DESCRIPTION
PT712-EI is a digital thermostat with a room and floor sensor, specially designed for electric
floor heating control. The internal-external sensor combination enables the regulation of:
1) floor temperature (external sensor) - suitable, for instance, for bathrooms where a warm floor is
desirable, irrespective of the room temperature;
2) room temperature (internal sensor) - when comfortable room temperature is required;
3) combined (both sensors)
- the internal sensor scans the room temperature, while the
external one monitors the maximum floor temperature;
comfortable room temperature is required, however, with
simultaneous monitoring of the floor temperat
(suitable for wooden and laminated floors).
Another advantage is simple installation in the KU/KP68 junction boxes by means of the PLUG-IN
system, as well as the possibility of setting 2 weekly programs with 6 temperature changes per day.
INSTALLATION AND LOCATION
Install the thermostat in a suitable place (minimum height of 1.2-1.5 m above the floor) where its operation
will not be affected by direct hot/cold air flow, sunshine or other disturbing influences. Do not mount the
thermostat on an exterior wall either. In rooms with increased humidity (bathroom, kitchen), observe valid
standards and install the thermostat as far from the bathtub, shower, basin or sink as possible.
The external floor sensor must be located in a flexible plastic tube embedded in the floor, as near to the
surface as possible. The tube must be sealed and protected against in-leak of building materials so that
the floor sensor can be replaced easily, if need be. It must not run parallel with power conductors! It can
be extended to a maximum length of 30 metres. The installation can only be done by a properly qualified
person! Disconnect power supply before installation!
1) Switch off the main circuit breaker.
2) Check that the junction box is placed parallel with the wall.
3) Separate the power part of the thermostat from its microprocessor (main) part; see Fig. 1.
4) Pull the connecting terminals out of the thermostat rear part, see Fig. 2.
5) Connect conductors to the terminals acc. to the wiring diagram below, see Fig. 3.
6) Insert the terminals into the thermostat terminals and fasten the power part to the junction
box, see Fig. 4 and 5.
7) Insert the main part connector into the power part and push it; the metal springs must
fit in the given holes, see Fig. 6 and 7.
8) Switch on the main circuit breaker; the thermostat is ready for operation.
Note: We recommend you test correct connection after installation, see the TEST function (page 7).
Wiring diagram:
N L
NTC 10k
PULL
NTC 10k
L'
L‘ = disconnected phase
2
Fig. 1
power part
main part
COM NO
2760 W
COM NO
2760 W
N L
When using the low tariff
connecting
terminals
PULL
Fig. 2
Fig. 3
Fig. 4
PUSH the connecting
terminals in.
9
NO COM
L N
PULL out the connecting terminals.
Connect according to the wiring diagram.
Fig. 6
Fig. 5
Screw the power part to
the junction box.
Fig. 7
PUSH the
main part
onto the
power part.
Connector and holes
for metal springs.
DESCRIPTION OF LCD AND CONTROL BUTTONS
MENU
1, Current date (in the Prog mode, selection of number of days for
programming)
2, Operating modes: OFF/PROG/AUTO/MANU/case=HOLIDAY
3, Current room temperature
4, Indication of room temp. measurement by the exter. sensor.
5, Heating on indication
6, Button lock indication
7, CLOC mode indication (current date and time setting)
8, Required temperature and current time display / listing of operating
modes (this line is explained in detail with every mode)
9, Battery supply indication (in case of 230V/50Hz voltage failure,
it is functional only after 1 day of operation, when the backup
battery is charged!)
10, Indication of setting the external sensor as the floor one
11, Anti-freeze temperature of 3 °C
12, Comfortable temperature in the MANU mode
13, Economical temperature in the MANU mode
3
MENU button:
short press = opens the main menu and
confirmation (ENTER)
long press (approx. 3 sec.) = back from the
main menu
/
button:
basic mode = opens info
main menu =browse and set current values
simultaneous press of the MENU and
buttons (in basic mode) = key lock
simultaneous press of the MENU and
buttons (in basic mode) = key unlock
simultaneous press of the MENU and
/
buttons (in main menu) = return to basic mode
Note: The LCD backlight is activated by pressing any button!
OPERATING MODES
By pressing any button, you activate the display backlight. Next, pressing the MENU button
briefly, you enter the main menu, in which you can choose the operating modes.
AUTO
The thermostat works according to the preset weekly program.
Press the MENU button and choose the AUTO mode with
the
/
buttons. Press MENU to confirm.
AUTO OFF
The thermostat is switched off until the next change given by the
program.
Press the MENU button and choose the AUTO OFF mode with the
/
buttons. Press MENU to confirm.
(default setting of 21°C)
MANU
The thermostat works according to the preset temperature
which remains constant until the next manual change.
Press the MENU button and choose the MANU
/
buttons. Press MENU to confirm.
MANU
,
mode with the
(default setting of 19°C)
The thermostat works according to the preset temperature
which remains constant until the next manual change.
Press the MENU button and choose the MANU
/
buttons. Press MENU to confirm.
,
mode with the
MANU OFF
The thermostat is switched off until the next manual change.
Press the MENU button and choose the MAN OFF mode with the
/
buttons. Press MENU to confirm.
HOLIDAY IN THE AUTO MODE
The thermostat maintains the preset temperature until the given
date and time. When the preset period expires, it returns to the
AUTO mode automatically.
Press the MENU button and choose the AUTO mode with the
/
buttons. Press MENU to confirm.
The temperature value flashes on the LCD. Set the desired temperature with the
/
buttons and press MENU to confirm it;
next, set the hour, minute, day, month and year when your holiday
ends; confirm each setting by pressing MENU .
After setting, the device automatically switches to the HOLIDAY
mode within 1 minute! The holiday end date appears on the display!
4
HOLIDAY IN THE MANU
MODE
The thermostat maintains the preset temperature until the given
date and time. When the preset period expires, it returns to the
MANU
mode automatically.
Press the MENU button and choose the MANU mode with the
/
buttons. Press MENU to confirm.
The temperature value flashes on the LCD. Set the desired temperature with the
/
buttons and press MENU to confirm it;
next, set the hour, minute, day, month and year when your holiday
ends; confirm each setting by pressing MENU .
After setting, the device automatically switches to the HOLIDAY mode
within 1 minute! The holiday end date appears on the display!
HOLIDAY IN THE MANU
MODE
The thermostat maintains the preset temperature until the given
date and time. When the preset period expires, it returns to the
MANU mode automatically.
Press the MENU button and choose the MANU mode with the
/
buttons. Press MENU to confirm.
Further setting is the same as for the MANU
mode.
CLOC
Setting the current date and time.
Press the MENU button and choose the CLOC mode with
the
/
buttons. Press MENU to confirm.
The current hour value flashes on the LCD. Set the current hour and
confirm it by pressing MENU then, set the minutes and seconds; next,
the current date appears; again, set the current day, month and year
with the
/
buttons. Confirm each setting by pressing MENU .
PROG
Setting of weekly programs (2 weekly programs are available,
each with 6 changes per day).
Press the MENU button and choose the PROG mode with
the
/
buttons. Press MENU to confirm.
P1 (the first weekly program) flashes on the LCD; press MENU to confirm it;
The programmed day number flashes on the LCD, choose one
of the options with the
/
buttons (you can program “day
after day”, or Mon-Fri, Sat-Sun or Mon-Sun). Press MENU to confirm your choice. The display shows U1 for setting the first temperature change; set the temperature with the
/
buttons
and confirm with the MENU button. Set the switching time with
the
/
buttons and confirm with the MENU button again.
The display shows U2 for setting the second temperature
change. Follow the procedure for the first temperature change.
In this way, you can set up to 6 temperature changes per day. To
/
buttons
return to the basic mode, press the MENU and
simultaneously.
5
CONST
Setting of the regulation parameters.
Press the MENU button and choose the CONST mode with the
/
buttons. Press MENU to confirm it. The first parameter appears on the LCD.
1 MINIMUM REGULATED TEMPERATURE
Limitation of the minimum temperature adjustable.
It can be set within the range 3°C to 10°C.
Set the pertinent value with the
/
buttons and press
to confirm.
MENU
2 MAXIMUM REGULATED TEMPERATURE
Limitation of the maximum temperature adjustable.
It can be set within the range 15°C to 99,5°C.
Set the pertinent value with the
/
buttons and press
to confirm.
MENU
3 HYSTERESIS
The hysteresis can be set from 0.1 to 5 °C. If, for example, the
hysteresis is 1 °C and the required temperature is 20 °C, the thermostat switches off at 20 °C and switches on again at 19 °C.
Set the pertinent value with the
/
buttons and press MENU
to confirm.
4 MINIMUM SWITCH-ON TIME IN HYSTERESIS
Here, you can set the minimum switch-on time of the heating device in
hysteresis in minutes. It can be set within the range 1 to 5 minutes.
Set the pertinent value with the
/
buttons and press MENU
to confirm.
5 EXTERNAL SENSOR SELECTION
Make your choice with the
/
buttons according to the application type and press MENU to confirm.
---
The external sensor, if connected, measures the temperature
at the point of location (suitable, for instance, for bathrooms,
where you wish to have a warm floor irrespective of the
room temperature);
This use of the sensor is indicated by the
sign on the LCD.
15…99,5°C The external sensor, if connected, monitors the floor
temperature; the maximum permissible temperature is set
for the floor heating (you regulate with the room
temperature, monitoring the floor temperature
at the same time).
The floor (monitoring) sensor is indicated by the
sign on the LCD.
If the preset limit temperature is exceeded, the thermostat is switched off irrespective of
the room temperature, and the STOP message appears on the LCD. Once the external
sensor temperature drops by 0.5 °C, the heating device is switched on again.
If the sensor is not connected or it is defective, the C2.Err error message appears on the
LCD.
6
After connecting the external sensor, it is NECESSARY
to RESET the device (see parameter 6)!
6 FIRMWARE VERSION / DEFAULT SETTING RECOVERY
Information on the firmware version. If you keep pressing the
button (approx. 3 sec), the RESET message appears briefly
on the LCD, and the thermostat recovers the default setting!
You can exit the CONST mode at any time by simultaneously pressing the
buttons (return to the basic mode).
MENU
and
/
OTHER FUNCTIONS
INFO
By pressing the
/
buttons in the basic mode, you can view the following information:
REQUIRED TEMPERATURE
In the basic mode, press the
/
buttons. The LCD shows
the required temperature value for the current operating mode
(it can be changed with the
/
buttons; in the AUTO
mode, the change is short-term – until the next change in the
program; in the MANU mode, the change is permanent).
With another press of the MENU button, you can switch to:
SELECTED PROGRAM NUMBER - in the AUTO mode only
This is used for quick change of the program selected in the
AUTO mode. If both P1 and P2 programs are preset, they can be
changed, after a week for example, with the
/
buttons.
With another press of the
MENU
button, you can switch to:
OPERATING HOURS
The LCD shows the operating hour value of the heating
device. You can clear it by pressing the
button.
MENU
button, you can switch to:
With another press of the
TEST
The LCD shows the TEST message, which can be switched to
the LCD test on/off with the
/
buttons (the output relay
will be switched on/off several times).
We recommend using this function for the first use of the
thermostat to check its correct connection!
With another press of the MENU button, you can view prior information
if the external sensor is connected as the floor (monitoring) one:
CURRENT TEMPERATURE OF THE FLOOR SENSOR
The LCD shows the current temperature value of the floor sensor.
To return to the basic mode, keep pressing the MENU button (for approx. 3 sec)!
LOCK
In the basic mode, simultaneously press the MENU and
buttons, the buttons will lock (the
key sign on the LCD). Unlocking can be done by simultaneously pressing the MENU and
buttons.
7
DIGITAL THERMOSTAT
PT712-EI
Used for the control of electric floor heating (heating cables, mats, foils).
It enables regulation according to the room temperature with possible floor temperature monitoring. Using the thermostat, you can reduce heating
costs and, at the same time, achieve thermal comfort at the given time.
Properties:
4 maximum floor temperature limit value
setting
4 2 weekly programs with 6 temperature
4 quick change of the required temperature
changes per day
4 backlit display
4 operating hours information
4 HYSTERESIS setting option
4 child lock – locking of keys
4 heating source minimum switch-on time
4 backup in case of voltage failure for
setting
more than 100 hours
4 operating modes:
4 simple installation (PLUG-IN system)
AUTO/MANU/OFF/HOLIDAY
4 elegant design of the VENUS switch series
The PLUG-IN system = quick and easy installation. The thermo- External sensor:
stat is divided into the power part and the main microprocessor
part, which can be connected by simple insertion of the interconnecting terminals. The input conductors (or external sensor) are
connected to the power part terminals and fastened to the junction box; then you can simply finish the installation by inserting the
main part onto the power part.
included in the package
type CT04-10k,
CYXY 2 x 0.5 mm,
10 kΩ, length 3 m,
PVC plastic case
Another advantage:
Dimensions:
81
The thermostat can be located in the multiple frame of the
VENUS design.
81
47
Technical parameters
WARRANTY CERTIFICATE
(a 2-year warranty is granted for the product)
Product number:
Date of sale:
Shop stamp:
Checked by:
Pb
LEAD FREE
v souladu s RoHS
Power supply
Number of adjustable temp.
Hysteresis
Minimum program time
Adjustable temp. range
Temperature setting
Minimum indication step
Measurement accuracy
Backup battery
Degree of protection
Output
Working temperature
230 V/ 50 Hz
6 different temp. per every day
0.1 to 5°C
10 minutes
+3°C to 99.5°C
by 0.5°C
0.1°C
± 0,5°C
more than 100 hours
IP20
max.12A (potential-free contacts)
0°C to +40°C
ELEKTROBOCK CZ s.r.o.
In case of warranty or
post-warrant service,
send the product to
the manufacturer’s
address.
Blanenská 1763
Kuřim 664 34
Tel./fax: +420 541 230 216
MADE IN CZECH REPUBLIC
www.elbock.cz
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement