet services incl. 10 Gigabit
Ethernet (10GBASE-T) or ATM 1.2 GBit/s
Pin out: EIA/TIA 568A; 8 pins, shielded
ORDERING INFORMATION
Description
Color
Insert 1 x RJ-45 Cat. 6A
Almond (RAL 1013)
1711796-1
Black (RAL 9005)
1711796-3
Pure White (RAL 9010)
1711796-5
142
Part Number
www.te.com/enterprise-asia 12/13 318108AE
AMP CO System
AMP CO Inserts
AMP CO Plus Category 6A Dual RJ-45 Insert for Fast Ethernet
FEATURES
• Exchangeable system insert 2 x RJ-45
• Category 6A / Class EA
• Application: 2 x Fast Ethernet (100BASE-TX)
Pin out: 12.36 + 12.36; 2 x 4 pins, shielded
ORDERING INFORMATION
Description
Color
Part Number
Insert 2 x RJ-45 Cat. 6A Ethernet
Almond (RAL 1013)
1711801-1
Black (RAL 9005)
1711801-3
Pure White (RAL 9010)
1711801-5
AMP CO Plus Category 6A Dual RJ-45 Insert for Fast Ethernet + Voice/Data
FEATURES
• Exchangeable system insert 2 x RJ-45
• Category 6A / Class EA
• Application: 1 x Fast Ethernet (100BASE-TX) + 1 x ISDN, xDSL or Token Ring
Pin out: 36.45 + 12.36; 2 x 4 pins, shielded
ORDERING INFORMATION
Description
Color
Part Number
Insert 2 x RJ-45 Cat. 6A mixed
Almond (RAL 1013)
1711804-1
Black (RAL 9005)
1711804-3
Pure White (RAL 9010)
1711804-5
AMP CO Plus Category 6A Dual RJ-45 Insert for Voice/Data
10. AMP CO System
FEATURES
• Exchangeable system insert 2 x RJ-45
• Category 6A / Class EA
• Application: 2 x ISDN, xDSL or Token Ring
Pin out: 36.45 + 36.45; 2 x 4 pins, shielded
ORDERING INFORMATION
Description
Color
Part Number
Insert 2 x RJ-45 Cat. 6A ISDN
Almond (RAL 1013)
1711807-1
Black (RAL 9005)
1711807-3
Pure White (RAL 9010)
1711807-5
318108AE 12/13 www.te.com/enterprise-asia
143
AMP CO System
AMP CO Inserts
AMP CO Plus Category 6 RJ-45 Insert for 1 Gigabit Ethernet
FEATURES
• Exchangeable system insert 1 x RJ-45
• Category 6 / Class E
• Application: 1x Gigabit Ethernet (1000BASE-T),
1 x Fast Ethernet (100BASE-TX) or ATM 1.2 GBit/s
Pin out: EIA/TIA 568A; 8 pins, shielded
ORDERING INFORMATION
Description
Color
Insert 1 x RJ-45 Cat. 6
Almond (RAL 1013)
Part Number
336548-1
Black (RAL 9005)
336548-3
Pure White (RAL 9010)
336548-5
AMP CO Plus Category 5e RJ-45 Insert for Gigabit Ethernet
FEATURES
• Exchangeable system insert 1 x RJ-45
• Category 5e / Class D
• Application: 1x Gigabit Ethernet (1000BASE-T)
or 1 x Fast Ethernet (100BASE -TX)
Pin out: EIA/TIA 568 A; 8 pins, shielded
ORDERING INFORMATION
Description
Color
Part Number
Insert 1 x RJ-45 Cat. 5e
Almond (RAL 1013)
284584-1
Black (RAL 9005)
284584-3
Pure White (RAL 9010)
284584-5
AMP CO Plus Category 5e Dual RJ-45 Insert for Fast Ethernet
10. AMP CO System
FEATURES
• Exchangeable system insert 2 x RJ-45
• Category 5e / Class D
• Application: 2 x Fast Ethernet (100 Base-TX)
Pin out: 12.36 + 12.36; 2 x 4 pins, shielded
ORDERING INFORMATION
Description
Color
Insert 2 x RJ-45 Cat. 5e Ethernet
Almond (RAL 1013)
183636-1
Black (RAL 9005)
183636-3
Pure White (RAL 9010)
183636-5
144
Part Number
www.te.com/enterprise-asia 12/13 318108AE
AMP CO System
AMP CO Inserts
AMP CO Plus Category 5e Dual RJ-45 Insert for Fast Ethernet + Voice/Data
FEATURES
• Exchangeable system insert 2 x RJ-45
• Category 5e / Class D
• Application: 1 x Fast Ethernet (100BASE-TX) + 1 x ISDN, xDSL or Token Ring
Pin out: 36.45 + 12.36; 2 x 4 pins, shielded
ORDERING INFORMATION
Description
Color
Part Number
Insert 2 x RJ-45 Cat. 5e mixed
Almond (RAL 1013)
183641-1
Black (RAL 9005)
183641-3
Pure White (RAL 9010)
183641-5
AMP CO Plus Category 5e Dual RJ-45 Insert for Voice/Data
FEATURES
• Exchangeable system insert 2 x RJ-45
• Category 5e / Class D
• Application: 2 x ISDN, xDSL or Token Ring
Pin out: 36.45 + 36.45; 2 x 4 pins, shielded
ORDERING INFORMATION
Description
Color
Part Number
Insert 2 x RJ-45 Cat. 5e ISDN
Almond (RAL 1013)
183635-1
Black (RAL 9005)
183635-3
Pure White (RAL 9010)
183635-5
AMP CO Plus Dual Patch Panel Insert PoE Power Conversion
10. AMP CO System
FEATURES
• Exchangeable system insert 2 x RJ-45
• Converts IEEE 802.3af mode B input to mode A output
• Uses Power Mux/Demux Technology
• For use with midspan units providing
power over unused pairs
• Application: 2 x PoE (input mode independent),
e.g. VoIP, over a 4 pair cable (sheath sharing)
ORDERING INFORMATION
Description
Color
Insert 2 x PoE Power Conversion
Almond (RAL 1013)
Part Number
1711125-1
Black (RAL 9005)
1711125-3
Pure White (RAL 9010)
1711125-5
318108AE 12/13 www.te.com/enterprise-asia
145
AMP CO System
AMP CO Inserts
AMP CO Plus Dual Insert PoE Mode A
FEATURES
• Exchangeable system insert 2 x RJ-45
• 2 x PoE IEEE 802.3af Mode A
• For use in outlet or with phantom
power midspan units
• Application: 2 x PoE, e.g. VoIP, over
a 4 pair cable (sheath sharing)
Pin out: 12.36 + 12.36; 2 x 4 pins; shielded
ORDERING INFORMATION
Description
Color
Part Number
Insert 2 x PoE Mode A
Almond (RAL 1013)
1711135-1
Black (RAL 9005)
1711135-3
Pure White (RAL 9010)
1711135-5
AMP CO Plus 3-Port Insert Standard Phones
FEATURES
• Exchangeable system insert 3 x RJ-45
• 1 x Category 6 / Class E + 2 x Category 3 / Class C
• Application:
1 x Fast Ethernet (100BASE-TX) + 2 x Phones (2 wire use)
Pin out: 12.36 + 45 + 45; 1 x 4 pins shielded and 2 x 2 pins unshielded
ORDERING INFORMATION
Description
Color
Part Number
Insert 3 x RJ-45 for Standard phone
Almond (RAL 1013)
1711100-1
Black (RAL 9005)
1711100-3
Pure White (RAL 9010)
1711100-5
10. AMP CO System
AMP CO Plus 3-Port Insert Shunt Phones
FEATURES
• Exchangeable system insert 3 x RJ-45
• 1 x Category 6 / Class E + 2 x Category 3 / Class C
• Application: 1 x Fast Ethernet (100BASETX) + 2 x Phones (parallel use)
Pin out: 12.36 + 36.45 + 36.45; 1 x 4 pins shielded and 2 x 4 pins
unshielded
ORDERING INFORMATION
Description
Color
Insert 3 x RJ-45 for Shunt phone
Almond (RAL 1013)
1711450-1
Black (RAL 9005)
1711450-3
Pure White (RAL 9010)
1711450-5
146
Part Number
www.te.com/enterprise-asia 12/13 318108AE
AMP CO System
AMP CO Inserts
AMP CO Plus 4 Pair Sub-D 9pos Insert
FEATURES
• Exchangeable system insert 1 x Sub-D 9pos
• Includes M3 nuts for locking
ORDERING INFORMATION
Description
Color
Insert Sub-D 9pos
Almond (RAL 1013)
Part Number
183553-1
AMP CO Inserts for Voice Applications
FEATURES
• Exchangeable system insert 2 x or 4 x RJ-11
or RJ-45
• 2 x or 4 x Category 3 / Class C
• Application: ISDN, So or UpN
ORDERING INFORMATION
Description
Shielded
Terminated
Insert 2 x RJ-45; Use at: outlet/panel; Note: French version
Yes
No
Part Number
183578-1
Insert 2 x RJ11; Use at: outlet; Note: panel side 284584-X
No
No
555614-1
Insert 4 x RJ-45; Use at: outlet/panel; Note: French version
No
No
1644016-X
Insert 4 x RJ-45; Use at: outlet/panel; Note: panel + outlet
No
No
1711000-X
Insert 4 x RJ-45; Use at: outlet; Note: panel side 183635-X
No
100Ω
1711001-X
Insert 2 x RJ-45 parallel; Use at: outlet; Note: panel side 284584-X
No
No
1711339-1
-X
Color
-1
Almond
(RAL 1013)
-3
Black
(RAL 9005)
-5
Pure White
(RAL 9010)
AMP CO Plus Blank Insert
10. AMP CO System
FEATURES
• Blank insert
• Dust protection for unused ports
ORDERING INFORMATION
Description
Color
Blank Insert
Almond (RAL 1013)
Part Number
555644-1
Black (RAL 9005)
555644-3
Grey (RAL 7035)
555644-5
Pure White (RAL 9010)
555644-9
318108AE 12/13 www.te.com/enterprise-asia
147
AMP CO System
AMP CO Tools & Accessories
AMP CO Ultra Pistol-Grip Tool
FEATURES
• Pistol grip tool for fast and easy termination of AMP CO Ultra modules
• Ensures repeatable high termination quality
• Considerable reduction of termination time
• Including adapter pieces for termination of
AMP CO Ultra modules
• AMP CO Ultra Tool Adapters and Blade
are also available as spare parts
ORDERING INFORMATION
Description
Part Number
AMP CO Ultra Pistol-Grip Tool
1711500-1
AMP CO Ultra Tool Adapter for straight cable exit; Colour: grey
1711784-1
AMP CO Ultra Tool Adapter for top-left-right cable exit; Colour: black
1711784-2
AMP CO Ultra Tool Blade
2153117-1
AMP CO Plus Edge Connector
FEATURES
• Shielded edge connector for AWG 22-24 twisted pair cables
• 2.0 GHz performance
• 110C compatible IDC block
• Universal color code
• Fully shielded
ORDERING INFORMATION
Description
AMP CO Plus Edge Connector
Quantity
Part Number
100 pieces
336455-1
8 pieces
336455-2
10 pieces
336455-3
10. AMP CO System
Printer Labels for AMP CO Installation Kits
FEATURES
• Self-adhesive A4 sheets with printer labels for AMP CO Installation Kits
• Uses standard MS Excel sheet
ORDERING INFORMATION
Description
Part Number
Labels (6 x 32 mm, 170 pcs per sheet); Packaging 10 sheets
148
969704-1
www.te.com/enterprise-asia 12/13 318108AE
11. Fiber Optic Cabling
System Cables....................................................................................................... 150
Patch Panels........................................................................................................... 164
Accessories for Patch Panels...........................................................................168
Quick-Fit Modules................................................................................................ 169
Wall Mount Patch Panels.................................................................................. 170
RMG Modules...........................................................................................................171
Pre-assembled LC & SC Trunks.......................................................................173
Patch Cords and Pigtails....................................................................................175
Adaptors...................................................................................................................179
LightCrimp and LightCrimp Plus.................................................................. 180
Epoxy Connectors............................................................................................... 184
Splicing Products..................................................................................................187
Fiber Optic Tools....................................................................................................191
Fiber Cleaning and Inspection........................................................................198
318108AE 12/13 www.te.com/enterprise-asia
149
Fiber Optic Cabling
System Cables
Technical Data
MULTIMODE FIBERS
ISO/IEC 11801 and
EN 50173
Overfill Bandwidth
(MHz x km)
Max. Link Length for 1 GBit/s
(m)
Max. Link Length for 10 GBit/s
(m)
Fiber Attenuation
(dB/km)
850 nm
1300 nm
850 nm
(1000Base-SX)
1300 nm
(1000BaseLX)
850 nm
(10GBase-SR)
(10GBase-SW)
1300 nm
(10GBase-LX4)
850 nm
1300 nm
OM1
62,5 μm
≥ 200
≥ 600
275
550*
33
360*
≤ 3.5
≤ 1.0
OM2
50 μm
≥ 500
≥ 500
550
550*
83
300*
≤ 3.5
≤ 1.0
OM3 (XG)
50 μm
≥ 1500
≥ 500
1000
600
300
300
≤ 2.4
≤ 0.6
OM4
50 μm
≥ 3500
≥ 500
1040
600
550
300
≤ 2.4
≤ 0.6
OM4+
50 μm
≥ 3500
≥ 500
1200**
600
600**
300
≤ 2.4
≤ 0.6
* Mode Conditioning Patchcords required
** Preliminary reach, under investigation
SINGLEMODE FIBERS
ISO/IEC 11801 and EN
50173
OS2 (ITU-T G.652D
& G.657A2)
Chromatic Dispersion
(ps/nm x km)
1310 nm
1550 nm
≤ 3.5
≤ 18.0
9 μm
Cut-off
Wavelength,
cabled
(nm)
Point Discontinuity
(dB)
≤ 1260
≤ 0.1
Fiber Attenuation (dB/km)
1310 nm
1380–1386 nm
1550 nm
≤ 0.40
≤ 0.40
≤ 0.30
11. Fiber Optic Cabling
GEOMETRICAL FIBER PROPERTIES
Fiber Type
Core/Mode-field (µm)
Cladding (µm)
Coating (µm)
62.5 ± 3
125 ± 2
245 ± 10
OM1
OM2, OM3, OM4
50 ± 3
125 ± 2
245 ± 10
OS2
9 ± 0.6
125 ± 0.7
242 ± 8
OM4+
50 ± 2.5
125 ± 1.0
242 ± 5
FIBER MACRO-BENDING LOSS
Fiber Type
OM3, OM4, OM4+
OS2
Bend Radius(mm)
Number of Turns
Loss @850nm
Loss @1300nm
7.5
2
≤ 0.2dB
≤ 0.5dB
15
2
≤ 0.1dB
≤ 0.3dB
Loss @1550nm
Loss @1625nm
15
10
≤ 0.03dB
≤ 0.1dB
10
1
≤ 0.1dB
≤ 0.2dB
7.5
1
≤ 0.5dB
≤1.0dB
OPTICAL CABLE SPECIFICATIONS
Maximum Attenuation (dB/km)
Loose Tube
Tight Buffered
Multimode
850 nm
1300 nm
850 nm
1300 nm
OM1, OM2
3.5
1.0
3.5
1.0
OM3, OM4, OM4+
3.5
1.5
3.5
1.5
1310 nm
1550 nm
1310 nm
1550 nm
9/125
0.5
0.45
0.5
0.45
150
www.te.com/enterprise-asia 12/13 318108AE
Singlemode
Fiber Optic Cabling
System Cables
Fiber Cable Performance
OPTICAL FIBER CABLE TEMPERATURE RANGES
Riser
Zip Twin
(Tight Buffered) Cables
Storage
-10°C to +70°C
Operating
-10°C to +70°C
Installation
Indoor/Outdoor
(Loose Tube) Cables
Outdoor
(Loose Tube) Cables
-5°C to +70°C
Storage
-40°C to +70°C
-20°C to +70°C
Operating
-20°C to +70°C
-10°C to +70°C
Installation
-10°C to +60°C
-5°C to +50°C
Storage
-40°C to +70°C
Operating
-20°C to +70°C
Installation
-10°C to +60°C
Dielectric/Armored
Figure 8
Storage
-40°C to +70°C
-40°C to +70°C
Operating
-20°C to +70°C
-20°C to +70°C
Installation
-10°C to +60°C
-10°C to +60°C
11. Fiber Optic Cabling
Indoor
(Tight Buffered) Cables
LSZH
318108AE 12/13 www.te.com/enterprise-asia
151
DuaLAN
Fiber Optic Cabling
System Cables
Fiber
Tight
Buffering (900m)
Aramid Strength
Members
Horizontal, 2-4 Fiber (OFNR, PVC)
Outer Jacket
FEATURES:
• Suitable for direct termination with epoxy/
polish, LightCrimp and LightCrimp PLUS
Fiber
Tight
Buffering (900µm)
Aramid Strength
Members
2-Fiber
• Aramid yarn reinforcement
QuadLAN
Outer Jacket
• UL and cUL listed OFNR (Riser)
Fiber
Tight
Buffering (900µm)
Aramid Strength
Members
Outer Jacket
4-Fiber
-X
Fiber
Count
Unit Count
Unit
(Fibers/Unit)
Fiber
Type
UL/
NEC
Ratings
Jacket
Color
Part
Number
Weight kg/km
(ib/kft)
Singlemode
Riser
Yellow
X-1859416-4
17 (11)
Riser
Orange
X-1859416-2
17 (11)
Riser
Aqua
X-1859416-3
17 (11)
Riser
Aqua
X-1859416-5
17 (11)
Riser
Orange
X-1859416-1
17 (11)
Riser
Aqua
X-1859416-6
17 (11)
Riser
Yellow
X-1859417-4
19 (13)
Riser
Orange
X-1859417-2
19 (13)
Riser
Aqua
X-1859417-3
19 (13)
Riser
Aqua
X-1859417-5
19 (13)
Riser
Orange
X-1859417-1
19 (13)
Riser
Aqua
X-1859417-6
19 (13)
Diameter
mm (in)
Tensile Load N (lbf)
Reel Size
1-
1 Kilometer
2-
2 Kilometer
Bending Radius mm (in)
Installation
Long
Term
Installation
Long Term
4.8 (0.19)
660 (150)
198 (45)
96 (3.8)
48 (1.9)
4.8 (0.19)
660 (150)
198 (45)
96 (3.8)
48 (1.9)
2-Fiber (Dual)
Multimode
50/125 μm
1(2)
Multimode
11. Fiber Optic Cabling
50/125 μm OM3
Multimode
2
50/125 μm OM4
Multimode
62.5/125 μm
Multimode
50/125 μm
OM4+
4-Fiber (Quad)
Singlemode
Multimode
50/125 μm
1(4)
4
Multimode
50/125 μm OM3
Multimode
50/125 μm OM4
Multimode
62.5/125 μm
Multimode
50/125 μm
OM4+
152
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
System Cables
Indoor Distribution, 6-24 Fiber (OFNR, PVC)
FEATURES:
• Suitable for horizontal and in-building backbone cabling
and for direct termination with epoxy/polish, LightCrimp,
and LightCrimp PLUS
Horizontal Distribution
• Strippable 900 μm tight buffer coating allows for easy
connectorization
Fibers
• TIA color-coded fibers for easy identification
Tight Buffering (900µm)
• UL and cUL listed OFNR (Riser)
Strength Members
• Outer Jacket Color:
Outer Jacket
• Singlemode: Yellow
• 50/125 and 62.5/125μm: Orange
Fiber
6
8
12
24
Unit Count Unit
(Fibers/Unit)
1 (6)
1 (8)
1 (12)
1 (24)
X-
Reel size
1-
1 Kilometer
2-
2 Kilometer
Fiber Type
UL/NEC Ratings
Part Number
Singlemode
Riser
X-1859418-4
Multimode 50/125 μm
Riser
X-1859418-2
Multimode 50/125 μm OM3
Riser
X-1859418-3
Multimode 50/125 μm OM4
Riser
X-1859418-5
Multimode 62.5/125 μm
Riser
X-1859418-1
Multimode 50/125 μm OM4+
Riser
X-1859418-6
Singlemode
Riser
X-1859419-4
Multimode 50/125 μm
Riser
X-1859419-2
Multimode 50/125 μm OM3
Riser
X-1859419-3
Multimode 50/125 μm OM4
Riser
X-1859419-5
Multimode 62.5/125 μm
Riser
X-1859419-1
Multimode 50/125 μm OM4+
Riser
X-1859419-6
Singlemode
Riser
X-1859420-4
Multimode 50/125 μm
Riser
X-1859420-2
Multimode 50/125 μm OM3
Riser
X-1859420-3
Multimode 50/125 μm OM4
Riser
X-1859420-5
Multimode 62.5/125 μm
Riser
X-1859420-1
Multimode 50/125 μm OM4+
Riser
X-1859420-6
Singlemode
Riser
X-1859421-4
Multimode 50/125 μm
Riser
X-1859421-2
Multimode 50/125 μm OM3
Riser
X-1859421-3
Multimode 50/125 μm OM4
Riser
X-1859421-5
Multimode 62.5/125 μm
Riser
X-1859421-1
Multimode 50/125 μm OM4+
Riser
X-1859421-6
318108AE 12/13 www.te.com/enterprise-asia
153
11. Fiber Optic Cabling
Distribution Cables
• XG 50/125 μm: Aqua (OM3, OM4, OM4+)
Fiber Optic Cabling
System Cables
Indoor Distribution, 36-72 Fiber (OFNR, PVC)
FEATURES:
• Suitable for horizontal and in-building backbone cabling and for direct
termination with epoxy/polish, LightCrimp and LightCrimp PLUS
• Strippable 900 μm tight buffer coating allows for easy connectorization
• TIA color-coded fibers for easy identification
Backbone Distribution
• UL and cUL listed OFNR (Riser)
• Outer Jacket Color:
Dielectric Central
Dialectric
Central Strength Member
Strength Member
Fibers
Fibers
- Singlemode: Yellow
- 50/125 and 62.5/125 μm Orange
- XG 50/125 μm Aqua (OM3, OM4, OM4+)
Tight
Buffering
(900μm)
Tight Buffering
(900µm)
Strength
Members
Strength Members
Protective
Jacket
Protective Jacket
Binder
Binder
Outer
Jacket
Outer Jacket
Fiber Count
Unit Count Unit (Fibers/Unit)
Fiber Type
UL/NEC Ratings
Part Number
Singlemode
Riser
X-1859422-4
Multimode
Riser
X-1859422-2
Riser
X-1859422-3
Riser
X-1859422-5
Riser
X-1859422-1
Riser
X-1859422-6
Singlemode
Riser
X-1859423-4
Multimode
Riser
X-1859423-2
Riser
X-1859423-3
Riser
X-1859423-5
Riser
X-1859423-1
Riser
X-1859423-6
Singlemode
Riser
X-1859424-4
Multimode
Riser
X-1859424-2
Riser
X-1859424-3
Riser
X-1859424-5
Riser
X-1859424-1
Riser
X-1859424-6
50/125 μm
Multimode
36
6 (6)
11. Fiber Optic Cabling
50/125 μm OM3
Multimode
50/125 μm OM4
Multimode
62.5/125 μm
Multimode
50/125 μm OM4+
50/125 μm
Multimode
50/125 μm OM3
48
4 (12)
Multimode
50/125 μm OM4
Multimode
62.5/125 μm
Multimode
50/125 μm OM4+
50/125 μm
Multimode
50/125 μm OM3
72
6 (12)
Multimode
50/125 μm OM4
Multimode
62.5/125 μm
Multimode
50/125 μm OM4+
154
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
System Cables
MECHANICAL SPECIFICATIONS
Fiber Count
Flame
O.D.
Sub Unit O.D.
Minimum Bend Radius
Normal Weight
Rating Tensile Load
(Units x
Fibers/Unit)
Rating
mm(in)
mm (in)
Install
mm (in)
kg/km
(1bs/1,000ft)
Install
Long
Term
N (1bf)
N (1bf)
8 (1 x 8)
12 (1 x 12)
24 (1 x 24)
36 (6 x 6)
48 (4 x 12)
72 (6 x 12)
OFNR
4.8 ± 0.2
(0.19 ± 0.01)
N/A
96 (3.8)
48 (1.9)
21 (14)
660 (150)
198 (45)
OFNR
5.4 ± 0.2
(0.21 ± 0.01)
N/A
108 (4.3)
54(2.1)
26 (17)
660 (150)
198 (45)
OFNR
6.2 ± 0.2
(0.24 ± 0.01)
N/A
124 (4.9)
62 (2.4)
32 (22)
660 (150)
198 (45)
OFNR
8.8 ± 0.2
(0.35 ± 0.01)
N/A
176 (6.9)
88 (3.5)
60 (40)
1320 (300)
396 (90)
OFNR
17.1 ± 1.0
(0.67 ± 0.04)
4.8 ± 0.2
(0.19 ± 0.01)
352 (13.9)
176 (6.9)
257 (173)
1320 (300)
396 (90)
OFNR
17.5 ± 1.0
(0.69 ± 0.04)
6.0 ± 0.2
(0.24 ± 0.01)
360 (14.2)
180 (7.1)
236 (159)
1320 (300)
396 (90)
OFNR
21.1 ± 1.0
(0.83 ± 0.04)
6.0 ± 0.2
(0.24 ± 0.01)
432 (17.0)
216 (8.5)
357 (240)
1320 (300)
396 (90)
FIRE PERFORMANCE
ASPECT
NORM
LSZH Sheathing materials
comply fully with the
following standards:
Flammability
IEC 60332 Parts 1 and 3
Smoke emission
IEC 61034 Parts 1 and 2
Acid gas emission
IEC 60754 Parts 1 and 2
Toxicity
NES 60713
318108AE 12/13 www.te.com/enterprise-asia
11. Fiber Optic Cabling
6 (1 x 6)
Long Term
mm (in)
155
Fiber Optic Cabling
Inside Subtitle
Zip Twin and Mini Zip Twin Cable
FEATURES
• Low Smoke Zero Halogen (LSZH)
• Available buffer designs:
• Zip Twin: Tight-Buffer (900µm)
• Mini Zip Twin: Tight-Buffer (600µm)
• Fiber categories: OM1, OM2, OM3 XG, OM4 XGA, OS2
• Tight buffer versions suitable for TE CONNECTIVITY Quick
Termination Products (i.e. LightCrimp or LightCrimp Plus)
ORDERING INFORMATION
Description
Part Number
Fiber count: 2; Cable type: Zip Twin TB
(Tight Buffered Construction)
Y-599142-X
Fiber count: 2; Cable type: Mini Zip Twin TB
(Tight Buffered Construction)
Y-
Reel size
-X
Fiber category
1-
1 Kilometer
-2
OM4 XGA
2-
2 Kilometer
-3
OM3 XG
-4
OS2
-5
OM1
-7
OM2
Y-6206650-X
11. Fiber Optic Cabling
MECHANICAL PERFORMANCE
Fiber count
Overall Ø
(mm)
Weight
(kg/km)
Installation tension max.
during installation (N)
Crush resistance
(N)
Minimum bend radius
during installation (mm)
Zip Twin
2.5 x 5.0
14
300
1000
40
Mini Zip Twin
1.8 x 3.75
6.6
220
2000
25
156
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Inside Subtitle
Indoor Office Distribution Cable (LSZH)
FEATURES
• Universal Low Smoke Zero Halogen (ULSZH)
• For indoor applications
• Suitable for backbone and Fiber-to-the-Desk
• Increased strength and durability
• Tight-Buffer construction
• Suitable for all termination techniques
• Fiber categories: OM1, OM2, OM3 XG, OM4 XGA, OS2
ULSZH jacket
24f
• Aramid strength members
ORDERING INFORMATION
900μ tight buffer
Part Number
Fiber count: 6
Y-599145-X
Fiber count: 8
Y-599146-X
Fiber count: 12
Y-599148-X
Fiber count: 16
Y-599149-X
Fiber count: 24
Y-1716029-X
Fiber count: 36
Y-599602-X
Fiber count: 48
Y-599603-X
Fiber
Y-
Reel size
-X
1-
1 Kilometer
-2
OM4 XGA
2-
2 Kilometers
-3
OM3 XG
3-
3 Kilometers
-4
OS2
4-
4 Kilometers
-5
OM1
-7
OM2
ULSZH jacket
category
Aramid strength
members
Sub unit (4f)
900μ tight buffer
Dielectric central
member
ULSZH jacket
Aramid strength
members
Sub unit (4f)
900μ tight buffer
Dielectric central
member
MECHANICAL PERFORMANCE
Fiber count
Overall Ø
(mm)
Weight
(kg/km)
Installation tension max.
during installation (N)
Crush resistance
(N)
Combustion
Energy (MJ/m)
Minimum bend radius
during installation (mm)
4
5
27
650
2000
0.424
75
6
6
33
1000
2000
0.714
90
8
6
35
1000
2000
0.742
90
12
7.5
56
1000
2000
0.953
115
16
8
61
1000
2000
1.175
120
24
9.5
80
1000
2000
1.513
240
36
17
280
2000
2000
6.199
430
48
17.3
230
2000
2000
6.018
430
318108AE 12/13 www.te.com/enterprise-asia
157
11. Fiber Optic Cabling
Y-599144-X
36f
Fiber count: 4
48f
Description
Aramid strength
members
Fiber Optic Cabling
System Cables
Internal/External Loose Tube Cable 4-144 Fiber (LSZH)
FRP Central
Strength Member
Waterblocking Tape
FEATURES:
• Low Smoke Zero Halogen (LSZH)
Optical Fiber
• For indoor and outdoor applications
Glass Yarns
• For use in ducts applications
• Non-metallic with peripheral strength members
Thixotropic Jelly
Waterblocking Yarn
Ripcord
• Water swelling E-glass yarn (moisture protection)
LSZH
Outer
Sheath
• Dry core technology applied for fiber count more than 12
PBT Loose Tube
• Loose tube construction
• Suitable for all termination techniques
Outer Jacket Color: Black
Optical Fiber
Glass Yarns
Ripcord
X-
Reel size
1-
1 Kilometer
2-
2 Kilometer
Fiber
Count
Fiber Type
LSZH
Outer
Sheath
Cable Jacket
Part Number
Singlemode
LSZH
X-1427436-4
Multimode
LSZH
X-1427436-2
Fiber
Count
11. Fiber Optic Cabling
50/125 μm
4
Multimode
LSZH
8
LSZH
X-1427438-4
Multimode
LSZH
X-1427438-2
LSZH
X-1427438-3
LSZH
X-1427438-5
LSZH
X-1427438-1
LSZH
X-1427438-6
50/125 μm OM3
50/125 μm OM4
LSZH
Multimode
X-1427436-1
62.5/125 μm
LSZH
Multimode
X-1427436-6
50/125 μm OM4+
50/125 μm OM4+
Singlemode
LSZH
X-1427437-4
Singlemode
LSZH
X-1427439-4
Multimode
LSZH
X-1427437-2
Multimode
LSZH
X-1427439-2
LSZH
X-1427439-3
LSZH
X-1427439-5
LSZH
X-1427439-1
LSZH
X-1427439-6
50/125 μm
Multimode
6
Part Number
LSZH
Multimode
X-1427436-5
62.5/125 μm
Multimode
Cable Jacket
Singlemode
Multimode
X-1427436-3
50/125 μm OM4
Multimode
Fiber Type
PBT Loose Tube
50/125 μm
50/125 μm OM3
Multimode
Thixotropic Jelly
50/125 μm
LSZH
Multimode
12
LSZH
X-1427437-5
50/125 μm OM4
Multimode
Multimode
50/125 μm OM3
Multimode
50/125 μm OM4
LSZH
X-1427437-1
62.5/125 μm
50/125 μm OM4+
Multimode
X-1427437-3
50/125 μm OM3
Multimode
62.5/125 μm
LSZH
X-1427437-6
Multimode
50/125 μm OM4+
Ordering information continues next
page.
158
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
System Cables
Fiber
Count
Fiber Type
Cable Jacket
Part Number
Fiber Type
Cable Jacket
Part Number
Singlemode
LSZH
X-1427441-4
Single-mode
LSZH
X-1427457-4
Multimode
LSZH
X-1427441-2
Multimode
50/125 μm
LSZH
X-1427457-2
Multimode
LSZH
X-1427457-3
LSZH
X-1427457-5
LSZH
X-1427457-1
LSZH
X-1427457-6
50/125 μm
Multimode
LSZH
X-1427441-3
50/125 μm OM3
24
Multimode
72
LSZH
Multimode
X-1427441-5
50/125 μm OM4
Multimode
50/125 μm OM4
LSZH
Multimode
X-1427441-1
62.5/125 μm
62.5/125 μm
Multimode
LSZH
Multimode
X-1427441-6
50/125 μm OM4+
50/125 μm OM4+
Singlemode
LSZH
X-1427442-4
Single-mode
LSZH
X-1427458-4
Multimode
LSZH
X-1427442-2
Multimode
LSZH
X-1427458-2
LSZH
X-1427458-3
LSZH
X-1427458-5
LSZH
X-1427458-1
LSZH
X-1427458-6
50/125 μm
50/125 μm
Multimode
LSZH
Multimode
X-1427442-3
50/125 μm OM3
48
50/125 μm OM3
Multimode
96
LSZH
Multimode
X-1427442-5
50/125 μm OM4
Multimode
50/125 μm OM3
50/125 μm OM4
LSZH
Multimode
X-1427442-1
62.5/125 μm
62.5/125 μm
Multimode
LSZH
Multimode
X-1427442-6
50/125 μm OM4+
50/125 μm OM4+
MECHANICAL PERFORMANCE
Fiber count
No of tubes/
fillers
Overall-Ø (mm)
Weight (kg/km)
Installation
tension
max. during
installation (N)
Crush resistance
(N)
Minimum bend
radius during
installation (mm)
4, 6, 8, 12
1
8.0
73
1800
1000
160
24, 48
5
10.8
110
2700
2000
216
72
6
10.9
115
2700
2000
218
96
8
12.3
140
2700
2000
246
318108AE 12/13 www.te.com/enterprise-asia
159
11. Fiber Optic Cabling
Fiber
Count
Fiber Optic Cabling
System Cables
Outside Plant (OSP) Dielectric, 4-48 Fiber (PE)
Optical Fiber
Thixotropic Jelly
FEATURES:
• Suitable for interbuilding backbone
cabling (aerial, duct)
• Small diameter single
tube construction saves
space inside ducts
• TIA color-coded fibers
for easy identification
• Low friction jacket for ease
of pulling through ducts
• Dry core technology applied
for fiber count more than 12
• All-dielectric construction
PBT Loose Tube
Glass Yarns
X-
Reel size
1-
1 Kilometer
2-
2 Kilometer
PBT Loose Tube
Water Blocking Tape
Glass Yarns
Black Outer Sheath
SINGLE LOOSE TUBE
Unit Count
Fiber Unit (Fibers/
Count
Unit)
4
11. Fiber Optic Cabling
6
8
12
24
48
160
1 (4)
1 (6)
1 (8)
1 (12)
2 (12)
4(12)
Thixotropic Jelly
Black PE Filler
FRP Strength Member
Water Blocking Yarn
• Outer Jacket Color is
Black for all Fiber Types
• UV-protected jacket for
harsh outdoor environment
Black Outer Sheath
Optical Fiber
Fiber Type
Part Number
Singlemode
X-1427449-4
Multimode 50/125μm
X-1427449-2
Multimode 50/125 μm OM3
X-1427449-3
Multimode 50/125 μm OM4
X-1427449-5
Multimode 62.5/125 μm
X-1427449-1
Multimode 50/125 μm OM4+
X-1427449-6
Singlemode
X-1427450-4
Multimode 50/125 μm
X-1427450-2
Multimode 50/125 μm OM3
X-1427450-3
Multimode 50/125 μm OM4
X-1427450-5
Multimode 62.5/125 μm
X-1427450-1
Multimode 50/125 μm OM4+
X-1427450-6
Singlemode
X-1427451-4
Multimode 50/125 μm
X-1427451-2
Multimode 50/125 μm OM3
X-1427451-3
Multimode 50/125 μm OM4
X-1427451-5
Multimode 62.5/125 μm
X-1427451-1
Multimode 50/125 μm OM4+
X-1427451-6
Singlemode
X-1427452-4
Multimode 50/125 μm
X-1427452-2
Multimode 50/125 μm OM3
X-1427452-3
Multimode 50/125 μm OM4
X-1427452-5
Multimode 62.5/125 μm
X-1427452-1
Multimode 50/125 μm OM4+
X-1427452-6
Singlemode
X-1427453-4
Multimode 50/125 μm
X-1427453-2
Multimode 50/125 μm OM3
X-1427453-3
Multimode 50/125 μm OM4
X-1427453-5
Multimode 62.5/125 μm
X-1427453-1
Multimode 50/125 μm OM4+
X-1427453-6
Single-mode
X-1427456-4
Multimode 50/125 μm
X-1427456-2
Multimode 50/125 μm OM3
X-1427456-3
Multimode 50/125 μm OM4
X-1427456-5
Multimode 62.5/125 μm
X-1427456-1
Multimode 50/125 μm OM4+
X-1427456-6
Weight
kg/km Diameter Tensile Load N (lbf)
(lb/kft) mm (in) Installation Long Term
Bending Radius
mm (in) Installation
Long Term
48 (32)
7.5(0.30)
1500 (335) 600 (130)
150 (5.9) 75 (3.0)
92 (62)
11.2(0.44)
2700 (600) 890 (200)
224 (8.8) 112 (4.4)
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
System Cables
Outside Plant (OSP) Armored, 4-12 Fiber (PE)
Optical Fiber
Thixotropic Jelly
FEATURES:
• Suitable for inter-building backbone cabling
(aerial, duct or direct buried)
PBT Loose Tube
Glass Yarns
• TIA color-coded fibers for easy identification
Corrugated Steel Tape
• Small diameter single tube construction saves space inside ducts
Black Outer Sheath
• UV-protected jacket for harsh outdoor environment
• Low friction jacket for ease of pulling through ducts
• Corrugated steel tape armor for rugged
environments and rodent protection
X-
Reel size
1-
1 Kilometer
• Outer Jacket Color is Black for all Fiber Types
2-
2 Kilometer
ARMORED SINGLE LOOSE TUBE
4
6
8
12
Unit Count Unit
(Fibers/Unit)
1 (4)
1 (6)
1 (8)
1 (12)
Fiber Type
Part Number
Singlemode
X-1427431-4
Multimode 50/125 μm
X-1427431-2
Multimode 50/125 μm OM3
X-1427431-3
Multimode 50/125 μm OM4
X-1427431-5
Multimode 62.5/125 μm
X-1427431-1
Multimode 50/125 μm OM4+
X-1427431-6
Singlemode
X-1427432-4
Multimode 50/125 μm
X-1427432-2
Multimode 50/125 μm OM3
X-1427432-3
Multimode 50/125 μm OM4
X-1427432-5
Multimode 62.5/125 μm
X-1427432-1
Multimode 50/125 μm OM4+
X-1427432-6
Singlemode
X-1427433-4
Multimode 50/125 μm
X-1427433-2
Multimode 50/125 μm OM3
X-1427433-3
Multimode 50/125 μm OM4
X-1427433-5
Multimode 62.5/125 μm
X-1427433-1
Multimode 50/125 μm OM4+
X-1427433-6
Singlemode
X-1427434-4
Multimode 50/125 μm
X-1427434-2
Multimode 50/125 μm OM3
X-1427434-3
Multimode 50/125 μm OM4
X-1427434-5
Multimode 62.5/125 μm
X-1427434-1
Multimode 50/125 μm OM4+
X-1427434-6
108 (73)
Diameter
mm (in)
Tensile Load N (lbf)
Installation Long
Term
Bending
Radius mm (in)
Installation
Long Term
10.3
(0.41)
2700 (600)
890 (200)
206 (8.1)
103 (4.1)
318108AE 12/13 www.te.com/enterprise-asia
11. Fiber Optic Cabling
Fiber
Count
Weight
kg/km (lb/
kft)
161
Fiber Optic Cabling
System Cables
Outside Plant (OSP) Armored, 24-144 Fiber
Optical Fiber
FEATURES:
Thixotropic Jelly
• Suitable for inter-building backbone cabling
(aerial, duct or direct burial)
PBT Loose Tube
FRP Strength Member
Water Blocking Yarn
• Dry water-blocking technology for cable core
Black PE Filler
• UV-protected jacket for harsh outdoor environment
Water Blocking Tape
• Low friction jacket for ease of pulling through ducts
Corrugated Steel Tape
• Corrugated steel tape for rugged
environments and rodent protection
Black Outer Sheath
• Reverse oscillating lay construction for easy midspan access
• TIA color-coded fibers and buffer tubes for easy identification
• Outer Jacket Color is Black for all Fiber Types
Fibre
Count
24
11. Fiber Optic Cabling
48
72
96
144
162
Unit Count
Unit (Fibers/
Unit)
2 (12)
4 (12)
6 (12)
6 (12)
12 (12)
Fiber Type
Part Number
Singlemode
X-1427435-4
Multimode 50/125 μm
X-1427435-2
Multimode 50/125 μm OM3
X-1427435-3
Multimode 50/125 μm OM4
X-1427435-5
Multimode 62.5/125 μm
X-1427435-1
Multimode 50/125 μm OM4+
X-1427435-6
Singlemode
X-1427444-4
Multimode 50/125 μm
X-1427444-2
Multimode 50/125 μm OM3
X-1427444-3
Multimode 50/125 μm OM4
X-1427444-5
Multimode 62.5/125 μm
X-1427444-1
Multimode 50/125 μm OM4+
X-1427444-6
Singlemode
X-1427445-4
Multimode 50/125 μm
X-1427445-2
Multimode 50/125 μm OM3
X-1427445-3
Multimode 50/125 μm OM4
X-1427445-5
Multimode 62.5/125 μm
X-1427445-1
Multimode 50/125 μm OM4+
X-1427445-6
Singlemode
X-1427446-4
Multimode 50/125 μm
X-1427446-2
Multimode 50/125 μm OM3
X-1427446-3
Multimode 50/125 μm OM4
X-1427446-5
Multimode 62.5/125 μm
X-1427446-1
Multimode 50/125 μm OM4+
X-1427446-6
Singlemode
X-1427448-4
Multimode 50/125 μm
X-1427448-2
Multimode 50/125 μm OM3
X-1427448-3
Multimode 50/125 μm OM4
X-1427448-5
Multimode 62.5/125 μm
X-1427448-1
Multimode 50/125 μm OM4+
X-1427448-6
Weight
kg/km
(lb/kft)
Diameter
mm (in)
Tensile Load N (lbf)
Installation Long
Term
Bending Radius mm
(in)
Installation Long
Term
143 (96)
12.4 (0.49)
2700 (600) 890 (200)
248 (9.8) 124 (4.9)
138 (93)
12.4 (0.49)
2700 (600) 890 (200)
248 (9.8) 124 (4.9)
144 (97)
12.5 (0.49)
2700 (600) 890 (200)
250 (9.8) 125 (4.9)
176 (118)
14.0 (0.55)
2700 (600) 890 (200)
280 (11.0) 140 (5.5)
251 (169)
17.2 (0.68)
2700 (600) 890 (200)
344 (13.54)
(6.77)
www.te.com/enterprise-asia 12/13 318108AE
172
Fiber Optic Cabling
System Cables
Outside Plant (OSP) Figure 8, 4-144 Singlemode Fiber
FEATURES:
• A self supporting optical cable in a figure of 8 configuration,
for aerial installation on poles (except power lines)
Messenger Wire
• Suitable for maximum 80 meters span routes, minimum sag 0.5%
(worst weather condition 108km/hour wind speed, no ice)
Optical Fibers
• Recommend figure 8 cables shall be installed with a full twist,
approx every 7-9 metres, to avoid Galloping.
FRP Strength Member
Jacket Web
Jelly Filled Buffer Tube
CSM Up Coating
• Jelly filled loose tubes and cable core
Jelly Filled Cable Core
• UV-protected jacket for outdoor environment
Polyester Tape
• TIA color-coded fibers and buffer tubes for easy identification
Outer Jacket
• Outer Jacket Color is Black
O.D. mm
Dia. X
Height
Weight
kg/km
Messenger Wire
Dimension
Unit Count x
Unit Dia. mm
Maximum Working
Tension kN (kg)
8.8 x 16.4
142
7 x 1.2
9.4 x 17.0
153
10.0 x 17.6
1-1859411-4
Unit Count
Unit (Fibers/
Unit)
Part
Number
1 (4)
1-1859400-4
6
1 (6)
1-1859401-4
8
2 (6+2)
1-1859402-4
12
2 (6)
1-1859403-4
24
4 (6)
1-1859404-1
36
6 (6)
1-1859408-4
48
4 (12)
1-1859409-4
60
5 (12)
1-1859410-4
72
6 (12)
96
8 (12)
144
12 (12)
4
Bending Radius mm
Installation
Long Term
4.41 (450)
176
88
7 x 1.2
4.9 (500)
188
94
160
7 x 1.2
4.9 (500)
200
100
10.7 x 18.3
174
7 x 1.2
5.69 (580)
214
107
1-1859412-4
12.4 x 20.3
223
7 x 1.3
6.47 (660)
248
124
1-1859413-4
15.6 x 24.4
355
7 x 1.6
9.52 (970)
312
156
318108AE 12/13 www.te.com/enterprise-asia
11. Fiber Optic Cabling
Fiber
Count
163
Fiber Optic Cabling
Patch Panels
Foldable UCP Patch Panel Angled and Flushmount
Please refer to Chapter 4, page 45
Angled Quick-Fit MPO/MPOptimate drawer panel
11. Fiber Optic Cabling
FEATURES
• Accommodates up to 4 MPO/MPOptimate Quick-Fit cassettes
• High-End solution
• Fully integrated and retractable cable management bracket
• Allows for easy Move, Adds and Changes
• Angled style of panels provides additional cable management
towards side area
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Modular MPO/MPOptimate drawer panel for 4 Quick-Fit cassettes, angled
1-1671436-1
164
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Patch Panels
Flush Quick-Fit MPO/MPOptimate drawer panel
FEATURES
• Accommodates up to 4 MPO/MPOptimate Quick-Fit cassettes
• High-End solution
• Fully integrated and retractable cable management bracket
• Allows for easy Move, Adds and Changes
• Flushmount
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Modular MPO/MPOptimate drawer panel for 4 Quick-Fit cassettes, flush
1-1671437-1
Modular MPO/MPOptimate front plate for Quick-Fit cassettes
FEATURES
• Low cost solution
• Flush mount
• Does accept copper and fiber in one panel
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Modular MPO/MPOptimate front plate
1-1671373-1
Quick-Fit Fiber Optic Enclosure
FEATURES
• Suitable for Fiber Optic pre-terminated solution, field direct termination
and splice termination
• 19” enclosure with support for Quick-Fit Modules and splice trays
ORDERING INFORMATION
Description
Part Number
1U Fiber Optic drawer style enclosure for 4 Quick-Fit modules
1933443-1
4U Fiber Optic enclosure for 12 Quick-Fit modules
1553668-1
318108AE 12/13 www.te.com/enterprise-asia
165
11. Fiber Optic Cabling
• Front plate with no additional cable management
Fiber Optic Cabling
Patch Panels
Angled Quick-Fit Fiber Optic Panel
FEATURES
• Suitable for Fiber Optic field direct
termination and splice termination
• Plexi transparent cover
• 19” 1U unloaded with support for 4 Quick-Fit Modules
• One pin splice tray fixation (splice tray NOT included)
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Angled Quick-Fit FO panel
1-1671260-1
Flushmount Quick-Fit Fiber Optic Panel
FEATURES
• Suitable for Fiber Optic field direct termination and splice termination
• 19” 1U unloaded with support for 4 Quick-Fit Modules
• Two pin splice tray fixation (splice tray NOT included)
11. Fiber Optic Cabling
ORDERING INFORMATION
Description
Flushmount Quick-Fit FO panel
166
Part Number
1671149-5
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Patch Panels
1U - LC, SC, ST-Style patch panel, international version
FEATURES
• Drawer style, 1U, 19"
• Preinstalled dust covers on unpopulated ports
• Incl. management rings and metric glands
• Available in ST-Style, SC and LC
• Supplied without splicing tray
Color: black (RAL 9005)
ORDERING INFORMATION
Part Number
24 x ST-Style, Multimode and Singlemode; Unpopulated
1206114-8
24 x ST-Style, Multimode and Singlemode; With 12 adapters
2-1206114-4
24 x ST-Style, Multimode and Singlemode; With 24 adapters
4-1206114-4
24 x SC Duplex, Multimode and Singlemode; Unpopulated
1206343-4
24 x SC Duplex, Multimode; With 24 Beige adapters
4-1206343-4
24 x SC Duplex, Singlemode; With 24 Blue adapters
4-1671002-4
24 x SC Duplex, Multimode; With 12 Aqua adapters
2-1206343-2
24 x SC Duplex, Multimode; With 24 Aqua adapters
4-1206343-2
24 x LC Duplex, Multimode and Singlemode; unpopulated
1671000-8
24 x LC Duplex, Singlemode; With 12 Blue adapters
2-1671000-4
24 x LC Duplex, Multimode; With 12 Beige adapters
2-1671000-8
24 x LC Duplex, Singlemode; With 24 Blue adapters
4-1671000-4
24 x LC duplex, Multimode, With 12 Aqua adaptors
2-1671000-2
24 x LC Duplex, Multimode; With 24 Beige adapters
4-1671000-8
24 x LC duplex, Multimode; With 24 Aqua adaptors
4-1671000-2
318108AE 12/13 www.te.com/enterprise-asia
11. Fiber Optic Cabling
Description
167
Fiber Optic Cabling
Accessories for Patch Panels
ORDERING INFORMATION
Description
Part Number
11. Fiber Optic Cabling
Dust cover for SC Duplex Cut-Out; Packaging: 1
1206121-2
Dust cover for ST-Style Cut-Out; Packaging: 1
1206134-1
PG 9 Gland (3.5-8 mm); Packaging: 50
1206144-1
PG 16 Gland (9-14 mm); Packaging: 50
1206145-1
Cable management ring kit (2 rings); Packaging: 1
1206146-1
Dust cover for SC Simplex/LC Simplex Cut-Out; Packaging: 1
1418800-1
M 20; Packaging: 50
1671054-1
M 25; Packaging: 50
1671054-2
168
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Quick-Fit Modules
Quick-Fit Fiber Modules
FEATURES
• Universal Modules with Quick-Fit footprint
• Fit in all TE CONNECTIVITY Patch Panels
with Quick-Fit footprint
• Not interchangeable with push pin fixation
Color: black (RAL 9005)
Description
Color
Part Number
6 x LC duplex; Fiber Type: OM2; Ferrule: Ceramic
Black
1671196-2
6 x LC duplex; Fiber Type: OM3 XG
10 Gb/s; Ferrule: Ceramic
Aqua
1671196-3
6 x LC duplex; Fiber Type: OS2; Ferrule: Ceramic
Blue
1671196-1
6 x LC/APC duplex; Fiber Type: OS2; Ferrule: Ceramic
Green
1671196-4
6 x LC quad; Fiber Type: OM2; Ferrule: Composite
Beige
1671202-2
6 x LC quad; Fiber Type: OM3 XG 10 Gb/s; Ferrule: Ceramic
Aqua
1671202-3
6 x LC quad; Fiber Type: OS2; Ferrule: Ceramic
Blue
1671202-1
6 x LC/APC quad; Fiber Type: OS2; Ferrule: Ceramic
Green
1671202-4
6 x SC duplex; Fiber Type: OM2; Ferrule: Ceramic
Beige
1671201-2
6 x SC duplex; Fiber Type: OM3 XG
10 Gb/s; Ferrule: Ceramic
Aqua
1671201-3
6 x SC duplex; Fiber Type: OS2; Ferrule: Ceramic
Blue
1671201-1
6x SC/APC duplex; Fiber Type: OS2; Ferrule: Ceramic
Green
1671201-4
6 x ST; Fiber Type: Multimode; metallic
body; Ferrule: Composite
1671195-2
6 x ST; Fiber Type: Singlemode; metallic
body; Ferrule: Ceramic
1671195-1
Blank module
1479698-1
11. Fiber Optic Cabling
ORDERING INFORMATION
MPO/MPOptimate coupler Quick-Fit module
FEATURES
• Quick-Fit module with 6 x MPO coupler
• Port number labeling and additional label strip included
• MPO coupler always used with on one side MPO male and
other side MPO female connector
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
6 x MPO coupler module
1671200-1
12 x MPO coupler module
1711987-1
318108AE 12/13 www.te.com/enterprise-asia
169
Fiber Optic Cabling
Wall Mount Patch Panels
Wall Mount RMG Series Enclosure
FEATURES
• Accept RMG adapter plates or MPO cassettes (sold separately)
• Optical lock available
• Reversible cable strain relief bracket
A
• Recessed, easy-to-use door latches
ORDERING INFORMATION
Capacity
Description
Wall Mount Enclosure
Adapter
Plate
Cassette
Splice
Tray
Figure
2
2
-
A
4
2
-
B
559561-2
6
-
4
C
1278755-4
Optional Lock
Part Number
559560-2
559501-2
Splice Tray Holder (for use with 1278755-4)
1374526-1
11. Fiber Optic Cabling
170
B
www.te.com/enterprise-asia 12/13 318108AE
C
Fiber Optic Cabling
RMG Modules
MPO/MPOptimate RMG module
FEATURES
• Fits in all TE CONNECTIVITY patch panels for RMG modules
ORDERING INFORMATION
Description
Part Number
MPO coupler 6 x 12 fibers (multimode + singlemode); Black
1374598-1
LC RMG Modules
FEATURES
• Fits in all TE CONNECTIVITY patch panels for RMG modules
12 Fibers
ORDERING INFORMATION
Part Number
LC Duplex, 12 fibers (Singlemode), Blue
1374463-1
LC Duplex, 12 fibers (Multimode), Beige
1374463-2
LC Duplex, 12 fibers (Singlemode), Green
1374463-6
LC Duplex, 12 fibers (Multimode), Aqua
1374463-5
LC Duplex, 24 fibers (Singlemode), Blue
1435516-1
LC Duplex, 24 fibers (Singlemode), Green
1435516-6
LC Duplex, 24 fibers (Multimode), Aqua
1435516-5
LC Duplex, 24 fibers (Multimode), Beige
1435516-3
24 Fibers
11. Fiber Optic Cabling
Description
SC RMG Modules
FEATURES
• Fits in all TE CONNECTIVITY Patch Panels for RMG Modules
12 Fibers
ORDERING INFORMATION
Description
Part Number
Duplex SC, 6 fibers (Singlemode), Blue
559558-2
Duplex SC, 6 fibers (Singlemode), Green
559558-7
Duplex SC, 6 fibers (Multimode), Aqua
559558-6
Duplex SC, 6 fibers (Multimode), Beige
559558-4
Duplex SC, 12 fibers (Singlemode), Blue
559596-2
Duplex SC, 12 fibers (Singlemode), Green
559596-3
Duplex SC, 12 fibers (Multimode), Aqua
559596-7
Duplex SC, 12 fibers (Multimode), Beige
559596-4
6 Fibers
318108AE 12/13 www.te.com/enterprise-asia
171
Fiber Optic Cabling
RMG Modules
ST-Style RMG Modules
FEATURES
• Fits in all TE CONNECTIVITY Patch Panels for RMG Modules
ORDERING INFORMATION
12 Fibers
Description
Part Number
ST-Style, 12 fibers (Multimode), Beige
1278567-1
ST-Style, 12 fibers (Singlemode), Blue
1278567-2
ST-Style, 6 fibers (Singlemode), Metallic
559515-2
ST-Style, 6 fibers (Multimode), Metallic
559557-1
SL RMG Modules
FEATURES
• Fits in all TE CONNECTIVITY Patch Panels for RMG modules
ORDERING INFORMATION
Description
Part Number
6 port SL, black
1479506-1
11. Fiber Optic Cabling
RMG blank modules
ORDERING INFORMATION
Description
Part Number
Blank module for panel ≥2 U and wall mount box; Packaging: 1
Blank module, Packaging: 1
172
559523-1
1671146-1
www.te.com/enterprise-asia 12/13 318108AE
6 Fibers
Fiber Optic Cabling
Pre-assembled LC & SC Trunks
Multi fiber pre-assembled trunk cables
FEATURES:
• Factory pre-assembled 6 or 12 fiber trunks
• Simplex connectors at each end (LC/LC, SC/SC or LC/SC)
• LSZH cable loose tube indoor/outdoor cable
• Staggered tails provide easy cable management
• Tail lengths: 4x40+4x50+4x60 (6x50 for 6 fiber cables)
• Other cable constructions/configurations available on request
• The trunks are equipped with midi fan-out and 2mm round tails
protected with transparent protection sleeve
• All cords with protocol, for constant and reliable quality
• Packaging: ≤50 m in box, >50 m on reel
• Re-usable pulling socks can be ordered separately. Part Number 2055567-1
ORDERING INFORMATION
Part Number
2-99 m table A*
12 fiber
assembly
6 fiber
assembly
Part Number
100-500m table B*
SC/SC
OM3
Y-2055665-X
Y-2055666-X
SC/SC
OM4
Y-2055613-X
Y-2055614-X
SC/SC
SM
Y-2055687-X
Y-2055688-X
LC/LC
OM3
Y-2055725-X
Y-2055726-X
LC/LC
OM4
Y-2055583-X
Y-2055584-X
LC/LC
SM
Y-2055727-X
Y-2055728-X
LC/SC
OM3
Y-2055667-X
Y-2055668-X
LC/SC
SM
Y-2255669-X
Y-2055670-X
LC/LC
OM3
Y-2160142-X
Y-2160143-X
LC/LC
OM4
Y-2160144-X
Y-2160145-X
LC/LC
SM
Y-2055740-X
Y-2055741-X
11. Fiber Optic Cabling
Fiber type
* For length tables A and B please refer to page 2 in the MPO/MPOptimate Chapter.
318108AE 12/13 www.te.com/enterprise-asia
173
Fiber Optic Cabling
Pre-assembled LC & SC Trunks
LC Duplex Uniboot - LC Duplex Uniboot
FEATURES
• All assemblies are machine polished providing the highest quality
• Multimode OM3, OM4 and singlemode assemblies have an
ensured performance by Optimized-Physical-Contact (OPC)
• All assemblies are factory tested and come with a test protocol
ORDERING INFORMATION
Y- -X
Length
0- -1
 1 m
Description
Part Number
0- -2
 2 m
OM2
Y-2160404-X
0- -3
 3 m
OM3
Y-2160349-X
0- -5
 5 m
OM4
Y-2160588-X
1- -0
10 m
Description
Part Number
Y- -X
Length
OS2
Y-2105028-X
0- -1
 1 m
OM2
Y-2105026-X
0- -2
 2 m
OM1
Y-2105025-X
0- -3
 3 m
OM3
Y-2105027-X
0- -5
 5 m
OM4
Y-2105061-X
1- -0
10 m
LC Duplex / LC Duplex Patch Cords
FEATURES
• All assemblies are machine polished providing highest quality
• LSZH and OFNR Dual Rated 1.8mm Mini Twin Zip Cable
• All assemblies are factory tested and come with a test protocol
11. Fiber Optic Cabling
ORDERING INFORMATION
174
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Patch Cords and Pigtails
LC Duplex / SC Duplex Patch Cords
FEATURES
• All assemblies are machine polished providing highest quality
• LSZH and OFNR Dual Rated 1.8mm Mini Twin Zip Cable
• All assemblies are factory tested and come with a test protocol
ORDERING INFORMATION
Description
Part Number
Y- -X
Length
OS2
Y-2105032-X
0- -1
 1 m
OM2
Y-2105030-X
0- -2
 2 m
OM1
Y-2105029-X
0- -3
 3 m
OM3
Y-2105031-X
0- -5
 5 m
OM4
Y-2105067-X
1- -0
10 m
LC Duplex / ST-Style Patch Cords
FEATURES
• All assemblies are machine polished providing highest quality
• All assemblies are factory tested and come with a test protocol
ORDERING INFORMATION
Description
Part Number
Y- -X
Length
OS2
Y-2105036-X
0- -1
 1 m
OM2
Y-2105034-X
0- -2
 2 m
OM1
Y-2105033-X
0- -3
 3 m
OM3
Y-2105035-X
0- -5
 5 m
OM4
Y-2105072-X
1- -0
10 m
318108AE 12/13 www.te.com/enterprise-asia
175
11. Fiber Optic Cabling
• LSZH and OFNR Dual Rated 1.8mm Mini Twin Zip Cable
Fiber Optic Cabling
Patch Cords and Pigtails
SC Duplex / SC Duplex Patch Cords
FEATURES
• All assemblies are machine polished providing highest quality
• LSZH and OFNR Dual Rated 2.9mm Twin Zip Cable
• All assemblies are factory tested and come with a test protocol
ORDERING INFORMATION
Description
Part Number
Y- -X
Length
OS2
Y-2105052-X
0- -1
 1 m
OM2
Y-2105050-X
0- -2
 2 m
OM1
Y-2105049-X
0- -3
 3 m
OM3
Y-2105051-X
0- -5
 5 m
OM4
Y-2105076-X
1- -0
10 m
SC Duplex / ST-Style Duplex Patch Cords
FEATURES
• All assemblies are machine polished providing highest quality
• LSZH and OFNR Dual Rated 2.9mm Twin Zip Cable
11. Fiber Optic Cabling
• All assemblies are factory tested and come with a test protocol
ORDERING INFORMATION
Y- -X
Length
Description
Part Number
0- -1
 1 m
OS2
Y-2105056-X
0- -2
 2 m
OM2
Y-2105054-X
0- -3
 3 m
OM1
Y-2105053-X
0- -5
 5 m
OM3
Y-2105055-X
1- -0
10 m
ST-Style Duplex / ST-Style Duplex Patch Cords
FEATURES
• All assemblies are machine polished providing highest quality.
• LSZH and OFNR Dual Rated 2.9mm Twin Zip Cable
• All assemblies are factory tested and come with a test protocol.
ORDERING INFORMATION
Y- -X
Length
Description
Part Number
0- -1
 1 m
OS2
Y-2105060-X
0- -2
 2 m
OM2
Y-2105058-X
0- -3
 3 m
OM1
Y-2105057-X
0- -5
 5 m
OM3
Y-2105059-X
1- -0
10 m
176
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Patch Cords and Pigtails
LC / LC 900µm Patch Cords
FEATURES
• All assemblies are machine polished providing highest quality.
• LSZH Rated
• Can cut into half as two pigtails
• All assemblies are factory tested and come with a test protocol.
ORDERING INFORMATION
Description
Part Number
OS2
Y-2105004-X
OM2
Y-2105002-X
OM1
Y-2105001-X
OM3
Y-2105003-X
Y- -X
Length
0- -2
 2 m
0- -3
 3 m
0- -4
 4 m
Y- -X
Length
0- -2
 2 m
0- -3
 3 m
0- -4
 4 m
SC / SC 900µm Patch Cords
FEATURES
• All assemblies are machine polished providing highest quality.
• LSZH Rated
11. Fiber Optic Cabling
• Can cut into half as two pigtails
• All assemblies are factory tested and come with a test protocol.
ORDERING INFORMATION
Description
Part Number
OS2
Y-2105008-X
OM2
Y-2105006-X
OM1
Y-2105005-X
OM3
Y-2105007-X
318108AE 12/13 www.te.com/enterprise-asia
177
Fiber Optic Cabling
Patch Cords and Pigtails
ST / ST 900µm Patch Cords
FEATURES
• All assemblies are machine polished providing highest quality.
• LSZH Rated
• Can cut into half as two pigtails
• All assemblies are factory tested and come with a test protocol.
ORDERING INFORMATION
Y- -X
Length
Part Number
0- -2
 2 m
Y-2105012-X
0- -3
 3 m
OM2
Y-2105010-X
0- -4
 4 m
OM1
Y-2105009-X
OM3
Y-2105011-X
Description
OS2
11. Fiber Optic Cabling
178
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Adaptors
LC Duplex/LC Duplex Adaptors
FEATURES
• Fits in International Version 1U LC Patch Panel
• Available for singlemode and multimode
ORDERING INFORMATION
Description
Part Number
Multimode, Aqua
1-6457567-6
Multimode, Beige
6457567-8
Singlemode, Blue
6457567-4
SC Duplex/SC Duplex Adaptors
FEATURES
• Fits in International Version 1U SC Patch Panel
• Available for singlemode and multimode
Description
Part Number
Multimode, Aqua
2-5502776-6
Multimode, Beige
5504640-1
Singlemode, Blue
1-5502776-1
11. Fiber Optic Cabling
ORDERING INFORMATION
ST-Style Simplex/ST-Style Simplex 2.5 mm Bayonet Adaptors
FEATURES
• Fits in International Version 1U ST Patch Panel
ORDERING INFORMATION
Description
Part Number
Multimode and Singlemode, Metallic
504021-1
318108AE 12/13 www.te.com/enterprise-asia
179
Fiber Optic Cabling
LightCrimp and LightCrimp Plus
TE CONNECTIVITY LightCrimp Plus Connectors
FEATURES
• Easiest and quickest fiber termination (less than one minute)
• Factory polished for consistent high quality and finish (no paper required)
• No epoxy, curing or UV-light required
• Available for ST-Style, SC and LC
• Complies with the relevant TIA/EIA, IEC, CECC und EN/IS standards
• Durability: 500 cycles
TECHNICAL DATA
• Ferrule: Ceramic
INSTRUCTION SHEET LIGHTCRIMP PLUS
LightCrimp Plus LC; English; Part Number: 408-8925
• Attenuation typical (dB): 0.3 (MM/SM)
LightCrimp Plus SC; English; Part Number: 408-4471
• Temperature range: -10°C to +60°C
LightCrimp Plus ST-Style; English;
Part Number: 408-4457
LightCrimp Plus LC Connectors
FEATURES
• LC connector (simplex or duplex)
• Ceramic ferrule
11. Fiber Optic Cabling
• With pre-installed and pre-polished fiber
ORDERING INFORMATION
Description
Part Number
Simplex LC OS2 (1.6 to 2.0 mm Jacketed Cable); Housing: Blue; Boot: Blue; Packaging: 10
1918626-1
Simplex LC OM1 (1.6 to 2.0 mm Jacketed Cable); Housing: Beige; Boot: Beige; Packaging: 10
1918627-1
Simplex LC OM2 (1.6 to 2.0 mm Jacketed Cable); Housing: Beige; Boot: Black; Packaging: 10
1918627-2
Simplex LC OM3 XG/OM4 XGA (1.6 to 2.0 mm Jacketed Cable); Housing: Beige; Boot: Aqua; Packaging: 10
1918627-3
Simplex LC OS2 APC (250 μm + 900 μm only); Housing: green; Boot: blue; Packaging: 10
2064181-1
Simplex LC OS2 (250 μm + 900 μm only); Housing: blue; Boot: blue; Packaging: 10
6754482-1
Simplex LC OM1 (250 μm + 900 μm only); Housing: Beige; Boot; Beige; Packaging: 10
6754483-1
Simplex LC OM2 (250 μm + 900 μm only); Housing: Beige; Boot: black; Packaging: 10
6754483-2
Simplex LC OM3 XG/OM4 XGA (250 μm + 900 μm only); Housing: Beige; Boot: Aqua; Packaging: 10
6754483-4
Clip to connect two LC simplex to one LC duplex connector; Black (6pc per bag)
1754371-2
180
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
LightCrimp and LightCrimp Plus
LightCrimp Plus SC Connectors
FEATURES
• SC connector (simplex)
• Ceramic ferrule
• With pre-installed and pre-polished fiber
ORDERING INFORMATION
Description
Part Number
2064184-1
Simplex SC OM1 (250 μm + 900 μm + 3 mm jacketed cable);
Body: Beige; Boot: Beige; Packaging: 10;
5492643-1
Simplex SC OM2 (250 μm + 900 μm + 3 mm jacketed cable);
Body: Beige; Boot black; Packaging: 10;
6278079-2
Simplex SC OM3 XG/OM4 XGA 10 Gb/s (250 μm + 900 μm + 3
mm jacketed cable); Body: Beige; Boot: Aqua; Packaging: 10;
6588291-2
Simplex SC OS2 (250 μm + 900 μm + 3 mm jacketed cable);
Body: blue; Boot: blue; Packaging: 10
6693276-1
Clips to connect two SC simplex connectors to one
SC duplex connector (2 clips needed); black
6348522-1
11. Fiber Optic Cabling
Simplex SC OS2 APC; (250 μm + 900 μm only); Body: green;
Boot: Blue; Packaging: 10
LightCrimp Plus ST-Style Connectors
FEATURES
• ST-Style Connectors
• Ceramic ferrule
• With pre-installed and pre-polished fiber
ORDERING INFORMATION
Description
Part Number
Simplex ST OS2 (250 μm + 900 μm + 3 mm jacketed cable);
Boot: black; Packaging: 10
1828953-3
Simplex ST OM1 (250 μm + 900 μm + 3 mm jacketed cable);
Boot: Beige; Packaging: 10
5492642-2
Simplex ST OM2 (250 μm + 900 μm + 3 mm
jacketed cable); Boot: black; Packaging: 10
6278082-1
Simplex ST OM3 XG/OM4 XGA (250 μm + 900 μm + 3 mm
jacketed cable); Boot: Aqua; Packaging: 10
6278082-2
318108AE 12/13 www.te.com/enterprise-asia
181
Fiber Optic Cabling
LightCrimp and LightCrimp Plus
LightCrimp Splice
FEATURES
• Terminates 250 micron coated and 900 micron
tight buffered and 2.0 mm jacketed fibers
• Use with MM and SM 125 micron fibers
• Use with termination toolkit Part Number 1553212-1
• Typical attenuation 0.1 dB
• Typical return loss >20 dB MM and >35 dB SM
• Instruction sheets LightCrimp Splice: Part Number 408-10193
ORDERING INFORMATION
Description
Part Number
LightCrimp Splice for 250 micron coated and 900 micron tight buffered fibers
1985374-1
LightCrimp Splice for 2.0 mm jacketed fiber cable
1985805-1
TE CONNECTIVITY LightCrimp Connector
FEATURES
• Cleave, crimp, polish and connect
11. Fiber Optic Cabling
• High performance pre-radiussed ferrules
• Reduced polishing time
• Durability: 500 cycles
• Each connector comes in a kit containing accessories needed
to terminate to 900 μm buffer, 250 μm coating and 3 mm cable
• Compliant with TIA/EIA, IEC, CECC and EN standards
• No epoxy - just polish
TECHNICAL DATA
• Ferrule: Ceramic or stainless steel • Attenuation (dB): 0.3
INSTRUCTION SHEET LIGHTCRIMP
LightCrimp ST-Style; English: Part Number: 408-9860
LightCrimp SC; English; Part Number: 408-4066
• Temperature range: –40 °C (ceramic) or
–25 °C (stainless steel) to +65 °C
182
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
LightCrimp and LightCrimp Plus
LightCrimp SC Connector
FEATURES
• SC connector (simplex or duplex)
• Ceramic ferrule
• With strain relief and crimp eyelet
ORDERING INFORMATION
Description
Part Number
Simplex SC MM; Ferrule: Ceramic; Packaging: 10
5503692-1
Duplex SC MM; Ferrule: Ceramic; Packaging: 10
5503693-1
Clip to connect two SC simplex connectors to one SC duplex connector (2 clips needed); black
6348522-1
Clip to connect two SC simplex connectors to one SC duplex connector (2 clips needed); green
6348522-2
Clip to connect two SC simplex connectors to one SC duplex connector (2 clips needed); blue
6348522-3
Clip to connect two SC simplex connectors to one SC duplex connector (2 clips needed); beige
6348522-4
11. Fiber Optic Cabling
LightCrimp ST-Style Connector
FEATURES
• ST-Style connector
• Multimode and singlemode
• With strain relief and crimp eyelet
ORDERING INFORMATION
Description
Part Number
Singlemode ST-Style; Ferrule: Ceramic; Packaging: 1
5504000-1
Multimode ST-Style; Ferrule: Stainless steel; Packaging: 100
5504034-1
Multimode ST-Style; Ferrule: Ceramic; Packaging: 100
5504600-1
318108AE 12/13 www.te.com/enterprise-asia
183
Fiber Optic Cabling
Epoxy Connectors
LC Connector Kits
FEATURES
• Multimode and singlemode (Telcordia GR-326 tested and
TIA/EIA 568-B.3 qualified)
• Universal connector body:
- common body for simplex or duplex
- common body for jumper or buffer applications
• Field installable duplex clip
• Improved side load strength
• Attenuation typ. < 0.2 dB
• Temperature range -40 °C to +85 °C
• Durability: 0.2 dB change after 500 cycles (MM)
ORDERING INFORMATION
Description
Part Number
11. Fiber Optic Cabling
Type: Simplex; Ferrule: Ceramic; Boot: 1.6-2.0 mm; Blue; Fiber type: SM
1918266-1
Type: Simplex; Ferrule: Ceramic; Boot: 1.6-2.0 mm; Beige; Fiber type: MM
1918267-1
Type: Simplex; Ferrule: Ceramic; Boot: 1.6-2.0 mm Aqua; Fiber type: OM3/OM4
1918267-3
Type: Simplex; Ferrule: Ceramic; Boot: 3.0 mm; Blue; Fiber type: SM
1918374-1
Type: Simplex; Ferrule: Ceramic; Boot: 3.0 mm; Beige; Fiber type: MM
1918375-1
Type: Simplex; Ferrule: Ceramic; Boot: 3.0 mm; Aqua; Fiber type: OM3/OM4
1918375-3
Type: Simplex; Ferrule: Ceramic; Boot: 0.9 mm; Blue; Fiber type: SM
1918384-1
Type: Simplex; Ferrule: Ceramic; Boot: 0.9 mm; Beige; Fiber type: MM
1918385-1
Type: Simplex; Ferrule: Ceramic; Boot: 0.9 mm; Aqua; Fiber type: OM3/OM4
1918385-3
Clip to connect two LC simplex to one LC duplex connector, Black (6pc per bag)
1754371-2
184
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Epoxy Connectors
SC Connector Kits
FEATURES
• High performance pre-radiussed ferrules
• SC compatible JIS C-5973
• Multimode or singlemode
• Durability: 0.2 dB change after 1000 cycles (MM)
• Temperature range: -40°C to +85°C
• Attenuation typ. < 0.2 dB
• Available in simplex and duplex
ORDERING INFORMATION
Description
Part Number
Simplex; Ferrule: Ceramic; Boot: 0.9 mm; Beige; Crimp eyelet: no; Fiber type: MM
5504932-1
Simplex; Ferrule: Ceramic; Boot: 0.9 mm Aqua; Crimp eyelet: no; Fiber type: OM3/OM4
5504932-5
Simplex; Ferrule: Ceramic; Boot: 0.9 mm; Blue: Crimp eyelet: no; Fiber type: SM
5492123-1
Simplex; Ferrule: Ceramic; Boot: 3 mm; Beige: Crimp eyelet: yes; Fiber type: MM
Simplex; Ferrule: Ceramic; Boot: 3 mm Aqua; Crimp eyelet: yes; Fiber type: OM3/OM4
5503948-1
1-5503948-0
5504646-1
Clip to connect two SC simplex- to one SC duplex connector; black.
6348522-1
11. Fiber Optic Cabling
Simplex; Ferrule: Ceramic; Boot: 3 mm; Blue: Crimp eyelet: yes; Fiber type: SM
318108AE 12/13 www.te.com/enterprise-asia
185
Fiber Optic Cabling
Epoxy Connectors
ST-Style Connector Kits
FEATURES
• High performance pre-radiussed ferrules
• ST-Style compatible bayonet coupling
• Multimode or singlemode
• Durability: 0,2 dB change after 1000 cycles (MM)
• Temperature range: -20°C to +75°C
• Attenuation typ. < 0,3 dB
• Available in DieCast and overmolded (OVM) version
ORDERING INFORMATION
Description
Part Number
Bend limiting buffer boots (100 pcs); 0.9 mm; black
5503628-1
Bend limiting cable boots (100 pcs); short; 3 mm; black
501457-1
Bend limiting cable boots (100 pcs); short; 3 mm; red
501457-3
Ferrule: Ceramic; Connector body/bayonet: DieCast/Metal; 3 mm boot: no;
0.9 mm boot: yes; Crimp eyelet: yes; Fiber type: SM
5503613-2
Ferrule: Ceramic; Connector body/bayonet: DieCast/Metal; 3 mm boot: yes;
0.9 mm boot: no; Crimp eyelet: yes; Fiber type: SM
5502580-2
11. Fiber Optic Cabling
Ferrule: Ceramic; Connector body/bayonet: OVM/Metal; 3 mm boot: no;
0.9 mm boot: no; Crimp eyelet: yes; Fiber type: MM
503676-1
Ferrule: Ceramic; Connector body/bayonet: OVM/Metal; 3 mm boot: yes;
0.9 mm boot: no; Crimp eyelet: yes; Fiber type: MM
503677-1
186
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Splicing Products
Splice Trays
FEATURES
• Splice trays delivered with cover
• Splice protectors not included in tray
A
ORDERING INFORMATION
Description
Part Number
For 24 SMOUV (62 mm) splice protectors, figure A
1671281-1
For 24 ANT splice protectors, figure B
1671281-2
For 24 RECORDsplice splices, figure C
1671281-3
ANT splice protector; Packaging: 150
182398-000
SMOUV splice protector (62 mm); Packaging: 100
657054-000
B
11. Fiber Optic Cabling
C
318108AE 12/13 www.te.com/enterprise-asia
187
Fiber Optic Cabling
Splicing Products
TE CONNECTIVITY CORELINK Mechanical Splice
Mechanical Quick Termination
The CORELINK splice is easy to use, high performance mechanical splice for 125 µm
singlemode and multimode fibers. Its unique clamping mechanism is activated with
a simple key, no other tool is required. The splice is remateable - either fiber can be
removed and replaced in the splice at any time.
FEATURES
• No fusion splice necessary
• Torsion resistant
• Bellcore TR-765 tested
• For multimode and singlemode
• For tight buffer, semi-tight and loose tube
• For 250 μm coating and 900 μm buffer
• Cleaning Tools
• Light Crimp Universal Cleave Tool
• Fiber Optic Cleave Tool for Field Installations
11. Fiber Optic Cabling
TECHNICAL DATA:
SinglemodeMultimode
• Color: transparent
Color: transparent blue
• Attenuation typical (dB): ≤ 0.3
Attenuation typical (dB): ≤ 0.3
• Return loss typical (dB): –35 dB (min)
Return loss typical (dB): -20 dB (min)
• Application: SM
Application: MM
• Temperature range: –10°C to +60°C
Temperature range: –10°C to +60°C
• Dimensions: 51 x 7.6 x 3.3 mm
Dimensions: 51 x 7.6 x 3.3 mm
CORELINK Splices
FEATURES
• Mechanical splice
• Re-usable
ORDERING INFORMATION
Description
Part Number
12 CORELINK Splices for single- and multimode
503577-1
2 Replacement keys in key holder
503681-1
188
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Splicing Products
Splice Holder for CORELINK Splices
FEATURES
• 31.8 x 61.0 mm Elastomer holder for 6 or 12 CORELINK splices
• For mount in splice boxes or in distribution boxes
ORDERING INFORMATION
Description
Part Number
Splice holder for 6 CORELINK splices
559066-1
Splice holder for 12 CORELINK splices
559087-1
Workstation for CORELINK Splices
FEATURES
• For easy and safe installation of the CORELINK splices
ORDERING INFORMATION
CORELINK Cleave tool
CORELINK Workstation
Part Number
1871696-1
11. Fiber Optic Cabling
Description
503605-1
318108AE 12/13 www.te.com/enterprise-asia
189
Fiber Optic Cabling
Splicing Products
LightCrimp Plus Termination Tool Kits
FEATURES
• Termination Tool kit includes:
– Pro-Crimper II Hand Tool and appropriate die set
– Stripper tools
– Kevlar scissor
– Cable holder
– Cleave tool
ORDERING INFORMATION
Description
Part Number
LightCrimp Plus ST-Style Connector Termination Tool Kit without microscope
492697-1
LightCrimp Plus ST-Style Connector Termination Tool Kit with microscope
492697-2
LightCrimp Plus ST-Style, SC and LC Connectors Termination Tool Kit without microscope
1278118-4
LightCrimp Plus ST-Style, SC and LC Connectors Termination Tool Kit with microscope
1278118-5
LightCrimp Plus LC, SC and LightCrimp Splice Termination Tool Kit without microscope
1553212-1
LightCrimp Plus LC and SC Connector Termination Tool Kit without microscope
1754845-1
LightCrimp Plus LC and SC Connector Termination Tool Kit with microscope
1754845-2
11. Fiber Optic Cabling
LightCrimp Termination Tool Kit
FEATURES
• Termination tool kit includes:
– PRO-CRIMPER II Hand Tool and appropriate die set
– Stripper tools
– Kevlar scissor
– Template strip
– Cleave tool
– Polishing bushings
– Polishing films
– Polishing plate
– Microscope as listed
• Microscope separately available
ORDERING INFORMATION
Description
Part Number
LightCrimp SC and ST-Style; Type: Mini Tool Kit; Microscope: No Microscope
492543-1
LightCrimp ST-Style; Type: Termination Kit; Microscope: No Microscope
503330-1
LightCrimp SC and ST-Style; Type: Termination Kit; Microscope: No Microscope
503957-1
LightCrimp SC and ST-Style; Type: Termination Kit; Microscope: Premium Microscope
503957-3
190
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Fiber Optic Tools
Pro-Installer Epoxy/Polish Type Connector Termination Tool Kit
FEATURES
• Includes all tools necessary to install the following connectors:
ST-Style, TE CONNECTIVITY SC, FSD, FC, D4, FSMA
(Epoxy sold separately)
• Tool kits include (except otherwise specified):
– PRO-CRIMPER II Hand Tool and crimping dies
– Polishing bushings
– Polishing film
– Cable and fiber strippers
– Scissors
– Scribe tool
– Microscope with tripod and power source
– Epoxy curing oven
ORDERING INFORMATION
Description
Part Number
Tool kit with 240V curing oven and with microscope
501258-8
1754462-1
11. Fiber Optic Cabling
LC Upgrade Kit
318108AE 12/13 www.te.com/enterprise-asia
191
Fiber Optic Cabling
Fiber Optic Tools
Epoxy/Polish Type Connector Termination Tool Kit
FEATURES
• Tool kits include:
– Carrying case
– PRO-CRIMPER II Hand Tool and crimping dies
– Polishing bushings
– Polishing film
– Cable and fiber strippers
– Scissors
– Scribe tool
• Kits contain polishing materials for approximately 60 connectors
(consumables can be purchased separately)
• SC tool kit can also be used to install FC Connectors
ORDERING INFORMATION
Description
Part Number
LC Upgrade Kit
1754603-1
ST-Style
503746-1
SC and FC
503746-7
11. Fiber Optic Cabling
Universal No Epoxy Termination Tool Kit
FEATURES
• Includes all tools necessary for installing:
– LightCrimp Plus ST-Style, SC and LC connectors
– LightCrimp ST-Style and SC connectors
• Termination Tool kit includes:
– PRO-CRIMPER II Hand Tool and appropriate die set
– Stripper tools
– Kevlar scissor
– Cable holder
– Cleave tool
– LightCrimp Plus Termination Video CD-Rom
ORDERING INFORMATION
Description
Part Number
Universal no epoxy termination tool kit without microscope
1278949-2
Universal no epoxy termination tool kit with microscope
1278949-3
192
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Fiber Optic Tools
LightCrimp Universal Cleave Tool
FEATURES
• Used in both SC and ST-Style LightCrimp connector terminations
• Included in all LightCrimp tool kits
ORDERING INFORMATION
Description
Part Number
LightCrimp Universal Cleave Tool
503705-1
LightCrimp Plus Cable Holder
FEATURES
• Stripping template and cable holder for LightCrimp Plus terminations
• Included in the LightCrimp Plus tool kit
ORDERING INFORMATION
Part Number
LightCrimp splice cable holder
1985771-1
LC and SC
2064540-1
ST-Style
11. Fiber Optic Cabling
Description
492703-1
Fiber Optic Cleave Tool for Field Installations
FEATURES
• Applicable to LightCrimp Plus Connector and CORELINK terminations
• Lifespan of blade is approximately 10000 cycles
• Cleaving length: 4, 6, 8, 10, 16 mm
• For 900 μm and 250 μm fiber
ORDERING INFORMATION
Description
Fiber Optic Cleave Tool
Part Number
1871696-1
318108AE 12/13 www.te.com/enterprise-asia
193
Fiber Optic Cabling
Fiber Optic Tools
Separate Tools
FEATURES
• Stripping tools, Micro-Stripper and Kevlar scissor
for easy and save fiber preparation
ORDERING INFORMATION
Description
Part Number
Solid Steel Kevlar Scissor
501014-1
Stripping tool for cable jackets (red handles)
1278531-1
Cable Jacket Clamp
1278625-1
Kevlar shears (blue handle)
1278637-1
Miller Stripping tool for buffer, fiber coating and 2-3 mm jackets (yellow handles)
1754708-1
Micro-Strip 2 mm Cable Jacket Splitter
2064453-2
Micro-Stripper for 900 μm buffer
492109-2
Jacket stripper
501198-1
Pro Crimper II Hand Tool and Fiber Optic Die Sets
11. Fiber Optic Cabling
FEATURES
• Hand tool and die sets for fiber optic connectors
ORDERING INFORMATION
Description
Part Number
Die Set: LC and SC Epoxy; Cable Jacket Diameter: 1.6-2.0 & 2.4 & 3.0 mm (3.0mm for LC only)
1588175-1
Die Set: LightCrimp Plus and LightCrimp ST-Style; Cable Jacket Diameter: 3.0 mm
492622-1
Die Set: LightCrimp Plus and LightCrimp SC; Cable Jacket Diameter: 3.0 mm
492783-1
Die Set: LightCrimp Plus LC and SC and LightCrimp Splice; Cable Diameter: 2.0 mm
1985766-1
Die Set: SC; Cable Jacket Diameter: 2.4 & 3.0 mm
492025-1
Die Set: SC; Cable Jacket Diameter: 3.0 mm
503910-1
Die Set: ST-Style; Cable Jacket Diameter: 3.0 mm
Hand Tool and Die Set: LC and SC Epoxy; Cable Jacket Diameter: 1.6 – 2.0 & 2.4 & 3.0 mm (3.0mm for LC only)
58424-1
1588176-1
Hand Tool and Die Set: LightCrimp Plus and LightCrimp SC; Cable Jacket Diameter: 3.0 mm
492782-1
Hand Tool and Die Set: LightCrimp Plus and LightCrimp ST-Style; Cable Jacket Diameter: 3.0 mm
492623-1
Hand Tool and Die Set: LightCrimp Plus LC and SC and LightCrimp Splice; Cable Jacket Diameter: 2.0 mm
2064603-1
Hand Tool and Die Set: LightCrimp Plus LC; Cable Jacket Diameter: 1.6-2.0 mm
1754137-1
Hand Tool and Die Set: SC; Cable Jacket Diameter: 2.4 & 3.0 mm
492026-1
Hand Tool and Die Set: SC; Cable Jacket Diameter: 3.0 mm
503911-1
Hand Tool and Die Set: ST-Style; Cable Jacket Diameter: 3.0 mm
PRO-CRIMPER II Hand Tool only
194
58433-4
2064431-1
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Fiber Optic Tools
Sapphire Tipped Scribe Tool and Accessories
FEATURES
• Long-lasting sapphire blade
• Pen-type casing
• For epoxy style connectors only
ORDERING INFORMATION
Description
Part Number
Sapphire tipped Scribe Tool
504064-1
Replacement Blades
504290-1
Polishing Bushings, Curing Sleeves and Strip Card Kit
FEATURES
• Polishing bushings for all polishing processes
• Curing sleeves for safe oven application
Description
11. Fiber Optic Cabling
ORDERING INFORMATION
Part Number
Curing sleeve; Used with: LC 900 μm; Notes: 12 pcs
1457630-1
Curing sleeve; Used with: LC jacketed cable; Notes: 12 pcs
1457630-2
Strip Card Kit; Used with: LC Connectors; Notes: -
1588756-1
Polishing bushing; Used with: Ceramic LC Connectors; Notes: Metal
1754074-1
Strip Card Kit; Used with: ST-Style and SC Connectors
501818-1
Alcohol Wipes 200 packet/box
501857-2
Curing sleeve; Used with: Ceramic, stainless steel and
Polymer composite ST-Style connectors; Notes: 12 pcs.
502259-1
Polishing bushing; Used with: SC Connectors; Notes: black Polymer
502631-1
Curing sleeve; Used with: SC Connectors; Notes: 1 pc.
502656-1
Polishing bushing; Used with: Ceramic, stainless steel and
Polymer composite ST-Style connectors; Notes: black Polymer
503304-1
Polishing bushing; Used with: Ceramic and stainless
steel ST-Style connectors; Notes: Metal
503337-1
Polishing bushing; Used with: SC Connectors; Notes: Metal
503787-1
318108AE 12/13 www.te.com/enterprise-asia
195
Fiber Optic Cabling
Fiber Optic Tools
Polish Pads
FEATURES
• Acryl polishing plate
• Self-adhesive polishing pad
ORDERING INFORMATION
Description
Part Number
Polishing plate 8.5x11 inch
501197-1
Polishing pad for polymer ferrules 21 cm diameter, white, self-adhesive
501523-1
Polishing pad for ceramic ferrules 21 cm diameter, white, self-adhesive
501858-1
Epoxy Curing Oven
FEATURES
• Reduces time required to cure epoxy in fiber optic connectors
• Accepts all TE CONNECTIVITY Fiber Optic Connectors that require epoxy
• Comes equipped to cure up to four duplex connectors and
12 simplex connectors at once
• Optional blocks to allow up to 8 duplex and 24 simplex connectors available
• Variable temperature control (60°C to 125°C)
11. Fiber Optic Cabling
• Includes thermometer and cable support bracket
ORDERING INFORMATION
Description
Part Number
Adapter block for 1.6, 2.0 and 2.4 mm SC and LC connectors
1457628-1
Adapter block for 24 single connectors
502129-1
Curing oven (220 Volt) incl. adapter block for 16 connectors
502134-2
Adapter block for 8 duplex connectors
502222-1
EPO-TEK 353ND epoxy
FEATURES
• Pre-measured bi-packs for consistent results
• Ideal for bonding fibers and optical components
• Long pot life
• Heat-cured and room-temperature epoxy
• High service temperature
• Supplied in 4-gram packs
ORDERING INFORMATION
Description
Part Number
EPO-TEK 353ND; Cure time/Temp.: 10min @ 115°C; Pot
life: +/- 30 min; Color after Curing: red; Viscosity (cps):
2000; Max. Temp.: 200°C; Glass transition-temp: 124°C
196
504035-1
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Fiber Optic Tools
TRA-CON (R) and Hysol (R) Epoxy
FEATURES
• General purpose epoxy for SC and ST-Style epoxy polish connectors
• Long pot life
• Heat-cured and room-temperature epoxy
• High service temperature
ORDERING INFORMATION
Description
Part Number
Application: For manufacturing and field use; Connectors: FDDI,
ESCON, ST-Style, FSMA; Cure time and temperature:
24 hr@ 25°C, 2 hr @ 65°C; Pot life: 30 mins; Color: blue;
Packaging: 25 x 2 g; Connectors pro package: 250
Application: For manufacturing and field-use; Connectors: all; Cure
time and temperature: 30 mins @ 100°C;
Pot life: 30 mins; Color: blue; Packaging: 1 x 70.8 g
+ 1 x 22.6 g; Connectors pro package: 400
1918652-1
502418-1
FEATURES
• 3 ccl capacity
• Ideal for epoxy
ORDERING INFORMATION
Description
Part Number
Hand Polishing Film (Packet of 15); Connector Type: Epoxy-Polish LC; Grit Grade: 0.9 μm
1374484-1
Hand Polishing Film (Packet of 100); Connector Type: Epoxi-Polish SC,
Epoxi-Polish Singlemode ST-Style, Epoxi-Polish Multimode ST-Style,LightCrimp SC and ST-Style; Grit Grade: 0.3 μm
228433-5
Hand Polishing Film (Packet of 100); Connector Type: Epoxi-Polish Multimode
ST-Style, LightCrimp SC and ST-Style; Grit Grade: 1 μm
228433-7
Hand Polishing Film (Packet of 100); Connector Type: Epoxi-Polish SC,
Epoxi-Polish Singlemode ST-Style, Epoxi-Polish Multimode ST-Style,LightCrimp SC and ST-Style; Grit Grade: 5 μm
228433-8
Hand Polishing Film (Packet of 100);
Connector Type: LightCrimp SC and ST-Style; Grit Grade: 15 μm
228433-9
Adhesive applicator syringe
501473-3
Mixing cup
502282-2
Hand Polishing Film (Packet of 5);
Connector Type: Epoxi-Polish SC, Epoxi-Polish Singlemode ST-Style
502748-2
318108AE 12/13 www.te.com/enterprise-asia
197
11. Fiber Optic Cabling
Adhesive Applicator Syringe and Polishing Films
Fiber Optic Cabling
Fiber Cleaning and Inspection
Optical Fiber Inspection and Cleaning Kits
FEATURES
• Densely woven micro-fiber cloth cleans fiber optic
connector tips and reduces static charge
• Reel cleaners that work with FC, SC, ST and
MT-RJ connectors, as well as PARA-OPTIX products
• Stick cleaners with perforated handles for
customizing length and angle
• High resolution, 200x microscope to
visual inspect connectors before mating
ORDERING INFORMATION
Description
Part Number
11. Fiber Optic Cabling
Optical Fiber and Cleaning Kit A
1x Visual Fault Locator (VFL) with 1.25 mm Adapter
1x 200x Microscope with 2.5 mm Adapter
1x 1.25 mm (LC) Microscope Adapter
1x MT-RJ Microscope Adapter
1x MPOA Microscope Adapter
1x MPO Microscope Adapter
1x Termination Training, CD-ROM
5x 2.5 mm Stick Cleaners (10/Package)
5x 1.25 mm Stick Cleaners (10/Package)
1x One Slot Reel Cleaner
1x MT-RJ w/pins Reel Cleaner
1x SC in Bulkhead Cleaner (IBC)
1x LC IBC
1x MPO IBC
1x Premium Hardcase
2064651-1
Optical Fiber and Cleaning Kit B
1x Visual Fault Locator (VFL) with 1.25 mm Adapter
1x 200x Microscope with 2.5 mm Adapter
1x 1.25 mm (LC) Microscope Adapter
1x MT-RJ Microscope Adapter
1x Termination Training, CD-ROM
5x 2.5 mm Stick Cleaners (10/Package)
5x 1.25 mm Stick Cleaners (10/Package)
1x One Slot Reel Cleaner
1x MT-RJ w/pins Reel Cleaner
1x SC in Bulkhead Cleaner (IBC)
1x LC IBC
1x Premium Hardcase
2064651-2
Optical Fiber and Cleaning Kit C
1x Visual Fault Locator (VFL) with 1.25 mm Adapter
1x 200x Microscope with 2.5 mm Adapter
1x 1.25 mm (LC) Microscope Adapter
1x Termination Training, CD-ROM
5x 2.5 mm Stick Cleaners (10/Package)
5x 1.25 mm Stick Cleaners (10/Package)
1x One Slot Reel Cleaner
1x SC in Bulkhead Cleaner (IBC)
1x LC IBC
1x Premium Hardcase
2064651-3
198
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Fiber Cleaning and Inspection
MPO/LC/SC/MT-RJ Cassette Cleaners
ORDERING INFORMATION
Description
Part Number
MTP/MPO with pins; Packaging: 1
1918802-1
1 Slot Reel Cleaner for MPO/LC/SC and MT-RJ; Packaging: 1
1918803-1
MT-RJ with pins Reel Cleaner; Packaging: 1
1918804-1
2 Slot reel cleaner for LC and SC; Packaging: 1
1918805-1
Cleaner Refill; Packaging: 6 rolls
1918806-1
MPO Coupler Cleaner
ORDERING INFORMATION
Description
Part Number
MPO IBC; Packaging: 1
1918809-1
11. Fiber Optic Cabling
Card Cleaner
ORDERING INFORMATION
Description
Part Number
Card Cleaner; Packaging: 1
1918810-1
Card Cleaner Refill; Packaging: 100 sheets
1918811-1
Cleaning Sticks for Single Fiber Couplers
ORDERING INFORMATION
Description
Part Number
2.5 mm stick cleaner; Packaging: 25 x 10
1918807-1
1.25 mm stick cleaner; Packaging: 25 x 10
1918808-1
LC/SC bulkhead cleaner
ORDERING INFORMATION
Description
Part Number
SC IBC (In Bulkhead Cleaner)
2064499-1
LC IBC (In Bulkhead Cleaner)
2064500-1
318108AE 12/13 www.te.com/enterprise-asia
199
Fiber Optic Cabling
Fiber Cleaning and Inspection
Inspection Microscope
FEATURES
• Optimal visual examination of terminated ends
• 500 μm field of view
• Dual illumination
• Coaxial for inspecting polish quality
• Oblique for general conditions
• Field and laboratory examination for multimode and singlemode fibers
• Portable
• Integral infrared filters for safety
• Do NOT use any microscope to view active fiber signals
• Disposable, Type LR44 batteries
• Long-life LED (appr. 100.000 hours of operation)
•
• Each kit contains:
−− 10-power objective microscope with an impact resistant ergonomic rubber shell and high quality glass optics
−− 20-power eyepiece
−− Padded carrying case with an integrated belt loop and internal adapter storage pocket
−− Neck lanyard with safety breakaway feature
−− Universal 2.5 mm ferrule adapter (for SC, ST and FC)
11. Fiber Optic Cabling
ORDERING INFORMATION
Description
Part Number
1.25 mm universal (LC and MU adapter)
1754765-1
2.50 mm universal (SC, ST-Style and FC adapter)
1754766-1
Inspection Microscope Kit
1754767-1
MT-RJ adapter
1754768-1
SC/APC adapter
1828833-1
MPO adapter
1828836-1
MPO APC adapter
1828837-1
1.25 mm universal LC duplex adapter
2123273-1
1.25 mm LC APC adapter
1553785-1
200
www.te.com/enterprise-asia 12/13 318108AE
Fiber Optic Cabling
Fiber Cleaning and Inspection
Visual Fault Locator
FEATURES
• 650 μm (visible) Class 2 1.0 mW max. Diode Laser
• Continuous and flashing (2-3 Hz pulsed) modes
• Uses 1 “AA” style battery for >30 hours of continuous use
• Standard 2.5 mm adapter for SC, ST, and FC connectors
• Optional 1.25 mm adapter for LC and MU connectors
ORDERING INFORMATION
Description
Part Number
Hand Held Visual Fault Locator incl. 2.5 mm adaptor
1828352-1
Hand Held Visual Fault Locator incl. 2.5 + 1.25 mm adaptor
1828352-2
Adaptor for Hand Held VFL 1.25 mm
1828353-1
OTDR Launch Lead Kits for Optical Testing and Certification
FEATURES
• Each kit contains:
−−Launch and tail lead
11. Fiber Optic Cabling
−−Length 400 m (MM) and 500 m (SM)
−−Data sheet of end face geometry
−−Coupling bushings
−−Cleaning aides
−−Instruction manual
Y- -X
Connector Type
Y- -X
Connector Type
Y- -X
Connector Type
Y- -X
Connector Type
0- -1
SC/PC to SC/PC
0- -6
ST/PC to SC/PC
1- -1
LC/PC to SC/PC
1- -6
FC/PC to SC/PC
0- -2
SC/PC to ST/PC
0- -7
ST/PC to ST/PC
1- -2
LC/PC to ST/PC
1- -7
FC/PC to ST/PC
0- -3
SC/PC to LC/PC
0- -8
ST/PC to LC/PC
1- -3
LC/PC to LC/PC
1- -8
FC/PC to LC/PC
0- -4
SC/PC to PC/PC
0- -9
ST/PC to PC/PC
1- -4
LC/PC to PC/PC
1- -9
FC/PC to PC/PC
0- -5
SC/PC to MT-RJ
1- -0
ST/PC to MT-RJ
1- -5
LC/PC to MT-RJ
2- -0
FC/PC to MT-RJ
ORDERING INFORMATION
Description
Part Number
OM2-OM3 and OM4 Launch Lead
Y-6695240-X
OM1 Launch Lead
Y-6695242-X
OS2 Launch Lead
Y-6695244-X
318108AE 12/13 www.te.com/enterprise-asia
201
Fiber Optic Cabling
Fiber Cleaning and Inspection
Power meter testlead Kits for Optical Testing and Certification
FEATURES:
• Simplex Test leads
• LSZH cable, Length 3 meter
• Data sheet of end face geometry packed per assembly
• MOQ: 6 per item
ORDERING INFORMATION
Description
Part Number
50 micron test lead for OM2-OM3 and OM4 Attenuation test
SC/PC to SC/PC
2160547-3
SC/PC to LC/PC
2160548-3
LC/PC to LC/PC
2160549-3
9 micron test lead for SM OS1 and SM OS2 Attenuation test
SC/PC to SC/PC
2160550-3
SC/PC to LC/PC
2160551-3
LC/PC to LC/PC
2160552-3
11. Fiber Optic Cabling
202
www.te.com/enterprise-asia 12/13 318108AE
12. Modular Twisted Pair Cabling
Category 7A
Cable...........................................................................................................................204
Jacks...........................................................................................................................205
Consolidation Point..............................................................................................206
Patch Cords............................................................................................................. 207
Category 6A
Cable............................................................................................................................. 211
Jacks............................................................................................................................ 213
Patch Panels............................................................................................................. 215
Consolidation Point............................................................................................... 216
Patch Cords.............................................................................................................. 217
HighBand................................................................................................................... 219
Category 6
Cable........................................................................................................................... 226
Jacks........................................................................................................................... 228
Outlets........................................................................................................................ 231
Patch Panels............................................................................................................ 232
Consolidation Point.............................................................................................. 234
Patch Cords............................................................................................................. 236
HighBand.................................................................................................................. 238
Category 5e
Cables........................................................................................................................ 245
Jacks........................................................................................................................... 247
Patch Panels............................................................................................................ 249
Consolidation Point.............................................................................................. 252
Patch Cords............................................................................................................. 253
110Connect XC System....................................................................................... 256
HighBand..................................................................................................................260
Voice
Backbone Cable.................................................................................................... 266
Jacks........................................................................................................................... 267
Patch Panels............................................................................................................ 269
LSA-PLUS................................................................................................................. 270
Indoor Boxes............................................................................................................275
Unloaded Hardware
Patch Panels............................................................................................................ 278
Consolidation Box................................................................................................. 282
Faceplates................................................................................................................ 283
Outlets.......................................................................................................................284
Surface Mount Boxes.......................................................................................... 286
Twisted Pair Tools..................................................................................................... 288
318108AE 12/13 www.te.com/enterprise-asia
203
Modular Twisted Pair
Category 7A - Cable
Category 7A S/FTP Cable AWG 22
FEATURES
• High performance S/FTP cable
• Enables broadband applications like CATV, multimedia etc.
• Qualified against IEC 61156-7 and tested up to 1500MHz
• Individually foiled pairs plus overall copper braid
• AWG 22 solid conductor
• Fire retardant LSZH sheath
Color: white
ORDERING INFORMATION
Description
Part Number
AWG 22; Type: Simplex; OD 8.1 mm; Packaging: 1000 m/Reel
1499101-1
AWG 22; Type: Duplex; OD 8.1 x 16.5 mm; Packaging: 500 m/Reel
1711003-1
Category 7A S/FTP Cable AWG 23
FEATURES
• High performance S/FTP cable
12. Modular Twisted Pair Cabling
• Qualified against IEC 61156-5 Category 7A and tested up to 1200MHz
• Individually foiled pairs plus overall copper braid
• AWG 23 solid conductor
• Fire retardant LSZH sheath
Color: white
ORDERING INFORMATION
Description
Part Number
AWG 23; Type: Simplex; OD 7.9 mm; Packaging: 1000 m/Reel
1711910-1
AWG 23; Type: Duplex; OD 7.9 x 16.0 mm; Packaging: 500 m/Reel
1711913-1
204
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 7A - Jacks
AMP-TWIST 7AS SL Jack
FEATURES
• 4 chamber connector, fully compatible to IEC 61076-3-104 Ed. 2, 1000 MHz
• Class FA / Category 7A as per ISO/IEC 11801 Ed.2 Amd.2
• Termination time less than 1.5 minutes using TE’s AWC technique
• Easiest installation with only 2 parts
• Patented shield clamp with integrated strain relief
• Available with or without dust cover
• Optional colored dust covers available
ORDERING INFORMATION
Description
Part Number
Cat. 7A die-cast Jack without dust cover, 180° cable exit
1711437-1
1711441-1
Colored dust cover (in bag of 50 pieces); Color: blue
1-1711481-6
Colored dust cover (in bag of 50 pieces); Color: red
1-1711481-7
Colored dust cover (in bag of 50 pieces); Color: yellow
1-1711481-8
Colored dust cover (in bag of 50 pieces); Color: green
1-1711481-9
12. Modular Twisted Pair Cabling
Cat. 7A die-cast Jack with dust cover, 180° cable exit
318108AE 12/13 www.te.com/enterprise-asia
205
Modular Twisted Pair
Category 7A - Consolidation Point
AMP-TWIST 7AS Consolidation Point Transition Cable Assemblies
FEATURES
• Assembly to connect the work area outlet with the consolidation
or transition point
• Saves time and money on moves, adds and changes
• Slim line design for High-Density solutions
• According to ISO/IEC 11801
• Cat. 7A S/FTP solid cable acc. to IEC 61156-7
• LSFRZH sheath
Color: white
ORDERING INFORMATION
Description
Part Number
AMP-TWIST 7AS SL jack w/o dust cover to
AMP-TWIST 7AS plug; Class FA
Y-1711579-X
AMP-TWIST 7AS SL jack with dust cover to
AMP-TWIST 7AS plug; Class FA
Y-1711776-X
Other lengths on request.
12. Modular Twisted Pair Cabling
206
www.te.com/enterprise-asia 12/13 318108AE
Y- -X
Length
0- -5
5.0 m
1- -4
7.5 m
1- -0
10.0 m
1- -5
15.0 m
2- -0
20.0 m
3- -0
30.0 m
Modular Twisted Pair
Category 7A - Patch Cords
AMP-TWIST 7AS to AMP-TWIST 7AS Patch Cord
FEATURES
• Slim line design for High-Density solutions
• Category 7A S/FTP stranded cable
• LSZH sheath
• Black boot on AMP-TWIST 7AS plug
Color: white
ORDERING INFORMATION
Y- -X
Length
0.5 m
Description
Part Number
1- -1
Pairs: 4; Cat. 7A
Y-1711637-X
0- -1
1.0 m
0- -2
2.0 m
0- -3
3.0 m
Other lengths on request.
0- -5
5.0 m
1- -0
10.0 m
Y- -X
Length
1- -1
0.5 m
Part Number
0- -1
1.0 m
Y-336488-X
0- -2
2.0 m
0- -3
3.0 m
0- -5
5.0 m
1- -0
10.0 m
AMP-TWIST 7AS to RJ-45 Patch Cord
12. Modular Twisted Pair Cabling
FEATURES
• Slim line design for High-Density solutions
• Category 7 S/FTP stranded cable
• LSZH sheath
• Black boot on AMP-TWIST 7AS plug
Color: white
ORDERING INFORMATION
Description
Pairs: 4; Cat. 6A
Other lengths on request.
318108AE 12/13 www.te.com/enterprise-asia
207
Modular Twisted Pair
Category 7A - Patch Cords
AMP-TWIST 7AS (2 Pair) to RJ-45 Patch Cord
FEATURES
• Slim line design for High-Density solutions
• Stranded shielded cable
• LSZH sheath
• Black boot on AMP-TWIST 7AS plug
Color: white
ORDERING INFORMATION
Y- -X
Length
1- -1
0.5 m
0- -1
1.0 m
0- -2
2.0 m
Description
Part Number
0- -3
3.0 m
Pairs: 2 (Ethernet 12/36); Cat. 5E
Y-1711613-X
0- -5
5.0 m
Pairs: 2 (ISDN 36/45); Cat. 5E
Y-1711618-X
1- -0
10.0 m
Y- -X
Length
1- -1
0.5 m
0- -1
1.0 m
0- -2
2.0 m
3.0 m
Other lengths on request.
AMP-TWIST 7AS Telephone Patch Cord (1 Pair)
FEATURES
• Slim line design for High-Density solutions
• RJ-11 to 1pair plug acc. to IEC 61076-3-104
12. Modular Twisted Pair Cabling
• LSZH sheath
• Black boot
Color: black
ORDERING INFORMATION
Description
Part Number
0- -3
Pairs: 1 (Voice Application); Cat. 3
Y-1711623-X
0- -5
5.0 m
1- -0
10.0 m
Other lengths on request.
208
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 7A - Patch Cords
AMP-TWIST 7AS CATV Patch Cord (1 Pair)
FEATURES
• Slim line design for High-Density solutions
• PAL or male F-Series connector with integrated balun
to 1 pair plug acc. to IEC 61076-3-104
• Category 7A S/FTP stranded cable
• LSZH sheath
• Black boot
Color: green
ORDERING INFORMATION
Y- -X
Length
1- -1
0.5 m
0- -1
1.0 m
0- -2
2.0 m
Description
Part Number
0- -3
3.0 m
Pairs: 1 (F-conn with Balun); CATV
Y-1711624-X
0- -5
5.0 m
Pairs: 1 (Coax with Balun); CATV
Y-1711659-X
1- -0
10.0 m
Y- -X
Length
0- -5
5.0 m
1- -4
7.5 m
Other lengths on request.
FEATURES
• Slim line design for High-Density solutions
• Category 7A S/FTP cable
• LSZH sheath
• Black boot on AMP-TWIST 7AS plug
Color: white
ORDERING INFORMATION
Description
Part Number
1- -0
10.0 m
Pairs: 4; Cat. 7A; Construction: Stranded
Y-1711580-X
1- -5
15.0 m
Pairs: 4; Cat. 7A; Construction: Solid
Y-1711787-X
2- -0
20.0 m
3- -0
30.0 m
Other lengths on request.
318108AE 12/13 www.te.com/enterprise-asia
209
12. Modular Twisted Pair Cabling
AMP-TWIST 7AS Single End Patch Cord
Modular Twisted Pair
Category 7A - Patch Cords
Category 7A ARJ-45 Patch Cord
FEATURES
• Ideal for installations in combination with AMP CO Plus ARJ-45 Cat. 7A
• Category 7A S/FTP stranded cable
• ARJ-45 plug acc. to IEC 60603-7-7
• LSZH sheath
Color: white
ORDERING INFORMATION
Y- -X
Length
0- -1
1.0 m
0- -2
2.0 m
Description
Part Number
0- -3
3.0 m
ARJ-45 to ARJ-45; Cat. 7A
Y-1711563-X
0- -5
5.0 m
ARJ-45 to RJ-45; Cat. 6A
Y-1711564-X
1- -0
10.0 m
12. Modular Twisted Pair Cabling
210
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6A - Cable
Category 7 S/FTP Cable
FEATURES
• Qualified against IEC 61156-5 Category 7 and EN 50288-4-1
• Individually foiled pairs plus overall copper braid
• AWG 23 solid conductor
• Fire retardant LSZH sheath
Color: white
ORDERING INFORMATION
Description
Part Number
AWG 23; Type: Simplex; OD: 7.3 mm; Packaging: 1000 m/Reel
57893-1
AWG 23; Type: Duplex; OD: 7.6 x 16.0 mm; Packaging: 500 m/Reel
1711005-1
Category 7 F/FTP Cable
FEATURES
• Qualified against IEC 61156-5 Category 7 and EN 50288-4-1
• Individually foiled pairs plus overall foil shield and drain wire
• AWG 23 solid conductor
12. Modular Twisted Pair Cabling
• LSZH sheath
Color: white
ORDERING INFORMATION
Description
Part Number
AWG 23; Type: Simplex; OD: 7.4 mm; Packaging: 500 m/Reel
1711163-1
AWG 23; Type: Duplex; OD: 7.2 x 15.0 mm; Packaging: 500 m/Reel
1711195-1
Category 7 S/FTP Outdoor Cable
FEATURES
• Qualified against IEC 61156-5 Category 7 and EN 50288-4-1
and tested up to 600MHz
• Suitable for 10GBase-T applications
• Can be used for direct burial and cable duct installation
• Individually foiled pairs plus overall copper braid
• Double jacketed:
• Inner jacket material: LSZH
• Outer jacket material: PE black, UV resistant
• Moisture barrier (plastic coated aluminum tape) in between jackets
• AWG 23 solid conductor
Color: black
ORDERING INFORMATION
Description
Part Number
AWG 23; Type: Simplex; OD 11.7 mm; Packaging: 1000 m/Reel
2153161-1
318108AE 12/13 www.te.com/enterprise-asia
211
Modular Twisted Pair
Category 6A - Cable
640 Series Category 6A F/UTP Twisted Pair Cable
FEATURES
• Qualified against TIA-568-C.2 Category 6A
and ISO/IEC 11801:2002 Class EA
• Suitable for 10GBase-T applications
• Overall foil shield, embedded in between synthetic tapes, with drain wire
• AWG 23 solid conductor
• RoHS compliant
ORDERING INFORMATION
Rating
Pairs
OD(mm)
AWG
Part Number
LSZH
TE640Z1F-XXYY-AP
LSFRZH
4
CM
7.9
TE640Z3F-XXYY-AP
23
TE640MF-XXYY-AP
CMR
TE640RF-XXYY-AP
640 Series Catalog 6A U/UTP Twisted Pair Cable
FEATURES
• Supports 10Gigabit Ethernet to a full 100m up to 500MHz
• UTP cable, qualified against TIA-568-C Category 6A
12. Modular Twisted Pair Cabling
• “H” type filler and dual jacket to minimise the effect of alien crosstalk
• AWG 23 solid conductor
• LSZH sheath acc. to IEC 60332-1 fire rating
Color: blue
ORDERING INFORMATION
Rating
Pairs
OD(mm)
AWG
LSZH
4
7.4*8.1
23
Part Number
TE640Z1-XXYY-AP
The following colors are available:
The following package is available:
Replace “XX” with:
Replace “YY” with:
BL = Blue WT = White GY = Gray YL = Yellow VT = Violet
M2 = 305m reel M3 = 500m reel
GN = Green RD = Red OR = Orange BK = Black
212
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6A - Jacks
AMP-TWIST 6AS SL Jack
FEATURES
• Class EA / Category 6A as per ISO/IEC 11801 Ed.2 Amd.2
• Termination time less than 1 minute using TE’s AWC technique
• Easiest installation with only 2 parts
• Patented shield clamp with integrated strain relief
• Available with or without dust cover
• Optional colored dust covers available
ORDERING INFORMATION
Description
Part Number
Cat. 6A RJ-45 die-cast Jack without dust cover, 180° cable exit
Cat. 6A RJ-45 die-cast Jack with dust cover, 180° cable exit
1711716-1
1711592-1
Colored dust cover (bag of 50 pieces); Color: blue
1-1711691-6
Colored dust cover (bag of 50 pieces); Color: red
1-1711691-7
Colored dust cover (bag of 50 pieces); Color: yellow
1-1711691-8
Colored dust cover (bag of 50 pieces); Color: green
1-1711691-9
12. Modular Twisted Pair Cabling
RJ45 STP KM8 Modular Jacks
FEATURES
• Class EA / Category 6A as per ISO/IEC 11801 Ed.2 Amd.2
• Keystone design ensures compatibility with a range of faceplates
and adaptors
• KM8® design provide built-in conductor management
• LSA-PLUS quick connection technique with highly reliable wire
termination method
• Shielding clamp ensures full 360º bonding and grounding
• Universal wiring - T568 A or B wiring pattern
ORDERING INFORMATION
Description
Part Number
Cat. 6A RJ-45 shielded Jack without dust cover; Color: white (RAL 9010)
6830 1 811-01
Cat. 6A RJ-45 shielded Jack without dust cover; Color: black (RAL 9005)
6830 1 811-04
318108AE 12/13 www.te.com/enterprise-asia
213
Modular Twisted Pair
Category 6A - Jacks
Q- Jack (STP)
FEATURES
• Class EA / Category 6A as per ISO/IEC 11801 Ed.2 Amd.2
• Suitable for Q-Jack Patch Panels (Page 247)
• Punch down termination onto LSA-PLUS contacts to ensure swift installation
• Shielded cap ensures full 360º bonding and grounding
• Universal wiring - T568 A or B wiring pattern
ORDERING INFORMATION
Description
Part Number
Cat. 6A RJ-45 shielded Jack without dust cover (blister
pack of 12 units); Color: black (RAL 9005)
300001743975
Q- Jack (UTP)
FEATURES
• Class EA / Category 6A as per ISO/IEC 11801 Ed.2 Amd.2
• Suitable for Q-Jack Patch Panels (Page 247)
• Punch down termination onto LSA-PLUS contacts to ensure swift installation
• Universal wiring - T568 A or B wiring pattern
ORDERING INFORMATION
12. Modular Twisted Pair Cabling
Description
Part Number
Cat. 6A RJ-45 unshielded Jack without dust cover (blister
pack of 12 units); Color: black (RAL 9005)
300001743978
RJ45 UTP Modular Jack
FEATURES
• Class EA / Category 6A as per ISO/IEC 11801 Ed.2 Amd.2
• Keystone design ensures compatibility with a range of faceplates
and adaptors
• Punch down termination onto LSA-PLUS contacts to ensure
swift installation
• Carbon cap to mitigate alien crosstalk
• Universal wiring - T568 A or B wiring pattern
ORDERING INFORMATION
Description
Part Number
Cat. 6A RJ-45 unshielded Jack without dust cover; Color: white (RAL 9010)
6830 1 885-01
Cat. 6A RJ-45 unshielded Jack without dust cover; Color: black (RAL 9005)
6830 1 885-04
214
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6A - Jacks / Patch Panels
Category 6A U/UTP AMP-TWIST Modular Jack
FEATURES
• Class EA as per ISO/IEC 11801 Ed.2 Amd.2
• Termination time less than 1 minute using TE’s AWC technique
• Easiest installation with only 2 parts
• Superior technology to reduce alien crosstalk
• Available with or without dust cover
• UL listed
• Several colors available on demand
X
Color
-1
Almond
-2
Black
-4
Gray
-5
Orange
-6
Blue
Part Number
-7
Red
Cat. 6A RJ-45 unshielded Jack without dust cover, 180° cable exit
1933476-X
-8
Yellow
Cat. 6A RJ-45 unshielded Jack with dust cover, 180° cable exit
2111676-X
-9
Green
ORDERING INFORMATION
Description
XG Category 6A AMP-TWIST Shielded Patch Panels
FEATURES
• Meets or exceeds all IS0/IEC Category 6A performance standards
• Shielded installation made simple with jacks
• Ports may be individually replaced
• Packaged unloaded with jacks bagged separately for
termination with SL Series Jack Termination Tool
A
• Available in straight and angled versions
• Labels and label covers included
• Accommodates icons (sold separately)
• Integrated bonding bar makes bonding
simple and requires no extra steps
B
Color : black
ORDERING INFORMATION
Description
Height
Width
Figure
Part Number
24-Port Straight Panel
1U (1.75")
19.0"
–
1933319-2
48-Port Straight Panel
2U (3.50")
19.0"
A
1933320-2
24-Port Angled Panel
1U (1.75")
19.0"
–
1933321-2
48-Port Angled Panel
2U (3.50")
19.0"
B
1933322-2
318108AE 12/13 www.te.com/enterprise-asia
215
12. Modular Twisted Pair Cabling
• Universal wiring - T568 A or B wiring pattern
Modular Twisted Pair
Category 6A - Consolidation Point
AMP-TWIST 6AS Consolidation Point Transition Cable Assemblies
FEATURES
• Assembly to connect the work area outlet with the consolidation
or transition point
• Saves time and money on moves, adds and changes
• According to ISO/IEC 11801
• Category 7 F/FTP solid cable according to IEC 61156-5 and EN 50288-4-1
• LSZH sheath
• Universal wiring Color: white
ORDERING INFORMATION
Y- -X
Length
0- -5
5.0 m
1- -4
7.5 m
Description
Part Number
1- -0
10.0 m
AMP-TWIST 6AS SL jack w/o dust cover to RJ-45 plug; Class EA,
Y-1711825-X
1- -5
15.0 m
AMP-TWIST 6AS SL jack with dust cover to RJ-45 plug; Class EA
Y-1711851-X
2- -0
20.0 m
3- -0
30.0 m
12. Modular Twisted Pair Cabling
Category 6A F/UTP Solid Consolidation Cords
FEATURES:
• Meets Category 6A performance standard
Y-X
Length
• Category 6A F/UTP solid cable
1- -0
10.0 m
• LSZH sheath
1- -2
12.0 m
1- -4
14.0 m
2- -0
20.0 m
3- -0
30.0 m
• Color-matched snagless boots
• Patch cord RJ-45 to RJ-45 Category 6A
Color: White
Other lengths on request!
ORDERING INFORMATION
Description
Part Number
Category 6A F/UTP Solid Consolidation Cords
Y-1859352-X
216
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6A - Patch Cords
Category 6A S/FTP Patch Cord RJ-45 LSZH
FEATURES
• Category 7 S/FTP stranded cable
• LSZH sheath
• Color-matched snagless boots
ORDERING INFORMATION
Description
Part Number
Color: white
Y-1711815-X
Color: blue
Y-1711816-X
Color: gray
Y-1711817-X
Color: yellow
Y-1711818-X
Color: red
Y-1711819-X
Color: green
Y-1711820-X
Y- -X
Length
1- -1
0.5 m
0- -1
1.0 m
0- -2
2.0 m
0- -3
3.0 m
0- -5
5.0 m
1- -0
10.0 m
Other colors and lengths are available upon request.
FEATURES
• Meets or exceeds the channel specification of TIA-568-C.2 Category 6A
shielded and Amendment 1 to ISO11801:2002 Class EA up to 500MHz
• Meets or exceeds all requirements for IEEE 802.3an 10GbE
• Transparent, flexible SL boot
• 4-Pair stranded shielded cable
• LSZH cable jacket
• RoHS compliant
ORDERING INFORMATION
Description
Part Number
Y- -X
Length
White
Y-1859517-X
0- -1
1.0 m
Blue
Y-1859514-X
0- -2
2.0 m
Gray
Y-1859513-X
0- -3
3.0 m
Yellow
Y-1859518-X
0- -5
5.0 m
Red
Y-1859516-X
1- -0
10.0 m
Other colors on request
318108AE 12/13 www.te.com/enterprise-asia
217
12. Modular Twisted Pair Cabling
Category 6A F/UTP Patch Cord RJ45 LSZH
Modular Twisted Pair
Category 6A - Patch Cords
Category 6A F/UTP Patch Cord RJ45 CM
FEATURES
• Meets or exceeds the channel specification of TIA-568-C.2 Category 6A
shielded and Amendment 1 to ISO11801:2002 Class EA up to 500MHz
• Meets or exceeds all requirements for IEEE 802.3an 10GbE
• Transparent, flexible SL boot
• 4-Pair stranded shielded cable
• FRPVC CM cable jacket
• RoHS compliant
ORDERING INFORMATION
Description
Part Number
Y- -X
Length
White
Y-1933885-X
0- -1
1ft
Blue
Y-1933882-X
0- -4
4ft
Gray
Y-1933881-X
0- -7
7ft
Yellow
Y-1933886-X
1- -0
10ft
Red
Y-1933884-X
1- -5
15ft
Other colors on request
Other lengths on request
12. Modular Twisted Pair Cabling
Category 6A U/UTP Patch Cord RJ45 CM
FEATURES
• Meets or exceeds the channel specifications of ANSI/
TIA-568-C.2 Category 6A and Amendment 1 to ISO/
IEC 11801:2002 Class EA up to 500 MHz
• Patented technology to minimize the effects
of alien crosstalk and insertion loss
• Supports 10 Gigabit Ethernet over unshielded
copper to a full 100m up to 500MHz
• Stranded copper conductors in the cable pairs
• Flexible strain relief boot
• UL 1863 listed
ORDERING INFORMATION
Description
Part Number
RJ45 to RJ45 T568B patch cord
6645-2-8X5-YY
RJ45 to RJ45 T568A patch cord
6645-2-8X0-YY
The following colors are available:
Length
04
4ft
07
7ft
10
10ft
15
15ft
25
25ft
50
50ft
Other lengths on request
Replace X for color:
0 = White3 = Yellow
1 = Red4 = Green
2 = Blue6 = Gray
Other colors on request
218
YY
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6A - HighBand
HighBand® Solution
TE Connectivity HighBand® cross connect solution allows for maximum network throughput beyond
ten Gigabit. It is the platform needed for the most advanced networks.
The HighBand® solution consists of high performance disconnection modules, user friendly cable
management and innovative anti-snag patch cords. It is the ideal cabling solution for companies that
are conscious of efficiency, guaranteed performance and appealing aesthetics.
Modules can be either patched or jumpered and used in a Patch-by-Exception structured cabling
solution. Patch-by-Exception solutions offer material, installation and operational cost savings over
traditional RJ45 products. In all newly installed PBE systems there are no patch cords or jumper
cables visible to the front. The system is totally hard wired from network equipment to work area,
providing a secure, reliable, high performance infrastructure from switch to work area, or PABX to
telephone.
HighBand® utilises the silver plated, world renowned LSA-PLUS® contact principle. This technology
has become the industry standard in over 140 countries. The gas tight contacts ensure a reliable
and long lasting connection. The frequent moves, adds and changes that occur in today’s cabling
systems can quickly degrade the quality of wire termination. TE Connectivity products maintain
superior connectivity during hundreds of re-terminations and deliver the best electrical performance
in the industry.
12. Modular Twisted Pair Cabling
FEATURES AND BENEFITS
• Unrivalled maximum headroom above
Category 6A standards
• T
he world’s only Category 6A disconnect
module providing unique Patch-by-Exception
functionality and improved administration
• Modules can be jumpered or patched (or both)
• A
test port provides “look-both-ways” testing capability
without the removal of any wires; also allows simple
circuit monitoring through use of a test cord
• Integrates easily with all of TE Connectivity's solutions
• S
ilver plated LSA-PLUS® contacts made
from superior spring copper alloy
• U
pper and lower shell mouldings made from
high quality PBT plastic
• A
vailable as individual components or in complete
systems, consisting of unique disconnect
modules, cable managers, covers, patch cords,
mounting frames and label holders
318108AE 12/13 www.te.com/enterprise-asia
219
Modular Twisted Pair
Category 6A - HighBand
Module Specifications
MECHANICAL
Wire Range for solid and stranded copper conductors:
0.4mm to 0.65mm (26 to 22 AWG)*
Wire insulation diameter range (PE,PVC):
0.7mm to 1.4mm
Number of wire terminations:
≥200
Wire insertion force (0.5mm conductor dia): 6N
Wire pull out force, radial (0.5mm conductor dia):
≥5N
Wire pull out force, axial (0.5mm conductor dia):
≥35N
Number of patching cycles:750
*A maximum of 2 equal diameter solid conductors only, of up to 0.5mm conductor diameter can be
terminated per slot. Only 1 conductor of stranded wires per slot can be terminated. If any conductors
>0.5mm diameter have been terminated, reversal to smaller conductors is no longer possible.
12. Modular Twisted Pair Cabling
ELECTRICAL
Transmission, performance and reliability:
Voltage rating:
Insulation resistance:
Exceeds ISO/IEC 11801
AS/NZS 3080
TIA/EIA 568-B
150 VAC
≥500,000 MΩ at 500 VDC
ENVIRONMENTAL AND SAFETY
Safety Compliance:
Flammability rating of plastic housing:
Environment for use:
Operating temperature range:
Maximum relative humidity:
UL 1863
UL 94 VO
Indoors or in dry enclosure rated IP54 or greater
-40°C to +80°C
≤93% non-condensing
Dimensions of an installed 20-pair system with dual and single cable management on either side.
220
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6A - HighBand
3
2.2
2.3
2.4
2
2.1
1.1
1.3
12. Modular Twisted Pair Cabling
1.2
1
4
KEY
1
Cable Management Kit
1.1 Vertical Cable Manager (2)
1.2 Cover (1)
1.3 Bi-directional hinged clips (4)
2
HighBand® Module Kit
2.1 12-way wall mount Frame (1)
2.2 Rear Cable Manager (12)
2.3 HighBand Module (12)
2.4 Label Holder Kit (12)
3
Cable Trough, top
4
Cable Trough, bottom
318108AE 12/13 www.te.com/enterprise-asia
221
Modular Twisted Pair
Category 6A - HighBand
HighBand® 12-way Kit
The HighBand® Module allows for the termination of
4-pair UTP cables. HighBand® technology enables the
highest performing Category 6A modules in the world
with transmission performance headroom far exceeding
all local and International standards.
6
A
HighBand 12-way Kit
ORDERING INFORMATION
Description
Quantity
Part Number
HighBand 12-way Kit
12. Modular Twisted Pair Cabling
Consists of (1) wall mount frame, (12) 20-pair HighBand Category 6A
modules including rear cable manager and (12) label holders.
Kit
6450 1 107-01
HighBand® Consolidation Point Kit,100-pair
For use in horizontal cabling as a high-density
consolidation point, ideal for use inside a ceiling or
false floor. The modules clip directly on to the specially
designed metal backmount frame. The metal cover clips
into place to protect the modules from dust and foreign
particles.
HighBand Consolidation Point Kit 100-pair
ORDERING INFORMATION
Description
Quantity
Part Number
HighBand Consolidation Point Kit, 100-pair
Consists of (5) 20-pair HighBand Category 6A modules, (5) label
holders, (1) wall mount frame and (1) protective cover.
222
Kit
www.te.com/enterprise-asia 12/13 318108AE
6450 1 105-21
Modular Twisted Pair
Category 6A - HighBand
HighBand® 20-pair Module with rear cable manager
The 20-pair module is the world’s highest
performing cross-connect module.
It is designed to suit 5 incoming and 5 outgoing
4-pair Category 6A cables. Each IDC slot is
colour coded to allow for accurate termination
of each of the 4 pairs. The module utilises a
disconnect feature making it ideal for
Patch-by-Exception installations and can also be
patched as a traditional cross-connect. The cable
manager at the rear of the module ensures that
cables are held in place securely without the
need for Velcro ties.
HighBand 20-pair Module with rear cable
manager
Description
Quantity
Part Number
HighBand 20-pair Module with rear cable manager
Box of 12
6468 5 700-10
12. Modular Twisted Pair Cabling
ORDERING INFORMATION
8-pair Module
Used to terminate two 4-pair cables, these modules
provide the highest performing method of cross-connect
of any product on the market.
8-pair Module
ORDERING INFORMATION
Description
Quantity
Part Number
8-pair Module
Box of 10
6468 5 070-00
Each
6036 2 005-02
Hinged Label Holder
318108AE 12/13 www.te.com/enterprise-asia
223
Modular Twisted Pair
Category 6A - HighBand
HighBand® Cable Management
The cable management rings control vertical cable management between frames, ensuring
that cables do not interfere when adds, moves and changes occur. The dual cable manager
is ideal for high density or heavily patched installations and provides a neat, clean finish to
the HighBand® system. The single cable manager is best suited to either the start or finish
of the system.
Cable troughs mounted on the top and bottom of each frame ensure superior patch cord
management and correct bend radius between frames.
Top Cable Trough
Cable
Management
12. Modular Twisted Pair Cabling
Rings
Bottom Cable Trough
Vertical
Management Cover
ORDERING INFORMATION
Description
Quantity
HighBand 12-way Cable Management Kit
Part Number
Kit
6450 1 103-10
Kit
6450 1 104-10
Cable Management Rings
Bag of 2
6450 2 156-20
HighBand Cover
Box of 1
6450 2 158-20
HighBand Cable Trough, Top
Box of 1
6450 2 157-10
HighBand Cable Trough, bottom
Box of 1
6450 2 157-20
Includes (2) cable management rings and (1) cover
HighBand 36-way Cable Management Kit
Includes (6) cable management rings and (3) covers
224
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6A - HighBand
HighBand® Patch Cords
These patch cords are used for patching all four pairs
between Category 6A modules. Spring loaded shutter
protects the contacts when not in use.
Rear Facing Patch Cord
These patch cords can be used in TE Connectivity's
HighBand® Patch-by-Exception solutions to break
the original circuit and patch to a new location.
Front Facing Patch Cord
ORDERING INFORMATION
Quantity
Length
Colour
4-pair Rear Facing to RJ45 Patch Cord
Bag of 1
1.2m
Blue
6451 2 400C-10
4-pair Rear Facing to RJ45 Patch Cord
Bag of 1
2.1m
Blue
6451 2 400C-20
4-pair Rear Facing to RJ45 Patch Cord
Bag of 1
3.0m
Blue
6451 2 400C-30
4-pair Rear Facing to RJ45 Patch Cord
Bag of 1
4.5m
Blue
6451 2 400C-40
4-pair Rear Facing Patch Cord
Bag of 1
1.2m
Blue
6451 2 401C-10
4-pair Rear Facing Patch Cord
Bag of 1
2.1m
Blue
6451 2 401C-20
4-pair Rear Facing Patch Cord
Bag of 1
3.0m
Blue
6451 2 401C-30
4-pair Rear Facing Patch Cord
Bag of 1
4.5m
Blue
6451 2 401C-40
4-pair Front Facing Patch Cord
Bag of 1
1.2m
Blue
6451 2 403C-10
4-pair Front Facing Patch Cord
Bag of 1
2.1m
Blue
6451 2 403C-20
4-pair Front Facing Patch Cord
Bag of 1
3.0m
Blue
6451 2 403C-30
4-pair Front Facing Patch Cord
Bag of 1
4.5m
Blue
6451 2 403C-40
4-pair Front Facing to RJ45 Patch Cord
Bag of 1
1.2m
Blue
6451 2 404C-10
4-pair Front Facing to RJ45 Patch Cord
Bag of 1
2.1m
Blue
6451 2 404C-20
4-pair Front Facing to RJ45 Patch Cord
Bag of 1
3.0m
Blue
6451 2 404C-30
4-pair Front Facing to RJ45 Patch Cord
Bag of 1
4.5m
Blue
6451 2 404C-40
318108AE 12/13 www.te.com/enterprise-asia
Part Number
225
12. Modular Twisted Pair Cabling
Description
Modular Twisted Pair
Category 6 - Cable
Category 6 F/FTP Cable
FEATURES
• Qualified against IEC 61156-5 Category 6 and EN 50288-5-1
• Individually foiled pairs plus overall foil shield
• AWG 23 solid conductor
• LSZH sheath
ORDERING INFORMATION
Description
Color
Part Number
AWG 23; Type: Simplex; OD: 7.3 mm; Packaging: 500 m/Reel
White
1711007-1
AWG 23; Type: Duplex; OD: 7.6 x 15.5 mm; Packaging: 500 m/Reel
White
1711008-1
620 Series Category 6 U/UTP Twisted Pair Cable
FEATURES
• Meets or exceeds the cable specifications of TIA-568-C.2
Category 6 and ISO11801:2002 Class E up to 300MHz
• 3dB NEXT performance above Category 6
• Cross web filler to separate the pairs
• AWG23 solid conductor
• Exceeds all requirements for Gigabit Ethernet
12. Modular Twisted Pair Cabling
The following colors are available:
• RoHS Compliant
Replace “XX” with:
ORDERING INFORMATION
BL = Blue WT = White GY = Gray YL = Yellow
GN = Green RD = Red OR = Orange BK = Black
Rating
Pairs
OD(mm)
AWG
LSZH
4
6.4
23
Part Number
TE620R-XXYY-AP
The following package is available:
Replace “YY” with:
RB = 1000FT reel-in-box
610 Series Category 6 F/UTP Twisted Pair Cable
FEATURES
• Meets or exceeds the cable specifications of TIA568-C.2 Category 6 and ISO11801:2002 Class E
• Overall foil shield with drain wire
• Cross web filler to separate the pairs
• AWG23 solid conductor
• Exceeds all requirements for Gigabit Ethernet
• RoHS Compliant
ORDERING INFORMATION
The following colors are available:
Replace “XX” with:
Pairs
OD(mm)
AWG
CM
4
7.2
23
TE610MF-XXYY-AP
LSZH
4
7.2
23
TE610Z1F-XXYY-AP
Replace “YY” with:
LSFRZH
4
7.2
23
TE610Z3F-XXYY-AP
M2 = 305m reel M3 = 500m reel M6 = 1000m reel
226
Part Number
BL = Blue WT = White GY = Gray YL = Yellow
Rating
GN = Green RD = Red OR = Orange BK = Black
The following package is available:
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6 - Cable
610 Series Category 6 U/UTP Twisted Pair Cable
FEATURES
• Meets or exceeds the cable specifications of TIA568-C.2 Category 6 and ISO11801:2002 Class E
• Cross web filler to separate the pairs
• Exceeds all requirements for Gigabit Ethernet
• RoHS Compliant
ORDERING INFORMATION
Rating
Pairs
OD(mm)
AWG
CM
4
5.6
24
TE61024M-XXYY-AP
Part Number
CMR
4
5.6
24
TE61024R-XXYY-AP
LSZH
4
5.6
24
TE61024Z1-XXYY-AP
CM
4
6.4
23
TE610M-XXYY-AP
LSZH
4
6.4
23
TE610Z1-XXYY-AP
Replace “YY” with:
LSFRZH
4
6.4
23
TE610Z3-XXYY-AP
MB-305m reel-in-box
The following colors are available:
Replace “XX” with:
BL = Blue WT = White GY = Gray YL = Yellow
GN = Green RD = Red OR = Orange BK = Black
The following package is available:
Category 6 U/UTP Outdoor Cable
FEATURES
12. Modular Twisted Pair Cabling
• 250 MHz Category. 6 U/UTP Cable
• Black PE jacket
• AWG 23 solid conductor
• For outdoor use, UV resistance
ORDERING INFORMATION
Description
Part Number
Sheathing: PE; OD: 6.0 mm; Packaging: 305m/reel in box
1427319-1
318108AE 12/13 www.te.com/enterprise-asia
227
Modular Twisted Pair
Category 6 - Jacks
AMP-TWIST 6S SL Jack
FEATURES
• Category 6 as per ISO/IEC 11801 Ed.2 Amd.2
• Class EA as per ISO/IEC 11801 Ed.2 Amd.1
• Termination time less than 1 minute
using TE’s AWC technique
• Easiest installation with only 2 parts
• Patented shield clamp with integrated strain relief
• Available with or without dust cover
• Available with rear (180°) or side (90°) cable exit
• Available DIN Rail Kit
• Optional colored dust covers available
ORDERING INFORMATION
Description
Part Number
Cat. 6 RJ-45 die-cast Jack without dust cover, 180° cable exit
1711342-2
Cat. 6 RJ-45 die-cast Jack without dust cover, 90° cable
1711343-2
Cat. 6 RJ-45 die-cast Jack with dust cover, 180° cable exit
1711160-2
Cat. 6 RJ-45 die-cast Jack with dust cover, 90° cable exit
1711295-2
12. Modular Twisted Pair Cabling
Colored dust cover (bag of 50 pieces); Color: blue
1-1711691-6
Colored dust cover (bag of 50 pieces); Color: red
1-1711691-7
Colored dust cover (bag of 50 pieces); Color: yellow
1-1711691-8
Colored dust cover (bag of 50 pieces); Color: green
1-1711691-9
RJ45 STP KM8® Modular Jack
FEATURES
• Class E / Category 6 as per ISO/IEC 11801 Ed.2 Amd.2
• Keystone design ensures compatibility with
a range of faceplates and adaptors
• KM8® design provide built-in conductor management
• LSA-PLUS quick connection technique with
highly reliable wire termination method
• Shielding clamp ensures full 360° bonding and grounding
• Universal wiring - T568 A or B wiring pattern
ORDERING INFORMATION
Description
Part Number
Cat. 6 RJ-45 Shielded Jack without dust cover;
Color: white (RAL 9010)
6830 1 810-01
Cat. 6 RJ-45 Shielded Jack without dust cover;
Color: black (RAL 9005)
6830 1 810-04
228
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6 - Jacks
SL Series 110Connect Jacks (STP)
FEATURES
• Category 6 Pyramid Tested
• Universal wiring - T568 A or B wiring pattern
ORDERING INFORMATION
Description
Part Number
Cat. 6 RJ-45 shielded Jack without dust cover, 180° cable exit
1375188-1
SL Series 110Connect Jacks (UTP)
FEATURES
• SlimLine (SL) Series: Thin profile improves outlet density
• Category 6 Pyramid Tested
• Available with or without dust cover
• 90° or 180° cable dress for easy termination
• Bend-limiting strain relief included
• Universal wiring - T568 A or B wiring pattern
• Several colors available on demand
ORDERING INFORMATION
Y- -X
Color
0- -1
Beige
0- -2
Black
Description
Part Number
0- -3
White
Cat. 6 RJ-45 unshielded Jack without dust cover
Y-1933748-X
0- -6
Blue
Cat. 6 RJ-45 unshielded Jack with dust cover
Y-1375187-X
0- -7
Red
Cat. 6 RJ-45 unshielded Jack with dust cover (for Korean market only)
1375055-X
318108AE 12/13 www.te.com/enterprise-asia
229
12. Modular Twisted Pair Cabling
• UL listed
Modular Twisted Pair
Category 6 - Jacks
RJ45 UTP KM8® Modular Jack
FEATURES
• Class E / Category 6 as per ISO/IEC 11801 Ed.2 Amd.2
• Keystone design ensures compatibility with a range of faceplates and adaptors
• KM8® design provide built-in conductor management
• LSA-PLUS quick connection technique with highly reliable wire
termination method
• Universal wiring - T568 A or B wiring pattern
• Several colors available on demand
ORDERING INFORMATION
Description
Part Number
Cat. 6 RJ-45 Unshielded Jack without dust cover; Color: white (RAL 9010)
6830 1 800-01
Cat. 6 RJ-45 Unshielded Jack without dust cover; Color: black (RAL 9005)
6830 1 800-04
SL Series Modular Coupler
FEATURES
• Straight Category 6 coupler
12. Modular Twisted Pair Cabling
• Compact coupler for two modular plugs
• SL Series: Thin profile improves outlet density
ORDERING INFORMATION
Description
Part Number
Cat. 6 RJ-45 unshielded Coupler
2111123-1
Cat. 6 RJ-45 shielded Coupler
2111124-1
230
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6 - Outlets
Category 6 DIN Dual Floor Outlet
FEATURES
• Category 6 Pyramid Tested
• Flat die-cast design for easy floor box mounting
• 50 x 50 mm faceplate universal fit
• LSA-PLUS tool compatible enhanced 110 IDC blocks
• Universal label for TIA 568A or TIA 568B wiring
• Protected PCB
ORDERING INFORMATION
Description
Part Number
Floor outlet; Ports: 2; Color: almond (RAL 1013)
336539-1
2-336539-1
12. Modular Twisted Pair Cabling
Floor outlet; Ports: 2; Color: pure white (RAL 9010)
318108AE 12/13 www.te.com/enterprise-asia
231
Modular Twisted Pair
Category 6 - Patch Panels
Cat. 6 SL Series Patch Panels
FEATURES:
• Meets or exceeds TIA and ISO Cat. 6
component performance requirements
• Ports may be individually replaced
B
• Packaged unloaded with jacks bagged separately
for termination with SL Series Jack Termination Tool
A
• Universal wiring — may be terminated
to T568A or T568B
• 12-Port Mini Patch Panels mount vertically
on 89D bracket (included)
Color: Black
ORDERING INFORMATION
12. Modular Twisted Pair Cabling
Description
Height
Width
Figure
12-Port
10.00"
2.3"
A
Part Number
1375013-2
24-Port
1U (1.75")
19.0"
–
1-1375014-3*
24-Port
1U (1.75")
19.0"
–
1933796-2
48-Port
2U (3.50")
19.0"
B
1375015-2
48-Port
2U (3.50")
19.0"
B
1933797-2
96-Port
4U (7.00")
19.0"
–
1375016-2
*For Korean market only.
Cat. 6 Angled SL Series Patch Panels
FEATURES:
• Meets or exceeds TIA and ISO Cat. 6 component
performance requirements
A
• Allow elimination of horizontal cable management for
higher rack densities and ease of cable dress
• Ports may be individually replaced
B
• Packaged unloaded with jacks bagged separately for
termination with SL Series Jack Termination Tool
• Universal wiring — may be terminated to T568A or T568B
Color: Black
ORDERING INFORMATION
Description
Height
Width
Figure
24-Port
1U (1.75")
19.0"
A
1933798-2
48-Port
2U (3.50")
19.0"
B
1933799-2
232
Part Number
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6 - Patch Panels
Category 6 24 Ports Shielded Patch Panel FEATURES
• 19”, 1U, RJ-45 Patch Panel with 24 ports
• Class EA Permanent Link and Category 6 Pyramid Tested
• Prepared for AMPTRAC upgrade
• Enhanced 110 IDC blocks compatible with 110C
Impact or LSA-PLUS Insertion tool
• Rear cable management
• Cover adapts to different cable diameters via variable snap-in position
• Shield connection separated from strain relief
• Universal wiring - T568 A or B wiring pattern
• Including grounding bolt
• Protected PCB
ORDERING INFORMATION
Description
Part Number
Cat. 6 24 Ports Shielded Patch Panel; Color: black (RAL 9005)
1644042-2
Cat. 6 24 Ports Shielded Patch Panel; Color: light grey (RAL 7035)
1644042-3
12. Modular Twisted Pair Cabling
Category 6 24 Ports Unshielded Patch Panel FEATURES
• 19”, 1U, RJ-45 Patch Panel with 24 ports
• Category 6 Pyramid Tested
• Prepared for AMPTRAC upgrade
• Enhanced 110 IDC blocks compatible with 110C
Impact or LSA-PLUS Insertion tool
• Rear cable management
• Universal wiring - T568 A or B wiring pattern
• Including grounding bolt
• Protected PCB
ORDERING INFORMATION
Description
Part Number
Cat. 6 24 Ports Unshielded Patch Panel; Color: black (RAL 9005)
1711147-2
318108AE 12/13 www.te.com/enterprise-asia
233
Modular Twisted Pair
Category 6 - Consolidation Point
AMP-TWIST 6S to AMP-TWIST 7AS Consolidation Point
Transition Cable Assembly
FEATURES
• Assembly to connect the work area outlet with the consolidation
or transition point
• Saves time and money on moves, adds and changes
• According to ISO/IEC 11801
• Category 7 S/FTP solid cable acc. to IEC 61156-5 and EN 50288-4-1
• LSFRZH sheath
• Universal wiring
Color: white
ORDERING INFORMATION
Y- -X
Length
0- -5
5.0 m
1- -4
7.5 m
1- -0
10.0 m
Description
Part Number
1- -5
15.0 m
AMP-TWIST 6S SL jack w/o dust cover to AMP-TWIST 7AS plug; Class EA
Y-1711666-X
2- -0
20.0 m
AMP-TWIST 6S SL jack with dust cover to AMP-TWIST 7AS plug; Class EA
Y-1711777-X
3- -0
30.0 m
Y- -X
Length
0- -5
5.0 m
Unshielded Consolidation Point Transition Cable Assemblies
12. Modular Twisted Pair Cabling
FEATURES
• Assembly to connect the work area outlet with the consolidation
or transition point (SL 110C Jack to modular plug)
• Meets ISO/IEC 11801 and EN 50173-1
• 4 pair solid U/UTP cable
• LSZH sheath
• Universal wiring
Color: white
ORDERING INFORMATION
1- -4
7.5 m
1- -0
10.0 m
Description
Part Number
1- -5
15.0 m
Cat. 6; Class E
Y-1711027-X
2- -0
20.0 m
234
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6 - Consolidation Point
Consolidation Point Transition Cable Assemblies
FEATURES:
• Meets ISO/IEC 11801 and EN 50173-1
• Patch cord RJ-45 to RJ-45 Cat. 6
• 4 pair solid U/UTP cable
• CMR sheath
• TIA/EIA T568B wiring
Color: blue
Y-X
ORDERING INFORMATION
Length
0- -5
5.0 m
1- -0
10.0 m
Part Number
1- -5
15.0 m
Consolidation Point Transition Cable Assemblies
Y-1427314-X
2- -0
20.0 m
12. Modular Twisted Pair Cabling
Description
318108AE 12/13 www.te.com/enterprise-asia
235
Modular Twisted Pair
Category 6 - Patch Cords
Category 6 F/UTP Patch Cord RJ45 LSZH
FEATURES
• Meets or exceeds the channel specification
of TIA-568-C.2 Category 6 shielded and
Amendment 1 to ISO11801:2002 Class E
• Flexible color boot
• 4-Pair stranded shielded cable
• LSZH cable jacket
• RoHS compliant
ORDER INFORMATION
Y- -X
Length
Description
Part Number
0- -5
1.0 m
White/White boot
Y-1427226-X
0- -6
2.0 m
White/Gray boot
Y-1427266-X
0- -7
3.0 m
White/Blue boot
Y-1427269-X
0- -8
5.0 m
Yellow/Yellow boot
Y-1427363-X
1- -1
10.0 m
Gray/Gray boot
Y-1859300-X
Other lengths are
available upon request.
Other colors are available on request
Category 6 U/UTP Patch Cord RJ-45 LSZH
12. Modular Twisted Pair Cabling
FEATURES
• Meets or exceeds the channel specification of TIA568-C.2 Category 6 and ISO11801:2002 Class E
• Transparent, flexible SL boot
• 4-Pair stranded unshielded conductors
• LSZH cable jacket
• RoHS compliant
ORDERING INFORMATION
Description
Part Number
Y- -X
Length
White
Y-1859280-X
0- -1
1.0 m
Blue
Y-1859277-X
0- -2
2.0 m
Gray
Y-1859275-X
0- -3
3.0 m
Yellow
Y-1859281-X
0- -5
5.0 m
Red
Y-1859279-X
1- -0
10.0 m
Other lengths are
available upon request.
Other colors are available upon request.
236
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6 - Patch Cords
Category 6 U/UTP Patch Cord RJ45 CM Slimline
FEATURES
• Meets or exceeds the channel specification of TIA568-C.2 Category 6 and ISO11801:2002 Class E
• Transparent, flexible SL boot
• 4-Pair stranded unshielded conductors
• FRPVC CM cable jacket
• RoHS compliant
ORDERING INFORMATION
Y- -X
Length
1 ft
4 ft
Description
Part Number
0- -1
White
Y-1859250-X
0- -4
Blue
Y-1859247-X
0- -7
7 ft
Gray
Y-1859246-X
1- -0
10 ft
Yellow
Y-1859251-X
1- -5
15 ft
Red
Y-1859249-X
Other lengths are
available upon request.
Other colors are available upon request.
12. Modular Twisted Pair Cabling
Category 6 U/UTP Patch Cord RJ45 CM 28AWG
FEATURES
• Meets or exceeds the patch cord specification
of TIA-568-C.2 Category 6
• 28AWG stranded unshielded conductors
• 3.9mm cable OD
• More than 50% space saving compared to 24AWG Cat. 6 UTP patch cord
• Limited length
• Transparent, flexible SL boot
• FRPVC CM cable jacket
• RoHS compliant
ORDERING INFORMATION
Description
Part Number
Y- -X
Length
White
Y-1859535-X
0- -1
1.0 m
Blue
Y-1859532-X
0- -2
2.0 m
Gray
Y-1859531-X
0- -3
3.0 m
Yellow
Y-1859536-X
0- -5
5.0 m
Red
Y-1859534-X
1- -0
10.0 m
Other lengths are
available upon request.
Other colors are available upon request.
318108AE 12/13 www.te.com/enterprise-asia
237
Modular Twisted Pair
Category 6 - HighBand
HighBand Solution
TE Connectivity's HighBand cross connect solution allows for maximum network throughput beyond
one Gigabit. It is the platform needed for the most advanced networks.
The HighBand solution consists of high performance disconnection modules, user friendly cable management and
innovative anti-snag patch cords. It is the ideal cabling solution for companies that are conscious of efficiency,
guaranteed performance and appealing aesthetics.
Modules can be either patched or jumpered and used in a Patch-by-Exception structured cabling solution. Patch-byException solutions offer material, installation and operational cost savings over traditional RJ45 products. In all newly
installed PBE systems there are no patch cords or jumper cables visible to the front. The system is totally hard wired from
network equipment to work area, providing a secure, reliable, high performance infrastructure from switch to work area,
or PABX to telephone.
HighBand utilises the silver plated, world renowned LSA-PLUS contact principle. This technology has become the
industry standard in over 140 countries. The gas tight contacts ensure a reliable and long lasting connection. The frequent
moves, adds and changes that occur in today’s cabling systems can quickly degrade the quality of wire termination. TE
Connectivity's products maintain superior connectivity during hundreds of re-terminations and deliver the best electrical
performance in the industry.
12. Modular Twisted Pair Cabling
FEATURES AND BENEFITS
• Unrivalled maximum headroom above
Category 6 standards
• T
he world’s only Category 6 24-pair disconnect
module providing unique Patch-by-Exception
functionality and improved administration
• Modules can be jumpered or patched (or both)
• A
test port provides “look-both-ways” testing
capability without the removal of any wires; also
allows simple circuit monitoring through use of
a test cord
• Integrates easily with all of TE Connectivity's solutions
• S
ilver plated LSA-PLUS contacts made
from superior spring copper alloy
• U
pper and lower shell mouldings made from
high quality PBT plastic
• A
vailable as individual components or in complete
systems, consisting of unique disconnect
modules, cable managers, covers, patch
cords, mounting frames and label holders
238
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6 - HighBand
HIGHBAND MODULE SPECIFICATIONS
MECHANICAL
Wire Range for solid and stranded copper conductors:
0.4mm to 0.65mm (26 to 22 AWG)*
Wire insulation diameter range (PE,PVC):
0.7mm to 1.4mm
Number of wire terminations:
≥200
Wire insertion force (0.5mm conductor dia): 6N
Wire pull out force, radial (0.5mm conductor dia):
≥5N
Wire pull out force, axial (0.5mm conductor dia):
≥35N
Number of patching cycles:750
ELECTRICAL
Transmission, performance and reliability:
:
:
Voltage rating:
Insulation resistance:
Exceeds ISO/IEC 11801 Class E
AS/NZS 3080:2002 Class E
TIA/EIA 568-B.2-1 Category 6
150 VAC
≥500,000 MΩ at 500 VDC
ENVIRONMENTAL AND SAFETY
Safety Compliance:
Flammability rating of plastic housing:
Environment for use:
Operating temperature range:
Maximum relative humidity:
UL 1863
UL 94 VO
Indoors or in dry enclosure rated IP54 or greater
-40°C to +80°C
≤93% non-condensing
318108AE 12/13 www.te.com/enterprise-asia
12. Modular Twisted Pair Cabling
*A maximum of 2 equal diameter solid conductors only, of up to 0.5mm conductor diameter can be
terminated per slot. Only 1 conductor of stranded wires per slot can be terminated. If any conductors
>0.5mm diameter have been terminated, reversal to smaller conductors is no longer possible.
239
Modular Twisted Pair
Category 6 - HighBand
3
2.2
2.3
2.4
2
2.1
1.1
1.3
1.2
12. Modular Twisted Pair Cabling
1
4
KEY
240
1
Cable Management Kit
1.1 Vertical Cable Manager (2)
1.2 Cover (1)
1.3 Bi-directional hinged clips (4)
2
HighBand Module Kit
2.1 12-way wall mount Frame (1)
2.2 Rear Cable Manager (12)
2.3 HighBand Module (12)
2.4 Label Holder Kit (12)
3
Cable Trough, top
4
Cable Trough, bottom
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6 - HighBand
HighBand Cross-Connect System
Colour coded for ease of installation, the HighBand module allows for
termination of 6, 4-pair (Category 6) UTP cables. HighBand offers the highest
performing Category 6 module in the world with transmission performance
headroom far exceeding all local and international standards.
The rear cable manager provides cable management for incoming cables and
makes installation easier. Incoming cables are held in place by built-in clips
that direct the cable to the point of termination. Each cable is secured firmly
preventing the need for additional cable or Velcro ties. The label holder clips
into position in three locations, providing a secure fit and allows patching and
jumpering to take place whilst it is fitted.
HighBand Category 6 Module
ORDERING INFORMATION
12-way Basic System
12-way Wall Mount Frame
HighBand Label Holder
Description
Quantity
Part Number
HighBand 12-way Kit
Consists of (1) wall mount frame, (12) 24-pair HighBand Category 6
modules including rear cable manager and (12) label holders.
Kit
6450 1 101-10
Kit
6450 1 102-10
Kit
6468 5 600-10
Kit
6468 5 300-10
Kit
6462 2 408-01
Box of 1
6450 2 155-01
HighBand 36-way Kit
Consists of (3) wall mount frames, (36) 24-pair HighBand Category 6
modules including rear cable manager and (36) label holders.
HighBand Category 6 Module Kit
Consists of (12) 24-pair HighBand Category 6 modules, (12)
label holders and (12) rear cable managers.
HighBand Category 3 Voice Module Kit
Consists of (12) 25-pair HighBand Voice modules, (12) label holders and (12) rear cable managers.
HighBand Label Holder Kit
Consists of (12) label holders, (12) paper inserts and (12) protective windows.
HighBand 12 way Wall Mount Frame
318108AE 12/13 www.te.com/enterprise-asia
241
12. Modular Twisted Pair Cabling
The 12-way wall mount frame is made from high-grade stainless steel, providing
strength and superior corrosion resistance. Extra depth has been provided to
allow for Category 6 bend radius requirements. Velcro tie off points have been
included to ensure tidy installation practices and ease of cable routing.
Modular Twisted Pair
Category 6 - HighBand
HighBand Cable Management
The cable management rings control vertical cable management between frames, ensuring that cables do not interfere
when adds, moves and changes occur. The dual cable manager is ideal for high density or heavily patched installations
and provides a neat, clean finish to the HighBand0 system. The single cable manager is best suited to either the start
or finish of the system. Cable troughs mounted on the top and bottom of each frame ensure superior patch cord
management and correct bend radius between frames.
Top Cable Trough
Cable Management
Rings
12. Modular Twisted Pair Cabling
Bottom Cable Trough
Vertical
Management Cover
ORDERING INFORMATION
Description
Quantity
HighBand 12-way Cable Management Kit
Part Number
Kit
6450 1 103-10
Kit
6450 1 104-10
Cable Management Rings
Bag of 2
6450 2 156-20
HighBand Cover
Box of 1
6450 2 158-20
HighBand Cable Trough, Top
Box of 1
6450 2 157-10
HighBand Cable Trough, bottom
Box of 1
6450 2 157-20
Includes (2) cable management rings and (1) cover.
HighBand 36-way Cable Management Kit
Includes (6) cable management rings and (3) covers.
242
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 6 - HighBand
19" Rack Installations
HighBand can also be used as a traditional cross connect
inside a 19" rack. The recessed frame ensures that the
modules sit flush with the front of the rack and other 19"
equipment that may already be in place within the rack.
A rear cable manager is also available to assist when other
cable management within the rack is not accessible.
HighBand 4-way Rack Kit
HighBand 8-way Rack Kit
Rear Cable Management Bar
ORDERING INFORMATION
HighBand 12-way Rack Kit
Description
Quantity
Dimensions
Kit
8.89cm (2RU)
6450 1 176-01
Box of 1
8.89cm (2RU)
6450 2 176-00
Kit
13.34cm (3RU)
6450 1 177-01
Box of 1
13.34cm (3RU)
6450 2 177-00
Kit
17.78cm (4RU)
6450 1 178-01
HighBand 12-way recessed frame (1)
Box of 1
17.78cm (4RU)
6450 2 178-00
HighBand Rear Cable Management Bar
Box of 1
4.45cm (1RU)
6450 1 210-00
HighBand 4-way Rack Kit
Part Number
HighBand 4-way Recessed Frame
HighBand 8-way Rack Kit
Consists of (8) 24-pair HighBand Category 6 modules,
(8) label holders and (1) 19" recessed frame.
HighBand 8-way Recessed Frame
For use with 8-way Rack Kit
HighBand 12-way Rack Kit
Consists of (12) 24-pair HighBand Category 6 modules,
(12) label holder kits and (1) 19" recessed frame.
HighBand Consolidation Point Kit
For use in horizontal cabling as a high-density
consolidation point, ideal for use inside a ceiling
or false floor. The modules clip directly on to the
specially designed metal wall mount frame. The
metal cover clips into place to protect the modules
from dust and foreign particles.
Consolidation Point Kit
ORDERING INFORMATION
Description
Quantity
HighBand Consolidation Point Kit
Kit
Part Number
6450 1 105-11
Consists of (5) 24-pair HighBand Category 6 modules, (5) label holders,
(1) wall mount frame and (1) protective cover.
