UNVENTED (VENT-FREE)
LogMate™ UNIVERSAL FIREBOX
OWNER’S OPERATION AND INSTALLATION MANUAL
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
®
FB36NCA and FB42NC
Non-circulating Models
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury, or loss
of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
,,
FB36CA and FB42C
Circulating Models
WARNING: Improper installation, adjustment, alteration,
service, or maintenance can
cause injury or property damage. Refer to this manual for
correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the
gas supplier.
WARNING: For use only with
decorative type unvented room
heaters. Do not build a wood fire.
This firebox has been tested
and approved by I.A.S. under
their REQ. 2-97 for use with any
ANSI Z21.11.2 approved gas
logs.
This firebox may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by
state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer (i.e. Installation of this product is permitted after the manufactured (mobile) home is sited).
Save this manual for future reference.
VANGUARD
UNVENTED (VENT-FREE) LOGMATE™ FIREBOX
SAFETY
INFORMATION
6.
WARNINGS
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate, or service this firebox. Improper use of this firebox can
cause serious injury or death from
burns, fire, explosion, electrical
shock, or carbon monoxide poisoning.
CAUTION: Carefully review
the instructions supplied with the
decorative type unvented room
heater for the minimum fireplace
size requirement. Do not install
the appliance in this firebox unless this firebox meets the minimum dimensions required for the
installation.
7.
8.
9.
10.
11.
WARNING: Any change to
this firebox or its controls can be
dangerous.
1.
2.
3.
4.
5.
This firebox shall not be installed in a
bedroom or bathroom.
Never install the firebox
• in a recreational vehicle
• where curtains, furniture, clothing, or
other flammable objects are less
than 36 inches from the front, top,
or sides of the firebox
• in high traffic areas
• in windy or drafty areas
Do not use this firebox as a wood-burning fireplace. Use only decorative
unvented room heaters (log sets).
Do not add extra logs or ornaments
such as pine cones, vermiculite, or rock
wool. Using these added items can
cause sooting.
You must operate this fireplace with the
provided fireplace screen, hood, and
brick liner in place. Make sure these
parts are in place and screens are closed
before running firebox.
12.
13.
14.
15.
16.
Do not allow fans to blow directly into
the firebox. Avoid any drafts that alter
burner flame patterns. Ceiling fans can
create drafts that alter burner flame
patterns. Altered burner patterns can
cause sooting.
Do not use a blower insert, heat exchanger insert or other accessory not
approved for use with this heater. Do
not use blower accessory with Models
FB36NCA or FB42NC. Use only the
provided hood, or appropriate polished
brass hood accessory. See Accessories
on page 13.
Vent-free gas log heaters installed in
these fireboxes require fresh air ventilation to run properly. See Air for Combustion and Ventilation, pages 4
through 6.
Do not run firebox
• where flammable liquids or vapors
are used or stored
• under dusty conditions
Do not use this firebox to cook food or
burn paper or other objects.
Never place any objects in the firebox
or on logs.
Firebox front and screen becomes very
hot when running firebox. Keep children and adults away from hot surfaces
to avoid burns or clothing ignition. Firebox will remain hot for a time after
shut-down. Allow surfaces to cool before touching.
Carefully supervise young children
when they are in the room with firebox.
Turn firebox off and let cool before
servicing. Only a qualified service person should service and repair firebox.
Operating firebox above elevations of
4,500 feet could cause pilot outage.
Do not use the firebox if it has been
under water due to the shock hazard
that could result with the blower accessary (if installed) in place.
2
LOCAL CODES
Install and use fireplace with care. Follow
all local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code ANSI Z223.1, also known as
NFPA 54*. Firebox must be electrically
grounded in accordance with the National
Electrical Code, ANSI/NFPA70 (latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
1.
2.
3.
4.
Use utility knife to cut carton all the
way around above the staples on the
bottom tray. Lift carton off the firebox
and discard.
Remove all protective packaging from
inside firebox. Carefully lift the firebox off the bottom corrugated tray.
Check carton contents for the
following:
• Screen assembly
• Screen support rod
• Hardware and parts bag containing
the following:
- Owners Operation and Installation
Manual
- 2 - Black #10 x 3/8" Phillips
screws for mounting screen
support rods
If any items are missing, inform dealer
where you bought firebox.
Check all items for any shipping damage. If damaged, promptly inform
dealer where you bought firebox.
Notice: The firebox identification
label (including model number,
serial number, clearances, etc.)
is located either on the left front
edge of the firebox or behind the
left side firebrick panel. See Figure 15, page 10.
103451
OWNER’S MANUAL
PRODUCT
SPECIFICATIONS
41 11/16" (36" models) • 47 11/16" (42" models)
Standoffs (Models FB36NCA
and FB42NC only)
2 5/8"
35"
19 3/8"
Built-in Nailing
Flanges
15 7/8"
36" (36" models) • 42" (42" models)
2 5/8"
Louvers
(Models FB36CA
and FB42C only)
6 5/8"
Figure 1 - Firebox Front View
Standoffs (Models FB36NCA and FB42NC only)
2 3/4"
29 1/8" (36" Models) • 35 1/8" (42" Models)
1 1/2"
8 7/16"
Electrical Access
Hole
(for use when
using blower
power cord with
external electrical
outlet. See
Blower Kit
Gas Line Access
Instructions)
Hole (either side)
19 1/2"
22 1/4"
5/8"
30 3/8" (36" Models) • 36 7/8" (42" Models)
36" (36" Models) • 42" (42" Models)
41" (36" Models) • 47" (42" Models)
42 3/8" (36" Models) • 48 3/8" (42" Models)
6 7/8"
Figure 3 - Firebox Top View
1 1/2"
Diameter Holes
9 5/8"
3 1/2"
10 3/4"
13 9/16"
Figure 2 - Firebox Side View
103451
Electrical Access Hole
Strain relief fitting for electrical cable when hard
wiring firebox for built-in installations (strain relief
fitting included on circulating models only)
3
VANGUARD
UNVENTED (VENT-FREE) LOGMATE™ FIREBOX
PRODUCT
FEATURES
Operation
This firebox is designed for use with approved ANSI Z21.11.2 decorative type
unvented room heaters. (Physical size limitations apply. Refer to minimum firebox
requirements supplied with log heater.) It
requires no outside venting or chimney making installation easy and inexpensive. When
used without the blower (models FB36CA
or FB42C only), the firebox requires no
electricity making it ideal for emergency
back-up heat.
Blower Accessory
The FB36CA or FB42C fireboxes will accept the GA3700 accessory. The variable
blower allows you to select the fan speed
you desire. The blower circulates heated air
from the firebox into the room. Use of
blower is optional.
Brick Liner
This firebox features a revolutionary lightweight concrete brick liner. As with all
concrete liners, this liner may develop slight
cracks when exposed to heat. These cracks
will not affect the performance of the fireplace or vent-free gas logs.
LOCATING
FIREBOX
Planning
Plan where you will install the firebox. This
will save time and money later when you
install the firebox. Before installation, consider the following:
1. Where the firebox will be located. Allow for wall and ceiling clearances (see
Installation Clearances, page 7).
2. Everything needed to complete installation.
3. These models CANNOT be installed
in a bedroom or bathroom.
4. Proper air for combustion and ventilation (see below).
AIR FOR
COMBUSTION AND
VENTILATION
WARNING: This firebox shall
not be installed in a confined
space unless provisions are provided for adequate combustion
and ventilation air. Read the following instructions to insure
proper fresh air for this and other
fuel-burning appliances in your
home.
Today’s homes are built more energy efficient than ever. New materials, increased
insulation, and new construction methods
help reduce heat loss in homes. Home owners weather strip and caulk around windows
and doors to keep the cold air out and the
warm air in. During heating months, home
owners want their homes as airtight as possible.
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireboxes, clothes dryers, and
fuel burning appliances draw air from the
house to operate. You must provide adequate fresh air for these appliances. This
will insure proper venting of vented fuelburning appliances.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for
combustion and ventilation. However, in
buildings of unusually tight construction,
you must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the
outside atmosphere have a continuous water vapor retarder with
a rating of one perm (6 x 10-11 kg
per pa-sec-m2) or less with openings gasketed or sealed and
b. weather stripping has been
added on openable windows and
doors and
c. caulking or sealants are applied
to areas such as joints around
window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three
criteria above, you must provide additional fresh air. See Ventilation Air
From Outdoors, page 6.
If your home does not meet all of the
three criteria above, proceed to page 5.
Confined and Unconfined Space
3. Confined Space.
The National Fuel Gas Code (ANSIZ223.1,
1992 Section 5.3) defines a confined space
as a space whose volume is less than 50
cubic feet per 1,000 Btu per hour (4.8 m3 per
kw) of the aggregate input rating of all
appliances installed in that space and an
unconfined space as a space whose volume
is not less than 50 cubic feet per 1,000 Btu
per hour (4.8 m3 per kw) of the aggregate
input rating of all appliances installed in that
space. Rooms communicating directly with
the space in which the appliances are installed*, through openings not furnished
with doors, are considered a part of the
unconfined space.
The information on pages 4 through 6 will
help you classify your space and provide
adequate ventilation.
* Adjoining rooms are communicating only
if there are doorless passageways or ventilation grills between them.
PROVIDING ADEQUATE
VENTILATION
The following is exerpts from National Fuel
Gas Code. NFPA 54/ANSI Z223.1, Section
5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classifications:
1. Unusually Tight Contruction;
2. Unconfined Space;
Continued
4
103451
OWNER’S MANUAL
AIR FOR
COMBUSTION AND
VENTILATION
Continued
DETERMINING AIR FLOW FOR FIREBOX LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install firebox plus any adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height = ________cu. ft. (volume of space)
Example: Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of
the space.
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
_____________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example: 3168 cu. ft. (volume of space) ÷ 50 cu. ft. = 63.3 or 63,300 (maximum Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free firebox
____________ Btu/Hr
Example:
Gas water heater*
____________ Btu/Hr
Gas water heater
40,000 Btu/Hr
Gas furnace
____________ Btu/Hr
Vent-free firebox
Vented gas heater
____________ Btu/Hr
with log heater
+
39,000 Btu/Hr
Gas firebox logs
____________ Btu/Hr
Total
=
79,000 Btu/Hr
Other gas appliances* + ____________ Btu/Hr
Total
= ____________ Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
______________ Btu/Hr (maximum the space can support)
______________ Btu/Hr (actual amount of Btu/Hr used)
Example: 63,300 Btu/Hr (maximum the space can support)
79,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support.
You must provide additional fresh air. Your options are as follows:
A. Rework work sheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air from Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air from Outdoors, page 6.
C. Install a lower Btu/Hr firebox, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.
WARNING: If the area in which the firebox and gas log heater may be operated is smaller than that defined as
an unconfined space, provide adequate combustion and ventillation air by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3 or applicable local codes.
Continued
103451
5
VANGUARD
UNVENTED (VENT-FREE) LOGMATE™ FIREBOX
AIR FOR
COMBUSTION AND
VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside
Building
This fresh air would come from an adjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must provide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 4). You can also
remove door into adjoining room (see option 3, Figure 4). Follow the National Fuel
Gas Code NFPA 54/ANSI Z223.1, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
12"
Ventilation
Grills
Into Adjoining
Room,
Option 1
Ventilation Grills
Into Adjoining Room,
Option 2
Or
Remove
Door into
Adjoining
Room,
Option
3
,,,,,
,,,,
,
,
,,,,,
,,,,
,
,
,
,,,,,
,,,,
,
,
,
,
,,,,,
,
,
,,,,
,
,
,
,,,,,
,
,
,,,,
,
,
,
,,,,,
,
,
,,,,
,
,
,
,,,,,
,
,
,,,,
,
,
,,,,,
,
,
,,,,
,
,
,
,
,,,,
,,,,,,,
,
,,,,,
,,
,
12"
Figure 4 - Ventilation Air from Inside Building
WARNING: Rework worksheet, adding the space of the
adjoining unconfined space. The
combined spaces must have
enough fresh air to supply all
appliances in both spaces.
Outlet
Air
Ventilated
Attic
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two permanent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
or spaces open to the outdoors. These spaces
include attics and crawl spaces.
IMPORTANT: Do not provide openings
for inlet or outlet air into attic if attic has a
thermostat-controlled power vent. Heated
air entering the attic will activate the power
vent.
Outlet
Air
To Attic
,,,,,,,
,,,,,,,
,,,,,,,
,,,,,,,
,,,,,,,
,,,,,,,
,,,,,,,
,,,,,,,
Inlet
Air
Inlet Air
To
Crawl
Space
Ventilated
Crawl Space
Figure 5 - Ventilation Air from Outdoors
6
103451
OWNER’S MANUAL
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat. Do
not install this heater as your
primary heat source. In the event
of a power outage, you can use
this heater as your primary heat
source.
NOTICE: A qualified service person must install firebox. Follow
all local codes.
WARNING: Never install the
firebox
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the firebox
• in high traffic areas
• in windy or drafty areas
CAUTION: Log heaters installed in this firebox create warm
air currents. These currents move
heat to wall surfaces next to firebox. Installing firebox next to vinyl or cloth wall coverings or
operating firebox where impurities in the air (such as tobacco
smoke) exist, may discolor walls.
IMPORTANT: Vent-free gas log heaters
add moisture to the air. Although this is
beneficial, installing firebox in rooms without enough ventilation air may cause mildew to form from too much moisture. See
Air for Combustion and Ventilation, pages 4
through 6.
IMPORTANT: Make sure the firebox is
level. If firebox is not level, log set will not
work properly.
Note: Your Vanguard firebox is designed to
be used in zero clearance installations. Wall
or framing material can be placed against
any exterior surface on the rear, sides or top
of your firebox, except where stand-off spacers are integrally attached. If stand-off spacers are attached to your firebox, these spacers can be placed directly against wall or
framing materials. Use the dimensions
shown for rough opening to create the easiest installation.
103451
INSTALLATION
CLEARANCES
D. Clearances from the bottom of firebox
to the floor is 0 inches.
WARNING: Maintain the minimum clearances. If you can, provide greater clearances from
floor, ceiling, and adjoining wall.
These fireboxes can be installed as freestanding units against a wall with the approved, optional cabinet mantels (see Accessories, page 13) or as a built-in unit. The
clearances are the same for either installation method.
Carefully follow the instructions below. This
will ensure safe installation.
Minimum Wall and Ceiling
Clearances (see Figure 6)
CAUTION: Do not install the
firebox directly on carpet or vinyl.
A. Clearances from the side of the firebox
opening to any combustible wall should
not be less than 16 inches.
B. Clearances from the top of the firebox
opening to the ceiling should not be less
than 42 inches.
C. When the firebox is installed on carpeting or other combustible material,
other than wood flooring, the firebox
should be installed on a metal or wood
panel extending the full width and
depth of the enclosure.
Mantel Clearances for
Conventional Installation
42" to Ceiling
16"
to Side Wall
,,,,,,,
,,,,,,,
,,,,,,,
,,,,,,,
,,,,,,,
,,,,,,,
,,,,,,,
,,,,,,,
16"
to Side Wall
0" to Floor
Figure 6 - Minimum Clearance to Wall, Ceiling, and Floor
Continued
7
VANGUARD
UNVENTED (VENT-FREE) LOGMATE™ FIREBOX
INSTALLATION
Continued
Mantel Clearances for Built-In
Installation
If placing custom mantel above built-in
firebox, you must meet the minimum allowable clearance between mantel shelf and top
of firebox opening shown in Figure 7. These
are the minimum allowable mantel clearances for a safe installation. Use larger clearances wherever possible to minimize the
heating of objects and materials placed on
the mantel.
BUILT-IN FIREBOX
INSTALLATION
Built-in installation of this firebox involves
installing firebox into a framed-in enclosure. This makes the front of firebox flush
with wall. Optional brass trim accessories
are available (see Accessories, page 13).
The brass trim will extend past sides of
firebox approximately 1/2 inch.This will
cover the rough edges of the wall opening.
If installing a mantel above the firebox, you
must follow the clearances shown in Figure
7. Follow the instructions below to install
the firebox in this manner.
1. Frame in rough opening. The firebox
framing should be constructed of 2 x 4
lumber or heavier. Use dimensions in
Table 1 and rough opening layout in
Figure 8a. Adjust framing so that firebox flushes with finished wall surface.
If installing in a corner, use dimensions
in Figures 8b and 8c for rough opening.
2. Install gas piping to firebox location.
See Installing Gas Line on page 10 and
Connecting to Gas Supply in log set
owners manual.
IMPORTANT: If installing blower accessory (Models FB36CA and FB42C), see
Hard-Wiring Firebox, page 10.
10"
8"
2 1/2"
,,
,
Firebox
Note:
All vertical measurements
are from top of fireplace
hood opening to bottom
of mantel shelf. All
measurements are in
inches.
6"
Facing material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments.
Wire-mesh
Screen
CAUTION: Do not allow the
vent-free gas log heater to touch
or extend beyond the fireplace
screen.
If your installation dies not meet the above
minimum clearances in Figure 7, you must:
• raise the mantel to an acceptable height,
OR
• remove the mantel.
Mantel Shelf
Non-combustible Material
May Project Off this Surface
above the Firebox Hood
13"
16"
19"
21"
Firebox Hood
Must Be Used
at All Times
Figure 7 - Minimum Mantel Clearances for Built-In Installation
TABLE 1
ROUGH OPENING DIMENSIONS FOR BUILT-IN INSTALLATION
FRONT WIDTH
DEPTH
MODEL #
(Inside to Inside)
HEIGHT
(Minimum)
37"
20"
FB36NCA
41 1/4"
1
1
FB36CA
41 /4"
35 /2"
20"
1
37"
20"
FB42NC
47 /4"
47 1/4"
FB42C
35 1/2"
20"
FOR 36" MODELS
Height - 37" for FB36NCA
35 1/2" for FB36CA
"
32
9/
2
0-
36"
Figure 8b
5
41-1/4"
Depth
(Minimum)
72"
TOP VIEW
Height
FOR 42" MODELS
Height - 37" for FB42NCA
35 1/2" for FB42CA
"
Width
(Inside to Inside)
45°
39"
32
5/
55
Figure 8c
45°
Figure 8a
47-1/4"
78"
TOP VIEW
Figure 8 - Rough Opening for Installing in Wall
8
103451
OWNER’S MANUAL
INSTALLATION
Continued
3.
4.
5.
6.
7.
Carefully set firebox in front of rough
opening with back of firebox inside
wall opening. IMPORTANT: If installing Brass Trim Kit GA6091 or
GA6092, see instructions included with
brass trim accessory. You must install
shoulder screws from brass trim kit
now.
Carefully insert firebox into rough
opening.
Attach firebox to wall studs using nails
or wood screws through holes in nailing flange (see Figure 9).
If using optional GA6091 or GA6092
Brass Trim Kit, install the trim after final finishing and/or painting of wall.
See instructions included with brass
trim accessory for attaching brass trim.
Install and properly test gas log heater.
Follow installation instructions included with the vent-free gas log heater
that is being installed.
IMPORTANT: When finishing your firebox, combustible materials such as wall
board, gypsum board, sheet rock, drywall,
plywood, etc. may be butted up next to the
sides and top of the firebox. Combustible
materials should never overlap the firebox
front facing.
WARNING: Do not allow any
combustable materials to overlap the firebox front facing.
Nails or
Wood
Screws
Nailing
Flanges
IMPORTANT: Non-combustible materials
such as brick, tile, etc. may overlap the front
facing, but should never cover any necessary openings like louvered slots.
WARNING: Do not allow noncombustible materials to cover
any necessary openings like louvered slots.
5.
Place cabinet mantel on floor in desired
location. Make sure mantel is flush
against wall.
Break off nailing flanges with hammer
or pliers (see Figure 11).
Cabinet
Mantel
WARNING: Never modify or
cover the louvered slots on the
front of the firebox.
WARNING: Use only non-combustible mortar or adhesives
when overlapping the front facing with non-combustible facing
material.
Electrical
Outlet
INSTALLING FIREBOX USING
OPTIONAL ACCESSORY
MANTELS
NOTICE: A qualified service person must install firebox. Follow
all local codes.
This firebox may be installed using a cabinet mantel accessory against a wall in your
home. The firebox and cabinet mantel can
be installed directly on the floor. A brass
trim kit is included with the mantel accessory GM103U or GM105U (see Accessories, page 13).
1. Assemble cabinet mantel accessory and
the brass trim kit. Assembly instructions are included with each accessory.
2. If using an optional GA3700 Blower
(circulating models only), install a
properly grounded, 120 volt threeprong electrical outlet at firebox location if an outlet is not there. If possible,
locate outlet so cabinet mantel will
cover it when installed (see Figure 10).
3. Install gas piping to firebox location.
See Installing Gas Line, page 10. You
may have to cut an access hole in the
floor or wall to run gas line to firebox.
Make sure to locate access hole so cabinet mantel will cover it when installed
(see Figure 10).
Gas Line
Access Hole
(Either Side
of Firebox)
Gas
Piping
Figure 10 - Installing Cabinet Mantel
Nailing Flanges
Figure 11 - Location of Nailing Flanges
(Two on Each Side)
Continued
Figure 9 - Attaching Firebox to Wall Studs
103451
4.
9
VANGUARD
UNVENTED (VENT-FREE) LOGMATE™ FIREBOX
HARD-WIRING FIREBOX
INSTALLATION
Continued
6.
7.
8.
9.
Install the brass trim kit furnished with
mantel. See instruction sheet included
with the mantel now.
If installing the optional GA3700
Blower (circulating models only), see
instruction sheet included with blower
now.
Carefully insert firebox into cabinet
mantel. Be careful not to scratch firebox, cabinet mantel, flooring, etc. when
installing (see Figure 12).
Install and properly test gas log heater.
Follow installation instructions included with the vent-free gas log heater
that is being installed.
Manual
Shutoff
Valves
(Install
One)
Knockout Locations
(Knock Out One Hole)
Gas Line Hole
Figure 13 - Installing Gas Line and Manual
Shutoff Valve
,
Locate the recessed knockout in one of the
firebrick sidewall liners (see Figures 13 and
14). Firmly tap the center of the knockout
with a chisel until it is released. Carefully
chisel the rough edges of the hole you have
made to smooth edges. This hole will line up
with the hole in the outer casing.
CAUTION: Do not use excessive force to remove the knockout. Too much force may damage the firebrick concrete insert.
For Built-in Installation of
Circulating Models Only
Models FB36CA and FB42C can be hardwired to the duplex outlet located inside the
firebox bottom if desired. This allows the
GA3700 Blower Accessory to be plugged
into the duplex outlet.
NOTICE: A qualified electrician
must connect electrical wiring to
duplex outlet for built-in installation. Follow all local codes. In
absence of local codes follow The
National Electric Code ANSI/
NFPA 70.
1.
Using Phillips screwdriver, remove the
screw and retainer bracket at the top of
the firebrick liner panel on the left side.
Carefully remove the left panel from
the firebox. Repeat for firebrick liner
panel on right side.
Left Side Firebrick Liner Panel
Retainer
Bracket
3/4" Thick Liner
Screw
Firebrick Side
Wall
Figure 12 - Inserting Firebox Into Cabinet
Mantel
INSTALLING GAS LINE
NOTICE: A qualified service person must connect heater to gas
supply. Follow all local codes.
Side
View
Chisel
IMPORTANT: See Connecting to Gas Supply in your log set owners manual for details
on gas hookup.
You may run the gas line from either side of
the firebox (see Figure 13). Decide which
side you want to run the gas line from.
Note: This is one option for installing shutoff
valve. Check local codes for shutoff valve
location requirements.
Remove
this Area
Product
Identification
Label
Figure 15 - Removing Side Panel
Knockout
Figure 14 - Location of Knockout for Gas
Line
10
103451
OWNER’S MANUAL
INSTALLATION
Continued
2.
Remove the screw and retainer bracket
at the top of the brick liner panel in the
back of the firebox. Do not let the panel
fall after the bracket is removed. Carefully remove the rear firebrick liner
panel from the firebox.
CAUTION: Do not let the firebrick liner panel fall after the
bracket is removed.
3.
Carefully lift and remove the bottom
firebrick floor from bottom of firebox.
Bracket
Screw
4.
Remove the four Phillips screws in firebox bottom.
5. Use the two finger holes in the firebox
bottom to carefully lift up and remove
the firebox bottom.
6. Locate duplex outlet mounted to support bracket in lower right hand side of
firebox. Remove screw holding duplex
outlet to support bracket in bottom of
firebox. Remove duplex outlet (see Figure 19).
7. Clamp electrical cable hard-wiring into
firebox through smallest hole using
strain relief fitting provided (see Figure 20).
8. Connect electrical cable to duplex outlet. Match wire colors to those on duplex outlet. Be sure to connect ground
wire.
9. Replace duplex outlet with screw.
10. You may now install GA3700 Blower
Accessory if desired. See installation
instruction sheet included with blower
kit.
11. Replace firebox bottom with four
Phillips screws.
12. Carefully replace firebrick panels in
reverse order (see Figures 15, 16, and
17, pages 10 and 11).
Rear Firebrick
Liner Panel
Figure 16 - Removing Rear Firebrick Liner
Panel
Electric
Cables
Duplex
Outlet
Support
Bracket
Screw
Figure 19 - Removing Duplex Outlet
Strain
Relief
Fitting
Electric
Cables
Small Hole
Figure 20 - Installing Strain Relief Fitting
into Electrical Access Hole
Screws
Finger
Holes
Firebox
Bottom
Screws
Figure 18 - Removing Firebox Bottom
Figure 17 - Removing Bottom Firebrick
Floor
103451
Continued
11
VANGUARD
UNVENTED (VENT-FREE) LOGMATE™ FIREBOX
Continued
TECHNICAL
SERVICE
INSTALLING FIREPLACE
SCREEN
You may have further questions about installation, operation, or troubleshooting.
1.
If so, contact DESA International’s Technical Service Department at
INSTALLATION
2.
3.
Insert each rod through all rings located
at top of screen.
Insert first rod into rear hole in left side
of firebox. Fasten rod to rear hole near
center of firebox using #10 x 3/8"
Phillips screw provided.
Insert other rod into front hole on right
side of firebox and fasten using remaining Phillips screw.
1-800-DESA LOG (1-800-337-2564).
REPLACEMENT
PARTS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Parts Under Warranty
Top View of Rod Layout
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Technical Service Department at
Screw
Rear Hole
Front Hole
Rod
Ring
Screen
1-800-DESA LOG (1-800-337-2564).
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
When calling DESA International, have
ready
• your name
• your address
• model number of your firebox
• how firebox was malfunctioning
• type of gas used (propane or natural gas)
• purchase date
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
Usually, we will ask you to return the defective part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Parts
Department at 1-800-972-7879 for referral
information.
Figure 21 - Installing Fireplace Screen (Models FB36CA and FB42C Shown)
When calling DESA International, have
ready
• model number of your firebox
• the replacement part number
Note: The firebox identification label (including model number, serial number, clearances, etc.) is located behind the left side
firebrick panel. See Figure 15, page 10.
12
103451
OWNER’S MANUAL
ACCESSORIES
BRASS TRIM ACCESSORY
(Not Shown)
Purchase these firebox accessories from your
local dealer. If they can not supply these
accessories, call DESA International’s Sales
Department at 1-800-432-2382 for information. You can also write to the address
listed on the back page of this manual.
GA6091 (36" Models)
GA6092 (42" Models)
Optional with built-in installation. Provides
a finished appearance covering rough and/
or unfinished mantel or wall opening edges.
BLOWER ACCESSORY GA3700
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
Use with Models FB36CA or FB42C only.
The variable blower allows you to select the
desired speed. The blower circulates heated
air from the fireplace into the room.
CABINET MANTEL
ACCESSORY WITH
FIREBOX PERIMETER
BRASS TRIM
GM103U Series - Unfinished
(36" Models)
Dimensions (WxHxD): 63" x 51" x 24 1/2"
GM105U Series - Unfinished
(42" Models)
MANUAL SHUTOFF VALVE GA5010
Manual shutoff valve with 1/8" NPT tap.
Dimensions (WxHxD): 69" x 51" x 24 1/2"
103451
13
BRASS HOOD ACCESSORY
(Not Shown)
GA6097 (36" Models)
GA6098 (42" Models)
Decorative polished brass hood enhances
the appearance of the firebox.
VANGUARD
UNVENTED (VENT-FREE) LOGMATE™ FIREBOX
ILLUSTRATED
PARTS
BREAKDOWN
19
19
20
16
19
FB36NCA AND FB42NC
17
1
7
9
2
17
4
17
18
3
18
13
17
2
6
18
5
11
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
15
18
17
18
12
10
8
14
18
14
103451
OWNER’S MANUAL
PARTS LIST
This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions
listed under Replacement Parts on page 12 of this manual.
FIREBOX
FB36NCA AND FB42NC
103451
KEY
NO.
PART NUMBER
FB36NCA
FB42NC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
103437-01
103608-01
103717-01
103718-01
103719-01
103720-01
103796-01
103440-01
103797-01
103297-02
103444-01CJ
103442-02CK
103445-01
103452-01
101348-01
103438-01
M11084-26
18
19
20
098304-01
098194-02
103436-01
DESCRIPTION
103437-02
103608-01
103717-02
103718-01
103719-01
103720-02
103796-02
103440-02
103797-02
103297-02
103444-02CJ
103442-04CK
103445-02
103452-02
101348-01
103438-02
M11084-26
098304-01
098194-02
103436-02
15
Firebox Top
Firebrick Retainer
Rear Firebrick
Left Side Firebrick
Right Side Firebrick
Bottom Firebrick
Outer Casing
Outer Casing Bottom
Firebox Wrapper
Screen Assembly
Hood
Front Assembly
Firebox Bottom
Screen Rod
Firebox Supports
Outer Casing Top
Hex Head Screw, #10-16
Hex Head Screw, #10-16
Phillips Pan Head Screw
Standoff Bracket
Deflector
QTY.
1
3
1
1
1
1
1
1
1
2
1
1
1
2
2
1
57
60
22
3
1
VANGUARD
UNVENTED (VENT-FREE) LOGMATE™ FIREBOX
ILLUSTRATED
PARTS
BREAKDOWN
16
FB36CA AND FB42C
17
1
7
9
2
17
17
4
18
19
3
18
13
17
2
6
18
5
11
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
15
18
17
18
12
21
10
8
14
20
18
16
103451
OWNER’S MANUAL
PARTS LIST
This list contains replaceable parts used in your firebox. When ordering parts, follow the
instructions listed under Replacement Parts on page 12 of this manual.
FIREBOX
FB36CA AND FB42C
103451
KEY
NO.
PART NUMBER
FB36CA
FB42C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
103437-03
103608-01
103717-01
103718-01
103719-01
103720-01
103796-01
103440-01
103797-01
103297-02
103444-01CJ
103442-01CK
103445-01
103452-01
101348-01
103438-01
M11084-26
18
19
20
21
098304-01
103771-01
103769-01
M12461-2
DESCRIPTION
103437-04
103608-01
103717-02
103718-01
103719-01
103720-02
103796-02
103440-02
103797-02
103297-02
103444-02CJ
103442-03CK
103445-02
103452-02
101348-01
103438-02
M11084-26
098304-01
103771-01
103769-01
M12461-2
17
Firebox Top
Firebrick Retainer
Rear Firebrick
Left Side Firebrick
Right Side Firebrick
Bottom Firebrick
Outer Casing
Outer Casing Bottom
Firebox Wrapper
Screen Assembly
Hood
Front Assembly
Firebox Bottom
Screen Rod
Firebox Supports
Outer Casing Top
Hex Head Screw, #10-16
Hex Head Screw, #10-16
Phillips Pan Head Screw
Strain Relief Fitting
Duplex Outlet
Outlet Mounting Screw
QTY.
1
3
1
1
1
1
1
1
1
2
1
1
1
2
2
1
50
53
22
1
1
1
VANGUARD
UNVENTED (VENT-FREE) LOGMATE™ FIREBOX
NOTES
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
18
103451
OWNER’S MANUAL
NOTES
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
103451
19
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our
standard written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
VENT-FREE FIREBOX
DESA International warrants this product to be free from defects in materials and components for three (3) years from the
date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with
all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore
this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center.
Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will
provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater
MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail
or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation.
As with all concrete liners, this liner may develop slight cracks when exposed to heat. This cracking is considered normal.
Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will
be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE
PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES
AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THREE (3) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY
LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE
LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or
consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply
to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
103451 01
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
NOT A UPC
103451-01
Rev. C