SGI® Rackable™ H2106-G7 System User`s Guide

SGI® Rackable™ H2106-G7 System User`s Guide
SGI® Rackable™ H2106-G7
System User’s Guide
007-5683-001
COPYRIGHT
© 2010 SGI. All rights reserved; provided portions may be copyright in third parties, as indicated elsewhere herein. No permission is granted to copy, distribute,
or create derivative works from the contents of this electronic documentation in any manner, in whole or in part, without the prior written permission of SGI.
LIMITED RIGHTS LEGEND
The software described in this document is “commercial computer software” provided with restricted rights (except as to included open/free source) as specified
in the FAR 52.227-19 and/or the DFAR 227.7202, or successive sections. Use beyond license provisions is a violation of worldwide intellectual property laws,
treaties and conventions. This document is provided with limited rights as defined in 52.227-14.
The electronic (software) version of this document was developed at private expense; if acquired under an agreement with the USA government or any
contractor thereto, it is acquired as “commercial computer software” subject to the provisions of its applicable license agreement, as specified in (a) 48 CFR
12.212 of the FAR; or, if acquired for Department of Defense units, (b) 48 CFR 227-7202 of the DoD FAR Supplement; or sections succeeding thereto.
Contractor/manufacturer is SGI, 1140 E. Arques Avenue, Sunnyvale, CA 94085.
TRADEMARKS AND ATTRIBUTIONS
SGI, and the SGI logo are registered trademarks and Rackable is a trademark of Silicon Graphics International in the United States and/or other countries
worldwide.
AMD is a registered trademark and Opteron is a trademark of Advanced Micro Devices, Inc.
Fusion-MPT, Integrated RAID, MegaRAID, and LSI Logic are trademarks or registered trademarks of LSI Logic Corporation.
HyperTransport is a licensed trademark of the HyperTransport Technology Consortium.
InfiniBand is a registered trademark of the InfiniBand Trade Association.
Intel, Itanium, and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
Internet Explorer and MS-DOS are registered trademarks of Microsoft Corporation.
Java and Java Virtual Machine are trademarks or registered trademarks of Sun Microsystems, Inc.
Linux is a registered trademark of Linus Torvalds, used with permission by SGI.
Novell and Novell Netware are registered trademarks of Novell Inc.
PCIe and PCI-X are registered trademarks of PCI SIG.
Phoenix and PhoenixBIOS are registered trademarks of Phoenix Technologies Ltd.
Red Hat and all Red Hat-based trademarks are trademarks or registered trademarks of Red Hat, Inc. in the United States and other countries.
SUSE LINUX and the SUSE logo are registered trademarks of Novell, Inc.
UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company, Ltd.
All other trademarks mentioned herein are the property of their respective owners.
Adaptec, HostRAID, and the Adaptec logo are registered trademarks of Adaptec Inc.
Record of Revision
007-5683-001
Version
Description
001
October 2010
First release
iii
Contents
1
Introduction
.
.
.
Server Board Features .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
HyperTransport Interconnect .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
Memory .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
.
.
.
.
.
.
.
.
Serial ATA .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
SAS Support
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
PCI Expansion Slots
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
UIO .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
Onboard Controllers/Ports .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
Onboard Graphics Controller .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
Other Features .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
Server Chassis Features .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
System Power .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
Serial ATA and SAS Subsystems .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
Front Control Panel .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
Serverboard .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
6
Cooling System .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
6
Server Installation .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
Unpack the System .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
Prepare for Setup
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
Choose a Setup Location
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
Warnings and Precautions .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 10
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 10
Server Precautions .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 11
Rack Mounting Considerations .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 11
Ambient Operating Temperature .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 11
Rack Precautions
007-5683-001
.
.
Processors .
2
.
v
Contents
Reduced Airflow
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 11
Mechanical Loading .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 11
Circuit Overloading .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 12
Reliable Ground .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 12
Install the System into a Rack
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 12
Separate the Sections of the Rack Rails .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 12
Outer Rack Rails.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 13
Install the Outer Rails to the Rack .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 14
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 14
Install the Inner Rails .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 14
Install the Server in a Rack .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 15
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 16
Access the Inside of the Chassis.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 16
Check the CPUs (processors)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 18
Check the System Memory .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 18
Install Expansion PCIe Cards
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 18
Check all Cable Connections and Airflow .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 18
Check the Drive Bay Setup .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 18
Check the System Disk Drives .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 18
Check the Airflow .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 19
Supply Power to the System
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 19
System Interface.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 21
Overview .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 21
Control Panel Buttons
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 22
.
.
Control Panel LEDs .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 23
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 23
Overheat/Fan Fail
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 23
NIC1 .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 24
NIC2 .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 24
HDD .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 24
Power
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 25
Drive Carrier LEDs .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 25
Power Fail
vi
.
Install the Inner Rail Extension .
Check the Node Board Setup.
3
.
.
007-5683-001
Contents
4
5
System Safety .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 27
Electrical Safety Precautions
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 27
Serverboard Battery.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 28
DVD-ROM Laser .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 28
Mainboard Replaceable Soldered-in Fuses .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 28
General Safety Precautions .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 29
ESD Precautions.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 29
System Serverboard Information .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 31
.
.
.
Handling the Node Board
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 31
ESD Precautions
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 32
Unpacking .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 32
Connecting the Control Panel .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 32
.
Serverboard I/O Ports
007-5683-001
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 33
Serverboard Details .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 34
CPUs .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 34
Memory
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 34
Chipsets
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 34
Expansion Slots
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 34
PC Health Monitoring .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 35
ACPI Features .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 35
Onboard I/O
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 35
Serverboard Dimensions .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 36
.
Installing Memory .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 37
Install DIMMs .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 37
Memory Support .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 38
Memory DIMM Layout
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 39
Memory DIMM Rules .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 39
Hard Disk Drives (H2106-G7 Chassis) .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 40
Drive Configurations
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 41
PCIe Expansion Cards .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 42
Installing a PCIe Expansion Card .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 42
Power Supply Functional Rating
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 43
.
vii
Contents
6
Basic Troubleshooting and Chassis Service .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 45
Basic Troubleshooting Procedures .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 45
If the System Does Not Power Up .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 45
System Powers Up But Will Not Boot .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 46
No Video After System Power Up .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 46
Memory Errors .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 46
Chassis Service Information .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 47
Static-Sensitive Devices .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 47
Precautions .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 47
Unpacking
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 48
Control Panel .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 48
System Fans .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 48
System Fan Failure .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 49
Replacing System Fans .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 50
Removing a Fan
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 50
Installing a New Fan
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 50
Drive Bay Installation/Removal .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 50
Accessing the Drive Bays
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 50
Disk Drive Installation .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 51
Mounting a Disk Drive in a Drive Carrier .
.
.
.
.
.
.
.
.
.
.
.
.
.
. 51
Installing/Removing Hot-swap Drives .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 52
Hard Drive Backplane .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 53
DVD-ROM Drive Installation .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 53
Accessing the Inside of the Chassis
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 53
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 54
Power Supply Failure
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 54
Removing/Replacing the Power Supply.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 54
Power Supply.
.
.
Removing the Power Supply
7
viii
BIOS .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 54
Installing a New Power Supply.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 54
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 55
Starting BIOS Setup Utility .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 55
How To Change the Configuration Data .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 56
Starting the Setup Utility .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 56
.
.
.
.
007-5683-001
Contents
Main Menu .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 57
System Time/System Date .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 57
CPU Configuration
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 57
CPU Information .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 57
Change Frequency and uCode Patch Level. .
.
.
.
.
.
.
.
.
.
.
.
.
. 57
GART Error Reporting
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 57
Microcode Update .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 58
.
Secure Virtual Machine Mode .
Power Now.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 58
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 58
ACPI SRAT Table .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 58
Clock Spread Spectrum
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 58
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 58
Onboard PCI IDE Controller .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 58
Primary/Secondary/Third IDE Master/Slave .
.
.
.
.
.
.
.
.
.
.
.
.
.
. 58
.
. 58
.
IDE Configuration .
.
LBA/Large Mode .
007-5683-001
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Block (Multi-Sector Transfer) .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 59
PIO Mode .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 59
DMA Mode
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 59
S.M.A.R.T..
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 59
32-Bit Data Transfer .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 59
Hard Disk Write Protect
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 60
IDE Detect Timeout (Sec) .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 60
ATA(PI) 80-Pin Cable Detection .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 60
SuperI/O Configuration.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 60
Serial 1 Address
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 60
Serial 2 Address
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 60
Serial Port Mode .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 60
Restore on AC Power Loss
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 61
Watch Dog Timer .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 61
Advanced ACPI Configuration .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 61
ACPI Version Features
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 61
.
.
ACPI APIC Support
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 61
AMI OEMB Table .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 61
ix
Contents
IPMI Configuration .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 61
View BMC System Event Log .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 61
Clear BMC System Event Log .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 62
Set LAN Configuration .
IP Address .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 62
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 62
MAC Address .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 62
Subnet Mask
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 62
Gateway Address
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 62
MPS Configuration .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 63
MPS Revision .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 63
PCI Express Configuration .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 63
Relaxed Ordering .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 63
Extended Tag Field .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 63
No Snoop
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 63
Active State Power Management .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 63
.
.
Extended Sync .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 63
Remote Access Configuration .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 64
Remote Access .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 64
Serial Port Number .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 64
Serial Port Mode
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 64
Flow Control
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 64
Redirection After BIOS POST .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 64
Terminal Type .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 64
VT-UTF8 Combo Key Support.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 64
Sredir Memory Display Delay .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 65
.
USB Configurations .
x
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 65
Legacy USB Support
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 65
USB 2.0 Controller Mode .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 65
BIOS EHCI Hand Off .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 65
Legacy USB1.1 HC Support
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 65
USB Mass Storage Device Configuration .
.
.
.
.
.
.
.
.
.
.
.
.
.
. 65
USB Mass Storage Reset Delay
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 65
Emulation Type .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 66
.
.
.
.
007-5683-001
Contents
System Health Monitor .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 66
CPU Overheat Temperature
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 66
System Fan Monitor
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 66
Fan Speed Control Modes .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 66
PCI/PNP Settings Menu
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 66
Clear NVRAM .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 66
Plug & Play O/S
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 67
PCI Latency Timer.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 67
Allocate IRQ to PCI VGA .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 67
Pallette Snooping .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 67
PCI IDE Busmaster
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 67
Offboard PCI/ISA IDE Card .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 67
IRQ3 ~ IRQ15 Settings
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 67
DMA Channel 0 ~ DMA Channel 7 Settings .
.
.
.
.
.
.
.
.
.
.
.
.
. 68
Reserved Memory Size
.
.
.
.
.
.
.
.
.
.
.
.
. 68
.
.
.
.
.
.
.
HotPlug Reserve I/O Port Size.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 68
HotPlug Reserve Memory Size
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 68
HotPlug Reserve PFMemory Size .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 68
Onboard NIC PXE Option ROM .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 68
BIOS Settings Configuration .
007-5683-001
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 68
Quick Boot .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 68
Quiet Boot .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 69
Add On ROM Display Mode .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 69
Bootup Num Lock .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 69
PS/2 Mouse Support
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 69
Wait for F1 if Error
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 69
Hit 'DEL' Message Display
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 69
Interrupt 19 Capture
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 69
Boot Device Priority .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 69
Hard Disk Drives .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 70
Removable Drives .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 70
CD/DVD Drives
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 70
Network Drives
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 70
xi
Contents
Security Settings Menu .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 70
Change Supervisor Password .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 70
Change User Password .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 70
.
.
Boot Sector Virus Protection
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 70
NorthBridge Configuration .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 71
Channel Interleaving
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 71
Enable Clock to All DIMMs
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 71
Memory Hole Remapping .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 71
CS Sparing Enable .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 71
Power Down Enable
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 71
Power Down Mode .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 71
.
DRAM Parity Enable .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 71
Bank Swizzle Mode
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 72
ECC Configurations .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 72
ECC Mode .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 72
DRAM ECC Enable
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 72
DRAM Scrub Redirect .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 72
4-Bit ECC Mode
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 72
DRAM BG Scrub .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 72
Data Cache BG Scrub .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 72
L2 Cache BG Scrub.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 73
L3 Cache BG Scrub.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 73
DRAM Timing Configurations .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 73
DRAM Timing Config .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 73
Memory Timing Parameters
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 73
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 73
SouthBridge Configuration .
A15 ECOs .
xii
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 73
Port 0 ~ Port 5 ESP .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 73
Dis #THRMTRIP before KBRst
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 73
SATA-IDE Ports Auto Clk Ctrl
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 74
SATA-AHCI Ports Auto Clk Ctrl .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 74
SATA Port 0 ~ Port 5 Mode
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 74
OHCI/EHCI HC Device Functions .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 74
.
007-5683-001
Contents
On Chip SATA Channel .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 74
On Chip SATA Type .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 74
SATA IDE Combined Mode .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 74
PATA Channel Configuration .
Power Saving Features.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 74
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 75
Port 02 ~ Port 13 Features .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 75
Gen 2 High Speed Mode .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 75
Link ASPM
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 75
Link Width .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 75
Slot Power Limit, W .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 75
Compliance Mode .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 75
Remap Port Device Number .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 76
L1 Immediate ACK
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 76
Lane Reversal .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 76
Hot Plug Support .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 76
NB-SB Port Features
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 76
NB-SB Link APSM
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 76
Link Width .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 76
NP NB-SB VC1 Traffic Support .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 76
Compliance Mode .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 76
GPP1 ~ GPP3b Core Settings .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 77
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 77
Powerdown Unused Lanes.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 77
Core Configuration
.
.
Turnoff Off PLL During L1/L23 .
TX Drive Strength .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 77
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 77
TXCLK Clock Gating in L1 .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 77
LCLK Clock Gating in L1 .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 77
SB Core Settings
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 77
TX Drive Strength .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 77
TXCLK Clock Gating in L1 .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 78
LCLK Clock Gating in L1 .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 78
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 78
Peer to Peer Among GPP1/GPP2 .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 78
Debug Options .
007-5683-001
.
.
.
.
.
xiii
Contents
Reset to Training Delay (ms) .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 78
Receiver Detection Pooling (ms) .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 78
Hide Unused PCIE P2P Bridges
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 78
GFX Card Workaround.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 78
Debug Bus Configuration
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 78
PCIE Debug Bus
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 78
Hyper Transport Configuration .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 79
HT Extended Address .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 79
HT3 Link Power State .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 79
Unit ID Clumping .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 79
HT Link Tristate
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 79
.
NB Deemphesis Level .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 79
IOMMU.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 79
Primary Video Controller .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 79
PCI Spread Spectrum .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 80
.
Debug Options .
xiv
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 80
Memory Decod on Sec. 6FX
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 80
IOC Peer-to-Peer Mode.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 80
Northbridge Interrupt Pin .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 80
Exit Menu .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 80
Save Changes and Exit .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 80
Discard Changes and Exit .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 80
Discard Changes
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 81
.
.
.
Load Optimal Defaults .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 81
Load Fail-Safe Defaults
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 81
.
.
.
A
BIOS Error Codes .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 83
B
System Operating and Regulatory Overview .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 85
Operating Environment .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 85
Regulatory Compliance .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. 85
007-5683-001
Figures
007-5683-001
Figure 1-1
Rackable H2106-G7 Server (Top Removed)
.
.
.
.
.
.
.
2
Figure 1-2
Processor and I/O Chipset System Block Diagram .
.
.
.
.
.
.
7
Figure 2-1
Separating and Installing the Rack Rails .
.
.
.
.
.
.
.
.
. 13
Figure 2-2
Installing the Server in a Rack
.
.
.
.
.
.
. 15
.
.
.
.
Figure 2-3
Accessing the Inside of the System .
.
.
.
.
.
.
.
.
.
. 17
Figure 3-1
System Front and Rear Interface Components .
.
.
.
.
.
.
. 21
Figure 3-2
System Reset Button .
.
.
.
.
.
.
.
.
.
.
.
.
.
. 22
Figure 3-3
System Power On Button
.
.
.
.
.
.
.
.
.
.
.
.
. 22
Figure 3-4
Power Fail LED .
.
.
.
.
.
.
.
.
.
.
.
.
.
. 23
Figure 3-5
Overheat/Fan Fail LED .
.
.
.
.
.
.
.
.
.
.
.
.
. 23
Figure 3-6
LAN1 Network Activity NIC1 LED .
.
.
.
.
.
.
.
.
.
. 24
Figure 3-7
LAN2 Network Activity NIC2 LED .
.
.
.
.
.
.
.
.
.
. 24
Figure 3-8
Hard Drive Activity LED
.
.
.
.
.
.
.
.
.
.
.
.
. 24
Figure 3-9
Power On LED .
.
.
.
.
.
.
.
.
.
.
.
.
. 25
Figure 4-1
Installing the Onboard Battery
.
.
.
.
.
.
.
.
.
.
.
. 28
Figure 5-1
Control Panel Header Pins
.
.
.
.
.
.
.
.
.
.
.
. 33
Figure 5-2
I/O Ports Locations .
.
.
.
.
.
.
.
.
.
.
.
.
.
. 33
Figure 5-3
Node Board Features .
.
.
.
.
.
.
.
.
.
.
.
.
.
. 36
Figure 5-4
DIMM Installation Example .
.
.
.
.
.
.
.
.
.
.
.
. 38
Figure 5-5
H2106-G7 Disk Drive Locations.
.
.
.
.
.
.
.
.
.
.
. 40
Figure 6-1
System Cooling Fan Locations .
.
.
.
.
.
.
.
.
.
.
. 49
Figure 6-2
Mounting a Drive in a Carrier
.
.
.
.
.
.
.
.
.
.
.
. 51
Figure 6-3
Removing a Disk Drive Carrier .
.
.
.
.
.
.
.
.
.
.
. 52
.
.
.
.
.
.
xv
Tables
007-5683-001
Table 5-1
Serverboard 16-DIMM Configuration (Four Per CPU) .
.
.
.
.
. 38
Table 5-2
32-DIMM Configuration (8 per CPU)
.
.
.
.
.
.
.
.
.
. 39
Table A-1
BIOS Error Codes
.
.
.
.
.
.
.
.
.
. 83
.
.
.
.
.
xvii
About This Guide
This guide provides an overview of the installation, architecture, general operation, and
descriptions of the major components in the SGI® Rackable™ H2106-G7 server. It also provides
basic troubleshooting and maintenance information, BIOS information, and important safety and
regulatory specifications.
Audience
This guide is written for users of SGI Rackable H2106-G7 server systems. It is written with the
assumption that the reader has a good working knowledge of computers and computer systems.
This guide may be useful to installers and system administrators looking for overview information
on the server.
Chapter Descriptions
The following topics are covered in this guide:
007-5683-001
•
Chapter 1, “Introduction”
Provides an overview of the server’s components.
•
Chapter 2, “Server Installation”
Provides a quick setup checklist to get the server operational.
•
Chapter 3, “System Interface”
Describes several LEDs on the control panel as well as others on the SATA drive carriers
that keep you constantly informed of the overall status of the system as well as the activity
and health of specific components.
•
Chapter 4, “System Safety”
Provides general system safety information.
•
Chapter 5, “System Severboard Information”
xix
Provides best practice procedures to work with a node board in the H2106-G7 chassis, install
memory DIMMs, PCIe expansion cards and hard disk drives.
xx
•
Chapter 6, “Basic Troubleshooting and Chassis Service”
Describes some basic steps required to troubleshoot your system. Additional sections in this
chapter are intended to guide you through basic component remove and replace procedures.
•
Chapter 7, “BIOS”
Describes the AMI BIOS Setup Utility for the system severboard.
•
Appendix A, “BIOS Error Codes,”
Provides a brief listing of BIOS error code information.
•
Appendix B, “System Specifications,”
Describes system component environmental specifications and compliance.
007-5683-001
:
Related Publications
The following SGI and LSI documents may be relevant to the use of your server:
•
MegaRAID SAS Software User’s Guide, publication number, publication number
860-0488-00x
•
MegaRAID 1078-based SAS RAID Controllers User’s Guide, publication number
860-0489-00x
•
LSI Integrated SAS for RAID User’s Guide, publication number 860-0476-00x
•
SGI ProPack series documentation
•
SGI InfiniteStorage series documentation
•
Man pages (online)
You can obtain SGI documentation (as well as the pertinent LSI books), release notes, or man
pages in the following ways:
•
Refer to the SGI Technical Publications Library at http://docs.sgi.com. Various formats are
available. This library contains the most recent and most comprehensive set of online books,
release notes, man pages, and other information.
•
You can also view man pages by typing man <title> on a command line.
SGI systems include a set of Linux® man pages, formatted in the standard UNIX® “man page”
style. Important system configuration files and commands are documented on man pages. These
are found online on the internal system disk (or DVD-CD) and are displayed using the man
command. For example, to display the man page for the xscsidisktest command, type the
following on a command line:
man xscsidisktest
For additional information about displaying man pages using the man command, see man(1).
In addition, the apropos command locates man pages based on keywords. For example, to
display a list of man pages that describe disks, type the following on a command line:
apropos disk
For information about setting up and using apropos, see apropos(1).
007-5683-001
xxi
Conventions
The following conventions are used throughout this document:
Convention
Meaning
Command
This fixed-space font denotes literal items such as commands, files,
routines, path names, signals, messages, and programming language
structures.
variable
The italic typeface denotes variable entries and words or concepts being
defined. Italic typeface is also used for book titles.
user input
This bold fixed-space font denotes literal items that the user enters in
interactive sessions. Output is shown in nonbold, fixed-space font.
[]
Brackets enclose optional portions of a command or directive line.
...
Ellipses indicate that a preceding element can be repeated.
man page(x)
Man page section identifiers appear in parentheses after man page names.
GUI element
This font denotes the names of graphical user interface (GUI) elements such
as windows, screens, dialog boxes, menus, toolbars, icons, buttons, boxes,
fields, and lists.
Product Support
SGI provides a comprehensive product support and maintenance program for its products. SGI
also offers services to implement and integrate Linux applications in your environment.
xxii
•
Refer to http://www.sgi.com/support/
•
If you are in North America, contact the Technical Assistance Center at
+1 800 800 4SGI or contact your authorized service provider.
•
If you are outside North America, contact the SGI subsidiary or authorized distributor in
your country.
007-5683-001
:
Reader Comments
If you have comments about the technical accuracy, content, or organization of this document,
contact SGI. Be sure to include the title and document number of the manual with your comments.
(Online, the document number is located in the front matter of the manual. In printed manuals, the
document number is located at the bottom of each page.)
You can contact SGI in any of the following ways:
•
Send e-mail to the following address: [email protected]
•
Contact your customer service representative and ask that an incident be filed in the SGI
incident tracking system.
•
Send mail to the following address:
SGI
Technical Publications
46600 Landing Parkway
Fremont, CA 94538
SGI values your comments and will respond to them promptly.
007-5683-001
xxiii
Chapter 1
1. Introduction
Important: SGI Rackable server systems may sometimes require driver versions that are not
included in the original operating system release. When required, SGI provides these drivers on
an SGI Driver CD, which may ship with the system, or on the system disk (pre-installed in the
factory). For more information on this topic check with your sales or service representative.
The Rackable H2106-G7 server is a 2U rackmount system (see Figure 1-1). It has two main
subsystems: the 2U server chassis and the four-processor integrated serverboard.
In addition to the serverboard and chassis, various hardware components have been included with
the system, as listed:
007-5683-001
•
One slim DVD-ROM drive (optional)
•
Six 8-cm chassis fans
•
Four passive heatsinks
•
One air shroud
•
SATA or SAS Accessories
•
One or two power supplies
•
One rackmount kit
•
One CD containing drivers and utilities
1
1: Introduction
Figure 1-1
2
Rackable H2106-G7 Server (Top Removed)
007-5683-001
Server Board Features
Server Board Features
At the heart of the system is a four processor serverboard based on the AMD Opteron chipset and
designed to provide maximum performance. Below are the main features of the serverboard.
Processors
The serverboard supports four 8-core or 12-core AMD 6100 series Opteron processors. Each
processor sits in a 1944-pin “G34” socket and is interconnected via HyperTransport (HT) 3.0 link
support, see the next subsection for more information.
HyperTransport Interconnect
The HT link is a packet-based link implemented on two unidirectional sets of signals. The link is
nominally point-to-point, and connects exactly two devices. Devices can have multiple HT links
to allow the construction of larger HT fabrics.
The HT link consists of a point to point x16 link (16 bits) that supports 6.4 GT/s per link in each
direction. The HT link is designed to deliver a scalable, high-performance interconnect between
CPUs and CPU to I/O devices.
Memory
The serverboard has 32 DIMM slots (eight per processor) that support DDR3 1333/1066/800 MHz
DDR3 registered ECC SDRAM (see “Installing Memory” on page 37).
Serial ATA
A Serial ATA controller (AMD SP5100) is integrated into the system serverboard to provide a
six-port 3 Gb/s SATA subsystem, which supports optional RAID 0, 1, and 10. When raided, the
SATA drives are hot-swappable units. Note that your operating system must have RAID support
enabled to accommodate hot swap.
SAS Support
An LSI Serial Attached SCSI controller-equipped system serverboard with on-board RAID
control is available with your system. It provides an eight-port 6Gb/s SAS subsystem, which
007-5683-001
3
1: Introduction
supports RAID 0, 1, 10 and optional RAID 5. When raided, the SAS drives are hot-swappable
units. Note that your operating system must support RAID to use the option.
PCI Expansion Slots
The dual processor serverboard has two low-profile PCI Express 2.0 x16 slots and two low-profile
PCI Express 2.0 x8 slots. The x8 PCIe bus in slot 1 is shared with the system’s UIO slot. See the
following subsection and also the section “PCIe Expansion Cards” on page 42 for more
information on these topics.
UIO
The serverboard is a specially-designed serverboard that features Universal I/O (UIO) technology.
The UIO slot on the serverboard supports specific UIO option cards.
Note: The UIO slot shares the x8 PCIe bus used for slot 1, you can either populate the UIO slot
or PCIe slot 1, but not both slots.
The system does not automatically come with a UIO card pre-installed. Future options may
include RAID, Ethernet or InfiniBand HBAs, contact your sales or service representative for more
information on available product options.
Onboard Controllers/Ports
One onboard ATA/100 connector, which supports IDE hard drives or ATAPI devices. The
color-coded I/O ports include one COM port (an additional COM header is located on the
serverboard), a VGA (monitor) port, two USB 2.0 ports (two additional USB headers and one
Type A port are included on the serverboard), PS/2 mouse and keyboard ports and two gigabit
Ethernet ports.
Onboard Graphics Controller
The four-processor serverboard features an integrated Matrox G200 video controller providing a
16MB DDR2 graphics interface through the system VGA connector. The Matrox video controller
in the 2U server features low power consumption, high reliability and superior longevity.
4
007-5683-001
Server Chassis Features
Other Features
Other onboard features that promote system health include onboard voltage monitors, a chassis
intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus
protection and BIOS rescue.
Server Chassis Features
The following subsections provide a general outline of the main features of the Rackable
H2106-G7 server chassis.
System Power
The Rackable H2106-G7 2U server chassis features an optional redundant power supply
composed of two separate power modules. This power redundancy feature allows you to replace
a failed power supply without shutting down the system. Note that each power supply provides up
to 1400 Watts of power to the system.
Serial ATA and SAS Subsystems
The server chassis optionally supports up to six 3 Gb/s Serial ATA drives or six 6 GB/s SAS
drives. RAID drives are hot-swappable units and are connected to a backplane that provides power
and control. Note that the operating system you have installed must support RAID to enable the
hot-swap capability of RAID drives.
Front Control Panel
The control panel on the H2106-G7 server provides you with system monitoring and control.
LEDs that indicate system power, HDD activity, network activity, system overheat and power
supply failure. A main power button and a system reset button are also included. In addition, two
USB ports and one serial port have been incorporated into the control panel to provide front side
USB and COM port access.
007-5683-001
5
1: Introduction
Serverboard
The H2106-G7 server chassis is an ATX form factor chassis designed to be used in a 2U
rackmount configuration. The serverboard provides one UIO slot, four low-profile PCIe
expansion slots, one DB-9 COM port, a VGA port, two USB 2.0 ports, PS/2 mouse and keyboard
ports and two Gigabit LAN ports. A dedicated RJ-45 IPMI LAN port is also supported. Figure 1-2
on page 7 shows a general block diagram of the H2106-G7 processor and I/O chipset.
Cooling System
The 2U server chassis has an innovative cooling design that includes six 8-cm hot-plug system
cooling fans located in the middle section of the chassis. An air shroud channels the airflow from
the system fans to efficiently cool the processor area of the system. Each power supply module
also includes a cooling fan.
6
007-5683-001
Server Chassis Features
VRM
HT Link
HT Link
CH A0,A1 B0,B1 C0,C1 D0,D1
DDR3-1333/1066
G34-SOCKET #4
8x DIMM
G34-SOCKET #2
PCIE (x4)
Winbond
WPCM450
8x DIMM
HT Link
VGA
Intel
82576
VRM
G34-SOCKET #1
16/16-1GHz
AMD
SR5670
#2
8x DIMM
DDR3-1333/1066
HT Link
HT Link
16/16-1GHz
UIO SLOT
PCIE (X8)
SLOT#2
PCIE (X16)
G34-SOCKET #3
HT Link
8x DIMM
CH A0,A1 B0,B1 C0,C1 D0,D1
DDR3-1333/1066
HT Link
HT Link
VRM
DDR3-1333/1066
VRM
AMD
SR5690
#1
AMD
SP5100
PCIE (X4)
LSI
SAS2 2008
PCIE (X8)
SLOT#1
PCIE_(X8)
PCIE (X8)
SLOT#3
PCIE_(X8)
PCIE (X16)
SLOT#4
PCIE_(X16)
SATA
6x PORTS
SATA_CONN
USB
USB PORT
(0-6)
LPC BUS
Figure 1-2
007-5683-001
H/W_MONITOR
W83795
LPC SIO
W83527DHG-P
9_FAN_CONN.
Keyboard/
Mouse
FWH
Processor and I/O Chipset System Block Diagram
7
Chapter 2
2. Server Installation
This chapter provides a quick setup checklist to get the H2106-G7 operational.
Unpack the System
Inspect the shipping container that the H2106-G7 was shipped in and note if it was damaged in
any way. If the server shows damage, file a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack that supports the weight, power requirements, and
environmental requirements of the H2106-G7 server. It should be situated in a clean, dust-free
environment that is well ventilated. Avoid areas where heat, electrical noise, and electromagnetic
fields are generated. Place the server rack near a grounded power outlet. Refer to “Warnings and
Precautions” on page 10.
Prepare for Setup
The shipping container should include two sets of rail assemblies, two rail mounting brackets and
the mounting screws that you will use to install the system into a rack.
Read this section in its entirety before you begin the installation procedure.
Choose a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door completely (~25
inches) and approximately 30 inches of clearance in the back of the rack to allow for sufficient
airflow and ease in servicing.
007-5683-001
9
2: Server Installation
Warnings and Precautions
Rack Precautions
10
!
Warning: The SGI Rackable H2106-G7 server weighs up to 69 lbs (27.2 kg). Always use
proper lifting techniques when you move the server. Always get the assistance of another
qualified person when you install the sever in a location above your shoulders. Failure to do
so may result in serious personal injury or damage to the equipment.
!
Warning: Extend the leveling jacks on the bottom of the rack to the floor with the full
!
Warning: Attach stabilizers to the rack in single rack installations. Failure to do so can
!
Warning: Couple racks together in multiple rack installations. Failure to do so can result
!
Warning: Be sure the rack is stable before extending a component from the rack. Failure
!
Warning: Extend only one component at a time. Extending two or more components
weight of the rack resting on them. Failure to do so can result in serious injury or death.
result in serious injury or death.
in serious injury or death.
to do so can result in serious injury or death.
simultaneously may cause the rack to tip over and result in serious injury or death.
007-5683-001
Rack Mounting Considerations
Server Precautions
•
Review the electrical and general safety precautions.
•
Determine the placement of each component in the rack before you install the rails.
•
Install the heaviest server components in the bottom of the rack first, and then work up.
•
Use a regulating uninterruptible power supply (UPS) to protect the server from power surges
and voltage spikes and to keep your system operating in case of a power failure.
•
Allow the hot-pluggable SAS/SATA drives and power supply modules to cool before
touching them.
•
Always keep the rack’s front door and all panels and components on the servers closed when
not servicing to maintain proper cooling.
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack
environment may be greater than the ambient temperature of the room. Therefore, consideration
should be given to installing the equipment in an environment compatible with the manufacturer’s
maximum rated ambient temperature (35º C or 95º F).
Reduced Airflow
Equipment should be mounted into a rack so that the amount of airflow required for safe operation
is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to
uneven mechanical loading.
007-5683-001
11
2: Server Installation
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry
and the effect that any possible overloading of circuits might have on overcurrent protection and
power supply wiring. Appropriate consideration of equipment nameplate ratings should be used
when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be
grounded. Particular attention should be given to power supply connections other than the direct
connections to the branch circuit (for example, the use of power strips, and so on).
Install the System into a Rack
This section provides information on installing the H2106-G7 into a rack. If the system has
already been mounted into a rack, refer to “Check the Node Board Setup” on page 16. There are
a variety of rack units on the market, which may mean the assembly procedure will differ slightly.
You should also refer to the installation instructions that came with the rack unit you are using.
Note: This rail will fit a rack between 26" and 33.5" deep.
Separate the Sections of the Rack Rails
The chassis package includes two rail assemblies in the rack mounting kit. Each assembly consists
of two sections: an inner fixed chassis rail that secures directly to the server chassis and an outer
fixed rack rail that secures directly to the rack itself.
To separate the inner and outer rails, perform the following steps:
1.
Locate the rail assembly in the chassis packaging as shown in Figure 2-1.
2. Extend the rail assembly by pulling it outward.
3. Press the quick-release tab
4. Separate the inner rail from the outer rail assembly.
12
007-5683-001
Install the System into a Rack
Rail Assembly
1
Extending the Rails
2
3
QuickRelease Tab
4
Separating the
Inner Rail Extension
7
5
6
Figure 2-1
Separating and Installing the Rack Rails
Outer Rack Rails
Outer rails attach to the rack and hold the chassis in place. The outer rails for the chassis extend
between 30 inches and 33 inches.
007-5683-001
13
2: Server Installation
Install the Outer Rails to the Rack
1.
Secure the back end of the outer rail to the rack, using the screws provided (see Figure 2-1).
2. Press the button where the two outer rails are joined to retract the smaller outer rail.
3. Hang the hooks of the rails onto the rack holes and if desired, use screws to secure the front
of the outer rail onto the rack.
4. Repeat steps 1-3 for the remaining outer rail.
Install the Inner Rail Extension
The H2106-G7 chassis includes a set of inner rails in two sections: inner rails and inner rail
extensions. The inner rails are pre-attached to the chassis, and do not interfere with normal use of
the chassis if you decide not to use a server rack. The inner rail extension is attached to the inner
rail to mount the chassis in the rack.
Install the Inner Rails
Perform the following steps to install the inner rails:
14
1.
Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis
with the rail extension holes. Make sure the extension faces "outward" just like the
pre-attached inner rail.
2.
Slide the extension toward the front of the chassis.
3.
Secure the chassis with 2 screws as illustrated. Repeat steps for the other inner rail
extension.
007-5683-001
Install the System into a Rack
Install the Server in a Rack
!
Warning: The SGI Rackable H2106-G7 server weighs up to 69 lbs (27.2 kg) Always use
proper lifting techniques when your move the server. Always get the assistance of another
qualified person when you install the sever in a location above your shoulders. Failure to do
so may result in serious personal injury or damage to the equipment.
You should now have rails attached to both the server chassis and the rack unit. The next step is
to install the server into the rack (refer to Figure 2-2).
1.
Extend the outer rails as shown in Figure 2-2.
2. Align the inner rails of the chassis with the outer rails on the rack.
3. Slide the inner rails into the outer rails, keeping the pressure even on both sides. When the
chassis has been pushed completely into the rack, it should click into the locked position.
4. Optional screws are recommended to secure and hold the front of the chassis to the rack.
Figure 2-2
007-5683-001
Installing the Server in a Rack
15
2: Server Installation
Check the Node Board Setup
Use the following sections to open the top cover and check that each node board is properly
installed and all the connections have been made.
Access the Inside of the Chassis
1.
Grasp the two handles on either side and pull the unit straight out until it locks (you will hear
a “click”).
2. Depress the two buttons on the top of the chassis to release the top cover as shown in
Figure 2-3.
3. Lift the top cover from the chassis.
Note: To remove the system from the rack completely, depress the locking tabs on the chassis
rails (push the right-side tab down and the left-side tab up) to continue to pull the system out
past the locked position.
16
007-5683-001
Check the Node Board Setup
Figure 2-3
007-5683-001
Accessing the Inside of the System
17
2: Server Installation
Check the CPUs (processors)
Standard factory systems ship with four processors installed into the serverboard. Each processor
needs its own heatsink.
Check the System Memory
Your server system is shipped with system memory installed. Make sure all DIMMs are fully
seated in their slots. For details on adding system memory, refer to Chapter 3.
Install Expansion PCIe Cards
You can install expansion PCIe cards in the system. Refer to Chapter 3 for information on
installing PCIe expansion cards.
Check all Cable Connections and Airflow
Make sure all power and data cables are properly connected and not blocking the chassis airflow.
Refer to Chapter 3 for details on cable connections.
Check the Drive Bay Setup
Next, you should check to make sure the system disk drives and disk drive backplane have been
properly installed and all connections have been made.
Check the System Disk Drives
All drives are accessible from the front of the server. For servicing the DVD-ROM, you will need
to remove the top chassis cover. The hard drives can be installed and removed from the front of
the chassis without removing the top chassis cover. Depending upon your system configuration,
your system may have one or more drives installed. For detailed information about how to install
disk drives, see “Hard Disk Drives (H2106-G7 Chassis)” on page 40.
If you have more than 4TB of storage, you must create multiple volumes to fully utilize your
RAID disks.
18
007-5683-001
Check the Node Board Setup
A slim DVD-ROM may be pre installed in your server. Refer to Chapter 6 if you need to install a
DVD-ROM disk drive to the system.
Depending upon your system's configuration, your system may have one or more drives already
installed. If you need to install hard drives, please refer to Chapter 6.
Check the Airflow
Airflow is provided by eight hot-swappable 8-cm chassis cooling fans. The system component
layout was carefully designed to direct sufficient cooling airflow to the components that generate
the most heat.
Note: Make sure that all power and data cables have been routed in such a way that they do not
block the airflow generated by the fans.
Supply Power to the System
If necessary, install the system in a rack (refer to “Install the System into a Rack” on page 12), and
connect the power cords from the power supply modules into a power strip or power distribution
unit (PDU). SGI also recommends that you use an optionally available uninterruptible power
supply (UPS) source.
007-5683-001
19
Chapter 3
3. System Interface
Overview
There are several LEDs on the control panel as well as others on the drive carriers and power
supplies to keep you constantly informed of the overall status of the system, see Figure 3-1.
Slim DVD-ROM
drive
Power
supplies
USB
ports
Front
COM
port 2
System
LEDs
System
reset
2
Main
power
1
RESET
COMPACT
Keyboard
PCI expansion slots
IPMI LAN
Mouse
Rear
Serial
port
VGA
port
Ethernet
ports
USB
ports
Figure 3-1
007-5683-001
System Front and Rear Interface Components
21
3: System Interface
Control Panel Buttons
In addition to monitoring the activity and health of specific components using LEDs, the system
uses two buttons located on the front of the chassis: a reset button and a power on/off button. Use
the reset button to reboot the system as shown in Figure 3-2.
Figure 3-2
System Reset Button
Figure 3-3 shows the main power button, which is used to apply or turn off the main system power.
Turning off system power with this button removes the main power but keeps standby power
supplied to the system.
Figure 3-3
22
System Power On Button
007-5683-001
Control Panel LEDs
Control Panel LEDs
The control panel located on the front of the chassis has several LEDs. These LEDs provide you
with critical information related to different parts of the system. This section explains what each
LED indicates when illuminated and any corrective action you may need to take.
Power Fail
The power fail LED indicates a power supply module has failed as shown in Figure 3-4. The
(optionally available) second power supply module will take the load and keep the system running
but the failed module will need to be replaced. Refer to Chapter 6 for details on replacing the
power supply. This LED should be off when the system is operating normally.
Figure 3-4
Power Fail LED
Overheat/Fan Fail
When the red overheat/fan LED flashes (shown in Figure 3-5), it indicates a fan failure. When on
continuously it indicates an overheat condition, which may be caused by cables obstructing the
airflow in the system or the ambient room temperature being too warm.
Check the routing of the cables and make sure all fans are present and operating normally. You
should also check to make sure that the chassis covers are installed. This LED will remain flashing
or on as long as the indicated condition exists.
Figure 3-5
007-5683-001
Overheat/Fan Fail LED
23
3: System Interface
NIC1
When flashing, the NIC1 LED indicates network activity on the LAN1 port (see Figure 3-6).
1
Figure 3-6
LAN1 Network Activity NIC1 LED
NIC2
When flashing, the NIC2 LED indicates network activity on the LAN2 port (see Figure 3-7).
2
Figure 3-7
LAN2 Network Activity NIC2 LED
HDD
The HDD LED indicates hard drive activity when flashing (see Figure 3-8).
Figure 3-8
24
Hard Drive Activity LED
007-5683-001
Drive Carrier LEDs
Power
The power LED indicates power is being supplied to the system's power supply unit(s) is shown
in Figure 3-9. This LED should normally be illuminated when the system is operating.
Figure 3-9
Power On LED
Drive Carrier LEDs
Each hard disk drive carrier has two LEDs, as follows:
007-5683-001
•
Green: When illuminated, the green LED on the drive carrier indicates drive activity. A
connection to the drive backplane enables this LED to blink on and off when that particular
drive is being accessed. Please refer to Chapter 6 for instructions on replacing failed drives.
•
Red: The red LED indicates a drive failure. If one of the drives fails, you should be notified
by your system management software. Please refer to Chapter 6 for instructions on replacing
failed drives.
25
Chapter 4
4. System Safety
This chapter describes basic safety precautions.
Electrical Safety Precautions
Basic electrical safety precautions should be followed to protect yourself from harm and the
Rackable H2106-G7 system from damage, as follows:
007-5683-001
•
Be aware of the locations of the power on/off switch on the chassis as well as the room's
emergency power-off switch, disconnection switch or electrical outlet. If an electrical
accident occurs, you can then quickly remove power from the system.
•
Do not work alone when working with high voltage components.
•
Power should always be disconnected from the system when removing or installing main
system components, such as the memory modules and disk drives. When disconnecting
power, you should first power down the operating system and then unplug the power cords.
The unit can have more than one power supply cord. Disconnect two power supply cords
before servicing to avoid electrical shock.
•
When working around exposed electrical circuits, another person who is familiar with the
power-off controls should be nearby to switch off the power if necessary.
•
Use only one hand when working with powered-on electrical equipment. This is to avoid
making a complete circuit, which will cause electrical shock. Use extreme caution when
using metal tools, which can easily damage any electrical components or circuit boards they
come into contact with.
•
Do not use mats designed to decrease static electrical discharge as protection from electrical
shock. Instead, use rubber mats that have been specifically designed as electrical insulators.
•
The power supply power cords must include a grounding plug and must be plugged into
grounded electrical outlets or power distribution unit (PDUs).
27
4: System Safety
Serverboard Battery
!
Caution: There is a danger of explosion if the onboard battery is installed upside down,
which will reverse its polarities (see Figure 4-1). This battery must be replaced only with the
same or an equivalent type recommended by the manufacturer. Check with your service
representative if you have any questions. Dispose of used batteries according to the
manufacturer's instructions.
Lithium battery
Battery holder
Figure 4-1
Installing the Onboard Battery
DVD-ROM Laser
!
Caution: This server may have come equipped with a DVD drive. To prevent direct
exposure to the laser beam and hazardous radiation exposure, do not open the drive enclosure
or use the unit in any unconventional way.
Mainboard Replaceable Soldered-in Fuses
Important: If your system comes with self-resetting PTC (Positive Temperature Coefficient)
fuses on the serverboard, they must be replaced by trained service technicians only. The new fuse
must be the same or equivalent as the one replaced. Contact your technical support organization
for details and support.
28
007-5683-001
General Safety Precautions
General Safety Precautions
Follow these rules to ensure general safety:
•
Keep the area around the Rackable H2106-G7 system clean and free of clutter.
•
The Rackable H2106-G7 system weighs approximately 69 lbs (27.2 kg.) when fully loaded.
When lifting the system, two people at either end should lift slowly with their feet spread out
to distribute the weight. Always keep your back straight and lift with your legs.
•
Place the chassis top cover and any system components that have been removed away from
the system or on a table so that they won't accidentally be stepped on.
•
While working on the system, do not wear loose clothing such as neckties and unbuttoned
shirt sleeves, which can come into contact with electrical circuits or be pulled into a cooling
fan.
•
Remove any jewelry or metal objects from your body, which are excellent metal conductors
that can create short circuits and harm you if they come into contact with printed circuit
boards or areas where power is present.
•
After accessing the inside of the system, close the system back up and secure it to the rack
unit with the retention screws after ensuring that all connections have been made.
ESD Precautions
!
Caution: Electrostatic discharge (ESD) is generated by two objects with different electrical
charges coming into contact with each other. An electrical discharge is created to neutralize this
difference, which can damage electronic components and printed circuit boards.
The following measures are generally sufficient to neutralize this difference before contact is
made to protect your equipment from ESD:
007-5683-001
•
Use a grounded wrist strap designed to prevent static discharge.
•
Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for
use.
•
Touch a grounded metal object before removing the board from the antistatic bag.
•
Do not let components or PCBs come into contact with your clothing, which may retain a
charge even if you are wearing a wrist strap.
29
4: System Safety
30
•
Handle a board by its edges only; do not touch its components, peripheral chips, memory
modules or contacts.
•
When handling chips or modules, avoid touching their pins.
•
Put the serverboard and peripherals back into their antistatic bags when not in use.
•
For grounding purposes, make sure your computer chassis provides excellent conductivity
between the power supply, the case, the mounting fasteners and the serverboard.
007-5683-001
Chapter 5
5. System Serverboard Information
This chapter includes best practice procedures to work with a node board in the H2106-G7 chassis,
install memory DIMMs, PCIe expansion cards and hard disk drives.
A layout and quick reference chart is included in this chapter for your reference. See “Installing
Memory” on page 37.
Note: Some software products are protected with software license keys derived from the
Media Access Control (MAC) Ethernet address. If your system requires the replacement of a node
board, the MAC Ethernet address changes. If you are using such a product, you must request a
new license key after replacing the node board. Contact your local customer support office:
http://www.sgi.com/support/supportcenters.html
!
Caution: Install the chassis cover after you have completed accessing the components inside the
server to maintain proper airflow and cooling for the system.
Handling the Node Board
!
007-5683-001
Caution: Electrostatic discharge (ESD) can damage electrostatic-sensitive devices inside the
H2106-G7 server. Use the ESD precautions described below when you handle printed circuit
boards or other components in the system. The following measures are generally sufficient to
protect your equipment from electric static discharge.
31
5: System Serverboard Information
ESD Precautions
•
Use a grounded wrist strap designed to prevent electrostatic discharge.
•
Touch a grounded metal object before removing any board from its antistatic bag.
•
Handle each printed circuit board (PCB) by the edges; do not touch the components,
peripheral chips, memory modules, or gold contacts on the PCB.
•
When handling chips or modules, avoid touching the pins.
•
Place the node board, expansion PCI cards, or other boards and components into antistatic
bags when not in use.
•
Make sure your computer chassis provides a conductive path between the power supply, the
case, the mounting fasteners, and the node board to chassis ground.
Unpacking
!
Caution: The node board is shipped in antistatic packaging to avoid electrostatic discharge
damage. Be sure to use ESD precautions when you unpack replacement components for the
H2106-G7 server. Failure to do so can result in damage to the equipment.
Connecting the Control Panel
JF1 contains header pins for various front control panel connectors. See Figure 5-1 for the pin
locations of the various front control panel buttons and LED indicators.
All JF1 wires have been bundled into a single cable to simplify this connection. Make sure the red
wire plugs into pin 1 as marked on the board. The other end connects to the Control Panel PCB
board, located just behind the system status LEDs on the chassis.
32
007-5683-001
Serverboard I/O Ports
20
Ground
NMI
x (Key)
x (Key)
Power On LED
Vcc
HDD LED
Vcc
NIC1 LED
Vcc
NIC2 LED
Vcc
OH/Fan Fail LED
Vcc
Power Fail LED
Vcc
Ground
Reset (Button)
Ground
Power (Button)
2
Figure 5-1
19
1
Control Panel Header Pins
Serverboard I/O Ports
The I/O ports are color coded in conformance with the PC 99 specification. See Figure 5-2 below
for the colors and locations of the various I/O ports.
Figure 5-2
007-5683-001
I/O Ports Locations
33
5: System Serverboard Information
Serverboard Details
The 2U H2106-G7 system chassis has one node board. The H2106-G7 serverboard is configured
with up to four processors. When properly configured with four processors, the following rules
apply:
•
All processor sockets must have identical revisions, core voltage, and bus/core speed.
•
The stepping between the processors on the board must be identical.
•
See Figure 5-3 for CPU locations on the serverboard - note that the drawing is not to scale.
•
Quad AMD Opteron 6100 series (Socket G34 type) processors
CPUs
Note: A minimum of four processors must be installed for full functions to be supported.
Memory
•
Thirty-Two (32) single/dual/tri/quad channel DIMM slots supporting up to 512 GB of
DDR3-1333/1066/800 registered ECC or 128GB of DDR3 Unbuffered ECC/non-ECC
SDRAM
Note: Refer to the memory installation information in this guide before installing new
memory. Check with your authorized sales/service representative for approved DIMM types.
Chipsets
•
One AMD SR5690 plus one SR5670 and one SP5100 Southbridge chipset
•
Two (2) PCI-Express x16 Gen. 2
•
Two (2) PCI-Express x8 Gen. 2
•
One (1) UIO BIOS
•
16 Mb AMIBIOS® SPI Flash ROM
•
APM 1.2, DMI 2.3, PCI 2.2, ACPI 1.0 (ACPI 2.0 is BIOS supported), SMBIOS 2.3, Real
Time Clock Wakeup, Plug and Play (PnP), BIOS resume hot keys
Expansion Slots
34
007-5683-001
Serverboard I/O Ports
PC Health Monitoring
•
Onboard voltage monitors
•
Fan status monitor with firmware/software on/off and speed control
•
Watch Dog
•
Environmental temperature monitoring via BIOS
•
Power-up mode control for recovery from AC power loss
•
System resource alert (via included utility program)
•
Auto-switching voltage regulator for the CPU core
•
CPU thermal trip support
•
I2C temperature sensing logic
•
Chassis intrusion detection
•
Microsoft OnNow available
•
Slow blinking LED for suspend state indicator
•
BIOS support for USB keyboard
•
Wake-On-LAN (WOL)
•
Internal/external modem ring-on
•
Hardware BIOS Virus protection
•
Six (6) SATA ports supported by an on-chip SATA controller (RAID 0, 1, 10 supported)
•
Eight (8) SAS ports supported by an LSI 2008 SAS2 controller (RAID 0, 1, 10 supported;
Raid 5 Optional) (SAS only) See Figure 5-3 on page 36
•
Two (2) Fast UART 16550 compatible serial ports (one header and one port)
•
Seven (7) USB (Universal Serial Bus 2.0) ports (2x rear [external], 4x header,1x type A)
•
Two (2) LAN ports supported by an onboard Intel® 82576 dual port Ethernet controller for
10/100/1000Base-T
•
One (1) dedicated IPMI LAN port
ACPI Features
Onboard I/O
007-5683-001
35
5: System Serverboard Information
KB/
MOUSE
IPMI LAN
USB0/1
JTPM1
USB6
P4-DIMM4B
P4-DIMM3B
P4-DIMM4A
P4-DIMM3A
P4-DIMM2B
P4-DIMM2A
P4-DIMM1B
P4-DIMM1A
P2-DIMM4B
P2-DIMM4A
P2-DIMM3B
P2-DIMM2B
P2-DIMM3A
P2-DIMM1B
P2-DIMM2A
P2-DIMM1A
JF1
JD1
JIBTN1
DP3
P3-DIMM1A
P3-DIMM1B
P3-DIMM2B
P3-DIMM2A
P3-DIMM3B
P3-DIMM3A
P3-DIMM4A
P3-DIMM4B
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
P1-DIMM4B
P1-DIMM4A
SLOT4 PCI-E 2.0 X16
SLOT3 PCI-E 2.0 X8
SLOT2 PCI-E 2.0 X16
JI2C2
JI2C1
JL1
COM2
JPW4
FAN1
FAN2
FAN3
FAN4
FAN5
FAN6
JOH1
JPS1
3-SGPIO1
3-SGPIO2
Node Board Features
Figure 5-3
CPU3
CPU4
CPU2
T-SGPIO1
T-SGPIO2
JPW1
JPW3 JPW2
JPI2C1
SLOT1 PCI-E 2.0 X8
UIO PCI-E 2.0 X8
JPUSB1
USB4/5
USB2/3
LSI
2008
SAS2
AMD
SR5670
SAS7
SAS6
SAS5
SAS4
SAS3
SAS2
SAS1
SAS0
JWF1
SATA5
SATA4
SATA3
SATA2
SATA1
SATA0
AMD
SR5690
AMD
SP5100
LAN1
JPB1
Battery
JBT1
JWOL1
LAN2
JPL1
JPG1
FAN7
DP1
007-5683-001
36
JWD1
CPU1
FAN8
BMC
COM1
VGA
LE1
UID
FAN9
Intel
82576
JSMB1
One (1) VGA port supported by an onboard Matrox® G200 graphics controller (with 16 MB
DDR2 memory)
•
Serverboard Dimensions
Proprietary format: 16.48" x 13" (418 mm x 330 mm)
Installing Memory
Installing Memory
!
Caution: Exercise extreme care when installing or removing DIMM modules to prevent any
possible damage.
The H2106-G7 serverboard supports up to 32 DIMM slots. Three-way interleaved memory is
supported. For optimal memory performance always use memory modules of the same type and
speed. See the following table for memory installation.
Install DIMMs
Perform the following steps to install memory modules, as follows:
1.
Insert the DIMM module vertically and press down into its slot until it snaps into place. Pay
attention to the alignment notch at the bottom of the module to avoid installing incorrectly
(see Figure 5-4). Insert the desired number of DIMMs into the memory slots, beginning with
DIMM #1A and DIMM #2A, then DIMM #3A and DIMM #4A, etc. (see Table 5-1 on
page 38 for 16-DIMM placement). Always spread DIMMs across all banks for each CPU.
Gently press down on the DIMM module until it snaps into place in the slot. Repeat for all
modules.
2. Install to slots CPU1/DIMM1A, CPU1/DIMM2A, CPU1/DIMM3A and CPU1/DIMM4A,
etc. Always install in groups of four and in the numerical order of the DIMM slots. See
support information below.
3. Gently press down on the memory module until it snaps into place.
4. With four CPUs installed, repeat step 2 to populate each of the four CPU DIMM slots. See
Table 5-2 on page 39 for 32-DIMM application on a serverboard.
For the most efficient operation, always install four or eight DIMMs to support each CPU.
Note: 1 GB, 2 GB, 4 GB, 8 GB and 16 GB memory modules are supported. It is highly
recommended that you remove the power cord from the system before installing or changing
memory modules. Check with your sales or service representative for memory that has been tested
and approved for the serverboard.
007-5683-001
37
5: System Serverboard Information
Memory Support
The serverboard supports single/dual/tri/quad-channel, DDR3-1333/1066/800 registered
ECC/Unbuffered ECC/non-ECC SDRAM. Only interleaved memory is supported, so you must
populate four DIMM slots at a time (see procedure above).
Populating four adjacent slots at a time with memory modules of the same size and type will result
in interleaved (128-bit) memory, which is faster than non-interleaved (64-bit) memory.
5. To remove a DIMM module, use your thumbs to gently push the release tabs near both ends
of the module (see Figure 5-4). This should release it from the slot.
1
Front view
Notch
Notch
2
Release tab
Release tab
Top view of DDR3 slot
38
Figure 5-4
DIMM Installation Example
Table 5-1
Serverboard 16-DIMM Configuration (Four Per CPU)
#DIMMs
CPU
Channel 1
Channel 2
Channel 3
Channel 4
16 DIMMs
CPU1
P1-1A
P1-2A
P1-3A
P1-4A
CPU2
P2-1A
P2-2A
P2-3A
P2-4A
CPU3
P3-1A
P3-2A
P3-3A
P3-4A
CPU4
P4-1A
P4-2A
P4-3A
P4-4A
007-5683-001
Installing Memory
Table 5-2
32-DIMM Configuration (8 per CPU)
#DIMMs
CPU
Channel 1
Channel 2
Channel 3
Channel 4
32 DIMMs
CPU1
P1-1A & P1-1B
P1-2A & P1-2B
P1-3A & P1-3B
P1-4A & P1-4B
CPU2
P2-1A & P2-1B
P2-2A & P2-2B
P2-3A & P2-3B
P2-4A & P2-4B
CPU3
P3-1A & P3-1B
P3-2A & P3-2B
P3-3A & P3-3B
P3-4A & P3-4B
CPU4
P4-1A & P4-1B
P4-2A & P4-2B
P4-3A & P3-3B
P4-4A & P4-4B
Memory DIMM Layout
The H2106-G7 memory bus is a quad-channel controller intended for use with four processor
configurations. Note that memory DIMM slots should be populated equally in adjacent memory
banks on each channel.
Memory DIMM Rules
Use the following rules when installing memory DIMMs:
The minimum memory recommended on the system is 16 GB.
007-5683-001
•
Populate the DIMMs in groups of four or eight per CPU as described in Table 5-1 on
page 38 and Table 5-2 on page 39.
•
A minimum of four DIMMs per processor must always be present.
•
Mixing DIMM Sizes - When mixing DIMMs on a channel that has a mixed number of ranks,
it is recommended to have the total number of ranks on the channel be even to avoid
bandwidth degradation. Example: placing a single-rank DIMM and a dual-rank DIMM on
the same channel is not desirable.
•
For maximum memory performance the DIMMs within a node must be identical in:
–
Speed (1066 or 1333 Mtransfer/sec)
–
Number of ranks (1 or 2)
39
5: System Serverboard Information
Note: The speed of the memory controller will reduce to the lowest speed DIMM on the channel.
•
When configuring the memory for maximum performance, it is critical that the memory
DIMM capacity is balanced across all memory channels.
The maximum speed of the memory controller changes based on the number of DIMMs placed
on the channel:
•
Four DIMMs on the channel the maximum speed supported is 1333 MT/s
•
Eight DIMMs on the channel the maximum speed supported is 1066 MT/s
Reason for the decrease in memory performance - as more DIMMs are added to a channel the
noise on the channel increases and the voltage levels decrease due to signal loading. As a result
we have to lower the frequency that we run the channel as more DIMMs are added.
Three conditions must be met to have a memory speed of 1333 MT/s:
•
The processor must be capable of supporting 1333 MT/s
•
The DIMM must be capable of running at 1333 MT/s
•
Four or fewer DIMMs are placed on each channel.
Hard Disk Drives (H2106-G7 Chassis)
The 2U chassis supports a maximum of six SAS or SATA disk drives. Install the drives from left
to right starting in the bottom-left bay. Disk drive bays must be populated with either a drive or a
“drive blank” to maintain system thermals. Failure to follow this guideline may cause system
overheating and thermal shutdown of the unit.
RESET
COMPACT
Figure 5-5
40
Drive 3
Drive 4
Drive 5
Drive 0
Drive 1
Drive 2
H2106-G7 Disk Drive Locations
007-5683-001
Hard Disk Drives (H2106-G7 Chassis)
Drive Configurations
The disk drive configurations supported in the Rackable H2106-G7 server are outlined in the
paragraphs that follow. Note that some configurations are dependent on use of optional SAS
drives in the system. The system must have an optional SAS enabled serverboard to use SAS
drives as either Jbod or RAID.
The supported disk drive configurations are as follows:
007-5683-001
•
JBOD
This non-RAID disk array supports any number of drives between one and six. The
operating system is placed on the disk drive in location 0. All other drives are data drives.
•
RAID0
Disk striping without parity, supports any number of drives between two and six. Note that
all drives must be the same type. The operating system will be striped across all drives in the
system. This configuration is not recommended.
•
RAID1
Disk mirroring, supports exactly two drives. The two drives represent one RAID1 logical
drive. The operating system will be installed on the drives located in Drive 0 and 1. Note that
both drives must be of the same type, speed and size.
•
RAID5
Optional disk striping with parity, supports a minimum of three drives and a maximum of six
drives. Possible configurations are 2+1, 3+1, 4+1, and 5+1. The operating system will be
striped across all drives in the system. Note that all disks must be SAS drives of the same
type and capacity. This option is only supported with a SAS-enabled serverboard.
•
RAID10
Mirrored disk striping, the data is striped across one set of drives and then mirrored on
another set of drives. A minimum of four drives of the same type are required. The total
number of drives must be an even number (4 or 6). A total of four drives is a 2+2 and six
drives is a 3+3,. The operating system will be striped across all drives in the primary set and
then mirrored on the secondary set of drives. Note that all drives must be the same type,
speed and capacity.
41
5: System Serverboard Information
PCIe Expansion Cards
A riser card is used to support a standard size (full height full length) PCI expansion card.
There are three PCIe expansion slot types available with the H2106-G7 server:
•
Two PCIe 2.0 x16 slots
•
Two PCIe 2.0 x8 slots
•
One UIO slot
Note: The UIO slot shares the x8 PCIe bus used for slot 1, you can either populate the UIO slot
or PCIe slot 1, but not both slots. Select option cards can use the UIO slot, contact your sales or
service representative for information on approved option cards.
Installing a PCIe Expansion Card
Confirm that you have the correct riser card for your chassis model and the add-on card includes
a standard bracket.
1.
Remove the chassis cover.
2. Install the riser card by sliding card into the appropriate riser card in the serverboard.
3. Choose the PCI slot shield in which to place the add-on card.
4. In that slot, open the PCI slot shield lever and slide the shield sideways.
5. From inside the chassis, remove the PCI slot shield.
6. Slide the add-on card into the riser card and attach the add-on card bracket in place of the
PCI slot shield.
7. Secure the add-on card by closing the PCI slot shield lever.
8. Connect cables to the add-on card as necessary.
42
007-5683-001
PCIe Expansion Cards
Power Supply Functional Rating
The H2106-G7 server default configuration is one front-installed 1200W/1400W power supply.
The optional second power supply acts as a redundant power unit for the server. The supplies can
operate from either 100-140V or 180-240V levels at 50 or 60Hz.
A power supply will produce 1200 Watts when supplied with a 100-140V input. A supply will
produce 1400 Watts when supplied with a 180-240V input.
The supplies used have an 80 Plus Gold Certification rating.
007-5683-001
43
Chapter 6
6. Basic Troubleshooting and Chassis Service
Use the procedures in the first half of this chapter to troubleshoot your system. If you have
followed all of the procedures below and still need assistance, check with your authorized support
organization.
The subsections in the second half of this chapter starting with “Chassis Service Information” on
page 47 are intended to guide you through basic component remove and replace procedures.
Basic Troubleshooting Procedures
Use the information in the following subsections to remedy basic problems you might encounter
when working with the Rackable H2106-G7 server.
If the System Does Not Power Up
If the system will not power up when the front power button is pushed, use the following checklist
to identify common sources for the problem:
•
Make sure that both ends of each system power cable are firmly connected to the power
supply and the corresponding power source(s) or power distribution unit (PDU).
•
Check that the LED on each power supply is properly lit. The power supply has one status
LED located on the left side of the front of the power supply. The status LED has three states
as follows:
•
007-5683-001
–
Dark or off - indicates no AC power present
–
Yellow - AC power is present, the server is not turned on (no DC power)
–
Green - AC power is present and the server is turned on (DC power present)
Open the system cover, remove the air shroud and check to make sure that no obvious short
circuits exist between the serverboard and chassis.
45
6: Basic Troubleshooting and Chassis Service
System Powers Up But Will Not Boot
If the system powers up but will not boot the Operating System, check the following:
•
Check the system order document(s) - the H2106-G7 server may have been ordered with no
operating system. If so, check with your system administrator for OS loading information.
•
Check the system disk for drive activity and confirm that it is firmly seated in the disk bay. A
red light on the front of the disk indicates a functional error. Check with your service
provider or local system administrator.
No Video After System Power Up
If the system powers up and appears to be booting normally but no video is present, try the
following basic solutions:
•
Confirm your monitor is plugged in and switched on.
•
Check all video cables and ensure they are properly connected.
•
If using an optional PCIe video card check the back of the card for LED activity or a fault
indicator. Try opening the system, reseating the PCI card and rebooting.
If you cannot get a video signal after trying basic solutions contact your support provider.
Memory Errors
If your system experiences memory related errors, try these basic troubleshooting steps to resolve
or better identify the problem:
•
Confirm that the power supply LED is not indicating an error.
•
Shut the system down, remove the covers over the serverboard and make sure that all the
DIMM modules are properly and fully installed.
•
You should be using registered ECC DDR3 memory. Also, it is recommended that you use
the same memory type and speed for all DIMMs in the system. See Chapter 5 for more
memory details.
•
Check for bad DIMM modules or slots by swapping modules between slots and noting the
results.
Contact your administrator or support provider if the memory errors continue.
46
007-5683-001
Chassis Service Information
Chassis Service Information
The following sections cover the steps required to install components and perform maintenance
on the H2106-G7 chassis. For component installation, follow the steps in the order given to
eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to
the step that follows.
Important: Always disconnect the AC power cord(s) before adding, changing or installing any
internal hardware components.
Tools Required: The only tool you will need to install components and perform maintenance is
a Phillips screwdriver.
Static-Sensitive Devices
Electrostatic discharge (ESD) can damage electronic components. To prevent damage to any
printed circuit boards (PCBs), it is important to handle them very carefully. The following
measures are generally sufficient to protect your equipment from ESD damage.
Precautions
007-5683-001
•
Use a grounded wrist strap designed to prevent static discharge.
•
Touch a grounded metal object before removing any board from its antistatic bag.
•
Handle a board by its edges only; do not touch its components, peripheral chips, memory
modules or gold contacts.
•
When handling chips or modules, avoid touching their pins.
•
Put the serverboard, add-on cards and peripherals back into their antistatic bags when not in
use.
•
For grounding purposes, make sure your computer chassis provides excellent conductivity
between the power supply, the case, the mounting fasteners and the serverboard.
47
6: Basic Troubleshooting and Chassis Service
Unpacking
Replacement components are usually shipped in antistatic packaging to avoid static damage.
When unpacking an upgrade or replacement component, make sure the person handling it is static
protected.
Control Panel
The control panel (located on the front of the chassis) must be connected to the JF1 connector on
the serverboard to provide you with system status indications. A ribbon cable has bundled these
wires together to simplify the connection. Connect the cable from JF1 on the serverboard to the
Control Panel PCB (printed circuit board). Make sure the red wire plugs into pin 1 on both
connectors. Pull all excess cabling out of the airflow path. The LEDs inform you of system status.
See Chapter 3 for details on the LEDs and the control panel buttons. Details on JF1 can be found
in Chapter 5.
System Fans
Six 8-cm hot-swap fans provide the cooling for the system. It is very important that the chassis top
cover is properly installed and making a good seal in order for the cooling air to circulate properly
through the chassis and cool the components. See Figure 6-2.
48
007-5683-001
System Fans
Figure 6-1
System Cooling Fan Locations
System Fan Failure
Fan speed is controlled by system temperature via a BIOS setting. If a fan fails, the remaining fans
will ramp up to full speed and the overheat/fan fail LED on the control panel will turn on. Replace
007-5683-001
49
6: Basic Troubleshooting and Chassis Service
any failed fan at your earliest convenience with the same type and model (the system can continue
to run with a failed fan). Remove the top chassis cover while the system is still running to
determine which of the fans has failed.
Replacing System Fans
This section describes how to remove or install a system fan.
Removing a Fan
1.
Remove the chassis cover.
2. Press the tabs on the sides of the fan to unlock and remove the fan and its housing. The fan's
power connections will automatically detach.
3. System power does not need to be shut down since the fans are hot-pluggable.
Installing a New Fan
1.
Replace the failed fan with an identical 8-cm, 12 volt fan.
2. Position the new fan into the space vacated by the failed fan previously removed. A "click"
can be heard when the fan is fully installed in place and the power connections are made.
3. If the system power is on, the hot-plug feature will cause the fan to start immediately upon
being connected to its header on the serverboard.
Drive Bay Installation/Removal
This section describes drive bay installation and removal.
Accessing the Drive Bays
Drives: You do not need to access the inside of the chassis or remove power to replace or swap a
RAIDed hard disk drive. Data may be lost or corrupted if you hot swap a Jbod disk drive.
Removing a drive without replacing it may cause system errors. Proceed to the next section for
further hard drive instructions.
50
007-5683-001
Drive Bay Installation/Removal
Note: You must use approved standard 1" high, disk drives in the system.
DVD-ROM Drive: For installing/removing the DVD-ROM disk drive, you will need to gain
access to the inside of the server by removing the top cover of the chassis. Proceed to the
"DVD-ROM Drive Installation" section later in this chapter for instructions.
Disk Drive Installation
The drives are mounted in drive carriers to simplify their installation and removal from the
chassis. These carriers also help promote proper airflow for the drives. For this reason, even empty
carriers without hard drives installed must remain in the chassis.
Mounting a Disk Drive in a Drive Carrier
1.
To add a new drive, install the drive into the carrier with the printed circuit board side facing
down so that the mounting holes align with those in the carrier.
2. Secure the drive to the carrier with four screws, as shown in Figure 6-2.
Figure 6-2
007-5683-001
Mounting a Drive in a Carrier
51
6: Basic Troubleshooting and Chassis Service
Installing/Removing Hot-swap Drives
1.
Push the release button located beside the drive's LEDs.
2. Swing the handle fully out and use it to pull the drive carrier straight out (see Figure 6-3).
Handle
Release button
Figure 6-3
Removing a Disk Drive Carrier
Note: Your operating system must have RAID support to enable the hot-plug capability of the
drives.
!
52
Important: Regardless of how many hard drives are installed, all drive carriers must remain in
the drive bays to maintain proper airflow.
007-5683-001
Drive Bay Installation/Removal
!
Caution: Use caution when working around the drive backplane. Do not touch the backplane
with any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes,
which aid in proper airflow.
Hard Drive Backplane
The hard drives plug into a backplane that provides power, drive ID and bus termination. A RAID
controller and/or optional RAID software can be used with the backplane to provide data security.
The operating system you use must have RAID support to enable the hot-swap capability of the
hard drives. The backplane is already preconfigured, so no jumper or switch configurations are
required.
DVD-ROM Drive Installation
The top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay. The
system accommodates only slim type DVD-ROM drives. Side mounting brackets are typically
needed to mount a slim DVD-ROM drive in the server.
Accessing the Inside of the Chassis
1.
Grasp the two handles on either side and pull the unit straight out until it locks (you will hear
a "click").
2. Next, depress the two buttons on the top of the chassis to release the top cover and at the
same time, push the cover away from you until it stops. You can then lift the top cover from
the chassis to gain full access to the inside of the server.
Note: You must power down the system before installing or removing IDE components.
Drives mount on rails and should "click" into place to be correctly and fully installed in their bays.
007-5683-001
53
6: Basic Troubleshooting and Chassis Service
Power Supply
The system has a 1200/1400 watt redundant power supply consisting of one or (optionally) two
power modules. Each power supply module has an auto-switching capability, which enables it to
automatically sense and operate at a 100V - 240V input voltage.
Power Supply Failure
If your system has an optional second power supply and either of the two power supply modules
fail, the other module will take the full load and allow the system to continue operation without
interruption. The PWR Fail LED will illuminate and remain on until the failed unit has been
replaced. The power supply units have a hot-swap capability, meaning you can replace the failed
unit without powering down the system.
Removing/Replacing the Power Supply
If the server is equipped with an optional second power supply, you do not need to shut down the
system to replace a power supply unit. The optional backup power supply module will keep the
system up and running while you replace the failed unit. Replace with the same model.
Removing the Power Supply
1.
First unplug the AC power cord from the failed power supply module.
2. Depress the locking tab on the power supply module.
3. Pull it straight out using the rounded handle.
Installing a New Power Supply
1.
Replace the failed hot-swap unit with another identical power supply unit.
2. Push the new power supply unit into the power bay until you hear a click.
3. Secure the locking tab on the unit.
4. Finish by plugging the AC power cord back into the unit.
54
007-5683-001
Chapter 7
7. BIOS
This chapter describes the AMI BIOS Setup Utility for the severboard. The AMI ROM BIOS is
stored in a Flash EEPROM and can be updated when needed. This chapter describes the basic
navigation of the AMI BIOS Setup Utility setup screens.
Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and
might not be recorded in this manual. Contact your service representative to obtain the latest BIOS
release.
Starting BIOS Setup Utility
To enter the AMI BIOS Setup Utility screens, press the <Delete> key while the system is booting
up.
Note: In most cases, the <Delete> key is used to invoke the AMI BIOS setup screen. There are a
few cases when other keys are used, such as <F1>, <F2>, etc.
Each main BIOS menu option is described in this manual. The Main BIOS setup menu screen has
two main frames. The left frame displays all the options that can be configured. Grayed-out
options cannot be configured. Options in blue can be configured by the user. The right frame
displays the key legend. Above the key legend is an area reserved for a text message. When an
option is selected in the left frame, it is highlighted in white. Often a text message accompanies it.
A "> " indicates a submenu. Highlighting such an item and pressing the <Enter> key will open the
list of settings within that submenu.
007-5683-001
55
7: BIOS
Note: The AMI BIOS has default text messages built in. These text messages my be included,
omitted, or changed across BIOS releases.
The AMI BIOS Setup Utility uses a key-based navigation system called "hot keys". Most of the
AMI BIOS setup utility "hot keys" can be used at any time during the setup navigation process.
These keys include <F1>, <F10>, <Enter>, <ESC>, arrow keys, etc.
Note: Options printed in Bold are default settings.
How To Change the Configuration Data
The configuration data that determines the system parameters may be changed by entering the
AMI BIOS Setup utility. This Setup utility can be accessed by pressing <Del> at the appropriate
time during system boot.
Starting the Setup Utility
Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the memory
is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility.
From the main menu, you can access the other setup screens. An AMI BIOS identification string
is displayed at the left bottom corner of the screen below the copyright message.
!
56
Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue.
Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall the
manufacturer be liable for direct, indirect, special, incidental, or consequential damages
arising from a BIOS update. If you have to update the BIOS, do not shut down or reset the
system while the BIOS is updating. This is to avoid possible boot failure.
007-5683-001
Main Menu
Main Menu
When you first enter AMI BIOS Setup Utility, you will see the Main Menu screen. You can
always return to the Main Menu by selecting the Main tab on the top of the screen with the arrow
keys.The Main Menu screen provides you with a system overview, which includes the version,
built date and ID of the AMIBIOS, the type, speed and number of the processors in the system and
the amount of memory installed in the system.
System Time/System Date
You can edit this field to change the system time and date. Highlight System Time or System Date
using the <Arrow> keys. Enter new values through the keyboard. Press the <Tab> key or the
<Arrow> keys to move between fields. The date must be entered in DAY/MM/DD/YYYY format.
The time is entered in HH:MM:SS format. Please note that time is in a 24-hour format. For
example, 5:30 A.M. appears as 05:30:00 and 5:30 P.M. as 17:30:00.
CPU Configuration
This displays static information on the Module Version, AGESA Version, Physical
Count and Logical Count for the system's processor(s) and clock.
CPU Information
This setting is used to select which physical CPU's information to display. Options include
Processor 0 or Processor 1. The information for the selected processor includes Processor
number, Revision, Cache L1/L2/L3, Speed, NB CLK, Able to
Change Frequency and uCode Patch Level.
Note: Zero is always the "Boot Strap Processor" or main CPU with all others being "Application
Processors".
GART Error Reporting
This option should remain disabled for normal operation. The driver developer may enable this
option for testing purposes. Options are Enabled or Disabled.
007-5683-001
57
7: BIOS
Microcode Update
This setting Enables or Disables microcode updating.
Secure Virtual Machine Mode
This setting is used to Enable or Disable SVM.
Power Now
This setting is used to Enable or Disable the AMD Power Now feature.
ACPI SRAT Table
This option Enables or Disables the building of the ACPI SRAT Table.
Clock Spread Spectrum
This option should remain Disabled for normal operation. The driver developer may enable it for
testing purposes.
IDE Configuration
Onboard PCI IDE Controller
This setting allows you to set the options for the PCI IDE controller. Options include Disabled,
Primary, Secondary or Both.
Primary/Secondary/Third IDE Master/Slave
LBA/Large Mode
LBA (Logical Block Addressing) is a method of addressing data on a disk drive. The options are
Disabled and Auto.
58
007-5683-001
Main Menu
Block (Multi-Sector Transfer)
Block mode boosts IDE drive performance by increasing the amount of data transferred. Only 512
bytes of data can be transferred per interrupt if block mode is not used. Block mode allows
transfers of up to 64 KB per interrupt. Select "Disabled" to allow the data to be transferred from
and to the device one sector at a time. Select "Auto" to allows the data transfer from and to the
device occur multiple sectors at a time if the device supports it. The options are Auto and
Disabled.
PIO Mode
PIO (Programmable I/O) mode programs timing cycles between the IDE drive and the
programmable IDE controller. As the PIO mode increases, the cycle time decreases. The options
are Auto, 0, 1, 2, 3, and 4. Select Auto to allow BIOS to auto detect the PIO mode. Use this value
if the IDE disk drive support cannot be determined. Select 0 to allow BIOS to use PIO mode 0,
which has a data transfer rate of 3.3 MBs. Select 1 to allow BIOS to use PIO mode 1, which has
a data transfer rate of 5.2 MBs. Select 2 to allow BIOS to use PIO mode 2, which has a data
transfer rate of 8.3 MBs. Select 3 to allow BIOS to use PIO mode 3, which has a data transfer rate
of 11.1 MBs. Select 4 to allow BIOS to use PIO mode 4, which has a data transfer rate of 16.6
MBs. This setting generally works with all hard disk drives manufactured after 1999. For other
disk drives, such as IDE CD-ROM drives, check the specifications of the drive.
DMA Mode
Selects the DMA Mode. Options are Auto, SWDMA0, SWDMA1, SWDMA2, MWDMA0.
