EdgeStar AP12000HS Owner's Manual

Add to my manuals
23 Pages

advertisement

EdgeStar AP12000HS Owner's Manual | Manualzz

Portable Air Conditioner

AP12000HS

Owner’s Manual

For more information on other great EdgeStar products on the web, go to http://www.edgestar.com

i

Important Safety Information

Improper handling can cause serious damage to the appliance and/or to the user.

This portable air conditioner is not intended for use by children. Children should be supervised to ensure that they do not play with this product.

Electrical Safety

 This unit is designed for indoor use only.

 Do not use the unit in extremely humid or wet environments.

 Do not wet the housing or control panel.

 Do not pull the unit by the cord.

 Always turn the unit off and unplug it from the socket when cleaning.

 Unplug the unit if it is not going to be used for a long period of time.

 Do not operate the unit with a damaged plug or a loose socket.

 Use only the correct power supply with appropriate amperage.

 If the power cord is damaged, it must be replaced by the manufacturer, a service agent, or qualified technician.

 Do not remove any part of the casing unless instructed by an authorized technician.

General Safety

 This portable air conditioner is not intended to be used by children.

 Do not allow children to play with the controls or drop any objects into the air outlets or vents.

 Do not place objects or let any person sit on top of the unit.

 Only use in the upright position on a flat, level surface and provide at least 20 inches of clearance from any walls or objects.

 Route the power cord carefully to avoid a tripping hazard.

 This unit is intended for domestic use only. Do not use the portable air conditioner for industrial or commercial use. Any other use may invalidate the warranty.

RESET

TEST

Your portable air conditioner is supplied with a Leakage-Current

Detection and Interruption (LCDI) safety plug. This device provides protection to reduce the risk of fire due to arcing faults in the power supply cord. Before using your portable air conditioner, follow the instructions below to ensure that the LCDI plug is working properly:

1. Plug the power cord to a grounded outlet.

2. Press the TEST button on the LCDI plug. This should trip the plug and cut the power to the air conditioner. If the plug does not trip and you are able to turn on the unit, please contact EdgeStar support.

DO NOT USE YOUR PORTABLE AIR CONDITIONER IF THE TEST FAILS.

Press the RESET button to start using your air conditioner.

Do not use the TEST and RESET buttons as an ON/OFF switch.

Table of Contents

IMPORTANT SAFETY INFORMATION ................................................................. I  

INTRODUCTION ................................................................................................... 1  

PARTS IDENTIFICATION ..................................................................................... 2  

B ACK V IEW .......................................................................................................... 2  

F RONT V IEW ........................................................................................................ 2  

INSTALLING THE CARBON FILTER ................................................................... 3  

WINDOW KIT INSTALLATION INSTRUCTIONS ................................................. 4  

P REPARATIONS FOR INSTALLING THE WINDOW KIT .................................................. 4  

I NSTALLING THE GRATED ADAPTER ........................................................................ 5  

I NSTALLING THE WINDOW PLATES .......................................................................... 6  

A

TTACHING THE DUCT CONNECTORS TO THE EXHAUST HOSE

.................................. 7  

C ONNECTING THE DUCT CONNECTOR TO THE UNIT ................................................. 8  

C ONNECTING THE DUCT CONNECTOR TO THE GRATED ADAPTER ............................. 8  

N OTES ABOUT THE E XHAUST HOSE ....................................................................... 9  

CONTROL PANEL OVERVIEW .......................................................................... 10  

OPERATING THE CONTROL PANEL ............................................................... 11  

P OWER ............................................................................................................. 11  

A UTO -R ESTART : ................................................................................................ 11  

C

OOLING

M

ODE

................................................................................................. 11  

D EHUMIDIFYING M ODE ....................................................................................... 11  

H EAT M ODE ....................................................................................................... 11  

F AN O NLY M ODE ............................................................................................... 12  

S

PEED

............................................................................................................... 12  

T IMER ............................................................................................................... 12  

How to set the unit to automatically turn on ................................................ 12  

How to set the unit to automatically turn off ................................................ 12  

LCD D

ISPLAY

.................................................................................................... 12  

W ATER L IGHT .................................................................................................... 12  

USING THE REMOTE CONTROL ...................................................................... 13  

I NSTALLING THE BATTERIES ................................................................................ 13  

R

EPLACING THE BATTERIES

................................................................................ 13  

ENERGY SAVING GUIDE ................................................................................... 14  

MAINTENANCE .................................................................................................. 15  

C LEANING THE UNIT ........................................................................................... 15  

C

LEANING THE PRE

-

FILTER

................................................................................. 15  

P REPARATION FOR S TORAGE ............................................................................. 15  

TROUBLESHOOTING ........................................................................................ 16  

T ROUBLESHOOTING CONTINUED ......................................................................... 17  

SPECIFICATIONS ............................................................................................... 18  

EDGESTAR LIMITED WARRANTY ................................................................... 19  

EdgeStar Portable Air Conditioner ii

1

Introduction

Thank you for purchasing this EdgeStar portable air conditioner. We are glad you chose us. We believe that your purchase of this product opens a relationship between you and EdgeStar. We will provide the customer support needed to nurture that relationship.

This manual contains important information regarding the proper installation, use and maintenance of your portable air conditioner. Following this manual will ensure that your product will work at its peak performance and efficiency.

Please save the original product packaging in case you need to safely transport your portable air conditioner.

For Your Records:

Please write down the model number and serial number below for future reference. Both numbers are located on the ratings label on the back of your unit and are needed to obtain warranty service. You may also want to staple your receipt to this manual as it is the proof of your purchase, and is also needed for service under your warranty.

Model Number:

Serial Number:

Date of Purchase:

To better serve you, please do the following before contacting customer service:

 If you received a damaged product, immediately contact the dealer that sold you the product.

 Read and follow this instruction manual carefully to help you install, use and maintain your portable air conditioner.

 Read the troubleshooting section of this manual as it will help you diagnose and solve common issues.

 Visit us on the web at http://www.edgestar.com for product guides, additional troubleshooting resources and up-to-date information. If you need service, our friendly customer service representatives are available via email at [email protected] or by telephone at 1 (866) 319-

5473.

Front View

Parts Identification

Control Panel

Front Air Vent

Handle

Caster

Back View

Pre-filter

Air Intake

Exhaust Outlet

Power Cord

EdgeStar Portable Air Conditioner

Drain Valve

2

3

CAUTION: Never operate the air conditioner without the pre-filter attached.

Filter frame

Pre-filter

Installing the Carbon Filter

Your portable air conditioner ships with a pre-filter and an activated carbon filter. The carbon filter will help remove contaminates and odors from the air. It is recommended you replace the carbon filter every two to three months, or as needed. It is necessary to clean the pre-filter periodically. Follow the steps below to install the carbon filter:

1. Pull the handle on the pre-filter straight up.

Activated carbon filter

2. Separate the filter frame from the pre-filter.

3. Place the activated carbon filter on the pre-filter.

4. Reattach the filter frame.

5. Insert the assembled pre-filter into the back of the unit

Preparations for installing the window kit

NOTE: Exhaust Covers may be attached to the

Grated Adapters. You may need to twist and pull apart to separate them.

NOTE: You may need to contact your electrician if your room’s circuit is not able to power your unit.

Window Kit Installation Instructions

You must vent your portable air conditioner when running in it cooling mode. Your unit includes a window exhaust kit that can be used to vent the unit out a window.

Before you begin, make sure you have all the parts necessary for installation.

Window Kit Parts List:

4 Screws 1 Grated Adapter

1 Exhaust Cover

1 Exhaust Hose

2 Duct Connectors

1 Window Kit Plate with Hole

1 Window Kit Plate

If you have multiple windows, choose one that is near an electrical outlet that will be able to provide sufficient power to your unit. See the power requirements listed on the product label printed on the side, or on the back of your portable air conditioner.

Your window kit can be installed on a horizontal or vertical sliding window as shown in the following pictures:

20”

Follow the instructions on the next pages to install the window kit.

EdgeStar Portable Air Conditioner 4

5

Installing the grated adapter

1. Insert the round grated adapter through the back grooved side of the window kit plate with hole.



2. Secure the grated adapter by fastening the screws from flat side of the window kit plate to the holes on the grated adapter.

Installing the window plates

3. Open your window and place the window kit with grooved side facing outward on the window sill. Then, slide the window kit plate to fit the width of the window. You can use screws to secure the window kit plate from sliding. locks.



CAUTION: Secure your

4. Lower the window to secure the window kit in place. You may need to use duct tape to better secure the window kit. window by using window locks. Please contact your dealer to purchase window

EdgeStar Portable Air Conditioner 6

7

Attaching the duct connectors to the exhaust hose

A.



B.

5. Attach the connectors to the hose:

A. Extend the ends of the exhaust hose

B. Thread the duct connector on by turning it clockwise until it stops.



20”

6. Roll the unit towards the window kit. Leave a space that is at least 20 inches to the wall.

Connecting the duct connector to the unit

7. Align the slots on the duct connector to the tabs and snap into the back of the unit.

Connecting the duct connector to the grated adapter



8. Align the slots on the duct connector to the tabs on the grated adapter and snap in place.

After you have installed the exhaust hose and window kit, you can plug in your portable air conditioner and start using it.

EdgeStar Portable Air Conditioner 8

Notes about the Exhaust hose

Your portable air conditioner is designed to exhaust condensate water that is collected from the air. This water, in either gaseous or droplet form, will be expelled out the exhaust port of the unit.

Please take this into account when deciding how to vent it.

1. The exhaust hose supplied with the portable air conditioner can be extended up to 48 inches; however for maximum efficiency, use the shortest length possible.

2. Try to prevent any kinks or bends in the exhaust hose. Kinks or bends may trap exhaust air which can radiate heat into the room or potentially cause the portable air conditioner to overheat and shut itself off.

3. The exhaust hose supplied with the portable air conditioner has been specifically designed for this air conditioner. Do not lengthen the hose by adding additional hoses or attachments or replace it with any other hose.

Do not lengthen the exhaust hose by adding additional hoses or attachments.

Warning: Longer hoses are not recommended.

Draining the Unit

When the portable air conditioner is in cooling mode, dehumidify mode, or heating mode, it will remove moisture from the air. The condensed water from the air will be collected in an internal reservoir and will be evaporated and exhausted out of the exhaust hose. However, in very humid conditions, the internal reservoir may fill completely. This causes the air conditioner to turn off to avoid overflowing the internal reservoir. The WATER indicator will light up on the Control Panel.

Direct drainage

1. Remove the rubber drain plug from the drain port.

2. Connect a drain hose to the drain port.

The portable air conditioner will now drain through the drain hose.

Please note that this unit has no drain pump; all water will drain with gravity only, i.e., only “downhill.”

9

Control Panel Overview

Indicator Lights LCD Display

EdgeStar Portable Air Conditioner

WATER

Cooling High

Dehumidify Medium

Fan Only Low

POWER Mode Speed

Timer

Timer

Power Button

Mode Button

Speed Button

Infrared Sensor

Timer Button

Up Button

Down Button

Button Function

Power Powers the unit on or off.

Mode

Speed

Timer 

 (Up)

 (Down)

Changes between cool, dehumidify heat and fan modes. The indicator light will turn on next to the mode you set. Heating mode will have a red indicator light

Sets the fan speed. The High, Medium, or Low indicator light will turn on next to the fan speed you set.

Used to enable the timer.

Increases the set temperature or the time when the Timer button is enabled.

Decreases the set temperature or time when the Timer button is enabled.

Indicator Function

Water Light The water light will turn on if the unit has filled the internal water reservoir.

Timer Light The timer light indicates you have set the timer. Use the Up and Down buttons to set the number of hours.

LCD Display The LCD can display the ambient temperature, set temperature, and the number of hours when setting the timer.

Infrared

Sensor

Receiver for the remote control.

10

Power

Cooling Mode

NOTE: The exhaust hose must be used in Cooling mode in order to cool a room.

Dehumidifying Mode

Operating the Control Panel

Use the Power button to turn the portable air conditioner on and off.

By default when you first use the power button, the unit will begin to operate in cooling mode. The unit will remember the last used mode/settings if you shut down and restart.

Auto-Restart: If power to the unit is interrupted, the air conditioner will restart itself in its last used mode/settings once power is restored. The compressor will restart after 3 minutes.

Cooling mode cools and dehumidifies the air. If the ambient temperature drops below the temperature you selected, the compressor turns off and the unit functions with the fan only. When the temperature rises above the temperature you selected, the compressor turns on again.

To operate the unit in cooling mode:

1) Make sure the power cord is plugged into a power outlet.

2) Press the Power button.

3) Press the Mode button until the LED indicator next to “Cooling” lights up.

4) Select the fan speed by using the Speed button.

5) Set the thermostat by using the Up and Down buttons. The thermostat is adjustable between 61°F - 89°F in one degree increments.

During the Dehumidifying mode, the unit will condense water out of the air and exhaust it through the exhaust hose. The ambient temperature in the room will probably drop by a few degrees while using the Dehumidifying mode.

To operate the unit in dehumidifying mode:

1) Make sure the power cord is plugged into a power outlet.

2) Press the Power button.

3) Press the Mode button until the LED indicator next to “Dehumidify” lights up.

NOTES: If the room temperature is below 77ºF, the fan will always run on low speed while in the

Dehumidifying mode. If you do not use the exhaust hose in Dehumidifying mode, you must manually drain the water from the unit. Additionally, the ambient temperature in the room will probably rise by a few degrees if you do not use the exhaust hose. You will be not be able to change the thermostat temperature while in Dehumidifying Mode.

Heat Mode Your air conditioner can work as a heat pump. It must be vented for it to expel the cold air out the exhaust.

To operate the unit in heat mode:

1) Make sure the power cord is plugged into a power outlet.

2) Press the Power button.

3) Press the Mode button until the LED indicator next to “Fan” lights up red. The thermostat is adjustable between 61°F - 77°F.

11

Fan Only Mode

NOTE: Fan Only mode does not require that the exhaust hose be attached.

Speed

Timer

Fan Only mode is used to circulate the air in your room. No temperature setting is needed.

To operate the unit in Fan Only mode:

1) Make sure the power cord is plugged into a power outlet.

2) Press the Power button.

3) Press the Mode button until the LED indicator next to “Fan Only” lights up.

4) Press the Speed button to select the fan speed. You can choose between High, Medium and Low. The LED indicator next to the speed will light up.

The Speed button is used to change the fan speed while in Cooling and Fan Only modes.

Press the Speed button to select the fan speed. The LED indicator light next to the High, Medium or Low will light up.

The timer can be used to either turn the unit on or off after a number of elapsed hours. The timer is adjustable between 1-12 hours in one hour increments.

How to set the unit to automatically turn on

:

1) Press the Timer button while the unit is powered off. The Timer indicator LED will light up

2) Use the Up and Down buttons to set the time (displayed in hours). After the selected time passes, the unit will automatically turn on.

How to set the unit to automatically turn off

:

NOTE: To cancel the timer, press the Timer button or Power button.

LCD Display

1) Press the Timer button while the unit is powered on. The Timer indicator LED will light up

2) Use the Up and Down buttons to set the time (displayed in hours). The unit will automatically turn off after the selected time elapses.

The LCD Display will show the ambient temperature by default.

Pressing the Up and Down buttons will show the set temperature for 15 seconds, and then revert to the room temperature. You can switch between Fahrenheit and Celsius by pressing both the Up and Down Buttons simultaneously. The displayed range of the ambient temperature is from 0º to 99º. Temperatures above 99º will be displayed as “Hi”, and temperatures below 0º will be displayed as “Lo”. If you enabled the Timer, the LCD Display will show the hour(s) set.

In high humidity situations, the internal water reservoir may fill. The

Water Light

EdgeStar Portable Air Conditioner unit will automatically shut off and the water light will turn on. Once the water is manually drained, the unit will operate normally.

12

NOTES: Be careful not drop the remote control. Do not place the remote control in a location exposed to direct sunlight.

Using the Remote Control

The remote control can be used instead of the control panel to remotely operate your portable air conditioner. The functions on the remote are the same as on the control panel.

Power Button

Speed Button

Timer Button

Mode Button

Up and Down

Buttons

Button Function

Power Powers the unit on or off.

Mode

Speed

Timer

(Up)

(Down)

Changes between cool, dehumidify, heat and fan modes.

Sets the fan speed between high, medium, or low.

Used to enable the timer.

Increases the set temperature or the time when the

Timer button is enabled.

Decreases the set temperature or time when the

Timer button is enabled.

Installing the batteries

1) Remove the cover on the back of the remote control.

2) Insert the batteries with the (+) and (-) ends pointing in the correct direction.

3) Slide the cover back on.

CAUTION: Use only AAA batteries. Remove the batteries if the remote control will not be used for one month or longer. Do not attempt to recharge batteries not designed to be recharged. All batteries should be replaced at the same time. Do not mix old and new batteries. Do not dispose of batteries in a fire as they may explode.

13

Energy Saving Guide

Read and follow the guide below to get the best performance and efficiency from your portable air conditioner:

 Do not cover the air outlet (exhaust) while in use.

 Do not place the unit in front of curtains or drapes- to ensure they do not obstruct the air intake.

 Minimize the length of the exhaust hose.

 Make sure the exhaust hose is as straight as possible and avoid kinks or bends.

 Keep curtains, blinds or drapes closed during the sunniest part of the day.

 Use the timer to operate the unit before it is needed. For example, set the timer to turn on the unit in cooling mode for 3 or more hours to cool the room before you arrive. You may want to operate the unit all day if you live in a warmer climate.

 Minimize the heat sources (direct sunlight, computers, servers, people, etc.) in the room.

 Close all windows and doors.

 Use the unit in a contained room. For example, a room with four walls and a ceiling, instead of a partitioned studio, or warehouse.

 Make sure the unit is on a level surface.

 Minimize the amount of humidity in the room. For example, run the unit as a dehumidifier.

 To prolong the compressor's life, please wait at least 3 minutes before turning the unit back on after shutting it off.

 Inspect and keep the pre-filters clean by cleaning regularly.

 Inspect and replace the activated carbon filters regularly.

 Perform

EdgeStar Portable Air Conditioner 14

Cleaning the unit

Cleaning the pre-filter

NOTE: The activated carbon filter is not washable. You should replace it every 2-3 months or as needed. Contact

EdgeStar retailers for replacement filters.

Preparation for Storage

Maintenance

Clean the air conditioner and filters regularly to maximize performance and efficiency, and prolong the unit’s life. Be sure to always unplug the air conditioner from the power outlet before cleaning.

Use a soft dry cloth to wipe the body clean. If necessary, use lukewarm water to dampen a cloth to clean the unit.

Use a soft bristle brush to clean between the vents.

Carefully use a vacuum cleaner to clean the condenser coils

Never use abrasive chemicals, volatile substances, gasoline, detergents, chemically treated cloths, or other cleaning solvents that may damage the cabinet exterior.

Never spray water directly on the unit.

To clean the pre-filter, follow the steps below:

1) Power off the unit and remove the pre-filter.

2) Remove the activated carbon filter.

3) Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt, then rinse thoroughly under lukewarm running water

(below 104°F). You may use a mild soap and water solution if needed. Allow the pre-filter to air dry in a cool and shaded place.

Dry thoroughly before reinstalling.

Clean the pre-filter periodically. If the unit is used in a dusty environment you may need to clean it on a weekly basis.

Warning: Never operate the unit without the filters.

If you are not going to be using the unit for an extended period of time, follow the instructions below before storing your unit:

1) Drain all the water from the unit’s reservoir. Operate the unit in fan mode for a few hours to thoroughly dry any moisture left on the coils inside the unit.

2) Power off the unit, and clean or change the filters.

3) Unplug and carefully wind the power cord.

4) Remove the exhaust hose and duct connectors and keep them in a safe place.

15

Troubleshooting

Follow the troubleshooting guide below to resolve common issues.

My air conditioner is not functioning at all

My remote control does not work and the indicator light on remote does not turn on

My air conditioner is making a loud noise

My air conditioner is making a continuous metallic knocking or pinging sound

My air conditioner is leaking

My air conditioner runs for a little while and then it trips the power cord or the circuit breaker

The control panel lights blink randomly

Unit is not receiving power

LCDI power cord is tripped

Insufficient power

Make sure the unit is plugged in

Press the Reset button on the LCDI cord

Move the unit to another outlet. Check your circuit breaker.

(Refer to the rating label on the back of the unit to determine the Amperage draw)

Water reservoir is full Drain the unit and restart

Control panel is disconnected

If no indicator lights turn on, contact customer service

Batteries not installed Install new batteries

Bad batteries Replace the batteries

Batteries installed incorrectly

A defective remote control

The unit is not level.

A foreign object has jammed the fan.

The floor below the unit is uneven

Reinstall the batteries correctly

Contact customer service

Make sure the unit is on a level surface

Remove the object from the fan

Move the unit to a level surface

Unit may have been shipped on its side

Shut off the unit. Let the unit sit on a level surface for at least 24 hours and restart.

Damaged compressor Contact customer service

Drain plug is removed Attach the drain plug

Cracked base pan Contact customer service

The air conditioner may be plugged into an outlet that can not supply the correct amount of current

Unit may have a faulty control panel

Contact an electrician if the unit works in a different room or circuit

Contact customer service

EdgeStar Portable Air Conditioner 16

NOTE: If the ambient temperature is above 90°F the unit may not blow cold air.

TIP: Run the unit before it is needed. For example, run the unit in the morning before the area gets hot, and continue to run the unit all day long in order to maintain a low temperature.

Troubleshooting continued

My air conditioner is not cooling at all

My air conditioner blows cold air, but does not lower the room temperature

Unit is not operating in cooling mode

The compressor is not on

The ambient temperature is too high

Set the unit to be in cooling mode, and lower the set temperature (pg. 11)

The compressor may take up to 3 minutes to turn on, or longer if it is too warm

Lower the room temperature to be below 90°F degrees

The filter may be dusty or blocked

Clean the filters.

(pg. 15)

Blocked exhaust port Remove any obstructions in the exhaust hose and port

The unit is not vented The unit must be vented. (pg. 4)

The area of the room is too large

Minimize the size of the area to be cooled, i.e. adding a drop ceiling. Use more than one unit to cool the area, or use a larger unit

Open windows and doors

Too many heat sources

The room/garage may be inadequately insulated

The ambient temperature is too high

Close any open doors and windows

Remove or shut off additional heat sources such as radio equipment, servers, etc.

Properly insulate the room to be cooled, i.e. using fiberglass

Direct sunlight is heating the room

The unit may not work if the room temperature is above

90°F

Close curtains or pull down blinds, and minimize the direct sunlight into the room

The filter may be dusty or blocked

Clean the filter and replace it if needed

Dirty condenser coils Carefully vacuum the coils clean

Obstructed air intake or exhaust ports

Remove anything blocking the ports

17

Specifications

Description of product Portable Air Conditioner

Model AP12000HS

Input Power 950W

Current 8.0A

Color Silver

Dehumidifying capacity 81 Pints/Day

Coolant R22

Dimensions

WxHxD

17 1/10” 30 9/10” x15”

EdgeStar Portable Air Conditioner 18

EdgeStar Limited Warranty

One (1) Year Parts & Ninety (90) Days Labor

This product is warranted by EdgeStar to be free from defective workmanship and materials, subject to any conditions set forth as follows:

WHAT IS COVERED:

LABOR: For a period of NINETY (90) DAYS from the date of original purchase, labor will be performed free of charge at an authorized EdgeStar repair facility. At its option, EdgeStar will repair the product with new or remanufactured parts, or exchange the defective product with a new, refurbished, or remanufactured product. If a product is replaced, it will carry the remaining warranty of the original product. After the ninety (90) day period, EdgeStar will no longer be responsible for labor charges incurred. All defective products and parts covered by this warranty will be repaired or replaced on a mail-in basis to an EdgeStar authorized repair facility.

PARTS: For a period of ONE (1) YEAR from the date of original purchase, EdgeStar will supply new, rebuilt, or refurbished parts free of charge. EdgeStar may request a defective part be returned in exchange for the replacement part. All replacement parts or products will be new, remanufactured, or refurbished. All products and parts replaced by

EdgeStar under warranty service become the property of EdgeStar.

This warranty applies to the original purchaser only, and only covers defects in workmanship experienced during operation of the product under normal service, maintenance, and usage conditions. This warranty applies to the purchase and use of this product in residential settings within the United States of America.

WHAT IS NOT COVERED:

The following limitations apply to the coverage of this warranty. This warranty does not cover:

Labor charges for installation, setup or training to use the product.

Shipping damage, and any damage caused by improper packaging for shipment to an authorized service center, and any damaged caused by improper voltage or any other misuse, including abnormal service, handling, or usage.

Cosmetic damage such as scratches and dents.

Normal wear and tear on parts or replacement of parts designed to be replaced, e.g. filters, cartridges, batteries.

Service trips to deliver, pick-up, or repair, install the product, or to instruct in proper usage of the product.

Damages or operating problems resulting from misuse, abuse, operation outside environmental specifications, uses contrary to instructions provided in the owner’s manual, accidents, acts of God, vermin, fire, flood, improper installation, unauthorized service, maintenance negligence, unauthorized installation or modification, or commercial use.

Labor charges incurred 91 days or more after the date of original purchase.

The use of EdgeStar products in commercial settings.

Optional accessories, attachments, and appearance items.

Products that have been modified to perform outside of specifications without the prior written permission of EdgeStar.

Products lost in shipment, or theft.

Products sold AS IS or from an unauthorized reseller.

Products that have had their serial numbers removed or defaced. Products with serial numbers that have been invalidated.

OBTAINING WARRANTY SERVICE:

If you believe your product is defective, contact EdgeStar Customer Support for troubleshooting assistance and warranty service at 1-866-319-5473. Please have your serial number and proof of purchase available. Once an

EdgeStar authorized representative has confirmed that your product is defective and eligible for warranty service, the product must be returned to an EdgeStar repair facility. The purchaser is solely responsible for prepaying all shipping related costs to and from the repair facility. EdgeStar is not responsible for damage resulting from shipper mishandling or improper packaging. Do not return a defective product to the place of purchase. Products received without a return authorization number will be refused.

THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY

WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TO THE EXTENT ANY IMPLIED

WARRANTY IS REQUIRED BY LAW, IT IS LIMITED IN DURATION TO THE EXPRESS WARRANTY PERIOD ABOVE. NEITHER

THE MANUFACTURER NOR ITS DISTRIBUTORS SHALL BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL, INDIRECT,

SPECIAL, OR PUNITIVE DAMAGES OF ANY NATURE, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR PROFITS,

OR ANY OTHER DAMAGE WHETHER BASED IN CONTRACT, TORT, OR OTHERWISE. SOME STATES DO NOT ALLOW THE

EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU.

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY HAVE OTHER RIGHTS THAT VARY FROM STATE TO

STATE.

19

EdgeStar Products

Box 81336

Austin, TX 78708-1336

Toll Free: 1-866-319-5473

Web: http://www.edgestar.com

E-mail: [email protected]

Register your product, download owner’s manuals, access additional troubleshooting resources, and obtain more information on other great

EdgeStar products on the web at: http://www.edgestar.com

Product contents and specifications may change without notice.

Copyright © 2009 Living Direct, Inc.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals