Cisco LE III Type 4 with 40 52 MHz Split (Linear Tilt) Audio Amplifier Data Sheet

Cisco LE III Type 4 with 40 52 MHz Split (Linear Tilt) Audio Amplifier Data Sheet | Manualzz
RF Electronics
Line Extender III
Type 3
750 MHz with 40/52 MHz Split
22711
NOTE: The output tilt referenced in this document is defined as a LINEAR output tilt (as opposed to a CABLE output tilt). The distortion
and noise figure specifications are applicable across the full operational temperature range (as opposed to being referenced to 68°F).
When calculating end of line performance, the specifications used for all of the amplifiers in a given cascade must be of similar format,
due to the fact that all amplifiers in a cascade must operate with a similar output tilt (either all LINEAR output tilt or all CABLE output tilt).
DESCRIPTION
The Type 3 RF amplifier module
offers a high performance design
solution for the latest HFC networks.
The amplifier module comes preconfigured with interstage equalizer,
diplexers, reverse amplifier, and
either AGC for a 3A, Thermal for a
3T, or jumper for a 3M module, in
order to achieve optimum station
performance. Additionally,
maximum flexibility in reverse signal
path alignment is achieved via the
reverse test point and plug-in pad for
the reverse input.
The Type 3 amplifier module provides one (bridger level) output.
FEATURES
• 60 and 90 V AC powering capability
• 15 ampere current capacity (steady state) and 25 ampere surge survivability
• Integrated reverse amplifier, with optimized diplex filter group delay for
forward and reverse paths
• Reverse input test point and input pad allowing optimum reverse path
alignment
• Improved station frequency response
• Unitized design (amplifier and power supply in a single module) enabling
simplified and faster maintenance
• High efficiency, transformerless power supply lowering system operating cost
• RF testpoints using directional couplers for optimum accuracy
• Surge Resistant™ Circuitry ensuring hybrid protection without fuses or other
nuisance failure causing devices
Scientific-Atlanta 1-800-433-6222
22882
LINE EXTENDER III-TYPE 3 – 5-40/52-750 MHz
Forward
Input
-20 dB T.P.
FWD
Forward
Output
-20 dB T.P.
Pad
EQ
TRIM
AC
Bypass
ISEQ
Pad
Jumper,
Thermal,
or AGC
AGC
Coupler
FWD
AC
Bypass
REV
REV
Reverse
Output
-20 dB T.P.
Reverse
Input
-20 dB T.P.
AC
AC
EQ
T4236
Pad
Pad
Reverse
Injection
-20 dB
LINE EXTENDER III – TYPE 3 – 5-40/52-750 MHz
General Station Performance Data
Pass Band
Amplifier Type
Operational Temperature Range
Frequency Response
Auto Slope & Gain Range
Return Loss
Operational AC Through Current
Max AC Through Current (2 hrs)
Hum Modulation @ 10 A
(over specified frequency range)
Hum Modulation @ 15 A
(over specified frequency range)
Units
MHz
--degrees
dB
dB
dB
Amps
Amps
dB
dB
Test Points (±0.5 dB)
Reference Output Level–High Freq.
dB
dBmV
Reference Output Level–Low Freq.
Reference Output Tilt 1
dBmV
dB
Interstage Level Control (type)
Interstage Equalizer (value - type)
Current Draw @ 24 V DC (Typ.)
Operational Gain (minimum) 3, 9
Internal Tilt 2 (±0.5 dB)
Noise Figure 3 @ 54 MHz
Noise Figure 3 @ 750 MHz
Reverse Noise Figure 7, 9
dB
Amps
dB
dB
dB
dB
dB
Forward
52-750
PHD
-40 to +140 F
±0.5
±4
16
15
25
70 (55-750 MHz)
62 (55-150 MHz)
60 (151-600 MHz)
58 (601-750 MHz)
-20
47.5 @ 750 MHz
44 @ 550 MHz
35 @ 54 MHz
+12.5
3M
3T
3A
None
Thermal
AGC w/
Man. Backoff
9 - fixed
14.5 - fixed
9 - fixed
0.63
0.63
0.73
30.5
29.5
28.5
+7.2
+7.2
+7.2
7.5
7.5
7.5
9
9
9
-------
Reverse
5-40
PP
-40 to +140 F
±0.5
N/A
16
N/A
N/A
58 (5-15 MHz)
65 (16-40 MHz)
50 (5-15 MHz)
59 (16-40 MHz)
-20
35 @ 40 MHz 8
35 @ 5 MHz 8
0
N/A
N/A
0.13
19.5
0
----6.0
Forward and Reverse Performance with Specified Channel Loading
CW Channel Loading
Composite Triple Beat 5,7
Cross Modulation 6,7
Composite Second Order 5,7 (high side)
Units
NTSC
dB
dB
dB
3M
3T
3A
79 w/digital 4 79 w/digital 4 79 w/digital 4
71.0
71.0
70.0
67.0
67.0
65.0
68.0
68.0
67.0
Reverse
6
92.0
80.0
82.0
Delay Characteristics
Forward
(Chrominance to Luminance Delay)
Freq. (MHz)
Delay (ns)
55.25 - 58.83
28
61.25 - 64.83
12
67.25 - 70.83
7
77.25 - 80.83
3
Reverse
(Group Delay in 1.5 MHz BW)
Freq. (MHz)
Delay (ns)
38.5 - 40.0
30
33.5 - 35.0
8
10.0 - 11.5
6
5.0 - 6.5
60
Notes:
(1) Reference output tilt is specified as “LINEAR” tilt (as opposed to traditional “cable” tilt).
(2) Down tilt, the effect of cable, is represented by a (-). Up tilt, the effect of equalization, is represented by a (+).
(3) Forward gain and noise figure measured with 0 dB input EQ and 1 dB input pad.
(4) “Digital” refers to 550-750 MHz loading with 33 QAM carriers at -6 dB levels relative to analog video carrier levels.
(5) CTB and CSO measured using CW carriers, with spectrum analyzer as the measurement device.
(6) X-Mod (@ 15.75 kHz) specified using 100% synchronous modulation and frequency selective measurement device.
(7) Distortions and Noise Figures are typical and specified over the operational temperature range.
(8) Reverse output reference level with a 0 dB reverse output equalizer and factory selected reverse output pad.
(9) Reverse gain and noise figure is for station with 0 dB reverse input pad, 0 dB reverse output EQ, and factory selected reverse output pad.
Unless otherwise noted, the above specifications reflect typical station performance at stated reference levels in the recommended operating configuration,
including the input equalizer and reverse filters where applicable. Unless otherwise noted, specifications are based on measurements made in accordance
with NCTA Practices for Measurements on Cable Television Systems using standard frequency assignments and are referenced to 68°F (20°C).
Line Extender III-Type 3 — 5-40/52-750 MHz
Station Powering Data
I DC
(Amps)
AC Voltage
90
85
80
75
70
65
60
55
AC Current (A)
0.76 0.38 0.41 0.42 0.44 0.46 0.48 0.49 0.52
Power (W)
22.2 21.8 21.8 21.9 21.5 21.8 21.8 21.7
Type 3A
AC Current (A)
0.86 0.42 0.46 0.46 0.48 0.50 0.52 0.54 0.57
Power (W)
24.7 24.4 24.3 24.4 24.2 24.3 24.4 24.3
Data is based on stations configured for 2-way operation. Power supply has 30 V AC undervoltage lockout.
Line Extender III
Type 3M/3T
ORDERING INFORMATION
Amplifier Module - 1 required
• # 545397 - Type 3M amplifier module
Note: 3M amplifier module comes configured with reverse
amplifier, 9.0 dB interstage EQ, interstage pad, reverse output
pad, 0 dB reverse output EQ, 40/51 diplex filters, integrated
power supply.
• # 545297 - Type 3T amplifier module with Thermal
Note: 3T amplifier module also comes configured with reverse
amplifier, 14.5 dB interstage EQ, interstage pad, reverse output
pad, 0 dB reverse output EQ, 40/51 diplex filters, integrated
power supply.
• # 545197 - Type 3A amplifier module with AGC. AGC has
445.25 MHz pilot frequency and manual temperature backoff
control.
Note: 3A amplifier module also comes configured with reverse
amplifier, 9.0 dB interstage EQ, interstage pad, reverse output
pad, 0 dB reverse output EQ, 40/51 diplex filters, integrated
power supply.
50
0.55
22.3
0.60
24.8
35
0.67
22.2
0.76
24.6
Optional Accessories
• #467351 230 V AC Crowbar Surge Protector
• Plug-in Cable Simulator. Simulates cable losses, creating tilt
opposite that of Equalizers. Use in place of Forward Input
Equalizer as needed to maintain proper output tilt in short
spaced locations. Available in 1.5 dB steps from 1.5 dB to
12.0 dB cable loss at 750 MHz. Order Model CS 750-*
(* denotes CS value); specify value.
Related Equipment
• #501111 Long Reach Test Point Adapter
• #276982 Reverse Injection Probe (3 dB insertion loss)
• #548771 Pad Insertion/Removal Tool
MECHANICAL SPECIFICATIONS
• # 545443 Uncoated 2-port housing
• # 545444 Coated 2-port housing
Housing Dimensions
11.5 in. L x 9.5 in. H x 4.0 in. D
292.1 mm L x 241.3 mm H x 101.6 mm D
Weight
Housing 6 lbs, 6 oz; 2.9 kg
Module 2 lbs, 13 oz; 1.3 kg
• Plug-in Pads (attenuators):
– 1 required for forward (1 input)
– 2 required for reverse (1 input, 1 output)
– 1 required for AGC only if amplifier output level at pilot
frequency is NOT 42 dBmV (AGC comes configured with a
14 dB pad, which is appropriate for 42 dBmV output level
at pilot frequency).
Available in 0.5 dB steps from 0 to 20 dB. Order Model PP-*
(* denotes pad value); specify value.
40
0.61
21.8
0.68
24.4
• Plug-in Forward Input Equalizer, 1 required. Available in 1.5 dB
steps from 0 to 28.5 dB at 750 MHz. Order Model EQ750-*
(* denotes equalizer value); specify value.
• Plug-in Reverse Output Equalizer, 1 required. Available in
1.0 dB steps from 1.0 to 12.0 dB at 40 MHz. Order Model
EQ40S -* (* denotes equalizer value); specify value.
Housing - 1 required (all have 15 amp capacity)
Required Accessories
45
0.58
22.3
0.64
24.8
Specifications and product availability are subject to change without
notice.
Scientific Atlanta and the Scientific-Atlanta logo are registered trademarks
of Scientific-Atlanta, Inc.
Surge Resistant is a trademark of Scientific-Atlanta, Inc.
Scientific-Atlanta, Inc.
http://www.sciatl.com
United States: 4261 Communications Drive, P.O. Box 6850, Norcross, GA 30091-6850; Tel: 800-433-6222; Fax: 770-903-4617
Canada: 7725 Lougheed Highway, Burnaby, BC V5A 4V8; Tel: 604-420-5322; Fax: 604-420-5941
United Kingdom: Home Park Estate, Kings Langley, Herts WD4 8LZ, England; Tel: 44-923-266-133; Fax: 44-192-327-0448
Australia: Unit 2, 2 Aquatic Drive, P.O. Box 292, Frenchs Forest, NSW 2086, Australia; Tel: 61-2-9452-3388; Fax: 61-2-9451-4432
Singapore: 1 Claymore Drive, #08-11 Orchard Towers, Singapore 229594; Tel: 65-733-4314; Fax: 65-733-2706
Hong Kong: Suite 56 & 57, 5/F New Henry House, 10 Ice House Street, Central, Hong Kong; Tel: 852-2522-5059; Fax: 852-2522-5624
P/N 570848 Rev B
© 1998 Scientific-Atlanta, Inc.
All rights reserved.
Printed in USA.
0498M
Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Download PDF

advertisement