- No category
advertisement
N E W
Datasheet
Network components in IP67
Industrial Ethernet for field wiring
8-port unmanaged switch in IP67
8-port managed switch in IP67
Industrial Ethernet directly on the machine with simple and safe M12 plug-in connectors. Weidmuller provides managed and unmanaged switches as well as cables and plug-in connectors.
• Designed for the most extreme environments
• Integrated IP67 housing
• M12-D-coded plug-in connector
IE-switches
• Redundant voltage supply
• Configuration via Web browser or via RS232 connection
• Redundancy through RapidRing™ protocol (switching time <300 ms)
• Port blocking, port filtering, port set-up
• QoS on VLAN basis, port basis, MAC basis,
IP type of service (TOS), DiffServ
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
I n d u s t r i a l E t h e r n e t f o r f i e l d w i r i n g
8-port unmanaged switch in IP67
Just 54 mm wide
One LED per port for link / speed / data
Fault relay:
1 x M12 A-coded, 5-pole
(24 V DC / 1 A)
8 x M12 D-coded, 4-pole
2 x MultiCard markers or 1 long 40 mm for labelling
Redundant voltage supply
2 x M12 A-coded, 5-pole
2-hole mounting and functional ground terminal
Switches are the central components of a network. They prevent data collision, allow rapid packet switching and enhance data throughput. Weidmuller switches meet the demands placed on the Fast Ethernet with its transmission rate of up to 100 Mbit/s, and they are downward compatible with the older networks that have a transmission rate of 10 Mbit/s (IEEE 802.3). They recognize the speed automatically.
Weidmuller’s unmanaged switches are Plug & Play devices for easy installation of Ethernet networks.
For direct connection to the network in the field,
Weidmuller now offers an IP 67 switch with eight Ethernet ports for use in harsh environments.
• Robust plastic housing (IP67 ingress protection class) for use in the field, complying with UL94 flammability rating V0
• Strip markers – wide range of marking systems and products
• Eight Ethernet ports with M12-D-coded plug-in connectors
• Temperature range from –40 °C to +60 °C
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Unmanaged switch
• IP67 housing
• M12-D-coded plug-in connector
IE-SW8-IP67
8 ports
I n d u s t r i a l E t h e r n e t f o r f i e l d w i r i n g
201
210
Technical data
Housing
Ports
AC input voltage, min.-max.
DC input voltage, min.-max.
Input power AC / DC
Input frequency
Operating temperature, min.-max.
Storage temperature, min.-max.
Installation
Ingress protection class
Standard
Data rate
Segment length
Functionality
Flow control full duplex
Status indication
Buffer memory
Address memory en je 8 Por
Aging
Length x width x height, mm (in)
Ordering data
Type
IE-SW8-IP67
Plastic
8x M12 D-Coded
8-24
10-36 V DC max. 5 W
47 - 63 Hz
-40 °C ... 60 °C (-40 °F ... 140 °F)
-40 °C ... 85 °C (-40 °F ... 185 °F)
Wall
IP 67
IEEE 802.3, 802.3u, 802.3x
10BASE-T/100BASE-TX
Copper 100 m
Auto-negotiation, redundant voltage supply, fault relay for PLC support half duplex/full duplex
Power;Link;Status;Run
256 KBytes
4K MAC addresses s
300 s
210 x 54 x 31 (8.27 x 2.13 x 1.22)
Part No.
8877190000
5
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
I n d u s t r i a l E t h e r n e t f o r f i e l d w i r i n g
8-port managed switch in IP67
Just 54 mm wide
One LED per port for link / speed / data
Fault relay:
1 x M12 A-coded, 5-pole
(24 V DC / 1 A)
8 x M12 D-coded, 4-pole
Serial interface (RS232)
1 x M12 B-coded, 5-pole
2 No. MultiCard markers or 1 No. 40 mm long strip for printing IP addresses
Redundant voltage supply
2 x M12 A-coded, 5-pole
2-hole mounting and functional ground terminal
For decentralized development of industry networks, many applications require a central switch. Weidmuller’s managed switches enable networks to be structured in order to optimize transport routes and times for network traffic. All Weidmuller switches are protocol transparent.
Each port forms both a network segment and a collision domain that are intrinsic to the port itself. The entire network bandwidth is available to each of these segments.
This results in enhanced network performance not only over the network as a whole, but also in each individual segment.
The features of the managed IP67 switch from Weidmuller include the following:
• Port trunking
• Port mirroring
• VLAN IEEE 802.1Q
• Filtering and forwarding table with fixed entries
• Selective multicast control
• Quality of service
• Configurable relay functions
• Access to the address table
• Configuration via Web interface or terminal program
• SNMP V.1-capability
• RSTP and RapidRing™
• IGMP snooping with querier functions
• Auto-crossing, auto-negotiation, auto-polarity
• Broadcast limitation
• Flow control IEEE 802.3x
• DHCP
• RMON (statistics, history, alarms, occurrences)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Managed switch
• IP67 housing
• M12-D-coded plug-in connector
IE-SW8-M-IP67
8 ports
I n d u s t r i a l E t h e r n e t f o r f i e l d w i r i n g
Technical data
Features
Ports
AC input voltage, min.-max.
DC input voltage, min.-max.
Input power AC / DC
Input frequency
Operating temperature, min.-max.
Storage temperature, min.-max.
Data rate
Segment length
Functionality
Flow control
Status indication
Buffer memory
Address memory
Approvals
Aging
Length x width x height, mm (in)
Ordering data
Type
IE-SW8-M-IP67
Accessories
Type
Programming cable RS232 on M12
201
210
SNMP V1 / Rapid Ring / RSTP 802.3w
IGMP Snooping / Querier
Port Mirroring / Port Filtering
Port Setup Functionality
Trunking / VLAN / QoS / TOS / Diffserv
MAC-based trunking
Auto-crossover / Autopolarity
Filtering and forwarding table
8x M12 D-Coded
8-24 V AC
10-36 V DC max. 5 W
47 - 63 Hz
-40 °C ... 60 °C (-40 °F ... 140 °F)
-40 °C ... 85 °C (-40 °F ... 185 °F)
10BASE-T/100BASE-TX
Copper 100 m
Auto-negotiation, redundant voltage supply, ring structure; fault relay for PLC support half duplex/full duplex
Power;Link;Status;Run
256 KBytes
4K MAC address
CE, cULus
300 s
210 x 54 x 31 (8.27 x 2.13 x 1.22)
Part No.
8877200000
Part No.
8874290000
5
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
I n d u s t r i a l E t h e r n e t f o r f i e l d w i r i n g
Accessories
M12
JPOVP Cat.5 M12
Ethernet Cat.5
M12
Technical data
Plug-in connector
Version
Coding
Pin
D
No. of poles 4
Cable construction (Cat.5/Class D) – PROFINET
Cable cross-section, mm
Conductor cross-section, mm
2
Strand construction, mm
2
Storage temperature, mm
Drain wire, mm
2
Overall shield (cable)
6.5 (2x2x AWG/7)
4 x 0.75
7 x 0.25
1.5
Aluminium shield (overlapping), 0.13 mm
Copper wires, covering approx. 85 %
Blue, orange, white, yellow Strand color
Sheathing color
Sheathing material
Green
PUR
Mechanical parameters
Storage temperature, °C (°F)
Operating temperature, °C (°F)
Minimal bending radius, mm
Weight, kg/km
Electrical parameters
Loop resistance, Ohm/km
Signal propagation delay, ns/m
Insulation resistance, MOhm *km
Impedance 1-100 MHz, Ohm
UL rating, kg/km
Surface transition impedance
10 MHz, mOhm/m
Test voltage, kg/km
Note
–50 up to +70 (–58 up to +158)
–20 up to +60 (–4 up to +140)
7.5 x Ø repeated, 5 x Ø single
61
≤120
≤ 5.3
≤ 500
100 ± 15
600
≤ 10
2000
L in the dimensional drawing is the line length
Ordering data
Connecting cables Type
Plug (straight) to plug (straight) 1.5 m IE-C5CD4U001.5-M12SM12S
3.0 m IE-C5CD4U003.0-M12SM12S
5.0 m IE-C5CD4U005.0-M12SM12S
10.0 m IE-C5CD4U010.0-M12SM12S
Connectors
Plug
Socket
Socket
4-pole D-Coded SAISM-4/8S-M12-4P D-COD
4-pole D-Coded SAIBM-4/8S-M12-4P D-COD
5-pole A coded SAIBM-5/8S-M12-5P-A-COD
4-pole D coded 90° SAISW-4/8S-M12-4P D-ZF Plug
Adapters
RJ45 to D-Coded M12 90°
RJ45 to D-Coded M12 Straight
IE-M12 Adap a
IE-M12 Adap b
M12 D-Coded Coupler
Tools
Screwty® tool
Stripping tools
IE-M12 Coup
Screwty for M12
AM 12
Configuration cable managed Switch
RS232 Sub-D to M12 IE-C-RS232-M12
Accessories
M12 Protective Cap SAI-SK-M12-UNI
Part No.
8877610015
8877610030
8877610050
8877610100
1892120000
1892130000
1784750000
1803930001
8901630000
8901620000
8901640000
1900000000
9030060000
8874290000
2330260000
Technical data
Rated voltage
Operating voltage (DC), max.
Rated discharge current per path (8/20) µs
Total discharge current, max (8/20) µs
DC response voltage
Attenuation
Response time
Rated current
Protection level, signal line, wire to wire/PE
Protection level, supply, wire to wire/PE
General data
Operating temperature, °C (°F)
Overvoltage category
Pollution severity
Type of connection
Approvals
Dimensions
Length x width x height mm
Note
Ordering data
30 V AC/DC
30 V
5.00 kA
10 kA
230 V
<0.3 dB at 250 Hz
≤ 5 ns
0.20 A
130 V/600 V
80 V/300 V
–25 up to +60 (–4 up to +140)
III
2 to IEC 61076-2-101-AI; M12 - plug/plug,
D-coded
CE
57 x 36 14.4
Each cable 1.5 m long
Type
JPOVP M12 D-coded Cat5
Part No.
8805570000
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]