Catalog Edition 20 Vol 1
Table of Contents
Page
Index
Digital Multimeters and Current Probes
1–3
Temperature/ Humidity Testers & Thermometers
4– 8
Temperature Alarms & Controls
9 – 11
Vacuum & Pressure Gauges
12 – 13
Specialty Instruments
14 – 15
Data Loggers
16 – 20
Chart Recorders
21 – 28
Tools & Accessory Testers
29 - 30
See our Full Line Catalog (Edition 18) for our complete product offering.
PRODUCT CATALOG
Edition 20 Volume 1
Published by
Sealed Unit Parts Co., Inc.
© 2003 Printed in U.S.A.
No part of this publication shall be reproduced
in whole or part by anyone without permission of:
SEALED UNIT PARTS CO., INC.
PO Box 21, 2230 Landmark Place
Allenwood, New Jersey 08720 USA
Phone (732) 223-6644 Fax (732) 223-1617
www.supco.com
Index
Model No.
Page
Model No.
Page
Model No.
RCB1
Page
31
10475
12
DPGT THRU DPGT220US
10740
12
DR5
25
RW516 THRU RWA10
29
13495
10
DSP990
5, 6
S6N1
29
14265
10
DT12
4, 6
SCCP, SCDM
2
12261 - 14265
20
DT22
4, 6
SD45C7 - SR120F7
22
24H3.5BAR THRU 24H35BAR
23
E20120F12 THRU E545C31
28
SL200C
20
24H50PSI THRU 24H500PSI
23
ELD
30
SL4
31D50PSI THRU 31D500PSI
23
EVENT-6H THRU EVENT-31D
23
SLCASE
27
31H3.5BAR THRU 31H35BAR
23
FBP100
31
SO45C7 THRU S20120F24
23
401 - 401JF220
11
FCO810 THRU FC2224
30
SR6N1
29
6H3.5BAR THRU 6H35BAR
23
FCR6
30
ST01 - ST10
6H50PSI THRU 6H500PSI
23
FPT10 THRU FPT15
30
SW25 - SW100
10, 20
7D50PSI THRU 7D500PSI
23
FUSE10
2
TA2 - TA2220C
9, 10
2
TA2PROBE
7H3.5BAR THRU 7H35BAR
23
FUSE2
23, 24
30
FUSEA
2
TA3 - TA3WM
CABLE10T
23, 24
FWB1
31
TA3P
CABLE6 THRU CABLE25
23, 27
HK7
29
TA4 - TA4T
HTHL10
20
TA4P
BJ10
CC6
CO1000
27
14, 15
CP50
2, 3
CPA20
2
CPO70
2, 3
HTP5 THRU HTP5100
23, 24
TA6 - TA6C220
26-28
8
10
10, 11
10
9, 10
10
9, 11
29
TA6PROBE
10
IM1 THRU IMK3
30
TA7 - TA7C
9, 11
JS1
29
TA7PROBE
10
HVT2
23
KEL
23, 24
TAL2
10
CR15 THRU CR100
23, 24
KES
23, 24
TAP4 - TAP4C220
11
CR4
26-28
KEV
23, 24
TC1
30
30
CR1000-1 THRU CR1000-24
CR4CABLE
27
KPP
26-28
TC2
23
KTE
26-28
TCW25 THRU TCW100
CR87B - CR87B220C
21, 24
KTH
26-28
THC200
5, 6
CR87E - CR87E220
22, 25
26-28
THP1
5, 6
5, 6
23
CR87-1 THRU CR87-60
KTP
10, 23, 24
CR87HT - CR87HT22C
21, 24
KTT
26-28
THP2
CR87P - CR87PB220
22, 24
L420
16 - 20
THP5
CR87PA
23, 24
LCV
16 - 20
TLA
2
CR87V - CR87V220
22, 25
2
CRPEN THRU CRPENR
23-24, 27
LIT8 thru LIT8LT
7
TP10K
LITH9B
20
TP15
23, 24, 27
27
CRPP2-1 THRU CRPP2-24
28
LLS
16, 20
TP6
CRT
27
LPT
16 - 20
TPA1
2
7
TPFDA
27
LT2
16 - 20
TPFG
4, 6
CRTP2-1 THRU CRTP2-72
28
LTC
16 - 20
TPM110 - TPM220C
5, 6
CRTT2-2 THRU CRTT2-23
28
LTH
16 - 20
TPOC
4, 6
CT1
30
LTT
16 - 20
TPP
4, 6
CTC3
15
M500
14, 15
TPS
4, 6
CTP1
30
M501
14, 15
TTP5
23
DAM1
14, 15
MCASE
14
UFC1
30
DDT2
4, 6
MFD10
14, 15
USBS
10, 20
14
UW1
29
14
V20120F12 THRU V3010C31
CRT THRU CRT220UK
CRT220
DHS55
23, 24
LPT260 - LPT600
15
MFDCASE
DLTP6
20
MFDFUSE
DM10/DM10T
1, 3
NEMA
DM20
1, 3
P85
23, 24
VG60 THRU VG66
28
12, 13
29
VGC
12
29
29
DM25
1, 3
P89
29
WG1
DM40
1, 3
PC6
27
WIN100
DPG500
13
PT100
4, 6
12, 13
RA25
10
DPGT
4, 6, 20
Digital Multimeters & Current Probes
Digital Multimeters
SUPCO’s full line of Digital Multimeters (DMM’s) provide
electrical measurement needs for all of your applications.
• Thermocouple Voltages in Furnaces
• AC/DC Line and Control Voltages
• Flame Safeguard Current (DM25 0.01 resolution)
• Frequency (Hz) in systems and panels (DM40)
• Continuity Checks
DM20
Digital Multimeter
New!
The DM20 Digital Multimeter (DMM)
provides general electrical measurements
for most applications. It's sturdy design
and protective rubber boot provide reliable
measurements to meet your needs.
• Thermostat Heat Anticipator Current
• Heating Element Resistance
• Run and Start Capacitor verification
• Motor Winding Resistance
DM25
Digital Multimeter
with Capacitance
The DM25 Digital Multimeter (DMM) provides
electrical measurements for your HVAC
applications, including Capacitance and 0.01 DC
µ Amps resolution for your flame safeguard
measurements. It's sturdy design and protective
rubber boot provide reliable measurements to
meet your needs.
Features/Benefits
• 750 Volts AC
• 1000 Volts DC
• 20 MegaOhms Resistance
• Continuity
• 10 Amps AC
• 10 Amps DC
• Large Display
• Data Hold
• 3 Year Warranty
Features/Benefits
• 750 Volts AC
• 1000 Volts DC
• 40 MegaOhms Resistance
• Continuity
• 10 Amps AC
• 10 Amps DC
• 20,000 µ F Capacitance
• .01 µ mA DC Resolution
• Data Hold
• 3 Year Warranty
New!
DM10/DM10T
Economy Digital Multimeters
with Temperature (DM10T)
The DM40 True rms Digital Multimeter
(DMM) provides the most accurate
electrical measurements for your HVAC
applications. It's sturdy design and
protective rubber boot provide reliable
True rms measurements to meet your
needs.
The DM10 and DM10T Digital Multimeters
provide an economical solution to your
everyday electrical and temperature (DM10T)
measurement needs.
• AC/DC Volts
• AC/DC Amps
• Resistance
• Continuity
• Capacitance
• Triple Readout Display
• 4000 Count Display
• Backlight for Display
• Sleep Mode
• Min/Max Record
• Relative Mode
• 3 Year Warranty
1
New!
DM40
True rms
Digital Multimeter
Features/Benefits
New!
Features/Benefits
• 1000 Volts DC
• Continuity
• 2M W Resistance
• 10 Amps DC
• 750 Volts AC
• Temperature
(DM10T)
Digital Multimeters & Current Probes
New!
New!
CP50
Digital Current Probe
CPO70
Open Jaw Multi Probe
The CP50 Digital Current Probe provides current
measurements for most applications. It also
measures other general electrical parameters.
Measures and displays current and voltage
simultaneously. Quick and easy current
measurement with open jaw design.
Applications
Features/Benefits
Features/Benefits
• HVAC Equipment consumption
• Branch circuit current
• AC Line and Control Voltages
• Continuity Checks
• 400 Amps AC
• 4 K-Ohms Resistance
• 600 Volts AC
• 4 Volts DC
• Peak Hold
• Data Hold
• 1 1/8” Jaw Capacity
• Continuity
• 3 Year Warranty
• Simultaneously measures up to 200 Amps
AC Current and one of the following:
- 600V max AC or DC Voltage
- 40 MegaOhm max Resistance
- 200uF Capacitance
- up to 1 kHz Frequency
• Two LCD displays
• Open Jaw Current Measurement
• 3 year Warranty
Optional Accessories
New!
New!
New!
2
CPA20
AC Current Probe Adapter
TPA1
Temperture Adapter
TLA
Test Leads
The CPA20 Current Probe adapter is
designed to measure AC current. It can
be used with most digital multimeters
having a 20mA and 200mA or 40mA and
400mA AC range.
The TPA1 Temperature Adapter can be
used with digital multimeters having
200mV or 2V DC ranges and analog
multimeters having DCmV ranges up
to 300mV DC.
Features/Benefits
Features/Benefits
• Two ranges: 40A and 400 A
• 1 1/8” Jaw capacity
• 4 foot cable length
• Measures up to 500°F
• Uses K-type thermocouple
SCDM/SCCP
Soft Deluxe Case
• 1000V AC or DC max
• 10 Amps max
Features/Benefits
• Rugged Cordura Case
• Zippered case
• Sturdy belt loop
• Identification window
Digital Multimeters and Current Probe Accessories
DM10T
DM20
DM25
DM40
CP50
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
CPO70
Standard Accessories (Included)
TLA
TP10K
FUSE2
FUSE10
9 V Battery
FUSEA
Test Leads w/ Alligator Clips
Temperature Probe
2A, 600 V Fuse
10A, 600 V Fuse
*
0.5A, 600 V Fuse
Optional Accessories
TPA1
CPA20
SCDM
SCCP
Temperature Adapter
Current Probe Adapter
Soft Carrying Case for DMM’s
Soft Case for Current Probes
*
*
*
*
Digital Multimeters & Current Probes
Digital Multimeters and Current Probe Specifications
Volts AC
DM10/ DM10T
750
DM20
750
DM25
750
DM40
650
CP50
600
CP070
600
Volts AC Best Resolution
Volts DC
1V
1000
0.1 mV
1000
0.1 mV
1000
0.1 mV
1000
1.0 mV
4
1mV
600
Volts DC Best Resolution
Amps AC
0.1 mV
0.1 mV
10
0.1 mV
10
0.1 mV
10
1.0 mV
400
0.1mV
200A
0.1 mA
10
0.1 mA
10
0.1 mA
10
0.01 A
100mA
10
0.1 mA
0.1 mA
0.01 mA
0.1 mA
Amps AC Best Resolution
Amps DC
Amps DC Best Resolution
Frequency (Hz)
9.999MHz
Frequency Best Resolution
Base Accuracy (DC Volts)
± 0.5% ± 2 dgts
± 0.5% ± 2 dgts
± 0.5% ± 1 dgt
± 0.3% ± 2 dgts
± 1.5% ± 4 dgts
0.001Hz
± 1.2% ± 2 dgts
Resistance max. (Ohms)
2M
20 M
40 M
40 M
(AC Amps)
4K
± 3.0% ±3 dgts (AC Amps)
40M
Continuity
Capacitance
Yes
Yes
Yes
20,000mF
Yes
10,000mF
Yes
Yes
200µF
0.1 mF
0.01 mF
4000
Yes
4,000 plus bar graph
Capacitance Best Resolution
Temperature
-4 °F to 2498° F (DM10T)
Temperature Accuracy
Display (Count)
Data Hold
1pF
(-20° C to 1370 °C) (DM10T)
±3 ± 2 digits
2000
2000
Yes
Peak Hold
Sleep Mode
Yes
Min/Max Record
Relative Mode
Yes
Yes
4,000
Yes
Yes
Yes
Operating Temp.
