Industrial Managed Gigabit Ethernet Switches EHG7504/EHG7508

Industrial Managed Gigabit Ethernet Switches EHG7504/EHG7508
■ The opening to the sides are for the device’s heat
1. Grounding Screw
Inside the package you will find the following items:
■ Industrial Managed Gigabit Ethernet Switch x 1
■ 4-Pin 5.08mm Lockable Terminal Block (Already mounted to the device) x 1
3. RS-232 Console
4
2
■ 5-Pin 5.08mm Lockable Terminal Block (Already mounted to the device) x 1
5
6
3
7
■ Protective caps for all SFP and PoE ports (Depend on purchased model)
8
■ Installation Guide with Warranty Card x 1
EHG7504/EHG7508 Series
EHG7604/EHG7608 Series
4. Relay Output 1 with current carrying
capacity of 1A@24 VDC (Normal Open)
■ DIN-Rail Kit (Already mounted to the device) x 1
Industrial Managed Gigabit Ethernet Switches
2. DIP Switches
1
5. Relay Output 2 with current carrying
capacity of 1A@24 VDC (Normal Open)
6. Frame Ground
7. Terminal for Power 1
Never install or work on electrical or cabling during periods of lightning activity.
Never connect or disconnect power when hazardous gases are present.
8. Terminal for Power 2
Warning:Hot Surface Do Not Touch. RESTRICTED ACCESS AREA: The equipment
should only be installed in a Restricted Access Area.
dissipation please never obstruct or cover them
with any objects or try to insert them through it.
■ This switch’s factory IP by default is 10.0.50.1 you
can access the device by its Web UI once it is
connected to a physical network (or using
Management Utility, for more information on
Management Utility, please refer to its manual).
Please be aware that the PC needed for this
procedure needs to be in the same
subnet, or
you may refer yourself to the device User’s
Manual.
Caution: CLASS 1 LASER PRODUCT. Do not stare into the laser!
1. If you have purchased the wall mount kit,
This equipment should be installed indoor and not connect directly with equipment
installed outdoor.
Indoor
proceed to place the screws on the back
of the device as show in (Fig. 1).
2. Although internal grounding has been
done inside, in order to ensure overall
maximum performance and protect your
Front View
Version 1.2
Updated in November, 2016
EHG7504-2SFP
EHG7504-2POE-2SFP
EHG7604
EHG7604-4POE
EHG7604-2SFP
EHG7604-2POE-2SFP
1
1
2
4
3
5
7
8
2
4
9
6
EHG7504-4SFP
EHG7604-4SFP
1
3
5
7
8
2
4
9
6
EHG7508
EHG7508-8POE
EHG7508-4SFP
EHG7508-4POE-4SFP
come into contact and damage your
EHG7608
EHG7608-8POE
EHG7608-4SFP
EHG7608-4POE-4SFP
there is a terminal for Frame Ground, you
1
grounding or you may opt to connect to
1
3
5
P1
P2
ALM
Green
Red
device, it is still strongly advised to ground
the device properly; hazardous ESD can
EHG7504
EHG7504-4POE
Name Color
7
8
2
4
3
5
7
8
2
4
9
6
3
5
7
8
9
RUN
Green
Ring
Green
equipment. On the power terminal block,
can choose whether to connect it to the
R.M.
Green
ed at all times ) (Fig. 2)
10
11
SFP
1
11
10
11
10
11
Green
3. You can then choose whether to plug in the other
peripheral ports at this point or do it later depending
on the actual location of the device or level of
PoE
Amber
comfort for performing such operation.
Remeber to plug in the protective caps for the
1. Reset button
7. PWR1 LED
2. Ring LED
8. PWR2 LED
3. RUN LED
9. PoE LEDs
4. Ring Master LED
10. 1000 BASE-X SFP Slots
to mount the whole device as shown in (Fig.
5. Alarm LED
11. 10/100/1000 BASE-T(X) RJ-45 Ports and/or
3).Proceed to (Fig. 4) if you want to remove the
6. SFP Ports LEDs
unused SFP and PoE ports.
2
1
4. Once the plate has been firmly put in place, proceed
device from DIN-Rail.
10/100/1000 BASE-T(X) PoE RJ-45 Ports
5. Next we can then proceed to connect the device to
the LAN (switch or PC, depending on the case), take
care on using the RJ-45 connector; after this we can
P/N:89900488G
2
then proceed to the device’s settings
Message
On
Power is being supplied through this power input
Off
Power is not supplied through this power input
On
Alarm is triggered by user defined events
Off
Alarm is not triggered by user defined events
Blinking
AP firmware is running normally
On/Off
System is not ready or halt
On
the grounding screw next to the terminal
block ( the one chosen should be connect-
Status
Amber
LAN
Green
Blinking
All the Rings are running normally
Ring is in protection state
Off
Ring is disabled
On
The device is a Master of the Ring
Off
The device is a Slave of the Ring
On
Port is linked
Blinking
Data is transmitting on this port
Off
No data is transmitting on this port
On
Power is being supplied to a Powered Device (PD)
Off
Power is not supplied to a PD
On
Ethernet is connected at 1000Mbps
Blinking
Ethernet is connected at 100Mbps
Off
Ethernet is connected at 10Mbps
On
Ethernet is connected
Blinking
Off
Data is transmitting on this port
Ethernet is disconnected
DIP Switch
Each device has two power requirements. For Non-PoE models, 9-57VDC can be
maximum system power consumption is 10W under DC input. Each PoE port will
1
consume up to 15.4W (802.3af) or 30W (802.3at). Please add up the numbers
and choose a power supply wisely.
2
ON
Ring active
OFF
Ring inactive
ON
Master
OFF
Slave
ON
3
OFF
4
OFF
5
6
OFF
Compatible Ring
ON
iA-Ring
OFF
ERPS Ring
Warranty Conditions
Front View
Function
DIP Switchtch
supplied to PWR1 and/or PWR2. For PoE models, 45-57VDC should be supplied
under 802.3af mode and 51-57VDC should be supplied under 802.3at mode. The
Warranty Policy
EHG7504
EHG7504-4POE
EHG7504-2SFP
EHG7504-2POE-2SFP
EHG7604
EHG7604-4POE
EHG7604-2SFP
EHG7604-2POE-2SFP
EHG7504-4SFP
EHG7604-4SFP
Products supplied by Atop Technologies are covered in this warranty for
EHG7508
EHG7508-8POE
EHG7508-4SFP
EHG7508-4POE-4SFP
EHG7608
EHG7608-8POE
EHG7608-4SFP
EHG7608-4POE-4SFP
sub-standard performance or defective workmanship. The warranty is not,
however, extended to goods damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock, earthquake
(c) Use of unqualified power supply, connectors, or unauthorized parts/kits
(d) Replacement with unauthorized parts
RMA and Shipping Costs Reimbursement
Customers shall always obtain an authorized "RMA" number from Atop before
shipping the goods to be repaired to Atop. When in normal use, a sold product
ON
Apply Profinet settings
shall be replaced with a new one within 3 months after purchase. The shipping
OFF
Apply standard switch settings
cost from the customer to Atop will be reimbursed by Atop.
Reserve for future use
*Settings are applied when the device is restored to default.
After 3 months and still within the warranty period, it is up to Atop whether to
replace the unit with a new one; normally, as long as a product is under warranty,
all parts and labor are free of charge to the customers.
After the warranty period, the customer shall cover the cost for parts and
Field Maintenance and Service
If the device requires servicing of any kind, you may need to disconnect and
remove it from its mounting. The initial installation should be done in a way that
makes this as convenient as possible.
■ Voltage/Power lines should be properly insulated as well as other cables. Be
careful when handing the so as to not trip over
■ Do not under any circumstance insert foreign objects of any kind into the heat
dissipation holes located in the different faces of the device. This may not only
harm the internal layout but might cause harm to you as well.
■ Do not under any circumstance open the device for any reason. Please
contact your dealer for any repair needed or follow the instructions on section
of your User’s Manual.
labor.Three months after purchase, the shipping cost from the customer to Atop
will not be reimbursed, but the shipping cost from Atop to the customer will be
paid by Atop.
Limited Liability
Atop shall not be held responsible for any consequential losses from using Atop’s
product.
Warranty Period
Product Categories
Warranty
Ethernet Switches
Product Categories
Warranty
DIN-Rail Power Supplies
Wireless
Power Adaptors
Serial Device Servers
Modbus Gateways
Antennas
Media Converters
Other Accessories
Embedded Device Servers
The warranty certification will not be effective until an authorized stamp issued by
Atop’s overseas agents.
Purchase Date:
/
/
(yyyy/mm/dd)
Serial Number
Atop Customer Services and Supports
1. Please contact your local dealers or Atop Technical Support Center at the
following numbers.
+ 886-3-550-8137 (Atop Taiwan)
+ 86-21-6495-6232 (Atop China)
2. Please report the defected problems via Atop’s Web site or E-mail account
Web Site:www.atop.com.tw, e-mail:service@atop.com.tw
Web Site:www.atop.com.cn, e-mail:service@atop.com.cn
─ Any changes to this material will be announced on Atop website. ─