Fantom FM625H Commercial Lightweight Upright Vacuum Owner's Manual
Below you will find brief information for FM625H. This lightweight upright vacuum is designed for both household and commercial use. Features include a HEPA filter, multiple attachments (hose, dusting brush, crevice tool, pet hair brush, and air-driven turbo brush), variable suction control, and a convenient cord storage system. The FM625H is easy to assemble and use, and includes instructions for maintaining its filters.
Advertisement
Advertisement
COMMERCIAL LIGHTWEIGHT
UPRIGHT VACUUM
OWNER’S MANUAL
Model FM625H
120V., 60Hz., 12 Amps
FOR HOUSEHOLD OR COMMERCIAL USE
FANTOM
94 Main Mill Street, Door 16
Plattsburgh, NY 12901
Tel.: 1 (800) 275-9251
Model FM625H
ONE (1) YEAR LIMITED WARRANTY
FANTOM warrants this product to be free from defects in material and workmanship for a period of one (1) year from the date of the original purchase, when utilized for normal commercial or household use, subject to the following conditions, exclusions and exceptions.
If your appliance fails to operate properly while in use under normal household conditions within the warranty period, return the complete appliance and accessories, freight prepaid to:
FANTOM, 94 Main Mill Street, Door 16, Plattsburgh, N.Y. 12901
If the appliance is found by FANTOM to be defective in material or workmanship, FANTOM will repair or replace it free of charge. Proof of purchase date and $14.95 to cover the cost of return shipping and handling must be included. *
Non-durable parts including, without limitation, filters, brushes and electrical parts which normally require replacement are specifically excluded from warranty.
The liability of FANTOM is limited solely to the cost of the repair or replacement of the unit at our option. This warranty does not cover normal wear of parts and does not apply to any unit that has been tampered with or used for commercial purposes. This limited warranty does not cover damage caused by misuse, abuse, negligent handling or damage due to faulty packaging or mishandling in transit. This warranty does not cover damage or defects caused by or resulting from damages from shipping or repairs, service or alterations to the product or any of its parts, which have been performed by a repair person not authorized by FANTOM.
This warranty is extended to the original purchaser of the unit and excludes all other legal and/or conventional warranties. The responsibility of FANTOM if any, is limited to the specific obligations expressly assumed by it under the terms of the limited warranty. In no event is FANTOM liable for incidental or consequential damages of any nature whatsoever. Some states do not permit the exclusion or limitation of incidental or consequential damages, so the above may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
*Important: Carefully pack item to avoid damage in shipping. Be sure to include proof of purchase date and to attach tag to item before packing with your name, complete address and phone number with a note giving purchase information, model number and what you believe is the problem with item. We recommend you insure the package (as damage in shipping is not covered by your warranty). Mark the outside of your package “ATTENTION CUSTOMER
SERVICE”. We are constantly striving to improve our products, therefore the specifications contained herein are subject to change without notice.
----------------------------------------------------------------------------------
OWNERSHIP REGISTRATION CARD
Please fill out and mail the product registration card within ten (10) days of purchase. The registration will enable us to contact you in the unlikely event of a product safety notification. By returning this card you acknowledge to have read and understood the instructions for use, and warnings set forth in the accompanying instructions.
RETURN TO EURO-PRO Operating LLC, 94 Main Mill Street, Door 16, Plattsburgh, NY 12901
Appliance model
________________________________________________________________________________________
Date purchased Name of store
_________________________________________________________________________________________
Owner’s name
________________________________________________________________________________________
Address City State Postal code
Printed in China
12
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliance, basic safety precautions should always be observed to reduce the risk of fire, electric shock or injury, including the following:
1.
Read all instructions before using your vacuum.
2.
Use only as described in this manual. Use only manufacturer’s recommended accessories. Use the vacuum only for its intended use.
3.
To protect against a risk of electric shock, do not immerse any part of the system in water or other liquids.
4.
Never yank cord to disconnect from outlet; instead, grasp plug and pull to disconnect.
5.
Do not pull cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Keep cord away from heated surfaces.
6.
Do not leave the vacuum plugged in when unattended. Unplug the electrical cord when not in use and before servicing.
7.
Turn off all controls as applicable before unplugging from electrical outlet.
8.
Do not handle plug or hand vacuum with wet hands or operate without shoes.
9.
Do not allow cord to touch hot surfaces.
10. Do not run appliance over cord.
11. Do not operate the system with a damaged cord or plug, or if the appliance or any other part of the system has been dropped or damaged. To avoid the risk of electric shock, do not disassemble or attempt to repair the vacuum. Return the unit to
FANTOM (see warranty) for examination and repair. Incorrect re-assembly or repair can cause a risk of electrical shock or injury to persons when the vacuum is used.
12. Close supervision is necessary for any appliance being used by or near children.
13. Do not leave the system unattended while connected.
14. Do not allow to be used as a toy. Close attention is necessary when used by or near children, pets or plants.
15. Keep hair, loose clothing, fingers and all parts of body away from opening and moving parts.
16. Do not use vacuum to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.
17. Do not pick up anything that is burning or smoking such as cigarettes, matches or hot ashes.
18. Use extra care when cleaning on stairs.
19. Do not use the vacuum without all the filters in place.
20. Use only extension cords UL-rated or cUL at 15 amperes. Extension cords rated for less amperage may overheat. Care should be taken to arrange the cord so that the cord cannot be pulled or tripped over.
21. Do not put any objects into openings. Do not use with any opening blocked. Keep free of dust, lint, hair and anything else that may reduce air flow.
22. Store your appliance indoors in a cool, dry area.
23. Keep your work area well lit.
24. Keep end of hose, wands and other openings away from your face and body.
25. Do not use outdoors or on wet surfaces.
Use only on dry surfaces.
26. Using improper voltage may result in damage to the motor and possible injury to the user. Correct voltage is listed on rating label.
27. If the supply cord of this appliance is damaged, it must only be replaced by
FANTOM, because special purpose tools are required.
28. Connect to a properly grounded outlet only. See grounding instructions.
SAVE THESE INSTRUCTIONS
For Household or Commercial Use Only
GROUNDING INSTRUCTIONS
This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 120-volt circuit, and has a grounding attachment plug that looks like the plug illustrated at right.
Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adaptor should be used with this appliance.
1 Rev. 11/04
PRECAUTIONARY MEASURES
IMPORTANT:
If the suction opening in the unit or the hose is BLOCKED, switch off the vacuum cleaner and remove the blocking substance before you start the unit again.
1. Do not operate the vacuum cleaner too close to heaters, radiators or cigarette butts.
4. When pulling out the power plug from the wall outlet, pull the plug not the power cord.
2. Before inserting the power plug into the wall outlet, make sure that your hands are dry.
5. Do not pick up anything that is burning or smoking such as cigarettes, matches or hot ashes.
6. Do not use without all filters in place.
3. Before you start vacuuming, make sure to remove large or sharp objects that might damage the debris screen.
ORDERING REPLACEMENT HEPA DUST CUP FILTERS
TO ORDER REPLACEMENT HEPA FILTERS
Item XF621H for Model FM625H
Call: 1 (800) 275-9251
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
FOR TECHNICAL SUPPORT for Model FM625H
Call: 1 (800) 275-9251
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
Please Note:
The HEPA Filter is washable. It should, however, be replaced every three (3) to six
(6) months depending on usage to ensure peak performance of your vacuum.
The exhaust filters and filter ring are rinseable. They should however be replaced every three (3) months to ensure peak performance of your vacuum.
Important:
Make sure that ALL filters have been completely air dried for 24 hours before reinstalling back in the vacuum.
2 11
PROBLEM
VACUUM WILL
NOT OPERATE
TROUBLE SHOOTING GUIDE
POSSIBLE REASON POSSIBLE SOLUTION
1. Power cord not firmly plugged into outlet.
2. No power in wall outlet. servicing.
4. Thermostat
1. Plug unit in firmly.
2. Check fuse or breaker. Replace fuse/reset breaker.
3. Call 1-800-275-9251.
4. Turn the unit off and unplug from outlet. Allow unit to cool down, then restart.
VACUUM WILL
NOT PICK-UP OR
SUCTION POWER
IS WEAK
1. Dust cup is full.
2. Unit
3. HEPA Filter needs cleaning or replacing.
4. Debris screen needs cleaning.
5. Exhaust filters or filter ring needs cleaning.
1. Empty and clean dust cup.
2. Turn unit off and unplug from wall outlet. Remove Dust Cup
Filter and check for object(s) in air duct and remove.
3. Clean or replace HEPA Filter.
4. Clean debris screen.
5. Clean exhaust filters and filter ring.
DUST ESCAPING
FROM VACUUM
1. Dust cup is full.
2. Dust Cup is not installed correctly.
1. Empty and clean dust cup.
2. Review Dust Cup instructions.
VACUUM, HOSE
OR BRUSHES
WILL NOT PICK-UP clogged.
2. Dust cup is full.
1. Remove hose and/or brushes.
Remove obstruction from hose and /or brush.
2. Empty and clean dust cup.
GETTING TO KNOW YOUR BAGLESS STICK VAC
10
1.
Hand Grip
2.
Hose Holder
3.
Flexible Hose
4.
Carrying Handle
5.
Intelli-Sense TM Filter Monitor
6.
Handle Release
7.
On/Off Switch
8.
Exhaust Filter Cover (x2)
9.
Dusting Brush
10. Dust Cup Release
Illustrations may differ from actual product
Technical Specifications
Voltage:
Power:
120V., 60Hz.
12 Amps
3
11. Dust Cup Cover
12. Dust Cup
13. Trap Door Release Button
14. Motorized Floor Brush
15. Hose Handle
16. Pet Hair Brush
17. Air Driven Turbo Brush
18. Nozzle Release Pedal
19. Power Cord Quick Release
20. Extension Tube
21. Crevice Tool
OPERATING INSTRUCTIONS
WARNING:
Always remove the power plug from the wall outlet before assembling or removing accessories.
Inserting The Handle Into The Main
Unit
• Insert the handle into the hole on the top of the unit. Make sure that the slot in the handle fits correctly into the opening. (Fig. 1)
• To remove the handle, press the handle release button and pull the handle up.
Attaching The Hose To The
Main Unit
• Hold the end of the removable hose handle and insert it into the hose connector. (Fig. 3).
Hose
Connector
Pin
Release Button
Fig. 3
Inlet
Hose
Fig. 1
Attaching The Motorized Floor
Brush To The Main Unit
• Insert the motorized floor brush into its location at the bottom of the main unit, in the direction of the arrow. (Fig. 2)
• Make sure that the motorized floor brush is firmly inserted into the floor brush socket.
• Insert the inlet hose into the floor brush hose connector that is on the floor brush. (Fig. 3)
Motorized Floor
Brush Release
Pin
Fig. 2
Motorized Floor
Brush Hose
Connector
Motorized
Floor Brush
Hose Connector
Winding & Unwinding The Power
Cord
This vacuum cleaner is equipped with a convenient cord storage feature. The power cord winds around the two cord holders at the back of the unit. The top one has a quick cord release feature.
Turn the cord hook to the left or the right to remove the power cord.
(Fig. 4)
When using the vacuum, attach the power cord to the cord holder so that the power cord is out of the way when you are vacuuming.
(Fig. 5)
Fig. 4
Cord holder
Fig. 5
4
OPERATING INSTRUCTIONS
Cleaning the Filter Ring
1. Around the HEPA filter there is a filter ring.
This is washable in lukewarm water.
(Fig. 16) To remove the filter ring, slide it off the HEPA filter.
2. We recommend washing the filter ring when you are washing your HEPA filter. Always allow the
Fig. 16 filter ring to air dry for 24 hours before replacing onto the HEPA filter. Never run the vacuum without all the filters in place.
Changing & Cleaning the Exhaust
Filter
The exhaust filter is a rinseable filter but should be replaced every three (3) months.
• To remove the exhaust filter covers, push the exhaust filter covers up.
Remove the filter. (Fig. 17)
• Rinse the exhaust filters in lukewarm water and air dry the filters completely for 24 hours. Do not use a washing machine to rinse the filters. Do not use a hair dryer to dry them. Air dry only.
Never operate the vacuum without the exhaust filters in place.
• When the filters are dry, replace into the exhaust filter covers and replace on the vacuum.
• Severely soiled or clogged filters should be thoroughly rinsed with fresh tepid water. A mild detergent can be used if required.
Exhaust
Filter
Cover
Fig. 17
Motor Thermostat
IMPORTANT:
This unit is equipped with a motor protective thermostat. If for some reason the vacuum cleaner should overheat, the thermostat will automatically turn the unit off. Should this occur:
• Push the On/Off button once.
• Disconnect the plug from the power source.
• Check the source of overheating problem. (i.e. clogged hose or filter)
• If clogged hose or filter is found, unclog the hose and replace the filters.
• Wait at least 45 minutes before attempting to reuse the vacuum.
• After unit has cooled down for
45 minutes, plug in the cleaner and push the On/Off button. The vacuum should start again.
• If the vacuum still does not start, contact customer service at
1 (800) 275-9251.
9
2. To separate the filter assembly, hold the bottom of the debris screen and pull the dust cup cover out. Then remove the HEPA filter with the filter ring from the debris screen (Fig. 13)
Filter Assembly
Dust Cup
Cover
HEPA
Filter
Debris Screen
Fig. 13
3. Once you have removed the
HEPA filter from the debris screen, remove the filter ring from around the HEPA filter.
4. Vigorously “TapClean” the HEPA filter on a hard surface until no more dust is observed falling out.
(Fig. 14)
The HEPA filter may also be washed by running it under the tap allowing the water to run on the dirty side.
(Fig. 15) We
Fig. 14 recommend washing it once a month or when suction appears reduced. Always allow 24 hours for
Fig. 15 air drying before replacing into the vacuum.
Warning: Never over fill the dust cup - remove dirt and clean the
HEPA dust cup filter, filter ring and debris screen each time the dust cup is emptied during prolonged usage or risk motor damage.
OPERATING INSTRUCTIONS
Filter
Ring
8
PLEASE NOTE: The white pleated filter material in the HEPA Filter will discolor over time -This is NORMAL and will NOT affect the performance of the filter. If the HEPA filter is properly
"TapCleaned” after each use
Fig. A and suction does not return to 100%, then we suggest that the HEPA filter be “TapCleaned” vigorously until no more dust
Wash once a month or when suction appears reduced
Warning: Allow 24 hours for drying before replacing in unit.
can be removed, then rinsed under the faucet and allowed to air dry for 24 hours before refitting into the vacuum. (Fig. A)
This should be done once a month or when suction appears to be
reduced.
Note: Even though the HEPA filter is washable, it should be replaced every
3 to 6 months, depending on usage.
Warning:
Always empty the dust cup container and clean the HEPA filter, filter ring and debris screen before each use and during prolonged usage.
Never over fill the dust cup container remove dirt and clean the HEPA filter, filter ring and debris screen when dirt in dust cup is at or below the "MAX" level or during prolonged usage because you could risk damaging the motor.
If you wash the Hepa filter, make sure that it has completely air dried for 24 hours before inserting back into the vacuum.
Please Note: The HEPA Filter is washable. It should, however, be replaced every three (3) to six (6) months to ensure peak performance of your vacuum.
The filter ring and exhaust filter are also rinseable but they should be air dried for
24 hours before replacing into the vacuum. They should however be replaced every three (3) months to ensure peak performance of your vacuum.
Important: Make sure that ALL filters are completely dry before re-installing back in the vacuum.
OPERATING INSTRUCTIONS
On/Off Switch
The On/Off switch has three different positions. (Fig.6)
• Push on the "I" side to turn the vacuum ON. Set the vacuum here when using the removable hose handle with the accessories or when vacuuming bare floors.
• Push on the “II" side to turn the motorized floor brush on.
• Push on the “O” side to turn the vacuum to the OFF position.
Using The Unit With The
Accessories
• Remove the removable hose handle from the hose connector.
• Attach the extension tube, crevice tool, the dusting brush, pet hair brush or air driven turbo brush to the end of the hose. (Fig. 8)
Fig. 8
= OFF
= ON
(Bare Floors/Tools)
= ON
(Carpet)
Fig. 6
Using The Unit With The Motorized
Floor Brush
• Unwind the power cord and plug into the 120V outlet.
• Press the On/Off switch to the “II” position so that both the vacuum and the motorized floor brush is turned “ON”
NOTE:
When vacuuming deep pile carpets or hard wood floors, lower the angle of the handle for easier maneuverability. (Fig. 7)
Fig. 7
Manual Variable Suction Control
Your vacuum cleaner includes a variable suction control valve on the hose handle. The suction power can be adjusted by moving the slide to the desired position. For example. Less suction is required on upholstery and draperies compared to thick shag carpets, which require maximum suction.
Extension Tube
For hard to reach places. Use with crevice tool or with dusting brush.
Crevice Tool
For radiators, crevices, corners, baseboards and between cushions.
5
Dusting Brush
The dusting brush is used for the furniture, venetian blinds, books, lamp shades and shelves.
Pet Hair Removal Brush
The pet hair removal brush is for use on upholstery, drapes and other fabric surfaces to remove lint, pet hair, etc. THE PET HAIR REMOVAL
BRUSH IS NOT INTENDED TO BE
USED AS A PET GROOMING
DEVICE.
OPERATING INSTRUCTIONS
Using The Unit With Air Driven
Turbo Brush
The efficiency of your air driven turbo brush depends on the bristle brush rotating at high speed. Strong air suction is needed to accomplish this. In order to ensure that maximum air suction is maintained, please read the following instructions:
1. Empty the dust cup frequently.
2. Always vigorously “TapClean” the
HEPA filter, filter ring and the debris screen when emptying the dust cup container.
3. Ensure that the rotating brush is kept free of hair and string which may accumulate and decrease brush performance.
4. Keep air driven turbo brush turbine free of dirt and foreign matter. (See illustration for cleaning instructions.)
Attaching the Air Driven Turbo
Brush to the Flexible Hose
To use the air driven turbo brush to clean upholstery:
1. Remove the flexible hose from the hose connector. (Fig. 9)
2. Push the air driven turbo brush onto the end of the flexible hose as far as it will go.
Important: In order to ensure that maximum air suction is maintained, empty the dust cup frequently and tap clean the HEPA filter, filter ring and debris screen at the same time. Ensure that the rotating brush is kept free of hair and string which may accumulate and decrease brush performance.
Cleaning Air Driven Turbo Brush
Locking Latch
Tilt
Upwards
Turbine
From time to time, the turbine of your turbo brush will require cleaning. To do this:
1. Remove the turbo brush from the hose or telescopic extension tube.
2. Slide locking latch forward then tilt the top housing of the brush upwards. The top housing is hinged and will tilt up approximately 45° only.
3. There may be some dust, lint, hair, etc on the turbine wheel. Remove as much of this as possible.
4. You may also use the unit’s hose with crevice tool attached and use the vacuum to remove any additional debris from the turbine.
5. Ensure that the turbine wheel moves freely by rotating it with your finger. If the turbine does not rotate, call
Customer Service for help.
6. Once clean, close the top cover of the turbo brush and slide the locking latch toward the rear of the brush to lock.
Fig. 9
6
Fig. 10
OPERATING INSTRUCTIONS
Intelli-Sense
TM
Filter Monitor
When the Intelli-Sense TM Filter
Monitor lights up, it means that the dust cup is full or the HEPA filter, filter ring and debris screen need cleaning.
You must empty the dust from the dust cup and clean the HEPA filter, filter ring and debris screen right away.
Emptying the Dust Cup Container
Warning:
Always unplug the unit from electrical outlet before opening the Dust Cup (container).
Important:
Do NOT use the vacuum without the HEPA filter and filter ring in place.
1. To remove the dust cup container, press down on the dust cup release and pull the dust cup container out from the vacuum. (Fig. 10)
2. To empty the dust cup container, hold the dust cup from the top over a garbage container and press on the trap door release button that is on the front side of the dust cup container to release the dust cup bottom (Fig. 11)
Hold
Push
Fig. 11
Cleaning the HEPA Filter
Warning
: After each Use -
Always remove the Filter
Assembly, then vigorously “TapClean”
HEPA Filter and clean Debris Screen and Filter Ring until no more dust can be removed.
IMPORTANT, Please Note : The
“TapClean” HEPA Filter will stop most of the tiniest dust particles and airborne allergens from re-entering the air you breathe. In fact it stops 99.97% of all particles as small as 0.3 microns - many times smaller than a human hair!!!
Because of this incredible filtration performance, the HEPA Filter will quickly accumulate, inside the white filter folds, many fine dust particles that are difficult to see but which will eventually block or reduce your suction power - if not cleaned properly.
1. To remove the filter assembly from the dust cup, hold the dust cup container in one hand and with the other hand, turn counter clockwise and pull out the filter assembly.
(Fig. 12)
Fig. 12
Filter Assembly
Dust Cup
Container
7
Advertisement
Key features
- Lightweight and easy to maneuver
- HEPA filtration for improved air quality
- Multiple attachments for versatile cleaning
- Variable suction control for different surfaces
- Convenient cord storage