32° F to 74° F
(0°C to 23°C)
Storage Temp.
32°F to 104°F
(0°C to 40°C)
32°F to 104°F
(0°C to 40°C)
32°F to 114°F
(0°C to 40°C)
32°F to 122°F
(0°C to 50°C)
14°F to 122°F
(-10°C to 50°C)
14°F to 122°F
(-10°C to 50°C)
14°F to 122°F
(-10°C to 50°C)
-4°F to 140°F
(-20°C to 60°C)
-4°F to 140°F
(-10°C to 60°C)
(-30°C to 60°C)
Relative Humidity
Fuse Protection
0% to 75% RH
mA: 0.2A/ 250V
0% to 80% RH
mA: 2A/600VAC
A: 10mP/600VAC
0% to 80% RH
mA: 2A/600VAC
A: 10mP/600VAC
0% to 80% RH
mA: 0.5mP/600VAC
A: 10mP/600VAC
0% to 80% RH
0% to 90% RH
Power
Battery Life (Typical)
9 V Battery (included)
9 V Battery (included)
200 hours
9 V Battery (included)
200 hours
9 V Battery (included)
100 hours
9 V Battery (included)
200 Hours
2 AA Batteries
(included)
Size (HxLxW)
1.3″ x 3.4″ x 7.4″
1.3″ x 3.4″ x 7.4″
1.3″ x 3.4″x 7.4″
7.13″ X 2.63″X 1.25″
(33mm x 86mm x 187mm) (33mm x 86mm x 187mm) (33mm x 86mm x 187mm)
Weight
Warranty
23.3 oz (660g)
3 Year
The New SUPCO DM25 digital
multimeter being used to
troubleshoot an electric furnace.
23.3 oz (660g)
3 Year
23.3 oz (660g)
3 Year
19 oz.
3 Year
3
Temperature & Humidity Testers
Digital Thermometers
Applications
• Superheat Measurements (T1-T2)(DT22)
• Oven Temperature measurements
New!
• Ambient Temperature measurements
• Surface Temperature measurements
DT12
Digital Thermometer
• Food Service
• Measure HVAC and Refrigeration system Temperatures
New!
DT22
Dual Digital Thermometer
The full ranging DT12 Digital Thermometer
comes complete with a K-type thermocouple
oven clip probe and is housed in a sturdy
rubber boot for accurate and reliable
temperature measurements.
The Dual Input DT22 Digital Thermometer
comes complete with two (2) K-type thermocouples. Providing Temperature Differential
Measurement (T1-T2), it is ideal for superheat
applications.
Features/Benefits
Features/Benefits
• K-Type Thermocouple Probe with Oven Clip
Included
• Range -112°F to 1832°F
(-80°C to 1000°C)
• Protective Rubber Boot Included
• Low Battery Indicator
• 3 Year Warranty
• Two (2) K-Type Thermocouple Probes Included
• Range -328°F to 2462°F
(-200°C to 1350°C)
• Temperature Differential Measurement (T1-T2)
• K-Type and J-Type Thermocouple Selectable
• Min/Max Record
• Data Hold
• Protective Rubber Boot Included
• Auto Shut Off
• Low Battery Indicator
• 3 Year Warranty
DDT2
Digital Differential
Thermometer
With it’s Dual Display, the DDT2 provides instant
measurements for two Temperature points
(T1,T2) and their difference (T1-T2).
Optional PC Software (DDT2S) allows for analysis
of trend data.
4
Features/Benefits
• Dual K-Type Thermocouple Inputs
• Temperature Differential Measurement (T1-T2)
• Records Up to 8 Min/Max/Avg Measurements
• Relative Function provides instant Temperature
Difference between successive measurements
• Dual Display
• Auto-Ranging
• Data Hold
• Auto Power Off
• Vinyl Case Included
TPFDA
FDA Approved K-type
Thermocouple Probe
TPOC
K-type Thermocouple
Probe with Oven Clip
PT100
Digital Pocket Surface Thermometer
Applications
• Speedy recovery - reclaim temperature measurement
• Measures evaporator plate and condensing temperatures
• Air inlet, outlet and surrounding air
Features
• Ultra sensitive air and surface reading probe
• Provides fast response—within seconds
• Temperature “HOLD” switch—keeps readings fixed
TPFG
Fiberglass Insulated K-type
Thermocouple Probe
TPP
K-type Thermocouple
Piercing Probe
TPS
K-type Thermocouple Surface
Probe
Temperature & Humidity Testers
Temperature & Humidity Testers
New!
New!
The THP1 and THP2 provide quick measurement of
temperature and humidity for a multitude of applications.
THP1
Thermo-Hygrometer Pen
THP2
Thermo-Hygrometer Pen
THC200
Thermo-Hygrometer w/ Clock
Features/Benefits
Features/Benefits
Features/Benefits
• Measures Temperature & Humidity, Simultaneously
• Dual Display
• Temperature in °F or °C
• Auto Power Off (20 min.)
• RESET Switch
• HOLD Switch
• Belt or Pocket Clip
• Battery Included
• Min/Max Memory
• Measures Temperature & Humidity,
Simultaneously
• Dual Display
• Temperature in °F or °C
• Pocket Clip
• Battery Included
• Min/Max Memory
• Table top or wall mount
• Measure Temperature and Humidity
Simultaneously
• Real Time Clock
• Set High and Low Alarms for Temperature and
Humidity
• Temperature Range: -4°F to 122°F
(-20°C to 50°C)
• Humidity Range: 25% to 95%
• °F/C° Switchable
DSP990
Digital Psychrometer
5
The DSP990 is a precision temperature & humidity
instrument. It provides measurement of Temperature,
Humidity, Wet Bulb and Dew Point
• No Water Necessary
• No Twirling
• No Reading Charts
Applications
• Cellophane
• Laboratory
• Textile
• Photographic
• Snowmaking
Features/Benefits
• Chemical
• Pharmaceuticals
• Paper
• Printing
• Tobacco
• Min/Max
• Data Hold
• °F/°C Switch
• Auto Power Off
• Reset Button
• Low Battery Indicator
• Pocket Sized
• Protective Cover
• One Year Warranty
TPM110
Temperature Indicator
A highly reliable, extremely accurate temperature indicator. Custom
designed faceplates with your company name or logo are available
with quantity orders.
Applications
Features/Benefits
• Direct replacement for old style 2 1/4″ and 2 1/2″ dial gauges
• Commercial Refrigeration/Freezer Panels
• Hospital/Laboratory Control Panels
• Large LCD display
• Easy installation
• Thermocouple wire can be extended to 500'
• Can calibrate in the field
Model No.
TPM110
TPM110C
TPM220
TPM220C
TPM12
TPM12C
110 VAC
110 VAC
220 VAC
220 VAC
12 VAC
12 VAC
Fahrenheit Model
Celsius Model
Fahrenheit Model
Celsius Model
Fahrenheit Model
Celsius Model
Temperature & Humidity Testers
Specifications
DT12
DT22
DDT2
PT100
TPM110
# of inputs
1
2
2
1
1
Thermo -
K
K, J
K
THP1
THP2
DSP990
1 Temp./1 Hum. 1 Temp./1 Hum.
THC200
1 Temp./1 Hum.
J
couple Type
Differential
*
*
Data Hold
*
*
*
*
Min/ Max
*
*
*
*
*
*
Dual Display
Auto-Off
Temp. Range
*
*
*
-112°F to 2462°F
K-Type
-328°F to 2498°F
-80°C to 1000°C
Temp.
Resolution
Temp.
Accuracy
*
*
PT100/PT100C
-70°F to 199°F
-4°F to 122°F
-4°F to 122°F
-4°F to 122°F
-10°C to 50°C
-20°C to 50°C
-20°C to 50°C
-20°C to 50°C
1.0°F
0.1°F
0.1°F
1.0°F
1.0°F
±1°F
±1.8°F
±2°F
±1.8°F
±1.8°F or 1.0°C
5% to 95% RH
10% to 90% RH
0 to 100% RH
25% to 95% RH
0.1% RH
1% RH
1% RH
1% RH
±3% for
±5% for
±3% for
±5% RH
-40°F to 199.9°F -56.67°C to 93.28°C
-80°C to 1000° C
-40°C to 93.28°C
J-Type
PT100H/PT100HC
-40°F to 250°F
-200°C to 1000°C
-40°C to 120°C
0.1°F
0.1°F
0.1°F
0.1°F
-112°F to 299°F
-328°F to 999.9°F
-200°F to 200°F
-40°F to 199.9°F
1°F (300 +°F)
1°F (1000 +°F)
1°F otherwise
1.0°F (-40° to 250°F)
±0.5% Rdg +1.8°F ±0.3% Rdg +1.8°F ±0.5% Rdg+2°F
0.2 Surface
(-58°F to 1832°F)
*
14°F to 122°F
-112°F to 2462° F -200°C to 1370°C
-328°F to 1832°F
*
Triple Display
1.0 Air
Humidity
Range
Humidity
6
Resolution
Humidity
Accuracy
Power
AAA (2)
1.8" x 6" x 3"
10% to 90% RH,
otherwise ±5% otherwise ±7%
otherwise ±4%
9V Alkaline
9V Alkaline
9V Alkaline
120/240V
Button cell (1)
Button cell (1)
50/ 60 Hz
CR2032
LR44
1.8" x 6" x 3"
7.25" x 2.5" x 1.4"
1.5" x 6.75" x 0.8"
3.38" X 3.38"
1 year
1 year
Batteries
Size (HxLxW)
10% to 90% RH, 40% to 80% RH,
Weight
7.2 oz
7.2 oz
7.4 oz
Warranty
3 year
3 year
1 year
1 year
AAA (2)
AA (2)
Batteries
Batteries
6.7" X 1.85" X 0.5"
4.38" X 2.75" X 0.5"
1 year
1 year
1 year
Temperature Probe Specifications
Thermocouple Type
Temp. Range:
Subminiature connector
4' bead tip probe with
FDA approved insulation
3.7" heavy duty chisel tip insertion probe
with handle and 4' cord
4" heavy duty spring loaded tip surface
probe with handle and 4' cord
TPFDA
TPFG
K-Type
-40°F to 950°F
-40°C to 510°C
*
K-Type
-40°F to 950°F
-40°C to 510°C
*
TPOC
with Oven Clip
K-Type
-40°F to 950°F
-40°C to 510°C
*
TPP
Piercing
K-Type
-58°F to 482°F
-50°C to 250°C
*
*
*
*
TPS
Surface
K-Type
-58°F to 1202°F
-50°C to 650°C
*
Thermometers
Laser Infrared Thermometers
Laser Infrared Thermometers offer precise, non-contact measurement in a lightweight,
handheld instrument. With one hand operation, they are ideal for a wide variety of applications.
