Nitrotel Product Catalog 2016
LAN CABLE &
PATCH CABLE
FACE PLATE
MODULES
PATCH PANELS
OPTICAL FIBER
NITROTEL INTERNATIONAL GROUP
Tel: 305.356.6739
E-mail: [email protected]
www.nitrotelgroup.com
PRODUCT
INFORMATION
WORLD OF STRUCTURED CABLING SOLUTIONS
CABINETS
itrotel
Professional Networking Products
www.nitrotelgroup.com
FOR MORE INFORMATION,PLEASE VISIT OUR WEBSITE
www.nitrotelgroup.com
Dedicated to
the global leading manufacturer
of structure cabling
and consumer electronics
FOR MORE INFORMATION,PLEASE VISIT OUR WEBSITE
www.nitrotelgroup.com
1 MONTH
NITROTEL CABLES INSTALLED
WORLDWIDE CAN CIRCLE
AROUND THE EARTH ONCE
Aiming at becoming a global leading solution provider of wisdom city,
intelligent building and smart home.
FOR MORE INFORMATION,PLEASE VISIT OUR WEBSITE
www.nitrotelgroup.com
FOR MORE INFORMATION,PLEASE VISIT OUR WEBSITE
www.nitrotelgroup.com
GROUP
INTRODUCTION
Located in Miami, U.S.A., Nitrotel Group is an investment
holding company which is based on two core industries of
structured cabling and consumer electronics. Established
in 1993 and with development in business model
innovation, management innovation, technology
innovation for over 20 years, Ship Group has become an
international group corporation. With the corporate spirit
of “Faith, Devotion and Pragmatic”, the company has
been selected as one of Region Top 100 Enterprises.
Nitrotel With four steps of capital accumulation, brand
establishment, industry promotion and global operations,
has become the industrial and operational group
corporation based on structured cabling and consumer
electronics, covering the whole value-chain of R & D,
manufacture and brand sales. In 2012, in sales.
Electronic Science & Technology Co. Ltd., one affiliate of
Nitrotel Group, is a national high-tech enterprise. With the
development over 20 years, it has formed a complete
vertical industrial chain of structured cabling, including
over 10 subsidiaries in R&D, manufacture and sale. It has
been a global solution provider of structured cabling, and
its domestic market share has been in the front rank for
many years. Also, this affiliate of Nitrotel Group has
established production bases and logistics centers in
many cities at home and abroad. Its products are
exported to over 100 countries and regions, and its
strategic partners are more than a dozen global leading
electronics companies. Electronic Science &
Technology Co. Ltd. has over 300 professional
technicians, dozens of production lines of data cables,
optical fiber cables, network patch cords, precise
cabinets, communication equipments, security cables
and new plastic materials. Its provincial high-tech R &
D center is mature with abundant engineers, research
and testing equipments, providing high quality
technical services and new pro-duct development
security for customers. The center is able to bear entire
tasks of R & D projects with the wide trial site.
Electronic Science & Technology Co. Ltd. has obtained
many certificates such as ISO9001: 2000, ISO14001,
CCC, TLC, UL, ETL and CE, and introduced large DCM
detector, network analyzer, fluke detector, time domain
reflector, HDMI tester and etc., which provide the
reliable security of product quality for our clients.
U
AL
ITY MANA
E
IS
TERED
ISO
Q
U
AL
01
140
ITY MANA
T
T
G
RE
G
1
900
EN
TERED
M
Q
EN
IS
ISO
M
RE
G
PRODUCT CERTIFICATES
G
E
FOR MORE INFORMATION,PLEASE VISIT OUR WEBSITE
www.nitrotelgroup.com
Company plant
office
R & D Center
dining hall
CONTENTS
STRUCTURE CABLING
001 — 168
1.LAN CABLE
001 — 024
2.PATCH CABLE
025 — 032
3.FACE PLATE
033 — 057
4.MODULES
058 — 062
5.PATCH PANEL
063 — 084
7.MODULAR PLUG
085 — 085
8.NETWORK TOOL
086 — 088
9.OPTICAL FIBER
089 — 109
OPTICAL FIBER
091 — 103
OPTICAL FIBER PATCH CORD
104 — 104
OPTICAL FIBER ADAPTER
workshop
workshop
OPTICAL FIBER DISTRIBUTION BOX
10.CABINET
CABINET
WALL BOX
RACK
CABINET FITTING
workshop
workshop
workshop
workshop
105 — 105
106 — 109
110 — 168
110 — 132
133 — 148
149 — 151
152 — 168
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
FACE PLATE
STRUCTURE CABLING
LAN CABLE & PATCH CORD
MODULES
003 — 003
CAT7 Lan Cable
004 — 005
CAT6A Lan Cable
006 — 011
CAT6 Lan Cable
012 — 014
CAT5E Lan Cable
015 — 017
OTHER Lan Cable
018 — 024
025 — 026
CAT6 Patch Cord
027 — 028
CAT5E Patch Cord
029 — 032
OPTICAL FIBER
CAT6A Patch Cord
PATCH PANELS
CAT7A Lan Cable
PRODUCT CERTIFICATES
CABINETS
page 001
page 002
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
LAN CABLE
STRUCTURE CABLING
LAN CABLE
Standard
Braid
Insulation(skin-foam-skin)
Jacket
Rip Cord
Application
Conductor
Solid Bare Copper 23AWG
Insulation
PE(Skin-Foam-Skin)
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
blue x white, orange x white,
green x white, brown x white
Individual pair shield
aluminum foil, providing 100%
coverage, foil face out
Overall shield
Tinned copper braid
Drain wire
None
Jacket Color
RD
GY
BK
WH
GN
YL
PR
Nominal Transmission Characteristics
IL(max)
(MH)z
(dB)
( d B/100m)
Propagation Delay Skew
Delay(max)
(max)
Conductor
ElectricalCharacteristics
Order information(PartNumber)
NTNC7A_ _SFTP-_
BU
Suitable for structured premises cabling.
For transmission of digital and analogue voice and data
signals.
Especially suitable for all Class F applications.
ISDN,Ethernet 10 Base-T,Fast Ethernet 100 Base-T,
Gigabit Ethernet 1000Base-T ,10G Base-T.(IEEE 802.3).
Token Ring4/16Mbit/s,TP-PMD/TP/DDI 125Mbit/s,ATM
155Mbit/s.(IEEE 802.5 ).
Item OuterJacket Overalldiameter(mm)
P
CMP
8.3±0.3
C
CM
8.3±0.3
R
CMR
8.3±0.3
L
LSZH
8.3±0.3
E
LDPE
8.3±0.3
NEXT (min)
PSNEXT
(min)
ELNEXT
(min)
PSELNEXT
(min)
( n s/100m)
25
(dB)
(dB)
( d B/100m)
( d B/100m)
23.0
3.7
78.0
75.0
78.0
75.0
8
24.5
5.2
547
25
78.0
75.0
77.2
74.2
Solid Bare Copper 23AWG
Insulation
PE(Skin-Foam-Skin)
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
blue x white, orange x white,
green x white, brown x white
Individual pair shield
aluminum foil, providing 100%
coverage, foil face out
Overall shield
Tinned copper braid
Drain wire
None
Order information(PartNumber)
NTNC7_ _SFTP2-_
Jacket Color
BU
RD
GY
BK
WH
YL
GN
PR
Nominal Transmission Characteristics
Frequency
RL (min)
IL(max)
Propagation Delay Skew
Delay(max)
(max)
NEXT (min)
Item OuterJacket Overalldiameter(mm)
P
CMP
(8.5+8.5)±0.3
C
CM
(8.5+8.5)±0.3
R
CMR
(8.5+8.5)±0.3
L
LSZH
(8.5+8.5)±0.3
E
LDPE
(8.5+8.5)±0.3
PSNEXT
(min)
ELNEXT
(min)
PSELNEXT
(min)
25.0
5.8
545
25
78.0
75.0
75.3
72.3
(MH)z
(dB)
( d B/100m)
( d B/100m)
( d B/100m)
543
25
78.0
75.0
71.2
68.2
4
23.0
3.7
( n s/100m)
25
(dB)
7.3
( n s/100m)
552
(dB)
25.0
78.0
75.0
78.0
75.0
20
25.0
8.2
542
25
78.0
75.0
69.3
66.3
8
24.5
5.2
547
25
78.0
75.0
77.2
74.2
25
24.3
9.2
541
25
78.0
75.0
67.3
64.3
10
25.0
5.9
545
25
78.0
75.0
75.3
72.3
31.25
23.6
10.3
540
25
78.0
75.0
65.4
62.4
16
25.0
7.4
543
25
78.0
75.0
71.2
68.2
62.5
21.5
14.6
539
25
75.5
72.5
59.4
56.4
20
25.0
8.3
542
25
78.0
75.0
69.3
66.3
100
20.1
18.5
538
25
72.4
69.4
55.3
52.3
25
24.3
9.3
541
25
78.0
75.0
67.3
64.3
200
18.0
26.5
537
25
67.9
64.9
49.3
46.3
31.25
23.6
10.4
540
25
78.0
75.0
65.4
62.4
250
17.3
29.7
536
25
66.4
63.4
47.3
44.3
62.5
21.5
14.9
539
25
75.5
72.5
59.4
56.4
300
17.3
32.7
536
25
65.2
62.2
45.8
42.8
100
20.1
19.0
538
25
72.4
69.4
55.3
52.3
400
17.3
38.0
536
25
63.4
60.4
43.3
40.3
200
18.0
27.5
537
25
67.9
64.9
49.3
46.3
500
17.3
42.8
536
25
61.9
58.9
41.3
38.3
250
17.3
31.0
536
25
66.4
63.4
47.3
44.3
600
47.1
535
25
60.7
57.7
34.2
536
25
65.2
62.2
45.8
42.8
535
25
59.7
56.7
36.7
na
17.3
51.1
39.7
na
300
700
17.3
na
400
17.3
40.0
536
25
63.4
60.4
43.3
40.3
800
na
54.9
535
25
58.9
55.9
na
na
500
17.3
45.3
536
25
61.9
58.9
41.3
38.3
900
na
58.5
535
25
58.1
55.1
na
na
600
17.3
50.1
535
25
60.7
57.7
39.7
36.7
54.4
na
na
na
57.4
535
1000
61.9
25
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
CABINETS
10
16
OPTICAL FIBER
4
( n s/100m)
552
Impedance:4 - 100MHz 100±15 (ohms).
100 - 200MHz 100±22 (ohms).
200 - 600MHz 100±32 (ohms).
Max. Conductor DC Resistance 20℃:8.4(ohms/100m).
Resistance unbalance (%): max 2.5.
Pair-to-Ground Capacitance Unbalance:330 (pF/100m).
Transfer Impendance:Max10 mohms/[email protected]
Coupling Attenuation: Min 80 dB.
Installation temperature:0~50℃.
Operation temperature:-20~60℃.
Conductor
PATCH PANELS
Impedance:4 - 100MHz 100±15 (ohms).
100 - 200MHz 100±22 (ohms).
200 - 1000MHz 100±32 (ohms).
Max. Conductor DC Resistance 20℃:8.4(ohms/100m).
Resistance unbalance (%):max 2.5.
Pair-to-Ground Capacitance Unbalance:330 (pF/100m).
Transfer Impendance:Max10 mohms/[email protected]
Coupling Attenuation: Min 80 dB.
Installation temperature:0~50℃.
Operation temperature:-20~60℃.
RL (min)
Braid
Insulation(skin-foam-skin)
Jacket
Rip Cord
MODULES
Conductor
ElectricalCharacteristics
Frequency
Conductor
Al-mylar Foil
IEC/ISO 61156-5
ISO/IEC 11801
Application
Suitable for structured premises cabling.
For transmission of digital and analogue voice and data
signals.
Especially suitable for all Class FA applications.
ISDN,Ethernet 10 Base-T,Fast Ethernet 100 Base-T,
Gigabit Ethernet 1000Base-T ,10G Base-T.(IEEE 802.3).
Token Ring4/16Mbit/s,TP-PMD/TP/DDI 125Mbit/s,ATM
155Mbit/s.(IEEE 802.5 ).
page 003
S/FTP Shielded CAT 7 Twisted Pair Installation Cable
Conductor
Al-mylar Foil
IEC/ISO 61156-5
ISO/IEC 11801
FACE PLATE
S/FTP Shielded CAT 7A Twisted Pair Installation Cable
Standard
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
page 004
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
LAN CABLE
STRUCTURE CABLING
LAN CABLE
S/FTP Shielded CAT 6A Twisted Pair Installation Cable
Standard
Standard
Conductor
Al-mylar Foil
Application
Application
Conductor
ElectricalCharacteristics
Conductor
Solid Bare Copper 23AWG
Insulation
PE(Skin-Foam-Skin)
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
blue x white, orange x white,
green x white, brown x white
Individual pair shield
aluminum foil, providing 100%
coverage, foil face out
Overall shield
Tinned copper braid
Drain wire
None
Jacket Color
RD
GY
BK
WH
YL
GN
PR
Item OuterJacket Overalldiameter(mm)
P
CMP
8.3±0.3
C
CM
8.3±0.3
R
CMR
8.3±0.3
L
LSZH
8.3±0.3
E
LDPE
8.3±0.3
Nominal Transmission Characteristics
RL (min)
IL(max)
(MH)z
(dB)
( d B/100m)
Conductor
Solid Bare Copper 23AWG
Insulation
PE(Skin-Foam-Skin)
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
blue x white, orange x white,
green x white, brown x white
Individual pair shield
aluminum foil, providing 100%
coverage, foil face out
Overall shield
Tinned copper braid
Drain wire
Impedance:4 - 100MHz 100±15 (ohms) .
100 - 200MHz 100±22 (ohms).
200 - 500MHz 100±32 (ohms).
Max. Conductor DC Resistance 20℃:8.7(ohms/100m).
Resistance unbalance (%):max 2.5.
Pair-to-Ground Capacitance Unbalance 330 (pF/100m).
Transfer Impendance:Max10 mohms/[email protected]
Coupling Attenuation :Min 80 dB.
Installation temperature:0~50℃.
Operation temperature:-20~60℃.
None
Order information(PartNumber)
NTNC6A_ _SFTP-_
Jacket Color
BU
RD
GY
BK
WH
YL
GN
PR
Item OuterJacket Overalldiameter(mm)
P
CMP
8.3±0.3
C
CM
8.3±0.3
R
CMR
8.3±0.3
L
LSZH
8.3±0.3
E
LDPE
8.3±0.3
Nominal Transmission Characteristics
Propagation Delay Skew
Delay(max)
(max)
NEXT (min)
PSNEXT
(min)
ELNEXT
(min)
PSELNEXT
(min)
( n s/100m)
( n s/100m)
(dB)
(dB)
( d B/100m)
( d B/100m)
Frequency
RL (min)
IL(max)
Propagation Delay Skew
Delay(max)
(max)
NEXT (min)
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
4
23.0
3.7
552
25
78.0
75.0
78.0
75.0
(MH)z
(dB)
( d B/100m)
( d B/100m)
( d B/100m)
5.2
547
25
78.0
75.0
77.2
74.2
1
20.0
2.1
( n s/100m)
45
(dB)
24.5
( n s/100m)
570
(dB)
8
74.3
72.3
67 . 8
64 . 8
10
25.0
5.9
545
25
78.0
75.0
75.3
72.3
4
23.0
3.8
552
45
65.3
63.3
55 . 8
52 . 8
16
25.0
7.4
543
25
78.0
75.0
71.2
68.2
10
25.0
5.9
545
45
59.3
57.3
47 . 8
44 . 7
20
25.0
8.3
542
25
78.0
75.0
69.3
66.3
16
25.0
7.5
543
45
56.2
54.2
43 . 7
40 . 7
25
24.3
9.3
541
25
78.0
75.0
67.3
64.3
20
25.0
8.4
542
45
54.8
52.8
41 . 8
38 . 8
31.25
23.6
10.4
540
25
78.0
75.0
65.4
62.4
31.25
23.6
10.5
540
45
51.9
49.9
37 . 9
34 . 9
62.5
21.5
14.9
539
25
75.5
72.5
59.4
56.4
62.5
21.5
15.0
539
45
47.4
45.4
31 . 9
28 . 9
100
20.1
19.0
538
25
72.4
69.4
55.3
52.3
100
20.1
19.1
538
45
44.3
42.3
27 . 8
24 . 8
200
18.0
27.5
537
25
67.9
64.9
49.3
46.3
200
18.0
27.6
537
45
39.8
37.8
21 . 8
18 . 8
250
17.3
31.0
536
25
66.4
63.4
47.3
44.3
300
17.3
34.3
536
45
37.1
35.1
18 . 3
15 . 3
300
17.3
34.2
536
25
65.2
62.2
45.8
42.8
400
17.3
40.1
536
45
35.3
33.3
15 . 8
12 . 8
400
17.3
40.0
536
25
63.4
60.4
43.3
40.3
500
17.3
45.3
536
45
33.8
31.8
13 . 8
10 . 8
500
17.3
45.3
536
25
61.9
58.9
41.3
38.3
600
17.3
50.1
535
25
60.7
57.7
39.7
36.7
OPTICAL FIBER
Frequency
Conductor
ElectricalCharacteristics
Order information(PartNumber)
NTNC7_ _SFTP-_
BU
Suitable for structured premises cabling.
For transmission of digital and analogue voice and data
signals.
Especially suitable for all Class EA applications.
ISDN,Ethernet 10 Base-T,Fast Ethernet 100 Base-T,Gigabit
Ethernet 1000Base-T ,10G Base-T.(IEEE 802.3).
Token Ring4/16Mbit/s,TP-PMD/TP/DDI 125Mbit/s,
ATM 155Mbit/s.(IEEE 802.5 ).
PATCH PANELS
Impedance: 4 - 100MHz 100±15 (ohms).
100 - 200MHz 100±22 (ohms).
200 - 600MHz 100±32 (ohms).
Max. Conductor DC Resistance 20℃:8.4(ohms/100m).
Resistance unbalance (%) :max 2.5.
Pair-to-Ground Capacitance Unbalance:330 (pF/100m).
Transfer Impendance:Max10 mohms/[email protected]
Coupling Attenuation: Min 80 dB.
Installation temperature:0~50℃.
Operation temperature:-20~60℃.
Braid
Insulation (skin-foam-skin)
Jacket
Rip Cord
MODULES
Suitable for structured premises cabling.
For transmission of digital and analogue voice and data
signals.
Especially suitable for all Class F applications.
ISDN,Ethernet 10 Base-T,Fast Ethernet 100 Base-T,
Gigabit Ethernet 1000Base-T ,10G Base-T.(IEEE 802.3).
Token Ring4/16Mbit/s,TP-PMD/TP/DDI 125Mbit/s,ATM
155Mbit/s.(IEEE 802.5 ).
Conductor
Al-mylar Foil
IEC/ISO 61156-5
ANSI/TIA568C.2
ISO/IEC 11801
Braid
Insulation (skin-foam-skin)
Jacket
Rip Cord
FACE PLATE
S/FTP Shielded CAT 7 Twisted Pair Installation Cable
IEC/ISO 61156-5
ISO/IEC 11801
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
CABINETS
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
page 005
page 006
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
LAN CABLE
Standard
Standard
Conductor
Al-mylar Foil
Conductor
Solid Bare Copper 23AWG
Insulation
PE(Skin-Foam-Skin)
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
blue x white, orange x white,
green x white, brown x white
Individual pair shield
aluminum foil, providing 100%
coverage, foil face out
Overall shield
Tinned copper braid
Drain wire
Tinned copper
Impedance:4 - 100MHz 100±15 (ohms) .
100 - 200MHz 100±22 (ohms).
200 - 500MHz 100±32 (ohms).
Max. Conductor DC Resistance 20℃:8.7(ohms/100m).
Resistance unbalance (%):max 2.5.
Pair-to-Ground Capacitance Unbalance 330 (pF/100m).
Transfer Impendance:Max10 mohms/[email protected]
Installation temperature:0~50℃.
Operation temperature:-20~60℃.
Jacket Color
RD
GY
BK
WH
YL
GN
PR
Nominal Transmission Characteristics
Item OuterJacket Overalldiameter(mm)
P
CMP
8.3±0.3
C
CM
8.3±0.3
R
CMR
8.3±0.3
L
LSZH
8.3±0.3
E
LDPE
8.3±0.3
Impedance:4 - 100MHz 100±15 (ohms) .
100 - 200MHz 100±22 (ohms).
200 - 500MHz 100±32 (ohms).
Max. Conductor DC Resistance 20℃:8.7(ohms/100m).
Resistance unbalance (%):max 2.5.
Pair-to-Ground Capacitance Unbalance 330 (pF/100m).
Transfer Impendance:Max10 mohms/[email protected]
Installation temperature:0~50℃.
Operation temperature:-20~60℃.
PSACR-F
(min)
Frequency
(dB)
(dB)
( d B/100m)
( d B/100m)
74.3
72.3
67.8
64.8
65.3
63.3
55.8
45
59.3
57.3
543
45
56.2
542
45
(MH)z
(dB)
( d B/100m)
1
20.0
2.1
( n s/100m)
570
( n s/100m)
45
4
23.0
3.8
552
45
10
25.0
5.9
545
16
25.0
7.5
20
25.0
8.4
NEXT (min)
Solid Bare Copper 23AWG
Insulation
PE(Skin-Foam-Skin)
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
blue x white, orange x white,
green x white, brown x white
Individual pair shield
aluminum foil, providing 100%
coverage, foil face out
Overall shield
0.40±0.005mm TC
Drain wire
None
Order information(PartNumber)
NTNC6A_ _UFTP-_
Jacket Color
BU
RD
GY
BK
WH
YL
GN
PR
Item OuterJacket Overalldiameter(mm)
P
CMP
8.3±0.3
C
CM
8.3±0.3
R
CMR
8.3±0.3
L
LSZH
8.3±0.3
E
LDPE
8.3±0.3
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
(dB)
(dB)
( d B/100m)
( d B/100m)
74.3
72.3
67.8
64.8
65.3
63.3
55.8
52.8
45
59.3
57.3
47.8
44.8
543
45
56.2
54.2
43.7
40.7
542
45
54.8
52.8
41.8
38.8
Propagation Delay Skew
Delay(max)
(max)
RL (min)
IL(max)
(MH)z
(dB)
( d B/100m)
1
20.0
2.1
( n s/100m)
570
( n s/100m)
45
52.8
4
23.0
3.8
552
45
47.8
44.8
10
25.0
5.9
545
54.2
43.7
40.7
16
25.0
7.5
54.8
52.8
41.8
38.8
20
25.0
8.4
NEXT (min)
31.25
23.6
10.5
540
45
51.9
49.9
37.9
34.9
31.25
23.6
10.5
540
45
51.9
49.9
37.9
34.9
62.5
21.5
15.0
539
45
47.4
45.4
31.9
28.9
62.5
21.5
15.0
539
45
47.4
45.4
31.9
28.9
100
20.1
19.1
538
45
44.3
42.3
27.8
24.8
100
20.1
19.1
538
45
44.3
42.3
27.8
24.8
200
18.0
27.6
537
45
39.8
37.8
21.8
18.8
200
18.0
27.6
537
45
39.8
37.8
21.8
18.8
300
17.3
34.3
536
45
37.1
35.1
18.3
15.3
300
17.3
34.3
536
45
37.1
35.1
18.3
15.3
400
17.3
40.1
536
45
35.3
33.3
15.8
12.8
400
17.3
40.1
536
45
35.3
33.3
15.8
12.8
500
17.3
45.3
536
45
33.8
31.8
13.8
10.8
500
17.3
45.3
536
45
33.8
31.8
13.8
10.8
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
CABINETS
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
OPTICAL FIBER
ACR-F
(min)
IL(max)
Conductor
Nominal Transmission Characteristics
PSNEXT
(min)
Propagation Delay Skew
Delay(max)
(max)
RL (min)
Conductor
ElectricalCharacteristics
Order information(PartNumber)
NTNC6A_ _FFTP-_
BU
Suitable for structured premises cabling.
For transmission of digital and analogue voice and data
signals.
Especially suitable for all Class EA applications.
ISDN,Ethernet 10 Base-T,Fast Ethernet 100 Base-T,
Gigabit Ethernet 1000Base-T ,10G Base-T.(IEEE 802.3).
Token Ring4/16Mbit/s,TP-PMD/TP/DDI 125Mbit/s,
ATM 155Mbit/s.(IEEE 802.5 ).
PATCH PANELS
Conductor
ElectricalCharacteristics
Frequency
Application
MODULES
Suitable for structured premises cabling.
For transmission of digital and analogue voice and data
signals.
Especially suitable for all Class EA applications.
ISDN,Ethernet 10 Base-T,Fast Ethernet 100 Base-T,
Gigabit Ethernet 1000Base-T ,10G Base-T.(IEEE 802.3).
Token Ring4/16Mbit/s,TP-PMD/TP/DDI 125Mbit/s,
ATM 155Mbit/s.(IEEE 802.5 ).
Conductor
Al-mylar Foil
Drain Wire
Insulation(skin-foam-skin)
Jacket
Rip Cord
IEC/ISO 61156-5
ANSI/TIA568C.2
ISO/IEC 11801
Insulation(skin-foam-skin)
Jacket
Drain Wire
Rip Cord
FACE PLATE
U/FTP Shielded CAT6A Twisted Pair Installation Cable
Application
page 007
STRUCTURE CABLING
LAN CABLE
F/FTP Shielded CAT6A Twisted Pair Installation Cable
IEC/ISO 61156-5
ANSI/TIA568C.2
ISO/IEC 11801
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
page 008
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
LAN CABLE
STRUCTURE CABLING
LAN CABLE
U/UTP unshielded CAT6A Twisted PairInstallation Cable
Application
Application
Suitable for structured premises cabling.
For transmission of digital and analogue voice and data
signals.
Especially suitable for all Class EA applications.
ISDN,Ethernet 10 Base-T,Fast Ethernet 100 Base-T,
Gigabit Ethernet 1000Base-T ,10G Base-T.(IEEE 802.3).
Token Ring4/16Mbit/s,TP-PMD/TP/DDI 125Mbit/s,
ATM 155Mbit/s.(IEEE 802.5 ).
Conductor
Conductor
Solid Bare Copper 23AWG
Insulation
HDPE
8, twisted in 4 pairs
Color code
blue x white, orange x white,
green x white, brown x white
Individual pair shield
Overall shield
None
Aluminum foil, providing 100%
coverage, foil face out.
Drain wire
Tinned copper
RD
GY
BK
WH
YL
GN
PR
IL(max)
DOP(max)
Delay Skew
(max)
NEXT (min)
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
None
Overall shield
None
Drain wire
None
Order information(PartNumber)
NTNC6A_ _ - _
Jacket Color
Jacket Color
BU
Solid Bare Copper 23AWG
Insulation
BU
RD
GY
BK
WH
YL
GN
PR
Item OuterJacket Overalldiameter(mm)
Item OuterJacket Overalldiameter(mm)
P
CMP
7.6±0.2
C
CM
7.6±0.2
R
CMR
7.6±0.2
L
LSZH
7.6±0.2
E
LDPE
7.6±0.2
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
(MH)z
(dB)
( d B/100m)
( d B/100m)
( d B/100m)
2.1
( n s/100m)
45
(dB)
20.0
( n s/100m)
570
(dB)
1
74.3
72.3
67.8
64.8
4
23.0
3.8
552
45
65.3
63.3
55.8
52.8
10
25.0
6.0
545.4
45
59.3
57.3
47.8
44.8
16
25.0
7.6
543
45
56.2
54.2
43.7
40.7
20
25.0
8.5
542.1
45
54.8
52.8
41.8
38.8
31.25
25.0
10.7
540.4
45
51.9
49.9
37.9
34.9
62.5
21.5
15.4
538.6
45
47.4
45.4
31.9
28.9
100
20.1
19.8
537.6
45
44.3
42.3
27.8
24.8
200
18.0
29.0
536.1
45
39.8
37.8
21.8
18.8
300
17.3
36.4
536.1
45
37.1
35.1
18.3
15.3
400
17.3
43.0
535.8
45
35.3
33.3
15.8
12.8
500
17.3
45.3
535.6
45
33.8
31.8
13.8
10.8
P
CMP
7.5±0.2
C
CM
7.5±0.2
R
CMR
7.5±0.2
L
LSZH
7.5±0.2
E
LDPE
7.5±0.2
Nominal Transmission Characteristics
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
(dB)
(dB)
( d B/100m)
( d B/100m)
(dB)
( d B/100m)
74.3
72.3
67.8
64.8
67.0
67.0
65.3
63.3
55.8
52.8
67.0
66.2
45
59.3
57.3
47.8
44.8
67.0
60.1
543
45
56.2
54.2
43.7
40.7
67.0
52.2
542.1
45
54.8
52.8
41.8
38.8
67.0
48.3
10.7
540.4
45
51.9
49.9
37.9
34.9
67.0
42.3
15.4
538.6
45
47.4
45.4
31.9
28.9
65.6
38.2
20.1
19.8
537.6
45
44.3
42.3
27.8
24.8
62.5
32.2
200
18.0
29.0
536.1
45
39.8
37.8
21.8
18.8
58.0
30.2
300
17.3
36.4
536.1
45
37.1
35.1
18.3
15.3
55.3
28.7
400
17.3
43.0
535.8
45
35.3
33.3
15.8
12.8
53.5
26.2
500
17.3
45.3
535.6
45
33.8
31.8
13.8
10.8
52.0
24.2
Frequency
DOP(max) Delay Skew NEXT (min)
(max)
RL (min)
IL(max)
(MH)z
(dB)
( d B/100m)
1
20.0
2.1
( n s/100m)
570
( n s/100m)
45
4
23.0
3.8
552
45
10
25.0
6.0
545.4
16
25.0
7.6
20
25.0
8.5
31.25
25.0
62.5
21.5
100
PSANEXT PSAACR-F
(min)
(min)
OPTICAL FIBER
RL (min)
Impedance:1-250MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 8.4(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
Order information(PartNumber)
NTNC6A_ _FTP-_
Nominal Transmission Characteristics
Frequency
Conductor
PATCH PANELS
Impedance:4 - 100MHz 100±15 (ohms) .
100 - 200MHz 100±22 (ohms).
200 - 500MHz 100±32 (ohms).
Max. Conductor DC Resistance 20℃:8.4(ohms/100m).
Resistance unbalance (%):max 2.5.
Pair-to-Ground Capacitance Unbalance 330 (pF/100m).
Transfer Impendance:Max10 mohms/[email protected]
Installation temperature:0~50℃.
Operation temperature:-20~60℃.
Conductor
ElectricalCharacteristics
Total number of
insulated conductors
ElectricalCharacteristics
Jacket
Copper Conductor
HDPE Insulation
Cross Filler
Rip Cord
MODULES
Meets or exceeds requirements of ANSI/TIA-568-C.2
Category 6 and ISO 11801 2nd Edition Class EA channel
standards.
Meets or exceeds requirements of ANSI/TIA-568-C.2 and
IEC 61156-5 Category 6A component standards.
Meets requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications.
Third party tested to comply with ANSI/TIA/EIA-568-C.2.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
Aluminum Foil
PET
Conductor
HDPE Insulation
Cross Filler
Jacket
Drain Wire
Rip Cord
IEC/ISO 61156-5
ANSI/TIA568C.2
ISO/IEC 11801
FACE PLATE
F/UTP Shielded CAT6A Twisted Pair Installation Cable
Standard
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
page 009
CABINETS
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
page 010
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
LAN CABLE
STRUCTURE CABLING
LAN CABLE
U/UTP unshielded CAT6 Twisted PairInstallation Cable
Application
Conductor
ElectricalCharacteristics
Conductor
Solid Bare Copper 23AWG
Insulation
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
Drain wire
Conductor
Order information(PartNumber)
NTNC6E_ _FTP-_
Impedance:1-250MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 8.4(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
None
Overall shield
None
Drain wire
None
Order information(PartNumber)
NTNC6E_ _ - _
Jacket Color
BU
RD
GY
BK
Jacket Color
BU
RD
GY
BK
WH
YL
GN
PR
Item OuterJacket Overalldiameter(mm)
P
CMP
7.6±0.2
WH
YL
C
CM
7.6±0.2
GN
PR
R
CMR
7.6±0.2
L
LSZH
7.6±0.2
E
LDPE
7.6±0.2
Frequency
RL (min)
(MH)z
(dB)
IL(max)
( d B/100m)
DOP(max)
NEXT (min)
( n s/100m)
45
(dB)
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
(dB)
( d B/100m)
( d B/100m)
1
20.0
2
( n s/100m)
570
74
72
67.8
64.8
4
23.0
3.8
552
45
65
63
55.7
52.7
10
25.0
6.0
545
45
59
57
47.8
44.8
16
25.0
7.6
543
45
56
54
43.7
40.7
20
25.
0
8.5
542
45
55
53
41.7
38.7
31.25
23.6
10.7
540
45
52
50
37.9
34.9
62.5
21.5
15.4
538
45
47
45
31.8
28.8
100
20.1
19.8
537
45
44.3
42.3
27.8
24.8
200
18.0
29.0
536
45
39.7
37.7
21.7
18.7
250
17.3
32.8
535
45
38
36
19.8
16.8
P
CMP
6.4±0.2
C
CM
6.4±0.2
R
CMR
6.4±0.2
L
LSZH
6.4±0.2
E
LDPE
6.4±0.2
Nominal Transmission Characteristics
NEXT (min)
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
( n s/100m)
45
(dB)
(dB)
( d B/100m)
( d B/100m)
74
72
67.8
64.8
552
45
65
63
55.7
52.7
6.0
545
45
59
57
47.8
44.8
25.0
7.6
543
45
56
54
43.7
40.7
25.0
8.5
542
45
55
53
41.7
38.7
31.25
23.6
10.7
540
45
52
50
37.9
34.9
62.5
21.5
15.4
538
45
47
45
31.8
28.8
100
20.1
19.8
537
45
44.3
42.3
27.8
24.8
200
18.0
29.0
536
45
39.7
37.7
21.7
18.7
250
17.3
32.8
535
45
38
36
19.8
16.8
RL (min)
IL(max)
DOP(max)
Delay Skew
(max)
(MH)z
(dB)
( d B/100m)
1
20.0
2
( n s/100m)
570
4
23.0
3.8
10
25.0
16
20
Frequency
Delay Skew
(max)
Item OuterJacket Overalldiameter(mm)
OPTICAL FIBER
Nominal Transmission Characteristics
Solid Bare Copper 23AWG
Insulation
ElectricalCharacteristics
None
Aluminum foil, providing 100%
coverage, foil face out.
Tinned copper
Overall shield
Conductor
PATCH PANELS
Impedance:1-250MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 8.4(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
Conductor
HDPE Insulation
Cross Filler
Jacket
Rip Cord
Meets or exceeds requirements of ANSI/TIA-568-C.2
Category 6 and ISO 11801 2nd Edition Class E channel
standards.
Meets or exceeds requirements of ANSI/TIA-568-C.2 and
IEC 61156-5 Category 6 component standards.
Meets requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications.
Third party tested to comply with ANSI/TIA/EIA-568-C.2.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
MODULES
Aluminum Foil
PET
Conductor
HDPE Insulation
Cross Filler
Jacket
Drain Wire
Rip Cord
Exceeds ANSI/TIA-568-C.2 and ISO 11801 2nd Edition
Class E Category 6 channel standards.
Exceeds requirements of ANSI/TIA-568-C.2 and IEC
61156-5 Category 6 component standards.
Meets IEEE 802.3af and IEEE 802.3at for PoE applications.
Foil shield reduces ingress of EMI interference to ensure
cable performance at high frequency levels.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
FACE PLATE
F/UTP shielded CAT6 Twisted Pair Installation Cable
Application
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
page 011
CABINETS
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
page 012
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
LAN CABLE
STRUCTURE CABLING
LAN CABLE
SF/UTP double fully shielded CAT6 Twisted Pair
Installation Cable
Application
Conductor
ElectricalCharacteristics
Conductor
Solid Bare Copper 23AWG
Insulation
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
Drain wire
Conductor
Conductor
ElectricalCharacteristics
None
Aluminum foil, providing 100%
coverage, foil face out.
Tinned copper
Overall shield
Exceeds ANSI/TIA-568-C.2 and ISO 11801 2nd Edition
Class E Category 6 channel standards.
Exceeds requirements of ANSI/TIA-568-C.2 and IEC
61156-5 Category 6 component standards.
Meets IEEE 802.3af and IEEE 802.3at for PoE applications.
Foil shield reduces ingress of EMI interference to ensure
cable performance at high frequency levels.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
Order information(PartNumber)
NTNC6E_ _FTP-_
RD
GY
BK
WH
YL
GN
PR
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
None
Aluminum foil, providing 100%
coverage, foil face out.
None
Drain wire
Order information(PartNumber)
NTNC6E_ _STP-_
Jacket Color
RD
GY
BK
7.6±0.2
WH
YL
LSZH
7.6±0.2
GN
PR
LDPE
7.6±0.2
CMP
7.6±0.2
C
CM
7.6±0.2
R
CMR
L
E
Item OuterJacket Overalldiameter(mm)
P
CMP
8.1±0.2
C
CM
8.1±0.2
R
CMR
8.1±0.2
L
LSZH
8.1±0.2
E
LDPE
8.1±0.2
OPTICAL FIBER
BU
P
Nominal Transmission Characteristics
NEXT (min)
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
Frequency
RL (min)
IL(max)
DOP(max)
Delay Skew
(max)
( n s/100m)
45
(dB)
(dB)
( d B/100m)
( d B/100m)
(MH)z
(dB)
( d B/100m)
74
72
67.8
64.8
1
20
2.2
( n s/100m)
590
( n s/100m)
62
552
45
65
63
55.7
52.7
4
23
4.1
572
62
6.0
545
45
59
57
47.8
44.8
10
25
6.5
565
62
25.0
7.6
543
45
56
54
43.7
40.7
16
25
8.2
563
62
25.
0
8.5
542
45
55
53
41.7
38.7
20
25
9.3
562
62
31.25
23.6
10.7
540
45
52
50
37.9
34.9
31.25
23.6
11.5
560
62
62.5
21.5
15.4
538
45
47
45
31.8
28.8
62.5
21.5
16.2
558
100
20.1
19.8
537
45
44.3
42.3
27.8
24.8
100
20.1
20.4
557
200
18.0
29.0
536
45
39.7
37.7
21.7
18.7
200
18
29.2
250
17.3
32.8
535
45
38
36
19.8
16.8
250
17.3
33.8
RL (min)
IL(max)
DOP(max)
Delay Skew
(max)
(MH)z
(dB)
( d B/100m)
1
20.0
2
( n s/100m)
570
4
23.0
3.8
10
25.0
16
20
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
(dB)
(dB)
( d B/100m)
( d B/100m)
74.3
72.3
67.8
64.8
65.2
63.2
55.7
52.7
59.3
57.3
47.8
44.8
56.2
54.2
43.7
40.7
54.7
52.7
41.7
38.7
51.8
49.8
37.9
34.9
62
47.3
45.3
31.8
28.8
62
44.3
42.3
27.8
24.8
556
62
39.7
37.7
21.7
18.7
555
62
38.3
36.3
19.8
16.8
NEXT (min)
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
CABINETS
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
page 013
8, twisted in 4 pairs
Overall shield
Item OuterJacket Overalldiameter(mm)
Nominal Transmission Characteristics
Frequency
HDPE
Total number of
insulated conductors
Individual pair shield
Impedance:1-250MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 8.4(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
Jacket Color
BU
Solid Bare Copper 23AWG
Insulation
PATCH PANELS
Impedance:1-250MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 8.4(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
Braid
PET
Copper Conductor
HDPE Insulation
Cross Filler
Jacket
Aluminum Foil
Rip Cord
MODULES
Aluminum Foil
PET
Conductor
HDPE Insulation
Cross Filler
Jacket
Drain Wire
Rip Cord
Exceeds ANSI/TIA-568-C.2 and ISO 11801 2nd Edition
Class E Category 6 channel standards.
Exceeds requirements of ANSI/TIA-568-C.2 and IEC
61156-5 Category 6 component standards.
Meets IEEE 802.3af and IEEE 802.3at for PoE applications.
Foil shield reduces ingress of EMI interference to ensure
cable performance at high frequency levels.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
FACE PLATE
F/UTP shielded CAT6 Twisted Pair Installation Cable
Application
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
page 014
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
LAN CABLE
STRUCTURE CABLING
LAN CABLE
F/UTP shielded CAT5e Twisted Pair Installation Cable
Solid Bare Copper 24AWG
Insulation
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
None
Overall shield
None
Drain wire
None
Impedance:1-100MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 9.5(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
Jacket Color
BU
RD
BK
WH
YL
GN
PR
5.1±0.2
L
LSZH
5.1±0.2
WH
YL
E
LDPE
5.1±0.2
GN
PR
16
25.0
20
25.0
31.25
23.6
62.5
21.5
100
20.1
BU
RD
GY
BK
( d B/100m)
65
62
61
61
552
45
56
53
48
48
545
45
50
47
41
41
543
45
47
44
36
542
45
45
42
34
61
552
45
56
53
48
48
545
45
50
47
41
41
543
45
47
44
36
36
34
36
10
25.0
34
16
25.0
.
6. 5
8. 4
9. 3
11 . 6
17 . 0
22 . 0
31
31
20
25.0
25
31.25
23.6
537
45
35
32
21
21
62.5
21.5
100
20.1
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
( d B/100m)
61
23.0
25
6.3±0.2
( d B/100m)
4
39
LDPE
62
( n s/100m)
570
35
6.3±0.2
E
(dB)
2.2
42
LSZH
65
( d B/100m)
20.0
38
6.3±0.2
L
(dB)
(dB)
1
45
CMR
( n s/100m)
45
(MH)z
45
6.3±0.2
R
PSACR-F
(min)
Delay Skew
(max)
540
6.3±0.2
CM
ACR-F
(min)
DOP(max)
538
CMP
PSNEXT
(min)
IL(max)
4 2
P
C
NEXT (min)
RL (min)
Frequency
Item OuterJacket Overalldiameter(mm)
542
45
45
42
34
540
45
42
39
31
31
538
45
38
35
25
25
537
45
35
32
21
21
OPTICAL FIBER
25.0
Jacket Color
CMR
( d B/100m)
( n s/100m)
570
10
Order information(PartNumber)
NTNC5E_ _FTP-_
R
(dB)
( d B/100m)
Aluminum foil, providing 100%
coverage, foil face out.
None
Drain wire
5.1±0.2
(dB)
(dB)
.
6. 5
8. 4
9. 3
11 . 6
17 . 0
22 . 0
None
CM
( n s/100m)
45
(MH)z
2.2
Individual pair shield
C
PSACR-F
(min)
Delay Skew
(max)
4 2
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
5.1±0.2
ACR-F
(min)
DOP(max)
23.0
Color code
CMP
PSNEXT
(min)
IL(max)
20.0
8, twisted in 4 pairs
P
NEXT (min)
RL (min)
1
HDPE
Total number of
insulated conductors
Nominal Transmission Characteristics
Frequency
Solid Bare Copper 24AWG
Insulation
Overall shield
Item OuterJacket Overalldiameter(mm)
Nominal Transmission Characteristics
4
Conductor
ElectricalCharacteristics
Order information(PartNumber)
NTNC5E_ _ - _
GY
Conductor
PATCH PANELS
Impedance:1-100MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 9.5(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
Conductor
Exceeds ANSI/TIA-568-C.2 and ISO 11801 2nd Edition
Class D Category 5e channel standards.
Exceeds requirements of ANSI/TIA-568-C.2 and IEC
61156-5 Category 5e component standards.
Meets requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications.
Foil shield reduces ingress of EMI interference to ensure
cable performance at high frequency levels.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
MODULES
Conductor
ElectricalCharacteristics
PET
Copper Conductor
HDPE Insulation
Aluminum Foil
Jacket
Drain Wire
Rip Cord
Application
Copper Conductor
HDPE Insulation
Pair
Jacket
Rip Cord
Meets or exceeds requirements of ANSI/TIA-568-C.2
Category 5e and ISO 11801 2nd Edition Class D channel
standards.
Meets or exceeds requirements of ANSI/TIA-568-C.2
and IEC 61156-5 Category 5e component standards.
Third party tested to Category 5e channel compliance.
Meets requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
FACE PLATE
U/UTP unshielded CAT5e Twisted Pair Installation Cable
Application
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
CABINETS
page 015
page 016
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
LAN CABLE
STRUCTURE CABLING
LAN CABLE
U/UTP unshielded CAT6 Twisted Pair Installation Cable
Braid
PET
Copper Conductor
HDPE Insulation
Pair
Jacket
Aluminum Foil
Rip Cord
Application
Conductor
ElectricalCharacteristics
Solid Bare Copper 24AWG
Insulation
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
None
Drain wire
Conductor
Conductor
Order information(PartNumber)
NTNC5E_ _STP-_
Impedance:1-250MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 8.4(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
Solid Bare Copper 23AWG
Insulation
HDPE
Total number of
insulated conductors
2x8, twisted in 2x 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
None
Overall shield
None
Drain wire
None
ElectricalCharacteristics
Aluminum foil, providing 100%
coverage, foil face out.
None
Overall shield
Conductor
HDPE Insulation
Cross Filler
Jacket
Rip Cord
PATCH PANELS
Impedance:1-100MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 9.5(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
Conductor
Meets or exceeds requirements of ANSI/TIA-568-C.2
Category 6 and ISO 11801 2nd Edition Class E channel
standards.
Meets or exceeds requirements of ANSI/TIA-568-C.2 and
IEC 61156-5 Category 6 component standards.
Meets requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications.
Third party tested to comply with ANSI/TIA/EIA-568-C.2.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
MODULES
Exceeds ANSI/TIA-568-C.2 and ISO 11801 2nd Edition
Class D Category 5e channel standards.
Exceeds requirements of ANSI/TIA-568-C.2 and IEC
61156-5 Category 5e component standards.
Meets requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications.
Foil shield reduces ingress of EMI interference to ensure
cable performance at high frequency levels.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
FACE PLATE
SF/UTP double fully shielded CAT5e Twisted Pair
Installation Cable
Application
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Order information(PartNumber)
NTNC6E_ _2 -_
Jacket Color
BU
RD
GY
BK
WH
YL
GN
PR
RL (min)
IL(max)
DOP(max)
Delay Skew
(max)
(MH)z
(dB)
( d B/100m)
1
20.0
2.2
( n s/100m)
570
( n s/100m)
45
.
.
8. 4
9. 3
11 . 6
17 . 0
22 . 0
4
23.0
25.0
16
25.0
20
25.0
31.25
23.6
62.5
21.5
100
20.1
CMP
6.5±0.2
CM
6.5±0.2
R
CMR
6.5±0.2
L
LSZH
6.5±0.2
E
LDPE
6.5±0.2
BU
RD
GY
BK
WH
YL
GN
PR
Nominal Transmission Characteristics
Frequency
10
P
C
NEXT (min)
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
(dB)
(dB)
( d B/100m)
( d B/100m)
65
62
61
61
P
CMP
(6.6+6.6)+/-0.2
C
CM
(6.6+6.6)+/-0.2
R
CMR
(6.6+6.6)+/-0.2
L
LSZH
(6.6+6.6)+/-0.2
E
LDPE
(6.6+6.6)+/-0.2
NEXT (min)
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
( n s/100m)
45
(dB)
(dB)
( d B/100m)
( d B/100m)
74
72
67.8
64.8
RL (min)
IL(max)
DOP(max)
Delay Skew
(max)
(MH)z
(dB)
( d B/100m)
20.0
2
( n s/100m)
570
Frequency
Item OuterJacket Overalldiameter(mm)
4 2
552
45
56
53
48
48
1
6 5
545
45
50
47
41
41
4
23.0
3.8
552
45
65
63
55.7
52.7
543
45
47
44
36
36
10
25.0
6.0
545
45
59
57
47.8
44.8
40.7
542
45
45
42
34
34
16
25.0
7.6
543
45
56
54
43.7
540
45
42
39
31
31
20
25.
0
8.5
542
45
55
53
41.7
38.7
538
45
38
35
25
25
31.25
23.6
10.7
540
45
52
50
37.9
34.9
537
45
35
32
21
21
62.5
21.5
15.4
538
45
47
45
31.8
28.8
100
20.1
19.8
537
45
44.3
42.3
27.8
24.8
200
18.0
29.0
536
45
39.7
37.7
21.7
18.7
250
17.3
32.8
535
45
38
36
19.8
16.8
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
OPTICAL FIBER
Nominal Transmission Characteristics
Jacket Color
Item OuterJacket Overalldiameter(mm)
CABINETS
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
page 017
page 018
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
LAN CABLE
STRUCTURE CABLING
LAN CABLE
Application
Application
Copper Conductor
HDPE Insulation
Pair
Jacket
Rip Cord
Conductor
Conductor
Solid Bare Copper 24AWG
Insulation
HDPE
2x8, twisted in 2x4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
None
ElectricalCharacteristics
None
Order information(PartNumber)
NTNC5E_ _2 -_
Jacket Color
BU
RD
GY
BK
WH
YL
GN
PR
Item OuterJacket Overalldiameter(mm)
CMP
(5.2+5.2)+/-0.3
CM
(5.2+5.2)+/-0.3
R
CMR
(5.2+5.2)+/-0.3
L
LSZH
(5.2+5.2)+/-0.3
E
LDPE
(5.2+5.2)+/-0.3
NEXT (min)
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
25.0
25.0
4 2
.
.
8. 4
9. 3
11 . 6
17 . 0
22 . 0
552
45
56
53
48
48
20
25.0
6 5
545
45
50
47
41
41
31.25
23.6
543
45
47
44
36
36
62.5
21.5
100
20.1
62.5
21.5
100
20.1
538
45
38
35
25
25
537
45
35
32
21
21
45
56
53
48
48
545
45
50
47
41
41
543
45
47
44
36
36
34
.
6. 5
8. 4
9. 3
11 . 6
17 . 0
22 . 0
10
31
61
552
23.0
16
34
( d B/100m)
61
4
61
31
( d B/100m)
62
( n s/100m)
570
( d B/100m)
34
(dB)
65
2.2
61
42
(dB)
( d B/100m)
( d B/100m)
39
( n s/100m)
45
(dB)
62
42
PSACR-F
(min)
20.0
(dB)
45
ACR-F
(min)
1
65
45
PSNEXT
(min)
(MH)z
(dB)
45
NEXT (min)
Delay Skew
(max)
( n s/100m)
45
542
(5.1+2.3)±0.3
DOP(max)
( n s/100m)
570
540
Overalldiameter(mm)
LDPE
IL(max)
2.2
25.0
OuterJacket
RL (min)
Frequency
( d B/100m)
23.6
Item
NTNC5EBKSTW-E
Nominal Transmission Characteristics
(dB)
20
Order information(PartNumber)
4 2
542
45
45
42
34
540
45
42
39
31
31
538
45
38
35
25
25
537
45
35
32
21
21
OPTICAL FIBER
P
C
Impedance:1-100MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 9.5(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
20.0
31.25
None
None
1
25.0
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Drain wire
ElectricalCharacteristics
(MH)z
16
Color code
Overall shield
DOP(max)
25.0
8, twisted in 4 pairs
None
IL(max)
23.0
HDPE
Total number of
insulated conductors
None
RL (min)
4
Solid Bare Copper 24AWG
Insulation
Drain wire
Delay Skew
(max)
10
Conductor
Overall shield
Nominal Transmission Characteristics
Frequency
Conductor
Individual pair shield
Impedance:1-100MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 9.5(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
Copper Conductor
HDPE Insulation
Pair
Jacket
Rip Cord
Meets or exceeds requirements of ANSI/TIA-568-C.2
Category 5e and ISO 11801 2nd Edition Class D channel
standards.
.
Meets or exceeds requirements of ANSI/TIA-568-C.2 and
IEC 61156-5 Category 5e component standards.
.
Third party tested to Category 5e channel compliance.
.
Meets requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications.
.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
.
Color Availability: Additional cable colors available.
.
PATCH PANELS
Total number of
insulated conductors
MODULES
U/UTP steel wire support unshielded CAT5e Twisted
Pair Installation Cable
FACE PLATE
U/UTP unshielded CAT5e Twisted Pair Installation Cable
Meets or exceeds requirements of ANSI/TIA-568-C.2
Category 5e and ISO 11801 2nd Edition Class D channel
standards.
Meets or exceeds requirements of ANSI/TIA-568-C.2
and IEC 61156-5 Category 5e component standards.
Third party tested to Category 5e channel compliance.
Meets requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
Patent products:CN200920124768.4.
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
CABINETS
page 019
page 020
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
LAN CABLE
STRUCTURE CABLING
LAN CABLE
U/UTP unshielded CAT5e Twisted 8 Pair
Installation Cable
Application
Conductor
Solid Bare Copper 24AWG
Insulation
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
None
Aluminum foil, providing 100%
coverage, foil face out.
None
Overall shield
Impedance:1-100MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 9.5(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
Drain wire
Order information
Item
OuterJacket
Overalldiameter(mm)
NTNC5EBKFTPSW-P
CMP
(6.3+2.3)±0.3
NTNC5EBKFTPSW-C
CM
(6.3+2.3)±0.3
25.0
31.25
23.6
62.5
21.5
100
20.1
Order information(PartNumber)
NTNC5E_ _8PR -_
Jacket Color
BU
RD
BK
GN
PR
Item OuterJacket Overalldiameter(mm)
P
CMP
8.1±0.2
C
CM
8.1±0.2
R
CMR
8.1±0.2
L
LSZH
8.1±0.2
E
LDPE
8.1±0.2
OPTICAL FIBER
25.0
None
Impedance:1-100MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 9.5(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
YL
Nominal Transmission Characteristics
NEXT (min)
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
( n s/100m)
45
(dB)
(dB)
( d B/100m)
( d B/100m)
65
62
61
61
552
45
56
53
48
48
545
45
50
47
41
41
543
45
47
44
36
542
45
45
42
34
( n s/100m)
570
20
None
Drain wire
ElectricalCharacteristics
WH
( d B/100m)
16
None
Overall shield
(6.3+2.3)±0.3
(dB)
25.0
Individual pair shield
(6.3+2.3)±0.3
(MH)z
10
White/Blue,White/Orange,White/Green,
White/Brown,White/Grey
Red/Blue,Red/Orange,Red/Green
LSZH
Delay Skew
(max)
.
6. 5
8. 4
9. 3
11 . 6
17 . 0
22 . 0
Color code
LDPE
DOP(max)
2.2
16, twisted in 8 pairs
NTNC5EBKFTPSW-L
IL(max)
4 2
HDPE
Total number of
insulated conductors
NTNC5EBKFTPSW-E
RL (min)
23.0
Solid Bare Copper 24AWG
Insulation
(6.3+2.3)±0.3
Frequency
20.0
Conductor
CMR
Nominal Transmission Characteristics
1
Conductor
GY
NTNC5EBKFTPSW-R
4
HDPE Insulation
Filler
Rip Cord
Jacket
Meets or exceeds requirements of ANSI/TIA-568-C.2
Category 5e and ISO 11801 2nd Edition Class D channel
standards.
Meets or exceeds requirements of ANSI/TIA-568-C.2
and IEC 61156-5 Category 5e component standards.
Third party tested to Category 5e channel compliance.
Meets requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
Patent products:CN201020293718.1.
PATCH PANELS
ElectricalCharacteristics
Conductor
Copper Conductor
MODULES
PET
Copper Conductor
HDPE Insulation
Aluminum Foil
Jacket
Drain Wire
Rip Cord
Exceeds ANSI/TIA-568-C.2 and ISO 11801 2nd Edition
Class D Category 5e channel standards.
Exceeds requirements of ANSI/TIA-568-C.2 and IEC
61156-5 Category 5e component standards.
Meets requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications.
Foil shield reduces ingress of EMI interference to ensure
cable performance at high frequency levels.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
FACE PLATE
F/UTP steel wire support shielded CAT5e Twisted Pair
Installation Cable
Application
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
PSNEXT
(min)
ACR-F
(min)
PSACR-F
(min)
( n s/100m)
45
(dB)
(dB)
( d B/100m)
( d B/100m)
65
62
61
61
552
45
56
53
48
48
545
45
50
47
41
41
543
45
47
44
36
36
34
IL(max)
DOP(max)
Delay Skew
(max)
(MH)z
(dB)
( d B/100m)
1
20.0
2.2
( n s/100m)
570
4
23.0
36
10
25.0
34
16
25.0
.
6. 5
8. 4
9. 3
11 . 6
17 . 0
22 . 0
540
45
42
39
31
31
20
25.0
538
45
38
35
25
25
31.25
23.6
537
45
35
32
21
21
62.5
21.5
100
20.1
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
NEXT (min)
RL (min)
Frequency
4 2
542
45
45
42
34
540
45
42
39
31
31
538
45
38
35
25
25
537
45
35
32
21
21
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
CABINETS
page 021
page 022
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
LAN CABLE
STRUCTURE CABLING
LAN
CABLE
U/UTP unshielded CAT5e Twisted 25 Pair
Installation Cable
ElectricalCharacteristics
ElectricalCharacteristics
.
Patent products:CN200920124769 9.
MechanicalCharacteristics
MechanicalCharacteristics
Order information(PartNumber)
NTNC3 _ _ _ _ _ PR- _
Jacket Color
BU
RD
GY
BK
WH
YL
GN
PR
025 25 Pairs
050 50 Pairs
100 100 Pairs
Item OuterJacket Overalldiameter(mm)
P
CMP
12.5±1.0
L
LSZH
12.5±1.0
E
LDPE
12.5±1.0
U/UTP unshielded CAT5 Twisted 25/50/100 Pair
Installation Cable
Application
Impedance:1-100MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 111(Ohms).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
BK
WH
YL
GN
PR
Jacket Color
BU
RD
GY
BK
WH
YL
GN
PR
P
CMP
12.5±1.0
L
LSZH
12.5±1.0
E
LDPE
12.5±1.0
ElectricalCharacteristics
Impedance:1-16MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 111(Ohms).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
Copper Conductor
HDPE Insulation
Pair
Jacket
Rip Cord
Conductor
Conductor
Item OuterJacket Overalldiameter(mm)
P
CMP
12.5±1.0
L
LSZH
12.5±1.0
E
LDPE
12.5±1.0
Cable under the minimum tension≥400N.
Conductor elongation:≥15%.
Jacket before Aging
Tensile Strength≥13.5Mpa
Elongation ≥150%.
Jacket After Aging
Tensile Strength ≥12.5Mpa
Elongation ≥125%.
Solid Bare Copper 24AWG
Insulation
HDPE
Total number of
insulated conductors
4, twisted in 2 pairs
Color code
White-Blue/Blue,White-Orange/Orange
Individual pair shield
None
Overall shield
None
Drain wire
None
Order information(PartNumber)
Item
OuterJacket
Overalldiameter(mm)
NTNC3_ _2PR-P
CMP
4.3±0.2
Jacket Color
BU
page 023
Item OuterJacket Overalldiameter(mm)
CABINETS
GY
025 25 Pairs
050 50 Pairs
100 100 Pairs
Order information(PartNumber)
NTNC5E_ _25PR -_
MechanicalCharacteristics
Jacket Color
RD
Meets or exceeds requirements of ANSI/TIA-568-C.2
Category 5e and ISO 11801 2nd Edition Class D channel
standards.
Meets or exceeds requirements of ANSI/TIA-568-C.2
and IEC 61156-5 Category 5e component standards.
Third party tested to Category 5e channel compliance.
Meets requirements of IEEE 802.3af and IEEE 802.3at for
PoE applications.
Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
Patent products:CN201020093721.3.
U/UTP unshielded CAT3 Twisted 2 Pair Installation Cable
Order information(PartNumber)
NTNC5 _ _ _ _ _ PR- _
BU
Application
OPTICAL FIBER
Cable under the minimum tension≥400N.
Conductor elongation:≥15%.
Jacket before Aging
Tensile Strength≥13.5Mpa
Elongation ≥150%.
Jacket After Aging
Tensile Strength ≥12.5Mpa
Elongation ≥125%.
Cable under the minimum tension≥400N.
Conductor elongation:≥15%.
Jacket before Aging
Tensile Strength≥13.5Mpa
Elongation ≥150%.
Jacket After Aging
Tensile Strength ≥12.5Mpa
Elongation ≥125%.
ElectricalCharacteristics
Exceeds requirements and ISO 11801 Class D channel
standards.
Exceeds the requirements and IEC 61156-5 Category 5
component standards.
Descending cable length markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Packaged 305m (1,000 ft.) on a reel.
Color Availability: Additional cable colors available.
Patent products:CN200920124769.9.
MechanicalCharacteristics
Impedance:1-100MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 111(Ohms).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
HDPE Insulation
Filler
PET
Jacket
Rip Cord
PATCH PANELS
Cable under the minimum tension≥400N.
Conductor elongation:≥15%.
Jacket before Aging
Tensile Strength≥13.5Mpa
Elongation ≥150%.
Jacket After Aging
Tensile Strength ≥12.5Mpa
Elongation ≥125%.
Impedance:1-16MHz 100±15(Ohms).
Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5.
DC Resistance 20℃: 111(Ohms).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km.
Dielectric strength: DC 2500V 2S.
Copper Conductor
MODULES
Exceeds requirements of ANSI/TIA-568-C.2 Category 3 and
ISO 11801 Class C channel standards.
Exceeds the requirements of ANSI/TIA-568-C.2 Category
3 component standards.
Descending cable length markings enable easy identification
of remaining cable which reduces installation time and cable
scrap.
Color Availability: Additional cable colors available.
FACE PLATE
U/UTP unshielded CAT3 Twisted 25/50/100 Pair
Installation Cable
Application
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
RD
GY
BK
WH
YL
GN
PR
page 024
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
PATCH CORD
STRUCTURE CABLING
PATCH CORD
U/UTP unshielded twisted 4 pairs category 6A
patch cord
Conductor
Al-mylar Foil
Standard
Standard
Electrical performance guaranteed to meet or exceed
ANSI/TIA-568B Category 6A and ISO/EIC specifications.
Independently tested and verified intertek (ETL).
Ideal for Data center architectural requirements.
Stranded cable for maximum flexibility.
Available with different plug mold.
Available with different color of cable.
Available with different length.
PATCH PANELS
Electrical performance guaranteed to meet or exceed
ANSI/TIA-568B Category 6 and ISO/EIC specifications.
Independently tested and verified intertek (ETL).
Ideal for Data center architectural requirements.
Stranded cable for maximum flexibility.
Available with different plug mold.
Available with different color of cable.
Available with different length.
Conductor
Conductor
Conductor
Standed bare copper 26AWG
Insulation
PE(Foam-Skin)
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
blue x white, orange x white,
green x white, brown x white
Individual pair shield
aluminum foil, providing 100%
coverage, foil face out
Overall shield
Tinned copper braid
Drain wire
None
Conductor
Orderinformation(PartNumber)
NTPC6A_ _ _ _ SFTP
Available Length
Delay
Skew
Ω
Max.
ns
ns
i
100m
550
50
02
03
05
07
10
15
25
50
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
None
Overall shield
BU
RD
WH
YL
None
Drain wire
None
GY
BK
GN
OR
PS
PS NEXT ACR-N
PS
ACR-F
Orderinformation(PartNumber)
NTPC6A_ _ _ _ SFTP
Available Length
Prop.
Delay
Delay
Skew
Insertion
Loss
NEXT
RL
ACR-N
ACR-F
1
3
65.0
19.0
62.0
63.3
62.0
59.0
60.3
Insertion
Loss
05
07
10
15
25
50
Jacket Color
BU
RD
WH
YL
GY
BK
GN
OR
1
3
65.0
4
4.2
63.0
19.0
58.9
51.2
60.5
56.4
48.2
4
4.2
63.0
8
5.8
58.2
19.0
52.4
45.2
55.6
49.8
42.2
8
5.8
58.2
10
6.5
56.6
19.0
50.1
43.3
54.0
47.5
40.3
10
6.5
16
8.2
53.2
18.0
45.0
39.2
50.6
42.4
36.2
16
20
9.2
51.6
17.5
42.5
37.2
49.0
39.8
34.2
25
10.2
50.0
17.0
39.8
35.3
47.3
37.1
31.25
11.5
48.4
16.5
36.9
33.4
45.7
62.5
16.4
43.4
14.0
27.0
27.3
100
20.9
39.9
12.0
19.0
200
30.1
34.8
9.0
250
33.9
33.1
350
40.6
500
49.3
NEXT
PS
ACR-F
ACR-F
19.0
62.0
63.3
62.0
59.0
60.3
19.0
58.9
51.2
60.5
56.4
48.2
19.0
52.4
45.2
55.6
49.8
42.2
56.6
19.0
50.1
43.3
54.0
47.5
40.3
8.2
53.2
18.0
45.0
39.2
50.6
42.4
36.2
20
9.2
51.6
17.5
42.5
37.2
49.0
39.8
34.2
32.3
25
10.2
50.0
17.0
39.8
35.3
47.3
37.1
32.3
34.2
30.4
31.25
11.5
48.4
16.5
36.9
33.4
45.7
34.2
30.4
40.6
24.2
24.3
62.5
16.4
43.4
14.0
27.0
27.3
40.6
24.2
24.3
23.3
37.1
16.2
20.3
100
20.9
39.9
12.0
19.0
23.3
37.1
16.2
20.3
4.7
17.2
31.9
1.8
14.2
200
30.1
34.8
9.0
4.7
17.2
31.9
1.8
14.2
8.0
-0.8
15.3
30.2
-3.7
12.3
250
33.9
33.1
8.0
-0.8
15.3
30.2
-3.7
12.3
30.3
6.6
-10.3
12.4
27.3
-13.3
9.4
350
40.6
30.3
6.6
-10.3
12.4
27.3
-13.3
9.4
26.1
6.0
-23.2
9.3
23.2
-26.1
6.3
500
49.3
26.1
6.0
-23.2
9.3
23.2
-26.1
6.3
Max.
ns
ns
i
100m
550
50
RL
PS
PS NEXT ACR-N
ACR-N
Ω
Freq.
03
CABINETS
Freq.
Length
02
Special orders available upon request.
Nominal Transmission Characteristics
Res.
01
OPTICAL FIBER
Prop.
Delay
01
Stranded Bare Copper 24AWG
Insulation
Jacket Color
Special orders available upon request.
Nominal Transmission Characteristics
page 025
MODULES
Conductor
HDPE Insulation
Cross Filler
Jacket
Braid
Insulation(skin-foam-skin)
Jacket
Length
FACE PLATE
S/FTP double fully shielded twisted 4 pairs category 6A
patch cord
Res.
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
page 026
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
PATCH CORD
STRUCTURE CABLING
PATCH CORD
F/FTP shielded twisted 4 pairs category 6
patch cord
MODULES
Aluminum Foil
PET
Conductor
HDPE Insulation
Cross Filler
Jacket
Drain Wire
Conductor
HDPE Insulation
Cross Filler
Jacket
Standard
Standard
Conductor
Conductor
Conductor
Conductor
Stranded Bare Copper 24AWG
Insulation
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
None
Orderinformation(PartNumber)
NTPC6A_ _ _ _ SFTP
Available Length
01
02
03
None
05
07
10
Drain wire
None
15
25
50
Prop.
Delay
Delay
Skew
Ω
Max.
ns
ns
i
100m
555
50
stranded bare copper 26AWG
Insulation
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
Jacket Color
BU
RD
WH
YL
GY
BK
GN
OR
Special orders available upon request.
PS
PS NEXT ACR-N
PS
ACR-F
Orderinformation(PartNumber)
NTPC6A_ _ _ _ SFTP
None
Available Length
Aluminum foil, providing 100%
coverage, foil face out.
Tinned copper
Overall shield
Drain wire
Prop.
Delay
Delay
Skew
Insertion
Loss
NEXT
RL
ACR-N
ACR-F
1
3
65.0
19.0
62.0
63.3
62.0
59.0
60.3
Insertion
Loss
05
07
10
15
25
50
Jacket Color
BU
RD
WH
YL
GY
BK
GN
OR
1
3
65.0
4
4
63.0
19.0
59.0
51.2
60.5
56.5
48.2
4
4
63.0
8
5.7
58.2
19.0
52.5
45.2
55.6
49.9
42.2
8
5.7
58.2
10
6.3
56.6
19.0
50.2
43.3
54.0
47.7
40.3
10
6.3
16
8
53.2
18.0
45.2
39.2
50.6
42.6
36.2
16
20
9
51.6
17.5
42.6
37.2
49.0
39.9
34.2
25
10.1
50.0
17.0
39.9
35.3
47.3
37.2
31.25
11.4
48.4
16.5
37.0
33.4
45.7
62.5
16.5
43.4
14.0
26.9
27.3
100
21.3
39.9
12.0
18.6
200
31.5
34.8
9.0
250
35.9
33.1
8.0
NEXT
PS
ACR-F
ACR-F
19.0
62.0
63.3
62.0
59.0
60.3
19.0
59.0
51.2
60.5
56.5
48.2
19.0
52.5
45.2
55.6
49.9
42.2
56.6
19.0
50.2
43.3
54.0
47.7
40.3
8
53.2
18.0
45.2
39.2
50.6
42.6
36.2
20
9
51.6
17.5
42.6
37.2
49.0
39.9
34.2
32.3
25
10.1
50.0
17.0
39.9
35.3
47.3
37.2
32.3
34.3
30.4
31.25
11.4
48.4
16.5
37.0
33.4
45.7
34.3
30.4
40.6
24.1
24.3
62.5
16.5
43.4
14.0
26.9
27.3
40.6
24.1
24.3
23.3
37.1
15.8
20.3
100
21.3
39.9
12.0
18.6
23.3
37.1
15.8
20.3
3.3
17.2
31.9
0.3
14.2
200
31.5
34.8
9.0
3.3
17.2
31.9
0.3
14.2
-2.8
15.3
30.2
-5.8
12.3
250
35.9
33.1
8.0
-2.8
15.3
30.2
-5.8
12.3
Max.
ns
ns
i
100m
555
50
RL
PS
PS NEXT ACR-N
ACR-N
Ω
Freq.
03
CABINETS
Freq.
Length
02
Special orders available upon request.
Nominal Transmission Characteristics
Res.
01
OPTICAL FIBER
Overall shield
Nominal Transmission Characteristics
page 027
PATCH PANELS
Electrical performance guaranteed to meet or exceed
ANSI/TIA-568B Category 6 and ISO/EIC specifications.
Independently tested and verified intertek (ETL).
Ideal for Data center architectural requirements.
Stranded cable for maximum flexibility.
Available with different plug mold.
Available with different color of cable.
Available with different length.
Electrical performance guaranteed to meet or exceed
ANSI/TIA-568B Category 6 and ISO/EIC specifications.
Independently tested and verified intertek (ETL).
Ideal for Data center architectural requirements.
Stranded cable for maximum flexibility.
Available with different plug mold.
Available with different color of cable.
Available with different length.
Length
FACE PLATE
U/UTP unshielded twisted 4 pairs category 6
patch cord
Res.
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
page 028
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
PATCH CORD
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
PATCH CORD
Copper Conductor
HDPE Insulation
Pair
Jacket
PET
Copper Conductor
HDPE Insulation
Aluminum Foil
Jacket
Drain Wire
Standard
Standard
Electrical performance guaranteed to meet or exceed
ANSI/TIA-568B Category 5e and ISO/EIC specifications.
Independently tested and verified intertek (ETL).
Ideal for Data center architectural requirements.
Stranded cable for maximum flexibility.
Available with different plug mold.
Available with different color of cable.
Available with different length.
Conductor
PATCH PANELS
Electrical performance guaranteed to meet or exceed
ANSI/TIA-568B Category 5e and ISO/EIC specifications.
Independently tested and verified intertek (ETL).
Ideal for Data center architectural requirements.
Stranded cable for maximum flexibility.
Available with different plug mold.
Available with different color of cable.
Available with different length.
MODULES
F/UTP shielded twisted 4 pairs category 5e
patch cord
FACE PLATE
U/UTP unshielded twisted 4 pairs category 5e
patch cord
Conductor
Conductor
stranded bare copper 24AWG
Insulation
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
None
01
02
03
Overall shield
None
05
07
10
Available Length
None
15
25
50
Conductor
RD
WH
YL
GY
BK
GN
OR
Orderinformation(PartNumber)
NTPC6A_ _ _ _ SFTP
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
None
Jacket Color
BU
stranded bare copper 26AWG
Insulation
Aluminum foil, providing 100%
coverage, foil face out.
None
Overall shield
Special orders available upon request.
Available Length
Drain wire
01
02
03
05
07
10
15
25
50
Jacket Color
BU
RD
WH
YL
GY
BK
GN
OR
OPTICAL FIBER
Drain wire
Orderinformation(PartNumber)
NTPC6A_ _ _ _ SFTP
Special orders available upon request.
Nominal Transmission Characteristics
Res.
Prop.
Delay
Delay
Skew
Ω
Max.
ns
ns
i
100m
555
50
PS
PS NEXT ACR-N
PS
ACR-F
Nominal Transmission Characteristics
Freq.
Insertion
Loss
NEXT
RL
ACR-N
ACR-F
1
3
60.0
17.0
57.0
57.4
57.0
54.0
54.4
4
4.5
53.5
17.0
49.1
45.4
50.5
46.1
42.4
Ω
8
6.3
48.6
17.0
42.3
39.3
45.6
39.3
36.3
i
1
10
7.1
47.0
17.0
39.9
37.4
44.0
36.9
34.4
4
16
9.1
43.6
17.0
34.5
33.3
40.6
31.5
30.3
8
20
10.2
42.0
17.0
31.8
31.4
39.0
28.8
28.4
25
11.4
40.3
16.0
28.9
29.4
37.3
25.9
31.25
12.9
38.7
15.1
25.9
27.5
35.7
62.5
18.6
33.6
12.1
15.0
21.2
100
24
30.1
10.0
6.1
17.4
Prop.
Delay
Delay
Skew
Max.
ns
ns
100m
555
50
Insertion
Loss
NEXT
RL
3
60.0
4.5
53.5
6.3
10
26.4
22.9
30.6
27.1
Res.
Length
Freq.
PS
PS NEXT ACR-N
PS
ACR-F
ACR-N
ACR-F
17.0
57.0
57.4
57.0
54.0
54.4
17.0
49.1
45.4
50.5
46.1
42.4
48.6
17.0
42.3
39.3
45.6
39.3
36.3
7.1
47.0
17.0
39.9
37.4
44.0
36.9
34.4
16
9.1
43.6
17.0
34.5
33.3
40.6
31.5
30.3
24.5
20
10.2
42.0
17.0
31.8
31.4
39.0
28.8
28.4
12.0
18.5
25
11.4
40.3
16.0
28.9
29.4
37.3
25.9
26.4
3.1
14.4
31.25
12.9
38.7
15.1
25.9
27.5
35.7
22.9
24.5
62.5
18.6
33.6
12.1
15.0
21.2
30.6
12.0
18.5
100
24
30.1
10.0
6.1
17.4
27.1
3.1
14.4
CABINETS
page 029
Length
page 030
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
PATCH CORD
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
PATCH CORD
FACE PLATE
SF/UTP double fully shielded twisted 4 pairs
category 5e patch cord
U/UTP unshielded twisted 4 pairs category 6
flat patch cord
MODULES
Braid
PET
Copper Conductor
HDPE Insulation
Pair
Jacket
Aluminum Foil
Jacket
Copper Conductor
HDPE Insulation
Pair
Standard
stranded bard copper 26AWG
Insulation
HDPE
Orderinformation(PartNumber)
NTPC6A_ _ _ _ SFTP
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
White-Blue/Blue,White-Orange/Orange
White-Green/Green,White-Brown/Brown
Individual pair shield
None
Available Length
02
03
05
07
10
25
50
Electrical performance guaranteed to meet or exceed
ANSI/TIA-568B Category 6 and ISO/EIC specifications.
Independently tested and verified intertek (ETL).
Ideal for Data center architectural requirements.
Stranded cable for maximum flexibility.
Available with different plug mold.
Available with different color of cable.
Available with different length.
Jacket Color
HDPE
Total number of
insulated conductors
8, twisted in 4 pairs
Color code
blue x white, orange x white,
green x white, brown x white
Individual pair shield
None
Overall shield
None
Drain wire
None
Orderinformation(PartNumber)
NTFPC6E_ _ _ _
Available Length
BU
RD
WH
YL
01
02
03
GY
BK
GN
OR
05
07
10
15
25
50
Special orders available upon request.
stranded bard copper 32AWG
Insulation
Jacket Color
BU
RD
WH
YL
GY
BK
GN
OR
OPTICAL FIBER
Drain wire
01
15
Aluminum foil, providing 100%
coverage, foil face out.
None
Overall shield
Conductor
Standard
Conductor
Conductor
Conductor
PATCH PANELS
Electrical performance guaranteed to meet or exceed
ANSI/TIA-568B Category 5e and ISO/EIC specifications.
Independently tested and verified intertek (ETL).
Ideal for Data center architectural requirements.
Stranded cable for maximum flexibility.
Available with different plug mold.
Available with different color of cable.
Available with different length.
Special orders available upon request.
Nominal Transmission Characteristics
Nominal Transmission Characteristics
Res.
Prop.
Delay
Delay
Skew
Ω
Max.
ns
ns
i
100m
555
50
Freq.
Insertion
Loss
NEXT
RL
ACR-N
ACR-F
PS
PS NEXT ACR-N
PS
ACR-F
1
3
60.0
17.0
57.0
57.4
57.0
54.0
54.4
4
4.5
53.5
17.0
49.1
45.4
50.5
46.1
42.4
8
6.3
48.6
17.0
42.3
39.3
45.6
39.3
36.3
10
7.1
47.0
17.0
39.9
37.4
44.0
36.9
34.4
16
9.1
43.6
17.0
34.5
33.3
40.6
31.5
30.3
20
10.2
42.0
17.0
31.8
31.4
39.0
28.8
28.4
25
11.4
40.3
16.0
28.9
29.4
37.3
25.9
26.4
31.25
12.9
38.7
15.1
25.9
27.5
35.7
22.9
24.5
62.5
18.6
33.6
12.1
15.0
21.2
30.6
12.0
18.5
100
24
30.1
10.0
6.1
17.4
27.1
3.1
14.4
Delay
Skew
Max.
ns
ns
20m
555
50
Length
Ω
i
Freq.
Insertion
Loss
NEXT
RL
ACR-N
ACR-F
PS
PS NEXT ACR-N
PS
ACR-F
1
3
65.0
19.0
62.0
63.3
62.0
59.0
60.3
4
4
63.0
19.0
59.0
51.2
60.5
56.5
48.2
8
5.7
58.2
19.0
52.5
45.2
55.6
49.9
42.2
10
6.3
56.6
19.0
50.2
43.3
54.0
47.7
40.3
16
8
53.2
18.0
45.2
39.2
50.6
42.6
36.2
20
9
51.6
17.5
42.6
37.2
49.0
39.9
34.2
25
10.1
50.0
17.0
39.9
35.3
47.3
37.2
32.3
31.25
11.4
48.4
16.5
37.0
33.4
45.7
34.3
30.4
62.5
16.5
43.4
14.0
26.9
27.3
40.6
24.1
24.3
100
21.3
39.9
12.0
18.6
23.3
37.1
15.8
20.3
200
31.5
34.8
9.0
3.3
17.2
31.9
0.3
14.2
250
35.9
33.1
8.0
-2.8
15.3
30.2
-5.8
12.3
CABINETS
page 031
Length
Prop.
Delay
Res.
page 032
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
FACEPLATE
FACE PLATE
MODULES
PATCH PANELS
OPTICAL FIBER
American Face Plate
035 — 044
86 Face Plate
045 — 047
Fiber Face Plate
048 — 048
Surface Mount Box
049 — 052
Uk Face Plate
053 — 056
German Face Plate
057 — 057
page 033
CABINETS
Modules
058 — 062
page 034
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
AMERICAN FACEPLATE
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
AMERICAN FACEPLATE
FACE PLATE
Faceplate
Flush Plate
Jack flush plate.
1/2/3/4/6 ports available.
Various color available .
Dimensions:114*70*9.5mm .
Increase logo design on port,easy to use
& convenient to install.
Assembly:19.5mm .
Description:Flush plate .
Order information(PartNumber)
NTFP_ _ _ _
MODULES
Jack faceplate flush type.
1/2/3/4/6 ports available.
Various color available .
Dimensions:114*70*9.5mm .
Assembly:19.5mm .
Description:Flush plate .
Order information(PartNumber)
NTFP_ _ L _ _
Number of Ports Faceplate Color
01
IV
02
AL
01
IV
WH
02
AL
05
03
WH
06
05
PATCH PANELS
03
Number of Ports Faceplate Color
06
OPTICAL FIBER
NTFPBLWH
faceplate
NTFP01WH
NTFP02WH
NTFP03WH
NTFP04WH
NTFP06WH
NTFP01LWH
NTFP02LWH
NTFP03LWH
NTFP04LWH
NTFP06LWH
faceplate
faceplate
faceplate
faceplate
faceplate
flush plate
flush plate
flush plate
flush plate
flush plate
CABINETS
page 035
page 036
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
AMERICAN FACEPLATE
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
AMERICAN FACEPLATE
NTFPRJ14FWH
NTFPRJ142FWH
Faceplate Op White/Ivory dual RJ-14 With Wiring
Faceplate Op White/ Ivory RJ-14 And F-81 Connector
Faceplate Op White/ Ivory RJ-14 And F-81 Connector
Provide quick at-the-wall connections for RJ11/RJ14
telephone and F connection video applications;
High quality plastic for superior resistance to
impacts, chemicals and solvents; mid-size
wallplates hide irregular cuts or flaws around outlets
Provide quick at-the-wall connections for RJ11/RJ14
telephone and F connection video applications;
High quality plastic for superior resistance to
impacts, chemicals and solvents; mid-size
wallplates hide irregular cuts or flaws around outlets
MODULES
NTFPRJ142WH
FACE PLATE
NTFPRJ141WH
Faceplate Op White/Ivory Single RJ-14 With Wiring
Smooth faceplate.
Integral jack and screw-type terminal block.
Mounts on mounting bracket or standard.
Electrical outlet box.
Order Information:
Smooth faceplate.
Integral jack and screw-type terminal block.
Mounts on mounting bracket or standard.
Electrical outlet box.
Order Information:
PART Number
Color
PART Number
Color
NTFPRJ141WH
WHITE
NTFPRJ142WH
WHITE
NTFPRJ142IV
IVORY
NTFPRJ142IV
IVORY
Order Information:
Order Information:
Color
PART Number
Color
WHITE
NTFPRJ142FWH
WHITE
NTFPRJ14FIV
IVORY
NTFPRJ142FIV
IVORY
NTFPF811WH
NTFPF812WH
NTFPHRJ1401WH
NTFPHDMIFWH
Faceplate Op White/Ivory Single F-81 Connector
Faceplate Op White/Ivory Dual F-81 Connector
Faceplate Op White/ Ivory RJ-14 Hanging Style With Wiring
Faceplate one HDMI and F-81 connector
PATCH PANELS
PART Number
NTFPRJ14FWH
OPTICAL FIBER
F connector module, perfect for use CATV
applications.
Includes mounting screws.
Order Information:
Order Information:
Wall phone jacks available in 4-or-6-conductor models.
Screw terminal or quick-connect termination options.
Order Information:
Order Information:
PART Number
Color
PART Number
Color
PART Number
Color
PART Number
Color
NTFPF811WH
WHITE
NTFPF812WH
WHITE
NTFPHRJ1401WH
WHITE
NTFPHDMIFWH
WHITE
NTFPF811IV
IVORY
NTFPF812IV
IVORY
NTFPHRJ1401IV
IVORY
NTFPHDMIFIV
IVORY
CABINETS
page 037
F connector module, perfect for use CATV
applications.
Includes mounting screws.
page 038
STRUCTURE CABLING
AMERICAN FACEPLATE
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
AMERICAN FACEPLATE
FACE PLATE
NTMBRJ1401WH / NTMBRJ1401IV
Faceplate Op White/ Ivory Single RJ-14 Surface Mount
Screw terminal base with snap-on cover.
Includes mounting screws and double-sided tape.
NTFPD01WH
NTFPD02WH
Decora faceplate White/Ivory Single Gang
Decora faceplate White/Ivory Two Gang
Order Information:
PART Number
Color
NTMBRJ1401WH
WHITE
NTMBRJ1401IV
IVORY
MODULES
NTMBRJ141WH / NTMBRJ141IV
Faceplate Op White/ Ivory Single RJ-14 Surface Mount
Screw terminal base with snap-on cover.
Includes mounting screws and double-sided tape.
PART Number
Color
NTMBRJ141WH
WHITE
NTMBRJ141IV
IVORY
This series offers the traditional electrical look often
requested by the residential market.
Suited for home office environment .
Ideal for multiple applications.
SIZE:125.5*124*6 mm.
Order Information:
Order Information:
PART Number
Color
PART Number
Color
NTFPD01WH
WHITE
NTFPD02WH
WHITE
NTFPD01IV
IVORY
NTFPD02IV
IVORY
NTFPD03WH
NTFPD04WH
Decora faceplate White/ Ivory Three Gang
Decora faceplate White/ Ivory Four Gang
PATCH PANELS
Order Information:
This series offers the traditional electrical look often
requested by the residential market.
Suited for home office environment.
Ideal for multiple applications.
SIZE:75*124*6 mm.
OPTICAL FIBER
NTMBRJ142WH / NTMBRJ142IV
Face plate Op White/ Ivory Dual RJ-14 Surface Mount
Screw terminal base with snap-on cover.
Includes mounting screws and double-sided tape.
Order Information:
PART Number
Color
NTMBRJ142WH
WHITE
NTMBRJ142IV
IVORY
This series offers the traditional electrical look often
requested by the residential market.
Suited for home office environment.
Ideal for multiple applications.
SIZE:172*124*6 mm.
Order Information:
Order Information:
PART Number
Color
PART Number
Color
NTFPD03WH
WHITE
NTFPD04WH
WHITE
NTFPD04IV
IVORY
NTFPD04IV
IVORY
CABINETS
page 039
This series offers the traditional electrical look often
requested by the residential market.
Suited for home office environment.
Ideal for multiple applications.
SIZE:217*124*6 mm.
page 040
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
AMERICAN FACEPLATE
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
AMERICAN FACEPLATE
NTFPDIAV02WH
NTFPDIAV02HWH
NTFPDIRJ01WH
Faceplate Insert White/ Ivory Two
Hole Vertical
Faceplate Insert White/ Ivory Two
Hole Horizontal
Faceplate Insert White/ Ivory Single
RJ-45
NTFPDIRJ02WH
FACE PLATE
NTFPDIAV01WH
Faceplate insert white/ ivory single
hole
NTFPDIRJO4WH
Faceplate Insert White/ Ivory four
RJ-45
Combine voice, data, and A/V
connectors in popular wallplate.
Combine voice, data, and A/V
connectors in popular wallplate.
MODULES
Faceplate Insert White/ Ivory Dual
RJ-45
Combine voice, and A/V connectors
in popular wallplate.
Order Information:
Combine voice, and A/V connectors
in popular wallplate.
Order Information:
Combine voice, and A/V connectors
in popular wallplate.
Order Information:
Combine voice, data, and A/V
connectors in popular wallplate.
Order Information:
Order Information:
Order Information:
PART Number
Color
PART Number
Color
PART Number
Color
PART Number
Color
PART Number
Color
PART Number
Color
NTFPDIAV01WH
WHITE
NTFPDIAV02WH
WHITE
NTFPDIAV02HWH
WHITE
NTFPDIRJ01WH
WHITE
NTFPDIRH02WH
WHITE
NTFPDIRJ04WH
WHITE
NTFPDIAV01IV
IVORY
NTFPDIAV02IV
IVORY
NTFPDIAV02HIV
IVORY
NTFPDIRJ01IV
IVORY
NTFPDIRH02IV
IVORY
NTFPDIRJ04IV
IVORY
NTFPDIAV06WH
NTFPDIAV08WH
Faceplate Insert White/ Ivory Six Hole
Faceplate Insert White/ Ivory Eight Hole
PATCH PANELS
NTFPDIAV04WH
Faceplate Insert White/ Ivory Four
Hole
NTFPDI01WH NTFPDI02WH NTFPDIF02WH NTFPDIBLWH
Faceplate Insert White/
Faceplate Insert White/
Ivory Single RJ-11/RJ-14 Insert Ivory DualRJ-11/RJ-14 Insert
Faceplate insert RJ11 and F
-81 connector
Faceplate Blank Insert
White / Ivory
OPTICAL FIBER
Combine voice, and A/V connectors
in popular wallplate.
Order Information:
Order Information:
Combine voice, and A/V connectors
in popular wallplate.
Order Information:
Order Information:
Combine voice, and A/V
connectors in popular
wallplate.
Order Information:
Provide quick at-the-wall
connections for RJ11
telephone and F connection
video applications.
Order Information:
Blank, Combine in popular
wallplate.
Order Information:
PART Number
Color
PART Number
Color
PART Number
Color
PART Number
Color
PART Number
Color
PART Number
Color
PART Number
Color
NTFPDIAV04WH
WHITE
NTFPDIAV06WH
WHITE
NTFPDIAV08WH
WHITE
NTFPDI01WH
WHITE
NTFPDI02WH
WHITE
NTFPDIF02WH
WHITE
NTFPDIBLWH
WHITE
NTFPDIAV04IV
IVORY
NTFPDIAV06IV
IVORY
NTFPDIAV08IV
IVORY
NTFPDI01IV
IVORY
NTFPDI02IV
IVORY
NTFPDIF02IV
IVORY
NTFPDIBLIV
IVORY
CABINETS
page 041
Combine voice, and A/V connectors
in popular wallplate.
Combine voice connectors
in popular wallplate.
page 042
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
AMERICAN FACEPLATE
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
AMERICAN FACEPLATE
NTFPBLWH
NTKISTWH
NTKIF81NWH
NTKIF81GWH
Back box
Face plate
Faceplate RJ45 insert st
connector
Faceplate RJ45 insert f-81
connector(nickel plating)
Faceplate RJ45 insert f-81
connector(gold plating)
FACE PLATE
NTMB24
MODULES
Size:115*72*35(mm)
Size:114*70*6(mm)
Material: ABS.
Material: ABS.
Color: White, lovry.
Color: White, lovry.
Order Information:
Ltem
NTMB24
Order Information:
Description
Size
PART Number
Color
Mounting Box
115*72*35mm
A175C-WH
WHITE
A175C-IV
IVORY
NTKIRCAWH
NTKIBDWH
NTKIBNCWH
Faceplate insert with RCA
connector
Faceplate RJ45 insert
binding connector
Faceplate RJ45 insert BNC
connector
PATCH PANELS
NTKIBLIV
NTKIHWH
NTXHDAC01424/01426
Face plate Blank RJ45 Insert
White/ Ivory
Face plate RJ45 insert white/lvory
with hole
HDMI connector
Order Information:
NTKIUSBWH
Faceplate RJ45 insert
USB connector
Faceplate RJ45 insert with hole.
Order Information:
Order Information:
PART Number
Color
PART Number
Color
PART Number
Color
NTKIBLWH
WHITE
NTKIHWH
WHITE
NTXHDAC01424
WHITE
NTKIBLIV
IVORY
NTKIHIV
IVORY
NTXHDAC01426
IVORY
CABINETS
Other colors available upon request
page 043
NTKILCBK
Faceplate RJ45 insert
LC connector
Faceplate RJ45 insert
SC connector
OPTICAL FIBER
Faceplate blank RJ45 insert.
NTKIRCA2BK NTKISCBK
Faceplate RJ45 insert
RCA connector
Other colors available upon request
page 044
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
SHUTTERED FACE PLATES
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
SHUTTERED FACE PLATE
NTSFP02WH
NTSFP01LWH
NTSFP02LWH
Shuttered Type Outlet Plate
Shuttered Type Outlet Plate
Shuttered Type Outlet Plate
Shuttered Type Outlet Plate
FACE PLATE
NTSFP01WH
MODULES
Feature: Fit for RJ45 Keystone jack .
Feature: Fit for RJ45 Keystone jack .
Size:86*86(mm)
Size:86*86(mm)
Size:86*86(mm)
Size:86*86(mm)
Assembly: 20(mm)
Assembly: 20(mm)
Assembly: 20(mm)
Assembly: 20(mm)
Material:PC/ABS.
Material:PC/ABS.
Material: PC/ABS.
Material: PC/ABS.
Color: white.
Description:one port face plate
Color: white .
Description:two port face plate
Color:white .
Description:one port face plate
Color:white .
Description:two port face plate
NTSFP04WH
NTSFP03LWH
NTSFP04LWH
Shuttered Type Outlet Plate
Shuttered Type Outlet Plate
Shuttered Type Outlet Plate
PATCH PANELS
NTSFP03WH
Shuttered Type Outlet Plate
OPTICAL FIBER
Feature: Fit for RJ45 Keystone jack .
Size:86*86(mm)
Feature: fit for RJ45 Keystone jack .
Size: 86*86(mm)
Assembly: 20(mm)
Size:86*86(mm)
Assembly: 20(mm)
Assembly: 20(mm)
Material:PC/ABS.
Assembly: 20(mm)
Material: PC/ABS.
Material: PC/ABS.
Material:PC/ABS.
Color: White .
Description: Three port face plate
Color: white .
Description: Four port face plate
Color:white .
Description:one port face plate
Color:white .
Description:two port face plate
CABINETS
page 045
Feature: Fit for RJ45 Keystone jack .
Size: 86*86(mm)
page 046
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
SHUTTERED FACE PLATE
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
86 FIBER FACE PLATE
NTSFP4502WH
NTFFP02SC
NTFFP02LC
45 Degree Outlet Plate
45 Degree Outlet Plate
Plastic panel for Fiber coupler
Plastic panel for Fiber coupler
FACE PLATE
NTSFP4501WH
MODULES
Size:86*86(mm)
Size:86*86(mm)
Assembly: 20(mm)
Assembly: 20(mm)
Material:PC/ABS.
Material:PC/ABS.
Color:white .
Description:one port face plate
Color:white .
Description:two port face plate
NTMB35
Back box
For 2 port LC type fiber coupler
NTFP-000
NTFP-910
Fiber optic outlet
Multimedia Outlet
PATCH PANELS
NTMB45
Back box
For 2 port SC type fiber coupler
OPTICAL FIBER
Feature:has been deepened,especially
suitable for Cat6 system & shielded system.
Size:86*86*45(mm)
Material:ABS.
Color:White.
Characteristics: Suitable for drop optical
fiber. Volume is small, and weight is light.
Can be installed on walls and possess the
function of mechanical protection. Able to
support several ways of connection. Able
to carry on management of optical fibers
effectively.
.
For2 port adaptor 1 port keystone Jack.
CABINETS
page 047
Size:86*86*35(mm)
Material: ABS.
Color: White.
page 048
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
SURFACE MOUNT BOX
STRUCTURE CABLING
SURFACE MOUNT BOX
NTMB01LWH
NTMB02LWH
Surface mount box (single)
Surface mount box (double)
FACE PLATE
NTMB02WH
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Surface mount box (double)
Feature: Fit for UTP keystone jack.
Material: PC/ABS.
Color: White.
Description: two port surface
mount box.
MODULES
Feature: Fit for UTP jack.
Material: PC/ABS.
Color: White.
Description: Single port surface mount box(Dust
cover).
NTMB04WH
NTMB06WH
Surface mount box(four port)
Surface mount box(six port)
NTMB01WH-B
NTMB02WH-B
Surface mount box (single)
Surface mount box (double)
PATCH PANELS
NTMB01WH
Surface mount box (single)
Feature: Fit for UTP jack.
Material: PC/ABS.
Color: White.
Description: Two port surface mount box(Dust
cover).
OPTICAL FIBER
Feature: Fit for UTP keystone jack..
Material: PC/ABS.
Color: White.
Description: Single port surface mount box.
Feature: Fit for UTP keystone jack..
Material: PC/ABS.
Color: White.
Description: Four port surface
mount box.
Feature: Fit for UTP keystone jack.
Material: PC/ABS.
Color: White.
Description: Six port surface
mount box.
Feature: Fit for all RJ45 keystone jack.
Fit for UTP Jack.
Material: PC/ABS.
Color: White.
Description: Single port surface mount box.
Feature: Fit for all RJ45 keystone jack.
Fit for UTP Jack.
Material: PC/ABS.
Color: White.
Description: Two port surface mount box.
CABINETS
page 049
page 050
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
SURFACE MOUNT BOX
STRUCTURE CABLING
SURFACE MOUNT BOX
NTMBS62WH
UTP RJ45 BOX
FTP RJ45 BOX
Order Information:
FACE PLATE
NTMB61WH
Feature:RJ45 Cat 5e/6 Module.
Description: Box (Single-port).
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Feature:RJ45 Cat 5e/6 Module.
Description: Box FTP(Double-port).
Order Information:
PART Number
Description
PART Number
Description
NTMB5E1WH
Cat 5e
NTMBS5E2WH
Cat 5e
NTMB61WH
Cat 6
NTMBS62WH
Cat 6
MODULES
NTMB62WH
NTMB5ERJ1102WH
UTP RJ45 BOX
Surface BOX
Order Information:
PART Number
Description
NTMB5E2WH
Cat 5e
NTMB62WH
Cat 6
Description: UTP CAT5E RJ45+RJ11.
PATCH PANELS
Feature:RJ45 Cat 5e/6 Module.
Description: Box (Double-port).
Order Information:
PART Number
Description
NTMB5ERJ1102WH
Cat 5e
NTMBS61WH
OPTICAL FIBER
SHIELDED RJ45 BOX
Feature: RJ45 Cat 5e/6 Module.
Description: Box Shielded (Single-port).
Order Information:
PART Number
Description
NTMBS5E1WH
Cat 5e
NTMBS61WH
Cat 6
CABINETS
page 051
page 052
STRUCTURE CABLING
UK MODULES
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
UK FACE PLATE
NTUK019
NTUK007
RJ 45 Cat 5e /6 Standard Eurostyle Modules
Face plates
Standard Face plates
FACE PLATE
NTUK001A/B
Overall dimensions 50 x 25mm.Module comply with the ISO and
EIA TIA Standard. Each shuttered module is supplied with a slide
label field and space above, this is allowed for use of self adhesive
or further labeling if required. Termination can be made using
Krone tooling, a cable tie base is positioned to the side of the IDC
blocks to relieve cable stress.
Order Information:
Description
NTUK001A
Cat 5e
NTUK001B
Cat 6
MODULES
PART Number
1 Port faceplate.
Fit for assembly 50X25mm modules.
NTUK002A/B
RJ 45 Cat 5e /6 Standard LJ6(6C) Modules
1 gang standard faceplate.
Supplied c/w fixing screws in"easy tear"poly
bags and available as 1 gang(accepts up to
2 Euro Style modules).
Fit for assembly 50X25mm modules .
Order Information:
PART Number
Description
NTUK002A
Cat 5e
NTUK002B
Cat 6
NTUK008
NTUK009
Standard Face plates
Bevelled Face plates
PATCH PANELS
Overall dimensions 39 x 25mm. Module comply with the ISO
and EIA TIA Standard. 6c modules are ideal for floor box
installations. The compact two piece design allows for a fast
and easy in saltation and results in a low profile finish.
OPTICAL FIBER
NTUK003A/B
RJ 45 Cat 5e /6 Standard Modules
Overall dimensions 50 x 25mm. Module comply with the ISO
and EIA TIA Standard. Each shuttered module is supplied with
a slide label field and space above, this is allowed for use of
self adhesive or further labeling if required. Termination can
be made using Krone tooling, a cable tie base is positioned
between the IDC blocks to relieve cable stress.
Order Information:
Description
NTUK003A
Cat 5e
NTUK003B
Cat 6
1 gang bevelled faceplate.
Supplied c/w fixing screws in"easy tear"poly
bags and available as 1 gang(accepts up to
2 Euro Style modules).
Fit for assembly 50X25mm modules.
CABINETS
page 053
PART Number
2 gang standard faceplate.
Supplied c/w fixing screws in"easy tear"poly
bags and available as 2 gang (accepts up to 4
Euro Style modules).
Fit for assembly 50X25mm modules .
page 054
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
UK FACE PLATE
STRUCTURE CABLING
UK FACE PLATE
NTUK011
Bevelled Face plates
Back box
FACE PLATE
NTUK010
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
NTUK012
Back box
2 gang bevelled faceplate.
Supplied c/w fixing screws in"easy tear"poly bags and
available as 2 gang (accepts up to 4 Euro Style modules).
Fit for assembly 50X25MM/50X16.6MM modules.
Face plates
MODULES
NTUK018
NTUK020
Face plate panel
Matching the standard British
faceplate matching keystone.
SIZE:25*50 mm.
1 gang back box 32mm depth.
Available in "easy tear" poly bags in 1 gangs-the
boxes are also available in standard(32mm)
versions.
2 gang back box 32mm depth.
Available in "easy tear" poly bags in 2 gangs-the
boxes are also available in standard(32mm)
versions.
Face plate panel
Matching LJ6C faceplate(SH018
SH036)matching keystone.
NTUK013
Back box
PATCH PANELS
NTUK021
NTUK014
Back box
1 Port faceplate.
Fit for assembly 39X25MM LJ6 modules.
NTUK036
NTUK016
OPTICAL FIBER
Face plates
Blanks
25X50mm BLANK.
NTUK017
Blanks
1 gang back box 42mm depth.
Available in"easy tear"poly bags in 1 gangs-the
boxes are also available in standard(42mm)
versions.
2 gang back box 42mm depth.
Available in"easy tear"poly bags in 2 gangs-the boxes are
also available in standard(42mm) versions.
12.5X50MM BLANK.
CABINETS
2 Port faceplate.
Fit for assembly 39X25MM LJ6 modules.
page 055
page 056
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
GERMAN FACE PLATE
NTDE-02
1 port Wall plate
2 port Wall plate
STRUCTURE CABLING
MODULES
FACE PLATE
NTDE-01
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
MODULES
1 port Wallplate for Keystone Modules, German type.
Plate 50*50mm,Frame 80*80mm.
A , for connection of keystone Jacks.
B, Connection way of the module are 45°vertical.
C, Inclusive module shutter device, avoid dust.
D, Name plate design for identification.
E, Shining structured surface parts.
F, Full shielded metal housing, usable as central grounding
position.
G, color: white.
PATCH PANELS
1 port Wallplate for Keystone Modules, German type.
Plate 50*50mm,Frame 80*80mm.
A , for connection of keystone Jacks.
B, Connection way of the module are 45°vertical.
C, Inclusive module shutter device, avoid dust.
D, Name plate design for identification.
E, Shining structured surface parts.
F, Full shielded metal housing, usable as central grounding
position.
G, color: white.
NTMBDE-03
Germamy back box
OPTICAL FIBER
PRODUCT CERTIFICATES
page 057
CABINETS
Surface Mount box.
80x80mm for keystone Wall Outlet.
Surface Mount frame for additional keystone Jack Wall
Outlet.
page 058
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
MODULES
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
MODULES
NTTKJ WH
EngineerPro® Serie Cat6E keystone jack 180°.
Telephone jack.
FACE PLATE
NTKJ1806E WH SL
CAT 5e keystone jack for RJ45.
Molding category on the front of
the jack provides quick
identification of category rating
Meet ISO/IEC 11801,TIA/EIA568C.
Own patent products.
Used for Wall Plate.
Fit for wires AWG22-26.
IDC insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC 1000V
1 minute between adjacent terminal NO change.
Material: Using PC/ABS for cover,
PC for module, phosphor bronze for IDC wire post.
Slim design to facilitate installations into compatible
faceplates, surface-mount boxes and black panels.
Reinforced cutting ledge to easily cut off
the wires on the first punch.
Easy to read termination labels.
Orderinformation(PartNumber)
NTKJ_ _ _ _ SL
The dust cap keeps debris from te
termination field and helps wires stay
in place.
5E
6E
6A
BU
RD
WH
YL
GY
BK
GN
OR
Special orders available upon request.
WH
YL
GN
NTKJ1805EWH
Cat.5e keystone jack.
YL
GN
OR
NTKJ1805EBKSLHSTP
Cat.5e keystone jack 180° half shielded
OR
Meet ISO/IEC 11801,TIA/EIA568C.
Half shlelded.
Cat.5e 180°Half Shielded.
Color:Black.
NTKJ5ESTP
Cat.5e keystone jack shielded.
Meet ISO/IEC 11801,TIA/EIA568C.
Used for Wall Plate.
Fit for wires AWG22-26.
IDC insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change.
Material: Using PC/ABS for cover, PC for module,
phosphor bronze for IDC wire post.
Cat.5e keystone jack 180°.
Slim line shape design for high density applications
Meet ISO/IEC 11801,TIA/EIA568C.
Cat.5e 90°Fully Shielded.
CABINETS
page 059
BK
WH
OPTICAL FIBER
Jacket Color
Category
Available colors
BU
RD
GY
BK
PATCH PANELS
The IDC ensures a fast and stable
connection, protecting the conductor
against environment degradation
while ensuring the highest quality
network performance.
Pair Separation Towers allow to
easily separate wires during
termination
Available colors
BU
RD
GY
MODULES
Reinforced pins increase
resistance to strain or damage
during 4-6position plug
insertion.
Own patent products.
For voice system.
Contact with gold plated
Fit for wire AWG22-26.
Meet ISO/IEC 11801,TIA/EIA568C.
Own patent products.
Used for Wall Plate.
Fit for wires AWG22-26.
Crimping
IDC insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change.
Material: Using PC/ABS for cover, PC for module,
phosphor bronze for IDC wire post.
Cat.6 keystone jack 180°.
Slim line shape design for high density applications
page 060
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
MODULES
NTIC5EWH
NTIC5EWH-1
NTIC5EWH-2
CAT5e Keystone jack shielded.
EngineerPro Serie CAT6E Keystone jack shielded.
Modular Cord Coupler 8P8C Without Wire
UTP CAT5E RJ45-RJ45 Coupler
UTP CAT5E RJ45-RJ45 Coupler
NTKJ1806ASLSTP
EngineerPro® Serie CAT6A Keystone jack shielded.
NTKJPT5EBK
NTKJPT6EBK
UTP Cat.5e Pass-thru keystone jack
RJ45-RJ45
UTP Cat6 Pass-thru keystone jack
RJ45-RJ45
NTKJPT5ESH
NTKJPT6ESH
NTICBWH
FTP Cat.5e keystone jack coupler
RJ45-RJ45
FTP Cat6 keystone jack coupler
RJ45-RJ45
In-line Connection box
OPTICAL FIBER
Meet ISO/IEC 11801,TIA/EIA568C.
Own patent products.
Fit for wires AWG22-26.
IDC insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC 1000V
1 minute between adjacent terminal NO change.
Material: Using PC/ABS for cover, PC for module, phosphor
bronze for IDC wire post.
Slim line shape design for high density applications
CABINETS
Meet ISO/IEC 11801,TIA/EIA568C.
Own patent products.
Fit for wires AWG22-26.
IDC insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC 1000V
1 minute between adjacent terminal NO change.
Material: Using PC/ABS for cover, PC for module, phosphor
bronze for IDC wire post.
Slim line shape design for high density applications
NTIC6EWH
UTP CAT6 RJ45-RJ45 Coupler
PATCH PANELS
NTKJ1806ESLSTP-B
EngineerPro® Serie CAT6E Keystone jack shielded.
MODULES
Meet ISO/IEC 11801,TIA/EIA568C.
Own patent products.
Fit for wires AWG22-26.
IDC insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC 1000V
1 minute between adjacent terminal NO change.
Material: Using PC/ABS for cover, PC for module, phosphor
bronze for IDC wire post.
Slim line shape design for high density applications
FACE PLATE
NTKJ1806ESLSTP
Meet ISO/IEC 11801,TIA/EIA568C
Own patent products.
Fit for wires AWG22-26
IDC insertion life 200 cycles
Plug insertion life 750 cycles Min
Dielectric strength: When applied AC 750V or DC 1000V
1 minute between adjacent terminal NO change
Material: Using PC/ABS for cover, PC for module, phosphor
bronze for IDC wire post.
Slim line shape design for high density applications
page 061
STRUCTURE CABLING
MODULES
NTKJ1805ESLSTP
®
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
page 062
STRUCTURE CABLING 2016 NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
2016 NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
FACE PLATE
STRUCTURE CABLING
PATCH PANELS,
MODULAR PLUGS
& NETWORK TOOLS
MODULES
PATCH PANELS
OPTICAL FIBER
page 063
065 — 084
085 — 085
086 — 088
CABINETS
Patch Panels
Modular Plug
Network Tool
page 064
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
PATCH PANELS
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
PATCH PANELS
NTBP24UPANG
Blank Flat Patch Panel.
CAT 5E patch panel.
FACE PLATE
NTBP24UP
Features
Panel mounts to any standard 19” relay rack, cabinet
or wall bracket.
Ideal for data, voice and audio/video applications.
Compatible with all styles inserts. The cutouts accept
virtually all snap-in jacks.
Clear numbering on the front provides a quick easy way
to identify cable runs.
Made of powder coated metal.
Features
Ordering Information:
Item No.
Description
NTBP24UP
19", 1U, 24ports
NTBP48UP
19", 1U, 48 ports
MODULES
Panel mounts to any standard 19” relay rack, cabinet
or wall bracket.
Ideal for data, voice and audio/video applications.
Compatible with all styles inserts. The cutouts accept
virtually all snap-in jacks.
Clear numbering on the front provides a quick easy way
to identify cable runs.
Made of powder coated metal.
Angled design enables higher density applications.
Rear Cable Management Bar attached.
Hinged Plastic Cap for dust protection.
Ordering Information:
ILtem No.
NTBP24UPANG
Description
19", 1U, 24ports
PATCH PANELS
Nitrotel’s Cat5E
180 o keystone
jacks and
EngineerPro® 180 o
Cat6E/Cat6A are
recommended to
guarantee the highest
transmission performance
Nitrotel’s Cat5E
180o keystone
jacks and
EngineerPro® 180o
Cat6E/Cat6A are
recommended to
guarantee the highest
transmission performance
Every port is individually
protected from debris and
dust by a Hinged Plastic
Cap
OPTICAL FIBER
Extended Rear Cable
Management Bars
are recommenced
to allow proper
able support.
Clear and durable
printed numbering for
easy port identification.
Angled design enables
higher rack density by
allowing patch cords to be
routed directly into vertical
cable managers on each side
of the rack. That way the need
for horizontal cable managers
is minimized.
CABINETS
page 065
page 066
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
PATCH PANELS
STRUCTURE CABLING
PATCH PANELS
Cat.5e Multicolor patch panel.
CAT 5E patch panel.
Features
Features
Ordering Information:
Description
.
Multicolor
45o ports
Professional design, plastic cover with plastic
cover that generates an enhanced appearance.
Printed port numbering.
Clear plastic label holders.
Meet ISO/IEC 11801,TIA/EIA568C.
Fit for wires AWG22-26.
Plug insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change
Material: Using PC/ABS for cover, PC for module,
phosphor bronze for IDC wire post.
110 type IDC color coded wiring blocks for easy
cable lacing.
Ordering Information:
19", 1U, 24ports
Item No.
Description
NTPP5E48U
19",2U, 48 ports
NTPPM455E24U
19",1U, 24ports
NTPPM455E48U
19", 2U, 48 ports
NTPPPCB5E24U
Cat.5e Multicolor patch panel.
Cat.5e Multicolor patch panel.
Features
Features
Order Information:
NTPPM5E48U
Ordering Information:
Description
19", 1U, 24ports
19", 2U, 48 ports
Item No.
CABINETS
NTPPM5E24U
PCV unitary type.
Professional design, plastic cover with plastic
cover that generates an enhanced appearance.
Printed port numbering.
Clear plastic label holders.
Meet ISO/IEC 11801,TIA/EIA568C.
Fit for wires AWG22-26.
Plug insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change
Material: Using PC/ABS for cover, PC for module,
phosphor bronze for IDC wire post.
110 type IDC color coded wiring blocks for easy
cable lacing.
OPTICAL FIBER
Multicolor
Professional design, plastic cover with plastic
cover that generates an enhanced appearance.
Printed port numbering.
Clear plastic label holders.
Meet ISO/IEC 11801,TIA/EIA568C.
Fit for wires AWG22-26.
Plug insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change
Material: Using PC/ABS for cover, PC for module,
phosphor bronze for IDC wire post.
110 type IDC color coded wiring blocks for easy
cable lacing.
Item No.
PATCH PANELS
NTPP5E24U
NTPPM5E24U
MODULES
Professional design, plastic cover with plastic
cover that generates an enhanced appearance.
Printed port numbering.
Clear plastic label holders.
Meet ISO/IEC 11801,TIA/EIA568C.
Fit for wires AWG22-26.
Plug insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change
Material: Using PC/ABS for cover, PC for module,
phosphor bronze for IDC wire post.
110 type IDC color coded wiring blocks for easy
cable lacing.
page 067
FACE PLATE
NTPPM455E24U
NTPP5E24U
Item No.
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Description
NTPPPCB5E24U
19", 1U, 24ports
NTPPPCB5E48U
19", 2U, 48 ports
page 068
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
PATCH PANELS
STRUCTURE CABLING
PATCH PANELS
FACE PLATE
NTPPK5E24U
NTPPK6E24U
Cat.5e Krone Type Patch Panel.
EngineerPro® Cat.6e Krone Type Patch Panel.
Features
Features
British type.
Professional design, plastic cover with plastic
cover that generates an enhanced appearance.
Printed port numbering.
Clear plastic label holders.
Meet ISO/IEC 11801,TIA/EIA568C.
Fit for wires AWG22-26.
Plug insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change
Material: Using PC/ABS for cover, PC for module,
phosphor bronze for IDC wire post.
Krone IDC
Ordering Information:
Item No.
MODULES
British type.
Professional design, plastic cover with plastic
cover that generates an enhanced appearance.
Printed port numbering.
Clear plastic label holders.
Meet ISO/IEC 11801,TIA/EIA568C.
Fit for wires AWG22-26.
Plug insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change
Material: Using PC/ABS for cover, PC for module,
phosphor bronze for IDC wire post.
Krone IDC
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Ordering Information:
Description
Item No.
Description
19", 1U, 16 ports
NTPPK6E16U
19", 1U, 16 ports
NTPPK5E24U
19", 1U, 24 ports
NTPPK6E24U
19", 1U, 24 ports
NTPPK5E48U
19", 2U, 48 ports
NTPPK6E48U
19", 2U, 48 ports
PATCH PANELS
NTPPK5E16U
NTPP6E24U
EngineerPro® CAT 6E Patch Panel.
Features
EngineerPro® Cat.6A Patch Panel.
Ordering Information:
Description
NTPP6E16U
19", 1U, 16 ports
NTPP6E24U
19", 1U, 24 ports
NTPP6E48U
19", 2U, 48 ports
Professional design, metal panel with hinged plastic door
for dust protection.
Printed port numbering.
Loaded with EngineerPro® Cat.6A keystone jacks.
Exclusive zigzag design for maximum alien crosstalk
suppression.
Meet ISO/IEC 11801,TIA/EIA568C.
Fit for wires AWG22-26.
Plug insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change
110 IDC.
Ordering Information:
Item No.
NTPP6A24U
Description
19", 1U, 24ports
CABINETS
069
Item No.
Features
OPTICAL FIBER
Professional design, plastic cover with plastic
cover that generates an enhanced appearance.
Printed port numbering.
Clear plastic label holders.
Meet ISO/IEC 11801,TIA/EIA568C.
Fit for wires AWG22-26.
Plug insertion life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength: When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change
Material: Using PC/ABS for cover, PC for module,
phosphor bronze for IDC wire post.
110 type IDC color coded wiring blocks for easy
cable lacing.
page
NTPP6A24U
page 070
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
PATCH PANELS
STRUCTURE CABLING
PATCH PANELS
NTHDPP5E24U
Right angle Cat.5e patch panel.
High density Cat.5e patch panel.
Parameter
Parameter
EngineerPro® Right angle Cat.6 patch panel.
Meet ISO/IEC 11801,TIA/EIA568B.
0.5U Space.
Have connector & cable management,
convenient for using High-quality guaranteed.
MODULES
NTRAP6E48U
FACE PLATE
NTRAP5E48U
Meet ISO/IEC 11801,TIA/EIA568B.
1U Space.
Have connector & cable management,
convenient for using High-quality guaranteed.
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
NTHDPP6E24U
High density Cat.6 patch panel.
Parameter
Meet ISO/IEC 11801,TIA/EIA568B.
1U Space.
Have connector & cable management,
convenient for using High-quality guaranteed.
Parameter
Meet ISO/IEC 11801,TIA/EIA568B.
0.5U Space.
Have connector & cable management,
convenient for using High-quality guaranteed.
PATCH PANELS
NTPPT5E24U
Pass-thru Cat.5e patch panel.
NTPP5E24USH
Parameter
Cat.5e patch panel.
Matching 19"cabinet/framework.
Install 24PCS Cat5e coupler.
Pass-thru Cat.6 patch panel.
Parameter
Matching 19"cabinet/framework.
Install 24PCS Cat6 coupler.
24 Ports CAT5E Full Shielded Type Patch Panel
(FTP).
Own patent products.
Have connector & cable management,convenient
for using High-quality guaranteed.
Fit for wires AWG22-26.
Plug omsertopm life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength:When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change.
Material:Using PC/ABS for cover,PC for module,
phosphor bronze for IDC wire post.
OPTICAL FIBER
NTPPT6E24U
Parameter
The special design of screws for fixing
cover and bottom in the middle of panel
facilitates the subsequent construction
and maintenance. ---- If screws are on
sides of panel, after fixing cables, it is
not convenient to remove screws.
CABINETS
page 073
page 074
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
PATCH PANELS
STRUCTURE CABLING
PATCH PANELS
NTPP6E24USH
Cat.5e patch panel.
EngineerPro® CAT 6 shielded patch panel.
Parameter
Parameter
24 Ports CAT6 Full Shielded Type
Patch Panel(FTP).
Have connector & cable management,
convenient for using High-quality guaranteed.
Fit for wires AWG22-26.
Plug omsertopm life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength:When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change.
Material:Using PC/ABS for cover,PC for module,
phosphor bronze for IDC wire post.
MODULES
The special design of screws for fixing
cover and bottom in the middle of panel
facilitates the subsequent construction
and maintenance. ---- If screws are on
sides of panel, after fixing cables, it is
not convenient to remove screws.
FACE PLATE
NTPP5E24SH
24 Ports CAT5E Full Shielded Type Patch Panel
(FTP).
Have connector & cable management,convenient
for using High-quality guaranteed.
Fit for wires AWG22-26.
Plug omsertopm life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength:When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change.
Material:Using PC/ABS for cover,PC for module,
phosphor bronze for IDC wire post.
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
PATCH PANELS
NTPP6E24USH-B
NTPP6A24USH
EngineerPro® CAT 6 shielded patch panel.
EngineerPro® CAT 6A shielded patch panel.
Parameter
Parameter
OPTICAL FIBER
24 ports cat6 full shielded type patch
panel(FTP).
Have connector & cable management,
convenient for using High-quality guaranteed.
Fit for wires AWG22-26.
Plug omsertopm life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength:When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change.
Material:Using PC/ABS for cover,PC for module,
phosphor bronze for IDC wire post.
24 Ports CAT6A Full Shielded Type Patch
Panel(FTP).
Own patent products.
Have connector & cable management,convenient
for using High-quality guaranteed.
Fit for wires AWG22-26.
Plug omsertopm life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength:When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change.
Material:Using PC/ABS for cover,PC for module,
phosphor bronze for IDC wire post.
The special design of screws for fixing
cover and bottom in the middle of panel
facilitates the subsequent construction
and maintenance. ---- If screws are on
sides of panel, after fixing cables, it is
not convenient to remove screws.
CABINETS
page 075
page 076
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
PATCH PANELS
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
PATCH PANELS
NTPP5E08USH
NTPP6E08USH
NTPP6A08USH
EngineerPro® CAT 6A shielded patch panel.
Cat5e shielded 8 ports patch panel.
EngineerPro® cat6 shielded 8 ports
patch panel.
EngineerPro® Cat6A shielded 8 ports
patch panel.
FACE PLATE
NTPP6A24USH-B
Parameter
MODULES
24 ports cat6a full shielded type patch
panel(FTP).
Have connector & cable management,
convenient for using High-quality guaranteed.
Fit for wires AWG22-26.
Plug omsertopm life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength:When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change.
Material:Using PC/ABS for cover,PC for module,
phosphor bronze for IDC wire post.
NTPP5E12U-B
NTPP6E12U
Cat.5e patch panel.
Cat.5e patch panel.
Cat.6 patch panel.
Meet ISO/IEC 11801,TIA/EIA568C.
Fit for Installing at the narrow work
area.
Panel make of metal,others plastic.
110 IDC.
12 port patch panel.
Parameter
Meet ISO/IEC 11801,TIA/EIA568C.
Fit for Installing at the narrow work
area.
Plastic face plate.
DUAL IDC.
12 port patch panel.
EngineerPro® Shielded 12 ports patch panel.
NTPP5E12USH-B
NTPP6E12USH-B
Cat5e shielded 12 ports patch panel(with boot).
EngineerPro® cat6 shielded 12 ports patch
panel(with boot).
OPTICAL FIBER
Parameter
NTPP6E12USH
Shielded 12 ports patch panel.
PATCH PANELS
NTPP5E12U
NTPP5E12USH
Parameter
Meet ISO/IEC 11801,TIA/EIA568C.
Fit for Installing at the narrow work
area.
Plastic face plate.
DUAL IDC.
12 port patch panel.
CABINETS
page 077
page 078
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
PATCH PANELS
STRUCTURE CABLING
PATCH PANELS
NTVPP50U-B
Voice patch panel.
Voice patch panel.
Parameter
Parameter
FACE PLATE
NTVPP25U
50 Ports Voice Patch Panel(8P4C).
Fit for wires AWG22-26.
Plug omsertopm life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength:When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change.
Material:Using PC/ABS for cover,PC for module,
phosphor bronze for IDC wire post.
MODULES
25 Ports Voice Patch Panel(8P4C).
Have connector & cable management,convenient
for using High-quality guaranteed.
Fit for wires AWG22-26.
Plug omsertopm life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength:When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change.
Material:Using PC/ABS for cover,PC for module,
phosphor bronze for IDC wire post.
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
NTBP24UP
24 ports blank patch panel.
NTVPP50U
Voice patch panel.
Parameter
Voice patch panel.
NTBP24UPSH
24 ports shielded blank patch panel.
NT-SBP-1U
OPTICAL FIBER
NTVPP25U-B
PATCH PANELS
50 Ports Voice Patch Panel(8P4C).
Have connector & cable management,convenient
for using High-quality guaranteed.
Fit for wires AWG22-26.
Plug omsertopm life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength:When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change.
Material:Using PC/ABS for cover,PC for module,
phosphor bronze for IDC wire post.
1U blank panel.
Parameter
25 Ports Voice Patch Panel(8P4C).
Fit for wires AWG22-26.
Plug omsertopm life 200 cycles.
Plug insertion life 750 cycles Min.
Dielectric strength:When applied AC 750V or DC
1000V 1 minute between adjacent terminal NO
change.
Material:Using PC/ABS for cover,PC for module,
phosphor bronze for IDC wire post.
NT-SBP-2U
2U blank panel.
CABINETS
page 079
page 080
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
CABLE MANAGEMENT
STRUCTURE CABLING
CABLE MANAGEMENT
NTCMF5R1U
Nitrotel 1U cable manager full p lastic 5 rings.
NTCM3R1U
MODULES
NTCM5R2U
FACE PLATE
NTCM5R1U
Nitrotel 1u cable manager 5 rings.
Nitrotel 2u cable manager 5 rings.
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Nitrotel Cable manager 3 rings(10”).
NTBRP1U
N itrotel 1U Brush panel.
NTCM4R2U
Nitrotel 1U Cable manager 7 rings.
Nitrotel 2u cable manager 4 rings.
PATCH PANELS
NTCM4R1U
Nitrotel 1u cable manager 4 rings.
NTCM7R1U
OPTICAL FIBER
NTCM1U/NTCM2U
Nitrotel Cable manager (Metal Cover).
NTCMF1U/NTCMF2U
Nitrotel 1U/2U cable manager full plastic.
CABINETS
page 081
page 082
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
PATCH PANELS
Parameter
Parameter
NTWB100PRKIT
Nitrotel 100 pairs termination kits , With legs.
NTRMB100PR
Nitrotel 100 pairs termination kits , Without leg.
MODULES
NTC5CLIP
Nitrotel 110 Type connecting blocks.
STRUCTURE CABLING
PATCH PANELS
FACE PLATE
NTC4CLIP
Nitrotel 110 Type connecting blocks.
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Meet ISO/IEC 11801 and TIA/EIA568C.
Suitable for Cat.5e and Lan cable.
Connect at least 500 times.
4 pairs connecting block.
Meet ISO/IEC 11801 and TIA/EIA568C.
Suitable for Cat.5e and Lan cable.
Connect at least 500 times.
5 pairs connecting block.
NTPPWB100PRKIT
Nitrotel rack mount panel 100 pairs termination kits.
Parameter
Parameter
OPTICAL FIBER
NTRMB50PR
Nitrotel 50 pairs termination kits.
PATCH PANELS
NTWBB50PRKIT
Nitrotel 50 pairs termination kits.
110 wiring block with legs.
Designed for narrow work areas.
110 wiring block with legs.
For installation on standard 19″racks or cabinets.
CABINETS
page 083
page 084
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
MODULAR PLUG
STRUCTURE CABLING
MODULAR PLUG
NTMP6P4C
NTMP6E
NTPD110K
NTCS225
NTCS312
Telephone plug 6P4C
3U Unshielded.
Cat.6 Modular Plug 8P8C
3U-50U Unshielded.
IDC impact tool.
Stripper.
Coaxial cable stripper.
NTMP6ESH
NTMP6A
NTMPEASH
Cat.6 Modular Plug 8P8C
3U-50U shielded.
Cat.6A Modular Plug 8P8C
3U-50U unshielded.
.
Cat.6A Modular Plug 8P8C
3U-50U shielded.
NTPD314
NTPD324
NTCS501
IDC impact tool.
Impact tool.
Coaxial cable stripper.
NT100PG02
NT110PG04
110 Patch Plug.
110 Patch Plug.
PATCH PANELS
NT110PG01
MODULES
NTMB5ESH
Cat.5e Modular Plug 8P8C
3U-50U Shielded.
FACE PLATE
NTMP5E
Cat.5e Modular Plug 8P8C
3U-50U Unshielded.
110 Patch Plug.
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
NTCS601
NTPD602
NTPD603
Plastic 100 tool w/stripper.
Impact tool.
Impact tool with 5 pairs.
OPTICAL FIBER
STRAIN RELIEF MODULAR BOOT
Ordering information(PartNumber)
NTCB_ _
Jacket Color
BU
RD
GY
GN
WH
BK
YL
PR
CABINETS
page 085
page 086
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
NETWORK TOOL
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
NETWORK TOOL
NTCT203
NTCT206
NTCT313
NTCT568A
NTCT568B
Crimping tool 8P+6P+4P.
Crimping tool 8P+6P 6P+4P.
Duplex crimping tool for RJ45.
Crimping Tool
8P+6P
6P+4P.
Crimping tool
8P+6P
6P+4P.
FACE PLATE
NTCT201
Crimping tool for Rj45.
MODULES
NTCT208
NTCT216
NTNCT-258
NTNCT-268
NTNCT-278
Crimping tool 8P+6P+4P.
Crimping tool 8P+6P.
Cable tester.
4 in 1 Cable tester.
5 in 1 Cable tester.
NTCT218
NTCT294/CTCT296
NTCT301
NTNCT-288
NTNCT-468
BNC crimping tool.
Cable tester.
Fit for RJ11 , RJ12 .
PATCH PANELS
NTCT207
Crimping tool 8P+6P+4P.
Crimping tool 8P+6P 6P+4P.
Crimping tool for RJ11
Crimping tool for RJ12.
OPTICAL FIBER
CABINETS
page 087
page 088
STRUCTURE CABLING 2016 NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
2016 NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
OPTICAL FIBER
FACE PLATE
.
MODULES
PATCH PANELS
OPTICAL FIBER
page 089
091
104
105
106
—
—
—
—
103
104
105
109
CABINETS
Outdoor Optical Fiber
Optical Fiber Patch Cord
Optical Fiber Adapter
Optical Fiber Distribution Box
page 090
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
OPTICAL FIBER
STRUCTURE CABLING
OPTICAL FIBER
Unitube Non-armored Cable (GYXTY)
Introduction
PE Sheath
PSP
Tube Filling Compound
Loose Tube
Strength Member
Fiber
Water Blocking Tape
Introduction
PE Sheath
In the Nitrotel GYXTY cable, single-mode/multimode fibers
are positioned in the loose tube, which is made of high
modulus plastic materials and filled with filling compound.
The loose tube is covered with water blocking materials to
guarantee the compactness and longitudinal water-blocking
performance. Two parallel steel wires are placed at both
sides of the cable core while a PE sheath is extruded over it.
Water Blocking Material
Tube Filling Compound
Steel Wire
Fiber
MODULES
In the Nitrotel GYXTW cable, single-mode/multimode fibers
are positioned in the loose tube, which is made of high
modulus plastic materials and filled with filling compound. A
PSP is longitudinally applied around the loose tube, and
water-blocking materials are distributed into interstices
between them to guarantee the compactness and
longitudinal water blocking performance. Two parallel steel
wires are placed at both sides of the cable core while a PE
sheath is extruded over it.
Loose Tube
Fiber color code
Fiber color code
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Order Information and Characteristics of Optical Cables
Fiber Count
Order Information and Characteristics of Optical Cables
Tube
Sheath
Cable
Cable
Tensile Strength
Crush Resistance
Diameter
Thickness
Diameter
Weight
Long/ShortTerm
Long/ShortTerm
mm
mm
mm
kg/km
N
N/100 mm
Cable Type
(increased by 2 fibers)
Fiber Count
Tube
Sheath
Cable
Cable
Tensile Strength
Crush Resistance
Diameter
Thickness
Diameter
Weight
Long/ShortTerm
Long/ShortTerm
mm
mm
mm
kg/km
N
N/100 mm
NT-GYXTW-2~12Xn
2~12
2.0/3.0
2.6
10.2
105
600/1500
1000/3000
NT-GYXTY-2~12Xn
2~12
2.0/3.0
2.6
8.5
72
600/1500
1000/3000
NT-GYXTW-2~12Xn
2~12
2.0/3.0
3.0
11.0
132
1000/3000
1000/3000
NT-GYXTY-2~12Xn
2~12
2.0/3.0
3.0
9.5
98
1000/3000
1000/3000
NT-GYXTW-2~24Xn
2~24
2.8/4.0
2.6
12.2
142
600/1500
1000/3000
NT-GYXTY-2~24Xn
2~24
2.8/4.0
2.6
9.5
86
600/1500
1000/3000
NT-GYXTW-2~24Xn
2~24
2.8/4.0
3.0
13.0
170
1000/3000
1000/3000
NT-GYXTY-2~24Xn
2~24
2.8/4.0
3.0
10.2
111
1000/3000
1000/3000
Note:
1. Suffix Xn denotes fiber type and see details in Nitrotel cable coding illustration.
2. The color arrangement of fiber and tube is specified in color identification table.
Excellent mechanical and temperature performance
guaranteed by the accurate excess fiber length
Critical protection to fibers, based on the excellent
hydrolysis resistance and strength performance
of tube material and special filling compound filled in
the tube
Special compact structure to avoid the loose
tube shrinkage
Excellent crush resistance and flexibility
PSP improves the moisture penetration resistance
performance
Two parallel steel wires could guarantee the tensile
strength
Excellent ultraviolet prevention with PE sheath
Small diameter, light weight and installation
friendliness
Application: Duct/Aerial/Direct buried
Temperature requirement
Temperature cycling test
Note:
1. Suffix Xn denotes fiber type and see details in Nitrotel cable coding illustration.
2. The color arrangement of fiber and tube is specified in color identification table.
Operation
-40℃~+70℃
Installation
-10℃~+70℃
Storage/transportation
-40℃~+70℃
conform to IEC 794-1-F1
Static
10 times of outer diameter
Dynamic
20 times of outer diameter
Bending Radius
Characteristics
Excellent mechanical and temperature performance
guaranteed by the accurate excess fiber length.
Critical protection to fibers, based on the excellent
hydrolysis resistance and strength performance of tube
material and special filling compound filled in the tube.
Special compact structure to avoid the loose tube
shrinkage
Excellent crush resistance and flexibility
Two parallel steel wires could guarantee the tensile
strength
Excellent ultraviolet prevention with PE sheath
S m a l l d i a m e t e r, l i g h t w e i g h t a n d i n s t a l l a t i o n
friendliness
Application: Duct/Aerial
Temperature requirement
Temperature cycling test
Operation
-40℃~+70℃
Installation
-10℃~+70℃
Storage/transportation
-40℃~+70℃
OPTICAL FIBER
Characteristics
PATCH PANELS
(increased by 2 fibers)
FACE PLATE
Unitube Light-armored Cable (GYXTW)
Cable Type
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
conform to IEC 794-1-F1
Static
10 times of outer diameter
Dynamic
20 times of outer diameter
Bending Radius
CABINETS
page 091
page 092
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
OPTICAL FIBER
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
OPTICAL FIBER
FACE PLATE
Stranded Loose Tube Cable with Steel Tape (GYTS)
Stranded Loose Tube Cable with Aluminum Tape (GYTA)
Fig 1
Fig 1
Introduction
PE Sheath
PSP
Fiber
Tube filling compound
Loose tube
Strength Member
Cable Filling Compound
In the Nitrotel GYTA cable, single-mode/multimode fibers are
positioned in the loose tubes, which are made of high
modulus plastic materials, while the loose tubes strand
together around metallic central strength member into a
compact and circular cable core. For certain high fibre count
cables, the strength member would be covered with
polyethylene (PE). The water-blocking materials are
distributed into interstices of the cable core, and the
Aluminum Polyethylene Laminate (APL) is longitudinally
applied around the cable core before a PE sheath is
extruded over it.
PE Sheath
APL
Fiber
Tube filling compound
Loose tube
Strength Member
Cable Filling Compound
MODULES
In the Nitrotel GYTS cable, single-mode/multimode fibers
are positioned in the loose tubes, which are made of high
modulus plastic materials, while the loose tubes strand
together around metallic central strength member into a
compact and circular cable core. For certain high fiber count
cables, the strength member would be covered with
polyethylene (PE). The water-blocking materials are
distributed into interstices of the cable core, and the PSP is
longitudinally applied around the cable core before a PE
sheath is extruded over it.
Introduction
Fiber color code
Fiber color code
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Fiber color in each tube starts from No. 1 Blue.
Fiber color in each tube starts from No. 1 Blue.
Color codes for loose tube & filler rod
Color codes for loose tube & filler rod
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Cable Type
(increased by 2 fibers)
Fiber Count
Cable
Cable
Tensile Strength
Crush Resistance
&
Fibers in
Diameter
Weight
Long/ShortTerm
Long/ShortTerm
Fillers
each Tube
mm
kg/km
N
N/100 mm
NT-GYTS-2~30Xn
2~30
5
6
9.8
108
600/1500
300/1000
NT-GYTS-32~36Xn
32~36
6
6
10.4
129
600/1500
300/1000
NT-GYTS-38~60Xn
38~60
5
12
10.6
132
600/1500
300/1000
NT-GYTS-62~72Xn
62~72
6
12
12.1
161
600/1500
300/1000
5
6
7
8
9
10
11
12
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature.
Fiber Count
Tube
&
Fillers
Max. No. of
Fibers in
each Tube
NT-GYTA-2~30Xn
2~30
5
6
9.2
85
600/1500
300/1000
NT-GYTA-32~36Xn
32~36
6
6
10.2
107
600/1500
300/1000
NT-GYTA-38~60Xn
38~60
5
12
10.4
110
600/1500
300/1000
NT-GYTA-62~72Xn
62~72
6
12
11.4
130
600/1500
300/1000
74~96
8
12
13.6
198
600/1500
300/1000
98~120
10
12
15.4
260
600/1500
300/1000
NT-GYTS-122~144Xn
122~144
12
12
17.2
286
600/1500
300/1000
Note:
1.Suffix Xn denotes fiber type and see details in Nitrotel cable coding illustration.
2.The color arrangement of fiber and tube is specified in color identification table.
3.The normal PE sheath thickness is 1.8mm.
Temperature requirement
Temperature cycling test
Bending Radius
(increased by 2 fibers)
Cable
Diameter
mm
Cable
Weight
kg/km
Tensile Strength
Long/ShortTerm
N
Crush Resistance
Long/ShortTerm
N/100 mm
NT-GYTA-74~96Xn
74~96
8
12
13.6
165
600/1500
300/1000
NT-GYTA-98~120Xn
98~120
10
12
14.8
195
600/2000
300/1000
NT-GYTA-122~144Xn
122~144
12
12
16.4
236
600/2500
300/1000
NT-GYTA-146~216Xn
146~216
18
12
16.4
232
600/2500
300/1000
NT-GYTA-218~288Xn
218~288
24
12
20.0
300
1000/3000
300/1000
Note:
1.Suffix Xn denotes fibre type and see details in Nitrotel cable coding illustration.
2.The color arrangement of fibre and tube is specified in color identification table.
3.The normal PE sheath thickness is 1.8mm.
Operation
-40℃~+70℃
Installation
-10℃~+70℃
Storage/transportation
-40℃~+70℃
conform to IEC 794-1-F1
Static
10 times of outer diameter
Dynamic
20 times of outer diameter
Fig 2: High Fiber Count Cable
Fiber
PSP
Cable Filling Compound
PE Sheath
Excellent mechanical and temperature performance guaranteed
by the accurate excess fiber length
Critical protection to fibers, based on the excellent hydrolysis
resistance and strength performance of tube material and special
filling compound filled in the tube
Excellent ultraviolet prevention with PE sheath
The following measures are taken to ensure the water
blocking performance of the cable:
Fig 2 and
- Single steel wire used as the central strength
member
- Special water-blocking filling compound in the
loose tube
- 100% cable core filling
- APL moisture barrier
Application: Duct/Aeria
Operation
-40℃~+70℃
Installation
-10℃~+70℃
Storage/transportation
-40℃~+70℃
Temperature requirement
Temperature cycling test
Bending Radius
conform to IEC 794-1-F1
Static
10 times of outer diameter
Dynamic
20 times of outer diameter
3: High Fiber Count Cable
Fiber
PE Sheath
Tube Filling Compound
PE Sheath
Cable Filling Compound
Fiber
PE Sheath
Cable Filling Compound
PE Sheath
Tube Filling Compound
PE Outer Sheath
APL
APL
PSP
Tube Filling Compound
Loose Tube
Strength Member
Strength Member
Loose Tube
Strength Member
CABINETS
PE Sheath
Characteristic
Loose Tube
Water-blocking Material
OPTICAL FIBER
NT-GYTS-74~96Xn
NT-GYTS-98~120Xn
Excellent mechanical and temperature performance guaranteed
by the accurate excess fiber length
Critical protection to fibers, based on the excellent hydrolysis
resistance and strength performance of tube material and special
filling compound filled in the tube
Excellent crush resistance and flexibility
Excellent ultraviolet prevention with PE sheath
The following measures are taken to ensure the water blocking
performance of the cable:
- Single steel wire used as the central strength
member
- Special water-blocking filling compound in the loose tube
- 100% cable core filling
- PSP moisture barrier
Application: Duct/Aeria
4
Brown
Cable Type
Max. No. of
Characteristic
3
Green
Order Information and Characteristics of Optical Cables
Order Information and Characteristics of Optical Cables
Tube
2
Orange
PATCH PANELS
Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature.
1
Blue
PE Inner Sheath
page 093
Strenght Member
PE Sheath
Cable Filling Compound
Loose Tube
Fiber
page 094
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
OPTICAL FIBER
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
OPTICAL FIBER
FACE PLATE
Stranded Loose Tube Cable with Aluminum Tape and
Steel Tape (Double Sheaths) (GYTA53)
Stranded Loose Tube Cable with Steel Tape
(Double Sheaths) (GYTY53)
Introduction
Introduction
PE Outer Sheath
PSP
Filler
PE Inner Sheath
Cable Filling Compound
Water-blocking Material
Strength Member
Loose Tube
Fiber
Tube Filling Compound
Fiber color code
MODULES
In the Nitrotel GYTY53 cable, single-mode/multimode fibers
are positioned in the loose tubes, which are made of high
modulus plastic materials, while the loose tubes strand
together around metallic central strength member into a
compact and circular cable core. For certain high fibre count
cables, the strength member would be covered with
polyethylene (PE). The water-blocking materials are
distributed into interstices of the cable core . The cable core is
covered with a PE inner sheath, and the PSP is longitudinally
applied around the cable core before a PE outer sheath is
extruded over it.
PE Outer Sheath
PSP
Filler
Water-blocking Material
PE Inner Sheath
Fiber
Tube Filling Compound
Strength Member
APL
Loose Tube
Cable Filling Compound
In the Nitrotel GYTA53 cable, single-mode/multimode fibers are
positioned in the loose tubes, which are made of high modulus
plastic materials, while the loose tubes strand together around
metallic central strength member into a compact and circular
cable core. For certain high fibre count cables, the strength
member would be covered with polyethylene (PE). The waterblocking materials are distributed into interstices of the cable
core . An APL is longitudinally applied around the cable core,
then covered with a PE inner sheath; and the PSP is
longitudinally applied over the PE inner sheath before a PE
outer sheath is extruded over it.
Fiber color code
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Fiber color in each tube starts from No. 1 Blue.
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Color codes for loose tube & filler rod
Fiber color in each tube starts from No. 1 Blue.
Color codes for loose tube & filler rod
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature.
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
PATCH PANELS
1
Order Information and Characteristics of Optical Cables
Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature.
Cable Type
Order Information and Characteristics of Optical Cables
Cable Type
(increased by 2 fibers)
NT-GYTY53-2~36Xn
Fiber Count
2~36
Tube
&
Fillers
6
NT-GYTY53-38~72Xn
38~72
6
NT-GYTY53-74~96Xn
74~96
8
NT-GYTY53-98~120Xn
98~120
10
Max. No. of
Fibers in
each Tube
6
12
12
12
Cable
Diameter
mm
(increased by 2 fibers)
Cable
Weight
kg/km
Tensile Strength
Long/ShortTerm
N
184
12.6
Crush Resistance
Long/ShortTerm
N/100 mm
1000/3000
1000/3000
14.0
216
1000/3000
1000/3000
15.7
260
1000/3000
1000/3000
301
17.4
1000/3000
1000/3000
122~144
12
12
19.0
354
1000/3000
1000/3000
146~216
18
12
19.0
350
1000/3000
1000/3000
Cable
Diameter
mm
Cable
Weight
kg/km
Tensile Strength
Long/ShortTerm
N
Crush Resistance
Long/ShortTerm
N/100 mm
NT-GYTA53-2~36Xn
2~36
6
6
13.0
199
1000/3000
1000/3000
NT-GYTA53-38~72Xn
38~72
6
12
15.0
244
1000/3000
1000/3000
NT-GYTA53-74~96Xn
74~96
8
12
16.8
290
1000/3000
1000/3000
NT-GYTA53-98~120Xn
98~120
10
12
17.8
333
1000/3000
1000/3000
NT-GYTA53-122~144Xn
122~144
12
12
20
389
1000/3000
1000/3000
NT-GYTA53-146~216Xn
146~216
18
12
20
385
1000/3000
1000/3000
Characteristic
Characteristic
Temperature requirement
Temperature cycling test
Bending Radius
Operation
-40℃~+70℃
Installation
-10℃~+70℃
Storage/transportation
-40℃~+70℃
conform to IEC 794-1-F1
Static
10 times of outer diameter
Dynamic
20 times of outer diameter
3: High Fiber Count Cable
PE Outer Sheath
PSP
Water-blocking Material
Loose Tube
Strength Member
Fiber
Tube Filling Compound
Cable Filling Compound
PE Outer Sheath
PSP
Water-blocking Material
PE Inner Sheath
Loose Tube
Strength Member
PE Sheath
Fiber
Tube Filling Compound
Cable Filling Compound
Excellent mechanical and temperature performance guaranteed
by the accurate excess fiber length
Critical protection to fibers, based on the excellent hydrolysis
resistance and strength performance of tube material and special
filling compound filled in the tube
Excellent crush resistance and flexibility
The following measures are taken to ensure the water blocking
performance of the cable:
- Single steel wire used as the central strength
member
- Special water-blocking filling compound in
Fig 2 and 3:
the loose tube
- 100% cable core filling
- APL moisture barrier
- PSP moisture barrier
- Water-blocking material
Application: Duct/Aerial/Direct buried
Temperature requirement
Temperature cycling test
Bending Radius
Operation
-40℃~+70℃
Installation
-10℃~+70℃
Storage/transportation
-40℃~+70℃
conform to IEC 794-1-F1
Static
12.5 times of outer diameter
Dynamic
25 times of outer diameter
High Fiber Count Cable
PE Outer Sheath
PE Outer Sheath
PSP
Water-blocking Material
PE Inner Sheath
Fiber
Tube Filling Compound
Strength Member
PE Sheath
APL
Loose Tube
Cable Filling Compound
PSP
Water-blocking Material
PE Inner Sheath
APL
CABINETS
PE Inner Sheath
PE Sheath
page 095
Max. No. of
Fibers in
each Tube
Note:
1.Suffix Xn denotes fiber type and see details in Nitrotel cable coding illustration.
2.The color arrangement of fiber and tube is specified in color identification table.
3.The normal PE sheath thickness is 1.0mm, and PE outer sheath thickness is 2.0mm.
Note:
1.Suffix Xn denotes fiber type and see details in Nitrotel cable coding illustration.
2.The color arrangement of fiber and tube is specified in color identification table.
3.The normal PE sheath thickness is 1.0mm, and PE outer sheath thickness is 2.0mm.
Excellent mechanical and temperature performance guaranteed
by the accurate excess fiber length
Critical protection to fibers, based on the excellent hydrolysis
resistance and strength performance of tube material and special
filling compound filled in the tube
Excellent crush resistance and flexibility
The following measures are taken to ensure the water blocking
performance of the cable:
- Single steel wire used as the central strength
Fig 2 and
member
- Special water-blocking filling compound in
the loose tube
- 100% cable core filling
- PSP moisture barrier
- Water-blocking material
Application: Duct/Aeria
Tube
&
Fillers
OPTICAL FIBER
NT-GYTY53-122~144Xn
NT-GYTY53-146~216Xn
Fiber Count
Loose Tube
PE Sheath
Strength Member
Fiber
Tube Filling Compound
Cable Filling Compound
page 096
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
OPTICAL FIBER
STRUCTURE CABLING
OPTICAL FIBER
Figure-8 Cable with Steel Tape (GYTC8S)
Introduction
Introduction
PE/At outer Sheath
Water Blocking tape
Filler
PE Inner Sheath
FRP Strenght Memeber
Fiber
Tube Filling Compound
Loose Tube
Water Blocking Yarn
In the Nitrotel GYTC8S cable, single-mode/multimode fibers are
positioned in the loose tubes, which are made of high modulus
plastic, while the loose tubes strand together around metallic central
.
strength member into a compact and circular cable core, and the
water-blocking materials are distributed into interstices of it. After a
PSP is applied around the cable core, this part of cable accompanied
with the stranded wires as the supporting part are completed with a
PE sheath to be a figure-8 structure. This kind of cable is specifically
used for self supporting aerial installation extruded over it.
Stranded Wires 7 x 1.6mm
PE Sheath
Fiber
Loose Tube
Tube Filling Compound
Cable Filling Compound
PSP
PE Sheath
Strendth Member
Fiber color code
MODULES
In the Nitrotel ADSS cable, single-mode/multimode fibers are
positioned in the loose tubes, which are made of high modulus
plastic materials, while the loose tubes strand together around
non-metallic central strength member(FRP) into a compact and
circular cable core. The loose tubes are filled with filling
compound, while water-blocking materials are distributed into
interstices of the cable core. The PE inner sheath is extruded
over the cable core with aramid yarns outside.
Then, the cable is completed with a PE/AT outer sheath.
Fiber color code
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Fiber color in each tube starts from No. 1 Blue.
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Fiber color in each tube starts from No. 1 Blue.
Color codes for loose tube & filler rod
Color codes for loose tube & filler rod
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
PATCH PANELS
Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature.
Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature.
Characteristics of Optical Cables
Operation,
Heat
Rec. Daily
Strength Modulus of
Break
Tensile
Max.
Strength Strength Member CSA Elasticity Storing, Transport Expansion
Temperature
Coefficient
Working Tension
2
2
(mm )
(kN)
(kN)
(kN/mm )
(oC)
(x10-6/K)
PE Sheath AT Sheath
(kN)
Ref. Weight
(kg/km)
Suitable Span
(NESC Standard m)
Cable
Cable Type
Tensile Strength
Crush Resistance
Weight
Long/Short Term
Long/Short Term
mm
kg/km
N
N/100 mm
2~30
9.6 x 21
270
3000/8000
300/1000
NTGYTC8S-32~36Xn
32~36
10.2 x 21.6
285
3000/8000
300/1000
280
NTGYTC8S-38~60Xn
38~60
11.6 x 23
320
3000/8000
300/1000
320
NTGYTC8S-62~72Xn
62~72
12 x 23.4
340
3000/8000
300/1000
300/1000
B
C
D
125
136
1.5
4
10
4.6
7.6
-40~+60
1.8
160
100
140
100
13.0
132
142
2.25
6
15
7.6
8.3
-40~+60
1.5
230
150
200
150
13.3
137
148
3.0
8
20
10.35
9.45
-40~+60
1.3
300
200
290
13.6
145
156
3.6
10
24
13.8
10.8
-40~+60
1.2
370
250
13.8
147
159
4.5
12
30
14.3
11.8
-40~+60
1.0
420
14.5
164
177
5.4
15
36
18.4
13.6
-40~+60
0.9
480
Cable Type
Fiber
(increased by 2 fibers)
Count
200
NTGYTC8S-2~30Xn
350
250
280
400
320
460
171
185
6.75
18
45
22.0
16.4
-40~+60
0.6
570
380
550
380
179
193
7.95
22
53
26.4
18.0
-40~+60
0.3
670
460
650
460
15.5
190
204
9.0
26
60
32.2
19.1
-40~+60
0.1
750
530
750
510
15.6
194
208
10.5
28
70
33.0
19.6
-40~+60
0.1
800
560
800
560
16.3
211
226
12.75
34
85
40.0
20.1
-40~+60
0.1
880
650
880
650
16.8
226
242
15.45
41
103
48.0
24.0
-40~+60
-0.4
1000
750
1000 760
17.2
236
253
16.2
45
108
51.0
25.1
-40~+60
-0.5
1180
800
1100 830
17.9
249
266
18.0
50
120
58.8
26.1
-40~+60
-0.8
1180
880
1180 900
74~96
14.2 x 25.6
390
3000/8000
98~120
16.0 x 27.4
430
3000/8000
300/1000
NTGYTC8S-122~144Xn
122~144
17.7 x 29.1
480
3000/8000
300/1000
Note:
1. Suffix Xn denotes fiber type and see details in Nitrotel cable coding illustration.
2. The color arrangement of fiber and tube is specified in color identification table.
3. The normal PE sheath thickness is 1.8mm.
4. The installation span should not be more than 100m and the installation sag should not be less than 0.5%. Figure-8 cable with
other span and standard 0.5% sag is available on request.
5. Dimensions of the figure-8 cable have close relationship with moulds and production process, the above-mentioned dimensions
are subject to actual dimensions
Characteristic
Characteristic
Applicable climate conditions
of cable can be divide into four categories
Wind Speed (m/s) Ice (mm) Extra Load (N/m)
A
25
0
0.7
B
35
0
0.7
C
10
5
2.5
D
10
10
4.4
Excellent mechanical and temperature performance
Critical protection to fibers, based on the excellent hydrolysis
resistance and strength performance of tube material and special
filling compound filled in the tube
The following measures are taken to ensure the water blocking
performance of the cable:
- Single steel wire used as the central strength member
- Special water-blocking filling compound in the loose tube
- 100% cable core filling
- PSP moisture barrier
Application: Duct/Aerial
CABINETS
Climate Type
NTGYTC8S-74~96Xn
NTGYTC8S-98~120Xn
OPTICAL FIBER
14.9
15.1
Easy installation
Excellent corrosion resistance, due to AT sheath
Light weight and small diameter
Large span with the largest span of over 1200m
Accurate excess fibre length and stranding pitch to guarantee the
good tensile and temperature performance
The life expectancy is over 30 years
The careful design of aramid yarn quantity and stranding process
can satisfy the demand on various spans.
For overhead power lines under 110kV, PE outer sheath is applied.
For power lines equal to or over 110kV, Anti-Tracking outer sheath
is applied.
Application: Aerial
Order Information and Characteristics of Optical Cables
Diameter
A
12.5
Note:
1. Only a part of ADSS cables are listed in the table. ADSS cables with other spans can be inquired from Nitrotel directly.
2. Specifications in the table are listed under condition that there is no height difference between two suspension points while the installation sag is 1%.
3. Fibre count is 2 to 60.
4.Specially designed cable structure is available on request.
page 097
FACE PLATE
All Dielectric Self-supporting Aerial Cable (ADSS)
Ref. Outer
Diameter
(mm)
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
page 098
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
OPTICAL FIBER
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
OPTICAL FIBER
Introduction
Single Core Tight Wrapped Indoor
Optical Cable(GJFJV)
PE Outer Sheath
Filler
Cable Filling Compound
FRP Strength Member
Loose Tube
Fiber
Tube Filling Compound
Introduction
The Nitrotel simplex cable (GJFJV) uses single 900µm or 600µm
tight buffered fibre as optical transmission medium, covered with
aramid yarn as strength member, then extruded with a PVC
sheath. Other sheath materials, like LSZH and TPU, are available
on request.
Sheath
Aramid Yam Strength Member
Tight Buffered Optical Fiber
MODULES
In the GYFTY cable, single-mode/multimode fibers are
positioned in the loose tubes, which are made of high modulus
plastic materials, while the loose tubes strand together around
non-metallic central strength member (FRP) into a compact
and circular cable core. For certain high fibre count cables, the
strength member would be covered with polyethylene (PE).
The water-blocking materials are distributed into the
interstices of the cable core. Then the cable is completed with
a PE sheath.
FACE PLATE
Stranded Loose Tube Cable with Non-metallic Central
Strength Member (GYFTY)
Fiber
Fiber color code
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Order Information and Characteristics of Optical Cables
Fiber color in each tube starts from No. 1 Blue.
Color codes for loose tube & filler rod
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Cable Type
(increased by 2 fibers)
Fiber Count
Tube
&
Fillers
Max. No. of
Fibers in
each Tube
Cable
Diameter
mm
Cable
Weight
kg/km
Tensile Strength
Long/ShortTerm
N
Crush Resistance
Long/ShortTerm
N/100 mm
2~36
6
6
10.6
92
400/1000
300/1000
38~60
5
12
11.2
102
400/1000
300/1000
NT-GYFTY-2~42Xn
2~42
7
6
11.2
103
600/1500
300/1000
NT-GYFTY-44~72Xn
44~72
6
12
12.2
114
600/1500
300/1000
NT-GYFTY-2~48Xn
2~48
8
6
12.2
125
1000/3000
300/1000
NT-GYFTY-50~96Xn
50~96
8
12
13.6
160
1000/3000
300/1000
NT-GYFTY-98~120Xn
98~120
10
12
14.6
200
1000/3000
300/1000
NT-GYFTY-122~144Xn
122~144
12
12
16.8
235
1000/3000
300/1000
8
6
16.8
220
1000/3000
300/1000
12
12
NT-GYFTY-146~192Xn
146~192
Note:
1.Suffix Xn denotes fiber type and see details in Nitrotel cable coding illustration.
2.The color arrangement of fiber and tube is specified in color identification table.
3.The normal PE sheath thickness is 2.0mm.
Characteristic
Crush Resistance
Bending Radius
Long/ShortTerm
Long/ShortTerm
Static/Dynamic
(N)
(N/100 mm)
(mm)
Storage, operating
Temperature (°C)
NT-GYJFJV-1Xn
1.6± 0.2
2.5
60/100
100/500
30/60
-20~+60
NT-GYJFJV-1Xn
1.8± 0.2
3.5
60/100
100/500
30/60
-20~+60
NT-GYJFJV-1Xn
2.8± 0.2
6.0
60/100
100.500
30/60
-20~+60
Note: Xn denotes fiber type.
Characteristic
Excellent strippability with tight buffered fiber
Excellent flame retardant properties
High tensile strength due to aramid strength member
Excellent corrosion resistant, waterproof, flame retardant and environmental- friendly properties of the outer sheath
Application
Fiber jumper or pigtail
Indoor riser level and plenum level cabling
Interconnections between instruments and communication equipments
OPTICAL FIBER
NT-GYFTY-2~36Xn
NT-GYFTY-38~60Xn
Weight (kg/km)
Tensile Strength
PATCH PANELS
Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature.
Cable Type
Cable Size (mm)
Standards
Comply with standard YD/T1258.2-2003 and IEC 60794-2-10/11
Delivery Length
Standard Reel Length: 2000m; Other lengths available on request
page 099
CABINETS
Excellent mechanical and temperature performance guaranteed
by the accurate excess fiber length
Critical protection to fibers, based on the excellent hydrolysis
resistance and strength performance of tube material and special
filling compound filled in the tube
Excellent ultraviolet prevention with PE sheath
Excellent crush resistance and flexibility
The following measures are taken to ensure the water blocking
performance of the cable:
- FRP used as the central strength member
- Special water-blocking filling compound in the loose tube
- 100% cable core filling
Application: Duct/Aerial
page 100
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
OPTICAL FIBER
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
OPTICAL FIBER
FACE PLATE
Duplex Flat Cable (GJFJBV)
Indoor Distribution Cable(GJPFJV)
Introduction
Introduction
Inner Sheath
The duplex flat cable uses two 900µm or 600µm tight
buffered fibers as optical transmission medium, covered with
aramid yarn as strength member while each fibre extruded
with a PVC inner sheath, then extruded with a flat PVC outer
sheath. Other sheath materials, like LSZH and TPU, are
available on request.
Tight buffered Fiber
In the Nitrotel GJPFJV Indoor Distribution Cable 900μm
Buffered Fibers are surrounded by aramid yarn as strength
members and a flame-retardant jacket.
Flame--retardant jacket
Tight buffered optical fiber
Aramid Yarn strength member
MODULES
Aramid Yarn
Outer Sheath
Order Information and Characteristics of Optical Cables
Cable Type
Cable Size (mm)
Weight (kg/km)
NT-GJFJBV-2Xn
(3.0± 0.2) x (5.4± 0.2)
13.8
NT-GJFJBV-2Xn
(3.8± 0.2) x (7.0± 0.2)
20
Tensile Strength
Crush Resistance
Bending Radius
Long/ShortTerm
Long/ShortTerm
Static/Dynamic
Storage, operating
Temperature (°C)
(N)
(N/100 mm)
100/200
100/500
30/60
-20~+60
100/200
100/500
40/80
-20~+60
Items
Descriptions
Items
Descriptions
Optical Fiber
Fiber count
4/8/12/ 24
short -term
600N
Tight buffer fibers
Material
LSZH/PVC
long -term
200N
Diameter
0.85 ±0.05mm
short -term
1000N (>12core)
Strength Member
Material
Aramid yarn
long -term
500N (>12core)
Sheath
Material
LSZH/PVC
short -term
1000N
Thickness
0.8mm±0.15mm (≤12 Core )
long -term
300N
Characteristics
Excellent strippability with tight buffered fiber
Excellent flame retardant properties
High tensile strength due to aramid strength member
Compact arrangement of fiber due to flat structure
Excellent corrosion resistant, waterproof, flame retardant and
environmental- friendly properties of the outer sheath
Mechanical and Environmental Characteristics
Tensile Strength
IEC 60794 -2-E1
Crush Resistance IEC 60794 -2-E3
PATCH PANELS
Note: Xn denotes fiber type.
(mm)
Cable Dimensions and Constructions
1.0mm± 0.10mm (>12core)
Color
Cable Diameter
Yellow/Orange/Aqua
5.0 ± 0.2 mm (4 Core)
6.0 ± 0.2 mm (8 Core)
6.5 ± 0.2 mm (12 Core)
7.5 ± 0.2 mm (18 Core)
8.5 ± 0.2 mm (24 Core)
Application
Approx 16.2 kg/km
Cable Weight
Approx 27.0 kg/km
Duplex fiber flexible connection jumper or pigtail
Indoor riser level and plenum level cabling
Instruments communication equipments interconnection
Approx 38.0 kg/km
Approx 45.0 kg/km
Approx 65.0 kg/km
Tight buffer Color Code
Comply with standard YD/T1258.2-2003 and IEC 60794-2-10/11
Delivery Length
OPTICAL FIBER
Standards
blue/orange/green/brown/grey/white/red/black/
yellow/purple/pink/aqua
Colors of 2 ndgroup of 12 With black tracer
blue/orange/green/brown/grey/white/red/
tight buffers
yellow/purple/pink/aqua
With white tracer
black
Standard Reel Length: 2000m; Other lengths available on request
Packing
Wooden Drums Protection
Marking
Cable Marker every Meter by
page 101
CABINETS
Project name or Project owner
Year of manufacture
Tape of Cable
Number of fiber
Cable length
Etc
page 102
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
OPTICAL FIBER
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
OPTIC FIBER PATCH CORDS
FACE PLATE
Patch Cords
FTTH Drop Cable(GJXFH-2)
Fiber patch cords provide connections from the work area to
the wall outlet or from active equipment to the patch panel.
Cords are available as duplex or simplex 62.5/125,50/125,
MM or SM fibers. we offer ST,SC,FC or LC connectors.
All patch cords are factory polished and 100% optically tested
for superior performance.
Introduction
Introduction
LSZH jacket
KFRP strength member
Fiber(G.657.A2)
Insertion loss:≤0.3dB
Return loss: Pc≥40dB APC≥60dB
MODULES
This flat drop cable, which consists of 1, 2, or 4 color coded
optical fibers, offers an ideal solution for the smaller fiber
counts that are needed in the final sections of an optical
network. Two parallel FRP strength members protect the
optical fibers. The cable is completed with a LSZH jacket.
Repeatability: ≤0.3dB
Compatibility: ≤0.3dB
Insertion times:>1000
Working temperature: -25℃~70℃.
Order Information and Characteristics of Optical Cables
Tensile Strength
Cable Type
Cable Size (mm)
Weight (kg/km)
Crush Resistance
Patch Cords
Bending Radius
Long/ShortTerm
Long/ShortTerm
Static/Dynamic
(N)
(N/100 mm)
(mm)
Storage, operating
Temperature (°C)
NTFJ
A
C
B
D
E
F
(2.0±0.1)×(3.0±0.1)
7.5
40/80
500/1000
15/30
-20~+60
AB : LC.SC.FC. ST.MTRJ.E2000.MPO/MTP.
(2.0±0.1)×(3.0±0.1)
7.5
40/80
500/1000
15/30
-20~+60
NT-GJXFH-2B6a2n
(2.0±0.1)×(3.0±0.1)
7.5
40/80
500/1000
15/30
-20~+60
CD: Blank:PC
U:UPC
A: APC.
Characteristics
Simple structure, light weight, high tensile strength and metal free
Novel groove design, easily strip and splice, simplified installation and maintenance
Low smoke, zero halogen and flame retardant sheath, environment-friendly, good safety.
G657 fiber information
E : S: Singlemode
Blank:OM1
O:OM2
Q:OM3
LO:OM4
F : 01.02.03.04...M
G : SX:Duplex
DX:Duplex
H : Blank:OD2.0mm
T: OD3.0mm
Pigtail
NTFP
A
C
E
F
G
OPTICAL FIBER
Mode field diameter (1310nm):8.6μm±9.5μm.
Cladding diameter:125μm±0.7μm.
Coating diameter:245μm±7μm.
Cut off wavelength of cabled fiber ( cc):≤1260μm.
Attenuation at 1310nm:≤0.35dB/km.
Attenuation at 1550nm:≤0.21dB/km.
Bending loss at 1550nm (100 turns, 30mm radius):≤0.05dB.
Dispersion in the range 1288 to 1339nm:≤3.5ps/(nm km).
Dispersion at 1550nm:≤18ps/(nm km).
Dispersion slope at zero dispersion wavelength:≤0.092ps/(nm2 km).
H
PATCH PANELS
NT-GJXFH-1B6a2
NT-GJXFH-2B6a2n
G
H
A : LC.SC.FC. ST.MTRJ.E2000.MPO/MTP.
Standards
Comply with standard YD/T1997-2009
Delivery Length
Standard Reel Length: 2000m; Other lengths available on request.
C : Blank:PC
U:UPC
A: APC.
E : : Singlemode
Blank:OM1
O:OM2
Q:OM3
LO:OM4
CABINETS
F : 01.02.03.04...M
G : SX:Duplex
DX:Duplex
page 103
page 104
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
OPTIC FIBER ADAPTER
STRUCTURE CABLING
OPTIC FIBER DISTRIBUTION BOX
SC fast connector
FC/APC One-piece
FC/PC Big D
FC/PC Small D
Characteristics
Item
SC/PC SM
SC/APC Split--body
Performance
Insertion loss
Average≤0.2dB, MAX≤0.4dB
Return ross
PC:≥40dB,APC≥55dB
One-time Assembly Rate
≥97%
Assembly Repeatability
More than 5 times
Average Assembly Time
≤3 minutes
Life-time
≥30years
Tensile Strength
≥30N (2x3 Bow-type drop cable)
Operation Temperature
-40~+75℃
Ordering information
NTFCPPSC _
MODULES
ST/PC
FACE PLATE
Adapter
FC/PC Split-body
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
U: UPC
A: APC
SC/PC MM
Mechanical Splice
Characteristics
Item
SC/APC Duplex SM
SC/PC Duplex MM
LC/APC Duplex SM
Φ0.25 mm &Φ0.90 mm Fiber
Optical fiber diameter
125μm ( 652 & 657 )
Tight buffer diameter (μm)
250μm
Fiber mode
Single & multi mode
Operation time
About 10s(no fiber cut)
Average Insert loss
≤0.15dB(1310nm & 1550nm)
Return loss
≤-40dB
Fastening strength of naked fiber
>5 N
Fastening strength of naked fiber holder
>8 N
Using temperature
-40~+75℃
Repeatability(10 times)
△ IL ≤ 0.2dB △ RL ≤ 5dB
PATCH PANELS
SC/PC Duplex SM
Technical Parameters
Applicable for
LC/PC Duplex SM
LC/PC Duplex MM
FC-SC/PC
FC-SC/PC with ferrule
OPTICAL FIBER
Shelf optical cable terminal box
Optical termination box has the following features
The splice of optical cable or fiber can be finished individually
in the terminal box.
It may inlet and outlet not only from optical cable to optical
cable but also form optical cable to pigtail.
The capacity of terminal box may vary from 8 cores.
There is reliable optical cable fixing and ground protection
device and sealing device.
Order Information
PART Number
Parameter
page 105
Description
8 ports SC simplex adapter shelf optical cable terminal box
CABINETS
Insertion loss:≤0.2dB; Repeatability: ≤0.1dB; Insertion times: >1000.
Working temperature: -25℃~70℃; Store temperature:-40℃~85℃.
NTTB01-08-SC
NTTB02-08-CS
8 ports SC duplex adapter shelf optical cable terminal box
NTTB01-08-ST
8 ports ST simplex adapter shelf optical cable terminal box
page 106
STRUCTURE CABLING
OPTIC FIBER DISTRIBUTION BOX
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
STRUCTURE CABLING
OPTIC FIBER DISTRIBUTION BOX
Outdoors Fusion Splice Box
Product description:
Product description:
Order Information
PART Number
Description
NTFPPSC24PSX
24 Port SC Simplex Adaptors Optic Fiber Distribution Box
NTFPPSC12PSX
12 Port SC Duplex Adaptors Optic Fiber Distribution Box
NTFPPST24PSX
24 Port ST simplex Adaptors Optic Fiber Distribution Box
FACE PLATE
19" cabinet optic fiber distribution box
It can be mounted on 19" cabinet, optic splicing tray in it,
Drawer design, made of armor plate of high quality.
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
The casing of high strength insulation material has
excellent mechanical properties.
Perfect sealing measures.
This product can be re-opened after sealing,
replacement of sealing materials can be reused after.
Application
MODULES
Overhead installation.
Pipe Installation.
Direct buried installation.
Parameter
19" cabinet optic fiber distribution box
Product description:
Order Information
PART Number
Description
NTFDB24P
ODF 1RU 24 Port SC Duplex Adapter Panels
NTFDB48P
ODF 1RU 48 Port SC Duplex Adapter Panels
NTFDB96P
ODF 1RU 96 Port SC Duplex Adapter Panels
*Other Fiber Adapter Panels available upon request.
PATCH PANELS
It can be mounted on 19" cabinet, optic splicing tray in it,
Drawer design, made of armor plate of high quality.
Removable Fiber Adapter Panels
Hinged acrylic front door for a higher dust protection.
Dimension(MM):Φ85X 330
Weight(Kg):1.5
Cable diameter(MM):Ф7-Ф19
Cable entry ports:two ports in and two ports out
Max Capacity of Fiber Splice:6 (single)
Max Capacity of Splice Tray:2
Max Capacity:12 (single)
Structure of cable entry port:heat-shrinkable sealing structure
Sealing structure:silicon gum material.
Outdoors Fusion Splice Box
Product description:
The casing of high strength insulation material has excellent
mechanical properties.
Perfect sealing measures.
This product can be re-opened after sealing, replacement of
sealing materials can be reused after.
Application
Overhead installation.
Pipe Installation.
OPTICAL FIBER
19" cabinet optic fiber distribution box
Parameter
Product description:
It can be mounted on 19" cabinet, optic splicing tray in it,
Drawer design, made of armor plate of high quality.
Order Information
PART Number
Description
NTFPPMPOLC
MPO-LC Type Patch Panel
Dimension (MM):390X 180 X 88.
Weight (Kg):4.2.
Cable diameter (MM):Ф5-Ф14.
Cable entry ports:Four ports in and Four ports out.
Max Capacity of Fiber Splice:12 (single).
Max Capacity of Splice Tray:4.
Max Capacity:48 (single).
Structure of cable entry port:heat-shrinkable sealing structure.
Sealing structure:silicon gum material.
CABINETS
page 107
page 108
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
STRUCTURE CABLING
CABINETS
FACE PLATE
MODULES
PATCH PANELS
VE cabinet
601S cabinet
118 — 122
603 cabinet
123 — 125
PE cabinet
126 — 130
TE cabinet
131 — 132
SE wall box
133 — 135
EW wall box
136 — 138
SA wall box
139 — 140
SB wall box
141 — 142
SQ wall box
143 — 144
VA wall box
145 — 147
148 — 149
150 — 151
Cabinets fitting
152 — 168
CABINETS
605 data racks
606 open racks
OPTICAL FIBER
page 111
113 — 117
page 112
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
CABINET
ORION SERVER CABINETS
Orion Cabinets
FACE PLATE
Feature
Standard
Material
SPCC Cold Rolled Steel;
19” rails: 2.0mm;
Casters tray:2.0mm;
others:1.2mm.
Color
VE: RAL7035.
VE: RAL7021.
LoadingCapacity
Static loading:1300KG.
MODULES
Packaging: Orion Cabinets could be shipped in disassembled
packing, saving transportation and storage cost.
.
New appearance design :Side door: split into 2 parts, lockable
with square locks.
.
Front and rear door: pluggable front door and rear doors, with
external hinges.
.
Casters: built-in installation design.
.
Frame: duplex profile frames with patent, could be connected
by 8 pieces of screws.
.
Front and rear doors: "two points" locking design making
doors and frames closed tighter, turning angle up to 180
degrees.
.
Cable entries on top and bottom: sliding and adjustable cable
entries on top and bottom, edges of cable entries are with the
design to prevent wires from scratching.
.
Fan unit: installed from top outside of cabinet, easy to install
and maintain.
.
Mounting rails: installation positions of mounting rails could
be adjusted quickly. Dedicated channel alignment reserved in
internal of cabinets.
.
Cabinet structure: patented structure.
.
Maximum loading capacity: 1300kg.
.
Comply with ANSI/EIA RS-310-D、
IEC60297-2、DIN41494;PART1;
DIN41494;PART7.
PATCH PANELS
Multi-function cable manger is
available in the rear.
Safty Warning label.
Cable Entrence in the bottom is
ajustable.
Cable manager with cover is available
for 800mm width cabinet .
CABINETS
19” zinc coated profile with scale.
OPTICAL FIBER
page 113
19” mounting angle with sacle enables
users to precisely locate profile.
page 114
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
CABINET
ORION SERVER CABINETS
CABINET
ORION SERVER CABINETS
FACE PLATE
MainPart
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
OrderingInformation
S/N
Specification
Qty
Material
SurfaceFinish
Remark
PartNumber.
1
Rear door
1
----
----
See front&rear door type
NTSCO■■26U66
2
Side panel
4
SPCC t1.2
Powder coated
NTSCO■■42U66
3
19” rails
4
T2.0
zinc-plated
NTSCO■■26U68
4
Front beam
2
SPCC t1.5
Powder coated
NTSCO■■42U68
Width(mm)
Depth(D)(mm)
Capacity(U)
Height(H)(mm)
26
1200
CKDpackingparts
600
600
42
2000
26
1200
42
2000
3
800
5
Top cover
1
SPCC t1.2
Powder coated
NTSCO■■42U61
1000
42
2000
6
Side frame
2
SPCC t1.2
Powder coated
NTSCO■■42U88
800
42
2000
7
Cable management slot
2
SPCC t1.0
Powder coated
1000
42
2000
8
Front door
1
----
----
See front&rear door type
9
Mounting spacer
4
T2.0
zinc-plated
Only used for 800 width cabinet
Bottom
1
SPCC t1.0
Powder coated
11
Caster tray
2
SPCC t2.0
Powder coated
12
2” heavy duty castor
4
----
----
----
hardwarekitswithcabinet:
A
M12 adjustable feet
4
Steel
zinc-plated
Height:100MM
B
M6 screw& nuts
20/40
Steel
zinc-plated
40pcs for over 33U
C
Quiet fan assembly kit
1
Steel
Powder coated
4 fans, 115V, 125 CFM/Min
D
Grounding kit
1
Copper
----
4 ground wires, 1 ground bar
800
NTSCO■■42U81
4
MODULES
10
Only used for 800 width cabinet
Front&Rear Door (type 1)
Tempered glass door
long-handled lock
180°Maximum opening angle;
Material: Sheet steel 4MM
safety glass
Surface Finish: Powder coated
Colors: RAL7035; RAL7021
Front&Rear Door (type 4)
Sheet steel door with hexagon
hole. Long-handled lock;
180°Maximum opening angle;
Material: Sheet steel
Surface Finish: Powder coated
Colors: RAL7035; RAL7021
Front&Rear Door (type 5)
High-density vented door;
Slotted surface(SW7 hexagon)
Air inlet opening>67%;
long-handled lock;
180°Maximum opening angle;
Material: Sheet steel
Surface Finish: Powder coated
Color: RAL7035; RAL7021
Front&Rear Door (type 6)
High density double opened damper
(SW7 hexagon) Air inlet opening>67%;
long-handled lock;
180°Maximum opening angle;
Material: Sheet steel
Surface Finish: Powder coated
Color: RAL7035; RAL7021
Additionalfanunitsavailableuponrequest.
PATCH PANELS
DefinitionofCode
NTSCO
U
Cabinetdepth:(MM):6=600;8=800;1=1000;
12=1200
Cabinetwidth:(MM):6=600;8=800
Cabinetcapacity(U): 26, 42.
Definitionoffrontdoor:
1: Tempered glass door with striped hole (type 1).
4: Sheet steel door with hexagon hole(type 4).
5: High-density vented door (type 5).
6: High density double opened door with damper (type 6).
OPTICAL FIBER
Definitionofreardoor:
1: Tempered glass door with striped hole (type 1).
4: Sheet steel door with hexagon hole (type 4).
5: High-density vented door (type 5).
6:High density double opened door with damper (type 6).
*Special orders available upon request
CABINETS
page 115
page 116
CABINET
ORION SERVER CABINETS
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Spark Network Cabinet
FACE PLATE
Assembling Draft
Standard
Comply with ANSI/EIA RS-310-D、
IEC60297-2, DIN41494;
PART1;DIN41494;PART7
Material
SPCC Cold Rolled Steel;
19” rails:2.0mm, side panel:1.0mm
others: 1.2mm
MODULES
Color
RAL7035
RAL9004
LoadingCapacity
Static loading: 800KG
Feature
PATCH PANELS
CKDPacking
Exquisite design with precise dimension
and craftsmanship.
Several styles of front and rear doors options
available.
Adjustable feet and heavy duty castors are
available simultaneously.
Cable entry on the top cover and bottom
panel with adjustable sizes.
Optional installation of plinth to enable
cabinets fixation, under-base cable
entry/ventilation.
Efficient and reliable cabinet connection
by baying kit.
Removable side panels to ease the maintenance.
OPTICAL FIBER
CABINETS
page 117
page 118
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
CABINET
SPARK NETWORK CABINETS
CABINET
SPARK NETWORK CABINETS
S/N
Specification
Qty
Material
SurfaceFinish
Remark
1
Rear door
1
----
----
See front&rear door type
2
Side panel
2
SPCC t1.0
Powder coated
Small round lock
3
19” rails
4
SPCC t2.0
zinc-plated
4
Mounting angle
4/6
SPCC t1.2
Powder coated
5
Top cover
1
SPCC t1.2
Powder coated
6
Frame
2
SPCC t1.2
Powder coated
8
9
Cable management siot
Front door
Mounting spacer
2
1
8/12
6pcs for over 33U
---SPCC t1.2
Only used for 800 width cabinet
----
See front&rear door type
Powder coated
Only used for 800 width cabinet :
6pcs for over 33U
SPCC t1.2
Powder coated
11
cable entry panel
4
SPCC t1.2
Powder coated
12
2” heavy duty castor
4
----
----
----
B
C
D
E
M12 adjustable feet
M6 screw& nuts
Capacity
(U)
Height(H)
(mm)
NTNCS■■15U66
15
800
NTNCS■■20U66
20
1022
NTNCS■■24U66
24
1200
NTNCS■■29U66
29
1422
NTNCS■■33U66
33
1600
NTNCS■■38U66
38
1822
NTNCS■■42U66
42
2000
NTNCS■■47U66
47
2222
NTNCS■■15U68
15
800
NTNCS■■20U68
20
1022
NTNCS■■24U68
24
1200
29
1422
NTNCS■■33U68
33
1600
NTNCS■■38U68
38
1822
NTNCS■■42U68
42
2000
NTNCS■■47U68
47
2222
NTNCS■■38U69
38
1822
42
2000
NTNCS■■47U69
47
2222
NTNCS■■38U61
38
1822
CKD
packingparts
3
600
800
4
20/40
Trox tooling
1
Quiet fan assembly kit
1
Grounding kit
Depth(D)
(mm)
NTNCS■■29U68
hardware kits with cabinet:
A
Width
(mm)
MODULES
1
PartNumber.
600
Powder coated
SPCC t1.0
Bottom
10
FACE PLATE
OrderingInformation
Main Part
7
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
1
Height:100MM
Zinc-plated
Steel
Zinc-plated
Steel
40pcs for over 33U
----
Zinc-plated
Steel
Steel
4 fans, 115V, 125 CFM/Min
Powder coated
----
Copper
4 ground wires, 1 ground bar
Additionalfanunitsavailableuponrequest.
900
NTNCS■■42U69
3
42
2000
NTNCS■■47U61
1000
47
2222
NTNCS■■38U86
38
1822
42
2000
NTNCS■■47U86
47
2222
NTNCS■■38U88
38
1822
42
2000
47
2222
38
1822
600
NTNCS■■42U86
NTNCS■■42U88
800
NTNCS■■47U88
Right-angled frame enables
users to easily place the logo.
Easily connected and removed
earth cable available.
800
DefinitionofCode
NTNCS
U
2000
47
2222
NTNCS■■38U81
38
1822
42
2000
47
2222
NTNCS■■47U81
900
1000
OPTICAL FIBER
42
NTNCS■■47U89
NTNCS■■42U81
Cabinetdepth:(MM):6=600;8=800;1=1000;
12=1200
4
NTNCS■■38U89
NTNCS■■42U89
PATCH PANELS
NTNCS■■42U61
Cabinetwidth:(MM):6=600;8=800
Cabinetcapacity(U): 15, 20, 24, 29, 33, 38, 42, 47.
Definitionofreardoor:
0-Tempered glass door (type 0)
1-Tempered glass door with striped hole (type 1)
2-Tempered glass door with hexagon hole (type 2)
3- Sheet steel door (type 3)
4-Sheet steel door with hexagon hole (type 4)
5-High-density vented door (type 5)
page 119
CABINETS
*Special orders available upon request
Definitionoffrontdoor:
0-Tempered glass door (type 0)
1-Tempered glass door with striped hole (type 1)
2-Tempered glass door with hexagon hole (type 2)
3- Sheet steel door (type 3)
4-Sheet steel door with hexagon hole (type 4)
5-High-density vented door (type 5)
page 120
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
CABINET
SPARK NETWORK CABINETS
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
CABINET
SPARK NETWORK CABINETS
FACE PLATE
Front & rear door (type 1)
Tempered glass door with striped hole.
Gray decoration bar;
Small lock;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material:
Sheet steel
5MM safety glass
Surface Finish: Powder coated
Color: RAL7035; RAL9004
Front & rear door (type 2)
Tempered glass door with net hole.
Gray decoration bar;
Lock with comfort handle;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material:
Sheet steel
5MM safety glass
Surface Finish: Powder coated
Color: RAL7035; RAL9004
Front & rear door (type 3)
Sheet steel door.
Small lock;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material:
Sheet steel
Surface Finish: Powder coated
Color: RAL7035; RAL9004
Front & rear door (type 4)
Sheet steel door with hexagon hole.
Small lock;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material:
Sheet steel
Surface Finish: Powder coated
Color: RAL7035; RAL9004
Front & rear door (type 5)
High-density vented door;
Slotted surface (SW7 hexagon) Air
inlet opening>60%;
Lock with comfort handle;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material: Sheet steel
Surface Finish: Powder coated
Color: RAL7035; RAL9004
CKD Packing
MODULES
Front & rear door(type 0)
Tempered glass door.
Small lock;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material:
Sheet steel
5MM safety glass
Surface Finish: Powder coated
Color: RAL7035;RAL9004
PATCH PANELS
OPTICAL FIBER
CABINETS
page 121
page 122
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
CABINET
SERVER CABINETS
Server Cabinets
FACE PLATE
Feature
Standard
Comply with ANSI/EIA RS-310-D、
IEC60297-2、DIN41494; PART1;
DIN41494; PART7 .
Material
SPCC Cold Rolled Steel;
19” rails:2.0mm, frame: 1.5mm,
others: 1.2mm.
Color
RAL7035.
RAL9004.
MODULES
Reticular high-density vented front door (patent) & rear door
for protection, ventilation and reliable operation.
Exquisite image (patent) with precise dimension and
craftsmanship.
Lockable cable entry on top cover and bottom panel with
adjustable sizes.
Optional plinth enables cabinets to stay in a fixed position
while meeting requirements of under-base wiring/ventilation
and rat prevention.
Strong cabinet connection by baying kit (patent).
Lock with handle.
LoadingCapacity
Static loading:1000KG.
PATCH PANELS
MainPart
S/N
Specification
Qty
Material
SurfaceFinish
1
Side panel
2
SPCC t1.2
Powder coated
Rear door
1
SPCC t1.2
Powder coated
Frame
1
SPCC t1.5
Powder coated
4
Top cover
1
SPCC t1.2
Powder coated
5
19” rails
4
SPCC t2.0
Powder coated
OPTICAL FIBER
2
3
Remark
Double high-density vented
----
6
Front door
1
SPCC t1.2
Powder coated
High-density vented
7
Mounting plate
2
SPCC t1.5
Powder coated
----
8
2” heavy duty castor
4
----
----
----
A
M12 adjustable feet
4
----
v
----
Steel
Color zinc
40pcs for over 33U
B
M6 screw& nuts
20
C
Trox tooling
1
Steel
Color zinc
----
C
Quiet fan assembly kit
1
Steel
Powder coated
4 fans, 115V, 125 CFM/Min
D
Grounding kit
1
Copper
----
4 ground wires, 1 ground bar
The 600mm width cabinet can be changed to the 800mm width one, only need to put the connecting panel and 2 cable management slots.
Support 19” EIA equipment. Additional fan units available upon request.
CABINETS
page 123
page 124
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
CABINET
SERVER CABINETS
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Network Cabinets
FACE PLATE
OrderingInformation
ModelNo.
Capacity(U)
Height(H)(mm)
PackingdimensionW*D*H
NTSC33U66
33
1600
670*670*1700
NTSC38U66
38
1800
670*670*1900
Width(mm)
Depth(D)(mm)
600
NTSC42U66
42
2000
670*670*2100
NTSC47U66
47
2200
670*670*2300
NTSC33U68
33
1600
670*870*1700
NTSC38U68
38
1800
670*870*1900
NTSC42U68
42
2000
670*870*2100
800
600
47
2200
670*870*2300
NTSC33U69
33
1600
670*970*1700
NTSC38U69
38
1800
670*970*1900
NTSC42U69
42
2000
670*970*2100
NTSC47U69
47
2200
670*970*2300
NTSC42U61
42
2000
670*1070*2100
2200
670*1070*2300
900
1000
NTSC47U61
47
NTSC42U86
42
600
2000
870*670*2100
NTSC42U88
42
800
2000
870*870*2100
NTSC42U89
42
900
2000
870*970*2100
NTSC42U81
42
1000
2000
870*1070*2100
Comply with ANSI/EIA RS-310-D,
IEC60297-2, DIN41494; PART1;
DIN41494; PART7 .
Material
SPCC Cold Rolled Steel;
19” rails:2.0mm, others: 1.2mm.
Color
MODULES
NTSC47U68
Standard
RAL7035.
RAL9004.
LoadingCapacity
Static loading:800KG.
800
Note: Cabinet should not in flat packing.
PATCH PANELS
DefaultFrontandRearDoors
Rear Door (type 6)
High density double opened damper
(SW7 hexagon) Air inlet opening>67%;
long-handled lock;
180°Maximum opening angle;
Material: Sheet steel
Surface Finish: Powder coated
Color: RAL7035; RAL7021
OPTICAL FIBER
Front Door (type 5)
High-density vented door;
Slotted surface(SW7 hexagon)
Air inlet opening>67%;
long-handled lock;
180°Maximum opening angle;
Material: Sheet steel
Surface Finish: Powder coated
Color: RAL7035; RAL7021
CABINETS
page 125
page 126
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
CABINET
NETWORK CABINETS
CABINET
NETWORK CABINETS
Capacity(U)
Height(H)(mm)
NTNC15U66
15
800
NTNC20U66
20
1000
NTNC24U66
24
1200
NTNC29U66
29
1400
NTNC33U66
33
1600
NTNC38U66
38
1800
NTNC42U66
42
2000
NTNC47U66
47
2200
NTNC15U68
15
800
NTNC20U68
20
1000
NTNC24U68
24
1200
29
1400
33
1600
NTNC38U68
38
1800
NTNC42U68
42
2000
NTNC47U68
47
2200
NTNC38U69
38
1800
42
2000
NTNC47U69
47
2200
NTNC38U61
38
1800
PartNumber.
Width(mm)
3
600
800
NTNC33U68
900
NTNC42U69
3
1000
2000
47
2200
NTNC38U86
38
1800
42
2000
NTNC47U86
47
2200
NTNC38U88
38
1800
42
2000
47
2200
38
1800
600
NTNC42U86
800
NTNC42U88
NTNC47U88
NTNC38U89
NTNC42U89
Material
Front door
1
----
2
Frame
2
3
Side frame
Remark
Powder coated
See next page
SPCC t1.2
Powder coated
----
2
SPCC t1.2
Powder coated
----
4
900
42
2000
NTNC47U89
47
2200
NTNC38U81
38
1800
42
2000
47
2200
NTNC42U81
1000
NTNC47U81
OPTICAL FIBER
1
SurfaceFinish
800
PATCH PANELS
42
NTNC47U61
NTNC42U61
Qty
CKDpackingparts
600
NTNC29U68
MainPart
Depth(D)(mm)
MODULES
Flat packing and patent frame, packing time is less than
20 minutes,
Exquisite design with precise dimension and craftsmanship.
Several styles of front and rear door options available.
Adjustable feet and heavy duty castors are available
simultaneously.
Cable entry on the top cover and bottom panel with
adjustable sizes .
Optional installation of plinth to enable cabinets fixation,
under-base cable entry/ventilation.
Efficient and reliable cabinet connection by baying kit.
Removable side panels to ease the maintenance.
Specification
FACE PLATE
OrderingInformation
Feature
S/N
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Packing dimensions: Carton width=cabinet width+40mm, Carton depth=cabinet depth+40mm, Carton height=cabinet hight+90mm
4
Side panel
2
SPCC t1.2
Powder coated
≥ 1000 width cabinets need 4 panels
5
Rear door
1
----
Powder coated
See next page
6
Top cover
1
SPCC t1.2
Powder coated
----
7
19” rails
4
SPCC t2.0
Powder coated
----
8
Bottom
1
SPCC t1.2
Powder coated
----
9
2” heavy duty castor
4
----
----
----
A
M12 adjustable feet
4
----
v
----
B
M6 screw& nuts
20
Steel
Color zinc
40pcs for over 33U
C
Trox tooling
1
Steel
Color zinc
----
D
Quiet fan assembly kit
1
Steel
Powder coated
4 fans, 115V, 125 CFM/Min
F
Grounding kit
1
Copper
----
4 ground wires, 1 ground bar
Front door (type 0)
Tempered glass door.
Small lock;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material:
Sheet steel
5MM safety glass
Surface Finish: Powder coated
Color: RAL7035;RAL9004
Rear door (type 3)
Sheet steel door.
Small lock;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material:
Sheet steel
Surface Finish: Powder coated
Color: RAL7035; RAL9004
CABINETS
The 600mm width cabinet can be changed to the 800mm width one, only need to put the connecting panel and 2 cable management slots.
Support 19” EIA equipment. Additional fan units available upon request.
127
page
page 128
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
CABINET
DOORS FOR NETWORK CABINETS
Shelf
Plinth
M6 Screws & nets
PDU
Fan units
PATCH PANELS
Front & rear door (type 3)
Sheet steel door.
Small lock;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material:
Sheet steel
Surface Finish: Powder coated
Color: RAL7035; RAL9004
Additionalaccessoriesforthecabinets
MODULES
Front & rear door (type 2)
Tempered glass door with net hole.
Gray decoration bar;
Lock with comfort handle;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material:
Sheet steel
5MM safety glass
Surface Finish: Powder coated
Color: RAL7035; RAL9004
Front & rear door (type 1)
Tempered glass door with striped hole.
Gray decoration bar;
Small lock;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material:
Sheet steel
5MM safety glass
Surface Finish: Powder coated
Color: RAL7035; RAL9004
CABINET
NETWORK CABINETS
FACE PLATE
Front & rear door (type 0)
Tempered glass door.
Small lock;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material:
Sheet steel
5MM safety glass
Surface Finish: Powder coated
Color: RAL7035;RAL9004
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
AssemblingDraft
Attention
Please remove front/back door
and side plane from the frame
prior to unpacking
Front & rear door (type 5)
High-density vented door;
Slotted surface (SW7 hexagon) Air
inlet opening>60%;
Lock with comfort handle;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material: Sheet steel
Surface Finish: Powder coated
Color: RAL7035; RAL9004
1A. Assemble mounting rails (width
600mm). (Screw M6x12 & nuts).
OPTICAL FIBER
Front & rear door (type 4)
Sheet steel door with hexagon hole.
Small lock;
Reversible right or left handed doors;
Turning angle is over 180 degrees;
Material:
Sheet steel
Surface Finish: Powder coated
Color: RAL7035; RAL9004
3. Assemble top cover, bottom panel,
adjustable feet and castor feet (screw M5x10).
2A. Assemble frames (width
600mm). (Screw M6x12 & nuts).
1B. Assemble mounting
rails and spacers (width 800mm).
(Screw M6x12 & nuts).
page 129
4. Assemble front/rear
door and side panels.
CABINETS
2B. Assemble frames (width 800mm)
(screw M5x10).
page 130
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
WALLMOUNT CABINET
START DOUBLE SECTION
Star Wallmount Cabinet
FACE PLATE
Feature
Standard
Comply with ANSI/EIA RS-310-D,
IEC60297-2, DIN41494, PART1,
DIN41494, PART7
Material
SPCC Cold Rolled Steel;
Thickness: 19” rails: 1.2mm,
side panel 1.0mm, others: 1.2mm
Color
RAL7035
RAL9004
Loading Capacity
Static loading: Up to 95 KG
MODULES
Double -section wallmount cabinet.
Tempered glass front door with 180° turning radius
rotatable key lock.
Removable side and rear panels for quick installation of
equipment.
Adjustable front and rear mounting posts conform to
different equipment depth requirements. Dual
mounting post with #12-24 threaded holes and square
holes for cage nuts.
Ventilated door design for added air flow and cooling.
Cable entry brush panel on the top cover and knock-outs on
the bottom plate.
Provided with 1 fans with UL cord installed. Additional fan
may be provided upon request.
Easy to wall mount back plate.
Available in heights from 6u to 23u.
Fully assembled for quick installation and packaged in a
honeycomb carton. Optional space saving flat
packaging available upon request.
DefinitionofCode
NTDWC
U650
Cabinetcapacity(U): 6, 9, 12, 16, 20, 23
PATCH PANELS
Definitionof frontdoor:
0-Tempered glass door (type 0)
1-Tempered glass door with striped hole (type 1)
2-Tempered glass door with hexagon hole (type 2)
3- Sheet steel door (type 3)
4-Sheet steel door with hexagon hole (type 4)
5-High-density vented door (type 5)
Main Part
S/N
Qty
Material
Surface Finish
Remark
Front door
1
5MM toughed glass
door/ SPCCt1.2
Powder coated
----
Specification
1
2
Side panel
2
SPCC t1.0
Powder coated
----
3
Front frame
1
SPCC t1.2
Powder coated
----
4
Back frame
1
SPCC t1.2
Powder coated
-------
5
19 '' rails
A
M6 screw& nuts
SPCC t1.2
Powder coated
Steel
Color zinc
----
1
Steel
Black
----
OPTICAL FIBER
Trox tooling
B
4
10
Specification
Model N o.
RU
Width (mm)
Depth(D)(mm)
Height(H)(mm)
Static Loading Capacity (kg)
NTDWC■6U650
6
600
650
370
70
NTDWC■9U650
9
600
650
500
70
NTDWC■12U650
12
600
650
635
75
NTDWC■16U650
16
600
650
770
80
NTDWC■20U650
20
600
650
900
90
NTDWC■23U650
23
600
650
1080
95
CABINETS
page 141
page 142
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
WALLMOUNT CABINET
START SINGLE SECTION
Star Wallmount Cabinet
FACE PLATE
Feature
Standard
Material
SPCC Cold Rolled Steel;
Thickness: 19” rails: 1.2mm,
others: 1.0mm
Color
RAL7035
RAL9004
Loading Capacity
Static loading: Up to 115 KG
MODULES
Double -section wallmount cabinet.
Tempered glass front door with 180° turning radius
rotatable key lock.
Removable side and rear panels for quick installation of
equipment.
Adjustable front and rear mounting posts conform to
different equipment depth requirements. Dual
mounting post with #12-24 threaded holes and square
holes for cage nuts.
Ventilated door design for added air flow and cooling.
Cable entry brush panel on the top cover and knock-outs on
the bottom plate.
Provided with 1 fans with UL cord installed. Additional fan
may be provided upon request.
Easy to wall mount back plate.
Available in heights from 6u to 23u.
Fully assembled for quick installation and packaged in a
honeycomb carton. Optional space saving flat
packaging available upon request.
Comply with ANSI/EIA RS-310-D,
IEC60297-2, DIN41494, PART1;
DIN41494, PART7
DefinitionofCode
NTFWC
U600
Cabinetcapacity(U): 6, 9, 12, 16, 20, 23
Definitionoffrontdoor:
0-Tempered glass door (type 0)
PATCH PANELS
Main Part
S/N
Specification
Qty
Material
Surface Finish
Remark
1
Frame
1
SPCC t1.0
Powder coated
----
2
Side panel
2
SPCC t1.0
Powder coated
----
3
Front door
1
5MM toughed glass
----
----
4
19 '' rails
4
SPCC t1.2
Powder coated
----
A
M6 screw& nuts
10
Steel
Color zinc
----
B
Trox tooling
1
Steel
Black
----
OPTICAL FIBER
Specification
Model N o.
RU
Width (mm)
Depth(D)(mm)
Height(H)(mm)
Static Loading Capacity (kg)
NTFWC06U600
6
600
600
370
90
NTFWC09U600
9
600
600
500
90
NTFWC012U600
12
600
600
635
95
NTFWC016U600
16
600
600
770
100
NTFWC020U600
20
600
600
900
110
NTFWC023U600
23
600
600
1080
115
CABINETS
page 143
page 144
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
DATA RACK
GEMINI 4-POST RACK
Gemini 4-post Rack
FACE PLATE
Additional accessories
Standard
Comply with ANSI/EIA RS-310-D,IEC60297-2,
DIN41494, PART1, DIN41494, PART7
Material
SPCC Cold Rolled Steel;
Column:1.5mm, others: 2.0mm
Color
L bracket (upon request)
MODULES
RAL7035
RAL9004
Loading Capacity
Static loading: 250KG
Features
Modular design, easily assemble and disassemble
for low-cost delivery.
Additional accessories available upon request.
Trim plate (upon request)
PATCH PANELS
Fix Shelf (upon request)
Main Part
S/N
Specification
Qty
Material
Surface Finish
Remark
1
Column
4
SPCC t1.5
Powder coated
----
2
Plinth
4
SPCC t1.5
Powder coated
----
3
Support Cross beam
2
SPCC t2.0
Powder coated
----
4
2” heavy duty castor
4
20
Steel
Color zinc
40pcs for over 33U
1
Steel
Black
----
M6 screw& nuts
Trox tooling
B
----
OPTICAL FIBER
A
Specification
RU
Width (mm)
Depth(D)(mm)
Height(H)(mm)
Volume (CBM)
NTFRG4P29USTBK
29
600
600
1422
1420*260*140
NTFRG4P33USTBK
33
600
600
1600
1600*260*140
NTFRG4P38USTBK
38
600
600
1822
1820*260*140
NTFRG4P42USTBK
42
600
600
2000
2000*260*140
NTFRG4P47USTBK
47
600
600
2222
2220*260*140
Model N o.
The packing information is for the flat pack and we suggest to use this flat pack to get significant cost saving.
CABINETS
page 147
page 148
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
DATA RACK
GEMINI 2-POST RACK
Gemini 2-post Rack
FACE PLATE
Feature
Modular design, easily assemble and disassemble for delivery,
low-cost.
Various optional accessories according to requirements(cable
management slot, removable working panel, etc.).
Standard
Comply with ANSI/EIA RS-310-D, IEC60297-2,
DIN41494, PART1, DIN41494, PART7
Additional accessories upon request
Material
SPCC Cold Rolled Steel;
Column: 1.5mm, others: 2.0mm
Color
MODULES
RAL7035
RAL9004
Loading Capacity
Static loading: 150KG
Double Sided Shelf
Solid shelf
PATCH PANELS
Horizontal cable management
Main Part
S/N
Specification
Qty
Material
Surface Finish
Remark
1
Column
2
SPCC t1.5
Powder coated
----
2
Plinth
2
SPCC t2.0
Powder coated
----
3
Support Cross beam
2
SPCC t2.0
Powder coated
----
4
2” heavy duty castor
4
20
Steel
Color zinc
40pcs for over 33U
1
Steel
Black
----
A
M6 screw& nuts
OPTICAL FIBER
Trox tooling
B
----
Specification
RU
Width (mm)
Depth(D)(mm)
Height(H)(mm)
Volume (CBM)
NTFRG2P29USTBK
29
600
600
1422
1420*260*140
NTFRG2P33USTBK
33
600
600
1600
1600*260*140
NTFRG2P38USTBK
38
600
600
1822
1820*260*140
NTFRG2P42USTBK
42
600
600
2000
2000*260*140
NTFRG2P47USTBK
47
600
600
2222
2220*260*140
Model N o.
CABINETS
page 149
page 150
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
CABINETS FITTING
PDU
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
CABINETS FITTING
PDU
Output unit type
FACE PLATE
PDU
Input connector type
AS/NZS 3112
Style
DIN49440
Parameter
10(15A) 250VAC
Parameter
16A 250VAC
IEC320 C13(C19)
Style
Parameter 10(16A) 250VAC
Style
BS1363(90°)
Parameter
13A 250VAC
Name
Master switch
Name
Master overload
Protector & power
indicator
MODULES
Style
Input connector type
Plug style
Bs1363
Plug style
AS/NZS 3112
Parameter
13A 250VAC
Parameter
10/15A 250VAC
Mini circuit
Parameter breaker(1~60A)
Code
LY-A
Name
protective device
PATCH PANELS
IEC60329
Plug style IEC320 C14(C20)
Plug style
DIN49441
Plug style
NEMA 5-15P
Parameter
16/32A 250VAC
Parameter 10(16A) 250VAC
Parameter
16A 250VAC
Parameter
15A 125VAC
BS1363(45°)
Style
NEMA 5-15R
Code
LY-B
13A 250VAC
Parameter
15A 150VAC
Name
protective device
Surge protective device
TUL-LY-A/B
Surge protective device:LY-B
Parameter
250VAC 50/60Hz
Rated load current IR
16A
Max. power PMAX
4000W
Max.Continuous operating voltage UC
320VAC
Measured limiting voltage Ur
<1000V
Nominal discharge current(8/20μs)In
10KA
Voltage protection level Up
<1000V
Response time TA
<25nS
Protection mode
L-N L-PE N-PE
Earth indicator
Yellow LED
Lightning protection
Green LED
Power indicator
Red
Alternative filtration
Highly efficient
Insulation resistance RIS
>100MΩ
Fire resistance
Up to UL 94V-0
Environment temperature
-40~+70℃
Relative humidity
<=95%
LED
Red LED light, when working, means the
Power had Unicom and filtering output.
Green LED light, when disabled, means
the failure ofThe lighting protection circuit.
Yellow LED light, when working,
means the absence of earth wire of the
power supply system, which shall be case
to contact electrician for his professional
and grounding.
CABINETS
Rated voltage
OPTICAL FIBER
page 153
Plug style
Style
Parameter
page 154
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
CABINETS FITTING
TC DIGITAL TEMPERATURE UNIT
Control outprt
Technical parameters
Normal mode
Parmeter modification mode
SET
Check compressor protection time
Display current menu set value
SET…3seconds
Enter into parameter modification
Rst
Check temperature exceeding value
Quit from parameter modification
▲
Temperature upper limits checking
Menu items go backwards
▼
Temperature lower limits checking
10A/277VAC
Higher than 99℃ and lower than 120℃ 。Press any key
to cancel alarm sound,but alarm status remains.
Power supply
220VAC
Key-press function
Item
Function
Fetting range
Unit
Default
F1
Upper limit
F2~+50
℃
-10
F2
Lower limit
-F40~F1
℃
-20
F3
Temperature calibration
-5~5
℃
0
F4
Compressor protection time
0~9
Min
3
F5
Exceeding temperatuer value
0~50,set value as 0 to cancel alam
℃
15
F6
Exceeding temperature alarm delay time
0~99
Min
20
Safety regulations
Danger:Strictly distinguish the sensor down-lead,power
wire and output relay interface from one another,prohibit
wrong connections or overloading the relay.
All connections should be modified under electricity cut-off.
Warning:Prohibit to use the machine in water or under the
environment of ower damp,high temperature,string
electromagnetism interference ir string corrosion.
Error code
Code
Reason
Status
E1
Memorizer error
Alarm,machine does not work
E2
Sensor error
Alarm.Comressor starts
/stop proportionably
HH
Exceeding temp,
display limit
OPTICAL FIBER
Key-press
10A/277VAC
PATCH PANELS
Key-press function
Wire diagram
Alarm:While temp.exceeding valus is not 0.LED blinkingly
displays current temperature when storage temperature is
higher than set temperature upper limip +exceeding temp
value or lower than set lower limit-exceeding temp.walue.
When rumming out of the exceeding temp.limit alarm delay
after electrified.exceeding temp.limit alarm starts with
buzzer sound,and alarm cancel when temperature return
to normal temperature LED blinkingly Display E1 with
buzzer sound when memorizer error;display E2 with
buzzer sound when sensor error,Display HH when temp.
MODULES
When electrify the controller,first check the parameter
setting,if parameter setting is wrong,LED display E1 with
buzzer sound,at this time press Set will restore default
parameter setting.
Advise to reset the parameter.
Parameter modification status
Storage temp.
Restore the parameter setting
Compressor cutput delay
Always on
Sensor
Press set and■or■simultaneously can adjust the current
parameter set value;press set and■simultaneously more
than 1s will increase current parameter set value quickly;
press set and■simultaneously more than 1s will decrease
current parameter set value puickly;
Press rst or no key operation in 30s will save the modified
parameter and retutn to normaltemperature display status.
Flashes
Set
Closed point
Parameter set value
Cool
Co-point
Press set for more than 3s to cnter into parameter modifying
status the last,display the last adjusted menu after electrified
with parameter modifying indicator light on.
Press ▲ or ▼ to go forward or backward the menu item;
press set to display the current.
Compressor cutput
Defrost
Modify parameter set value
Function
Always on
Closed point
Check parameter set value:
Press ▲ and then loosen to display the set upper limit;
Press and then loosen ▼ to display the.
Status
Cool
Co-point
Key operation
Indicator light
Compressor
Front panel
Lndicator light description
Compressor:When the storage temp.ls higher than set
temp.Upper limit,compressor starts,lower than set temp.
Lower limit,compressor stops,When sensor errir,
compressor works proportionably as on -15 minutes off-30
minutes.After electrified or compressor stops.Compressor
restart-up is allowed after running out of compressor
protection time.
19”installation
Simple structure, easy installation;
Easy cabling & operation;
Disturbing resistance、reliable running;
2-way output (IEC320 C13 and NEMA 5-15R).
Power supply:220VAC+10%/-15%,50/60Hz.
Temperature measuring range:-50℃ ~99℃.
Resoluton:1℃.
Refrigeration output contact capacity:10A/277VAC.
Senssor error delay time:1min.
Safe level:1P65.
Operation humidity:20~85%(no condensate).
Power consumption:≤3W.
Temperature controling range:-40℃ ~50℃.
Accuracy:-50℃ ~70℃,±1℃,±1℃at others can
drive single phase compressor≦1/2HP.
Sensor:NTC.
OpERATION TEMPERATURE:-30℃ ~75℃.
CABINETS FITTING
TC DIGITAL TEMPERATURE UNIT
FACE PLATE
TC Digital Temperature Unit
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Caution:The power supply should conform to one labeled
on the machine,and ensure the stability of the power voltage.
Sensor down-lead and power should be kept for a proper
distance to avoid possible interferences.
Menu items go forwards
SET+▲
Parameter values increase by degrees
SET+▼
Parameter values decrease by degrees
CABINETS
page 155
page 156
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
CABINETS FITTING
COOLING
CABINETS FITTING
COLLING
FACE PLATE
2/4 Fan Units
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
1U Fan Units
19” standard installation,
1U Switch control fans work.
Parameter
Fan size:120X120X38, cable length: 1.9M
Input frequency: 100~231V/50Hz
Period: -10℃~+50℃
Material: SPCC cold rolled steel
Color: RAL7035
RAL9004
Model No.
Description
Input connector type
NTFAN2UK
2 fans
UK type(BS1363)
Fan size: 120X120X38, cable length: 1.9M
Input frequency: 100~231V/50Hz
Period: -10℃~+50℃
Material: SPCC cold rolled steel
Color: RAL7035
RAL9004
MODULES
Main part:
Parameter
Main part:
Input connector type
2 fans
German type(DIN49441)
Model No.
Description
2 fans
US type(NEMA 5-15P)
NTFAN1U2UK
2 fans
UK type(BS1363)
NTFAN4UK
4 fans
UK type(BS1363)
NTFAN1U2GE
2 fans
German type(DIN49441)
NTFAN4GE
4 fans
German type(DIN49441)
NTFAN1U2US
2 fans
US type(NEMA 5-15P)
NTFAN4US
4 fans
US type(NEMA 5-15P)
NTFAN1U3UK
3 fans
UK type(BS1363)
NTFAN1U3GE
3 fans
German type(DIN49441)
NTFAN1U3US
3 fans
US type(NEMA 5-15P)
NTFAN1U4UK
4 fans
UK type(BS1363)
NTFAN1U4GE
4 fans
German type(DIN49441)
NTFAN1U4US
4 fans
US type(NEMA 5-15P)
PATCH PANELS
NTFAN2GE
NTFAN2US
2/4 Fan Units With Thermostat
3U Fan Units
Parameter
Main part:
Input connector type
19” standard installation, 3U
Parameter
Fan size: 120X120X38, cable length: 1.9M
Input frequency: 100~231V/50Hz
Period: -10℃~+50℃
Material: SPCC cold rolled steel
Color: RAL7035
RAL9004
OPTICAL FIBER
large setting range: 0℃~+60℃
small size
High switching performance
Fan size:120X120X38, Cable length:1.9m
Input frequency:100~231V/50Hz
Material:SPCC cold rolled steel
Color:RAL7035
RAL9004
Main part:
Model No.
Description
NTFANT2UK
2 fans
UK type(BS1363)
Model No.
Description
NTFANT2GE
2 fans
German type(DIN49441)
NTFAN3U2UK
2 fans
UK type(BS1363)
NTFANT2US
2 fans
US type(NEMA 5-15P)
NTFAN3U2GE
2 fans
German type(DIN49441)
NTFANT4UK
US type(NEMA 5-15P)
Input connector type
4 fans
UK type(BS1363)
NTFAN3U2US
2 fans
NTFANT4GE
4 fans
German type(DIN49441)
NTFAN3U3UK
3 fans
UK type(BS1363)
NTFANT4US
4 fans
US type(NEMA 5-15P)
NTFAN3U3GE
3 fans
German type(DIN49441)
NTFAN3U3US
3 fans
US type(NEMA 5-15P)
CABINETS
page 157
page 158
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
CABINETS FITTING
SHELVES
FACE PLATE
Fixed Shelf
Cooling Fan
For network cabinet, adjust inner temperature
Performance reference.
Parameter
Size:120X120X38
Atmosphere runoff: 50CFM, Noise: 24.9 dB
periode: -10℃~+50℃
Only for Nitrotel cabinet, install from side.
Parameter
Static load capacity: 90 Kg [198Lb]
Material: SPCC 1.2 cold rolled steel
Color: RAL7035
RAL9004
Main part:
Description Input(v)
NTFANU
AC fans
115
Axletree Type
Model No.
Oiliness Axletree
Shelf size MM
MODULES
Main part:
Model No.
CABINETS FITTING
SHELVES
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
Use
Width
Depth
NTFS350
485
350
600MM
NTFS550
485
550
800MM
NTFS620
485
620
900MM
NTFS720
485
720
1000MM cabinet
Solid Shelves
Used for 19 inch network cabinet and rack.
Parameter
Material: SPCC cold rolled steel.
Color: RAL7035
RAL9004
PATCH PANELS
Vented Shelves
Used for 19 inch network cabinet and rack.
Main part:
Parameter
Model No.
Description
Capacity
NTSS2UX15
2U-15” DP
22Kg.[48Lb]
NTSS2UX18
2U-18” DP
22Kg.[48Lb]
material: SPCC cold rolled steel.
Color: RAL7035
RAL9004
Main part:
Used for 19” open rack, 2U height.
Parameter
material: SPCC cold rolled steel.
Color: RAL7035
RAL9004
Main part:
Model No.
Description
Capacity
NTSSD2U25
2U-25” DP
50Kg.[110Lb]
Description
Capacity
NTVS1UX105
1U-10.5” DP
14Kg.[30Lb]
NTVS1UX12
1U-12” DP
16Kg.[35Lb]
NTVS1UX15
1U-15” DP
23Kg.[50Lb]
NTVS1UX18
1U-18” DP
26Kg.[56Lb]
NTVS2UX105
2U-10.5” DP
16Kg.[35Lb]
NTVS2UX12
2U-12” DP
NTVS2UX15
2U-15” DP
24Kg.[52Lb]
NTVS2UX18
2U-18” DP
25Kg.[54Lb]
OPTICAL FIBER
Double Sided Shelf (2U)
Model No.
18Kg.[39Lb]
CABINETS
page 159
page 160
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
CABINETS FITTING
SHELVES
Used for 19 inch network cabinet.
Keyboard allowed maximum size 4200X200MM.
Keyboard and mouse are individually placed for
convenient operation.
Parameter
L Brackets
Only for SHIP 19” cabinet and wall box, install from side.
Parameter
Static load capacity: 15 Kg [33Lb]
Material: SPCC cold rolled steel.
Color: RAL7035
RAL9004
material: SPCC cold rolled steel.
Color: RAL7035
RAL9004
Ordering information
Main part:
Use
Description
NTMKS1UX18 Keyboard and mouse shelf 600~800MM cabinet
Keyboard and Mouse Drawer (2U)
Model No.
Description
Length
Use
NTLB45
45 type
300
450MM wall box
NTLB66
66 type
450
600MM wall box
NTLB60
60 type
320
600MM cabinet
NTLB80
80 type
520
800MM cabinet
NTLB90
90 type
620
900MM cabinet
NTLB10
10 type
720
1000MM cabinet
MODULES
Model No.
CABINETS FITTING
PANEL/BRACKETS
FACE PLATE
Keyboard With Mouse Panel (1U)
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
PATCH PANELS
Used for 19 inch network cabinet.
Keyboard allowed maximum size 450X200MM.
Keyboard and mouse are individually placed for convenient operation.
Parameter
Material: SPCC cold rolled steel.
Color: BLACK
Blanking Panel
Main part:
Compatible with 19 inch network cabinet, cover the blank
position.
Model No.
Use
NTMKD2X18
800~1000MM cabinet
Sliding Adjustable Shelf (1U)
Parameter
Material: SPCC cold rolled steel.
Color: RAL7035
RAL9004
OPTICAL FIBER
Main part:
Used for 19 inch network cabinet.
Parameter
Static load capacity: 30 Kg [66Lb]
Material: SPCC cold rolled steel
Color:RAL7035
RAL9004
Size MM
Model No.
Description
NT-SBP-1U
1U
482
44
NT-SBP-2U
2U
482
88
NT-SBP-3U
3U
482
132.5
NT-SBP-4U
4U
482
177
Width
Depth
Main part:
Model No.
Description
Shelf size MM
Width
Depth
NTVS1UX14ADJ
350 type
440
350
NTVS1UX26ADJ
550 type
440
550
Use
600~800MM
cabinet
900~1100MM
cabinet
CABINETS
page 161
page 162
STRUCTURE
CABINETS
CABLING
2016 NITROTEL
NITROTELPRODUCT
PRODUCTINFORMATION
INFORMATION
CABINETS FITTING
CABLE MANAGEMENT
CABINETS FITTING
SCREWS & NUTS
Compatible with 19 inch network.
Compatible with 19 inch network, metal cable management
with 4 rings.
Parameter
Parameter
Material: SPCC cold rolled steel.
Color:BLACK
Main part:
Model No.
NTCM1U
10-32 Screws With
Cushion
Cage Nuts and Screws
Parameter
Parameter
Phillips
Phillips /Trox
Color:BLACK
Color:Zinc-plated
Main part:
Main part:
Size MM
Width
Height
482
80
Model No.
NTCM4R1U
MODULES
1U Metal Cable
Management
FACE PLATE
1U Metal Cable
Management With Cover
Material: SPCC cold rolled steel.
Color:BLACK
LAN CABLE &
PATCH CABLE
2016 NITROTEL
NITROTEL
PRODUCT
PRODUCT
INFORMATION
INFORMATION
STRUCTURE
CABINETS
CABLING
Main part:
Size MM
Model No.
Width
Height
Model No.
Packs of
482
68
NTS10-32
100
Compatible with 19 inch network, removable Plastic cable
management with 5 rings.
Compatible with 19 inch network.
Parameter
Parameter
Packs of
50
Phillips
50
M6 Cushion
T30 Trox Tool
Parameter
Parameter
OPTICAL FIBER
1U Cable Management
With Brush
700906002
TYPE
Trox(T30)
PATCH PANELS
1U Plastic Cable
Management
NT
Material: SPCC cold rolled steel and plastic ring.
Color: BLACK ANODIZE.
Main part:
Model No.
NTCMF5R1U
Material: SPCC cold rolled steel+ brush.
Color: BLACK.
Used for M6 screws
Material: ABS
Color: BLACK
Main part:
Size MM
Width
Height
482
68
Model No.
NTBRP1U
Used for M6 screws
Size: φ5.5*33*120
Color:Zinc-plated
Main part:
Size MM
Width
Hole
482
390X30
Model No.
NTCM6
Main part:
Packs of
50
Model No.
NTTT30
Packs of
10
CABINETS
page 163
page 164
STRUCTURE
CABINETS
CABLING
2016 NITROTEL
NITROTELPRODUCT
PRODUCTINFORMATION
INFORMATION
CABINETS FITTING
ACCESSORIES
CABINETS FITTING
PLINTH/DRAWER
FACE PLATE
Earthing Kit
LAN CABLE &
PATCH CABLE
2016 NITROTEL
NITROTEL
PRODUCT
PRODUCT
INFORMATION
INFORMATION
STRUCTURE
CABINETS
CABLING
Plinth
Earthing Kit
Parameter
Only for Nitrotel 19” cabinet,
Static load capacity: 1000 Kg.[2200Lb]
Material: SPCC cold rolled steel
Color::RAL7035
:RAL9004
Main part:
Parameter
Parameter
ROHS complied
14 AWG, 300MM length
ROHS complied
14 AWG, 300MM length
Main part:
Main part:
Shelf size MM
Width
Use
Depth Height
NTPL66S
600
600
100
Spark cabinet
NTPL68S
600
800
100
Spark cabinet
NTPL69S
600
900
100
Spark cabinet
NTPL61S
600
1000
100
Spark cabinet
NTPL86S
800
600
100
Spark cabinet
Packs of
Model No.
Packs of
NTPL88S
800
800
100
Spark cabinet
NTGWK01
2
NTGWK02
2
NTPL66N
600
600
100
Network cabinet
NTPL68N
600
800
100
Network cabinet
NTPL69N
600
900
100
Network cabinet
NTPL61N
600
1000
100
Network cabinet
NTPL86N
800
600
100
Network cabinet
NTPL88N
800
800
100
Network cabinet
Castor
Castor With Braking
PATCH PANELS
Model No.
MODULES
Model No.
Drawer
Parameter
Main part:
Parameter
Parameter
Static load capacity: 250kg
Color: black/ Zinc-plated
Static load capacity: 250kg
Color: black/ Zinc-plated
Main part:
Main part:
Type of Wheel
Packs of
Model No.
Type of Wheel
Packs of
NTCF20
2.0 INCH
4
NTCFB20
2.0 INCH
4
NTCF25
2.5 INCH
4
NTCFB25
2.5 INCH
4
NTCF30
3.0 INCH
4
NTCFB30
3.0 INCH
4
Model No.
OPTICAL FIBER
Used for 19 inch network cabinet and rack.
Static load capacity:35kg
Sliding shelf could elongate to 450MM
material: SPCC cold rolled steel
Color: RAL7035
RAL9004
Model No.
Description
NTDR2UX18
2U-18” DP
NTDR3UX18
3U-18” DP
CABINETS
page 165
page 166
STRUCTURE CABLING NITROTEL PRODUCT INFORMATION
CABINETS FITTING
LOCK
LAN CABLE &
PATCH CABLE
NITROTEL PRODUCT INFORMATION STRUCTURE CABLING
CABINETS FITTING
LOCK
Swing Handle With Combination Lock
Parameter
Product Description
FACE PLATE
Swing Handle with Lock
Product Drawing
Main material and finish: Black PA housing, handle
and knob, white zinc-plated steel cam and support.
Used for Nitrotel cabinet door
Thickness of lock:30MM
Hole size:126X24.5MM
Color: BLACK
Main part:
Model No.
Packs of
NTSHL
MODULES
3
180°
3-Points Lock
Use key to open the lock,without password
Parameter
Used for Nitrotel cabinet door
Thickness of lock:20MM
PATCH PANELS
Hole size:Φ19X16.5MM
Main part:
Model No.
180°
Packs of
NT3PL
50
Enter password to open the lock,open lock with
password instead of key,original password:"0,0,0”
M12 Leveling Feet
OPTICAL FIBER
Parameter
Static load capacity: 250kg
Color: black/ Zinc-plated
Main part:
Model No.
NTLFM12
15°
Height MM
Packs of
100
4
Change the password(it is correct),when knob
indlcates opening position,anti-clickwise rotation
15 degree to change the password
CABINETS
page 167
page 168
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project