BOULEVARD™
MONOBLOCK LAVATORY FAUCET with
Speed Connect™ Drain
Installation
Instructions
7431.101
Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on
American Standard faucets.
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
Certified to comply with ANSI A112.18.1
M 9 6 8 6 4 1
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended tools
Adjustable Wrench Tubing Cutter Screwdriver
1
INSTALL FAUCET
CAUTION
Channel Locks
Turn off hot and cold water supplies before beginning.
Seat SEAL (1) into under side of ESCUTCHEON RING (2).
Seat ESCUTCHEON RING (2) with collar facing up into groove in faucet base.
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through ESCUTCHEON RING (2) and the mounting hole of lavatory or mounting surface. Figure A.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6), pulling faucet to front of sink, so SUPPLIES (3) rests against mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5).
Figure B.
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6) to complete faucet mounting.
Figure A
GROOVE
(FAUCET
BASE)
4
2
1
MOUNTING
SURFACE
COLLAR ON
MOUNTING NUT
6
4
Figure B
7
5
3
5
8
1
2
POP-UP DRAIN
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig. B.
3
REMOVE FLANGE
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
Fig. A.
1
Fig. A.
1
3
2
2
4
3
Fig. B.
Fig. B.
DRAIN
BODY
4
4
INSTALL DRAIN FROM
BELOW FIXTURE
From under side of SINK install DRAIN BODY (1) up through drain outlet.
Note: No plumber’s putty or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body from above SINK and tighten
FLANGE (4) firmly.
4
3
6
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed and not visible. Fig. A.
POP-UP KNOB (1) must be fully down. Fig. B.
REAR OF SINK
5
TIGHTEN LOCKNUT
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
DRAIN
OUTLET
1
1
2
Fig. A.
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
DOWN
1
M 9 6 8 6 4 1
2
7
ATTACH CABLE CONNECTOR
Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig. A.
Your new POP-UP DRAIN installation is now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
Fig. A.
1
Fig. B.
2
1-1/4” O.D.
8
CHECK OPERATION OF POP-UP
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes.
Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.
1
2
9
MAKE WATER SUPPLY AND WASTE CONNECTIONS
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect left SUPPLY (1) to Hot (Marked with a Red Band) and right supply to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet.
APPROX. 20"
1
HOT
RED
BAND
2
BLUE
BAND
3/8" COMPRESSION
COLD
M 9 6 8 6 4 1
3
10
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal and retains water in Sink. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions.
Release POP-UP KNOB (4) down and check all drain connections and "P" trap for leaks. Tighten if necessary.
4
5
ON
1
OFF
COLD
HOT
3
WASTE
OUTLET
11
SERVICE
CAUTION
To remove or replace cartidge
Turn off hot and cold water supplies before beginning.
Turn valve to OFF position.
Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2).
Pull off HANDLE (3) and CAP (4).
Unthread CARTRIDGE NUT (5) and remove.
Pull out CARTEIDGE (6).
Inspect CARTRIDGE (6) and O-RINGS (7) for debris and clean if necessary.
Clean MANIFOLD (8) and rinse clean.
Reinstall CARTRIDGE (6) and O-RINGS (7) onto MANIFLOD (8).
Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3).
If spout drips, operate handle several times from OFF to ON and HOT to
COLD position. Do not force - handles turn only 90˚.
2
1
“P” TRAP
2.5mm HEX KEY
2
REMOVE
3
INSTALL
4
5
2
6
7
8
12
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
4
M 9 6 8 6 4 1
Speed Connect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
Fig. A. Fig. B. Fig. C.
DOWN
CAM 1
RE-ATTACH
1
CAM CAP
DISCONNECT
2
STOPPER
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
Fig. D. Fig. E.
REMOVE
CAM
Fig. F.
REMOVE
CAM CAP
M 9 6 8 6 4 1
5
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be in “Locked” mode and not be removable.
LOGO
LOOP TOWARD
REAR OF SINK
DRAIN
Locked Mode
(Vandal Proof)
Fig. G.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable .
LOGO
180˚
LOOP TOWARD
FRONT OF SINK
DRAIN
Unlocked Mode
Fig. H.
Fig. J.
INSTALL CAM
CAM
Fig. K.
INSTALL
CAM CAP
M 9 6 8 6 4 1
6
BOULEVARD™
MONOBLOCK
LAVATORY FITTING
MODEL NUMBER
7431.101
PLUG
BUTTON
SCREW
M962828-YYY0A
HANDLE KIT
607641-YYY0A
CARTRIDGE CAP
603275-0070A
CARTRIDGE NUT
M951472-0070A
CARTRIDGE
Replace the "YYY" with appropriate finish code
CHROME
SATIN NICKEL
002
295
M962829-YYY0A
POP-UP ROD
M962492-0070A
MOUNTING KIT
M918462-0070A
CABLE ADAPTER
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN MEXICO 01-800-839-1200
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
© AS America,Inc. 2009
AERATOR
M962421-YYY0A
ESCUTCHEON KIT
M922881-YYY0A
M952425-YYY0A
DRAIN ASSEMBLY
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
M962544-YYY0A
STOPPER
ASSEMBLY
M952430-0070A
CABLE ASSEMBLY
M962457-007A
FLANGE
ASSEMBLY
M922872-0070A
CAM SEAT INSERT
M962552-0070A
CAM ASSEMBLY
M913207-0070A
TAILPIECE INSERT
A919661-0020A
TAILPIECE
M962458-0070A
DRAIN MOUNTING KIT
M 9 6 8 6 4 1
7