MDWDMA1, MWDMA2, UDMA0. UDMA1, UDMA2, UDMA3, UDMA4 and UDMA5.
(SWDMA=Single Word DMA, MWDMA=Multi Word DMA, UDMA=UltraDMA.)
S.M.A.R.T.
Self-Monitoring Analysis and Reporting Technology (SMART) can help predict impending drive
failures. Select "Auto" to allow BIOS to auto detect hard disk drive support. Select "Disabled" to
prevent AMI BIOS from using the S.M.A.R.T. Select "Enabled" to allow AMI BIOS to use the
S.M.A.R.T. to support hard drive disk. The options are Disabled, Enabled, and Auto.
32-Bit Data Transfer
Select "Enabled" to activate the function of 32-Bit data transfer. Select "Disabled" to deactivate
the function. The options are Enabled and Disabled.
007-5683-001
59
7: BIOS
Hard Disk Write Protect
Use this setting to Enable or Disable hard disk write protection for your system. This is effective
only if the device is accessed through the BIOS.
IDE Detect Timeout (Sec)
Use the +/- keys to adjust and select the time out for detecting ATA/ATAPI devices. The default
value is 35.
ATA(PI) 80-Pin Cable Detection
This option selects the mechanism used for detecting the installation of an 80-pin ATA(PI) cable.
Options include Host & Device, Host or Device.
SuperI/O Configuration
Serial 1 Address
This option specifies the base I/O port address and Interrupt Request address of serial port 1.
Select "Disabled" to prevent the serial port from accessing any system resources. When this option
is set to Disabled, the serial port physically becomes unavailable. Select "3F8/IRQ4" to allow the
serial port to use 3F8 as its I/O port address and IRQ 4 for the interrupt address. Options include
Disabled, 3F8/IRQ4, 3E8/IRQ4 and 2E8/IRQ3
Serial 2 Address
This option specifies the base I/O port address and Interrupt Request address of serial port 2.
Select "Disabled" to prevent the serial port from accessing any system resources. When this option
is set to "Disabled", the serial port physically becomes unavailable. Select "2F8/IRQ3" to allow
the serial port to use 2F8 as its I/O port address and IRQ 3 for the interrupt address. Options
include Disabled, 2F8/IRQ3, 3E8/IRQ4 and 2F8/IRQ3.
Serial Port Mode
This sets the serial port mode for your system. Options include Normal, IrDA and ASK IR.
60
007-5683-001
Main Menu
Restore on AC Power Loss
This sets the action that occurs when an AC power loss occurs. Options include Power Off, Power
On and Last State.
Watch Dog Timer
This sets the Watch Dog Timer. Options include Enabled or Disabled.
Advanced ACPI Configuration
ACPI Version Features
Use this setting the determine which ACPI version to use. Options are ACPIv1.0, ACPI v2.0 and
ACPI v3.0.
ACPI APIC Support
Determines whether to include the ACPI APIC table pointer in the RSDT
pointer list. The available options are Enabled and Disabled.
AMI OEMB Table
This setting specifies whether to include the OEMB table pointer to the R(X) SOT pointer lists.
Options include Enabled or Disabled. Headless Mode Use this setting to Enable or Disable
headless operation mode through ACPI.
IPMI Configuration
This menu shows static information about the IPMI firmware revision and status of the BMC, as
well as options for IPMI configuration.
View BMC System Event Log
Pressing the Enter key will open the following settings. Use the "+" and "-" keys to navigate
through the system event log.
007-5683-001
61
7: BIOS
Clear BMC System Event Log
Selecting this and pressing the Enter key will clear the BMC system event log.
Set LAN Configuration
Use the "+" and "-" keys to choose the desired channel number. This displays Channel Number
and Channel Number Status information.
IP Address
This submenu sets the IP address source as either Static or DHCP. Selecting Static allows you to
manually set the IP Address, Subnet Mask and Gateway Address.
In the field provided here enter the IP address in the decimal form of xxx.xxx.xxx.xxx with xxx
having a value of less than 256 and in decimal form only. The IP address and current IP address
in the BMC are shown.
MAC Address
In the field provided here enter the MAC address in the hex form of xx.xx. xx.xx.xx.xx with xx in
hex form only. The current MAC address in the BMC is shown.
Subnet Mask
In the field provided here enter the Subnet address in the decimal form of xxx.xxx.xxx.xxx with
xxx having a value of less than 256 and in decimal form only. The current subnet address in the
BMC is shown.
Gateway Address
In the field provided here enter the Gateway address in the decimal form of xxx.xxx.xxx.xxx with
xxx having a value of less than 256 and in decimal form only. The current Gateway address in the
BMC is shown.
62
007-5683-001
Main Menu
MPS Configuration
MPS Revision
This option allows you to set the MPS revision for your system. Options include revision 1.1 and
1.4.
PCI Express Configuration
Relaxed Ordering
Enables or Disables PCI Express Device Relaxed Ordering in the system. Options include Auto,
Disabled or Enabled.
Extended Tag Field
When this option is enabled, it allows the device to use the 8-bit TAG field as a requester. Options
include Auto, Disabled or Enabled.
No Snoop
This option enables or disables the PCI Express device No Snoop option. Options include Auto,
Disabled or Enabled.
Active State Power Management
This setting allows you to Enable or Disable the PCI Express L0s and L1 link power states.
Extended Sync
If this option is enabled, it allows the generation of extended synchronization patterns. Options
include Auto, Disabled or Enabled.
007-5683-001
63
7: BIOS
Remote Access Configuration
Remote Access
Use this option to Enable or Disable Remote Access in your system. If enabled, the settings below
will appear.
Serial Port Number
Use this setting to select the serial port for console redirection. Options include COM1, COM2 or
COM3*. The displayed base address and IRQ for the serial port changes to reflect the selection
you make. Note: Make sure the selected port is enabled.
Serial Port Mode
Selects the serial port settings to use. Options are (115200 8, n, 1), (57600 8,n, 1), (38400 8, n, 1),
(19200 8, n, 1) and (09600 8, n, 1).
Flow Control
Selects the flow control to be used for console redirection. Options are None, Hardware and
Software.
Redirection After BIOS POST
Options are Disable (no redirection after BIOS POST), Boot Loader (redirection during POST and
during boot loader) and Always (redirection always active). Note that some OS's may not work
with this set to Always.
Terminal Type
Selects the type of the target terminal. Options are ANSI, VT100 and VTUTF8.
VT-UTF8 Combo Key Support
Allows you to Enable or Disable VT-UTF8 combination key support for ANSI/VT100 terminals.
64
007-5683-001
Main Menu
Sredir Memory Display Delay
Use this setting to set the delay in seconds to display memory information. Options are No Delay,
1 sec, 2 secs and 4 secs.
USB Configurations
This submenu displays the Module Version and lists the USB devices that are enabled as well as
the following options.
Legacy USB Support
Select "Enabled" to enable the support for USB Legacy. Disable Legacy support if there are no
USB devices installed in the system. "Auto" disabled Legacysupport if no USB devices are
connected. The options are Disabled, Enabled and Auto.
USB 2.0 Controller Mode
Use this setting to configure the USB 2.0 Controller in either Hi-Speed (480 Mps) or Full Speed
(12 Mps) mode.
BIOS EHCI Hand Off
This is a workaround for OS's without EHCI hand-off support. The EHCI ownership change
should be claimed by the EHCI driver. Options are Enabled or Disabled.
Legacy USB1.1 HC Support
This option Enables or Disables support for USB1.1 HC devices.
USB Mass Storage Device Configuration
This submenu is used to configure USB mass storage class devices.
USB Mass Storage Reset Delay
Use this option to set the number of seconds POST waits for the USB mass storage device after
the Start Unit command. Options include 10, 20, 30 and 40 seconds.
007-5683-001
65
7: BIOS
Emulation Type
This sets the emulation type for USB mass storage devices. If Auto, USB devices less than 530
MB will be emulated as Floppy and remaining as Hard Disk drive. The Force FDD option can be
used to force a HDD formatted drive to boot as an FDD (example: ZIP drive). Options include
Auto, Floppy, Forced FDD, Hard Disk and CD-ROM.
System Health Monitor
CPU Overheat Temperature
This setting allows you to specify the type of alarm for CPU overheating. Options include The
Early Alarm and The Default Alarm. Other items in the submenu are systems monitor displays
for the following information:
CPU1 Temperature, CPU2 Temperature, CPU3 Temperature, CPU4 Temperature, System
Temperature, Fan 1-9 Reading, Chipset FAN1-2, CPU1 VCore, CPU2 VCore, CPU3 VCore,
CPU4 VCore, 3.3V Vcc (V), + 5Vin, +12V Vcc (V), CPU1~4 DIMM Voltage, Chipset SR56x0
Voltage, 3.3V standby, Battery Voltage
System Fan Monitor
This submenu contains lists the system fans and contains RPM information for them.
Fan Speed Control Modes
This submenu allows you to determine how the system will control the speed of the on-board fans.
The options are Full Speed/FS (Max Cooling), Performance/ PF (Better Cooling), Balanced/BL
(Balance between performance and energy saving), Energy Saving/ES (Lower Power and Noise).
PCI/PNP Settings Menu
Clear NVRAM
Select Yes to clear NVRAM during boot-up. The options are Yes and No.
66
007-5683-001
Main Menu
Plug & Play O/S
Select Yes to allow the OS to configure Plug & Play devices. (This is not required for system boot
if your system has an OS that supports Plug & Play.) Select No to allow AMIBIOS to configure
all devices in the system.
PCI Latency Timer
This option sets the latency of all PCI devices on the PCI bus. Select a value to set the PCI latency
in PCI clock cycles. Options are 32, 64, 96, 128, 160, 192, 224 and 248.
Allocate IRQ to PCI VGA
Use this option to allocate IRQ to the PCI VGA card. Option include Yes and No. Selecting Yes
assigns IRQ to PCI VGA card if the card requests IRQ. Selecting No means the system will not
assign IRQ to the PCI VGA card even if the card requests IRQ.
Pallette Snooping
This option Enables or Disables Pallette Snooping. If enabled, the system informs the PCI devices
that an ISA graphics device is installed in the system so the card will function normally.
PCI IDE Busmaster
Use this setting to Enable or Disable BIOS enabled uses of PCI Busmastering for reading or
writing to IDE drives.
Offboard PCI/ISA IDE Card
Some PCI IDE cards may require this option to be set to the PCI slot number that is holding the
card. The Auto setting works for most PCI IDE cards. Options include Auto, PCI Slot 1,
PCI Slot 2, PCI Slot 3, PCI Slot 4, PCI Slot 5 and PCI Slot 6.
IRQ3 ~ IRQ15 Settings
These settings specify if IRQ is available to be used by PCI/PnP devices or is reserved for use by
legacy ISA devices. Options are Available or Reserved.
007-5683-001
67
7: BIOS
DMA Channel 0 ~ DMA Channel 7 Settings
These settings specify if a DMA Channel is available to be used by PCI/PnP devices or is reserved
for use by legacy ISA devices. Options are Available or Reserved.
Reserved Memory Size
This option specifies the size of the memory block reserved for legacy ISA devices. Options
include Disabled, 16k, 32k or 64k.
HotPlug Reserve I/O Port Size
This option specifies the size of the I/O port block to reserve for HotPlug or CardBus devices.
Options include Auto, 4K, 8K, 12K, 16K, 20K, 24K and 28K.
HotPlug Reserve Memory Size
This option specifies the size of the memory block to reserve for HotPlug or CardBus devices.
Options include Auto, 8M, 16M, 32M, 65M, 128MB, 256MB or 512MB.
HotPlug Reserve PFMemory Size
This option specifies the size of the prefetchable memory block to reserve for HotPlug or CardBus
devices. Options include Auto, 32M, 64M, 128MB, 256MB, 512MB, 1024M or 2048M.
Onboard NIC PXE Option ROM
This option Enables or Disables the onboard NIC PXE option ROM.
BIOS Settings Configuration
Quick Boot
If Enabled, this option will skip certain tests during POST to reduce the time needed for the system
to boot up. The options are Enabled and Disabled.
68
007-5683-001
Main Menu
Quiet Boot
If Disabled, normal POST messages will be displayed on boot-up. If Enabled, this display the
OEM logo instead of POST messages.
Add On ROM Display Mode
This option sets the display mode for Option ROM. The options are Force BIOS or Keep Current.
Bootup Num Lock
This option selects the power-on state for the NUM lock to either On or Off.
PS/2 Mouse Support
Use this option to select support for the PS/2 mouse. Options are Disabled, Enabled or Auto.
Wait for F1 if Error
This setting controls the system response when an error is detected during the boot sequence.
When enabled, BIOS will stop the boot sequence when an error is detected, at which point you
will need to press the F1 button to re-enter the BIOS setup menu. The options are Enabled and
Disabled.
Hit 'DEL' Message Display
Use this option to Enable or Disable the "Press DEL to run setup" message in POST.
Interrupt 19 Capture
Select Enabled to allow ROMs to trap Interrupt 19. The options are Enabled and Disabled.
Boot Device Priority
This feature allows you to prioritize the boot sequence from the list of available devices. A device
that is in parenthesis has been disabled in the corresponding type menu.
007-5683-001
69
7: BIOS
Hard Disk Drives
This feature allows you to specify the boot sequence from the list of available hard disk drives. A
device that is in parenthesis has been disabled in the corresponding type menu.
Removable Drives
This feature allows you to specify the boot sequence from the list of available removable drives.
A device that is in parenthesis has been disabled in the corresponding type menu.
CD/DVD Drives
This feature allows you to specify the boot sequence from the list of available CD/DVD drives. A
device that is in parenthesis has been disabled in the corresponding type menu.
Network Drives
This feature allows you to specify the boot sequence from the list of available network drives. A
device that is in parenthesis has been disabled in the corresponding type menu.
Security Settings Menu
AMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor
password must be set first.
Change Supervisor Password
Select this option and press <Enter> to access the sub menu, and then type in the password.
Change User Password
Select this option and press <Enter> to access the sub menu, and then type in the password.
Boot Sector Virus Protection
This option is near the bottom of the Security Setup screen. Select "Disabled" to deactivate the
Boot Sector Virus Protection. Select "Enabled" to enable boot sector protection. When "Enabled",
70
007-5683-001
Main Menu
AMI BIOS displays a warning when any program (or virus) issues a Disk Format command or
attempts to write to the boot sector of the hard disk drive. The options are Enabled and Disabled.
NorthBridge Configuration
Channel Interleaving
Selects the channel-interleaving memory scheme when this function is supported by the processor.
The options are Disabled or Auto.
Enable Clock to All DIMMs
This option allows you to Enable or Disable unused clocks to DIMMs even when memory slots
are not populated.
Memory Hole Remapping
When "Enabled", this feature enables hardware memory remapping around the memory hole.
Options are Enabled and Disabled.
CS Sparing Enable
This option will reserve a spare memory rank in each node when enabled. Options are Enable and
Disable.
Power Down Enable
This option enables or disables DDR power down mode. Options are Auto, Enabled and Disabled.
Power Down Mode
This sets the DDR power down mode. Options are Auto, Channel and Chip Select.
DRAM Parity Enable
This sets the DRAM Parity Enable to either Auto, Enabled and Disabled.
007-5683-001
71
7: BIOS
Bank Swizzle Mode
This sets the Bank Swizzle Mode to either Auto, Enabled and Disabled.
ECC Configurations
ECC Mode
This submenu sets the level of ECC protection. Options include Disabled, Basic, Good, Super,
Max and User. Selecting User activates the other options for user setting.
Note: The "Super" ECC mode dynamically sets the DRAM scrub rate so all of memory is
scrubbed in 8-hours.
DRAM ECC Enable
This setting allows hardware to report and correct memory errors automatically, maintaining
system integrity. Options are Enabled or Disabled.
DRAM Scrub Redirect
This setting allows the system to correct DRAM ECC errors immediately when they occur, even
if background scrubbing is off. Options are Enabled or Disabled.
4-Bit ECC Mode
Allows the user to enabled 4-bit ECC mode (also known as ECC Chipkill). Options are Enabled
and Disabled.
DRAM BG Scrub
Corrects memory errors so later reads are correct. Options are Disabled and various times in
nanoseconds and microseconds. The default is 163.8us.
Data Cache BG Scrub
Allows L1 cache RAM to be corrected when idle. Options are Disabled and various times in
nanoseconds and microseconds. The default is 2.56us.
72
007-5683-001
Main Menu
L2 Cache BG Scrub
Allows L2 cache RAM to be corrected when idle. Options are Disabled and various times in
nanoseconds and microseconds. The default is 2.56us.
L3 Cache BG Scrub
Allows L3 cache RAM to be corrected when idle. Options are Disabled and various times in
nanoseconds and microseconds. The default is 2.56us.
DRAM Timing Configurations
DRAM Timing Config
This setting specifies the DRAM timing configuration. Options are Auto and Manual.
Memory Timing Parameters
This selects which node's timing parameters to display. Options are CPU Node 0 or CPU Node 1.
SouthBridge Configuration
A15 ECOs
This setting Disables or Enables A15 ECOs.
Port 0 ~ Port 5 ESP
These settings allow you to set Port 0 through Port 5 ESP help as either ESP or ISP.
Dis #THRMTRIP before KBRst
This setting allows you to Enable or Disable Dis #THRMTRIP before KBRst.
007-5683-001
73
7: BIOS
SATA-IDE Ports Auto Clk Ctrl
This option, when enabled, will shutdown the clocks for unused SATA ports in IDE mode,
IDE->AHCI and IDE->AMD_AC modes. This will enable some power savings, but please note
that if you shutdown the clock then the hotplug for that port will not work. Options are Disabled
or Enabled.
SATA-AHCI Ports Auto Clk Ctrl
This option, when enabled, will shutdown the clocks for unused SATA ports in AHCI and
AMD-AHCI modes. This will enable some power savings, but please note that if you shutdown
the clock then the hotplug for that port will not work. Options are Disabled or Enabled.
SATA Port 0 ~ Port 5 Mode
This setting forces the SATA selected SATA port to run at GEN1 mode if this option is set to
GEN1. Setting this option to Auto will leave the port to run at the default mode.
OHCI/EHCI HC Device Functions
These settings allow you to either Enable or Disable functions for OHCI or EHCI bus devices.
On Chip SATA Channel
This setting allows you to Enable or Disable the On-Chip SATA channel.
On Chip SATA Type
Use this setting to set the On Chip SATA type. Options include Native IDE, RAID, AHCI and
Legacy IDE.
SATA IDE Combined Mode
This setting allows you to Enable or Disable the SATA IDE combined mode.
PATA Channel Configuration
This allows you to set PATA channel configuration. Options include SATA as Primary or SATA
as secondary.
74
007-5683-001
Main Menu
Power Saving Features
Use this option to Enable or Disable power down saving features in the Southbridge chipset. This
feature should be enabled for mobile systems and disabled for desktop systems. See the AMD
SB700 Power Saving document for more details.
Port 02 ~ Port 13 Features
This submenu allows you to set the features for Ports 02 through 13 in the system. Each port
submenu allows you to define the same settings below.
Gen 2 High Speed Mode
This setting allows you to set the Gen 2 high-speed mode. Options include Auto, Disabled,
Software Initiated and Advertised RC.
Link ASPM
Use this setting to configure the Link ASPM. Options include Disabled, L0s, L1, L0s & L1, L0
Downstream and L0 Downstream + L1.
Note: For ATI GFx Card M2x use L1 only. For ATI GFx Card M5x use both L0s & L1.
Link Width
Use this setting to configure the Link Width. Options include Auto, x1, x2, x4, x8 and x16.
Slot Power Limit, W
Use this setting to configure the Slot Power Limit power. The user can adjust this value using the
+ and - keys. The default is 75.
Compliance Mode
This setting allows you to Enable or Disable the Compliance Mode.
007-5683-001
75
7: BIOS
Remap Port Device Number
This setting allows you remap the Port Device number. Options include Auto and port numbers
between 2 and 13.
L1 Immediate ACK
This setting allows you to Enable or Disable L1 ACK. When enabled, the L1 will be ACK'd
immediately.
Lane Reversal
Use this setting to Enable or Disable Lane Reversal.
Hot Plug Support
Use this setting to set Hot Plug Support. Options include Disabled and Native.
NB-SB Port Features
NB-SB Link APSM
Use this to set the NB-SB Link ABSM. Options include L1 and Disabled.
Link Width
This setting allows you to set the Link Width for the NB-SB port. Options include Auto, x1, x2
and x4.
NP NB-SB VC1 Traffic Support
Use this setting to Disable or Enable NP NB-SB VC1 traffic support.
Compliance Mode
Use this setting to Enable or Disable Compliance Mode for the NB-SB port.
76
007-5683-001
Main Menu
GPP1 ~ GPP3b Core Settings
These submenus allow you to specify GPP core settings. Each submenu allows you to define the
same settings listed below.
Core Configuration
This setting allows you to configure core configuration. Options include Auto, 1x16 and 2x8.
Powerdown Unused Lanes
This setting allows you to Enable or Disable the powerdown of unused lanes.
Turnoff Off PLL During L1/L23
This setting allows you to Enable or Disable turning off PLL during L1/L23.
TX Drive Strength
Use this setting to configure TX drive strength. Options include Auto, 26mA, 20mA, 22mA and
24mA.
TXCLK Clock Gating in L1
Use this setting to Enable or Disable the TXCLK clock gating in L1.
LCLK Clock Gating in L1
Use this setting to Enable or Disable the LCLK clock gating in L1.
SB Core Settings
TX Drive Strength
Use this setting to configure TX drive strength. Options include Auto, 26mA, 20mA, 22mA and
24mA.
007-5683-001
77
7: BIOS
TXCLK Clock Gating in L1
Use this setting to Enable or Disable the TXCLK clock gating in L1.
LCLK Clock Gating in L1
Use this setting to Enable or Disable the LCLK clock gating in L1.
Debug Options
Peer to Peer Among GPP1/GPP2
Use this setting enable or disable Peer to Peer among GPP1/GPP2. Options include Auto, Enabled
and Disabled.
Reset to Training Delay (ms)
Use the +/- keys to change the reset to training delay time setting. The default is 50.
Receiver Detection Pooling (ms)
Use the +/- keys to change the receiver detection pooling time setting. The default is 180.
Hide Unused PCIE P2P Bridges
Use this setting to Enable or Disable the hiding of unused PCIE P2P bridges.
GFX Card Workaround
This setting allows you to Enable or Disable the GFX Card workaround on your system.
Debug Bus Configuration
PCIE Debug Bus
This setting Enables or Disables PCIE debugging of the bus.
78
007-5683-001
Main Menu
Hyper Transport Configuration
HT Extended Address
This setting allows you to Enable or Disable the HT extended address. Options include Enabled,
Disabled and Auto.
HT3 Link Power State
This setting allows you to configure the HT3 Link power state. Options include Auto, LS0, LS1,
LS2 and LS3.
Unit ID Clumping
Use this setting to configure Unit ID clumping. Options include Disabled, Auto, UnitID 2/3,
UnitID B/C and UnitID 2/3 & B/C.
HT Link Tristate
This setting allows you to configure the HT Link Tristate. Options include Auto, Disabled,
CAD/CTL and CAD/CTL/CLK.
NB Deemphesis Level
Use this to set the NB deemphesis level. Options include Disabled, 0.4 dB, 1.32 dB, -2.08dB, 3.1
dB, 4.22 dB, 5.50 dB and 7.05 dB.
IOMMU
This setting is used to disable or set the GART size in systems without AGP. Options include AGP
Present, Disabled, 32 MB, 64 MB, 128 MB, 256 MB, 512 MB and 1 GB.
Primary Video Controller
Use this setting to specify the primary video controller boot order. Options include
PCIE-GPP1-GPP2-GPP3a-PCI, PCIE-GPP2-GPP1-GPP3a-PCI,
PCIE-GPP3a-GPP1-GPP2-PCI or PCI-PCIE-GPP1-GPP2-GPP3a.
007-5683-001
79
7: BIOS
PCI Spread Spectrum
Use this setting to Enable or Disable PCI Spread Spectrum in the system.
Debug Options
Memory Decod on Sec. 6FX
Use this option to set memory decod on sector 6FX. Options are Disabled or Force.
IOC Peer-to-Peer Mode
Use this option to set the IOC peer-to-peer mode. Options include Auto, Default, Mode1 and
Mode2
Northbridge Interrupt Pin
This option Enables or Disables the Northbridge Interrupt Pin.
Exit Menu
Select the Exit tab from AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.
Save Changes and Exit
When you have completed the system configuration changes, select this option to leave BIOS
Setup and reboot the computer, so the new system configuration parameters can take effect. Select
Save Changes and Exit from the Exit menu and press <Enter>.
Discard Changes and Exit
Select this option to quit BIOS Setup without making any permanent changes to the system
configuration and reboot the computer. Select Discard Changes and Exit from the Exit menu and
press <Enter>.
80
007-5683-001
Main Menu
Discard Changes
Select this option and press <Enter> to discard all the changes and return to AMI BIOS Utility
Program.
Load Optimal Defaults
To set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then
Select "OK" to allow BIOS to automatically load the Optimal Defaults as the BIOS Settings. The
Optimal settings are designed for maximum system performance, but may not work best for all
computer applications.
Load Fail-Safe Defaults
To set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. The
Fail-Safe settings are designed for maximum system stability, but not maximum performance.
007-5683-001
81
Appendix A
A. BIOS Error Codes
During Power-On Self-Test (POST) routines, which are performed each time the system is
powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
The error messages normally appear on the screen.
Fatal errors are those which will not allow the system to continue the boot-up procedure. If a fatal
error occurs, you should consult with your system manufacturer for possible repairs.
These fatal errors are usually communicated through a series of audible beeps. The numbers on
the fatal error list (see Table A-1) correspond to the number of beeps for the corresponding error.
Table A-1
007-5683-001
BIOS Error Codes
Beep Code
Error Message
Description
1 beep
Refresh
Circuits have been reset.(Ready to power up)
5 short beeps + 1 long beep
Memory error
No memory detected in the system
1 long beep +8 short beeps
Display error or memory
read/write error
Video error - adapter missing or with faulty
memory
83
Appendix B
B. System Operating and Regulatory Overview
This appendix provides basic environmental operating requirements and regulatory information
for the server.
Operating Environment
Operating Temperature: 0º to 35º C (32º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 20% to 95% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22
Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking
(Europe)
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate
warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells.
“Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate”
007-5683-001
85