product catalog - national petroleum equipment

product catalog - national petroleum equipment
NS
T
TIO
Y
O
R
US
SO
L
U
U C N T
A
PRODUCT CATALOG
Table of Contents
Fuel Management Systems
Franklin Fueling Systems manufactures and markets a complete line of fuel management systems
globally under the INCON product brand. Automatic tank gauges, electronic line leak detection,
magnetostrictive probes and remote monitoring software are just some of the products available.
All are designed and manufactured using state-of-the-art technology to meet all of our customers’
fuel management and leak detection compliance needs.
3
TS-5 Fuel Management System
3
TS-550 and TS-5000 Fuel Management Systems 5
Fuel Management System Console Accessories 7
Environmental & Tank Monitoring
Colibri Tank Monitor
TS-EMS Environmental Monitoring System
In-Station Diagnostics
Tank Sentinel® Consoles
TS-1001 Full Feature Compliance Console
TS-1001/G Fixed Feature Generator Tank
Monitoring Console
TS-504 and TS-508 Fixed Feature Inventory
Control Consoles
TS-750 Fixed Feature Tank Monitoring and
Compliance Kits
9
9
11
13
14
14
16
17
19
Tank Sentinel® Console Accessories
21
S940 Sensor Alarm Console
22
Electronic Line Leak Detectors
23
TS-L300 AutoLearn™
Line Sentinel™
23
25
Probes and Sensors
27
Leak Detection and Inventory Control Probes
Moorman Level Gauge Kit
Float Kits
Density Measurement Float Kit
Probe Installation Kits
TSP-HIS Hydrostatic Interstitial
Brite™ Sensor
TSP-DIS Discriminating Interstitial
Brite™ Sensor
TSP-EIS Electro-Optic Interstitial Sensor
TSP-ULS Liquid Sensor
TSP-UHS Universal Hydrostatic Sensor
TSP-DMS Discriminating
Magnetostrictive Sensor
TSP-DDS Discriminating Dispenser
Sump Brite™ Sensor
TSP-DTS Discriminating Turbine Sump
Brite™ Sensor
TSP-DVS Discriminating Vapor Brite™ Sensor
TSP-MWS Monitoring Well Brite™ Sensor
TSP-HLS Level Sensor
Sensor Installation Kits
Sensor Installation Accessories
33
34
35
36
36
37
38
38
39
39
40
41
43
Continued on next page...
Fuel Management Systems
Fuel Management System Consoles
27
29
30
31
32
1
Table of Contents
External Console Hardware
TS-RA1 Remote Audible and Visible
Alarm Unit
TS-RA2 Remote Audible and Visible
Alarm Unit
TS-RK Remote Alarm Acknowledge Unit
TS-DIM Dispenser Interface Module
TS-TPI Turbine Pump Interface
TS-ROM2 BriteBox™ Relay Output Module
TS-SEM BriteBox™ Sensor Expansion Module
TS-M Modem
TS-EPS Ethernet Port Server
External Console Hardware Accessories
Software
44
Sump Test System Kit
44
45
46
47
49
50
51
52
53
53
54
System Sentinel™ Remote Fuel
Management Software
54
System Sentinel AnyWare™ Internet Enabled
Fuel Management Software
56
Get Connected AnyWare™ Remote
Polling Service
57
Fuel Management Systems
2
Accessories
Spare Parts
TS-5, TS-550, TS-5000 and TS-EMS Consoles
TS-504 and TS-750 Consoles
TS-508 Console
TS-1001 Console
TS-2001 Console
TS-LLD
TS-LS300
TS-LS500
TS-STS Sump Test Kit
Accessories
60
60
62
62
62
62
63
63
63
64
64
64
64
Fuel Management System Consoles
Advantages
• Monitors up to 12 tanks.
• Continuous inventory monitoring
and tank testing through proven
magnetostrictive probe technology.
TS-5 Fuel Management System
The TS-5 fuel management system provides inventory and leak detection for up to
12 storage tanks.
• Highest rated continuous
24 hour leak detection (SCALD)
in the industry.
• Density measurement and
alarm capabilities.
• Low cost, compact console.
• Standard communication ports
including Ethernet, two RS-232
and USB.
• Internal fax and data modem options.
• Generates inventory, compliance and
fuel management reports.
Specifications
Applications
The fuel management system has been
designed to monitor tank tightness and
gather inventory information.
• Third party approved volumetric leak
detection (Pd = 99.9% at 0.2 gph).
• Can provide dispenser information
and automate reconciliation when used
in conjunction with the dispenser
interface module.
• Provides accurate inventory information,
including reports that can be used to better
schedule deliveries.
• Multipurpose relays can be used for
outputs to overfill alarms and external
audible and visual indicators.
Fuel Management Systems
• Number of tanks monitored: 12.
• Input channels: 2.
• Output only channels: 2.
• Display type: touch screen LCD.
• Applicable liquids: petroleum, chemicals and
hazardous waste.
• Level units: inches, centimeters and
millimeters.
• Volume units: gallons or liters.
• Display size: 320 × 240 pixels.
• Power requirements: 110 to 220 VAC,
+15%, -10%, 150 Watt maximum,
1.5 Amps.
• Operating temperature: 32° to 104 °F
(0° to 40 °C).
• Storage temperature: -4° to 140 °F
(-20° to 60 °C).
• Intrinsic safety rating:
US - Class I, Div. I, Group D.
Europe - Group IIA, Zone 0.
• LCD backlight contains mercury, dispose
of properly.
Capabilities
The fuel management system is built on an
established open-system software platform.
• Standard Ethernet connection allows easy
integration to existing wide area networks.
• XML-based software allows remote access
to data without additional software.
• Graphical touch screen LCD allows text to
be displayed in native language.
• E-mail notification gives station owners
real-time status information.
• Monitor back-up generators for fuel
inventory control, run status reports, and
continuous leak detection.
3
Fuel Management System Consoles
Model
Description
T5
TS-5 console without display
T5D
TS-5 console with LCD display
Note: Includes one TS-PRB 12 input probe module.
TS-5 Fuel Management
System Console
Ordering Guide
TS-5 Console Hardware and Software Options
Console model, software and
hardware options can be listed
separately or combined when
ordering. Systems shipped from the
factory will list the combined part
number. Complete console part
numbers have a specific order and are
created using the following guidelines:
The TS-5 console comes standard with the ability to perform in-tank static leak detection.
The following software and hardware options can be added to customize your consoles. The
internal hardware options will be factory installed when ordered with the console.
Internal Hardware Options
Part Number
TS-DIMIB5
TS-LON5
TS-MDMIB
Description
(I) Internal dispenser interface module, dispenser interface cable must be ordered
separately
(E) EcheLON communication module, IFSF protocol capability
(M) Internal modem, includes fax and data software capability
Note: Only one TS-DIMIB or TS-LON module can be installed per console.
Internal Software Options
Part Number
TS-TT
TS-TRAC
Description
(T) Statistical Continuous Automatic Leak Detection, 24 hour continuous tank
testing software
(R) Tank inventory reconciliation and auto calibration
T5 DM X / TR
T5 = Model
T5 = TS-5, 110 or 200 VAC.
DM X = Hardware Options
D = Display, standard in the TS-5.
M = Internal modem.
X = I for dispenser interface module
or E for a LON module.
TR = Software Options
T = SCALD 24-hour tank testing.
R = Reconciliation.
Fuel Management Systems
4
Fuel Management System Consoles
Advantages
• Monitors up to 72 tanks.
• Continuous inventory monitoring
and tank testing through proven
magnetostrictive probe technology.
TS-550 and TS-5000
Fuel Management Systems
The TS-550 and TS-5000 fuel management systems’ modular design provides compliance and
fuel management capability in a single enclosure.
• Highest rated continuous
24 hour leak detection (SCALD)
in the industry.
• Density measurement and
alarm capabilities.
• Patented AutoLearn™ electronic line
leak detection capability.
• Standard communication ports
including one Ethernet and USB,
two RS-232.
• Internal fax and data modem options.
• Can handle 72 dispenser hook
inputs, eliminating need for an
external box.
• Approved by the California Air
Resources Board EO VR-202.
Specifications
• Number of tanks monitored: 72.
• Input channels: 2.
• Output only channels: 2.
• Display type: touch screen LCD.
• Applicable liquids: petroleum, chemicals and
hazardous waste.
• Level units: inches, centimeters
and millimeters.
• Volume units: gallons or liters.
• Display size: 320 × 240 pixels.
• Power requirements: 110 to 220 VAC,
+15%, -10%, 150 Watt maximum,
1.5 Amps.
• Operating temperature: 32° to 104 °F
(0° to 40 °C).
• Storage temperature: -4° to 140 °F
(-20° to 60 °C).
• Intrinsic safety rating:
US - Class I, Div. I, Group D.
Europe - Group IIA, Zone 0.
• LCD backlight contains mercury, dispose
of properly.
Applications
The flexible architecture of the TS-550 and
TS-5000 allows multiple applications to run
concurrently, satisfying current business and
regulatory requirements.
• Fuel management system applications
provide accurate inventory information,
third party-approved tank and line leak
detection, automated inventory
reconciliation and submersible
pump monitoring.
• The vapor recovery monitoring application
gauges the effectiveness of a station’s vapor
recovery equipment through continuous
monitoring of gasoline vapors during
fueling operations.
• Secondary containment monitoring
application continuously monitors the
interstitial spaces of double wall tanks, lines
and sumps, and notifies station owners
when a release of product into the
environment has occurred.
Capabilities
The TS-550 and TS-5000 are built on an
established open-system software platform.
• Standard Ethernet connection allows easy
integration to existing wide area networks.
• XML-based software allows remote access
to data without software.
• Graphical touch screen LCD allows text to
be displayed in native language.
• Generic interface modules give
flexibility in configuring station
monitoring requirements.
• E-mail notification gives station owners
real-time status information.
• Multiple printing options give flexibility in
style and format of reports.
• Monitor back-up generators for fuel
inventory control, run status reports, and
continuous leak detection.
Fuel Management Systems
• Interstitial and piping sump leak
sensing for up to 72 sensors.
5
Fuel Management System Consoles
TS-550 110 and 220 VAC Models
Model
T550
T550D
T550DP
Description
TS-550 base console without display and printer
TS-550 base console with display and without printer
TS-550 base console with display and printer
TS-5000 110 and 220 VAC Models
Model
T5000
T5000D
T5000DP
Description
TS-5000 base console without display and printer
TS-5000 base console with display and without printer
TS-5000 base console with display and printer
Expansion Console
Model
TS-EXPC
Description
Secondary console to add eleven additional plug-in modules to the primary TS550/5000 console, comes without a display or printer
TS-550 and TS-5000 Console Hardware
and Software Options
TS-550 and TS-5000 consoles come standard with the ability to perform in-tank static leak
detection. The following software and hardware options can be added to customize your
console. The internal hardware options will be factory installed when ordered with the console.
Internal Hardware Options
Part Number
Description
(I) Internal dispenser interface module, dispenser interface cable must be ordered
TS-DIMIB
separately
TS-LON
(E) EcheLON communication module, IFSF protocol capability
TS-MDMIB
(M) Internal modem, includes fax and data software capability
Note: Only one TS-DIM or TS-LON module can be installed per console.
Internal Software Options
Part Number
TS-TT
TS-TRAC
TS-ELLD
TS-VRM
TS-SCM
Fuel Management Systems
6
Description
(T) Statistical Continuous Automatic Leak Detection, 24 hour continuous tank
testing software
(R) Tank inventory reconciliation and auto calibration
(L) Electronic line leak detection
(V) Vapor recovery monitoring, ISD
(S) Secondary containment monitoring
TS-550 and TS-5000
Fuel Management
System Console
Ordering Guide
Console model, software and
hardware options can be listed
separately or combined when
ordering. Systems shipped from the
factory will list the combined part
number. Complete console part
numbers have a specific order and are
created using the following guidelines:
TX DPM Y / TRLVS
TX = Model
T550 = TS-550, 110 or 220 VAC.
T5000 = TS-5000, 110 or 220 VAC.
DPM Y = Hardware Options
D = Display.
P = Printer.
M = Internal modem.
Y = I for dispenser interface module
or E for a LON module.
TRLVS = Software Options
T = SCALD 24-hour tank testing.
R = Reconciliation.
L = Line leak detection.
V = Vapor recovery monitoring.
S = Secondary containment monitoring.
Fuel Management System Consoles
Fuel Management System Console Accessories
TS-550 and TS-5000 Fuel Management System Console Interface Modules
TS-550 and TS-5000 consoles come standard with a power supply module and a controller module. Additional
interface modules can be installed. Interface modules ordered with a console will be installed at the factory. The
following guidelines must be followed:
• TS-550: Six total modules can be installed with a maximum of four intrinsically safe modules and a maximum of three
of any one kind of module.
• TS-5000: Eleven total modules can be installed with a maximum of nine intrinsically safe modules and a maximum of
three of any one kind of module.
Intrinsically Safe Modules
Part Number
TS-PRB
TS-2WSNS
TS-3WSNS
TS-4201B
Description
12 input probe module, LL2 Series mag probes,VFM flow meters and DMS Mag sensors
12 input 2-wire sensor module, TSP-ULS and TSP-HLS sensors
8 input 3-wire sensor module, TSP-EIS, TSP-DIS, TSP-DDS, TSP-DTS, TSP-HIS, TSP-MWS and TSP-DVS sensors
8 input 4-20 mA module, LSU500 transducers and VPS and SCCM pressure sensors
Non-Intrinsically Safe Modules
Part Number
TS-ACI
TS-RLY
TS-10ARLY
TS-IO
TS-420EXP
Description
12 input AC input module, dispenser hook inputs
8 output relay module, SCCM solenoid and STP control
6 output 10 Amp relay output module, dispenser power
Input output module, 4 output 4-20 mA, 8 input 3-240 VAC/DC
8 input 4-20 mA module, LSU500E transducers and external devices
Note: TS-RLY Module is not required for STP control when utilizing turbine pump interface (TPI) communications.
The TS-420EXP module requires Controller Module software version 9.5 or greater
TS-LS500 AutoLearn™
Pressurized line leak detection provides automatic 3.0 gph hourly, 0.2 gph monthly and 0.1 gph annual precision
line leak detection for TS-550 and TS-5000 consoles. Available in intrinsically safe and explosion proof models. Use
explosion proof when low voltage conduit is not available. The TS-420IB or TS-420EXP, TS-ACI and TS-RLY module
and TS-ELLD software option must be ordered and installed in the fuel management system console.
Intrinsically Safe
For new installations where separate low voltage conduits can be used. Use TS-420IB module.
Model
TS-LS500/2
TS-LS500/3
TS-LS500/4
Description
2-line transducer kit
3-line transducer kit
4-line transducer kit
Note: Using turbine pump interface (TPI) communications eliminates the need for a TS-RLY module;
FFS intelligent controllers required.
Model
TS-LS500E/2
TS-LS500E/3
TS-LS500E/4
Fuel Management Systems
Explosion Proof
For retrofit installations where only a high voltage conduit can be used. Use TS-420EXP module.
Description
2-line transducer kit, explosion proof
3-line transducer kit, explosion proof
4-line transducer kit, explosion proof
Note: Using turbine pump interface (TPI) communications eliminates the need for a TS-RLY module;
FFS intelligent controllers required.
