advertisement
▼
Scroll to page 2
of
34
DIRECT-VENT FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL NATURAL GAS MODELs (V)K36EN SERIES PROPANE/LP GAS MODELs (V)K36EP SERIES WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other ­flammable vapors and liquids in the ­vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. INSTALLER: Leave this manual with the appliance CONSUMER: Retain this manual for future reference. WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier. Installation and service must be performed by a qualified installer, service agency, or the gas supplier. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. For more information, visit www.desatech.com Table of Contents Safety Information.........................................................................2 Product Identification.....................................................................3 Local Codes..................................................................................3 Product Features...........................................................................3 Pre-Installation Preparation...........................................................4 Location of Termination Cap..........................................................6 Venting Installation Instructions.....................................................7 Fireplace Installation...................................................................14 Wiring Diagram............................................................................21 Operating Fireplace.....................................................................22 Safety Information WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm. IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosions, electrical shock, and carbon monoxide poisoning. DANGER: Carbon monoxide poisoning may lead to death! This fireplace must be installed by a qualified (certified or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system. It brings in fresh air for combustion through the outer pipe and combustion gases are exhausted through the inner pipe. If the glass door assembly and venting pipe are not properly seated, connected, and sealed, carbon monoxide leakage (spillage) can occur. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace. WARNING: Any change to this fireplace or its controls can be dangerous. Inspecting Burners......................................................................23 Cleaning and Maintenance..........................................................23 Troubleshooting...........................................................................25 Replacement Parts......................................................................27 Service Hints...............................................................................27 Technical Service........................................................................27 Specifications..............................................................................27 Illustrated Parts Breakdown and Parts List.................................28 Accessories.................................................................................32 Warranty Information.................................................... Back Cover 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity. 3. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any phone in your building • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions • if you cannot reach you gas supplier, call the fire department. 4. Never install the fireplace • in a recreational vehicle • in windy or drafty areas where curtains or other combustible (flammable) objects can make contact with the fireplace front • in high traffic areas 5. This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching. 6. Carefully supervise young children when they are in the room with fireplace. 7. Do not modify this fireplace under any circumstances. Any parts removed for servicing must be replaced prior to operating fireplace. 8. Turn fireplace off and let cool before servicing, installing, or repairing. Only a qualified service person should install, service, or repair this fireplace. Have fireplace inspected annually by a qualified service person. 9. You must keep control compartments, burners, and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace. 10. Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 23. 11. Keep the area around your fireplace clear of combustible materials, gasoline, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. www.desatech.com 111924-01D Safety information Continued 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate. 14. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. 15. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit. 16. Do not operate fireplace if any log is broken. 17. Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this fireplace. 18. Do not operate fireplace with glass door removed, cracked, or broken. 19. Provide adequate clearances around air openings. Product Identification Upper Louver Panel Flue Collar Log Set Nailing Flange Glass Door Assembly Lava Rock Local Codes Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Installation Code (Canada). *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 Product Features These are a few facts that can help you understand and enjoy your direct-vent fireplace: • The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exterior wall (horizontal). The vent pipe installation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications. • This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed. • The blower requires electricity if installed and if you plan to install the blower at a later date, do not forget to wire the outlet at the bottom of the fireplace when framing. • The electronic ignition creates spark to ignite the pilot light. It does not require any matches, batteries or any other sources of ignition to light the pilot. • Each time you turn on your fireplace, you may notice some amount of condensation on the inside of the fireplace glass. This is normal and will disappear after 10-20 minutes of operation. • Your direct-vent gas fireplace system (fireplace and venting) is a balanced and sealed gas operating unit. It requires approximately 1020 minutes of operating time before the flame pattern stabilizes. Control Valve Lower Louver Panel Burner Assembly Glowing Embers Switch Bracket for Optional Remote and Blower Figure 1 - Tudor Direct-Vent Fireplace with Electronic Ignition 111924-01D www.desatech.com Pre-Installation Preparation Location and space requirements Flush with a wall Determine the safest and most efficient location for your DESA direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common locations. Be aware of all restrictions and precautions before deciding the exact location for your fireplace and termination cap. When deciding the location of your fireplace, follow these rules: • Do not connect this fireplace venting to a chimney flue serving a separate solid-fuel burning fireplace or appliance. • Due to high temperatures, do not locate this fireplace in high traffic areas, windy or drafty areas, or near furniture or draperies. • Proper clearances must be maintained. • If your fireplace is to be installed directly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3. • Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the back, sides, or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing material. See framing details on page 5. • If you plan on installing a television or entertainment center recessed above your fireplace, it is recommended that you maintain a minimum 18" above top of louver opening. • When locating termination cap, it is important to observe the minimum clearances shown in Figure 7, page 6. • If recessing into a wall, you can avoid extra framing by positioning your fireplace against an already existing framing member. • Do not recess termination cap into a wall or siding. • You may paint the termination cap with 450º F (232º C) heatresistant paint to coordinate with the exterior finish. • There must not be any obstruction such as bushes, garden sheds, fences, decks, or utility buildings within 24" from the front of the termination cap. • Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area. Corner installation Through exterior wall enclosed in a chase Figure 2 - Common Fireplace Locations 29" RW 21D1/8" 41" FW Figure 3 - Fireplace Bottom Dimensions Clearances Minimum clearances to combustibles for the fireplace are as follows: Back, and sides 0"/mm Perpendicular walls 6" (15.2 cm) Floor 0"/mm Ceiling to louver opening 42" (106.7 cm) Front 36" (91.4 cm) Top 0"/mm Vent (See venting instructions for specific venting clearances.) Combustible material with a maximum thickness of 5/8" may be flush with the top front of fireplace . NOTICE: This fireplace is intended for use as supplemental heat. Use this fireplace along with your primary heating system. Do not install this fireplace as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using fireplace. This will help circulate the heat throughout the house. www.desatech.com 111924-01D Pre-Installation Preparation 1 2 Continued 3 A framing and finishing 4 Figure 4 shows typical framing of this fireplace. Figure 5 shows framing for corner installation. All minimum clearances must be met. For available accessories for this fireplace, see Accessories on page 32. If you are using a separate combustible mantel piece, refer to Figure 6 for proper installation height. You can install noncombustible mantels at any height above the fireplace. Note: Noncombustible mantels may discolor! B Wall 5 C 6 D E 7 F G Top of Louver Opening Ref. Mantel Ref. Mantel from Top Depth of Louver Opening 1 14" A 16" 2 12" B 14" 3 10" C 12" 4 8" D 10" 5 6" E 8" 6 4" F 6" 7 2" G 4" Figure 6 - Clearances for Combustible Mantels 36 1/8" 41 1/4" 23 1/2" Figure 4 - Framing Clearances for Installation Against an Exterior Wall D 3/8" 10 15" B 49 C 5/8" 35A 3/4" E 13 3/4" F 41" 41 1/4" G Nailing Nailing Tabs Tabs 1 68 H /2" Figure 5 - Framing Clearances for Corner Installation 111924-01D www.desatech.com Location of Termination Cap N N D H V L E B C Fixed Closed F B Openable Fixed Closed V Openable V I V G B V B B J X V G G M A V K X V A V TERMINATION CAP G GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) clearance to service regulator vent outlet [*72" (182.9 cm) minimum] clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12" (30.5 cm) minimum] clearance to a mechanical air supply inlet [*72" (182.9 cm) minimum] † clearance above paved side-walk or a paved driveway located on public property [*84" (213.3 cm) minimum] clearance under veranda, porch, deck [*12" (30.5 cm) minimum ‡] clearance above a roof shall extend a minimum of 24" (61 cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18" (45.7 cm) X AIR SUPPLY INLET A = clearance above grade, veranda, porch, deck, or balcony I = [*12" (30.5 cm) minimum] B = clearance to window or door that may be opened J = [12" (30.5 cm) minimum] C = clearance to permanently closed window [minimum 12" (30.5 cm) recommended to prevent condensation on window] K = D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24" (61cm) from the L = center-line of the terminal [18" (45.7 cm) minimum] E = clearance to unventilated soffit [12" (30.5 cm) minimum] M= F = clearance to outside corner (see below) N = G = clearance to inside corner (see below) H = *not to be installed above a meter/regulator assembly within 36" (91.4 cm) horizontally from the center-line of the regulator † vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* ‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A. Note: Local codes or regulations may require different clearances Termination Clearances for Buildings with Combustible and Noncombustible Exteriors Inside Corner Outside Corner Recessed Location D C A C A = 6" (15.2 cm) E V V V B = 6" (15.2 cm) B Balcony with No Side Wall Balcony with Perpendicular Side Wall H G V V J G = 12" (30.5 cm) minimum clearance Combustible & Noncombustible H = 24" (61 cm) J = 20" (50.8 cm) C = Maximum depth of 48" (121.9 cm) for recessed location D = Minimum width for back wall of recessed location Combustible - 38" (96.5 cm) Noncombustible - 24" (61cm) E = Clearance from corner in recessed locationCombustible - 6" (15.2 cm) Noncombustible - 2" (5.1 cm) Figure 7 - Minimum Clearances for Termination Cap www.desatech.com 111924-01D Venting Installation Instructions NOTICE: Read these instructions completely before attempting installation. These models are tested and approved for use with DESA (directvent) pipe components and terminations as well as Simpson-Duravent direct-vent pipe components and terminations. The venting system must terminate on the outside of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance. A direct-vent appliance must have its own venting system. DO NOT common vent this appliance. These models are approved to be vented either horizontally through an outside wall or vertically through a roof or chase enclosure using the following guidelines: • When venting system terminates horizontally on an outside wall, you must install a standoff if the termination cap is to be installed directly on a combustible finish such as vinyl, wood, stucco, etc. • Never run the vent downward as this may cause excessive temperatures which could cause a fire. • Vent pipe air space clearances to combustibles are 1" on all sides except on the horizontal sections, which requires 2" clearance from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required. • Snorkel terminations are required when minimum clearance to grade cannot be met (see Figure 16 on page 11). • Have fireplace and selected vent components on hand to help determine the exact measurements when elbowing or offsetting. Always use wall firestops when penetrating walls and firestops when penetrating ceilings or attic spaces. • If using a venting configuration of only horizontal venting with no vertical run, a 1/4" rise for every 12" of run toward the termination is required. WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. NOTICE: Failure to follow these instructions will void the warranty. IMPORTANT: Do not seal vent cap to pipe. Cap must be removable for service. 111924-01D Installation Precautions • Wear gloves and safety glasses for protection • Use extreme caution when using ladders or when on roof tops • Be aware of electrical wiring locations in walls and ceilings The following actions will void the warranty on your venting system: • Installation of any damaged venting component • Unauthorized modification of the venting system (Do not cut or alter vent components) • Installation of any component part not manufactured or approved by DESA • Installation other than as instructed by these instructions WARNING: This gas fireplace and vent assembly must be vented directly to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each directvent gas appliance must use a separate vent system. Do not use common vent systems. WARNING: Vent pipe air space clearances to combustibles are 1" on all sides except on the horizontal sections, which require 2" clearances from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required. INSTALLATION PLANNING There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination Horizontal Termination Installation IMPORTANT: Horizontal square terminations require only inner portion of wall firestop. Horizontal installations using round termination require exterior portion of wall firestop (see Figure 14, page 10). 1. Set the fireplace in its desired location and determine the route your horizontal venting will take. Do not secure the fireplace until all venting has been installed. Some installations require sliding the fireplace in and out of position to make final venting connections. Figures 14 through 18 on pages 10 and 11 show different configurations for venting with horizontal termination that will help you decide which application best suits your installation. Check to see if wall studs or roof rafters are in the path of your desired venting route. If they are, you may want to adjust the location of the fireplace. www.desatech.com Venting Installation instructions Female Locking Lugs Continued 2. Direct vent pipe sections and components are designed with special twist-lock connections. Twist-Lock Procedure: The female ends of the pipes have locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes. Push pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked (see Figure 8). Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose. 3. Use a 45° elbow to connect venting system to fireplace flue collar. The elbow is designed to be twist-locked onto the flue collar as described in step 2. IMPORTANT: Do not attempt to alter the configuration of the elbow by cutting, twisting, bending, etc. 4. Assemble the desired combination of pipe and elbows to the fireplace. If there are long portions of venting run, pre-assembled pipe sections may be installed as subassemblies for convenience. 5. Carefully determine the location where the vent pipe assembly will penetrate the outside wall. The center of the hole should line up with the center-line of the horizontal vent pipe. Mark the wall for a 10 3/4" x 10 3/4" square hole. Cut and frame the square hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncombustible material, such as masonry block or concrete, a 8 1/2" hole with zero clearance is acceptable (see Figure 9). Male Slots Figure 8 - Vent Pipe Connections Vent Opening Combustible Wall 10 3/4" (27.3 cm) 10 3/4" Inside Framing (27.3 cm) 10 3/4" (27.3 cm) Vent Opening Noncombustible Wall 8 1/2" (21.6 cm) (Framing Detail) Center of Hole WARNING: Do not recess vent termination into any wall. This will cause a fire hazard. 6. Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 8 1/2" round hole and attach to the exterior wall with four wood screws provided. Before attaching the vent cap to exterior wall, run a bead of non-hardening mastic (pliable sealant) around the outside edges to make a seal between it and the outside wall. Note: The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings. Combustible Exterior Wall: For vinyl siding, stucco, or wood exteriors, a siding standoff must be installed between the vent cap and exterior wall. The siding standoff prevents excessive heat from damaging the siding materials. Siding material must be cut to accommodate standoff. Bolt the vent cap to the standoff. Apply non-hardening mastic around outside edge of standoff. Position the standoff/cap assembly in the center of the 10 3/4" square hole and attach to exterior wall with wood screws provided (see Figure 11, page 9). The siding standoff must sit flush against the exterior fascia material. Figure 9 - Vent Opening Requirements Apply Mastic to All Four Sides Vent Cap Wood Screw Figure 10 - Installing Horizontal Vent Cap (Noncombustible Exterior) www.desatech.com 111924-01D Venting Installation instructions Minimum Pipe Overlap 11/4" Continued 7. Combustible Exterior Wall Only: Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap (see Figure 12). 8. Carefully move fireplace, with vent assembly attached, toward wall and insert vent pipe into horizontal termination. The pipe overlap should be a minimum of 11/4". 9. Combustible Exterior Wall Only: Slide wall firestop against interior wall surface and attach with screws provided. See Figure 13 for horizontal termination details. 10. Place fireplace into position and shim with noncombustible material if needed. Nail or screw side flanges to framing to secure unit in place. IMPORTANT: Make sure fireplace is level before securing. If fireplace is not level it will not work properly. Screws Direct Vent Pipe Wall Firestop Maintain 1" Minimum Air Space Around Outer Pipe When Penetrating a Wall Cut Siding Away to Fit Standoff 10 3/4" x 10 3/4" Framed Opening Standoff Wood Screw High Wind Termination Apply Mastic to Outside Edge of Standoff Exterior Wall with Vinyl Siding Vent Cap Screws Siding Standoff Figure 13 - Typical Horizontal Termination Cap Mounting with Additional Siding Standoff Installed Apply Mastic to All Four Sides Figure 11 - Installing Siding Standoff (Combustible Exterior) Interior Wall Surface Wall Firestop Vent Cap (Horizontal Termination) Horizontal Vent Pipe Screw Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe 111924-01D www.desatech.com Venting Installation instructions Continued Horizontal Termination Configurations Figures 14 through 18 show different configurations and alternatives for venting with horizontal termination. Each figure includes a chart with critical minimum and maximum dimensions which MUST be met. IMPORTANT: If using a venting configuration of only horizontal venting with no vertical run, a 1/4" rise for every 12" of run toward the termination is required. WARNING: Never run vent downward as this may cause excessive temperatures which could cause a fire. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life. CORNER AND ALTERNATE INSTALLATION Recommended Applications: • Corner ground floor installation • Ground floor installation where pipe vents horizontally through wall (over 12" horizontal pipe) • Basement installation where one foot clearance from ground to termination is possible Not to Exceed (H) Limits Wall Firestop As Required for (V) See Chart for Pipe Section Required Square Termination 45° Elbow GROUND FLOOR INSTALLATION Recommended Applications: • Installation using cabinet surrounds • Through the wall using round or square termination (up to 12" horizontal pipe) • NOT FOR CORNER INSTALLATION Adjustable 45° Elbow Pipe 12" Max. Horizontal High Wind Square Termination Required Vertical (V) Vertical Pipe *431/2" min. None 541/2" min. 1 ft. 661/2" min. 2 ft. 781/2" min. 3 ft. 901/2" min. 4 ft. *Ground Floor Corner Venting Not to Exceed (H) Limits Wall Firestop 90° Elbow 90° Elbow Horizontal (H) 30" max. 48" max. 60" max. 84" max. 20' max. Square Termination Square Termination Vertical (V) Horizontal (H) 32 3/4" min. 17" max. 45° Elbow Wall Firestop Wall Firestop Exterior Portion of Wall Firestop (Round Termination Only) Horizontal Round Termination 12" Minimum 45° Elbow Figure 15 - Horizontal Termination Configuration for Corner Installation Using One 90° Elbow Figure 14 - Horizontal Termination Configuration for Square and Round Terminations 10 www.desatech.com 111924-01D Venting Installation instructions Continued SNORKEL TERMINATION INSTALLATION Recommended Applications: • Installations requiring a vertical rise on building exterior • Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If installing snorkel termination below grade, you must provide proper drainage to prevent water from entering snorkel termination (see Figure 16). Do not back fill around snorkel termination. Snorkel Termination Snorkel Termination Snorkel Termination 90° Elbow 12" Minimum Wall Firestop 12" Minimum 45° Elbow 12" Minimum Adequate Drainage Figure 16 - Snorkel Termination Configurations for Below Ground Installation HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows. Venting with Two 90° Elbows Vertical (V) Horizontal Horizontal (H1) + 5' min. 6' min. 7' min. 8' min. 20' max. (H1) 2' max. 4' max. 6' max. 8' max. 8' max. Horizontal (H2) 6' max. 12' max. 18' max. 20' max. 20' max. Venting with Two 90° Elbows Vertical (V) Horizontal (H1) 45° Elbow 5' min. 6' min. 7' min. 8' min. 20' max. Horizontal (H2) 45° Elbow 6' max. 12' max. 18' max. 20' max. 20' max. Figure 18 - Horizontal Termination Configuration for Venting Using Two 90° Elbows with Termination at 90° with Fireplace Figure 17 - Horizontal Termination Configuration for Venting Using Two 90° Elbows 111924-01D www.desatech.com 11 Venting Installation instructions Continued installation for vertical termination Note: Vertical restrictor must be installed in all vertical installations. 1. Determine the route your vertical venting will take. If ceiling joists, roof rafters, or other framing will obstruct the venting system, consider an offset (see Figure 19) to avoid cutting load bearing members. Note: Pay special attention to these installation instructions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, etc. Do not pack air spaces with insulation. Also note maximum vertical rise of the venting system and any maximum horizontal offset limitations. 2. Set the fireplace in desired location. Drop a plumb line down from the ceiling to the position of the fireplace exit flue. Mark the center point where the vent will penetrate the ceiling. Drill a small locating hole at this point. Drop a plumb line from the inside of the roof to the locating hole in the ceiling. Mark the center point where the vent will penetrate the roof. Drill a small locating hole at this point. Roof Flashing Wall Strap 45° Elbow Ceiling Firestop Figure 19 - Offset with Wall Strap and 45° Elbows 2. Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop. Be sure all pipe and elbow connections are fully twist-locked (see Figure 8, page 8). 3. Cut a hole in the roof using the locating hole as a center point. (Cover any exposed open vent pipes before cutting hole in roof.) The 10 3/4" x 10 3/4" hole must be measured on the horizontal; actual length may be larger depending on the pitch of the roof. There must be a 1" clearance from the vent pipe to combustible materials. Frame the opening as shown in Figure 9, page 8. 4. Connect a section of pipe and extend up through the hole. Note: If an offset is needed to avoid obstructions, you must support the vent pipe every 3 feet. Use wall straps for this purpose (see Figure 19). Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less restriction to the flow of the flue gases and intake air. 5. Place the flashing over the pipe section(s) extending through the roof. Secure the base of the flashing to the roof and framing with roofing nails. Be sure roofing material overlaps the top edge of the flashing as shown in Figure 19. There must be a 1" clearance from the vent pipe to combustible materials. 6. Continue to add pipe sections until the height of the vent cap meets the minimum building code requirements described in Figure 7 on page 6. Note: You must increase vent height for steep roof pitches. Nearby trees, adjoining roof lines, steep pitched roofs, and other similar factors may cause poor draft or down-drafting in high winds. Increasing the vent height may solve this problem. 7. Twist-lock the vent cap onto the last section of vent pipe. Note: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclosure with standard construction material. Make sure and meet the minimum allowable clearances to combustibles. Do not fill any of the required air spaces with insulation. If area above is an attic space or insulated area, install firestop above framed hole. Flat Ceiling Installation 1. Cut a 10 3/4" square hole in the ceiling using the locating hole as a center point. The opening should be framed to 10 3/4"x 10 3/4" (27.3 cm x 27.3 cm) inside dimensions, as shown in Figure 9 on page 8 using framing lumber the same size as the ceiling joists. If the area above the ceiling is an insulated ceiling or an attic space, nail firestop from the top side. This prevents loose insulation from falling into the required clearance space. If the area above the ceiling is a living space, install firestop below the framed hole. The firestop should be installed with no less than three nails per side (see Figure 20). 12 If area above is a living space, install firestop below framed hole. www.desatech.com Figure 20 - Installing Firestop 111924-01D Venting Installation instructions Continued Venting with Two 90° Elbows Vertical (V1) Horizontal (H) 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. Vertical Termination Configurations Figures 21 through 24 show four different configurations for vertical termination. Venting with Two 90° Elbows Vertical (V) Horizontal (H1) + Horizontal (H2) 5' min. 2' max. 6' min. 4' max. 7' min. 6' max. 8' min. 8' max. 20' max. 8' max. Note: Install restrictor into inner collar of fireplace as shown. 45° Elbow 45° Elbow Note: Vertical (V1) + Vertical (V2) = 40' max. Figure 23 - Vertical Venting Configuration Using Two 90° Elbows (Vertical Round High Wind Termination Shown) Note: Install restrictor into inner collar of fireplace as shown. Figure 21 - Vertical Venting Configuration Using Two 90° Elbows with Two Horizontal Runs (Vertical Round High Wind Termination Shown) Venting with One 90° Elbow Vertical (V) Horizontal (H) 5' min. 2' max. 6' min. 4' max. 7' min. 6' max. 8' min. 8' max. 20' max. 8' max. 45° Elbow Vertical Venting V = 40' max. Note: Install restrictor into inner collar of fireplace as shown. 45° Elbow Note: Install restrictor into inner collar of fireplace as shown. Figure 22 - Vertical Venting Configuration Using One 90° Elbow (Vertical Round High Wind Termination Shown) 111924-01D Figure 24 - Vertical Venting Configuration With No Horizontal Run (Vertical Round High Wind Termination Shown) www.desatech.com 13 Venting Installation instructions Continued High Altitude Installation Your DESA direct-vent fireplace has been CSA tested and approved for elevations from 0-2000 feet (USA) and elevations from 0-4500 feet (Canada). When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification. When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities. Consult your local gas company to help determine the proper orifice for your location. For assistance with any high altitude installation contact DESA Customer Service Department at 1-866-672-6040. Parts lists for venting kits and components DESA Pipe & Vent Kits 6" Section Double Wall Pipe - Galvanized P58-12 12" Section Double Wall Pipe - Galvanized P58-24 24" Section Double Wall Pipe - Galvanized P58-36 36" Section Double Wall Pipe - Galvanized P58-48 48" Section Double Wall Pipe - Galvanized FPA58-6 6" Duravent Collar to FMI Pipe Adaptor (6" Collar/Pipe Section) DPA58-6 6" FMI Collar to Pipe Duravent Adaptor (6" Collar/Pipe Section 45° Elbow, Galvanized E58-90 90° Elbow, Galvanized DSE58-45 45° Starter Elbow, Galvanized (FMI Collar to Duravent Pipe) Ground Floor Vent Kit - Galvanized VKB-58 Basement Vent Kit - Galvanized VKS-58 Snorkel Kit - Galvanized VKR-58 Roof Vent Kit - Galvanized VKC-58 Corner Vent Kit - Galvanized HTK Horizontal Round Termination Kit HT-58 Horizontal Round Termination Kit, Galvanized Storm Collar - Galvanized WF-58 Wall Firestop - Galvanized RF-58-6 Roof Flashing - 0 to 6/12 Pitch - Galvanized RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch - Galvanized VR-58 Vertical Restrictor - Galvanized S-58 Vinyl Siding Standoff - Galvanized WS-58 Wall Strap CS-58 Cathedral Ceiling Support FP-58 Firestop Plate SF-58 Stucco Flashing - For use with HTS-5 Fireplace Installation CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type. WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury. Model BK Installation Follow all instructions provided in the blower accessory kit. FSE58-45 45° Starter Elbow, Galvanized (Duravent Collar to FMI Pipe) VKG-58 SC-58 NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas supply and disconnect heater from gas supply. Contact a qualified service person to do this. PA58-712 Adjustable 7"-12" Section Coaxial Pipe - Galvanized E58-45 ST-58-36 36" Snorkel Termination, Galvanized Installing optional blower accessories Number Description P58-6 Number Description 1. Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 25). Blower Location Lower Firebox Cavity Side View Spade Terminals Exhaust Port HTKS-58 Horizontal Square Termination Kit HTS-58 Horizontal Square Termination Kit, Galvanized VT-58 Vertical Round Termination, Galvanized Magnetic Strips Green Ground Wire Screw ST-58-14 14" Snorkel Termination, Galvanized Figure 25 - Blower Model BK 14 www.desatech.com 111924-01D Fireplace Installation Continued kc kc B W al ih ffO kc B et al B 1 01 1/ .V 51 C.A . B al kc h W i et er G ne Wiring Diagram Decal 12" in Front of Blower Figure 27 - Location of Wiring Diagram Decal (Model May Vary From Illustration) Model BKT Installation Note: When installing the BKT thermostatically-controlled blower, you must first secure the thermal switch bracket to the blower if it has not already been factory installed. 1. Place the green ground wire with ring terminal between the bottom hole on the thermal switch bracket and the top ear hole on the blower assembly. Insert the Phillips screw into all three pieces and tighten securely (see Figure 28). 2. Connect wire harness and power cord terminals. Connect the blue jumper wire to the blower motor terminal and the right side terminal of the thermal switch. Connect the black wire to the left side of the thermal switch and the white wire to the other remaining blower motor terminal. Note: The power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connections. DO NOT trim excessive length away. Just enable enough to make all connections securely. White Wire Blue Wire Power Cord Thermal Switch Bracket Black Wire Phillips Screw Thermal Switch Route BKT Blower Through This Area Ring Terminal on Green Wire Air Flow Direction Magnets Thermodisc Side View Firebox Bottom Locknut Control Knob Control Shaft Magnetic Strips Air Flow Direction Speed Control Blower Plug-In al Switch Bracket nO 9. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by turning knob fully counterclockwise before continuing. 10. Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12" in front of the blower (see Figure 27). B ol w M re oto r CAUTION: Never touch the blower wheel while in operation. V F ira na ba S e l ti w hc 2. Attach green ground wire from power cord to blower housing using screw provided (see Figure 25, page 14). Tighten screws securely. 3. Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 25, page 14). 4. Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retaining the green ground wire is tight. 5. Mount speed control box to switch bracket by placing the plastic control shaft forward through the opening in the switch bracket (see Figure 26). 6. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft. 7. Turn on power to duplex outlet if previously turned off per the warning in column 2, page 14. 8. Plug in blower power cord. a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox. b.If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox owner’s manual for instructions on wiring the duplex outlet. Duplex Outlet (Located underneath firebox floor against lower right outside wall) Figure 28 - Blower Model BKT Blower Location Figure 26 - Attaching Speed Control to Firebox 111924-01D www.desatech.com 15 Fireplace Installation Continued 3. Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward and the thermodisc positioned up near the fireplace bottom. The thermodisc must be oriented near the fireplace bottom as shown in Figure 28, page 15, in order to sense temperature and properly operate. The blower will be held in position against the back wall by the magnets incorporated onto the blower housing (see Figure 28, page 15). 4. Be certain that all wire terminals are securely attached to terminals on blower motor and thermal switch, and that the screw for the thermodisc bracket and green ground wire is tight. 5. Mount the speed control box against the mounting plate provided in the lower fireplace cavity by placing the plastic control shaft forward through the round hole (see Figure 26, page 15). 6. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against mounting plate. Place control knob provided on shaft (see Figure 26, page 15). 7. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Also double check all wire leads and make sure wire routing is not pinched or in a precarious position. Correct accordingly. 8. Turn on power to duplex outlet if previously turned off per the warning in column 2, page 14. 9. Plug in blower power cord to duplex outlet. 10. The blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up. The blower speed can be adjusted by rotating the control knob. To turn off, turn knob fully counterclockwise until it clicks off. If the blower is ON and has been running with the fireplace operating, the blower will continue to run for a short time after the fireplace has been turned off. As the thermal switch cools down, the blower shuts down automatically. 11. Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12" in front of the blower (see Figure 27, page 15). Blower Wiring Diagram CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Variable Fan Switch Off 1 2 Installing Gas Piping to Fireplace Location WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes. CAUTION: For propane/LP units, never connect fireplace directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply. Installation Items Needed Before installing fireplace, make sure you have the items listed below. • • • • • • • • • external regulator (supplied by installer) piping (check local codes) sealant (resistant to propane/LP gas) equipment shutoff valve * test gauge connection * sediment trap tee joint pipe wrench approved flexible gas line with gas connector (if allowed by local codes) * A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your retailer. For propane/LP connection only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 30. Pointing the vent down protects it from freezing rain or sleet. CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur. External Regulator Fan Switch (N.O.) Propane/LP Supply Tank Vent Pointing Down Black On 110/115 V.A.C. Blue Black White Green Figure 30 - External Regulator with Vent Pointing Down (Propane/LP Only) Blower Motor Figure 29 - Blower Wiring Diagram for Thermostat-Controlled Models 16 www.desatech.com 111924-01D Fireplace Installation Continued Installation Items Needed Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 31). IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the appliance. Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves. WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas. We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 31. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap/drip leg is not installed or is installed wrong, fireplace may not run properly. CSA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap* Natural - From Gas Meter (5.5" W.C. to 10.5" W.C. Pressure) Propane/LP From External Regulator (11" W.C. to 14" W.C. Pressure) Approved Flexible Gas Line 3" Minimum CONNECTING FIREPLACE TO GAS SUPPLY • 5/16" hex socket wrench or nut-driver • sealant (resistant to propane/LP gas, not provided) 1. Open lower louver door panel by gently pulling forward. 2. Route flexible gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one of the access holes on side of fireplace. 3. Attach flexible gas line from gas supply to control valve (see Figure 32). 4. Check all gas connections for leaks. See Checking Gas Connections. Equipment Shutoff Valve 1/2" NPT Incoming Gas Line Flexible Gas Line Do NOT Kink Red Surface Indicates For Propane/LP Use Only Inlet Pressure Tap Outlet Pressure Tap Note: Wire Connections Not Shown for Clarity Figure 32 - Connecting Flexible Gas Line to Electronic Valve CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. Pressure Testing Gas Supply Piping System Cap Pipe Nipple Tee Joint Sediment Trap/Drip Leg Figure 31 - Gas Connection * The CSA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your retailer. 111924-01D Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its individual equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. 5. Reconnect fireplace and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. www.desatech.com 17 Fireplace Installation Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 33). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air. 3. Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 34 or 35). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. Equipment Shutoff Valve Open 1. Open equipment shutoff valve (see Figure 33). 2. Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to gas valve (see Figure 34 or 35). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. 5. Light fireplace (see Operating Fireplace, page 22). Check all other internal joints for leaks. 6. Turn off fireplace (see To Turn Off Gas to Appliance, page 22). Removing/Replacing Glass Door CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part information see Replacement Parts, page 27. Closed CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass. Figure 33 - Equipment Shutoff Valve Propane/LP Supply Tank Pressure Testing Fireplace Gas Connections Equipment Shutoff Valve WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before removing glass door or louvers. Removing Louver Panels Remove the top and bottom louver panels by simultaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 36). Repeat for bottom spring latches and pull the louvers outward. To install or replace items removed, simply reverse the procedures above. Gas Valve Figure 34 - Checking Gas Joints for Propane/LP Gas Fireplace Equipment Shutoff Valve Gas Meter Spring Latch Louver Panel Figure 36 - Removing Louver Panel Gas Valve Figure 35 - Checking Gas Joints for Natural Gas Fireplace 18 www.desatech.com 111924-01D Fireplace Installation Continued Removing Glass Door If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame. 1. Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/rod assembly from the firebox. Set assembly aside. 2. Lift up on latches to unlock. There are two on top of firebox and two below firebox that hold glass door in place (see Figure 37). 3. While holding glass door to prevent it from falling and causing injury, remove the five screws from the hinge located on the left side of door frame assembly (see Figure 37). 4. Remount the new frame at the hinge with five new screws before closing door. This will ensure seating of the gasket. 5. Close glass door frame. Lock latches by placing the bar under the tab on door and pushing down and back on latch (see Figure 37). 6. Replace screen/rod assembly by reversing step 1. 7. Replace louvers by reversing procedure under Removing Louver Panels, page 18. Unlock Lock Latch Screw Hinge Glass Frame Assembly Installing Optional Brick liner Models BL36DA(SA), BL36DHA(SA) WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before installing brick liner. You may purchase brick liner from your local retailer or see Accessories, page 32. CAUTION: Always handle brick panels with two hands. Do not force brick panels into place. Excessive force will break brick panels. 1. Remove top and bottom louvers to allow access to door latches. 2. Unlock door latches and open glass door. See steps 1 and 2 of Removing Glass Door, column 1. 3. If installing brick liner in new fireplace, go to step 4. If installing brick liner in an existing fireplace, carefully remove logs, lava rock, and ember material. 4. Remove three screws from deflector shield on the inside top of firebox. Set shield and screws aside. 5. Install rear brick panel first. Rest bottom edge of panel on back edge of grate (see Figure 38). 6. Install left side brick panel by sliding it between burner assembly and side of firebox (see Figure 38). 7. Install the right brick panel using the same method described in step 6 for the left brick panel. 8. Replace deflector shield using screws removed in step 4. 9. Install logs, lava rock, and glowing embers (see Installing Logs, Lava Rock and Glowing Embers, page 20). 10. Close glass door, lock latches on top and bottom of door and replace screen (see steps 5 and 6 of Removing Glass Door, column 1). 11. Close top and bottom louvers. Left Side Brick Panel Figure 37 - Removing/Replacing Glass Door Cleaning Glass Door See Cleaning and Maintenance on page 23. Rear Brick Panel Figure 38 - Installing Rear Brick Panel 111924-01D www.desatech.com 19 Fireplace Installation Continued Installing logs, lava rock and glowing embers Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with fireplace. Open louvers, remove screen, unlock door latches, and open glass door. See steps 1 and 2 of Removing/Replacing Glass Door, page 19. Install logs according to instructions for fireplace model numbers. 1. Place log #1 (left base log) onto pin on left side of burner as shown in Figure 39. 2. Place log #2 (right base log) onto pin on right side of burner as shown in Figure 39. 3. Place logs #3 (left front log) and log #4 (right front log) onto pins as shown in Figure 40. 4. Place log #5 (right rear log) onto pins on right rear of burner (see Figure 41). Rest log #6 (middle crossover log) on top of log number 2 as shown in Figure 41. 5. Place back end of log #7 (left rear log) onto pin on left rear burner and rest front onto log #1 as shown in Figure 42. 6. Rest log #8 (left crossover log) onto log #3 and rest log #9 (right crossover log) onto logs #4 and #5 as shown in Figure 43. 2 1 3 4 7. Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the exposed front section of the burner (see Figure 44). This will create the glowing ember appearance as the flame touches the ember material. Do not block air slots by using too much ember material in one area. It is not necessary to use all of the ember material provided. NOTICE: Do not put lava rock on burner or under burner. Placing lava rock on burner will cause performance problems. 8. Close glass door, lock door latches, replace screen, and close louvers (see Removing Glass Door, steps 5 through 7, page 19). WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken. Ember Material Figure 44 - Placing Ember Material on Burner WALL SWITCH INSTALLATION The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies the electricity to the fireplace. See Wiring Diagram on page 21. optional Remote control INSTALLATION (model WRC) Figure 39 - Installing Logs No. 1 and No. 2 5 Figure 40 - Installing Logs No. 3 and No. 4 1. Open lower louver panel of firebox. 2. The WRC model receiver does not require a battery. The receiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 45). 7 6 Figure 41 - Installing Logs No. 5 and No. 6 Note: If using optional wireless hand-held remote control, the wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace operation. Fireplace Receptacle Figure 42 - Installing Log No. 7 Remote Control Receiver 9 8 Extension Cord Figure 43 - Installing Logs No. 8 and No. 9 20 Ignition Module Plug Figure 45 - Installing the WRC Remote Receiver www.desatech.com 111924-01D Fireplace Installation Battery Cover 12 Volt Battery Continued 3. Activate the remote handset battery by removing the insulating tab on the back of the handset (see Figure 46). The battery is included pre-installed. 4. Once the battery is activated the unit is ready to use. 5. Close lower louver panel. Pull to Remove Insulation Tab Back of Handset Figure 46 - Installing Battery into Back of Handset Wiring Diagram Pilot Burner Pilot Gas Line OFF WALL SWITCH (SUPPLIED) ON INCOMING MAIN GAS SUPPLY BLACK MV WHITE TR GND PV BLACK WHITE GREEN PV/MV Robertshaw MODEL SP745 IGNITION CONTROL TH EV1 GREEN INCOMING 120V AC (FUSE BOX OR BREAKER) IGN ELECTRICAL RATING: 120v, 60Hz, 0.7A EV2 24V AC STEP DOWN TRANSFORMER 120V AC OPTIONAL REMOTE CONTROL GAS LINE TO BURNER 111924-01D www.desatech.com 21 Operating Fireplace for your safety read before lighting WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. C. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Lighting instructions NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. STOP! Read the safety information, above. Turn off all electric power to the appliance. Turn wall switch to the OFF position. Open lower louver panel. Turn equipment shutoff valve clockwise to the OFF position (see Figure 47). Do not force. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step. Turn equipment shutoff valve counterclockwise to the ON position. Do not force. Close lower louver panel. Turn on all electric power to the appliance. Turn the wall switch to the ON position. Equipment Shutoff Valve Adjustment Screw Figure 47 - Turning Equipment Shutoff Valve to the OFF Position 22 11. Visually locate the pilot. The ignitor should begin to spark and the main burner should ignite once flame appears at pilot. • If lighting the appliance for the first time each season, it may take several attempts before the supply gas can reach the pilot and main burners. • If the appliance will not stay lit after several attempts, follow the instructions To Turn Off Gas To Appliance, and call your service technician or gas supplier. Sensing Rod Pilot Burner Ignitor Figure 48 - Pilot TO TURN OFF GAS TO APPLIANCE 1. Turn off the wall switch. 2. Turn off all electric power to the appliance if service is to be performed. 3. Open lower louver panel. 4. Turn equipment shutoff valve clockwise to OFF. Do not force. 5. Close lower louver panel. OPTIONAL REMOTE OPERATION Note: The WRC receiver and hand-held remote control kit must be purchased separately (see Accessories, page 32). Follow installation instructions on page 20. 1. Turn equipment shutoff valve to ON position. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation. 2. Press the ON/OFF button to turn the burner on and off. operating optional blower accessory Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel. The BK manual blower and the BKT thermostatically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate. Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases. The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air. www.desatech.com 111924-01D Inspecting Burners Cleaning and Maintenance Check pilot flame pattern and burner flame patterns often. pilot assembly The pilot assembly is factory preset for the proper flame. Alterations may have occurred during shipping and handling. The pilot is located on the back right hand side of the burner. The flame must envelope 1/4" of top of the ignitor/sensor and grounding stem. If your pilot assembly does not meet these requirements: • Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise to increase the flame to proper size (see Figure 47, page 22). Do not remove the adjustment screw. • see Troubleshooting, page 25 Pilot Burner Sensing Rod Ignitor/Sensor WARNING: Turn off fireplace and let cool before cleaning. CAUTION: You must keep control areas, burners, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc. GLASS DOOR WARNING: Handle glass door panel with care. Do not strike, slam, or otherwise abuse glass. Do not operate fireplace with the glass door removed, cracked, or broken. WARNING: Do not use abrasive cleaners as this may damage glass. Use a nonabrasive household glass cleaner to clean glass. Do not clean glass when hot. Figure 49 - Correct Pilot Flame Pattern BURNER FLAME PATTERN Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions. If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after installation to ensure proper installation and performance. Figure 50 shows a typical flame pattern. If burner flame pattern differs from that described: • turn fireplace off (see To Turn Off Gas to Appliance, page 22) • see Troubleshooting, page 25 Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, nonabrasive household cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door on page 18 of this manual when removing glass door for cleaning. WARNING: Only parts supplied by the manufacturer should be used when replacing broken or damaged glass door panel (see Replacement Parts, page 27). This glass door panel is a complete unit. No substitute materials may be used. CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass. If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 18). Vacuum all glass pieces with a shop vac. CAUTION: Do not vacuum if pieces are hot. Figure 50 - Typical Flame Pattern Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page 27 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 18 for instructions for replacing glass door. WARNING: Do not operate fireplace with the glass door removed, cracked, or broken. 111924-01D www.desatech.com 23 Cleaning and Maintenance Venting system Continued pilot and burners • Remove ember material before cleaning burners and replace when cleaning is complete. • Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint. • Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint. logs • If you remove logs for cleaning, refer to Installing Logs, Lava Rock, and Glowing Embers, page 20, to properly replace logs. • Use a vacuum cleaner to remove any carbon buildup on logs. • Replace log(s) if broken. See Replacement Parts on page 27. • Replace ember material periodically as needed. See Replacement Parts on page 27. 24 Conduct annual inspection of the venting system following these guidelines: 1. Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced immediately by a qualified service person. 2. Remove the vent cap and shine a flashlight into the vent. Remove any foreign material. 3. Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many elbows, or exterior portions of the system being exposed to cold weather. 4. Inspect joints to verify that no pipe section or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity. www.desatech.com 111924-01D Troubleshooting WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean pilot. This can damage pilot unit. Note: All troubleshooting items are listed in order of operation. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Ignitor will not spark or pilot will not light 1. No gas supply, or shutoff valve is OFF 1. Check to see if you have gas supply and that equipment shutoff valve is opened 2. Repeat lighting procedure several times to purge all air out of lines. If after repeated attempts appliance does not light, call for qualified service and repair. 3. Remove debris and dirt, inspect and clean any other possible obstructions 4. Contact your gas supplier to check pressure 5. Have a qualified technician replace pilot line 6. Replace control valve (Refer to Replacement Parts, page 27) 7. Check that main power is on and that all wire connections are made correctly to the ignition model (see Wiring Diagram, page 21). Check for 24 VAC at the secondary side of the transformer. If 24 VAC is present, and the module does not operate, have the module replaced otherwise have the transformer replaced. 8. Open vent damper until fully locked in OPEN position 2. Air in gas line 3. Construction debris clogging pilot orifice 4. Low gas pressure 5. Kinked pilot line 6. Control valve knob is not opening 7. No power to unit or the ignition module or power transformer is bad 8. Vent damper not fully open Pilot will not stay lit 1. Loose wiring on ignitor wire to ignition module and/or poor ground to ignition module 2. Pilot flame too low to sense 1. Check wiring connection. Refer to Wiring Diagram, page 21, and/or check ground wire to ignition module 2. Clean and adjust pilot burner and check gas supply and inlet pressure to unit Note: Have a qualified technician replace pilot assembly if broken or corroded No gas to burner, although wall switch and valve are set to the ON position 1. Wall switch wires defective or too long 1. Check electrical connections Frequent pilot outage 1. Pilot flame may be too low, causing safety pilot to “drop out” 2. Improper venting or excessive blockage 1. Clean and adjust pilot flame for maximum flame impingement on thermopile 2. Have the vent system inspected, including the termination cap. Remove any restriction or obstruction 111924-01D www.desatech.com 25 TROUBLESHOOTING Continued WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. • • • • OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Fireplace produces a clicking/ticking noise just after burner is lit or shut off 1. Metal expanding while heating or contracting while cooling 1. This is normal with most fireplaces. If noise is excessive, contact qualified service person Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing 1. Problem will stop after a few hours of operation Gas odor even when control knob is in OFF position 1. Gas leak. See Warning statement at top above 2. Control valve defective 1. Locate and correct all leaks (see Checking Gas Connections, page 17) 2. Replace control valve Gas odor during combustion 1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top above 1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Connecting Fireplace to Gas Supply, page 17) Glass soots 1. Flame impingement on logs 1. Adjust the log set so that the flame does not excessively impinge on it 2. Inspect the opening at the base of the burner to see that it is NOT packed with any type of material 2. Debris around burner air mixer Dark residue on logs or inside of fireplace 1. Improper log placement 2. Air holes at burner inlet blocked 3. Burner flame holes blocked 4. Improper venting or excessive blockage 5. Excessive amounts of embers and pan material 26 www.desatech.com 1. Properly locate logs (see log placement sections on page 20) 2. Clean out air holes at burner inlets. Periodically repeat as needed 3. Remove blockage or replace burner 4. Have the vent system inspected, including the termination cap. Remove any restrictions or obstruction 5. Clear excess embers until a minimum gap of 1/2" remains under the grate 111924-01D Replacement Parts Service Hints Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. When Gas Pressure Is Too Low Parts Under Warranty • burners will have delayed ignition Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA’s Customer Service Department at 1-866-672-6040. When calling DESA, have ready • your name • your address • model and serial numbers of your fireplace • how fireplace was malfunctioning • type of gas used (propane/LP or natural gas) • purchase date Usually, we will ask you to return the part to the factory. Parts Not Under Warranty • pilot will not stay lit • fireplace will not produce specified heat • propane/LP gas supply might be low (propane/LP units only) You may feel your gas pressure is too low. If so, contact your local gas supplier. Technical Service You may have further questions about installation, operation, or troubleshooting. If so, contact DESA’s Customer Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready. You can also visit DESA’s technical service web site at www.desatech.com. Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA at 1-866-672-6040 for referral information. When calling DESA, have ready • model number of your fireplace • the replacement part number Specifications Btu Gas Type Ignition Manifold Pressure Minimum Inlet Supply Pressure Dimension (HxWxD) Fireplace (Actual size of firebox. Measurements do not include nailing flanges or standoffs). Carton Weight, lbs/kg* Fireplace Shipping 111924-01D (V)K36EN SERIES 19,000/27,000 Btu/hr Natural Electronic 3.5" w.c. 5.5" w.c. (V)K36EP Series 18,000/26,000 Btu/hr Propane/LP Electronic 10.0" w.c. 11.0" w.c. 36" x 41" x 21 1/8" 91.4 x 104.1 x 53.7 cm 36" x 41" x 21 1/8" 91.4 x 104.1 x 53.7 cm 38" x 44" x 22" 96.5 x 111.8 x 55.9 cm 38" x 44" x 22" 96.5 x 111.8 x 55.9 cm 165 lbs/75 kg 168 lbs/76 kg 165 lbs/75 kg 168 lbs/76 kg www.desatech.com 27 Illustrated Parts Breakdown MODELS (V)K36EN, (V)K36ENH, (V)k36ep and (v)k36eph 10-9 10-7 10-8 10-5 6 7 10-6 8 10-4 1 10-3 4 9 10-2 11 3 10-1 20 18 14 19 12 13 16 15 17 21 2 5 28 www.desatech.com 111924-01D Parts List MODELS (V)K36EN, (V)K36ENH, (V)k36ep and (v)k36eph This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 27 of this manual. KEY NO. PART NO. 1 2 3 4 5 6 7 8 9 10 10-1 10-2 10-3 10-4 10-5 10-6 10-7 10-8 10-9 11 12 13 14 15 16 17 18 19 20 21 ** ** 108010-01 108010-02 108011-01 108011-02 ** ** ** 109082-01 111958-01 111933-01 111932-01 111961-01 111960-01 111926-01 111929-01 111959-01 111930-01 111962-01 see below see below see below 108719-01 12105 11418 14123 21171 24353 24460 111956-01 111956-02 25487 27253 55240 DESCRIPTION QTY. Firebox Assembly Face Weldment Door Assembly Door Assembly (V Models Only) Top Louver Assembly Bottom Louver Assembly Fireplace Top Fireplace Top Insulation Fireplace Surround Heat Shield Log Set Left Base Log Right Base Log Left Front Log Right Front Log Right Rear Log Middle Crossover Log Left Rear Log Left Crossover Log Right Crossover Log Left Refractory Brick Panel Rear Refractory Brick Panel Right Refractory Brick Panel Screen Rod Screen Push-On Nut Strain Relief Gas Knock-Out Cover Handy Box Assembly Gas Conduit Assembly Burner Assembly (Natural Gas) (See pages 30 and 31) Burner Assembly (Propane/LP Gas) PARTS AVAILABLE - NOT SHOWN Lava Rock/Bag Assy Notice Label Vent Label 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 2 1 1 1 1 1 1 ** Not a field replaceable part. K36EN K36EP VK36EN VK36EP K36ENH K36EPH VK36ENH VK36EPH DESCRIPTION 110989-02 110989-01 111215-02 111215-01 Left Refractory Brick Panel 110991-02 110991-01 111217-02 111217-01 Rear Refractory Brick Panel 110990-02 110990-01 111216-02 111216-01 Right Refractory Brick Panel 111924-01D www.desatech.com QTY. 1 1 1 29 illustrated parts breakdown Burner Assembly MODELS (V)K36EN, (V)K36ENH, (V)k36ep and (v)k36eph 1 12 12 7 6 2 8 9 3 10 12 18 4 19 5 20 17 5 21 12 22 23 16 24 30 25 11 14 15 13 28 27 29 26 30 www.desatech.com 111924-01D PARTS LIST Burner Assembly MODELS (V)K36EN, (V)K36ENH, (V)k36ep and (v)k36eph This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 27 of this manual. 111924-01D KEY NO. PART NO. DESCRIPTION 1 111957-01 Pan Assembly Burner 1 2 111311-01 Grate Base 1 3 111312-01 Burner Base Bottom 1 4 26808 Valve Bracket 1 5 11107 Screw, #10-32 x 1/4 PPH Zinc 4 6 104506-23 Burner Orifice (Natural Gas) 1 QTY. 104506-17 Burner Orifice (Propane/LP Bas) 1 7 11102 2 8 108866-01 Pilot (Natural Gas) 1 108866-02 Pilot (Propane/LP Gas) 1 9 111316-01 Pilot Bracket 1 10 111913-01 Burner Base Gasket 1 11 111310-01 Firebox Bottom 1 12 11165 Screw, #10 x 5/8 HWH Zinc 12 13 26287 Switch Bracket 1 14 14500 Brass Fitting 1 15 111912-01 Tubing Assembly 1 16 14569 Electronic Elec. Valve (Natural Gas) 1 14570 Electronic Elec. Valve (Propane/LP Gas) 1 17 14253 Flex Gas Line 1 18 11186 Screw, #8-32 x 1 Zinc 2 19 110286-01 Ignition Module, Synetek 1 20 11147 Screw, #10-24 x 1/2 PPH MS Blk 2 21 14129 Transformer 24V Class 1 22 17223 Magnet 2 23 11201 Nut, 8-32 Hex Zinc 4 24 23416 Elect. Components Board 1 25 14120 Spade 1/4 Female Connector 4 26 14134 Wire, 18 GA Black 5 27 14126 Wire, 16 GA TFFN/MTW 1 28 14115 Spade toungu connector 1 29 14149 Spade, 1/4 F R/Angle Connector 4 30 108863-01 24" Supply Connector Pug Screw, #8-32 x 3/8 PPH Zinc www.desatech.com 1 31 Accessories NOTICE: All accessories may not be available for all fireplace models. Purchase these fireplace accessories from your local retailer. If they can not supply these accessories, call DESA at 1-866-672-6040. for information. You can also write to the address listed on the back page of this manual. Brick Liner KIT Manual blower Kit - BK Manual variable control blower accessory provides better heat distribution. Complete installation and operation instructions included in this manual. (Not Shown) BL36DA - Textured Refractory BL36DSA - Standard Refractory BL36DHA - Textured Refractory Herringbone BL36DHSA - Standard Refractory Herringbone This brick liner adds a touch of style to your direct-vent fireplace. Complete installation and operation instructions included in this manual. Flexible gas Line connector - GA5081 (Not Shown) For all models. Thermostatically- controlled blower kit - BKT Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instructions included in this manual. (Not Shown) Remote Control Kit - WRC Series (Not Shown) Face/Louver Panel kit wall mounted thermostat control kit - gwmt1 (Not Shown) Propane/natural gas conversion kit PCDE-36C - Propane/LP Gas NCDE-36C - Natural Gas (Not Shown) RLD36 - Rolled Louver, Black FPD36 - Filligree Louver, Black FPD36B - Filligree Louver, Brushed Brass FPD36P - Filligree Louver, Platinum FPD36PB - Filligree Louver, Polished Brass Standard On/Off Electronic Remote Control Kit Allows easy wall access for thermostatic operation of your fireplace. wall mounted ON/OFF Switch - gwmS2 (Not Shown) Allows burner system to be turned on and off with a wall switch. ROLLED Louver Trim kit (Not Shown) LT36B - Brushed Brass LT36P - Platinum LT36PB - Polished Brass Deflection hood (Not Shown) HD36 - Black (2" Brow) Perimeter Trim kit (Not Shown) PT36 - Black PT36B - Brushed Brass PT36P - Platinum PT36PB - Polished Brass 32 www.desatech.com 111924-01D Notes ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ 111924-01D www.desatech.com 33 Warranty Information KEEP THIS WARRANT Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented. This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized retailers of this product and/or DESA who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit. This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner. TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. For information about this warranty write: 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com 111924 01 NOT A UPC 111924-01 Rev. D 03/06
advertisement