WIRELESS SMOKE DETECTOR

EWF1CO

WIRELESS SMOKE & CO DETECTOR

USER GUIDE

V2.0

FR ES PT

COMPLIES WITH EN 14 604:2005

EN

FR

ES

PT

EWF1 is a wireless smoke detector; EWF1CO is a wireless carbon monoxide

(CO) detector combined with smoke detector. In case of smoke detection or carbon monoxide level increase, EWF1/EWF1CO will indicate the alarm and notify

ELDES system about the event.

EWF1 est un détecteur de fumée radio; EWF1CO est un détecteur de monoxyde de carbone (CO) radio. En cas d’augmentation du niveau de fumée ou de monoxyde de carbone, EWF1/EWF1CO va alerter le système Eldes de cet

événement.

EWF1 es un detector de humo inalámbrico; EWF1CO es un detector de monóxido de carbono (CO) inalámbrico combinado con el detector de humo. En caso de que se produzca la detección del aumento de humo o monóxido de carbono, EWF1/EWF1CO indicará la alarma y notificará al sistema ELDES sobre el evento.

EWF1 é um detector fotoelétrico de fumaça sem fios; EWF1CO é um detector fotoelétrico de fumaça e monóxido de carbono (CO) sem fios. Quando a concentração de fumaça/CO ultrapassa um determinado nível, EWF1/EWF1CO acionará o alarme e notificará o sistema ELDES quanto ao evento.

4 EN | FR | ES | PT EWF1-EWF1CO

MIN

+5°C(41°F)

MAX

+45°C (113°F)

MIN

+5°C(41°F)

MIN

+5°C(41°F)

MAX

+45°C (113°F)

MAX

+45°C (113°F)

0,9m

(2.95 ft)

0,9m

(2.95 ft)

1

2

1

2

1

2

2

2

1

2

1

1

1

2

1

2

2

1

3 MIN.

WAIT FOR 3 MIN.

ATTENDRE 3 МИН.

ESPERE POR 3 MIN.

AGUARDE 3 MIN.

EWF1-EWF1CO

TEST

PRESS FOR 2 SEC.

PRESSER PENDANT 2 SEC.

PRESIONE DURANTE 2 SEG.

PRESSIONE POR 2 SEG.

1

2

ELDES

Configuration

Tool

EN | FR | ES | PT 7

EN

1. PLACEMENT

1. Place the detector as close as possible to the center of the ceiling. If not possible, mount no closer than 10cm (0.33ft) from a wall or corner. Also, if local codes allow, install the detectors on walls, between 10 and 30cm (0.33 and 0.98ft) from ceiling/wall intersections.

2. Install a minimum of two units in every house, no matter how small the house is.

3. Place a detector in each room that is divided by a partial wall.

For best protection we recommend that you install a detector in every room.

DO NOT place EWF1/EWF1CO in the following locations:

• Near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces, hot water heaters). Use specialized detector with unwanted alarm control for this areas.

• In areas with high humidity, like bathrooms or areas near dishwashers or washing machines.

Install at least 3m (9.84ft) away from these areas.

• Near air returns or heating and cooling supply vents. Install at least 1m (3.28ft) away from these areas. The air could blow smoke away from the detector, interrupting the alarm.

• In rooms where temperatures may fall below +5°C (+41°F) or rise above +45°C (+113°F).

• In extremely dusty, dirty, or insect-infested areas where loose particles interfere with the detector operation.

Incorrect placement will result in the decrease of operational effectiveness.

8 EN EWF1-EWF1CO

2. WHAT SHOULD I KNOW

2.1 CARBON MONOXIDE (CO) POISONING

Carbon monoxide is a product of incomplete combustion of organic matter. It is a toxic gas, but, being colorless, odorless, tasteless, and initially non-irritating, it is very difficult for people to detect.

CONCENTRATION

35 ppm (0.0035%)

100 ppm (0.01%)

200 ppm (0.02%)

400 ppm (0.04%)

800 ppm (0.08%)

1,600 ppm (0.16%)

SYMPTOMS

Headache and dizziness within six to eight hours of constant exposure

Slight headache in two to three hours

Slight headache within two to three hours; loss of judgment

Frontal headache within one to two hours

Dizziness, nausea, and convulsions within 45 min; insensible within 2 hours

Headache, increased heart rate, dizziness, and nausea within 20 min; death in less than 2 hours ppm - Parts Per Million - is used to describe concentrations of contaminants in air.

In the event of ALARM caused by a critical CO concentration level, keep calm and carry out the following actions in the priority order:

• Open all windows and doors to increase the rate of ventilation.