Alternative Fuels Accessories
Model
TS-AFALNIP
Description
Leak generator needle valve kit required for E85 installations
Dispenser Interface Module Cables
Part Number
TSP-WDCBL
TSP-TDCBL
TSP-GDCBL
TSP-GSDCBL
TSP-BDBCL
Description
Wayne cable
Tokheim cable
Gilbarco cable
Gilbarco G-Site cable
Bennett 515 only cable
7
Fuel Management System Consoles
Paper Supplies
Part Number
TS-TP5000
TS-550 and TS-5000 impact printer paper
TS-TP5000C
12 rolls of impact printer paper
TS-INKRB
TS-550 and TS-5000 ink ribbon
Description
Secondary Containment Monitoring
The secondary containment monitoring system is designed to detect leaks in double-wall tanks, sumps and piping. TS-420IB,
TS-RLY and TS-ACI modules and the TS-SCM software option must be ordered and installed in the tank gauge console.
Sensor Modules
Part Number
TS-SCCM/1
TS-SCCM/2
TS-SCMCAL
VS-SCCM/1
VS-SCCM/2
Description
Single channel secondary containment control module
Dual channel secondary containment control module
Leak generator kit, one per station
220 VAC single channel secondary containment control module
220 VAC dual channel secondary containment control module
Install Kit
Part Number
TSP-SCLSI
TSP-SCTK2
TSP-SCTK2B
TSP-SCTK4
TSP-SCTK4B
Description
Product, vapor line and sump containment install kit
Tank containment install kit for 2" risers, in-tank hose sold separately
Tank containment install kit for 2” risers with BSP threads, in-tank hose sold separately
Tank containment install kit for 4" risers, in-tank hose sold separately
Tank containment install kit for 4” risers with BSP threads, in-tank hose sold separately
Accessories
Part Number
TSP-SCBRB
TSP-SCBRBT
TSP-SCCLP
TSP-SCTB25
TSP-SCTB50
TSP-SCTB100
TSP-SCVLV
Description
Five 1/4" NPT barbed fittings
1/4" NPT barbed T-fitting
Five hose clamps
25' hose
50' hose
100' hose
Five Schreader valves
Upgrading Installed Fuel Management System Consoles
Fuel Management Systems
Two types of upgrades can be done on a fuel management system console: feature upgrades and software upgrades.
The latest software versions are included with all feature upgrades. Most feature upgrades require ordering a software
option, hardware options and interface modules. Some modules may already be installed.
Feature Upgrade
Upgrade
Software
Internal modem
24 hour tank testing TS-TT SCALD tank testing
Line leak
Tank inventory
reconciliation
Secondary
containment
monitoring
Hardware
TS-MDMIB internal modem
TS-ELLD electronic line
leak detection
Appropriate TS-LS500/N
transducer kit
TS-TRAC tank inventory
reconciliation and auto calibration
TS-DIMIB module
Appropriate DIM interface cables
Interface Module
TS-RLY module, not needed with TPI
TS-420IB module
TS-ACI module
TS-ACI module
TS-RLY module
TS-420IB module
TS-ACI module (not needed w/ VRM 1.2)
TS-VFM flow meters
Vapor recovery
TS-VRM vapor
TS-RLY or TS-10ARLY module
TS-VPS pressure sensor
monitoring (ISD)
recovery monitoring
TS-PRB probe module
TS-DIMIB dispenser interface
TS-420IB module
Note: When placing an order for a feature upgrade, the serial number of the console to be upgraded must be supplied.
TS-SCM secondary
containment monitoring
Appropriate TS-SCCM modules,
installation kits and accessories
Software Version Upgrade Only
8
Part Number
Description
TSA-UPGMS
Software version upgrade shipped on a USB memory stick
Environmental & Tank Monitoring
Advantages
• Monitors fuel levels and density
measurements in up to six tanks.
• Static and continuous tank leak
detection capabilities.
• Standard communication ports.
• External USB printer support.
• Web interface for remote access.
• Programmable email notification of
alarms and events.
Colibri Tank Monitor
Colibri is the ideal solution for the fueling station owner who requires basic, straightforward
functionality in a fuel inventory monitoring system. The Colibri system monitors fuel density and
inventory levels in up to six tanks and provides accurate, reliable information without manually
taking tank readings. Additional features communicate the status of tank contents, including
volume, temperature, mass, water level and continuous tank leak detection. The Web interface
feature allows authorized users access to tank information from any computer connected
to the internet or wide area network, as well as custom alerts which can be sent to email or
mobile devices. The Colibri tank monitor is the highest quality, best value solution available for
any fueling station that requires essential tank monitoring capabilities.
• Compact size provides installation
location flexibility.
• Autocalibration can recreate missing
or inaccurate tank strapping charts.
Specifications
Standard Capabilities
• Number of tanks monitored: 6
• Output channels: 2
• Display type: color LCD touch screen
• Internal audible alarm
• Alarm, warning and power LEDs
• Applicable liquids: petroleum, chemicals and
hazardous waste
• Level units: centimeters, millimeters
and inches
• Volume units: liters or gallons
(mass with density option)
• Display size: 142 mm (5.6 in)
• Dimensions: 185 mm x 303 mm x 57 mm
(7.27 in x 11.92 in x 2.24 in)
• Power requirements: 94 to 264 VAC,
50/60 Hz 1.0 Amps
• Operating temperature: 0 to 40 °C
(32 to 104 °F)
• Humidity: 0% to 95% non-condensing
• Intrinsically safe rating: US – Class I, Div. I,
Group D Europe – Group IIA, Zone 0
• Compatible with FFS inventory and leak
detection LL2 probes
• Inventory and delivery management
• Static tank leak detection
• High, low and water alarm set points
• Available with or without display
• Web interface and email notifications
Fuel Management Systems
Optional Capabilities
• SCALD 24 hour tank leak detection
• Inventory reconciliation /
Tank autocalibration
• Density and mass measurement
Approvals
• UL, cUL, ATEX, IECEx
• Third party certification of leak
detection capabilities
9
Environmental & Tank Monitoring
Ordering Guide
303 mm
(11.92")
LCD Display
(Optional)
185 mm
(7.27")
Intrinsically Safe
Conduit Entry
(alternate entry
on console top)
Non-Intrinsically Safe
Conduit Entry
(alternate entry on
console top)
RS232 Serial Port
Ethernet Port
2 USB Ports
Alarm Speaker
Colibri Consoles
Model
CL6
CL6D
Description
Six channel Colibri console without display
Six channel Colibri console with display
Internal Software Options
Model
TS-TT
TS-TRAC
Description
(T) Statistical Continuous Automatic Leak Detection (SCALD),
24 hour continuous tank testing software
(R) Tank inventory reconciliation and autocalibration software
Fuel Management Systems
Leak Detection and Inventory Control Probes
Colibri is compatible with all TSP-LL2-xxx leak detection and TSP-LL2-xxx-I inventory probes,
which should be ordered separately along with the appropriate float kit. Inventory probes do
not require a special installation kit and may be installed on the bottom of a tank using a cap
with the appropriate cable gland. Leak detection probes and tanks utilizing optional density
floats must be installed using the appropriate Franklin Fueling Systems installation kit.
10
CL6 D / TR
CL6 = Colibri Model
D = Display Option
TR = Software Options
T = SCALD 24 hour tank testing
R = Reconciliation/autocalibration
Alarm LED
Warning LED
Power LED
57 mm
(2.24")
Console model and software can be
listed separately or combined when
ordering. Systems shipped from the
factory will list the combined part
number. Complete console part
numbers have a specific order and are
created using the following guidelines:
Environmental & Tank Monitoring
Advantages
• Standalone ISD system.
• Approved by the California Air
Resources Board EO VR-202.
• Includes TS-VRM vapor recovery
monitoring software and optional
secondary containment monitoring.
TS-EMS Environmental
Monitoring System
The TS-EMS environmental monitoring system can perform in-station diagnostic vapor
recovery monitoring (VRM) and secondary containment monitoring (SCM) and interface to an
existing tank gauge.
• Dispenser-based disabling prevents
the entire site from shutting down in
the event of an EVR failure.
• Wired-less Flow Meter and Pressure
Sensor interface option.
• Ethernet-ready, web-based remote
access provides the user with
remote access to VRM status
information, reports and alarm
information using any web browser.
• Create custom rules to send e-mails
and text messages on alarms and
events directly from the console to
service and compliance personnel.
• User-friendly touch screen interface
with icon-based navigation.
Specifications
• Number of dispensers monitored: 16.
• Input channels: 2.
• Output only channels: 2.
• Display type: touch screen LCD.
• Volume units: gallons or liters.
• Display size: 320 × 240 pixels.
• Power requirements: 110 to 220 VAC,
+15%, -10%, 150 Watt maximum,
1½ Amps.
• Operating temperature: 32° to 104 °F
(0° to 40 °C).
• Storage temperature: -4° to 140 °F
(-20° to 60 °C).
• Intrinsic safety rating:
US - Class I, Div. I, Group D.
Europe - Group IIA, Zone 0.
• LCD backlight contains mercury, dispose
of properly.
Applications
The flexible architecture of the TS-EMS
allows multiple applications to run
concurrently, satisfying multiple
monitoring needs.
• The vapor recovery monitoring
application gauges the effectiveness of a
station’s vapor recovery equipment
through continuous monitoring of gasoline
vapors during fueling operations.
• Secondary containment monitoring
application continuously monitors the
interstitial spaces of double wall tanks, lines
and sumps, and notifies station owners
when a release of product into the
environment has occurred.
Capabilities
The TS-EMS is built on an established
open-system software platform.
• Standard Ethernet connection allows easy
integration to existing wide area networks.
• XML-based software allows remote access
to data without additional software.
• Graphical touch screen LCD allows text to
be displayed in native language.
• Generic interface modules give
flexibility in configuring station
monitoring requirements.
• E-mail notification gives station owners
real-time status information.
• Multiple printing options give flexibility in
style and format of reports.
Fuel Management Systems
• Scalable open architecture for easy
and cost-saving future upgrades.
11
Environmental & Tank Monitoring
Model
TEMSDPI/V
TEMS2DPI/V
TEMS3DPI/V
TEMSDPI/VS
TEMS2DPI/VS
Description
TS-EMS console with display, printer, DIM,VRM software and one TS-PRB, TS420IB and TS-10ARLY
TS-EMS console with display, printer, DIM,VRM software, one
TS-PRB and TS-420IB, and two TS10ARLY
TS-DTU ready TS-EMS console with display, printer, DIM,VRM software, and
one TS-10ARLY module
TS-EMS console with display, printer, DIM, VRM and SCM software, and one
TS-PRB, TS-420IB and TS-10ARLY
TS-EMS console with display, printer, DIM and SCM software, one TS-PRB and
TS-420IB, and two TS-10ARLY
Notes: 1. Appropriate DIM cable must be ordered separately.
2. TEMS and TEMS3 systems can support up to six dispensers. TEMS2 systems can support
up to twelve dispensers. All models can be expanded to support up to 16 dispensers with
additional modules.
3. The appropriate number of TS-VFM vapor flow meters and one TS-VPS vapor pressure sensor
must be ordered separately to perform vapor recovery monitoring.
4. TS-ACI modules and hook signal wiring is no longer required for TS-EMS installs.
TS-EMS Console Hardware and Software Options
TS-EMS consoles come standard with the ability to perform vapor recovery monitoring.
The following software and hardware options can be added to customize your console. The
internal hardware options will be factory installed when ordered with the console.
Internal Hardware Options
Part Number
TS-MDMIB
Description
(M) Internal modem, includes fax and data software capability
Internal Software Options
Part Number
TS-SCM
Description
(S) Secondary containment monitoring
TS-EMS Fuel Management System
Console Interface Modules
TS-EMS consoles come standard with a power supply module, a controller module and a
model dependent set of interface modules that can support up to 6 or 12 dispensers. In some
situations non-standard module configurations may be required. Additional modules will be
shipped separately from the EMS console. Six total modules can be installed with a maximum
of four intrinsically safe modules and a maximum of three of any one kind of module.
Intrinsically Safe Modules
Part Number
TS-PRB
TS-4201B
Description
12 input probe module,VFM flow meters
8 input 4-20 mA module,VPS and SCCM pressure sensors
Fuel Management Systems
Non-Intrinsically Safe Modules
Part Number
TS-RLY
TS-10ARLY
Description
8 output relay module, low power dispensers and SCCM solenoids
6 output 10 Amp relay output module, high power dispensers and
SCCM solenoids
External Modules
Part Number
TS-DTU/P
Description
Data transfer unit for wired-less VFM and VPS communications
Note: Order one TS-DTU/P and one TS-DRK/x install kit per dispenser. Order one additional TS-DTU/P
for the console.
Dispenser Interface Module Cables
Part Number
TSP-WDCBL
TSP-TDCBL
TSP-GDCBL
TSP-GSDCBL
TSP-BDCBL
12
Description
Wayne cable
Tokheim cable
Gilbarco cable
Gilbarco G-Site cable
Bennett 512 cable
TS-EMS Enivornmental
Monitoring System
Ordering Guide
The TS-EMS environmental monitoring
system comes standard with display,
printer and dispenser interface
module. An internal TS-MDMIB
modem can be added as a hardware
option. Order the TEMSDPI/VS if the
secondary containment monitoring
software option is required.
Environmental & Tank Monitoring
Advantages
• Dispenser-based disabling prevents
the entire site from shutting down in
the event of an EVR failure.
• Wiredless Flow Meter and Pressure
Sensor interface option when
conduit is not present.
• Ethernet-ready, web-based remote
access provides the user with
remote access to VRM status
information, reports and alarm
information using any web browser.
In-Station Diagnostics (ISD)
The INCON vapor recovery monitoring (VRM) option meets or exceeds all ISD
requirements for ensuring that all components of the vapor recovery system are functioning
normally. Recorded sales transactions are compared to data obtained from a TS-VFM vapor
flow meter installed in each dispenser to verify that equivalent vapors are recovered from the
vehicle when fuel is dispensed. The pressure of the vapor containment space is constantly
monitored by the TS-VPS vapor pressure sensor and tested for over pressure and leakage
conditions. Local and remote notification options alert the user of abnormalities and
dispenser-based disabling keeps the rest of the site up and running when a single dispenser
EVR system has a problem. The Wiredless option, featuring the TS-DTU, prevents the need to
break concrete to install new conduit or even pull wires and reduces the cost of the console.
• Create custom rules to send e-mails
and text messages on alarms and
events directly from the console to
service and compliance personnel.
• User-friendly touch screen interface
with icon-based navigation.
• Scalable open architecture for easy
and cost-saving future upgrades.
TS-DTU
TS-5000
TS-550
TS-EMS
• Uses dispenser power wires to
transmit data.
• Multi-industry proven power line
communications technology.
• Save weeks of installation time.
• Save thousands of dollars in costly
conduit installation and avoid
damaged and blocked conduit.
Vapor Flow Meter
• No disruption of forecourt by having
to break concrete.
• No need to pull wires.
• Will not interfere with
dispenser operation.
• UL approved for installation in most
common dispenser models.
• Works even if some dispensers are
on different phases.
Model
TS-VFM
TS-VPS
TS-VRM
TS-DTU/P
TS-DRK/A
TS-DRK/E
TS-DRK/T
TS-DRK/W
Vapor Pressure Sensor
Data Transfer Unit
Description
Vapor flow meter, one per dispenser
Vapor pressure sensor, one per site
Vapor recovery monitoring software
Data transfer unit for wiredless VFM and VPS communications
Gilbarco Advantage dispenser retrofit install kit
Gilbarco Encore dispenser retrofit install kit
Tokheim dispenser retrofit install kit
Wayne dispenser retrofit install kit
Fuel Management Systems
• Save on the cost of the console due
to a reduction in modules needed.
Notes: 1. Approved by California Air Resources Board EO VR-202.
2. Minimum module requirements include one TS-PRB, TS-420IB, TS-RLY or TS-10ARLY.
3. TS-VRM software is included in the TS-EMS console.
4. Order one TS-DTU/P and one TS-DRK/x install kit per dispenser. Order one additional
TS-DTU/P for the console. Controller Module software 9.5 or greater required.
5. Consoles using the wiredless option do not require the TS-PRB or TS-420IB modules for
communication with the TS-VFM and TS-VPS
6. TS-ACI modules and hook signal wiring is no longer required for ISD applications.
13
Tank Sentinel® Consoles
TS-1001 Full Feature
Compliance Consoles
The TS-1001 consoles feature business management and environmental compliance capabilities.
They offer inventory, leak detection, reporting and alarm notification.
Applications
The automatic tank gauge has been designed
to monitor tank tightness, gather inventory
information and assist with multiple
environmental compliance issues.
• Third party approved volumetric leak
detection (Pd = 99.9% at 0.2 gph).
• Can provide dispenser information
and automate reconciliation when used
in conjunction with the dispenser
interface module.
• Provides accurate inventory information
including reports that can be used to better
schedule deliveries.
• Multipurpose relays can be used for
outputs to overfill alarms and external
audible and visual indicators.
Specifications
Fuel Management Systems
• Number of tanks monitored: 4.
• Input channels: 2 (10*).
• Output only channels: 2 (10*).
• Sensor inputs: 12 (28*).
• Dimensions: 11" × 12" × 4".
• Display type: alphanumeric LCD.
• Applicable liquids: petroleum, chemicals
and hazardous waste.
• Level units: inches or millimeters.
• Volume units: gallons or liters.
• Temperature units: degrees Fahrenheit
or Celsius.
• Display size: 2 lines of 40 characters.
• Power requirements:
115 VAC - +15%, -10%, 100 Watts
maximum, 1 Amp maximum.
230 VAC - +15%, -10%, 100 Watts
maximum, 0.5 Amp maximum.
• Operating temperature: 32° to 122 °F
(0° to 50 °C).
• Storage temperature: -4° to 140 °F
(-20° to 60 °C).
• Intrinsic safety rating:
US - Class I, Div. I, Group D.
• Number of LLDs supported: 4.
• Printer type: 24 column thermal.
14
Capabilities
The TS-1001 has programmable settings and
is capable of monitoring up to four tanks.
• Offers a wide range of advanced
communication options.
• Expanded, backlit LCD display with two
lines of 40 columns.
• Supports multiple languages.
• Supports English and metric units.
• Generates numerous system warnings and
tank alarms to quickly notify the user of any
potential problems.
• Supports important generator and fuel
management features.
*
Maximum number when including
additional options.
Advantages
• Monitors up to 4 tanks.
• Designed on an open architecture
platform that is easily expandable for
additional capabilities.
• Low cost, compact console handles
a wide range of applications and
is easily programmed through
multipurpose function keys to meet
site-specific criteria.
• Internal high-speed fax/data modem
capability allows remote access
from System Sentinel™ and System
Sentinel AnyWare™.
• Executes automatic system check
and notifies user if the unit is not
functioning properly and performs
continuous leak testing, no station
down time required.
Tank Sentinel® Consoles
TS-1001 Console
Ordering Guide
Console model, software and
hardware options can be listed
separately or combined when
ordering. Systems shipped from the
factory will list the combined part
number. Complete console part
numbers have a specific order and are
created using the following guidelines:
XX PM / A B C CLR
TS-1001, 110 VAC Models
Model
T1P/0
T1P/2
T1P/4
Description
Leak monitor with 12 sensor inputs and printer
ATG, up to 2 tanks with 12 sensor inputs and printer
ATG, up to 4 tanks with 12 sensor inputs and printer
TS-1001, 220 VAC Models
Model
V1P/0C
V1P/2C
V1P/4C
Description
Leak monitor with 12 sensor inputs and printer
ATG, up to 2 tanks with 12 sensor inputs and printer
ATG, up to 4 tanks with 12 sensor inputs and printer
XX = Model
T1 = TS-1001, 120 VAC.
V1 = TS-1001, 220 VAC.
PM = Hardware Options
P = Printer, standard.
M = Internal modem.
A B C CLR = Software Options
A = 0, 2, 4 tanks,
TS-1001 - 0, 2, 4.
B* = S, SCALD, or G, generator.
C** = D - data, F - fax/data software.
C = Continental version.
L = Line leak detection.
R = Reconciliation.
*
SCALD and generator options are
mutually exclusive. The SCALD option
is not needed for the generator model.
**
Data and fax/data modem options are
mutually exclusive.
12"
11"
4"
Fuel Management Systems
TS-1001
15
Tank Sentinel® Consoles
TS-1001/G Fixed Feature Generator
Tank Monitoring Console
The TS-1001/G back-up generator tank monitoring system provides fuel inventory control,
runs status reports and continuous leak detection.
Advantages
• Monitors up to 2 tanks.
• Proven INCON design.
• Easy site-specific programming
through keyboard.
• Accurate inventory information,
including days supply remaining.
• Alarms and positive shut-off available.
• As many as 28 sensor inputs.
• Communicates directly to System
Sentinel™ software.
• Uses highly accurate magnetostrictive
probe technology.
TS-1001/G Console
Ordering Guide
Specifications
Fuel Management Systems
• Number of tanks monitored: 2.
• Input channels: 2 (10*).
• Output only channels: 2 (10*).
• Sensor inputs: 12 (28*).
• Dimensions: 12" × 11" × 4".
• Display type: alphanumeric LCD.
• Applicable liquids: petroleum, chemicals and
hazardous waste.
• Level units: inches or millimeters.
• Volume units: gallons or liters.
• Temperature units: degrees Fahrenheit
or Celsius.
• Display size: 2 lines of 40 characters.
• Power requirements:
115 VAC - +15%, -10%, 100 Watts
maximum, 1 Amp maximum.
230 VAC - +15%, -10%, 100 Watts
maximum, 0.5 Amp maximum.
• Operating temperature: 32° to 122 °F
(0° to 50 °C).
• Storage temperature: -4° to 140 °F
(-20° to 60 °C).
• Intrinsic safety rating:
US - Class I, Div. I, Group D.
• Number of LLDs supported: 8.
• Printer type: 24 column thermal.
Capabilities
• Generates inventory, compliance and fuel
management reports.
• Performs continuous leak detection.
• Supports English and metric units.
• Generates numerous system warnings and
tank alarms to quickly notify the user of any
potential problems.
• Can open and shut appropriate valves
through multipurpose relays.
*
Maximum number when including
additional options.
TS-1001/G, 110 and 220 VAC Models
Model
T1P/2G
V1P/2G
16
Description
One to two tank configuration
with generator back-up capability (110 VAC)
One to two tank configuration
with generator back-up capability (220 VAC)
Console model, software and
hardware options can be listed
separately or combined when
ordering. Systems shipped from the
factory will list the combined part
number. Complete console part
numbers have a specific order and are
created using the following guidelines:
XX PM / 2 G B C
XX = Model
T1 = TS-1001, 120 VAC.
V1 = TS-1001, 220 VAC.
PM = Hardware Options
P = Printer, standard.
M = Internal modem.
2 G B C = Software Options
B* = D - data, F - fax/data software.
C = Continental version.
*
Data and fax/data modem options are
mutually exclusive.
Tank Sentinel® Consoles
Advantages
• Cost-effective system
provides up-to-the-minute
inventory information.
• State-of-the-art
communication capability.
TS-504 and TS-508 Fixed Feature
Inventory Control Consoles
This inventory control family of products offers a feature-rich and cost-effective solution for
continuous inventory management of fuel sites where in-tank leak detection is not required.
• Feature-rich programming
generates detailed inventory
management reports.
• Fully compatible with
System Sentinel™ and System
Sentinel AnyWare™ remote
monitoring software.
Specifications
Applications
The TS-504 and TS-508 family of tank
monitors is the perfect solution for
monitoring and controlling liquid levels in
aboveground tanks at:
• Retail fueling sites.
• Fuel distribution depots.
• Heating oil storage terminals.
• Bulk storage locations for other
motor fluids.
• Bulk fuel terminals.
• Chemical storage plants.
• Many other inventory control applications
not requiring in-tank leak detection.
Capabilities
• Provides real-time, accurate inventory
and delivery information for each
tank monitored.
• Supports up to 24 sensors for sumps,
interstitial spaces and test well applications.
• Can control remote alarms and pumps via
multipurpose, high current relays.
• Self-calibration and diagnostic features
quickly notify users of potential problems.
• Delivers cost-effective overfill protection.
• Can provide sales throughput information
and automated reconciliation of sales and
consumption data when used with the
INCON dispenser interface module.
• Multiple monitors can be easily networked
to support large tank farms and bulk
terminals with more than eight tanks.
• Can be remotely monitored and controlled
via System Sentinel™ remote fuel
management software.
• Supports multiple languages as well as
English and metric units.
Fuel Management Systems
• Number of tanks monitored:
TS-504 - 4.
TS-508 - 8.
• Input channels: 2 (10*).
• Output only channels: 2 (10*).
• Sensor inputs: 8 (24*).
• Dimensions: 12" × 11" × 4".
• Display type: alphanumeric LCD.
• Applicable liquids: petroleum, chemicals and
hazardous waste.
• Level units: inches or millimeters.
• Volume units: gallons or liters.
• Temperature units: degrees Fahrenheit
or Celsius.
• Display size: 2 lines of 40 characters.
• Power requirements:
115 VAC - +15%, -10%, 100 Watts
maximum, 1 Amp maximum.
230 VAC - +15%, -10%, 100 Watts
maximum, 0.5 Amp maximum.
• Operating temperature: 32° to 122 °F
(0° to 50 °C).
• Storage temperature: -4° to 140 °F
(-20° to 60 °C).
• Printer type: 24 column thermal.
Maximum number when including
additional options.
*
17
Tank Sentinel® Consoles
TS-504 and TS-508, 110 VAC Models
Model
T504/4
T504P/4
T508/8
T508P/8
Description
ATG, up to 4 tanks with 8 sensor inputs
ATG, up to 4 tanks with 8 sensor inputs and printer
ATG, up to 8 tanks with 8 sensor inputs
ATG, up to 8 tanks with 8 sensor inputs and printer
TS-504 and TS-508, 220 VAC Models
Model
V504/4C
V504P/4C
V508/8C
V508P/8C
Description
ATG, up to 4 tanks with 8 sensor inputs
ATG, up to 4 tanks with 8 sensor inputs and printer
ATG, up to 8 tanks with 8 sensor inputs
ATG, up to 8 tanks with 8 sensor inputs and printer
TS-504 and
TS-508 Console
Ordering Guide
Console model, software and
hardware options can be listed
separately or combined when
ordering. Systems shipped from the
factory will list the combined part
number. Complete console part
numbers have a specific order and are
created using the following guidelines:
XXXX PM / Y A CLR
XXXX = Model
T504 = TS-504, 120 VAC.
V504 = TS-504, 220 VAC.
T508 = TS-508, 120 VAC.
V508 = TS-508, 220 VAC.
PM = Hardware Options
P = Printer, standard.
M = Internal modem.
Y A CR = Software Options
12"
11"
4"
TS-504/508
Fuel Management Systems
18
Y = 4 or 8 tanks,
TS-504 - 4.
TS-508 - 8.
A* = D - data, F - fax/data software.
C = Continental version.
R = Reconciliation.
*
Data and fax/data modem options are
mutually exclusive.
Tank Sentinel® Consoles
Advantages
• TS-750 compliance tank
gauge includes printer and
optional continuous 24 hour
leak testing (SCALD).
• Capable of multiple alarm modes.
TS-750 Fixed Feature Tank
Monitoring and Compliance Kits
The TS-750 kit is a complete, easy to order and cost-effective solution for your environmental
compliance needs. It provides inventory control and leak detection for sites with up to four
underground storage tanks.
• Uses magnetostrictive technology
probes for unparalleled accuracy.
• Reports product and water levels
in tank.
• Temperature compensated.
• Will accommodate tanks up to
12 feet in diameter.
Specifications
Capabilities
• Number of tanks monitored: 1, 2, 3 or 4.
• Output only channels: 2.
• Sensor inputs: 8.
• Dimensions: 12" × 11" × 4".
• Display type: alphanumeric LCD.
• Applicable liquids: petroleum.
• Level units: inches or millimeters.
• Volume units: gallons or liters.
• Temperature units: degrees Fahrenheit
or Celsius.
• Display size: 2 lines of 40 characters.
• Power requirements:
115 VAC - +15%, -10%, 100 Watts
maximum, 1 Amp maximum.
230 VAC - +15%, -10%, 100 Watts
maximum, 0.5 Amp maximum.
• Operating temperature: 32° to 122 °F
(0° to 50 °C).
• Storage temperature: -4° to 140 °F
(-20° to 60 °C).
• Printer type: 24 column thermal.
• Provides real-time, accurate inventory
and delivery information for each
tank monitored.
• Can accommodate up to 8 sensors and
4 probes.
• Can control remote visual and
audible alarms.
• Delivers cost-effective
environmental compliance.
• Easily programmed to meet
site-specific criteria.
• Consoles can be field upgraded to add
SCALD or internal modem but not
increase tanks.
Fuel Management Systems
• Kits provide for easy ordering and
great value.
19
Tank Sentinel® Consoles
The TS-750 kit consists of the TS-750 compliance monitor, probe(s), float(s) and installation
kit. Please specify the diameter of each tank and the product stored in each tank when
ordering. The following kits are currently available.
TS-750 110 VAC Models
Model
T750P/1
T750P/1S
T750P/2
T750P/2S
T750P/3
T750P/3S
T750P/4
T750P/4S
Description
Single tank kit with 8 sensor inputs and printer
Single tank kit with 8 sensor inputs, printer and SCALD
Two tank kit with 8 sensor inputs and printer
Two tank kit with 8 sensor inputs, printer and SCALD
Three tank kit with 8 sensor inputs and printer
Three tank kit with 8 sensor inputs, printer and SCALD
Four tank kit with 8 sensor inputs and printer
Four tank kit with 8 sensor inputs, printer and SCALD
TS-750 220 VAC Models
Model
V750P/1C
V750P/1SC
V750P/2C
V750P/2SC
V750P/3C
V750P/3SC
V750P/4C
V750P/4SC
Description
Single tank kit with 8 sensor inputs and printer
Single tank kit with 8 sensor inputs, printer and SCALD
Two tank kit with 8 sensor inputs and printer
Two tank kit with 8 sensor inputs, printer and SCALD
Three tank kit with 8 sensor inputs and printer
Three tank kit with 8 sensor inputs, printer and SCALD
Four tank kit with 8 sensor inputs and printer
Four tank kit with 8 sensor inputs, printer and SCALD
Note: The TS-750 kit prices include 4" floats and install kits. 2" floats and install kits are available for an
additional cost. Contact FFS Customer Service for pricing.
TS-750 Console
Ordering Guide
The TS-750 is designed specifically for
underground fuel storage tanks. When
ordering, specify the number of tanks,
the diameter of each tank and the
product type for each tank. INCON
will provide the appropriate TS-750
tank gauge, probes, floats and
installation kits for each site.
Console model, software and
hardware options can be listed
separately or combined when
ordering. Systems shipped from the
factory will list the combined part
number. Complete console part
numbers have a specific order and are
created using the following guidelines:
XXXX PM / Y A B C
XXXX = Model
T750 = TS-750, 120 VAC.
V750 = TS-750, 220 VAC.
PM = Hardware Options
P = Printer, standard.
M = Internal modem.
Y A B C = Software Options
Y = 1, 2, 3 or 4 tanks.
A = S, SCALD.
B* = D - data, F - fax/data software.
C = Continental version.
*
Data and fax/data modem options are
mutually exclusive.
Fuel Management Systems
12"
11"
4"
TS-750
20
Tank Sentinel® Console Accessories
Internal Console Hardware Enhancements
Part Number
Description
TSSP-FDM2
(M) Internal modem, see software enhancements
Console Software Enhancements
Part Number
Description
(S)
Statistical
Continuous
Automatic
Leak
Detection, 24 hour continuous tank
TS-SCALD*
testing software
(D) Data only modem software
TS-DOM2**
(F) Fax and data modem software
TS-FM2**
TS-LLDI***
(L) Line leak detector interface software
(R) Dispenser reconciliation software
TS-Reconciliation****
*
SCALD is not available with inventory control consoles or back-up generator consoles (the S in the console part number identifies
this option). SCALD is used in 24 hour locations for tank leak testing.
**
TSSP-FDM2 internal modem hardware is required (the M before the forward slash in the console part number identifies this
option). Choose data only modem software to support System Sentinel™ software, or choose fax and data modem software when
faxed reports are required.
***
Electronic line leak detector hardware is required (the L in the console part number identifies this option). This interface software
enables line leak detector compliance reporting and line leak test scheduling capability. Not available on the TS-750 console.
****
TS-DIM dispenser interface module hardware is required (the R in the console part number identifies this option). This option
provides automated inventory reconciliation. Not available on the TS-750 console.
Upgrading Installed Tank Sentinel® Consoles
Upgrade
Internal modem
Description
TSSP-FDM2 internal modem hardware
TS-DOM2 data only modem software or TS-FM2 fax and data software
24 hour leak
detection
TS-SCALD statistical, continuous automatic leak detection software
Line leak
Appropriate TS-LS300 or TS-LLD
TS-LLDI line leak detector interface software
Automated
Appropriate TS-DIM dispenser interface module
inventory
TS-Reconciliation dispenser reconciliation software
reconciliation
Note: When placing order to upgrade installed consoles, the serial number of the console to be upgraded must be supplied.
Paper Supplies
Fuel Management Systems
Part Number
Description
TS-TP2
One box of 5 rolls of thermal printer paper for Tank Sentinel® consoles
TS-TP2C
One case of 20 boxes of 5 rolls of thermal printer paper for Tank Sentinel® consoles
21
External Console Hardware
S940 Sensor Alarm Console
The S940 Sensor Alarm Console is a cost effective solution for tank overfill protection and
sensor leak detection needs. This easy-to-install-and-operate device monitors up to four
tanks, containment sumps or interstitial spaces and provides an audible and visual indication of
an alarm condition. Two programmable relay outputs are included to sound an external alarm
or send a signal to a building control or monitoring system. The weather proof enclosure
allows the S940 Sensor Alarm Console to be conveniently installed indoors or out.
Advantages
• Monitors up to 4 sensors for overfill
or leak detection
• Simple to install and configure
• Can be installed indoors or outdoors
• Cost effective leak detection or
overfill solution
• Connect to remote alarms or
external devices
Fuel Management Systems
Specifications
Capabilities
• Input channels: 4
(2-wire float switch sensor inputs)
• Output channels: 2
(dry contact relay outputs)
• Internal audible alarm
• Alarm, power and output LEDs
• Compatible Franklin Fueling Systems
2-wire sensors
• TSP-ULS universal liquid sensor
• TSP-HLS high level sensor
• TSP-HFS horizontal float switch
• TSP-UHS universal hydrostatic sensor
• Dimensions 6" x 6" x 4"
• Power requirements: 100-240 VAC
+/- 10%, 50/60 Hz, 15 W max
• Operating temperature: -13 to +140 ºF
(-25 to +60 ºC)
• Enclosure: NEMA 4, indoor / outdoor
(non-hazardous locations only)
• Tank overfill alarm
• Steel or fiberglass tank
interstitial monitoring
• Containment sump monitoring
• General liquid sensor monitoring
• Programmable relay outputs for remote
alarm or external device interface
Model
S940
22
Approvals
• UL, cUL, associated apparatus, non
hazardous location
• Provides intrinsically safe circuits for
sensors located in Class 1, Div 1, Group D
hazardous location
Description
Four channel sensor alarm console
Electronic Line Leak Detectors
Advantages
• Automatically learns exact
pipeline characteristics.
• No pipe type and length
programming required.
TS-LS300 AutoLearn™
The TS-LS300 AutoLearn™ line leak detection system learns the exact characteristics of each
line, ensuring unparalleled accuracy. It can run independently or with any INCON TS-1001,
TS-2001, TS-504 or TS-508 tank gauge.
• Monitors flexible, steel and/
or fiberglass pipelines in any
combination up to certified
maximum values.
• Works with submersible pumps
generating 25 psi or more.
• Automatically performs 3.0 gph,
0.2 gph and 0.1 gph line tests.
• Positive submersible pump shutdown
in the event of a leak.
• Can be monitored through ATG
and System Sentinel™.
• Third party certified for 0%
probability of false alarm.
• For use in rigid, flex and rigid/flex
piping configuration.
• Immediate notification of
alarm condition.
• Allows printed compliance reports.
Console Specifications
• Number of lines monitored: 1, 2, 3 or 4.
• Dimensions: 11" × 12" × 4".
• Power requirements:
115 VAC - +15%, -10%, 100 Watts
maximum, 1 Amp maximum.
230 VAC - +15%, -10%, 100 Watts
maximum, 0.5 Amp maximum.
• Operating temperature: 20° to 122 °F
(10° to 50 °C).
• Intrinsic safety rating: Associated Apparatus
II (1) G [EEX la] IIA.
Leak Sensing Transducer
Specifications
• Number of lines monitored: 1.
• Dimensions: 6-1/4" × 2" NPT.
• Applicable liquids: motor fuels.
• Power requirements:
10 to 20 VDC from console.
• Operating temperature: -40° to 149 °F
(-40° to 66 °C).
• Operating pressure: 0 to 100 psi
(0 to 689 kPa).
• Belden cable: #9363-22 AWG, #9364-20
AWG or #9365-18 AWG.
• Max. sensor to console cable distance:
500' (152.4 M).
• Sensor port fitting: 2" female NPT.
• Sensor material: anodized aluminum body
and stainless steel sensor.
• Intrinsic safety rating: Class 1, Div. 1,
Group D, II (1) G [EEX la] IIA T4
• Explosion proof: Class 1, Div. 1, Group D.
Capabilities
• The TS-LS300 performs a 3.0 gph leak
and pressure test after every dispense.
Upon detection of a failed test, the LS300
will alarm and positively shutdown the
affected turbine.
• The TS-LS300 continuously monitors
pressurized lines for thermally stable
conditions and performs a 0.2 gph monthly
and 0.1 gph annual precision leak test
during the thermally stable union.
• AutoLearn™ line leak detection
technology is also available with the
TS-LS500, part of the TS-550 and TS-5000
fuel management systems.
Fuel Management Systems
• Eliminates the need for factory
calibration or on-site field judgments
for set-up.
23
Electronic Line Leak Detectors
TS-LS300, 115 VAC 50/60 Hz Models
Intrinsically Safe
For new installations where separate low voltage conduits can be used.
11"
Model
Description
TS-LS300/2
2-line console with line calibration kit
TS-LS300/3
3-line console with line calibration kit
TS-LS300/4
4-line console with line calibration kit
Note: All AutoLearn™ models include the TPI turbine pump interface module.
12"
Explosion Proof
For retrofit installations where only a high voltage conduit can be used.
Model
Description
TS-LS300E/2 2-line console with line calibration kit
TS-LS300E/3 3-line console with line calibration kit
TS-LS300E/4 4-line console with line calibration kit
Note: All AutoLearn™ models include the TPI turbine pump interface module.
TS-LS300, 230 VAC 50/60 Hz Models
4"
TS-LS300
2.38" ACROSS
FLATS
Intrinsically Safe
For new installations where separate low voltage conduits can be used.
¾" NPT
Model
Description
VS-LS300/2
2-line console with line calibration kit
VS-LS300/3
3-line console with line calibration kit
VS-LS300/4
4-line console with line calibration kit
Note: All AutoLearn™ models include the TPI turbine pump interface module.
Interface Cable
For connecting two AutoLearn™ consoles together.
6.25"
5.13"
Model
Description
TSSP-ALICBL AutoLearn™ interface cable
Alternative Fuels Accessories
Model
TS-AFALNIP
Description
Leak generator needle valve kit required for E85 installations
2" NPT
TS-LSU300 TRANSDUCER
Fuel Management Systems
24
Electronic Line Leak Detectors
Advantages
• The TS-LLD leak detector performs
gross leak tests after each 3.0 gph
dispense, the monthly 0.2 gph test
and the annual 0.1 gph test.
Line Sentinel™
The INCON TS-LLD line leak detector uses patented, flow-based technology to perform
multiple line tightness tests.
• Performs positive shutdown if a leak
is detected.
• Tests performed at full pump
pressure to ensure integrity of lines.
• Carries numerous
regulatory approvals.
• Low-cost, wireless installation
retrofits easily into the existing
submersible turbine pump housings
without excavation.
Specifications
Applications
The TS-LLD can be used in most pressurized
applications, in any new or existing turbine
pump housing and can be used in place of a
mechanical leak detector.
• Third party certified with 100% probability
of leak detection and a 0% probability of
false alarm.
• Supports rigid, fiberglass and flexible
piping systems.
• Line leak test failure indicated by alarm.
• Works as a stand-alone unit or interfaced
with INCON Tank Sentinel® consoles.
Note: The presence of the integral in-line
check valve of the TS-LLD during
normal operation creates a pressure
drop which will reduce the total
flow potential of the submersible
pump. Some of the pressure drop
can be compensated by upgrading the
submersible pump motor. To ensure
desirable flow rates are achieved, we
do not recommend TS-LLD in the
following sites:
• where it is imperative to achieve
10 gpm.
• sites that frequently have more than
4 nozzles open at a time.
In such cases we recommend our
AutoLearn™ pressure-based electronic
leak line detector.
Capabilities
The INCON TS-LLD line leak detector
performs a variety of tests for
environmental compliance.
• Eliminates slow-flow problems associated
with mechanical leak detectors.
• Immediately identifies leaks even in
changing thermal conditions, unlike
mechanical LLDs.
• Performs continuous testing using highly
sensitive volumetric flow technology.
• Continuously performs self-diagnostic test
to ensure proper system operation.
Fuel Management Systems
• Dimensions:
Console - 4-3/8" × 3-3/8" × 2-5/16".
Line leak detector - 23-1/2" × 2-3/8".
• Applicable liquids: gasoline and diesel
motor fuels.
• Gross leak test (3.0 gph): yes.
• Monthly test (0.2 gph): yes.
• Annual test (0.1 gph): yes.
• Indicates days since 0.2 gph test passed: yes.
• LED unit: yes.
• Positive shut-down: yes.
• Tank Sentinel® interface: yes.
25
Electronic Line Leak Detectors
Model
Description
Electronic line leak detector with an FE Petro installation adapter, one
TS-LLD/FE
required for each submersible pump
Electronic line leak detector with a Red Jacket installation adapter, one
TS-LLD/RJ
required for each submersible pump
Electronic line leak detector with a Red Jacket Quantum installation
TS-LLD/RJQ
adapter, one required for each submersible pump
Note: RJ represents Red Jacket, a trademark of Veeder-Root Co.
CABLE
ADAPTER
REQUIRED
23.50"
4.50"
MOUNTED
HEIGHT
6.50"
2" NPT
TS-LLD
3.35"
Fuel Management Systems
4.35"
2.31"
0.60"
TS-LLD CONTROL UNIT
26
Probes and Sensors
Advantages
• Easy to use and install.
• Uses innovative, magnetostrictive
position measurement technology to
report liquid levels.
• Highly stable performance.
• Unparalleled accuracy and
performance when used with a
Franklin Fueling Systems Automatic
Tank Gauge.
• Screw-in electrical connector
provides quick installation or
removal eliminating the need to
resplice wires.
• Intrinsically safe circuits for
hazardous locations.
Leak Detection and Inventory
Control Probes
TSP-LL2 liquid level probes are advanced instruments that use magnetostrictive position
measurement technology to accurately report inventory levels in storage tanks.
Theory of Operation
Specifications
• Operating temperature: -40° to 140 °F
(-40° to 60 °C).
• Storage temperature: -40° to 158 °F
(-40° to 70 °C).
• Intrinsic safety rating: Class 1, Div. 1,
Group D.
• Non-linearity: ±0.025% of full scale.
• Repeatability: ±0.001".
• Temperature sensors: Up to 5 thermistors
located in the shaft.
• Temperature resolution: ±0.02 °F
(±0.01 °C).
• Probe pigtail: Two 10' long conductor
cables with shields and polyurethane jacket.
• Interface cable:
0' to 200' - Belden 87760.
0' to 400' - Belden 87761.
0' to 1500' - Belden 89182.
Consult factory for others.
• Shaft, E-ring and washer materials:
Housing - #316 stainless steel anodized
aluminum, MIL-A-8625C, Type 2, Class 2.
Floats - nitrophyl, Kynar and
nickel plated brass.
• Float kits must be ordered separately.
• The TSP-LL2-I probe is used for
aboveground storage tanks, chemical or oil
waste, and inventory only applications.
• Probes are available in many sizes that are
suitable for all common tanks.
• Easily installed into 4" riser pipes or
optionally into 3" or 2" riser pipes with
reducer fitting.
Capabilities
• Probes can report the level of one or
two floats.
• The TSP-LL2 is capable of precise leak
detection, density measurement and
inventory monitoring.
• The TSP-LL2-1 is capable of density
measurement and inventory monitoring.
• Use the appropriate FFS installation kit to
suspend all TSP-LL2 probes and TSP-LL2-I
probes doing density measurement.
• TSP-LL2-1 probes include hardware for
tank bottom installation when not
performing density measurement.
• Float kits must be ordered separately.
Fuel Management Systems
• An electromagnetic field is created
inside the probe head and forms
around a long waveguide within
the probe shaft when position
measurements are taken.
• The electromagnetic field interacts
with the magnetic field of the
float(s) and produces a shock wave
in the waveguide that travels at a
known speed.
• When the shock wave is detected at
the probe head, the probe creates a
signal that corresponds precisely to
the product level.
• Product expansion calculations are
enabled by temperature sensors that
are located at various points in the
probe shaft.
Applications
The LL2 Series of liquid level probes feature
exceptional linearity, resolution and stability,
and are used in underground and
aboveground storage tanks. Two types of
probes are manufactured for use with
Franklin Fueling Systems Automatic Tank
Gauges.
• The TSP-LL2 probe is used for
underground storage tanks and
petroleum applications when static or
SCALD leak detection is required.
27
Probes and Sensors
Model
Description
TSP-LL2-29
2' diameter tank probe
TSP-LL2-41
3' diameter tank probe
TSP-LL2-53
4' diameter tank probe
TSP-LL2-65
5' diameter tank probe
TSP-LL2-69
5'4" diameter tank probe
TSP-LL2-77
6' diameter tank probe
TSP-LL2-81
6'4" diameter tank probe
TSP-LL2-89
7' diameter tank probe
TSP-LL2-101 8' diameter tank probe
TSP-LL2-113 9' diameter tank probe
TSP-LL2-125 10' diameter tank probe
TSP-LL2-131 10'6" diameter tank probe
TSP-LL2-137 11' diameter tank probe
TSP-LL2-149 12' diameter tank probe
Notes: 1. Custom probe lengths are available; contact factory for price and delivery.
2. These probes are used with all Franklin Fueling Systems ATG consoles.
3. Float kits must be ordered separately.
Fuel Management Systems
Model
Description
TSP-LL2-29-I 2' diameter tank probe
TSP-LL2-41-I 3' diameter tank probe
TSP-LL2-53-I 4' diameter tank probe
TSP-LL2-65-I 5' diameter tank probe
TSP-LL2-69-I 5'4" diameter tank probe
TSP-LL2-77-I 6' diameter tank probe
TSP-LL2-81-I 6'4" diameter tank probe
TSP-LL2-89-I 7' diameter tank probe
TSP-LL2-101-I 8' diameter tank probe
TSP-LL2-113-I 9' diameter tank probe
TSP-LL2-125-I 10' diameter tank probe
TSP-LL2-131-I 10'6" diameter tank probe
TSP-LL2-137-I 11' diameter tank probe
TSP-LL2-149-I 12' diameter tank probe
TSP-LL2-161-I 13' diameter tank probe
TSP-LL2-173-I 14' diameter tank probe
TSP-LL2-185-I 15' diameter tank probe
TSP-LL2-197-I 16' diameter tank probe
TSP-LL2-209-I 17' diameter tank probe
TSP-LL2-221-I 18' diameter tank probe
Notes: 1. Orders for probes larger than 149" cannot be canceled and are non-returnable.
2. These probes are used with Franklin Fueling Systems ATGs.
3. Liquid level inventory only probe.
4. Float kits must be ordered separately.
28
2.00"
2.88"
6.38"
Probes and Sensors
Advantages
• Can be used in any tank up to
50' high.
• Suitable for all petroleum and many
industrial applications.
Moorman Level Gauge Kit
The Moorman level gauge kit includes the complete Moorman gauge (7S for 35' tanks and
9S for 50' tanks) and the appropriate length magnetostrictive inventory probe. The Moorman
level gauge retrofit kit includes the appropriate length magnetostrictive inventory probe and
probe mounting accessories. TSP-UVPK ultraviolet protection kit is included.
• Available as a complete system
or retrofit.
TSP-MLGKSS-35-M
TSP-MLGK-50
TSP-MLGKSS-50
TSP-MRFK-35
TSP-MRFK-50
Description
Standard gauge kit for vertical tanks up to 35'
Standard gauge for vertical tanks up to 35' with metric display
Standard gauge for tanks up to 35' with stainless steel tape and float
Standard gauge for tanks up to 35' with metric display, with stainless steel tape
and float
Standard gauge for vertical tanks up to 50'
Standard gauge for tanks up to 50' with stainless steel tape and float
Retrofit gauge kit for vertical tanks up to 35'
Retrofit gauge kit for vertical tanks up to 50'
Fuel Management Systems
Model
TSP-MLGK-35
TSP-MLGK-35-M
TSP-MLGKSS-35
29
Probes and Sensors
Float Kits
2", 3" and 4" Float Kit
Advantages
• Designed for applications involving 2",
3" or 4" riser pipes.
• Each float set contains a product and
water float.
• Constructed of nitrile rubber water
float containing a nickel plated ballast
that is compatible with a wide variety
of petroleum products.
• 2" water floats are stamped G for
gasoline and D for diesel.
• 3" and 4" water floats are colored
red for gasoline and blue for diesel.
TSP-SSP Chemical
Float Advantages
Model
Description
TSP-IDF2
2" float set for diesel tanks
TSP-IGF2
2" float set for gasoline tanks
TSP-IDF3
3" float set for diesel tanks
TSP-IGF3
3" float set for gasoline tanks
TSP-IDF4
4" float set for diesel tanks
TSP-IGF4
4" float set for gasoline tanks
TSP-LPGF
2" float for LPG tanks, with or without isolation sleeve
TSP-SSP
2-1/16" OD, #316 stainless steel float for chemical applications only
Note: Order one float set for each LL2 Mag probe.
• #316 stainless steel product float
with 2-1/16" OD.
• Suitable for use in a wide variety of
chemical applications, consult factory
for chemical compatibility issues.
• Use one float per TSP-LL2-I probe.
• Float specific gravity 0.55 to 0.63.
• Collapse pressure 500 psi/g minimum.
LPG Float Advantages
• Designed for applications involving
tank openings of at least 2".
• Single float used for monitoring the
level of LPG (propane) fuel.
• Suitable for monitoring
pressurized products.
Fuel Management Systems
• For use in USTs or ASTs with
TSP-LL2 or TSP-LL2-I probes.
TSP-LPG/EU float can be used with
locally supplied tank isolation sleeves.
30
Probes and Sensors
Advantages
• Designed for applications involving
4" riser pipes.
• Each float set contains a product,
density and water float.
• Floats are constructed of nitrile
rubber and are nickel plated.
• Water and product floats are
colored red for gasoline and blue
for diesel.
• Density and product floats are
calibrated and must be maintained
as a set.
Density Measurement Float Kit
The Colibri and T5 Series fuel management systems have the ability to continuously monitor
the density of fuel stored in underground and aboveground storage tanks. The same LL2
magnetostrictive probe that provides inventory management and leak detection capabilities
can also supply product density without the addition of extra probes or sensors.
Programmable high and low density alarm points allow the user to determine the range of
acceptable density fluctuations.
2.00"
2.88"
7.00"
SPACER
Theory of Operation
3"
FLOAT
PROBE
SHAFT
LENGTH
=
MODEL
NO.
DENSITY
FLOAT
WATER
FLOAT
(OPTIONAL)
Part Number
Description
Density Range
TSP-IDF4D
Diesel/fuel oil density float kit
790-900 kg/m3
TSP-IGF4D
Gasoline density float kit
690-800 kg/m3
Note: Order one density measurement float kit for each magnetostrictive probe. Probes used with density
float kits must have serial numbers greater than 6000000.
Fuel Management Systems
Density measurement is based on the
distance between the calibrated
product and density floats. As the
density of the fuel changes, the gap
between the floats will increase or
decrease in proportion to the change.
The tank gauge receives this
information from the probe and uses
it to calculate and display the current
density of the fuel.
31
Probes and Sensors
Probe Installation Kits
Probe installation kits are used to install TSP-LL2 liquid level probes in underground tank
applications. They are designed to allow the probe to be suspended in either 2" or 4" riser
pipes. This method of installation guarantees that the probe can provide accurate level
information and that the tank is sealed in accordance with regulatory requirements. It also
provides excellent protection for the probe. The probe installation kit makes it easy to install
TSP-LL2 liquid level probes properly and safely. The probe installation kit actually suspends
the level probe from the top of the riser. The kit is designed so that the probe and cable do
not twist during installation and so the cable is sealed and strain relieved. It also allows easy
access to the probe for inspection if required. The probe installation kit allows you to install
level probes in almost any underground tank. It works equally well in fiberglass and steel tanks
and can be adjusted to accommodate tanks buried at almost any depth.
Part Number
Description
TSP-K2A
Mag probe install kit for 2" riser pipes
TSP-K2B
Mag probe install kit for 2" riser pipes with BSP threads
TSP-K4A
Mag probe install kit for 4" riser pipes
TSP-K4AS
#316 stainless steel mag probe install kit for 4" riser pipes
TSP-K4B
Mag probe install kit for 4" riser pipes with BSP threads
TSP-LPGK
LPG probe install kit, 149" maximum LL2 probe length
Note: TSP-LPGK install kit is not needed when locally supplied tank isolation sleeve is utilized.
Cables
Fuel Management Systems
Part Number
Description
600-0042
Belden #87761, runs up to 500' (500' rolls)
600-0055
Belden #89182, runs 500' to 1,500' (500' rolls)
600-0080
Quick disconnect probe cable
Notes: 1. Cable is sold in 500' rolls.
2. Use only these cables with the TSP-LL2 and TSP-LL2I probes.
Accessories
Part Number
TSP-DB1
TSP-DB10
TSP-DBTOOL
TSP-KW30
TSP-UVPK
Description
One direct burial splice connector kit
Pack of 10 direct burial splice connector kits
Epoxy dispensing tool
Pack of 30 3M splice connectors
Ultraviolet protection kit - protects probe electronics when installed in
AST applications
Notes: 1. Use the TSP-DB1 or TSP-DB10 for direct burial cable applications or when weatherproof junction boxes are not used.
2. The DBTOOL is required to dispense the epoxy.
3. Each direct burial splice connector kit includes a receptacle, three splice connectors and epoxy
for the dispensing tool.
32
Advantages
• The TSP-K4AS install kit is for use
with chemical or other installations
where it is desireable for the probe
head to be outside of the riser. It
consists of a #316 SS 4" cap and
compression fitting that is installed
on the probe shaft so that only the
floats and shaft are exposed to the
tank contents. Includes TSP-UVPK
probe head protection kit.
• The TSP-LPGK install kit is for use
with pressurized LPG tanks where
the probe head will reside outside
of the tank opening. It consists
of a special compression fitting,
designed to retain the contents of
the pressurized tank, that is installed
on the probe shaft and then inserted
into a user supplied cap with a 3/4"
NPT hole. Includes TSP-UVPK probe
head protection kit.
Probes and Sensors
Application
For liquid-filled tank
interstitial monitoring.
Advantages
• Versatile sensor for virtually all
fiberglass double wall tanks equipped
for hydrostatic leak detection.
TSP-HIS Hydrostatic Interstitial
Brite™ Sensor
The TSP-HIS hydrostatic interstitial Brite™ sensor detects leaks in double wall tanks where
the interstitial space is filled with a liquid brine solution. For use with all Tank Sentinel® and
fuel management systems, the TSP-HIS polyester, nitrile and epoxy construction is compatible
with all types of brine.
• Microcomputer monitors liquid
at varying levels within tanks and
relays digitally encoded status
information via the fail-safe Brite™
sensor digital communication system
to fuel management system or Tank
Sentinel® consoles, alerting of any
alarm conditions.
Installation
• Lower TSP-HIS to the bottom of the
brine reservoir of double wall tank.
• Sensors include the TSP-KV4 vented
4" riser cap.
Model
Description
TSP-HIS
Hydrostatic interstitial Brite™ sensor, 11"*
TSP-HIS-XL
Hydrostatic interstitial Brite™ sensor, 21"*
TSP-KV4
Hydrostatic sensor vented riser pipe cap kit for 4" riser pipes
Note: This sensor communicates with the console using 3 wires.
*Not including cable.
Fuel Management Systems
• The normal brine level should reside
half way up the sensor.
33
Probes and Sensors
TSP-DIS Discriminating Interstitial
Brite™ Sensor
The TSP-DIS discriminating interstitial Brite™ sensor detects the presence of various liquids
in tanks as well as sumps and other locations. The TSP-DIS is designed to interface with the
Tank Sentinel® and fuel management system.
Application
For dry tank interstitial monitoring.
Advantages
• Installs in the interstitial space of
steel and fiberglass double wall tanks
and sumps.
• Uses light beam traveling through
probe to determine if sensor is wet.
• Microprocessor inside sensor
interprets readings and communicates
data to the Tank Sentinel® and fuel
management system.
Model
Description
TSP-DIS
Discriminating interstitial Brite™ sensor
TSP-KI2
Interstitial sensor riser cap kit for 2" riser pipes
Note: This sensor communicates with the console using 3 wires.
• Fail-safe digital communications with
built-in alarm if sensor malfunctions.
• Sensor can distinguish between
petroleum and water.
• Alarms indicate petroleum
present, water present and
sensor malfunction.
Installation
Each TSP-DIS comes with 25' of
oil-resistant cable. For fiberglass tanks,
TSP-DIS is pulled into the interstitial
space using a “fish” string or wire.
For steel interstitial tanks, TSP-DIS is
lowered directly to the bottom of
the interstitial space through a
2" NPT fitting provided for that
purpose on the tank. Optional
installation kits are available which
include a riser cap and other parts
required to complete installation.
Fuel Management Systems
34
Probes and Sensors
Application
For dry tank interstitial monitoring.
Advantages
• Highly accurate electro-optic
technology and closed output circuit
ensures that leaks are detected.
TSP-EIS Electro-Optic
Interstitial Sensor
The TSP-EIS electro-optic interstitial sensor may be used with all Tank Sentinel® and fuel
management system consoles. Utilizing electro-optic technology and made of chemically
resistant polysulfone plastic, the TSP-EIS may be installed in sumps, double wall tanks or other
locations where the presence of liquid indicates a leak has occurred.
• Chemical-resistant materials.
• Can be installed in fiberglass or steel
double wall tanks.
• Utilizes light emitting diodes
and prisms to indicate if a leak
has occurred.
Each TSP-EIS comes with 25' of
oil-resistant cable. For fiberglass
tanks, TSP-EIS is pulled into the
interstitial space using a “fish” string
or wire. For steel interstitial tanks,
TSP-EIS is lowered directly to the
bottom of the interstitial space
through a 2" NPT fitting provided for
that purpose on the tank. Optional
installation kits are available which
include a riser cap and other parts
required to complete installation.
Model
Description
TSP-EIS
Electro-optic interstitial sensor
TSP-K12
Interstitial sensor riser cap kit for 2" riser pipes
Note: This sensor communicates with the console using 3 wires.
Fuel Management Systems
Installation
35
Probes and Sensors
TSP-ULS Liquid Sensor
The TSP-ULS liquid sensor is a low cost sensor which may be used with all Tank Sentinel®
and fuel management system consoles. This sensor is also compatible with S940 Sensor Alarm
Console. Based on float-switch technology and made of chemically resistant materials, the TSPULS may be installed in sumps, dispenser pans, steel double wall tanks or other locations where
the presence of liquid indicates a leak has occurred.
Application
For dry steel tank interstitial and
containment sump monitoring.
Advantages
• Highly reliable float technology and
closed output circuit ensures that
leaks are detected.
• Chemical-resistant materials assure
compatibility with most liquids.
Installation
Model
Description
TSP-ULS
Universal liquid sump sensor
TSP-K12
Interstitial sensor riser cap kit for 2" riser pipes
Note: This sensor communicates with the console using 2 wires.
TSP-UHS
Universal Hydrostatic Sensor
The TSP-UHS Universal Hydrostatic Sensor uses float switch technology to continuously
monitor liquid filled double wall containment sumps. Normally submerged, the single float TSPUHS will provide an indication if there is a loss of monitoring liquid.
Each TSP-ULS comes with a 25' cable.
1/2" NPT thread is provided on the
compression gland fitting attached to
the sensor’s cable, allowing it to be
suspended from standard electrical
boxes and fittings. The sensor may be
positioned vertically by adjusting
cable length. For steel interstitial
tanks, TSP-ULS is lowered into the
opening provided on the tank and
is suspended by optional TSP-KI2
installation kit. Other mounting
methods available depending upon
application and location.
Application
Typically used for hydrostatic
monitoring of the liquid in a double
wall sump interstice.
Advantages
Fuel Management Systems
• Highly reliable float technology and
closed output circuit ensures that
leaks are detected.
• Chemical-resistant materials.
Installation
Model
TSP-UHS
HM-KIT
36
Description
Universal Hydrostatic Sensor
Hydrostatic monitoring installation kit.
Includes: flexible brine tube, sensor housing clamp, sensor housing, sensor
cap and hardware
Note: This sensor communicates with the console using 2 wires.
Each TSP-UHS comes with a 25'
cable. The sensor can be installed
into the reservoir of a liquid filled
double wall containment sump. The
sensor must be installed in a vertical
position at a level where it is normally
submerged. The TSP-UHS will alert
if the liquid level drops below the
bottom of the sensor.
Probes and Sensors
Application
For containment sump monitoring.
Advantages
• Utilizes proven magnetostrictive
technology.
• Water warning, water alarm and
product alarm.
TSP-DMS Discriminating
Magnetostrictive Sensor
The TSP-DMS is a fast acting discriminating sensor that utilizes magnetostrictive technology
to provide reliable monitoring of dispenser pans and containment sumps. Its floats can detect
the presence of water or hydrocarbons and also ensure that the sensor installation has not
been tampered with. The TSP-DMS can report water warnings and programmable water alarm
points as well as product alarms. The TSP-DMS is used with fuel management system consoles.
• Tamper protection feature will
alarm if sensor is moved from
installed position.
• Will alarm and recover quickly when
hydrocarbons are present.
Model
TSP-DMS-12
TSP-DMS-24
TSP-KS
Description
Discriminating magnetostrictive sensor, 12"
Discriminating magnetostrictive sensor, 24"
Uni-Strut® mounting kit
Fuel Management Systems
Notes: 1. For use with the T5 Series fuel management systems.
2. This sensor communicates with the console via the TS-PRB probe module.
3. Requires Controller Module software version 9.5 or greater.
37
Probes and Sensors
TSP-DDS Discriminating Dispenser
Sump Brite™ Sensor
The TSP-DDS is a discriminating dispenser sump Brite™ sensor which provides reliable
monitoring of dispenser pans and containment sumps. Combining magnetic float switch
sensors with an innovative polymer strip, the TSP-DDS generates three different alarms for
the detection of hydrocarbons, for liquid in sump and when the sump is full. The TSP-DDS
may be used with both fuel management system and Tank Sentinel® consoles.
Application
For containment sump monitoring.
Advantages
• Uses magnetic float switches to
detect liquid at two levels.
• Innovative polymer strip detects
hydrocarbons along sensor and
floating on water.
• Compatible with common fuels
and chemicals.
• Detects liquid at 1-1/2" from base.
• Detects hydrocarbons on sensor and
floating on water.
• Digitally encoded status information
sent from microcomputer to console
from 775+ feet.
Model
Description
TSP-DDS
Discriminating dispenser sump Brite™ sensor
TSP-KS
Uni-Strut® mounting kit
Note: This sensor communicates with the console using 3 wires.
• Alarms to indicate liquid in sump,
hydrocarbon detected, sump is full
and sensor malfunction.
Installation
Variety of mounting methods possible
depending on location. Bracket
provided for quick installation.
TSP-DTS Discriminating Turbine
Sump Brite™ Sensor
Fuel Management Systems
The TSP-DTS is a discriminating turbine sump Brite™ sensor that detects the presence
of liquid and hydrocarbons when installed in turbine and containment sumps. TSP-DTS is
designed to interface with Tank Sentinel® and fuel management system.
Application
For containment sump monitoring.
Advantages
• Uses magnetic float switches to
detect liquid at two levels.
• Innovative polymer strip detects
hydrocarbons along sensor and
floating on water.
• Compatible with common fuels
and chemicals.
• Detects liquid at 1-1/2" from base.
• Detects hydrocarbons on sensor and
floating on water.
• Digitally encoded status information
sent from microcomputer to console
from 775+ feet.
Model
Description
TSP-DTS
Discriminating turbine sump Brite™ sensor
TSP-KS
Uni-Strut® mounting kit
Note: This sensor communicates with the console using 3 wires.
38
• Alarms to indicate liquid in sump,
hydrocarbon detected, full sump and
sensor malfunction.
Probes and Sensors
Application
For use in dry monitoring wells.
Advantages
• Detects vapor, gas and rising
groundwater when installed in a
monitoring well.
TSP-DVS Discriminating Vapor
Brite™ Sensor
The TSP-DVS is a discriminating vapor Brite™ sensor that detects the presence of gas or
vapor molecules when installed in dry monitoring wells or containment space where vapor
detection is necessary. TSP-DVS is designed to interface with the Tank Sentinel® and fuel
management system.
• Fail-safe digital communication with
built-in alarm if sensor malfunctions.
• Senses ambient temperature to
minimize false alarms.
• Equipped with twenty feet of
oil-resistant cable for installation in
2" and 4" monitoring wells located
around underground tanks.
• Senses vapor, gas and groundwater.
• Communicates with console from
775+ feet.
• Alarms to indicate
sensor malfunction.
Model
TSP-DVS
TSP-KW4
Description
Discriminating vapor Brite™ sensor
Vapor sensor monitoring well pipe cap kit for 4" riser pipes
Note: This sensor communicates with the console using 3 wires.
Application
For use in wet monitoring wells.
Advantages
• Unique alarms for the detection
of hydrocarbons or decreased
groundwater levels.
TSP-MWS Monitoring Well
Brite™ Sensor
The TSP-MWS monitoring well Brite™ sensor is a discriminating liquid sensor which detects
the presence of hydrocarbon floating on groundwater. Using a float switch and innovative
conductive polymer strip, the TSP-MWS identifies hydrocarbons anywhere along the length of
the sensor.
Fuel Management Systems
• Completely reusable even after
several exposures to hydrocarbons.
• Available in four different lengths to
accommodate well depth.
• Microcomputer within
TSP-MWS detects presence of
hydrocarbons and alerts Tank
Sentinel® and fuel management
system of alarm conditions via
digitally-encoded information.
Installation
• Normally installed in 4" groundwater
monitoring wells.
• Integral well cap may be locked
with standard padlock to prevent
unauthorized access.
Model
Description
TSP-MWS-10
Monitoring well Brite™ sensor, 10'
TSP-MWS-15
Monitoring well Brite™ sensor, 15'
TSP-MWS-20
Monitoring well Brite™ sensor, 20'
TSP-MWS-25
Monitoring well Brite™ sensor, 25'
Note: This sensor communicates with the console using 3 wires.
39
Probes and Sensors
TSP-HLS Level Sensor
The TSP-HLS level sensor is an overfill prevention switch which is compatible with all Tank
Sentinel® and fuel management system consoles. This sensor is also compatible with S940
Sensor Alarm Console. It may be adjusted to operate over a wide range of levels. The TSPHLS is based on float-switch technology and is made of chemical-resistant materials to assure
compatibility with most liquids. Each sensor is supplied with jacketed cable five feet in length.
The TSP-HLS’s normally closed output circuit provides supervised operation, ensuring that
broken wires and similar failures will not go undetected.
The TSP-HLS is installed in a 2" NPT fitting on the tank. The level at which it operates may be
adjusted by loosening a fitting and moving the sensor’s shaft in or out of the tank as required.
Model
TSP-HLS-15
Description
High product level sensor, 15" long, installed in tank
High product level sensor, stainless steel 15" long, installed in tanks containing
TSP-HLS-15/SS
alternative fuels
TSP-HLS-30
High product level sensor, 30" long, installed in tank
High product level sensor, stainless steel 30" long, installed in tanks containing
TSP-HLS-30/SS
alternative fuels
Note: This sensor communicates with the console using 2 wires.
Fuel Management Systems
40
Application
Overfill protection switch.
Theory of Operation
The secret to the TSP-HLS’s reliability
is its float switch technology. A small
magnetically-activated reed switch is
located inside the body of the sensor.
Tiny magnets are positioned inside a
lightweight float which is free to move
up and down along the shaft so that
the magnets are below the reed switch.
When the sensor is immersed in liquid,
the float rises and the magnet activates
the reed switch, signaling the console
that the high limit has been reached.
Probes and Sensors
Advantages
• Supplied with a cord grip and butt
splices for wiring connections.
• Easily installs into a two-inch riser
pipe with a compression fit against
the walls of the pipe.
TSP-K12 Interstitial Sensor Riser
Cap Installation Kit
Installation kit for installing the TSP-DIS, TSP-EIS or TSP-ULS in dry interstitial spaces with
2" riser pipe openings.
• Provided with security holes that fit
a padlock to prevent unauthorized
access into the riser pipe.
Model
TSP-K12
• The riser cap is compression fit into
a 4" riser pipe via the use of a lever.
• Supplied with a cord grip and butt
splices for wiring connections.
• Provided with security holes that fit
a padlock to prevent unauthorized
access into the riser pipe.
TSP-KV4 Hydrostatic Sensor Vented
Riser Cap Installation Kit
Replacement vented installation kit for use with the TSP-HIS or TSP-HIS XL sensor installed in
a 4" reservoir opening on double wall fiberglass tanks. One TSP-KV4 is already included with
each TSP-HIS or TSP-HIS-XL.
Model
TSP-KV4
Fuel Management Systems
Advantages
Description
Interstitial sensor riser cap kit for 2" riser pipes
Description
Hydrostatic sensor vented riser cap kit for 4" riser pipes
41
Probes and Sensors
TSP-KW4 Interstitial/Monitoring
Well Pipe Cap Installation Kit
Installation kit for installing sensors in a dry tank interstitial or monitoring well with a
4" riser.
Advantages
• The interstitial/monitoring well cap
is compression-fit into the riser pipe
via the use of a lever.
• Supplied with a cord grip and butt
splices for wiring connections.
• Provided with security holes that fit
a padlock to prevent unauthorized
access into the riser pipe.
Model
TSP-KW4
Fuel Management Systems
42
Description
Interstitial/monitoring well pipe cap kit for 4" riser pipes
Probes and Sensors
Advantages
• Easily customized to fit virtually
any sump by cutting the Uni-Strut®
assembly to desired length.
• Provided with 2", 3" and 4" pipe
clamps for mounting to sump piping.
Sensor Installation Accessories
Uni-Strut® Mounting Kit
Installation kit for installing the TSP-DDS and TSP-DTS in sump space.
Model
TSP-KS
Description
Uni-Strut® mounting kit for TSP-DDS and TSP-DTS sensors
• Sensor location easily adjusted by
the unique sliding feature of the
Uni-Strut® assembly.
Sensor Installation Accessories
Fuel Management Systems
Part Number
Description
TSP-DB1
One direct burial splice connector kit
TSP-DB10
Pack of 10 direct burial splice connector kits
TSP-DBTOOL
Epoxy dispensing tool
TSP-KW30
Pack of 30 3M splice connectors
Notes: 1. Use the TSP-DB1 or TSP-DB10 for direct burial cable applications or when weatherproof
junction boxes are not used.
2. The DBTOOL is required to dispense the epoxy.
3. Each direct burial splice connector kit includes a receptacle, three splice connectors and epoxy
for the dispensing tool.
43
External Console Hardware
TS-RA1 Remote Audible and Visible
Alarm Unit
The TS-RA1 is a remote audible and visible alarm unit for use with Franklin Fueling Systems
Automatic Tank Gauges.. The unit may be used as an overfill alarm as required by federal,
state and local regulations, or as a general purpose remote alarm annunciator.
Advantages
• Pulsating light and piezoelectric
buzzer warn of alarm conditions.
• Can be combined with TS-RK
remote acknowledge unit to provide
choice of alarm silencing options.
• Can be programmed through
Franklin Fueling Systems Automatic
Tank Gauges to activate in response
to any type of alarm in the system.
• Alarms for overfill and
general purpose.
Installation
• Install within 1000 feet of console.
• Wiring: Type THHN, TFFN or
THWN, 18 AWG or larger installed
in conduits and completely separated
from probe and sensor circuits.
• Operates directly from 110 VAC
line power.
• For use in indoor/outdoor
applications that have low
background noise.
Model
TS-RA1
TS-RK
Fuel Management Systems
44
Description
Standard intensity, tank overfill alarm with light and horn
Remote tank overfill alarm acknowledge unit
External Console Hardware
Advantages
• Pulsating light and electromechanical
buzzer warn of alarm conditions.
• Ideal for outdoor applications where
a high intensity alarm is necessary.
• Can be combined with TS-RK
remote acknowledge schemes.
TS-RA2 Remote Audible and Visible
Alarm Unit
The TS-RA2 is a high intensity remote audible and visible alarm unit for use with Franklin
Fueling Systems Automatic Tank Gauges.. The unit may be used as an overfill alarm as
required by federal, state and local regulations, or as a general purpose remote alarm
annunciator.
• Has adjustable sound level with
useful range of over 200 feet.
Installation
• Install within 1000 feet of console.
• Wiring: Type THHN, TFFN or
THWN, 18 AWG or larger installed
in conduits and completely separated
from probe and sensor circuits.
• Operates directly from 110 VAC
line power.
• For use in indoor/outdoor
applications that have high
background noise.
Description
High intensity, tank overfill alarm with light and horn
Remote tank overfill alarm acknowledge unit
Fuel Management Systems
Model
TS-RA2
TS-RK
45
External Console Hardware
TS-RK Remote Alarm
Acknowledge Unit
The TS-RK is a remote alarm acknowledge unit for use with all Franklin Fueling Systems
Automatic Tank Gauges equipped with remote alarm annunciators.
Advantages
• Locks or silences audible and visible
alarms up to 1000 feet.
• Facilitates rapid response during
emergencies in either indoor or
outdoor locations.
• Can be combined with TS-RA1
or TS-RA2 remote alarm units
to provide a choice of alarm
silencing options.
• Housed in rugged, nonmetallic
NEMA 4X unit ideal for any
weather condition.
Installation
• Install within 1000 feet of console.
• Wiring: Type THHN, TFFN or
THWN, 18 AWG or larger installed
in conduits and completely separated
from probe and sensor circuits.
• In conjunction with TS-RA1 or
TS-RA2 and operates directly from
110 VAC line power.
Model
TS-RK
Fuel Management Systems
46
Description
Remote tank overfill alarm acknowledge unit
External Console Hardware
Advantages
• Easy to use and install.
• Compatible with most
manufacturer’s dispensers.
TS-DIM Dispenser Interface Module
INCON’s Tank Sentinel® console and TS-DIM together offer the ultimate solution for
automating the inventory reconciliation process. Availabe as an internal module on fuel
management system consoles, not available on the TS-750 or Colibri.
• Gathers all relevant
dispensing information.
• Allows remote reconciliation.
Specifications
Applications
INCON’s dispenser interface module
(TS-DIM) connects to the manufacturer’s
dispenser distribution box to collect
dispensing data. The Tank Sentinel® console
gathers all relevant dispensing information.
• Collects information from the dispenser via
the distribution box.
• Eliminates the need to manually read
dispenser meters and stick tanks to
reconcile inventory.
• Provides everything required to automate
the reconciliation process.
• Directly connects to the Tank Sentinel®
console via a 3-wire RS 485 protocol
interface to all major dispenser
manufacturers including Tokheim, Gilbarco,
Dresser Wayne and Schlumberger.
• Available on fuel management system
consoles where disperser configuration
require a second DIM.
Capabilities
The TS-DIM collects information on all
dispensed product and consolidates the data
to a concise, easy-to-read format, facilitating
the inventory reconciliation process.
• Allows the ATG console to gather all
relevant dispensing information.
• Calculates the quantity of product
dispensed from each fueling point.
• Monitors up to 64 fueling points.
• Tracks the exact amount of product
dispensed even during fuel deliveries.
• Reliable operation and complete
data gathering ensures accurate
dispenser readings.
Fuel Management Systems
• Power: 110 VAC 20 Watts.
• Size: 8-1/2" × 7-1/2" × 2".
• Environment: 35 °F to 120 °F,
10-90 non-condensing humidity.
• Electrical: 115 VAC 60 Hz, 20 Watts,
dedicated circuit with earth ground.
47
External Console Hardware
Model
TS-DIM/G
TS-DIM/GS
TS-DIM/M
TS-DIM/S
TS-DIM/T
TS-DIM/W
Description
Dispenser interface module/Gilbarco dispensers
Dispenser interface module/G-site controller
Dispenser interface module/Mechanical dispensers
Dispenser interface module/Schlumberger dispensers
Dispenser interface module/Tokheim dispensers
Dispenser interface module/Wayne dispensers
2.00"
7.50"
8.50"
TS-DIM
Note: Not available with the TS-750 or Colibri consoles.
TS-DIM
TS-DIM Installation
4 MOUNTING HOLES
FOR #8 SCREWS
POINT OF SALE
DISPENSER
DISTRIBUTION
BOX
TS-DIM
TANK
TANK SENTINEL®
CONSOLE
Fuel Management Systems
48
External Console Hardware
Advantages
• In dual storage tank installations
where two submersibles are used
for one product grade with a single
line, the ATG will always start the
pump in the tank with the highest
product level.
• INCON ATG can be programmed to
respond to faults in the submersible
pumping system.
TS-TPI Turbine Pump Interface
The TS-TPI turbine pump interface provides a communication link for FE Petro intelligent
pump controllers to communicate faults to enabled devices. This link allows the INCON
ATG to include the reporting of submersible pump conditions to a monitoring party or to
the station operator. Also, by integrating the intelligence of these two systems, the ATG can
keep the station pumping fuel without service calls during several events that normally would
result in down time and lost fuel sales. The TS-TPI is a standard internal option on the fuel
management system consoles, not available on the TS-750 or Colibri.
• Automatic reset of the dry
running fault in the submersible
pump controller.
• Disables the submersible pump in
the event of high water levels.
• Remote monitoring of the entire
fueling system.
• Communication of pump diagnostic
faults to remote monitoring party.
• Standalone TS-TPI can be mounted
in a location convenient to
on-site personnel.
• In one product grade dual tank
installations with two submersible
pumps discharging into a single
discharge line, the second pump
starts directly upon the shutdown
of the first upon any shutdown
fault. Within moments, the fault is
reported to the monitoring party.
Configurations
TS-TPI integrated into TS-LS300 AutoLearn™
line leak detection console.
• INCON TS-1001 or TS-2001 ATG console
with version 3.5 software or higher.
• INCON TS-LS300 line leak
detection console.
• FE Petro smart controller model STP-SCI,
STP-SCIII or MagVFC™.
• For remote communication capabilities,
System Sentinel™ version 3.1 software or
higher or System Sentinel AnyWare™
version 1.0 or higher.
For TS-TPI standalone option,
• INCON TS-1001 or TS-2001 ATG console
with version 3.5 software or higher.
• TS-TPI module.
• FE Petro smart controller model STP-SCI,
STP-SCIII or MagVFC™.
• For remote communication capabilities,
System Sentinel™ version 3.1 software or
higher, or System Sentinel AnyWare™
version 1.0 or higher.
• Standalone: TS-TPI turbine pump
interface module.
• Included in AutoLearn™ TS-LS300:
TS-TPI turbine pump interface module
included in all TS-LS300 AutoLearn™ line
leak detectors.
Model
TS-TPI
Fuel Management Systems
System Requirements
Description
Turbine pump interface
Note: Not available with the TS-750.
49
External Console Hardware
TS-ROM2 BriteBox™ Relay
Output Module
The TS-ROM2 relay output module is a BriteBox™ expansion control module which may
be used with the Tank Sentinel® console to perform control functions in response to alarm
conditions. Not available on TS-750, fuel management system, or Colibri consoles.
Advantages
• Designed for use with the Tank
Sentinel® console to perform key
emergency functions, disable
pumps, operate indicator lights,
sound alarms and perform other
control functions.
• Flexible configuration that
energizes or de-energizes each
channel’s relay in response to an
alarm or loss of power.
• Available in 4 and 8
channel configurations.
• Uses miniature electromechanical
relays to switch external loads.
• Each TS-ROM2 output channel can
switch a 3 Amp 120/240 VAC load.
Installation
• Originally installed with Tank
Sentinel® consoles, or can be
added later.
• BriteBox™ mounted no further than
18" from Tank Sentinel® console.
Model
Description
TS-ROM2/4
Relay output module, 4 channel SPST
TS-ROM2/8
Relay output module, 8 channel SPST
TS-KB
Installation kit
Notes: 1. Up to four BriteBoxes™ can be connected to the console (two TS-SEMs, one TS-ROM2 and one
TS-CIM1 can be connected).
2. One TS-ROM2 is typically used for positive pump shutdown when certain alarms occur.
3. Order one TS-KB install kit for each BriteBox™ (includes ribbon cable, flexible conduit
and fittings).
4. Not available on TS-750, fuel management system, or Colibri consoles.
Fuel Management Systems
50
• Wiring: ten conductor BriteBus™
ribbon cable run through ¾" flexible
or rigid conduit connecting Tank
Sentinel® console to BriteBox™
enclosure. TS-KB installation kit
recommended.
• Wiring from the load circuits
is connected to the field wiring
terminal strip in the TS-ROM2.
External Console Hardware
Theory of Operation
The TS-SEM is used in situations
where the internal sensor inputs,
standard with all Tank Sentinel®
consoles, are not sufficient to handle
the amount of sensors required for
the application. The TS-SEM is used
to expand the number of external
console sensor inputs by increments
of eight. A maximum of two TS-SEMs
can be connected to one Tank
Sentinel®. The sensor alarms in turn
can be used to perform such tasks
as turning off submersible pumps or
sound alarms.
The Tank Sentinel® communicates
with all BriteBox™ intelligent junction
expansion modules over the BriteBus™
serial interface. This expansion
interface uses a 10 conductor ribbon
cable to connect the Tank Sentinel® to
the TS-SEM. The console automatically
recognizes the BriteBox™ when
connected and activates sensor
control software features in the
system. A heartbeat LED is provided
in the TS-SEM that indicates the
TS-SEM and Tank Sentinel® are
communicating with each other.
TS-SEM BriteBox™ Sensor
Expansion Module
The TS-SEM is a sophisticated BriteBox™ sensor expansion module that works exclusively
with Tank Sentinel® and leak detection consoles. This allows the Tank Sentinel® to expand
its total number of sensor inputs by increments of eight. The TS-SEM is supplied with an 18"
ribbon cable used to connect it to the console. All sensor field wiring terminals are provided
within the BriteBox™ and appropriately labeled to simplify installation. Not available on TS750, fuel management system, or Colibri consoles.
Installation
• Alternatively, an optional TS-KB
installation kit is recommended to
simplify this connection. Sensor
wiring is connected to the field
wiring terminal strip in the TS-SEM.
Each TS-SEM can handle up to
eight INCON standard or
BriteSensor™ sensors.
Model
Description
TS-SEM
Sensor expansion module
TS-KB
Installation kit
Notes: 1. Up to four BriteBoxes™ can be connected to the console (two TS-SEMs, one TS-ROM and one
TS-CIM1 can be connected).
2. One or two BriteBoxes™ can expand the total number of leak detection sensors in the system
by another eight or sixteen sensors (I.S. inputs).
3. Order one TS-KB install kit for each BriteBox™ (includes ribbon cable, flexible conduit
and fittings).
4. Not available on TS-750, fuel management system, or Colibri consoles.
Fuel Management Systems
• The TS-SEM is mounted in a
convenient location no further
than 18" from the Tank Sentinel®
console. The BriteBus™ ribbon cable
runs through a 3/4" flexible or rigid
conduit to connect the console to
the BriteBox™ enclosure.
51
TS-M Modem
The TS-M high-speed modem for remote communication with the Tank Sentinel® console.
Advantages
• Features originate or auto-answer
capabilities as well as pulse and
touch-tone dialing.
• Pre-configured for use with all
Tank Sentinel® products.
• TS-M complies with the Bell 103
standard at 300 Baud, the Bell 212A
standard at 1200 Baud and the V.22
bis standard at 2400 Baud.
• Operates with any other modem
meeting these standards.
• Preset dip switches ensure proper
operation after a power loss.
Model
TS-M
TS-MLS
Fuel Management Systems
52
Description
Modem
Multi-port telephone line switching device
TS-M Kit Includes
• Modem.
• Power adapter.
• Telephone cord with RJ11 connectors.
• M/F 25 pin/socket connector, RS232
communications cable.
• DB25 female to DB9 female adapter.
External Console Hardware
TS-EPS Ethernet Port Server
The TS-EPS is a serial to Ethernet converter that allows Tank Sentinel® consoles to be
assigned an IP address.
Model
TS-EPS
TS-EPS-N
Description
Ethernet port enabling device for Tank Sentinel® consoles
Ethernet port enabling device with null modem cable for other ATG systems. Not
required with fuel management system or Colibri consoles.
Note: The Ethernet port device allows remote access to tank gauge console through an
Ethernet IP address.
External Console Hardware Accessory
Waterproof Enclosure
(not available on fuel management system consoles)
Description
NEMA 4 waterproof enclosure
Fuel Management Systems
Part Number
TS-NEMA4X
53
Software
System Sentinel™ Remote Fuel
Management Software
System Sentinel™ is a powerful, versatile and easy-to-use remote fuel management software
that can communicate with all major tank gauge brands.
Advantages
• Broad communication
capabilities via modem, local or
wide area networks, satellites,
DSL, cable or other high-speed
internet-based methods.
• Gathers specified data in a
user-defined polling schedule or
in real-time.
• Provides summarized or detailed
information about all fueling sites.
• Deliveries are forecast from current
inventory usage rates.
• Collects dispensing data to allow
real-time reconciliation of sales data.
• Provides centralized control of all
compliance information such as tank
and line leak testing data and leak
detection sensor status.
• A wide variety of reports can be
custom-scheduled, displayed and
printed or faxed at specific times.
Specifications
• Microsoft Windows: 2000 or XP
Professional editions, or Windows NT 2.0
or Windows 98.
• Pentium class processor: 33 MHz minimum.
• Minimum of 50 MB available hard
drive space.
• Minimum of 32 MB RAM, 64 MB RAM with
Windows XP.
• Display setting of 800 × 600 pixels with
small font setting.
• Modem, Ethernet or serial connection.
Applications
Fuel Management Systems
With its easy-to-use report interface, System
Sentinel™ allows you to spend more time
managing your business. System Sentinel™
generates a wide variety of reports that can
be customized to meet your business needs.
The report formats are easy to read and
allow you to extract relevant data quickly
and easily for intelligent decision making.
Some available reports are:
• Alarm history.
• Delivery.
• Leak test detail.
• Tank test detail.
• Detail and summary inventory.
• Monthly, daily and shift reconciliation.
• Alarm status.
• Average daily usage.
• Cathodic protection.
• Regulatory with sensor status.
54
Capabilities
• Allows remote access to all fueling sites
24 hours a day.
• Inventory can be monitored as needed to
precisely schedule deliveries.
• Monthly reconciliation and reconciliation
summary reports allow for adjustments in
delivery or sales volume data.
• Can monitor and report effectiveness of
cathodic anti-corrosion devices.
• Communicates with all major tank
gauge brands, no need to replace existing
tank gauges.
• Displays data, highlights
trouble spots and facilitates
management by exception.
• Supports an unlimited number
of sites.
• Offers immediate notification of
alarms for corrective action.
Software
System Sentinel™ Interactive Tool Bar
System Sentinel™’s interactive tool bar lets you access your site data with a click of the mouse. Each of the icons
represents an important module of System Sentinel™.
1
Number
1
2
3
Module
Site Sentinel
Site Watch
Site Alert
4
Report Sentinel
5
Report Scheduler
6
Site Director
7
8
Database Administrator
Help
2
3
4
5
6
7
8
Description
Allows you to set-up and store the programming of tank gauges at your sites
Enables and assigns the polling function
Monitors your sites and notifies you when any alarms occur
Queries the database and organizes the information into user-selected reports or
data format
Allows you to schedule reports to be displayed, printed or faxed at predefined times
Provides a single-screen view of the alarm status up to 25 sites simultaneously, as well
as product usage, delivery forecasts and regulatory compliance status for management
by exception
Allows you to archive and/or purge the data in your database
Provides online assistance when using the software
System Sentinel™ Tech Edition
Fuel Management Systems
A cost effective version of System Sentinel that includes all the programming and diagnostic interface features used by
technicians. (Site Sentinel, Report Sentinel, Database Administrator)
55
Software
System Sentinel AnyWare™ Internet
Enabled Fuel Management Software
System Sentinel AnyWare™ is an internet based fuel management package designed to provide
you with unparalleled monitoring and control capabilities. Residing on a local server in your
home office, System Sentinel AnyWare™ will allow your personnel to access site information
through any web browser.
Advantages
• Broad communication capabilities via
modem, local or wide area networks,
satellites, DSL, cable or other
high-speed internet-based methods.
• Gathers specified data in a
user-defined polling schedule or
in real-time.
• Inventory can be monitored
as needed to precisely
schedule deliveries.
• Deliveries are forecast from current
inventory usage rates.
• Provides centralized control of all
compliance information such as tank
and line leak testing data and leak
detection sensor status.
• Access to information can be
controlled for multiple users.
• A wide variety of reports can be
custom-scheduled, displayed and
printed or faxed at specific times.
• Communicates with all major tank
gauge brands.
• Supports an unlimited number
of sites.
• Offers immediate notification of
alarms for corrective action.
Fuel Management Systems
56
Specifications
Capabilities
• Server:
Microsoft Windows server
operating system.
933 MHz Pentium III with 512 MB of
physical memory.
100 MB for the application and 500 MB to
1 GB for the database disk space.
Second processor will boost
performance significantly.
• Third Party application:
Microsoft Internet Server (IIS) web server.
Microsoft SQL server.
Seagate Crystal Reports server.
• The powerful rules engine of the System
Sentinel AnyWare™ allows you to manage by
exception by automatically forwarding
alarm, leak test and inventory information
to the appropriate people when immediate
attention is required.
• Capable of communicating to an unlimited
number of sites using your WAN (wide
area network) or a bank of multiple
modems. System Sentinel AnyWare™ will
quickly collect your site information and
get it to you to help you run your business.
Software
Advantages
• E-mails or text messages are
immediately sent upon receipt of an
alarm notification from the console
to help lower service costs, provide
less downtime and help have a
higher throughput.
• Automatically and reliably retrieves
fuel management and compliance
data from all sites to eliminate
reporting errors, lost printouts and
keep all data in one place. This frees
up site personnel for other tasks.
Get Connected AnyWare™ Remote
Polling Service
Get Connected AnyWare™ is a remote polling service from Franklin Fueling Systems that
allows customers internet access to their sites from any web browser. Get Connected
AnyWare™ acts as an application service provider of our powerful System Sentinel AnyWare™
software, allowing customers access to the application running on our servers at the Get
Connected Data Center. Through high speed Ethernet or modem dial-up communications,
Get Connected AnyWare™ can communicate with ATGs and retrieve important fuel
management, alarm and compliance data.
Site can be accessed at www.gcanyware.com. Log in using the user demo and password demo.
• Hardware and software is maintained
by FFS so there is no need to
purchase, install or maintain a server
to monitor your sites.
• Secure access to site data from
anywhere so you can view data
with immediate accuracy from your
home, office or the road.
• Daily usage and delivery forecast
tools help to accurately schedule fuel
drops and eliminate running out.
• Centralized, secure compliance
information makes all your sites
accessible in minutes.
One poll
Two polls
Three polls
On-demand
Polling Options
AM, All history poll
PM, Alarms, inventory and latest delivery
Late PM, Alarms, inventory and latest delivery
Customer directed polling any time
Fuel Management Systems
• A wide variety of reports and date
range options help generate
various compliance, alarm and
inventory reports.
57
Software
Get Connected AnyWare™ Remote
Polling Service
Monthly Fee Schedule per Site
ATG Type
Connection type
Up to three polls daily
Data export service
Data archive service
INCON/EBW
Modem
High speed
$30.00
$20.00
$50/month per customer
$250 one time fee
Veeder-Root/Gilbarco
Modem
High speed
$40.00
$30.00
Limited Time Incentive
Customers who use all Franklin Fueling System products at a new site will receive two years
of Get Connected AnyWare™ service for that site at no cost. Customers who replace a
competitive ATG system with an INCON TS-5 Series console will receive two years of the
Get Connected AnyWare™ service for that site at no cost.
Polling Service Details
Get Connected AnyWare™ hosts the server, the application (System Sentinel AnyWare™) and
provides internet access to it. Online training and phone/e-mail support are available. Other
details include:
• Ability to browse to the Get Connected AnyWare™ Web site from home, office, on the road
or anywhere you have internet access.
• Customers can monitor their own sites and respond to alarms, compliance issues and
perform fuel management.
• Rules can be created to send out e-mails and text messages on alarms and other events.
• All sites will be polled at least once daily and more frequent polling options are available.
• Get Connected AnyWare™ consists of an auto-renewing six month agreement that can be
discontinued at any time with a 30-day notice.
Fuel Management Systems
58
Software
Receiving for High Speed Connections
Customers with an Ethernet connection can program their ATGs to contact Get Connected AnyWare™ on various
alarms or events. Get Connected AnyWare™ will receive these transmissions and poll the site for new data. The new
data will be applied to the current rules and e-mails will be generated if applicable.
Support While Getting Connected
Franklin Fueling Systems will provide support in bringing online and troubleshooting communication with sites using
Franklin Fueling Systems communications equipment. This includes the TS-EPS Ethernet port server, the TS-MLS
multi-line phone switch and the TS-FM2 internal modem.
Site Survey
If requested, Franklin Fueling Systems will recommend a distributor or service company in the customer’s area to
perform site surveys of the sites they wish to bring online.
More Functions
Fuel Management Systems
Get Connected AnyWare™ will support connectivity to the following ATGs:
• INCON TS-5 Series (TS-5, TS-550, TS-5000, TS-EMS).
• INCON TS-1001 Series (TS-1001, TS-2001, TS-504, TS-508, TS-750).
• EBW Autostik (Bulkstik and Autostik Jr. version 3.905 or greater).
• Veeder-Root TLS-300, 350 and Gilbarco EMC Automatic Tank Gauges.
Connection can be established via Ethernet or internal modem. The Get Connected AnyWare™ data center will store
two years worth of data for each site and allow you to export your data. Data older than two years can be accessed
with the data archive service.
59
Accessories
Sump Test System Kit
The TS-STS sump test system is designed specifically to test dispenser and turbine
containment sumps for leaks. Up to four sumps can be leak-tested simultaneously with
accurate compliance test results available in just 15 minutes. The system consists of two
carrying cases containing a TS-STS console and quick start guide in one, and leak test probes,
cables and printer paper in the other.
Advantages
• Designed to deliver cost-effective
environmental compliance test data.
• Easily transported in two supplied
carrying cases.
• Easily set-up and programmed
with site-specific data and sump
identification before a test. Site
and test data can also be saved to a
laptop database.
• Laptop interface optional using
System Sentinel™ Tech Software.
• Accommodates up to four probes
for testing of up to four dispensers
or four turbine containment sumps
simultaneously.
• Uses INCON’s magnetostrictive
probe technology for unparalleled
accuracy and reliable results.
• Highly accurate leak test detects
level changes greater than 0.002
inches during the fifteen minute test.
• Provides accurate test solution levels
for each sump monitored.
• Automatically prints out passed
and/or failed sump leak test reports
in just fifteen minutes after starting a
leak test. Printer included.
• Shows the date and time of the test,
test-solution levels and the leak test
results on sump leak test reports.
• Additional sump leak test reports
can also be printed at the console
before other tests are completed.
Fuel Management Systems
60
Accessories
• Operating temperature:
Console - 32° to 122 °F
(0° to 50 °C).
Leak test probes - -40° to 140 °F
(-40° to 60 °C).
• Storage temperature:
Console - -4° to 140 °F
(-20° to 60° C).
Leak test probes - -40° to 158 °F
(-40° to 70 °C).
• Intrinsic safety rating:
Leak test probes - Class 1, Div. 1,
Group D.
• Carry case weight and dimensions:
Console - 33 lbs. (15 kg), 24" × 19" ×
8½" (62 cm × 49 cm × 22 cm).
Leak test probes - 30 lbs. (13.5 kg),
38" × 18" × 6" (97 cm × 45 cm × 16 cm).
Model
TS-STS-2K
TS-STS-3K
TS-STS-4K
• Number of sumps monitored:
Console - 4.
Leak test probes - 1.
• Applicable liquids:
Leak test probes - testing solution.
• Level units:
Console - inches.
• Display type and size:
Console - alphanumeric LCD,
2 lines of 40 characters.
• Printer type:
Console - 24 column thermal printer.
• Power requirements:
Console - 115 VAC, 50 Watts,
6' power cord with 3 prong
plug supplied.
Leak test probes - 50' cable supplied.
Description
Sump test system with two probes
Sump test system with three probes
Sump test system with four probes
FLAT METAL
OR ANGLE
IRON
REQUIRED
GROUNDED
115 VAC
POWER
CORD
TS-STS
CONSOLE
LEAK TEST PROBE
TEST
SOLUTION
(LEVEL
ABOVE
OPENINGS)
Fuel Management Systems
Specifications
61
Spare Parts
TS-5, TS-550, TS-5000 and TS-EMS Consoles
Part Number
TSSP-CM
TSSP-CM/EMS
TSSP-CM/R
TSA-CMUPG
TSSP-10ARLY
TSSP-2WSNS
TSSP-3WSNS
TSSP-420IB
TSSP-420EXP
TSSP-ACI
TSSP-IO
TSSP-PRB
TSSP-RLY
TSP-ENCD
TSSP-IFB5
TSSP-IFB5X
TSSP-IPPTR
TSSP-LCD
TSSP-PS
TSSP-SP5FUSE
TSSP-T5MB
TSSP-T550MB
TSSP-T5000MB
TSSP-TRMBLK
Description
Spare controller module, fuel management system application only, no software options
Spare controller module for TS-EMS, vapor recovery monitoring application only
Replacement controller module, factory programmed with required options
Upgrade kit for TSSP-CM in stock to add original options
Spare 6 output 10 amp relay module
Spare 12 input 2-wire sensor module
Spare 8 input 3-wire sensor module
Spare 8 input 4-20ma module
Spare 8 input EXP 4-20ma module
Spare 12 input AC input module
Spare input output module
Spare 12 input probe module
Spare 8 output relay module
Replacement encoder for TS-VFM
TS-5 interface board
TS-550, TS-5000 and TS-EMS interface board
Impact printer assembly
LCD display
Power supply module
Spare Fuse Kit
TS-5 motherboard
TS-550 and TS-EMS motherboard
TS-5000 motherboard
Package of 10 assorted terminal blocks
Note: The serial number of the old CM must be provided when ordering the TSSP-CM/R. Provide the serial number of the old and
new CM when ordering the TSA-CMUPG.
TS-504 and TS-750 Consoles
Part Number
TSSP-BAT
TSSP-DSP1
TSSP-DSPKC1
TSSP-ENCLK
TSSP-MSB4
TSSP-PSTB4
TSSP-PSTB4-SM
TSSP-PTR
TSSP-PTRC1
TSSP-SMSB4
TSSP-SPFUSE
TSSP-SVKT4-SM
VSSP-MSB4
VSSP-SMSB4
Description
3 Volt lithium battery
Keypad/display PC board
Display/keypad cable
Enclosure lock and key
Main system PC board, 110 VAC
Probe sensor terminal board
Surface mount probe/sensor terminal board, serial numbers 100000 and higher
Printer assembly
Printer cable
Surface mount system PC board, 110 VAC, serial numbers 100000 and higher
Spare fuse kit
TS-504 and TS-750 service kit for surface mount boards*
Main system PC board, 220 VAC
Surface mount system PC board, 220 VAC, serial numbers 100000 and higher
TSSP-SVKT4-SM includes one of the following: TSSP-SMSB4, TSSP-DSP1, TSSP-PSTB4-SM, TSSP-PTR, TSSP-PTRC1, TSSP-DSPKC1,
TSSP-SPFUSE, TSSP-ENCLK and TSSP-BAT.
*
Fuel Management Systems
TS-508 Console
Part Number
TSSP-BAT
TSSP-DSP1
TSSP-DSPKC1
TSSP-ENCLK
TSSP-MSB8
TSSP-PSTB8
TSSP-PSTB8-SM
TSSP-PTR
TSSP-PTRC1
TSSP-SMSB8
TSSP-SPFUSE
TSSP-SVKT8-SM
VSSP-MSB8
VSSP-SMSB8
Description
3 Volt lithium battery
Keypad/display PC board
Display/keypad cable
Enclosure lock and key
Main system PC board, 110 VAC
Probe sensor terminal board
Surface mount probe/sensor terminal board, serial numbers 100000 and higher
Printer assembly
Printer cable
Surface mount system PC board, 110 VAC, serial numbers 100000 and higher
Spare fuse kit
TS-508 service kit for surface mount boards*
Main system PC board, 220 VAC
Surface mount system PC board, 220 VAC, serial numbers 100000 and higher
TSSP-SVKT8-SM includes one of the following: TSSP-SMSB8, TSSP-DSP1, TSSP-PSTB8-SM, TSSP-PTR, TSSP-PTRC1, TSSP-DSPKC1,
TSSP-SPFUSE, TSSP-ENCLK and TSSP-BAT.
*
62
Spare Parts
TS-1001 Console
Part Number
TSSP-BAT
TSSP-DSP1
TSSP-DSPKC1
TSSP-ENCLK
TSSP-MSB1
TSSP-PSTB1
TSSP-PSTB1-SM
TSSP-PTR
TSSP-PTRC1
TSSP-SMSB4
TSSP-SPFUSE
TSSP-SVKT1-SM
TSSP-T1KEY
VSSP-MSB1
VSSP-SMSB4
Description
3 Volt lithium battery
Keypad/display PC board
Display/keypad cable
Enclosure lock and key
Main system PC board, 110 VAC
Probe sensor terminal board
Surface mount probe/sensor terminal board, serial numbers 100000 and higher
Printer assembly
Printer cable
Surface mount system PC board, 110 VAC, serial numbers 100000 and higher
Spare fuse kit
TS-1001 service kit for surface mount boards
Replacement key
Main system PC board, 220 VAC
Surface mount system PC board, 220 VAC, serial numbers 100000 and higher
TSSP-SVKT1-SM includes one of the following: TSSP-SMSB4, TSSP-DSP1, TSSP-PSTB1-SM, TSSP-PTR, TSSP-PTRC1, TSSP-DSPKC1,
TSSP-SPFUSE, TSSP-ENCLK and TSSP-BAT.
*
TS-2001 Console
Part Number
Description
TSSP-BAT
3 Volt lithium battery
TSSP-DSP2
Keypad/display PC board
TSSP-DSPKC2
Display/keypad cable
TSSP-ENCLK
Enclosure lock and key
TSSP-MSB2
Main system PC board, 110 VAC
TSSP-PSTB2
Probe sensor terminal board
TSSP-PSTB2-SM Surface mount probe/sensor terminal board, serial numbers 100000 and higher
TSSP-PTR
Printer assembly
TSSP-PTRC2
Printer cable
TSSP-SMSB8
Surface mount system PC board, 110 VAC, serial numbers 100000 and higher
TSSP-SPFUSE
Spare fuse kit
TSSP-SVKT2-SM TS-2001 service kit for surface mount boards*
VSSP-MSB2
Main system PC board, 220 VAC
VSSP-SMSB4
Surface mount system PC board, 220 VAC, serial numbers 100000 and higher
*
TSSP-SVKT2-SM includes one of the following: TSSP-SMSB8, TSSP-DSP2, TSSP-PSTB2-SM, TSSP-PTR, TSSP-PTRC2, TSSP-DSPKC2,
TSSP-SPFUSE, TSSP-ENCLK and TSSP-BAT.
Part Number
010-0072
020-1503
430-0010
TS-CU
TS-FC
TS-FPU
TS-LSU
Fuel Management Systems
TS-LLD
Description
Control unit terminal interface board
Hardware kit
0.5 Amp fuse
Control unit
Line filter capacitor
Face plate unit
Leak sensor unit
63
Spare Parts
TS-LS300
Part Number
600-0080
TS-ALCAL
TS-ALFUSE
TS-AFALNIP
TS-ALNIP
TS-LSU300
TS-LSU300E
TSSP-ALDB2
TSSP-ALDB4
TSSP-ALMB2
TSSP-ALMB2E
TSSP-ALMB4
TSSP-ALMB4E
TSSP-ALPTRC
TSSP-ALTPI
VSSP-ALMB2
VSSP-ALMB4
Description
Transducer quick disconnect cable
3.0 gph calibration kit
AutoLearn™ fuse kit
Alternative fuels needle valve kit
Needle valve kit
Intrinsically safe pressure transducer
Explosion proof pressure transducer
2-line display board
4-line display board
2-line intrinsically safe main board, 110 VAC
2-line explosion proof main board, 110 VAC
4-line intrinsically safe main board 110 VAC
4-line explosion proof main board 110 VAC
Ribbon cable, display board to main board
TPI turbine pump interface board
2-line I/S main board, 220 VAC
4-line I/S main board, 220 VAC
TS-LS500
Part Number
600-0080
TS-ALCAL
TS-AFALNIP
TS-ALNIP
TS-LSU500
TS-LSU500E
Description
Transducer quick disconnect cable
3.0 gph calibration kit
Alternative fuels needle valve kit
Needle and valve kit
Intrinsically safe 4-20 mA pressure transducer
Explosion proof 4-20 mA pressure transducer
TS-STS Sump Test Kit
Fuel Management Systems
Part Number
Description
282-0027
Chain, including split ring
282-0058
Split ring
600-0200
Probe cable 50'
TS-PRB-1
12" leak test probe kit*
TS-TP2
One box of 5 rolls of thermal printer paper
TSP-SSP
Stainless steel probe float
STS-CASE
STS probe case
STS-PRB-12
12" leak test probe
STS-REPAIR
STS system repair
Note: For parts for the TS-STS unit itself, reference the TS-1001 parts list. Repair price includes labor and return shipping only.
*
Probe kit includes probe, float, chain and cable.
Accessories
Part Number
430-0033
3 amp fuse for TS-ROM2/4 or /8
64
Description
NS
T
TIO
Y
O
R
US
SO
L
U
U C N T
A
Distributed by:
3760 Marsh Road • Madison, Wisconsin 53718, USA
Tel: +1 608 838 8786 • Fax: +1 608 838 6433
Tel: USA & Canada 1 800 225 9787
Tel: México 001 800 738 7610
www.franklinfueling.com
FFS-0060 01-10