REED SD-3007 Humidity/Temperature Datalogger Instruction Manual
Below you will find brief information for Humidity/Temperature Datalogger SD-3007. The SD-3007 instrument is a compact and versatile device that measures humidity, temperature, dew point, and wet bulb temperature. It also features a Type K/J thermocouple thermometer. The device can be used to monitor a variety of environmental conditions and can store data on an SD card for later analysis. The SD-3007 is easy to use and comes with a comprehensive instruction manual.
Advertisement
Advertisement
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Rich Black -
20/20/20/100
Model
SD-3007
Humidity/Temperature
Datalogger
Instruction
Manual
reedinstruments
www.reedinstruments.com
www
1-877-849-2127 | [email protected]
INSTRUMENTS
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Table of Contents
Features ............................................................................................ 3
Specifications ................................................................................3-5
Instrument Description ..................................................................... 6
Operating Instructions .................................................................7-11
Function selection .......................................................................... 7
Humidity/Temperature measurement ............................................. 7
Dew Point measurment.................................................................. 7
Wet Bulb measurement ................................................................. 7
Data Hold ...................................................................................... 8
Data Record (Max., Min. reading) ................................................... 8
Backlight ON/OFF .......................................................................... 9
Datalogger ..................................................................................... 9
Auto Datalogger ........................................................................9-10
Manual Datalogger ....................................................................... 10
Checking the Time ....................................................................... 10
Check Sampling Time Information ................................................ 10
SD Card Data Structure ............................................................... 11
Data Transfer from SD card to Computer ..................................... 11
Advanced Settings ....................................................................12-14
Set Clock Time ............................................................................ 12
Setting the Decimal point on the SD Card .................................... 13
Auto power OFF management ..................................................... 13
Set Beeper Sound ON/OFF ......................................................... 13
Select the Thermometer to Type K or Type J ................................ 13
Select the Temperature unit to °C or °F ........................................ 14
Set sampling time ........................................................................ 14
SD memory card Format ............................................................. 14
PC Serial Interface .......................................................................... 15
System Reset ................................................................................. 16
Yellow - 0/27/100/0
Battery Replacement ...................................................................... 16
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
2
INSTRUMENTS
Features
• Dew point and Wet bulb humidity measurements
• Type K, Type J thermocouple thermometer
• Fast humidity measuring response time
• Real time SD memory card datalogger with a built-in clock and calendar
• No extra software needed, just plug the SD card into the computer and it downloads directly to EXCEL
• SD card capacity: 1 GB to 16 GB
• Easy to read LCD with backlight
• Auto power off or manual power off
• Data hold, record max. and min. reading
• High accuracy microcomputer circuit
• Power by UM3/AA (1.5 V) x 6 batteries
• USB/RS232 Computer interface
• Separated probe for easy measurements of multiple environments
• Automatic temperature compensation for the anemometer and type
K/J thermometer
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Specifications
Circuit:
Display:
Custom microprocessor LSI circuit
52mm x 38mm LCD with backlight
Humidity Temp. units: %RH / °C or °F
Dew Point/Wet Bulb units: (°C, °F)
Temperature units:
Auto Sampling Time:
Yellow - 0/27/100/0
Memory Card:
Red - 10/100/100/5
Yellow - 0/27/100/0
(°C, °F)
1, 2, 5, 10, 30, 60, 120, 300, 600, 1800,
3600 seconds
SD memory card, 1 GB to 16 GB
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
3
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Data Output:
Temperature Range:
Résolution:
Accuracy:
USB/RS232 PC computer interface
0-50°C (0-122°F)
0.1°C/0.1°F
± 0.8°C/1.5°F
Operating Temperature: 0-50°C (0-122°F)
Operating Humidity: Less than 85% R.H.
Power Supply:
Weight:
UM3/AA (1.5 V) x 6 batteries
515g/1.13lb
Dimensions:
Includes:
177 x 68 x 45mm (7.0 x 2.7 x 1.9”)
Humidity/Temp. probe
Optional accessories: 4G SD Card (SD-4GB)
Type K thermocouple probe (TP-01)
Soft carrying case (CA-05A)
USB cable (USB-01)
Power adapter (AP-9VA-110V)
Data Acquisition Software (SW-U801-WIN)
Tripod (BS-6)
Visit us at www.reedinstruments.com for more information on our Optional
Accessories, or e-mail us at [email protected]
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Humidity
Range: 5% to 95% RH
Résolution: 0.1% RH
Accuracy: ≥70% RH: ± (3% reading + 1% RH)
Temperature
< 70% RH: ± 3% RH
Range:
Résolution:
Accuracy:
0 - 50°C, 32 - 122°F
Blue - 100/80/30/5
0.1°
±0.8°C, ±1.5°F
Yellow - 0/27/100/0
Blue - 100/80/30/5
Pantone 534 Blue
Black Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
continued...
4
INSTRUMENTS
Dew Point
Range: -25.3°C - 48.9°C, -13.5°F - 120.1°F
Résolution: 0.1°
Wet Bulb
Range: -21.6°C - 50.0°C, -6.9°F - 122.0°F
Résolution: 0.1°
Type K/J thermometer
Sensor Type Résolution
Type K
Type J
0.1°C
0.1°F
0.1°C
0.1°F
Range
-50.0 to 1300.0°C
-50.1 to -100.0°C
-58.0 to 2372.0°F
-58.1 to -148.0°F
-50.0 to 1200.0°C
-50.1 to -100.0°C
-58.0 to 2192.0°F
-58.1 to -148.0°F
Accuracy
± (0.4% + 0.5°C)
± (0.4% + 1°C)
± (0.4% + 1°F)
± (0.4% + 1.8°F)
± (0.4% + 0.5°C)
± (0.4% + 1°C)
± (0.4% + 1°F)
± (0.4 % + 1.8°F)
Above specification tests under the environment RF Field Strength less than 3 V/M & frequency less than 30 MHz only
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Blue - 100/80/30/5
Yellow - 0/27/100/0
For service on this or any other REED product or information on other
REED products, contact REED Instruments at [email protected]
Blue - 100/80/30/5
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
5
INSTRUMENTS
Instrument Description
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
1. Display
2. Power, ESC, & Backlight Button
3. Hold Button, Function Button,
& Next Button
4. REC Button, Enter Button
5. SET Button, Up Button, & Time
Check Button
6. Logger Button, Down Button,
& Sampling Time Check Button
7. Probe input socket
Yellow - 0/27/100/0
8. Type K/J thermometer socket
Red - 10/100/100/5
9. SD card slot
Blue - 100/80/30/5
10. RS232 Output
11. Reset Button
12. AC/DC 9V Power Adapter
Input Socket
13. Battery Compartment/Cover
14. Battery Cover Screws
15. Stand
16. Tripod Fix Nut
17. Probe Plug
18. Probe Handle
19. Probe Head
Pantone 534 Blue
Black Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
6
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Operating Instructions
Function selection
1) Turn on the meter by pressing the Power Button. To turn the meter off, hold the Power Button for over 2 seconds.
2) The meter has 4 measuring functions to choose from: Humidity/
Temp, Dew Point, Wet Bulb, or Type K/J Thermometer. When the meter is on, press and hold the Function Button. The display will flash “rH”, for Humidity/Temperature measurement, “dP” for Dew
Point measurement, “_Et” for Wet Bulb measurement, and “tP” for
Type K/J Thermometer measurement. Release the Function Button to choose the displayed function.
Humidity/Temperature measurement
1) 1) When the meter is off, plug the Probe into the Probe Input
Socket, then power on the meter by pressing the Power Button.
2) Select the “rH” function (see Function Select).
3) Hold the Probe Handle and face the Probe Head against the measuring source. The top part of the Display will show the Humidity value, and the lower part of the Display will show the Temperature value.
Dew Point measurment
1) Select the “dP” function (see Function Select).
2) Hold the Probe Handle and face the Probe Head against the measuring source. The top part of the Display will show the Dew Point value, and the lower part of the Display will show “dP”.
Pantone 534 Blue
Pantone 123 Yellow
Wet Bulb measurement
1) Select the “_Et” function (see Function Select).
Blue - 100/80/30/5
2) Hold the Probe Handle and face the Probe Head against the mea-
Pantone 485 Red
Pantone 123 Yellow value, and the lower part of the Display will show “_Et”.
Blue - 100/80/30/5
Pantone 534 Blue
Black Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
7
INSTRUMENTS
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Type K/J Thermometer measurement
1) Select the “tP” function (see Function Select).
2) Plug the optional Type K or J Thermocouple Probe into the Type
K/J Probe Input Socket. Be sure the Probe is not plugged in.
3) The screen will display a “K”, meaning it is configured for a Type
K thermometer probe. The measured temperature will now be displayed on the display screen. To change the meter to accept a Type
J Probe, please see the Advanced Settings section.
Data Hold
While taking a measurement, press the Hold Button once and the measured value will hold on the screen, and a HOLD symbol will appear.
Press the Hold Button once again will release the data hold function.
Pantone 534 Blue
Pantone 123 Yellow
Data Record (Max., Min. reading)
The data record function records the maximum and minimum readings.
Press the REC Button once to start the Data Record function and a “REC” symbol will appear on the display. With the “REC” symbol on the display:
1) Press the REC Button once, and a ”REC. MAX.” symbol along with the maximum value will appear on the display. To delete the maximum value, press the Hold Button once and the display will show a “REC.” symbol only and execute the memory function continuously.
2) Press the REC Button again, and a “REC. MIN.” symbol along with the minimum value will appear on the display. To delete the minimum value, press the Hold Button once, and the display will show a “REC.” symbol only and execute the memory function continuously.
3) To exit the memory record function, press the REC button for 2 seconds. The display will revert to the current reading.
Blue - 100/80/30/5
Yellow - 0/27/100/0
Pantone 485 Red
Pantone 123 Yellow
Red - 10/100/100/5
Yellow - 0/27/100/0
Pantone 534 Blue
Blue - 100/80/30/5
Black Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
8
INSTRUMENTS
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Backlight ON/OFF
After powering the meter ON, the LCD Backlight will turn on automatically. While taking measurements, press the Backlight Button and the LCD
Backlight will turn off. Press the Backlight Button once again to turn the
LCD Backlight back ON.
Datalogger
Preparation Before Executing the Datalogger Function:
1) Insert the optional SD card into the SD card socket.
2) Before you use an SD card with this meter for the first time, it is recommend to format the SD card. See Advanced Settings section of this manual for instructions.
3) If this is the first time the meter is used you need to adjust the clock. See Advanced Settings section of this manual for instructions.
4) Now you need to set the decimal format. The numerical data structure downloaded to the SD card is defaulted used the “.” as the decimal, for example “20.6” “1000.53”. But in certain countries the
“,” is used as the decimal point, for example “20,6” “1000,53”. See
Advanced Settings section of this manual for instructions on how to change the Decimal Character.
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Auto Datalogger (Set sampling time ≥1 second)
1) Start Datalogging; press the REC Button, and the “REC” symbol will appear on the LCD screen, then press the Logger Button, the
“REC” symbol will flash while the measuring data and time information is being saved in memory. To set the sampling time, and to toggle the beeper sound on or off, refer to the Advanced Settings section of this manual.
2) Pause the Datalogging; while Datalogging, if press the Logger Button once. While paused, the “REC” symbol will stop flashing. Press
Blue - 100/80/30/5
Yellow - 0/27/100/0 the Logger Button again to resume Datalogging, and the “REC” symbol will begin to flash again.
Yellow - 0/27/100/0
Pantone 534 Blue
Blue - 100/80/30/5
continued...
Black Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
9
INSTRUMENTS
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
3) Stop Datalogging; while the Datalogger function is paused, press the REC Button for 2 seconds. The “REC” symbol will disappear indicating the Datalogging function has stopped.
Manual Datalogger (Set sampling time = 0 seconds)
1) Set sampling time is to 0 second; Press the REC Button, and the
“REC” symbol will appear on the LCD screen. Press the Logger
Button, and the “REC” symbol will flash once and one Beep will sound, at the same time the measuring data along the time information will be saved in memory. The lower Display will show the
Position (record) number, which is saved as well.
2) To Change the Position Number; press the Down Button and the lower position number will flash on the display. Press the Up or
Down Buttons to set the Position Number (1 to 99) to help identify the measurement location. The lower Display will show P x (x = 1 to
99). After the position number is selected, press the Enter Button to confirm.
3) Stop Datalogging; press the REC Button for 2 seconds, and the
“REC” symbol will disappear indicating the Datalogging function has stopped.
Checking the Time
During normal functions (not Datalogging), press the Time Check Button and the lower LCD display will show the Year, Month/Date, Hour/Minute.
Check Sampling Time Information
During normal functions (not Datalogging), press the Sampling Button and the lower LCD display will show the Sampling Time Information.
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
10
SD Card Data Structure
1) The first time the SD card is used in the meter, the SD card will generate a folder: HTA01
2) The first time you use the Datalogger, in the folder HTA01, a new file name HTA01001.XLS will be created. The Datalogger will use this file until the Data has reached to 30,000 rows. The meter will then will generate a new file with a subsequent number, for example HTA01002.XLS.
3) The folder HTA01 can hold 99.XLS files. When that number has been reached, the meter will then will generate a new folder with a subsequent number, for example HTA02. Max number of HTA-- folders is 10.
Data Transfer from SD card to Computer (EXCEL Software)
1) After Datalogging, remove the SD card from the SD card slot.
2) Plug in the SD card into the Computer’s SD card slot or insert the
SD card into the optional SD card adapter and connect to your
Computer. Turn your computer on and a folder will appear on your desktop representing you SD card.
3) Open “Microsoft EXCEL”. Download the EXCEL files from the SD
Card to the computer by opening up the SD folder and selecting the desired EXCEL files, and drag-and-drop them onto your Computer. Open the files with EXCEL (File – Open).
4) The EXCEL file will have the following column headers in this order:
Place (Position Number), Date (Year/Month/Day), Time (in 24h clock), Value, and Unit.
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
11
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Advanced Settings
During normal functions (not Datalogging), press and hold the SET Button for 2 seconds to enter the “Advanced Setting” mode. Press the Next Button scroll through eight main functions, shown on the lower display:
dAtE
Set clock time (Year/Month/Date, Hour/Minute/Second)
dEC
Set SD card Decimal character
PoFF
Auto power OFF management
bEEP
Set beeper sound ON/OFF
tYPE
Select the Thermometer to Type K or Type J
t-CF
Select the temperature unit to °C or °F
SP-t
Set sampling time (Hour/Minute/Second)
Sd F
SD memory card Format
While in the “Advanced Setting” function, press the Esc Button to exit and to return to normal functioning.
Set Clock Time
1) When the lower display shows “dAtE”, press the Enter Button.
Use the Up and Down Buttons to adjust the Year. After the desired value is set, press the Enter Button to adjust the Month, Date, Hour,
Minute, and Second values.
2) After all the time values have been set the screen will jump to “SD card Decimal character” setting screen. To exit “Advanced Settings”, press the Esc Button.
Note
: After the time value is set, the internal clock will run even when the power is off, if the battery is under normal conditions.
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
12
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Setting the Decimal point on the SD Card
1) When the lower display shows “dEC”, use the Up or Down Buttons to toggle between “bASIC” (“.” Decimal Point) or “Euro” (“,” Decimal Point).
2) After the Decimal point character has been selected, press the
Enter Button to save the setting as the default. To exit “Advanced
Settings”, press the Esc Button.
Auto power OFF management
1) When the lower display shows “PoFF”, use the Up or Down Buttons to select the value “yES” (Enable Auto Power Off) or “no”
(Disable Auto Power Off.
2) After selecting “yES” or “no”, press the Enter Button to save the setting as the default. To exit “Advanced Settings”, press the Esc
Button.
Set Beeper Sound ON/OFF
1) When the lower display shows “bEEP”, use the Up or Down Buttons to select “yES” (Beeper Sound is ON) or “no” (Beeper Sound is OFF).
2) After selecting “yES” or “no”, press the Enter Button to save the setting as the default. To exit “Advanced Settings”, press the Esc
Button.
Pantone 534 Blue
Pantone 123 Yellow
Select the Thermometer to Type K or Type J
1) When the lower display shows “tYPE”, use the Up or Down Buttons to select “K” (for Type K Thermometer) or “J” (for Type J Thermometer).
2) After selecting “K” or “J”, press the Enter Button to save the setting as the default. To exit “Advanced Settings”, press the Esc Button.
Blue - 100/80/30/5
Yellow - 0/27/100/0
Pantone 485 Red
Pantone 123 Yellow
Red - 10/100/100/5
Yellow - 0/27/100/0
Pantone 534 Blue
Blue - 100/80/30/5
Black Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
13
INSTRUMENTS
Select the Temperature unit to °C or °F
1) When the lower display shows “t-CF”, use the Up or Down Buttons to select “C” (for °C) or “F” (for °F).
2) After selecting “C” or “F”, press the Enter Button to save the setting as the default. To exit “Advanced Settings”, press the Esc
Button.
Set sampling time
1) When the lower display shows “SP-t”, use the Up or Down Buttons to adjust the value to either 0, 1, 2, 5, 10, 30,60, 120, 300, 600,
1800, or 3600 seconds.
2) After the Sampling value is selected, press the press the Enter Button to save the setting as the default. To exit “Advanced Settings”, press the Esc Button.
SD memory card Format
Please Note:
Formatting the SD card erases all data from that SD card.
1) When the lower display shows “Sd F”, use the Up or Down Buttons to select “yES” (format the SD card) or “no” (do not format the SD card).
2) To format your SD card, select “yES” and press the Enter Button.
The Display will show “yES Enter”, to confirm. Press the Enter Button to confirm.
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
14
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
PC Serial Interface
The instrument features an PC output via 3.5 mm terminal. The connector output is a 16 digit data stream which can be utilized to the user’s specific application. An USB RS232 lead with the following connection will be required to link the instrument with the PC serial input.
Meter (3.5mm Jack Plug) PC (9W “D” Connector)
Center Pin Pin 2
Ground/Shield Pin 5
The 16 digit data stream will be displayed in the following format:
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
D10
D11
D12
D13
D14
D15
D0 End Word
D1 to D4 Upper Display reading, D1= LSD, D4= MSB
D5 to D8 D5=? D6=? D7=? D8=?
D9 Decimal Point ( DP) for display
0 = No DP, 1 = 1 DP, 2 = 2 DP, 3 = 3 DP
D10 = 0
D11 = 0
D12 = 0
D13 = 0
D14 = 0
Start Word
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
15
System Reset
If an error occurs, press the Reset Button with a Pin. If the Reset Button does not fix the error, please send in the unit to our Calibration Lab for repair. E-mail [email protected] for more information.
Battery Replacement
1) When the left corner of LCD display shows , it is necessary to replace the battery
2) Loosen the screws of the Battery Cover and remove
3) Remove the batteries and replace with Six DC 1.5 V batteries
(UM3, AA, Alkaline/heavy duty)
4) Make sure the battery cover is properly secured after changing the battery
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Blue - 100/80/30/5
Yellow - 0/27/100/0
For service on this or any other REED product or information on other
Red - 10/100/100/5
REED products, contact REED Instruments at [email protected]
Blue - 100/80/30/5
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
16
INSTRUMENTS
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
Blue - 100/80/30/5
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
17
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
Blue - 100/80/30/5
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
18
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
Blue - 100/80/30/5
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
19
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
Blue - 100/80/30/5
Rich Black -
20/20/20/100 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
20

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Data Logging Capabilities
- Real Time Data Logging
- Temperature Measurement
- Humidity Measurement
- Dew Point Measurement
- Wet Bulb Measurement
- Type K/J Thermocouple Thermometer
- SD Card Data Storage
- USB/RS232 Computer Interface
- Auto Power Off Management