318108AE 12/13 www.te.com/enterprise-asia
243
12. Modular Twisted Pair Cabling
Consists of (4) 24-pair Category 6 modules, (4) label
holders and (1) 19" recessed frame.
Modular Twisted Pair
Category 6 - HighBand
HighBand Patch Cords
The HighBand patch cords are Category 6 compliant and come in a number of
alternate styles to suit the various applications. The 4-pair rear facing patch cord
is ideally suited to the 300-pair and 900-pair systems. The 1-pair patch cord is
available for patching voice 1-pair to 1-pair or can also be utilised for single pair
testing. The front facing patch cords are ideal in rack mount installations or when
patching is common place.
1-pair Rear Facing
4-pair Front Facing
4-pair Rear Facing
12. Modular Twisted Pair Cabling
ORDERING INFORMATION
Description
Quantity
Length
Colour
Part Number.
HighBand Patch Cord, 4-pair to RJ45 Rear
Bag of 1
1.2m
Blue
6451 2 700C-10
HighBand Patch Cord, 4-pair to RJ45 Rear
Bag of 1
2.1m
Blue
6451 2 700C-20
HighBand Patch Cord, 4-pair to RJ45 Rear
Bag of 1
3.0m
Blue
6451 2 700C-30
HighBand Patch Cord, 4-pair to RJ45 Rear
Bag of 1
4.5m
Blue
6451 2 700C-40
HighBand Patch Cord, 4-pair to 4-pair Rear
Bag of 1
1.2m
Blue
6451 2 701C-10
HighBand Patch Cord, 4-pair to 4-pair Rear
Bag of 1
2.1m
Blue
6451 2 701C-20
HighBand Patch Cord, 4-pair to 4-pair Rear
Bag of 1
3.0m
Blue
6451 2 701C-30
6451 2 701C-40
HighBand Patch Cord, 4-pair to 4-pair Rear
Bag of 1
4.5m
Blue
HighBand Patch Cord, 1-pair to 1-pair Rear
Bag of 1
1.2m
White
6451 2 702-10
HighBand Patch Cord, 1-pair to 1-pair Rear
Bag of 1
2.1m
White
6451 2 702-20
HighBand Patch Cord, 1-pair to 1-pair Rear
Bag of 1
3.0m
White
6451 2 702-30
HighBand Patch Cord, 1-pair to 1-pair Rear
Bag of 1
4.5m
White
6451 2 702-40
HighBand Patch Cord, 4-pair to 4-pair Front
Bag of 1
1.2m
Blue
6451 2 703C-10
HighBand Patch Cord, 4-pair to 4-pair Front
Bag of 1
2.1m
Blue
6451 2 703C-20
HighBand Patch Cord, 4-pair to 4-pair Front
Bag of 1
3.0m
Blue
6451 2 703C-30
HighBand Patch Cord, 4-pair to 4-pair Front
Bag of 1
4.5m
Blue
6451 2 703C-40
HighBand Patch Cord, 4-pair to RJ45 Front
Bag of 1
1.2m
Blue
6451 2 704C-10
HighBand Patch Cord, 4-pair to RJ45 Front
Bag of 1
2.1m
Blue
6451 2 704C-20
HighBand Patch Cord, 4-pair to RJ45 Front
Bag of 1
3.0m
Blue
6451 2 704C-30
HighBand Patch Cord, 4-pair to RJ45 Front
Bag of 1
4.5m
Blue
6451 2 704C-40
244
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 5e - Cables
Category 5e SF/UTP Cable
FEATURES
• Qualified against IEC 61156-5 Category 5e and EN 50288-2-1
• Overall copper braid plus foil shield
• Very low delay skew, suitable for 1000Base-T
• AWG 24 solid conductor
Color: white
ORDERING INFORMATION
Description
Part Number
Sheathing: LSZH; Type: Simplex; OD 6.5 mm; Packaging: 500 m/Reel
219484-2
510 Series Category 5e F/UTP Twisted Pair Cable
FEATURES
• Qualified against IEC 61156-5 Category 5e and EN 50288-2-1
• Overall foil shield with drain wire
• AWG24 solid conductor
• RoHS Compliant
The following colors are available:
Replace “XX” with:
ORDERING INFORMATION
BL = Blue WT = White GY = Gray YL = Yellow
GN = Green RD = Red OR = Orange BK = Black
Rating
Pairs
OD(mm)
AWG
Part Number
PVC
4
6.2
24
TE510HF-XXYY-AP
LSZH
4
6.2
24
TE510Z1F-XXYY-AP
The following package is available:
Replace “YY” with:
MB-305m reel-in-box
318108AE 12/13 www.te.com/enterprise-asia
245
12. Modular Twisted Pair Cabling
• Meets or exceeds the cable specifications of TIA568-C.2 Category 5e and ISO11801:2002 Class D
Modular Twisted Pair
Category 5e - Cables
510 Series Category 5e U/UTP Twisted Pair Cable
FEATURES
• Meets or exceeds the cable specifications of TIA568-C.2 Category 5e and ISO11801:2002 Class D
• AWG24 solid conductor
• RoHS Compliant
ORDERING INFORMATION
Rating
Pairs
OD(mm)
AWG
CM
4
4.9
24
TE510M-XXYY-AP
CMR
4
4.9
24
TE510R-XXII
LSZH
4
5.1
24
TE510Z1-XXYY-AP
PVC
4
4.9
24
TE510H-XXYY-AP
The following jacket colors are available.
Replace “XX” with:
BL=Blue WT=White GY=Gray YL=Yellow GN=Green RD=Red OR=Orange BK=Black
12. Modular Twisted Pair Cabling
The following packages are available.
Replace “YY” with:
MI=305m reelex II
M7=200m reelex II(for PVC)
510 Series Category 5e U/UTP Twisted Pair Cable, 25 Pairs
Rating
Pairs
OD(mm)
AWG
Part Number
CM
25
13.0
24
CMR
25
13.0
24
TE510M25-XXYY-AP
TE510R25-XXYY
LSZH
25
13.0
24
TE510Z125-XXYY-AP
The following jacket colors are available.
Replace “XX” with:
WT=White GY=Gray
The following packages are available.
Replace “YY” with:
02= 1000FT reel
246
www.te.com/enterprise-asia 12/13 318108AE
Part Number
Modular Twisted Pair
Category 5e - Jacks
SL Series 110Connect Jacks (STP)
FEATURES
• Universal wiring-T568 A or B wiring pattern
• Category 5e
ORDERING INFORMATION
Description
Part Number
Cat. 5e RJ-45 shielded Jack without dust cover, 180° cable exit
1375189-1
SL Series 110Connect Jacks (UTP)
FEATURES
• SlimLine (SL) Series: Thin profile improves outlet density
• Category 5e
• Available with or without dust cover
• 90° or 180° cable dress for easy termination
• Bend-limiting strain relief included
• UL listed
• Several colors available on demand
ORDERING INFORMATION
Description
Part Number
Cat. 5e RJ-45 unshielded Jack without dust cover
Y-1375191-X
Cat. 5e RJ-45 unshielded Jack with dust cover
Y-1375190-X
318108AE 12/13 www.te.com/enterprise-asia
Y- -X
Color
0- -1
Beige
0- -2
Black
0- -3
White
0- -6
Blue
0- -7
Red
247
12. Modular Twisted Pair Cabling
• Universal wiring - T568 A or B wiring pattern
Modular Twisted Pair
Category 5e - Jacks
SL Series Modular Coupler
FEATURES
• Straight Category 5e coupler
• Compact coupler for two modular plugs
• SL Series: Thin profile improves outlet density
ORDERING INFORMATION
Description
Part Number
Cat. 5e RJ-45 unshielded Coupler
2111121-1
Cat. 5e RJ-45 shielded Coupler
2111122-1
12. Modular Twisted Pair Cabling
248
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 5e - Patch Panels
Category 5e 24 Ports Shielded Patch Panel
FEATURES
• 19”, 1U, RJ-45 Patch Panel with 24 ports
• Category 5e
• Available as LSA-PLUS and 110Connect Version
- LSA-PLUS Version: Enhanced LSA-PLUS IDC blocks
compatible with LSA-PLUS Insertion tool
- 110Connect Version: Enhanced 110C IDC blocks compatible
with 110C Impact tool and LSA-PLUS Insertion tool
• Rear cable management
• Shield connection separated from strain relief
• Universal wiring - T568 A or B wiring pattern
• Including grounding bolt
• Protected PCB
Color: black (RAL 9005)
ORDERING INFORMATION
Part Number
Cat. 5e 24 Ports Shielded Patch Panel with 110C IDC blocks
Cat. 5e 24 Ports Shielded Patch Panel with LSA-PLUS IDC blocks
336671-2
7022 1 015-24
318108AE 12/13 www.te.com/enterprise-asia
12. Modular Twisted Pair Cabling
Description
249
Modular Twisted Pair
Category 5e - Patch Panels
Cat. 5e Angled SL Series Patch Panels
FEATURES:
• Meets or exceeds TIA and ISO Cat. 5e/Class D
component performance requirements
A
elimination of horizontal cable management for
• Allow
higher rack densities and ease of cable dress
• Ports may be individually replaced
B
• Packaged unloaded with jacks bagged separately for
termination with SL Series Jack Termination Tool
• Universal wiring — may be terminated to T568A or T568B
Color: Black
ORDERING INFORMATION
Description
Height
Width
Figure
24-Port
1U (1.75")
19.0"
A
Part Number
1499602-2
48-Port
2U (3.50")
19.0"
B
1499603-2
12. Modular Twisted Pair Cabling
Cat. 5e SL Series Patch Panels
FEATURES:
• Meets or exceeds TIA and ISO Cat. 5e/Class
D component performance requirements
• Ports may be individually replaced
B
• Packaged unloaded with jacks bagged separately for
termination with SL Series Jack Termination Tool
• Universal wiring — may be terminated
to T568A or T568B
• 12-Port Mini Patch Panels mount vertically
on 89D bracket (included)
ORDERING INFORMATION
Description
Height
Width
Figure
12-Port
10.00"
2.3"
A
1479153-2
24-Port
1U (1.75")
19.0"
–
1479154-2
48-Port
2U (3.50")
19.0"
B
1479155-2
96-Port
4U (7.00")
19.0"
–
1479156-2
250
Part Number
www.te.com/enterprise-asia 12/13 318108AE
A
Modular Twisted Pair
Category 5e - Patch Panels
Category 5e 24 Ports Unshielded Patch Panel
FEATURES
• 19”, 1U, RJ-45 Patch Panel with 24 ports
• Category 5e
• Enhanced LSA-PLUS IDC blocks compatible
with LSA-PLUS Insertion tool
• Rear cable management
• Universal wiring - T568 A or B wiring pattern
• Including grounding bolt
• Protected PCB
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Cat. 5e 24 Ports Unshielded Patch Panel
6527 1 607-24
FEATURES:
• Meets or exceeds TIA and ISO Cat. 5e/Class D
component performance requirements
12. Modular Twisted Pair Cabling
Cat. 5e 110Connect Patch Panels
B
• May be terminated using single-wire or 5-pair tools
• Universal wiring — may be terminated to T568A or T568B
• 12-Port Mini Patch Panels mount vertically
on 89D bracket (included)
ORDERING INFORMATION
A
Description
Height
Width
Figure
Part Number
12-Port
10.00"
2.3"
A
406390-1
12-Port
1U (1.75")
19.0"
—
406981-1
24-Port
1U (1.75")
19.0"
—
406330-1
24-Port
1U (1.75")
19.0"
—
1-406330-3*
48-Port
2U (3.50")
19.0"
B
406331-1
96-Port
4U (7.00")
19.0"
–
406332-1
*For Korea market only.
318108AE 12/13 www.te.com/enterprise-asia
251
Modular Twisted Pair
Category 5e - Consolidation Point
Unshielded Consolidation Point Transition Cable Assemblies
FEATURES
• Assembly to connect the work area outlet with the consolidation
or transition point (SL 110C Jack to modular plug)
• Meets ISO/IEC 11801 and EN 50173-1
• 4 pair solid U/UTP cable
• LSZH sheath
• Universal wiring
Color: white
ORDERING INFORMATION
Y- -X
Length
0- -5
5.0 m
1- -4
7.5 m
1- -0
10.0 m
Description
Part Number
1- -5
15.0 m
Cat. 5e; Class D
Y-1711040-X
2- -0
20.0 m
12. Modular Twisted Pair Cabling
252
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 5e - Patch Cords
Solid Core Patch Cords
For use in data centres and communications rooms to enable ‘hard-wired’
connections between patch panels and active networking equipment.
Wired to T568-B and complete with terminated plugs at both
ends, patch cords are 100% tested and warranted to exceed
specification requirements.
TEST SPECIFICATION
Exceeds specifications according to ISO/IEC 11801:2002,
EN 50173-1:2002 and TIA/EIA 568-B
Fire rating is IEC 60332-1
FEATURES
• Performance exceeding Category 5e specifications up to 100MHz
• Wired to T568-B
• Complete with integrated strain relief to
protect terminations within the plug
ORDERING INFORMATION
-XX
Length
-10
10 m
Part Number
-20
20 m
Patch Cord, Solid, Category 5e U/UTP, LSZH, Blue
6529 1 202-XX
-30
30 m
Patch Cord, Solid, Category 5e U/UTP, LSZH, White
6529 1 203-XX
-40
40 m
Patch Cord, Solid, Category 5e U/UTP, LSZH, Orange
6529 1 205-XX
-50
50 m
Description
Other colors and lengths are available upon request
318108AE 12/13 www.te.com/enterprise-asia
253
12. Modular Twisted Pair Cabling
• Fully interoperable and backwards compatible
Modular Twisted Pair
Category 5e - Patch Cords
Category 5e F/UTP Patch Cord RJ45 LSZH
FEATURES
• Meets or exceeds the channel specification of TIA-568-C.2 Category
5e shielded and Amendment 1 to ISO11801:2002 Class D
• Flexible color boot
• 4-Pair stranded shielded cable
• LSZH cable jacket
• RoHS compliant
ORDERING INFORMATION
Description
Part Number
White/White boot
Y-1427290-X
Blue/Blue boot
Y-1427288-X
Gray/Gray boot
Y-1427305-X
Yellow/Yellow boot
Y-1427275-X
Red/Red boot
Y-1427289-X
Other colors available upon request
Y- -X
Length
0- -5
1m
0- -6
2m
0- -7
3m
0- -8
5m
1- -1
10m
Other lengths available upon request
Category 5e U/UTP Patch Cord RJ45 LSZH
12. Modular Twisted Pair Cabling
FEATURES
• Meets or exceeds the patch cord specification of TIA568-C.2 Category 5e and ISO11801:2002 Class D
• Transparent, flexible SL boot
• 4-Pair stranded unshielded conductors
• LSZH cable jacket
• RoHS compliant
ORDERING INFORMATION
Description
Part Number
Y- -X
Length
White
Y-1859691-X
0- -1
1m
Blue
Y-1859690-X
0- -2
2m
Gray
Y-1859692-X
0- -3
3m
Yellow
Y-1859694-X
0- -5
5m
Red
Y-1859695-X
1- -0
10m
Other lengths available upon request
Other colors available upon request
254
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Category 5e - Patch Cords
Category 5e U/UTP Patch Cord RJ45 CM
FEATURES
• Meets or exceeds the channel specification of TIA568-C.2 Category 5e and ISO11801:2002 Class D
• Transparent, flexible SL boot
• 4-Pair stranded unshielded conductors
• FRPVC CM cable jacket
• RoHS compliant
ORDERING INFORMATION
Description
Part Number
White
Y-1859242-X
Y- -X
Length
0- -1
1 ft
0- -4
4 ft
Blue
Y-1859239-X
Gray
Y-1859238-X
0- -7
7 ft
Yellow
Y-1859243-X
1- -0
10 ft
Y-1859240-X
1- -5
15 ft
Red
Other colors available upon request
12. Modular Twisted Pair Cabling
Other lengths available upon request
318108AE 12/13 www.te.com/enterprise-asia
255
Modular Twisted Pair
110Connect XC System
110Connect XC Cat. 5e Connecting Blocks
FEATURES
• Utilize double-ended insulation displacement contacts
(IDC) that terminate 24-22 AWG solid or stranded
conductors with a maximum O.D. of .063 inch
• Available in 4- and 5-pair sizes with
the appropriate color coding
A
ORDERING INFORMATION
Description
Figure
Connecting Blocks
B
Part Number
4-Pair
A
558401-1
5-Pair
B
558402-1
110 Connect XC Cat. 5e Wiring Blocks
FEATURES
• Accept 24-22 AWG conductors
12. Modular Twisted Pair Cabling
• Blocks are available in 50-, 100 and 300pair sizes with legs for backboard mounting
A
ORDERING INFORMATION
Description
Wiring Blocks
Figure
With Legs
Without Legs
256
Part Number
50-Pair
-
558841-1
100-Pair
A
558842-1
300-Pair
-
558843-1
50-Pair
-
558839-1
100-Pair
B
558840-1
www.te.com/enterprise-asia 12/13 318108AE
B
Modular Twisted Pair
110Connect XC System
110Connect XC Cat. 5e Kits
FEATURES
• Kits include wiring blocks with legs, connecting blocks,
designation strips and white labels for the pair counts identified
ORDERING INFORMATION
Description
50-Pair
100-Pair
300-Pair
Part Number
4- & 5-Pair Connecting Blocks
569433-1
5-Pair Connecting Blocks
569434-1
4- & 5-Pair Connecting Blocks
569439-1
5-Pair Connecting Blocks
569440-1
4- & 5-Pair Connecting Blocks
569445-1
5-Pair Connecting Blocks
569446-1
Adapter for 89B Bracket
FEATURES
• Used to mount a 50-pair 110Connect XC wiring block on an 89B bracket
• Two adapters are required for each assembly
12. Modular Twisted Pair Cabling
• Wiring blocks and 89B brackets purchased separately
ORDERING INFORMATION
Description
Part Number
Adapter for 89B Bracket
558838-1
110Connect XC Cat. 5e Cross-Connect Distribution Frame Kits
FEATURES
• Reduce time needed for planning and installing a cross-connect on a backboard
• Include metal back frame, wiring blocks, connecting blocks, cable management
troughs, designation strips and appropriate hardware
• Quick and easy installation
• Available in 300- and 900-pair sizes with either 4- or 5-pair connecting blocks
ORDERING INFORMATION
Description
300-Pair
900-Pair
Part Number
4- & 5-Pair
569854-1
5-Pair
569855-1
4- & 5-Pair
569857-1
5-Pair
569858-1
318108AE 12/13 www.te.com/enterprise-asia
257
Modular Twisted Pair
110Connect XC System
110Connect XC Cable Management
FEATURES
• Cable Management Frames and Cable Management Rings
provide high capacity storage of patch cables and jumper wire
• Cable Management Trough provides horizontal management
and organization of patch cables and jumper wire
• Troughs are available with or without legs
• Suitable for mounting directly to a plywood backboard
• Quick and easy installation
A
C
B
ORDERING INFORMATION
Description
Figure
Cable Management Trough
White
Vertical Cable Management Frame
12. Modular Twisted Pair Cabling
With Legs
A
569389-1
Without Legs
–
569597-1
300-Pair
B
569851-1
900-Pair
-
569852-1
5.7” W
C
569431-1
8.5” W
–
569599-1
White
Cable Management Rings
Part Number
Black
110Connect XC Cat. 5e Cross-Connect Rack Mount Panel
FEATURES
• For mounting cross-connect hardware on a 19" rack
A
• Wiring block and cable management panels available
• Connecting blocks and plastic label covers purchased separately
• Rack Mount Cable Management Panels provide horizontal
management and organization of patch cables and jumper wire
B
ORDERING INFORMATION
Description
110Connect XC Cross-Connect Rack Mount
Panel Kits
Cable Management Trough Rack Mount
Panel
258
Pair Count
Height
Width
Figure
100-Pair
1U (1.75")
19"
–
558635-1
200-Pair
2U (3.50")
19"
A
558637-1
400-Pair
5U (8.75")
19"
–
558639-1
–
2U (3.50")
19"
B
406641-1
www.te.com/enterprise-asia 12/13 318108AE
Part Number
Modular Twisted Pair
110Connect XC System
5e 110XC to RJ-45 Patch Cord
FEATURES:
• Patch cord 110XC to RJ-45 Cat. 5e
• 4 Pair stranded U/UTP cable, AWG 24
conductors, universal wiring
• PVC sheath
• UL listed
Color: Grey
Y-X
Length
0- -2
0.6 m
0- -4
1.2 m
0- -6
1.8 m
0- -8
2.4 m
1- -0
3.0 m
ORDERING INFORMATION
Description
Wiring Pattern
Part Number
2 pairs 110XC to RJ-45
T568A/10BASE-T
2 pairs 110XC to RJ-45
T568B/10BASE-T
Y-569669-X
4 pairs 110XC to RJ-45
T568A
Y-569527-X
4 pairs 110XC to RJ-45
T568B
Y-569528-X
Y-569685-X
Cat. 5e 110XC to 110XC Patch Cord
• 4 Pair stranded U/UTP cable,
AWG 24 conductors, universal wiring
Y-X
Length
0- -2
0.6 m
• PVC sheath
0- -4
1.2 m
• UL listed
0- -6
1.8 m
0- -8
2.4 m
1- -0
3.0 m
Color: Grey
12. Modular Twisted Pair Cabling
FEATURES:
• Patch cord 110XC to 110XC Cat. 5e
ORDERING INFORMATION
Description
Part Number
1 pair 110XC to 110XC
Y-569523-X
2 pairs 110XC to 110XC
Y-569524-X
4 pairs 110XC to 110XC
Y-569526-X
318108AE 12/13 www.te.com/enterprise-asia
259
Modular Twisted Pair
HighBand
HighBand® 300-pair Broadband Kit
Ideal as a high density Category 5e wall mount crossconnect solution. Consists of (1) Backmount frame,
(12) 25-pair Broadband Category 5e modules
numbered 1-25, (12) rear cable managers and
(12) label holders.
HighBand 300-pair Broadband Kit
ORDERING INFORMATION
Description
Quantity
HighBand 300-pair Broadband Kit
Kit
Part Number
6450 1 101-11
12. Modular Twisted Pair Cabling
HighBand® 19" 300-pair Broadband Kit
Used in 19" rack mount installations. Consists of
(12) Broadband Category 5e modules, (12) label holder kits
and (1) 4RU 19" recessed frame.
HighBand 19" 300-pair Broadband Kit
ORDERING INFORMATION
Description
HighBand 19" 300-pair Broadband Kit
260
Quantity
Kit
Part Number
6450 1 180-00
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
HighBand
HighBand® 10 Disconnect Module
Category 5e Disconnect Module for termination of 10
incoming and 10 outgoing pairs. Pairs numbered 1-10.
Ideal for use in backbone cabling where high density and
disconnect features are required. Can be used in a
Patch-by-Exception solution. For mounting on both Profil®
and Backmount frames.
HighBand 10 Disconnect Module
ORDERING INFORMATION
Description
Quantity
Colour
Part Number
HighBand 10 Disconnect Module
Box of 10
White
6468 5 061-00
Compact Category 5e Module for termination of 2,
4-pair cables. Pairs numbered 1-8. For mounting on Profil
or Backmount frames specially designed for an 8-pair
footprint only.
HighBand Compact 8 Disconnect Module
ORDERING INFORMATION
Description
Quantity
Colour
Part Number
HighBand Compact 8 Disconnect Module
Box of 10
White
6468 5 061-08
318108AE 12/13 www.te.com/enterprise-asia
261
12. Modular Twisted Pair Cabling
HighBand® Compact 8 Disconnect Module
Modular Twisted Pair
HighBand
HighBand® 16 Switching Module
Category 5e Switching Module for termination
of 4 incoming 4-pair cables and 4 outgoing
4-pair cables. Colour coded for ease of
termination. Ideal for use in horizontal cabling
where high density is required. Cannot be
used in a Patch-by-Exception solution. For
mounting on both Profil® and Backmount
frames.
HighBand 16 Switching Module
ORDERING INFORMATION
Description
Quantity
Colour
Part Number
HighBand 16 Switching Module
Box of 10
White
6468 5 080-00
HighBand® 20 Switching Module
12. Modular Twisted Pair Cabling
Category 5e Switching Module for termination
of 20 incoming and 20 outgoing pairs. Ideal
for use in backbone cabling where high
density is required. Cannot be used in a
Patch-by-Exception solution. For mounting on
both Profil® and Backmount frames.
HighBand 20 Switching Module
ORDERING INFORMATION
Description
Quantity
Colour
Part Number
HighBand 20 Switching Module
Box of 10
White
6468 5 081-00
262
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
HighBand
HighBand® 16 Patch Cord, 4-pair
Used for patching 4 pairs between HighBand
16 modules.
HighBand 16 Patch Cord, 4-pair
(2 Patch Cords shown)
ORDERING INFORMATION
Quantity
Length
Colour
Part Number
HighBand 16 Patch Cord, 4-pair
Bag of 2
1.0m
Blue
6451 2 050-11
HighBand 16 Patch Cord, 4-pair
Bag of 2
2.0m
Blue
6451 2 050-21
HighBand 16 Patch Cord, 4-pair
Bag of 2
3.0m
Blue
6451 2 050-31
HighBand 16 Patch Cord, 4-pair
Bag of 2
5.0m
Blue
6451 2 050-51
HighBand® 16 Patch Cord, 4-pair to RJ45
Used for patching 4 pairs on a HighBand 16 module to
an RJ45 outlet.
HighBand Patch Cord, 4-pair to RJ45
(2 Patch Cords shown)
ORDERING INFORMATION
Description
Quantity
Length
Colour
Part Number
HighBand 16 Patch Cord, 4-pair to RJ45
Bag of 2
1.0m
Blue
6451 2 057-11
HighBand 16 Patch Cord, 4-pair to RJ45
Bag of 2
2.0m
Blue
6451 2 057-21
HighBand 16 Patch Cord, 4-pair to RJ45
Bag of 2
3.0m
Blue
6451 2 057-31
HighBand 16 Patch Cord, 4-pair to RJ45
Bag of 2
5.0m
Blue
6451 2 057-51
318108AE 12/13 www.te.com/enterprise-asia
263
12. Modular Twisted Pair Cabling
Description
Modular Twisted Pair
HighBand
HighBand® 10 Patch Cord, 4-pair to 4-pair
Used to patch 4 pairs on HighBand 10 modules only.
Can be used in a Patch-by-Exception solution to break the
original circuit and patch the signal to a new location.
HighBand 10 Patch Cord, 4-pair
(2 Patch Cords shown)
ORDERING INFORMATION
Description
Quantity
Length
Colour
Part Number
HighBand 10 Patch Cord, 4-pair
Bag of 2
1.0m
Blue
6451 2 101-10
HighBand 10 Patch Cord, 4-pair
Bag of 2
2.0m
Blue
6451 2 101-20
HighBand 10 Patch Cord, 4-pair
Bag of 2
3.0m
Blue
6451 2 101-30
HighBand® 10 Patch Cord, 4-pair to RJ45
Used to patch 4 pairs on a HighBand 10 module to an
RJ45 outlet.
12. Modular Twisted Pair Cabling
HighBand 10 Patch Cord, 4-pair to RJ45
ORDERING INFORMATION
Description
Quantity
Length
Colour
Part Number
HighBand 10 Patch Cord, 4-pair to RJ45
Bag of 2
1.0m
Blue
6451 2 102-10
HighBand 10 Patch Cord, 4-pair to RJ45
Bag of 2
2.0m
Blue
6451 2 102-20
HighBand 10 Patch Cord, 4-pair to RJ45
Bag of 2
3.0m
Blue
6451 2 102-30
HighBand® 10 Patch Cord, 2-pair to RJ45
Used for 2-pair patching on a HighBand 10 module to an
RJ45 outlet.
HighBand 10 Patch Cord, 2-pair to RJ45
ORDERING INFORMATION
Description
Quantity
Length
Colour
Part Number
HighBand 10 Patch Cord, 2-pair to RJ45
Bag of 2
1.0m
Blue
6451 2 104-10
HighBand 10 Patch Cord, 2-pair to RJ45
Bag of 2
2.0m
Blue
6451 2 104-20
HighBand 10 Patch Cord, 2-pair to RJ45
Bag of 2
3.0m
Blue
6451 2 104-30
264
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
HighBand
HighBand® 10 Test Cord, 4-pair to RJ45
Used for 4-pair testing on HighBand 10 modules. RJ45 end
allows connection to test equipment.
HighBand 10 Test Cord, 4-pair to RJ45
ORDERING INFORMATION
Description
Quantity
Length
Colour
HighBand 10 Test Cord, 4-pair to RJ45
Bag of 1
3.0m
Blue
Part Number
6451 2 099-30
HighBand® 10 Test Cord, 2-pair to RJ45
HighBand 10 Test Cord, 2-pair to RJ45
ORDERING INFORMATION
Description
Quantity
Length
Colour
HighBand 10 Test Cord, 2-pair to RJ45
Bag of 1
3.0m
Blue
318108AE 12/13 www.te.com/enterprise-asia
Part Number
6451 2 100-30
265
12. Modular Twisted Pair Cabling
Used for 2-pair testing on HighBand 10 modules.
RJ45 end allows connection to test equipment.
Modular Twisted Pair
Voice - Backbone Cable
310 Series Category 3 U/UTP Backbone Cable
FEATURES
• Meets or exceeds the specifications of TIA568-C.2 Category 3 backbone cable
• RoHS Compliant
Color: white
ORDERING INFORMATION
Rating
Pairs
OD(mm)
AWG
CM
50
13.0
26
TE310M50-GYYY-AP
CM
100
18.0
26
TE310M100-GYYY-AP
CMR
25
10.0
24
TE310R25-GYYY-AP
CMR
50
15.0
24
T310R50-GYYY-AP
CMR
100
20.0
24
TE310R100-GYYY-AP
LSZH
25
8.3
24
TE510Z125-GYXX-AP
LSZH
50
15.0
24
TE310Z150-GYXX-AP
LSZH
100
25.0
24
TE310Z100-GYXX-AP
The following package are available.
Replace “YY” with:
02-1000FT reel
07-3300FT reel
12. Modular Twisted Pair Cabling
Replace “XX” with:
M2-305m reel
M3-500m reel
266
09-1640FT reel
M6-1000m reel
www.te.com/enterprise-asia 12/13 318108AE
Part Number
Modular Twisted Pair
Voice - Jacks
SL Series Modular Jack (UTP)
FEATURES
• SlimLine (SL) Series: Thin profile improves outlet density
• Category 3
• 90° or 180° cable dress for easy termination
• Bend-limiting strain relief included
• UL listed
• Universal wiring - T568 A or B wiring pattern
• Several colors available on demand
ORDERING INFORMATION
Y- -X
Color
0- -1
Beige
0- -2
Black
Description
Part Number
0- -6
Blue
Cat. 3 RJ-11 unshielded Jack without dust cover
Y-1375192-X
1- -3
Alpine White
SL Series Modular Coupler
FEATURES
• Straight Category 3 telephone coupler
12. Modular Twisted Pair Cabling
• Compact coupler for two modular plugs
• SL Series: Thin profile improves outlet density
ORDERING INFORMATION
Description
Part Number
Cat. 3 RJ-11 (6 pos) unshielded Coupler
555050-1
Cat. 3 RJ-45 (8 pos) unshielded Coupler
555052-1
318108AE 12/13 www.te.com/enterprise-asia
267
Modular Twisted Pair
Voice - Jacks
SL Series Multimedia Inserts
FEATURES
• The inserts offer flexibility and density at the work area outlet
• Can be installed in any faceplate or outlet designed to the SL series jack footprint
Y- -X
Color
0- -1
Light Almond
0- -2
Black
1- -3
Alpine White
• Some couplers may not be available in all colors
ORDERING INFORMATION
12. Modular Twisted Pair Cabling
Description
Part Number
ST Coupler; Fiber Type: Multimode
Y-1339123-X
ST Coupler; Fiber Type: Singlemode
Y-1479181-X
BNC Coupler Insert; Figure B
Y-2111615-X
MT-RJ SL Series Housing
Y-1374416-X
RCA Coupler, Red Dielectric
Y-1375361-X
RCA Coupler, White Dielectric
Y-1375362-X
RCA Coupler, Yellow Dielectric
Y-1375363-X
RCA Solder Termination, Red Dielectric
Y-1375364-X
RCA Solder Termination, White Dielectric
Y-1375365-X
RCA Solder Termination, Yellow Dielectric
Y-1375366-X
RCA Coupler, Green Dielectric
Y-1933192-X
RCA Coupler, Blue Dielectric
Y-1933193-X
RCA Coupler, Orange Dielectric
Y-1933194-X
RCA to F-Connector; Figure I
Y-1933096-X
F-Connector Coupler, 2 GHz; Figure E
Y-1499855-X
3.5 mm Stereo Mini-Headphone, Screw Terminal, Figure F
Y-1933582-X
Speaker Post, Black Stripe
Y-1479190-X
Speaker Post, Red Stripe; Figure G
Y-1479191-X
SC Simplex Coupler; Fiber Type: Multimode or Singlemode
Y-1499836-X
LC Coupler; Fiber Type: Singlemode APC; LC Coupler and Housing, Green
1933286-3
LC Coupler; Fiber Type: Singlemode; LC Coupler and Housing, Blue
1933286-4
LC Coupler; Fiber Type: XG LO 850 nm 50/125µm; LC Coupler and Housing, Aqua, OM3 & OM4
1933286-6
LC Coupler; Fiber Type: 50/125µm; LC Coupler and Housing, Black, OM2
1-1933286-1
LC Coupler; Fiber Type: 62.5/125µm; LC Coupler and Housing, Beige, OM1
1-1933286-2
USB A-A Coupler; Figure J
Y-1933659-X
USB B-A Coupler; Figure K
Y-1933661-X
HDMI Coupler Figure H
2111500-2
Blank Insert Figure A
Y-1116412-X
268
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Voice - Patch Panels
Category 3 Patch Panels
FEATURES:
• Meets or exceeds TIA and ISO Cat. 3 component
performance requirements
• Available in 2- through 3 -pair for voice and low speed data applications
• Fit standard 19” racks
ORDERING INFORMATION
Description
Height
Wiring Pattern
Part Number
24-Port
1U (1.75")
RJ25C (3-Pair)
558257-1
RJ14C (2-Pair)
557403-1
48-Port
2U (3.50")
RJ25C (3-Pair)
558258-1
RJ14C (2-Pair)
557411-1
RJ25C (3-Pair)
558259-1
RJ14C (2-Pair)
557415-1
96-Port
4U (7.00")
Category 3 Telephone Patch Panel - fixed
FEATURES
• 19", 1U, Telephone Panel with 50 ports
• Prepared for AMPTRAC upgrade
12. Modular Twisted Pair Cabling
• Active Pin-out: 36,45
• Enhanced 110 IDC blocks compatible with 110C
Impact or LSA-PLUS Insertion tool
• Conductor diameter range from AWG 26-22 (0.4-0.65 mm)
• Rear cable management for multipair cables
• 110 IDC blocks for conductor insulation diameters up to 1.28 mm
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Cat. 3; 50 Ports Telephone Patch Panel - fixed; 110C IDC blocks
1394060-2
Category 3 Telephone Patch Panel - sliding
FEATURES
• 19”, 1U, Telephone Panel with 25 or 50 ports
• Active Pin-out: 36,45
• Enhanced LSA-PLUS IDC blocks compatible with LSA-PLUS Insertion tool
• Expansive cable management for maximum cable protection
• Innovative sliding panel mechanism for improved ease of installation
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Cat. 3; 25 Ports Telephone Patch Panel - sliding; LSA-PLUS blocks
7022 4 001-25
Cat. 3; 50 Ports Telephone Patch Panel - sliding; LSA-PLUS blocks
7022 4 001-50
318108AE 12/13 www.te.com/enterprise-asia
269
Modular Twisted Pair
Voice - LSA-PLUS Modules
LSA-PLUS Series 2 Backmount Disconnection Module
10 pair LSA-PLUS modules which contain two piece contacts
normally closed. Has advantage of individual pair disconnection
and four wire test access.
ORDERING INFORMATION
Description
Part Number
LSA-PLUS Backmount Disconnection Module, White, Pack of 10
6089 1 102-02
LSA-PLUS Backmount Disconnection Module, Cream, Pack of 10
6089 1 810-00
LSA-PLUS PROFIL NT Disconnection Module
Disconnection module for 10 pairs, with right-angled arrangement of the
contact rows for distributor systems ensuring enhanced access security.
The mounting pitch is only 17.5mm. For installation in PROFIL rack systems
with rod spacing 95mm for 10 pairs.
Small jumper guides left and right with built-in earth contact clips.
Housing colour: cream white
12. Modular Twisted Pair Cabling
ORDERING INFORMATION
Description
Part Number
LSA-PLUS PROFIL NT Disconnection Module, 10 Pairs
7014 1 601-00
LSA-PLUS PROFIL NT Earth Module
For connecting drain wires to an earth contact without soldering,
wire-stripping or the use of screws.
Designed for universal use with:
• Up to 20 drain wires
• For clicking onto PROFIL frames
Housing colour: red
ORDERING INFORMATION
Description
LSA-PLUS PROFIL NT Earth Module
270
Part Number
7014 2 152-00
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Voice - LSA-PLUS Label Holders
10 Pair Label Holder and Labels
Easy identification of terminations and groups of modules. Label holders are
available for mounting on 10 pair LSA-PLUS modules and for mounting directly onto
the backmount frame. Labels can be ordered separately.
ORDERING INFORMATION
Description
Quantity
Part Number
Double Sided Hinged Label Holder Grey
Pack of 10
6092 1 810-00
Label Holder Complete with Label,
fits on one position on backmount frame
Pack of 10
Strips
6092 1 820-00
Blank white labels for use with label holders
6092 1 810-00 & 6092 1 840-00
Pack of 100
6534 1 001-00
PROFIL Module Label Holder
Designed for universal use with backmount frame
and PROFIL rod systems. For vertical identification
12. Modular Twisted Pair Cabling
Label size: 95 x 18 mm for 2/10
Requires the space of one connection module
in the backmount frame / PROFIL rod system.
ORDERING INFORMATION
Description
Part Number
PROFIL Module Label Holder
6753 2 009-00
LSA-PLUS NT Hinged Label Holder
Hinged label holder for LSA-PLUS NT. Can be
inserted directly onto LSA-PLUS NT/PROFIL NT modules for
10 pairs. Comes with paper label and transparent cover. The
flammability class of the grey label holder is UL94 V-0
ORDERING INFORMATION
Description
Hinged Label Holder
Part Number
7014 2 007-00
318108AE 12/13 www.te.com/enterprise-asia
271
Modular Twisted Pair
Voice - LSA-PLUS Frames
Backmount Frames
Backmount frames in a variety of sizes,
suitable for LSA-PLUS Series 2 Modules.
ORDERING INFORMATION
Description
Quantity
Part Number
11mm Deep, 1 Module
1
6424 3 005-01
11mm Deep, 2 Modules
1
6424 3 005-02
11mm Deep, 7 Modules
1
6424 3 005-07
30mm Deep, 10 Modules
1
6424 3 007-10
50mm Deep, 30 Modules
1
6424 3 009-30
60mm Deep, 34 Modules
1
6424 3 010-34
PROFIL Frame 95/46
12. Modular Twisted Pair Cabling
For installation in already set-up distribution frames and distribution cabinets.
–– The frame consists of:
2 PROFIL rods, 12mm in diameter (stainless steel)
An adequate number of PROFIL holders with
a depth of 46mm
Usable length
–– Completely assembled PROFIL frame:
PROFIL frame 95 for accommodation of LSA PROFIL modules 2/10, 2/8-95, LSA-PROFIL NT
10 pairs and HighBand®
ORDERING INFORMATION
Description
Part Number
PROFIL Frame 95/46, length of rods 299mm
6577 2 812-01
PROFIL Frame 95/46, length of rods 574mm
6577 2 812-02
PROFIL Frame 95/46, length of rods 861mm
6577 2 812-03
PROFIL Frame 95/46, length of rods 1136mm
6577 2 812-04
PROFIL Frame 95/46, length of rods 1423mm
6577 2 812-05
PROFIL Frame 95/46, length of rods 1698mm
6577 2 812-06
272
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Voice - LSA-PLUS Connection Cords
LSA-PLUS Series 2 Connection Cord
Equipped with a plug at each end of the cord. Primarily used for
interconnecting separate circuits either on the same or between
different LSA-PLUS modules.
ORDERING INFORMATION
Description
Quantity
Part Number
2 Pole. For use with LSA-PLUS connection and
disconnection modules, cord length 1.5m
Pack of 10
6529 1 022-01
4 Pole. For use with LSA-PLUS switching and
disconnection modules, cord length 1.5m
Pack of 10
6529 1 042-01
LSA-PLUS NT Connection Cord, 1 Pair
12. Modular Twisted Pair Cabling
Connection cord with 2 NT plugs. Thanks to the extended length, the
plug can be easily gripped even when there are adjacent protection
magazines. Designed for LSA-PLUS NT/LSA PROFIL NT disconnection
and switching modules; 2-pole connection on the cable side (a to a and b
to b).
ORDERING INFORMATION
Description
LSA-PLUS NT connection cord, 1 pair 2m
Part Number
7014 2 040-00
318108AE 12/13 www.te.com/enterprise-asia
273
Modular Twisted Pair
Voice - LSA-PLUS Protection Plugs
ComProtect Series B
Compact plug-in single pair overvoltage protection for
LSA-PLUS series. ComProtect Series B protects from damage caused
by overvoltage with a 3-pole GDT with failsafe (primary circuit) and
transient secondary elements (Diodes) for quick responding fine
protection. Additional overcurrent protection is realised with reversible
thermistors (PTCs) that complete the 5 point protective circuitry. These
devices are designed for use in exchanges and terminal equipment in
both analogue and ISDN (<2MBps) systems. All include earthing rail.
ORDERING INFORMATION
Description
Quantity
Part Number
CP BI12A1 – 5 point and transient protection,
max. operating voltage is 12V, GDT with failsafe
10
5909 1 084-00
CP BI24A1 – as above, max. operating voltage is 24V
10
5909 1 083-00
CP BI70A1 – as above, max. operating voltage is 70V
10
5909 1 082-00
CP BI180A1 – as above, max. operating voltage is 180V
10
5909 1 076-00
CP BOD180A2 – high GDT clamping voltage (>250V)
10
5909 1 078-10
12. Modular Twisted Pair Cabling
NTP OD180A2
Recommended for protection of distribution and terminal equipment
in analog, ISDN, HDSL and ADSL telecommunication systems.
Designed for the partial or complete equipping of LSA-PLUS NT or
LSA PROFIL NT disconnection or switching modules in conjunction
with a 10-pair earth bar (Order No.: 7019 3 037-00).
The protection circuit consists of a 3-pole overvoltage arrestor, fail-safe
contact, reversible overcurrent protection components and diodes
for secondary overvoltage protection. The overcurrent protection
functions as a reversible line fuse.
ORDERING INFORMATION
Description
NTP OD180A2
274
Part Number
7019 1 014-00
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Voice - Indoor Boxes
Connection Box 201D
Low profile plastic box accommodates up to
20 pairs or 2 LSA-PLUS modules.
Dimensions: 170(H) x 120(W) x 43(D)mm
ORDERING INFORMATION
Description
Part Number
Connection Box 201D, 20 Pair
6429 1 076-00
Connection Box 201D, 10 Pair
6429 1 078-00
Connection Box 301A
Plastic modular box, for 100 pairs designed to accommodate
10 LSA-PLUS 10 pair modules.
Dimensions: 320(H) x 210(W) x 120(D)mm
Description
12. Modular Twisted Pair Cabling
ORDERING INFORMATION
Part Number
Connection Box 301A
(Includes 1 backmount frame 5/30/10A equivalent and earthing)
6530 1 017-00
318108AE 12/13 www.te.com/enterprise-asia
275
Modular Twisted Pair
Voice - Indoor Boxes
KRONECTION Boxes
FEATURES
• Plastic Distribution Box for Surface- and flush-mounted applications
• All KRONECTION boxes (empty housing) can be
fitted with LSA-PLUS NT back-mount frames
• KRONECTION boxes with back-mount frames are designed
for installation of overvoltage protection elements
(additional wall attachment frame required)
• Protection class: IP 30 according to DIN 40050.These
distribution boxes are designed for indoor use.
• Flammability class: UL 94V-0
Color: RAL 7035 (polystyrene-compatible paintings possible).
ORDERING INFORMATION
Description
H x W x D (mm)
Part Number
KRONECTION-Box I (empty)
170 x 140 x 75
6436 1 001-xx
KRONECTION-Box I (outfitted with 1 back-mount frame for 3 LSA-PLUS modules 2/10)
170 x 140 x 75
6436 1 013-xx
Back-mount frame NT for Box I (30 pairs, without label holder)
7014 3 046-13
KRONECTION-Box II (empty)
215 x 215 x 75
6406 1 001-xx
KRONECTION-Box II (outfitted with 1 back-mount frame for 3 LSA-PLUS modules 2/10)
215 x 215 x 75
6406 1 015-xx
12. Modular Twisted Pair Cabling
Back-mount frame NT for Box II (70 pairs, without label holder)
7014 3 046-12
KRONECTION-Box III (empty)
320 x 215 x 75
6437 1 001-xx
KRONECTION-Box III (outfitted with 1 back-mount frame for 3 LSA-PLUS modules 2/10)
320 x 215 x 75
6437 1 020-xx
Back-mount frame NT for Box III (120 pairs, without label holder)
7014 3 046-11
xx = 20 for door with turnbuckle
xx = 21 for door with cylinder lock and one key
Accessories for KRONECTION-Box I, II, III
FEATURES
• Mounting frames available as flush-mount or for attachment
• Attachment frames for increasing the installation depth by 37 mm
for overvoltage protection applications
ORDERING INFORMATION
Description
Part Number
Flush-mounting frame for KRONECTION-Box I
6436 2 004-20
Attachment frame for KRONECTION-Box I
6436 3 003-20
Flush-mounting frame for KRONECTION-Box II
6406 2 004-20
Attachment frame for KRONECTION-Box II
6406 3 003-20
Flush-mounting frame for KRONECTION-Box III
6437 2 004-20
Attachment frame for for KRONECTION-Box III
6437 3 003-20
Cylinder lock for replacing the turnbuckle incl. one key
6437 2 010-00
Jumper pin as wire guide (6 pieces)
6406 2 013-00
276
www.te.com/enterprise-asia 12/13 318108AE
Flush-mounting frame
Attachment frame
Modular Twisted Pair
Voice - Indoor Boxes
LSA Connection Boxes
FEATURES
• Manufactured from lightweight 1mm
mild steel
• Removable top and bottom gland plates and internal jumper rings
• Quick release hinges
• Doors can be hinged either left or right
• Strong, robust and durable solution
• Tidy cable management
• Quick release hinges aid and simplify installations
• Increased flexibility
ORDERING INFORMATION
Description
Pairs
Capacity
Backmount
Frames
Dimensions (mm)
WxHxD
Weight
(Kg)
Jumper
rings
Pack Qty
Connection Box 500 Series
100
1 x 10 way
235x350x115
3.2
4
1
6428 2 421-00
Connection Box 500 Series
200
1 x 20 way
235x700x115
5.2
6
1
6428 2 420-00
Connection Box 500 Series
200
2 x 10 way
425x350x115
5.4
6
1
6428 2 418-00
Connection Box 500 Series
400
2 x 20 way
425x700x115
8.6
9
1
6428 2 419-00
Connection Box 510
340
1 x 34 way
300x1000x140
11
8
1
6428 2 423-00
Connection Box 520
680
2 x 34 way
500x1000x140
17
12
1
6428 2 424-00
Connection Box 530
1020
3 x 34 way
750x1000x140
25
16
1
6428 2 425-00
Connection Box 540
1340
4 x 34 way
1000x1000x140
32
20
1
6428 2 422-00
318108AE 12/13 www.te.com/enterprise-asia
277
12. Modular Twisted Pair Cabling
Part Number.
Modular Twisted Pair
Unloaded Hardware - Patch Panels
Foldable UCP Patch Panel Angled and Flushmount
Please refer to Chapter 4, page 45
Angled 1U Modular Panel (unloaded)
FEATURES
• 19" 1U angled modular Patch Panel to be
equipped with different Slim Line jacks
• Adjustable & removable rear cable bracket incl.
easy to use cable organizing CaRe-clips
• Including grounding bolt
ORDERING INFORMATION
12. Modular Twisted Pair Cabling
Description
Part Number
Angled modular panel UTP, color: black (RAL 9005)
1-1671157-1
Angled modular panel STP, color: black (RAL 9005)
1-1671157-2
Multimedia SL Series Patch Panels (unloaded)
FEATURES:
• Accepts AMP-TWIST, shielded, and unshielded SL Series Jacks and inserts
• May be used to create custom configurations –
including mixing fiber, twisted-pair, coax and A/V applications
• Ports may be individually replaced
• Angled versions allow elimination of horizontal cable management
for higher rack densities and ease of cable dress
ORDERING INFORMATION
Description
Height
Width
12-Port
1U (1.75")
19.0"
Straight
–
1933412-1
24-Port
1U (1.75")
19.0"
Straight
–
1933307-1
Angled
–
1933309-1
48-Port
2U (3.50")
19.0"
Straight
A
1933308-1
Angled
B
1933310-1
278
Figure
Part Number
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Unloaded Hardware - Patch Panels
Flushmount AMPTRAC Ready! Patch Panel (unloaded)
FEATURES
• 19" 1U unloaded flushmount panel to be equipped with different
SlimLine jacks
• AMPTRAC Ready! version: prepared for AMPTRAC upgrade
• Holds up to 24 SL jacks
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
AMPTRAC Ready! unloaded panels for all SL jacks;
Color: black (RAL 9005)
1711685-1
AMPTRAC Ready! unloaded panels for all SL jacks;
Color: light gray (RAL 7035)
1711685-2
Flushmount Modular Patch Panel (unloaded)
FEATURES
• 19" 1U unloaded flushmount panel to be equipped with different
SlimLine jacks
12. Modular Twisted Pair Cabling
• Suitable for UTP and STP SL Series jacks
• Including grounding bolt
Color: black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Flushmount Modular Panel
1-1671183-1
Flushmount Standard Patch Panels (unloaded)
FEATURES
• 19" Standard unloaded flushmount panel to be equipped with different
SlimLine jacks
• Accepts up to 24 SL jacks
• Including grounding bolt
ORDERING INFORMATION
Description
Part Number
24 port panel; Height: 1U; Color: black (RAL 9005)
336526-1
24 port panel; Height: 1U; Color: light gray (RAL 7035)
336526-4
318108AE 12/13 www.te.com/enterprise-asia
279
Modular Twisted Pair
Unloaded Hardware - Patch Panels
Modular Patch Panel with Shutter (unloaded)
FEATURES:
• 19" 1U unloaded patch panel to be equipped with SlimLine
jacks
• Holds up to 24 SL jacks
A
• Optional rear cable support bar (sold separately)
Color: Black
B
ORDERING INFORMATION
Description
Figure
Part Number
Angled Patch Panel with Shutter (for Un-shielded solution, unshielded)
A
1859181-1
Straight Patch Panel with Shutter (for Un-shielded solution, unshielded)
B
1427016-2
Rear Cable support bar
–
84841-1
Angled Patch Panel with Shutter (for Shielded solution, shielded)
12. Modular Twisted Pair Cabling
280
www.te.com/enterprise-asia 12/13 318108AE
1859182-1
Modular Twisted Pair
Unloaded Hardware - Patch Panels
Modular Q-Jack Patch Panel (unloaded)
FEATURES
• 19” unloaded 1U flushmount patch panel
to be used with Q-Jacks (see page 208)
• UTP and STP configuration possible
• Integral cable management bar
• 45° IDC contacts providing secure, gas-tight
connections
• Accepts 110 style termination tools
• Universal 568A/B wiring
• Discrete labelling system
ORDERING INFORMATION
Description
Part Number
24 port Q-Jack Patch Panel (unloaded)
300001739943
48 port Q-Jack Patch Panel (unloaded)
300001739995
Blank plugs 12 per pack
300001741753
12. Modular Twisted Pair Cabling
Modular KM8 Jack Patch Panel (unloaded)
FEATURES
• 19” unloaded 1U flushmount patch panel to be used
with KM8 Jacks (see pages 207, 212 and 214)
• UTP and STP configuration possible
• Integral cable management bar
• KM8 termination tool
• Discrete labelling system
ORDERING INFORMATION
Description
Part Number
24 port KM8 Patch Panel (unloaded)
7022 2 155-24
32 port KM8 Patch Panel (unloaded)
7022 2 155-32
318108AE 12/13 www.te.com/enterprise-asia
281
Modular Twisted Pair
Unloaded Hardware - Consolidation Box
Quick-Fit Consolidation Point Box
FEATURES
• Wall mount or raised floor use
• Hinged cover with knurled screw
• Low profile (H = 56mm)
• High flexibility, accepts copper and fiber Quick-Fit modules and/or cassettes
• Installer friendly
• Dust resistant
• Easy access for cleaning fiber optic connectors
• Robust construction
• Integrated strain relief feature
• Including grounding bolt
Color: Black (RAL 9005)
ORDERING INFORMATION
Description
Part Number
Quick-Fit Consolidation Point Box
1-1671414-1
12. Modular Twisted Pair Cabling
Unloaded Copper Quick-Fit Modules
• To be equipped with six SL Jacks
• Available for STP and UTP
• Automatic bonding by design
• Labels included
ORDERING INFORMATION
Description
Part Number
STP Quick-Fit module
2111093-1
UTP Quick-Fit module
2111117-1
Blank Quick-Fit module
1479698-1
282
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Unloaded Hardware - Faceplates
British Style Angled, Shuttered Faceplate
FEATURES:
• “Decorator” BS Angled Faceplate
• Dimension: 86mm X 86mm BS
• Spring loaded, transparent shutter
• Detachable front cover
• Accepts Most SL / AMP-TWIST Series Jacks*
• Colour: White
• Screws and label holder included
ORDERING INFORMATION
Description
Part Number
Single Port, unloaded
1859167-1
Dual Port, unloaded
1859168-1
* except 110Connect Cat 5e Shielded Jack
British Style Standard Faceplate
12. Modular Twisted Pair Cabling
FEATURES
• BS Standard Faceplate
• Dimension: 86mm X 86mm BS
• Spring loaded Shutter
• Accepts all SL / AMP-TWIST Series Jacks
• Colour: White
• Screws and label holder included
ORDERING INFORMATION
Description
Part Number
Single Port, unloaded
1859049-1
Dual Port, unloaded
1859050-1
Quad Port, unloaded
1859053-1
318108AE 12/13 www.te.com/enterprise-asia
283
Modular Twisted Pair
Unloaded Hardware - Outlets 80 x 80 mm (DIN)
BS LJ6C Unloaded Faceplates and Shuttered Modules
FEATURES
• Unloaded faceplate accepts either 1 or 2 LJ6C shuttered modules
• Dimensions faceplate: 86 x 86 mm (single and dual port)
• Single shuttered LJ6C module (spring loaded shutter)
• Dimensions module 25 x 39 mm
Color: signal white (RAL 9003)
ORDERING INFORMATION
Description
Part Number
Single port LJ6C unloaded faceplate
1711301-1
Dual port LJ6C unloaded faceplate
1711302-1
Quad port LJ6C unloaded faceplate
2153004-1
Single shuttered LJ6C module
1711348-1
Blanking plate
1711491-1
Single unshuttered angled LJ6C module
1711775-1
Single shuttered angled LJ6C module
1859096-1
Keystone UK Style Faceplate
12. Modular Twisted Pair Cabling
FEATURES
• UK style faceplate with integrated dust protection
• For accommodating Category 5e HK and
Category 6 KM8 and keystone jacks
• Dimensions: 85 x 85mm
ORDERING INFORMATION
Description
Part Number
Unloaded Faceplate, Keystone, UK Style, White, Single
6538 3 111-03
Unloaded Faceplate, Keystone, UK Style, White, Double
6538 3 111-04
Note: Unloaded faceplates compatible with HK jacks:
Cat 5e HK UTP Pure White (6540 1 130-01)
Cat 5e HK UTP Black (6540 1 130-04)
Cat 5e HK STP Metal (6540 1 154-02)
284
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Unloaded Hardware - Outlets Single/Double Gang (US Installation)
Standard USA Faceplates
FEATURES
• Accepts all AMP-TWIST jacks, SL Series jacks, MT-RJ outlet jacks and
SL Series inserts
• Faceplate dimensions:
2.75 in (69.85 mm) x 4.5 in (114.30 mm) x 0.22 in (5.59 mm)
• Label viewing area with
integrated label covers that flip down and Snap-in place
• Extender kits are used to add 0.5 inches of space between the mounting surface and the faceplate
ORDERING INFORMATION
Description
Part Number
Port Count: 1; Single Gang; Orientation: Vertical
2111008-1
Port Count: 2; Single Gang; Orientation: Vertical
2111009-1
Port Count: 3; Single Gang; Orientation: Vertical
2111010-1
Port Count: 4; Single Gang; Orientation: Vertical
2111011-1
Port Count: 6; Single Gang; Orientation: Vertical
2111012-1
Port Count: 6; Double Gang; Orientation: Vertical
2111013-1
Port Count: 8; Double Gang; Orientation: Vertical
2111014-1
Port Count: 12; Double Gang; Orientation: Vertical
2111015-1
Extender Kit
2111201-1
Port Count: 4; Single Gang; Orientation: Horizontal
2111203-1
Y- -X
Color
0- -1
Almond
0- -2
Black
0- -3
White
0- -4
Gray
1- -1
Electrical
Ivory
12. Modular Twisted Pair Cabling
Surface Boxes
FEATURES
• Back Box for Surface Mounting
• 44.5 mm depth and one piece construction simplifies installation
ORDERING INFORMATION
Description
Part Number
Single Gang; almond
558251-1
Single Gang; pure white
558251-3
318108AE 12/13 www.te.com/enterprise-asia
285
Modular Twisted Pair
Unloaded Hardware - Surface Mount Boxes
Surface Mount Modules and Accessories
FEATURES
A
B
C
D
• Accept AMP-TWIST modular jacks
and all SL Series modular
jacks and inserts
• Can accommodate fiber cable and connectors
(MT-RJ, LC, simplex SC, and ST) and
includes fiber loop management
• Allows access to jacks and inserts
while module is mounted
• Cable exits located on rear, bottom
and both sides of modules Features cable entry strain relief
• Provided with label and clear label cover, squares of doublesided foam tape, self-tapping screws, and cable ties
ORDERING INFORMATION
12. Modular Twisted Pair Cabling
Description
Part Number
Surface Mount Module; 2-Port; Figure A
Y-1933668-X
Surface Mount Module; 4-Port; Figure B
Y-1933671-X
Surface Mount Module; 6-Port; Figure C
Y-1933674-X
Magnet for Metal Surface Mounting; Figure D
1933677-1
Modular Jack Boxes
FEATURES
• Accepts unshielded Standard 110Connect, any SL Series Jacks and MT-RJ
• Very compact
• Individual outlets are icon-able
• Patented invisible icon holes remain invisible when not used ORDERING INFORMATION
Description
Part Number
1 Port; almond
1116697-1
1 Port; pure white
1116697-3
2 Port; almond
1116698-1
2 Port; pure white
1116698-3
286
www.te.com/enterprise-asia 12/13 318108AE
Y- -X
Color
0- -1
Almond
0- -2
Black
0- -3
White
0- -4
Gray
1- -1
Electrical
Ivory
Modular Twisted Pair
Unloaded Hardware - Surface Mount Boxes
AMP-TWIST SL Jack Office Boxes
FEATURES
• Accepts AMP-TWIST jacks and all SL series jacks
• Compatible with most trunking
• High density
• Individual outlets are icon-able
• Patented invisible icon holes remain invisible when not used
ORDERING INFORMATION
Description
Part Number
2 Port; Color: almond
1933287-1
2 Port; Color: black
1933287-2
2 Port; Color: pure white
1933287-3
4 Port; Color: almond
1933288-1
4 Port; Color: black
1933288-2
4 Port; Color: pure white
1933288-3
12. Modular Twisted Pair Cabling
Surface Mount Boxes
FEATURES
• Dimensions enable it to be used in restricted spaces
• Flammability class: UL94 V0
ORDERING INFORMATION
Description
Part Number
Surface Mount, unloaded for KM8, 1port
7080 2 064-10
Surface Mount, unloaded for KM8, 2port
7080 2 065-10
RJ-45 Dust Cap
FEATURES
• Re-usable rubber dust caps
• Fits in all RJ 45 Jacks
• Available in 7 colors
ORDERING INFORMATION
Description
RJ-45 dust cap
Part Number
Y-969556-X
318108AE 12/13 www.te.com/enterprise-asia
Y- -X
Color
0- -1
Red
0- -2
Yellow
0- -3
Green
0- -4
Blue
0- -5
Black
0- -6
Gray
0- -7
White
287
Modular Twisted Pair
Twisted Pair Tools
AMP-TWIST & SL Series Modular Jack
Termination Tool Kit
FEATURES
• Terminates all AMP-TWIST and SL Series Modular Jacks
• Strips cable, marks foil, terminates and cuts 8 conductors at once
• Maintains twisted pair integrity
• Reliable connections every time
• Time and cost saving simplifying lacing process
and speeding up the termination
• Lacing fixture assures simple and efficient use
(not used for AMP-TWIST Jacks)
ORDERING INFORMATION
Description
Part Number
Handheld termination tool kit with lacing fixture
1725150-1
Handheld termination tool kit without lacing fixture (for AMP-TWIST jacks)
1725150-3
Lacing fixture - Spare Part
1673956-1
110C Impact Tools
12. Modular Twisted Pair Cabling
FEATURES
• Industry standard termination tools for SL Modular, 110Connect,
AMP CO Ultra and other LSA-PLUS compatible IDC blocks
• Available as impact tool (premium or standard version) or as
non-impact tool
• Tools are delivered with blade
• Extended-life blades have a lifetime three times longer than standard blades
ORDERING INFORMATION
Description
Part Number
Premium Impact Tool with Extended-Life Blade
1375308-1
Standard Impact Tool with Standard Blade
1583608-1
Non-Impact Tool with Standard Blade
1583236-1
Replacement Blade (Extended-Life)
1375309-1
Replacement Blade (Standard)
1375310-1
288
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Twisted Pair Tools
Economical Low Profile SL Termination Tool
FEATURES
• Terminates shielded and unshielded SL modular jacks
• Terminates and cut 8 conductors at once
• Maintains twisted pair integrity with lacing fixture
• Reliable connection very time
• Time and cost saving simplifying
lacing process and speeding up the termination
• High quality plastic material
ORDERING INFORMATION
Economical Low Profile SL Termination Tool Kit
Part Number
1859606-1
12. Modular Twisted Pair Cabling
Description
318108AE 12/13 www.te.com/enterprise-asia
289
Modular Twisted Pair
Twisted Pair Tools
Cable Preparation Tools
FEATURES
• Easy, safe and fast cable preparation
• Diagonal Cutter for precise cutting of wire
• JacKnack cuts the cable sheath
• LightKnack is designed to provide light anywhere
ORDERING INFORMATION
Description
Part Number
Diagonal Cutter
1116571-1
JacKnack
2119000-1
LightKnack
2119700-1
Q-Jack Punchdown Pad
FEATURES
• Q-Jack Punchdown Pad helps the termination process
• Q-Jack Punchdown Pad also support RJ45 UTP Modular Jacks
12. Modular Twisted Pair Cabling
ORDERING INFORMATION
Description
Part Number
Q-Jack Punchdown Pad (Pack of 10)
6537 1 610-00
LSA-PLUS Insertion Tool
FEATURES
• For termination of wires with the conductor diameter
range 0.35 - 0.9mm and overall diameter range 0.7 - 2.6mm
• Insert and cut wires simultaneously
• Insertion sensor ensures the conductor is fully inserted into the
block contacts before allowing any excess wire to be cut off
• An inhibitor lock prevents the scissors from operating, particularly useful in
applications in which conductors are daisy-chained through several contacts
• Specially designed wire hook removes terminated conductors
• Blade helps to remove blocks easily from back mount frames
ORDERING INFORMATION
Description
LSA-PLUS Insertion Tool
290
Part Number
6417 2 055-01
www.te.com/enterprise-asia 12/13 318108AE
Modular Twisted Pair
Twisted Pair Tools
KM8 Termination Tool
FEATURES
• Tool for swift terminating KM8 style jacks
• Hundreds of KM8 jack terminations from one tool
ORDERING INFORMATION
Description
Part Number
KM8 Termination Tool
6830 1 490-00
Multimate termination Tool
FEATURES
• Terminates RJ45 UTP Modular Jack ensuring a significant saving of
installation time
• Inserts and crops wire simultaneously in one single handed easy action
12. Modular Twisted Pair Cabling
• Replacement blade units can be purchased and
replaced without the need for special tooling
• Carry pouch with belt loop helps conveniently store
and protect the tool and its contents
ORDERING INFORMATION
Description
Part Number
Multimate Termination Tool Pack
6467 1 140-00
Replacement Head, C6A Keystone (White)
6467 2 142-00
Replacement Blade Unit
6467 2 149-00
318108AE 12/13 www.te.com/enterprise-asia
291
292
www.te.com/enterprise-asia 12/13 318108AE
13. Home Net-works Residential Cabling
Enclosures & Panels.......................................................................................294
Modules............................................................................................................... 295
Connectivity......................................................................................................296
Accessories........................................................................................................298
318108AE 12/13 www.te.com/enterprise-asia
293
Home Net-Works Residential Cabling
Enclosures & Panels
Home Net-Works Enclosures Surface Mount
FEATURES
• Aesthetic surface mount enclosure
• Solid steel construction with hingeable cover
• Knockout ports for cable entry on top and bottom
• 1" x 1" mounting grid for maximum versatility
• Accommodates multiple 18-Port connectivity panels
• Including grounding bolt
ORDERING INFORMATION
Description
Color
Part Number
Home Net-Works Enclosure Small
White (RAL 9003)
1-1671331-1
Home Net-Works Enclosure Large
White (RAL 9003)
1-1671331-2
Home Net-Works Enclosures Flush Mount
FEATURES
• Aesthetic flush mount enclosure with cover (all AWG 20 steel)
• Multiple double knockouts for cable entry on all surfaces
13. Home Net-works Residential Cabling
• Multiple cable tie tabs for cable management
• 1" x 1" mounting grid for maximum versatility
• Recess or surface option
• Dual knockouts for electrical j-box
• Accommodates multiple 18-Port connectivity panels
ORDERING INFORMATION
Description
Color
Part Number
14" Enclosure with Cover
White
1933691-1
28" Enclosure with Cover
White
1933692-1
Connectivity Panels
FEATURES
• Inclined panel accepting up to 3 x 6-port modules
• Available for UTP and STP
• STP version including a PEC and grounding point
ORDERING INFORMATION
Description
Color
Angled Bracket STP
Black (RAL 9005)
1933776-1
Angled Bracket UTP
Black (RAL 9005)
1933693-1
294
Part Number
www.te.com/enterprise-asia 12/13 318108AE
Home Net-Works Residential Cabling
Modules
AMP CO Ultra Quick-Fit Kit
FEATURES
• Fast termination and easy assembly
• Shielded housing with patented automatic shielding clamp
• Kit includes 2 die-cast housings, 2 AMP CO Plus Edge Connectors
and frame for labeling. (AMP CO Inserts to be ordered separately)
• Performance up to 2.0 GHz
ORDERING INFORMATION
Description
Color
Part Number
AMP CO Ultra Quick-Fit Kit; (RAL 9005)
Black
2153014-1
Standard Telecom Bridge
FEATURES
• 6 Ports - 4 lines per port
• For basic telephone, fax and dial-op modem service
• Bridge for incoming lines to six output ports
Description
Front-Loadable Standard Telecom Bridge
13. Home Net-works Residential Cabling
ORDERING INFORMATION
Part Number
1479701-1
Unloaded Connectivity Module
FEATURES
• 6 port module, accepts all SL series jacks
• Available for UTP and STP
ORDERING INFORMATION
Description
Part Number
Connectivity Module STP
2111093-1
Connectivity Module UTP
2111117-1
Blank module
1479698-1
318108AE 12/13 www.te.com/enterprise-asia
295
Home Net-Works Residential Cabling
Connectivity
SL Series Multimedia Inserts
FEATURES
• The inserts offer flexibility and density at the work area outlet
Y- -X
Color
0- -1
Light Almond
• Can be installed in any faceplate or outlet designed to the SL series jack footprint
0- -2
Black
• Some couplers may not be available in all colors
1- -3
Alpine White
ORDERING INFORMATION
13. Home Net-works Residential Cabling
Description
Part Number
ST Coupler; Fiber Type: Multimode
Y-1339123-X
ST Coupler; Fiber Type: Singlemode
Y-1479181-X
BNC Coupler Insert; Figure B
Y-2111615-X
MT-RJ SL Series Housing
Y-1374416-X
RCA Coupler, Red Dielectric
Y-1375361-X
RCA Coupler, White Dielectric
Y-1375362-X
RCA Coupler, Yellow Dielectric
Y-1375363-X
RCA Solder Termination, Red Dielectric
Y-1375364-X
RCA Solder Termination, White Dielectric
Y-1375365-X
RCA Solder Termination, Yellow Dielectric
Y-1375366-X
RCA Coupler, Green Dielectric
Y-1933192-X
RCA Coupler, Blue Dielectric
Y-1933193-X
RCA Coupler, Orange Dielectric
Y-1933194-X
RCA to F-Connector; Figure I
Y-1933096-X
F-Connector Coupler, 2 GHz; Figure E
Y-1499855-X
3.5 mm Stereo Mini-Headphone, Screw Terminal, Figure F
Y-1933582-X
Speaker Post, Black Stripe
Y-1479190-X
Speaker Post, Red Stripe; Figure G
Y-1479191-X
SC Simplex Coupler; Fiber Type: Multimode or Singlemode
Y-1499836-X
LC Coupler; Fiber Type: Singlemode APC; LC Coupler and Housing, Green
1933286-3
LC Coupler; Fiber Type: Singlemode; LC Coupler and Housing, Blue
1933286-4
LC Coupler; Fiber Type: XG LO 850 nm 50/125µm; LC Coupler and Housing, Aqua, OM3 & OM4
LC Coupler; Fiber Type: 50/125µm; LC Coupler and Housing, Black, OM2
1933286-6
1-1933286-1
LC Coupler; Fiber Type: 62.5/125µm; LC Coupler and Housing, Beige, OM1
1-1933286-2
USB A-A Coupler; Figure J
Y-1933659-X
USB B-A Coupler; Figure K
Y-1933661-X
HDMI Coupler Figure H
2111500-2
Blank Insert Figure A
Y-1116412-X
H
296
PJ
www.te.com/enterprise-asia 12/13 318108AE
Home Net-Works Residential Cabling
Connectivity
SL Series Multimedia Jacks
FEATURES
• For use when distances are less than 130 ft.
• Uses Standard 110 Termination and will
accept 26-22 AWG conductors
• RCA Multimedia Jack
−− For audio and visual signals
−− Uses one pair of twisted-pair-cable white,red
or yellow dielectrics to match home theater equipment
• S-Video Multimedia Jack
−− For S-Video Y/C (Luminance/Chrominance black
and white/Color) signals
−− Uses two pairs of a standard twisted-pair cable
ORDERING INFORMATION
Description
S-Video
Part Number
Y- -X
Color
0- -1
Light Almond
1- -3
Alpine White
1375149-2
Y-1479230-X
RCA to 110 Punch Down, White Dielectric
Y-1479231-X
RCA to 110 Punch Down, Yellow Dielectric
Y-1479232-X
13. Home Net-works Residential Cabling
RCA to 110 Punch Down, Red Dielectric
318108AE 12/13 www.te.com/enterprise-asia
297
Home Net-Works Residential Cabling
Accessories
Velcro Cable Ties FEATURES
• Hook and loop ties
• No risk of damaging cables
• Releasable and reusable
• An order quantity of one equals one roll of 10 ties
ORDERING INFORMATION
Description
Part Number
Velcro Tie 1" x 8" (10pcs.)
1375253-2
Velcro Tie 1" x 12" (10pcs.)
1375254-2
Accessories
FEATURES
• Demarcation bracket: SL Series bracket accepts 2 SL Series
jacks for incoming data service demarcation
• Velcro Hold-Down Bracket: Used to secure network
electronics such as cable/DSL routers<
• Network Shelf: Accommodates network electronics such as
DSL modems, routers and switches
13. Home Net-works Residential Cabling
ORDERING INFORMATION
Description
Part Number
Dual Demarcation Bracket
1479441-1
Velcro Hold-Down Bracket
1479440-1
Network Shelf
1479437-1
298
www.te.com/enterprise-asia 12/13 318108AE
14. Commercial and Industrial Ethernet LAN
Power-over-Ethernet.................................................................................... 300
LAN Media Converters...................................................................................301
Industrial Media Converters........................................................................303
Industrial Switches......................................................................................... 304
318108AE 12/13 www.te.com/enterprise-asia
299
Commercial and Industrial Ethernet LAN
Power-over-Ethernet
8 Port Modular PoE Gigabit Midspan Unit
FEATURES
• 8 Port PoE Midspan Unit
• 19” rack mountable (with mounting frame)
• Universal 110/220V (50/60Hz) power supply
• Full power on every port (15.4 W)
• Up to 3 devices can be mounted into a 19”, 1U mounting frame
ORDERING INFORMATION
Description
Part Number
19", mounting frame 1U for 3 Midspans units
1591185-0
8 Port PoE Midspan unit; Power Cord for Europe
1591188-2
8 Port PoE Midspan unit; Power Cord for UK/Ireland
1591188-7
14. Commercial and Industrial Ethernet LAN
300
www.te.com/enterprise-asia 12/13 318108AE
Commercial and Industrial Ethernet LAN
LAN Media Converters
Ethernet Media Converter
FEATURES
• 10 Slot 19” Rack Mount Chassis System
• Supports up to 10 Media Converters
• Different Media Converter types can be mixed
• Hot-Swappable Converters
• A second power supply can be fitted
• Exceptionally reliable dual redundant power system can be HotSwapped
• Dimensions: 440 x 226 x 133 mm (W x D x H)
• Internal cooling fan
• Includes kit for mounting in 19” racking
ORDERING INFORMATION
Description
Part Number
10 Slot Chassis System with 1 Power Unit; Europe
1591032-2
10 Slot Chassis System with 1 Power Unit; UK/Ireland
1591032-7
Spare/Redundant AC Power Unit for Chassis
1591034-0
10/100 MBit/s Ethernet Media Converter
14. Commercial and Industrial Ethernet LAN
FEATURES
• 10/100 MBit/s RJ-45 Copper port
• Auto-MDI/MDI-X detection
• 100Base-FX fiber port
• Dimensions: 85 x 120 x 26 mm (W x D x H)
ORDERING INFORMATION
Description
Part Number
10/100M Multimode SC Media Converter; Europe
1591024-2
10/100M Multimode SC Media Converter; UK/Ireland
1591024-7
10/100M Multimode ST-Style Media Converter; Europe
1591026-2
10/100M Multimode ST-Style Media Converter; UK/Ireland
1591026-7
10/100M Singlemode - Single Fiber WDM 1550 nm Converter; Europe
1591029-2
10/100M Singlemode - Single Fiber WDM 1550 nm Converter;UK/Ireland
1591029-7
10/100M Singlemode SC Media Converter; Europe
1591030-2
10/100M Singlemode SC Media Converter; UK/Ireland
1591030-7
10/100M Singlemode - Single Fiber WDM 1310 nm Converter; Europe
1591031-2
10/100M Singlemode - Single Fiber WDM 1310 nm Converter; UK/Ireland
1591031-7
318108AE 12/13 www.te.com/enterprise-asia
301
Commercial and Industrial Ethernet LAN
LAN Media Converters
Gigabit Ethernet Media Converter
FEATURES
• 10/100/1000 MBit/s RJ-45 Copper port
• Auto-MDI/MDI-X detection
• 1000Base-SX or 1000Base-LX fiber port
• Dimensions: 85 x 120 x 26 mm (W x D x H)
ORDERING INFORMATION
Description
Part Number
1000Base-SX (multimode) Media Converter; Europe
1591020-2
1000Base-SX (multimode) Media Converter; UK/Ireland
1591020-7
1000Base-LX (singlemode) Media Converter; Europe
1591022-2
1000Base-LX (singlemode) Media Converter; UK/Ireland
1591022-7
14. Commercial and Industrial Ethernet LAN
302
www.te.com/enterprise-asia 12/13 318108AE
Commercial and Industrial Ethernet LAN
Industrial Media Converters
Industrial Copper-to-Fibre Media Converter
FEATURES
• Suitable for plant rooms, factory floor, oil and gas terminal
rail and marine and many more harsh environments
• Provides High / low temperature range with rugged
construction Compact housing, 140 x 30 x 95 mm
• IP30 protection
• Store-and-Forward Switching Architecture
• RJ-45 port support MDI/MDI-X auto-crossover
• Autonegotiation Speed, Half/Full Duplex
• Signal indicating LEDs
• Built-In Link Lose Forwarding (LLF) & Link Fault
Pass-Through (LFP) Technology
• Redundant wide range power input +12 to +48 V DC
• Flexible mounting: DIN-rail and panel mounting
• Operating Temperatures –40°C up to +75 °C
ORDERING INFORMATION
Description
Part Number
1987152-2
14. Commercial and Industrial Ethernet LAN
10/100 Multimode Ethernet Media converter- TEC-100-MM-XE
318108AE 12/13 www.te.com/enterprise-asia
303
Commercial and Industrial Ethernet LAN
Industrial Switches
Fast Ethernet Industrial Switches (Unmanaged)
FEATURES
• Suitable for factories, rail and road side deployment
• Compact housing, 140 x 30 x 95 mm
• IP30 protection
• Relay output
• Store-and-Forward Switching Architecture
• RJ-45 port support MDI/MDI-X
• Broadcast storm protection
• Embedded switch controller
• supports auto negotiation
• Signal indicating LEDs
• Network Cable Redundant wide range power input +12 to +48 V DC
• Flexible mounting: DIN-rail and panel mounting
• Operating Temperatures –40°C up to +75 °C
ORDERING INFORMATION
Description
Part Number
4 Port 10/100 Ethernet Switch with single MM SC Uplink Port – TES-401-MM-XE
1987033-2
5 Port 10/100 Ethernet Switch --TES-500-XE
1987031-2
8 Port 10/100 Ethernet Switch – TES 800-XE
1987032-2
14. Commercial and Industrial Ethernet LAN
Gigabit Ethernet Industrial Switches (Unmanaged)
FEATURES
• Suitable for factories, rail and road side deployment
• Compact housing, 140 x 30 x 95 mm
• IP30 protection
• Relay output
• Store-and-Forward Switching Architecture
• RJ-45 port support MDI/MDI-X
• Broadcast storm protection
• Embedded switch controller
• Supports auto negotiation
• Signal indicating LEDs
• Network Cable Redundant wide range power input +12 to +48 V DC
• Flexible mounting: DIN-rail and panel mounting
• Operating Temperatures –40°C up to +75 °C
ORDERING INFORMATION
Description
Part Number
4 Port 10/100/1000 Ethernet Switch with single SFP Uplink Port – TES-4001-SFP-XE
1987155-2
8 Port 10/100/1000 Ethernet Switch – TES 8000-XE
1987154-2
304
www.te.com/enterprise-asia 12/13 318108AE
Commercial and Industrial Ethernet LAN
Industrial Switches
10/100 Managed Industrial Switches (with Gigabit Uplink)
FEATURES
• Layer 2
• Gigabit Uplink: 2 Ports RJ-45 / SFP fiber
• Combo function (SFP or Gigabit Copper)
• Robust housing, 152 x 72 x 106 mm
• IP30 protection
• Relay output
• Store-and-Forward Switching Architecture
• RJ-45 port support MDI/MDI-X
• Signal indicating LEDs
ORDERING INFORMATION
Description
Part Number
1987256-2
8 Port 10/100 Ethernet Switch with Dual SFP Uplink Combo ports – TES-802M-GU-SFP-CO
1987257-2
14. Commercial and Industrial Ethernet LAN
16 Port Unmanaged 10/100 Ethernet With Dual SFP Uplink Combo ports- - TES 162M-GU-SFP-COMBO
318108AE 12/13 www.te.com/enterprise-asia
305
306
www.te.com/enterprise-asia 12/13 318108AE
15. Administration & Labeling
Icons......................................................................................................................308
Printer Labels....................................................................................................309
Quick-Fit Port Labels.....................................................................................310
318108AE 12/13 www.te.com/enterprise-asia
307
Administration & Labeling
Icons
Icons
FEATURES
• Icons for port identification applicable to various faceplates
of 110Connect and AMP CO series
• Different colors and different symbols available
ORDERING INFORMATION
Description
Part Number
Y- -X
Color
0- -1
Almond
0- -2
Red
0- -3
Green
0- -4
Blue
0- -5
Yellow
16 x data
Y-558198-X
16 x phone
Y-558199-X
0- -6
Black
Y-558821-X
0- -7
Orange
0- -8
White
0- -9
Violet
1- -0
Gray
16x neutral; available in -1, -6, -8 and 1- -0
4x neutral, 2x Cat. 5E, 2x Cat. 6 and 1x V1, V2, V3, V4, D1, D2, D3, D4
Y-1375092-X
Printer Labels for AMP CO Installation Kits
FEATURES
• Self-adhesive A4 sheets with printer labels for AMP CO Installation Kits
• Uses standard MS Excel sheet
ORDERING INFORMATION
Description
Part Number
Labels (6 x 32 mm, 170 pcs per sheet); Packaging 10 sheets
969704-1
15. Administration & Labeling
308
www.te.com/enterprise-asia 12/13 318108AE
Administration & Labeling
Printer Labels
Patch Panel Labels
FEATURES
• Labels are designed to fit AMP NETCONNECT and similar patch panels
• Card stock labels are perforated and compatible
with inkjet and laser printers
• Self-adhesive polyester labels are pre-cut and
compatible with laser printers
• Labels are supplied on 8.5” x 11” (21,6 x 27,9 cm) sheets
• Special 0.25” (6,4 mm) high label is provided
for use when icons are also desired
• For use with 110Connect and SL-style panels
ORDERING INFORMATION
Description
Part Number
Self-adhesive Polyester; Label Size (w x h): 3.10" x 0.50" (7.9 x 1.3 cm);
Labels per Sheet: 36; Standard Package: 5 sheets (180 labels)
1375352-1
Self-adhesive Polyester (also for use with 110Connect Office Box, 2 Port und 4 Port); Label
Size (w x h): 3.30" x 0.25" (8.4 x 0.6 cm); Labels per Sheet: 72; 5 Sheets (360 labels)
1375353-1
Labels for Cable and Cable-Assemblies
FEATURES
• Labels are designed for use on cable and cable assemblies
• Labels are pre-cut and compatible with laser printers
ORDERING INFORMATION
Description
Part Number
1479002-1
Self-adhesive Polyester 25-Pair Cable; Label size (w x h): 0.984" x 2.480" (2.5 x
6.3 cm); Labels per Sheet: 24; Standard Package: 5 sheets (120 labels)
1479003-1
15. Administration & Labeling
4-Pair Cable; Label size (w x h): 0.984" x 1.496" (2.5 x 3.8 cm); Labels
per Sheet: 48; Standard Package: 5 sheets (240 labels)
318108AE 12/13 www.te.com/enterprise-asia
309
Administration & Labeling
Quick-Fit Port Labels
Port ID labels for Quick-Fit modules and cassettes
FEATURES
• Number identification of ports
• MOQ = 100 pcs
ORDERING INFORMATION
Description
Part number
Port ID label 1...6
1933140-1
Port ID label 7...12
1933140-2
Port ID label 13...18
1933140-3
Port ID label 19...24
1933140-4
Port ID label 1/2...11/12
1671415-1
Port ID label 13/14...23/24
1671415-2
Port ID label 25/26...35/36
1671415-3
Port ID label 37/38...47/48
1671415-4
15. Administration & Labeling
310
www.te.com/enterprise-asia 12/13 318108AE
Index
Part Number Index.......................................................................................... 312
Reliable Performance.................................................................................... 325
318108AE 12/13 www.te.com/enterprise-asia
311
Index
Part Number Index
Part Number
Page
1
1-1375014-3............................................232
1-1591360-1............................................113
1-1591363-0............................................113
1-1591364-0............................................113
1-1657014-7............................................128
1-1671136-3............................................120
1-1671136-4............................................120
1-1671143-1.............................................. 28
1-1671157-1............................................278
1-1671157-2............................................278
1-1671183-1............................................279
1-1671187-1............................................120
1-1671205-4.................................................8
1-1671205-6.................................................8
1-1671206-4.................................................8
1-1671206-6.................................................8
1-1671207-4.................................................8
1-1671207-6.................................................8
1-1671209-3............................................115
1-1671209-4............................................115
1-1671226-5.................................................4
1-1671227-5.................................................4
1-1671228-3.................................................4
1-1671229-5............................................115
1-1671260-1............................................166
1-1671330-1.............................................. 39
1-1671331-1............................................294
1-1671331-2............................................294
1-1671373-1............................................165
1-1671414-1............................................136
1-1671414-1............................................282
1-1671436-1.............................................. 17
1-1671436-1............................................164
1-1671437-1.............................................. 17
1-1671437-1............................................165
1-1671547-1.............................................. 46
1-1671548-1.............................................. 46
1-1671549-1.............................................. 46
1-1671603-1.............................................. 47
1-1671603-2.............................................. 47
1-1671603-3.............................................. 47
1-1671603-4.............................................. 47
1-1671618-1.............................................. 48
1-1711481-6............................................205
1-1711481-7............................................205
1-1711481-8............................................205
1-1711481-9............................................205
1-1711691-6............................................213
1-1711691-6............................................228
1-1711691-7............................................213
1-1711691-7............................................228
1-1711691-8............................................213
1-1711691-8............................................228
1-1711691-9............................................213
312
Part Number
Page
1-1711691-9............................................228
1-1859400-4............................................163
1-1859401-4............................................163
1-1859402-4............................................163
1-1859403-4............................................163
1-1859404-1............................................163
1-1859408-4............................................163
1-1859409-4............................................163
1-1859410-4............................................163
1-1859411-4............................................163
1-1859412-4............................................163
1-1859413-4............................................163
1-1933286-1..................................268, 296
1-1933286-2..................................268, 296
1-2160266-3.............................................. 13
1-2160266-5.............................................. 13
1-2160650-5.............................................. 14
1-2160651-5.............................................. 14
1-406330-3...............................................251
1-5502776-1............................................179
1-5503948-0............................................185
1-6457567-6............................................179
1116571-1................................................290
1116697-1................................................286
1116697-3................................................286
1116698-1................................................286
1116698-3................................................286
1206114-8................................................167
1206121-2................................................168
1206134-1................................................168
1206144-1................................................168
1206145-1................................................168
1206146-1................................................168
1206343-4................................................167
1278118-4................................................190
1278118-5................................................190
1278531-1................................................194
1278567-1................................................172
1278567-2................................................172
1278625-1................................................194
1278637-1................................................194
1278755-4................................................170
1278949-2................................................192
1278949-3................................................192
1374463-1................................................171
1374463-2................................................171
1374463-5................................................171
1374463-6................................................171
1374484-1................................................197
1374526-1................................................170
1374598-1................................................171
1375013-2................................................232
1375015-2................................................232
1375016-2................................................232
1375055-X................................................229
www.te.com/enterprise-asia 12/13 318108AE
Part Number
Page
1375149-2................................................297
1375188-1................................................229
1375189-1................................................247
1375253-2........................................ 20, 298
1375254-2........................................ 20, 298
1375254-2................................................298
1375308-1................................................288
1375309-1................................................288
1375310-1................................................288
1375352-1................................................309
1375353-1................................................309
1379156-1................................................140
1394060-1................................................119
1394060-2......................................119, 269
1418800-1................................................168
1427016-2................................................280
1427319-1................................................227
1427490-1.................................................. 42
1427490-2.................................................. 42
1427491-1.................................................. 42
1427491-2.................................................. 42
1427493-1.................................................. 43
1427494-1.................................................. 43
1427495-1.................................................. 44
1427509-1.................................................. 43
1427543-1.................................................. 42
1427543-2.................................................. 42
1427544-1.................................................. 45
1427545-1.................................................. 18
1427560-1.................................................. 42
1427560-2.................................................. 42
1427561-1.................................................. 42
1427561-2.................................................. 42
1427573-1.................................................. 43
1427574-1.................................................. 43
1427577-1.................................................. 44
1427578-1.................................................. 44
1427592-1.................................................. 45
1427632-2.................................................. 44
1435346-1................................................123
1435346-4................................................123
1435346-5................................................123
1435516-1................................................171
1435516-3................................................171
1435516-5................................................171
1435516-6................................................171
1435657-1................................................115
1435657-2................................................115
1435657-3................................................115
1435688-1................................................115
1435688-2................................................115
1435689-1................................................115
1435689-2................................................115
1435779-1................................................124
1435818-1................................................123
Index
Part Number Index
Part Number
Page
1435820-1................................................123
1435827-1................................................123
1435927-1................................................123
1435933-1................................................123
1435937-1................................................123
1435939-1................................................123
1435950-1................................................123
1435952-1................................................123
1435954-1................................................119
1435965-1.................................................. 29
1435971-1.................................................. 29
1457628-1................................................196
1457630-1................................................195
1457630-2................................................195
1479002-1................................................309
1479003-1................................................309
1479153-2................................................250
1479154-2................................................250
1479155-2................................................250
1479156-2................................................250
1479437-1................................................298
1479440-1................................................298
1479441-1................................................298
1479506-1................................................172
1479698-1............................ 169, 282, 295
1479701-1................................................295
1479890-1................................................123
1499101-1................................................204
1499602-2................................................250
1499603-2................................................250
1499651-1................................................123
1499659-1................................................124
1499659-2................................................124
1499659-3................................................124
1499660-1................................................123
1553212-1................................................190
1553668-1........................................ 18, 165
1553761-1.................................................. 93
1553785-1................................................200
1557548-1................................................124
1583236-1................................................288
1583608-1................................................288
1588175-1................................................194
1588176-1................................................194
1588756-1................................................195
1591020-2................................................302
1591020-7................................................302
1591022-2................................................302
1591022-7................................................302
1591024-2................................................301
1591024-7................................................301
1591026-2................................................301
1591026-7................................................301
1591029-2................................................301
1591029-7................................................301
Part Number
Page
1591030-2................................................301
1591030-7................................................301
1591031-2................................................301
1591031-7................................................301
1591032-2................................................301
1591032-7................................................301
1591034-0................................................301
1591185-0................................................300
1591188-2................................................300
1591188-7................................................300
1591369-1................................................104
1591369-2................................................104
1591369-3................................................104
1591369-4................................................104
1591369-5................................................104
1591369-6................................................104
1591369-7................................................104
1591721-1................................................142
1591721-3................................................142
1591721-5................................................142
1644016-X................................................147
1644042-1................................................118
1644042-2................................................233
1644042-3................................................233
1671000-8................................................167
1671054-1................................................168
1671054-2................................................168
1671146-1................................................172
1671149-1................................................115
1671149-3................................................115
1671149-5......................................115, 166
1671175-1.................................................. 33
1671189-1.................................................. 47
1671189-2.................................................. 47
1671189-4.................................................. 47
1671195-1................................................169
1671195-2................................................169
1671196-1................................................169
1671196-2................................................169
1671196-3................................................169
1671196-4................................................169
1671200-1........................................ 19, 169
1671201-1................................................169
1671201-2................................................169
1671201-3................................................169
1671201-4................................................169
1671202-1................................................169
1671202-2................................................169
1671202-3................................................169
1671202-4................................................169
1671205-4.....................................................8
1671205-6.....................................................8
1671206-4.....................................................8
1671206-6.....................................................8
1671207-4.....................................................8
Part Number
Page
1671207-6.....................................................8
1671209-3................................................115
1671209-4................................................115
1671226-5.....................................................4
1671227-5.....................................................4
1671228-3.....................................................4
1671229-5................................................115
1671281-1................................................187
1671281-2................................................187
1671281-3................................................187
1671415-1................................................310
1671415-2................................................310
1671415-3................................................310
1671415-4................................................310
1671633-1.................................................. 98
1671907-1.................................................. 98
1673956-1................................................288
1711000-X................................................147
1711001-X................................................147
1711003-1................................................204
1711005-1................................................211
1711007-1................................................226
1711008-1................................................226
1711100-1................................................146
1711100-3................................................146
1711100-5................................................146
1711125-1................................................145
1711125-3................................................145
1711125-5................................................145
1711135-1................................................146
1711135-3................................................146
1711135-5................................................146
1711147-1................................................118
1711147-2................................................233
1711148-1................................................121
1711148-4................................................121
1711160-2................................................228
1711163-1................................................211
1711195-1................................................211
1711295-2................................................228
1711301-1................................................284
1711302-1................................................284
1711314-1.................................................. 19
1711314-2.................................................. 19
1711314-3.................................................. 19
1711336-1................................................142
1711336-3................................................142
1711336-5................................................142
1711339-1................................................147
1711342-2................................................228
1711343-2................................................228
1711344-1................................................124
1711348-1................................................284
1711351-5................................................122
1711351-6................................................122
318108AE 12/13 www.te.com/enterprise-asia
313
Index
Part Number Index
Part Number
Page
1711351-7................................................122
1711351-8................................................122
1711409-1................................................141
1711409-3................................................141
1711409-5................................................141
1711437-1................................................205
1711441-1................................................205
1711450-1................................................146
1711450-3................................................146
1711450-5................................................146
1711491-1................................................284
1711500-1................................................148
1711592-1................................................213
1711609-1................................................141
1711609-3................................................141
1711609-5................................................141
1711655-1................................................137
1711655-3................................................137
1711685-1................................................279
1711685-2................................................279
1711685-4................................................121
1711686-1................................................135
1711686-3................................................135
1711716-1................................................213
1711742-1................................................121
1711749-1................................................121
1711775-1................................................284
1711784-1................................................148
1711784-2................................................148
1711796-1................................................142
1711796-3................................................142
1711796-5................................................142
1711801-1................................................143
1711801-3................................................143
1711801-5................................................143
1711804-1................................................143
1711804-3................................................143
1711804-5................................................143
1711807-1................................................143
1711807-3................................................143
1711807-5................................................143
1711855-1................................................138
1711856-1................................................137
1711858-1................................................138
1711858-2................................................138
1711858-3................................................138
1711858-4................................................138
1711859-1................................................138
1711859-2................................................138
1711860-1................................................140
1711860-2................................................140
1711861-1................................................139
1711862-1................................................139
1711864-1................................................139
1711865-1................................................139
314
Part Number
Page
1711866-1................................................139
1711869-1................................................138
1711870-1................................................137
1711875-1................................................137
1711876-1................................................138
1711910-1................................................204
1711913-1................................................204
1711944-1.................................................. 29
1711944-2................................................117
1711970-1.................................................. 28
1711987-1........................................ 19, 169
1725150-1................................................288
1725150-3................................................288
1754074-1................................................195
1754137-1................................................194
1754371-2......................................180, 184
1754462-1................................................191
1754603-1................................................192
1754708-1................................................194
1754765-1................................................200
1754766-1................................................200
1754767-1................................................200
1754768-1................................................200
1754845-1................................................190
1754845-2................................................190
1777005-1................................................123
1777014-1................................................123
1777019-1................................................123
1777029-1.................................................. 29
1777029-2................................................117
1777041-1................................................117
1777042-1................................................117
1777053-1................................................117
1777098-1.................................................. 29
182398-000..............................................187
1828352-1................................................201
1828352-2................................................201
1828353-1................................................201
1828833-1................................................200
1828836-1................................................200
1828837-1................................................200
1828953-3................................................181
183553-1...................................................147
183578-1...................................................147
183635-1...................................................145
183635-3...................................................145
183635-5...................................................145
183636-1...................................................144
183636-3...................................................144
183636-5...................................................144
183641-1...................................................145
183641-3...................................................145
183641-5...................................................145
1859049-1................................................283
1859050-1................................................283
www.te.com/enterprise-asia 12/13 318108AE
Part Number
Page
1859053-1................................................283
1859096-1................................................284
1859167-1................................................283
1859168-1................................................283
1859181-1................................................280
1859182-1................................................280
1859606-1................................................289
1871696-1......................................189, 193
1918266-1................................................184
1918267-1................................................184
1918267-3................................................184
1918374-1................................................184
1918375-1................................................184
1918375-3................................................184
1918384-1................................................184
1918385-1................................................184
1918385-3................................................184
1918447-1................................................128
1918626-1................................................180
1918627-1................................................180
1918627-2................................................180
1918627-3................................................180
1918652-1................................................197
1918802-1........................................ 23, 199
1918803-1........................................ 23, 199
1918804-1................................................199
1918805-1........................................ 23, 199
1918806-1........................................ 23, 199
1918807-1................................................199
1918808-1................................................199
1918809-1.................................................. 23
1918809-1................................................199
1918810-1................................................199
1918811-1................................................199
1933098-1................................................123
1933140-1................................................310
1933140-2................................................310
1933140-3................................................310
1933140-4................................................310
1933196-1................................................120
1933197-1................................................120
1933286-3......................................268, 296
1933286-4......................................268, 296
1933286-6......................................268, 296
1933287-1................................................287
1933287-2................................................287
1933287-3................................................287
1933288-1................................................287
1933288-2................................................287
1933288-3................................................287
1933307-1................................................278
1933308-1................................................278
1933309-1................................................278
1933310-1................................................278
1933319-2................................................215
Index
Part Number Index
Part Number
Page
1933320-2................................................215
1933321-2................................................215
1933322-2................................................215
1933327-1................................................119
1933328-1................................................119
1933329-1................................................119
1933330-1................................................119
1933331-1................................................119
1933332-1................................................119
1933333-1................................................119
1933334-1................................................119
1933352-1.................................................. 34
1933352-2.................................................. 34
1933352-3.................................................. 34
1933352-4.................................................. 34
1933412-1................................................278
1933420-2................................................115
1933420-3................................................115
1933425-1................................................124
1933443-1........................................ 18, 165
1933476-X................................................215
1933677-1................................................286
1933691-1................................................294
1933692-1................................................294
1933693-1................................................294
1933776-1................................................294
1933796-2................................................232
1933797-2................................................232
1933798-2................................................232
1933799-2................................................232
1933899-1................................................123
1985374-1................................................182
1985766-1................................................194
1985771-1................................................193
1985805-1................................................182
1987031-2................................................304
1987032-2................................................304
1987033-2................................................304
1987152-2................................................303
1987154-2................................................304
1987155-2................................................304
1987256-2................................................305
1987257-2................................................305
2
2-1206114-4............................................167
2-1206343-2............................................167
2-1591360-3............................................113
2-1671000-2............................................167
2-1671000-4............................................167
2-1671000-8............................................167
2-1711655-1............................................137
2-1711856-1............................................137
2-1711870-1............................................137
2-1711875-1............................................137
Part Number
Page
2-336539-1...............................................231
2-5502776-6............................................179
2055567-1.................................................. 20
2055567-2.................................................. 20
2064181-1......................................180, 181
2064431-1................................................194
2064453-2................................................194
2064499-1........................................ 23, 199
2064500-1........................................ 23, 199
2064540-1................................................193
2064603-1................................................194
2064651-1................................................198
2064651-2................................................198
2064651-3................................................198
2111008-1................................................285
2111009-1................................................285
2111010-1................................................285
2111011-1................................................285
2111012-1................................................285
2111013-1................................................285
2111014-1................................................285
2111015-1................................................285
2111093-1......................................282, 295
2111117-1......................................282, 295
2111121-1................................................248
2111122-1................................................248
2111123-1................................................230
2111124-1................................................230
2111201-1................................................285
2111203-1................................................285
2111440-2................................................114
2111441-2................................................114
2111441-4................................................114
2111442-2................................................114
2111443-1................................................114
2111444-4................................................114
2111445-4................................................114
2111446-4................................................114
2111447-4................................................114
2111448-4................................................114
2111481-1.................................................. 93
2111500-2......................................268, 296
2111664-1.................................................. 23
2111676-X................................................215
2119000-1................................................290
2119700-1................................................290
2123273-1................................................200
2153004-1................................................284
2153014-1......................................136, 295
2153040-1................................................117
2153041-1.................................................. 26
2153046-1.................................................. 26
2153049-1................................................117
2153074-1................................................139
2153075-1................................................139
Part Number
Page
2153091-1................................................117
2153112-1................................................134
2153112-3................................................134
2153113-1................................................134
2153113-3................................................134
2153115-1.................................................. 26
2153117-1................................................148
2153161-1................................................211
2153173-3................................................136
2153175-2................................................114
2153188-1................................................100
2153190-1................................................100
2160266-3.................................................. 13
2160266-5.................................................. 13
2160270-2.................................................. 95
2160270-3.................................................. 95
2160317-1.................................................. 94
2160317-2.................................................. 94
2160318-1.................................................. 94
2160318-2.................................................. 94
2160319-1.................................................. 94
2160319-2.................................................. 94
2160320-1.................................................. 94
2160320-2.................................................. 94
2160321-1.................................................. 94
2160321-2.................................................. 94
2160322-1.................................................. 94
2160322-2.................................................. 94
2160323-1.................................................. 94
2160323-2.................................................. 94
2160324-1.................................................. 94
2160324-2.................................................. 94
2160325-1.................................................. 94
2160325-2.................................................. 94
2160385-1.................................................. 94
2160385-2.................................................. 94
2160386-1.................................................. 94
2160386-2.................................................. 94
2160387-1.................................................. 94
2160387-2.................................................. 94
2160388-1.................................................. 94
2160388-2.................................................. 94
2160389-1.................................................. 94
2160389-2.................................................. 94
2160390-1.................................................. 94
2160390-2.................................................. 94
2160391-1.................................................. 94
2160391-2.................................................. 94
2160392-1.................................................. 94
2160392-2.................................................. 94
2160503-1.................................................. 94
2160503-2.................................................. 94
2160506-1................................................102
2160506-2................................................102
2160537-1................................................102
318108AE 12/13 www.te.com/enterprise-asia
315
Index
Part Number Index
Part Number
Page
2160538-1................................................102
2160547-3................................................202
2160548-3................................................202
2160549-3................................................202
2160550-3................................................202
2160551-3................................................202
2160552-3................................................202
2160639-5.................................................. 13
2160640-5.................................................. 13
2160649-5.................................................. 14
2160650-5.................................................. 14
2160651-5.................................................. 14
2193016-1.................................................. 93
2193050-1.................................................. 93
2193051-1.................................................. 93
2193052-1.................................................. 93
219484-2...................................................245
228433-5...................................................197
228433-7...................................................197
228433-8...................................................197
228433-9...................................................197
284584-1...................................................144
284584-3...................................................144
284584-5...................................................144
3
300001739943........................................281
300001739995........................................281
300001741753........................................281
300001743975........................................214
300001743978........................................214
3-1591360-1............................................113
336455-1...................................................148
336455-2...................................................148
336455-3...................................................148
336526-1...................................................279
336526-4...................................................279
336539-1...................................................231
336548-1...................................................144
336548-3...................................................144
336548-5...................................................144
336556-1...................................................141
336556-3...................................................141
336556-5...................................................141
336671-2...................................................249
4
4-1206114-4............................................167
4-1206343-2............................................167
4-1206343-4............................................167
4-1671000-2............................................167
4-1671000-4............................................167
4-1671000-8............................................167
4-1671002-4............................................167
406330-1...................................................251
316
Part Number
Page
406331-1...................................................251
406332-1...................................................251
406390-1...................................................251
406641-1...................................................258
406981-1...................................................251
492025-1...................................................194
492026-1...................................................194
492109-2...................................................194
492543-1...................................................190
492622-1...................................................194
492623-1...................................................194
492697-1...................................................190
492697-2...................................................190
492703-1...................................................193
492782-1...................................................194
492783-1...................................................194
5
501014-1...................................................194
501197-1...................................................196
501198-1...................................................194
501258-8...................................................191
501457-1...................................................186
501457-3...................................................186
501473-3...................................................197
501523-1...................................................196
501818-1...................................................195
501857-2...................................................195
501858-1...................................................196
502129-1...................................................196
502134-2...................................................196
502222-1...................................................196
502259-1...................................................195
502282-2...................................................197
502418-1...................................................197
502631-1...................................................195
502656-1...................................................195
502748-2...................................................197
503304-1...................................................195
503330-1...................................................190
503337-1...................................................195
503577-1...................................................188
503605-1...................................................189
503676-1...................................................186
503677-1...................................................186
503681-1...................................................188
503705-1...................................................193
503746-1...................................................192
503746-7...................................................192
503787-1...................................................195
503910-1...................................................194
503911-1...................................................194
503957-1...................................................190
503957-3...................................................190
504021-1...................................................179
www.te.com/enterprise-asia 12/13 318108AE
Part Number
Page
504035-1...................................................196
504064-1...................................................195
504290-1...................................................195
5492123-1................................................185
5492642-2................................................181
5492643-1................................................181
5502580-2................................................186
5503613-2................................................186
5503628-1................................................186
5503692-1................................................183
5503693-1................................................183
5503948-1................................................185
5504000-1................................................183
5504034-1................................................183
5504600-1................................................183
5504640-1................................................179
5504646-1................................................185
5504932-1................................................185
5504932-5................................................185
555050-1...................................................267
555052-1...................................................267
555614-1...................................................147
555644-1...................................................147
555644-3...................................................147
555644-5...................................................147
555644-9...................................................147
557403-1...................................................269
557411-1...................................................269
557415-1...................................................269
558251-1...................................................285
558251-3...................................................285
558257-1...................................................269
558258-1...................................................269
558259-1...................................................269
558401-1...................................................256
558402-1...................................................256
558635-1...................................................258
558637-1...................................................258
558639-1...................................................258
558838-1...................................................257
558839-1...................................................256
558840-1...................................................256
558841-1...................................................256
558842-1...................................................256
558843-1...................................................256
559066-1...................................................189
559087-1...................................................189
559501-2...................................................170
559515-2...................................................172
559523-1...................................................172
559542-2...................................................128
559552-2...................................................128
559557-1...................................................172
559558-2...................................................171
559558-4...................................................171
Index
Part Number Index
Part Number
Page
559558-6...................................................171
559558-7...................................................171
559560-2...................................................170
559561-2...................................................170
559596-2...................................................171
559596-3...................................................128
559596-3...................................................171
559596-4...................................................171
559596-7...................................................171
559614-2...................................................128
569389-1...................................................258
569431-1...................................................258
569433-1...................................................257
569434-1...................................................257
569439-1...................................................257
569440-1...................................................257
569445-1...................................................257
569446-1...................................................257
569597-1...................................................258
569599-1...................................................258
569851-1...................................................258
569852-1...................................................258
569854-1...................................................257
569855-1...................................................257
569857-1...................................................257
569858-1...................................................257
57893-1.....................................................211
58424-1.....................................................194
58433-4.....................................................194
5909 1 076-00.........................................274
5909 1 078-10.........................................274
5909 1 082-00.........................................274
5909 1 083-00.........................................274
5909 1 084-00.........................................274
6
6089 1 102- .............................................237
6450 1 102-10.........................................241
6036 2 005-02.........................................223
6089 1 102-02.........................................270
6089 1 810-00...............................270, 271
6092 1 820-00.........................................271
6278079-2................................................181
6278082-1................................................181
6278082-2................................................181
6348522-1............................ 181, 183, 185
6348522-2................................................183
6348522-3................................................183
6348522-4................................................183
6406 1 001-xx.........................................276
6406 1 015-xx.........................................276
6406 2 004-20.........................................276
6406 2 013-00.........................................276
6406 3 003-20.........................................276
6417 2 055-01.........................................290
Part Number
Page
6424 3 005-01.........................................272
6424 3 005-02.........................................272
6424 3 005-07.........................................272
6424 3 007-10.........................................272
6424 3 009-30.........................................272
6424 3 010-34.........................................272
6428 2 418-00.........................................277
6428 2 419-00.........................................277
6428 2 420-00.........................................277
6428 2 421-00.........................................277
6428 2 422-00.........................................277
6428 2 423-00.........................................277
6428 2 424-00.........................................277
6428 2 425-00.........................................277
6429 1 076-00.........................................275
6429 1 078-00.........................................275
6436 1 001-xx.........................................276
6436 1 013-xx.........................................276
6436 2 004-20.........................................276
6436 3 003-20.........................................276
6437 1 001-xx.........................................276
6437 1 020-xx.........................................276
6437 2 004-20.........................................276
6437 2 010-00.........................................276
6437 3 003-20.........................................276
6450 1 101-10.........................................241
6450 1 101-11.........................................260
6450 1 103-10.........................................224
6450 1 103-10.........................................242
6450 1 104-10.........................................224
6450 1 104-10.........................................242
6450 1 105-11.........................................243
6450 1 105-21.........................................222
6450 1 107-01.........................................222
6450 1 176-01.........................................243
6450 1 177-01.........................................243
6450 1 178-01.........................................243
6450 1 180-00.........................................260
6450 1 210-00.........................................243
6450 2 155-01.........................................241
6450 2 156-20...............................224, 242
6450 2 157-10...............................224, 242
6450 2 157-20...............................224, 242
6450 2 158-20...............................224, 242
6450 2 176-00.........................................243
6450 2 177-00.........................................243
6450 2 178-00.........................................243
6451 2 050-11.........................................263
6451 2 050-21.........................................263
6451 2 050-31.........................................263
6451 2 050-51.........................................263
6451 2 057-11.........................................263
6451 2 057-21.........................................263
6451 2 057-31.........................................263
6451 2 057-51.........................................263
Part Number
Page
6451 2 099-30.........................................265
6451 2 100-30.........................................265
6451 2 101-10.........................................264
6451 2 101-20.........................................264
6451 2 101-30.........................................264
6451 2 102-10.........................................264
6451 2 102-20.........................................264
6451 2 102-30.........................................264
6451 2 104-10.........................................264
6451 2 104-20.........................................264
6451 2 104-30.........................................264
6451 2 400C-10......................................225
6451 2 400C-20......................................225
6451 2 400C-30......................................225
6451 2 400C-40......................................225
6451 2 401C-10......................................225
6451 2 401C-20......................................225
6451 2 401C-30......................................225
6451 2 401C-40......................................225
6451 2 403C-10......................................225
6451 2 403C-20......................................225
6451 2 403C-30......................................225
6451 2 403C-40......................................225
6451 2 404C-10......................................225
6451 2 404C-20......................................225
6451 2 404C-30......................................225
6451 2 404C-40......................................225
6451 2 700C-10......................................244
6451 2 700C-20......................................244
6451 2 700C-30......................................244
6451 2 700C-40......................................244
6451 2 701C-10......................................244
6451 2 701C-20......................................244
6451 2 701C-30......................................244
6451 2 701C-40......................................244
6451 2 702-10.........................................244
6451 2 702-20.........................................244
6451 2 702-30.........................................244
6451 2 702-40.........................................244
6451 2 703C-10......................................244
6451 2 703C-20......................................244
6451 2 703C-30......................................244
6451 2 703C-40......................................244
6451 2 704C-10......................................244
6451 2 704C-20......................................244
6451 2 704C-30......................................244
6451 2 704C-40......................................244
6457567-4................................................179
6457567-8................................................179
6462 2 408-01.........................................241
6467 1 140-00.........................................291
6467 2 142-00.........................................291
6467 2 149-00.........................................291
6468 5 061-00.........................................261
6468 5 061-08.........................................261
318108AE 12/13 www.te.com/enterprise-asia
317
Index
Part Number Index
Part Number
Page
6468 5 070-00.........................................223
6468 5 080-00.........................................262
6468 5 081-00.........................................262
6468 5 300-10.........................................241
6468 5 600-10.........................................241
6468 5 700-10.........................................223
6527 1 607-24.........................................251
6529 1 022-01.........................................273
6529 1 042-01.........................................273
6529 1 202-XX........................................253
6529 1 203-XX........................................253
6529 1 205-XX........................................253
6530 1 017-00.........................................275
6534 1 001-00.........................................271
6537 1 610-00.........................................290
6538 3 111-03.........................................284
6538 3 111-04.........................................284
657054-000..............................................187
6588291-2................................................181
6693276-1................................................181
6645-2-8X0-YY.......................................218
6645-2-8X5-YY.......................................218
6753 2 009-00.........................................271
6754482-1................................................180
6754483-1................................................180
6754483-2................................................180
6754483-4................................................180
6830 1 490-00.........................................291
6830 1 800-01.........................................230
6830 1 800-04.........................................230
6830 1 810-01.........................................228
6830 1 810-04.........................................228
6830 1 811-01.........................................213
6830 1 811-04.........................................213
6830 1 885-01.........................................214
6830 1 885-04.........................................214
7
7-1859666-1............................................100
7014 1 601-00.........................................270
7014 2 007-00.........................................271
7014 2 040-00.........................................273
7014 2 152-00.........................................270
7014 3 046-11.........................................276
7014 3 046-12.........................................276
7014 3 046-13.........................................276
7019 1 014-00.........................................274
7022 1 015-24.........................................249
7022 2 155-24.........................................281
7022 2 155-32.........................................281
7022 4 001-25.........................................269
7022 4 001-50.........................................269
7080 2 064-10.........................................287
7080 2 065-10.........................................287
318
Part Number
Page
8
84841-1.....................................................280
9
969704-1.........................................148, 308
F
FGS-ASRI-10F...................................53, 66
FGS-ASRI-15F...................................53, 66
FGS-ASRI-5F......................................53, 66
FGS-CD4E-A............................................. 51
FGS-CD4E-B............................................. 64
FGS-CD9E-A............................................. 51
FGS-CD9E-B............................................. 64
FGS-CDSA-AB.......................................... 51
FGS-CDSA-AB.......................................... 64
FGS-CH4E-A............................................. 51
FGS-CH4E-B............................................. 64
FGS-CH9E-A............................................. 51
FGS-CH9E-B............................................. 64
FGS-CHRT-A............................................. 51
FGS-CHRT-B............................................. 64
FGS-CHXP-A............................................. 51
FGS-CHXP-B............................................. 64
FGS-CU4E-B............................................. 64
FGS-CU9E-B............................................. 64
FGS-DHCP........................... 54, 60, 67, 74
FGS-DHHC.................................. 54, 67, 74
FGS-FD4E-H.............................................. 81
FGS-FDSA-HF........................................... 81
FGS-FH4E-H.............................................. 81
FGS-FHRT-H.............................................. 81
FGS-FHRT-H/F......................................... 81
FGS-FHXP-F/H........................................ 81
FGS-FHXP-H............................................. 81
FGS-FSFC-H.............................................. 81
FGS-HASB-1/2-36.................................. 90
FGS-HASB-1/2-48.................................. 90
FGS-HASB-5/8-36.................................. 90
FGS-HASB-5/8-48.................................. 90
FGS-HCBL-12........................................... 87
FGS-HCBL-15........................................... 87
FGS-HDGR................................................. 90
FGS-HDLB-3.............................................. 87
FGS-HDSI-AB.....................................53, 66
FGS-HDSI-F/C.......................................... 73
FGS-HDSI-F/D......................................... 73
FGS-HETP-F-XX...................................... 88
FGS-HETP-H-5/8.................................... 89
FGS-HETR-5/8-A.................................... 87
FGS-HETR-F-XX...................................... 88
FGS-HETR-XX........................................... 87
FGS-HFCK-1/2......................................... 90
FGS-HFCK-5/8......................................... 90
FGS-HFRR-10........................................... 90
www.te.com/enterprise-asia 12/13 318108AE
Part Number
Page
FGS-HHEC-10........................................... 90
FGS-HHGK................................................. 90
FGS-HIFC-A............................................... 90
FGS-HIFC-B............................................... 90
FGS-HIFC-F............................................... 90
FGS-HKFM-XX.......................................... 90
FGS-HLBK.................................................. 87
FGS-HLDR-A............................................. 90
FGS-HLDR-XX.......................................... 90
FGS-HMEC-A............................................ 51
FGS-HMEC-B............................................ 64
FGS-HMEC-F............................................. 71
FGS-HMEC-G............................................ 59
FGS-HMEC-H............................................ 79
FGS-HNLR-AB.......................................... 87
FGS-HNLR-F............................................. 88
FGS-HNTP-F-XX...................................... 88
FGS-HNTP-H-5/8.................................... 89
FGS-HNTR-5/8-A.................................... 87
FGS-HNTR-F-XX...................................... 88
FGS-HNTR-XX.......................................... 87
FGS-HNTS-F-XX...................................... 88
FGS-HNTS-F-XX-LP............................... 88
FGS-HNTS-XX........................................... 87
FGS-HNTS-XX-LP.................................... 87
FGS-HOMX-16MM................................... 87
FGS-HRJA-A/B/F................................... 90
FGS-HTHR-1/2-12.................................. 90
FGS-HTHR-1/2-30.................................. 90
FGS-HTHR-1/2-72.................................. 90
FGS-HTHR-5/8-12.................................. 90
FGS-HTHR-5/8-30.................................. 90
FGS-HTHR-5/8-72.................................. 90
FGS-HTHR-XX-NN.................................. 90
FGS-HTUB-F-XX...................................... 88
FGS-HTUB-XX.......................................... 87
FGS-HUFB-A............................................. 87
FGS-ISLAND-F......................................... 73
FGS-ISLAND-F-513................................ 73
FGS-ISLAND-H/F.................................... 80
FGS-ISLAND3-F....................................... 73
FGS-JUNC-G............................................. 60
FGS-KQKB................................................. 90
FGS-KT03-A.......................................53, 66
FGS-KT03-A1.....................................53, 66
FGS-KT03-A1-10F............................53, 66
FGS-KT03-A1-15F............................53, 66
FGS-KT03-A10F................................53, 66
FGS-KT03-A15F................................53, 66
FGS-KT03-A4-10F............................53, 66
FGS-KT03-A4-15F............................53, 66
FGS-KT03-A4-5F..............................53, 66
FGS-KT03-B.............................................. 73
FGS-KT03-B-10F..................................... 73
FGS-KT03-B-15F..................................... 73
Index
Part Number Index
Part Number
Page
FGS-KT03-C.............................................. 85
FGS-KT03-C-10F..................................... 85
FGS-KT03-C-15F..................................... 85
FGS-KT03-G-5F....................................... 59
FGS-KT07-A4-10F............................53, 66
FGS-KT07-A4-15F............................53, 66
FGS-KT07-A4-5F..............................53, 66
FGS-KT09................................................... 90
FGS-MCDS-AB..................................53, 66
FGS-MCDS-EX-AB...........................53, 66
FGS-MD4E-A............................................. 51
FGS-MD4E-B............................................. 64
FGS-MD4E-F............................................. 71
FGS-MD4E-G............................................. 59
FGS-MD4E-H............................................. 79
FGS-MD9E-A............................................. 51
FGS-MD9E-B............................................. 64
FGS-MD9E-F............................................. 71
FGS-MD9E-G............................................. 59
FGS-MDRT-F............................................. 73
FGS-MDSA-AB..................................51, 64
FGS-MDSA-F2B....................................... 71
FGS-MDSA-FB...................................64, 71
FGS-MDSA-FB-L...................................... 71
FGS-MDSA-FB-R..................................... 71
FGS-MDSA-GA......................................... 59
FGS-MDSA-GB......................................... 59
FGS-MDSA-HF.......................................... 79
FGS-MDSP-2B.......................................... 66
FGS-MDSP-2B-IMP................................. 66
FGS-MDSP-A............................................. 53
FGS-MDSP-A/I......................................... 53
FGS-MDSP-B............................................. 66
FGS-MDSP-B/I......................................... 66
FGS-MDSP-EX-A..................................... 53
FGS-MDSP-EX-B...................................... 66
FGS-MDSP-F............................................. 73
FGS-MDSP-F-VS...................................... 71
FGS-MDSP-F/I......................................... 73
FGS-MDSP-G............................................. 59
FGS-MEX1-C-10F.................................... 85
FGS-MEX1-C-15F.................................... 85
FGS-MEX1-C-5F...................................... 85
FGS-MEXC-E-A........................................ 84
FGS-MEXC-E-A/B/F.............................. 84
FGS-MEXC-E-B........................................ 84
FGS-MEXC-E-F......................................... 84
FGS-MEXP-A/B/F.................................. 85
FGS-MEXP-E-A/B/F.............................. 84
FGS-MEXP-LP-A/B/F........................... 85
FGS-MEXP-LP-G...................................... 59
FGS-MFAW-A............................................ 54
FGS-MFAW-B............................................ 67
FGS-MFAW-F............................................ 75
FGS-MFAW-H............................................ 81
Part Number
Page
FGS-MFIN-10............................................ 90
FGS-MFTY-XF........................................... 90
FGS-MH4E-A............................................. 51
FGS-MH4E-B............................................. 64
FGS-MH4E-F............................................. 71
FGS-MH4E-G............................................. 59
FGS-MH4E-H............................................. 79
FGS-MH4E-H-VS...................................... 89
FGS-MH9E-A............................................. 51
FGS-MH9E-B............................................. 64
FGS-MH9E-F............................................. 71
FGS-MH9E-F-VS...................................... 71
FGS-MH9E-G............................................. 59
FGS-MHIS-A............................... 51, 64, 71
FGS-MHIS-A/H......................................... 79
FGS-MHIS-B............................... 51, 64, 71
FGS-MHIS-B/H......................................... 79
FGS-MHIS-F................................ 51, 64, 71
FGS-MHIS-F/H......................................... 79
FGS-MHIS-JIG-A/B/F............ 51, 64, 71
FGS-MHRT-A............................................. 51
FGS-MHRT-B............................................. 64
FGS-MHRT-F............................................. 71
FGS-MHRT-F-VS...................................... 71
FGS-MHRT-F/B........................................ 71
FGS-MHRT-F/B-VS................................. 71
FGS-MHRT-G............................................. 59
FGS-MHRT-H............................................. 79
FGS-MHRT-H/F........................................ 79
FGS-MHRT-H/F-VS................................. 89
FGS-MHXP-A............................................ 51
FGS-MHXP-B............................................ 64
FGS-MHXP-B/F....................................... 71
FGS-MHXP-B/F-VS................................ 71
FGS-MHXP-F............................................. 71
FGS-MHXP-F-VS...................................... 71
FGS-MHXP-F/H....................................... 79
FGS-MHXP-F/H-VS................................ 89
FGS-MHXP-G............................................ 59
FGS-MHXP-H............................................ 79
FGS-MHXP-H-VS..................................... 89
FGS-MIDY-XF............................................ 90
FGS-MISY-XF............................................ 90
FGS-MJWR-A....................................53, 66
FGS-MKIT................................................... 90
FGS-MKIT-ABF......................................... 90
FGS-MLDY-XF........................................... 90
FGS-MSHS-A............................................. 54
FGS-MSHS-B............................................. 67
FGS-MSHS-F............................................. 74
FGS-MSHS-G............................................. 60
FGS-MSHS-H............................................. 81
FGS-MSHS-STOR-B................................ 67
FGS-MSHS-STOR-F................................ 74
FGS-MSNC-A............................................ 54
Part Number
Page
FGS-MSNC-B/G................................60, 67
FGS-MSNC-F............................................. 74
FGS-MSSC-A............................................. 54
FGS-MSSC-B/G.................................60, 67
FGS-MSSC-F............................................. 74
FGS-MSTOR-A/B/F............................... 90
FGS-MTRM-2B.......................................... 66
FGS-MTRM-2B-IMP................................. 66
FGS-MTRM-A.....................................53, 66
FGS-MTRM-B............................................ 73
FGS-MTRM-C............................................ 85
FGS-MTRM-F............................................ 73
FGS-MTRM-G............................................ 59
FGS-MTRM-H............................................ 80
FGS-MU4E-A............................................. 51
FGS-MU4E-B............................................. 64
FGS-MU4E-F............................................. 71
FGS-MU4E-G............................................. 59
FGS-MU4E-H............................................. 79
FGS-MU9E-A............................................. 51
FGS-MU9E-B............................................. 64
FGS-MVAR-A.....................................51, 54
FGS-MVAR-B.....................................64, 67
FGS-MVAR-F......................................71, 74
FGS-SD4E-A.............................................. 51
FGS-SD4E-B.............................................. 64
FGS-SD4E-F.............................................. 71
FGS-SD9E-A.............................................. 51
FGS-SD9E-B.............................................. 64
FGS-SD9E-F.............................................. 71
FGS-SDSA-AB...................................51, 64
FGS-SDSA-F2B........................................ 71
FGS-SDSA-FB....................................64, 71
FGS-SDSP-F.............................................. 73
FGS-SH4E-A.............................................. 51
FGS-SH4E-B.............................................. 64
FGS-SH4E-F.............................................. 71
FGS-SH9E-A.............................................. 51
FGS-SH9E-B.............................................. 64
FGS-SH9E-F.............................................. 71
FGS-SHRT-A.............................................. 51
FGS-SHRT-B.............................................. 64
FGS-SHRT-F.............................................. 71
FGS-SHRT-F/B......................................... 71
FGS-SHXP-A............................................. 51
FGS-SHXP-B............................................. 64
FGS-SHXP-B/F........................................ 71
FGS-SHXP-F.............................................. 71
FGS-SU4E-A.............................................. 51
FGS-SU4E-B.............................................. 64
FGS-SU4E-F.............................................. 71
FGS-SU9E-A.............................................. 51
FGS-VDSA-FB-L...................................... 71
FGS-VDSA-FB-R...................................... 71
FGSB-ASRI-10F................................53, 66
318108AE 12/13 www.te.com/enterprise-asia
319
Index
Part Number Index
Part Number
Page
FGSB-ASRI-15F................................53, 66
FGSB-ASRI-5F...................................53, 66
FGSB-DHHC............................... 54, 67, 74
FGSB-ISLAND-F...................................... 73
FGSB-ISLAND-F-513............................. 73
FGSB-ISLAND-H/F................................. 80
FGSB-ISLAND3-F.................................... 73
FGSB-JUNC-G.......................................... 60
FGSB-KT03-A....................................53, 66
FGSB-KT03-A1..................................53, 66
FGSB-KT03-A1-10F.........................53, 66
FGSB-KT03-A1-15F.........................53, 66
FGSB-KT03-A10F.............................53, 66
FGSB-KT03-A15F.............................53, 66
FGSB-KT03-A4-10F.........................53, 66
FGSB-KT03-A4-15F.........................53, 66
FGSB-KT03-A4-5F...........................53, 66
FGSB-KT03-B........................................... 73
FGSB-KT03-B-10F.................................. 73
FGSB-KT03-B-15F.................................. 73
FGSB-KT03-C........................................... 85
FGSB-KT03-C-10F.................................. 85
FGSB-KT03-C-15F.................................. 85
FGSB-KT03-G-5F.................................... 59
FGSB-KT07-A4-10F.........................53, 66
FGSB-KT07-A4-15F.........................53, 66
FGSB-KT07-A4-5F...........................53, 66
FGSB-MCDS-AB...............................53, 66
FGSB-MCDS-EX-AB........................53, 66
FGSB-MD4E-A.......................................... 51
FGSB-MD4E-B.......................................... 64
FGSB-MD4E-F.......................................... 71
FGSB-MD4E-G.......................................... 59
FGSB-MD4E-H.......................................... 79
FGSB-MD9E-A.......................................... 51
FGSB-MD9E-B.......................................... 64
FGSB-MD9E-F.......................................... 71
FGSB-MD9E-G.......................................... 59
FGSB-MDRT-F.......................................... 73
FGSB-MDSA-AB...............................51, 64
FGSB-MDSA-F2B.................................... 71
FGSB-MDSA-FB................................64, 71
FGSB-MDSA-GA...................................... 59
FGSB-MDSA-GB...................................... 59
FGSB-MDSA-HF....................................... 79
FGSB-MDSP-2B....................................... 66
FGSB-MDSP-2B-IMP.............................. 66
FGSB-MDSP-A.......................................... 53
FGSB-MDSP-A/I...................................... 53
FGSB-MDSP-B.......................................... 66
FGSB-MDSP-B/I...................................... 66
FGSB-MDSP-EX-A................................... 53
FGSB-MDSP-EX-B................................... 66
FGSB-MDSP-F.......................................... 73
FGSB-MDSP-F/I...................................... 73
320
Part Number
Page
FGSB-MDSP-G.......................................... 59
FGSB-MEX1-C-10F................................. 85
FGSB-MEX1-C-15F................................. 85
FGSB-MEX1-C-5F................................... 85
FGSB-MEXC-E-A..................................... 84
FGSB-MEXC-E-A/B/F........................... 84
FGSB-MEXC-E-B..................................... 84
FGSB-MEXC-E-F...................................... 84
FGSB-MEXP-A/B/F............................... 85
FGSB-MEXP-E-A/B/F........................... 84
FGSB-MEXP-LP-A/B/F........................ 85
FGSB-MEXP-LP-G................................... 59
FGSB-MFAW-A......................................... 54
FGSB-MFAW-B......................................... 67
FGSB-MFAW-F......................................... 75
FGSB-MFAW-H......................................... 81
FGSB-MFTY-XF........................................ 90
FGSB-MH4E-A.......................................... 51
FGSB-MH4E-B.......................................... 64
FGSB-MH4E-F.......................................... 71
FGSB-MH4E-G.......................................... 59
FGSB-MH4E-H.......................................... 79
FGSB-MH9E-A.......................................... 51
FGSB-MH9E-B.......................................... 64
FGSB-MH9E-F.......................................... 71
FGSB-MH9E-G.......................................... 59
FGSB-MHIS-A............................ 51, 64, 71
FGSB-MHIS-A/H...................................... 79
FGSB-MHIS-B............................ 51, 64, 71
FGSB-MHIS-B/H...................................... 79
FGSB-MHIS-F............................. 51, 64, 71
FGSB-MHIS-F/H...................................... 79
FGSB-MHRT-A.......................................... 51
FGSB-MHRT-B.......................................... 64
FGSB-MHRT-F.......................................... 71
FGSB-MHRT-F/B..................................... 71
FGSB-MHRT-G.......................................... 59
FGSB-MHRT-H.......................................... 79
FGSB-MHRT-H/F..................................... 79
FGSB-MHXP-A......................................... 51
FGSB-MHXP-B.......................................... 64
FGSB-MHXP-B/F.................................... 71
FGSB-MHXP-F.......................................... 71
FGSB-MHXP-F/H.................................... 79
FGSB-MHXP-G......................................... 59
FGSB-MHXP-H......................................... 79
FGSB-MIDY-XF......................................... 90
FGSB-MISY-XF.......................................... 90
FGSB-MJWR-A.................................66, 53
FGSB-MLDY-XF........................................ 90
FGSB-MSHS-A.......................................... 54
FGSB-MSHS-B.......................................... 67
FGSB-MSHS-F.......................................... 74
FGSB-MSHS-G.......................................... 60
FGSB-MSHS-H.......................................... 81
www.te.com/enterprise-asia 12/13 318108AE
Part Number
Page
FGSB-MSHS-STOR-B............................. 67
FGSB-MSHS-STOR-F............................. 74
FGSB-MSNC-A......................................... 54
FGSB-MSNC-B/G.............................60, 67
FGSB-MSNC-F.......................................... 74
FGSB-MSSC-A.......................................... 54
FGSB-MSSC-B/G..............................60, 67
FGSB-MSSC-F.......................................... 74
FGSB-MTRM-2B....................................... 66
FGSB-MTRM-2B-IMP.............................. 66
FGSB-MTRM-A..................................53, 66
FGSB-MTRM-B......................................... 73
FGSB-MTRM-C......................................... 85
FGSB-MTRM-F......................................... 73
FGSB-MTRM-G......................................... 59
FGSB-MU4E-A.......................................... 51
FGSB-MU4E-B.......................................... 64
FGSB-MU4E-F.......................................... 71
FGSB-MU4E-G.......................................... 59
FGSB-MU4E-H.......................................... 79
FGSB-MU9E-A.......................................... 51
FGSB-MU9E-B.......................................... 64
FGSB-MVAR-A..................................51, 54
FGSB-MVAR-B..................................64, 67
FGSB-MVAR-F...................................71, 74
FGSB-SD4E-A........................................... 51
FGSB-SD4E-B........................................... 64
FGSB-SD4E-F........................................... 71
FGSB-SD9E-A........................................... 51
FGSB-SD9E-B........................................... 64
FGSB-SD9E-F........................................... 71
FGSB-SDSA-AB................................51, 64
FGSB-SDSA-F2B..................................... 71
FGSB-SDSA-FB.................................64, 71
FGSB-SDSP-F........................................... 73
FGSB-SH4E-A........................................... 51
FGSB-SH4E-B........................................... 64
FGSB-SH4E-F........................................... 71
FGSB-SH9E-A........................................... 51
FGSB-SH9E-B........................................... 64
FGSB-SH9E-F........................................... 71
FGSB-SHRT-A........................................... 51
FGSB-SHRT-B........................................... 64
FGSB-SHRT-F........................................... 71
FGSB-SHRT-F/B...................................... 71
FGSB-SHXP-A.......................................... 51
FGSB-SHXP-B.......................................... 64
FGSB-SHXP-B/F..................................... 71
FGSB-SHXP-F........................................... 71
FGSB-SU4E-A........................................... 51
FGSB-SU4E-B........................................... 64
FGSB-SU4E-F........................................... 71
FGSB-SU9E-A........................................... 51
FPS-MPA1AJJ...............................129, 130
FPS-MPA1CJJ...............................129, 130
Index
Part Number Index
Part Number
Page
FPS-MPA1JJJ................................129, 130
FPS-MPA1SJJ...............................129, 130
O
OLH-MK072J00M0MKBA...................127
OLH-MK072J00M0MKCA...................127
OLH-MK072J00M0MKEA...................127
OLH-MM288J00M0MKBB...................127
OLH-MM288J00M0MKCB...................127
OLH-MM288J00M0MKEB...................127
OLH-MN432J00M0MKBB...................127
OLH-MN432J00M0MKCB...................127
OLH-MN432J00M0MKEB...................127
OLR-SJ12J00D1002A..........................129
OLR-SJ12J00D2002A..........................129
OLR-SJ12J00D3002A..........................129
OLR-SJ24J00D1002A..........................129
OLR-SJ24J00D2002A..........................129
OLR-SJ24J00D3002A..........................129
OPS-MPPACCRMPNL..........................129
OPS-MPPRACKMT24...........................129
OPS-MPPRACKMTCM..........................129
OSB-SBJ032000000.............................130
OSB-SBJ032A10000............................130
OSB-SBJ032G10000............................130
OSB-SBJ232000000.............................130
OSB-SBJ232A10000............................130
OSB-SBJ232G10000............................130
Q
QBCB-HR......................................... 22, 107
QCH-1RU..................................................105
QCH-2RU..................................................105
QCH-4RU..................................................105
QCPC-6ARSZB-XXYYM......................111
QCPC-6ARUZB-XXYYM......................111
QCPP-24MC6AS....................................109
QCPP-24MC6AU....................................109
QCPP-48MC6AS....................................109
QCPP-48MC6AU....................................109
QCPU-MCBM..........................................106
QCPU-MPPM-1.......................................110
QDR-1RU.................................................... 22
QDR-2RU.................................................... 22
QDR-4RU.................................................... 22
QFA-1FFM3ZNXXXMAA....................108
QFA-1FFM4ZNXXXMAA....................108
QFA-1WWSMZNXXXMAA.................108
QFA-2FFM3ZNXXXMAA....................108
QFA-2FFM4ZNXXXMAA....................108
QFA-2WWSMZNXXXMAA.................108
QFA-4FFM3ZNXXXMAA....................108
QFA-4FFM4ZNXXXMAA....................108
QFA-4WWSMZNXXXMAA.................108
Part Number
Page
QFA-8FFM3ZNXXXMAA....................108
QFA-8FFM4ZNXXXMAA....................108
QFA-8WWSMZNXXXMAA.................108
QFB-192FMPOMMHR..........................107
QFB-192FMPOSMHR...........................107
QFB-48FDLCMMMHR..........................107
QFB-48FDLCMSMHR...........................107
QFPC-MKKSMZAXXXM......................108
QFPC-MKKSMZBXXXM......................108
QFPC-MPPM3ZAXXXM.......................108
QFPC-MPPM3ZBXXXM.......................108
QFPC-MPPM4ZAXXXM.......................108
QFPC-MPPM4ZBXXXM.......................108
QUCH-1RU................................................. 22
QUCH-2RU................................................. 22
QUCH-4RU................................................. 22
QUFB-192FMPOMMHR......................... 22
QUFB-192FMPOSMHR.......................... 22
QUFB-48FDLCM4APHR........................ 22
QUFB-48FDLCM4ASHR........................ 22
QUFB-48FDLCMM3HR.......................... 22
QUFB-48FDLCMSMHR.......................... 22
QUFB-96FMM264APHR........................ 22
T
T310R50-GYYY-AP...............................266
TE310M100-GYYY-AP.........................266
TE310M50-GYYY-AP............................266
TE310R100-GYYY-AP..........................266
TE310R25-GYYY-AP............................266
TE310Z100-GYXX-AP..........................266
TE310Z150-GYXX-AP..........................266
TE510H-XXYY-AP.................................246
TE510HF-XXYY-AP...............................245
TE510M-XXYY-AP.................................246
TE510M25-XXYY-AP............................246
TE510R-XXII............................................246
TE510R25-XXYY....................................246
TE510Z1-XXYY-AP...............................246
TE510Z125-GYXX-AP..........................266
TE510Z125-XXYY-AP..........................246
TE510Z1F-XXYY-AP.............................245
TE61024M-XXYY-AP............................227
TE61024R-XXYY-AP.............................227
TE61024Z1-XXYY-AP..........................227
TE610M-XXYY-AP.................................227
TE610MF-XXYY-AP..............................226
TE610Z1-XXYY-AP...............................227
TE610Z1F-XXYY-AP.............................226
TE610Z3-XXYY-AP...............................227
TE610Z3F-XXYY-AP.............................226
TE620R-XXYY-AP..................................226
TE640MF-XXYY-AP..............................212
TE640RF-XXYY-AP...............................212
TE640Z1-XXYY-AP...............................212
Part Number
Page
TE640Z1F-XXYY-AP.............................212
TE640Z3F-XXYY-AP.............................212
X
X-1427431-1............................................161
X-1427431-2............................................161
X-1427431-3............................................161
X-1427431-4............................................161
X-1427431-5............................................161
X-1427431-6............................................161
X-1427432-1............................................161
X-1427432-2............................................161
X-1427432-3............................................161
X-1427432-4............................................161
X-1427432-5............................................161
X-1427432-6............................................161
X-1427433-1............................................161
X-1427433-2............................................161
X-1427433-3............................................161
X-1427433-4............................................161
X-1427433-5............................................161
X-1427433-6............................................161
X-1427434-1............................................161
X-1427434-2............................................161
X-1427434-3............................................161
X-1427434-4............................................161
X-1427434-5............................................161
X-1427434-6............................................161
X-1427435-1............................................162
X-1427435-2............................................162
X-1427435-3............................................162
X-1427435-4............................................162
X-1427435-5............................................162
X-1427435-6............................................162
X-1427436-1............................................158
X-1427436-2............................................158
X-1427436-3............................................158
X-1427436-4............................................158
X-1427436-5............................................158
X-1427436-6............................................158
X-1427437-1............................................158
X-1427437-2............................................158
X-1427437-3............................................158
X-1427437-4............................................158
X-1427437-5............................................158
X-1427437-6............................................158
X-1427438-1............................................158
X-1427438-2............................................158
X-1427438-3............................................158
X-1427438-4............................................158
X-1427438-5............................................158
X-1427438-6............................................158
X-1427439-1............................................158
X-1427439-2............................................158
X-1427439-3............................................158
318108AE 12/13 www.te.com/enterprise-asia
321
Index
Part Number Index
Part Number
Page
X-1427439-4............................................158
X-1427439-5............................................158
X-1427439-6............................................158
X-1427441-1............................................159
X-1427441-2............................................159
X-1427441-3............................................159
X-1427441-4............................................159
X-1427441-5............................................159
X-1427441-6............................................159
X-1427442-1............................................159
X-1427442-2............................................159
X-1427442-3............................................159
X-1427442-4............................................159
X-1427442-5............................................159
X-1427442-6............................................159
X-1427444-1............................................162
X-1427444-2............................................162
X-1427444-3............................................162
X-1427444-4............................................162
X-1427444-5............................................162
X-1427444-6............................................162
X-1427445-1............................................162
X-1427445-2............................................162
X-1427445-3............................................162
X-1427445-4............................................162
X-1427445-5............................................162
X-1427445-6............................................162
X-1427446-1............................................162
X-1427446-2............................................162
X-1427446-3............................................162
X-1427446-4............................................162
X-1427446-5............................................162
X-1427446-6............................................162
X-1427448-1............................................162
X-1427448-2............................................162
X-1427448-3............................................162
X-1427448-4............................................162
X-1427448-5............................................162
X-1427448-6............................................162
X-1427449-1............................................160
X-1427449-2............................................160
X-1427449-3............................................160
X-1427449-4............................................160
X-1427449-5............................................160
X-1427449-6............................................160
X-1427450-1............................................160
X-1427450-2............................................160
X-1427450-3............................................160
X-1427450-4............................................160
X-1427450-5............................................160
X-1427450-6............................................160
X-1427451-1............................................160
X-1427451-2............................................160
X-1427451-3............................................160
X-1427451-4............................................160
322
Part Number
Page
X-1427451-5............................................160
X-1427451-6............................................160
X-1427452-1............................................160
X-1427452-2............................................160
X-1427452-3............................................160
X-1427452-4............................................160
X-1427452-5............................................160
X-1427452-6............................................160
X-1427453-1............................................160
X-1427453-2............................................160
X-1427453-3............................................160
X-1427453-4............................................160
X-1427453-5............................................160
X-1427453-6............................................160
X-1427456-1............................................160
X-1427456-2............................................160
X-1427456-3............................................160
X-1427456-4............................................160
X-1427456-5............................................160
X-1427456-6............................................160
X-1427457-1............................................159
X-1427457-2............................................159
X-1427457-3............................................159
X-1427457-4............................................159
X-1427457-5............................................159
X-1427457-6............................................159
X-1427458-1............................................159
X-1427458-2............................................159
X-1427458-3............................................159
X-1427458-4............................................159
X-1427458-5............................................159
X-1427458-6............................................159
X-1859416-1............................................152
X-1859416-2............................................152
X-1859416-3............................................152
X-1859416-4............................................152
X-1859416-5............................................152
X-1859416-6............................................152
X-1859417-1............................................152
X-1859417-2............................................152
X-1859417-3............................................152
X-1859417-4............................................152
X-1859417-5............................................152
X-1859417-6............................................152
X-1859418-1............................................153
X-1859418-2............................................153
X-1859418-3............................................153
X-1859418-4............................................153
X-1859418-5............................................153
X-1859418-6............................................153
X-1859419-1............................................153
X-1859419-2............................................153
X-1859419-3............................................153
X-1859419-4............................................153
X-1859419-5............................................153
www.te.com/enterprise-asia 12/13 318108AE
Part Number
Page
X-1859419-6............................................153
X-1859420-1............................................153
X-1859420-2............................................153
X-1859420-3............................................153
X-1859420-4............................................153
X-1859420-5............................................153
X-1859420-6............................................153
X-1859421-1............................................153
X-1859421-2............................................153
X-1859421-3............................................153
X-1859421-4............................................153
X-1859421-5............................................153
X-1859421-6............................................153
X-1859422-1............................................154
X-1859422-2............................................154
X-1859422-3............................................154
X-1859422-4............................................154
X-1859422-5............................................154
X-1859422-6............................................154
X-1859423-1............................................154
X-1859423-2............................................154
X-1859423-3............................................154
X-1859423-4............................................154
X-1859423-5............................................154
X-1859423-6............................................154
X-1859424-1............................................154
X-1859424-2............................................154
X-1859424-3............................................154
X-1859424-4............................................154
X-1859424-5............................................154
X-1859424-6............................................154
Y-1
Y-1116412-X..................................268, 296
Y-1339123-X..................................268, 296
Y-1374416-X..................................268, 296
Y-1375092-X............................................308
Y-1375187-X............................................229
Y-1375190-X............................................247
Y-1375191-X............................................247
Y-1375192-X............................................267
Y-1375361-X..................................268, 296
Y-1375362-X..................................268, 296
Y-1375363-X..................................268, 296
Y-1375364-X..................................268, 296
Y-1375365-X..................................268, 296
Y-1375366-X..................................268, 296
Y-1427226-X............................................236
Y-1427266-X............................................236
Y-1427269-X............................................236
Y-1427275-X............................................254
Y-1427288-X............................................254
Y-1427289-X............................................254
Y-1427290-X............................................254
Y-1427305-X............................................254
Index
Part Number Index
Part Number
Page
Y-1427314-X............................................235
Y-1427363-X............................................236
Y-1435725-X............................................116
Y-1435726-X............................................116
Y-1435791-X............................................116
Y-1435796-X............................................116
Y-1435797-X............................................116
Y-1479181-X..................................268, 296
Y-1479190-X..................................268, 296
Y-1479191-X..................................268, 296
Y-1479230-X............................................297
Y-1479231-X............................................297
Y-1479232-X............................................297
Y-1499836-X..................................268, 296
Y-1499855-X..................................268, 296
Y-1711027-X............................................234
Y-1711040-X............................................252
Y-1711548-X............................................122
Y-1711563-X............................................210
Y-1711564-X............................................210
Y-1711579-X............................................206
Y-1711580-X............................................209
Y-1711613-X............................................208
Y-1711618-X............................................208
Y-1711623-X............................................208
Y-1711624-X............................................209
Y-1711637-X............................................207
Y-1711659-X............................................209
Y-1711666-X............................................234
Y-1711755-X............................................122
Y-1711756-X............................................122
Y-1711757-X............................................122
Y-1711758-X.............................................. 30
Y-1711760-X............................................122
Y-1711774-X.............................................. 30
Y-1711776-X............................................206
Y-1711777-X............................................234
Y-1711787-X............................................209
Y-1711789-X.............................................. 32
Y-1711815-X............................................217
Y-1711816-X............................................217
Y-1711817-X............................................217
Y-1711818-X............................................217
Y-1711819-X............................................217
Y-1711820-X............................................217
Y-1711825-X............................................216
Y-1711851-X............................................216
Y-1716029-X............................................157
Y-1859238-X............................................255
Y-1859239-X............................................255
Y-1859240-X............................................255
Y-1859242-X............................................255
Y-1859243-X............................................255
Y-1859246-X............................................237
Y-1859247-X............................................237
Part Number
Page
Y-1859249-X............................................237
Y-1859250-X............................................237
Y-1859251-X............................................237
Y-1859275-X............................................236
Y-1859277-X............................................236
Y-1859279-X............................................236
Y-1859280-X............................................236
Y-1859281-X............................................236
Y-1859300-X............................................236
Y-1859352-X............................................216
Y-1859513-X............................................217
Y-1859514-X............................................217
Y-1859516-X............................................217
Y-1859517-X............................................217
Y-1859518-X............................................217
Y-1859531-X............................................237
Y-1859532-X............................................237
Y-1859534-X............................................237
Y-1859535-X............................................237
Y-1859536-X............................................237
Y-1859622-X.............................................. 37
Y-1859623-X.............................................. 37
Y-1859624-X.............................................. 37
Y-1859625-X.............................................. 37
Y-1859690-X............................................254
Y-1859691-X............................................254
Y-1859692-X............................................254
Y-1859694-X............................................254
Y-1859695-X............................................254
Y-1920743-X.................................................6
Y-1933096-X............................................268
Y-1933096-X............................................296
Y-1933192-X..................................268, 296
Y-1933193-X..................................268, 296
Y-1933194-X..................................268, 296
Y-1933582-X..................................268, 296
Y-1933659-X..................................268, 296
Y-1933661-X..................................268, 296
Y-1933668-X............................................286
Y-1933671-X............................................286
Y-1933674-X............................................286
Y-1933748-X............................................229
Y-1933881-X............................................218
Y-1933882-X............................................218
Y-1933884-X............................................218
Y-1933885-X............................................218
Y-1933886-X............................................218
Y-2
Y-2055108-X.................................................6
Y-2055109-X.................................................6
Y-2055438-X............................................116
Y-2055576-X.................................................3
Y-2055577-X.................................................3
Y-2055578-X.................................................3
Part Number
Page
Y-2055579-X.................................................3
Y-2055580-X.................................................6
Y-2055581-X.................................................6
Y-2055584-X............................................173
Y-2055600-X.................................................6
Y-2055611-X.................................................3
Y-2055612-X.................................................3
Y-2055614-X............................................173
Y-2055623-X.................................................6
Y-2055624-X.................................................6
Y-2055666-X............................................173
Y-2055668-X............................................173
Y-2055670-X............................................173
Y-2055688-X............................................173
Y-2055704-X.................................................6
Y-2055711-X.................................................7
Y-2055712-X.................................................7
Y-2055713-X.................................................7
Y-2055714-X.................................................7
Y-2055715-X.................................................3
Y-2055716-X.................................................3
Y-2055726-X............................................173
Y-2055728-X............................................173
Y-2055741-X............................................173
Y-2105001-X............................................177
Y-2105002-X............................................177
Y-2105003-X............................................177
Y-2105004-X............................................177
Y-2105005-X............................................177
Y-2105006-X............................................177
Y-2105007-X............................................177
Y-2105008-X............................................177
Y-2105009-X............................................178
Y-2105010-X............................................178
Y-2105011-X............................................178
Y-2105012-X............................................178
Y-2105025-X............................................174
Y-2105026-X............................................174
Y-2105027-X............................................174
Y-2105028-X............................................174
Y-2105029-X............................................175
Y-2105030-X............................................175
Y-2105031-X............................................175
Y-2105032-X............................................175
Y-2105033-X............................................175
Y-2105034-X............................................175
Y-2105035-X............................................175
Y-2105036-X............................................175
Y-2105049-X............................................176
Y-2105050-X............................................176
Y-2105051-X............................................176
Y-2105052-X............................................176
Y-2105053-X............................................176
Y-2105054-X............................................176
Y-2105055-X............................................176
318108AE 12/13 www.te.com/enterprise-asia
323
Index
Part Number Index
Part Number
Page
Y-2105056-X............................................176
Y-2105057-X............................................176
Y-2105058-X............................................176
Y-2105059-X............................................176
Y-2105060-X............................................176
Y-2105061-X............................................174
Y-2105067-X............................................175
Y-2105072-X............................................175
Y-2105076-X............................................176
Y-2111366-X.............................................. 30
Y-2111367-X.............................................. 31
Y-2111370-X.............................................. 32
Y-2111371-X.............................................. 30
Y-2111521-X.............................................. 27
Y-2111522-X.............................................. 27
Y-2111615-X..................................268, 296
Y-2153052-X.............................................. 27
Y-2153078-X.............................................. 27
Y-2153140-X.............................................. 38
Y-2153141-X.............................................. 38
Y-2153142-X.............................................. 38
Y-2153150-X.............................................. 36
Y-2153151-X.............................................. 36
Y-2153152-X.............................................. 36
Y-2153230-X.............................................. 27
Y-2160046-X.................................................6
Y-2160047-X.................................................6
Y-2160048-X.................................................6
Y-2160052-X............................................116
Y-2160073-X.................................................3
Y-2160074-X.................................................3
Y-2160075-X.................................................3
Y-2160076-X.................................................3
Y-2160077-X.................................................7
Y-2160078-X.................................................7
Y-2160108-X.............................................. 10
Y-2160109-X.............................................. 10
Y-2160112-X.................................................6
Y-2160113-X.................................................6
Y-2160114-X.................................................6
Y-2160115-X.................................................6
Y-2160116-X.............................................. 10
Y-2160117-X.............................................. 10
Y-2160122-X.............................................. 10
Y-2160123-X.............................................. 10
Y-2160126-X.................................................6
Y-2160127-X.................................................6
Y-2160128-X.............................................. 10
Y-2160129-X.............................................. 10
Y-2160135-X.................................................5
Y-2160136-X.................................................5
Y-2160137-X.................................................9
Y-2160139-X.................................................5
Y-2160140-X.................................................5
Y-2160141-X.................................................9
324
Part Number
Page
Y-2160143-X............................................173
Y-2160145-X............................................173
Y-2160146-X.................................................6
Y-2160147-X.................................................6
Y-2160193-X.................................................5
Y-2160194-X.................................................5
Y-2160195-X.................................................9
Y-2160197-X.................................................5
Y-2160198-X.................................................5
Y-2160199-X.................................................9
Y-2160301-X.............................................. 96
Y-2160302-X.............................................. 96
Y-2160304-X.............................................. 15
Y-2160305-X.............................................. 15
Y-2160349-X............................................174
Y-2160404-X............................................174
Y-2160510-x.............................................. 16
Y-2160588-X............................................174
Y-2160593-X............................................131
Y-2160594-X............................................131
Y-2160608-X.............................................. 12
Y-2160609-X.............................................. 12
Y-2160663-X.............................................. 12
Y-2160664-X.............................................. 12
Y-3
Y-336488-X..............................................207
Y-5
Y-558198-X..............................................308
Y-558199-X..............................................308
Y-558821-X..............................................308
Y-569523-X..............................................259
Y-569524-X..............................................259
Y-569526-X..............................................259
Y-569527-X..............................................259
Y-569528-X..............................................259
Y-569669-X..............................................259
Y-569685-X..............................................259
Y-599142-X..............................................156
Y-599144-X..............................................157
Y-599145-X..............................................157
Y-599146-X..............................................157
Y-599148-X..............................................157
Y-599149-X..............................................157
Y-599602-X..............................................157
Y-599603-X..............................................157
Y-6
Y-6206650-X............................................156
Y-6695240-X............................................201
Y-6695242-X............................................201
Y-6695244-X............................................201
www.te.com/enterprise-asia 12/13 318108AE
Y-9
Y-969556-X..............................................287
Index
Reliable Performance
ISO Cat. 6A
An augmented Category 6 specification
All products in this catalog that feature the ISO Cat. 6A seal are compliant with the global
cabling standard ISO/IEC 11801 Amendment 2.
This amendment defines specifications for Cat. 6A components and Class EA permanent links.
These global Cat. 6A / Class EA specifications require a generation of connecting hardware
offering far superior performance compared to the existing products which are based on the
American TIA standard.
Benefits of this higher standard include more headroom, “mix & match” capability, enabling
short links, and removing the requirement for ANEXT testing.
Ensured Performance
Optimized Physical Contact (OPC) enhances your link parameters
Why do you require a controlled ferrule end face? Enhanced services such as Gigabit, 10
Gigabit and soon 40/100 Gigabit Ethernet require a high quality cabling system. Therefore,
IEC 608749 specifies the dimensional details of fiber optic connectors in order to ensure
interoperability and performance within an ISO 11801 specified application. These dimensional
requirements are directly related to the endface characteristics of a polished ferrule, namely
its radius, dome offset and fiber position.
If these ferrule characteristics are optimal, an Optimized Physical Contact (OPC)
between the two connectors is guaranteed. This will enhance data transmission parameters
like optical performance, Attenuation, Return Loss and data link stability.
Also, the optical interoperability between connectors of different suppliers can be ensured
by controlled endfaces. As a result of OPC a stable physical contact between the endfaces
is achieved. This provides a very low Insertion Loss as well as a high Return Loss in order to
run high speed applications like 10/40/100 Gigabit Ethernet. All products in this catalog that
feature the Ensured Performance logo provide OPC at all time. AMP NETCONNECT
guarantees a controlled endface for all OM3, OM4 and OS2 assemblies and field installable
products (MT-RJ and LightCrimp Plus).
318108AE 12/13 www.te.com/enterprise-asia
325
Index
Reliable Performance
Universal Connectivity Platform
Rack efficiency and multiple media deployment
The Universal Connectivity Platform (UCP) is designed to deliver rack efficiency and multiple
media deployment. It comprises a versatile range of components that include patch panels,
subfloor panel and overhead panel mounts, pre-terminated links and adaptor modules. One
common patch panel, either angled or flat, is used to accommodate both copper and fiber,
and the units can be installed within or outside the 19-inch envelope. Side mounting brackets
maximize usable space along the vertical posts of the rack system, while adaptive mounting
brackets can be used strategically above and below the racks.
The UCP accepts pre-terminated copper assemblies, fiber cassettes and MRJ21 high density
copper connectivity cassettes, for faster deployment and high reliability. It is also fully
compatible with TE Connectivity’s AMPTRAC managed connectivity solution.
Products which can be used inside the Universal Connectivity Platform are marked with the
UCP Compatible seal.
RoHS Ready
Restriction on the Use of Hazardous Substances
TE Connectivity will support your RoHS requirements. We’ve assessed more than 1.5 million
end items/components for RoHS compliance, and issued new part numbers where required in
the process of eliminating the restricted materials. All part numbers in this catalog are RoHS
compliant. These products comply with European Union Directive 2002/95/EC as amended
1 January 2006 that restricts the use of lead, mercury, cadmium, hexavalent chromium, PBB,
and PBDE in certain electrical and electronic products sold into the EU as of 1 July 2006.
NOTE: For purposes of this catalog, included within the definition of RoHS Compliant are:
lP
roducts that are clearly “Out of Scope” of the RoHS Directive such as hand tools
and other non-electrical accessories.
l Products that contain lead in solderable interfaces (they do not contain any of the
other five restricted substances above allowable limits). However, these products
are covered by an application-based exception for lead in solders, such as the
server, storage, or networking infrastructure exemption of the same directive.
NOTE: Information regarding RoHS compliance is provided based on reasonable inquiry of
our suppliers and represents our current actual knowledge based on the information
provided by our suppliers. This information is subject to change.
326
www.te.com/enterprise-asia 12/13 318108AE
RoHS
Ready
HOW CAN I
SAVE SPACE IN
MY DATA CENTER?
USE LESS RACKSPACE
MAXIMIZE FIBER UTILIZATION
INCORPORATE FLEXIBILITY
DEPLOY HIGH DENSITY CABLING
24
Fib
10
er MPOptim
at
e
s
b/
, 40
G
0
& 10
THE FOUNDATION OF YOUR AGILE DATA CENTER
INFRASTRUCTURE FOR THE NEXT THREE GENERATIONS
The 24 Fiber MPOptimate system delivers future proof,
high density and modular connectivity for
10, 40 and 100Gb/s data center applications.
te.com/enterprise-asia/24fiber
N
LAUNOW
CH
IN AS ING
IA
TE BROADBAND NETWORK SOLUTIONS REGIONAL SALES HEADQUARTERS:
North America
Greensboro, NC, USA
Ph:+1-800-553-0938
Fx:+1-717-986-7406
Latin America
Buenos Aires, Argentina
Ph:+54-11-4733-2200
Fx:+54-11-4733-2282
Europe
Kessel-Lo, Belgium
Ph:+32-16-35-1321
Fx:+32-16-35-2188
Mid East & Africa
Cergy-Pontoise, France
Ph:+33-1-3420-2122
Fx:+33-1-3420-2268
Asia
Hong Kong, China
Ph:+852-2735-1628
Fx:+852-2735-1625
Pacific
Sydney, Australia
Ph: +61-2 8748-9500
Fx: +61-2 9748-8487
TE BROADBAND NETWORK SOLUTIONS IN ASIA:
China
Ph:+86-400-820-6015
Hong Kong
Ph:+852-2735-1628
Fx:+852-2735-1625
Indonesia
Ph:+62-21-2929-3800
Fx:+62-21-2929-3899
Japan
Ph:+81-44-844-8071
Fx:+81-44-844-8732
Korea
Ph:+82-2-3415-4551
Fx:+82-2-3486-1787
Malaysia
Ph: +603-7806-3055
Fx: +603-7805-2831
Philippines
Ph:+63-2-988-9400
Fx:+63-2-846-6180
Singapore
Ph:+65-6590-5049
Fx:+65-6482-1012
Taiwan
Ph:+886-2-8768-2788
Fx:+886-2-8768-3469
Thailand
Ph:+66-2-834-6200
Fx:+66-2-955-0513
Vietnam - HCMC
Ph:+84-8-3823-8473
Fx:+84-8-3823-8533
Vietnam - Hanoi
Ph: +844-6277-9651
Fx: +844-6277-9655
OFFICE NETWORK SOLUTIONS
Contact us:
Please contact us at one of the regional
offices shown above.
TE Connectivity:
www.te.com/enterprise-asia
TE Connectivity, TE Connectivity (logo), Tyco Electronics, and TE (logo) are trademarks of the TE Connectivity Ltd. family of companies
and its licensors.
While TE Connectivity has made every reasonable effort to ensure the accuracy of the information in this document, TE Connectivity does
not guarantee that it is error-free, nor does TE Connectivity make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. TE Connectivity reserves the right to make any adjustments to the information contained herein at
any time without notice. TE Connectivity expressly disclaims all implied warranties regarding the information contained herein, including,
but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are
for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult
TE Connectivity for the latest dimensions and design specifications.
Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved.
318018AE 12/13 Update © 2013
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising