“We didn’t invent clean power, we merely perfected it!” INTRODUCTION Always On™ UPS Systems Canada Inc. employs over 100 years of experience in the design and manufacture of high quality UPS systems and Power Conditioning Products. Always On™ UPS systems incorporate highly efficient Low-Pass Series and TVSS filters, which provide the protection required by today’s automated world for all critical environments. We take a personal interest to ensure that our UPS systems and Power Quality Products will continue to be manufactured to the highest degree of quality in our ISO-9001 Certified facilities. Using Always On™ UPS products reduces the need for additional noise, spike and transient filters, as we design this protection into every system we build. Always On™ is the only UPS manufacturer that incorporates input and output filters providing all 10 levels of electrical protection. Always On™ products, by increasing the reliability and life of your electronic equipment, increase up-time, which allows for increased production resulting in increased profits. All our products are manufactured in ISO-9001 Certified facilities, and are environmentally friendly, so much so that we use “GES” (Green Energy Systems) as part of our model identification. Zero tolerance in our Quality Assurance tests at all levels of production continues to eliminate failures in the field. We presently enjoy “0” UPS failures in the field and *DOA’s are non-existent. Always On™ UPS systems are approved for use by DND Canada, the US Military, US educational departments, engineering consultants, the Canadian Coast Guard, GEAC, Ballard Generation Systems, health authorities across North America, RCMP Forensics, the pulp and paper industry, Syncrude, Suncor and numerous OEM’s across North America. When you purchase Always On™ products, you receive: CANADIAN MADE, ENERGY EFFICIENT, HIGH QUALITY COST EFFECTIVE PRODUCTS. * Dead On Arrival Available on our web site: www.alwayson.com Product Information and Specifications UPS Selector Manufacturer Cross-Reference UPC Order Code Selector Inside sales and engineering support is available on our toll-free telephone lines: 1-877-259-2976 (Sales ext. 451). E-mail for support departments: [email protected], [email protected] Version 13, 01, 23 Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 Limousin II & The “Bull” Always On™’s LIMOUSIN Series are transformer based UPS’s which provide lightning, surge, spike, transient and noise protection and feature constant Automatic Voltage Regulation (AVR) and blackout protection. They are designed for the home/office user to provide the maximum protection at a competitive price. The Bull is not any ordinary power bar; with its automatic voltage regulation (AVR) and its triple protection (spikes, noise, and transient suppression), it can handle applications not suitable for other power bars. Page 6 L Series (line-interactive true sine wave output) Always On™’s L Series are line interactive UPS systems with a true sine wave output on all modes of operation. They are ideal for commercial and industrial applications and range in size from 800VA to 3kVA. All L Series systems provide voltage regulation, noise, surge and spike protection, serial communication interface, network and modem protection, extended runtime options and additional communication interfaces. Page 7 N Series 1 ∅ (dual conversion on-line) Always On™’s N Series are dual conversion true on-line UPS systems which provide the attached loads with isolation from the utility or generator supply. At all times, the loads are supplied power from the inverter, which is fed by the batteries and is designed for critical applications. The wide input range (gen. mode) is designed into these systems while maintaining output at 120VAC at 60Hz +/- 2%. The single phase systems are available from 700VA to 3kVA. Page10 TN Series 1 ∅ (dual conversion on-line) Always On™’s TN Series are dual conversion true on-line UPS systems which provide the attached loads with isolation from the utility or generator supply. At all times, the loads are supplied power from the inverter, which is fed by the batteries and is designed for critical applications. The wide input range (gen. mode) is designed into these systems while maintaining output at various voltage and frequency configurations. The single phase systems are available from 5kVA to 20kVA. Page 13 NX Series 3 ∅ (dual conversion on-line) Always On™’s NX Series are dual conversion true on-line UPS systems which provide the attached loads with isolation from the utility or generator supply and are designed for all critical applications. These critical loads are supplied power from the inverter, which is fed by the batteries. The NX Series is designed with a large input range and incorporates an output isolation transformer. These UPS systems are available from 10kVA to 320kVA with three phase input and three phase or single phase output with multiple voltage configurations. Page 15 Software Always On™ offers several different communication and connection options to manage your UPS. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 4 Page 24 NFC Series Frequency Converters (50, 60, or 400Hz selectable output frequency) Always On™’s NFC Series Frequency Converters incorporate all the features of our dual conversion true on-line UPS systems as well as the ability to lock the output frequency to the three major standards. The dual conversion technology allows the load to be supplied with 50Hz, 60Hz, or 400Hz, independent of the input. The NFC Series is designed with large input range and incorporates an isolation transformer. These NFC systems are available from 10kVA to 250kVA with three phase input and three phase output. Page 25 Electrical Service Entrance TVSS Filter (ESE) The Always On™ “ESE” TVSS filter is designed to protect your power grid. Installed at the power panel, it provides protection against externally and internally produced power aberrations, massive impulses, lightning induced effects and interference associated with low frequency harmonics and situations caused by accidents and/or failures in the electrical utility system. It is totally compatible with all operating loads including high frequency power supplies and constant current loads controlled by electronic switches. Page 27 PLC Low-Pass Series Filter Always On™’s PLC filters are designed to provide noise, surge, spike, transient, and overload protection to PLC power supplies and peripherals. Two different types are available; AC only and AC/DC with data line protection to ensure clean operation and transfer to all I/O interfaces, peripherals and power supplies. All systems include an onboard resettable breaker, and a three colour LED for easy operation identification and diagnostics. Page30 Engineered Solutions Always On™ provides engineered solutions. From sensitive telecommunication equipment to oil rig conditions, we can provide solutions to suit the needs of your environment. Page 32 TF/ILF (Isolating Line Filter) The Always On™ TTF/ILF combines a Low-Pass Series filter with a toroidal isolation transformer. This unit provides attenuation of both normal and common mode noise and eliminates any troublesome constant voltage which may exist between neutral and ground in some electrical configurations. It is totally compatible with all operating loads, including high frequency switching power supplies. It re-establishes the “0” volts ground reference point on the secondary. Page 33 Emergency Lighting (Aurora and Borealis Series) Always On™ ELI’s are designed for installation between your AC power supply (utility or generator) and your lighting equipment. It provides power to your equipment during major power events such as blackouts and brownouts, over-voltage and under-voltage conditions. The ELI provides a consistent supply of regulated AC power during these power events, allowing you to ensure safety and lighting for the period required. Page 34 Genie (AC Smart Distribution Panel / Cabinet powered by UPS) The “Genie” is designed to supply AC power while protecting the multiple critical loads supplied by the distribution (Genie) panel. The “Genie” incorporates the Always On™ SDB breaker, which is specifically designed to clear in less than 1 second, eliminating multiple load trips. The “Genie” replaces the required retrofitting of standard panels with fast-blow fuses. A communication interface allows for a remote attendant. Page 39 Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 5 Home/Office/Commercial/Industrial Limousin II LIMOUSIN II United Nation Standard Product & Service Code # 39121011 MODEL GENERAL LIMOUSIN II Capacity 600VA UPC Order Code 825433 00111 Voltage INPUT 120V nominal (220V option), +/-25% Frequency 50 or 60Hz +/- 5% (auto sensing) Input socket (1) IEC 320 Voltage (on battery) Frequency (on battery) OUTPUT +/-10% of nominal Waveform (On Battery) Pulse Width Modulated (PWM) 4 milliseconds, including detection Receptacles (3) NEMA 5-15R (120V) Spike Protection PROTECTION and FILTERING Overload Protection Short Circuit Type BATTERY 6 hours (to 90% of full capacity) Back up Time (Full load) 10-30 minutes RS-232 LED Display Normal / Backup / Overload On Battery, Low Battery, Overload Temperature range ENVIRONMENT Humidity Audible Noise PHYSICAL DATA Fuse protection or immediate shutdown Sealed, maintenance-free lead acid Audible Alarms SAFETY APPROVAL 480 joules, 2ms 110% for 60 seconds and 130% for 3 seconds Typical Recharge Time Communications INTERFACE 50 or 60Hz +/- 0.5Hz Auto Voltage Regulation Transfer Time The Limousin II is a transformer-based UPS that provides lightning, surge, spike, transient, and noise protection. The Limousin II Series provides for constant Automatic Voltage Regulation (AVR) and blackout protection. It is designed for the home/office user to provide the maximum protection at a competitive price. A shutdown/control software package, communication cable and telephone/network protection are all available with the Limousin II. 120VAC nominal +/-5% Simulated sine wave o 0-40 C 0-95% non-condensing <40dBA (1 meter from surface) Safety cUL, UL1778, CSA C22.2 EMI / RFI FCC PART 15 CLASS B Surge / Transient IEEE C62.41 CAT.A Net weight kg(lbs) 6.2(13.6) Shipping weight kg(lbs) 6.7(14.9) Dimension(mm)WxDxH 97x320x135 Specifications are subject to change without notice to reflect upgrades and improvement in technology. Commercial Power Bar “Bull” Commercial Power Bar Voltage Regulation, Noise, Spike and Transient Protection “BULL” Power Bar United Nation Standard Product & Service Code # 39121009 Error! Not a valid link.Specifications are subject to change without notice to reflect upgrades and improvement in technology. ADVANCED FEATURES: The Bull provides voltage regulation / variable input voltage (+-10% output), electrical noise, spike and surge protection, and IC chip design and it operates at 95%+ efficiency. It features overload protection with a resettable breaker and output short protection with a resettable breaker, as well as network protection and fax / modem protection. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 6 Communications/Industrial “L” Series (TRUE SINE WAVE) Rackmount DESCRIPTION: Always On™’s L Series are line-interactive UPS systems with a true sine wave output in all modes. These systems are ideal for commercial and light industrial applications and range in size from 800VA to 3kVA. All systems provide voltage regulation, a serial communication interface, network and modem protection, extended runtime options and additional communication interfaces. APPLICATIONS: Among other applications, the L Series can be applied to LAN file servers, personal computers, networks and workstations, Automatic Teller Machines, telecommunications equipment, POS equipment, robotics, test equipment, PLC’s, security and emergency systems and applications where additional runtime or SNMP are required. ADVANCED FEATURES: SMART “BOOST AND BUCK” LINE CONDITIONING: The Always On™ transformer-based built-in line conditioning provides stable voltage when the utility supply fluctuates. LIGHTNING, NOISE, SPIKE AND TRANSIENT PROTECTION: The L Series offers lightning and surge protection, common mode and normal mode noise protection and Low-Pass Series filters on the input and output. NETWORK AND MODEM PROTECTION: The Always On™ high end multi-component design provides ultimate protection and RJ11 and RJ45 connectivity. INTELLIGENT COMMUNICATIONS INTERFACE: RS-232 or dry contact interface ports act as the communication link between the computer and the UPS. Various management software is available. COLD START: The cold start function allows start from battery when AC is not present. AUTO RESTART: This feature allows the UPS to restart automatically when the utility becomes available, provided the UPS has been shutdown due to an extended blackout. AUTO FREQUENCY DETECTION: The automatic frequency sensing function will match the input and output frequency. BATTERY REPLACEMENT: User replaceable battery. SNMP ADAPTER: An optional SNMP adapter allows your network to easily manage the UPS, including remote control and status monitoring. CHARGING CURRENT WITH LOW RIPPLE AND LOW HARMONICS A control circuit is used to provide a strict sine wave with low ripple and little harmonic distortion from the charging current. VALUE ADDED: Power Management and Shutdown Software, Communication Cable, Power Cable. USB OPTION: Available at time of order. EXTENDED RUNTIME OPTIONS: Additional battery banks are available for all models. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 7 “L” Series (TRUE SINE WAVE) United Nation Standard Product & Service Code # 39121011 Specification GENERAL MODEL NO. MAXIMUM CAPACITY UPC ORDER CODE GES-801L 800VA / 520W 825433 22100 NOMINAL VOLTAGE INPUT VOLTAGE RANGE FREQUENCY RANGE NOMINAL VOLTAGE AUTO VOLTAGE REGULATION CURRENT 6.6A FREQUENCY OUTPUT POWER FACTOR WAVE FORM (ON BATTERY) LOAD CREST FACTOR TRANSFER TIME OUTLETS 4 BATTERY TYPE BATTERY QUANTITY VOLTAGE 2 24VDC RECHARGE TIME FULL LOAD BACKUP POWER TIME HALF LOAD PENTIUM & 17" MON ≥ 8 MIN. ≥ 20 MIN. ≥ 41 MIN. EXTENDED RUN TIME OUTPUT SHORT ABNORMAL VOLTAGE PROTECTION 4x2 48VDC ≥ 8 MIN. ≥ 25 MIN. ≥ 90 MIN. COMMON & NORMAL MODE NOISE SUPPRESSION YES LED DISPLAY RS 232 / DRY CONTACT (OPTIONAL SNMP OR AS400) NORMAL / BACKUP / LOW BATTERY / FAULT / CHECK BATTERY / BUCK / BOOST ON BATTERY, LOW BATTERY, OVERLOAD, FAULT 0 - 40°C (32 - 104°F) 0 - 95% (NON-CONDENSING) < 40 dBA AT 1 METER FROM UNIT cUL, UL1778, CSA C22.2 FCC PART 15 CLASS B IEEE C62.41 CAT.A HUMIDITY SAFETY EMI / RFI SURGE / TRANSIENT UPS WxDxH mm (in.) 140x436x210 (5.5x17.2x8.3) 170x450x226 (6.7x17.7x8.9) 170x450x226 INTERNAL BATTERIES (6.7x17.7x8.9) EXTERNAL BATTERY BANK (if applicable) WEIGHT in kg (lbs) MODEL NO. UPC Order Code RACK-MOUNT MODELS 4 + Hardwired I/O SPIKE & TRANSIENT PROTECTION AUDIBLE NOISE PHYSICAL DATA 25A SINGLE LINE (2 wire RJ11) / NETWORK (UTP, RJ45) COMPATIBLE JACKS OPERATING TEMPERATURE SAFETY APPROVAL GES-302L 3kVA / 1950W 825433 22500 I/O NOISE PROTECTION AUDIBLE ALARMS ENVIRONMENT GES-152L GES-202L 1.5kVA / 975W 2kVA / 1300W 825433 22300 825433 22400 120VAC (220 optional) + / - 25% 50 or 60 Hz auto-sensing + / - 5% 120VAC +15% for 90 - 109VAC; -15% for 130 - 150VAC 8.33A 12.5A 16.6A 50Hz / 60Hz (Auto Detected) + / - 0.5% 0.5 - 1.0 TRUE SINE WAVE 3:1 (ON BATTERY) 2 - 4ms (Typical), including detection time 4 6 6 SEALED LEAD ACID - MAINTENANCE FREE 2 3 4 24VDC 36VDC 48VDC ≤ 2 to 4 Hours; Recovery = 90%, Typically ≥ 7 MIN. ≥ 7 MIN. ≥ 7 MIN. ≥ 17 MIN. ≥ 25 MIN. ≥ 25 MIN. ≥ 41 MIN. ≥ 70 MIN. ≥ 75 MIN. Available YES YES MODEM OR NETWORK COMMUNICATION INTERFACE GES-102L 1kVA / 650W 825433 22200 14.5 (32) 15 (33) 25 (55.1) 30 (66.1) GES-801LR 825433 22105 GES-102LR 825433 22201 GES-152LR 825433 22301 GES-202LR 825433 22401 483x381x133 (19x15x5.25) [3U] 28.4 (62.6) 483x381x89 (19x15x3.5) [2U] WxDxH mm (in.) WEIGHT in kg (lbs) 18 (35.3) 20 (44) 26.1 (57.5) 46 (101.4) (including battery bank) GES-302LR 825433 22501 483x381x178 (19x15x7) [4U] 46.4 (102.3) Specifications are subject to change without notice to reflect upgrades and improvement in technology. OTHER VOLTAGES AND CONFIGURATIONS ARE AVAILABLE; FOR ORDER CODES, CONSULT MANUFACTURER. EXTERNAL WRAP-AROUND BYPASS MODULES ARE AVAILABLE FOR ALL MODELS AND PERMIT UPS MAINTENANCE WITHOUT POWER INTERRUPTION TO THE LOAD. ADDITIONAL BATTERY BANKS ARE AVAILABLE FOR ALL MODELS. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 8 For 800VA to 3kVA UPS 2H This graph is designed to aid in sizing the UPS system based on load and runtime and is suitable for small loads only (i.e. 50VA to 1kVA). The horizontal axis is the percent load of a UPS system and the vertical axis is the runtime that the UPS’s internal batteries will provide. For runtimes exceeding chart scale, please contact our factory. 1H 40 MIN 30 MIN RUNTIME 20 MIN 15 MIN 10 MIN 5 MIN UPS LOAD LEVEL 10% 20% 30% 40% 50% 60% 80% 100% Example: 30 minutes of back-up time are required to power a 200VA load. Using the chart, find the back-up time required (i.e. 30 MIN) and move along the horizontal axis until you are placed between the slanted lines. At this point, follow down the vertical lines to identify the UPS Load Level % (i.e. 30%). Divide the load (i.e. 200VA) by the UPS Load Level % to identify the size of UPS required. Once calculated, round-up the calculated number to the nearest UPS rating (i.e. 200 / 0.3 = 667). The minimum VA requirement is 667VA, so you roundup to an 800VA UPS system (GES-801L). The GES-801L will supply a minimum of 30 minutes to a 200VA load. Additional Back-up Times (Battery Banks) for L Series Load Model 350W 500VA 490W 700VA 700W 1,000VA 1,050W 1,500VA 1,400W 2,000VA 2,100W 3,000VA UPC Order Code BBU-801LA BBU-801LB 825433 60000 825433 60025 42 mins 70 mins 33 mins 45 mins BBU-102LA BBU-102LB 825433 60005 825433 60030 42 mins 70 mins 33 mins 45 mins 20 mins 30 mins BBU-152LA BBU-152LB 825433 60010 825433 60035 30 mins 25 mins 90 mins 17 mins 55 mins 13 mins 40 mins BBU-202LA BBU-202LB 825433 62300 825433 60040 72 mins 42 mins 90 mins 30 mins 50 mins BBU-302LA BBU-302LB 825433 62400 825433 60045 50 mins 40 mins 90 mins 27 mins 50 mins Model Cabinet Style BBU-801LA BBU-801LB BBU-102LA BBU-102LB BBU-152LA BBU-152LB BBU-202LA BBU-202LB BBU-302LA BBU-302LB S cab S cab S cab S cab S cab B cab B cab B cab B cab B cab Dimensions (mm) 170W 170W 170W 170W 170W 260W 260W 260W 260W 260W x 450D x 225H x 450D x 225H x 450D x 225H x 450D x 225H x 450D x 225H x 540D x 740H x 540D x 740H x 540D x 740H x 540D x 740H x 540D x 740H 18 mins 40 mins Dimensions (in) Weight 6.75" x 17.7" x 9" 6.75" x 17.7" x 9" 6.75" x 17.7" x 9" 6.75" x 17.7" x 9" 6.75" x 17.7" x 9" 10.5" x 21.25" x 29" 10.5" x 21.25" x 29" 10.5" x 21.25" x 29" 10.5" x 21.25" x 29" 10.5" x 21.25" x 29" 26.5 kg (58 lbs) 33 kg (73 lbs) 26.5 kg (58 lbs) 33 kg (73 lbs) 23 kg (51 lbs) 49 kg (108 lbs) 39.5 kg (87 lbs) 61 kg (134 lbs) 37 kg (81 lbs) 61 kg (134 lbs) To meet your back-up time requirements, we offer increased back-up time by simply adding additional battery cabinets. To determine the battery bank part number, locate the UPS model number and runtime you want in the tables below. For additional runtime or for runtime calculations, please contact our factory. Specifications are subject to change without notice to reflect upgrades and improvement in technology. For more information or different runtimes, please contact CUSTOMER SERVICE toll-free at 1-877-259-2976, Ext. 451. Standard 5-year pro rated warranty with 1-year replacement. Extended warranties available. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 9 Industrial/Commercial/Critical Loads “N” & “TN11” Series Single ∅ or Multi ∅ Input Single ∅ or Multi ∅ Output Rackmount NEMA 12 Side Mount DESCRIPTION: This dual conversion UPS system converts the incoming AC supply to DC. The DC power is used to charge the batteries and supply the inverter. The inverter then inverts the DC power into AC power that, in turn, is supplied to the load. This dual conversion isolates the line from AC supply and allows for wide input power variations on both frequency and voltage. Systems in single phase output configurations range from 700VA to 20kVA. APPLICATIONS: Among other applications, the N and TN11 Series can be applied to LAN file servers, personal computers, networks and workstations, Automatic Teller Machines, telecommunications, laboratory and medical equipment, test equipment, POS equipment, robotics, PLC’s, security and emergency systems and military & government applications. ADVANCED FEATURES: Features include utility input power factor correction, self-diagnosis, an LCD display, a static bypass, smart power source monitoring and battery management, lightning, noise and surge protection, spike and transient protection, cold start/auto restart, a user selectable frequency, a generator mode and intelligent communications interface. SNMP and AS-400 adapters are available for network management. User replaceable batteries, emergency power off control, an isolation transformer and maintenance bypass switches are standard on the TN11 and TN31 Series. COMPLETE PROTECTION: The N and TN11 Series UPS’s are designed with comprehensive Spike, Transient and Surge protection, which prevents destructive hardware damage and extends system life. The high end EMI/RFI filtering design prevents electrical Common and Normal Mode noise from affecting computer operation, data or files, including when the UPS is in Bypass Mode. OPERATING VOLTAGES AND FREQUENCIES: The N and TN11 Series UPS’s are designed to function at wide voltage and frequency variations. This wide input range makes the systems ideal for generator and problematic area applications. Also available is a frequency converter option allowing the user to select the output frequency at 50 or 60Hz. SELF-DIAGNOSIS AND INFORMATION INDICATORS: Each N and TN11 Series UPS is equipped with a microprocessor that performs a self-diagnosis once a month to ensure continuous runtime. The microprocessor is able to identify failures, display the failure on the LCD display and send audio and visual alarms (off site monitoring). COLD START: This feature allows the N and TN11 Series UPS’s to be powered up when the utility is not present. AUTO RESTART: This user selectable feature allows the UPS to restart automatically when utility becomes available, provided it has been shutdown due to an extended blackout. SMART POWER SOURCE MONITORING AND BATTERY MANAGEMENT: Via microprocessor-based electronics, the N and TN11 Series UPS’s produce a strict true sine wave output regardless of the input. It also controls the on-battery and low battery shutdown, which prevents full discharge, thereby extending the battery performance and battery life. INTELLIGENT COMMUNICATION INTERFACE: Each N and TN11 Series UPS is equipped with a RS232 and dry contact interface port, for which we provide various powerful management software programs. For the more complex network environment, we support Simple Network Management Protocol (SNMP), AS400 and others. REMOTE SHUTDOWN AND EMERGENCY STOP: Features include remote shutdown via communication port, emergency stop via contacts. An optional push button control is available. OPTIONAL EXTENDED RUNTIMES: To meet your back-up time requirements, we offer increased back-up time by simply adding additional hot pluggable battery cabinet(s). OPTIONAL USB: Available at time of order. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 10 “N” Series TRUE SINE WAVE ON LINE UPS N-SERIES GENERAL INPUT OUTPUT Single ∅ Input & Output MODEL NO. Maximum Capacity UPC Order Code Nominal Voltage Voltage Range Bypass Voltage Phase Frequency Window Synchronization Window Power Factor Output Voltage Voltage Regulation Frequency Regulation Voltage Distortion - THD Max Current @ 120VAC Transient Response Overload Capacity Crest Factor Efficiency Transfer Time GES-701N 700VA/490W 825433 30100 5.8A Outlets BATTERY PROTECTION INTERFACE ENVIRONMENT CONFORMANCE PHYSICAL DATA RACK-MOUNT MODELS Battery Type Quantity Voltage Recharge Time Advanced Battery Management Backup Time - Full Load Extended Runtime Output Short Abnormal Voltage Abnormal Frequency I/O Noise Protection I/O Spike and Transient Telephone/Network Display Audible Alarms Communications Emergency Power OFF Operating Temperature Humidity Audible Noise Safety Approval Surge / Transient EMI/RFI Warranty W x D x H mm (in.) Weight in kg (lbs.) MODEL NO. UPC Order Code WxDxH mm (in.) Weight in kg (lbs.) MODEL NO. UPC Order Code MARINE GRADE MODELS WxDxH mm (in.) Weight in kg (lbs.) Approval 2 24VDC GES-102N GES-152N 700VA - 3kVA GES-202N GES-302N 1000VA/700W 1500VA/1050W 2000VA/1400W 3000VA/2100W 825433 30200 825433 30300 825433 30400 825433 30500 120VAC (OPTIONAL 220VAC AVAILABLE) 60VAC/40% Load, 70VAC/70% Load, 80VAC - 144VAC/100% Load +/-10%, +10/-15%, +15/-20% (User Selectable) Single Phase (L-N-G) 45-65Hz (+/-2%, +/-5%, +/-7% - User Selectable) +/- 3Hz 0.97 100/110/115/120/127VAC (User Selectable) +/- 2% +/- 0.25Hz (Battery or Free Run Mode) <3% Linear Load, <5% Non-linear Load 8.2A 12.4A 16.5A 24.7A 4% (100% Load Change) 125% for 1 min. / 150% for 10 sec. 3:1 86% normally, > 98% (High efficiency mode) Zero 10-(5-20R-US), 10-(5-15R), 6-(5-15R) 1-(L5-20R) 1-(L5-30R) Sealed Lead Acid, Maintenance Free - Hot Swappable Cartridge 3 3 6 6 36VDC 36VDC 72VDC 72VDC <4 Hrs to 90% Recovery Auto Self-test, Temperature Compensated 3-Stage Charging, Load Dependent Discharge 9 min 10 min 8 min 12 min 8 min Available YES YES YES Common & Normal Noise Suppression YES RJ11/RJ45 LCD / LED - Status, Readings and Setup Parameters On Battery, Low Battery, Overload, Fault RS232 / Dry Contact / (Optional: USB, SNMP, AS400) YES - Via Normally Closed Contact 0 - 40 °C (32 - 104 °F) 0 - 95% (Non-condensing) <40 dBA at 1 Meter UL1778, CSA C22.2 UL, cUL, (Optional ABS [American Bureau of Shipping] see below) IEEE C62.41 CAT.A FCC Part 15 Two Year Factory Warranty (Optional Extendable Warranties Available) 155x410x238 (6.0"x16.5"x9.4") 225x425x360 (8.9"x16.7"x14.2") 13.5 (29.7) 16.2 (35.6) 17.0 (37.4) 31.6 (68.4) 32.5 (71.5) GES-701NR GES-102NR GES-152NR GES-202NR GES-302NR 825433 30111 825433 30202 825433 30301 825433 30403 825433 30501 428x425x84 (16.9"x16.7"x 3.3") [2U] 428x635x84 (16.9"x25.0"x3.3") [2U] 18 (35.3) 20 (44.1) 25 (55) 31.6 (68.4) 32.5 (71.5) GES-701N-ABS GES-102N-ABS GES-152N-ABS GES-202N-ABS GES-302N-ABS 825433 30112 825433 30231 825433 30232 825433 30233 825433 30234 155x410x238 260x555x700 (10.2x21.9x27.6) (6.0"x16.5"x9.4") 30.5 (67.2) 20 (44.1) 42 (92.2) 47 (103.5) ABS(American Bureau of Shipping), UL, cUL Specifications are subject to change without notice to reflect upgrades and improvement in technology. INDUSTRIAL CONTAINERS ARE AVAILABLE (NEMA 12, NEMA 4, ETC.); CONSULT MANUFACTURER. EXTERNAL WRAP-AROUND BYPASS MODULES ARE AVAILABLE FOR ALL MODELS, PERMITTING UPS MAINTENANCE WITHOUT POWER INTERRUPTION TO THE LOAD. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 11 For 300VA to 3kVA UPS 2H This graph is designed to aid in sizing the UPS system based on load and runtime and is suitable for small loads only (i.e. 50VA to 1kVA). The horizontal axis is the percent load of a UPS system and the vertical axis is the runtime. For runtimes exceeding chart scale, please contact our factory. 1H 40 MIN 30 MIN RUNTIME 20 MIN 15 MIN 10 MIN 5 MIN UPS LOAD LEVEL 10% 20% 30% 40% 50% 60% 80% 100% Example: 30 minutes of back-up time are required to power a 200VA load. Using the chart, find the back-up time required (i.e. 30 MIN) and move along the horizontal axis until you are placed between the slanted lines. At this point, follow down the vertical lines to identify the UPS Load Level % (i.e. 30%). Divide the load (i.e. 200VA) by the UPS Load Level % to identify the size of UPS required. Once calculated, round-up the calculated number to the nearest UPS rating (i.e. 200 / 0.3 = 667). The minimum VA requirement is 667VA, so you round-up to a 700VA UPS system (GES-701N). The GES-701N will supply a minimum of 30 minutes to a 200VA load. Additional Back-up Times (Battery Banks) for N Series Load 350W 500VA 490W 700VA 700W 1,000VA 1,050W 1,500VA 1,400W 2,000VA Model UPC Order Code BBU-701NA BBU-701NB 825433 60300 825433 60325 28 mins 48 mins 17 mins 33 mins BBU-102NA BBU-102NB 825433 62600 825433 62610 30 mins 25 mins 50 mins 17 mins 33 mins BBU-152NA BBU-152NB BBU-152NC 825433 62700 825433 62710 825433 62730 30 mins 25 mins 50 mins 100 mins 17 mins 33 mins 60 mins 13 mins 25 mins 40 mins BBU-202NA BBU-202NB BBU-202NC 825433 62800 825433 62810 825433 60365 30 mins 150 mins 25 mins 100 mins 18 mins 60 mins 100 mins BBU-302NA BBU-302NB BBU-302NC 825433 62900 825433 62910 825433 62920 30 mins 150 mins 25 mins 100 mins 18 mins 60 mins 100 mins Model BBU-701NA BBU-701NB BBU-102NA BBU-102NB BBU-152NA BBU-152NB BBU-152NC BBU-202NA BBU-202NB BBU-202NC BBU-302NA BBU-302NB BBU-302NC Cabinet Style S cab S cab S cab S cab S cab S cab B cab S cab B cab B cab S cab B cab B cab Dimensions (mm) 170W 170W 170W 170W 170W 170W 260W 170W 260W 260W 170W 260W 260W x 450D x 225H x 450D x 225H x 450D x 225H x 450D x 225H x 450D x 225H x 450D x 225H x 540D x 740H x 450D x 225H x 540D x 740H x 540D x 740H x 450D x 225H x 540D x 740H x 540D x 740H Dimensions (in) Weight 6.75" x 17.7" x 9" 6.75" x 17.7" x 9" 6.75" x 17.7" x 9" 6.75" x 17.7" x 9" 6.75" x 17.7" x 9" 6.75" x 17.7" x 9" 10.5" x 21.25" x 29" 6.75" x 17.7" x 9" 10.5" x 21.25" x 29" 10.5" x 21.25" x 29" 6.75" x 17.7" x 9" 10.5" x 21.25" x 29" 10.5" x 21.25" x 29" 20 kg (44 lbs) 26.5 kg (58 lbs) 23 kg (51 lbs) 33 kg (73 lbs) 23 kg (51 lbs) 33 kg (73 lbs) 49 kg (108 lbs) 33 kg (73 lbs) 84 kg (185 lbs) 120 kg (264 lbs) 33 kg (73 lbs) 84 kg (185 lbs) 120 kg (264 lbs) 2,100W 3,000VA 14 mins 40 mins 60 mins To meet your back-up time requirements, we offer increased back-up time by simply adding additional battery cabinets. To determine the battery bank part number, locate the UPS model number and runtime you want in the tables below. For additional runtime or for runtime calculations, please contact our factory. Specifications are subject to change without notice to reflect upgrades and improvement in technology. For more information or different runtimes, please contact CUSTOMER SERVICE toll-free at 1-877-259-2976, Ext. 451. Standard 5-year pro rated warranty with 1-year replacement. Extended warranties available. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 12 “TN11” Series Single ∅ Input (2 wire) & Single ∅ Output (2 or 3 wire) TRUE SINE WAVE ON-LINE UPS GENERAL 6kVA - 20kVA Model No. GES-602TN11 Maximum Capacity UPC Order Code TN11 SERIES GES-103TN11 GES-153TN11 GES-203TN11 6kVA / 4.2kW 10kVA / 7kW 15kVA / 10.5kW 20kVA / 14kW 825433 40030 825433 40200 825433 40400 825433 40500 208 or 240VAC Rated Voltage (Nominal) 170 - 276VAC Voltage Range INPUT 1 Ø (2 WIRE + GND) Phase 45 - 65 Hz Frequency Range ≤ 0.98 Power Factor 120, 120/240, 110/220VAC (other configurations available) Voltage ± 2% Voltage Regulation 1 Ø (3 wire + GND) [other configurations available] Phase Total Current @ 240VAC 25A 41.7A 62.5A < 3% Linear Load; < 5% Rectified Load THD 0.7 Load Power Factor OUTPUT 1Hz / second Slew Rate ± 4% (100% Load Change) Transient Response 105% - 150% for 20 seconds Overload Capacity 3:1 Crest Factor > 85% Efficiency (AC-AC) Heat Dissipation 2494 4153 6227 Hard-Wired (other configurations available) Outlets Sealed lead acid - maintenance free Battery Type Voltage 240VDC 240VDC 240VDC Full Load > 10 Min. > 4 Min. > 8 Min. > 4 Min. Half Load > 25 Min. > 13 Min. > 19 Min. > 13 Min. Available - Consult "Battery Banks" EXTENDED RUN TIME YES Output Short YES Abnormal Voltage PROTECTION I/O Noise Protection Common & Normal Mode Noise Suppression I/O Spike & Transient Protection YES RS-232 / Dry Contact / (Optional SNMP or AS400) Communication INTERFACE LEDs and LCD Status Display Display On Battery, Low Battery, Overload, Fault Audible Alarms 0 - 40°C (32 - 104°F) Operating Temperature ENVIRONMENT 0% - 90% (Non-Condensing) Humidity ≥ 55 dBA at 1 meter from unit Audible Noise Safety/Approvals SAFETY APPROVAL UL1778, CSA C22.2, ABS(American Bureau of Shipping), UL, cUL FCC Class A EMI / RFI IEEE C62.41 CAT.A Surge / Transient PHYSICAL DATA 240VDC 5 - 8 Hours; recovery = 90%, typically Recharge Time BACKUP POWER TIME 8303 0ms Transfer Time BATTERY 83.3A 50Hz / 60Hz ± 0.5% (Auto-Sensing) Frequency Accuracy WxDxH mm (in) Weight in kg (lbs) 260x555x700 (10.2x21.9x27.6) 340x640x980 (13.4x25.2x38.6) 114 (251) 250 (551) 340x760x1160 (13.4x29.9x45.7) 255 (562) 265 (584) Specifications are subject to change without notice to reflect upgrades and improvement in technology. OTHER VOLTAGES AND CONFIGURATIONS ARE AVAILABLE; FOR ORDER CODES, CONSULT MANUFACTURER. AN EXTERNAL WRAP-AROUND BYPASS MODULE IS AVAILABLE FOR ALL MODELS, PERMITTING UPS MAINTENANCE WITHOUT POWER INTERRUPTION TO THE LOAD. INDUSTRIAL CONTAINERS ARE AVAILABLE (NEMA 12, NEMA 4, ETC.); CONSULT MANUFACTURER. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 13 Additional Back-up Times (Battery Banks) To meet your back-up time requirements, we offer increased back-up time by simply adding additional battery cabinets. To determine the battery bank part number, locate the UPS model number and runtime you want in the tables below. For additional runtime or runtime calculations, please contact our factory. Load UPC 60592 60600 60940 60941 60942 60943 60944 Cabinet D E KA KB KC KD KE UPC 60592 60600 60940 60941 60942 60943 60944 Cabinet PD PE KA KB KC KD KE 6000VA 4200W 8000VA 5600W 10000VA 7000W 12000VA 8400W 15000VA 10500W 20000VA 14000W 20 mins 50 mins 60 mins 120 mins 170 mins 280 mins 410 mins 16 mins 40 mins 35 mins 90 mins 120 mins 200 mins 310 mins 15 mins 30 mins 30 mins 65 mins 90 mins 150 mins 260 mins 11 mins 18 mins 20 mins 45 mins 70 mins 130 mins 180 mins 12 mins 15 mins 33 mins 50 mins 90 mins 130 mins 7 mins 10 mins 20 mins 35 mins 60 mins 100 mins Dimensions mm(inch) Weight 235(9.25) W x 546(21.5) D x 552(21.75) H 400(15.7) W x 650(25.5) D x 1,020(40) H 815(32) W x 865(34) D x 1,930(76) H 815(32) W x 865(34) D x 1,930(76) H 815(32) W x 865(34) D x 1,930(76) H 815(32) W x 865(34) D x 1,930(76) H 815(32) W x 865(34) D x 1,930(76) H 80kg (177lbs) 353kg (777lbs) 629kg (1,387lbs) 758kg (1,671lbs) 885kg (1,951lbs) 1,022kg (2,253lbs) 1,277kg (2,815lbs) For more information or different runtimes, please contact CUSTOMER SERVICE toll-free at 1-877-259-2976, Ext. 451. Batteries feature a standard 5-year pro rated warranty with 1-year replacement. Extended warranties available. Specifications are subject to change without notice to reflect upgrades and improvement in technology. FOR ALWAYS ON™ UPC ORDER CODES, VISIT WWW.ALWAYSON.COM. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 14 Industrial/Commercial “NX” Series Three ∅ In / Single or Three ∅ Out NX31 and NX33 TRUE SINE WAVE ON-LINE UPS Due to the increasing requirements placed by today’s users and technological advances in present day electronics, the demand for an industrial UPS system with commercial capabilities is required. Always On™ designed NX Series UPS systems to provide clean, isolated, reliable and consistent power to all critical loads. The NX Series UPS’s are dual conversion, on-line, three phase, intelligent systems for centralized power protection and distribution. The “dual conversion” means AC utility is converted into DC power which, in turn, charges the batteries and supplies the inverter, which inverts the DC power back into highly regulated and isolated AC power. These continuous three phase on-line UPS’s are available in models from 10kVA up to 250kVA. For high power redundant applications, the NX Series UPS’s can be installed with up to eight units in parallel, achieving N+1 redundancy. Isolated Parallel Redundant Operation (IPRO) is an optional feature of the NX Series, whereby the systems are controlled in a true peer-to-peer configuration with redundancy in all critical elements and functions. This advanced technology provides the greater system reliability and expansibility required for mission critical applications. The NX Series UPS’s are also energy efficient. The models up to 40kVA are equipped with GES (Green Energy System) to maximize savings on operating costs without compromising security. GES for IPRO configuration is a special firmware package which allows significant reductions in energy consumption and operating cost during low load conditions. Controls within the CPU monitor and distribute the load to maintain the maximum efficiency and reduce energy consumption. The GES mode for IPRO is programmed to take care of load changes during the day or the degree of redundancy required. The NX Series UPS’s provide reliable and robust protection for mission critical installations from IT to telecommunications and infrastructure applications such as airports, hospitals and financial companies. Features and Benefits Full Galvanic Isolation: Full Galvanic Isolation provides a completely isolated and referenced output. This isolation protection provides a proven solution to problems created by induced voltages affecting the critical loads. Since the output circuit to the load is completely isolated and no noise induced on the neutral can permeate to the loads, systems operate in a more reliable fashion. Also, this type of protection increases the life span of equipment by eliminating noise, which breaks down components. Modular Design: Each major component (inverter, rectifier and static switch) on the NX Series are installed on slide-out modules. This allows for quick repair (mean time to repair of >30 minutes) and easy field upgradeability. High efficiency: Thanks to IGBT technology, the NX Series UPS’s provide high efficiency (up to 94.5%). This, combined with IPRO, results in the most cost-efficient and reliable UPS solution in the industry. Fully digital: DSP (Digital Signal Processor), flash memory and SVM strategy are the technology corner stones of the new age of power quality and reliability. Extremely flexible: The NX Series UPS offers tailor-made power protection to comply with your individual installation requirements. Options include passive filter, a 6-pulse rectifier (instead of the standard 12-pulse rectifier) for units under 80kVA and a Smart Panel (SP). In addition, a comprehensive software suite can be added for mission control and data protection. FOR ALWAYS ON™ UPC ORDER CODES, VISIT WWW.ALWAYSON.COM. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 15 “NX” Series Three ∅ In / Single or Three ∅ Out NX31 and NX33 TRUE SINE WAVE ON-LINE UPS 10kVA - 250kVA GENERAL DATA Topology True On-Line, Dual Conversion Nominal output at PF=0.8 kVA 10 15 20 30 40 50 60 80 100 120 160 100% load, 0.8 PF % 90 90 90 90 90 90 90 90 90 90 90 90 50% load, 0.8PF True galvanic isolation from input to output % 88 88 88 88 88 88 88 88 88 88 88 88 3,000 (0.89) 4,500 (1.3) 6,100 (1.8) 18,200 (5.3) 24,300 (7.1) 30,300 (8.9) Overall efficiency Heat rejection at 100% load, 0.9PF and charged battery Yes BTU/hr (kW) Audible noise level (at 1 m) dB (A) UPS Operating temperature range 9,100 12,100 (2.7) (3.6) < 65 at 1m o o -15oC to +50oC (5oF to 122oF) Battery 0oC to 40oC (32oF to 104oF) (VRLA) Storage time is 6 months at 25oC (77oF) Higher temperatures reduce battery storage time 0% to 90%, non-condensing Without Derating <1,500m (5,000ft.) No derating Type Indoor (NEMA 1) [Drip shield available] Safety Internal dead front construction Cooling Forced air Colour Manufacturer colour (ivory) Suitable for handling by forklift or overhead crane Rigging Installation Mounting Casters and leveling feet [Optional seismic rated mounting available] Installation and maintenance access Front access required for normal maintenance Conduit access Bottom entry standard [Optional top entry] Standards UL 1778, CSA 22.2, IEC 62040, FCC Class A, EN50091-1, -2 [Optional ABS or UL-924 available] 4kV contact / 8kV air discharge Electrostatic discharge immunity Stand-alone Standard Configuration RECTIFIER Configuration 12 pulse and harmonic filter Voltage (Multitap configurable) 208/480/600, L-L VAC, 3 phase, 4 (or 3) wire + ground (-20% to +15% without battery discharge) 50 / 60 Hz +/- 7% Frequency Power Factor 0.8 at full load Inrush current Limited by soft-start circuit Power walk-in: 20 seconds Input Output Voltage tolerance Output +/- 1% DC ripple voltage +/- 0.5% DC ripple current Nominal input current (A) Maximum Output DC Current @ 392VDC Max. 5% of battery capacity expressed in amps 208/120 30 46 61 92 123 154 185 247 * * * * 480/277 13 20 26 39 52 65 78 104 130 157 209 326 600/347 10 16 21 31 42 52 62 83 104 125 167 260 27 40 54 81 108 217 271 325 434 678 Current THD Specifications are subject to change without notice to reflect upgrades and improvement in technology. 135 162 12 Pulse Rectifier: 9% FOR ALWAYS ON™ UPC ORDER CODES, VISIT WWW.ALWAYSON.COM. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 16 75,800 (22.2) (20 C to 25 C (68 F to 77 F) Higher temperatures reduce battery life expectancy Relative Humidity Enclosure 36,400 48,500 (10.7) (14.2) < 70 at 1m o UPS Maximum Altitude 15,200 (4.4) 0oC to 40oC (32oF to 104oF) o Battery Storage temperature range 250 “NX” Series Three ∅ In / Single or Three ∅ Out TRUE SINE WAVE ON-LINE UPS BATTERY Nominal output at PF=0.8) Battery compatibility Number of cells Voltage range 10kVA - 250kVA kVA Float voltage at 20oC (68oF) Low voltage level Minimum discharge voltage Boost charge voltage Maximum Charge Current (ADC) Recharge time for 30 minute battery to 95% capacity Battery ground fault detection Automatic and manual battery test INVERTER Nominal output at PF=0.8) kVA DC voltage input range Nominal output voltage (Multitap configurable) Maximum output wattage (kW) 208/120VAC Nominal Output Current (A) (Linear 480/277VAC Load) 600/347VAC Inverter bridge Output isolation transformer Output power factor Frequency lock range Output waveform Static Load step 0% - 100% - 0% Output voltage tolerance Load step 0% - 50% - 0% 100% unbalanced load (L-N) 100% linear load Output voltage distortion 100% non-linear load Crest factor capability 100% balanced load Phase displacement 100% unbalanced load Free running Output frequency < 110% 110 - 125% Overload capability (on inverter) 125 - 150% > 150% Efficiency (100% Load) 10 15 20 30 5 8 10 16 10 15 20 30 8 22 10 8 12 33 14 12 16 44 19 15 100 120 160 250 21 27 32 43 54 10 times the discharge time (15 times for 40kVA) Standard Standard 65 86 135 50 60 80 100 120 285 - 415VDC 208/120 or 480/277 or 600/347, L-L VAC, 3 phase, 4 wire + ground 160 250 24 66 29 23 40 50 60 80 Sealed lead-acid [Optional NiCD or flooded] 174 Cells 295 - 410VDC 396VDC 320VDC 295VDC 410VDC 40 32 40 48 64 88 111 133 177 39 48 58 77 31 38 46 61 IGBT technology and Pulse Width Modulated Standard 0.8 45 - 55Hz / 55 - 65Hz True Sine Wave +/- 1% +/- 3%, recovering to within +/- 1% in 1 cycle +/- 2%, recovering to within +/- 1% in 1 cycle +/- 3% < 2% THD maximum < 3% THD maximum Greater than 3:1 80 * 96 77 96 * 116 92 128 * 154 123 200 * 241 192 94% 94% 94% 94% 120o +/- 1% 120o +/- 2.5% 50 / 60Hz, +/-0.1% Synchronized with utility Continuous 15 minutes 5 minutes 30 seconds 94% 94% 94% 94% 94% 94% 94% 94% BY-PASS Input configuration Primary components Voltage range Frequency range Efficiency Common to rectifier [Optional dual input] Full load rated static switch, Back-feed protection and Internal maintenance by-pass +/- 20% of input voltage (line to neutral) 45 - 55Hz / 55 - 65Hz 99.50% Inverter to bypass 0 ms Transfers time Bypass to inverter 0 ms 200% of UPS rating 30 seconds Overload capability 400% of UPS rating 1 second Short circuit capability (on by-pass) 1000% for 1/2 cycle (non-repetitive) Yes Isolation transformer Specifications are subject to change without notice to reflect upgrades and improvement in technology. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 17 “NX” Series Three ∅ In / Single or Three ∅ Out TRUE SINE WAVE ON-LINE UPS 10kVA - 250kVA EXTERNAL INTERFACE Alarm contacts Ethernet communications Serial communication Input signals 8 pre-defined contacts (COM, BATL, BACKUP, BYPASS, SS, FAULT, OVL, INVON) SNMP adapter RS-232 & RS-485 Emergency Power Off contacts provided (optional switch available) FRONT PANEL CONTROLS, SIGNALS & ALARMS Active mimic Diagram LED display Audile alarm LCD Display Push-Buttons Represents the operational status of the UPS, with integrated LED's and power flow indicators. Displays operational and fault conditions Audible signal active when any alarm condition is present. Display of UPS metering functions and event history Inverter On, Inverter Off, Inverter Control, Up key, Down key, Enter key OPTIONAL FEATURES Marine approval Emergency Lighting Mounting options Dual Input Warranty Redundant operation Remote status Panel Battery Cabinets ABS (American Bureau of Shipping) Certified UL-924, BMEC and CCMC Seimic rated mounting, as well as certified is available. Bypass and rectifer have separate inputs Extended warranty and service packages available N+1, A+B Buss system and IPRO (Isolated Parallel Redundant Operation) Active mimic diagram w/ Stop Operation and Summary Alarms. Additional matching battery cabinets to extend runtime MECHANICAL DATA NX-Series UPS UPS Rating (kVA) W (Width) Dimensions D (Depth) H (Height) UPS Weight Floor Loading 10 15 20 30 40 50 60 80 100 120 160 250 550mm (21.7") 550mm (21.7") 550mm (21.7") 550mm (21.7") 550mm (21.7") 550mm (21.7") 550mm (21.7") 1,100mm (44.0") 1,100mm (44.0") 1,100mm (44.0") 1,100mm (44.0") 2,200mm (86.6") 800mm (32.0") 800mm (32.0") 800mm (32.0") 800mm (32.0") 800mm (32.0") 800mm (32.0") 800mm (32.0") 800mm (32.0") 800mm (32.0") 800mm (32.0") 800mm (32.0") 800mm (32.0") 1,600mm (64.0") 1,600mm (64.0") 1,600mm (64.0") 1,600mm (64.0") 1,600mm (64.0") 1,600mm (64.0") 1,600mm (64.0") 1,600mm (64.0") 1,600mm (64.0") 1,600mm (64.0") 1,600mm (64.0") 1,600mm (64.0") 380kg (838lbs) 415kg (915lbs) 450kg (992lbs) 580kg (1,279lbs) 650kg (1,433lbs) 710kg (1,565lbs) 850kg (1,874lbs) 920kg (2,024lbs) 1,050kg (2,310lbs) 1,300kg (2,860lbs) 1,600kg (3,520lbs) 2,700kg (5,953lbs) 864 kg/sq.m (177 lbs/sq.ft.) 943 kg/sq.m (193 lbs/sq.ft) 1,023 kg/sq.m (210 lbs/sq.ft) 1,318 kg/sq.m (270 lbs/sq.ft.) 1,477 kg/sq.m (303 lbs/sq.ft.) 1,614 kg/sq.m (330 lbs/sq.ft) 1,932 kg/sq.m (396 lbs/sq.ft.) 1,672 kg/sq.m (207 lbs.sq.ft.) 1,909 kg/sq.m (236 lbs/sq.ft.) 2,363 kg/sq.m (293 lbs/sq.ft.) 2,909 kg/sq.m (360 lbs/sq.ft.) 1,534 kg/sq.m (314 lbs/sq.ft.) Specifications are subject to change without notice to reflect upgrades and improvement in technology. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 18 “NX” Series Three ∅ In / Single or Three ∅ Out TRUE SINE WAVE ON-LINE UPS 10kVA - 250kVA Back-up Times (Battery Banks) Full load runtime calculations for NX Series UPS systems from 8kW (10kVA) to 160kW (200kVA). Load 4000W 5000VA 8,000W 10,000VA 12,000W 15,000VA 25 mins 90 mins 9 mins 40 mins 36 mins 80 mins 108 mins 4 mins 20 mins 23 mins 36 mins 76 mins 105 mins 40,000W 50,000VA 48,000W 60,000VA 64,000W 80,000VA 6 mins 12 mins 21 mins 33 mins 66 mins 92 mins 10 mins 18 mins 23 mins 40 mins 72 mins 12 mins 18 mins 24 mins 38 mins 16,000W 20,000VA 24,000W 30,000VA 32,000W 40,000VA 15 mins 18 mins 32 mins 46 mins 81 mins 108 mins 7 mins 10 mins 17 mins 28 mins 40 mins 72 mins 5 mins 10 mins 19 mins 24 mins 38 mins Model BBU-NX33D BBU-NX33E BBU-NX33KF BBU-NX33KG BBU-NX33KH BBU-NX33KI BBU-NX33KJ Load 80,000W 96,000W 128,000W 160,000W 100,000VA 120,000VA 160,000VA 200,000VA Model BBU-NX33KG BBU-NX33KH BBU-NX33KI BBU-NX33KJ 2 X BBU-NX33KI 2 X BBU-NX33KJ Model Cabinet Style 8 mins 13 mins 21 mins 33 mins 5 mins 10 mins 18 mins 23 mins Dimensions 12 mins 18 mins 8 mins 13 mins Weight BBU-NX33D D Cabinet 235 (9.25") W x 546 (21.5") D x 552 (21.75") H 117 kg (258 lbs) BBU-NX33E E Cabinet 511 kg (1,126 lbs) 400 (15.75") W x 682 (26.75") D x 1,008 (39.75") H BBU-NX33KF KF Cabinet 1,314 (51.5") W x 850 (33.5") D x 1,945 (76.5") H 814 kg (1,791 lbs) BBU-NX33KG KG Cabinet 1,314 (51.5") W x 850 (33.5") D x 1,945 (76.5") H 1,024 kg (2,258 lbs) BBU-NX33KH KH Cabinet 1,314 (51.5") W x 850 (33.5") D x 1,945 (76.5") H 1,204 kg (2,649 lbs) BBU-NX33KI KI Cabinet 1,314 (51.5") W x 850 (33.5") D x 1,945 (76.5") H 1,398 kg (3,076 lbs) BBU-NX33KJ KJ Cabinet 1,314 (51.5") W x 850 (33.5") D x 1,945 (76.5") H 1,764 kg (3,881 lbs) Specifications are subject to change without notice to reflect upgrades and improvement in technology. For 250kVA and 320kVA UPS systems, contact factory for models. NX-Series UPS Block Diagram Rectifier 1 Inverter 2 Static Bypass 3 Maintenance Bypass 4 Output Isolation Transformer 5 Output to Load 6 Battery Bank 7 Battery Contactor 8 9 AC Utility FB Battery Fuses or Circuit Breaker F1 AC Input Fuses or Circuit Breaker F2 Optional AC Input Fuses or Circuit Breaker for Alternate Input Lb Battery Line L In Input Line L In Alt Optional Alternate Input 9 Optional Dual Input FOR ALWAYS ON™ UPC ORDER CODES, VISIT WWW.ALWAYSON.COM. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 19 “NX” Series Three ∅ In / Single or Three ∅ Out TRUE SINE WAVE ON-LINE UPS NX31 and NX33 10kVA - 250kVA System Configurations The standard configurations presented are intended only to illustrate the minimum number of enclosures required for each system and our recommended installation arrangement. These enclosures are shipped as separate components. Allow Min 60cm (2’) Allow Min 60cm (2’) Allow Min 1m (3’) 250 to 320kVA UPS system 60 to 160kVA system 10 to 50kVA UPS system Allow Min 1m (3’) Allow Min 60cm (2’) Allow Min 1m (3’) Dimensions: 2,200 mm (86.5”) W 812 mm (32”) D 1,600 mm (63”) H Dimensions: 1,100 mm (43.25”) W 812 mm (32”) D 1,600 mm (63”) H Dimensions: 550 mm (21.75”) W 812 mm (32”) D 1,600 mm (63”) H Battery Cabinet Configurations Allow Min 60cm (2’) D Cabinet Dimensions: 235 mm (9.25”) W 546 mm (21.5”) D 552 mm (21.75”) H Allow Min 1m (3’) Allow Min 60cm (2’) Allow Min 1m (3’) Allow Min 60cm (2’) E Cabinet Dimensions: 400 mm (15.75”) W 682 mm (26.75”) D 1,008 mm (39.75”) H Allow Min 1m (3’) K Series Cabinet Dimensions: 1,314 mm (51.5”) W 850 mm (33.5”) D 1,945 mm (76.5”) H FOR ALWAYS ON™ UPC ORDER CODES, VISIT WWW.ALWAYSON.COM. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 20 “NX” Series Three ∅ In / Single or Three ∅ Out TRUE SINE WAVE ON-LINE UPS NX31 and NX33 10kVA - 250kVA Features Extension of battery life Batteries are a critical part of every UPS solution, acting as the power supply in the event of an AC power failure. Batteries are sensitive products that need to be handled and monitored continuously and carefully in order to increase their lifetime and predictability. Always On™ includes superior battery management within the entire NX Series family and is a comprehensive management and monitoring system that prevents batteries from overcharging and deep discharging. Load dependent runtime indication and re-calibration procedures are standard features to optimize life cycle cost and system reliability. Features and Benefits: The NX Series features a ”no surprises” automatic battery test, a deep calibration test, which provides battery performance tracking, boost charging, which enables fast recharging of batteries and a temperature compensated battery charger, which prevents overcharging. The load dependent end of the discharge voltage gives deep discharge protection and the “no-load” shutdown maintains your battery’s operational life under no-load conditions. UPS Monitoring and Management via SNMP Data Protection & Monitoring: The primary function of Always On™’s protection software is the safeguarding of data and the Operating Systems. Using our software reduces the risk of system crashes and/or data loss. Always On™’s software provides event handling and computer shutdown for all major operating systems to enhance security of critical data. Multi-vendor and multi-platform environments, as well as client-server structures, are managed. Direct access of remote UPS and active management of single modules in multi-unit configurations are the keys to efficient and predictable power quality management. The SNMP Client/Agent structure, direct link, or remote connection enables a network manager or facility engineer to permanently monitor and control local or remote Always On™’s UPS systems and the equipment and processes they protect. Snap-in modules allow easy integration into the leading Network Management Systems. A real-time graphical display of critical UPS parameters and environment information of multiple decentralized UPS’s, as well as statistical data and event log files, are available on every local computer display and network management system or on the Internet. Additionally, UPS status information changes can be sent to such varied information carriers as SMS, network management systems, e-mail or fax. Options Isolated Parallel Redundant Operation (IPRO) Highest standard for reliability: Power reliability is business reliability. Mission critical applications require the highest availability of power. Always On™’s unique IPRO technology sets the highest standard for power reliability, and IPRO compatible NX Series UPS’s are field upgradable. Additional units can be added to increase the total power output of a system or to create a redundant system with no single point of failure. Decentralized bypass, redundant control electronics and redundant batteries offer perfect load-sharing and fault-tolerant operations. Protection: Short circuit, over-temperature and over-voltage protection is built in to protect the NX Series UPS against any form of misuse. Back-feed protection, complete protection circuits and excellent overload behaviour provide outstanding user protection and application security, all in conjunction with full galvanic isolation on the output of every UPS system used in the parallel operation. Features and Benefits: Up to eight NX Series units can be connected in a redundant-parallel system (N+1 redundant). It also features a decentralized bypass, redundant control electronics, active-active system management and fault tolerant operation, as well as a transparent fail over procedure in case of UPS failure or for maintenance and no single point of failure. Drip Shield The addition of a drip shield ensures that liquids and other debris do not enter your NX Series UPS through the top cooling vents. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 21 “NX” Series Three ∅ In / Single or Three ∅ Out TRUE SINE WAVE ON-LINE UPS 10kVA - 250kVA Module Interior Layout Rectifier Module Inverter Module IPRO TRUE REDUNDANT SYSTEM Each system component is redundant; Rectifier, Batteries, Inverter, Static Switch, Control System. Failure of one system component still allows redundancy on remaining components. 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) Complete maintenance and repair of one UPS while the other UPS remains on-line with total battery capacity available. 11) 12) 13) 14) 15) 16) 17) 18) SOURCE 1 SOURCE 2 AUTO TRANSFER SWITCH 3PH 3W+G UPS1 INPUT UPS2 INPUT INPUT BREAKER BYPASS BREAKER RESERVE BREAKER RECTIFIER BREAKER RECTIFIER INVERTER STATIC SWITCH BATTERIES BBU1 BBU2 UPS OUTPUT 3PH 3W+G Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 22 “NX” Series Three ∅ In / Single or Three ∅ Out External Bypass Systems TRUE SINE WAVE ON-LINE UPS 10kVA - 250kVA A separate cabinet to allow for complete removal of the UPS system from the load, while still supplying the load with conditioned power. Always On™ offers various systems which include isolation transformers for different voltage configurations, distribution panels, electro-mechanical interlock protection to ensure proper operation, rotary switch operation and transient voltage surge suppression. Systems are supplied in a matching cabinet or wall mounted cabinet. These systems are recommended for maintenance purposes to prevent accidental removal of power from the loads and to allow for complete power removal from the UPS system for safety considerations. Bypass with optional TVSS filter Standard Bypass system Rotary Bypass system Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 23 UPSmon Plus Data and software protection UPSmon Plus prevents your computer from crashing during a power failure. If the UPS’s battery runs low, in the case of power failure, UPSmon Plus will detect this and perform an orderly shutdown of your computer before the battery runs out. The auto-shutoff feature is also used to perform scheduled shutdown and startup of your computer during normal operations. With the use of your computer modem, UPSmon Plus can send an event code to your pager to notify you of a power related event on your system. A data recorder is also featured that records power data in a graphic form to facilitate analysis of power quality conditions. UPSmon Plus Communications: RS232 Bi-Directional Operating Systems Supported: Microsoft Windows 95/98/ME/ NT/2000/XP UPSmon Plus Network Data and network software protection UPSmon Plus Network lets you monitor and manage multiple UPS’s through your TCP\IP network from a central location. Using your network UPSmon Plus Network can auto-shutdown an unlimited number of computers in the event of a power failure. The e-mail and pager features can notify you of a power event. The Redundant UPS monitoring feature permits two or more redundant UPS’s to be monitored. If one redundant UPS fails or is taken off-line for maintenance, UPSmon Plus Network still monitors the back-up UPS and provides auto-shutdown protection in the case of a power failure. UPSmon Plus Network Communications: RS232 Bi-Directional and TCP/IP Operating Systems Supported: Microsoft Windows95/98/ME/ NT/2000/XP Main UPS management screen Main UPSmon Software screen Set actions to trigger on power events UPS power management scheduler Power Quality data analysis Individual UPS’s status can also be viewed ACTIVITY MONITORING SOFTWARE REPORT SCREENS .NetPower SNMP Adapter Paging setup screen UPSilon 2000 Data and software protection for the Network UPSilon 2000 lets you monitor local UPS’s as well as remote units by TCP/IP from your central location. UPSilon 2000 can be configured to automatically send e-mails when an event occurs such as a power outage. When an event occurs, it can also call a pager with the use of a modem. The display is a real time display of the graphical display of UPS status including input/output voltage, frequency, load, temperature and capacity. UPSilon 2000 will shutdown the system in a safe fashion before the batteries run out and can also broadcast messages to remote computers running ClientMate (included) and even send them commands to shutdown. INTEGRATED INTELLIGENT POWER MANAGEMENT (IIPM): The IIPM packages are comprised of the SNMP Agent, an SNMP adapter and onEvent. These are available to efficiently control and manage the GES series UPS’s. Aside from running on Windows 95/98/2000 and Windows NT, the excellent network management features let you easily manage over the Internet/Intranet using TCP/IP and Ethernet. IIPM Features: IIPM features remote monitoring and control via a TCP/IP network and provides a hierarchical architecture to manage your UPS’s. It also features notification via e-mail, pager, audible alarm or broadcast and graceful graphics for monitoring and displaying the real-time status of your UPS. IIPM also provides remote shutdown, file saving and password protection. UPSilon 2000 Communications: RS232 Bi-Directional and TCP/IP Operating System Supported: Microsoft Windows products and Linux OPTIONAL: UPSilon for Unix Specifications are subject to change without notice to reflect upgrades and improvement in technology. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 24 Three ∅ In/Out Industrial/Commercial “NFC” Series FREQUENCY CONVERTERS: 50, 60, or 400Hz Input Frequency / 50, 60, or 400Hz User Defined Output Frequency The Always On™ NFC Series Frequency Converters are manufactured to provide clean, regulated and controlled power at the customer specified voltage and frequency. Based on the Always On™ NX Series, the NFC Series provides clean, isolated, reliable and consistent power to all critical loads at the expected levels required. The NFC Series Frequency Converters are intelligent, dual conversion, on-line, three phase systems for centralized frequency conversion, power protection and distribution. The “dual conversion” means AC utility is converted into DC power which, in turn, charges the batteries and supplies the inverter, which inverts the DC power back into highly regulated and isolated AC power supplied at a user defined frequency (50, 60, or 400Hz). This continuous on-line Frequency Converter is available in models from 10kVA up to 250kVA. This dual conversion prevents power aberrations from affecting the connected loads. The NFC Series Frequency Converters provide reliable and robust protection and frequency conversion, allowing for reliable and protected power to be available for all specific and critical loads. Features and Benefits Frequency Conversion: This permits the user to configure a system with any input voltage (208, 480 or 600) and input frequency (50, 60, or 400Hz) with any output voltage (208/120, 480/277 or 600/347) and output frequency (50, 60 or 400Hz), independent of the input configuration. Full Galvanic Isolation: Full Galvanic Isolation provides a completely isolated and referenced output. This isolation protection provides a proven solution to problems created by induced voltages affecting the critical loads. Since the output circuit to the load is completely isolated and no noise induced on the neutral can permeate to the loads, systems operate in a more reliable fashion. Also, this type of protection increases the life span of equipment by eliminating noise, which breaks down components. Modular Design: Each major component (inverter, rectifier and static switch) on the NFC Series Frequency Converters are installed on slide-out modules. This allows for quick repair (mean time to repair of >30 minutes) and easy field upgradability. High efficiency: Thanks to IGBT technology, the NFC Series Frequency Converters provide high efficiency (up to 94.5%). This, combined with IPRO, results in the most cost-efficient and reliable UPS solution in the industry. Fully digital: DSP (Digital Signal Processor), flash memory and SVM strategy are the technology corner stones of the new age of power quality and reliability. Extremely flexible: The NFC Series Frequency Converters offer tailor-made power protection to comply with your individual installation requirements. Options include a passive filter, a 12-pulse rectifier and a Smart Panel (SP). In addition, a comprehensive software suite can be added for mission control and data protection. Optional Battery Banks: Always On™ has also allowed for the option of back-up time to be added to the system to eliminate the need of purchasing a UPS system and a frequency converter. This runtime package will allow for UPS-like operation at a user defined frequency (50, 60, or 400Hz). FOR ALWAYS ON™ UPC ORDER CODES, VISIT WWW.ALWAYSON.COM. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 25 Three ∅ In/Out “NFC” Series FREQUENCY CONVERTERS: 50, 60, or 400Hz Input Frequency / 50, 60, or 400Hz User Defined Output Frequency 10kVA - 250kVA GENERAL DATA Topology True On-Line, Dual Conversion Nominal output at PF=0.8 kVA 10 15 20 30 40 50 60 80 100 160 100% load, 0.9 PF % 91 91 91 91 91.5 92 92 92.5 92.5 93 93 50% load, 0.9 PF True galvanic isolation from input to output % 89 89 89 89 89 91 Yes 91 91 91 92 92 3,070 (0.9) 3,510 (1.0) 4,440 (1.3) 6,480 (1.9) 8,870 (2.6) 10,200 (3.0) 11,900 (3.5) 15,700 (4.6) 18,400 (5.4) 29,700 (8.7) 44,360 (13) Overall efficiency Heat rejection at 100% load, 0.9PF and charged battery Audible noise level (at 1 m) BTU/hr (kW) < 65 at 1m maximum dB (A) UPS Operating temperature range Battery o o o o o o o -15 C to +50 C (5 F to 122 F) o o o o 0 C to 40 C (32 F to 104 F) (VRLA) Storage time is 6 months at 25 C (77 F) Higher temperatures reduce battery storage time 0% to 90%, non-condensing o o <1,500m (5,000ft.) No derating Type Indoor (NEMA 1) [Optional drip shield available] [other configurations available] Safety Internal dead front construction Cooling Forced air (bottom to top) Colour Manufacturer colour (ivory) Rigging Installation o o Without Derating Enclosure o Battery Relative Humidity Maximum Altitude o Optimum 20 C to 25 C (68 F to 77 F) Higher temperatures reduce battery life expectancy UPS Storage temperature range < 67 at 1m maximum o 0 C to 40 C (32 F to 104 F) Mounting Installation and maintenance access Conduit access Standards Suitable for handling by forklift Casters and Floor mounting brackets Front access required for normal maintenance Bottom entry standard [Optional top entry] UL 1778, IEC 62040, FCC Class A, EN50091-1, -2 4kV contact / 8kV air discharge Electrostatic discharge immunity Standard Configuration Stand-alone IPRO - up to 8 units may be paralleled for redundancy or capacity Optional Specifications are subject to change without notice to reflect upgrades and improvement in technology. “NFC” Series Frequency Converter Block Diagram 7 1 2 3 4 5 6 7 FB F1 Lb L In Rectifier Inverter Output Isolation Transformer Output to Load Battery Bank Battery Contactor AC Utility Battery Fuses or Circuit Breaker AC Input Fuses or Circuit Breaker Battery Line Input Line FOR ALWAYS ON™ UPC ORDER CODES, VISIT WWW.ALWAYSON.COM. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 26 250 “TVSS” POWER PROTECTION Products may not necessarily be as illustrated. The Always On™ “ESE” TVSS filter is designed to protect, at the power panel, against externally and internally produced power aberrations, massive impulses, lightning induced effects and interference associated with low frequency harmonics and situations caused by accidents and/or failures in the electrical utility system. It is also totally compatible with all operating loads, including high frequency power supplies and constant current loads controlled by electronic switches. APPLICATIONS: Electrical Service Entrance filters protect the electronic and electrical equipment in the building by supplying power protection at the main and sub-panel locations. PROTECTION: Our ESE’s offer high end protection for industrial and commercial environments and our specifically designed and tuned circuitry provides protection against all potentially dangerous electrical aberrations. They eliminate and attenuate to safe levels common and normal mode noise, massive surge impulses, indirect lightning strikes and their effects, interference associated with low frequency harmonics, spikes and transients, as well as problems associated with electrical utility failures caused by accidents, storms, etc. Electrical and electronic equipment create their own power aberrations, which creates problems for other loads and equipment ‘downstream’. These aberrations will travel down the power bus to the power panels, where they propagate to other loads via other branch circuits. By installing Always On™ ESE power panel protection devices, these problems will not occur. Always On™ ESE Power protection offers TWO Methods of Protection 1) For all New Residential, Commercial and Industrial Construction: The ESE protects electronic equipment in new buildings (security, environmental, networking, communications, appliances, systems, etc.) from potentially destructive and disruptive externally generated power spikes and transients, massive surges, indirect lightning strikes, low frequency harmonics and common and normal mode noise. 2) For all Commercial and Industrial Retrofits: In commercial and industrial environments, the ESE offers the same features as above and protects ‘downstream’ branch panels from externally and internally generated power aberrations such as spikes, transients, massive surges, low frequency harmonics and common and normal mode noise. STOP THE PROBLEMS BEFORE THEY CAN OCCUR. ELIMINATE ALL POTENTIAL PROBLEM CAUSING AND DAMAGING POWER ABERRATIONS BY HAVING AN ALWAYS ON™ ESE FILTER INSTALLED. FEATURES: The ESE features self-diagnostics, LED indicators and removable fuses per phase, which eliminate DEDICATED and costly 3 phase panel breakers. OPTIONAL: The ESE also features optional visual and audible alarms, form C contacts for remote monitoring, a surge counter, which indicates the number of high energy, potentially damaging hits on a continual basis, and a flush mount container. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 27 “TVSS” POWER PROTECTION SPECIFICATIONS Frequency: Voltages: Phases: Protection Modes: Technology: Insertion Loss: Bandwidth: Response Time Standards: 50/60Hz 208, 240, 480, 600 (other voltages available) Wye or Delta - Three phase and Single phase 10 for 3 ∅ wye, 6 for 3 ∅ delta, 5 for 2 ∅ wye Bi-Directional Parallel Nominal 60dB, [email protected] 10kHz-50MHz or 180Hz-50MHz Constant / Instantaneous Surge Current Sink Current Capacity / Ø: Operating Humidity: Operating Temp: Warranty: Enclosure: Weight: Optional: UL1449 Rev. 1998 (TVSS) Peak 60kA to 600kA per phase 25A 0-97% (non-condensing) -40ºC to +65ºC 10 years NEMA 12 (or Optional NEMA 4) Flange Mount 14”x12”x6” inches 13.6kg / 30lbs (Approx) DC - Dry Contact (Form “C”) Communications SC - Surge Counter (LCD Display) FM - Flush Mount Container (DIM 12”x12”x6”) FT - Fault Test Button Specifications are subject to change without notice to reflect upgrades and improvement in technology. Description of Model Number 208 Y ESE 200K Model Type ESE 60K* 100K 120K 160K 200K 250K 300K 400K 500K 600K 60kA per Phase 100kA per Phase 120kA per Phase 160kA per Phase 200kA per Phase 250kA per Phase 300kA per Phase 400kA per Phase 500kA per Phase 600kA per Phase (DC SC FM FT - Optional Configuration Wye or Delta*** ***Contact manufacturer for more information on Delta version **Other voltage options available consult manufacturer FOR ALL UPC ORDER CODES, VISIT WWW.ALWAYSON.COM. *Note: 60K version is for residential use and comes in the 240Volt / Y configuration only. It is not recommended for commercial or industrial applications. EXAMPLES: MODEL ESE ESE ESE SURGE CURRENT 60K 250K 500K VOLTAGE 240 480 600 Y or D OPTION Y D Y DCSC MODEL # ESE-60K-240Y (SHP) ESE-250K-480D ESE-500K-600Y-DCSC Surge Current: 60K, 100K to 600K 208/240/480/600 VOLTS Y - Neutral wire required (Wye type transformer) D - Neutral wire not required (Delta type transformer) DC - Dry Contact Communication SC - Surge Counter FM - Flush Mount Container FT - Fault Test Button Optional Additional Cost Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 28 “TVSS” POWER PROTECTION Reference Sheet for the Electrical Service Entrance Filter Application Residential (Smart Home) and Multi-residential Complexes Model # ESE-60K-240Y [2∅] (SHP) ESE-100K-208Y [3∅] (other voltages available) Panel Size Up to 200A Above 200A Commercial (Office, Retail, etc.) Model # ESE-100K-208Y (DCSC) (Optional) [3∅] (other voltages available) ESE-160K-208Y (DCSC) (Optional) [3∅] (other voltages available) ESE-200K-208Y (DCSC) (Optional) [3∅] (other voltages available) Panel Size Up to 2000A Up to 3000A Above 3000A Industrial ESE Sizing Chart for Industrial Environments 1000A Panel Size 2000A 3000A 4000A 5000A Consult manufacturer for panels exceeding 5000A or 200hp connected. For further specifications on our ESE’s, please visit our website at www.alwayson.com or contact customer service at [email protected] or toll-free at 1-877-259-2976, Ext. 451. ESE 100K ESE 160K ESE 200K ESE 250K ESE Size ESE 300K ESE 400K ESE 500K ESE 600K 0 20hp 40hp 50 60hp 100hp 80hp 120hp Total Horsepower 100 150 140hp 160hp 200 180hp 200hp 250 Base “ESE” size on panel size or Total Horsepower rating. (Use the larger of the “ESE’s” specified). FOR ALWAYS ON™ UPC ORDER CODES, VISIT WWW.ALWAYSON.COM. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 29 FOR ALL “PLC” APPLICATIONS A/C POWER AND DATA LINE PROTECTION IN ONE CONVENIENT BOX Today’s competitive markets require all industrial equipment to function at maximum performance. Lower profits require higher yields or production. This is achieved by maintaining production equipment to run at its optimum level. Increased production means increased profits. The Always On™ “PLC” 2+2 and 2+0 Transient Voltage Surge Suppressor (TVSS) and data line filter will provide today’s users and OEM’s with the ultimate protection required by today’s automated industries. Always On™ has 25 years in the noise suppression and power quality industry, providing us the knowledge base required to remain on the cutting edge of the power protection industry. User resettable breaker on all models APPLICATIONS: Among other applications, the PLC Protector can be applied to PLC’s, robotics, CAD/CAM, alarm systems, scanners, controllers, medical equipment and virtually all microprocessor-based ”critical” equipment. USERS: Typical PLC Protector users include the oil industry, refineries, the pulp and paper industry, the textile industry, water and sewer treatment plants, the petrochemical industry, the food processing industry and virtually all types of manufacturers. FEATURES / BENEFITS: Series Hybrid Design Sine wave tracking TVSS technology ensures fast and immediate attenuation of the harmful spikes, transients and both common and normal mode noise. The added data line filter ensures that the 2+2 Filter will protect the attached network/communication link from all potential problems. The Always On™ 2+2 filter is the only filter that offers all modes of protection on both the power line and the data line. The Always On™ 2+2 one-two punch will guarantee maximum runtimes for your equipment, resulting in higher production and profits, while decreasing downtime and equipment repair costs. Suppression / Attenuation The “cutting edge” technology contained in the Always On™ 2+2 and 2+0 filters allow normal mode noise attenuation up to 85dB and for common mode noise attenuation up to 50dB. It filters bandwidths of 10kHz to 100MHz, with a total peak surge current of 32,500 amps, while providing a response time of less than 1 nanosecond. Functioning Indicator The easily seen three colour LED informs the user of the working status of the Always On™ 2+2 and 2+0 filter. Optional Communications Form A, B or C contacts allow the user to monitor the status of the 2+2 or 2+0 filter from a remote location. Mounting Options The 2+2 and 2+0 come standard with J-Rail or an optional flange mounting is available. Product Warranty Always On™ 2+2 and 2+0 filters are warranted against failure for two years (exchange or repair warranty). 5-Year User Guarantee Always On™ guarantees against electrical damage to the protected power supplies by power aberrations for 5 years. Conclusion The “PLC” 2+2 and 2+0 filters increase up-times to the maximum, which increases production and results in higher profits. It also offers substantial savings through decreased down-time and decreased repair costs. FOR ALWAYS ON™ UPC ORDER CODES, VISIT WWW.ALWAYSON.COM. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 30 TVSS AND DATA LINE FILTER TVSS FILTERS THREE WIRE GROUNDED / TWO WIRE UNGROUNDED DATA LINE FILTERS – THREE AND FOUR WIRE DATA BUS PROTECTION NOW 4 TYPES OF HIGH END PROTECTION IN ONE BOX A/C POWER CONDITIONING (IN BOTH THE TWO PLUS AND TWO PLUS TWO) SURGE PROTECTION UTILIZING TVSS / HYBRID DESIGN Specifications: 3 WIRE GROUNDED 2 WIRE UNGROUNDED Operating Voltage Power Rating Amperage Frequency Protection Modes Maximum Clamping Voltage Noise Attenuation: normal mode common mode Filter Band Width Total Peak Surge Current Joules Response Time Indicators Options 120VAC Single Phase 360VA/600VA/1200VA/1800VA 3/5/10/15 50/60Hz L-N, L-G, N-G 150V 85dB @ 100kHz 50dB @ 5MHz 10kHz to 100 MHz up to 32,500A up to 750 joules < 1 nanosecond Status and fault LED Dry contacts (for remote monitoring) 120VACSingle Phase 360VA/600VA/1200VA/1800VA 3/5/10/15 50/60Hz L-N 150V 75dB @ 100kHz 10kHz to 100 MHz up to 13,000A up to 750 joules < 1 nanosecond Status and fault LED Dry contacts (for remote monitoring) DATA LINE PROTECTION (TWO PLUS TWO ONLY) This solid state semi-conductor series offers surge protection for line to line and lines A, B, common and shield to ground. It is designed for 3 wire and 4 wire data bus communications that require approximately 5VDC difference between line and line. It is compatible with DeviceNet, Data Highway Plus, Modbus Plus, Genius Bus, Simatic Net, Profibus, CompoBus/S, RS485, RS422, Twisted Pair, 3 Wire and Industrial Networks up to 100Mb/sec. Strike Breakdown Voltage Maximum DC Operating Voltage Clamping Voltage Maximum Surge Current Maximum Capacitance A-B Lines Tested to UL497B 13V @ 100V/uSec, 10.5V @ 100V/Sec 9.6VDC 81V DeviceNet 1kA Includes 24VDC Bus protection L-L 2.9pF, L-G 73pF ORDERING INFORMATION: PHYSICAL DATA (BOTH) DIN RAIL/ FLANGE MOUNT CONTAINER Operating Temperature: -40 to +60 C Dimensions 110 x 75 x 110mm (4.375 x 2.75 x 4.375) inches Weight 2kg / 4.5lbs Specifications are subject to change without notice to reflect upgrades and improvement in technology. Description of Model Number PLC Model Style PLC 2+2 Model Type 2+2 2+0 120 15 AC Voltage Current Rating AC Filter 3, 5, 10, 15 AC 120 240 DP VOLTS AMPS 120 120 120 120 220 220 220 220 3 5 10 15 3 5 10 15 UPC Order Codes PLC 2 Plus PLC 2 Plus 2 825433 70000 825433 71000 825433 70010 825433 71010 825433 70020 825433 71020 825433 70030 825433 71030 825433 70110 825433 71101 825433 70120 825433 71111 825433 70130 825433 71121 825433 70140 825433 71131 DCA Data and VDC Filter Dry Contacts DCA DP (2+2 only) DCB DCC (2+0 only) FOR MORE INFORMATION CALL CUSTOMER SERVICE TOLL-FREE AT 1-877-259-2976 Ext. 451. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 31 Always On™ UPS Systems Inc. is not your typical manufacturer. We provide engineered solutions to fit unique applications and customer requests. Some of our engineered solutions are shown below. Side Mount UPS System Din Rail UPS System NEMA 4X UPS System Pole Mount UPS System Bypass with Optional TVSS Filter PLC Communication Interface Rotary Bypass System DC-UPS System Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 32 TTF/ILF-12015 WITH OPTIONAL BY-PASS SWITCH The Always On™ TTF/ILF (Toroidal Isolating Line Filter) combines a low-pass series filter with a toroidal isolation transformer. The TTF/ILF provides for total protection against all power aberrations and eliminates any troublesome constant voltages which may exist between neutral and ground in some electrical configurations. It is totally compatible with all operating loads including high frequency switching power supplies. Some optional features that can be added are the manual by-pass switch or an automatic bypass switch. The manual bypass switch will transfer the load from UPS supplied power to a filtered and isolated AC utility upon user operated switching. This will allow for removal of the UPS system without powering down or exposing your critical loads. The automatic by-pass switch will automatically transfer the load from UPS supplied power in the event of a premature shutdown for whatever reason without powering down your critical loads. The TTF/ILF corrects ground fault problems and eliminates neutral voltages by re-establishing the “zero” volt ground reference point. It provides excellent noise protection, eliminating problems caused by normal mode and common mode noise, as well as other electrical aberrations such as: transients, spikes, surges harmonics and lightning induced voltages. APPLICATIONS: Computers, Laser Printers, Copiers, Point of Sale Terminals, Medical Instruments, PLC’s, Process Instruments, CAD/CAM/CIM & Robotics. PROTECTS FROM: Reverse Polarity, Spikes, Surges, Transients, RFI/EMI Interference, Common/Normal Mode Noise, Direct/Indirect Lightning Effects, and Voltage between Neutral and Ground. SPECIFICATIONS: Frequency: Voltage: Amperage: VA Rating: Noise Protection Mode: Technology: Insertion Loss: Band Width: Response Time: Standards: Total Peak Surge Current: Joules: Leakage Current: Operating Humidity: Operating Temp: Bypass Mode (TTF/ILF-12015-BP only): Warranty: Dimensions: Weight: Wall Mount: 50/60Hz up to/240V; 1 ; Wye 15A @ 120V, 7A @ 220/240V 1,800VA Maximum Normal Mode (L-N), Common Mode (L-G, N-G) Dual Hybrid Series Filter/ Toroidal Isolation Transformer Nominal 75dB, Mil-Std-220A @ 100kHz; Common Mode 120dB Normal Mode: 10kHz - 100kHz; Common Mode: DC to 100MHz Instantaneous 15A, 120VAC, CSA Certified 26,000A Up to 600 Joules Nominal <250mA (<90mA Hospital Grade) 0-97% (non-condensing) 0°C to +40°C All outputs are powered via utility power. 5 Year 205x356x153 mm (12”x14”x6” Approximately) 20kg (44 lbs) Approximately Standard (Tower model available) TTF/ILF-12015 - 120VAC 15A Isolating Line Filter UPC Order Code - 825433 00800 TTF/ILF-22007 - 220VAC 7A Isolating Line Filter UPC Order Code - 825433 00850 TTF/ILF-12015-BP - 120VAC 15A Isolating Line Filter w/ By-Pass Option UPC Order Code - 825433 00810 TTF/ILF-22007-BP - 220VAC 7A Isolating Line Filter w/ By-Pass Option UPC Order Code - 825433 00851 Specifications are subject to change without notice to reflect upgrades and improvement in technology. Surge / Transient Suppression: ANSI / IEEE C62.41-1992 - REV. 2 (Surge Test) TYPICAL: 120V Filter Input: Output (V) N-G L-L L-G L-N Category A3 Ringwave 100kHz 6000V 200A N/A 45V 47V 41V Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 33 AURORA SINGLE ∅ EMERGENCY LIGHTING INVERTER (ELI) AURORA Series Emergency Lighting AC Inverters are among the most reliable central systems available for emergency lighting and other demanding critical applications. The AURORA Series Emergency Lighting AC Inverters are Dual Conversion, On-line, single-phase, intelligent systems for centralized power protection and distribution. The Dual Conversion means it converts the incoming AC power to DC, charges the batteries, then inverts the DC back into highly regulated isolated AC power. These continuous on-line Emergency Lighting AC Inverters are available in models from 3kW to15kW. The AURORA Series Emergency Lighting AC Inverters provide reliable and constant protection for life safety emergency lighting, and infrastructure applications such as airports, hospitals, and residences. FEATURES AND BENEFITS These ELI’s provide full time self-diagnostics as well as two levels of audible alarms when the unit is operating in battery mode. A manual test function has been incorporated into the input/test breakers that make battery testing a simple and safe procedure. The internal bypass switch allows maintenance on the ELI’s to be performed without interruption of power to the load. The communications port, in conjunction with multi-platform monitoring and control software, enables the unit to be connected to a local or networked computer system. Detailed operating information including voltages, currents, and alarm status is available to the monitoring system. Full Galvanic Isolation: Provides a completely isolated and re-reference output. This isolation protection provides a proven solution to problems created by induced voltages affecting the critical loads. Since the output circuit to the load is completely isolated and no noise induced on the neutral can permeate to the loads, systems operate in a more reliable fashion. Fully digital: CPU control, flash memory, and PWM strategy are the technology corner stones of the new age of power quality and reliability. Extremely flexible: The AURORA Series offers tailor-made power protection to comply with your individual installation requirements. Options include additional runtime, remote monitoring panel, and distribution panels. In addition, a comprehensive software suite can be added for mission control and data protection-covers all your application needs. IMBS: An internal maintenance bypass switch is standard with all AURORA single phase inverter units. EMI suppression: An EMI filter is added to meet the international EMC limits to ensure that no noise will effect or interfere with other equipment connected to the same AC source. High frequency design: The inverter design incorporates high frequency, high efficiency Insulated Gate Bi-polar Transistors (IGBT). A PWM wave, synchronized to the bypass input, triggers the IGBT’s, which invert the DC into AC power required by the loads. This design decreases the number of required components, increases reliability and performance while decreasing acoustic noise, size and weight. Cold start function: The AURORA can be started without the utility AC supply being activated, or present at the input terminal strip because our system is designed with current limiting circuitry, which allows startup of the AURORA on battery DC power. Intelligent charger: The AURORA will perform an automatic monthly recharge (boost charge) of the batteries as well as automatically recharge (boost charge) the batteries when the battery voltage level decreases to approximately 2V/Cell. It makes the batteries stay in good condition. Intelligent battery test: The batteries are tested monthly automatically. When an abnormal condition (low charge rating, or bad battery) is found the user will be informed immediately through alarms on the AURORA systems. MTBF of cooling fans: Long cycling fans will operate at variable speeds necessary which is dependent on the load of the inverter systems increasing the life expectancy of the fan motors. OPTIONS Output Circuit Breakers: Supports normally on or normally off circuit breakers. Additional Run Times: These can be 30, 60, 90, or 120 minutes, other configurations are available. EMBP: External Maintenance Bypass. This device allows the load power to be transferred from the inverter output to the AC supply. Thus the inverter can be completely removed or repaired without interruption of power to the load. RCMP: Remote Control and Monitoring Panel. This option provides remote alarms to indicate the inverter status. SNMP: SNMP adapter to remotely control and monitor the unit via a network or the Internet. RTS: Remote terminal strip Consult manufacturer for other features and options. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 34 AURORA True Sine Wave On-Line Single ∅ Emergency Lighting Inverter AURORA 3KW to 15KW ELI 1Ø Input - 1Ø Output Model Capacity Phase / Frequency Rated Voltage Voltage Range Input Input Current 3 kW 6kVA / 6kW 208 / 29 A 240 / 25 A 277 / 22 A 347 / 18 A Output 208 / 14.4 A 240 / 12.5 A 277 / 10.8 A 347 / 8.6 A 208 / 60 A 240 / 53 A 277 / 45 A 347 / 36 A 208 / 74 A 240 / 64 A 277 / 56 A 347 / 45 A 208 / 113 A 240 / 98 A 277 / 85 A 347 / 66 A 208 / 24 A 240 / 20.8 A 277 / 18.1 A 347 / 14.4 A 208 / 36.1 A 240 / 31.3 A 277 / 27 A 347 / 21.6 A 208 / 48.1 A 240 / 41.7 A 277 / 36.1 A 347 / 28.8 A 208 / 72.1 A 240 / 62.5 A 277 / 54.2 A 347 / 43.2 A 50 Hz / 60 Hz ± 0.5% < 3% Linear Load; < 5% Rectified Load 1 Hz / Second ± 4% (100% Load Change) 110% - 125% for 1 min then switch to bypass 125% - 150% for 10 sec then switch to bypass 3:1 > 85% 0ms Hard-Wired 240 VDC Yes Yes Common & Normal Mode Noise Suppression Frequency THD Slew Rate Transient Response Overload Capacity Crest Factor Efficiency (AC - AC) Transfer Time Outlets DC System DC System Voltage Output Short Abnormal Voltage Protection I / O Noise Protection I / O Spike & Transient Protection Communication Interface Display Audible Alarms Operating Temp. Humidity Environment Audible Noise Elevation Safety Safety Approval EMI / RFI Surge / Transient W x D x H in mm. Physical Data Weight in kg. 208 / 40 A 240 / 35 A 277 / 30 A 347 / 24 A 15 kW 20kVA / 23kW 208 / 240 / 277 / 347 VAC (Single Ø, 2 Wire + G) ± 2% Voltage / Phase Voltage Regulation Maximum Current 5 kW 7.5 kW 10 kW 8kVA / 8kW 10kVA / 12kW 12kVA / 15kW Single Ø (2 Wire + GND) 50 / 60 Hz 208 / 240 / 277 / 347 VAC ± 15% Yes 130 RS 232 / Dry Contact / Optional SNMP or AS400 LCD Indicator Status Panel On Battery, Low Battery, Overload, Fault 0 - 40°C 0% - 95% (Non-Condensing) 55 dBA At 1 Meter from Unit 3,500 meters maximum UL1778, UL924, CSA, C22.2, CSA107.3, NFPA111 FCC Part 15 Class A IEEE C62.41 Cat.A 1120 x 815 x 1800 450 x 725 x 1055 760 150 150 431 Specifications are subject to change without notice to reflect upgrades and improvement in technology. Standard charger size: 3kW to 7.5kW is 5A / 10kW to 15kW is 10A. Other voltage ratings and configurations are available; for order codes, consult manufacturer. Consult manufacturer for available runtimes and more information. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 35 BOREALIS THREE ∅ EMERGENCY LIGHTING INVERTER (ELI) BOREALIS Series Emergency Lighting AC Inverters are among the most reliable systems available for emergency lighting and other demanding critical applications. The BOREALIS Series Emergency Lighting AC Inverters are Dual Conversion, On-line, three-phase, intelligent systems for centralized power protection. These continuous on-line Emergency Lighting AC Inverters are available in models from 8kW up to 48kW. For redundant applications, the BOREALIS Series Emergency Lighting AC Inverters can be installed in parallel, achieving isolated and redundant power protection. Isolated Parallel Redundant Operation (IPRO) is a feature of Always On™ BOREALIS Series Emergency Lighting AC Inverters, whereby the systems are controlled in a true peer-to-peer configuration with redundancy in all critical elements and functions. This advanced technology provides greater system reliability and expandability for mission critical applications. The BOREALIS Series Emergency Lighting AC Inverters provide reliable and constant protection for mission critical emergency lighting, and infrastructure applications such as airports, hospitals, and financial companies. FEATURES AND BENEFITS These ELI’s provide full time self-diagnostics as well as two levels of audible alarms when the unit is operating in battery mode. A manual test switch has been incorporated into the input/test breakers that make testing a simple procedure. The internal bypass switch allows maintenance on the ELI’s to be performed without interruption of power to the load. The communications port, in conjunction with multi-platform monitoring and control software, enables the unit to be connected to a local or networked computer system. Detailed operating information including voltages, currents, and alarm status is available to the monitoring system. Full Galvanic Isolation: Provides a completely isolated and re-reference output. This isolation protection provides a proven solution to problems created by induced voltages affecting the critical loads. Since the output circuit to the load is completely isolated and no noise induced on the neutral can permeate to the loads, systems operate in a more reliable fashion. Fully digital: DSP (Digital Signal Processor), flash memory, and multi-contact strategy are the technology corner stones of the new age of power quality and reliability. Extremely flexible: The BOREALIS Series offers tailor-made power protection to comply with your individual installation requirements. Options include passive filter, 12-pulse rectifier, and distribution panels. IMBS: An internal maintenance bypass switch is standard with all BOREALIS 3 phase inverter units. EMI suppression: An EMI filter is added to meet the international EMC limits to ensure that no noise will effect or interfere with other equipment connected to the same AC source. High frequency design: The three phase BOREALIS design incorporates a full bridge three-phase inverter. This design makes the BOREALIS perform better than other Emergency Lighting AC Inverters in the market when an unbalanced load is connected. Cold start function: The BOREALIS can be started without the utility AC supply being activated, or present at the input terminal strip because our system is designed with current limiting circuitry, which allows Startup of the BOREALIS on battery DC power. Intelligent charger: The BOREALIS will perform an automatic monthly recharge (boost charge) of the batteries as well as automatically recharge (boost charge) the batteries when the battery voltage level decreases to approximately 2V/Cell. It makes the batteries stay in good condition. Intelligent battery test: The batteries are tested monthly automatically. When an abnormal condition (low charge rating, or bad battery) is found the user will be informed immediately through alarms on the BOREALIS systems. MTBF of cooling fans: Long cycling fans will operate at variable speeds necessary which is dependent on the load of the inverter systems increasing the life expectancy of the fan motors. SNMP: SNMP adapter to remotely control and monitor the unit via a network or the Internet. OPTIONS Output Circuit Breakers: Supports normally on or normally off circuit breakers. Additional Run Times: These can be 30, 60, 90, or 120 minutes, other configurations are available. EMBP: External Maintenance Bypass. This device allows the load power to be transferred from the inverter output to the AC supply. Thus the inverter can be completely removed or repaired without interruption of power to the load. RCMP: Remote Control and Monitoring Panel. This option provides remote alarms to indicate the inverter status. RTS: Remote terminal strip Consult manufacturer for other features and options. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 36 BOREALIS True Sine Wave On-Line Three ∅ Emergency Lighting Inverter BOREALIS 8KW to 48KW ELI 3Ø Input - 3Ø Output RECTIFIER Input Voltage Input Range Input Frequency Input Power Factor Normal Input Current(A) (Based on 208VAC) Maximum Input Current(A) (Based on 208VAC) 8kW 12kW 16kW 24kW 32kW 40kW 120/208V 277/480V 347/600V 3 phase 4 wire + G ± 15% 50 / 60 Hz +/- 7% <1 31 47 62 93 124 155 186 39 58 78 116 155 193 232 40kW 48kW 25 30 6 PULSE : 30% 12 PULSE WITH FILTER : 9% 0% - 100% : 20 sec 98% 1% 0.50% Current THD Power Walk In (adjustable) Efficiency Voltage Regulation Ripple Voltage BATTERY Battery Type No. Of Cells Voltage Range Maximum Charge Current (ADC) Battery Low Voltage Battery Low Stop INVERTER DC Input Range Wave Form Output Voltage (Adjustable) Crest Factor Output Power Factor Voltage Regulation 100% Unbalance Load Frequency Lock Range Output Frequency (Free Running) Static Output 48kW 8kW 12kW 5 7.5 8kW 16kW 24kW 32kW Maintenance free Sealed Lead Acid 174 295 – 410VDC 10 15 20 320VDC 295VDC 12kW 16kW 24kW 32kW 40kW 285 – 415VDC Sinusoidal 120/208V 277/480V 347/600V 3 Phase 4 Wire + G 3:01 0.8 +/-1% 45 – 55 Hz / 55 – 65 Hz 50 / 60 Hz + / - 0.1 Hz +/- 1% Voltage recovering to within +/- 1% in 4 cycles Load step 0% - 100% - 0% Tolerance 100% unbalanced load (Ph-N) +/- 2.5% Phase Shift Under 100% Unbalance Load 120° + / - 6% THD (Linear Load) <2% CONTINUOUS < 110% 15 min 110 – 125% 5 min Overload 125 – 150% 30 sec 150% - 170% 10 sec > 170% Efficiency (100% Load) 92% 92% 92% 92% 92% Maximum Output Wattage (kW) 8 12 16 24 32 Specifications are subject to change without notice to reflect upgrades and improvement in technology. 92% 40 48kW 92% 48 Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 37 BOREALIS True Sine Wave On-Line Three ∅ Emergency Lighting Inverter BOREALIS 8KW to 48KW ELI 3Ø Input - 3Ø Output STATIC SWITCH Voltage Range Frequency Range Efficiency Transfer Mains -> Inverter Inverter -> Mains Time Isolation With Output 8kW 12kW 16kW 24kW 32kW +- 20% of input voltage (Line to Neutral) 45 – 55 Hz / 55 – 65 Hz 99.50% 0 ms 0 ms YES 40kW 48kW OVERALL CHARACTERISTICS 8kW 12kW 16kW 24kW 32kW 40kW 48kW Overall Efficiency 90% 90% 90% 90% 90% 90% 90% Maximum Heat Dissipation(kW) 0.79 1.18 1.58 2.37 2.93 3.47 4.17 Temperature 0 – 40°C (32 – 104°F) Operating Environment Humidity 0% - 90% (non–condensing) Altitude <1500 m above sea level Short Circuit Yes Lightning MOV Protections EMC Filter Input & Output Galvanic Isolation Between Input & Output Indications & Alarms LED, LCD, Buzzer Dry Contact Yes Battery Start Yes Data Display By LCD Yes Audible Noise < 65 dBA (AT 1 m) Standards UL 924, UL1778, NFPA111, CSA 107.1, CCMC, BMEC, FCC Part 15 Class A, EN50091-1,-2 550 x 812 x 1600 W x D x H (mm) Physical Data Weight(kg) 380 415 450 580 650 710 850 Specifications are subject to change without notice to reflect upgrades and improvement in technology. Input, output voltages are 3phase 4 wire plus ground (wye) configuration. Other voltage ratings and configurations are available; for order codes, consult manufacturer. Consult manufacturer for available runtimes and more information. Always On™ UPS Systems Canada Inc., #100 - 150 Campion Road, Kelowna, BC Canada V1X 7S8 38
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement