Intruder UK Product Catalogue - Issue 15.30

Intruder UK Product Catalogue - Issue 15.30
Intruder
Catalogue
UK Intruder Catalogue
Introduction
Introduction of Intruder Alarm to EN Standards/
PD6662:2010
Contents
11/13
1
UK Intruder Catalogue
Introduction
Welcome to the latest edition of the Tyco Safety Product’s UK Intruder Catalogue of products available from our
distribution centre in Letchworth. We aim to make your product range as comprehensive as possible to ensure you
never need go anywhere else. To meet this goal, our product specialists, with your help, have selected the most
appropriate, cost effective product range available on the market.
In line with our ISO 9000 accreditation, only those products that meet the highest quality criteria have been included.
Our goal is to despatch product on the same day as we receive your order. Our warranty and service returns policy is
second to none. We recognise that your business is highly dependent on excellence in customer service and to help
achieve this we offer extended warranty from many of our suppliers. Full credit is also available
on a “No Question – No Fuss” basis for any new
in-warranty product returned to the distribution
centre. Our standard duration for warranty is a
minimum of 12 months credit.
We are positive that together we can help grow
your business and we look forward to working
with you in the future.
Tyco Safety Product’s Web site contains an endless supply of product related information available in multiple
languages - English, French, German, Spanish, Italian, Dutch and Polish. It is regularly updated and features many
aids to the selling process including presentation material, independent product test results and detailed technical
information.
Our web site can be found at www.tycoemea.com
NEW - We have posted all of the ADT/Tyco datasheets on the website.
To enhance customer specifications and quotations we also provide a series
of product datasheets which can give our clients an opportunity to read
more about the product. We are positive that together we can help grow
your business and we look forward to working with you in the future
11/13
2
Uk Intruder Catalogue
Introduction of Intruder Alarm to European Standards
IMPLEMENTATION OF PD 6662:2010
PD6662:2010 and the new editions of the European Standards took place on the 1st June 2012 as previously
advised. This mean that from 1st June 2012 onwards all new intruder and hold-up alarm systems (I&HASs) must meet
these standards.
The Association of Chief Police Officers (ACPO) of England, Wales and Northern Ireland have agreed that (I&HASs)
installed to PD 6662:2010 can obtain Unique Reference Numbers (URNs) up until 1st October 2012.
What is PD 6662:2010
PD 6662:2010 is a version of the PD 6662:2004 document to which British alarm installers have been working.
There has been a dual running of the two standards since 31st May 2010, and fro the 1st June 2012 only PD
6662:2010 can be used. The documents which are incorporated into the British PD 6662:2010 scheme are:
// EN50131-1:2006+A1:2009 (General Requirements)
//
//
//
//
//
//
EN50131-3:2009 (Control and Indicating Equipment)
EN50131-6:2008 (Power Supplies)
DD CLC/TS 50131-7:2008 (Installation Guidelines)
EN50131-8:2009 (Fog device systems)
BS8243:2010 (Configuration for Confirmed Alarms)
DD263:2010 (Maintenance and Remote Support)
CONFIRMATION OF HOLD-UP (PERSONAL ATTACK ALARMS)
Confirmation of hold-up (personal attack) alarms is not required initially for new I&HASs. However, confirmation is
required under ACPO policy response is lost due to so many false hold-up alarms.
When confirmation of hold up alarms is included in an I&HASs, the hold up provisions of BS8242:2010 must be
followed. This is covered in the scope of BS 8243:2010, which states that if hold-up confirmation is to be included in
the installation, then the relevant clauses of BS 8243:2010 apply.
There are four recognised methods of hold-up alarm confirmation as follows:
Audio confirmation
Visual confirmation
Sequential confirmation
Telephone confirmation (call -back)
Some further information is given below.
To explain sequential confirmation of hold-up in simple terms the first hold-up device to activate causes an unconfirmed
hold-up alarm signal to be transmitted to the ARC and a confirmation timer to start. If a second hold-up device is
activated within the confirmation time (typically up to 8 hours, but can be up to 20 hours depending on how the control
equipment is set up) then a sequentially confirmed hold-up alarm signal is transmitted to the ARC and the police are
called.
If a second independent hold-up device does not activate within the confirmation time a sequentially confirmed hold-up
alarm is not generated and the police are not called.
11/13
3
Uk Intruder Catalogue
Introduction of Intruder Alarm to European Standards
Something very similar to this can be achieved with a multi- action hold-up device. Such devices are new to the market
and you should ensure that your customers understand how they are operated, and that they are comfortable about the
way they are operated, before they agree to have them installed.
The ARC needs to be able to differentiate between sequentially confirmed hold-up alarms and sequentially confirmed
intruder alarms. Please check with your ARC that they can handle sequentially confirmed hold-up alarms before you
proceed with installations that include sequential confirmation of hold-up,
Telephone confirmation involves the ARC calling the supervised premises to confirm whether hold-up is taking place.
ACPO have advised that there have been a number of cases where the nominated telephone number for calling back
has been inappropriate in the sense that the telephone call has not gone through to a relevant location and the police
have attended a false hold-up alarm. Please ensure that telephone numbers are for relevant locations.
TAMPER DETECTION OF ANCILLARY CONTROL EQUIPMENT (ACE)
Tables 12 and 13 of BS EN 50131-1:2006, as amended in 2009 (system requirements), call for tamper detection
of ancillary control (ACE) . This is in the form of detection of opening by normal means (in all Grades) and detection of
removal from mounting (in Grades 3 and 4 (also Grade 2 if wire-fee). BS EN 501321-1 does not make any distinction
between ACE that is sealed (for example potted) and ACE that is nor sealed.
On the other hand, Clause 8.7 of BS EN 50131-3:2009 (control and indicating equipment.) categorises ACE as follows:
Type A: Access to internal elements resulting from damage to the housing could not enable the status of any part of the
I&HAS to be changed or to prevent the initiation of mandatory notification (EXAMPLE: potted device).
Type B: Access to internal elements resulting from damage to the housing could not enable the status of any part of
the I&HAS to be changed or to prevent the initiation of mandatory notification (EXAMPLE: ACE (includes
connections for detectors).
BS EN 50131-3 does not require ACE categorises as Type A to include tamper detection of opening by normal means
and it appears (although the matter is not entirely clear in BS EN 50131-3) that ACE categorised as Type A may not
need to include tamper detection of opening by normal means and does not need to include tamper detection of
removal from mounting.
The wording that has been agreed at BSI is as follows
“GW/1/1 noted that both CENELEC TC79 working groups (WG1 and WG3) were likely to make
changes to harmonise the current discrepancy in the tamper detection requirements given
by EN 50131-1 and EN 50131-3 for ACE classified as type A. It was agreed that, pending this
harmonisation, it would be inappropriate to impose requirements in the UK that might penalise
manufacturers or installers. It was therefore agreed that, until further notice, requirements given in
EN 50131-1 clause 8.7.2 (including Tables12 and 13) should be optional for ACE defined as Type
A by EN 50131-3 clause 8.7. The effect of this would be that detection of tamper of such devices
through opening by normal means or by removal from mounting is not necessary.”
Note: CENELEC is the European Committee for Electrotechnical Standardisation and TC79 is the CENELEC Technical
Committee for standards for alarm systems. WG1 and WG3 are working groups of TC79.
11/13
4
Uk Intruder Catalogue
Introduction of Intruder Alarm to European Standards
INDICATORS ON MOVEMENT DETECTORS
Table 9 of BS EN 50131-1:2006, as amended in 2009, shows that indications of set and unset are not permitted in
Grades 3 and 4. The applies to Control and Indicating Equipment (CIE) and Ancillary Control Equipment (ACE).
There is a requirement in Clause 8.3.12 of BS EN 50131-1 for a user, at access level 2, to be able to carry out a
functional test of intrusion detectors and hold up device(s), provided such tests are non destructive. For movement
detectors this means being able to walk test the detectors. This applies in all Grades.
There is a recommendation in H.3 of Annex H of DD CLC/TS 50131-7:2008 (and 2010) that walk test indication
should only operate during maintenance or test procedures. This appears to be relevent to all Grades.
For Information, Clause 4.2.2 of BS EN 50131-2-2:2008 (passive infrared movement detectors) states:
4.2.2 Indication of detection
An Indicator shall be provided at the detector to indicate when an intrusion signal or message has been
generated. At grades 1 and 2 this indicator shall be capable of being enabled and disabled either
remotely at Access level 2 and /or locally after removal of cover which provides tamper detection as
described in Tables 1 and 4 this indicator shall be capable of being enabled and disabled remotely at
Access Level 2.
The enabling/disabling remotely at Access Level 2 (which is mandatory for movement detectors in Grades 3 and 4)
means that the customer (end user) will have the capability of turning the indicators on or off. However, having the
capability of turning the indicators off is not the same thing as being required to do it.
There are circumstances in which having the movement detector indications turned on can lead to a security risk. A
good example is where indications are shown in the inset condition and where members of the public may have access
to the unset area. It may be possible in such circumstances to determine the area of coverage of movement detectors,
which might assist in the planning of a subsequent break-in.
11/13
5
Uk Intruder Catalogue
Contents
Section
Accessories
Audio Verification
Batteries
Contacts
Day Alarms
Detectors
External Lighting Control
Visonic Control Panels
Galaxy Control Panels
Life Safety Units
Power Supply Units
Radio Equipment
Signalling
Sounders
11/13
6
Accessories
This chapter contains information about our range of Accessories
Introduction
Exit Terminators
HUA’s
Door Loops
Junction Boxes
Filters and Relays
Locks
Service Tools
Cables
03/16
1
Accessories
Introduction
A wide range of general use devices, for the installation and
servicing of security systems. These include such items as
junction boxes, test equipment and relays that can be used
in a variety of ways.
03/16
HUA’s are available in various finishes and designs
which meet with the latest BS8243 requirements
and fully comply with ‘The ACPO 10 Point Plan’ and all
requirements under EN50131-1:2006 +A1:2009 and
PD6662:2010 A1 + A2.
2
Accessories
Termination Switches
Exit Terminators
Features:
Easy Fit
Unobtrusive Designs
Sleek Designs
Exit terminate buttons are used to provide a final set input
to alarm systems. Generally sited outside the premises,
operation of the exit terminate button is the final action
required in the setting process.
This facility is mandatory in some police authority areas.
Order Codes:
1147
1148
609.002.024
DRB002NF
03/16
Surface mount exit terminate
button, Smith type
Surface mount box for use with
1147 exit terminate button
Elmdene set switch with white
clip on bezel
ICS S/S Intruder set switch
3
Accessories
HUA’s
Static CQR HUA’s
Features:
A range of static HUA’s from CQR that conform to Grade
3 of EN50131-1. The new range has the benefit of
having separate tamper and alarm contacts, which are
necessary for reporting for Grade 3 systems, the tamper
being a spring micro switch and the alarm contacts being
a magnetic/reed switch.
All units are Grade 3 Double Push with integral resistors
for use with most control panels or option for Double Pole.
Spare terminals allow through connection for multiple
units wired to one zone.
HUA’s comply with ‘The ACPO 10 Point Plan’ and
all requirements under EN50131-1:2006 and
PD6662:2004 A1 + A2.
No screw to secure front cover
Original key to reset
Tactile flush activation buttons
Improved case / back-plate
Improved access for cable entry
No requirement to remove PCB when wiring
Access for power tools when mounting
Secure spring mechanism
Technical Specifications:
DP3 Grade 3
Double Push Hold Up Device
Case Material:
ABS or ABS /304 Grade
Stainless Steel
Buttons:
Acetal
Reset Key:
Steel
Dimensions mm:
75 mm x 62 mm x 29.5 mm
Operation:
2 button, latching / no latching
Reset Method:
Key
Switch Rating:
3 A 125 VAC changeover
Anti Tamper:
Normally closed tactile 24 v DC
at 1 A max
Standards:
EN50131-1:2006 + A1:2009
Grade 3
Environmental Class:
II
Order Codes:
PADP3-SS-BK
PADP3-WH-M
PADP3L-BS-BK
KEYPAM
1183
1184
03/16
DP3 Double push PAB S/S
multi G3
DP3 Double push PAB WH
multi G3
DP3 Double push PAB Brass
multi g3
Spare metal key for all DP3
range
Replacement key for Knight
Plastics HUA
Replacement key for Maximal
HUA
4
Accessories
HUA’s
4 Button HUA
Features:
The 4 button PA is an electronic PA device with two totally
independent pairs of twin push PA buttons. The buttons
are arranged on opposing faces, to ensure that the
operation method of each pair is completely different and
independent.
The four buttons are grouped into two pairs – the top
buttons and the side buttons. Activation of each pair of
buttons is signalled back to the CIE via separate relay
outputs (Output A and Output B). The connection to the
CIE may be via conventional wiring (often referred to as 4
wire) or via End of Line (Double EOL). Jumpers are
provided on the board to allow the installer to select the
EOL and the Alarm bypass resistor. This feature is provided
separately for both outputs.
03/16
LEDs to Indicate Status
Lid and Back tampers
Selectable Confirmation Mode
Key Reset
Integral Timer
Dimensions : 84mm x 65mm x 26 mm
Environmental Class: 2
Selectable Latching/Non-Latching
Technical Specifications:
Supply volts (normal operation)
10.5 – 15V
Supply volts (limits)
7.5 – 15V
Supply current (nominal)
20mA
Confirmation time
12 hrs
Min Output relay operate time
0.9s
Order Code:
PA4S
KNI 4 Button Confirmable PAB
Stainless Steel Cover
5
Accessories
Door Loops
Door Loops
Features:
Compact
Various Sizes
Choice of colour
These are used for looping from door frame to a door.
For use with contacted locks, wired and covered doors etc.
Order Codes:
EDL1
EDL2
EDL3
EDL3-BN
EDL1-KIT
EDL2-KIT
EDL3-KIT
EDL2-BN-KIT
EDL3-BN-KIT
03/16
30 cm fixed length door loop
white
25 cm white door loop
extendable up to 170 cm
50 cm white door loop
extendable up to 330 cm
50 cm Brown door loop
extendable up to 330cm
30 cm fixed length door loop
white Inc 2 EN3-JB9-HD-W &
2 Grommets
25 cm white door loop
extendable up to 170 cm Inc 2
EN3-JB9-HD-W & 2 Grommets
50 cm white door loop
extendable up to 330 cm Inc 2
EN3-JB9-HD-W & 2 Grommets
25 cm Brown door loop
extendable up to 170 cm Inc 2
EN3-JB9-HD-W & 2 Grommets
50 cm Brown door loop
extendable up to 330 cm Inc 2
EN3-JB9-HD-W & 2 Grommets
6
Accessories
Junction Boxes
Junction Boxes
Features:
Real tamper switch with spring
operation
Clamp style terminals
Choice of models
EN Grade 3 compliant
Designed for use in security applications, these junction
boxes are provided with a tamper connection which will
open circuit whenever the lid is removed.
Order Codes:
EN3-JB10
EN3-JB10-BN
EN3-JB9-HD
EN3-JB9-HD-BN
EN3-JB26
EN3-JB9-HD-Grommet
03/16
Elmdene 10 way Grade 3
White JB with Tamper - 8 way
plus 2 terminals for Tamper
Elmdene 10 way Grade 3
brown JB with tamper - 8 way
plus 2 terminals for Tamper
Elmdene 9 way HD Grade 3
white JB with Tamper and
Sealing Gasket - 7 way plus 2
terminals for tamper with
environmental class 3 sealing
gasket
Elmdene 9 way grade 3 brown
JB with tamper with sealing
gasket. 7way plus 2 terminals
for tamper with environment
class 3 sealing gasket
Elmdene 24 way Grade 3
white JB with Tamper - 24 way
plus 2 terminals for Tamper
Pack of 10 End Grommets for
HD JD’s
7
Accessories
Relays and Filters
Mains Filtering
Description
Order Codes
ACT1313 12Vd.c. Spike Supressor
Induced AC (Electromagnetic Interference) is caused when Intruder
cables come near mains or telephone wires. High induced AC voltage
causes random and intermittent false alarms as well as system
malfunctions. The suppressor connects directly across the DC supply and
to mains earth, dumping induced AC noise and clamping the DC voltage
against ‘spikes’.
3127
Focus Mains Filter
This unit combines both transient protection and filter protection. The
unit is designed to be hard-wired into the mains terminal block across
neutral and earth. To obtain the best performance from the device, the
leads should be kept as short as possible.
ACT-2323
ACT 2468 Radio frequency filter.
The ACT 2468 is a powerful 1 Amp rated RFI filter specifically designed
for use on any DC troublesome alarm circuit cable. They are particularly
beneficial where data corruption occurs to keypads and LIM’s (especially
on take-overs).
3141
Relays
6504
Hoyles S312N double pole interface relay. This device accepts a variety
of input conditions (Voltage, Logic, Closed Circuit and Open Circuit) for
interfacing various signals via voltage free DPCO contacts.
609.001.214
Hoyles S312T double pole interface relay. This device accepts a variety
of input conditions (Voltage, Logic, Closed Circuit and Open Circuit) for
interfacing various signals via voltage DPCO contacts.
6698
Hoyles S320 interface relay . This device accepts a variety of input
conditions for interfacing various signals (Voltage, Logic, Closed Circuit
and Open Circuit). Output via voltage free SPCO contacts. With a self
adhesive back for easy mounting.
609.001.215
Elmdene Multipurpose Relay. MPR001 MULTI-PURPOSE RELAY
Supply 12-13.8Vdc Current 20mA Trigger Input 1.5mA Switch Load
Maximum [email protected] 24V dc or 0.5A @ 125V ac
03/16
8
Accessories
Locks
Contacted Locks
Description
Order Codes
Chubb 3G110 5 Detainer Mortice Deadlock.
The Chubb 5 Detainer 3G110 Deadlock is supplied with micro-switches
for use with alarm system. Has a 5 Detainer mechanism. It is supplied
with a total of 2 keys. Case is a silver finish and the forend is either brass
or satin chrome finish
.
4001-ICS
4049-ICS
Chubb 3G114 5 Lever Mortice Deadlock
The Chubb 5 Lever 3G114 Deadlock is locked or unlocked by key from
either side. Chubb 3g114 deadlock, is supplied with microswitches for
use with alarm systems. This deadlock comes Supplied with matching
escutcheons. This lock has a 5 lever mechanism. It is supplied with a total
of 2 keys. Case comes in a silver finish and forend comes in either brass or
satin chrome finish.
A diecast metal box measuring 90H x 38W x 30D mm containing a
keyswitch and anti-tamper switch. Brown. Boxed Outside Shunt D.C.
4015
Document Box
Description
Order Codes
Metal Document Box for fitting adjacent to control panels to keep
system information secure.
9313
9314
(Key)
03/16
9
Accessories
Service
Service Tools
Description
Order Codes
Minitran 452 Test Telephone Handset
The Minitran 452 is a new low cost Telephone Test Set designed to
enable alarm technicians to test lines and verify signals sent to the Alarm
Receiving Centre during commissioning and maintenance inspections.
M0452-00
ACT 6/12V Intelligent Battery Tester
The ACT/612 is a dual voltage intelligent battery tester, designed for 6V
and 12V lead acid batteries from 1.2Ah to 100Ah, making it capable
of testing 12V batteries up to 150Ah. It’s the only product of its kind to
have an Ampere-hour (Ah) calibration control, enabling Ah readings to
be adjusted to suit various battery technologies including standby SLA
(AGM), cyclic GEL and car FLOODED (WET) batteries.
ACT-612- IBT
ACT-6000 ACT Autoranging Digital Meter
The NEW ACT-6000 from ACT Meters provides a high resolution 4000
count digital display and offers a range of measurement modes for AC
and DC applications, resistance and current measurement.
ACT-6000
9082
ACT 418 Professional Test Leads
Professional test leads to suit any multimeter. Leads are constructed of
highly flexible silicone cable terminating at one end with retractable 4mm
plugs and fully insulated probes with attachable ‘Crock-Clips’ at the other.
Overall length 1.2metres, supplied one red, one black.
03/16
10
Accessories
Cable
Cable
Product Code
Cable
355004-WHT-100
Webro 4c Security White PVC
100 m
355006-WHT-100
Webro 6c Security White PVC
100 m
355012-WHT-100
Webro 12c Security White PVC
100 m
355006-BRN-100
Webro 6c Security Brown PVC
100 m
355008-BRN-100
Webro 8c Security Brown PVC
100 m
355012-BRN-100
Webro 12c Security Brown PVC
100 m
355008LSF-WHT100
Webro 8c Security LSF White 100m
100 m
320018-WHT-100
Webro 3183Y 1.0mm mains flex White
100 m
428723-WHT-100
Webro 8723 EQ White LSF
100 m
428723-WHT-500
Webro 8723 EQ White LSF
500 m
355106LSF-WHT100
Webro 6c Security Screened White LSF
100 m
520003-WHT-100
Webro 3pr CW1308 PVC White
100 m
355001-WHT-250
Webro Hard Drawn Lacing Wire
250 m
355020-WHT-100
Webro 20c Security White PVC
100 m
355030-WHT-100
Webro 30c Security White PVC
100 m
110401-WHT-UV-100
Cat 5e UTP UV WHITE PVC
100 m
428723UG-100
Beldon style 8723 UG
100 m
03/16
Reel Size
11
Batteries
This chapter contains information about our range of Batteries
Introduction
VRLA Re-chargable
Small Disposable
10/16
1
Batteries
Introduction
VRLA
We supply a wide range of Powersonic, Valve
Regulated Lead Acid (VRLA) batteries for the
support and back up of Intruder, Fire and Access
control systems. We hold an extensive stock of the
PS range (standby / float charge application) these
include all key models as displayed in our product
summary sheet.
Power-Sonic’s longstanding ISO9001 certificate
just shows their commitment to quality and
improvement over the years.
Primary Alkaline batteries
Most of the RF devices we use, utilise primary
alkaline batteries. Each of these devices depends on
a high quality powerful energy source for optimum
performance. For all these device types, we offer
a complete power one Alkaline range with AA/
AAA and 9V-Block type. Outstanding performance,
where long run time, safety and reliability are a
requirement.
Primary Lithium Cylindrical Cells
High Capacity, High Energy,for long lasting energy
In a addition we also supply a range of small
supply in Lithium-Manganese Technology
disposable/rechargeable batteries, for the associated
peripherals that go with the Intruder RF product
Some home security sensors and sensor networks
range.
require a highly reliable energy source for optimum
performance. For all of these applications we offer
Rechargeable NiMH Cylindrical Cells
a range of Lithium primary Round cells and Battery
packs. Giving superior shelf and operating life for
Outstanding performance and product support
communication and wireless sensor applications.
worldwide is available for the design engineer:
Focused on the requirements of power demanding
modern electronic devices, we offer a complete
range of high-tech Rechargeable NiMH Cylindrical
Cells and Batteries:
Primary Lithium button cell batteries
Nearly all of the Control panels need safe and
reliable Memory Back Up (MBU) or Real Time Clock
(RTC) batteries. But also for long-term applications
such as remote controls where long running time, a
slim design and low weight for
a battery are important.
10/16
2
Batteries
Re-Chargeable
VRLA Re-Chargeable
Product Code
PS-1212
PS-1221
PS-1230
PS-1242
PS-1270
PS-12120
PS-12170
PS-12260
PS-122380
PS-12650
PS-6100
10/16
Voltage
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
6V
Autonomy
1.2Ah
2.1Ah
3.0Ah
4.2Ah
7.2Ah
12.0Ah
17.0Ah
26.0Ah
38.0Ah
65.0Ah
10.0Ah
Dimensions
97 x 42 x 54mm
178 x 34 x 66mm
134 x 67 x 66mm
90 x 70 x 101mm
151 x 65 x 98mm
151 x 98 x 100mm
181 x 76 x 167mm
167 x 175 x 125mm
197 x 165 x 170mm
348 x 167 x 178mm
151 x 51 x 98mm
Weight (kg)
0.55
1.0
1.2
1.7
2.6
4.1
6.1
9.4
13.8
24.0
2.1
3
Batteries
Small Disposable
Small Disposable Batteries
Product Code
TY-4103-F2
TY-4106-F2
TY-4122-F1
TYCR123PE1FE
TY-GP910A-BL2
TY-CR2025-BL5
TY-LS14500-BL1
TYU9VLJPBP
9-103091
L91
CS0388
DOM-BAT-CRI
LBP001
7K67J
CR2450-BL1
LSH20
GP85AAAHC
DL1-3N
BR1225-BN-BL1
SL750-S-BL1
10/16
Battery
Varta Alkaline (1.5 V/1350 mAh) Battery: Size AAA
Varta Alkaline (1.5 V/3200 mAh) Battery: Size AA
Varta Alkaline (9 V/600 mAh) Battery: Size E
Panasonic 3 v Lithium CR123A in a shrink wrap
Gold Peak Alkaline (1.5 V/0 mAh) Battery; Size N
Gold Peak LI-MNO2 CR2025 3 V
SAFT Li-SOCl2 AA 3.6 V
Ultralife 9 volt lithium battery
Lithium 3 V Button Cell CR2032, blister of 1
L91 Lithium AA 1.5 v Battery
CSL Dualcom replacement batt
HON DOM ADT 4VOLT 3.5 AHR batt
ELM battery for LED module
Duracell 7K67J for EMS PA
FLI 3 v coin cell battery in blister of 1
3.6 v 13 Ah Saft Battery (for Optex RF Beams)
SUCRE Replacement Re-charchable AAA Battery
Duracell Lithium/Manganese Dioxide Battery 3.0 V
For EMS 7970 PA buttons
Panasonic 3 v lithium coin cell, i
Tadrian 3.6 v 1/2 AA
4
Contacts
This chapter contains information about our range of Contacts
Introduction
Grade 3
Grade 2
High Security
Non Graded
09/16
1
Contacts
Introduction
Range and Grading
An extensive range of high quality Magnetic
Contacts providing a choice of both Surface
and Flush mounting, with options of ‘Cabled’ or
‘Terminal’ Contacts within these ranges.
Application Notes
Consideration should be given to the fitting of
contacts on or within a ferrous material (e.g. steel),
which will usually reduce the operating gap. Some
contacts can be supplied with spacers to distance
the contact and magnet from a ferrous surface if
required; see specification tables.
Our Magnetic Contacts are Graded with respect to
EN50121-2-6:2008 and PD6662:2010 with options
available at Grades 1, 2 and 3. The Grade 3, EN3-RSA The ‘High Security’ range of contacts requires
and High Security VS303 are also CPNI approved.
correct orientation with respect to contact and
magnet and accurate alignment for successful
Terminal Contacts
operation. The VS222 Roller Shutter and the HDBR‘Terminal’ Contacts are Environmental Class II and
SO contacts are available in a reversed (REV) version
available in both Surface & Flush fitting, supplied
if required.
fitted with resistors of your choice for use in FSL
systems and in most cases can also be used in
Contacts with Integral Resistors
Double Pole systems (check specification). Terminal Where Contacts are supplied with Integral Resistors,
Contacts benefit from a quality spring action micro
Cabled or Terminal, a Colour Code is used to make it
switch providing reliable tamper protection.
easy for you to match them to your chosen control
panel, ensuring you have the correct value resistors
Cabled Contacts
built into the Contact.
‘Cabled’ Contacts are Environmental Class III and
are also available in both Surface and Flush fitting;
cabled contacts are potted providing life long
protection against the ingress of moisture, most are
available in 4 or 6 wire versions.
4 wire Contacts are suitable for use in double pole
systems, whereas 6 wire Contacts (patent pending)
include integral resistors for use in FSL systems but
with the added benefit that they can still be used
in a double pole system, thus offering maximum
versatility. Contacts can be configured to single or
multiple doors in each case.
09/16
2
Contacts
Grade 3
Contacts - Grade 3
Description
Order Codes
EN3-QFC-GN
White 20 mm Plastic Flush, Cabled Contact for use on Wood or
Aluminium. Integral Resistors, for use in FSL or DP systems,
single or multiple doors. Incorporating magnetic detection/
immunity.
White 20 mm Plastic Flush, Cabled Contact for use on Wood or
Aluminium. Integral Resistors, for use in FSL or DP systems,
single or multiple doors. Incorporating magnetic detection/
immunity.
EN3-QFC-BNGN
EN3-QSC-GN
Small White Surface Plastic, Contact for use on Wood or
Aluminium. Integral Resistors, for use in FSL or DP systems,
single or multiple doors. Incorporating magnetic detection/
immunity.
Small Brown Surface Plastic, Contact for use on Wood or
Aluminium. Integral Resistors, for use in FSL or DP systems,
single or multiple doors. Incorporating magnetic detection/
immunity.
EN3-QSC-BNGN
EN3-LSC-GN
Large White Surface Plastic, Contact for use on Wood or
Aluminium. Integral Resistors, for use in FSL or DP systems,
single or multiple doors. Incorporating magnetic detection/
immunity.
EN3-LSC-BNLarge Brown Surface Plastic, Cabled Contact for use on Wood or GN
Aluminium. Integral Resistors, for use in FSL or DP systems,
single or multiple doors. Incorporating magnetic detection/
immunity.
EN3-RSA-GN
Roller Shutter Contact, Integral Resistors, for use in FSL or DP
systems, single or multiple doors. Incorporating magnetic
detection/immunity.
Heavy Duty service Aluminium Contact with 8 Terminals and 1K
Resistor.
Large white surface contact with 6 Term and selectable EOL
resistor values and tampers
09/16
YM101KR
SC570-WHMD-MULTI-G3
3
Contacts
Grade 3
Grade 3 Specifications
Flush
Grade
3
EN-QFC-GN
EN3-QFCBN-GN
Application
Cabled/Terminals
Suitable for Wood
or Metal
Fixing
Operation Mode
Single/Multiple
Doors
Special Features
Material
Colour
Contact Details
Magnetic Detection/
Immunity
Operating GapMinimum Close
(mm)
Resistors Fitted
Number of Wires or
Terminals
S/Steel Cable
protection
Encapsulation
09/16
Surface
3
EN3-LSCGN
EN3-LSCBN-GN
Cabled
3
EN3-RSAGN
3
YM101KR
3
SC570WH-MDMULTI-G3
Cabled
3
EN3-QSCGN
EN3-QSCBN-GN
Cabled
Cabled
Terminal
Terminal
Wood or
Metal
Screws
FSL of DP
Single or
Multiple
Magnetic
Immunity
Wood or
Metal
Screws
FSL of DP
Single or
Multiple
Magnetic
Immunity
Wood or
Metal
Screws
FSL of DP
Single or
Multiple
Magnetic
Immunity
ABS
White or
Brown
Immunity
ABS
White or
Brown
Immunity
ABS
White or
Brown
Immunity
Wood or
Metal
Screws
FSL of DP
Single or
Multiple
Magnetic
Immunity &
Detection
Aluminium
Silver
Wood or
Metal
Screws
FSL of DP
Single or
Multiple
Magnetic
Immunity &
Detection
Aluminium
Silver
Wood or
Metal
Screws
FSL of DP
Single or
Multiple
Magnetic
Immunity &
Detection
ABS
White
Detection
Detection
Detection
13
9
7
22
20
12
Yes
6W
Yes
6W
Yes
6W
Yes
6W
Yes
8W
Yes
3W
No
No
50cm
Potted
Potted
Potted
Potted
4
Contacts
Grade 3
Grade 3 Specifications Cont.
Flush
Grade
3
EN-QFC-GN
EN3-QFCBN-GN
Contact Dimensions
& Fixings
Length (mm)
Width (mm)
Depth (mm)
Flange (mm)
Body Diameter
(mm)
Cable Length (mm)
Fixings
Magnetic Details
Length (mm)
Width (mm)
Depth (mm)
Flange (mm)
Body Diameter
(mm)
Fixings
Classifications
TS50131-2-6 Grade
Environmental
Class
09/16
Surface
3
EN3-LSCGN
EN3-LSCBN-GN
93
3
EN3-RSAGN
3
YM101KR
3
SC570WH-MDMULTI-G3
N/A
3
EN3-QSCGN
EN3-QSCBN-GN
70
150
170
85
N/A
15
36 x 22.5
20
17
15
N/A
N/A
25
25
N/A
N/A
40
14
N/A
N/A
23
22
25
21
100
Screws
N/A
100
Screws
70
100
Screws
93
100
Screws
73
Screws
170
Screws
85
N/A
25
36 x 22.5
20
17
15
N/A
N/A
25
25
N/A
N/A
60
40
N/A
N/A
23
22
18
21
Screws
Screws
Screws
Screws
Screws
Screws
3
3
3
3
3
3
III
III
III
III
II
II
5
Contacts
Grade 2
Contacts - Grade 2
Description
Order Codes
6SM-GN
Small metal surface fitting unit designed to work on wooden or
metal doors.
LST-GN
Large size surface fitting unit with terminals, designed to work
on wooden or metal doors.
6SL-GN
Medium surface contact designed to work on large wooden or
metal doors.
6PHD-GN
Large surface contact designed to work on large or metal doors.
09/16
Medium surface contact designed to work on large wooden or
metal doors.
QST-GN
Medium surface contact designed to work on large wooden or
metal doors. Available in brown only.
QST-BN-GN
6
Contacts
Grade 2
Contacts - Grade 2
Description
Order Codes
Large surface contact designed to work on large or metal doors, 6HDSO-GN
has built in standoff.
Heavy duty unit aluminium with 8 terminals.
VHDA-GN
Large surface contact designed to work on large wooden or
metal doors.
6HD-GN-SS
Small roller shutter contact designed to work on large wooden
or metal doors. Note: Non-handed
6RSL-100-GN
Large Roller shutter contact designed to work on large wooden
or metal roller shutter doors. Note: Non-handed.
6RSA-100-GN
Direct replacement for old part number 1019.
09/16
A small flush fitting unit designed to work on wooden doors.
6QFC-GN
A small flush fitting unit designed to work on wooden doors.
Available in brown only.
6QFC-BN-GN
A small white flush fitting unit designed to work on wooden
doors, 6 terminals with tamper cover.
QFT-GN
A small brown flush fitting unit designed to work on wooden
doors, 6 terminals with tamper cover.
QFT-BN-GN
7
Contacts
Grade 2
Contacts - Grade 2
Description
Order Codes
Large flush fitting unit designed to work on wooden or metal
doors.
6MDP-GN
Large surface contact designed to work on large wooden or
metal doors, has built in standoff.
6HDBR-SO-GN
Large Roller shutter contact designed to work on large wooden
or metal roller shutter doors.
6VS222-GN
Note: This is a handed model and must not be confused
with the basic model 6RSA-100-GN.
The contact would be fitted to the LEFT side of a roller
shutter door when stood inside the building looking
towards the outside. For the version to fit to the RIGHT
side of a roller shutter door when stood inside the building
looking towards the outside, part code would be
6VS222-GN-REV available as an NSL from Elmdene.
Large surface contact designed to work on large wooden or
metal doors.
6VS302-GN
* NOTE: Please see the following pages of charts for more detailed information regarding the above
contacts.
09/16
8
Contacts
Grade 2
Grade 2 Specification
Grade Model
2 6S-GN
2 6SM-GN
2 LST-GN
2
6SL-200-GN 6SL
6SL-200-BN-GN
2
6SL-GN
6SL-BN-GN
Application
Small
Surface
fitting unit
designed
to work on
wooden
or metal
doors
Small metal
Surface
fitting unit
designed
to work on
wooden or
metal doors
Medium surface
contact designed
to work on large
wooden or metal
doors
Medium
surface
contact
designed
to work
on large
wooden or
metal doors
Material
Colours
ABS
White
Anodised
Silver
Medium
size fitting
unit with
terminals
designed
to work on
wooden
or metal
doors
ABS
White
ABS
White or Brown
Contact Length
Width
Depth
Magnet Length
38 mm
14 mm
8.5mm
38 mm
38 mm
16 mm
9.5 mm
38 mm
86 mm
25 mm
20 mm
86 mm
65 mm
12 mm
12 mm
65 mm
ABS
White or
Brown
65 mm
12 mm
12 mm
65 mm
Width
Depth
Reed Type No.
of Reeds
Operating
Gapmax
Encapsulation
Protection
Amount of
Cable wires
Cable Length
Cable Protection
S/Steel
2 x 1K/1K for
EOL
EN50131/
PD6662 grade
14 mm
16 mm
8.5 mm
9.5 mm
Standard 1 Standard 1
25 mm
12 mm
20 mm
12 mm
Standard 1 Standard 1
12 mm
12 mm
Standard 1
Standard 1
25 mm
15 mm
40 mm
15 mm
15 mm
20 mm
Potted
IP67
6
Potted
IP67
6
6 Terminals Potted
N/A
IP67
0
6
Potted
IP67
6
Terminals
IP43
Terminals
1m
No
1m
No
6 Terminals 2 m
N/A
No
1m
No
N/A
No
EOL
EOL
EOL
EOL
EOL
EOL
2
2
2
2
2
2
09/16
2
QST-GN
QST-BNGN
Medium
surface
contact
designed
to work
on large
wooden
or metal
doors
ABS
White or
Brown
67 mm
14 mm
13 mm
67 mm
14 mm
9
Contacts
Grade 2
Grade 2 Specification
Grade Model
Material
Colours
Contact Length
Width
Depth
Magnet Length
ABS
White
80 mm
20 mm
12 mm
80 mm
2
6HDSO-GN
Small metal
surface fitting
unit designed to
work on wooden
or metal doors,
has built in
standoff
Anodised
Silver
80 mm
32 mm
45 mm
80 mm
Width
Depth
Reed Type
No. of Reeds
Operating Gapmax
Encapsulation
Protection
Amount of
Cable wires
Cable Length
Cable Protection
S/Steel
2 x 1K/1K for
EOL
EN50131/
PD6662 grade
20 mm
12 mm
Standard
1
15 mm
32 mm
45 mm
Standard
1
25 mm
25 mm
25 mm
Standard
1
50 mm
55 mm
35 mm
Standard
1
70 mm
70 mm
35 mm
Standard
1
70 mm
Potted
IP67
6
Potted
IP67
6
terminals
N/A
0
Potted
IP67
6
Potted
IP67
6
1m
No
1m
Option
8 Terminals
Yes
1m
50c m
1m
50 cm
EOL
EOL
EOL
EOL
EOL
2
2
2
2
2
Application
09/16
2
6PHD-GN
Large surface
contact to
work on large
wooden or
metal doors
2
VHDA-GN
Heavy duty
Ali with 8
Teminal
2
6RSL-1000-GN
Small Roller
Shutter contact
designed to work
on large wooden
or metal doors
2
6RSA-GN
Large Roller
Shutter contact
designed to
work on large
wooden or metal
doors
ABS
Silver
170 mm
25 mm
25 mm
170 mm
ABS
Silver
94 mm
40 mm
15 mm
50 mm
ABS
Silver
175 mm
52 mm
15 mm
85 mm
10
Contacts
Grade 2
Grade 2 Specification
Grade Model
2
6F-GN
2
6QFC-GN
6QFC-BN-GN
A small flush fitting
unit designed to
work on wooden or
metal doors
2
QFT-GN
QFT-BN-GN
A small flush fitting
unit designed to
work on wooden
doors 6 terminals
with tamper cover
ABS
White or Brown
15 mm
36 mm x 22.5 mm
0 mm
ABS
White or Brown
15 mm
36 mm x 22.5 mm
0 mm
ABS
White
34 mm
38 mm (Oval)
24 mm
20 mm
20 mm
12 mm
Push In
34 mm
8 mm
N/A
2 Screws
15 mm
36 mm x 22.5 mm
0 mm
2 Screws
15 mm
36 mm x 22.5 mm
0 mm
2 Screws
34 mm
38 mm (Oval)
24 mm
8 mm
Push In
Standard
1
10 mm
20 mm
2 Screws
Standard
1
18 mm
20 mm
2 Screws
Standard
1
18 mm
12 mm
2 Screws
Standard
1
7 mm
Potted
No
6
Potted
No
6
Terminals
No
2
Potted
No
6
1m
No
EOL
2
1m
No
EOL
2
Terminals
No
EOL
2
1m
No
EOL
2
Application
A pencil type
flush fitting unit
designed to
work on
wooden or
metal doors
Material
ABS
Colours
White
Contact Length
34 mm
Diameter Flange 8 mm
Diameter standoff N/A
Flange
Diameter Body
8 mm
Fixings
Magnet Length
Diameter Flange
Diameter standoff
Flange
Diameter Body
Fixings
Reed Type
No. of Reeds
Operating Gap
max
Encapsulation
Protection
Amount of cable
wires
Cable Length
Cable Protection
2 x 1K/1K for EOL
EN50131/
PD6662 grade
09/16
2
6MDP-GN
Large flush fitting
unit designed to work
on wooden or metal
doors
11
Contacts
Grade 2
Grade 2 Specification
Grade Model
Model
Cabled / Terminals
Ferrous Material
Operation Mode
Single / Multiple
Doors
Special Features
Spacers Available
Fixing
Material
Colours
Operating GapMinimum Close
(mm)
Number of Reeds
Biased Reeds
Tamper
Resistors Fitted
Number of Wires or
Terminals
Stainless Steel Cable
Protection
Encapsulation
Length (mm)
Width (mm)
Depth (mm)
Flange (mm)
Body Diameter (mm)
Magnet
Cable Length (cm)
EN50131-2-6 Grade
CPNI
BVVO*
NCP*
INCERT*
Environmental Class
Protection
09/16
Flush
2
6HDBR-SO-GN
Cabled
Yes
4 wire - DP 6 wire - FSL &
DP
Single or Multiple
Surface
6VS222-GN
Cabled
Yes
4 wire - DP 6 wire - FSL
& DP
Single or Multiple
2
L6VS302-GN
Cabled
Yes
4 wire - DP 6 wire - FSL
& DP
Single or Multiple
Multiple Reeds Passive
Tamper
N/A
Multiple Reeds Active
Tamper
N/A
Multiple Reeds Passive
Tamper
N/A
Screws
Aluminium
Silver
17
Screws
Aluminium
Silver
10
Screws
Aluminium
Silver
10
3
1
Passive
6 wire version
4W
4
2
Active
6 wire version
6W
3
3
Passive
6 wire version
4W
50 cm
50 cm
50 cm
Potted
80
32
45
N/A
N/A
As Contact
100
2
n/a
n/a
n/a
n/a
III
IP67
Potted
175
52
15
N/A
N/A
85 x 70 x 35
100
2
n/a
n/a
Potted
109
38
19
N/A
N/A
As Contact
100
2
n/a
n/a
III
IP67
12
Contacts
Non Graded
Non Graded
Description
Order Codes
QF-5
A small white flush fitting contact designed to fit on wooden
doors 5 x terminals.
QF-5-BN
A small brown flush fitting contact designed to fit on wooden doors
5 x terminals.
Grade
Model
Application
Material
Colours
Contact Length
Diameter Flange
Diameter standoff Flange
Diameter Body
Fixings
Magnet Length
Diameter Flange
Diameter standoff Flange
Diameter Body
Fixings
Reed Type
No. of Reeds
Operating Gap max
Encapsulation
Protection
Amount of cable wires
Cable Length
Cable Protection
2 x 1K/1K for EOL
EN50131/ PD6662 grade
09/16
1
QF-5
QF-5-BN
A small flush fitting contact with 5 terminals and no resistors
to work on wooden doors
ABS
White or Brown
15 mm
36 mm x 22.5 mm
0 mm
20 mm
2 Screws
15 mm
36 mm x 22.5 mm
0 mm
20 mm
2 Screws
Standard
1
18 mm
N/A
No
0
0
No
No
1
13
Contacts
Accessories
Spacers
These spacers will help in aligning up the magnet
to reed contact on doors that are off set or need a
small amount of levelling up. The spacers can be
used on both the magnet and or the door contact.
Features:
There are 5 different types to suit most of the
surface range and in Aluminium, brown and white
versions.
Description
Order Codes
4HD-SPC
3.0 mm Spacer for use with HD type Contacts, 6HDSO-GN
LSC-SPC
Pack of 5, 2.5 mm Spacers for LST-GN & EN3-LSC-GN Contacts
LSC-SPC-BN
Pack of 5, 2.5 mm Brown Spacers for EN3-LSC-BN-GN Contact
QSC-SPC
Pack of 5, 2.5 mm Spacers for QSC-GN & EN3-QSC-GN
Contacts
QSC-SPC-BN
Pack of 5, 2.5 mm Brown Spacers for EN3-QSC-BN-GN Contact
09/16
14
Day Alarms
This chapter contains information about our range of Day Alarms
Introduction
Multiguard
Exitguard
Aidalarm
Zoneguard
09/15
1
Day Alarms
Introduction
We have a number of power supply units and
batteries to suit your needs.
Elmdene Produce a range of 12 V dc standalone
power supplies for a wide range of applications
including Intruder, Fire, CCTV, Access Control and
General Purpose use in both Linear and Switch
Mode formats.
Our range of B style Boxed power supplies are
formed from 1.2 mm powder coated steel and
finished in white, with hinged lids.
All Elmdene power supplies carry the CE mark and
conform to EN60950:2000, EN50130-4:1995 and
EN50081-1:1992 in addition to standards specified
for individual ranges on the relevant pages.
This Power RIO (P026-01-B) can be used for the
Galaxy G2 and Dimension panels. The Galaxy Power
Rio consists of 2 modules, the Power Block and
the Control Unit. The PSU can be connected to the
control panel via the RS485 (AB) line.
The PSU can be used in place of a standard RIO to
overcome power problems that arise when the
additional RIO is fitted distant to the control panel. A
6-way jumper lead connects the Power Block to the
Control Unit.
All PSU’s conform to either grade 2 or 3 under
PD6662:2010 / EN50131-6:2008.
09/15
2
Day Alarms
Multiguards
Multiguard
Features:
Integral P.S.U. & Battery Option
Integral Piezo Sounder
Unique Labelling System
Open or Closed Circuit Inputs
D.P.C.O. Global Output Relay
Lamp Test Option
Emergency re-call Facility
Possible uses for the Multiguard are Perimeter
Protection Systems, Personal Attack Monitoring,
Fire Exit Door Monitoring (e.g. EXITGUARDs/
AIDALARMs) and Nurse Call Systems. There are
also many other applications in the field of process
monitoring such as Deep Freeze Alarms.
Technical Specifications:
MG212000 & MG212100 General purpose
annunciators.
Order Codes:
These Multiguards are the basic versions used for
general purpose monitoring where zone isolation is
not required.
The MG212100 is fitted with an integral 12 v 250 ma
PSU and standby rechargeable battery. In all other
respects these two versions are identical.
When an alarm condition is detected an audible
warning is given by the integral piezo sounder,
the relevant zone LED flashes, and a global relay
energises to provide volt free DPCO contacts for
signalling to other equipment.
09/15
Dimensions:
Power:
Current:
609.001.202
609.001.203
S1778PR
609.001.211
609.001.214
H XW X D
90 x 156 x 57 mm
12 vdc
250 mA
Hoyles Multiguard 6ZN
MG212100
Hoyles Multiguard EXT
MG212000
Overdoor light and buzzer
with 8 red LEDs white
plastic plate
S1600
Hoyles 30 Sec Timer Relay
S312T
3
Day Alarms
Exitguard
Exitguard
Features:
High Power Piezo Sounder
Keypad Control
Auto Reset / Re-arm Delays 0 - 88s
Separate Door Open Too Long
Keypad & Auto re-arm. 0s - 88s
Bleep In Off option
Front & Back Acting Tamper Switch
Selectable Alarm Tones
Visual Alarm Indication
Chime Facility
Alarm Relay Output
On - Off Monitor Relay
Fire Door Checker
This new EXITGUARD uses a nine digit keypad for
both control and programming. The tone of the high
power integral alarm can be selected to distinguish
it from other alarms. The alarm can be silenced and
reset using a four digit code or the EXITGUARD
can re-arm automatically after a preset delay once
the door has been closed. Separate Door Open
Too Long (DOTL) delays can be set for Code Reset
and Auto Reset modes. There is also a Bleep In Off
option and Chime facility. There are a number of
different models to suit various applications:
Technical Specifications:
Dimensions:
Power:
Current:
Order Codes:
EX204
EX205
09/15
H XW X D
90 x 156 x 57 mm
204 - 6 x AAA Batteries
7-14 vdc
205 - 11-14 vdc
204 - 80 mA
205 -155 mA
Battery Powered
12 vdc Powered
4
Day Alarms
Aidalarm
AIDALARM A600M Mains
Features:
DDA Compliant
BS8300 Compliant
High Power Piezo Sounder
12 Vdc & Mains Versions
Audible & Visual Signalling
Range of Accessories
Selectable Alarm Tones
Remote Signalling Output
Choice of Four Warning Tones
No Part B Building Regulation Conflicts
AIDALARM A600M Mains/12 vdc Powered
This is similar to the A600B but can be used to
create a more comprehensive system with the
addition of a remote reset button, remote indicator/
mute unit with separate LED and sounder controls
or overdoor light / sounder.
Technical Specifications:
The A600M is fitted with a volt free output relay for
connection to a MULTIGUARD indicator or a building
management system. The A600M can be powered
from either 12 volts dc from an external power
supply or from 230/240 vac mains power. There is
also an option for a rechargeable standby battery
(not supplied) when powered from the mains
supply.
Order Codes:
The integral 12 volt dc supply will provide power for
external items such as overdoor lights etc.
Dimensions: H X W X D
90 x 156 x 57 mm
Power:
12 dc or 240 vac
Current:
Output 200 mA
609.001.206
609.001.211
609.001.212
609.001.214
609.001.215
S1778SR
609.001.312
A600M
6504
6698
609.001.211
09/15
Hoyles Light/Sounder S1678
Hoyles Pullcord/LED S1600
Hoyles Reset Button S1608
Hoyles 30 SEC Timer
RelayS312T
Multipurpose Relay
Over door A/V unit stainless
steel
Hoyles S1608P Reset
Button S/M
Hoyles mains/12VDC
powered Aidalarm
Hoyles S312N DBL Pole
Relay
Hoyles S320 SGL Pole
Relay
Hoyles Replacement cord
for S1600 pull cord
5
Day Alarms
Zoneguard
Zone Omit Modules
Features:
Complies with EN50131 Grade 3
Designed for detectors with separate alarm, antimasking and tamper facilities
Integral high security keyswitch 250,000+ differs
Integral 9 digit keypad 500,000 differs
Dual responsibility or combination mode gives
over 300 million differs
Zone status LEDs, Fault LED
Integral piezzo sounder
Output for remote sounder, Independent zone
omitted relay
Input for remote devices, keyswitches, shunt
locks, biometric readers etc..
User programmable code change/Timed entry/
exit modes
Grade 3 passive infra red/DualTec detection devices
must be fitted with independent anti-masking and
tamper detection.
In its simplest mode ZONEGUARD uses its integral
keyswitch to omit or reinstate up to two detection
zones.
Other modes are available using the integral keypad
or external devices such as biometric reader or a
combination of keyswitch and keypad, this is useful
where dual responsibility is essential. Two timed
entry/exit modes are also available.
09/15
Technical Specifications:
Dimensions: H X W X D
90 x 156 x 57 mm
Power:
12 vdc
Current:
Output 120 mA
Order Code:
ZG800
Zone Omit Module
6
Detectors
This chapter contains information about our range of Detectors
Introduction
Beams
Glassbreak
Dualtech
Sequential Confirmation
Passive Infra-Red
Vibration
09/16
1
Detectors
Introduction
Photoelectric beam systems detect the presence
of an intruder by transmitting visible or infrared light
beams across an area, where these beams may be
obstructed. To improve the detection surface area,
the beams are often employed in stacks of two
or more. A glassbreak detector is a sensor used
in electronic intruder alarms that detects if a pane
of glass is shattered or broken. These sensors are
commonly used near glass doors or glass store-front
windows to detect if an intruder broke the glass and
entered.
independently to the control panel and consequently
the ARC (Alarm Receiving Centre) in the event of an
activation.
Glassbreak detectors usually use a microphone,
which monitors any noise or vibrations coming
from the glass. If the vibrations exceed a certain
threshold (that is sometimes user selectable) they
are analyzed by detector circuitry. Simpler detectors
simply use narrowband microphones tuned to
frequencies typical of glass shattering, and react
to sound above certain threshold, whereas more
complex designs compare the sound analysis to
one or more glass-break profiles and react if both
the amplitude threshold and statistically expressed
similarity threshold are breached.
All objects above absolute zero emit heat energy
in the form of optical radiation (light). Usually this
light is invisible to the human eye because body
temperature radiates at infrared wavelengths, but it
can be detected by electronic devices designed for
such a purpose.
A choice of dual PIR or Dual technology sensors are
available to suit most applications
A passive infrared sensor (PIR sensor) is an
electronic sensor that measures infrared (IR) light
radiating from objects in its field of view. They are
most often used in PIR-based motion detectors.
Vibration: These devices are mounted on barriers
and are used primarily to detect an attack on the
structure itself. The technology relies on an unstable
mechanical configuration that forms part of the
electrical circuit. When movement or vibration
occurs, the unstable portion of the circuit moves and
Dual Technology devices usually encompass PIR and breaks the current flow, which produces an alarm.
Microwave. PIR activates on movement of warm
The technology of the devices varies and can be
objects against a background level whilst microwave sensitive to different levels of vibration. The medium
transmits a signal and monitors the return signal
transmitting the vibration must be correctly selected
and any “new” object in front of the device alters
for the specific sensor as they are best suited to
this signal. As PIR and Microwave detect different
different types of structures and configurations.
phenomena they are not subject to the same false
alarm sources but are equally good at detecting real Most sensors use piezo-electric components rather
alarm events.
than mechanical circuits, which can be tuned to be
extremely sensitive to vibration.
Sequential Confirmation Detectors ; BS2843:2010
& EN 50131-2-4 / EN 50131-1 / PD 6662 2 detectors They are very reliable sensors, with low false alarm
within the sensor are non-overlapping and have
rate and middle place in the price range.
separate relay outputs. These outputs signal
09/16
2
Detectors
Beam Detectors
Photoelectric Beam Detectors
Features:
Twin Synchronised Pulsed Beams
Designed for Greater Stability
Selectable 4-Channel Beam Frequencies
Adjustable beam interruption time - long
interruption time catches an intruder but allows a
small animal to pass through
Twin beams require simultaneous interruption to
create activation
99.5% beam blocking stability
Easy installation and alignment using viewfinder
for rough alignment and voltage meter jacks for
fine-tuning
Sealed optics to prevent ingress of insects and
dust
The AX-70/130TN Twin beam photoelectric sensors,
designed for short-range outdoor or long-range
indoor applications. Using twin beams of pulsed
infrared energy, reliable operation is possible in
the worst conditions - up to 99% of the emitted
radiation can be blocked by rain, fog or falling snow
and the beams will still operate.
Order Codes:
AX-200TF is a compact photoelectric detector with
“the IP65 high durability”, and “stable detection
performance”. These features reduce false alarms
drastically - caused by outdoor severe environmental
changes and provide a wide range of applications.
AX-200TF
AX-70TN
AX-130TN
Optex External/Internal
Synchronised twin beam,
20 m outside range
Optex External/Internal
Synchronised twin beam,
40 m outside range
(BE) Optex External/Internal
Synchronised twin beam,
60 m outside range
AX-350/650TF Series photobeams are dual beam
longrange sensors with a host of sophisticated extra
facilities.
They are ideal for larger installations where they are
capable of external ranges up to 200 m. The beams
offer four site-selectable frequencies that allow
them to be stacked one above another to provide a
wall of coverage.
To reduce setup and alignment time to a minimum,
AX-350/650TF units include a one-man alignment
facility.
09/16
3
Detectors
Beam Detectors
AX-100/200TFR
Features:
The new AX-100TFR and AX-200TFR from OPTEX
is a revolution in the perimeter security industry,
offering a significant cost saving alternative to
traditional hardwired system. No trenching is
required, drastically reducing installation costs. The
unit comes wireless ready with a multifunctional
back box and is compatible with most
manufactures wireless systems.
The AX-TFR series uses four 3.6 V batteries with an
average lifespan of 5 years on the 100f t model and
3 years on the 200 ft model.
Long battery life AX-100TFR: approx. 5 years AX200TFR: approx. 3 years
Easy battery replacement
Triple tamper functions
Low battery output and LED indication
Intermittent output function
Compatible with numerous wireless transmitters
Battery saving timer function for wireless
transmitters
International protection IP55
Easy angle adjustment function
Beam interruption adjustment function
99% Beam blocking stability
N.C./N.O. output selection switch
4 selectable beam frequencies
Order Codes:
OPX 30 m RF Twin Beam
unit
OPX 60 m RF Twin Beam
unit
Battery for AX-TFR 3.6 v 13
Ah (SAFT)
AX-100TFR
AX-200TFR
LSH20
Note: When using these on a Galaxy System, you
will need an RF Portal C079-2, in addition to 2 x
DODT8M.
Model
Range
Maximum arrival
distance
Detection Method
Beam frequency
selection
Interruption period
Power Source
Cuurent Draw
Battery Life*
Transmitter
Receiver
Operating
Temperature
Weight
International
Protection
09/16
AX-100TFR
30 m
265 m
AX-100TFR
60 m
530 m
Infrared beam interruption detection
4 channel
Variable between 50,100, 250, 500 msec (4steps)
3.6V 13.0 Ah: LSH20 lithium batteries manufactured by SAFT (not installed)
Transmitter: 2 units Receiver
620μA T:300μA + R : 320 μA
810μA T:490μA + R : 320 μA
(at 25oC, 3.6 VDC)
(at 25oC, 3.6 VDC)
5 Years
3 Years
5 years
-20oC - +60oC
1600 g (Total weight of transmitter + receiver excluding accessories)
IP55
4
Detectors
Beam Detectors
Darwin Active InfraRed Beams
Features:
Interior and exterior use
Self alignment system
Quick and easy to install
Various sizes
Darwin is the new CIAS Active Infrared Barrier.
Manufactures with high quality aluminium it is very
strong and resistant, suitable for offsetting any
expansion due to temperature peaks.
Its small size (22.5X23 mm) makes it invisible when
it is installed between window casings.
Its modularity makes Darwin perfect for use with
different protection systems, both indoor and
outdoor. It is equipped with self-alignment system,
alarm LED and “Plug and Play” Fixing system which
makes it easy and quick to install the device. No line
synchronism is required as each ray is recognised
through separate optical codes. This results in
optical Synchronism with different and unique
identification codes for each single beam.
The alarm operation Logic is managed by a
micro-processor which automatically sets the
configuration of the beams as adjacent, crossed or
multiple according to ray interruption and speed of
interruption.
09/16
Order Codes:
616.017.100
616.017.101
616.017.102
616.017.103
616.017.104
Darwin Active Infra-red
Barrier for indoor and
outdoor Use
(2 beam, 0.5 m)
Darwin Active Infra-red
Barrier for indoor and
outdoor Use
(4 beam, 1m)
Darwin Active Infra-red
Barrier for indoor and
outdoor Use
(6 beam, 1.5 m)
Darwin Active Infra-red
Barrier for indoor and
outdoor Use
(8 beam, 2 m)
GPS Darwin Beam Brackets
(1x Pair). Each pack contains
a pair of brackets for one
side of the Beam unit
only. You will need 2 pairs
of brackets , for 1 set of
Beams
5
Detectors
Glassbreak Detectors
Aritech 5815NT-ART
Features:
250 percent better false alarm immunity
Adjustable to room size
All-new, easy-access design
Designed for quiet occupied areas on the
perimeter loop
Consistent detection, even of soft, quiet glassbreaks
Detects through blinds and light drapes
End-user can test sensor operation with a clap of
the hands
Alarm memory
The Aritech 5815NT-ART Series ShatterPro3™is
the latest breakthrough in Aritech’s advanced
series of acoustic glassbreak sensors. In lab tests,
ShatterPro3 provides 250 percent better false alarm
immunity than the popular ShatterPro.
II (GS 903N)
The coverage pattern can be easily adjusted to
fit small or large rooms. Interference outside the
range will not cause false alarms. The ShatterPro3™
detects in a full 360° coverage pattern, with a
maximum 7.6 m radius from sensor to glass.
Glass Type Thickness
Minimum size for all glass types is 28cm x 28cm,
square. Glass must be framed in the wall of the
room or mounted in a barrier of 0.9 m minimum
width.
Type Min.
Plate
Tempered
Laminated*
Wired
09/16
Thickness Max.
2.4 mm
3.2 mm
3.2 mm
6.4 mm
Thickness
6.4 mm
6.4 mm
6.4 mm
6.4 mm
Using Aritech’s patented Pattern Recognition
Technology, the sensor listens for actual patterns
of breaking glass while eliminating most false
alarm patterns. ShatterPro3™ listens across the
glassbreak frequency spectrum for greater false
alarm immunity.
Available with a round or rectangular housing,
ShatterPro3™ can be tested without opening
the sensor by activating the Aritech hand-held
glassbreak tester at close range. A simple hand-clap
feature lets end-users confirm at any time that the
ShatterPro3™ is operational.
Technical Specifications:
Input voltage:
9 to 16 Vdc
Current:
Typical 15 mA
Maximum
25 mA
Detection range:
0.9 - 7.6 m x 360°
Operating temperature:0° to 50°C
Dimensions:
115H x 70W x 20D mm
EN50131:
Grade 2
Order Code:
616.008.011
5815NT-ART ShatterPro3™
Rectangular Detector
6
Detectors
Glassbreak Detectors
Honeywell FG-1625TAS
Features:
FlexCoreTM Signal Processor
Easy Installation and Setup
Mount the Detector Anywhere
Covers All Glass Types
Multiple Domain Signal Analysis
Remote Test Mode Enable/Disable
Enclosed PC Board
Grade 3 EN50131
The new FG-1625TAS Glassbreak Detector uses
the latest technology to provide faster response
and increased false alarm immunity. The FG-26TAS
is designed to allow fast and easy installation.
Optimum operation can be quickly verified using the
FG-701 Glassbreak Simulator.
FlexCore™ Signal Processor
The FlexCore Signal Processor is an ApplicationSpecific Integrated Circuit (ASIC), which processes
sound data in parallel rather than sequentially; for
faster, more accurate detection decisions.
Technical Specifications:
Physical Dimensions: 98 mm x 62 mm x 21.8 mm
White high impact ABS plastic housing
Weight:
Product only
90 g
Pkgd. Product
116 g
Range:
15’ (4.6 m) maximum,
omni- directional no
minimum range
Alarm Relay:
FG-1625TAS Form A,
125 mA max. 25 Vdc max.
FG-1625TAS
Form C, 125 mA max.
25 Vdc max.
Alarm Duration: Five seconds (unaffected by alarm
LED latching)
ESD Immunity:
10kV discharges of either
polarity to exposed surfaces
Power Requirements:
6 to 18 VDC; 12 mA typical
at 12 Vdc, 22 mA max,
(Latched LED) AC ripple: 4 V
peak-to peak at Nominal
12 Vdc
RFI Immunity:
30 V/m, 10 MHz to 1000
MHz
Operating Temperature:
-10° to 50° C
Storage:
-20° to 50° C
09/16
The combination of proven FlexGuard® performance
with the speed of FlexCore processing provides
unmatched false alarm immunity without
compromising detection.
Easy Installation and Setup Intellisense’s patented
technology allows remote activation of Test Mode
(w/simulator). The FG-1625TAS has a centred wire
entry hole, 45° terminal blocks, and EOL terminals.
A hand-clap feature verifies that the detector is
functioning. No sensitivity adjustments are required.
Order Code:
FG-1625TAS
FG-1625TAS Glassbreak
Detector
Glass Type Thickness
Minimum size for all glass types is 28 cm x 28 cm,
square. Glass must be framed in the wall of the
room or mounted in a barrier of 0.9m minimum
width.
Type Min.
Plate
Tempered
Laminated*
Wired
Coated**
Sealed
Insulating*
Thickness Max.
2.4 mm
3.2 mm
3.2 mm
6.4 mm
3.2 mm
3.2 mm
Thickness
6.4 mm
6.4 mm
14.3 mm
6.4 mm
6.4 mm
6.4 mm
7
Detectors
Glassbreak Detectors
Honeywell FG-1625Z
Features:
Only Listens for Sounds Coming from Glass
Superior False Alarm Immunity
Field Proven Glassbreak Protection
Installer Friendly Installations
Ceiling Mount Detector
Fast and Accurate Testing
Easily Verify Detector Operation at Any Time
The FG-1025Z performance is achieved through
the use of 2 microphones and Time-of-Arrival (TOA)
processing. When a sound is generated in the room,
the microphone nearest the sound will hear it first.
The Micro-controller in the unit monitors all sound
events received by the microphones and processes
only those received first at the ‘front’ microphone,
which is pointed toward the protected zone. Sounds
arriving at the ‘back’ microphone first are simply
ignored.
Because of the symmetry of the unit, the space
surrounding the front and back microphones is
divided evenly between protected and excluded
zones. A region 20 degrees wide on each side of
the unit is the keep-out zone. In this region sound
may or may not be processed. Glass to be protected
should never be within the keep-out zone. However,
false-alarm rejection is still high in this region.
Order Code:
Technical Specifications:
5442
FG-1625Z Break Glass
Detector
Glass Type Thickness
Minimum size for all glass types is 28 cm x 28 cm,
square. Glass must be framed in the wall of the
room or mounted in a barrier of 0.9 m minimum
width.
Type Min.
Plate
Tempered
Laminated*
Wired
Coated**
Sealed
Insulating*
09/16
Thickness Max.
2.4 mm
3.2 mm
3.2 mm
6.4 mm
3.2 mm
3.2 mm
Thickness
6.4 mm
6.4 mm
14.3 mm
6.4 mm
6.4 mm
6.4 mm
Dimensions:
Glassbreak Detector:108 mm x 22.4 mm x
23 mm (ø x d)
Weight:
128 g
Range:
7.6 m Maximum
Mounting Locations: Ceiling
Alarm Relay:
Form C(NO/NC)\125 mA @
25 Vdc
Alarm Duration:
5 Seconds (unaffected by alarm
LED latching)
Tamper Switch: Combination cover and wall
tamper, 25 mA @ 24 Vdc
Power Requirements: 8-14 Vdc, 25 mA @ 12 Vdc
AC ripple:
4 volts peak to peak at
Nominal 12 Vdc
Operating Temperature:
0°C-49°C
ESD Immunity:
10 kV; discharges of either
polarity to exposed surfaces
Command Input/Remote
LED Enable:
Active low (0 – 1.5 V). High
impedance for inputs less than
5.6 V 20 mA/16 V max.
Approvals:
UL Listed, PD6662 Security
Grade 2, Environmental Class I
8
Detectors
Dualtech’s
DD100PI
Features:
PIR verified by microwave module
“Step & Gliding Focus Multi-Curtain” mirror optic
Plug-in electronics
Sealed optics E
ASIC with “4D” processing
Distance of Motion microwave signal processing
Selectable range with full undercrawl detection
Complies with EN50131-2-2
The DD100 series of detectors makes no
compromises because it is a dual technology
detector. It utilizes all the good features of our
PIRs, including sealed Gliding Focus Mirrors and
the latest 4D signal processing. Add to the high
quality microwave, where the latest design using
Twin Opposed Antennae has been used to ensure
a better signal to noise ratio and better microwave
direction. The end results are products with sharp
detection and excellent false alarm immunity.
Order Code:
DD100PI
09/16
Dual Technology Step and
Gliding FocusMulti Curtain
Mirror optics Passive Infra
Red/Microwave Detector,
wide angle (86o with 5
curtains) selectable range
10 m, volumetric PIR/W
motion sensor with Pet
Immunity up to 20 Kg
Technical Specifications:
Detection Range
10 m
Undercrawl Protection
Yes
Detection Range Selection
10 m or 6 m
Coverage Field of View
86o with 5 curtains
Coverage Pattern Selection
Undercrawl Blinder
Mounting Height
1.8 m to 3.0 m
Power Supply
9 to 15 Vdc
Current Consumption (nom.)
11.5 mA
Alarm Relay (voltage free)
NC when energised
Tamper Relay (voltage free)
NC when cover closed
Remote Control Lines
Walk test
Alarm Memory
No
Microwave Frequency (nom.)
2410MHz
Dimensions (WxHxD mm)
61 x 123 x 58
Ambient Conditions -10 to +50oC max, 95%
Relative Humidity
Pry-off Tamper
ST400 (optional)
EN50131-2-2
Grade 2
9
Detectors
Dualtech’s
DT900 Range
Features:
Digital Fluorescent Light Filter
Three Micro-controller-based
Sensitivity Modes
Zero Clearance Bug Guard
Small Animal immunity
Installer-Friendly Design
LED Diagnostics
EN50131 Grade 3
The DT900 is designed specifically for tough
commercial and industrial applications. The use
of three Micro-controller based sensitivity modes
(M.A.P.TM processing) gives the DT900 excellent
detection capability while virtually eliminating false
alarms. Sensor self-adjustment ensure reliable
performance in a variety of climates and conditions.
Technical Specifications:
The DT900s long range detection pattern, vandal
resistant housing and zero clearance bug guard
make it ideal for protecting warehouses, factory
floors, retail outlets, open indoor space etc.
Anti-Mask & Trouble
Relays:
NC
30 Vdc, 25 mA
Power Requirements:
10.15 Vdc: 35 mA (max)
Operating Temperature:
0° to 49°C, 5 % to 95%
relative humidity,
non-condensing
PIR White Light
Immunity:
6500 LUX
RF Immunity:
30 V/m, 10MHz to 1000 MHz
Input 1 & 2:
Self-test initiate: Active low 0
to 1.5 V, Inactive high 5 to V+
Optional Mounting
Height Range:
2 m minimum to 3.8 m
maximum
Microwave Frequency:
X-Band
ESD Immunity:
± 10 kV
EN50131
Grade 3
Order Codes:
DT900AM-UK
DT906AM-UK
09/16
DT900 Wide angle dual
technology detector, 27
metre range
DT906 Corridor dual
technology detector. 61
metre range
Dimensions:
Weight:
Alarm Relay:
Tampers:
200 x 170 x 150 mm
1.36 kg
Energised form C: 25 VDC,
125 mA
Top, wall & bottom cover
30 Vdc, 25 mA (N.C.)
10
Detectors
Dualtech’s
Risco Iwise GreenLine
Features:
The Iwise Green Line DT AM detectors are
the ultimate motion detectors for professional
installations, incorporating both Anti-MaskTM and
Anti-CloakTM Technologies (ACTTM ),
Dual MW & PIR Technologies
Anti-CloakTM Technology (ACTTM)
Coverage of 15 m and 25 m
“Green” setting - MW disabled during unset
Active IR Anti-Mask with separate relay
Built-in EOL resistors, jumper selectable
3 LED walk test indication
Cover and wall tampers
Set and LED control inputs
Creep zone
High RF immunity 30 V/m
Anti-fluorescent interference signal processing
Corridor lens (optional)
Technical Specifications:
adhering to new environmentally friendly guidelines
and complying with PD 6662 and EN 50131-1 Grade
3.
In response to the recent growth in environmental
awareness, Rokonet has implemented a new
“Green Line” concept in the Iwise DT AM G3
series, by effectively eliminating surplus MW
radiation during unset periods. Iwise Green Line
DT AM detectors are available in 15 m and 25
m models, and include built-in-end-of-line (EOL)
resistors to simplify installation.
Order Codes:
RK815DTG3TYB
RK825DTG3TYB
RL115CV
RL15VT
RL17V
09/16
Dual Technology Passive
InfraRed/Microwave
(10.587GHz) Detector, wide
angle (100o) 15 m or
6 m, with Antimask and
Anti-Cloak
Dual Technology Passive
InfraRed/Microwave
(10.587GHz) Detector, wide
angle (100º) 25 m, with
Antimask and Anti-Cloak
Technology, NC relay, ADT
logo
12 m Curtain Lens IWise G3
15 m IWISE G3 Long range
corridor Lens
23 m IWISE G3 Long range
corridor Lens
Coverage
15 m and 25 m 100o
Variable Mounting Height
2.1 m to 2.7 m
Intruder Detection Method
Combined PIR & Microwave
with Anti-CloakTM Technology
Anti-Masking Method
Active IR
Trouble Indication Visual & separate AM/trouble
relay
RFI Immunity
30 V/m from 10MHz to 1GHz
Operating Voltage 9-16 Vdc
Current Consumption @ 12 Vdc
12 mA typical, 39 mA
maximum with all 3 LEDs on
Alarm, Tamper & AM Contacts
Opto relays, N.C., 100mA,
24 Vdc
Alarm Time
2.2 sec. minimum
Optical Filtering for White Light Protection
Pigmented PIR sensor cover
Operating Temperature
-20o to 55oC
Storage Temperature
-20o to 60oC
Dimensions (HxWxD mm)
128 x 64 x 41
11
Detectors
Dualtech’s
Rokonet 360°
Features:
Anti-CloakTM Technology
‘Green’ setting - MW disabled during unset
Active IR Anti-Mask with separate relay
Built-in EOL resistors, ampere selectable
Cover and back tampers
Opto-relays for low current consumption and long
lifetime
Remote and local self test
Set and LED control inputs
Superior fluorescent interference rejection
LuNAR Green Line DT AM detectors are the
ultimate for professional 360 ceiling mount
installations, incorporating both Anti-Mask and
Anti-CloakTM Technologies (ACTTM ), adhering to
new environmentally friendly guidelines. Complies
with PD6662, EN50131-1 Grade 2 and TS50131- 2-4
requirements.
Order Code:
RK150DTIG3T
09/16
LuNAR Green Line DT AM
Grade 2
Technical Specifications:
Intruder detection
Method:
Coverage:
Combined PIR & Microwave
with Anti-Cloak™ Technology
13 m diameter at 4 m
mounting height
Detection zones:
60 zones; 30 Fresnel segments
arranged in 3 optical levels:
12 external, 12 middle and 6
internal segments
Anti-Masking method:
Active Infrared
Temperature:
Patented True
Compensation:
Temperature Compensation,
Microprocessor controlled
Trouble indication: Visual & separate AM / trouble
relay
RFI immunity:
30 V/m from 10MHz to 1GHz
Operating voltage: 9-16 Vdc
Current consumption
at 12Vdc:
12 mA typical, 39 mA
maximum with all 3 LEDs on
Alarm, Tamper:
and AM contacts: Opto relays, N.C., 100 mA,
24 Vdc
Alarm time:
2.2 sec. minimum
Optical filtering for white
light protection:
Pigmented PIR sensor cover
Operating temperature:
-20° to 55° C
Storage temperature:
-20° to 60° C
Dimensions:
(Diameter x Height) 135 mm x 27 mm
Maximum recommended
installation height: 4 m
EN50131:
Grade 2
12
Detectors
Sequential Confirmation Detectors
Pyronix TMD-15
Features:
15 m Volumetric PIRs
1-15 m Adjustable Microwave
Ability to operate as TMD (Two
Movement Detectors) or TriCover®
Interdigitated fields of view (Patent pending)
Ability to detect masking of either PIR or
Microwave
Anti Block technology (patent pending)
4 LED indications
Remote LED Enable
Low Voltage Fault Detect
The TMD 15® is a unique product boasting
2 nonoverlapping detectors; a PIR and a dual
technology in 1 robust housing. Based on Pyronix’
tried and tested patented technologies which has
been proven over the last 20 years coupled with
innovative features, the TMD 15® is ideal for use on
new systems or for retro fits upgrading to PD 6662 /
EN 50131-1 Grade 3 & TS 50131-2-4.
Order Code:
TMD-15
09/16
Pyronix Grade 3 DualTec
Sequential Confirmation
Detector 15 m
Technical Specifications:
Electrical
Operating Voltage 9-16 V DC (12 V nominal)
Current Consumption
- No Alarm State
24 mA
Current Consumption - Alarm State
28 mA
Relay
Solid State
Relay Output
50 mA, 60V DC protected
Tamper Switch
50 mA, 12V max
RFI Immunity to Continuous Wave (CW) 802000 MHz 75 V/m
RFI Immunity to Amplitude / Pulse Modulation
(AM / PM)
80-2000MHz
25 V/m
DTI approved frequencies
10.680, 10.687, 10.695GHz
FCC approved frequencies
10.515,10.525 10.535GHz
PTT approved frequencies
9.87, 9.90, 9.91 GHz
Alarm period of
2.5 secs
Detection Speed
0.2 - 3 m/s
Operating Temperature
-30°C to + 70°C
White Light Filter
2500 Lux
Optics
Sealed
Lens
Fresnel Array ‘Grooves in’
infrared
Protection
Ultraviolet Light Filter
Optimum Coverage Height
1.8-2.4 m
13
Detectors
Sequential Confirmation Detectors
IWISE QUADSEQ G3
Features:
Two PIR detectors in a single housing with
separate alarm outputs
Two non-overlapping coverage patterns
Coverage 12 m
Active IR Anti-Mask
Built-in Triple EOL resistors, jumper selectable
EN50131 Grade 3 compliant
Technical Specifications:
The Iwise QUADSEQ G3 non-overlapping coverage
patterns and two independent alarm outputs.
Iwise QUADSEQ G3 is designed to meet
ACPO DD243:2004 requirements for sequential
confirmation, and also meet PD6662, EN 50131-1
and TS50131-2-2 Grade 3 requirements.
Built-in Triple EOL resistors simplify installation, and
active IR anti-masking provides reliable detection of
masking attempts.
Order Code:
RK800QST
09/16
Risco Iwise Grade 3
sequential confirmation PIR
Coverage
12 m
Variable mounting height
2.1 m to 2.7 m
Intruder detection method
Two PIR sensors with separate
Digital Signal Processing
and relay outputs
Fault indication
Active infrared
RFI Immunity
Separate AM / Fault relay
RFI Immunity
30 V/m from 10MHz to 1 GHz
Operating voltage 9-16 VDC
Current consumption at
12 VDC 12 mA typical, 39 mA
with all 3 LEDs on
Alarm, Tamper and AM contacts
Opto-relays, N.C., 100 mA,
24 VDC
Alarm time
2.2 sec. minimum
Optical filtering for white light protection
Pigmented PIR sensor cover
Operating temperature
-20° to 55° C
Storage temperature
-20° to 60° C
Dimensions (H x W x D)
128 x 64 x 47 mm
14
Detectors
Passive Infra-Red
EV100PI
Features:
7 curtains of protection
12 m coverage
ASIC with “4” processing providing improved
detection and false alarm immunity
Additional Bi-curtain processing for harsh
environments
Precision “Gliding Focus Curtain” mirror
True range control (Autofocus) for stable
performance in all sizes of rooms up to 12 m
Remote enable/disable of walk test LED
Precision “Guilding Focus Curtain” mirrors
Sealed 4D/Bi-curtain processing
The EV100 series is ideally suited to small room
applications featuring solid curtains of detection,
range control, selectable bi-curtain processing for
harsh environments, sealed optics, “4D” signal
processing from a custom ASIC.
The EV100 has been designed specially for
Residential / short range commercial applications.
Details such as plug-in electronics allow rapid wiring
while the Gliding Focus Curtains ensure that you
have simple commissioning with perfect detection
every time, without the need for time consuming
alignment.
Order Code:
EV100PI
09/16
Step & Gliding Focus
Multi Curtain Mirror optics
Passive Infra Red Detector,
wide angle (86o with 5
curtains) selectable range
10 m or 6 m, NC relay, Pet
Immune version
Technical Specifications:
Detection range:
10 m
Undercrawl protection:
Yes
Detection range selection:
10 m or 6 m
Coverage field of view:
86° with 5 curtains
Coverage pattern selection:
Undercrawl blinder
Mounting height:
1.8 to 3.0 m
Power supply:
9 to 15 VDC
Current consumption (nom):
4.5 mA
Alarm relay (voltage free):
NC when energised
Tamper relay (voltage free):
NC when cover closed
Remote control lines:
Walk test
Alarm memory:
No
PIR process mode: Standard / Bi-curtain
Dimensions (W x H x D):
51 x 98 x 47 mm
Ambient conditions: -10 to +55°C; 95% relative
humidity
Pry-off tamper:
ST400 (optional)
EN50131-2-2:
Grade 2
15
Detectors
Passive Infra-Red
IS312
Features:
Digital processing for improved catch and false
alarm protection
Shock algorithm to reduce false alarms
Cannot be compromised by a magnet
Dip switches for easy setting of parameters
10 min. walk test after start-up or trigger
Large wiring channel on back to allow surface
wiring
The IS215TCE is an entry level passive infrared motion
sensor. It is fully featured with dual slope temperature
compensation, shock algorithm and digital signal
processing. This sensor is designed to fully comply with
EN50131-1 and TS50131-2-2 Grade 2, Class II.
Dip switch setting, a large wiring channel and mounting
flexibility make the IS215TCE easy to install.
Compromising the IS215TCE is inhibited by the lookDown zones, tamper switch, sabotage-resistant lens
design and the magnet-proof relay.
All these factors make the IS215TCE an ideal sensor for
residential and light commercial applications.
Order Code:
IS312
09/16
PIR pet immune motion
sensor 12 x 17m
Technical Specifications:
Detection method
Range
Detection zones
Dual element passive infrared
12 x 12 m
44 long range, 14
intermediate, 8 lower and 4
look-down
PIR sensitivity
Low (3-5 steps) and High (1-3
steps)
LED enable
By dipswitch
Mounting height
2.3 to 2.7 m
Power requirements 8.5 - 15.4 Vdc, 16 mA @
12 Vdc
Alarm relay
Form A (NC) / 30 [email protected] Vdc,
max.40 Ohm protective
resistor
Tamper switch
30 mA @ 24 Vdc
Operating temperature
-10oC to +55oC
Temperature compensation
Advanced dual slope
Relative humidity
5% - 95% non condensing
RF Immunity
30 V/m from 10 to 1000 MHz
White Light Immunity
Better than 6500 Lux
Dimensions
86 x 60 x 38 mm. (HxWxD)
Weight
67 g.
16
Detectors
Passive Infra-Red
iWISE® QUAD AM G3
Features:
Active IR Anti-Mask with separate relay
Built-in EOL resistors, jumper selectable
Wall and Cover Tampers
Opto-relays for low current consumption and
defeating magnets
Set and LED control inputs
3 LED walk test indication
The iWISE® QUAD AM G3 is designed for high-risk
installations. Two independent dual element PIR
sensors and digital processing channels provide the
highest level of catch performance and false alarm
immunity. Anti-Masking is achieved by an Active
Infrared channel, which is located behind the lens
to protect against covering or spraying of the lens–
even with lacquer.
Technical Specifications:
15 m (50’) 98°, 4 Vertical
levels and creep zone
Variable mounting height
2.1 m to 3.3 m
Intruder detection method
Two dual-element PIR sensors
with separate Digital Signal
The iWISE® QUAD AM G3 complies with PD6662,
Processing
EN50131-1, TS 50131-2-2 Grade 3 requirements and Anti-Masking method
includes built-in EOL resistors for easier installation.
Active infrared
iWISE QUAD AM G3 has an improved lens design
Trouble indication
Visual & separate AM / trouble
and Intelligent Digital Signal Processing methods
relay
that automatically adjust the alarm threshold and
RFI Immunity
30 V/m from 10MHz to 1 GHz
pulse count verification according to the actual event Operating voltage 9-16 VDC
occurring.
Current consumption at
12 VDC 12mA typical, 37mA
with all 3 LEDs on
Order Code:
Alarm, Tamper and AM contacts
Opto-relays, N.C., 100mA,
RK800Q0G3
Risco Iwise Grade 3 15 m
24VDC
PIR
Alarm time
2.2 sec. minimum
Optical filtering for white light protection
Pigmented PIR sensor cover
Operating temperature
-20° to 55° C
Storage temperature -20° to 60° C
Dimensions
128 x 64 x 46 mm
09/16
Coverage
17
Detectors
Passive Infra-Red
IS3016
Features:
Global compliance: meets many of the world
motion sensor standards Including the European
TS 50131-2-2 Grade 2, Class II
Selectable sensitivity: 4 settings to adapt to the
environment
Large wiring channel on back to allow surface
wiring
Patented look-down mirror provides optimum
detection directly beneath the sensor
Bug guard prevents insects to access the
sensor optics which reduces the chance of false
activation
Honeywell’s new IS2500 series consists of a
complete range of easy-to-install motion sensors
featuring reliable detection. The design of the entire
IS2500 series is sleek and attractive; all sensors
share the same family look.
The IS2560 sensor has an improved detection
performance and false alarm immunity to maximise
reliability.
Technical Specifications:
Detection method
Range passive
Dual element passive infrared
18 m x 26 m
(17 x 21 m in TS50131-2-2
and T014 installations)
PIR sensitivity
Lowest (3-5 steps), Low (2-4
steps), Medium (1-3 Steps and
high (1-2 steps)
Mounting height
2.3 m to 2.7 m
Power requirements 8.5-15.4 Vdc, 17 mA @ 12 Vdc
Alarm relay
Form A / 30 mA @24 Vdc,
Max. 40 Ohm protective
resistor
Tamper switch
30 mA @24 Vdc
Operating temperature
-10° to + 55°C
Temperature compensation
Advanced dual scope
Relative humidity
5% - 95% non condensing
RF Immunity
30 V/m from 10 to 1000 MHz
WLI
More than 6500 Lux
Dimensions
112 x 60 x 40 mm (H x W x D)
Weight
87gr
Includes
Mounting Hardware, Lens
masking, look down mask
Order Code:
IS3016
09/16
Honeywell PIR motion
sensor 16 x 22 m
18
Detectors
Passive Infra-Red
Tower 10AM
Features:
Vandal-resistant design - enabled by patented
V-Slot® Technology
Superior range and coverage area 25 m x 30 m /
90°
Market-leading black mirror optics provide
exceptionally high detection sensitivity and
immunity to false alarms
Easy installation - with adjustment-free height
range of 1.5 4 m
Unprecedented, complete anti-masking
protection
Full compliance with EN 50131 Grade 3 standards
The TOWER-10AM (PIR) industrial intrusion detector
from Visonic employs several revolutionary patented
technologies along with ground-breaking design and
construction.
They introduce unprecedented detection sensitivity
with an extremely large coverage area, antivandalism and virtually undefeatable anti-masking
capabilities – creating the ideal solution for large
industrial, commercial, institutional and government
sites, including museums, schools, hospitals,
stores, and transportation stations.
Technical Specifications:
Operating voltage 8 – 16 VDC
Standby current drain
12 mA (TOWER-10AM),
Alarm & trouble output:
Solid state relay, up to 100 mA,
-30 ON resistance
RFI protection
> 20 V/m (up to 2000 MHz)
Adjustable sensitivity 1 or 2 True Motion
Recognition events (TMR)
Operating temperature
-20°C to 55°C
Dimensions (HxWxD)
160 x 77 x 47 mm
Mounting height
1.5 - 4m no adjustment needed
Mounting accessories
BR-1, BR-2 and BR-3 brackets
Compliance Grade 3 EN 50131-2-2 (10AM),
EN 50131- 2-4 (12AM) (Eu
rope)
Order Code:
0-101183
09/16
Visonic Tower 10 Grade 3
25 m PIR with anti mask
19
Detectors
Passive Infra-Red
IR8M & IRPI8M
Features:
The IR8M & IRPI8M sensors mount virtually
anywhere – on walls, in corners or on ceilings
The two different lenses supplied with the
IRPI8M (Pet immune and high security) combined
with four levels of sensitivity which can be
adjusted by a switch, make it perfect for a wide
range of installations.
Compliant with EN50131 rev. 2008
Protected PCB for PI version.
The IR8M & IRPI8M are the new universal wireless
infrared sensors from Honeywell. These PIRs have
all the benefits of our existing range of Infrared
sensors and wireless peripherals.
Features of the IR8M include, compliance to TS
EN50131-2-2 Grade 2, Class II, providing exceptional
detection capabilities.
Features of the IRPI8M include selectable immunity
for animals weighing up to 36Kg, compliance to TS
EN50131-2-2 Grade 2, Class II, providing exceptional
detection capabilities.
Order Codes:
IR8M
IRPI8M
09/16
Universal Wireless Passive
Infra Red Detector
Universal Wireless Passive
Infra Red Detector including
pet immunity up to 36 Kg
Technical Specifications:
Detection range
11 x 12 m (at 2,30 m mounting
height) Look-down pattern for
Hi-Security applications
Pet Immunity (IRPI8M)
Switch selectable pet
immunity 0, 18 or 36 Kg
Tamper Switch
Front cover and back
White light immunity >6500 lux
Sensitivity & Pulse count
Switch selectable – Lowest,
Low, Medium, High
LED
Switch enabled Indicates
detection and transmission
(different timing)
Operating temperature
-10oC to 55oC
Storage temperature
-20oC to 70oC
Dimensions
11, 2 x 6 x 4 cm
Weight without battery
84 g
Includes (IR8M)
Lens masking, Battery
Includes (IRPI8M) Lens masking (PI and
Hi-security) Lookdown mask
for pet immune applications
(neoprene rubber) High
Security lens
Battery One 3 V CR123 lithium
Battery life
> 4, 5 years (> 3 years on
Galaxy or Vista radio modules)
Radio
Dual-protocols: V2 GY and
Alpha, FM narrow band,
868 MHz frequency, 2000 m
range in open field,
Supervision
Compatibility
Galaxy Radio module: RF-Portal
20
Detectors
Passive Infra-Red
EV669 - Short Range
Features:
360° coverage
Full undercrawl detection
20 m range (diameter)
2 x pyros; 2 x mirrors; 2 x ASICs; 2 x performance
18 unique gliding focus curtains
Precision mirror optics
Latest generation ‘4D’ signal processing providing
increased environmental stability with enhanced
detection capability
Electronic coverage pattern selection
Alarm memory as standard
Selectable control logic for alarm memory and
walk test LED
With 18 curtains the EV669 offers a maximum
detection capability throughout the protected area
including full undercrawl detection.
In order to ensure the highest performance, the
EV669 incorporates 2 x pyros, 2 x ACIS,s and 2 x the
decision power providing the installer/user with 2 x
the performance.
Technical Specifications:
Supply voltage:
8 - 15 Vdc; Max. ripple 2 V
peak-to-peak at 12 V dc
Current consumption: Normal operation 6 mA (EV
669) In alarm, LED on 11 mA
max.
Outputs:
Alarm:
NC 100 mA at 28 Vdc.
Voltage free relay
Tamper:
100 mA at 28 Vdc
Mounting height:
2.5 to 5.0 m
Coverage:
10 m radius
Ambient conditions: -18° to +55°C; Max 93%
relative humidity
IP rating:
IP301
Dimensions:
Ø 138 x 66 mm
EN50131:
Grade 2
Order Code:
616.013.019
09/16
Aritech EV669 20m
diameter Radial PIR. Ceiling
Mount
21
Detectors
Vibration Sensors
Risco Grade 3 shock sensor
Features:
Digital Microprocessor with Intelligent Digital
Signal Processing
Gross Attack detection
Intelligent Digital Signal processing –
differentiates between na caused vibrations and
cuts out frequencies that cannot be caused by an
illegal entry attempt
Ideal for windows, doors, walls and roofs
Encapsulated bi-morph piezo electric sensor
Rear Tamper
ShockTec™ is a digital shock detector providing
reliable 24-hour perimeter protection. A break-in is
detected as soon as the intruder attempts to force,
smash, drill or saw through the protected window,
door, wall or roof.
ShockTec™ employs an advanced digital
microprocessor to analyze the vibration signal
received from the piezo electric sensor.
A unique feature of ShockTec™ 600S is its digital
sampling of the signal simultaneously in two
separate channels, each channel amplified at a
different gain. This provides an extremely wide
dynamic range of the sampled signal, enabling
precise measurement and analysis of the shock
signal.
Order Codes:
RK600S0G3
KITRK600G3
09/16
Risco Shocktec white
sensor
Risco Shocktec Brown
sensor
Technical Specifications:
Supply voltage:
9 V-16 V DC
Current consumption (typical)
12.5 mA
Operational temperature:
-20°C to 60°C
Maximum humidity:
95% non-condensing
Sensitivity setting:
Dual stage potentiometer
Tri-color LED indicator: Orange-over-sensitive,
green: alarm & correct
calibration, red: undersensitive
Contact ratings:
Alarm relay:
100 mA at 24 VDC, NC
Tamper relay:
500 mA at 24 VDC, NC
Alarm Time:
2.5 seconds
Latching modes:
Any or first to latch
operation modes
Max No. of units on AnyLatch loop:
80
Max no of unites on 1st to Latch loop:
10
False alarm protection: Digital microprocessor signal
processing and noise
reduction with maximum
ground plane
Electrostatic discharge: No false alarms up to 8 kV
RF immunity:
40 V/m from 80 MHz to
1GHz
Enclosure material:
Flame retardant ABS
Enclosure dimensions: 25 x 28 x 95 mm
22
Detectors
Vibration Sensors
Elmdene 5169 Safe Limpet with Delay
Features:
Internal Heat Detector
High Security
Simple Installation and Calibration
High Rejection of False Triggers
The Limpet Set is designed for the protection of
safes, filing cabinets, fruit machines etc. and may be
fitted to any article or piece of equipment that has
a ferrous exterior. The selective vibration detector
is designed to trigger an alarm if any attempt is
made to gain access to the protected equipment by
hammering, drilling, chiselling etc. The heat detector
contact opens at a nominal temperature of 60° and
gives protection against attacks by thermal cutting
techniques.
The keep reed switch, which is held in the closed
circuit position by the keep magnet, becomes open
circuit when the limpet is removed from the keep,
and thus trigger the alarm if any attempt is made to
remove the limpet from the keep. In this sense it
acts as a proximity switch. The second reed switch
is opened by the presence of an external magnet.
This eliminates the possibility of an external
magnet being used to override the keep magnet
reed switch.
09/16
Technical Specifications:
Dimensions:
Weight:
120H x 95W x 35D mm
(Limpet)
130 H x 105W x 30D mm
(Keep)
Limpet - 356 g
Keep - 136 g
Order Code:
616.013.028
Safe Limpet with delay
23
Detectors
Vibration Sensors
SC100 Series Seismic Sensors
Features:
Universal (ATM& vault)
Drilling shield (standard)
Remote sensitivity reduction input
Multi compatible mounting plate fits on pre-fab
holes product
Integrated EOL resistors
Integrated temperature alarm
Diagnostic LED
Selectable sensitivity
EN50131-1 Security Grade 3, Environmental
Class II
SC100 Seismic sensors range is designed to detect
selected vibrations from burglary or intrusion
attempt to high value storage units.
The SC100 model is a universal seismic sensor
which can be used such as Vaults, Doors, fixed
ATMs, Safes and other solid structure objects.
ATMs
Night Deposite Safes
Strong Room Vaults
Modular Vaults
Free Standing Safes
Hatches
Gates
Chests
Lobby-ATMs
Filing Cabinates
Containers
Vending machines
Ticket machines
09/16
SC100
X
X
X
X
X
X
X
X
X
Dimensions:
Weight:
The SC105 is a dedicated version for mini-ATMs
or vending machines that usually work in noisy
environment. It offers the optimal sensitivity/false
alarm immunity ratio for the free-standing objects
that the SC105 will protect.
Applications
Vault Doors
Technical Specifications:
SC105
Order Codes:
SC105
SC100
SC110
SC111
SC112
SC113
SC114
SC115
SC116
SC117
X
X
X
X
X
X
X
120H x 95W x 35D mm
(Limpet)
130H x 105W x 30D mm
(Keep)
Limpet - 356 g
Keep - 136 g
SC118
Seismic sensor
Seismic sensor
Mounting plate
Movable mounting kit
Keyhole protection kit
Internal test transmitter
(NSL order only)
Armoured cable kit
External test transmitter
(NSL order only)
Wall recess mounting kit
(NSL order only)
Floor recess mounting kit
(NSL order only)
Spacer for SC112 Keyhole
mounting kit.
24
External Lighting
This chapter contains information about our External Lighting
Introduction
GJD Digi Zone
09/16
1
External Lighting
Introduction
In the field of physical security, security lighting is
often used as a preventive and corrective measure
against intrusions or other criminal activity on a
physical piece of property. Security lighting may
be provided to aid in the detection of intruders, to
deter intruders, or in some cases simply to increase
the feeling of safety. Lighting is integral to crime
prevention through environmental design.
Security lighting can be used in residential,
commercial, industrial and institutional properties.
Some examples of security lighting include
floodlights and low pressure sodium vapour lights.
Most lights intended to be left on all night are highintensity discharge lamps as these have good energy
efficiency, thus reducing the cost of running a lamp
for such long periods.
09/16
Other lights may be activated by sensors such as
passive infrared sensors (PIRs), turning on only
when a person (or other mammal) approaches. PIR
activated lamps will usually be incandescent bulbs
so that they can activate instantly; energy saving is
less important since they will not be on all the time.
PIR sensor activation can increase both the deterrent
effect (since the intruder knows that he has been
detected) and the detection effect (since a person
will be attracted to the sudden increase in light).
Some PIR units can be set up to sound a chime as
well as turn on the light. Most modern units have a
photocell so that they only turn on when it is dark.
2
External Lighting
External Lighting Control
GJD DygiZone External Lighting
Features:
!
User-friendly control panel
Modern LCD display
$
"
^'$
$]]]]"
The Advanced Multi-function, 4 zone, security
lighting controller & enunciator, that saves power,
minimises light pollution and enhances security.
Technical Specifications:
_'
The new advanced, feature rich DygiZone Controller
provides intelligent security lighting control which
enhances security, saves energy and minimises light Mounting
pollution with features such as !"!
of security lighting via a user-friendly control
panel and modern LCD display.
"# the activation, timing and duration of the lighting
to minimise energy consumption and light
pollution.
#"
$ for each zone.
'<=?
DygiZone indicates which Zone has been activated
by either an audible beep or a 10 second prerecordable voice message - and the Zone indicator
is illuminated on the control panel.
$
" lighting to be automatically switched on & off
at pre-set periods for a pre-set time-ideal for when
a building or premises are unoccupied.
#
"$
locations at any time.
[#
'$
$
]]]]"
switched as required.
09/16
Temperature
? ‚$$#
100
`$"]]]]
of lighting can be controlled
and programmed across the 4
Zones
For indoor use only. Mount in
a clean dry location. Can be
fitted to a standard single or
double flush backbox
-10o{oC
|!}~'€}~']
( D ) mm
|ƒ?„]
#
mA triggered with message
playback
|†]‡^[ˆ]<‰Š‚‚
Order Codes:
GJD910
GJD332
GJD040
8162N
GJD 4 zone LCD Dygizone
controller
GJD Mini Opal 30 m sensor
GJD 4 Zone Expansion unit
with 1amp switch mode psu
Enclose 400 w halogen fitting
3
Visonic
This chapter contains information about our range of Visonic Equipment
Introduction
Panels
PM10
PM30
PM360 SmartHome
PM33
Peripherals
Service Spares
Replacement Batteries
10/16
1
Visonic
Visonic Introduction
PowerG® is Visonic’s patent-pending, revolutionary
wireless technology for intrusion alarm systems.
PowerG introduces a new era in the alarm systems
industry, literally redefining wireless intrusion
security and reliability. It fully answers the most
demanding needs and requirements facing the
security industry today, as well as the challenges of
tomorrow.
Combining reliability, performance and an advanced
feature set, Visonic’s PowerMaster G intrusion alarm
systems lead the wireless security market. Using
Visonic’s revolutionary PowerG wireless network
technology (patent pending), the PowerMaster family
of products comprehensively addresses the needs
of all residential premises, installers and central
monitoring stations alike.
PowerG technology highlights:
‹Œ#
no lost alarm messages
_Œ‹‘#$$‚$
‚$}‹‚‚~#
frequency blocking and interference from wireless
home appliances
?##$ $‰‹"
[?_## eliminates message collisions
^‚Œ|#$$$" analysis tools and digital attacks
Green, Energy-saving System
[Œ##$$ communication eliminates unnecessary retransmissions.
[#$Œ#•
#""$$
_$$$
adaptive transmission power that is determined
according to the distance from the panel and level
"‰‹"
PowerMaster-10 G2
The PowerMaster-10 G2 is an ultra-compact,
wireless alarm system suitable for advanced
applications and heavy duty operations. It has a
superior range, prolonged battery life and unmatched
wireless robustness. Moreover, it provides
outstanding full two-way wireless functionality with
all peripherals.
PowerMaster-30 G2
The PowerMaster-30 G2 Professional wireless
security and safety system supports advanced
security applications. Suitable for the heavy duty
operation required in mid to high-end residential
premises.
PowerMaster-360
PowerMaster-360 is a security, safety and smart
home gateway. It is ideal for clients wishing to
Œ‹–<
security and safety sensors. Combined with a
connected home web platform and application, this
New Toolset for Faster and Easier Installation
gateway allows you to control your home from a
‚$
$" single point. This latest innovative solution leverages
enrolment procedures.
our 30 years of proven security leadership and
""$“‡ award-winning technologies.
hardware switches and no need to re-open
the peripherals once closed.
PowerMaster-33
"$
The Powermaster-33 G2 is a distributed wireless
configuration of the devices collectively.
security, safety and control system. It is suitable
ƒ
‘#
for SME usage customers who want a concealed
device Enables the installer to choose the
alarm system. It provides outstanding wireless
optimal location without having to walk to
functionality with all peripherals.
the panel during mounting.
"‰‹”‘#
based on the previous 24 hours’ statistics and ondemand bi directional measurements, displaying
immediate problems and enabling verification
of the installation during house setup.
10/16
2
Visonic
PowerMaster Panels
PowerMaster 10/30
Features:
‡^—‚#
Combining reliability, performance and an advanced
feature set, Visonic’s PowerMaster intrusion alarm
systems lead the wireless security market. Using
Visonic’s revolutionary PowerG wireless network
technology (patent pending), the PowerMaster
family of products comprehensively addresses the
needs of residential and commercial premises,
installers and central monitoring stations alike.
^
‘”$"
devices
""$
#"Œ‡
re-open device covers or remember complex
hardware switch configurations
?
”
‘#Œ‡$$$
during installation
˜Œ‡"$
_Œ‹‘#$$‚$
‚$}‹‚‚~#
frequency blocking and interference from
wireless appliances
Two-way communication ensures that no alarm
messages are lost
?##™
when communicating with the PowerMater panel
Extended transmission range of up to 2000 m
(line-of-sight)* - Enables reliable communication
with remote devices, even in difficult conditions
or complicated infrastructures
Order Codes:
Improving Service and Reducing Costs with
—‹
Intrusion alarm systems must constantly overcome
challenges to maintain a high level of security,
including meeting stringent regulatory requirements
and lowering operational expenses. The
PowerMaster family provides wireless robustness
and reliability closer than ever to that of wired
systems. This eliminates the expense of installing
wires and associated damage to the installation
site. With a superior range, a long battery life and
unmatched ease of installation, PowerMaster
systems meet these challenges head-on; and excels
in advanced applications and heavy duty operation in
both residential and commercial settings.
10/16
]Œ|]!]
0-103474
_Œ|]}ˆŒ]š‡›~
?[`œœ_?Š‚|†|
_Œ]}ˆŒ]š‡›~
?[`œœ_?Š‚|†|
3
Visonic
PowerMaster Panels
Robustness and Reliability
_Œ‹‘#$$‚$
‚$}‹‚‚#
frequency blocking and interference from wireless
appliances
[Œ#
messages are lost
[?_##
eliminates message collisions
?##™
when communicating with the PowerMater panel
^'"$ 2000 m (line-of-sight)* Enables reliable
communication with remote devices, even in
difficult conditions or complicated infrastructures
^‚Œ|"
maximum protection
_#
maintenance of tens of thousands of alarm
systems via IP from the monitoring provider›s
technical centre
Faster and Easier Installation
^
"Œ”
^
‘”$" devices
"$#" the basic parameters of any device
""$
#"Œ‡
to re-open device covers or remember complex
hardware switch configurations
?
”
‘#Œ‡$$$
during installation
˜Œ‡"$
Total Control from the Central Monitoring Station
""$$
‰#$"” Green, Energy-saving System
‡#Œ
an installer present onsite
""‰‹ ˜
#"$
link quality
energy
ƒ"" ^#Œ$
assessment of best response and to avoid false
consumption
dispatches
Feature
–
Proximity Tags
Sirens
œ#"
œ#$
Users
Wired Siren
–
˜‹‚
Wired Extender
Voice (two-way, prompts)
Partitions
Battery Backup
Power Supply
Communication
Repeaters
10/16
PowerMaster-10
30

4
PowerMaster-30
64
32




‡
1
]
‡
32
32
!
›
1 or 2
1000
›
(1 PGM output, 2 additional hardwired
||
'~
Optional
3 common areas
12hr
Internal or external
žŒ‚[‡
optional GSM/GPRS internal module
‡
3
12hr
Internal or external
žŒ‚[‡
optional GSM/GPRS internal
module
4
4
4
Visonic
PowerMaster Panels
PowerMaster 360 SmartHome
‹š
Single box solution, security and homeautomation
‚#‰‹”Œ<Ÿ
– —‹—"Œ
Cellular and IP communication
Compliment a cloud based smart home solution
and application
PowerMaster-360 Benefits:
#"¡‚¢š‚#‚"#
and Smart home
Intelligent solution which conditioned to your day
and needs
Providing a peace of mind by enrolling your home
to enhancing your safety
PowerMaster-360 is a security, safety and smart
home gateway. It is ideal for clients wishing to
Œ‹–<
security and safety sensors. Combined with a
connected home web platform and application, this
gateway allows you to control your home from a
single point. This latest innovative solution leverages
our 30 years of proven security leadership and
award-winning technologies.
Feature
–
Proximity Tags
Sirens
œ#"
œ#$
Users
Wired Siren
–
˜‹‚
Wired Extender
Voice (two-way, prompts)
Partitions
Battery Backup
Power Supply
Communication
Repeaters
10/16
PowerMaster-360
16

2
How it works
Intelligent cloud-based platform allows you to
condition your home to behave based on events.
›! €$"#
the Mobile app, which provide access and control of
your home appliances, security and safety devices
#"#
#›
and pre-configure appliance behaviour to time or
events.
Order Code:
0-103107
_Œˆ]}ˆŒ]š‡›~
?[`œœ—[_?Š‚|†|

4

‡
‡
]
‡
‡
3
4hr
External
žŒ‚[‡
optional GSM/GPRS
internal module
1
Visonic
Peripherals
‚
Item
Order Codes
PM30 Ethernet Module
Š^‰˜—‡œ`œœ—[
†Œ|]
PIRCAM
PIR Camera
0-103203
IP Camera
Sercomm IP Camera
‰|ƒŒ`œ
Z wave switch
^$–Œ‚
‡|€Œ
Netgear gateway
‚<|]]|Œ|[`œ‚
1 Metre Patch lead Cat 5e
374002
2 Metre Patch lead Cat 5e
374003
3 Metre Patch lead Cat 5e
610.001.041
DC Extension 2.1 mm 3.0 m for IP Cameras
]|†]!
]|†]
DC Extension 2.1 mm 5.0 m for IP Cameras
]|†]ˆ
DC Extension 2.1 mm 10 m for IP Cameras
10/16
240 v Extension Leads 4 way
‡˜^˜
TP-Link AV600
[˜Œ!]|]œ—[Œ$
‚]|
6
Visonic
PowerMaster Panels
_Œ<<Œ
?
‹š
PowerMaster-33 G2 is a distributed wireless
security, safety and control system. It is suitable for
SME usage and for residential customers who want
a concealed alarm system. It provides outstanding
wireless functionality with all peripherals
_Œ<‹‘#$$
‚$‚$}‹‚‚~#"
Œ##[?_”
for streamlined communication and improved
channel efficiency. With a huge transmission range
of 2000 m line of sight*, it covers significantly
larger premises than traditional systems, without
repeaters
New Toolset for Faster and Easier Installation
‚$
simplifies enrolment procedures.
""”#$
$“‡Œ
open the peripherals once closed.
"$
configuration of the devices collectively.
ƒ
‘#
“^
optimal location without having to walk to the
panel during installation.
"‰‹”‘#
based on the previous 24 hours’ statistics and
on-demand bi-directional measurements,
displaying immediate problems and enabling
verification of the installation during house setup.
10/16
?
$
"
sight, controlled by wireless devices
|]š
`$ˆ!
`$|]œŒ]<”#$$”#"

sirens, 4 repeaters
Optional GSM/GPRS/IP modules
Extensive range of PowerG peripherals for every
application
Remote configuration and diagnostics with
system status indications
""
keypad
‚‡Œ˜”
"
all alarms
‚$$$|”
hundreds of thousands of doors
Order Codes:
0-103113
]Œ|]
_Œ?[`œŒœ—[
Commercial (End Station
#$$~`œ
Commercial (End Station
type panel) RoI
PM33 commercial kit
7
Visonic
PowerMaster Panels
Technical Specifications:
‰‹”
<Œ‹‘#$$
Œ}?_~
‹‘#
}_~
!“!!ˆŒˆ††|Œ
†|†
Hopping frequencies
!]
^#$
^‚Œ|
‡
" ˆ!
`
!
ž”Œ$
#
!
”Œ$“€ƒ
|]]‡_!
”Œ$“†ˆƒ|]] ‡_
?
ˆˆ']|'!ˆ
Weight
1.44 kg
Power supply
Internal or external according to
local regulations
‰$" š‚——?
Scancom;
—š
‚——ƒ‡
‚[‡<‚_<‰‚—
Feature
–
Users
Proximity Tags
Pendants
œ#"
œ#$
Sirens
Wired Siren
–
˜‹‚
Wired Extender
Voice (two-way, prompts)
Partitions
Battery Backup
Power Supply
Communication
Repeaters
10/16
PowerMaster-33
64
!
32
|
32
32

›
1 or 2
1000
›}|<_$|
'~
Optional
3 + common areas
`$!
Internal or external
žŒ‚[‡
optional GSM/GPRS internal module
4

Visonic
Peripherals
_œ#$?
Item
Order Codes
KF-235 PG2
PowerG 2-way wireless 4-button keyfob, includes 3 V CR-2032
lithium battery
]Œ|]€!
KP-141 PG2
PowerG 2-way wireless keypad, with proximity reader, includes 3 V
‰|
#
0-102746
KP-160 PG2
PowerG 2-way wireless touch-screen keypad with proximity reader,
!'|ƒ”
#Œ
0-102747
KP-250 PG2
PowerG 2-way wireless keypad with proximity reader ncludes 4x
|ƒ”
#Œ
‹$
$
control of the system
Mini Tag 4
Mini Proximity tags, bag of 4, random colours
0-103222
˜?[”#$
}~`œ
PB-102 PG2
Twin-button Operated Hand-held PowerCode Wireless Transmitter
]Œ|]]†
œŒ]!†
PowerG Intrusion Detectors - Volumetric
Item
Order Codes
NEXT K9-85 PG2
<Œ#—‰| †]£$
$Œ}$”~ƒ‰|
battery
]Œ|]€†
NEXT PG2
PowerG 2-way wireless digital PIR detector, | †]£
'ƒ‰|
#
0-102740
TOWER-20AM PG2
PowerG 2-way wireless outdoor PIR motion mirror detector,
| †]£Œ”
]Œ|]ˆ|
]Œ|]†|
TOWER-32AM PG2 K9-40
PowerG 2-way wireless PIR motion mirror dual technology detector,
| †]£$Œ”
$Œ}$|”~ƒ‰|
#
10/16
†
Visonic
?
<—?Œ
Item
Order Codes
0-102741
MC-302 E PG2
PowerG 2-way wireless door/window contact with auxiliary input,
ƒ‰|
#Œ
0-102743
MC-302 E PG2 B
PowerG 2-way wireless door/window contact with auxiliary input,
ƒ‰|
#Œž
†Œ|]€††
MAG SPACERS 3mm BR
‚$"_Œ]_Œ]^
"Œž
†Œ|]€†
MAG SPACERS 3mm WH
‚$"_Œ]_Œ]^
"Œ
†Œ|]]ˆ
MAG SPACERS 7mm BR
‚$€"_Œ]_Œ]^
"Œž
†Œ|]]
MAG SPACERS 7mm BR
‚$€"_Œ]_Œ]^
"Œ
]Œ|]
GB-502 PG2
PowerG 2-way wireless accoustic glass-break detector, max.
ˆƒ‰|
#
0-102761
SD-304 PG2
<Œ#$”ƒ‰|
lithium battery - White
10/16
10
Visonic
‚"#?¥‚
<—?Œ
Item
Order Codes
SD-304 PG2 B
<Œ#$”ƒ‰|
lithium battery - Brown
0 -102766
MC-302V PG2 (868-0) white
PowerG 2-way wireless door/window contact slimline, includes 3 V
‰|
#Œ
]Œ|]ˆ!
MC-302V PG2 B (868-0) brown
PowerG 2-way wireless door/window contact slimline, includes 3 V
‰|
#Œž
]Œ|]†|
<‚"#?
Item
Order Codes
FLD-550 PG2
PowerG 2-way wireless flood detector with 30 sensor cable,
ƒ‰|
#
0-102763
GSD-441 PG2 UK
<Œ#ƒ‰|
#Œ`œ$
]Œ]]|
GSD-442 PG2
<¤#
'†ƒ
”
#
]Œ]]||
SMD-426 PG2
PowerG 2-way wireless photoelectric smoke detector, ceiling
}ž]~ƒ
‰|
#
]Œ]]|!
]Œ|]€ˆ
TMD-560 PG2
PowerG 2-way wireless temperature detector with up to four
$$}'""
'~ƒ‰|
#
10/16
11
Visonic
‚"#?¥‚
PowerG Siren
Item
Order Code
]Œ|]|
SR-720B PG2
<Œ#||]ž$Œ$
strobe light
Note: For PM10/PM30/PM33
0-103321
SR-720B PG2
<Œ#||]ž$
Note: For PM360 only
]Œ|]†]
RP-600 PG2 (868-0)
‰Œˆ]]<}ˆŒ]~‰$
10/16
12
Visonic
‚‚$¥ž
Spare parts
10/16
Item
Order Codes
PMASTER-360 panel
_ˆ]}ˆŒ]š‡›~?[`œ‚Š˜Š$#
0-103471
PMASTER-10
_‚[^‰Œ|]}ˆŒ]š‡›~?[`œ‡^˜
]Œ|]!|
PMASTER-30
_‚[^‰Œ]}ˆŒ]š‡›~?[`œ‡^˜
0-103473
GSM-350 PG2
Cellular communicator for PowerMaster-10, supports GPRS,
GSM and SMS, for high-speed reporting and two-way voice
$$‚— —‚——?
†Œ|]|ˆˆ
PSU PM360
[‰‹Š ?|]]Œ]ƒ| |†ˆ`œ
ˆ]Œ]€ˆ†
PSU PM10
[‰‹Š`œ_] †ƒ ]€˜`<›¦ˆ|
260-302321
ANTENNA GSM QUAD BAND
‡[^‡‡<‚_§`?ž‡?_‰<|€!`__¦‰ External antenna for GSM 300
††Œ]|]€
TP-Link AV600
[˜Œ!]|]œ—[Œ$
‚]|
EXPANDER BOARD
Expander Board for PowerMaster30, enables the addition for one
<_$
output and Speech Box interface
†Œ|]]€€
13
Visonic
Service Batteries
Batteries
10/16
Item
Order Codes
Battery Co
ž#””†ƒˆ'|ˆ'!€
[›Œ!|Œ‹|
Battery Keyfob
ž#˜Œ_ƒ]ž‰]
]Œ††|Œ
Battery Perif
ž#˜Œ_ƒ|‰|
]Œ††|Œ‡
Battery Pack Next Cam 5yr
ž#”˜Œ_'ƒ‰|€!]
|]Œ]†|
Battery Pack PM30
ž#”‡Œ_€ƒ|}ˆ'|ƒ~˜[[
|]Œ]ˆ†
Battery Pack PM10
ž#”‡—Œ_!ƒ |}!'|ƒ~$”
††Œ]|€|
Battery Pack Internal Siren
Battery Pack
œŒ]|€€
Battery KP160
ž#”|ƒ
[›Œ!|]ˆŒ‹
14
Galaxy Control Panels
This chapter contains information about our range of Galaxy Control Panels
Introduction
Galaxy® Flex
Galaxy Dimesion Series
Interfaces and Ancillaries
Galaxy RF Ancillaries
Galaxy PC Package
10/16
1
Honeywell Galaxy
Introduction
Flexible control panel range for small to medium
sized security installations
Honeywell’s Galaxy® Flex control panel series is a
fully integrated intruder and door control security
solution that brings a new level of ease and
flexibility to small to medium sized, Grade 2 security
systems. Galaxy Flex’s three feature rich panel
options are based on a modular design that allows
full customisation to meet specific needs.
Galaxy Dimension Series
The Galaxy Dimension series of security systems is
a fully integrated intrusion and door control security
solution for mid to large commercial security
installations. It offers a user-friendly system in a
cost-effective package that is fully compliant to
the PD6662:2010 and EN50131 standards. There is
now an innovative wireless capability available for
intruder functions with Galaxy Dimension that offers
high quality, reliable security solutions, with the
flexibility to meet the needs of every commercial
and industrial application.
Interfaces and ancillaries.
A wide range of galaxy modules allow expansion of
the Galaxy control panels, providing fully flexible and
customisable security solutions to meet customer
requirements. The Galaxy control panels are
supported by a common set of LCD keypads and
Keyprox’s, minimizing inventory required.
10/16
The Mark 8 LCD keypad and keyprox offers an
attractive alternative solution for installations where
style and appearance are important. In addition a
Colour graphical touch-screen keypad simplifies the
operation and helps to minimise operator errors.
Galaxy RF ancillaries
A full range of wireless sensors that offer varied
capabilities. The comprehensive range of wireless
peripherals and detection devices are compatible
with both Galaxy Dimension and G2 intruder alarm
panels and address all of the needs of an intrusion
system and more.
They include environmental protection and life
safety devices, and perimeter protection products
including glassbreak, seismic and shock sensors.
Some of our systems have a modular design and
different communications options, so you can tailor
them to your needs. You can choose from wired,
wireless or hybrid solutions.
Galaxy PC Package
User Management Suite (UMS) allows the end
user to remotely manage their installed systems or
provide simple windows based control of a system
locally.
2
Honeywell Galaxy
®
Galaxy Flex
Galaxy® Flex
Features:
Flexible expansion
Up to 100 wired or 88 wireless zones Up to 100
users Up to 98 wireless key fobs Protecting up to
8 groups
Door control
Up to 4 door controllers (DCMs) controlling up
to 8 doors.
Access event log records up to 1000 events
Compatible with most Wiegand readers
Galaxy Flex 20 is feature packed for small systems
up to 20 zones, Flex 50 delivers high flexibility for
small to mid size systems where ease of install
and functionality are important and Flex 100 offers a
highly competitive system for a greater number of
zones and functionality.
Based on the tried and trusted Galaxy® technology,
Flex is scalable and compatible with the Galaxy
Dimension control panel range so that installers
have a single, familiar range of panels to meet
the needs of the smallest to the largest security
installations. Plus with a common range of
peripherals both training and stock are minimised.
10/16
Up to 4 annual holiday schedules
Up to 4 weekly schedules available
3 User interfaces
TouchCenter, new MK8 and traditional MK7
keypads/proxes
Back up battery
Supports efficient, space saving 10Ah battery
design from Yuasa (REC10-12)
Resettable fuses (PTCs)
Integrated resettable fuses for Auxiliary power
supply and battery
Auto-detect function for faster installation
System automatically recognises when modules
are added/removed from system without the
need to leave engineering mode
One comprehensive range of wired and
wireless intrusion and environmental detectors
Full compliance with EN50131,
PD6662:2004/2010, DD243:2004,
BS8243:2010, Security Grade 2 compliant,
Environmental Class II
3
Honeywell Galaxy
®
Galaxy Flex
Galaxy® Flex features
Efficient Installation
Its ‘plug and play’ feature makes the panel easy to
install for any installer as remote peripherals are
detected automatically once the panel is
installed and powered up. Connections are clear
and unambiguous, reducing training requirements.
Bus wiring, using standard cable offers flexibility for
retrofitting and reuse of existing cabling. Offering
total flexibility, installers can now select their
preferred power connection from three options
depending on preference and installation type.
Easy programming
For installers new to Galaxy, programming couldn’t
be simpler using Galaxy Flex’s quick start guide and
intuitive menu based programming. Alternatively,
programming via PC can be completed in minutes
using its intuitive Windows programming interface
by either connecting a standard mini-USB cable
directly to the panel or remotely via Ethernet, GPRS
or phone line.
No limits wireless
Take the wireless route when aesthetics are
important or cabling is impractical or too expensive.
Galaxy Flex offers the flexibility of wired and
wireless in one system without compromising
the reliability of the system thanks to Honeywell’s
proven bi-directional radio and agile routing
technologies.
Flexible communication options
Multiple path communications options for alarm
signalling include GSM/GPRS, Ethernet and
standard telephone line for maximum flexibility and
customisation to ensure reliable signalling in any
situation.
Attractive user interfaces
A range of attractive user interfaces, including the
Galaxy TouchCenter, make end users’ lives easier
with clear on-screen guidance so that training
and ongoing support is minimised.
Extended control
An optional trigger module allows the Flex panel
to easily activate and control third party devices
such as communicators, CCTV, lighting and access
control systems without the need for an additional
controller.
One range fits all
Galaxy Flex allows installers to benefit from all the
features of the powerful Galaxy Dimension panel in
a fully compliant Grade 2 panel and with full
flexibility to meet the demands of small, 12 zone
installations right up to larger 100 zone installations.
Remote management
Galaxy Flex can be monitored from a central location
using Galaxy’s Remote Servicing Suite (RSS)
software. Using this software, installers can
provide customers with instant support as well as
saving time and money in unnecessary site visits.
Whether it is a routine inspection, scheduled
maintenance or even simply checking system
status, it can be done remotely from a fixed or
mobile location.
Order Code:
10/16
C006-S-36
Galaxy Flex 50 Metal Box
4
Honeywell Galaxy
®
Galaxy Flex
Zones on board (Max expansion)
Max wireless zones
Wireless transceiver/RF portal
Outputs—switched (with trigger module)
Trigger outputs—relay
Integrated PSU
Output current rating (EN50131 / Security Grade 2)
Keypads/Keyprox
Galaxy TouchCenter/ prox
Bus mounted prox readers
Door controllers (DCM)
DCM controlled doors
Users
Multi-users
7 day timer schedules (Autoset & Access)
Event log
Access log
Access control groups (user templates)
Speaker driver
Local communication interface
Groups/Areas
Part set per group
Silent set option
Links
RS485 databuses
SMS text
Library
Communication options
PSTN
Ethernet
GSM/GPRS
Audio options
Voice listen-in option
2-way voice option
FX050
12 (52) 40
8
2-22 (30)
0-1
1A
0.7A
4
1
4
4
8
50
Yes
4
500
500
10
Yes
USB
4
1
Yes
5
1
Yes
Yes
onboard
optional
optional
2 channels
2 speaker
channels
Mechanics
Dimensions (h x w x d)
Weight (excluding battery and in-box peripherals)
Approvals
10/16
5
Attractive user interfaces
A range of Touchscreen, LCD Keypad and Keyprox options
Compatible with Galaxy TouchCenter giving end users clear
and easy to view touchscreen graphical display
MK8 keypad offers a modern keypad and keyprox design
with all the familiarity and functionality of the MK7 keypad
Familiar MK7 keypad for installer programming across the
range Proximity function across all user interfaces allows
quick and secure set and unset without PIN code
Flexible power connections
Lighter and more efficient than a standard transformer
Expansion Options
Clip in module expansion slots
Allows total customisation depending
on security needs
Designed to host trigger and other new
modules
External Power Supply Units (PSUs)
Galaxy® Power Unit 2.75 A
Rated at 1.0 A
Reports AC, Battery, fuse and tamper via RS485
Galaxy® Power RIO 2.75 A
Rated at 1.0 A
Reports AC, Battery, fuse and tamper via RS485
Integrated RIO (8 inputs/4 outputs)
Proximity reader - MAX4
Galaxy® Power Unit 2.75 A
Complete door control in a single unit
Can be used as standalone or
integrated into the Galaxy® control
system
Connected on RS485 bus
10/16
Door Control Module (DCM)
Supports up to 4 door control modules
Each door control module has 2 Wiegand inputs allowing
management of 2 doors
Door access controlled by access templates and up to 4
weekly and/or annual holiday schedules
6
Flexible communication modules for alarm signalling and remote
servicing
Option of internal GPRS/GSM or Ethernet module
Supports additional Ethernet module in place of GSM/GPRs
Enhanced dual path signalling options:
1 Ethernet backed up by PSTN
2 GPRS backed up by GSM
3 GPRS backed up by PSTN
Wireless Options
4 PSTN backed up by GSM
Bi-directional wireless interface with full range of intrusion and
environmental detectors
868MHz frequency
Up to 8 wireless interface modules (RF portals)
Up to 88 wireless zones and up to 98 key fobs
Full bi-directional agile routing (patented technology)
Compatible with all Honeywell Alpha protocol sensors
Standard connectivity
USB enabled for direct connect to local PC
using USB cable (mini USB port)
Remote maintenance
Provides complete remote servicing capability
including off-line programming, real-time control and
diagnostic reporting
Programming upload and download
Event log and access log upload
Remote Routine Inspection (RRI)
Mimic panel for control functions
Online keypad support
Galaxy® RIO (Remote Input/Output)
Provides zone and output expansion for Galaxy
Systems
8 fully programmable zones
4 programmable outputs
Tamper protection
Rotary switch for setting module address
Audio interface module
Links 2 audio channels to provide audio
verification following an alarm activation
Audio interface PCB connects to panel and
PSTN Phone line
2 optional audio channels
Individual zones can be mapped to audio
channels
Optional 5-10 seconds of Pre and post-alarm
recording is stored
RS485 data line
10/16
7
Honeywell Galaxy
Dimension
Galaxy Dimension
Features:
Up to 64 doors controlled
Up to 1000 users
Protecting up to 32 groups
Door access controlled by access templates and
group set status
Groups can be set by pressing the
Menu Recall button before card swipe, or by triple
swipe
A system keypad can be linked to each reader for
Menu
Recall function control
Up to 32 audio verification channels
Multi-language interface
Compatible with all wiegand keypads that use
8-bit
Burst mode
New graphical colour TouchCentre
The new Galaxy Dimension series is the next
generation of intruder alarms from the established
Galaxy range. Based on the market leading Galaxy
3 series, it provides high quality, reliable security
solutions for commercial and industrial applications.
Galaxy’s latest version - Dimension - also now
includes enhanced access control features. With
one integrated system, operation is simpler for the
end user and is easier for the engineer to program,
commission and maintain.
Non PC Networked Access Control Solution Galaxy
Dimension combines the best intrusion features
with advanced access control functions in a single,
integrated system. Installing and programming a
full security system becomes easier, quicker and
more efficient. With only one system to install and
maintain, one point of contact for Technical Support
and one training session for the complete system,
there are savings in both time and money. Offering
this Non PC based access control system for small
industrial & commercial premises provides a user
friendly system with upgrade facility to integrated &
intruder & access control at a later date.
10/16
8
Honeywell Galaxy
Dimension
Panel Specifications
Description
Zones onboard (maximum)
Outputs (400mA) on-board
Trigger outputs on flying lead (10mA)
Integrated PSU
RS485 Databuses
Keypads (Keyprox)
Graphics Keypad Galaxy TouchCenter
Bus mounted prox readers (MAX)
DCMs with 2 x Wiegand interfaces
DCM controlled doors
Wireless RF Portal
Total Number of wireless sensors
Total Number of wireless key fobs
Users
7 Day Timer Schedules
Zone types
O/P types
Library
Event Log
Access Log
Multi-users
Autoset
Pre-Check
Timed Lockout
Links
Part Set
Silent Part Set
RS232
Integrated PSTN (V 22)
Printer Output
Remote Servicing
Ethernet module
Groups
Audio Verification channels
SMS text
ISDN
EN50131
10/16
GD-48
16 - (48)
8
6
2,5 A
1
8 (3)
1
4
4
8
4
32
50
100
19
52
81
Yes
1000
1000
Yes
Yes
Yes
Yes
64
Yes
Yes
Built-in
Built-in
Via RS232
Yes
Optional
8
8
Yes
Optional
Yes
GD-96
16 - (96)
8
6
2,5 A
2
16 (7)
2
16
16
32
8
80
100
250
35
52
81
Yes
1500
1000
Yes
Yes
Yes
Yes
128
Yes
Yes
Built-in
Built-in
Via RS232
Yes
Optional
16
32
Yes
Optional
Yes
GD-264
16 - (264)
8
6
2,5 A
2
16 (7)
2
16
16
32
8
192
100
1000
67
52
81
Yes
1500
1000
Yes
Yes
Yes
Yes
256
Yes
Yes
Built-in
Built-in
Via RS232
Yes
Optional
32
32
Yes
Optional
Yes
GD-520
16 - (520)
8
6
2,5 A
4
32 (24)
4
32
32
64
8
192
100
1000
67
52
81
Yes
1500
1000
Yes
Yes
Yes
Yes
256
Yes
Yes
Built-in
Built-in
Via RS232
Yes
Optional
32
32
Yes
Optional
Yes
9
Honeywell Galaxy
Dimension
Galaxy Dimension Systems Architecture
PSTN Line
RS232 (serial port)
6
Bus cables:
CAT5 cable or twisted pair screened
cable, Belden 8723 equivalent,1km maximum
A229
(Trigger cable to connect 6
additional outputs)
Line 4
RS485 BUS
Line 3
RS485 BUS
Line 1
16
GD-48
Line 2
8
GD-520
GD-96/264
Line 2,3 4
Line 1
A227
Same Cinfiguration for Buses
2,3 4
SPI Key (Copies Configuration) Remote Servicing
Suite
Galaxy Dimension
TouchCentre
Galaxy
Dimension
TouchCentre
Keypad or Keyprox
Keypad or
Keyprox
Black tag:YX0-0004
(Keyprox and Max)
Card:YX0-0002
(keyprox and
MAX
Max Badge Reader
MX04-NC
K-304329 4 random
multicoloured prox
tags
MaxBadge
reader
MX04-NC
CO80
CO80
DCM or DCM
with PSU
DCM or DCM
with PSU
CO81
CO81
Door
Lock
Weigand
Reader
Exit
Button PO25
Intelligent PSU 2.75A,
rated at 1.2A for grade 3
compliance Power RIO
combines Power supply
and RIO in one cabinet
C072
RIO Expander module, 8
inouts, 4 outputs C076
Wireless receiver
RF Portal
E080
Door
Lock
Intelligent PSU 2.75A, rated at
1.2 A for grade 3 compliance
8
4
Power RIO combines Power Supply
and RIO in one cabinet
PO25
8
4
Exit
Weigand
Button Reader
8
4
RIO Expander
modules, 8 inouts 4
outputs
Wireless receiver
RF Portal
Ethernet module
x1
A211
ISDN Module x1
10/16
10
Honeywell Galaxy
Dimension
Access Control Layout
RS485
bus
12 VDC Power in
Galaxy Dimension Board
Touch Centre
Mifare
34 bit OR
26bit
ioProx
Exit Button
Breakglass
Door Contact
Mag Lock
Use the DCM for fully programmable access
control and maximum choice of card/reader
technology
Order Codes:
C096-D-C1
C264-D-C1
CP046-00
Galaxy Dimension GD-96
control panel V6.78
Galaxy Dimension GD-520
control panel V6.78
Standard Touchcentre Prox
C080
C081
CP038-01-H
A229
A227
A228
A221
A234
10/16
Galaxy Door Control Module
Galaxy Power Door Control
Module
Standard keyprox with HID
format
Galaxy Dimension Trigger
Lead
Galaxy Dimension SPI
Programming Key (Blank)
Honeywell G2 Trigger Lead
Honeywell G2 Programming
Flash Lead
Honeywell Dimension RS232
cable kit
11
Honeywell Galaxy
Interfaces and Ancillaries
Interfaces and RF Ancillaries - G2 and Dimension
Panels
10/16
Description
Order Codes
C079-2
RF Portal V2 alpha protocol universal
C079-2
Slimline Door Contact
Slimline white door contact.
Slimline brown door contact
DO8M
DO800M2
Wireless PIR
PIR10m
RF PIR 10m Pet Tolerant version
IR8M
IRPI8M
Dualtec Motion Sensor
RF Dualtec Motion Sensor with Pet Tolerant
RF Dualtec Motion Sensor - High Security
DTPI8M
DT8M
Smoke Sensor
Honeywell Alpha & V2 protocal RF smoke sensor
DF8M
RF Round HUA
Honeywell Domonial RF Round HUA
TCPA2B
RF Set/Unset FOB
‹
”
‚#‘
"
"
#
ž”"
‚"
ž$ž”
TCC8M HON
round set/unset
RF Fob
TY-CR2032-BL5
Replacement
battery
(Pack of 5)
TCCBASE
Belt Clip Bracket
12
Honeywell Galaxy
Interfaces and Ancillaries
Interfaces and RF Ancillaries - G2 and Dimension
Panels Cont’d
10/16
Description
Order Codes
Shock Sensors with Contact
RF Viper (Piezo Shock Sensor) with Contact - White
RF Viper (Piezo Shock Sensor)with Contact - Brown
SHKC8M
SHKC8M2
Shock Sensor
Shock Sensor
Shock Sensor - Brown
SHK8M
SHK8M2
13
Honeywell Galaxy
Interfaces and Ancillaries
Interfaces and Ancillaries
Description
Galaxy Keypad
Galaxy Controllers will communicate with a number of keypads, ranging from
3 (Galaxy 8+/16), to 16 (Galaxy 18/60/128) and up to 32 keypads on the Galaxy
500/504/512. All the user and engineer controls are presented on the keypad
for simple operation. An uncomplicated, menu driven procedure leads any user
through the facilities available at that particular password level. Setting and
unsetting the system is carried out by entering a valid PIN and pressing the A key.
The keypad is supplied in two variants, either commercial or residential.
The residential keypad has “Hot Keys” which allow the user to generate a Police,
Fire or Assistance Call through to the Alarm Receiving Centre. Residential keypads
must be used on panels with residential defaults.
608.010.323 or CP051-36-01
Mk7 keyprox Mk8 keyprox
Galaxy Keyprox
The Galaxy Keyprox is a standard MK7/Mk8 keypad and a proximity card reader
combined into one housing. This allows dual function setting/unsetting ability from
the one unit without the need for a separate card reader. It is primarily intended for
use in situations where a PIN and/or card are needed to set and unset the Intruder
Alarm System. It is not intended to be used for door control as it does not contain
a door strike relay. However, limited door functions can be programmed using
programming links in the Galaxy Control Panels.
CP051-36-01
Galaxy Keyprox Mk8 Intruder keypad with Integral proximity reader Module
608.010.323
Galaxy Keyprox Mk7 Intruder keypad with Integral proximity reader Module
CP038-01-H
Standard keyprox with HID format
CP046-00
Standard Touchcentre Prox
1346LSSM-H10302.1
HID: 1346LSSM Format: H10302 ProxKey II Keyfob programmed for HIDs tracked
37bit Wiegand format. Supplied with HID logo on the front, back is standard finish.
Numbering is sequential internal & external. These can be ordered individually
Galaxy MAX04
MAX04 is a sophisticated door control module which uses proximity card reader
technology to combine performance with flexibility and economy. The MAX04 can
be integrated with the majority of the Galaxy range of control systems or operate
as a stand alone module.
MX04-NC Galaxy MAX04 Standard
Version with Normally closed relay
10/16
14
Honeywell Galaxy
Interfaces and Ancillaries
Interfaces and Ancillaries Cont’d
10/16
Description
Order Codes
Galaxy Keyprox + MAX04 Keyfob
Galaxy Keyprox + MAX04 Keyfob
A38403
Galaxy MAX04 Proxcard
Galaxy Keyprox + MAX04 Keyfob
A38402
Keyprox Keyfob
Pack of 4 random multicoloured prox tags
K-304329
15
Honeywell Galaxy
Interfaces & Ancillaries
Interfaces and Ancillaries
Order Codes
Galaxy G2 Replacement PCB
A246-63
Galaxy G2-44 PCB ADT RESIDENTIAL
Galaxy Dimension Replacement PCB’s
A322-C-C1
Galaxy Dimension 96 UK PCB
A323-C-C1
Galaxy Dimension 264 UK PCB
Order Codes
Plug-On Expander for Galaxy Dimensions
The Plug-On Expander for Galaxy Dimension expands from 264
to 520 zones.
E485-2
Galaxy Telecoms Module E062
7633
Galaxy G2 External Signalling Interface
Galaxy G2 External Signalling Interface for Redcare or DualCom
Plus
A232
E080-04
Ethernet Module
Ethernet Module PCB only. Compatible with Galaxy classic V400
and later, and G3 Panels.
10/16
Galaxy RIO
Galaxy Remote Input Output Unit (RIO) in Plastic Box. 8 Zone
Input, 4 Darlington Driver Output, Data Bus Interface (C072-36).
608.010.055
Honeywell Galaxy Door Guard
Door Guard Interface A module which is used to provide
$‘
The Door Guard Interface can be configured for both stand-alone
use (connected to a power supply only) or as an integrated
unit with the Galaxy security system providing details of door
$?‘”#
$#$`
access to a protected area results in a local, audible warning as
well as an indication at the Galaxy panel
6631
Galaxy Door
Guard (CO75)
C075W-C
Honeywell Door
Guard (common
key)
16
Honeywell Galaxy
Interfaces & Ancillaries
Printers & Interfaces
Description
Printer Interfaces
The LQ 300 printer is designed as a low cost business printer ideally suited for use
with the Galaxy range of Control Panels (use 6521). The printer interface allows
either real time printing of all events or print, on request, of items held in the log.
The printer interface will operate in conjunction with any standard serial printer.
6521
Galaxy printer interface. Converts RS485 data base to RS232 standard printer
output format. 25pin D-Connector.
557.180.239
LQ 300+II Epson Dot matrix alarm printer - 24 pin 80 character
Ancillaries
Description
The Galaxy 4 way relay interface is used with RIO’s to connect the 12V Darlington
Driver outputs to clean relay signals. This is particularly useful to trigger response
events on a CCTV System or other monitoring type package. The Galaxy Doorguard
unit provides an d”Exitguard” facility when used with Galaxy 60/500 or 512.
“Exitguard” enables a fire exit door to be monitored locally, even when the alarm is
unset. Anyone opening the fire exit door will cause the buzzer to sound. Operation
of the on bard keyswitch isolates the door and allows authorised access/egress
without an alarm being raised.
6628
Galaxy 4 way relay interface to convert Darlington driver outputs of field device
interface to clean relay outputs.
A221
Galaxy G2 programming lead for use in upgrading software versions with a laptop,
file needed from resolve
A234
Galaxy G3 & Domonial RS232 cable Kit, for use with G3 and Dimension Panels
10/16
17
Honeywell Galaxy
Interfaces & Ancillaries
Technical Specifications
Mechanical (all variants)
Enclosure (with PCB and transformer) Width:
440 mm, Height: 352 mm,
Depth:
90 mm, Weight:
6.4 kg
Physical space for batteries
2 x 17 Ah Max (not
suitable for 12 Ah
batteries)
PCB only Width:
265 mm, Height: 120 mm,
Depth:
47 mm, Weight:
0.3 kg
Operating temperature: -10 deg.C to + 55deg.C
Fuses
AUX1
AUX2
BELL
BATT GD-48
BATT GD-96/264/520
PSTN
RS232
RS485
1.0 A - 20 mm anti-surge
1.0 A - 20 mm anti-surge
1.0 A - 20 mm anti-surge
1.0 A - 20 mm anti-surge
1.6 A - 20 mm anti-surge
V.22 Modem 1200 Baud
300 - 56k programmable
9600 Baud, Full Duplex,
Asynchronous
Electrical
Mains input:
230V ac (+10%/15%) @ 50 Hz
Power supply:
Type A
GD-48
Total capacity 1.5
A (0.75 A
dedcated to battery)
Operating temperature: -10 deg.C to + 40 deg.C
Power supply:
Type A
GD-96/264/520
Total capacity 3 A (1.5 A
dedicated to battery)
Operating temperature: -10 deg.C to +40 deg.C
Auxiliary + 12V outputs: 12 V nominal
GD-48
0.5 A in total
50.0 mV maximum
ripple
Auxiliary +
12 V outputs: 12 V nominal
GD-96/264/520
1.0 A in total
50.0 mV maximum ripple
10/16
18
Honeywell Galaxy
Interfaces & Ancillaries
Module Specifications
Modules
Galaxy Keypad (MarkVII)
Size:
Galaxy Keyprox (Mark VIII)
Size
Keypads Material
Keypad Colour
Galaxy TouchCenter
Size
MAX3 (Boxed)
Size
Galaxy RIO (Boxed)
Size:
Galaxy RF RIO (Boxed)
Size
RS232 Module (Boxed)
Size:
Door Control module (Boxed) No PSU
Size
Door Control module (Boxed) with PSU
Size
Line Expander
Size:
Doorguard
Size:
Printer Interface (6-Way DIN Plug)
Printer Interface (25-Way D Plug)
Box Size:
Cable Size:
10/16
Weight
190 g
149 x 91 x 31 mm (L x B x H)
190 g
149 x 91 x 31mm (L x B x H)
500 g
182 x 128 x 34 mm (L x B x H)
267 g
185 x 120 x 48 mm (L x B x H)
300 g
150 x 162 x 39 mm (L x B x H)
270 g
150 x 162 x 39 mm (L x B x H)
823 g
180 x 155 x 35 mm (L x B x H)
270 g
150 x 162 x 39 mm (L x B x H)
300 g
150 x 162 x 39 mm (L x B x H)
820 g
180 x 155 x 35 mm (L x B x H)
995 g C075
150 x 185 x 40 mm (L x B x H)
120 g
130 g
75 x 52 x 28 mm (L x B x H)
2 m for 4-Way IDC, and 0.3m for 6-Way/25Way plug.
Order Code
CP027
CP028
PC + ABS
Neutral
CP040
MX03
C072
C076
E054
C080
C081
A226
6631
A134
A161
19
Honeywell Galaxy
Galaxy PC Package
Galaxy User Management Suite
Features:
Programmable user functions
System and door access event log copying
Displaying and printing of selected event log
categories
Off-line data programming
Password protected access to Galaxy panels
Password protected access to User Management
Suite
Single local site servicing
Multiple remote site servicing
The Galaxy User Management Suite software has
been developed specifically for in-house Security
Managers.
This software provides a user-friendly interface to
key functions of the Galaxy security system allowing
essential changes and amendments resulting
from personnel changes or opening hours to be
made, ensuring smooth and continuous day-to-day
operation.
The software provides access to:
`
^$#
[
ƒ”#$"Œ©
#$
‚
User Management Suite can connect to Galaxy
security systems via the following communications
media:
Technical Specifications
Operating system
Processor
Memory
Hard Disk space
Comm Ports
Windows 98SE, 2000, ME,
XP, NT4 with SP3
P3 600 Mhz minimum
128 MB minimum
500 MB minimum. More
may be required depending
on size of database
1 or 2
Order Codes:
R058-CD-DG
YY0-0010
End User system
management software UMS
Extra operator Dongle for
UMS
For remote Galaxy sites allowing communication
with multiple control panels:
‚[‡$}<'#[
Module)
—‚?‡}<'#—‚?‡_~©
|]ž[^}[ —~
”}<'#^_~©
For local Galaxy sites:
<'#
panel via the Galaxy RS232 Module
The Galaxy User Management Suite menu options
provide the operator with a comprehensive range of
features that allow site data be copied to and stored
on the controlling PC or modified overwritten to
control panels.
©‚"$"<'#$
used. The Galaxy 2 series system can’t be used with event monitoring
software.
10/16
20
Life Safety Devices
This chapter contains information about our range of Life Safety Devices
Introduction
Carbon Monixide (Smoke)
Smoke and Heat Detectors
Service Tools
09/15
1
Life Safety Devices
Introduction
Reducing injury, death and the costs of damage
Our range of home Safety devices provide the
first line of defence for keeping a home and family
safe from dangers such as fire, smoke & carbon
monoxide poisoning and reducing the cost of
fire damage. (See Visonic section for RF devices;
including natural gas and flood detection)
Because each detector is connected to the control
panel, you will be alerted by sound and by visual
display on the control panel. In addition, in the
event of an incident alarm, the security monitoring
services will immediately contact the keyholders
and in most cases the local fire services - so, even if
you are not home or you are sleeping, you can take
immediate steps to protect children, elderly parents
or others who may not be aware of the immediate
danger.
Additional products such as a fire blanket and
extinguisher are also available that can be used in
places such as the home or a caravan.
Separate testing devices are available at the end of
this chapter.
09/15
2
Life Safety Devices
Carbon Monoxide (Smoke)
SGU-601
Features:
Detects most carbon based types of fires
Provides very early warning for slow smouldering
fires
Ideal for sleeping risks such as residential homes
High resistance to false alarms
Tolerant to various detector mounting positions
Negligible sensitivity to air speed
Compatible with most existing residential burglar
alarm systems
Low profile, discreet and unobtrusive
Environmentally friendly
CE marked
The SGU-601 is based on the MU601 Carbon
Monoxide Fire Detector which is used for
commercial fire detection systems. The SGU-601
is powered from external 12 Vd.c. and provides a
non-latching alarm signal to the panel when Carbon
Monoxide levels exceed the fire detection level.
The following design rules should be followed when
applying the SGU-601:
[‚<`Œˆ]|
Residential Intruder detection systems only
Š#‚<`Œˆ]|
detection zone
$"
"
station signalling
$
indicate fire condition
$
internal sounder should be used
Order Codes:
616.023.001
617.050.001
616.023.001.A
616.023.007
SGU-601 12 V CO Fire
Detector for use with
Residential Intruder Alarm
Systems
SG600 Detector Base
for SG601 12 V CO Fire
Detector
SGU-601 12 V CO Fire
Detector for use with
Residential Intruder Alarm
Systems with ADT Branding
SGU601 12 V CO Fire
Detector complete with
SG600 Detector Base.
For use with Residential
Intruder Alarm Systems.
ADT Branded
Technical Specifications:
CO Detection
Threshold:
40ppm
Detector Material: FR110 “Bayblend” Fire Resistant
Dimensions:
Ø106 x 53 mm
š
]”
$$'
š
Operating
Temperature:
Range 0° to +50°C
Storage Temperature:
-25°C to + 80°C
Relative Humidity: 95% non-condensing
09/15
3
Life Safety Devices
Smoke Detection
System Sensor 12 V Smoke Detector
Features:
Dust tolerant chamber provides optimum
detection performance and minimal nuisance
alarm between maintenance visits
Alarm test
Photoelectric, multi-criteria photo-thermal, fixed
and rate of rise thermal detectors
Backward compatibility with Series 100 bases
enables upgrade, extension and maintenance of
existing installations
8 to 30 VDC operating range enables operation in
both fire and security systems
-30 to +70oC operating temperature range
Multi-functional Alarm - Normal bi-colour LED
indicator
EN54 (2000) part 7 Certified (Amendment 1)
The series 300 range of detectors has been
produced using the latest in manufacturing and
design techniques, pushing out the boundaries of
'#
multitude of innovative features, the Series 300
is a detector which “acts conventionally, thinks
intelligently”.
Series 300 is the paradigm shift in conventional fire
detector technology. This new range is the first to
benefit from our latest innovation-remote test and
configuration capability from the ground using a
handheld test. Series 300 is feature rich, including
sensitivity selection, addressability, and status
indication using a bi-colour LED.
Technical Specifications:
Dimensions:
Supply Voltage:
Power:
Order Codes:
2351-E
2351TEM
Service and maintenance is also simplified because
the contamination level of the serving chamber can
be read maintenance dates can be written and an
alarm test can be instigated - all through use of the
same handheld tool.
4351-E
Systems Sensor’s range of conventional relay bases
can be used to interface smoke detectors to 4 wire
security panels or to provide relay output suitable for
$"
2 wire fire alarm panels. The bases are compatible
both with 4 wire security type systems using a
normally closed contact and 4 wire fire alarm panels
using a normally open contact.
B312RL
09/15
102Dia mm (Detector)
29H x 127 dia mm (Base)
15-32 Vdc (Detector)
9.5 V-15.0 Vdc(Base)
6.5 [email protected] Vdc (Detector)
25 [email protected] Vdc (Base)
5351E
B312NL
SYS Low Pro Optical Smoke
Detector
SYS Low Profile MultiCriteria Smoke/Heat
Detector
SYS Fixed Temp (78°C) Heat
Detector
SYS Rate of Rise Temp
Detector (58°C)
SYS 12 Volt Non-Latching
Relay Base
SYS 12 Volt Latching Base
4
Life Safety Devices
Service Tools
Point Detector Testing/Commissioning Equipment
Description
Telescope Poles
SOLO100 Telescopic pole 1.26M to 4.5M long
SOLO101 Extension tube 1.13M long for use with 517.001.230
Telescopic extension pole
SOLO 610 Protective Carry/Storage Bag for Solo Detector Test
Kit
Order Codes
517.001.230
517.001.226
517.001.264
517.001.255
SOLO330 Smoke and CO Dispenser
SOLO330 Aerosol dispenser for use with all detector ranges.
Connects directly to SOLO100/101 poles
SOLO461 Heat Detector Tester
SOLO461 Cordless heat detector tester kit including SOLO460
tester
SOLO720 battery batons and SOLO724 charger. (Connects
directly to SOLO100/101 poles).
SOLO720 Spare battery baton for use with SOLO 450/460
tester
SOLO725 Spare mains/car battery charger for SOLO720 battery
baton
Smoke Detector Test Gas
Suretest Solo aerosol tester can. For use with SOLO 330
dispenser. Nonflammable, ozone and environment friendly.
Approx 200 tests per can
517.001.254
517.001.242
517.001.243
517.001.256
CO Detector Tester
CO Detector Tester Solo C3-006 for use with Solo 330 dispenser 517.001.262
09/15
5
Power Supply Units
This chapter contains information about our range of Power Supply Units
Introduction
Standalone PSU’s
Galaxy PSU
09/15
1
Power Supply Units
Introduction
Day alarms
Our extensive product range that is manufactured
exclusively in the UK, includes trusted brands, such
as Exitguard, Multiguards, and Aidalarms. There
are a number of different models to suit various
applications.
All Hoyles products comply with ISO9001 quality
standards.
Multiguard
The MULTIGUARD is a general purpose six zone
annunciator. The enclosure design is such that
virtually any system size can be met by stacking
units together. To cater for the many different
requirements of the emergency alarm market the
Multiguard is supplied in a number of different
guises, each of which offers a remarkable degree of
flexibility.
Possible uses for the Multiguard are Perimeter
Protection Systems, Personal Attack Monitoring, Fire
Exit Door Monitoring (e.g. EXITGUARDs) and Nurse
Call Systems.
Aidalarm
The AIDALARM meets the growing demand for
an emergency signalling system for handicapped
persons. It is particularly suitable for disabled
toilets in public buildings such as colleges, libraries,
municipal buildings and shopping centres etc..
AIDALARMS can be powered from either 12vdc or
240vac. A range of accessories are available: Ceiling
mounted pull cords with re-assurance LED, wall
mounted call and reset buttons and remote audible
visual indicators.
It is fully compliant with BS8300 and the Disability
Discrimination Act.
Zoneguard
ZONEGUARD ZG800 is a Grade 3 EN50131 zone
omit unit that fits between intruder detection
devices and a control panel to allow the devices
to be securely and safely omitted and reinstated
without generating false alarms
Exitguard
Exitguard is the ideal solution for security of fire exit
doors. An integral high power sounder is activated
when the door is opened to warn those in the
vicinity that security has been breached.
09/15
2
Power Supply Units
Standalone Units
Elmdene Power Supply
Features:
EN50131-6 Type A compliant
EN50131 Environmental Class II
Fault Status monitoring
High Efficiency Circuit Design
Comprehensive output voltage and current
protection
Deep Discharge Protection
Lid and Rear Tampers
Elmdene Range
The EN range of standalone power supplies from
Elmdene have been specifically designed to provide
a comprehensive and flexible range of options for
Intruder Systems complying with PD6662: 2004/
prEN50131-1.
The Power Supplies comply with the requirements
of EN50131-6.
Note: Standby periods for power supplies are:
Order Codes:
GEN2-08-B
GEN2-18-B
GEN3-08-B
GEN3-18-B
EN3-34-R
G13801N-A
EN50131 Grade 2 8 Ah PSU
EN50131 Grade 2 18 Ah
PSU
EN50131 Grade 3 8 Ah PSU
EN50131 Grade 3 18 Ah
PSU
Elmdene Grade 2/3 3.0
A PSU without a Rio.
Standalone version that
does not sit on the bus. 2
outputs for battery and
mains faults.
Elm Switchmode 12 V
1 AMP Non EN PSU
Technical Specifications:
Product
GEN2-08-B
GEN2-18-B
GEN3-08-B
GEN3-18-B
EN3-34-R
G13801N-A
09/15
Case Size
B
B
B
B
B
A
Max Output
1 Amp
1.4 Amp
1 Amp
1.4 Amp
3.00 Amp
1 Amp
Battery Size
8 Amp
18 Amp
8 Amp
18 Amp
17 Amp
7 Amp
EN 50131 Grade
2
2
3
3
3
N/A
Size H/W/D mm
330 x 355 x 80
330 x 355 x 80
330 x 355 x 80
330 x 355 x 80
330 x 355 x 80
200 x 230 x 80
3
Power Supply Units
Galaxy PSU
Power Rio
Features:
Fault outputs
On Board Rio
EN50131 Grade 3
Sits on databus
Complies with EN50131-1:2009
Security Grade - 3
This Power RIO (P026-01-B) can be used for the
Order Code:
G2-20 & G2-44 panels as well as the G3 range. It is
P026-01-B
also backwards compatible with the existing Galaxy
Classic range. The Galaxy series 3 Power Supply
Unit consists of 2 modules, the Power Block and the
Control Unit. The PSU can be connected to the G3
control panel via the RS485 (AB) line.
ICP Galaxy Grade 3
compliant smart 2.75A PSU
with RIO
Technical Specifications:
The PSU can be used in place of a standard RIO to
overcome power problems that arise when the
additional RIO is fitted distant to the control panel. A
6-way jumper lead connects the Power Block to the
Control Unit. The PSU has 8 zones and 4 outputs.
Addressing is identical to that described for RIO
Modules.
FAULT OP AC: This is an open collector transistor
which is normally off. The output is activated by an
AC failure.
FAULT OP BAT: This is an open collector transistor
which is normally off. The output is activated by a
Battery Low or Battery Fail condition.
FAULT OP POWER: This is an open collector
transistor which is normally off. The output is
activated by low voltage present in +12 V1, +12 V2
or +14.5V.
Battery
The minimum capacity battery to supply the PSU is
1x 7 Ah. The maximum capacity battery to supply
the PSU is 2 x 17 Ah.
Electrical
(Based on 34 AH battery and UK grade 3 compliance)
Input voltage:
Output voltage:
(nominal)
Output Current:
(max)
Operating Temp:
Aux 1 & Aux 2
Output voltage:
(nominal):
Output current:
230 Vac(+10%/-15%)@50 Hz
13.8 V & 14.5 V
3.0 A
-10°C to +40°C
13.8 V
14. V
0.15 (when using this current, the
AUX1 & AUX2 currents will be
reduced by an equivalent
amount).
Current (max):
1.4 A
Maximum ripple voltage less than 100 mV
Fuses
F1 (14.5 V)
500 mA - 20 mm anti-surge
F2 (Battery)
1.6 A - 20 mm anti-surge
F3 (Aux1)
1.0 A - 20 mm anti-surge
F4 (Aux2)
1.0 A - 20 mm anti surge
Note: ADT’s preferred option is to use 1 x 17 Ah battery.
Standby periods for power supplies are:
<|<ª|
<<!ª!
Standby period for Grades 3 & 4 is halved if PSU Fault is
signalled to the ARC.
09/15
4
Radio Equipment
This chapter contains information about our range of Radio Equipment
Introduction
EMS
Scantronic
09/15
1
Radio Equipment
Introduction
The Scantronic Radio products can be used in many
different applications such as;
‰
? ž
A simple transmit/receive configuration can be used ^#ž
«˜”•‚#
to interconnect conventional devices in out-buildings It should be noted that the effectiveness of a radio
to the main alarm systems
system is dependent on the building construction
and background noise. It is recommended that a
The EMS range of radio based products intended
radio test is carried out before installing this type of
for use as personal attack systems in all types of
financial, industrial or commercial premises where
system.
staff need the security of a personal attack alarm
with the freedom of mobility.
The use of radio transmission within an Intruder
Alarm System can be beneficial where cabling of
devices is not practical.
In addition, portable personal attack buttons enable
personnel to summon assistance from any location
within a building.
Scantronic Radio Systems are an integrated range
of FM transmitters and dual conversion superheat
receivers that feature the latest SMD technology and
long life LTC batteries.
09/15
2
Radio Equipment
EMS Equipment
UHF System 7000 Intelligent Radio Information
System (IRIS)
Features:
Completely wire free
Individually identifiable
`‘#
The transmitters are also suitable for fixed positions,
and, as the system is devoid of interconnecting
wiring, any alteration can be carried out quickly and
inexpensively. False alarms caused by damage to
traditional 24 hour live personal attack wiring circuits
are totally eliminated. Up to 256 transmitters,
each individually identified by the receiver make
up the standard IRIS UHF personal attack system.
Each transmitter is uniquely coded and cannot be
duplicated.
The transmitters are also suitable for fixed positions,
and, as the system is devoid of interconnecting
wiring, any alteration can be carried out quickly and
inexpensively. False alarms caused by damage to
traditional 24 hour live personal attack wiring circuits
are totally eliminated.
Up to 256 transmitters, each individually identified
by the receiver make up the standard IRIS UHF
personal attack system. Each transmitter is uniquely
coded and cannot be duplicated.
Every event is time and date stamped, held in an
incident log and viewable from the LCD display.
After resetting, the events are then transferred to
the historical log, also viewable from the display, or
via an optional plug-in printer. The IRIS radio system
supports numerous other integrated devices for
gathering information from fixed or portable alarm
inputs. This information can then be displayed locally
on the receiver or used to send onward signals via
an alarm transmitter.
Description
Order Codes
7206
^ž”"€†]$€†€|
7207
^ž”"€†]]
^ž”"€]]
09/15
7507
3
Radio Equipment
EMS Equipment
Description
Order Codes
ˆ]†]|||€†
^_‚€†|| ž —‰^?‚ž
ˆ]†]|||
^_‚€†€]?$
EMS IRIS UHF
Description
Order Codes
€ˆŒ˜`‚
EMS IRIS UHF Multi Funcion RF REC
€
EMS IRIS UHF HIgh Gain Aerial
7500-2
^_‚—‰—‚`‹[¦ž
7500-3
EMS IRIS UHF hand TX
7723
EMS IRIS UHF Transponder
€†]Œž
^_‚—‰—‚`‹[¦ž
€†]Œ‚
^_‚—‰—‚`‹[¦ž‚¥‚
€†]Œ
^_‚—‰—‚`‹[¦
€†€|Œžž
^_‚‚ž#ž”ƒ
7K67J
ˆ
#"€†]]”
09/15
4
Radio Equipment
EMS Equipment
UHF System Single Zone Receivers
Features:
Dual action buttons for “full alarm” transmission
Secondary single action button for local or
ancillary alarm
Š$
#
"
buttons
Operation for full alarm generation
[€€]$”#"
use in all types of financial, industrial or commercial
premises where staff need the security of a
personal attack alarm and also the freedom of
mobility. They are also suitable for fixed positions
and, as the system is devoid of interconnecting
wiring, any alteration can be carried out quickly and
inexpensively. False alarms caused by damage to
traditional 24 hour live personal attack wiring circuits
are totally eliminated.
"$$!
€€]`‹$”
system has a typical range up to 250 metres.
All transmitters including the fixed money clip are
powered by an Alkaline battery giving a minimum of
one year battery life.
Technical Specifications:
?š
]'|]'ˆ?
Š$‹‘š
!!_}_[
|†~$
œ
‚$$#ƒš
|ƒ!ƒ
š
ˆ]|ƒ
Inputs Radio Transmitters:
۠]]
['
۠|]_#$['
Š$š
#$|
!ƒ
!ƒ„|
_'}ƒ~
Order Code:
ˆ]†]|||]
09/15
^_‚€€]`‹
receiver
5
Radio Equipment
Scantronic Equipment
Scantronic
Features:
Full range of transmitters and receivers for all
applications
#$"«•
unit
2 channel receiver compatible with all alarm
control panels
}'$
ˆ!~
|ƒ$
Fully programmable, multi option transmitter
Scantronic Radio Systems are an integrated range
of FM transmitters and dual conversion superheat
receivers that feature the latest SMD technology
and long life LTC batteries. The entire range is fully
approved by the DTI for use on the professional
#"‘#ˆ_
The Scantronic Radio products can be used in many
different applications such as;
Alarm Retransmission
`€]Œ]]€!Œ]]
collect the alarm output from detectors or remote
control units, and transmit them back to the control
unit of the main building system.
This can be very useful in areas where there are
outbuildings or remote garages.
Each individual can have full local control, via its own
control panel, but any alarm signals can be brought
into the main security system.
09/15
Emergency Panic Button
Use a 726recur-60 hand held panic button with
€ˆŒ]] €ˆŒ]
conventional burglar alarm control panel to provide a
fully mobile panic button facility. Ideal for use in
homes, garage forecourts, where cash is moved
around or where you have guards left alone in
industrial premises.
‘Lone Worker’ Protection System
`€]|Œ]$€ˆŒ]
$
€ˆŒ]] €ˆŒ]
receiver connected directly to a conventional
intruder alarm panel, to provide a means of
$"«”•
or injured whilst working alone.
A special version hand held panic button
(706recur-00), has an extra safety feature built in; a
mercury tilt switch is included and will automatically
activate the transmitter should the worker fall
further than a nominal 45 degrees, from the vertical,
for longer than eight seconds. This is of
particular importance to those people working
in areas where there is a risk of falling or being
overcome by toxic fumes.
6
Radio Equipment
Scantronic Equipment
Scantronic
Description
Order Codes
Programmable, multi-function 4 channel transmitter (including
792recur-00antenna)
Œ"!}
€†Œ]]~ž‡”"'$€†
| !|ƒ? '
”
batteries.
#
˜^?
€]‰^`‰Œ]]
706REUR-00
Lone worker unit with addition PA function
˜”"_Œ
"
alarms.
ž$˜‚Œ$
˜
battery.
Double action personal attack transmitters
?
”$
operation (includes belt clip). Sealed-unit, non-replaceable
lithium battery.
726REUR-50
726REUR-60
€|]‰^`‰Œ]]
€]|‰^`‰Œ]
€!‰^`‰Œ]]
4 Channel Door Contact
4 Channel Door contact with integral magnetic contact (magnet
$$~$~~ƒ$$
"”|'‰$
#
(supplied).
762REUR-00
2 Channel Programmable receiver
[«˜•"Œ}|ˆ]]]]]]
permutations). Auto recognition of transmitter type and auto
configuration. Two alarm output relays. Five status output relays:
low battery, jamming, supervision, Aux fail, temper. Integral
filed strength meter. Eight LED indicators. Features AE2 dual
##"'
†Œ|ƒ?'
09/15
7
Radio Equipment
Scantronic Equipment
Scantronic
Description
Order Codes
[«˜•"Œ}|ˆ]]]]]]
€ˆ‰^`‰Œ]
permutations). Auto-recognition of transmitter type and auto
configuration. Two alarm output relays. Five status output relays:
low battery, jamming, supervision, Aux fail, tamper, Integral field
strength meter.
Eight LED indicators. Features AE2 dual diversity receiver
#"'ž‡
socket.
Anti-tampered polycarbonate housing.
Antennae for 700R
"€]]‰ž‡”
—| !€]‰€†]‰
]ˆ]]^`‰Œ]]
€†‰^`‰Œ]]
— '| •'
€†!‰^`‰Œ]]
fixing bracket
— | '
"' €†€‰^`‰Œ]]
bracket
09/15
8
Signalling
This chapter contains information about our range of signalling
Introduction
RedCARE Secure IP
RedCARE Secure
RedCARE Secure Solo
RedCARE 5G
RedCARE GSM
Dualcom
Webway IP
Digital Commicators
Voice Dialler
Acessories
09/15
1
Signalling
Introduction
Intruder Alarm Systems provide the optimum
protection when used in conjunction with an Alarm
Receiving Centre. In the event of an alarm condition
the Intruder System will send a signal to the Alarm
Receiving Centre who will then take appropriate
action, e.g.. summon police, fire brigade etc.
There are several ways of transmitting the signal
from the site to the Alarm Receiving Centre. The
method of signalling will depend on the level of risk
associated with the premises.
Selecting Appropriate Signalling Device
Types of Signalling
Standard Intruder Alarm Control Panels have fitted
as standard a digital communications device which
signals over a standard PSTN (Public Switched
Telephone Network) Line. If the line is cut then
the Central Station is not notified, there is only
local indication of a line cut. This type of signalling
is adequate for Level 1, Low Risk Residential
Customers.
RedCARE Secure
Redcare Secure signals with an ARC in two ways.
The mobile telephone network
DualCom GPRS
DualCom GPRS, from CSL DualCom Limited, is an
intruder alarm signalling device that uses both the
Vodafone network and your telephone path to
transmit intruder and personal attack signals at high
speed.
Once the alarm is confirmed as genuine, police are
notified. Utilising two signalling paths ensures that
DualCom dual-signalling will always have a back-up
path in the event of an accidental or deliberate fault
on either path.
IP Signalling
IP uses the internet to carry security
communications instead of the old switched
telephone network. This means that vastly more
information, of vastly different kinds can be sent
without the need for dedicated lines;
information such as voice, data and high definition
CCTV. It also allows that information to be two-wa,
so a monitoring centre can communicate with a
remote site, interrogate it’s health, control cameras
and even conduct remote maintenance. There’s also
considerable pressure from the telecommunications
companies themselves or the security industry to
switch to IP. Because IP uses less bandwidth than
conventional methods, it frees up capacity to
be used for other purposes such as on-demand
television.
The wireless path is provided by GPRS which is a
digital mobile phone network. The wireless works as
the primary path on Secure 2 and 3 and as a back up Indeed much of the European telecom network is in
the process of planning the withdrawal of
on a Secure IP.
the services that makes non-IP security
communications possible.
The wireless path will deliver the signalling to and
from your alarm.
Digital Communicators
Digital Communicators offer a cost effective means
RedCARE
of transmitting signals to an Alarm Receiving Centre.
RedCARE is a polled device signalling over the
They connect to a standard telephone line (PSTN)
PSTN.
and in the event of an alarm “phone up” the Alarm
If the line is cut then both the Customer and the
Receiving Centre and exchange code information. If
Central Station are informed.
the telephone line is cut the Alarm Receiving Centre
is NOT notified and the system reverts to local
RedCARE GSM
RedCARE GSM works in the same way as DualCom indication only. As all signalling devices are wired-in
they require to placed in a housing. You will require
GSM just on a different GSM network. If using
an Elmdene 12 Vdc
RedCARE GSM you must test the signal strength
1 Amp PSU.
where the control panel will be located.
EN2-7B
EN2-17B
EN3-7B
EN3-17B
In addition, they use battery PS-1270, PS-12170.
09/15
2
Signalling
Redcare
RedCare Secure IP
Features:
No additional set up or installation costs
No extra call costs
The secondary path uses mobile technology or a
phone line
Intelligent roaming SIM
Easy installation
Remote upload / download
Flexibility
Regulatory compliance
Round-the-clock support
Redcare Secure protects customers with a choice of
a grade 2, 3 or 4 dual path alarm signalling or grade
2 wireless only alarm signalling, using BT’s trusted
Redcare network.
Order Code:
SECURE-IP
Redcare Secure IP/GPRS V3
The dual path system ensures that, if one path
fails, there is another signalling path allowing any
critical alarm messages to reach the ARC. The alarm
signalling paths are provided by wireless mobile
phone technology and a phone line or broadband (IP
connection) to deliver the alarm signal.
Technical Specifications:
Secure Upload / Download
Uses GPRS or IP, avoiding need for PSTN
Currently supports most panels including Honeywell, Coope Scantronic, Risco, Texecom, Castle
Available via Dial Capture and RS232/485
Full compatibility list available on request
Secure Roaming
Always connects and locks on to a strong signal
Automatically connects to the next best network in
the event of failure Does not rely on a signal from a
single network operator Signalling details
Wireless connection via 24/7 VPN over GPRS
Phone line signalling via VPN dial-up session on any
PSTN connection
Continuously polled IP path when used in IP mode
Dual band (900/1800 MHz)
Alarm messages and polling are highly encrypted to
EN grade 4 using Triple-DES encryption
Software and firmware anti-substitution measures
to EN grade 4 Unit and service faults are
self-reported Full integration with the BT Redcare
ARC Gateway.
09/15
Power specifications
Nominal 13.5 V input (9.5 V to 30 V)
Screw terminals
Low battery alarm reporting to ARC MkII: Average
230 mA, peak 280 mA (peak 450 mA if using Dial
Capture)
MkIII: Average 110 mA, peak 130 mA (Average 174
mA,
peak 395 mA if using Dial Capture)
Alarm panel interfaces
16 alarm input pins
3 outputs
Optional Dial Capture with phone line simulation
Relay to allow panel PSTN upload/download in Dial
Capture mode Onboard RS232 and RS485 for direct
panel interface to some panels
3
Signalling
Redcare
RedCare Secure
Features:
Network compliant, meaning your product
will continue to work as BT upgrades the UK
telephone network. Secure’s
GPRS wireless network provides 99.7%
availability.
PD6662: 2004 scheme for EN standards in I&HAS
EN50131-1: Alarm systems. Intrusion systems
EN security standards. Environmental Class II
Compliant for interface to fire alarm panels
REN value 0.1
Redcare Secure is an alarm signalling system that
comes in Two platforms.
Technical Specifications:
Depending on the risk level of your home or
business premises and your technology preference
you can choose between Secure 2 (for Grade 2 risk),
Secure 3 (Grade 3 risk).
Power specifications
Nominal 13.5 V input (9.5 V to 30 V)
Screw terminals
Low battery alarm reporting to ARC
Average 230 mA, peak 280 mA (peak 450 mA if
using Dial Capture)
Redcare Secure benefits from being a ‘dual path’
system, which means that two separate routes are
used to signal the alarms to your Alarm Receiving
Centre (ARC). So, in the event of one path being
faulty or unavailable the alarm message will get out
over the other path. With our Secure 2 and Secure
3 service a wireless network link provides the
‘primary path’, with the back up ‘secondary path’
being provided by your fixed telephone line.
The UK fixed telephony network (PSTN), IP
connection or broadband line
The fixed link uses your telephone line, IP
connection or broadband line. Alarms signals
are quickly sent over the fixed line and we make
continuous checks on the fixed link, reporting
line failure in a few minutes to your ARC allow for
prompt action to restore service.
General purpose inputs and outputs
Sixteen general purpose alarm inputs (Logic High =
+3.5 V to +30 V/Logic Low = -0.5 V to +0.8 V)
Unconnected state: Logic Low
Screw terminals
Line fault output – for status indication at site of
alarm signalling paths
Return path signalling – for confirmation at site of
opening and closing
Control output – for remote control of site devices
BSIA F175 enabled
Size and weight of unit
168 x 115 x 36 mm, 500 g
Order Codes:
SECURE-V3
608.009.188
WHITESTICK
EXT-CABLE
09/15
Redcare Secure GPRS/
PSTN V3
GSM STU 5 metre
extension antenna for use
with 608.009.187
WHITESTICK extension
aerial
10 metre extension cable
4
Signalling
Redcare
Redcare Secure Solo
Features:
No associated call costs.
Provides standards compliant with Grade 2
signalling
Redcare solo is supplied with Redcare’s roaming
SIM as standard.
No need for a fixed telephone line.
Redcare solo is ideal for construction sites,
vacant properties, remote buildings, cabins and
outbuildings.
Resolve upload/download
The RedCare Secure Solo is a grade 2 signalling
device which is specifically designed for use in
homes or commercial premises where no land line
is available. The unit can be used anywhere that has
a good GPRS signal.
Redcare Secure and Secure Solo protect customers
with a choice of a grade 2, 3 or 4 dual path alarm
signalling (Secure) or grade 2 wireless only alarm
signalling (Secure Solo), using BT’s trusted Redcare
network.
The dual path system ensures that, if
one path fails, there is another signalling path
allowing any critical alarm messages to reach the
ARC. The alarm signalling paths are provided by
wireless mobile phone technology and a phone line
or broadband (IP connection) to deliver the
alarm signal.
Technical Specifications:
Power specifications
Nominal 13.5 V input (9.5 V to 30 V)
Screw terminals
Low battery alarm reporting to ARC
Average 110 mA, peak 130 mA (Average 174 mA,
peak 395 mA if using Dial Capture)
General purpose inputs and outputs
Sixteen general purpose alarm inputs (Logic High =
+3.5 V to +30 V/Logic Low = -0.5 V to +0.8 V)
Unconnected state: Logic Low
Screw terminals
Return path signalling - for confirmation at site of
opening and closing
Control output - for remote control of site devices
Line fault output - for status indication at site of
alarm signalling paths.
Configurable for 2 separate Line fault output
Line fault output configurable for zone connection
- galaxy panel
Size and weight of unit
119 mm X 158 mm X 28 mm, 370 g
Order Code:
SOLO
09/15
Redcare Solo GPRS Unit
5
Signalling
Redcare
RedCare 5g STU 11 pin
Features:
Network compliant, meaning your product
will continue to work as BT upgrades the UK
telephone network. Secure’s
GPRS wireless network provides 99.7%
availability.
PD6662: 2004 scheme for EN standards in I&HAS
EN50131-1: Alarm systems. Intrusion systems
EN security standards. Environmental Class II
Compliant for interface to fire alarm panels
REN value 0.1
The 5th Generation Subscribers Terminal Unit (5G
STU) is a communicator for signalling alarm signals
between a protected premises and an Alarm
receiving centre (ARC).
The 5G STU uses the extremely reliable BT redcare
network to convey the messages over a redcare
enabled BT analogue PSTN line. Even if an intruder
cuts the line and jams the radio signals an alarm
message will still rapidly be sent to the ARC.
The 5G STU is fully compatible with BT’s 21CN
network upgrade program and connects to any BT
redcare enabled telephone line. The 5G STU is fully
ADSL compliant and does not require an additional
ADSL microfilter.
The STU has 11 screw terminal inputs plus tamper
(T) & AC fail (F) for connection to the monitored
equipment such as an alarm panel. (3 inputs on the
Fire STU) (Note on GSM STU pin 8 is reserved for
low signal strength, and pin 10 & 11 maybe reserved
for path test alarms in BSIA mode (F7=3) The alarm
inputs are triggered by changing their voltage state.
Technical Specifications:
Pin alarm inputs:
Logic High
+2.5 V to +30 V
Logic Low
-0.5 V to +0.8 V
Logic level outputs:
Logic High
3.0 V @ 560 mA max
Logic Low
0.4 V @ 280 mA max
With respect to the 0V terminal on TB1.
Power Rating:
5G GSM 12 Vdc 160 mA mean 350 mA peak
5G Classic 12 Vdc 80 mA
5G Fire 24 Vdc xx mA
Environmental:
Operating ambient temperature
+5°C to +40°C
Relay contacts:
30 V 1 A Max
Physical
Size 168 x 115 x 36 mm
Order Codes:
5G-STU
7525
608.009.171
608.009.188
WHITESTICK
EXT-CABLE
09/15
11 pin STU
Prom for 3GTSU, PakNet
and Scantronic digital
communicators
Versus Modem
Compatibility Device MCD
46801 Interface
GSM STU 5 metre
extension antenna for use
with 608.009.187
WHITESTICK extension
aerial
10 metre extension cable
6
Signalling
Redcare
RedCare 5G-GSM
Features:
Ideal for Businesses and Residential
EN501331 Grade 4
Continuous Monitoring
Two signalling paths, PSTN & GSM
Roaming SIM
RedCARE GSM is a combined PSTN Subscriber
Terminal Unit and wireless alarm reporting device
for the BT RedCARE service.
This STU is to be used for new installations but can
be used for old control panels as replacements, as
it incorporates backward compatibility. BT Redcare
GSM has an ATS rating of 5 as per table 11 of
“prEN50131-1 2004 for the primary path and ATS
rating of 4 for the radio path and complies with the
requirements of PD6662:2004.
The RedCARE GSM system is designed to provide
a backup communications path for the single land
line connection to a premises. This allows alarms
to continue to be transmitted even in the event
of a land line communications failure. The Alarm
Receiving Centre (ARC) will be able to continue to
monitor a premises following a land line failure. It
also allows line faults (as distinct from malicious line
cuts) to be more positively identified. A malicious
line cut will usually be accompanied by an intruder
alarm transmitted over the GSM path.
In addition, the GSM signal strength is constantly
monitored. Should this fall below a certain level
then a GSM alarm will be transmitted via the
landline. This means that both landline and GSM
are constantly monitored and a failure of one will
transmit an alarm via the other.
Siting
When surveying the site please remember that the
RedCARE GSM unit operates in a similar way to an
ordinary mobile telephone, therefore any restrictions
on the use of mobile telephones in the area will also
apply to the RedCARE GSM unit. Premises such as
hospitals, petrol stations, airports, blasting areas
etc... may operate mobile telephone restriction in
certain areas.
Always check that the chosen site is free of such
restrictions and advise the end user so that they are
aware, should any come into force in the future.
Technical Specifications:
Dimensions:
Power:
Inputs:
Comms Triggers:
Operating Temp:
12 Vdc, + VE removed in Alarm
-10 ° to 55 °C
Order Codes:
5G-GSM-ROAM
608.009.188
WHITESTICK
EXT-CABLE
09/15
H XW X D
308 x 383 x 95 mm
(not including Aerial 230 Vac)
Redcare Classic GSM 11pin
stu with Roaming SIM.
GSM STU 5 metre
extension antenna for use
with 608.009.187
WHITESTICK extension
aerial
10 metre extension cable
7
Signalling
Dualcom
CSL DualCom - GPRS Grade 4 (Gradeshift)
Features:
Multiple signalling paths, GPRS, telephone and/or
IP/TCIP (Internet, broadband or LAN connectivity)
High-speed signalling on GPRS path
Dual signalling is preferred by
Insurance companies and Police
Meets all insurance grades (low to high risk)
GradeShift® to remotely up/down grade for
increased insurance specification
No need for dedicated telephone line, can share
with existing telephone line or network
Reports signalling path failure in seconds
Supplied fully programmed
Comes with world SIM
DualCom GPRS is an advanced auto-dialling Digital
Communication Device for secure alarm reporting.
It is supplied as a “dual path” Alarm Transmission
System (ATS) that when fully installed will meet
Grade 2, 3, or 4 installations as specified in the
EN50136 standard for ATS.
Order Code:
CS2412
CSL Dualcom GPRS Grade
4..comes with world SIM
DualCom GPRS can transmit alarm signals to an
Alarm Receiving Centre via the radio GPRS path, the
radio GSM path, the customer’s wired LAN network
(IP) in connection with the internet, and the PSTN
(Public Switched Telephone Network).
09/15
8
Signalling
Dualcom
CSL DualCom - GPRS Grade 4 (Gradeshift)
Features
Priority Polling™
Gemini Callback®
21CN-MODE®
GradeShift® - Remote Grade Change up or down
Variable Voltage Input VVI – will accept 9v to 30v DC power
GSM Secondary Reporting Path
Managed Network
Insurance Specified
Memory Log (keeps a record of the last 96 hrs of call traffic on-board the
DualCom)
Free PSTN calls for polling and alarms
Polling Times
Fault reporting when any path
fails
G2
G3
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes
N/A Yes
-------- ------Yes Yes
G4
GFIRE
Yes
-------Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
96 hrs 96 hrs
Yes
Yes
Radio GSM/GPRS Path
G2
3 mins
G3
3 mins
G4
3 mins
GFire
3 mins
Landline/IP Path
99 secs
99 secs
99 secs 99 secs
Polling Frequency on the Radio path when PSTN and/or IP has failed 5 hrs
15 mins* 3 mins 3 mins
Fault reporting if both paths fail simultaneously
n/a
5 mins* 3 mins 3 mins
Fault reporting if both paths fail simultaneously
24 hrs 1 hr
3 mins 3mins
* Average 10 – 20 mins expected. Note 1: Values shown are for alarm reporting, polling and system integrity alerts. Note 2: Grade
4 has Priority Polling™ on both paths. Note 3: The Primary and Secondary paths can be any combination of GPRS/PSTN/IP/GSM.
Note 4: All values show the maximum specification possible from each technology.
09/15
9
Signalling
Dualcom
DualCom GPRS Grade 3
Features:
Two signalling paths, GPRS and telephone
High-speed transmission on GPRS world SIM-UK
Only
Fixed tariff means unlimited transmissions and no
hidden charges
Dual-signalling preferred by insurance companies
and police
Meets insurance Grades 2 & 3 (medium-high risk
category)
Can connect to any telephone network
No need for dedicated telephone line, can share
with existing telephone line
Reports telephone or GPRS failure in seconds
Signalling Changes
DualCom GPRS, from CSL DualCom Limited, is
an intruder alarm signalling device that uses both
the Vodafone network and your telephone path to
transmit intruder and personal attack signals at high
speed. Once the alarm is confirmed as genuine,
police are notified. Utilising two signalling paths
ensures that DualCom dual-signalling will always
have a back-up path in the event of an accidental or
deliberate fault on either path.
Dual-Signalling
DualCom GPRS is the newest member of the tried
and tested DualCom family. GPRS is a high-speed
technology used to send and receive ‘packets’ of
data. CSL chose Vodafone for the integrity of its
performance in both reliability and speed.
GPRS is charged as a fixed tariff, meaning the
device can send and receive an unlimited amount
of data at no extra charge. The use of this affordable
new technology allows CSL to bring dual-signalling
to a market previously using single-path technology
on a cost basis. Dual-signalling, as favoured by
insurance and police, is the only way forward
when it comes to the protection of people and
property.
DualCom GPRS
A dual-signalling device helps to distinguish genuine
from false alarms and can therefore prevent your
police response time from dropping to a lower level
or being withdrawn. It also allows you to gain instant
reinstatement of your Police response should it have
been withdrawn.
Additional Option With the addition of a LAN (Local
Area Network) card, DualCom GPRS can convert to
an IP (Internet) based secondary path. And, if you’re
not convinced that the internet is the way forward
for your business or you are simply not ready, it can
be plugged on at a later date whilst running on the
proven signalling paths of telephone line and GPRS
in the interim.
Order Codes:
CS2312
CS2351-00
CS2056
CSL Dualcom Grade 3
GPRS with world SIM UK
only
9 to 16 Channel Expander
Card
CSL 5M extension lead for
Dualcom GPRS units
Additional Equipment required PSU and Battery
09/15
10
Signalling
Dualcom
DualCom GPRS Grade 2
Features:
Grade 2 Dualcom GPRS unit from CSL (CS2322-00)
is an intruder alarm signalling device that uses both
the Vodafone network and the telephone path to
transmit intruder and personal attack signals at high
speed. Once the alarm is confirmed as genuine,
police are notified.
Two signalling paths, GPRS and telephone
High-speed transmission on GPRS world SIM-UK
Only
High-speed transmission on GPRS
Vodaphone SIM- ROI only
Fixed tariff means unlimited transmissions and no
hidden charges
Dual-signalling preferred by insurance companies
and police
Meets insurance Grade 2 (low-medium risk
category)
Remote upgrade available for increased insurance
specification
Can connect to any telephone network
No need for dedicated telephone line, can share
with existing telephone line
Reports telephone or GPRS failure in seconds
Utilising two signalling paths ensures that DualCom
dual-signalling will always have a back-up path in the Technical
event of an accidental or deliberate fault on either
Charger:
path. DualCom GPRS Grade2 is the newest member
of the tried and tested DualCom family.
Power :
Specifications Cont.
GPRS is a high-speed technology used to send and
Aerial connector:
receive ‘packets’ of data. CSL chose Vodafone for
the integrity of its performance in both reliability and
Order Codes:
speed. GPRS is charged as a fixed tariff, meaning
the device can send and receive an unlimited
CS2212
amount of data at no extra charge. The use of this
affordable new technology allows us to bring dual
signalling to a market previously using single-path
CS2366
technology on a cost basis.
CS2056
Technical Specifications:
CS2366 Radio Test Set Technical Specifications
Dimensions:
(h x w x d)
135 x 78 x 33 mm (215 mm
high with supplied aerial)
Weight:
210 grammes (includes aerial)
Temperature:
-20C to +60C transit,
-4C to +40C
operating
Battery:
4 volt, 500 mA/h Solid
Electrolyte
Lithium Ion
09/15
CS2322-IRE
3RD-PARTY-W-SIM
Nokia Type ACP-12X or
alternative
Mains 50mA (operation &
battery recharging)
SMA
CSL Dualcom Grade 2
GPRS with world SIM…UK
Only
CSL GPRS Radio Test Set
CSL 5M extension lead for
Dualcom GPRS units
CSL Dualcom grade 2 GPRS
with Vodaphone SIM - ROI
Only
World roaming sim
designed for use with
third party GPRS signalling
devices other than CSL
Dualcoms. CSL part
CS2394 World roaming SIM
that covers, ORANGE,
VODAPHONE, O2 and
TMOBILE networks
11
Signalling
Dualcom
CSL Signal Test
Features:
Lightweight
May be used to identify sources of interference
Remote operation for up to 12 hours
The CS2366 is a Radio Test Set for use with GSM
and GPRS Radio Networks.
Technical Specifications:
Dimensions:
The Test Set will measure and display radio signal
strength received, plus levels of received of
Weight:
interference. With the supplied aerial, it may be
Temperature:
used to measure surrounding GSM and GPRS base
stations and to aid positioning of GSM and GPRS
aerial systems, in addition, it may be used to identify
Battery:
sources of interference.
The supplied aerial may be removed to allow
performance testing of other aerial systems.
Settings allow the measurement and display of all
available GSM and GPRS networks. Alternatively,
the Test Set can be ‘locked’ to one network only.
Charger:
Power :
Aerial connector:
The Test Set contains a battery allowing remote
operation for up to 12 hours. The internal battery
may be recharged from the supplied mains power
supply.
(h x w x d) 135 x 78 x33 mm
(215 mm high with supplied
aerial)
210 grammes (includes aerial)
-20C to +60C transit, -4C to
+40C
operating
4 volt, 500 mA/h Solid
Electrolyte
Lithium Ion
Nokia Type ACP-12X or
alternative
Mains 50 mA (operation &
battery recharging)
SMA
Order Code:
CS2366
CSL GPRS Radio Test Set
If the Test Set is left switched on and unused, the
unit will automatically switch off after a preset time.
The Test Set is contained within a strong protective
sleeve and is supplied complete with a charger,
aerial and manual.
For further information,
contact CSL:CSL Dualcom Limited
Salamander Quay West
Park Lane
HAREFIELD
Middlesex
UB9 6NZ
Tel: 01895 474 474
09/15
12
Signalling
Dualcom
DigiPlus®
Features:
DigiSolo® and DigiPlus® are essentially the same
product – the new version of DigiSolo® is able to
convert and upgrade to a DigiPlus® either from
the point of purchase or at any point in the future.
Every DigiSolo® is connected to DualCom’s Gemini
managed network free of charge but is not enabled
with the features of DigiPlus® until activated.
The DigiSolo®/DigiPlus® single hardware platform
was developed in conjunction with Vodafone to fit
between any existing digital communicator and the
telephone line providing an improved and robust
signalling solution. It is guaranteed to make all
existing digital communicators fully compatible with
NGNs and BT’s new 21st Century Network (21CN)
as it uses a 300 baud modem. The sole purpose
of DigiSolo® is to provide immunity for NGN/21CN
round-trip issues. In addition DigiPlus® guarantees
compatibility and provides a fixed cost solution to
varying non-geographical telephone number rates
used by most UK Alarm Receiving Centres by using
0800 free telephone calls for all alarm and polling
traffic. DigiSolo® can be upgraded to a DigiPlus®
remotely by your ARC for an additional monthly
payment – this payment can be offset by your
Customers’ saving on telephone charges.
Guaranteed to make all digital communicators
NGN and 21CN compatible
Simple to fit in less than 5 minutes and supplied
ready programmed
No need to change/reprogram/adjust existing
digital communicator
More robust administration structure for older
digital communicators
Can use any telephone line from any provider
Will not affect or be affected by other telephone
equipment
Solution
DigiSolo® and DigiPlus® provide an invaluable
solution to the issues created by the current upgrade
of the UK’s telephone network from analogue
switched circuit (PSTN) technology to digital Internet
Protocol (IP) technology. The new Networks are
known as Next Generation Networks the biggest of
these being BT’s 21st Century Network. In total BT
plan to have upgraded 40% of its Network by 2012 –
that’s 10 million premises! NGNs could affect many
intruder and fire alarm systems signalling to Alarm
Receiving Centres (ARCs).
Many tens of thousands of older intruder alarm
systems that use Digital Communicators (DigiComs)
will be more seriously affected. During migration
DigiComs will experience outages of up to 30mins,
during which time no alarms will be delivered to your
ARC. This may leave end users with large telephone
bills and burden installers with outdated legacy
equipment.
Order Code:
CS2100
CSL DigiPlus
Digital Communicator
Vodafone Data
Network
Alarm Receiving
Centre
Primary DigiPlus
Polling Server
Secondary DigiPlus
Polling Server
Kilostream X25 Line
PSTN/X25
Gateway
CS2100 DigiPlus
Telephone Line
Telephone Line
Telephone
Exchange
Telephone exchange
09/15
13
Signalling
Webway
WebWay IP Signalling
Features:
WebWay Pro (MK 6) is a dual path IP signalling
service with roaming secondary path to 8 different
radio networks and 2 radio services (3G and GPRS).
Applications include network monitoring,
alarm transmission, verification using IP cameras,
UDL and ARM/D. 3 additional expansion interfaces
offer a totally future proofed solution capable of
integrating to multiple third party systems.
IP, 3G and EDGE/GPRS transmission paths.
Option 3G/PSTN configuration, IP ready.
8 radio network connections.
RS232, RS485 and TTL alarm panel data bus
interfaces and on board protocol emulations.
Fewer false alarms and key holder call outs.
Better signal penetration to buildings and harder
to jam.
Cert Alarm Approved to EN 2012 regulations from
Grade 1 to Grade 4 and UK insurance.
25 hour, 5 hour, 1 hour, 6 minute and 3 minute
reporting time options.
16 inputs, 1 optical output, 2 ground closure
outputs.
Expansion interface for modem capture, audio
and alarm panels with bespoke communications
Order Codes:
22-5005-IANN
The Communicator Pro is provided with a unique 3G
Roaming radio path. With more network paths to
roam there are fewer false alarms and unnecessary
key holder call outs.
Network monitoring with remote Re-Grade
The Communicator Pro network reporting time
is selected when the site is created and can be
remotely up or downgraded at any time. Suitable for
Grade 1, 2, 3 and 4 network monitoring.
22-5014-PUR
22-5005-IPUR
22-5049-10M
22-5049-15M
22-5054
Smart Reporting
WebWay Smart Reporting prevents unnecessary call 05-5022
outs for single path, network faults.
Advanced alarm transmission
Communicator Pro connects to the data bus of
the alarm panel emulates the manufacturers own
telecoms or IP module protocol. Send the original
Contact ID or SIA alarms. User codes, zones, areas,
alarm type and site specific text all transmitted.
05-5023
WebWay IP/GPRS LPS
I&HAS ATS5
WebWay IP-Digi PUR
Webway IP/GPRS LPS
I&HAS ATS5 purchased
Extension antenna with
10 m cable specified at
order
Extension antenna with
15 m cable specified
at order Smart Disc
Engineers pack Local signal
improvement antenna,
0.5 m cable
10 meter ethernet cable
Alternative cable length
requirement for special
projects
20 meter ethernet cable
Alternative cable length
requirement for special
projects
Alarm verification
Communicator Pro verifies events such as intruder
and panic or specific open/close areas/zones. IP
cameras are associated to event types and the Arm/
Disarm status of the system.
09/15
14
Signalling
Webway
WebWay
Encryption
AES128.
Key change every 24 hours for each device.
On board applications
Network monitoring.
Alarm transmission (Contact ID or SIA)
Image verification of alarms.
UDL and ARM remote panel servicing*.
IP signalling path
Any network provider.
Grade 1, 2, 3 or 4
25h, 5h, 1h & 3m reporting times.
Supports DHCP and Fixed IP.
Radio signalling path (Any)
3G/GPRS signalling module.
Micro SIM with fixed IP address.
Automatically selects provider.
Automatically selects 3G or GPRS service.
Delivered over the private network.
Grade 1, 2, 3 or 4.
Inputs and outputs
3 optical isolated output.
12 input pins
Dedicated tamper, battery and mains fail.
Expansion
3 expansion interfaces available for:
WebWay Pins - 16 inputs pins (up to 60 avail.)
WebWay Modem Capture.
WebWay Audio Verification.
WebWay RS232 Data interface
Design
Dimensions (mm) W88 x L152 x H15.
Power consumption 60mA at 12V.
Processor speed 400Mhz.
On board memory 128MBytes.
PSTN signalling path (3G/PSTN)
Any network provider.
Freephone alarms (UK).
Grade 1, 2, 3 or 4
50h, 25h, 5h, 1h, 6m reporting times.
Grade 4 to be installed on a dedicated line.
09/15
15
Signalling
Digital Communicator
DigiCom 2
Features:
The DigiCom2 is an advanced auto-dialing digital
communicator for alarm reporting. It can transmit
alarm signals to an Alarm Receiving Centre via
the analogue PSTN (Public Switched Telephone
Network) using the ‘DTMF Fast Format’ protocol.
The DigiCom2 has 8 alarm inputs. When triggered
by the alarm system, it initiates calls to the Alarm
Receiving Centre (ARC).
The DigiCom2 is housed in an ABS plastic case
which protects the electronics.
Order Codes:
D1110
D1154
D1055
09823uk-00
09/15
Dycon Digicom2, 8
channel standalone digital
communicator
Chip programmer with CD
and USB cable (available via
NSL)
NVM chip (available via NSL)
Cooper Sec box of 10
communicator NVM chips
Built-in Abort function to enable older alarm
systems to comply with the ACPO false alarm
policy.
Provides robust Fast Format which is resilient to
delays introduced by next generation networks
Monitors the PSTN line continuously - if a fault
occurs, a message will be sent to the control
panel.
In case of a misoperation when the system is
set, and the system is unset within 90 seconds, a
“Restore on
Channel 3”, or separate, code will be sent to the
Alarm
Receiving Centre.
8 alarm inputs – when Triggered by the alarm
system, the DigiCom2 initiates calls to the Alarm
Receiving Centre.
Built-in relay for serial handset connection
Three way calling to override engaged Telephone
line.
NVM re-usable
Technical Specifications:
Model:
Dimensions:
Weight:
Telephone:
D1110 Stand Alone
(h x w x d) 19 x 61 x 91 mm
80 grams
Path Standard PSTN
technology
Abort Facility Built-in:
Power Requirement: Max 13.8v Min 9.0v DC,
0.1volt max ripple
Current Consumption:
6 mA quiescent, 20 mA
operating
Low Battery:
10.9-11.1 volts falling, 11.912.1v recovery
Outputs:
1 Aux relay (24v 1A contacts)
Start Inputs:
Max +15 volt, Min +3.5 volts
DC
Temperature:
-20°C to +60°C transit, -4°C to
+5°0C operating
Humidity:
0 - 80% non-condensing
16
Signalling
Voice Dialler
GJD Voice Dialler
Features:
When your burglar alarm goes off the reality is that
in most situations it is ignored. Many people view
the alarm siren as a nuisance and do not call the
police or bother to investigate. The GJD Voice Dialler
offers a solution.
The GJD Voice Dialler is the ideal companion for
virtually any alarm control panel as it provides
additional protection, rather than relying on the
outside bell to attract attention.
When the alarm is triggered, the Voice Dialler
will ring a combination of nine different numbers
(including mobile phones) to alert people you know
and trust so they can investigate appropriately.
The unit stores up to two pre-recorded messages
which can be used to warn of two different
situations, e.g. burglary, personal attack, fire etc.
These are specific to your alarm system and can be
changed as often as desired.
Built-in Abort function to enable older alarm
systems to comply with the ACPO false alarm
policy.
Provides robust Fast Format which is resilient to
delays introduced by next generation networks
Monitors the PSTN line continuously - if a fault
occurs, a message will be sent to the control
panel.
In case of a misoperation when the system is
set, and the system is unset within 90 seconds, a
“Restore on
Channel 3”, or separate, code will be sent to the
Alarm
Receiving Centre.
8 alarm inputs – when Triggered by the alarm
system, the DigiCom2 initiates calls to the Alarm
Receiving Centre.
Built-in relay for serial handset connection
Three way calling to override engaged Telephone
line.
NVM re-usable
The Voice Dialler is simple to operate with clear
on screen instructions guiding the user through
programming messages and telephone numbers.
Recording a message is easy as the has a built in
microphone and speaker so that phrases can be
recorded and replayed directly into the unit.
When the outgoing call is answered the Voice Dialler
plays a common phrase which normally states your
name and address and one of the phrases relating
to the inputs from the control panel (PA, burglary,
fire and auxiliary in our example).
Order Code:
GJDHYL004
GJD voice dialler
The Voice Dialler is connected between the alarm
control panel and the telephone line. It behaves
like another extension to the telephone and does
not affect the normal operation or that of any other
extensions fitted. However, if the Voice Dialler is
operating, the messages will be heard if any hand
set is lifted. it requires no batteries as its power is
derived from the alarm control panel.
09/15
17
Sounders
This chapter contains information about our range of Sounders
Introduction
Hex 7422 G3F External Sounder
Rapier Stainless Steel Sounder
Klaxon Duplo High Output Sirens
Internal Sirens
08/16
1
Sounders
Introduction
High efficiency electronic modules providing
maximum sound output with minimum current
demand from the control panel in standby and alarm
conditions, which means your control panel has
more capacity for other devices such as PIR’s etc.
These Internal & external sounders are constructed
of robust poly carbonate or stainless steel with
options for inner steel covers and back plates if
required. All electronics modules are conformably
coated to protect them from harsh external
environments.
Internal sirens operate both as an early deterrent to
intruders and as a method of indicating changes in
system status to property occupants. Most of these
are small aesthetically pleasing and having a low
profile designs with alternate tones to use.
08/16
Typical features of some external sounders include
options of single or twin piezo, high power strobe
and engineer mode for silent start up. Grade 3
External siren models also include: Ring Line
Monitoring, Self Test of internal battery and piezo,
Remote Test Input, Fault Output, Audible Tamper
operation on commissioning and choice of Four
Tones.(Check model for individual specification)
All UK sounders are suitable for use in systems
designed to comply with BS EN 50131-4:2009 /
PD6662:2010 at Grade 2,3 or 4 as specified and
Environmental Class IV, providing full weather
protection to the internal electronics module.
2
Sounders
External Sounders
7422-G3F External Sounder
Features:
High Efficiency Operation
-15 mA standby,
-180 mA sounding
Low Current LED Strobe
Comfort LEDs
Selectable Sound Cut-off Timer
Ring Line Monitoring
Battery Quality Test with Fault Output
Remote Test Input
Silent Engineer Start-up
Integral EOL Tamper Resistors
Audible Tamper to Assist Commissioning
Full SAB Capability
The 7422-G3F sounder is a high specification
external warning device for use in intruder hold-up
alarm systems, fully meeting the requirements for
EN50131-4 at Security Grade 3 and Environmental
Class IV.
Operation
The 7422-G3F will detect any attempt to gain
unauthorised access to the sounder by removal of
the cover, or any attempt to remove it away from its
mounting surface. This will generate a tamper signal
which is normally fed back to the alarm control
panel. Integrity of the Trigger Command (Ring Line)
connection is constantly monitored and will
cause the unit to self activate and report a tamper to
the control panel if loss of connection is detected.
The 7422-G3F is classified a self powered sounder
and has an on-board battery which is recharged
via the external power source. This battery is used
to operate the sounder if the external power is
removed. The 7422-G3F will self actuate in the event
that a tamper condition is detected or the external
power to the sounder is removed.
Technical Specifications:
Sound Output
105 dB(A) peak @ 1 m
Modulated tone. Power Supply
9.0 – 15.0 Vdc,13.8 Vdc
nominal
Current Consumption 10 mA at 13.8vdc (quiescent)
Battery charging
26 mA when charging fully
discharged batteries
Sounding
180 mA max
Strobe
40 mA max
Cut-off Timer
Selectable 5s, 10 min, 15min
Dimensions with cover
on (mm)
322W x 317 H x 80D
08/16
Battery
6 V 320 mAh NiMH - Battery
recharge in less than 24 hours
(Following 2 x 15 minute
sounding)
Battery Low Voltage Detection
5.3 V ±0.2 V
Strobe
LED, 1Hz flash rate reducing to
0.5 Hz after 15 minutes
Tamper
Cover and Rear
Tamper Output
Volt free contact, maximum
16O hms resistance
Max 100 mA current rating
Fault Output
Volt free contact, maximum
16Ohms resistance
Max 100 mA current rating
Sound Trigger Input R- < 3.5Vdc = sound ON R- >
8.5 Vdc = sound OFF
0.3 mA max
Strobe Trigger Input ST- < 6.5 Vdc = strobe flash
ON ST- > 6.6 Vdc = strobe OFF
1.5 mA max
Cover & Lens Material
Poly carbonate
Operating Temperature
- 25oC to +60oC
Storage Temperature - 25oC to +70oC
Order Codes:
7422-G3F
7423-E
7423-DUM-LED
7423-DUM-BRKT
7422-G3-BAT
Elmdene Grade 3 ADT Hex
ext siren kit Elmdene with
cover
ADT Ext Siren Cover for
7422-G3F
ELM LED MOD For Dummy
Cover
ELM DUM HEX Cover Brkt
ELM Replacement Battery
(NiMh) for 7422-G3F
3
Sounders
External Sounders
Rapier
Features:
Designed to meet the requirements of EN501314:2009 Grade 3 and 4
Battery and Piezo self-test with fault output
Remote test input
Ring line monitoring
Silent engineer mode
Can be mounted portrait or landscape
Audible tamper closure to assist commissioning
LED strobe
Drill detection (G4S model only)
The Rapier range of high quality, external sounders
has been upgraded to fully meet the requirements
of the new sounder standard EN50131-4:2009
Grade 3 and 4. They also include a host of new and
improved features in addition to the introduction of
chrome plated plastic covered versions.
The sounders now include a diagnostic LED which
will flash to indicate problems with the sounder,
versatile trigger options and comfort LEDs to signal
that the device is working. Control panel dependent
end of line resistors also help make installation
easier.
The Rapier sounders can be mounted in portrait or
landscape orientation, giving real flexibility. This is
now made easier with the inclusion of two internal
spirit levels.
Technical Specifications:
Sound Output
105dB(A) peak @ 1 m
Modulated tone. Power Supply
9.0 – 15.0 Vdc,13.8 Vdc
nominal
Current Consumption
10 mA at 13.8 Vdc (quiescent)
Battery charging
26 mA when charging fully
discharged batteries
Sounding
180 mA max
Strobe
40 mA max
Cut-off Timer
Selectable 5s, 10min, 15 min
Battery
6 V 320 mAh NiMH - Battery
recharge in less than 24 hours
(Following 2 x 15 minute
sounding)
Order Codes:
The stainless steel cover’s clean lines gives a smart
and aesthetically-pleasing look to the unit.
RAPIER-G4S
RAPIER-G3S-ADT
7632
SIREN-BACK-PLATE
08/16
ELM Hi Security stainless
steel ext siren
Rapier 6000 Stainless Steel
siren ADT logo
Rapier Stainless Dummy
Siren when using Dummy
sirens
Aluminium mounting plate
for external siren. The
mounting plate is made
from 3 mm Aluminium and
measures 350 mm x
350 mm
4
Sounders
External Sounders
High Output Sounders Klaxon Duplo High Output
Siren
Features:
High Output
Mains Powered
IP67 Rated
Klaxon Duplo High Power Siren
The Duplo is a powerful weatherproof motor driven
siren producing a clear, distinctive note suitable for
use in fire, security and general industrial use.
Secomac Master Blaster External Siren
Master Blaster is the most powerful security siren
of its type available. Mains powered but triggered
by a 12 V relay. It has a sound output of 127 dB at 1
metre. The unit has a weatherproof ABS body and
comes pre-wired with 1 m cable.
Technical Specifications:
Klaxon Duplo High Power Siren
Voltage:
2 Vdc - 15.0A
24 Vdc
- 8.3 A
110 Vac
- 2.0 A
230 Vac
- 1.0 A
Audibility:
126 dB at 1 metre
Frequency:
1500 Hz
Rating:
On 15 mins, off 10 mins
Weight:
2.04 Kg
Case Material:
Aluminium Alloy LM25
Colour:
Grey/Black
Secomac Master Blaster External Siren
Weight:
1.8 Kg
Voltage:
110 Vac, 2.7 A
Audibility:
127 dB at 1 metre
Frequency:
1680 Hz
Rating:
Continuous
Colour:
Yellow
Order Codes:
7622
6143
08/16
Master Blaster 240 V Siren
Secomac
Universal 240 V siren relay/
timer
5
Sounders
Internal Sounders
Internal Sirens
Internal sirens operate both as an early deterrent to intruders and as a method of indicating changes in
system status to property occupants.
08/16
Description
Order Codes
Extension Speaker
Extension speaker for connection to the horn output of
the Galaxy range and most Scantronic control panels.
As this unit is a speaker, when connected to the
correct alarm panel, different tones will be generated
to indicate various conditions.
7587E
Elmdene 16-Ohm extension
speaker with 1K resistor
fitted and tamper switch
SO-ALTO-WH 12V Internal Sounder.
This remotely powered sounder is intended to be
used with security alarm systems, to give an audible
and visual indication that the alarm system has been
activated.
The unit features a dynamic piezo sounder for the
audible indication. The sound output is selectable
for either alternating or continuous tone. It is also
protected against tempering by means of lid removal
and removal from the mounting surface.
SO-PICCOLO 12V Internal Sounder.
This remotely powered sounder is intended to be
used with security alarm systems, to give an audible
and visual indication that the alarm system has been
activated.
The unit features a piezo sounder and two bright
LEDS’s for audible and visual indication. The sound
output is selectable for either alternating or continuous
tone. It is also protected against tempering by means
of lid removal and removal from the mounting surface.
Soundguard
Similar to the Piezostrobe but without the visual
element. 102dB output.
SO-ALTO-WH
CQR low profile internal siren
Elmdene Self Actuating Siren
Elmdene INT401S Internal Self Actuating Siren for use
with Residential Systems.
676.002.061
Elmdene plastic boxed Grade
2 siren
Extension Speaker
Small Oval shaped Extension Speaker with Cover
Tamper
I30
Speaker
SO-PICCOLO-WB-G3
CQR low profile sounder and
blue LED strobe. Grade 3.
676.002.034
Soundguard
6
Sounders
Internal Sounders
Internal Sirens
Description
Order Codes
LED strobes
This range of low profile Beacons utilising power
efficient LED technology, available with a choice of
colour lenses in 12 V dc power models. The Beacons
are IP66, with two variants offering either a single stud
or twin M3 fixing points.
LPB12-C-T
LED Strobe 12 V DC Clear
Lens Black Base
LPB12-B-T
LED Strobe 12 V DC Blue
Lens Black Base
LPB12-A-T
LED Strobe 12 V DC Amber
Lens Black Base
Suitable for use in, intruder, access control systems or
general applications.
02/16
7
Head Office:
United Kingdom & Ireland
(Sunbury-on-Thames)
Tel: +44 800 4587 999
Fax: +44 (0) 844 800 2999
www.tycoemea.com
Issue 15.30 - 11/16
Copyright © 2016 Tyco Fire and Security. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF