Desa BLP375A Owner's Manual

Add to My manuals
12 Pages

Desa BLP375A is a powerful and efficient propane construction heater that is ideal for heating large spaces. With a heat output of 375,000 Btu/Hr, it can quickly and effectively heat areas up to 11,250 square feet. The BLP375A features a durable steel construction and is equipped with a variety of safety features, including a flame failure safety device and a overheat protection system. It also comes with a convenient carrying handle for easy portability.

advertisement

Desa BLP375A Owner's Manual | Manualzz

PROPANE

CONSTRUCTION

HEATERS

OWNER’S MANUAL

Heater Size: 375,000 Btu/Hr - A Series

Models: BLP375A, RLP375A

IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.

GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUC-

TIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH,

SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE

FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION,

CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE IN-

STRUCTIONS SHOULD USE OR SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS

AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANU-

FACTURER.

375,000 BTU/HR - A SERIES

PROPANE CONSTRUCTION HEATER

SAFETY

INFORMATION

WARNINGS

WARNING: FIRE, BURN, IN-

HALATION, AND EXPLOSION

HAZARD. KEEP SOLID COMBUS-

TIBLES, SUCH AS BUILDING MA-

TERIALS, PAPER OR CARD-

BOARD, A SAFE DISTANCE

AWAY FROM THE HEATER AS

RECOMMENDED BY THE IN-

STRUCTIONS. NEVER USE THE

HEATER IN SPACES WHICH DO

OR MAY CONTAIN VOLATILE OR

AIRBORNE COMBUSTIBLES, OR

PRODUCTS SUCH AS GASO-

LINE, SOLVENTS, PAINT THIN-

NER, DUST PARTICLES OR UN-

KNOWN CHEMICALS.

WARNING: Not for home or recreational vehicle use.

The heater is designed and approved for use as a construction heater under ANSI Z83.7.

The purpose of construction heaters is to provide temporary heating of buildings under construction, alteration or repair. Properly used, the heater provides safe economical heating. Products of combustion are vented into the area being heated.

We cannot foresee every use which may be made of our heaters. Check with your local fire safety authority if you have questions about heater use.

Other standards govern the use of fuel gases and heat producing products for specific uses. Your local authorities can advise you about these.

Carbon Monoxide Poisoning: Some people are more affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced.

Propane Gas: Propane gas is odorless.

An odor-making agent is added to propane gas. The odor helps you detect a propane gas leak. However, the odor added to propane gas can fade. Propane gas may be present even though no odor exists.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

• Install and use heater with care. Follow all local ordinances and codes. In the absence of local ordinances and codes, refer to the Standard for Storage and

Handling of Liquefied Petroleum Gas,

ANSI/NFPA 58 and the Propane Instal-

lation Code, CAN/CGA B149.2. This instructs on the safe storage and handling of propane gases.

• Use only the electrical voltage and frequency specified on model plate. The electrical connections and grounding of the heater shall follow the National

Electric Code, ANSI/NFPA 70 or the

Canadian Electric Code, Part 1.

• Electrical grounding instructions — This appliance is equipped with a three-prong

(grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle or extension cord.

• Approved by the New York City Fire

Department under certificate of Approval #4953. To be used only at construction site with applicable New York

City codes, regulations, rules, directives, permits, etc.

• This product has been approved for use in the Commonwealth of Massachusetts.

• For indoor use only. Provide adequate ventilation.

• Keep heater away from strong drafts, wind, water spray, rain, or dripping water.

• Use only in well-vented areas. Before using heater, provide at least a threesquare-foot opening of fresh, outside air for each 100,000 Btu/Hr of rating. This heater produces carbon monoxide, which is listed by the State of California as a reproductive toxin under Proposition 65.

• Do not use heater outdoors or in occupied dwellings.

• Do not use heater in living or sleeping quarters.

• Keep appliance area clear and free from combustible materials, gasoline, paint thinner, and other flammable vapors and liquids. Dust is combustible. Do not use heater in areas with high dust content.

• Check heater for damage before each use. Do not use a damaged heater.

• Use only propane gas set up for vapor withdrawal.

• Keep propane tank(s) below 100

°

F.

• Do not use heater in a basement or below ground level. Propane gas is heavier than air. If a leak occurs, propane gas will sink to the lowest possible level.

• Use only the hose and factory regulator provided with the heater.

• Check hose before each use of heater.

If highly worn or cut, replace with hose specified by manufacturer before using heater.

• Do not alter heater. Keep heater in its original state.

• Do not use heater if altered.

• Keep heater at least six feet from propane tank(s). Do not point heater at propane tank(s) within 20 feet.

• Minimum heater clearances from combustibles:

Outlet: 8 Ft.

Top: 6 Ft.

Sides: 2 Ft.

Rear: 2 Ft.

• Locate heater on stable and level surface if heater is hot or running.

• Keep children and animals away from heater.

• Turn off propane supply and unplug heater when not in use.

• Never block air inlet (rear) or air outlet

(front) of heater.

• Never move, handle, or service a hot, operating, or plugged-in heater.

• Never attach duct work to front or rear of heater.

• Use only original replacement parts.

This heater must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries.

• Do not adjust regulator below 7 psig or above 20 psig.

100416 2

PRODUCT

IDENTIFICATION

Hot Air Outlet

(Front)

Handle

OWNER’S MANUAL

UNPACKING

1.

Remove all packing items applied to heater for shipment. Keep plastic cover caps (attached to inlet connector and hose/regulator assembly) for storage.

2.

Remove all items from carton.

3.

Check all items for shipping damage.

If heater is damaged, promptly inform dealer where you bought heater.

Fan

Guard

Outer Shell

On/Off Switch

Inlet Connector

BLP& VLP375

Figure 1 - 375,000 Btu/Hr Models

Power Cord

Hose /Regulator

Assembly

LP-PFA/PV 008C

100416 3

375,000 BTU/HR - A SERIES

PROPANE CONSTRUCTION HEATER

THEORY OF OPERATION

The Fuel System: The hose/regulator assembly attaches to the propane gas supply. The propane gas moves through the solenoid valve and out the nozzle.

The Air System: The motor turns the fan.

The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

Clean

Heated

Air Out

(Front)

Combustion

Chamber

DSI

Air For Combustion

Figure 2 - Cross Section Operational View

The Ignition System: The direct spark ignitor (DSI) sends voltage to the ignitor.

The ignitor ignites the fuel and air mixture.

The Safety Control System: This system causes the heater to shut down if the flame goes out. The motor will continue to run, but no heat is produced.

Ignitor

Fan

Motor

Cool Air

In (Back)

Power

Cord

Nozzle

Solenoid

Valve

Air For Heating

Hose/Regulator

Assembly

PROPANE

SUPPLY

Propane gas and propane tank(s) are to be furnished by the user.

Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of

Liquefied Petroleum Gas, ANSI/NFPA 58 and the Propane Installation Code CAN/

CGA B149.2. Your local library or fire department will have these booklets.

The amount of propane gas ready for use from propane tanks varies. Two factors decide this amount:

1.

The amount of propane gas in tank(s)

2.

The temperature of tank(s)

The chart below shows the number of 100pound tanks needed to run this heater.

Do not operate this product with any tank smaller than 100 pounds.

Temperature (

°

F) At Tank

40

°

32

°

20

°

0

°

-10

°

-20

°

Number 3 (Use larger tank below of tanks 40

°

F)

Less gas is vaporized at lower temperatures.

You may need a larger tank in colder weather.

Your local propane gas dealer will help you select the proper supply system. The minimum surrounding air temperature rating for each heater is -20

°

F.

VENTILATION

WARNING: Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.

Provide at least three square feet of fresh, outside air for each 100,000 Btu/Hr of rating. This heater requires a fresh air opening of at least 11.25 square feet. Provide extra fresh air if more heaters are being used.

100416 4

OWNER’S MANUAL

INSTALLATION

WARNING: Review and understand the warnings in the

Safety Information section, page

2. They are needed to safely operate this heater. Follow all local codes when using this heater.

WARNING: Test all gas piping and connections for leaks after installing or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.

Bubbles forming show a leak.

Correct all leaks at once.

4.

Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank will stop gas flow. If this happens, you may hear a click inside the regulator assembly. To reset the excess flow check valve, close propane supply valve and open again slowly.

5.

Adjust regulator between 7 and 20 psig

(see Figure 5). Note: Higher regulator setting will allow heater to produce more heat.

WARNING: Do not adjust regulator below 7 psig or above 20 psig.

Heater may not run properly.

6.

Check all connections for leaks.

7.

Close propane supply valve.

1.

Provide propane supply system (see

Propane Supply, page 4).

2.

Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL fitting counterclockwise into threads on tank. Tighten firmly using a wrench.

IMPORTANT: Tighten regulator with black adjustment knob pointing down.

Pointing adjustment knob down protects regulator from weather damage.

3.

Connect hose to inlet connector.

Tighten firmly using a wrench.

IMPORTANT: Extra hose or piping may be used if needed. Install extra hose or piping between hose/regulator assembly and propane tank. You must use the regulator supplied with the heater.

Hose

Inlet Connector

Figure 4 - Hose and Inlet Connector

E

I

S

N

C

E

A

Supply

Valve

POL Fitting

Hose

5

10

15

20

5

10

15

20

5

10

15

20

Propane

Tank

Regulator Regulator

OPERATION

WARNING: Review and understand the warnings in the

Safety Information section, page

2. They are needed to safely operate this heater. Follow all local codes when using this heater.

TO START HEATER

1.

Follow all installation, ventilation and safety information.

2.

Locate heater on stable and level surface. Make sure strong drafts do not blow into front or rear of heater.

3.

Plug power cord of heater into a threeprong, grounded extension cord. Extension cord must be at least six feet long.

Extension cord must be UL listed.

Extension Cord Size Requirement

Up to 50 feet long, use 18 AWG rated cord.

51 to 100 feet long, use 16 AWG rated cord.

101 to 200 feet long, use 14 AWG rated cord.

4.

Plug extension cord into a 120 volt/60 hertz, three-hole, grounded outlet.

5.

Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank will stop gas flow. If this happens, you may hear a click inside the regulator assembly. To reset the excess flow check valve, close propane supply valve and open again slowly.

6.

Make sure regulator is set between 7 and 20 psig. Note: Higher regulator setting will allow heater to produce more heat.

Adjustment

Knob

(pointing down)

Figure 3 - Regulator With Adjustment

Knob Pointing Down

Figure 5 - Adjustable Regulator Set At

7 psig

WARNING: Do not adjust regulator below 7 psig or above 20 psig.

Heater may not run properly.

7.

Turn on/off switch to the ON position.

Note: If heater does not start, turn on/ off switch to the OFF position. Wait ten seconds for safety control to reset, then try again.

Continued

100416 5

375,000 BTU/HR - A SERIES

PROPANE CONSTRUCTION HEATER

OPERATION

Continued

TO STOP HEATER

1.

Tightly close propane supply valve on propane tank(s).

2.

Wait a few seconds. Heater will burn gas left in supply hoses.

3.

Turn on/off switch to the OFF position.

4.

Unplug heater.

TO RESTART HEATER

If safety control stops gas flow to heater, motor will continue to run.

To restart heater:

1.

Turn on/off switch to the OFF position.

2.

Wait ten seconds, then turn on/off switch to the ON position.

If heater does not restart

• Check manual valves (if any) and supply valves (on propane tank). Make sure they are open.

• Check fuel level in propane tank(s). If fuel level is too low, contact local propane gas company.

If heater still does not restart, contact your local service center.

STORAGE MAINTENANCE

CAUTION: Disconnect heater from propane supply tank(s).

1.

Store propane tank(s) in safe manner.

See Chapter 5 of Standard for Storage and Handling of Liquefied Petroleum

Gases, ANSI/NFPA 58 and the Propane

Installation Code CAN/CGA B149.2.

Follow all local codes.

2.

Place plastic cover caps over brass fittings on inlet connector and hose/regulator assembly.

3.

Store in dry, clean, and safe place. Do not store hose/regulator assembly inside heater combustion chamber.

4.

When taking heater out of storage, always check inside of heater. Insects and small animals may place foreign objects in heater. Keep inside of heater free from combustible and foreign objects.

WARNING: Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur.

1.

Keep heater clean. Clean heater annually or as needed to remove dust and debris. If heater is dirty or dusty, clean heater with a damp cloth.

2.

Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections.

Bubbles forming show a leak. Correct all leaks at once.

3.

Inspect hose/regulator assembly before each use. If hose is highly worn or cut, replace.

4.

Have heater inspected yearly by a qualified service agency.

5.

Keep inside of heater free from combustible and foreign objects.

6 100416

OWNER’S MANUAL

SERVICE

PROCEDURE

WARNING: Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur.

CLEANING FAN

Clean fan every 500 hours of operation or as needed.

1.

Remove screws on side cover using

5/16" nut-driver.

2.

Remove side cover.

3.

Detach the five motor wires from parts under heater shell. Be sure to detach only wires coming from motor.

The five motor wires are:

• white wire—to terminal board

• black wire—to terminal board

• blue wire—to thermal switch wire

• orange wire—to solenoid valve

• green wire—to grounding screw on shell

4.

Remove fan guard from rear of heater.

Thermal

Switch Wire

Grounding Screw

Terminal

Board

5.

Reach into rear of heater shell. Carefully pull motor wires through hole in bottom of shell. Note: Pull wires through hole one at a time.

6.

Remove nuts and mounting bolts holding motor mount to shell. Use 3/8" nutdriver and 7/16" wrench.

7.

Carefully pull motor and fan out of shell. IMPORTANT: Be careful not to damage fan. Do not set motor and fan down with the weight resting on fan.

This could damage fan pitch.

8.

Turn motor and fan around. Place motor and fan into shell backwards. Note: Motor will go into shell first (see Figure 8).

9.

Line up rear mounting holes in shell with first hole on each side of motor mount (see Figure 8). Note: When holes are lined up, fan should be outside of shell.

10. Holding mounting bolt, carefully reach through fan blades into rear of heater.

Be careful not to damage fan pitch. Insert bolt through motor mount and shell.

With free hand, attach nut finger tight.

Repeat process for other mounting hole.

11. Use 1/8" hex wrench to loosen setscrew which holds fan to motor shaft (see Figure 9).

Rear

Mounting

Hole

First

Hole

12. Slip fan off motor shaft.

13. Clean fan using soft cloth moistened with kerosene or solvent.

14. Dry fan thoroughly.

15. Replace fan on motor shaft. Make sure setscrew is touching back of flat surface on motor shaft (see Figure 10).

16. Place setscrew on flat of shaft. Tighten setscrew firmly (40-50 inch-pounds).

17. Remove two nuts and bolts securing motor mount to shell.

18. Pull motor and fan from shell. Turn motor and fan around. Carefully place back in shell. Note: Fan will go into shell first.

19. Line up mounting holes in shell with holes on motor mount. Replace four bolts through shell and motor mount.

Insert bolts from outside of heater.

Tighten nuts firmly.

20. Route motor wires through hole in bottom of shell (see Figure 7).

21. Connect motor wires as follows (see

Figure 6):

• white wire—to terminal board.

Note: Attach to empty connector on white wire side of terminal board.

• black wire—to terminal board.

Note: Attach to empty connector on black wire side of terminal board.

• blue wire—to thermal switch wire

• orange wire—to solenoid valve

• green wire—to grounding screw on shell

22. Replace side cover.

23. Replace fan guard.

Solenoid Valve

Figure 6 - Location of Motor Wires

026

Figure 8 - Fan and Motor Turned Around

Fan

Setscrew

Fan

Hub

Motor

Shaft

Setscrew

LP-P ON

Figure 10 - Fan Cross Section

Mounting

Bolts

Motor

Wires

Motor

Mount

Figure 7 - Location of Fan and Motor

100416

Location

Motor shaft

7

375,000 BTU/HR - A SERIES

PROPANE CONSTRUCTION HEATER

WIRING DIAGRAMS

Ignitor

Orange

Blue

White

Solenoid

Valve

Orange

Green

DSI

Control

Black

Blue

Connector

Green

Blue

T

Thermal

Switch

Blue Blue

Connector

Motor

White

Green

Power

Cord

White

Black

Black Black

Terminal

Board

On/Off

Switch

Figure 11 - Wiring Diagram

Black

Ignitor

Black

Orange

Solenoid

Valve

Blue

Green

Direct Spark

Ignitor

Blue

Thermal Switch

Blue

Orange

White

White

Black

Centrifugal

Switch

Green

Motor

Green

Ground Line

Figure 12 - Electrical Ladder Diagram

White

Neutral

8 100416

OWNER’S MANUAL

SPECIFICATIONS REPLACEMENT

PARTS

Output Rating (Btu/Hr)

Fuel

Fuel Consumption

Gallons/Hour

Pounds/Hour

Supply Pressure To Regulator

Minimum (for purposes of

input adjustment)

Maximum

Regulator Outlet Pressure

Hot Air Output (CFM)

Motor

Electric Input

Amperage

Ignition

Weight (Pounds)

Heater

Shipping

Size - L x W x H (Inches)

225,000 to 375,000

Propane Vapor Only

2.5 Minimum/4.0 Maximum

10.4 Minimum/17.4 Maximum

25 psig

Tank Pressure

7-20 psig

1500

1725 RPM, 1/5 HP

120 V/60 Hz

4.2

Direct Spark

42

49

34 x 13 x 19.5

ACCESSORIES

Purchase accessories and parts from your nearest dealer or service center. If your dealer or service center can not supply an accessory or part, either contact your nearest Parts Central (listed in the separate Authorized Service Center booklet) or call

DESA International’s Parts Department at

1-800-972-7879 for referral information.

You can also write to the address listed on the back page of this manual.

Hose: LPA1020

A 10 foot hose for locating heater further away from propane tank(s).

Regulator: LPA2020

Hose and Regulator Assembly:

LPA3030

Fuel Gas Connector: LPA4020

A POL adapter with excess-flow check valve.

Thermostat: HA1210

TECHNICAL

SERVICE

You may have further questions about this heater. If so, contact DESA

International’s Technical Service Department at 1-800-323-5190.

You can also visit DESA International’s

Technical Service web site at www.desatech.com.

SERVICE

PUBLICATIONS

You can receive an Illustrated Parts List free of charge. Send your request and a selfaddressed, stamped envelope to DESA International (address on back page). Be sure to include the heater model number. You can purchase a service manual for $5. Make check payable to DESA International.

WARNING: Use only original replacement parts. This heater must use design-specific parts.

Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries. This will also protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they cannot supply original replacement part(s), either contact your nearest Parts Central or call DESA

International’s Technical Service Department at 1-800-323-5190. When calling

DESA International, have ready:

• your name

• your address

• model and serial numbers of your heater

• how heater was malfunctioning

• purchase date

In most cases, we will ask you to return the defective part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product.

If they cannot supply original replacement part(s), either contact your nearest Parts

Central or call DESA International’s Parts

Department at 1-800-972-7879 for referral information. When calling DESA International, have ready:

• model number of your heater

• the replacement part number

100416 9

375,000 BTU/HR - A SERIES

PROPANE CONSTRUCTION HEATER

ILLUSTRATED

PARTS

BREAKDOWN

BLP375A

RLP375A

2

21

5

6

1

27

4

18

3

10

24

19

23

16

25

15

20

Note: Screws are standard hardware items

14

7

26

13

28

12

17

8

9

22

11

10 100416

OWNER’S MANUAL

PARTS LIST

BLP375A

RLP375A

21

22

23

24

25

26

27

28

14

15

16

17

18

19

20

8

9

10

11

12

13

6

7

4

5

2

3

KEY

NO.

1

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 9 of this manual.

PART

NUMBER

100409-01

100409-06

097847-01

097849-01

097805-01

097918-01

097917-01

097806-02

097811-01

097802-01

M50104-02

097964-01AA

M11143-1

099896-05

097809-01

097828-01

098201-01

100145-01

099679-01

M51605-02

097965-01AA

101732-03

097829-02

098226-01

098827-01

099125-01

097966-09AA

097848-01

100146-01

LPA3030

100407-01

097815-05

097941-09

097895-05

097916-01

LPA1020

LPA2020

LPA4020

HA1210

DESCRIPTION

Outer Shell Assembly (BLP375A)

Outer Shell Assembly (RLP375A)

Combustion Chamber Assembly

Burner Assembly

Ignitor

Cleat

Handle

Ignitor Cable

Fan

Motor

Shorty Bushing

Fan Guard

Strain Relief Bushing

Cord Assembly

Male Fitting

Solenoid Bracket

Solenoid Valve

Fuel Tube

Nozzle

D.S.I. Control

Side Cover

Thermal Switch Kit

Motor Mount

On/Off Switch

Compression Fitting

Terminal Board

Base

Rear Plate Assembly

Elbow Fitting

PARTS AVAILABLE - NOT SHOWN

Regulator & Hose Assembly

Electrical Decal

General Information Decal

Tradename Decal (RLP375A)

Tradename Decal (BLP375A)

Baffle

Hose

Regulator

Fuel Gas Connector

Thermostat

1

1

1

1

2

1

1

1

1

1

QTY.

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

1

1

1

1

100416 11

WARRANTY AND REPAIR SERVICE

KEEP THIS WARRANTY

LIMITED WARRANTY

DESA International warrants this product and any parts thereof, to be free from defects in materials and workmanship for one (1) year from the date of first purchase when operated and maintained in accordance with instructions. This warranty is extended only to the original retail purchaser, when proof of purchase is provided.

This warranty covers only the cost of parts and labor required to restore the product to proper operating condition. Transportation and incidental costs associated with warranty repairs are not reimbursable under this warranty.

Warranty service is available only through authorized dealers and service centers.

This warranty does not cover defects resulting from misuse, abuse, negligence, accidents, lack of proper maintenance, normal wear, alteration, modification, tampering, contaminated fuels, repair using improper parts, or repair by anyone other than an authorized dealer or service center. Routine maintenance is the responsibility of the owner.

This Express Warranty Is Given In Lieu Of Any Other Warranty Either Expressed Or Implied, Including Warranties Of Merchantability

And Fitness For A Particular Purpose.

DESA International assumes no responsibility for indirect, incidental or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations or exclusions may not apply to you. This Limited Warranty gives you specific legal rights and you may also have other rights which vary from state to state.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

WARRANTY SERVICE

Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA International will repair or replace the heater without charge.

REPAIR SERVICE

Return your heater to your nearest authorized service center. Repairs not covered by the warranty will be billed at standard prices. Each Service

Center is independently owned and operated. We reserve the right to amend these specifications at any time without notice.

Model

Serial No.

Date of Purchase

INTERNATIONAL

2701 Industrial Drive

P.O. Box 90004

Bowling Green, KY 42102-9004 www.desatech.com

For information, write: DESA International, P.O. Box 90004

Bowling Green, Kentucky 42102-9004 ATTN: Customer Service Department

When writing, always include model number and serial number.

100416 01

NOT A UPC

100416-01

Rev. H

03/00

advertisement

Key Features

  • 375,000 BTU/Hr heat output
  • Heats up to 11,250 square feet
  • Durable steel construction
  • Flame failure safety device
  • Overheat protection system
  • Convenient carrying handle

Related manuals

Frequently Answers and Questions

What is the heat output of the Desa BLP375A?
375,000 Btu/Hr
What is the maximum heating area of the Desa BLP375A?
11,250 square feet
What safety features are included on the Desa BLP375A?
Flame failure safety device and overheat protection system
Does the Desa BLP375A have a carrying handle?
Yes
Download PDF

advertisement