EVS Range - Nortelco

EVS Range - Nortelco
EVS Range
Fluorescent fitting
with diffuser
■
■
■
■
■
■
▼▼▼▼▼
TYPICAL
APPLICATIONS
Refineries
Marine/Offshore
Petrochem/Chemical
Food industry
Dust Areas
Unique design for long operating life
Simple and affordable installation/maintenance
Central double locking system: closing and ingress protection reinforced
Disconnectable gear tray
High lumen output
Automatic switch off on opening
Product characteristics
■
■
■
■
■
■
■
Grey fibreglass reinforced polyester body with polycarbonate injected diffuser
Disconnectable gear tray
White painted metal gear tray with:
- G13 lampholder (bi-pin) or Fa6 (single pin)
- Electronic ballast, power factor 0.98
Power supply: standard 220 to 240V, 50 to 60Hz (other voltages, see options)
One M20 polyamide cable gland
Two M20 polyamide plugs
Set of 2 fixing brackets
CERTIFICATION STANDARD: CENELEC EN 50014, 50017, 50018, 50019, 50281-1-1
EC TYPE EXAMINATION CERTIFICATE: under the new directive 94/9/EC: LCIE 97
ATEX 6001
II 2 G and D, IP6x T6 (85°C) for D
EExed IIC T4 or EExedq IIC T4 (with FaF6 lampholder)
EExeds IIC T4 or EExedqs IIC T4 (with G13 lampholder)
Ingress protection: IP66
Shock resistance: IK09 10 Joules
Glow wire test: 960°C
32
Z.I. - Avenue Henri Beaudelet B.P. 27 - 77831 Ozoir Cedex - France - Tel. +33 (0)1 64 40 27 26 - Fax +33 (0)1 64 40 20 11
Zone 1
+ zone 2
EEx “e”
Increased
safety
Technical specifications
Enclosure
Options:
M20 polyamide cable gland for non-armoured cable,
Ø 10-15mm
M25 polyamide cable gland for non-armoured cable,
Ø 13-19 mm
M20 – M25 metallic cable gland for non-armoured
cable series PE (see page 123)
M20 – M25 metallic cable gland for armoured cable
series PEP (see page 123), with brass continuity plate
Fibreglass reinforced polyester body
Polycarbonate diffuser (protective coating optional)
Ingress rating: IP66 (EN60529), with EPDM cellular gaskets
Stainless steel screws
Brass fixing inserts and nickel chromed brass locking bar
(stainless steel optional)
Temperature
Ambient temperature range: -20°C to +40°C
Surface temperature classification:T4 (gas),T6 85°C (dust)
Terminal block
Up to 6mm2 (rigid wire), 4mm2 (flexible wire)
Standard: terminals supplied for L, N, PE and looping
Options: 3 way through wiring L, N, PE (l max. 16A)
5 way through wiring L1, L2, L3, N, PE (l max. 16A)
Protection class: I
Automatic switch off on opening
Rated voltages
Standard: single / dual tube electronic ballast
AC 220 – 240V, 50 - 60Hz
DC 220 – 240V
Options: twin tube electronic ballast (full range)
20W & 40W versions:
automatic cut-out of failed lamp
Full range AC 120V to 240V, 50 to 60Hz and
DC 120V to 240V
65W version: AC 220V to 240V, 50 to 60Hz
DC 220V to 240V
Photometric
data
90
Lamps (supplied on request)
80
Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k
(other colour temperatures on request)
Fa6 single pin tube T12 Ø 38 coolwhite 4000°k
(other colour temperatures on request)
60
110
100
110
25
50
75
100
125
150
175
200
70
50
100 90
80
70
60
50
40
40
0.68 H + 0.10 T
30
30
Fixing
20
Standard: 2 chromed zinc ceiling mounting brackets
(V015) - New model (2003)
Options:
Stainless steel ceiling mounting brackets (V016)
1 1/4” and 1 1/2” (V018), 2” (V019) chromed zinc pole
mountings
1 1/4” and 1 1/2” (V021), 2” (V022) stainless steel pole
mountings
Steel hinged bracket + cataphoresis (V023)
Rapid ceiling mounting with aluminium clip (V014)
Chromed zinc ceiling suspension hook (V024)
Power factor
Superior to 0.98
Cable entries
Standard: One M20 polyamide cable gland for nonarmoured cable, Ø 8-13mm
Two M20 polyamide plugs
10
0
10
20
For 1000 lm, with 1 lamp
90
1
100
110
25
50
75
100
125
150
175
200
10
80
70
60
50
100 90
80
70
60
50
40
40
0.63 G + 0.07 T
30
30
20
10
0
10
20
For 1000 lm, with 2 lamps
Installation and maintenance instruction leaflet NT 27 available on request
Reference
Bi-pin
Single pin
(G13)
(Fa6)
EVS120
EVS140
EVS165
EVS220
EVS240
EVS265
EVM120
EVM140
EVM165
EVM220
EVM240
EVM265
Rating
Nominal
(in W)
current
1
1
1
2
2
2
Hook (V024)
2
x
x
x
x
x
x
E
(in kg)
18/20
36/40
58/65
18/20
36/40
58/65
0.09
0.17
0.26
0.17
0.33
0.50
785
1370
1670
785
1370
1670
170
170
170
170
170
170
137
137
137
137
137
137
400
700
700
400
700
700
432
900
900
432
900
900
5.5
7.5
9
6.5
8.5
10
A
2 Trous
M8 holes
M8
Prof. 20
20
E
B
D
C
100
18
30
70
D
fl 36
fl 20
60¡
maxi
30
C
Dimensions
Hinged bracket (V023)
20
Weight
B
(in A)
Fixing accessories
2 x fl 9
Dimensions (in mm)
A
M8
fl 9
Fixing bracket and flange
for tubes Ø 1"1/4 and 1"1/2
(V018/V021)
100
Spare parts
004
25
002
M8
007
005
003
41
Brackets
(V015/V016)
25
α
001
004
008
009
~70
Mounting bracket Clip (V014)
2 ovale holes
18x9
ø9
160
200
ø9
60
25
,
2 Ø 8.5
V001
V002
V003
V004
Transparent diffuser
Gasket
Box cover
Complete gear tray*
V005
V006
V007
V008
* Define type, rating and operating voltage
XIN switch
EExe terminal block
Electronic ballast EExd*
G13 bi-pin lampholder
002
V009 Single pin lampholder Fa6
V010 EExde connector
33