• Turn off the appliances and stop using them where possible.

• Evacuate the building leaving the windows and doors open. You may re-enter the property only when the alarm has stopped.

• Get immediate medical assistance for anyone suffering the effects of carbon monoxide poisoning (nausea, headache), and report that carbon monoxide inhalation is suspected. Contact the gas or other fuel supplier on their emergency phone number in order to identify and eliminate the source of carbon monoxide emissions.

EWF1-EWF1CO EN 9

• Do not use the appliance again until it has been verified and confirmed by a competent person according to national regulations.

There could be other sources of carbon monoxide emissions. For example, large amount of city gas, tobacco smoke or smoldering fire can cause CO concentration ALARM.

2.2 CO ALARM/RESTORE AND FAULT INDICATIONS

• Fresh air level - when CO concentration is 0-29ppm. This level causes no alarm when reached as well as it results in zone restore event when one of the critical levels has been reached and decreased to 0-29ppm afterwards. The zone restore event is indicated by SMS text message delivered to the listed user phone number and data message delivered to the monitoring station followed by silenced sirens. Also, data message notifying about CO gas fault is delivered to EL-

DES Cloud Services and added to the Event Log.

• CO critical level 1 – when CO concentration of 30-49ppm remains for more than 120 minutes.

Indicated by fault indication displayed by EKB2 LCD keypad (only for ESIM364) and a warning delivery to the listed user by SMS text message. This level causes no zone alarm when reached as well as it results in zone restore event in case the CO concentration of 300ppm or more (critical level 4) has been reached and decreased to 30-49ppm afterwards. Also, data messages notifying about CO critical level 1 and gas fault detection are delivered to ELDES Cloud Services and added to both Event Log and Fault Log respectively.

• CO critical level 2 – when CO concentration of 50-99ppm remains for more than 60 minutes.

Indicated by a 2-second beep every 5 seconds, LED indicator flash, fault indication displayed by EKB2 LCD keypad (only for ESIM364) and a warning delivered to the listed user by SMS text message. This level causes no zone alarm when reached. Also, data messages notifying about

CO critical level 2 and gas fault detection are delivered to ELDES Cloud Services and added to both Event Log and Fault Log respectively.

• CO critical level 3 – when CO concentration of 100-299ppm remains for more than 10 minutes.

Indicated by a 2-second beep every 5 seconds, LED indicator flash and fault indication displayed

10 EN EWF1-EWF1CO

by EKB2 LCD keypad (only for ESIM364) and a warning delivered to the listed user by SMS text message. This level causes no zone alarm when reached. Also, data messages notifying about

CO critical level 3 and gas fault detection are delivered to ELDES Cloud Services and added to both Event Log and Fault Log respectively.

• CO critical level 4 – when CO concentration of 300ppm and more is reached. This level will cause an alarm when reached resulting in the unit emitting a 2-second beep every 5 seconds and LED indicator flash. Meanwhile the system will notify the listed user by SMS text message and the monitoring station as well as all wired and wireless sirens will emit a pulsating sound based on the Fire-type zone operational description and activate the interconnection feature (by default - enabled; see

4.2. Interconnection). All wired and wireless sirens can be silenced by disarming the system. However, EWF1CO built-in siren will remain active until the TEST WEEK-

LY button has been pressed. Also, data messages notifying about CO critical level 4 and gas fault detection are delivered to ELDES Cloud Services and added to both Event Log and Fault Log respectively.

• CO unit fault – when CO sensor’s 7-year lifetime period has ended or in case of any technical issue that has occurred. Indicated by a fault indication displayed by EKB2 LCD keypad (only for

ESIM364) and notification delivery to the listed user via SMS text message and the monitoring station. Please contact your local suppli er for repair service.

2.3 CLEANING AND PRECAUTIONS DURING USE

Clean the detector at least once a month to remove dust, dirt, or debris. Using the soft brush or wand attachment of a vacuum cleaner, vacuum all sides and cover of the detector. Be sure all the vents are free of debris. If necessary, use a damp cloth to clean the detector cover.

Some household substances can affect the sensitivity of the detectors in a short or long term. Avoid the use of model paint, model glue or nail polish remover close to the detector. Do not use aerosol sprays, household cleaners, polishes or perfumes close to the device.

Do not attempt to remove the cover to clean inside the detector. This will void your warranty.

EWF1-EWF1CO EN 11

3. CONFIGURING AND PAIRING WITH THE SYSTEM

For more details on how to configure and pair the device with the system, please refer to ELDES Configuration Tool software’s HELP section or to

ELDES alarm system’s installation/user manual.

ELDES

Configuration Tool

If you are unable to pair the wireless device, please restore the parameters of the wireless device to default and try again (see

4.4 RESTORING THE DEFAULT PARAMETERS for more details).

4. MAINTENANCE

4.1 TESTING THE UNIT

• The TEST WEEKLY button verifies if EWF1/EWF1CO is operational. Firmly push the TEST

WEEKLY button and the detector will sound a loud beep. The alarm will stop sounding after releasing the TEST WEEKLY button. When testing EWF1/EWF1CO using ELDES Configuration

Tool software, the detector will provide short beeps.

• The CO self-test on EWF1CO will be carried out by pushing the TEST WEEKLY button at carbon monoxide concentration below 30ppm. The button release will be followed by a built-in siren sound after a 10-second period:

• Successful test - 5 beeps each lasting for 100 ms.

• Failed test - 1 beep lasting for 1 sec. Please contact your local suppli er for repair service.

• Stand at arm’s length from the detector when testing.

• Test the detectors weekly and upon returning from vacation or when no one has been in the household for several days.

• Test each detector to be sure it is installed correctly and operating properly.

• DO NOT use an open flame to test this detector. You may ignite and damage the detector or your home.

• If the detector does not sound, please check the battery and signal level using ELDES Configuration Tool software.

12 EN EWF1-EWF1CO

Test all detectors weekly to ensure proper operation.

CO self-test is possible only after more than 3 minutes of EWF1CO runtime.

4.2

INTERCONNECTION

The interconnection feature automatically links all wireless detectors that are paired with the alarm system. When any EWF1/EWF1CO detects smoke/CO, it will sound the built-in siren and send the signal to the alarm system resulting in an instant alarm followed by built-in siren sound caused by the rest of EWF1/EWF1CO devices. EWF1/EWF1CO device that detected smoke will auto-reset when the smoke clears, while the rest of EWF1/EWF1CO devices will continue to sound in accordance with the set time period (by default - 30 seconds) that can be managed by ELDES Configuration Tool software.

Interconnection will commence when CO critical level 4 has been reached (see

2.2. CO

Alarm/Restore and Fault Indications).

4.3 BATTERY REPLACEMENT

For more information on how to change the battery and perform a device test, see section HOW TO

INSTALL on page 6-7.

Only Primary 9V Lithium 1200mAh battery can be used. Install only new, high quality and unexpired batteries.

The battery must be removed if the device is not in use.

EWF1-EWF1CO EN 13

In order to avoid fire or explosion hazards, the system must be used only with approved battery. Special care must be taken when connecting positive and negative battery terminals.

Dispose old batteries only into special collection sites. Do not charge, disassemble, heat or incinerate old batteries.

The battery status can be monitored in real-time using ELDES Configuration Tool software.

The system sends an SMS message to the listed user phone number as soon as the battery level runs below 5%.

We strongly recommend using EVE CR9V-P or Energizer LA522 battery.

4.4 RESTORING THE DEFAULT PARAMETERS

1. Remove the battery from EWF1/EWF1CO.

2. Press and hold the RESET button.

3. Insert the battery back to EWF1/EWF1CO.

4. Hold the RESET button until you hear a short beep.

5. Release the RESET button.

5. EWF1/EWF1CO ZONE AND TAMPER

Upon successful device pairing process, the system adds wireless zone (-s) as follows:

• EWF1 - 1 Fire-type zone intended for smouldering fire/smoke detection.

• EWF1CO - 1 Fire-type and 1 CO-type zone intended for smouldering fire/smoke detection and carbon monoxide detection respectively.

In case of tamper violation, the alarm is caused regardless of system being armed or disarmed.

There are 2 ways to detect tamper violation on EWF1/EWF1CO:

14 EN EWF1-EWF1CO

• By tamper switch. EWF1/EWF1CO comes equipped with a built-in tamper switch intended for enclosure supervision: The tamper switch is located on the back of the PCB supervising the back side of the enclosure in case the device is illegally detached.

Once the enclosure of EWF1/EWF1CO is tampered with, the tamper switch will become triggered. This action will be followed by an alarm, resulting in sending an SMS text message and/ or phone call to the user. The SMS text message contains the violated tamper name. Also, this event is added to the Event Log, meanwhile data messages notifying about triggered tamper are delivered to the Monitoring Station and ELDES Cloud Services respectively.

• Wireless connection loss. The wireless connection loss between EWF1/EWF1CO and ELDES alarm system leads to alarm. The system identifies this event as a tamper violation and sends alarm by SMS text message and phone call to the user (-s) by default. The SMS text message contains the wireless device model, wireless ID code and tamper name. The user will also be notified by SMS text message as soon as the wireless signal is restored. Also, this event is added to the Event Log, meanwhile data messages notifying about wireless connection loss will be delivered to the Monitoring Station and ELDES Cloud Services respectively.

The tamper will not operate if the wireless zone (-s) is disabled.

6. TEMPERATURE SENSOR

The device comes equipped with a built-in temperature sensor allowing to monitor the temperature of the area surrounding EWF1/EWF1CO device. When using the with EPIR3 alarm system, you may set the MIN and MAX temperature thresholds ranging from +5°C to +45°C resulting in SMS text message delivery to the listed user phone number once exceeded. The accuracy of temperature measurement is +/-1°C. Also, this event is added to the Event Log, meanwhile data messages notifying about exceeded temperature threshold are delivered to the Monitoring Station and ELDES Cloud Services respectively.

EWF1-EWF1CO EN 15

7. TECHNICAL SPECIFICATIONS

EWF1 compatible with:

• ESIM264 v7.11.30 and up + EWT1 16.14 and up.

• ESIM364 v02.04.01 and up.

• EPIR2 v01.01.02 and up.

• EPIR3 all versions.

• PITBULL EPIR3 all versions.

EWF1CO compatible with:

• ESIM364 v02.11.00 and up.

• EPIR3 v01.07.00 and up.

• PITBULL EPIR3 V02.01.00 and up.

Main features

• Photoelectric sensor for slow smouldering fires

(EWF1) / Combined photoelectric and electrochemical sensor for slow smouldering fires and carbon monoxide (CO) detection (EWF1CO)

• TEST WEEKLY button

• Non-radioactive technology for environmental friendly

• High and stable sensitivity

• Quick fix mounting plate for easy installation

• LED operation indicator

• Built-in speaker for audio alarm indication

• Auto-reset when smoke clears

EWF1 is a wireless photoelectric-based smoke detector designed to detect smouldering fire before bursting into flame, while EWF1CO is a wireless electrochemical-based carbon monoxide (CO) detector combined with photoelectric-based smoke detector designed to detect smouldering fire. When the concentration of smoke/CO exceeds a given threshold, the system will cause alarm, resulting in built-in siren activation and SMS text message and phone call delivery (by default) to the listed user’s phone number. By default, when more than one EWF1/EWF1CO device is used, the system will automatically activate the interconnection fea ture. See

4.2. Interconnection.

ESIM264, EPIR2 and EPIR3 alarm systems support up to 16 EWF1 devices, while ESIM364 - up to 32

EWF1 devices. Up to 16 EWF1CO can be connected to EPIR3 alarm system, while ESIM364 supports up to 32 EWF1CO devices. The maximum wireless connection range is 150m (492.13ft) (in open areas).

16 EN EWF1-EWF1CO

For complete information on device operation with ELDES alarm system, please refer to EL-

DES alarm system installation manual located at www.eldes.lt/download.

ELECTRICAL & MECHANICAL CHARACTERISTICS

Battery .........................................................................Primary 9V Lithium 1604LC (ANSI/NEDA)

Number of batteries ................................................1

Battery operation time ...........................................18 months*

Wireless band ............................................................ISM868/ISM915

Wireless communication range ............................Up to 30m (98.43ft) in premises; up to 150m (492.13ft) in open areas

Smoke detection type .............................................Photoelectric chamber

Smoke sensitivity ....................................................3.0-6.0 % O bs/m

Carbon monoxide detection type .........................Electrochemical

Carbon monoxide detection range .......................0-400 ppm

Alarm sound level ...................................................85dB at 3m (85dB at 9.84ft)

EWF1 lifetime ............................................................10 years

EWF1CO lifetime .......................................................7 years

Range of operating temperatures . .......................+5... +45°C (41... 113°F)

Humidity ....................................................................0-90% RH @ 0... +40°C (0-90% RH @ +32... +104°F)

(non-condensing)

Dimensions ...............................................................110mm (4.33in) Ø

* The specified operation time applies in case of no alarms and when having the device tested once a week. The operation time might vary in different conditions.

Technical support

If you experience difficulty during the installation or subsequent use of a ELDES UAB system, you may contact ELDES UAB distributor or dealer in your country/region.

Warranty procedures

To obtain warranty service, you may return a defective system to your original point of purchase, or the authorized ELDES UAB dealer or distributor from whom you purchased the ELDES product.

EWF1-EWF1CO EN 17

Made in the European Union www.eldes.lt

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement