- No category
advertisement
Technical Specification Sheet
Document No. 149-861
February 18, 2015
BACnet PTEC Extended I/O Controller
The BACnet PTEC Extended I/O Controller is designed to allow point expansion for other Siemens controllers and reside on any BACnet control system.
Features
Communicates using BACnet MS/TP protocol for open communications on BACnet MS/TP networks.
BTL listed as a B-ASC device.
Auto-discovery and Auto-addressing over entire
MS/TP network.
Programmable using PPCL.
Setpoints and control parameters assigned and changed locally or remotely.
Setpoints and control parameters stored in
Electrically Erasable Programmable Read Only
Memory (EEPROM)—no battery backup required.
Returns from power failure without operator intervention.
No calibration required, thereby reducing maintenance costs.
Advanced digital room unit for temperature, CO
2
, and relative humidity.
Supports analog and digital room units with relative setpoint adjustment and either absolute or warmer-cooler setpoint adjustments.
Siemens Industry, Inc.
Applications in 550-491PA include a useradjustable temperature offset for the room temperature reading when required for validation purposes.
PID control of HVAC systems to minimize offset and maintain tighter setpoint control.
Unique control algorithms for specific applications.
Plenum rated controller.
Applications
Extended I/O — Application 6696
Custom code using PPCL programming language can be added to provide the flexibility to meet many job specifications. The controller is designed for operation and modification without vendor assistance.
Hardware
Controller Board
The BACnet PTEC Extended I/O Controller consists of an electronic controller assembly.
This controller provides all wiring terminations for system and local communication and power. The cable from the room sensor (purchased separately) connects to an RJ-11 jack on the controller. All other connections are removable terminal blocks. The controller assembly is mounted on a plastic track that mounts directly on the terminal box.
Page 1 of 3
An optional enclosure (P/N 550-002) protects the controller assembly.
An optional Pneumatic Transducer provides control of pneumatic damper and valve actuators.
The controller interfaces with the following external devices:
Floating or analog (0-10 Vdc) control valve and damper actuators
Temperature sensors (room, supply, discharge, duct, immersion, and outside air)
Analog sensors (temperature, pressure, humidity,
CO2)
Service and commissioning tools
Digital input devices (dry contacts from motion sensors, alarm contacts)
Digital output devices (fan, stages of electric heat,
2 position valves, floating control actuators)
Combination Temperature, Carbon Dioxide, and Relative Humidity Models
The Series 2200/2300 range of BACnet
Programmable TEC (PTEC) room units includes temperature only or combination temperature/humidity, temperature/CO2, or temperature/CO2/humidity models. For these models, all measurement variables—CO2, temperature and relative humidity values—are passed digitally to the
PTEC. This information is passed from the room unit through the RJ-11 cable to the RTS port on the
PTEC.
NOTE:
A CO2 power module (product number AQM2200) is also needed for the CO2 sensor option to function.
Extended I/O Controller
Specifications
Dimensions 4-1/8" W × 11-1/4" L × 1-1/2" H
Weight
Controlled Temperature
Accuracy, Heating or
Cooling approx. 3 lbs (1.35 kg)
±1.5°F (0.9°C)
Power Requirements
Operating Range
Power Consumption
Inputs
24 Vac +/-20%, 50 or 60 Hz
7 VA (plus 12 VA per DO)
Analog 1 room temperature sensor
(Optional) 1 setpoint
2 auxiliary temperature sensors
(10K/100K Ω thermistor)
1 selectable 0-10 Vdc/4-20 mA
2 dry contacts Digital
Outputs
Analog
Digital
3 0-10 Vdc, 5 mA maximum
8 DO 24 Vac optically isolated solid state switches @ 0.5 amp
Communications
Remote
Local
Ambient Conditions
BACnet MS/TP (EIA 485), 9600 bps to 76800 bps FLN Trunk
WCIS and PTEC Tool
Shipping & Storage
Temperature
-13°F to 158°F (-25°C to 70°C)
Operating Temperature 32°F to 122°F (0°C to 50°C)
Humidity Range 5% to 95% rh (non-condensing)
Agency Listings
UL Listing cUL Listed
FCC Compliance
BTL Listed
UL 916, PAZX
Canadian Standards C22.2 No.
205-M1983, PAZX7
47 CFR Part 15 as a B-ASC device
Page 2 of 3 Siemens Industry, Inc.
Product Ordering Information
Description Product Part
Number
BACnet PTEC Extended I/O Controller
Large enclosure for electronic controller without damper actuator (long board).
550-491PA
550-002
Document Information
Technical Specification Sheets/Technical
Instructions
Document Part
Number
BACnet Protocol Implementation
Conformance (PIC) Statement
Room Temperature Sensors – Series
2200
149-1033
149-601/149-820
Room Temperature Sensors – Series
2300
AQM2200 Power Module
149-600/149-321
129-111
Series 2200 Carbon Dioxide Room Units 129-609
Series 2300 Carbon Dioxide Room Units 129-608
Duct Temperature Sensor
Low Limit Detection Thermostat
Analog Sensors – 10K/100K Ohm
Thermistor
QXA2601 Condensation Sensor
149-134P25
155-016P25
149-262/149-982
149-931
Technical Specification Sheets/Technical
Instructions
Document Part
Number
Siemens Valves Document Part
Number
154-034 599 Series Zone Valves 2-Way, 3-Way
Zone Valve Electric
599 Series Zone Valves and Actuators –
Modulating, On/Off Spring Return, 2-
Position Control
Siemens Electronic Actuators
154-063
Document Part
Number
155-187P25 OpenAir Electronic Damper Actuators,
GDE/GLB Series Non-spring Return
Rotary 24 Vac – Modulating Control 0 to
10 Vdc
OpenAir Electronic Damper Actuators,
GDE/GLB Series Non-spring Return, 24
Vac Floating Control, Rotary
OpenAir GEB Series Non-spring Return,
24 Vac, 132 lb-in Rotary Electronic
Damper Actuators
155-188P25
155-318P25
Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners.
© 2015 Siemens Industry, Inc.
Siemens Industry, Inc.
Building Technologies Division
1000 Deerfield Parkway
Buffalo Grove, IL 60089-4513
USA
Tel. 1 + 847-215-1000
Your feedback is important to us. If you have comments about this document, please send them to [email protected].
Document No. 149-861
Printed in the USA
Page 3 of 3