Applications
• Refrigeration Systems
• Heating Systems
• Supply and Return Registers
LPT600/LPT260
Easy Temp
Laser Thermometer
• 3:1 optical ratio
• 1 button operation
• Carrying case included
• Circuit Breaker Panels
• Motors/Bearings
• Transformers
• Ducts
• And More
New!
LIT8LT
Low Temperature Laser
Infrared Thermometer
LIT8B New!
Laser Infrared
Thermometer
• 8:1 optical ratio
• Trigger style
• Backlight
• Low temperature reading to -58°F
• 8:1 optical ratio
• Trigger style
• Backlight
LIT8
Laser Infrared
Thermometer
• 8:1 optical ratio
• Miniature size
• Carrying case included
• Backlight
7
Temperature Range
Resolution
Accuracy
Emissivity
Distance Factor
Sample Rate
Display
Automatic shut off
Power Supply
Weight
Dimensions
LPT600
LPT260
0°F to 600°F
-67°F to 260°F
(-18°C to 315°C)
(-55°C to 125°C)
1°F (1°C)
±2% Accuracy ±0.5% of reading,
plus one digit repeatability
0.95 fixed
D:S =3:1 with a 1" min. target
LIT8B
-4°F to 518°F
(-20°C to 270°C)
1°F (1°C)
±2% of reading or 4°F/2°C
LIT8
-4°F to 788°F
(-20°C to 420°C)
1°F (1°C)
±2% of reading or 4°C
LIT8LT
-58°F to 932°F
(-50°C to 500°C)
1°F (1°C)
±2% of reading or ±2°F/±2°C
0.95 fixed
D:S = Approximately 8:1
0.95 fixed
D:S = Approximately 8:1
LCD
*
9V Battery (Included)
LCD with backlight
*
9V Battery (Included)
5.8 ounces (180g)
6.4" X 3.2" X 2.4"
(159mm X 79mm X 57mm)
0.95 fixed
D:S = Approximately 8:1
1 second
LCD with backlight
*
9V Battery (Included)
6.4 ounces (200g)
6.7" X 1.7" X 1.6"
Application Note:
What is Distance to Spot Ratio (D:S)?
This is the size of the measurement
field that a non-contact infrared
thermometer uses to provide a
temperature reading. The infrared
thermometer averages the temperature
of that field to calculate the temperature
reading. For example, a D:S ratio of 8:1
means that the measurement field measures
approximately 1 foot in diameter when the
target is approximately 8 feet away.
LCD with backlight
*
9V Battery (Included)
5.9 ounces (185g)
6.4" X 3.2" X 2.4"
(159mm X 79mm X 57.2mm)
Thermometers
Pocket Digital Thermometers
Applications
• Refrigerators/Freezers
• Food Processing/Prep.
• Heating/Ventilating
ST09
ST10
• -40°F to 392°F (-40°C to 200°C)
• Accuracy: +/-2°F between -14°F to 212°F
(+/-1°C between -10°C to 100°C)
• Min/Max
• F°/C° Switch
• Protective Sheath
• ON/OFF Switch
• Data Hold
• Pocket Clip
• Battery Included (STBAT)
• Drop Resistant
• Waterproof
• -50°F to 305°F
(-45°C to 150°C)
• Accuracy: +/-2°F or +/-1°C
• F°/C° Switch
• Large LCD
• Display updates every second
• Battery included. Free spare
battery (STBAT)
• Pocket clip
• 4 23/32" (12cm) stainless
steel stem
Pocket Dial Thermometers
8
Part
No.
ST01
ST02
ST07
ST08
Dial
1"
1"
1 3/4"
1 3/4"
ST01
ST02
ST07
ST08
• 1" dial
• 5" stem
• °F only
• Recalibration adjustment
• 1 3/4" dial
• 5" stem
• °F and °C
• Recalibration adjustment
Stem
5"
5"
5"
5"
Temperature
Range
-40°F to 160°F
0°F to 220°F
0°F to 220°F (-18°C to 105°C)
-40°F to 160°F (-40°C to 70°C)
Application
Refrigerators/Freezers
Air Conditioners
Air Conditioners
Refrigerators/Freezers
Appliance Thermometers
ST03
ST04
ST06
• Horizontal design
• Stainless steel wire clips
for easy hanging
• °F and °C
• Stainless Steel Construction
• Hangs or stands
• °F and °C
• Unbreakable lens
Part
No.
ST03
ST04
ST06
Temperature
Range
-20°F to 80°F
100°F to 600°F
-40° to 80°F
(-30°C to 27°C)
(38°C to 315°C)
(-40° to 27°C)
Application
Refrigerators
Ovens
Refrigerators/Freezers
Temperature Alarms & Controls
All of your temperature sensitive areas are protected with the broadest line of temperature alarms:
single and dual set point, wireless remote, battery operated and multi-channel. Select the right one
for your application.
Applications
Features/Benefits
• Food Markets, Convenience Stores, Supermarkets
• Restaurants, Florists, Greenhouses
• Laboratories, Pharmaceutical Storage Facilities
• Refrigerated Transport, Cold Storage Facilities
• Computer Rooms
• Adjustable alarm temperature ranges
• Audible and visual alarm
• Built-in terminals for remote alarm or
telephone dialer connection (except TA7)
• Alarm switch for ‘No delay’ or ‘1 hour delay’
TA2
Single Set Point Temperature Alarm
TA4
Wireless Remote Temperature Alarm
A reliable, inexpensive alarm for refrigerators and
freezers. Just flip a switch to activate alarm on a rise or
fall in temperature.
No wires to run – The remote transmitter uses existing 120 VAC lines to
send the alarm signal to the receiver. Use one receiver for up to 20
different transmitters. Switch activates alarm on a rise or fall in temperature.
Model No.
TA2
TA2C
TA2-220
TA2-220C
Model No.
TA4
120 VAC Fahrenheit Model
120 VAC Celsius Model
220 VAC Fahrenheit Model
220 VAC Celsius Model
TA4R (option)
TA4T (option)
Complete System
(includes 1 transmitter and 1 receiver)
Receiver
Transmitter
TA6
Dual Set Point Temperature Alarm
TA7
Battery Operated Temperature Alarm
Alarms on a rise AND fall in temperature.
For sensitive temperature applications in remote areas, this
battery operated unit is inexpensive and easy to install.
Alarms on rise in temperature only.
Model No.
TA6
TA6C
TA6220
TA6C220
120 VAC Fahrenheit Model
120 VAC Celsius Model
220 VAC Fahrenheit Model
220 VAC Celsius Model
Model No.
TA7
Farenheit Model
TA7C
Celsius Model
9
Temperature Alarms & Controls
TA3
Digital Temperature Alarm
TAL2
Dual Temperature Alarm Logger
This panel mounted temperature alarm with digital
display provides both an audible and visual alarm.
Alarms on rise or fall in temperature.
Set high and low alarms for two (2) temperature sensitive applications, and track
their temperature trends, simultaneously.
Alarm Functions
Logger Functions
Model No.
TA3
TA3C
TA3-220
TA3C220
TA3WM
• Audible alarm & Relay contacts
• Relay contacts can connect to remote
alarm dialer
• Programmable alarm delay
• Alarm event storage (up to 45 events)
• Programmable interval (1 sec. to 18 hrs.)
• Data rollover
• Store 32,250 (single temp.) or 16,125(dual
temp.) data points
• Battery backup
• Software included
• Minimum System Requirements: 8MB of
RAM, 2M of disk space, 800 x 600
resolution, 1 free COM port or a free USB
port (optional USB interface is required,
p/n USBS)
120 VAC
120 VAC
220 VAC
220 VAC
Fahrenheit Model
Celsius Model
Fahrenheit Model
Celsius Model
Wall Mount Bracket, optional
Temperature Alarm Specifications
10
Alarm Channels
Alarm Adjustment Range
Probe
Sensor Type
Maximum Probe extension
Temperature Accuracy (Display)
Maximum Transmit/Receive Range
Operating frequency
Remote Alarm Connections
Power
Battery Backup
Case
Mounting
Dimensions
Weight
Warranty
TA2
1
-10°F to 80°F
(-25°C to 30°C, Celsius model)
Encapsulated sensor with 6 ft. cord
Thermistor
200 ft.
TAL2
2
-40°F to 60°F and 0°F to 100°F
(-18°C to 38°C and -40°C to 16°C, Celsius model)
Encapsulated sensor with 15 ft. cord
Thermistor
300 ft.
Screw type, 120 VAC,
5 Amps (dry contacts)
120 V AC (220 V optional)
TA4
1
-10°F to 80°F
(-25°C to 30°C, Celsius model)
Encapsulated sensor with 6 ft. cord
J-Type Thermocouple
200 ft.
1500 feet (must use the same electrical lines)
100KHz
Screw type 120 VAC,
0.1 Amp max., (dry contacts)
120 V AC (220 V optional)
Normally open (N.O.). Closed on alarm.
48 volts, 100mA maximum
110V or 220V power adapter supplied (p/n 14950)
9V alkaline battery (not included)
Hi-impact thermoplastic
Surface, external holes provided
3" x 4 7/8" x 1 5/8"
13 oz
1 year
Hi-impact thermoplastic
Surface, external holes provided
3" x 4 7/8" x 1 5/8"
24 oz
1 year
3" x 2.5" x 1.1"
2.5 oz
1 year
Accessories
SW25
SW50
SW75
SW100
TCW25
TCW50
TCW75
TCW100
TA3P
TA4P
TA2PROBE
TA6PROBE
TA7PROBE
14265
RA25
25’ Extension Wire
50’ Extension Wire
75’ Extension Wire
100’ Extension Wire
25’ Type J Thermocouple Wire
50’ Type J Thermocouple Wire
75’ Type J Thermocouple Wire
100’ Type J Thermocouple Wire
Probe w/ 6’ Type J Thermocouple Wire
Probe w/ 6’ Type J Thermocouple Wire
Probe w/ 6’ extension wire
Probe w/ 6’ extension wire
Probe w/ 4’ extension wire
Replacement Sensor
Remote Audible Alarm w/ 25’ extension
USBS
13495
USB to Serial Interface
Serial Port Cable
TA2
TAL2
*
*
*
*
*
*
*
*
TA4
TA6
TA7
*
*
*
*
*
*
*
*
*
*
*
*
TA3
TAP4
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
401
*
*
*
*
*
*
*
Temperature Alarms & Controls
401
Digital Set Point
Temperature Controller
A completely self-contained 120/220
VAC, ON/OFF temperature controller
with digital display.
TAP4
Four (4) Probe Temperature Alarm
Specifications
• Refrigeration temperature control
• Temperature alarm
• Temperature indication
• Furnace temperature control
Sensor
Scale
Display
Accuracy
Adjustable differential
Control mode
Maximum load current
Power Consumption
Supply voltage
Operating temperature
Panel mounting
Features
Set alarms for 4 separate temperature applications. Provides a
quick alert for a multitude of temperature problems.
Model No.
TAP4
TAP4-220
TAP4C
TAP4C-220
Applications
-40°F to 60°F; 0°F to 100°F, 120V
-40°F to 60°F; 0°F to 100°F, 220V
-18°C to 38°C; -40° C to 16°C, 120V
-18°C to 38°C; -40° C to 16°C, 220V
• LCD display of the set point and sensor
temperatures
• Includes 15 ft. of Type J thermocouple
wire with a 4 inch long stainless steel
sensor
• 10 Amp Relay Contacts
• Rear terminal strip for all connections
• Front Panel LED indicates relay is
energized
• Energize relay on rise or fall of
temperature
Thermocouple Type J (included)
0° to 1200°F or -20°C to 1100°C
LCD
±1%FS
1° to 25° Centered around set point
ON-OFF
10 Amp, 250 VAC Resistive SPDT Relay
2 VAC
120 VAC or 220 VAC, 50/60Hz.
32°F to 140°F (0° to 60°C)
3 5/8" x 1 13/16" Cut-out
(92mm x 45mm)
Model No.
401JF
401JC
401JF220
401JC220
110 VAC Fahrenheit Model
110 VAC Celsius Model
220 VAC Fahrenheit Model
220 VAC Celsius Model
TA6
2
-10°F to 80°F
(-25°C to 30°C, Celsius model)
Encapsulated sensor with 6 ft. cord
Thermistor
200 ft.
TA7
1
-10°F to 80°F
(-25°C to 30°C, Celsius model)
Encapsulated sensor with 6 ft. cord
Thermistor
100 ft.
±2°F at 75°F ambient
TA3
1
-50°F to 170°F
(-30°C to 96°C, for Celsius model)
Encapsulated sensor with 6 ft. cord
J-Type Thermocouple
2000 ft.
TAP4
4
-40°F to 60°F and 0°F to 100°F
(-18°C to 38°C and -40°C to 16°C, Celsius model)
Encapsulated sensor with 15 ft. cord
Thermistor
300 ft.
Screw type, 120 VAC,
5 Amp max., (dry contacts)
120 V AC (220 V optional)
None
Hi-impact thermoplastic
Surface, external holes are provided
3" x 4 7/8" x 1 5/8"
13 oz
1 year
Hi-impact thermoplastic
Surface, adhesive pads/keyhole slot
5 3/4" x 1 1/2" x 1"
5 oz
1 year
Screw type 120 VAC,
0.1 Amp max., (dry contacts)
120 V AC (220 V optional)
9V alkaline battery (not included)
Panel mount
Face panel (1 3/4" x 3 5/8" cut out required)
1 11/16" x 3 9/16" x 5 3/16"
24 oz
1 year
Terminal strip screw connection 120VAC,
5 Amps max., (dry contacts)
110V or 220V power adapter supplied
9V alkaline battery (not included)
NEMA 3 Type
Surface, keyhole or recessed screws
6" x 7 1/2" x 3"
1.9 Lbs (0.86kg)
1 year
9 V alkaline battery (not included)
Application Note:
Many supermarkets have added free standing,
portable case displays for seafood, sushi, sandwich preparation, bakery goods and more. These
cases are not tied to the central monitoring system. The TAP4 is an ideal instrument for preventing food spoilage in these areas. It’s inexpensive,
easy to install and monitors up to 4 different temperature sensitive applications.
11
Vacuum & Pressure Gauges
New!
VGC
Vacuum Gauge Coupler
Insures leak free connection to vacuum
gauge during measurement
VG64
Digital Vacuum Gauge
Suitable for field or laboratory use, the VG64 delivers high
precision at a low price.
Features/Benefits
• Ultra fine resolution: (1 Micron when vacuum ≤ 200 Microns)
• Reads vacuum in 7 international units
• Display updates every 1/2 second
• Convenient built in hanger
• Cleaning port provides quick cleaning and drying of sensor
Accessories
Part No.
10475
120 volt power adapter
10740
Soft Pouch
VG60
Electronic Vacuum Gauge
VG61
Electronic Vacuum Gauge
10 segment color coded LED readout provides
fast response of vacuum measurements.
• Enjoy the same features as the VG60 in
a durable hard case. Sensor cord
extends to 5 feet.
Features/Benefits
12
• Pocket size—only 5 1/2" x 1 3/4" x 1 1/2"
• Cleanable sensor
• Single switch operation
• Low battery indication
• Color coded LED display
• Built-in hanger
• Soft case included (MFDCASE)
Features/Benefits
• Cleanable sensor
• Single switch operation
• Low battery indication
• Color coded LED display
Accessories
Part No.
DPGT
120 V Power Adapter
New!
VG65
Professional Series
Digital Vacuum Gauge
New!
VG66
Professional Series
Analog Vacuum Gauge
Same great specifications as the
VG64 in a rugged service case
Features/Benefits
• Vacuum range 50 – 5000 microns
• 5 inch Analog meter
• Cleanable Vacuum Sensor
• 500 psi maximum overpressure
• Low battery indicator
• Expandable sensor cord (up to 6 feet)
• Sensor cord extendable using standard
telephone cord
• Rugged Service case
Vacuum & Pressure Gauges
Vacuum Gauge Specifications
VG64
Thermistor
VG60
Thermistor
VG61
Thermistor
VG65
Thermistor
VG66
Thermistor
Connector Type
Standard ¼ inch
male flare fitting.
Standard ¼ inch
male flare fitting.
Standard ¼ inch
male flare fitting.
Standard ¼ inch
male flare fitting.
Standard ¼ inch
male flare fitting.
Vacuum Range
0 – 12,000 Microns
(0 – 1,600 Pascals)
50 – 5,000 Microns
50 – 5,000 Microns
0 – 12,000 Microns
(0 – 1,600 Pascals)
10 – 5,000 Microns
Scale
Microns, PSI, InHg, milliBars,
Pascals, Torr, milliTorr
Microns - 10 LED segments from
atmosphere to 50 Microns
Microns - 10 LED segments from
atmosphere to 50 Microns
Microns, PSI, InHg, milliBars,
Pascals, Torr, milliTorr
Microns, Torr
Resolution
0-200: 1 Micron
201-500: 5 Microns
0-200: 1 Micron
201-500: 5 Microns
501-1,000: 10 Microns
1,001-2,000: 50 Microns
501-1,000: 10 Microns
1,001-2,000: 50 Microns
2,001-5,000: 250 Microns
5,001-8,000: 500 Microns
2,001-5,000: 250 Microns
5,001-8,000: 500 Microns
Operating Temperature Range
8,001-12,000: 1,000 Microns
35°F to 125°F ( 2°C to 52°C)
8,001-12,000: 1,000 Microns
35°F to 125°F ( 2°C to 52°C)
Overpressure
Accuracy
500 PSI Max (20 Bar)
±10% (50-1000 Microns)
500 PSI Max (20 BAR)
500 PSI Max (20 BAR)
500 PSI Max (20 BAR)
±10% (50-1000 Microns)
500 PSI Max (20 BAR)
Power Source
9 V Alkaline Battery
(not included)
9 V battery
(not included)
9 V battery
(not included)
9 V battery
(not included)
9 V battery
(not included)
Auto Shutoff
Dimensions
Yes
5 1/2" x 3" x 1 1/4"
No
5 1/2" x 1 3/4" x 1 1/2"
No
Yes
5 1/2" x 3" x 1 1/4"
N/A
9 1/4" x 7 1/2" x 2 3/4"
Weight
6.7 oz
6.8 oz
6.7 oz
2 1/4 lb.
Sensor Type
DPG500
Digital Pressure Gauge
13
The DPG500 Digital Pressure Gauge is an
extremely accurate, pressure gauge that
operates on a standard 9 Volt battery or 120
VAC With its universal pressure sensor, it can
measure presssure in a liquid, gas, steam
and more.
Features/Benefits
Application Note:
CONNECTING THE VG64 TO THE VACUUM SYSTEM
A vacuum guage should be connected to the vacuum
system at the vacuum port. The "Auxiliary Port" is primarily
for cleaning and should normally be closed with the
supplied cap. It is possible to connect the vacuum gauge
in-line, however, it may restrict flow and increase the
evacuation time.
CHECKING HVAC SYSTEMS FOR LEAKS
When checking a system for leaks use only copper tubing
and a vacuum proof valve. Generally, standard hoses will not
hold a vacuum. If using the blank-off valve on the vacuum
pump check it for leaks periodically. At the beginning of the
test the vacuum gauge reading may increase due to a
system equalization. The vacuum reading should hold after
a minimum of 5 minutes. If the reading continues to
increase it may indicate a leak in the system.
• Universal Pressure Sensor (Liquid, Gas,
Steam, etc...)
• Range: -14 to 500 PSI
• Large 1/2" high LCD display
• 9 Volt battery operation
• Concealed battery compartment
• Accessible zero adjustment screw
• Power saving “ON-OFF” switch
• Standard 1/8" N.P.T. brass male connection
Specifications
Scale
Operating
temperature range
Accuracy
Full Range Scale
Resolution
Display
Power
Pressure port
Size
Patent No. 4777827
-14 to 500 PSI
32°F to 120°F
Better than 1%
Used with steam/gas/water/air/fluids
1 PSI
0.5" LCD
9 V battery or 120 VAC with adapter
1/8 NPT male
3 7/32" x 3 1/4" x 1 1/2"
Standard Accessories
1/8" N.P.T. to 1/4" Flare brass adapter fitting
A.C. Power adapter with 5 foot cord (Part No. DPGT)
Calibration screwdriver
Storage case
Storage Case For
Gauge and
Accessories
Included
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement