Lenovo Flex System CN4093 10Gb Converged Scalable Switch


Add to my manuals
72 Pages

advertisement

Lenovo Flex System CN4093 10Gb Converged Scalable Switch | Manualzz

Lenovo Flex System CN4093 10Gb Converged Scalable Switch

Installation Guide

Important Product Information—

Before using this information and the product it supports, read

Appendix B, “Notices ” on page 61 of this

manual. Also read the product Warranty Information document, the Important Notices document, the Safety

Information document, the License Agreement for Machine Code (LAMC) document, and the Environmental

Notices and User Guide document located at Lenovo System x, ThinkServer and Storage product documentation .

September 2016 Edition

© Copyright Lenovo 2016

Portions © Copyright IBM Corporation 2014.

LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant a General

Services Administration “GSA” contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract No. GS-35F-05925.

Lenovo and the Lenovo logo are trademarks of Lenovo in the United States, other countries, or both.

Contents

Safety Information . . . . . . . . . . . . . . . . . . . . . . . . 5

Safety Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

UL Regulatory Information . . . . . . . . . . . . . . . . . . . . . . 8

© Copyright Lenovo 2016

Chapter 1. The CN4093 10Gb Converged Scalable Switch . . . . . . . . 9

Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

About this Installation Guide . . . . . . . . . . . . . . . . . . . . .12

Notices and Statements in this Document . . . . . . . . . . . . . . .12

Related Documentation . . . . . . . . . . . . . . . . . . . . . . .13

Chapter 2. Installing and Removing the CN4093 . . . . . . . . . . . 15

Before Installing the CN4093 . . . . . . . . . . . . . . . . . . . . . . .17

Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . .18

System Reliability Guidelines . . . . . . . . . . . . . . . . . . . . .19

Handling Static-Sensitive Devices . . . . . . . . . . . . . . . . . . .19

Installing the CN4093 . . . . . . . . . . . . . . . . . . . . . . . . . .20

Removing or Replacing the Switch . . . . . . . . . . . . . . . . . . . .22

Connecting Switch Ports . . . . . . . . . . . . . . . . . . . . . . . . .23

The Serial Console Port . . . . . . . . . . . . . . . . . . . . . . .23

The RJ-45 Management Port . . . . . . . . . . . . . . . . . . . . .24

Handling Transceiver Modules . . . . . . . . . . . . . . . . . . . .25

SFP+ Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

QSFP+ Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

Locating the Information Panels, LEDs, and External Ports . . . . . . . . . .32

Information Panel . . . . . . . . . . . . . . . . . . . . . . . . . .32

Information LEDs . . . . . . . . . . . . . . . . . . . . . . . . . .34

Chapter 3. Configuring the CN4093 . . . . . . . . . . . . . . . . 37

Establishing an Interface Through the CMM . . . . . . . . . . . . . . . .39

Enabling Management Through Data Ports . . . . . . . . . . . . . . . .40

Accessing the Switch Through the SSHv2/Telnet Interface . . . . . . . . . .41

Accessing the Switch Through the Serial-Port Interface . . . . . . . . . . .42

Accessing the Switch Through the Browser-Based Interface . . . . . . . . .43

Initial Configuration . . . . . . . . . . . . . . . . . . . . . . . . . .44

Chapter 4. Updating the Firmware and Licensing . . . . . . . . . . . 45

Determining the Level of Switch Firmware . . . . . . . . . . . . . . . . .46

Obtaining the Latest Level of Switch Firmware . . . . . . . . . . . . . . .47

Upgrading the Switch Firmware . . . . . . . . . . . . . . . . . . . . .48

Switch Firmware Upgrade Example . . . . . . . . . . . . . . . . . .49

Resetting and Restarting the Switch . . . . . . . . . . . . . . . . . . . .50

Acquiring Feature Licenses . . . . . . . . . . . . . . . . . . . . . . .51

Installing Feature Licenses . . . . . . . . . . . . . . . . . . . . . . . .53

Chapter 5. Solving Problems . . . . . . . . . . . . . . . . . . . 55

Running POST . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56

POST Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57

Parts listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58

Contents

3

Appendix A. Getting Help and Technical Assistance . . . . . . . . . 59

Appendix B. Notices . . . . . . . . . . . . . . . . . . . . . . 61

Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Important Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

Recycling information. . . . . . . . . . . . . . . . . . . . . . . . . . 65

Particulate Contamination . . . . . . . . . . . . . . . . . . . . . . . . 66

Telecommunication Regulatory Statement . . . . . . . . . . . . . . . . . 67

Electronic Emission Notices . . . . . . . . . . . . . . . . . . . . . . . 68

Federal Communications Commission (FCC) Statement . . . . . . . . . 68

Industry Canada Class A Emission Compliance Statement . . . . . . . . 68

Avis de Conformité à la Réglementation d'Industrie Canada . . . . . . . 68

Australia and New Zealand Class A Statement . . . . . . . . . . . . . 68

European Union - Compliance to the Electromagnetic Compatibility Directive

69

Germany Class A Statement . . . . . . . . . . . . . . . . . . . . . 69

VCCI Class A Statement . . . . . . . . . . . . . . . . . . . . . . . 70

Japan Electronics and Information Technology Industries Association

(JEITA) Statement. . . . . . . . . . . . . . . . . . . . . . . . . . 70

Korea Communications Commission (KCC) Statement. . . . . . . . . . 71

Russia Electromagnetic Interference (EMI) Class A Statement . . . . . . . 71

People’s Republic of China Class A Electronic Emission Statement . . . . 71

Taiwan Class A Compliance Statement . . . . . . . . . . . . . . . . 71

4

CN4093 10Gb Converged Scalable Switch Installation Guide

Safety Information

Before installing this product, read the Safety Information.

Antes de instalar este produto, leia as Informações de Segurança.

Prije instalacije ovog produkta obavezno pročitajte Surgonosne Upute.

Před instalací tohoto produktu si přečtěte příručku bezpečnostních instrukcí.

Læs sikkerhedsforskrifterne, før du installerer dette produkt.

Lees voordat u dit product installeert eerst de veiligheidsvoorschriften.

Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information.

Avant d'installer ce produit, lisez les consignes de sécurité.

Vor der Installation dieses Produkts die Sicherheitshinweise lesen.’

Πριν εγκαταστήσετε το προϊόν αυτό, διαβάστε τις Πληροφορίες ασφαλείας

(safety information).

A termék telepítés előtt olvassa el a Biztonsági előírásokat!

Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza.

Πред да инсталира овој продукт, прочитајте информацијата за безбедност.

© Copyright Lenovo 2016

Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet.

Przed zainstalowaniem tego produktu, należy zapoznać się z książką “Informacje dotyczace bezpieczeństwa” (Safety Information).

Antes de instalar este produto, leia as Informações sobre Segurança.

Перед установкой продукта прочтитe инcтрyкции по тexникe безопасности.

Pred inštaláciou tohto zariadenia si prečítajte Bezpečnostné predpisy.

Safety Information

5

Pred namestitvijo tega proizvoda preberite Varnostne informacije.

Antes de instalar este producto, lea la información de seguridad.

Läs säkerhetsinformationen innan du installerar den här produkten.

Bu ürünü kurmadan önce güvenlik bilgilerini okuyun.

Youq mwngz yungh canjbinj neix gaxgonq, itdingh aeu doeg aen canjbinj soengq cungj vahgangj ancien suisik.

6

CN4093 10Gb Converged Scalable Switch Installation Guide

Safety Statements

Important—

Each caution and danger statement in this document is labeled with a number. This number is used to cross reference the English-language caution or danger statement with the translated versions of the caution or danger statement in the

Safety Information document.

For example, if a caution statement is labeled “Statement 1,” translations for that caution statement are in the Safety Information document under “Statement 1.”

Be sure to read all caution and danger statements in this document before you perform the procedures. Read any additional safety information that comes with the system or optional device before you install the device.

Following is a compilation of the statements found throughout this manual.

Statement 1

DANGER

© Copyright Lenovo 2016

Electrical current from power, telephone, and communication cables is hazardous.

To avoid a shock hazard:

Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm.

Connect all power cords to a properly wired and grounded electrical outlet.

Connect to properly wired outlets any equipment that will be attached to this product.

When possible, use one hand only to connect or disconnect signal cables.

Never turn on any equipment when there is evidence of fire, water, or structural damage.

Disconnect the attached power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures.

Connect and disconnect cables as described in the following table when installing, moving, or opening covers on this product or attached devices.

To Connect: To Disconnect:

1. Turn everything OFF.

2. First, attach all cables to devices.

3. Attach signal cables to connectors.

4. Attach power cords to outlet.

5. Turn device ON.

1. Turn everything OFF.

2. First, remove power cords from outlet.

3. Remove signal cables from connectors.

4. Remove all cables from devices.

Safety Information

7

Statement 3

CAUTION:

When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following:

Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device.

Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure.

DANGER

Some laser products contain an embedded Class 3A or Class 3B laser diode.

Note the following.

Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam.

Class 1 Laser Product

Laser Klasse 1

Laser Klass 1

Luokan 1 Laserlaite

Appareil À Laser de Classe 1

Statement 25

CAUTION:

This product contains a Class 1M laser. Do not view directly with optical instruments.

UL Regulatory Information

This device is for use only with listed Lenovo Flex System Enterprise Chassis.

8

CN4093 10Gb Converged Scalable Switch Installation Guide

Chapter 1. The CN4093 10Gb Converged Scalable Switch

This Installation Guide provides information about the Lenovo® Flex System™

Fabric CN4093 10Gb Converged Scalable Switch (referred to as CN4093 or

“switch” throughout this document).

Figure 1. The CN4093

SFP+ module ports

QSFP+ module ports

Omni Ports

Tx/Rx

Link

13

Tx/Rx

Link

14

Link

11

Tx/Rx

Link

12

Tx/Rx

Link

15

Tx/Rx

Link

16

Tx/Rx

Tx/Rx

Link

19

Tx/Rx

Link

20

Link

17

Tx/Rx

Link

18

Tx/Rx

Link

21

Tx/Rx

Link

22

Tx/Rx

Link

3

Tx/Rx

4

10Gb

3 4

5 6

40Gb

3

Link

5

7

Tx/Rx

Link

Tx/Rx

6

8

Link

9

Tx/Rx

10

10Gb

7 8

9 10

40Gb

7

Link

1

Tx/Rx

Link

2

Tx/Rx

RS-232 serial port

(management only)

RJ-45 external management port

Switch status LEDs

Link

Mgmt

Tx/Rx

Note: The illustrations in this document might differ slightly from your hardware.

© Copyright Lenovo 2016

9

The CN4093 provides support for Layer 2 and Layer 3 switching, as well as a full set of converge features:

 Converged Enhanced Ethernet (CEE) including Fibre Channel over Ethernet

(FCoE) over all Ethernet ports, including Omni Ports acting in Ethernet mode.

 Priority-based Flow Control (PFC), Enhanced Transmission Selection (ETS) and

Data Center Bridging Capability Exchange (DCBX).

 N_Port Virtualization (NPV) Gateway and Full Fabric Fibre Channel Forwarder

(FCF).

 Full fabric Fibre Channel (FC) services, including Name Server and hardware-based Zoning.

 Lenovo Virtual Network Interface Card (vNIC) Virtual Fabric Adapter with

Single Root I/O Virtualization (SR-IOV) capability.

The CN4093 provides pay-as-you-grow scalability. With optional licensing, you can easily and cost-effectively expand the number of available ports.

The base license provides support for the following:

 Single compute node port capability, consisting of fourteen internal 10 Gigabit

Ethernet (GbE) with FCoE and auto-negotiation capability)

 Two external 10 GbE/FCoE Small Form-factor Pluggable Plus (SFP+) ports which also support legacy 1 GbE/FCoE connections

 Six Omni Ports, allowing each port pair to be used as either two 10 GbE/FCoE

SFP+ optical ports or as FC ports independently capable of 4 or 8 Gigabits per second (Gbps)

Additional ports are available with optional licenses. There are two upgrades that

are available for the CN4093 (see “Acquiring Feature Licenses” on page 51

).

Upgrade 1 adds supports for the following:

Fourteen additional internal 10 GbE/FCoE compute node ports

Two external 40 GbE/FCoE Quad Small Form Pluggable Plus (QSFP+) ports, each of which can be optionally used as four 10GbE/FCoE SFP+ ports

Upgrade 2 adds support for the following:

 Fourteen additional internal 10 GbE/FCoE compute node ports

 Six additional Omni Ports

Note: Upgrade 1 and Upgrade 2 are independent and can be installed in any order, with or without the other.

SFP+ ports can be populated with 10 Gb optical or copper SFP+ transceiver modules or Direct-Attach Cables (DACs), or legacy 1 Gb optical or copper SFP transceiver modules.

Omni ports ports can be populated with 10 Gb optical SFP+ transceiver modules or

DACs.

QSFP+ ports can be populated with optical QSFP+ modules or DACs, including some that accept SFP+ or SFP modules.

10

CN4093 10Gb Converged Scalable Switch Installation Guide

In addition to port flexibility, you can manage and configure the CN4093 through the following interfaces:

 A Secure Shell (SSH) version 2 or Telnet connection to the embedded

Command-Line Interface (CLI)

 A terminal emulation program connection to the serial port interface

 A network management application using Simple Network Management

Protocol (SNMP)

 A Web browser-based interface (HTTPS/HTTP) connection to the switch

© Copyright Lenovo 2016 Chapter 1: The CN4093 10Gb Converged Scalable Switch

11

Documentation

About this Installation Guide

This Installation Guide provides information and instructions for installing the

CN4093, updating the firmware, and solving problems. For other information about configuration and management of the switch, refer to the documents

described in “Related Documentation” on page 13 .

Note:

 The illustrations in this document might differ slightly from your hardware and might not depict all included labels.

 The console output described or referenced in this document might differ slightly from that displayed by your system. Output varies according to the type of Lenovo chassis and the firmware versions and options that are installed.

Notices and Statements in this Document

The caution and danger statements in this document are also in the multilingual

Safety Information document, which is located at Lenovo System x, ThinkServer and

Storage product documentation . Each statement is numbered for reference to the corresponding statement in the Safety Information document.

The following notices and statements are used in this document:

Note: These notices provide important tips, guidance, or advice.

Important: These notices provide information or advice that might help you avoid inconvenient or problem situations.

Attention: These notices indicate potential damage to programs, devices, or data. An attention notice is placed just before the instruction or situation in which damage could occur.

Caution: These statements indicate situations that can be potentially hazardous to you. A caution statement is placed just before the description of a potentially hazardous procedure step or situation.

Danger: These statements indicate situations that can be potentially lethal or extremely hazardous to you. A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation.

12

CN4093 10Gb Converged Scalable Switch Installation Guide

Related Documentation

Additional or updated product documents may be available from the Lenovo website. Such documents may cover features not described in the original documentation that comes with the switch, or may include technical updates or corrections.

You can obtain up-to-date information on the Lenovo support website: http://support.lenovo.com/

Note: Changes are made periodically to the Lenovo website. Procedures for locating firmware and documentation might vary slightly from what is described in this document.

For information about switch hardware and firmware features, specifications, and standards, including their configuration, see the Application Guide for your specific switch and its installed firmware.

For information about the switch information, statistics, and individual configuration parameters, see the Command Reference for your specific switch and its installed firmware.

See the documentation that came with your Lenovo chassis for information about the environmental conditions and specifications that are supported by the system.

© Copyright Lenovo 2016 Chapter 1: The CN4093 10Gb Converged Scalable Switch

13

14

CN4093 10Gb Converged Scalable Switch Installation Guide

Chapter 2. Installing and Removing the CN4093

This chapter provides instructions for installing and removing the CN4093 in the

Lenovo Flex System chassis. See the documentation for your Lenovo Flex System chassis for information about I/O bay locations and the components that can be installed in them that is specific to your Lenovo Flex System chassis type.

The following illustration shows an example of a Lenovo Flex System chassis

(rear-view) with the I/O bays identified.

Figure 2. Flex System chassis I/O bays.

I/O Module

Bay 1

I/O Module

Bay 3

I/O Module

Bay 2

I/O Module

Bay 4

© Copyright Lenovo 2016

A Lenovo Flex System network adapter must be installed in each compute node with which you want to communicate. To enable the switch to communicate with a compute node, at least one switch must be installed in the Lenovo Flex System chassis. For details about network adapter installation, configuration, and use, see the documentation that comes with the Lenovo Flex System network adapter.

Installing a second switch enables a redundant path and a separate connection from the compute node to the external Ethernet network.

The Lenovo Flex System chassis supports a maximum of four CN4093 modules.

The Lenovo Flex System chassis supports a maximum of twenty-eight network adapters.

15

Note:

I/O bays 1 and 2 support any standard Lenovo Flex System switch or pass-thru module. When you install an I/O network adapter in the left-most fabric connector on the compute node, these I/O bays support any switch with the same type of network interface that is used by the corresponding network adapter.

I/O bays 3 and 4 support any standard Lenovo Flex System switch or pass-thru module. When you install an I/O network adapter in the right-most fabric connector on the compute node, these I/O bays support any switch with the same type of network interface that is used by the corresponding network adapter.

 The compute nodes or Lenovo Flex System chassis that are described or shown in this document might be different from your compute node or Lenovo Flex

System chassis. For additional information, see the documentation that comes with your Lenovo Flex System chassis.

 When the switch is installed in a Lenovo Flex System chassis, the internal ports operate at 1 Gigabits per second (Gbps) or 10 Gbps. The external ports can operate at 1 Gbps, 4 Gbps, 8 Gbps, 10 Gbps, or 40 Gbps, depending on the port type and installed transceiver modules.

16

CN4093 10Gb Converged Scalable Switch Installation Guide

Before Installing the CN4093

Attention: Product information is required in order to register your CN4093, update its firmware, place a service call, or replace the unit.

Some of the product information labels may be hidden from view once the CN4093 is installed. To prevent the need to remove the switch in order to read required product information, locate and record the information shown on Table 1 on page 18 prior to installation.

An example of the product information labels is shown as follows:

Figure 3. Sample product labels from the switch

© Copyright Lenovo 2016

Note: These examples are to help locate and identify the information labels. The actual labels and information for your specific switch may differ.

The identification labels on the CN4093 contain the serial number and part number of the switch. These labels also include the Media Access Control (MAC) address

(on the uppermost handle) of the switch. Though helpful, the MAC address is not required for opening a service call.

Chapter 2: Installing and Removing the CN4093

17

Print this page and record product information below. Keep the information in a safe place for future reference. You will need this information when you register the switch or open a service call with Lenovo.

Table 1.

Important product information

Product Name Lenovo Flex System CN4093 10Gb Converged

Scalable Switch

Serial Number

Part Number

Media Access Control

(MAC) address for switch

MAC addresses for other components

For convenience, once the CN4093 is installed and initialized, you can use the show sys-info command in the switch firmware interface to display the product serial number and other required information.

Installation Guidelines

Before you install the switch in the Lenovo Flex System chassis, read the following information:

Read the safety information that begins on page 5

,

“Handling Static-Sensitive

Devices” on page 19

, and the safety statements in the Lenovo Flex System chassis documentation. This information provides a safe working environment.

 Observe good housekeeping in the area where you are working. Place removed covers and other parts in a safe place.

 Blue on a component indicates touch points, where you can grip the component to remove it from or install it in the compute node or Lenovo Flex System chassis, open or close a latch, and so on.

 Orange on a component or an orange label on or near a component on the switch, compute node, or Lenovo Flex System chassis indicates that the component can be hot-swapped, which means that if the Lenovo Flex System chassis and operating system support hot-swap capability, you can remove or install the component while the Lenovo Flex System chassis is running. (Orange can also indicate touch points on hot-swap components.) See the instructions for removing or installing a specific hot-swap component for any additional procedures that you might have to perform before you remove or install the component.

 You do not have to turn off the Lenovo Flex System chassis to install or replace any of the hot-swap modules on the front or rear of the Lenovo Flex System chassis.

 When you install the switch in the Lenovo Flex System chassis, you must also install a compatible I/O network adapter in the compute node to support the switch.

 When you are finished working on the compute node or Lenovo Flex System chassis, reinstall all safety shields, guards, labels, and ground wires.

18

CN4093 10Gb Converged Scalable Switch Installation Guide

System Reliability Guidelines

To help ensure proper cooling, performance, and system reliability, make sure that the following requirements are met:

 Each of the bays on the rear of the Lenovo Flex System chassis contains either a module or a filler module.

 A removed hot-swap module is replaced with an identical module or filler module within one minute of removal.

 A removed hot-swap compute node is replaced with another compute node or filler node within one minute of removal.

 The ventilation areas on the sides of the compute node are not blocked.

 You have followed the reliability guidelines in the documentation that comes with the Lenovo Flex System chassis.

Handling Static-Sensitive Devices

Attention: Static electricity can damage the switch and other electronic devices. To avoid damage, keep static-sensitive devices in their static-protective packages until you are ready to install them.

To reduce the possibility of electrostatic discharge, observe the following precautions:

 Limit your movement. Movement can cause static electricity to build up around you.

 The use of a grounding system is recommended. For example, wear an electrostatic-discharge wrist strap, if one is available.

 Handle the device carefully, holding it by its edges or its frame.

 Do not touch solder joints, pins, or exposed printed circuitry.

 Do not leave the device where others can handle and damage it.

 While the device is still in its static-protective package, touch it to an unpainted metal part of any unpainted metal surface on a grounded rack component in the rack in which you are installing the device, for at least two seconds. This drains static electricity from the package and from your body.

 Remove the device from its package and install it directly into the switch without setting it down. If it is necessary to set down the device, put it back into its static-protective package. Do not place the device on a switch cover or on a metal surface.

 Take additional care when you handle devices during cold weather. Heating reduces indoor humidity and increases static electricity.

 Some types of Lenovo Flex System chassis come with electrostatic discharge

(ESD) connectors. If your unit is equipped with an ESD connector, see the documentation that comes with the Lenovo Flex System chassis for using the

ESD connector.

© Copyright Lenovo 2016 Chapter 2: Installing and Removing the CN4093

19

Installing the CN4093

Note: The following illustration shows how to install the switch in a Lenovo Flex

System chassis. The appearance of your Lenovo Flex System chassis might be different; see the documentation for your Lenovo Flex System chassis for additional information.

Use the following instructions to install the switch in the Lenovo Flex System chassis. You can install the switch while the Lenovo Flex System chassis is powered on. For redundancy support, you must install I/O modules of the same type in I/O bays 1 and 2, and I/O modules of the same type in bays 3 and 4 of the chassis.

To install the switch, complete the following steps.

1. Read the safety information that begins on

page 5 and

“Installation Guidelines” on page 18 .

2. Select I/O bay in which to install the switch.

Note: For details about I/O bay requirements and bay locations, see the documentation for the Lenovo Flex System chassis.

3. Remove the filler module from the selected bay. Store the filler module for future use.

4. If you have not already done so, touch the static-protective package that contains the switch to an unpainted metal surface of the Lenovo Flex System chassis or an

unpainted metal surface on any other grounded rack-component for at least 2 seconds.

5. Remove the switch from its static-protective package.

6. Make sure that the release levers on the switch are in the open position

(perpendicular to the switch).

7. Slide the switch into the applicable I/O bay until it stops.

20

CN4093 10Gb Converged Scalable Switch Installation Guide

8. Push the release levers on the front of the switch to the closed position. After you insert and lock the switch, it is turned on (there may be a slight delay), and a

Power-On Self-Test (POST) occurs to verify that the switch is operating correctly.

Note: The switch may take up to two minutes to complete the POST. During

POST, the Power LED continuously flashes. Once POST has successfully completed, the Power LED remains on and the Error LED is off.

9. Make sure that LEDs on the switch indicate that it is operating correctly (see

“Information LEDs” on page 34 ).

10. If you have another switch to install, repeat

Step 3 through

Step 9

; otherwise, go to the next step.

11. Install any port transceiver modules or Direct-Attach Cables (DACs) needed for the

switch. For information and instructions, see “Connecting Switch Ports” on page 23 and the documentation that comes with the transceiver modules or DACs.

12. Attach any cables that are required by the switch. For additional information about cabling the switch, see

“Connecting Switch Ports” on page 23 , the documentation

that comes with the port transceiver modules, DACs, cables, and the optional network devices to which the cables are connected.

13. Make sure that the data (non-management) ports on the switch are enabled through the Chassis Management Module (CMM).

© Copyright Lenovo 2016 Chapter 2: Installing and Removing the CN4093

21

Removing or Replacing the Switch

Note: The following illustration shows how to remove and replace the switch from the Lenovo Flex System chassis. The appearance of your Lenovo Flex System chassis might be different; see the documentation for your Lenovo Flex System chassis for additional information.

To replace the switch, complete the following steps.

1. Read the safety information that begins on page 5 , and

“Installation Guidelines” on page 18 .

2. Detach any cables that are attached to the switch you will be removing.

Note: Detaching cables from the switch ports disrupts the network connection from the switch to any connected external devices. If you plan to replace the switch with another switch, you can reuse the existing cables, provided they remains securely attached to the network.

3. Pull the release latches out from the switch. The switch moves out of the bay approximately 0.6 cm (0.25 inch).

4. Slide the switch out of the bay and set it aside in a safe, static-free location.

5. Place either another switch or a filler module in the bay.

Important: Complete this step within 1 minute. For more information, see

“Installing the CN4093” on page 20 .

6. If you placed the switch in the bay, reconnect the ports that you disconnected in

Step 2

and attach any additional cables that are required by the switch.

For additional information about connecting ports, see

“Connecting Switch

Ports” on page 23

, and also the documentation that comes with the port transceiver modules, DACs, cables, and the optional network devices to which the cables have been connected.

22

CN4093 10Gb Converged Scalable Switch Installation Guide

Connecting Switch Ports

The switch includes a variety of external port options. Fixed ports, such as the

RJ-45 management port, can be connected directly by attaching the appropriate cable. Modular ports, such as Small Form-factor Pluggable Plus (SFP+) and Quad

Small Form-factor Pluggable Plus (QSFP+) ports, require the installation of a transceiver module before the cable can be attached. This section covers each supported port type separately:

“The Serial Console Port” on page 23

“The RJ-45 Management Port” on page 24

“SFP+ Ports” on page 26

“QSFP+ Ports” on page 29

Notes:

 The illustrations in this document might differ slightly from your hardware.

 While the information in this section describes the 10 Gigabit Ethernet (GbE)

SFP+ transceiver module, it also applies to the 1 GbE SFP transceiver module.

 The switch supports MSA-compliant copper DACs, up to 5 m (16.5 ft.) in length.

The Serial Console Port

Connecting the Serial Console Cable

To use the serial console, connect a serial cable to the RS-232 serial console port of the switch and the other end of the cable to the console device.

Note: You must use one of the two cables in the Serial Access Cable option.

If your console device uses a standard RS-232 DB9 connector, attach the included mini-USB-to-DB9 serial cable. Otherwise, if your console device uses an RJ-45 connector, attach the included mini-USB-to-RJ-45 serial cable and a user-supplied

RJ-45 adapter cable. Your adapter cable depends on the pin out required by your console device. Pin out of the mini-USB-to-RJ-45 cable is as follows:

Table 2.

Pin out for the included mini-USB-to-RJ-45 cable

PIN # Function Direction

7

8

5

6

3

4

1

2

Not connected

RXD

TXD

GND

GND

Not connected

Not connected

Not connected

In

Out

© Copyright Lenovo 2016 Chapter 2: Installing and Removing the CN4093

23

For additional information, see

“Accessing the Switch Through the Serial-Port

Interface” on page 42

.

Disconnecting the Serial Console Cable

To disconnect the serial console cable, grasp the connector and gently pull the cable from the switch.

The RJ-45 Management Port

Connecting RJ-45 Cables

RJ-45 cables can be connected to the to external management port, and also to SFP+ ports that have legacy 1000BASE-T SFP transceiver modules.

To connect the RJ-45 connector to the switch, push the RJ-45 cable connector into the port connector until it clicks into place.

Disconnecting RJ-45 Cables

To disconnect the RJ-45 cable, squeeze the release tab and gently pull the cable connector out of the switch connector.

24

CN4093 10Gb Converged Scalable Switch Installation Guide

Handling Transceiver Modules

The switch supports the 10 Gb, 8 Gb, and 4 Gb SFP+ module, the 1 GbE SFP module, and the QSFP+ module.

Before you install transceiver modules, read the following information.

The housing of the transceiver modules has an integral guide key that is designed to prevent you from inserting the module incorrectly.

Use minimal pressure when you insert the module into the switch port. Forcing the module into the port can cause damage to the module or port.

You can insert or remove the module while the Lenovo Flex System chassis is turned on.

You must first insert the module into the switch port before you can connect the cables.

You must remove the cable from the transceiver module before you remove the module from the switch port.

Statement 3

CAUTION:

When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following:

Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device.

Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure.

DANGER

Some laser products contain an embedded Class 3A or Class 3B laser diode.

Note the following.

Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam.

Class 1 Laser Product

Laser Klasse 1

Laser Klass 1

Luokan 1 Laserlaite

Appareil À Laser de Classe 1

© Copyright Lenovo 2016 Chapter 2: Installing and Removing the CN4093

25

SFP+ Ports

The switch SFP+ ports accept SFP+ modules that provides two fiber-optic cable connectors for connecting to external devices.

Installing an SFP+ Module

To install an SFP+ module, complete the following steps.

1. Read the safety information that begins on

page 5 and

“Installation Guidelines” on page 18 .

2. If you have not already done so, touch the static-protective package that contains the SFP+ module to an unpainted metal surface of the Lenovo Flex System chassis or an unpainted metal surface on any other grounded rack component in the rack in which you are installing the switch for at least 2 seconds.

3. Read the information in

“Handling Transceiver Modules” on page 25 .

4. Remove the SFP+ module from its static-protective package.

5. If a protective cap is installed in the switch SFP+ port where you are installing the

SFP+ module, remove the cap and store it in a safe place.

6. Remove the protective cap from the SFP+ module and store it in a safe place.

Attention: To avoid damage to the cable or the SFP+ module, make sure that you do not connect the fiber optic cable before the SFP+ module is installed in the switch port.

7. Insert the SFP+ module into the switch SFP+ port until it clicks into place.

SFP+ port

Protective cap

SFP+ module

8. Connect the fiber optic cable (see

“Attaching a Fiber Optic Cable” on page 27 ) and

any cables that you disconnected earlier.

26

CN4093 10Gb Converged Scalable Switch Installation Guide

Attaching a Fiber Optic Cable

Attention: To avoid damage to the fiber optic cable, follow these guidelines:

 Do not route the cable along a folding cable-management arm.

 When you attach the cable to a device on slide rails, leave enough slack in the cable so that it does not bend to a radius of less than 38 mm (1.5 in.) when the device is extended or become pinched when the device is retracted.

 Route the cable away from places where it can be snagged by other devices in the rack.

 Do not overtighten the cable straps or bend the cables to a radius of less than 38 mm (1.5 in.).

 Do not put excess weight on the cable at the connection point. Make sure that the cable is well supported.

To connect the fiber-optic cable to the SFP+ module, complete the following steps.

1. Remove the protective caps from the end of the fiber optic cable.

Fiber-optic cable

Protective cap

2. Gently slide the fiber optic cable into the SFP+ module until it clicks into place.

3. Check the LEDs on the switch. When the switch is operating correctly, the green link LED is lit. For information about the status of the switch LEDs, see

“Locating the Information Panels, LEDs, and External Ports” on page 32 .

Disconnecting a Fiber Optic Cable

To disconnect the fiber optic cable from an SFP+ module, complete the following steps:

1. Squeeze the release tabs and gently pull the fiber optic cable from the module.

2. Replace the protective caps on the ends of the fiber optic cable.

© Copyright Lenovo 2016 Chapter 2: Installing and Removing the CN4093

27

Removing an SFP+ Module

To remove the SFP+ module, complete the following steps.

1. Read the safety information that begins on

page 5 and

“Installation Guidelines” on page 18 .

2. Read the information in

“Handling Transceiver Modules” on page 25 .

3. Remove the fiber optic cable from the module that you want to replace. For more

information about removing the cable, see “Disconnecting a Fiber Optic Cable” on page 27 .

Attention: To avoid damage to the cable or the SFP+ module, make sure that you remove the fiber-optic cable before you remove the module from the switch port.

4. Unlock the SFP+ module by pulling the wire tab straight out, as shown in the following illustration.

5. Grasp the wire tab on the module and pull it out of the switch port.

6. Replace the protective caps on the module and the switch SFP+ port.

7. Place the module into a static-protective package.

28

CN4093 10Gb Converged Scalable Switch Installation Guide

QSFP+ Ports

The QSFP+ ports accept supported QSFP+ modules. The QSFP+ module provides an MTP cable connector for connecting to external devices.

Installing a QSFP+ Module

To install a QSFP+ module in a QSFP+ port on the switch, complete the following steps.

Note: To avoid damage to the cable or the QSFP+ module, do not connect the cable before the QSFP+ module is installed in the switch port.

1. Remove the safety cap from the module and pull the locking lever into the down

(unlocked) position.

2. Insert the QSFP+ module into the switch QSFP+ port until it clicks into place. Use minimal pressure when you insert the module into the port. Do not use excessive force when you insert the module; you can damage the module or the QSFP+ port.

The module has a mechanical guide key to prevent you from inserting the module incorrectly.

3. Pull up the locking lever to lock the module into place.

4. Connect the fiber-optic cable.

Connecting a Fiber Optic Cable

Attention: To avoid damage to the fiber optic cables, follow these guidelines:

 Do not route the cable along a folding cable-management arm.

 When you attach the cable to a device on slide rails, leave enough slack in the cable so that it does not bend to a radius of less than 38 mm (1.5 in.) when the device is extended or become pinched when the device is retracted.

 Route the cable away from places where it can be snagged by other devices in the rack.

 Do not overtighten the cable straps or bend the cables to a radius of less than 38 mm (1.5 in.).

 Do not put excess weight on the cable at the connection point. Make sure that the cable is well supported.

© Copyright Lenovo 2016 Chapter 2: Installing and Removing the CN4093

29

To connect the fiber optic cable to the QSFP+ module, complete the following steps.

1. Remove the protective caps from the end of the fiber optic cable.

Fiber-optic cable

Protective cap

2. Gently slide the fiber optic cable into the QSFP+ module until it clicks into place.

3. Check the LEDs on the switch. When the switch is operating correctly, the green link LED is lit. For information about the status of the switch LEDs, see

“Locating the Information Panels, LEDs, and External Ports” on page 32

.

Disconnecting a Fiber Optic Cable

To disconnect the fiber optic cable from the QSFP+ module, complete the following steps:

1. Squeeze the release tabs and gently pull the fiber optic cable from the module.

2. Replace the protective caps on the ends of the fiber optic cable.

Removing a QSFP+ Module

To remove the QSFP+ module from the switch port, complete the following steps.

1. Read the safety information that begins on

page 5 and

“Installation Guidelines” on page 18 .

2. Read the information in

“Handling Transceiver Modules” on page 25 .

3. Remove the fiber optic cable from the module that you want to replace. For more

information about removing the cable, see “Disconnecting a Fiber Optic Cable” on page 30 .

Attention: To avoid damage to the cable or the module, make sure that you disconnect the fiber-optic cable before you remove the QSFP+ module from the switch port.

30

CN4093 10Gb Converged Scalable Switch Installation Guide

4. Unlock the module by pulling the wire tab straight out, as shown in the following illustration.

5. Grasp the wire tab on the module and pull it out of the port.

6. Replace the protective cap on the module and the switch QSFP+ port.

7. Place the module into a static-protective package.

© Copyright Lenovo 2016 Chapter 2: Installing and Removing the CN4093

31

Locating the Information Panels, LEDs, and External Ports

This section describes the information panels and LEDs on the switch and identifies the external ports on the information panels.

Note: The illustrations in this document might differ slightly from your hardware.

Information Panel

The front panel of the switch contains a variety of ports and information LEDs.

The switch-module information panel contains the following components.

 LEDs that display the following information:

The status of the switch (Power, Locator, and Error)

The status of the external connections to the switch

For further details about LEDs, see

“Information LEDs” on page 34 .

 Two 10 GbE/Fibre Channel over Ethernet (FCoE) SFP+ port connectors for SFP+ transceiver modules or DACs. These connectors are identified as ports EXT1 and

EXT2 in the I/O-module configuration menus and are labeled 1 and 2 (from top to bottom) on the switch.

 Two 40 GbE/FCoE QSFP+ port connectors that can be used as eight 10GbE/FCoE

SFP+ ports. These connectors are identified as ports EXT3 and EXT7 (or EXT3 through EXT6, and EXT7 through EXT10, depending on configuration) in the

I/O-module configuration menus, and are labeled 3 through 10 (from top to bottom) on the switch.

 Twelve Omni Port (SFP+) connectors for SFP+ transceiver modules and DACs for 10GbE or 4/8 Gb Fibre Channel (FC) connections. These connectors are idendified as ports EXT11 through EXT22 in the I/O-module configuration menus, and are labeled 11 through 22 (from top to bottom) on the switch.

 One 9600 baud RS-232 serial port connector for switch console (management) purposes. This connector is located near the bottom of the switch panel, just above the management (Mgmt) port. Do not attach any devices to this connector other than the serial access cable option specified for the switch.

 One 1 Gb Ethernet RJ-45 port connector for switch management purposes. Do not attach any devices to this connector other than when using an industry standard CAT5 cable. This connector is identified as port EXTM in the

I/O-module configuration menus and is labeled Mgmt on the switch.

For additional details, see “Connecting Switch Ports” on page 23 and

“Port Status

LEDs” on page 35 .

32

CN4093 10Gb Converged Scalable Switch Installation Guide

© Copyright Lenovo 2016

Figure 4. The CN4093 front panel

SFP+ module ports

QSFP+ module ports

Omni Ports

Tx/Rx

Link

19

Tx/Rx

Link

20

Link

17

Tx/Rx

Link

18

Tx/Rx

Link

21

Tx/Rx

Link

22

Tx/Rx

Tx/Rx

Link

13

Tx/Rx

Link

14

Link

11

Tx/Rx

Link

12

Tx/Rx

Link

15

Tx/Rx

Link

16

Tx/Rx

Link

3

Tx/Rx

4

10Gb

3 4

5 6

40Gb

3

Link

5 6

Tx/Rx

Link

7

Tx/Rx

8

Link

9

Tx/Rx

10

10Gb

7 8

9 10

40Gb

7

Link

1

Tx/Rx

Link

2

Tx/Rx

RS-232 serial port

(management only)

RJ-45 external management port

Switch status LEDs

Link

Mgmt

Tx/Rx

Chapter 2: Installing and Removing the CN4093

33

Information LEDs

The front panel of the switch has LEDs for system and port status. The Power,

Locator, and Error LEDs indicate the switch status. The Link (LINK) and Activity

(TX/RX) LEDs indicate the status of the external ports.

Notes:

A yellow LED on the Lenovo Flex System chassis is lit when a system error or event has occurred. To identify the error or event, check the Lenovo Flex System management-module event log or the switch system log.

During POST, the switch Power LED continuously flashes. Additionally, all of the switch status LEDs and the licensed Port LEDs are lit as a visual indication they are working. Once POST has successfully completed, the switch Power

LED remains on and the switch Error LED is off.

Any errors that are detected during POST are written to the system log. For information about the command to read the system log, see the Command Reference for the switch.

When POST errors are written to the system log, these errors are also written to the

Lenovo Flex System management-module event log. If a hardware error, such as a current fault occurs, the CMM displays it. If a firmware error occurs, the CMM displays the

Module did not complete POST message and a post error code that indicates the test that was running when the error was detected.

Note: You can also use the CMM to make sure that the switch is operating correctly. For more information, see the CMM documentation.

34

CN4093 10Gb Converged Scalable Switch Installation Guide

Switch Status LEDs

The following table provides descriptions of the switch status LEDs on the front panel of the switch.

Table 3.

System status LEDs behavior

LED State Functional Meaning

- Power Steady green

When lit, this LED indicates that the switch is on.

- Locator

- Error

Off

Steady blue

Off

Steady yellow

Off

When this LED is off and the yellow Error LED is lit, it indicates a critical alert.

If both the Power and Error LEDs are off, it indicates that the switch is off.

When prompted by a user action in the CMM, this

LED is lit to help identify the location of the switch.

The switch has not received a user-prompted locator command from the CMM.

When lit, this LED indicates a POST failure or critical alert. As a result, the system-error LED on the Lenovo Flex System chassis is also lit.

When this LED is off and the green Power LED is lit, it indicates that the switch is working correctly.

If both the Power and Error LEDs are off, it indicates that the switch is off.

Port Status LEDs

The following table provides descriptions of the port status LEDs on the front panel of the switch.

Table 4.

System status LEDs behavior

LED State Functional Meaning

Link

Tx/Rx

Mode

Steady green A connection (or link) is established between the corresponding port and the attached device.

Off

Flashing green

Off

There is no signal on the corresponding port, or the link is down.

The corresponding port link is transmitting and/or receiving.

There is currently no traffic on the port.

Steady green

Off

The port pair is configured for FC mode.

The port pair is configured for Ethernet mode.

Flashing green One or both attached devices are not compatible with the configured mode (FC or Ethernet) for the port pair.

© Copyright Lenovo 2016 Chapter 2: Installing and Removing the CN4093

35

36

CN4093 10Gb Converged Scalable Switch Installation Guide

Chapter 3. Configuring the CN4093

The switch has an internal Ethernet path to the Chassis Management Module

(CMM), the external Ethernet data ports, an external management port, and a serial console port. The switch supports two remote-access modes for management through Ethernet connections. You can select the mode that is best suited for your

Lenovo Flex System environment.

Default mode: The default mode uses the internal path to the CMM only. In this mode, the remote-access link to the management console must be attached to the

Ethernet connector on the CMM. The Internet Protocol (IP) addresses and

Simple Network Management Protocol (SNMP) parameters of the switch can be automatically assigned by the Lenovo Director Flex System Deployment wizard

(when available), or you must assign them through the Lenovo Flex System

Management and Configuration program. This mode enables you to provide a secure LAN for management of the Lenovo Flex Systems subsystems that is separate from the data network. See

“Establishing an Interface Through the

CMM” on page 39

for more information.

External management mode: External management mode allows for the use of alternate management entities to control and configure the switch. You must enable external management in order to manage the switch using the dedicated external management port (EXTM) or any of the external data ports

(EXT1-EXT22, in-band switch management). This mode can be used instead of or in addition to access through the CMM. This mode can be enabled only through the CMM configuration interface. When this mode is enabled, the external ports support both management and data traffic.

This mode enables the use of additional switch IP addresses on different IP subnets than the CMMs. This is useful when the switches are to be managed and controlled as part of the overall network infrastructure, while secure management of other Lenovo Flex System subsystems is maintained through

the CMM. See “Enabling Management Through Data Ports” on page 40 for

additional instructions about configuring the switch for this mode of operation.

The RS-232 console port provides an alternative path to manage and configure the switch for local access.

Important:

 Before you configure the switch, make sure that the CMM is correctly configured. For more information about configuring the CMM, see the following documents:

– Lenovo Flex System Chassis Management Module Installation Guide

– Lenovo Flex System Chassis Management Module User’s Guide

 The initial default IP address assigned to the switch by the CMM is

192.168.70.120, 192.168.70.121, 192.168.70.122, or 192.168.70.123 depending on the bay where the switch is installed.

 If you change the IP address of the switch and restart the Lenovo Flex System chassis, the switch maintains this new IP address as its default value.

 The CMM and the switch can communicate with each other only if they are on the same IP subnet.

© Copyright Lenovo 2016

37

 When configuring the switch, you must execute the copy running-config startup-config command if you want the configuration change to persist beyond the next reboot of the switch. This command stores the current switch configuration and all changes in nonvolatile memory.

If the switch restarts and the CMM cannot apply the saved configuration, the switch defaults to the configuration that was previously saved. If the IP subnet address of the switch does not match the IP subnet address of the CMM, you can no longer manage the switch from the CMM. For more information about configuring the switch, see the Command Reference for your specific switch and its installed firmware.

 When you use the management-module Web interface to update the switch configuration, the management-module firmware saves the new configuration in internal nonvolatile memory. If the switch restarts, the CMM applies the saved configuration to the switch. For more information, see the Application

Guide and the Command Reference for your specific switch and its installed firmware.

 For switch communication with a remote management station, such as an

Lenovo Director management server, through the management-module external

Ethernet port, the switch internal-network interface and the management-module external interface must be on the same IP subnet.

For specific details about configuring the switch and preparing for system installation, see the documentation listed in

“Related Documentation” on page 13

.

Notes:

 Unless otherwise stated, references to the CMM apply only to the Lenovo Flex

System Chassis Management Module, which is the only type of management module that supports the switch.

 Throughout this document, the management-module Web-based user interface is also known as the Lenovo Flex System management-module Web interface.

 Throughout this document, the user name is also known as the login name or user ID for logging on to interfaces or programs.

 The screens that are described or referenced in this document might differ slightly from the screens that are displayed by your system. Screen content varies according to the type of Lenovo Flex System chassis and the firmware versions and options that are installed.

38

CN4093 10Gb Converged Scalable Switch Installation Guide

Establishing an Interface Through the CMM

For remote management functions, the switch requires a TCP/IP interface. This can be configured through the CMM as follows:

1. Log on to the CMM Command-Line Interface (CLI) as described in the CMM documentation. If necessary, obtain the IP address of the CMM from your system administrator.

Note: The default User ID for the CMM is USERID, and the default password is

PASSW0RD (where the sixth character is the number zero, not the letter

O). The User ID and password fields are case-sensitive.

2. Set the environment to the bay where you installed the switch: system> env -T system:switch[1]

3. Execute the ifconfig command to configure the IP parameters you wish to use for remote switch management. For example,

ifconfig -i 192.168.70.1 -s 255.255.255.0 -g 192.168.70.100

where the

-i parameter is the IPv4 address, -s is the subnet mask, and -g is the default gateway.

4. You should now be able to ping the switch from the CMM using this address: system:switch[1]> ping -i 192.168.70.1

Reply from 192.168.70.1: bytes=64 time=0.198ms

Reply from 192.168.70.1: bytes=64 time=0.213ms

Reply from 192.168.70.1: bytes=64 time=0.228ms

Reply from 192.168.70.1: bytes=64 time=0.168ms

One the switch management address is configured, you can use it to establish a

Secure Shell (SSH)/Telnet session or Web session (HTTPS/HTTP) .

Note: SSH and HTTPs are enabled by default. Telnet and HTTP can be enabled once you have initially logged into the switch.

The Web interface application and the SSHv2/Telnet client software provide different ways to access the same internal-switching firmware and configure it.

If your system application requires that you use the Web interface application, see

“Accessing the Switch Through the Browser-Based Interface” on page 43

for additional information.

If your system application requires that you use the SSHv2/Telnet client software, see

“Accessing the Switch Through the SSHv2/Telnet Interface” on page 41 for

additional information.

© Copyright Lenovo 2016 Chapter 3: Configuring the CN4093

39

Enabling Management Through Data Ports

To access and manage the switch through external interfaces, you must enable the data (non-management) ports and the ability to manage the switch through them.

Use the information in the following table to configure your ports.

Data Ports

(-ep option)

Disabled

Enabled

Disabled

Enabled

External Mgmt

(-em option)

Disabled

Description

Disabled

Enabled

Enabled

The switch must be managed through the

CMM. No traffic is allowed on internal or external switch ports.

The switch must be managed through the

CMM. Data traffic is allowed on internal and external switch ports.

The switch can be managed through the CMM or a compute node. No traffic is allowed on internal or external switch ports.

The switch can be manage through the CMM, a compute node, or a management station that is connected through the swtich. Data traffic is allowed on internal and external switch ports.

To enable management through data ports, complete the following steps:

1. Log on to the CMM CLI as described in the CMM documentation. If necessary, obtain the IP address of the CMM from your system administrator.

2. Set the environment to the bay where you installed the switch: system> env -T system:switch[1]

3. Execute the ifconfig command to enable data ports and external management:

ifconfig -ep enabled -em enabled

4. You should now be able to manage the switch using its data ports or external management port.

Note: “External management” refers to means other than by the CMM. To externally manage the switch, additional IP interfaces must be configured. For more information see the Application Guide for your specific switch and its installed firmware.

40

CN4093 10Gb Converged Scalable Switch Installation Guide

Accessing the Switch Through the SSHv2/Telnet Interface

The switch supports a Command-Line Interface (CLI) that you can use to configure and control the switch over the network through the SSHv2/Telnet client software.

You can use the CLI to perform many basic network-management functions. In addition, you can configure the switch for management through an SNMP-based network-management system.

If you know the IP address for the switch ( “Establishing an Interface Through the

CMM” on page 39

) and you have an existing network connection, you can use the

SSHv2/Telnet client software from an external management station to access and control the switch. Optimally, the management station and the switch should be on the same subnet. Otherwise, you must use a router and configure a gateway address on the switch. If you have to obtain the IP address for the switch or establish a network connection, contact your system or network administrator.

The switch also supports user-based security that enables you to prevent unauthorized users from accessing the switch or changing its settings.

To connect to the switch through the SSHv2/Telnet interface, refer to your client software for specific instructions on how to invoke a session. For example, using the Microsoft Telnet Client, you would complete the following steps:

1. From a DOS command-line prompt, type telnet <switch IP address> and press

Enter.

2. When prompted, enter your user name and password.

When logging in to a switch for the first time, the default switch administrator user name is

USERID, and the default password is PASSW0RD (where the sixth character is the number zero, not the letter O). The User ID and password fields are case-sensitive. For security purposes, you will be prompted to change the administrator password after the first successful login.

Otherwise, if you have an assigned user account, use your assigned user name and password.

Important: Any configuration changes made using the management interfaces will be lost during the next switch reboot unless you execute the copy running-config startup-config command. This command stores the current switch configuration and all changes in nonvolatile memory.

For more information about configuring through the CLI, see the Application Guide and Command Reference for your specific switch and its installed firmware.

© Copyright Lenovo 2016 Chapter 3: Configuring the CN4093

41

Accessing the Switch Through the Serial-Port Interface

The serial port provides basic communication RS-232 serial-data transfer through a terminal emulation program (such as Hyperterminal). Because messages from the power-on self-test (POST) and all initialization information are transmitted through the serial port, you can use the serial port to log in to the switch and access and configure the internal switching firmware.

To log in to the switch, complete the following steps:

1. Connect one end of the specifically designed serial cable that comes with your device into the RS-232 port and connect the other end to the management station.

For additional information, see

“Connecting the Serial Console Cable” on page 23

.

2. On the management station, open a console window and make sure that the serial port is configured with the following settings:

9600 baud

8 data bits

No parity

1 stop bit

No flow control

3. When prompted, enter your user name and password.

When logging in to a switch for the first time, the default switch administrator user name is

USERID, and the default password is PASSW0RD (where the sixth character is the number zero, not the letter O). The User ID and password fields are case-sensitive. For security purposes, you will be prompted to change the administrator password after the first successful login.

Otherwise, if you have an assigned user account, use your assigned user name and password.

The serial port is compatible with the standard 16550 Universal Asynchronous

Receiver/Transmitter (UART) protocol. The RS-232 serial port is enabled by default.

42

CN4093 10Gb Converged Scalable Switch Installation Guide

Accessing the Switch Through the Browser-Based Interface

Before you can access and start the browser-based interface, make sure that you have completed the following procedures:

 Configure at least one IP interface on the switch. Refer to

“Establishing an

Interface Through the CMM” on page 39

for more information.

 Enable frames and the JavaScript program in your Web browser.

The following hardware and software are required for the Web interface:

 A frame-capable Web-browser program, such as Internet Explorer (version 7.0 or later), Mozilla Firefox (version 8.0 or later), or Google Chrome (version 16.0 or later)

 A computer or workstation with network access to the switch

To start the browser-based interface, complete the following steps:

1. Start a Web browser. The Web-browser window opens.

2. In the URL field, enter the IP address of the switch, in the following format:

https://xxx.xxx.xxx.xxx.

The login window opens.

3. When prompted, enter your user name and password and click OK.

When logging in to a switch for the first time, the default switch administrator user name is

USERID, and the default password is PASSW0RD (where the sixth character is the number zero, not the letter O). The User ID and password fields are case-sensitive. For security purposes, you will be prompted to change the administrator password after the first successful login.

Otherwise, if you have an assigned user account, use your assigned user name and password.

© Copyright Lenovo 2016 Chapter 3: Configuring the CN4093

43

Initial Configuration

The operating firmware on the switch contains default configuration files that are installed during the firmware installation. These initial configuration settings are not in a separate configuration file but are components of the firmware. When you restore the switch to factory defaults, the original configuration is restored.

After you log on to the switch, you must perform basic configuration tasks. For more information about configuring and managing the switch, see the Application

Guide and Command Reference for your specific switch and its installed firmware.

44

CN4093 10Gb Converged Scalable Switch Installation Guide

Chapter 4. Updating the Firmware and Licensing

This chapter describes how to determine the level of the firmware that is installed on the switch, how to obtain the latest level of switch firmware, how to upgrade the firmware, how to acquire additional feature licenses, and how to reset the switch to activate the firmware upgrade.

Note: Configuration settings may be lost during some firmware updates. Before updating the firmware, save a copy of the configuration on a separate device. In the event of a failed update, the saved configuration can be restored. For more information about the configuration file, see the Application Guide and Command

Reference for your specific switch and installed firmware.

© Copyright Lenovo 2016

45

Determining the Level of Switch Firmware

After you install the switch in the Lenovo Flex System chassis, make sure that the latest firmware is installed on the switch. To determine the level of the firmware that is installed, complete the following steps.

1. Log on to the Lenovo Flex System Chassis Management Module (CMM)

Command-Line Interface (CLI) as described in the CMM documentation. If necessary, obtain the Internet Protocol (IP) address of the CMM from your system administrator.

2. Set the environment to the bay where you installed the switch. For example: system> env -T system:switch[1]

3. Execute the info command to display switch firmware information: system:switch[1]> info

...

Boot ROM

Rel date: 04/02/2013

Version: 7.7.1.12

Status: Active

Main application

Rel date: 04/02/2013

Version: 7.7.1.12

Status: Active

Main application

Rel date: 03/22/2013

Version: 7.7.1.12

Status: Inactive

46

CN4093 10Gb Converged Scalable Switch Installation Guide

Obtaining the Latest Level of Switch Firmware

If firmware updates are available, you can download them from the Lenovo website: http://support.lenovo.com/

Note: Changes are made periodically to the Lenovo website. Procedures for locating firmware and documentation might vary slightly from what is described in this document.

Attention:

 Before updating the firmware, save a copy of the configuration to a separate device. In the event of a failed update, the saved configuration can be restored.

For more information about the configuration file, see the Application Guide and

Command Reference for your specific switch and firmware version.

 Installing the incorrect firmware might cause the switch to malfunction. Before you install firmware, read any release notes, readme files and change history files that are provided with the downloaded update. These files contain important information about the update and the procedure for installing the update, including any special procedure or requirements for updating from an early firmware version to the latest version.

© Copyright Lenovo 2016 Chapter 4: Updating the Firmware and Licensing

47

Upgrading the Switch Firmware

You can upgrade the switch firmware by using an FTP, TFTP or SFTP file server.

Typically, the file server runs as an application under your operating system. Make sure that the file server application is installed on your file server; then, download the switch firmware images from the Lenovo website into a directory on your file server. Then enable the file server and set its default directory to the directory where the switch firmware image resides.

Note: Updating the firmware involves rebooting the switch. If you have made any configuration changes you wish to persist beyond the upgrade process, you must type the copy running-config startup-config command. This command stores the current switch configuration and all changes to nonvolatile memory.

To transfer the switch firmware image files from the FTP, TFTP or SFTP file server to the switch, you can establish a Secure Shell (SSH) v2 or Telnet session through the CMM. Ping the file server to make sure that you have a connection. The session performs optimally if all three network entities (file server, CMM, and switch IP addresses) are on the same subnet. Otherwise, you must use a router and configure a gateway address on the switch. Use the management-module interface to configure the IP addresses of the CMM external interface (eth0) and the switch so that they are both on the same subnet as the file server.

Examples of IP addresses and masks are described in the following table.

Network entity

FTP, TFTP or SFTP file server

CMM (eth0)

Switch-module current

IP configuration (IF 128)

IP address

192.168.2.178

192.168.2.237

192.168.2.51

Mask

255.255.255.0

255.255.255.0

255.255.255.0

Note: With this configuration, you can ping the switch from the file server.

48

CN4093 10Gb Converged Scalable Switch Installation Guide

Switch Firmware Upgrade Example

To upgrade the switch firmware, complete the following steps.

1. Log in to the switch (see

“Configuring the CN4093” on page 37

for more information).

2. At the switch Command-Line Interface (CLI) prompt, execute the following commands to upload the firmware image to the switch.

CN 4093> enable

CN 4093# copy {ftp|tftp|sftp} {image1|image2} addr <server address> file

<image file>

{data-port|extm-port|mgt-port}

Where server address is the IP address of file server, and image file is the file name of the firmware image as it appears in the file server operating-system.

3. Execute the following command to upload the boot image to the switch.

CN 4093# copy {ftp|tftp|sftp} boot addr <server address> file <boot file>

{data-port|extm-port|mgt-port}

Where boot file is the file name of the boot image as it appears in the file server operating-system.

4. Reset and restart the switch as described in

“Resetting and Restarting the Switch” on page 50

.

© Copyright Lenovo 2016 Chapter 4: Updating the Firmware and Licensing

49

Resetting and Restarting the Switch

To activate the new image or images, you must reset the switch. To reset the switch, complete the following steps:

1. Log on to the CMM CLI as described in the CMM documentation. If necessary, obtain the IP address of the CMM from your system administrator.

2. Set the environment to the bay where you installed the switch. For example: system> env -T system:switch[1]

3. Execute the reset command to restart the switch: system:switch[1]> reset

4. Wait for the POST to complete. This may take up to 2 minutes.

5. Execute the info command for the switch that was just restarted and note the corresponding level of the firmware for the switch. Confirm that the firmware build number reflects the correct firmware release. For example: system:switch[1]> info

...

Boot ROM

Rel date: 01/18/2015

Version: 7.11.0.0

Status: Active

Main application

Rel date: 01/18/2015

Version: 7.11.0.0

Status: Active

Main application

Rel date: 01/18/2015

Version: 7.11.0.0

Status: Inactive

50

CN4093 10Gb Converged Scalable Switch Installation Guide

Acquiring Feature Licenses

The base license provides support for a single compute node of fourteen internal 10

Gigabit Ethernet (GbE)/Fibre Channel over Ethernet (FCoE) ports, two external 10

GbE/FCoE Small Form Pluggable Plus (SFP+) ports, and six Omni Ports which can be used either for 10 GbE/FCoE or 4/8 Gigabits per second (Gbps) Fibre Channel

(FC) connections. Additional ports are available with optional licenses. There are two upgrades that are available for the CN4093.

Upgrade 1 adds supports for the following:

 Fourteen additional internal 10 GbE/FCoE compute node ports

 Two external 40 GbE/FCoE Quad Small Form Pluggable Plus (QSFP+) ports, which can be used as eight 10GbE/FCoE SFP+ ports

Upgrade 2 adds support for the following:

 Fourteen additional internal 10 GbE/FCoE compute node ports

 Six additional Omni Ports allowing the same port to be used either as a 10

GbE/FCoE SFP+ port or as a 4 Gbps or 8 Gbps FC port

Note: Upgrade 1 and Upgrade 2 are independent and can be installed in any order, with or without the other.

Upgrade licenses are unique to each switch and are non transferable.

To acquire an upgrade license activation key, purchase the Authorization Code and locate the unique ID (UID) on the switch serial number (SN) label (bottom or rear of switch module). The UID is the last twelve characters of the switch serial number. This serial number is located on the part number (PN) label (bottom or rear of switch module) and is also displayed during a login to any of the user interfaces. For example, SN (UID): Y250CM294998. For more information about

locating the switch identification labels, see “Before Installing the CN4093” on page 17

.

In the event of the switch replacement, new activation key files based on the serial number of the replacement unit must be acquired and installed. If the replacement is handled through Lenovo Service and Support, your original Authorization Code is transferred to the serial number of the replacement unit.

You can use the Lenovo website to perform the following tasks:

 Request a new activation key

 Check an authorization code to see what feature it enables and how many remaining times it can be used to create a key

 Retrieve the history of feature activation on a selected device

 Retrieve the history of feature activation on a selected authorization code

 Retrieve a lost authorization code

 Manage your Lenovo customer number

 Find help for the Features on Demand feature activation process

 Provide feedback to Lenovo about the Features on Demand process

© Copyright Lenovo 2016 Chapter 4: Updating the Firmware and Licensing

51

Note: Your Lenovo ID and password are required to log into the Features on

Demand website.

52

CN4093 10Gb Converged Scalable Switch Installation Guide

Installing Feature Licenses

Once Features on Demand activation key files have been acquired, they must be installed on the switch. The example below illustrates use of the switch CLI, but other interfaces may also be used, such as the Browser Based Interface (BBI), or

Simple Network Management Protocol (SNMP). For more information, see the

Application Guide and Command Reference for your specific switch and its installed firmware.

When installing licenses, please note the following requirements:

 A switch reboot is required to fully activate the license(s). If you have made any configuration changes you wish to persist beyond the reboot, you must execute the copy running-config startup-config command. This command stores the current switch configuration and all changes to nonvolatile memory.

 Both license key files can be installed prior to the switch reset in order to activate both at the same time.

Complete the following steps to install feature licenses:

1. Log in to the switch (see

“Configuring the CN4093” on page 37

for more information).

2. At the switch CLI prompt, type the following command.

CN 4093> enable

CN 4093# software-key

CN 4093(Software-Key)# enakey addr <server address> keyfile <file name> protocol

{tftp|sftp} {data-port|extm-port|mgt-port}

where server address is the IP address of the TFTP or SFTP file server, and file

name is the name of the licence key file as it appears in the file server operating system.

3. Once the key file transfer is complete, reset the switch to activate the license(s) (see

“Resetting and Restarting the Switch” on page 50

).

© Copyright Lenovo 2016 Chapter 4: Updating the Firmware and Licensing

53

54

CN4093 10Gb Converged Scalable Switch Installation Guide

Chapter 5. Solving Problems

This section provides basic troubleshooting information to help you solve some problems that might occur while you are setting up the switch. The Application

Guide for the switch provides more details about troubleshooting the switch.

If you cannot locate and correct a problem by using the information in this section, see

“Getting Help and Technical Assistance” on page 59 .

© Copyright Lenovo 2016

55

Running POST

To ensure that it is fully operational, the switch processes a series of tests during power-up or a restart (Power-On Self-Test, or POST). These tests may take up to two minutes to complete. The Lenovo Flex System Chassis Management Module

(CMM) reads the test results and displays them for you. During normal operation, these tests are completed without error, and the green switch Power LED is lit.

However, if the switch fails POST, the yellow Error LED on the switch and the system-error LED on the chassis are lit. An event is stored in the event log in the system status panel of the CMM. The specific failure is displayed on the system status I/O module panel of the CMM.

Note: For the locations and descriptions of the switch LEDs, see

“Locating the

Information Panels, LEDs, and External Ports” on page 32

.

56

CN4093 10Gb Converged Scalable Switch Installation Guide

POST Errors

There are two types of errors: noncritical and critical. A noncritical error applies to one port, and the switch is operational. You can continue to operate the switch; however, you must replace it as soon as possible. When critical errors occur, the switch does not operate.

To view POST results, complete the following steps:

1. Log on to the CMM Command-Line Interface (CLI) as described in the CMM documentation. If necessary, obtain the Internet Protocol (IP) address of the CMM from your system administrator. The login window opens.

2. Turn off the power to the switch; then, turn it on again.

3. After POST is completed, the CMM displays the results. Refresh the window to view the POST results. If a critical error occurs, replace the switch. If a noncritical error occurs, see the switch error log for additional details.

The following table describes the basic critical and noncritical failures. This abbreviated list is representative; it is not an exhaustive list. An error code is associated with each failure. Error codes are displayed on the CMM Switch

Information window. Be sure to note the applicable error code and corresponding failure. You might have to provide this information when you call for service. For

details, see “Getting Help and Technical Assistance” on page 59 .

Diagnostic indicator (in hex)

Failing functional area

00–7F

80–9F

A0–AF

B0–FE

FF

Base internal functions

Internal interface failures

External interface errors

Reserved

Switch “good” indicator

Failure criticality

Critical

Noncritical

Noncritical

Noncritical

Operation

© Copyright Lenovo 2016 Chapter 5: Solving Problems

57

Parts listing

The following replaceable components are available for the Lenovo Flex System network devices.

Replaceable components are of three types:

Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1CRU at your request, you will be charged for the installation.

Tier 2 customer replaceable unit (CRU): You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for your server.

Field replaceable unit (FRU): FRUs must be installed only by trained service technicians.

For information about the terms of the warranty, see the Warranty Information document.

The replaceable components in the following table are Tier 1 CRUs. If other components require replacement, see the documentation that came with those devices for instructions.

The following table lists the replaceable components.

Description

Lenovo Flex System Fabric CN4093 10Gb Converged

Scalable Switch

CRU part number (Tier 1)

00VX275

58

CN4093 10Gb Converged Scalable Switch Installation Guide

Appendix A. Getting Help and Technical Assistance

If you need help, service, or technical assistance or just want more information about Lenovo products, you will find a wide variety of sources available from

Lenovo to assist you. This appendix will help you obtain additional information about Lenovo and Lenovo products, and determine what to do if you experience a problem with your Lenovo system or optional device.

Note: This section includes references to IBM web sites and information in regard to obtaining service. IBM is Lenovo's preferred service provider for the System x,

Flex System, and NeXtScale System products.

You can solve many problems without outside assistance by following the troubleshooting procedures that Lenovo provides in the online help or in the

Lenovo product documentation. The Lenovo product documentation also describes the diagnostic tests that you can perform. The documentation for most systems, operating systems, and programs contains troubleshooting procedures and explanations of error messages and error codes. If you suspect a software problem, see the documentation for the operating system or program.

Before you call, make sure that you have taken these steps to try to resolve the problem yourself.

 Check all cables to make sure that they are connected.

 Check the power switches to make sure that the system and any optional devices are turned on.

 Check for updated software, firmware and operating-system device drivers for your Lenovo product. The Lenovo Warranty terms and conditions state that you, the owner of the Lenovo product, are responsible for maintaining and updating all software or firmware for the product (unless it is covered by an additional maintenance contract). Your service technician will request that you upgrade your software or firmware if the problem has a documented solution within a software or firmware upgrade.

 If you have installed new hardware or software in your environment, check the

IBM ServerProven website to make sure that the hardware and software is supported by your product.

 Go to the IBM Support portal to check for information to help you solve the problem, and for other support options.

© Copyright Lenovo 2016

59

 If you believe that you require warranty service for your Lenovo product, gather the following information to provide to the service technician. This data will help the service technician quickly provide a solution to your problem and ensure that you receive the level of service for which you might have contracted.

The service technicians will be able to assist you more efficiently if you prepare before you call.

Hardware and Software Maintenance agreement contract numbers, if applicable

Model number

Serial number

Current system UEFI and firmware levels

Other pertinent information such as error messages and logs

60

CN4093 10Gb Converged Scalable Switch Installation Guide

Appendix B. Notices

Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your local Lenovo representative for information on the products and services currently available in your area.

Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any

Lenovo intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any other product, program, or service.

Lenovo may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:

Lenovo (United States), Inc.

1009 Think Place - Building One

Morrisville, NC 27560

U.S.A.

Attention: Lenovo Director of Licensing

LENOVO PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF

ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED

TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT,

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors.

Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change

Lenovo product specifications or warranties.

Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary.

Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.

Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk.

© Copyright Lenovo 2016

61

Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.

62

CN4093 10Gb Converged Scalable Switch Installation Guide

Trademarks

Lenovo, the Lenovo logo, Flex System, System x, NeXtScale System, and

X-Architecture are trademarks of Lenovo in the United States, other countries, or both.

Intel and Intel Xeon are trademarks of Intel Corporation in the United States, other countries, or both.

Internet Explorer, Microsoft, and Windows are trademarks of the Microsoft group of companies.

Linux is a registered trademark of Linus Torvalds.

Other company, product, or service names may be trademarks or service marks of others.

© Copyright Lenovo 2016 Appendix B: Notices

63

Important Notes

Processor speed indicates the internal clock speed of the microprocessor; other factors also affect application performance.

CD or DVD drive speed is the variable read rate. Actual speeds vary and are often less than the possible maximum.

When referring to processor storage, real and virtual storage, or channel volume,

KB stands for 1 024 bytes, MB stands for 1 048 576 bytes, and GB stands for 1 073

741 824 bytes.

When referring to hard disk drive capacity or communications volume, MB stands for 1 000 000 bytes, and GB stands for 1 000 000 000 bytes. Total user-accessible capacity can vary depending on operating environments.

Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and population of all hard-disk-drive bays with the largest currently supported drives that are available from Lenovo.

Maximum memory might require replacement of the standard memory with an optional memory module.

Each solid-state memory cell has an intrinsic, finite number of write cycles that the cell can incur. Therefore, a solid-state device has a maximum number of write cycles that it can be subjected to, expressed as total bytes written (TBW). A device that has exceeded this limit might fail to respond to system-generated commands or might be incapable of being written to. Lenovo is not responsible for replacement of a device that has exceeded its maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the device.

Lenovo makes no representations or warranties with respect to non-Lenovo products. Support (if any) for the non-Lenovo products is provided by the third party, not Lenovo.

Some software might differ from its retail version (if available) and might not include user manuals or all program functionality.

64

CN4093 10Gb Converged Scalable Switch Installation Guide

Recycling information

Lenovo encourages owners of information technology (IT) equipment to responsibly recycle their equipment when it is no longer needed. Lenovo offers a variety of programs and services to assist equipment owners in recycling their IT products. For information on recycling Lenovo products, go to: http://www.lenovo.com/recycling

© Copyright Lenovo 2016 Appendix B: Notices

65

Particulate Contamination

Attention: Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the device that is described in this document.

Risks that are posed by the presence of excessive particulate levels or concentrations of harmful gases include damage that might cause the device to malfunction or cease functioning altogether. This specification sets forth limits for particulates and gases that are intended to avoid such damage. The limits must not be viewed or used as definitive limits, because numerous other factors, such as temperature or moisture content of the air, can influence the impact of particulates or environmental corrosives and gaseous contaminant transfer. In the absence of specific limits that are set forth in this document, you must implement practices that maintain particulate and gas levels that are consistent with the protection of human health and safety. If Lenovo determines that the levels of particulates or gases in your environment have caused damage to the device, Lenovo may condition provision of repair or replacement of devices or parts on implementation of appropriate remedial measures to mitigate such environmental contamination.

Implementation of such remedial measures is a customer responsibility.

Contaminant Limits

Particulate

Gaseous

The room air must be continuously filtered with 40% atmospheric dust spot efficiency (MERV 9) according to ASHRAE Standard 52.2

1

.

Air that enters a data center must be filtered to 99.97% efficiency or greater, using high-efficiency particulate air (HEPA) filters that meet

MIL-STD-282.

The deliquescent relative humidity of the particulate contamination must be more than 60%

2

.

The room must be free of conductive contamination such as zinc whiskers.

Copper: Class G1 as per ANSI/ISA 71.04-1985

3

Silver: Corrosion rate of less than 300 Å in 30 days

1

ASHRAE 52.2-2008 - Method of Testing General Ventilation Air-Cleaning Devices for

Removal Efficiency by Particle Size. Atlanta: American Society of Heating,

Refrigerating and Air-Conditioning Engineers, Inc.

2

The deliquescent relative humidity of particulate contamination is the relative humidity at which the dust absorbs enough water to become wet and promote ionic conduction.

3

ANSI/ISA-71.04-1985. Environmental conditions for process measurement and

control systems: Airborne contaminants. Instrument Society of America, Research

Triangle Park, North Carolina, U.S.A.

66

CN4093 10Gb Converged Scalable Switch Installation Guide

Telecommunication Regulatory Statement

This product may not be certified in your country for connection by any means whatsoever to interfaces of public telecommunications networks.

Further certification may be required by law prior to making any such connection.

Contact a Lenovo representative or reseller for any questions.

© Copyright Lenovo 2016 Appendix B: Notices

67

Electronic Emission Notices

When you attach a monitor to the equipment, you must use the designated monitor cable and any interference suppression devices that are supplied with the monitor.

Federal Communications Commission (FCC) Statement

Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a

Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Lenovo is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user's authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and

(2) this device must accept any interference received, including interference that may cause undesired operation.

Industry Canada Class A Emission Compliance Statement

This Class A digital apparatus complies with Canadian ICES-003.

Avis de Conformité à la Réglementation d'Industrie Canada

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du

Canada.

Australia and New Zealand Class A Statement

Attention: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

68

CN4093 10Gb Converged Scalable Switch Installation Guide

European Union - Compliance to the Electromagnetic Compatibility

Directive

This product is in conformity with the protection requirements of EU Council

Directive 2004/108/EC (until April 19, 2016) and EU Council Directive 2014/30/EU

(from April 20, 2016) on the approximation of the laws of the Member States relating to electromagnetic compatibility. Lenovo cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the installation of option cards from other manufacturers.

This product has been tested and found to comply with the limits for Class A equipment according to European Standards harmonized in the Directives in compliance. The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment.

Lenovo, Einsteinova 21, 851 01 Bratislava, Slovakia

Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Germany Class A Statement

Deutschsprachiger EU Hinweis:

Hinweis für Geräte der Klasse A EU-Richtlinie zur Elektromagnetischen

Verträglichkeit

Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie 2014/30/EU

(früher 2004/108/EC) zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den EU-Mitgliedsstaaten und hält die

Grenzwerte der Klasse A der Norm gemäß Richtlinie.

Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der Lenovo empfohlene Kabel angeschlossen werden. Lenovo übernimmt keine

Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung der Lenovo verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne Empfehlung der Lenovo gesteckt/eingebaut werden.

Deutschland:

Einhaltung des Gesetzes über die elektromagnetische Verträglichkeit von

Betriebsmittein

Dieses Produkt entspricht dem „Gesetz über die elektromagnetische

Verträglichkeit von Betriebsmitteln“ EMVG (früher „Gesetz über die elektromagnetische Verträglichkeit von Geräten“). Dies ist die Umsetzung der

EU-Richtlinie 2014/30/EU (früher 2004/108/EC) in der Bundesrepublik

Deutschland.

© Copyright Lenovo 2016 Appendix B: Notices

69

Zulassungsbescheinigung laut dem Deutschen Gesetz über die elektromagnetische Verträglichkeit von Betriebsmitteln, EMVG vom 20. Juli

2007 (früher Gesetz über die elektromagnetische Verträglichkeit von Geräten), bzw. der EMV EU Richtlinie 2014/30/EU (früher 2004/108/EC ), für Geräte der

Klasse A.

Dieses Gerät ist berechtigt, in Übereinstimmung mit dem Deutschen EMVG das

EG-Konformitätszeichen - CE - zu führen. Verantwortlich für die

Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo (Deutschland)

GmbH, Meitnerstr. 9, D-70563 Stuttgart.

Informationen in Hinsicht EMVG Paragraf 4 Abs. (1) 4:

Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse

A.

Nach der EN 55022: „Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen; in diesem Fall kann vom

Betreiber verlangt werden, angemessene Maßnahmen durchzuführen und dafür aufzukommen.“

Nach dem EMVG: „Geräte dürfen an Orten, für die sie nicht ausreichend entstört sind, nur mit besonderer Genehmigung des Bundesministers für Post und

Telekommunikation oder des Bundesamtes für Post und Telekommunikation betrieben werden. Die Genehmigung wird erteilt, wenn keine elektromagnetischen

Störungen zu erwarten sind.“ (Auszug aus dem EMVG, Paragraph 3, Abs. 4).

Dieses Genehmigungsverfahrenist nach Paragraph 9 EMVG in Verbindung mit der entsprechenden Kostenverordnung (Amtsblatt 14/93) kostenpflichtig.

Anmerkung: Um die Einhaltung des EMVG sicherzustellen sind die Geräte, wie in den Handbüchern angegeben, zu installieren und zu betreiben.

VCCI Class A Statement

This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI). If this equipment is used in a domestic environment, radio interference may occur, in which case the user may be required to take corrective actions.

70

CN4093 10Gb Converged Scalable Switch Installation Guide

Japan Electronics and Information Technology Industries Association

(JEITA) Statement

Japanese Electronics and Information Technology Industries Association (JEITA)

Confirmed Harmonics Guideline (products less than or equal to 20 A per phase).

Japan Electronics and Information Technology Industries Association (JEITA)

Confirmed Harmonics Guidelines with Modifications (products greater than 20 A per phase).

Korea Communications Commission (KCC) Statement

This is electromagnetic wave compatibility equipment for business (Type A).

Sellers and users need to pay attention to it. This is for any areas other than home.

Russia Electromagnetic Interference (EMI) Class A Statement

People’s Republic of China Class A Electronic Emission Statement

Taiwan Class A Compliance Statement

© Copyright Lenovo 2016 Appendix B: Notices

71

72

CN4093 10Gb Converged Scalable Switch Installation Guide

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents