ACCESSOrIES AIR CONDITIONING
LG HVAC SOLUTION
Accessories
AIR CONDITIONING
LG Electronics
AE Company, Commercial Conditioning
Two IFC, 10 Gukjegeumyung-ro, Yeongdeungpo-gu, Seoul 150-945
www.lg.com www.lgeaircon.com
Copyright © 2014 LG Electronics. All rights reserved.
Distributed by
Greenovation
Greenovation represents some of LG’s core values including reducing greenhouse gas emissions, promoting sustainable growth
with suppliers and developing new green businesses.
Green Vision
LG’s green vision is to provide values that enhance the quality of life for its consumers and create a healthier and cleaner
environment.
Green Goals
LG is committed to creating innovation values that contribute to environmental protection through Greenovation activities
Green Strategy
LG is working towards minimising its environmental impact through the entire production process to deal with various
environmental issues, including climate change. To achieve this, LG has established the following five green management
strategies:
• Respond pro-actively to climate change
• Strengthen ‘Green’ energy business
• Enhance ‘Green’ product development
• Promote green and sustainable growth
• Facilitate resource recycling
Green Management
The Green Technology Committee makes decisions concerning LG’s green management strategy. It consists of CTO
(Chief Technical Officer) as the head and executive officers, including a research director. The Green Technology
Committee aims to create operational initiative for development of green technologies and products.
Green Business
• Solar Business • Lighting Solution Business • HVAC Business • Water Treatment Business • Smart Grids Business
We’re in the business of creating comfort for any season in the year through Heating, Ventilation and Air-Conditioning
solutions. LG provides a total HVAC system with optimised heating, ventilation and air conditioning solutions carefully
adapted to the unique conditions of each site during the building’s construction or renovation. The company is also engaging
in the development of green buildings through its line of products using renewable energy. For example, our MULTI V Water
uses geothermal energy, which is known as a constant source of heating and cooling that maintains a temperature of
15±5C regardless of the surface temperature.
By the year
20
%
Primary Energy
Consumption
20
%
Greenhouse Gas
Emissions
20
%
Sharing of
Renewable Energy
2020
LG HVAC SOLUTION
INDEX
Air conditioner Control System
08 Remote Controller
14 Central Controller
22 Gateway
30 Electronic Accessories
Vitalizing
every
environment
Mechanical Accessories
52 Mechanical Accessories
LG IMPROVES QUALITY OF LIFE
In an affordable, eco-friendly way. Over the years, LG has strived to meet
the demand for high quality air conditioning solutions with greater energy efficiency,
that can reduce energy costs and also help protect the environment.
Greater energy savings can be achieved over the lifetime of the product that can offer
cost savings to your home and business.
Piping Accessories
66 Piping Accessories
ACCESSORIES
AIR CONDITIONER CONTROL SYSTEM LINE UP
Remote Controller
Central Controller
Wired Remote
Controller
Simple
standard
Wireless Remote
Controller
Deluxe
Simple Central
Controller
AC
Smart Premium
Central Controller
ACP
(Advanced Control Platform)
&
AC Manager Plus
AHU Kit
Gateway
Building
Network Unit
(Air Handling Unit)
PI 485
&
DO Kit
Electronic Accessories
• PDI (Power Distribution Indicator)
Premium
(Digital Output Kit)
• Dry Contact
Communication kit
Premium
PRCKA0
PRDCA0
• I/O Module (Input / Output Module)
• Variable Water Flow Control kit
• Independent Power Module
• Remote Temperature Sensor
PQRCVCL0Q
PQRCVSL0
(Black/Simple)
PQRCUDS0
(White)
PREMTA000
PQWRHQ0FDB(H/P)
AC Ez
AC Smart Premium
PQCSZ250S0
PQCSW421E0A
ACP (Advanced Control Platform)
Standard
ACP LonWorks Gateway
PLNWKB000
PQCPC22NO
• Cool/Heat Selector
PI 485
PMNFP14A1
PHNFP14A0
PSNFP14A0
ACP (Advanced Control Platform)
Premium
EEV kit
(Electronic Expansion Valve kit)
PRLK048A0
PRLK096A0
• Group Control Wire
• Zone Controller
PQCPC22AO
AC Manager Plus
PQRCVCL0QW
(White/Simple)
PQRCVSL0QW
PQRCUDSOB
(Blue)
PQCSSA21EO
ACP BACnet/Modbus Gateway
DO Kit (Digital Output Kit)
PQNFB17C0
PQNFP00T0
Control kit
PRCKD21E
PRCKD41E
PQRCHCA0Q
(Black/Simple for Hotel)
PQRCUDSOS
(Silver)
KNX Gateway
Expnsion kit
PATX13A0E
PATX20A0E
PATX25A0E
PATX35A0E
PATX50A0E
PQRCHCA0QW
(White/Simple for Hotel)
6
7
REMOTE CONTROLLER
SIMPLE WIRED
REMOTE CONTROLLER
Simple Wired
Remote Controller
Standard Wired
Remote Controller
> Page 9
> Page 10
Deluxe Wired
Remote Controller
Premium Wired
Remote Controller
Air conditioner Control System
A simple way to control office or hotel systems in a compact design
Simple
PQRCVCL0QW (White)
PQRCVCL0Q (Black)
> Page 11
> Page 12
Remote Controller
Simple for Hotel
PQRCHCA0QW (White)
PQRCHCA0Q (Black)
Wireless
Remote Controller
> Page 13
Features
Model name
Operating mode
Room temperature
Child lock
Mode change
Backlight
Remote Controller Line Up
PQRCVCL0Q / PQRCVCLOQW
PQRCHCA0Q / PQRCHCA0QW
On/Off / Fan speed / Mode / Temperature
On/Off / Fan speed / Mode / Temperature
O
O
O
O
Cooling / Heating / Fan / Dehumidify / Auto
Only changeable by central controller
O
O
* Refer to each model block for applicable models.
Model name
On/Off
8
PQRCVCL0Q
PQRCVCL0QW
PQRCHCA0Q
PQRCHCA0QW
PQRCVSL0
PQRCVSL0QW
PQRCUDS0 (B,S)
PREMTA000
PQWRHQ0FDB
(H/P)
O
O
O
O
O
O
Fan speed
O
O
O
O
O
O
Temperature setting
O
O
O
O
O
O
Mode change
O
-
O
O
O
O
O
O
O
O
O
Auto swing
O
Vane control (Louver direction)
O
-
O
O
O
O
E.S.P (External Static Pressure) function
O
O
O
O
O
-
Reservation
-
-
O
O
O
O
Time function
-
-
O
O
O
O
Electric failure compensation
-
-
O
-
50 hours
-
Child lock
O
O
O
O
O
-
9
DELUXE WIRED
REMOTE CONTROLLER
Providing easy control of one or a group of indoor units to various applications
Touch screen with a premium design for high end interior designs
PQRCUDS0
PQRCUDS0B
PQRCUDS0S
PQRCVSL0
PQRCVSL0QW
PQRCVSL0QW
(White)
PQRCUDS0S
(Silver)
PQRCVSL0
(Black)
Features
Operating mode
Maximum number of indoor units
On/Off LED
Room temperature
Fan / Plasma / Swirl / Heater
Vane control (Louver direction) / Auto swing / Fan auto
E.S.P (External Static Pressure) function
Reservation
Time function
Child lock
Electric failure compensation
Wireless remocon receiver
Main/Sub setting of indoor units (For override function)
2 Controllers to 1 indoor unit
Group and central control at the same time
Ventilation mode setting
Rapid ventilation
Power saving ventilation
Dimensions (W X H X D, mm)
Backlight Unit
PQRCUDS0B
(Blue)
Remote Controller
PQRCUDS0
(White)
Model name
Air conditioner Control System
STANDARD WIRED
REMOTE CONTROLLER
Features
PQRCVSL0 / PQRCVSL0QW
On/Off / Fan speed / Mode / Temperature
16
O
O
O
O
O
On/Off / Weekly / Simple / Sleep / Holiday
O
O
Model name
Operating mode
Touch screen / LCD back_light
Room temperature
Fan / Plasma / Swirl / Heater
Vane control (Louver direction) / Auto swing
E.S.P (External Static Pressure) function
Reservation
Time function
Child lock
PQRCUDS0 / PQRCUDS0B / PQRCUDS0S
On/Off / Fan speed / Mode / Temperature
O
O
O
O
O
Weekly / Simple
O
O
* Refer to each model block for applicable models.
Max 3 hours
O
Applicable for MULTI V II, III and IV series.
Applicable for MULTI V II, III and IV series.
Applicable for MULTI V II, III and IV series.
Applicable for ERV II series.
Applicable for ERV II series.
Applicable for ERV II series.
120 x 121 x 16
O
* Terminal Block included. (Applied to models produced since ’10 Nov.)
* Refer to each model block for applicable models.
10
11
WIRELESS
REMOTE CONTROLLER
5inch full touch screen with a premium design
Wireless control to operate air conditioners more conveniently
Air conditioner Control System
Premium WIRED
REMOTE CONTROLLER
PQWRHQ0FDB (H/P)
PREMTA000
Remote Controller
* Available from July
Features
1) Self administration function for Energy saving
- Air-conditioning saving mode / Continuous operation time limit / Electricity consumption monitoring.
- Weekly / Monthly / Yearly Trend / Target setting alarm.
- Temperature scope locking (cooling / heating)
2) User friendly design
- Full touch type / Intuitive UI&GUI design / Display Configuration.
3) Enhanced schedule function
- Yearly schedule function / Schedule pattern
Features
4) Various localized function mode
- 2 Set point / Setback / Override / 8 Zone Control / Summer Time.
Model name
Operating mode
Maximum number of indoor units
On/Off LED
Room temperature
Fan / Plasma / Swirl / Heater
Vane control (Louver direction) / Auto swing / Fan auto
E.S.P (External Static Pressure) function
Reservation
Time function
Child lock
Electric failure compensation
Wireless remocon receiver
Main/Sub setting of indoor units (For override function)
2 Controllers to 1 indoor unit
Group and central control at the same time
Ventilation mode setting
Rapid ventilation
Power saving ventilation
Dimensions (W X H X D, mm)
Display
Touch type
PREMTA000
On/Off / Fan speed / Mode / Temperature
16
O
O
O
O
O
Model name
Operating mode
Room temperature checking
Chaos swing / Jet cool
On/Off timer
Sleep mode auto
Main / Sub setting of indoor units (For override function)
PQWRHQ0FDB (H/P)
On/Off / Fan speed / Mode / Temperature
O
O
O
O
Applicable for MULTI V II, III and IV series.
* Refer to each model block for applicable models.
Timer (simple/sleep) / Daily(On/Off) / Weekdays / Yearly / Holiday
O
O All / Individual (On/Off, Mode, Temperature)
50 hours
O (Only for ceiling duct type indoor unit)
Applicable for MULTI V II, III and IV series.
* Applicable for after MULTI V IV Series indoor unit.
Applicable for MULTI V II, III and IV series.
Applicable Models
Applicable for ERV II series.
Applicable for ERV II series.
Model name
Applicable for ERV II series.
CST, SRAC, CVT, Duct*, Floor Standing
137 x 121 x 16.5
5" TFT color LCD (480 x 272)
RESISTIVE Touch pannel
PQWRHQ0FDB (H/P)
O
* Combination with other remote controllers for various indoor units.
*All Duct products can be controlled through wireless remote controller when wired remote controller is installed.
* Must check compatibility between indoor unit and remote controller before installation with
2 controllers to 1 indoor unit function (see user&installer manual for this product).
12
13
CENTRAL CONTROLLER
AC Ez
AC Ez
AC Smart Premium
> Page 15
> Page 16
PQCSZ250S0
ACP
(Advanced Control Platform)
Standard / Premium
> Page 18
AC Manager Plus
Name and description of the system
Air conditioner Control System
In addition to On/Off control, more functions such as operation mode, fan
speed, and scheduling can be run and monitored
LCD Display
Central Controller
Control mode select button
> Page 20
Total On/Off control
Detailed function
control part
Lock control
Individual Indoor On/Off control and LED Display
Features
Model name
Maximum number of indoor units
Individual control
Lock function
Mode change
Schedule
Ventilation control
Display (All Indoor status indication)
Dimensions (W X H X D, mm)
Power
Central Controller Line Up
PQCSZ50S0
32
On/Off / Operation Mode / Fan Speed / Temperature
Central
Cooling / Heating / Fan / Dehumidification / Auto
8 event schedule/day
On/Off / Ventilation Mode / Fan Speed
Operation, Set temp, Room Temp, Schedule
190x120x17
DC 12V
Model name
PQCSZ250S0
On/Off
Maximum number of indoor units
Mode change
Control of each room
Total lock
Error check
Fan speed / Temperature control
Schedule
Ventilation control
PDI Monitoring
Web access
Set temperature range restriction
Auto changeover
Temperature limit control
History
Interlocking function
Multi languages
Visual Navigation
14
PQCSW421E0A
PQCPC22N0
PQCPC22A0
PQCSSA21E0
O
O
O
O
32
128
256
8,192
O
O
O
O
O
O
O
O
O
O
O
O
LED/LCD display
Self- diagnosis
Self- diagnosis
Self- diagnosis
O
O
O
O
Weeky
Weeky / Yearly
Weeky / Yearly
Weeky / Yearly
O
-
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Combination
PI 485
PHNFP14A0
PQCSZ250S0
MULTI V II
MULTI V III
MULTI V IV
MULTI V WATER II
MULTI V WATER IV
PMNF14A12)
MULTI V SPACE II
MULTI V SPACE III
MULTI V MINI 1)
ERV
MULTI,
Single CAC
1) ARUN40GS2A / ARUV40GS2A Only needs PI485
2) Max 64 indoor units
15
AC SMART PREMIUM
PQCSW421E0A
Improved web functions / Intuitive GUI design
Visual navigation
Energy report
AHU (Air Handling Unit) control
With its user-friendly Web GUI, A
C Smart Premium shows
current status of air conditioners and summary of schedule.
Air conditioner Control System
New AC Smart Premium provides a user-friendly GUI with 10.2 inch screen
Floor plan (jpg format) can be edited according to the air conditioners
location and shows the status.
Central Controller
• Visual navigation
• User friendly GUI (Graphic User Interface)
• Screen size up (10.2inch) and resolution (1024*600)
• 2 D/I and 2 D/O ports for interlocking function
• Energy bill calculation function
• 2 Point setback
• 2 Point auto changeover
• E-mail of statistics
Control / Monitoring
controls and monitors the operation status of the air conditioner /
ERV / Hydro kit / DO (Digital Output) Kit devices.
Schedule
Operates the air conditioners, ERV, AHU (Air Handling Unit), AWHP,
Hydro Kit and DO (Digital Output) Kit connected to AC Smart
Premium according to the schedule.
Automation control
- Peak Control : user can set the peak operation rate, ACSmart
premium manages the air conditioners not to exceed their power
consumption more than set rate.
- Interlocking : User can set input condition and output condition,
so that , if input condition is true, output condition will be activated.
(ex. Input condition : UNIT_00 is ON, output condition : UNIT_01 is ON. )
Time limit Control : ACSmart premium will allow the air
conditioners only specified amount time.
16
Home Screen
Statistics
Displays power consumption or usage of the air conditioners.
AC Smart premium shows statistical data about indoor units
(Operation hours / Power consumption)
AC Smart Premium provides various control functions to users.
Combination
It is possible to control the unit (IDU, ERV, on/off, AWHP, Hydro Kit, ERV DX, AHU) and register the units.
Report
Displays the history of any errors that have occurred in the
airconditioners.
PI 485
Device setting
Registers, modifies or Device setting air conditioners, ERV, AHU
(Air Handling Unit), AWHP, Hydro Kit and DO (Digital Output) Kit
connected to AC Smart Premium.
PI 485
PHNFP14A0
MULTI V II
MULTI V III
MULTI V IV
MULTI V WATER II
MULTI V WATER IV
MULTI V SPACE II
MULTI V SPACE III
MULTI V MINI *
PMNF14A1
AWHP
AHU
Configure
General contents, user accounts, network, E-mail account, set up
TMS contents etc.
ERV
MULTI,
Single CAC
* ARUN40GS2A/ARUV40GS2A Only needs PI485
17
(Advanced Control Platform)
Air conditioner Control System
(Standard / Premium) With its Linux bases web server, users can control up to
256 unit including indoor unit, ERV, Hydro kit, AHU (only Premium model) Also
it has schedule / peak / power consumption report function
Combination
Standard
PQCPC22N0
Premium
Product Name
External I/O Port No.
ACP Standard
D/I 2, D/O 2
ACP Premium
D/I 10, D/O 4
Interfaceable Products
Air conditioner/
ERV/ ERV DX /
AHWP / Hydro kit
Air conditioner/
ERV/ ERV DX/
AWHP/ Hydro Kit / AHU
PI 485
PQCPC22N0 (ACP Standard)
PQCPC22A0 (ACP Premium)
PI 485
PHNFP14A0
AC Ez
MULTI V II
MULTI V III
MULTI V IV
MULTI V WATER II
MULTI V WATER IV
MULTI V SPACE II
MULTI V SPACE III
MULTI V MINI 1)
AWHP
AHU
PMNF14A1 3)
(Only PQCPC22A0) 2)
or
Features
Internet
Model name
PQCPC22N0 / PQCPC22A0
Maximum number of indoor units
Control / Monitoring
Schedule management
Lock function
Temperature range restriction
Temperature limit function
Auto changeover function
History function
Peak control
PDI monitoring
Auto address searching function
Statistics function
Peak Priority funtion
ERV, ERV DX Control
ERV
AC Smart Premium
256
O
O
MULTI,
Single CAC
1) ARUN40GS2A/ARUV40GS2A Only needs PI485
2) ACP (Advanced Control Platform) Premium
3) Max 64 indoor units
Mode, Temperature, Fan
18oC ~ 30oC
O
O
Error history
O
Need of PDI
O
O
O
O
Remote
Access
New Function
Upgrade
(Advanced Control Platform)
18
Control /
Monitor
Stand Alone
Operation
Power
Proportional
Peak Power
Control
Various Controller
Combination
Schedule
19
Central Controller
PQCPC22A0
PLUS
Air conditioner Control System
Provides efficient control and monitoring system for up to 8,192 indoor units by
connecting 32 ACPs
Combination
PQCSSA21E0
MULTI V II
MULTI V III
MULTI V IV
HUB
MULTI V WATER II
MULTI V WATER IV
PI 485
PI 485
PHNFP14A0
PMNF14A12)
MULTI V SPACE II
MULTI V SPACE III
MULTI V MINI 1)
MULTI,
Single CAC
ERV
Features
1) ARUN40GS2A/ARUV40GS2A Only needs PI485
2) Max 64 indoor units
Internet
Model name
PQCSSA21E0
Maximum number of indoor units
Control / Monitoring
Schedule management
Lock function
Temperature range restriction
Temperature limit function
Auto changeover function
History function
Peak control
PDI monitoring
Printing function
Statistics function
Time limit function
ERV, ERV DX Control
Peak Priority function
Interlocking function
AHU Control function
Hydro Kit, AWHP Control
8,192 (32 ACP)
Max. 32 ACP
O
O
Mode/Temperature/Fan speed/Total
MULTI V II
MULTI V III
MULTI V IV
O
O
O
MULTI V WATER II
MULTI V WATER IV
PI 485
PI 485
PHNFP14A0
PMNF14A12)
MULTI V SPACE II
MULTI V SPACE III
MULTI V MINI 1)
ERV
Monitoring & Error history
MULTI,
Single CAC
1) ARUN40GS2A/ARUV40GS2A Only needs PI485
2) Max 64 indoor units
O
Need of PDI
O
O
O
O
O
O
O
O
Plus Application
Multi Area Management
The product specially designed for multi area management.
-Central control & monitor Max. 8,192 indoor units & Max. 32 ACP
Visual Navigation
Max. 8,192 Indoor
&
20
PLUS
Control /
Monitor
Fire Alarm
Stand Alone
Operation
Power
Proportional
Peak Power
Control
Schedule
Various Controller
Combination
Korean reference site.
ACP
AC Manager Plus
21
Central Controller
AC Manager Plus
PQCSSA21E0
GATEWAY
> Page 24
> Page 25
PI 485
DO Kit
(Digital Output Kit)
> Page 26
> Page 27
Gateway
ACP BACnet/Modbus
Gateway
Air conditioner Control System
ACP LonWorks Gateway
KNX Gateway
> Page 28
22
23
ACP LonWorks Gateway
ACP BACnet Gateway
Interface between BMS (Building Management System) and LG air conditioner
• BTL certified : Operation system based on BACnet Service.
PLNWKB000
PQNFB17C0
Interface between BMS (Building Management System)
and LG air conditioners.
Improved BMS (Building Management System) connection.
- LonMark certified : Operation system based on LNS(
Air conditioner Control System
Interface between BMS (Building Management System) and LG air conditioner
- With its Linux bases web server, users can control up to 256 unit including indoor unit,
ERV, Hydro kit, AHU . Also it has schedule/peak/power consumption report function.
Network Service)
Control various types of equipment from the customer’s own PC.
Features
Features
• Connect to use
• Process ability
protocol and LG air conditioner protocol.
- EHP Type : 64 unit (indoors, ERV and AWHP)
- AHU (Air Handling Unit) Type : 16 unit (AHU)
• Self installation verification function using internet (Web server included)
- Setting gateway
- Diagnosis of communication status on LG Air-conditioner network
• Connection to remote total management system (LG system)
• It offers ACP (Advanced Control Platform) function (Central Controller)
which allows the customer to efficiently control various types of
equipment from the customer’s own PC.
Controlling
Monitoring items
On/Off command
Operation mode setting
Fan speed setting
Lock setting
Air flow setting
Set temp. setting
User mode setting (for only ERV)
Upper limit temp. setting
Low limit temp. setting
Mode lock setting
AC operation mode setting (ERV DX only)
On/Off status report
Operation mode status report
Fan speed status report
Lock status report
Air flow status report
Set temperature status report
Current Space temperature status report
Error status report
User mode status report (for only ERV)
Accumulator power distribution status report
Upper limit temperature status report
Low limit temperature status report
Mode lock status report
AC operation mode status report (ERV DX only)
AC On/Off command (ERV DX only)
AC On/Off status report (ERV DX only)
* For more information, see 18 page
Combination
Network
Gateway
- With its Linux based web server, users can control functions such as temperature setting,
schedule, peak, power control, etc.
• Through embedded web control function in BACnet ,one can access
the air conditioner and external devices through
BMS (Building Management System)
• ACP (Advanced Control Platform) New platform & Smart base GUI driven.
• Max 256 unit ( Indoor / ERV / ERV DX / Hydro kit / AWHP, AHU). Max number of AHU is 16.
• It is compatible with AC Ez and AC Smart Premium.
• External devices such as fire alarm, motion detector can be
connected to gateway and their function can be interlinked with air conditioner operation using BACnet.
• Compatible with MULTI V, Multi, Single system & AWHP.
• Supporting a 1°F control.
• BTL certification (B-ASC)
• It offers ACP (Advanced Control Platform) function (Central Controller)
which allows the customer to efficiently control various types of
equipment from the customer’s own PC.
Controlling
Monitoring items
On/Off command
Operation mode setting
Fan speed setting
Lock setting
Air flow setting
Set temp. setting
User mode setting (for only ERV)
Upper limit temp. setting
Low limit temp. setting
Mode lock setting
AC operation mode setting (ERV DX only)
On/Off status report
Operation mode status report
Fan speed status report
Lock status report
Air flow status report
Set temperature status report
Current Space temperature status report
Error status report
User mode status report (for only ERV)
Accumulator power distribution status report
Upper limit temperature status report
Low limit temperature status report
Mode lock status report
AC operation mode status report (ERV DX only)
AC On/Off command (ERV DX only)
AC On/Off status report (ERV DX only)
* For more information, see 18 page
Combination
LON comm. line
Network
Lighting control
BMS system
Remote checking
Indoor unit : Max. 64 units (Air-conditioner & ventilation)
Indoor address : 00 - FF
BACnet comm. line
Utility control
Other LON devices
Lighting control
Remote checking
Indoor unit : Max. 256 units (Air-conditioner & ventilation)
Indoor address : 00 ~ FF
PLNWKB000
AC Ez
or
MULTI V II
MULTI V III
MULTI V IV
PI 485
PI 485
PHNFP14A0
PMNF14A1 2)
MULTI V WATER II MULTI V SPACE II
MULTI V WATER IV MULTI V SPACE III
MULTI V MINI 1)
AWHP
AHU
AC Ez
PMNF14A1 2)
PHNFP14A0
MULTI V II
MULTI V III
MULTI V IV
MULTI V WATER II MULTI V SPACE II
MULTI V WATER IV MULTI V SPACE III
MULTI V MINI 1)
AWHP
AHU
Internet
AC Smart Premium
ERV
MULTI,
Single CAC
1) ARUN40GS2A/ARUV40GS2A Only needs PI485
2) Max 64 indoor units
24
PI 485
PI 485
PQNFB17C0
or
Internet
Utility control
Other BACnet devices
AC Smart Premium
ERV
MULTI,
Single CAC
1) ARUN40GS2A/ARUV40GS2A Only needs PI485
2) Max 64 indoor units
25
DO KIT (Digital Output Kit)
PI 485 converts the air conditioner's protocol to the RS485 protocol for the
central controller
Connected between AC Manager Plus (or ACP, AC Smart) and external devices,
which can switch On/Off devices such as light, pump, motor, etc
PQNFP00T0
Features
Features
• Model name : PMNFP14A1
• Power : Single phase AC 220V 50/60Hz
• 1 for each outdoor unit (max 64 indoor units)
• When the product input is less or equal to 25A
(The device is controlled by turning On/Off the power supply line of the product.)
- MULTI V MINI (ARUN40GS2A/ARUV40GS2A Only needs PI485)
- SCAC
- MULTI
- AWHP
• Model name : PHNFP14A0
• Power : Connected with the indoor units
• 1 for each unit
Gateway
PMNFP14A1
PHNFP14A0
PSNFP14A0
1. Pull out the power or shut down the breaker.
2. Connect the power line from the breaker to the additional relay cable.
3. Connect the device power line to the additional relay cable.
4. Finish the connected area with the insulating tape.
• When the product input is greater or equal to 25A
(The device is controlled by turning On/Off the indoor/outdoor communication line.)
- ERV
1. Pull out the power or shut down the breaker.
2. Cut the communication line.
3. Connect the cut communication line to the additional relay cable.
4. Finish the connected area with the insulating tape.
• Model name : PSNFP14A0
• Power : Connected with the indoor units
• 1 for each indoor unit
- Non-inverter products
* Provided with a case to be installed on the exterior.
•When the product input is greater than or equal to 25A
(The device is controlled by turning On/Off the power supply line of the product thrue a field-supplied relay)
* MULTI V II & III & IV series don’t need any other PI 485 because MULTI V II & III & IV series have PI 485 in its outdoor unit PCB.
26
Air conditioner Control System
PI 485
1. Pull out the power or shut down the breaker.
2. Connect the power line from the breaker to the additional relay cable.
3. Connect the field-supply relay power line to the additional relay cable.
4. Connect the device power line to the field-supply relay.
5. Finish the connected area with the insulating tape.
27
KNX GATEWAY
Specially designed to allow monitoring and bidirectional control of all the
parameters and functionality of LG air conditioners from KNX installations
LG-AC-KNX-4
LG-AC-KNX-8
LG-AC-KNX-16
LG-AC-KNX-64
Air conditioner Control System
* This product is provided by INTESIS. For more information, please contact INTESIS directly
Main features
• Easy installation, direct connection to all outdoor units (communication interface PMNFP14A1, when needed) and
Heat recovering units (communication interface PHNFP14A0, when needed) throungh the RS485 Bus.
• Great integration flexibility. Using the supplied software LinkBoxEIB, a complete set of communication objects can be
accessed.
Gateway
Specifications
• Bidirectional: Monitoring and control.
• Robust and reliable hardware.
• Direct connection to KNX bus.
• Independent management of communications.
• Power supply: 9 to 24Vdc or 24Vac.
• Standard DIN-Rail 6 modules enclosure.
Combination
Models available
• Ref. LG-AC-KNX-4, with capacity of up to 4 indoor units.
• Ref. LG-AC-KNX-8, with capacity of up to 8 indoor units.
• Ref. LG-AC-KNX-16, with capacity of up to 16 indoor units.
• Ref. LG-AC-KNX-64, with capacity of up to 64 indoor units.
Configuration
Software
LinkBoxEIB
(Only needed for
configuration)
RS232
RS485
125mm2x2C
(shield)
Link BoxEIB configuration software for IntesisBox® KNX serious
Easy to use tool for the configuration of intesisBox, in a fast and effective way.
It offers the maximum integration possibilities with a minimal knowledge required on the system to be integrated.
IntesisBox
LG-AC-KNX-4
LG-AC-KNX-8
LG-AC-KNX-16
LG-AC-KNX-64
PI 485
PI 485
PHNFP14A0
PMNF14A1 2)
Other type of
IDU
MULTI V II
MULTI V III
MULTI V IV
MULTI V WATER II
MULTI V WATER IV
MULTI V SPACE II
MULTI V SPACE III
MULTI V MINI 1)
ERV
LinkBoxEIB
Configuration software
28
• Only needed during configuration.
• One single tool for the configuration of the whole range of IntesisBox
KNX series gateways.
• Supplied with IntesisBox with no additional cost.
• Configuration examples for all systems that can be integrated.
• Mapping table editable using excel, allowing a simple and fast association of KNX Group Addresses, exported from ETS, to
IntesisBox’s datapoints.
• Includes powerful and useful features for configuration, setup and
troubleshooting.
MULTI,
Single CAC
1) ARUN40GS2A/ARUV40GS2A Only needs PI485
2) Max 64 indoor units
29
Dry Contact
> Page 32
> Page 34
I/O Module
(Input / Output Module)
Variable Water Flow
Control Kit
> Page 39
> Page 40
Independent
Power Module
Remote Temperature
Sensor
> Page 42
> Page 43
Cool / Heat Selector
Group Control Wire
> Page 44
> Page 45
Zone Controller
AHU Kit
(Air Handling Unit)
> Page 46
> Page 48
30
Electronic Accessories
PDI Premium
(Power Distribution Indicator)
Air conditioner Control System
ACS
ELECTRONIC ACC.
31
PDI PREMIUM
(POWER DISTRIBUTION INDICATOR)
PQNUD1S40
Air conditioner Control System
For Multi Split, total power consumption is displayed
Error display
Shows accumulated power consumption of the system.
If no power detection signal is available
Features
Combination
• Connection to max 8 outdoors.
• Accumulated total power consumption of outdoor and indoor unit.
• Accumulated / Current Power Consumption of each indoor unit.
• Max 128 indoor units.
• RS-485 type wattmeter can be interlocked.
• Data back up.
Using Pulse Type Wattmeter : Independent operation of power indicator.
Power in
single phase
50Hz 220V
RS485
(LGAP)
Pulse Signal
Watt meter
Electronic Accessories
If communication with the product is not smooth
Watt meter
Power in
3 phase 4 win
50Hz 220V
Pulse Signal
Pulse Signal
Instantaneous power screen
Wattmeter number
Overall instantaneous power
of P(1) wattmeter
Instantaneous power of each
applicable indoor unit
Power cable of indoor unit
Shows the estimated value based on one minute power consumption.
Each indoor unit number
Total accumulated power consumption display
Shows accumulated power consumption of the system.
Wattmeter number
Overallaccumulated power
of P(1) wattmeter
Accumulated power of each
applicable indoor unit
or
ACP
AC Smart Premium
Each indoor unit number
32
33
DRY CONTACT
PQDSBNGCM1
Features
Features
Model name
Contact point
Power input
Voltage / Non voltage input
On/Off control
Lock / Unlock
Thermo off
Energy saving
Temperature setting
Error monitoring
Operation monitoring
PQDSA/ PQDSB
PQDSBC
1 Control point
2 Control points
AC 220V from outside power source
DC 5V&12V from indoor unit PCB
O
O
O
O
O
O
O
O
O
O
O
* Refer to each model block for applicable models.
* With case model : PQDSB , PQDSBC / Without case model : PQDSA
PQDSA , PQDSB
PQDSBC
Model name
Electronic Accessories
PQDSA
PQDSB
PQDSBC
Air conditioner Control System
Connection between an indoor unit and external devices to control various
functions
PQDSBNGCM1
Dimensions (W X H X D, mm)
Contact Point
Voltage / Non voltage input
On/Off control
Mode control
Fan Speed Setting
Thermo off
Error Monitoring
Operation monitoring
Rotary switch 1
Rotary switch 2
105 x 78 x 35
8 contact point
O
O
O (Cool, Heat, Fan)
O (Low, Middle, High)
O
O
O
Operating set temperature selection
Operating logic selection
PQDSBNGCM1
AC 220V(PQDSB)
AC 24V(PQDSB1)
INPUT
AC 220V(PQDSB)
AC 24V(PQDSB1)
To apply power source through PCB
To apply power source directly to external source
In case Non Voltage signal
In case Voltage signal
- For no power contact point signal input
- For power contact point signal input
- Indoor unit monitoring
Combination
Combination
Control Module
Dry contact
(Contact point linked
with outer part)
Key Switch
Lighting
Sensor
Fire Alarm
Timer
Motion
Detect Sensor
Door Check Sensor
System Structure
34
35
DRY CONTACT
Air conditioner Control System
Connection between an indoor unit and external devices to control various
functions
PQDSBCGCD0
Combination
1) Model name : PQDSBCGCD0
2) Specification
• Dimensions(mm) : 105x78x35
• Applied Model : MULTI V II, MULTI V III, MULTI V IV
• Function
RS485 Communication function.
Electronic Accessories
Features
* RCU : Room Control Unit.
<RS485 communication function>
Room
Control master
- Contact Point : 2 contact point (operation depends on the Control Mode_SW setting)
- Pl 485 Communication Mode Input : LGAP 485 Communication
- Voltage/Non Voltage Input
- Error Monitoring Output
- Operation Monitoring Output
RS485
(RCU)
Controller
3) Description
The product is especially designed for interface with other controllers using dry contact communication or RS485 communication.
<PQDSBC function>
Indoor unit
2 Contact
BUS A
BUS B
COMM
Input A
Input B
LG does not
Room Control supply this section
Unit
(Field supply)
Dry contact
Key
Fire Alarm
Field Supply
Error Display
Power
AC or DC
(Depends on Error display power type)
Operation Display
Power
AC or DC
(Depends on Operation display power type)
36
37
I/O Module (Input / Output Module)
Dry contact for demand control
UART to external device interface module for system air conditioner
PVDSMN000
Features
Features
1) Model name : PQDSBCDVM0
2) Specification
• Applied Model : MULTI V MINI, MULTI V SPACE II, MULTI V WATER II,
MULTI V WATER MINI
• Function
1) Model name : PVDSMN000
2) Specification
• Applied Model : MULTI V IV, MULTI V WATER IV
• Function
Error
display
- Demand control (3 contact signal)
- Demand control (Co-work with DDC)
- ODU fan low speed control (Night low noise operation)
- All Off
- Error Output (Display)
3) Description
The product is especially designed for demand control.
Electronic Accessories
PQDSBCDVM0
Air conditioner Control System
OUT DOOR UNIT DRY CONTACT
- Demand control
- Low speed control (Night low noise operation)
- Operation, error output
- Comp off, system off
Low noise
3) Description
By DDC
0~10V
or
By Dry
contact
I/O (Input / Output Module) Module is communication interface module for connection
between Multi V IV and external I/O (Input / Output Module) devices.
Demand control (input)
Combination
Combination
Simple Contact
Analogue Input
(0~10V)
Contact Signal
(0~10V input)
RS485
Max. 16
C/Box
Direct Digital
Controller
38
39
VARIABLE WATER FLOW
CONTROL KIT
PWFCKN000
Features
Features
1) Model name : PRVC0
2) Specification
• Applied Model : MULTI V WATER II
• Function
1) Model name : PWFCKN000
2) Specification
• Applied Model : MULTI V WATER IV
• Function
Electronic Accessories
PRVCO
Air conditioner Control System
Accessory developed for controlling the water flow
- Water pump valve control (0~10V)
- Minimum voltage setting available
- Operation, error output (display)
- Water pump valve control (0~10V)
- Minimum voltage setting available
- Operation, error output (display)
• Advantage
• Advantage
3) Description
- Water flow consumption reduction
- Pump electricity consumption reduction
- Including I/O module (Dry contact input, Analog input/output, Digital output)
: Using Dry contact and variable water flow control function simultaneously
The product is specially designed to control the water pump valve in MULTI V Water system.
3) Description
- Water flow consumption reduction
- Pump electricity consumption reduction
Cooling Tower
- Dry contact input and analog output for demand control
- Analog output for controlling third party devices
such as valve actuator and damper actuator (Max. 3 actuator)
- Digital output for connecting status display devices
Combination
Wiring Diagram
Wiring for Damper Actuator
BL : Blue
BR : Brown
RD : Red
Cooling Tower
Single Line
Water Flow Line
Flow
control
valve
Pump/Cooling
Tower Controller
AC 220V
BR
AC 220V
BL
Variable Water Flow Control Kit
BK : Black
WH : White
GR : Green
Damper Actuator
Flow meter
Main PCB
Flow
control
valve
Power Module
RD
Pressure
sensor
Transformer
RD
Flow meter
From Water Source
Inverter pump
• Flow control valve : Regulates the flow or pressure of a fluid, normally responding to signals generated by independent devices.
• Flow Meter : Measures mass flow rate of a fluid traveling through a tube. (The mass flow rate is the mass of the fluid traveling past a fixed point per unit time.)
• Pressure Sensor : Measures the pressure.
40
Terminal
Block
GR
I/O Module
BK
Signal
AC/DC 24V
WH
RD
41
REMOTE TEMPERATURE SENSOR
EEV full close function in case of power cut
Sensor for detecting the room temperature
PQRSTA0
Features
Features
1) Model name : PRIP0
2) Specification
• Applied Model : MULTI V Indoor
• Function
• It can help to detect the exact room temperature.
• Applied to ceiling cassette, ceiling concealed duct, AWHP and Hydro Kit.
- Supply Voltage : DV12V 5%
- Indoor EEV full close at power cut-off
Electronic Accessories
PRIP0
Air conditioner Control System
INDEPENDENT POWER MODULE
Parts Included
3) Description
The product is specially designed to close the Indoor EEV at power cut-off.
• Remote temperature sensor
• Extension cable (15m)
• Manual
Combination
Wiring Diagram
3 phase
400V
1. Wire to the control box in the indoor unit by removing the existing thermistor and connect the extension cable its place.
2. Cut the extension cable to the appropriate length and connect the screw terminal of the remote sensor.
Outdoor Unit
Independent Power Module (Option)
1 phase
220V
Switch BOX
4th
Connector
Main Switch
Extension cable
Power Plug
3rd
2nd A/C Switch
1st
Each room
Indoor unit
Independent Power Module (Option)
Switch BOX
Remote Temperature
Sensor
Main Switch
Power Plug
3rd
2nd A/C Switch
Screw terminal
connection
1st
Each room
42
43
GROUP CONTROL WIRE
Cooling,heating,
heating,ororfan
fanmode
modecan
canbe
beselected
selectedto
toprevent
prevent
Cooling,
Cooling,
heating,
or fan
modeerrors
can beduring
selected
to prevent
coolingand
andheating
heating
mixing
errors
during
seasonal
changes.
cooling
mixing
seasonal
changes.
cooling and heating mixing errors during seasonal changes
Cables used to connect a wired remote controller up to 16 indoor units
PZCWRCG3
Features
Features
Features
Features
• Indoor unit control without central controller
control
without
central
controller
•• Indoor
Indoorunit
unit
control
without
central
controller.
• Selectoperation
operationmode
mode: Cooling,
: Cooling,Heating,
Heating,Fan
Fanmode
mode
•• Select
Select
operation
mode
:
Cooling,
Heating,
Fan mode.
•
Mode
lock
for
cooling
&
heating
mixing
error-proof
lock
forfor
cooling
& heating
mixingmixing
error-proof
•• Mode
Mode
lock
cooling
&
heating
error-proof
duringthe
thechange
changeofofseason.
season.
during
during
the change
of season.
FanororOff
Off
Fan
Cooling
Cooling
ModeChange
Change
Mode
Heating
Heating
Electronic Accessories
PRDSBM
PRDSBM
PRDSBM
Air conditioner Control System
COOL///HEAT
HEATSELECTOR
SELECTOR
HEAT
SELECTOR
COOL
Model name
PZCWRCG3
Y-type cable
Long Cable
25cm length
9.6m length
Wiring Diagram
Models
ModelsApplied
Applied
Models
Applied
• MULTI V PLUS
•MULTI
MULTIVV
PLUS
• MULTI
VPLUS
WATER III, IV
•
MULTI
V
WATERIII,III,IVIV
• MULTI
V
WATER
MULTI V MINI
Indoor 1 MAIN PCB
Indoor 1
• MULTI V III, IV
• MULTIVVIII,III,IV
• MULTI
• IVMULTI V SPACE II
• MULTIVVSPACE
SPACEII II
• MULTI
• MULTIVVMINI
MINI
• MULTI
Indoor terminal block
RED (12V)
YL (SIGNAL)
BK (GND)
Indoor 2
Indoor terminal block
YL (SIGNAL)
BK (GND)
Indoor 3
Indoor terminal block
YL (SIGNAL)
BK (GND)
Wiring
WiringDiagram
Diagram
Wiring
Diagram
<OutdoorMain
MainPCB>
PCB>
<Outdoor
Push Button
Push Button
Insert wire method
Insert wire method
Push arrow direction
Push arrow direction
Shows field wiring
Shows
field wiring
Connected
wiring
Connected wiring
Insert wire to connector
Insert wire to connector
• Connect
terminals
GND)
the on the
•C
onnect
terminals
(1,
2,onon
GND)
• Connect
terminals
(1,(1,2,2,GND)
the
back
side
of
the
outdoor
dry
contact
backback
side ofside
the of
outdoor
dry contact
the outdoor
dry contact to
terminals(1,(1,2,2,GND)
GND)ofofoutdoor
outdoor
tototerminals
terminals (1, 2, GND)
of outdoor as show
showbelow.
below.
asasshow
below.
Note 1 Cable assembly for indoor units.
2 Cable assembly for connecting indoor to indoor.
- Please connect cable assembly 1 with already connected indoor unit.
* Communication
* Communicationline
linelength
lengthcan
canbebemaximum
maximum300m,
300m,
* Communication line length can be maximum 300m,
use use
communication
line line
as thick
as 1.25mm².
Communication
as thick
as 1.25mm
use communication line as thick as 1.25mm².
<OutdoorDry
DryContact
ContactBack
BackSide>
Side>
<Outdoor
* Specific set up method is referred to outdoor installation manual or PDB
* Specific set up method is referred to outdoor installation manual or PDB
44
45
ZONE CONTROLLER
ABZCA
Air conditioner Control System
Controls air conditioning in up to 4 zones
Wiring Diagram
5. Main lead wires
Features
• Controls different zones (up to 4 zones)
• Maintain proper temperature of each zone.
• Auto variation of dampers.
• Auto control of fan speed.
ROOM1
ROOM2
temperature sensor
temperature sensor
3. Case
Electronic Accessories
1. Zone Controller PCB
1
2
3
4
5
6
7
8
2. Trans
Components
temperature sensor
temperature sensor
ROOM3
ROOM4
Zone Control
sub PCB
Array of PCB & Controllers
*Central
Models Applied
Controller
Local sourcing components
Indoor Unit
*Central
Sub PCB
• Ceiling Concealed Duct (High Static Pressure)
** Main PCB
* Refer to each model PDB for applicable models
** Main PCB
Parts Included
• Ceiling Concealed Duct (High Static Pressure)
• Factory supplied
- Zone controller PCB (1EA)
- Transformer (1EA)
- Case (1EA)
- Cover (1EA)
- Main lead wires (1EA)
- Screws (1EA)
- Holder (4EA)
- Installation manual (1EA)
46
Replay
Damper
1
Thermostat 2
Replay
Damper
2
** Main PCB
Replay
Damper
3
** Main PCB
Replay
Damper
4
AC 24V
Transformer
• Purchased locally (reference siemens, honneywell)
- Damper Motor
- Thermostat
- Damper
Thermostat 1
** Wired
Remote
Controller
** IR
Remote
Controller
Outdoor Unit
47
AHU KITS (Air Handling Unit Kits)
Air conditioner Control System
Solution to connect LG outdoor unit on the DX coil of an air handing unit,
with LG's high efficient products for maximum cost saving
Selection of Evaporator
For SCAC
Detail
hen selecting evaporator, change ‘Option PCB’ in Control kit
W
according to below table (Basic ‘Option PCB is for 24k Btu/h )
Detail
PUCKA0
PRCKA0
PRDCA0
PRLK048A0
PRLK096A0
PRCKD21E
PRCKD41E
PATX13A0E PATX25A0E
PATX20A0E PATX35A0E
PATX50A0E
Specification
W
Dimensions(mm)
H
D
280
135
280
EEV Kits or Expansion Kit
280
135
280
EEV Kits or Expansion Kit
330
180
430
W
Dimensions(mm)
H
Type
Model name
Control
Comments
For Single CAC - Self sufficient
No EEV or Expansion Kit need
Communication kit
PUCKA0
PRCKA0
PRDCA0
For Multi V - Self sufficient
For Multi V - Controlled by DDC
Capacity
(Btu/h)
Allowed heat exchanger
capacity (kW)
Air flow rate
(CMM)
18K
5~6
18~21
24K
6~7
20~23
30K
7~9
22~26
36K
9~11
25~32
42K
11~13
31~35
48K
13~16
33~45
60K
20~24
42~55
* Saturated Suction Temperature (SST) = 6°C, SH (Superheat) = 5k, Air Temperature = 27°C DB / 19°C WB.
For MULTI V
Type
Model name
Control
Control.Kit
PRCKD21E
PRCKD41E
For Multi V - Total AHU control
1~4 ODU
600
750
285
For Multi V - Total AHU control
5~8 ODU
600
750
285
Type
Max Capacity
W
Dimensions(mm)
H
D
28.1kW
404
83
217
56.2kW
404
83
217
Model name
Control
Max Capacity
PRLK048A0
For Multi V - In combination with AC
system or stand alone(with 1xODU)
PRLK096A0
For Multi V - In combination with AC
system or stand alone(with 1xODU)
EEV Kit
D
• When selecting evaporator, change ‘Option PCB’ in Control kit
according to below table (Basic ‘Option PCB' is for 36k Btu/h)
• After checking the need capacity, remove the 192k Option PCB
equipped in the main PCB, and set up the Option PCB fitted the
need capacity in the main PCB.
Model name
PRLK048A0
Type
Expansion Kit
48
Model name
PATX13A0E
PATX20A0E
PATX25A0E
PATX35A0E
PATX50A0E
Control
For Multi V - Stand alone(with 1xODU)
Max Capacity
W
Dimensions(mm)
H
D
ODU Capacity : 8~16HP(23~46kW)
For Multi V - Stand alone(with 1xODU)
ODU Capacity : 18~26HP(52~75kW)
For Multi V - Stand alone(with 1xODU)
ODU Capacity : 28~36HP(82~104kW)
For Multi V - Stand alone(with 1xODU)
ODU Capacity : 38~46HP(110~133kW)
For Multi V - Stand alone(with 1xODU)
ODU Capacity : 48~56HP(139~163kW)
238
291
169
192
491
561
Detail
PRLK096A0
Option PCB
P/No
Capacity
(Btu/h)
EBR52358907
EBR52358908
Capacity setting
'Option PCB'
(Main PCB)
Maximum heat
exchanger capacity(kW)
Air flow rate
(CMM)
28k
8.6
22~26
36k
11.0
25~32
EBR52358909
42k
13.8
31~35
EBR52358910
48k
15.4
33~45
EBR52358911
76k
22.2
50~64
EBR52358912
96k
28.1
64~72
EBR52358914
115k
33.7
72~88
EBR52358915
134k
39.3
88~103
EBR52358916
155k
45.4
103~116
EBR52358917
172k
50.4
114~129
EBR52358913
192k
56.2
121~137
* Evaporator saturated temperature = 6°C, SH (Superheat) = 5K, Air Temperature = 27°C DB / 19°C WB.
49
Electronic Accessories
Capacity setting
'Option PCB'
(Main PCB)
AHU KITS (Air Handling Unit Kits)
Air conditioner Control System
Solution to connect LG outdoor unit on the DX coil of an air handing unit,
with LG's high efficient products for maximum cost saving
Combination
PRDCA0
• SCAC Application
*DDC
PUCKA0
Refrigerant Piping
Communication Wire
Sensor Signal
Dry contact
*DDC
*DDC : Digital Direct Controller
or
*DDC
*DDC : Digital Direct Controller
PQDSBC
PQDSBNGCM1
PRCKA0
Air in
(from outside)
Air
(from outside)
Dry contact
Electronic Accessories
Refrigerant Piping
Communication Wire
Sensor Signal
Air in
(from outside)
0-10V
• MULTI V Application (Stand alone)
Supply air
(to room)
Air
(from outside)
Supply air
(to room)
or
EEV
Expansion Kit
• MULTI V Application (Total AHU control for medium to large capacity)
Refrigerant Piping
Communication Wire
Thermistor (Pipe Temp.)
Signal (On/Off)
Signal (DC0 ~ 10V)
• MULTI V Application (in combination with AC system)
Dry contact
PUCKA0
Refrigerant Piping
Communication Wire
Sensor Signal
*DDC : Digital Direct Controller
*DDC
PQDSBNGCM1
Air Handling Unit
Expansion Kit
Temp. Senor / RA, SA (essential),
Mix (optional)
Temp. & Humid. Sensor/
RA, SA, OA (optional)
Air in
(from outside)
Air
(from outside)
Damper Actuator /
EA, OA, Mix (optional)
Supply air
(to room)
EEV
Differential Pressure
switch (optional)
Valve for
Humidifier (optional)
Control kit
CO2 Senor
(optional)
Smoke Detector
(optional)
Fan/ Supply, Return
Wired Remote Controller
Local
50
Control Kit
51
MECHANICAL
ACCESSORIES
ARTCOOL PANEL
A unique blend of art and colours
Panel ARTCOOL
Drain Pump Kit
> Page 53
> Page 54
Suction Grille / Canvas
Auto Elevation Grille
PSAPE**10
PSAP8**10
PSAPF**11
Models Applied
> Page 58
> Page 56
ARTCOOL Mirror
• CG : Gold
• CE : Red
• CR : Mirror
AWHP
Silver
> Page 59
Mechanical Accessories
Plasma Kit
* Panel colour
• CH : WhiteSilver • CV : Silver
Mirror
> Page 60
ARTCOOL SF Chassis
Ventilation Kit (Fresh kit)
for New Cassette
Cassette Cover
> Page 62
> Page 63
Silver
Red
Gold
White Silver
Air Guide
> Page 64
Mechanical Accessories Line up and Application
Communication kit
ARTCOOL Panel
Electric Heater
Drain Pump Kit
Suction Grille / Canvas
Auto Elevation Grille
Plasma Kit
Cassette Cover
Air guide
52
SCAC Type
MULTI Type
MULTI V Type
Remark
O
O
O
O
O
O
-
O
O
O
-
O
O
O
O
O
O
ARTCOOL indoor unit
Single package / Ducted split
Ceiling concealed duct
Ceiling concealed duct (Built-in)
4 Way Cassette
4 Way Cassette
4 Way Cassette
Outdoor unit
Model name
ARTCOL Mirror
Chassis
Colour
Mirror
Silver
Red
Gold
White Silver
ARTCOL SF chassis
SE
S8
SF
PSAPECR10
PSAP8CR10
-
PSAPECV10
PSAP8CV10
PSAPFCV11
-
-
PSAPFCG11
PSAPFCE11
PSAPFCH11
53
DRAIN PUMP KIT
Drains away condensed water
ABDPE
ABDPG
ABDPT
Application
• High head drain pump automatically drains water up to 700mm of drain-head height.
It provides perfect solution for water drainage.
ABDPE
ABDPG
ABDPT
Fixture
Drain pipe
Drain Pipe Slope (1/50~1/100)
Features
• In some places where natural drainage is not possible, a drain pump is very useful to pump out condensed water from indoor units.
• Drain pump assembly (AC 220~240V, 50/60Hz)
450mm
700mm
Mechanical Accessories
High Head Drain
Pump
Flexible Drain Hose
300mm
Models Applied
* Included in H-Inverter
* Supplied as acacessory for Standard Inverter (ABDPG)
• Ceiling concealed duct (refer PDB for applicable models)
Parts Included
• For E Chassis Models :
Accessory Model Name
• Ceiling concealed duct (refer PDB for applicable models)
Model name
Multi V Type
Multi Type
SCAC Type
54
E Chassis
ABDPE
G/H/R Chassis
ABDPG
T Chassis
ABDPT
Default
Default
Default
O
O
O
O
O
-
- Drain pump assembly (1EA)
(AC 220~240V,50/60Hz,400CMM)
- Elbow (Ø32)(1EA) - Hose (1EA)
- Tie wrap (2EA)
- Screw (10EA)
- Rubber (1EA) - Installationmanual (1EA)
• For G/H/R/T Chassis Models :
- Drain pump assembly (1EA)
(AC 220~240V,50/60Hz,400CMM)
- Screw (4EA)
- Cap (1EA)
- Installation manual (1EA)
55
SUCTION GRILLE / CANVAS
High flexibility for a wide variety of applications
PBSGB30
PBSGB40
PBSC30
PBSC40
Parts Included
• For the suction grille :
• For the suction canvas :
- Suction panel with air filter (1EA)
- Suction panel fix bolt M5x18 (4EA)
- Installation manual (1EA)
- Air suction canvas (1EA)
- Screws for air suction canvas (4EA)
- Adjusting chain (4EA)
- Screws for adjusting chain (8EA)
- Installation manual (1EA)
Features
• High external static pressure facilitates unit use with flexible ducts of varying lengths.
• When using suction panel, unit requires only 270mm of ceiling space.
• Blends unobtrusively with any interior decoration.
Models Applied
C
C
C
A
A
B
B
• Ceiling concealed duct _ Built-in type (refer block for applicable model)
A
B
(Unit : mm)
Model name
PBSGB30
PBSGB40
A
B
C
910
359
56
1188
359
56
Mechanical Accessories
Dimensions
(Unit : mm)
Model name
PBSC30
PBSC40
A
B
C
821
274
42-250
1100
274
42-250
Accessory Model Name
Grille
pbsgb30
pbsgb40
pbsc30
pbsc40
7K
O
-
9K
O
-
O
-
O
-
Capacity (Btu/h)
12K
15K
O
O
O
-
O
-
18K
-
24 K
-
O
-
O
-
O
O
Application
over 520mm
Canvas
Model name
56
over 270mm
Category
57
AUTO ELEVATION GRILLE
PLASMA KIT
Easy filter cleaning with the elevation grille
Air purifying filter to repel dust and allergens
PTEGM0
PTPKM0
PTPKQ0
Features
Features
• Easy filter cleaning with elevation grill
- Installation inside main body
- Auto horizontal control
- 4 points support structure
• It can remove microscopic contaminants such as dust and pollen to help reduce allergies.
- Memory for user’s level
- Max 4.5m length
- Model : PTEGM0 (TM, TN, TP)
Auto Horizontal Control
Memory for user’s level
Mechanical Accessories
4-Point Support Structure
Auto bottom detection
STOP
* Operating with wired remote controller PQRCVSL0 (QW) and wireless remote controller included in PTEGM0.
Models Applied
Models Applied
• 4-way cassette : Single CAC, MULTI, MULTI V (refer block for applicable models)
• 4-way cassette : Single CAC, MULTI, MULTI V (refer PDB for applicable models)
Parts Supplied
Parts Supplied
• Inlet Grille (1EA)
• Auto elevation grille kit (1EA)
• Wireless Remote Controller (1EA)
• Screws (4EA)
• Installation manual (1EA)
• Plasma Kit (1EA)
• Screws
• Installation Manual (1EA)
Application
• Auto elevation grille kit
58
• Install the kit inside
indoor unit
• Install the front panel
and the Inlet grille
• Operate the auto elevation grille by
the wireless remote controller
• Easy maintenance
59
SANITARY TANK KIT FOR
THERMA V
Solar Heating Kit
PHLLA
PHLTA (1Φ)
PHLTC (3Φ)
PHLTB
*
PHLTA / PHLTC
PHLTB
* The sensor (PHRSTA0) can be purchased separately in case of using other brand’s sanitary tank.
Features
Features
• Easy to install sanitary water tank for monobloc. There is a MCCB to protect the product.
• Dimensions (HXWXD, mm) : 250x170x110
• Weight (kg) : 2.1
• Interface for solar-thermal system with split-type THERMA V and double coil sanitary tank.
• Installed at the water pipe, between sanitary tank and solar-thermal system.
• Dimensions (HXWXD, mm) : 110x55x22
Mechanical Accessories
To extend THERMA V functionality in generating domestic hot water.
Only applied to split-type THERMA V.
* To be installed inside THERMA V indoor unit.
Combination
Combination
• Components : THERMA V system, PHLTA, PHLTC, and field-supplied items.
• Components : THERMA V system, PHLTA, PHLTC, and field-supplied items.
Outdoor
Indoor
Outdoor
Outdoor Unit
Indoor
Outdoor Unit
Indoor Unit
Indoor Unit
Fan Coin Unit
Hot Water
City Water
Floor Heating Loop
Hot Water
Radator
Sanitary
Water
Tank
City Water
Solar Heat
Source
60
Fan Coin Unit
Floor Heating Loop
Radator
Sanitary
Water
Tank
61
VENTILATION KIT
CASSETTE COVER
Fresh air can be supplied from outside through this ventilation kit
Air purifying filter to prevent dust and allergens
PTVK410
PTVK420
PTVK430
PTDCM
PTDCQ
PTVK410
PTVK420
PTVK430
Features
• PTVK410 : 1 Ventilation Kit, 8 Bolts, 1 Insulation
• PTVK420 : 1 Flange, 7 Screws
• PTVK420 : 1 Flange, 4 Screws, 1 Insulation
• Specially designed for indoor unit.
• Covers the side area of cassette.
• Gives elegant looks.
• Light weight.
• Suitable when false ceiling is unavailable.
Models Applied
Mechanical Accessories
Features
Models Applied
• There are 2 solutions for Fresh air
- PTVK410+PTVK420 (for chassis TP, TN, TM)
- PTVK430 (for chassis TR, TQ, TP, TN, TM)
• 4-way cassette (TP, TN, TM, TQ, TR)
* Users can purchase and use PTVK430 in addition to PTVK410+PTVK420 in need to phase in larger outdoor air volume.
Dimensions
Parts Supplied
Assembly Diagram
• Cover A (4EA), Cover B (4EA)
• Cover C (4EA), Cover D (4EA)
• Screws
• Installation Manual (1EA)
406
4
840
435
443
81
13
Accessory Model Name
PTVK430
Model name
PTDCM
419
Front Panel
PT-UMC/
PT-UMC1
840
55mm
62
PTVK410+PTVK420
PTDCQ
NET
Weight (kg)
Gross
W
Dimensions (mm)
H
D
TP/TN
5.9
8.8
1,157
1,157
268
TN
5.9
8.8
1,157
1,157
310
TR
5.0
7.2
907
907
268
TQ
5.0
7.2
907
907
310
PT-UQC
63
AIR GUIDE
Air discharge in difficult to access areas
PRAGX*SO
Application
Features
564
512
• MULTI V IV (UX2, UX3)
33
512
Models Applied
* In case of UX3, must purchase 2 units of PRAGX3SO.
00
R6
652
45
50
632
Mechanical Accessories
• Converts vertical discharge into horizontal discharge.
• Designed for outdoor discharge air.
• Direction of air discharge can be changed by simple installation.
• Installation flexibility.
618
MULTI V IV (UX2)
0
564
12.3kg
PRAGX3S0
17kg
632
9.4kg
564
564
618
50 512
512
652
50
00
R6
652
652
618
0
3333
60
900
0
00 00
R6 R6
652
00
R6
50
652
500
512
512
512
512
60
500
22.5kg
632
652
652
45
45
50
5050
632
632
570
832
570
618618
50
PRAGX2S0
50
570
MULTI V IV (UX3)
MULTI V IV (UX3)
45
Net Weight
45
Gross Weight
00
R6
45
Model name
33
512
564
512
Dimensions
60
33
760
0 0
60 60
832
900
718
900
760
904
900
900
500
500
500
500
718
00 00
R6 R6
500
718
50
50
45
45
762
64
2
50
832
832
832
832
760
45
45
50
832
832
45
R6
R6
762
500
00
500
570
570
500
00
50
50
652
652
MULTI V IV (UX2)
760
760
65
PIPING
ACCESSORIES
Y Branch and Header Branch
(Synchro)
Refrigerant distribution channel
2 Units
Y Branch & Header
Branch (Synchro)
Branch Distributor
> Page 67
> Page 68
Y Branch & Branch Kit
(MULTI F DX)
Refrigerant Charging Kit
> Page 70
> Page 71
PMUB11A
3 Units
PMUB111A
Heat Recovery Unit
> Page 72
> Page 74
Drain Hose
Drain Pan
> Page 76
> Page 77
PMUB1111A
Gas Pipe
Liquid Pipe
Features
• Various Y-branch pipes of different capacities make installation easier.
• Y-branch and header branch for both gas and liquid are provided.
• Insulation material is also provided for covering the branches.
Models Applied
Dimensions
• Synchro
Piping Accessories
Stopper Valve
4 Units
Y Branch & Header
Branch (MULTI V)
> Page 78
2 branch
3 branch
4 branch
Accessory Model Name
Category
Mechanical Accessories Line up and Application
Model name
Y Branch and Header Branch (Synchro)
Branch Distributor (MULTI)
Heat Recovery Unit
Y Branch and Branch Kit (MULTI)
Y Branch and Header Branch (MULTI V)
66
SCAC Type
MULTI Type
MULTI V Type
Remark
O
-
O
O
-
O
O
Synchro
MULTI Fdx
MULTI V Sync II / MULTI V III Heat Recovery
MULTI Fdx
MULTI V Heat Pump / Heat RecoveryMULTI V Space / MULTI V Mini
2 Units
3 Units
4 Units
Model name
Gas pipe
Liquid pipe
(1:1)
(1:1)
(1:1:1)
(1:1:1)
(1:1:1:1)
(1:1:1:1)
PMUB11A
PMUB111A
PMUB1111A
67
Branch Distributor
(Distributor Box)
Effective way of distributing refrigerant.
Parts Supplied
PMBD3620
PMBD3630
PMBD3640
• BD (Banch Distributor) unit (1EA)
• Brackets (4EA)
• Screws (8EA)
• Installation Manual (1EA)
PMBD3620
PMBD3630
PMBD3640
Features
No brazing
Just flaring
• Distribution of refrigerant to various indoor units.
• 3 models (2, 3, 4 indoor units)
• Consists of LEVs inside it.
• Controlling PCB inside the unit.
• Internally insulated (prevents any chances of drainage)
• Flare joints for easy and clean installation.
• Compact design (low height)
• Flexible installation.
Specification
(R410A)
• MULTI F DX systems (refer PDB for applicable models)
Model name
Connectable
Capacity
Casing colour
Number of Indoor unit
(Btu/hr)
Power source
Installation
• Position of branch distributor in the system.
• PDB (Select) - Installation PDB.
Power consumption
Running current
Dimensions
Packing dimensions
Net weight
Connecting cable
Piping connection
(Outdoor unit)
Piping connection
(Indoor unit)
Parts
68
Piping Accessories
Models Applied
(W x H x D)
(W x H x D)
(W)
(A)
(mm)
(mm)
Indoor unit No. x mm²
Outdoor unit No. x mm²
liquid
(mm)
Gas
(mm)
Liquid
(mm)
Gas
(mm)
Hanger
(EA)
Screw
(EA)
Manual
(EA)
PMBD3620
PMBD3630
1~2
1~3
PMBD3640
1~4
5k/7k/9k/12k/18k/24k
5k/7k/9k/12k/18k/24k
5k/7k/9k/12k/18k/24k
Paintingless
Paintingless
Paintingless
1ø, 50/60Hz,
220~240/220B
1ø, 50/60Hz,
220~240/220B
1ø, 50/60Hz,
220~240/220B
10
10
10
0.05
0.05
0.05
302x143x252
302x143x252
302x143x252
422x202x300
422x202x300
422x202x300
4.8
4.9
5.0
4x0.75
4x0.75
4x0.75
4x0.75
4x0.75
4x0.75
9.52
9.52
9.52
19.05
19.05
19.05
6.35x2
6.35x3
6.35x4
9.52x2
9.52x3
9.52x4
4
4
4
8
8
8
1
1
1
69
Y Branch and Branch Kit
multi f dx
REFRIGERANT CHARGING KIT
Recharge refrigerant after a pump down or when refrigerant is either
insufficient or excessive
Refrigerant distribution channel
PRAC1
2 Units
PMBL3620
PMBL5620
2 Units
PMBL1203F0
Features
Models Applied
Procedure
• Y Branch and Branch kit make Multi F DX installation easier.
• Y-Branch and Branch kit for both gas and liquid are provided.
• Insulation material is also provided for covering the branches.
• MULTI F DX, 1ø, 3ø
• Arrange manifold, capillary assembly, refrigerant vessel and scale.
• Connect manifold to the gas pipe service valve of outdoor uint as shown in the figure.
• Connect manifold and capillary tube. Use designated capillary assembly only. If designated capillary assembly isn’t used,
the system may get damaged.
• Connect capillary and refrigerant vessel.
• Purge hose and manifold.
• After “568” is displayed, open the valve and charge the refrigerant
Application
Models Applied
• MULTI V III
Mainfold
Piping Accessories
Capillary Assembly
Parts Supplied
* Fault Detect & Diagnosis
• Y Branch for Gas side and Liquid side (1 set)
• Installation manual (1EA)
Accessory Model Name
Refrigerant
(Unit : mm)
Model name
No. of BD units
Specification
Applicable Model
Gas
Ø15.88
Ø15.88
Ø15.88
Ø15.88
Liquid
Ø6.35
Ø6.35
PMBL3620
2 units
Only 3ø, 36k Btu/h
Ø15.88
Ø15.88
Ø15.88
Ø15.88
Ø6.35
Ø6.35
Ø6.35
Ø6.35
Ø6.35
Ø6.35
Ø15.88
Ø15.88
PMBL5620
2 units
1ø, 3ø
Ø19.05
Ø19.05
Ø19.05
Ø19.05
Ø19.05
Ø19.05
Ø19.05
Ø19.05
Ø9.52
Ø9.52
Ø9.52
Ø9.52
Ø9.52
Ø9.52
Ø9.52
Ø9.52
Ø9.52
Ø9.52
Ø19.05
Ø19.05
PMBL1203F0
3 units
1ø, 3ø
70
Ø9.52
Ø9.52
Ø19.05
Ø19.05
Ø19.05
Ø19.05
Ø9.52
Ø6.35
Ø6.35
Ø6.35
Ø6.35
Ø15.88
Ø15.88
Ø9.52
Ø9.52
Error Contents about Auto Refrigerant Charging Function
• “329” : Temperature Range Error (In case that indoor unit or outdoor unit is out of range)
• “339” : Low Pressure Descent Error (In case the system runs at low pressure limit for over 10 minutes)
• “349” : Rapid refrigerant inflow (In case the liquid refrigerant flows in because of not using designated capil-lary assembly)
• “359” : Instability Error (In case the high/low pressure target doesn’t get satisfied for some time after the starting operation)
Ø9.52
71
STOPPER VALVES
Under 1/2 (inch)
PRVT120
Details of Model Name
Under 9/8 (inch)
PRVT980
• case1
(Room 3 & 4 : in use / Room 1 & 2 : need to install indoor units)
Cut inlet side of the connector, and weld
the pipe
Under 7/8 (inch)
PRVT780
In case of the installation of additional
indoor unit, outlet side connector should
be cut according to installation pipe.
* Stopper Valve is already installed
"A"
Features
9.52 : 19.05
Room 1
3.0m
Model name
9.52 : 19.05
Spec
Closed
state
Pin(Closed)
3.0m
Pin(Open)
Stopper valves
9.52 : 15.88
In case of installation of stopper valve,
In case of installation of additional
flare part should be facing towards 10.0m indoor unit, SVC valve should be in
additional indoor unit.
closed state
PRVT120
Room 2
-When welding, service valve shoud be wrapped9.52
by :wet
15.88cloth.
5.0m
PRVT780
Room 3
6.35 : 12.7
3.0m
Room 4
Piping Accessories
• In case of installation of additional indoor unit, refrigerant of used indoor unit must be discharged.(Room3 & Room4)
• If stopper valve is already installed, you can install additional indoor unit without refrigerant loss from the entire system.
• After installation of additional
indoor
unit,connector,
you just need
refrigerant
charging
for “A” section.
In case
of the installation
of additional
Cut inlet side
of the
and weld
• Then, open the Stopper
theValve.
pipe
indoor unit, outlet side connector should
PRVT980
be cut according to installation pipe.
Open/close port
Usage
9.52 : 19.05
• This unit can be applied for the additional indoor unit’s installation.
• This unit can be applied for each indoor unit’s service.
3.0m
9.52 : 19.05
Pin(Closed)
Stopper Valves
3.0m
Installation
Charge port
case ofInthe
installation
of additional
Cut inlet Cut
sideinlet
of the
connector,
and weldand In
case
of the installation
of additional
side
of the connector,
weld
the pipe the pipe
indoor unit,
outlet
side
connector
should should
indoor
unit,
outlet
side connector
be cut according
to
installation
pipe.
be cut according to installation
pipe.
: 15.88
In case of installation of 9.52
stopper
valve,
flare part should be facing towards
additional indoor unit.
10.0m
Open
state
Pin(Open)
In case of installation of additional
indoor unit, SVC valve should be in
closed state
6.35 : 12.7
3.0m
-When welding, service valve shoud be wrapped by wet cloth.
Room 1
9.52 : 15.88
3.0m
Pin(Closed)
Pin(Closed)
of the
installation
of units,
additional
inlet
sideside
of of
the
connector,
andand
weld
1.Cut
CutCut
theinlet
inlet
connector,
and
case
ofadditional
the
installation
of additional
side
ofthe
the
connector,
weld In2.case
IIn
f installing
indoor
the outlet
the
pipe
indoor
unit,unit,
outlet
side connector
should
the
pipe
indoor
outlet
connector
weld
the
pipe
side
connector
shouldside
be cut
according should
to
be be
cutcut
according
to installation
pipe.
according
to installation
pipe.
installation pipe.
* When welding, service valve shoud be wrapped by wet cloth.
Pin(Open)
Pin(Open)
3.When
installing
a stopper
valve, thevalve,
flare part In case of installation
4. When installing
anadditional indoor unit,
In
case of
of stopper
of additional
Ininstallation
case of installation
of stopper valve,
In case of installation
of additional
should
facing towards
additional
indoor unit.
the SVC
should
beinin closed state.
flare
partbe
should
facing
towards
SVC
valvevalve
should
flare
partbeshould
be
facing towards indoor unit,
indoor
unit,
SVC
valvebeshould
be in
additionaladditional
indoor unit.
closed state
indoor unit.
closed state
Room 2
Room 3
-When welding,
service valve
shoud
wrapped
by wet cloth.
-When welding,
service
valvebeshoud
be wrapped
by wet cloth.
Room 4
Pin(Closed)
Pin(Closed)
72
In case
of installation
of stopper
valve,
In case
of installation
of stopper
valve,
flareflare
partpart
should
be be
facing
towards
should
facing
towards
additional
indoor
unit.unit.
additional
indoor
Pin(Open)
Pin(Open)
In case
of installation
of additional
In case
of installation
of additional
indoor
unit,unit,
SVC
valve
should
be be
in in
indoor
SVC
valve
should
closed
state
closed
state
73
Heat Recovery Unit
PRHR021
PRHR031
PRHR041
Reducers for Indoor Unit and HR Unit
PRHR021
(2 branch Unit)
PRHR031
(3 branch Unit)
PRHR041
(4 branch Unit)
Gas pipe Gas pipe
(Unit : mm)
Models Models Liquid pipe
Liquid pipe
pipe
Gas
pipe Gas
Gas pressure
pipeHigh
pressure
Low pressure
High
Low
pressure
Models
Gas
pipe
Models
Models
Liquid
pipe
Liquid
pipe
Gas
pipe
Gas
pipe
Liquidpipe
pipe
Model name
Liquid
HighGas
pressure
Low
pressure
pipeHigh
Models
pressure
Low pressure
High pressure
Low pressure
Highpipe
pressure
Low
pressure
Liquid
Models
Models
Liquidpipe
pipe
Liquid
Models
High
pressure
Low pressure
Liquid
pipe
High
pressure
Low
pressure
High
pressure
Low
pressure
Indoor unitIndoor unit
High pressure
Low pressure
OD9.52 Ø6.35 OD9.52 Ø6.35
reducer
unit
reducer
unit Indoor
Indoor unit Indoor
OD15.88
Ø12.7
OD15.88
Ø12.7
Indoor unit reducerIndoor
Indoor
unit OD9.52 Ø6.35 OD9.52 Ø6.35
Indoorreducer
unit
unit
Ø6.35
reducer
reducer OD9.52
Indoor unit
OD15.88
Ø12.7
Ø12.7
OD15.88
Ø12.7OD15.88
OD9.52
Ø6.35
reducer
OD9.52Ø6.35
Ø6.35
OD9.52
reducer
reducer
OD15.88
Ø12.7
OD15.88
Ø12.7
OD15.88
Ø12.7
OD9.52 Ø6.35
reducer
OD15.88
Ø12.7
Ø12.7 OD22.2 Ø19.05OD22.2
Ø15.88Ø19.05
Ø15.88
Ø15.88OD19.05
Ø12.7
Ø15.88 OD19.05
Ø12.7
OD9.52 Ø6.35
OD22.2 Ø19.05 OD22.2
Ø15.88 Ø19.05
OD9.52 Ø6.35OD19.05
OD22.2Ø15.88
Ø19.05 Ø12.7
Ø15.88
PRHR020
PRHR020
OD19.05Ø19.05
Ø15.88
Ø12.7
OD22.2 Ø19.05
OD19.05 Ø15.88
Ø15.88 Ø12.7
Ø12.7
OD19.05
OD22.2
Ø19.05
Ø15.88
OD22.2
Ø15.88
PRHR020
OD9.52 Ø6.35
OD9.52 Ø6.35 OD19.05
OD9.52 Ø6.35
Ø15.88 Ø12.7
OD22.2 Ø19.05 Ø15.88
OD9.52 Ø6.35
OD9.52Ø6.35
Ø6.35
OD9.52
OD12.7
Ø9.52
OD12.7
Ø9.52
OD9.52 Ø6.35
OD15.88
OD15.88
Ø12.7
Ø15.88
Ø15.88
OD19.05
PRHR020 PRHR020
Features
PRHR021
• Max. 32 indoor units can be connected (Max 8 indoor units per branch)
• Due to the automatic search algorithm for piping detection, easy installation.
• Subcooling cycle in HR unit makes the system efficiency maximum.
HR unit
HRunit
unit
HR
reducer
HR unit
reducer
reducer
reducer
HR unit
reducer
PRHR031/
PRHR041
Models Applied
• MULTI V WATER II Heat Recovery
• MULTI V III Heat Recovery
• MULTI V SYNC
• MULTI V SYNC II
PRHR020
PRHR020
PRHR020
PRHR020
HR unit
reducer
HR
unit
reducer
PRHR030
PRHR030/
PRHR030
PRHR030
/
/ PRHR040
/
PRHR040
PRHR040
PRHR040
HR unit
reducer
HR
unit
HR unit
reducer
reducer
OD15.88 Ø12.7OD15.88 Ø12.7
Specification
OD15.88 Ø12.7
Ø12.7
Ø12.7
Ø12.7
OD28.58
Ø22.2
Ø19.05Ø22.2
Ø19.05
Ø22.2 OD28.58
Ø19.05 Ø22.2
OD28.58
Ø22.2
Ø19.05
Ø19.05
OD19.05
OD19.05
OD15.88
Ø12.7 Ø15.88 OD19.05
OD19.05 Ø12.7
Ø15.88
OD19.05
Ø15.88
OD15.88
OD19.05 Ø15.88
OD19.05
Ø15.88
Ø15.88
Ø15.88 OD19.05
OD19.05
Ø15.88
Ø15.88
EA
kW
EA
kW
kW
kg
mm
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
ø /V/Hz
PRHR021
PRHR031
2
3
PRHR041
4
16/32
16/48
16/58
8
8
8
0.026
0.040
0.040
0.026
0.040
0.040
18
20
22
801x218x617
801x218x617
801x218x617
9.52 (3/8)
9.52 (3/8)
9.52 (3/8)
15.88 (5/8)
15.88 (5/8)
15.88 (5/8)
9.52 (3/8)
15.88 (5/8)
15.88 (5/8)
28.58 (11/8)
22.2 (7/8)
28.58 (11/8)
19.05 (3/4)
22.2 (7/8)
22.2 (7/8)
1 / 220~240 / 50
1 / 220~240 / 50
1 / 220~240 / 50
Kitchen
Office
• Individual Control
Piping Accessories
74
OD15.88 Ø12.7
OD15.88 Ø12.7
Ø12.7
OD15.88
OD15.88 Ø12.7
Ø12.7OD15.88
OD15.88
MULTI V III Heat recovery provides flexible control over
individual zones for the user’s convenience.
- Perfect individual control over spaces ventilation needed
• Zone Control
- Max. of 8 indoor units can be connected for one branch
- Max. of 32 indoor units can be connected for one HR unit
-Same opeational model can be operated by indoor units
with zone control function installed
• Combination of Individual and Zoning Installations
- Flexible piping design
• Save Product and Installation Cost
Room
[Zoning control]
Dimensions
• HR unit (1EA)
• Hanging bolts M10 or M8 (4EA)
• Nut M8 or M10 (8EA)
OD12.7
Ø9.52
Ø9.52
OD15.88
Ø12.7 OD15.88
OD12.7
Ø9.52
OD15.88 Ø12.7
Ø12.7
OD15.88
OD15.88
Ø12.7
OD12.7
Ø9.52OD12.7
OD12.7
Ø9.52
OD12.7
Ø9.52
OD12.7
Ø9.52
PRHR030 PRHR030
Ø9.52
Ø9.52 Ø12.7
OD22.2 Ø19.05OD22.2
Ø15.88Ø19.05 Ø15.88
/ OD15.88 Ø12.7 OD15.88
/
OD28.58
PRHR030
PRHR030
PRHR040
PRHR040
OD15.88
Ø12.7 Ø15.88
Ø9.52 Ø19.05 OD22.2
OD15.88 Ø12.7 OD22.2
Ø9.52 Ø19.05
OD22.2
Ø15.88 Ø19.05 Ø15.88
PRHR030
/ Ø9.52
/OD15.88 Ø12.7
OD28.58
Ø22.2 OD28.58
Ø19.05
OD22.2 Ø19.05 Ø15.88
/
OD15.88Ø12.7
Ø12.7 PRHR040
Ø9.52
OD22.2OD15.88
Ø19.05Ø12.7
Ø15.88Ø9.52
OD15.88
Ø9.52
OD22.2
Ø19.05
Ø15.88
PRHR040
OD28.58 Ø22.2
Ø22.2 Ø19.05
Ø19.05
OD28.58
OD15.88 Ø12.7
Ø9.52
OD22.2 Ø19.05 Ø15.88
PRHR040
OD28.58
Ø22.2
Ø19.05
Convenient Free Zoning
Model name
Number of branch
Maximum connectable capacity of indoor units (Per branch/unit)
Maximum number of connectable indoor units per branch
Cooling
Nominal Input
Heating
Net. Weight
Dimensions (WxHxD)
Liquid
Indoor Unit
Gas
Piping
Liquid
connections
Outdoor Unit
Low pressure
High Pressure
Power Supply
OD19.05
Ø15.88
Ø12.7Ø15.88
IT Room
HR unit
• Washers M10 (8EA)
• Reducers
Zoning Control (Max Indoor unit 8EA)
75
DRAIN HOSE
DRAIN PAN
Easy drain installation
Easy drain installation
PHDHA05T
PHDHA07T
PHDHA05B
PHDHA07B
PRODX20
PRODX30
Features
Features
It reduces the installation time by over 40% with elbow-less drain hose.
Midget drain pump covers maximum 800mm high, featuring easy piping installation.
This unit can be applied for outdoor unit’s drain.
Installation
Standard
Models applied to Ceiling Cassette,
Ceiling Concealed Duct.
(refer PDB for applicable model.)
Max. 450
* Tuck drain pan below base pan
250
Piping Accessories
Service Valve
1 Way, 4 Way Ceiling Cassette,
Concealed Duct
(with drain pump)
Flexible Hose
Make a loop form
Drain Pipe
(Unit : mm)
* Push drain pan in the direction of the arrow.
Brackets can be fixed on the side panel.
• This unit does not cover water drops of the outside product.
• Connect drain hose to drain pipe for drain condensate.
Accessory Model Name
76
* In case of the installation of drain pan, drain pipe should be located below the SVC valve.
Model name
Length
Quantity
PHDHA05T
PHDHA07T
PHDHA05B
PHDHA07B
500mm
30EA
700mm
30EA
500mm
5EA
700mm
5EA
Accessory Model Name
Model name
L
PRODX20
PRODX30
920mm
Remark
UX2
1240mm
UX3
77
Y BRANCH AND HEADER
BRANCH (
)
For refrigerant distribution of indoor units
Accessory Model Name
Header Branch
• R410A
(Unit : mm)
Model name
Y Branch
Gas pipe
Liquid pipe
Header Branch
4 branch / ARBL054
Features
• Various Y-branch pipe of different capacities make MULTI V installation much easier.
• Y-branch and header branch for both gas and liquid are provided.
• Insulation material is also provided for covering the branches.
7 branch / ARBL057
Piping Diagram
4 branch / ARBL104
Piping Accessories
Header Branch
Y- branch
7 branch / ARBL107
Outdoor unit
10 branch / ARBL1010
Models Applied
• MULTI V PLUS
• MULTI V PLUS II
• MULTI V III
78
• MULTI V IV
• MULTI V MINI
• MULTI V SPACE II
• MULTI V SPACE III
• MULTI V WATER II
• MULTI V WATER IV
• MULTI V Heat Recovery
10 branch / ARBL2010
79
PIPING ACCESSORIES
• R410A / MULTI V III, MULTI V IV, MULTI V MINI, MULTI V SPACE II
• R410A / MULTI V III Heat Recovery, MULTI V IV Heat Recovery
(Unit : mm)
(Unit : mm)
2 Outdoor Units
Model name
Low Pressure Gas pipe
Liquid pipe
416
408
416
408
C
ARCNN21
C
C
C
ARCNN21
111
I.D.22.2
I.D.31.8 I.D.34.9
I.D.12.7
I.D.22.2I.D.9.52111 83
I.D.41.3
I.D.38.1
O.D.34.9
I.D.22.2
O.D.19.05
C
C
298
C
ARCNN31
C
B
ARCNN31
C
ARCNN21
I.D.34.9
I.D.28.58
O.D.34.9
111
111
I.D.22.2
I.D.28.58
125
I.D.41.3 I.D.38.1 O.D.34.9
Low Pressure
GasI.D.28.58
pipe
415
A
ARCNN41
A
BB
ARCNN31
B C C
ARCNN21
C
416
408
I.D.31.8 I.D.34.9
C
Model name
B
I.D.41.3
375
130
C
I.D.41.3
I.D.28.58
I.D.41.3
298
416
408
I.D.41.3
134
B
ARCNN31
C
ARCNN21
I.D.28.58
I.D.34.9
I.D.28.58
111
O.D.34.9
111
I.D.22.2
I.D.28.58
I.D.31.8 I.D.34.9
I.D.28.58I.D.15.88
I.D.22.2
I.D.19.05
I.D.41.3
C
B
Model name
298
I.D.41.3
125
I.D.22.2
O.D.19.05
I.D.41.3
I.D.38.1
O.D.34.9
C
B
C
A
80
B
I.D.44.48 I.D.53.98
C
I.D.15.88 I.D.12.7
I.D.41.3
134
111
334 pipe
Liquid
I.D.41.3
I.D.15.8880
I.D.28.58
I.D.22.2 I.D.19.05
O.D.34.9
I.D.19.05134
I.D.41.3
416 331
408 314
83
I.D.15.88 I.D.12.7
I.D.28.58
I.D.34.9
I.D.15.88111
I.D.28.58
83
I.D.19.05
I.D.41.3
O.D.34.9
I.D.19.05
I.D.31.8 I.D.34.9
I.D.22.2
341
I.D.22.2 I.D.19.05
298 334
I.D.44.48 I.D.53.98
281
I.D.25.4 O.D.22.2
4 I.D.41.3
Outdoor Units
I.D.19.0580
334
415
281
375
I.D.22.2
I.D.22.2 I.D.19.05
I.D.44.48 I.D.53.98
I.D.25.4 O.D.22.2
80
Liquid pipe
High Pressure Gas pipe
341
298
83
I.D.15.88
I.D.19.05
ARCNB31
83
I.D.12.7 I.D.9.52
I.D.19.05
I.D.34.9
I.D.41.3
416
408
I.D.22.2 O.D.19.05
I.D.19.05
I.D.41.3I .D.38.1 O.D.34.9
O.D.34.9
I.D.28.58
I.D.15.88 I.D.12.7
130
125
I.D.12.7
111
83
83
I.D.28.58
I.D.28.58
I.D.22.2
I.D.31.8 I.D.34.9
111
I.D.22.2 I.D.19.05
I.D.15.88 I.D.12.7
I.D.12.7
I.D.15.88
I.D.28.58
I.D.28.58
334
281
I.D.15.88 I.D.12.7
331
314
80
I.D.15.88
I.D.19.05
I.D.15.88
334
70
I.D.19.05
134
I.D.41.3
83
I.D.22.2
281
I.D.19.05
334
I.D.25.4 O.D.22.2
I.D.15.88 I.D.12.7
I.D.34.9
111
I.D.28.58
83
I.D.19.05
I.D.19.05
83
281
I.D.15.88 I.D.12.7
I.D.22.2
I.D.19.05
80
4 Outdoor Units
83
I.D.19.05
Liquid pipe
I.D.15.88 I.D.12.7
Model name
Low Pressure Gas pipe
334
I.D.19.05
I.D.41.3
134
83
I.D.22.2
I.D.19.05
I.D.19.05
83
I.D.25.4 O.D.22.2
I.D.28.58
Liquid pipe
ARCNB41
I.D.44.48 I.D.53.98
I.D.41.3
134
I.D.22.2 I.D.19.05
341
298
I.D.19.05
83
I.D.25.4 O.D.22.2
I.D.15.88 I.D.12.7
80
High Pressure Gas pipe
334
281
415
375
281
I.D.15.88 I.D.12.7
I.D.28.58
Low Pressure Gas pipe
334
I.D.25.4 O.D.22.2
281
I.D.28.58 I.D.12.7
I.D.15.88
415
134
Model name
O.D.34.9
125
I.D.41.3
I.D.19.05
I.D.19.05
334
125
A
ARCNN41
I.D.15.88
I.D.41.3
I.D.12.7 I.D.9.52 11183
I.D.22.2
I.D.28.58
I.D.15.88 I.D.12.7
125
I.D.22.2I.D.38.1
I.D.41.3
O.D.34.9
O.D.19.05
I.D.41.3
I.D.12.7
3 Outdoor Units
281
281
I.D.25.4 O.D.22.2
I.D.22.2
83
I.D.19.05
I.D.15.88
I.D.22.2 O.D.19.05
I.D.12.7
I.D.28.58 I.D.15.88
334
Low Pressure GasI.D.28.58
pipe
A
ARCNN41
83
I.D.19.05
I.D.19.05
I.D.15.88
70
I.D.22.2 I.D.19.05341
I.D.44.48 I.D.53.98 298
375
ARCNN41
I.D.22.2
I.D.12.7
70
I.D.12.7 I.D.9.52
83
I.D.15.88 I.D.12.7
I.D.19.05
281
130
70375
A
ARCNN41
B
ARCNN31
331
314
I.D.22.2 I.D.15.88
I.D.19.05
70
130
415
I.D.34.9
I.D.28.58
I.D.41.3
I.D.22.2 O.D.19.05
83
Piping Accessories
B
C
341
83
I.D.12.7 I.D.9.52
83
111
I.D.22.2
I.D.28.58
I.D.15.88 I.D.12.7
I.D.19.05
I.D.28.58
I.D.44.48 I.D.53.98
I.D.12.7 I.D.9.52
I.D.19.05
O.D.34.9
3
Outdoor
I.D.31.8
I.D.34.9 Units
375
130
B
331
314 I.D.34.9
111
I.D.15.88
I.D.28.58
I.D.19.05
416
408
I.D.41.3
415
A
ARCNN41
B
A
B
C
ARCNN31
334
281
I.D.15.88
281
281
125
I.D.41.3 I.D.38.1 O.D.34.9
C
I.D.28.58
High Pressure Gas pipe
334
334
415 334
375 281
A
ARCNN41
341
I.D.44.48 I.D.53.98
111
130
70
331
314
I.D.15.88
I.D.28.58
I.D.22.2
I.D.31.8 I.D.34.9
I.D.41.3I .D.38.1 O.D.34.9
I.D.15.88
Liquid pipe
341
298
I.D.41.3
I.D.28.58
I.D.12.7
I.D.28.58I.D.15.88
I.D.12.7
416
408
83
ARCNB21
130
70
341
B
ARCNN31
BC
C
ARCNN21
Low Pressure Gas pipe
I.D.28.58
I.D.12.7 I.D.9.52
I.D.19.05
I.D.22.2 O.D.19.05
I.D.28.58
130
I.D.15.88
I.D.15.88
I.D.28.58
I.D.15.88
I.D.19.05
I.D.31.8 I.D.34.9
I.D.41.3 I.D.38.1 O.D.34.9
Model name
331
314
331
314
I.D.28.58
I.D.15.88
I.D.28.58
I.D.28.58
ARCNN21
2 Outdoor Units
I.D.34.9
I.D.41.3
I.D.41.3
I.D.15.88 I.D.12.7
I.D.28.58
80
111
O.D.34.9
I.D.28.58
125
81
PIPING ACCESSORIES
• R410A / MULTI V PLUS, MULTI V PLUS II, MULTI V III, MULTI V IV, MULTI V MINI, MULTI V SPACE II,
• R410A / MULTI V III Heat recovery, MULTI V IV Heat recovery, MULTI V WATER II Heat recovery
MULTI V WATER II, MULTI V WATER IV
Model name
(Unit : mm)
Gas pipe
MULTI V WATER IV Heat recovery
Model name
Liquid pipe
(Unit : mm)
Low Pressure Gas pipe
Liquid pipe
I.D9.52
I.D9.52
ARBLB01620
I.D6.35
ARBLN01621
I.D6.35
I.D15.88
ARBLB01621
I.D12.7
I.D15.88
I.D19.05
ARBLB01620
I.D15.88
I.D. 15.88
I.D15.88
ARBLB01620
O.D15.88
O.D9.52
I.D22.2
I.D19.05
I.D9.52
I.D19.05
I.D15.88
I.D25.4
ARBLN03321
I.D12.7
I.D12.7
I.D22.2
O.D19.05
I.D28.58
I.D19.05
I.D9.52
ARBLB03321
O.D19.05
I.D28.58
I.D12.7
I.D15.88
I.D. 15.88
O.D. 22.2
ARBLB03320
I.D12.7
I.D19.05
I.D. 15.88
O.D. 22.2
O.D. 28.58
I.D. 25.4
O.D. 22.2
O.D. 28.58
I.D. 25.4
I.D 22.2
• R410A / MULTI V PLUS, MULTI V PLUS II, MULTI V III, MULTI V IV, MULTI V WATER II,
MULTI V WATER IV, MULTI V MINI, MULTI V SPACE II
(Unit : mm)
I.D22.2
Model name
Gas pipe
Liquid pipe
I.D28.58
I.D22.2
I.D19.05
I.D19.05
I.D15.88
I.D15.88
I.D12.7
I.D15.88
I.D12.7
I.D15.88
O.D22.2
I.D31.8
I.D28.58
I.D34.9
O.D19.05
ARBLN07121
I.D31.8
ARBLB07120
I.D28.58
O.D31.8
I.D12.7
I.D22.2
I.D12.7
I.D19.05
I.D19.05
I.D15.88
ARBLB07120
I.D19.05
O.D19.05
I.D28.58
I.D22.2
I.D. 41.3
I.D34.9
I.D41.3
I.D34.9
I.D41.3
I.D38.1
I.D38.1
I.D28.58
41.3 I.D. 12.7
O.D.I.D.
19.05
I.D. 34.9
I.D. 15.88
I.D28.58
I.D38.1
ARBLN14521
I.D34.9
I.D41.3
I.D41.3
O.D38.1
I.D22.2
O.D38.1
I.D38.1
O.D34.9
ARBLB14520
I.D19.05
I.D12.7
I.D19.05
O.D28.58
O.D15.88
I.D12.7
I.D15.88
O.D15.88
I.D19.05
I.D22.2
I.D22.2
ARBLB14520
ARBLB14520
I.D. 9.52
O.D. 12.7
I.D. 19.05
X2
MULTI V MINI, MULTI V SPACE II
(Unit : mm)
Model name
I.D. I.D.
19.05
15.88
I.D. 12.7
O.D. 9.52
I.D.6.35
19.05
I.D.
I.D.53.98
Model name
Gas pipe
Liquid pipe
I.D.44.48
I.D41.3
I.D.34.9
I.D31.8
O.D.38.1
ARBLN23220
I.D.28.58
2
X2
3
175
O.D.44.48
2
115
I.D.19.05
I.D12.7
82
70
O.D.22.2
120
O.D. 28.58
I.D. 22.2
O.D. 19.05
I.D.15.88
O.D.19.05
2
3
X2
(Unit : mm)
I.D. 9.52
I.D. 12.7
High Pressure Gas pipe
I.D38.1
I.D34.9
I.D28.58
2
I.D.19.05
I.D28.58
I.D22.2
I.D34.9
I.D38.1
471
517
125
3
3
I.D19.05
I.D15.88 O.D38.1 I.D41.3
O.D22.2
I.D.15.88
I.D.12.7
110
3
3
O.D15.88
O.D. 19.05
I.D. 9.52
I.D. 28.58
I.D. 12.7
I.D. 25.4
I.D34.9
I.D41.3
346
379
I.D.25.4 I.D.22.2
O.D.28.58
X2 3
100
I.D. 12.7
I.D. 28.58
25.4
I.D.I.D.
19.05
I.D.25.4
I.D.22.2
I.D.19.05 96
I.D.53.98
3
I.D. 25.4
I.D.I.D.
19.05
19.05
I.D. 28.58
O.D. 19.05
I.D. 9.52
O.D. 28.58
I.D. 22.2
2
3
I.D.I.D.
9.5228.58
I.D. 12.7
I.D. 12.7
O.D. 9.52
I.D. 6.35
I.D.22.2
I.D. 28.58
O.D. 19.05
I.D. 12.7
I.D. 34.9
I.D. 9.52
I.D. 28.58
I.D. 12.7
O.D. 28.58
I.D. 22.2
O.D. 9.52
I.D. 6.35
I.D. 15.88
I.D.44.48
I.D38.1 134
420
490
ARBLB23220
I.D22.2
19.05
I.D. 28.58 I.D.I.D.
19.05
I.D. 25.4
I.D. 34.9
I.D. 15.88
I.D.
I.D.9.52
12.7
I.D. 15.88
I.D.25.4
I.D25.4
I.D. 19.05
O.D. 28.58
I.D. 22.2
Liquid pipe
2
1
I.D. 19.05
I.D. 28.58
I.D. 28.58
I.D. 12.7
I.D. 15.88
I.D.
I.D. 9.52
19.05
I.D.28.58
12.7
I.D.
O.D. 19.05
I.D. 28.58
I.D. 9.52
I.D. 15.88
I.D. 9.52
O.D. 19.05
I.D. 19.05
I.D. 12.7I.D. 12.7
I.D. 34.9
O.D. 9.52
I.D. 6.35 I.D. 15.88
I.D. 12.7
O.D. 19.05
I.D. 15.88
I.D.44.48
I.D41.3
I.D38.1
I.D. 9.52
12.7
I.D.I.D.
19.05
I.D. 15.88I.D. 12.7
I.D. 28.58
I.D. 12.7
I.D. 15.88
I.D. 19.05
I.D. 22.2
I.D. 28.58
X2
I.D. 12.7
O.D. 19.05
I.D.I.D.
28.58
19.05 O.D.
O.D.34.9
25.4
15.88
I.D. 31.8
O.D. 28.58I.D.I.D.
22.2
Low Pressure Gas pipe
I.D.19.05
12.7
O.D.
O.D. 19.05
I.D. 34.9
I.D. 12.7
I.D. 15.88
• R410A / MULTI V III Heat recovery, MULTI V IV Heat recovery, MULTI V WATER IV Heat recovery
• R410A / MULTI V PLUS, MULTI V PLUS II, MULTI V III, MULTI V IV, MULTI V WATER IV
I.D. 9.52
O.D. 19.05I.D. 28.58
O.D. 19.05
I.D. 12.7
12.7
I.D. 19.05 I.D.I.D.
9.52
I.D. 15.88
I.D. 15.88
I.D. 19.05
I.D. 28.58
X 2 O.D. 19.05
I.D.I.D.
12.728.58I.D. 22.2
I.D. 19.05 O.D. 25.4
I.D. 31.8
I.D. 15.88
I.D. 25.4
I.D. 28.58 O.D. 34.9
I.D. 38.1
I.D. 31.8
O.D. 28.58 I.D. 22.2
I.D. 19.05 O.D. 25.4
12.7
I.D.I.D.
19.05
I.D. 19.05I.D. 12.7
I.D. 25.4
I.D. 15.88
I.D. 12.7
I.D. 15.88
I.D. 19.05
I.D.I.D.
25.428.58
X2
I.D. 15.88
I.D. 25.4
I.D.
28.58
O.D.22.2
19.05
I.D.
I.D. 19.05 O.D.I.D.19.05
12.7
I.D. 9.52
I.D. 19.05
I.D. 22.2
I.D.28.58
41.3 O.D. 34.9
I.D.
I.D. 34.9
I.D. 41.3I.D. 22.2
I.D. 31.8
O.D. 28.58
I.D. 34.9
I.D. 28.58 O.D. 34.9
I.D.19.05
31.8 I.D. 12.7
I.D. 25.4
I.D.
31.8 O.D. 25.4
O.D.O.D.
28.58
19.05
I.D. 22.2
I.D.I.D.
41.3
I.D. 38.1
34.9
I.D.I.D.
15.88
I.D. 41.3
I.D. 34.9
I.D19.05
O.D28.58
I.D. 31.8
I.D. 19.05
I.D. 15.88
I.D. 28.58
I.D. 19.05
I.D. 22.2
I.D. 12.7
I.D. 9.52
O.D. 12.7
I.D. 22.2
ARBLB14520 I.D. 38.1
O.D34.9
I.D41.3
I.D41.3
I.D38.1
I.D15.88
I.D. 15.88
I.D. 34.9
I.D. 31.8
41.3 I.D. 25.4
I.D. 38.1
I.D22.2
I.D34.9
ARBLB14521
O.D22.2
O.D22.2
I.D. 9.52
O.D. 12.7
I.D. 9.52
I.D. 9.52
I.D. 12.7
O.D. 12.7
I.D. 6.35
I.D. 34.9
I.D. 41.3
I.D. 34.9
I.D28.58
I.D28.58
I.D38.1
I.D. 9.52
I.D. 34.9 O.D.
28.58
O.D.
19.05O.D. 22.2
I.D. 12.7 I.D. 15.88
I.D. 15.88 I.D. 19.05
I.D. 31.8
O.D12.7
I.D34.9
I.D34.9
I.D. 6.35
I.D. 22.2
I.D. 15.88
X2
I.D9.52
I.D. 12.7
I.D. 22.2
9.52
I.D. 15.88 I.D.I.D.9.52
I.D. 28.58
I.D. 12.7 I.D. 9.52
I.D. 19.05
I.D. 12.7
I.D. 12.7 I.D. 6.35
I.D. 22.2
X2
I.D15.88
I.D19.05
I.D.
22.2 X 2
I.D.I.D.
19.05
I.D. 34.9 O.D. 28.58 I.D.
I.D.
25.4
15.88
O.D.28.58
22.2
O.D12.7
I.D. 28.58 I.D6.35
I.D.
I.D. 19.05
I.D.25.4
34.9 O.D.
I.D.28.58
31.8 O.D. 22.2 I.D. 19.05
I.D. 15.88 I.D. 15.88
I.D. 22.2
I.D. 28.58
I.D9.52
I.D.
12.7
I.D. 31.8
I.D. 19.05
I.D9.52
I.D9.52
O.D31.8
I.D. 6.35
I.D. 15.88
I.D12.7
I.D.
15.88
I.D. 19.05
I.D. 22.2 I.D. 12.7
I.D. 22.2
O.D12.7
O.D. 19.05
I.D. 12.7I.D. 19.05
I.D. 28.58
X2
I.D. 15.88
I.D. 25.4
O.D. 19.05
I.D. 12.7
I.D. 34.9 O.D. 28.58I.D.O.D.
15.88
I.D. 15.88
22.2
I.D. 31.8
I.D. 19.05
I.D. 22.2
I.D. 19.05
I.D. 19.05
I.D. 25.4I.D. 25.4
I.D. 28.58
I.D. 28.58
Piping Accessories
I.D28.58
I.D34.9
I.D15.88
I.D6.35
O.D12.7
O.D22.2
I.D31.8
9.529.52
I.D.
I.D.15.88
15.88 I.D.I.D.
I.D. 28.58
I.D. 28.58
I.D. I.D.
19.0519.05
I.D. 19.05
I.D. 28.58
I.D. 22.2
O.D. 19.05
I.D.12.7
12.7
I.D.
I.D.19.05
19.05
I.D.
12.7
I.D.I.D.
12.7
I.D12.7
I.D. 28.58I.D. 19.05
I.D. 28.58
I.D. 22.2
I.D. 25.4
I.D. 25.4
ARBLB07120
ARBLB07121
I.D19.05
I.D.I.D.
22.222.2
I.D. I.D.
25.425.4 I.D19.05
I.D15.88
I.D. 25.4
I.D. 28.58
I.D19.05
ARBLB07120
I.D. 22.2
I.D12.7
I.D31.8
I.D. 22.2
O.D. 19.05
I.D. 12.7
I.D. 9.52 I.D. 6.35
I.D. 6.35
I.D. 9.52
I.D6.35
I.D. 28.58
I.D. 28.58
I.D15.88
I.D12.7
I.D15.88
I.D. 9.52
I.D. 12.7
I.D. 12.7
I.D. 15.88
I.D. 19.05
I.D. 12.7
19.05
I.D.
I.D. 9.52
I.D. 6.35
I.D. 9.52 I.D. 6.35
I.D. 12.7 I.D. 12.7
I.D. 9.52
I.D. 6.35
I.D. 6.35
I.D. 9.52
I.D.
15.88
I.D. 15.88 I.D. 22.2
I.D. 6.35
I.D. 9.52
O.D. 19.05
I.D. 19.05
I.D. 19.05
I.D. 22.2
I.D. 9.52
O.D. 19.05 I.D. 12.7
I.D. 6.35
I.D. 9.52 I.D. 6.35
I.D. 12.7
I.D12.7
I.D. 28.58
I.D. 28.58
I.D. 22.2I.D. 22.2
I.D19.05
I.D28.58
I.D. 6.35
I.D. 19.05
I.D. 15.88
I.D. 6.35
I.D. 9.52
I.D. 12.7
I.D. 19.05
I.D. 9.52
I.D. 6.35
I.D. 15.88
I.D. 15.88
I.D. 6.35
I.D. 12.7
I.D. 12.7 I.D. 15.88
I.D. 6.35
I.D.
19.05
12.7
I.D.I.D.
9.52
I.D. 15.88
I.D. 19.05
I.D. 6.35
I.D9.52
O.D19.05
I.D25.4
I.D 22.2
I.D. 6.35
I.D. 6.35
I.D. 9.52
I.D. 9.52
I.D. 12.7
I.D. 15.88
12.7
I.D.I.D.
9.52
I.D12.7
I.D. 15.88
O.D19.05
I.D. 12.7
I.D. 9.52 I.D. 6.35
I.D. 12.7
I.D. 19.05
I.D. 15.88
I.D. 9.52
I.D. 22.2
I.D. 15.88
I.D9.52
I.D12.7
I.D25.4
I.D12.7
I.D. 19.05
I.D. 6.35
I.D. 19.05
I.D. 15.88
O.D.
28.58
I.D. 9.52
I.D. 15.88
I.D9.52
I.D. 15.88I.D. 12.7 I.D6.35
I.D. 25.4 I.D.
O.D.22.2
22.2
I.D. 22.2 I.D. 19.05 O.D. 28.58
I.D. 6.35
I.D. 25.4
I.D. 9.52 I.D. 12.7
ARBLB03320
I.D 22.2
I.D 22.2
I.D15.88
I.D6.35
O.D19.05
I.D25.4
O.D19.05
I.D19.05
I.D. 22.2
ARBLB03320
I.D19.05
I.D12.7
I.D15.88
I.D. 15.88
I.D.I.D.15.88
9.52 I.D. 6.35
I.D. 15.88
I.D. 6.35
I.D. 9.52
I.D. 19.05
I.D. 9.52
I.D. 15.88
I.D. 22.2
I.D. 9.52
I.D. 9.52
I.D. 22.2 I.D. 19.05
ARBLB03320
I.D12.7
I.D. 12.7
I.D. 12.7
15.88
I.D.
I.D. 9.52 I.D. 6.35
I.D. 9.52
I.D.
I.D. 12.7 12.7
I.D. 12.7
I.D. 6.35
I.D.
I.D.9.52
9.52
I.D. 9.52
I.D. 12.7I.D. 9.52
I.D. 15.88
I.D. 12.7
I.D. 15.88
I.D. 6.35
I.D. 12.7
I.D6.35
I.D. 19.05
I.D. 15.88
I.D. 12.7
I.D. 22.2
I.D. 15.88
I.D. 22.2 I.D. 19.05
I.D6.35
I.D. 12.7
I.D. 15.88
I.D. 12.7
I.D9.52
I.D. 6.35
I.D. 15.88
I.D. 9.52
I.D12.7
I.D. 15.88
I.D. 12.7
I.D. 15.88
I.D. 9.52
I.D. 6.35
I.D. 9.52
I.D. 6.35
I.D. 12.7I.D. 9.52
I.D. 12.7
I.D. 15.88
I.D12.7
I.D19.05
I.D. 15.88
I.D. 9.52
I.D. 6.35
I.D. 12.7
I.D. 9.52
I.D. 12.7
I.D. 12.7
I.D. 12.7
I.DI.D.
6.35 9.52
I.D. 9.52
I.D. 12.7
I.D. 12.7
I.D. 9.52
I.D. 6.35
I.D. 6.35
I.D. 12.7
I.D. 15.88
I.D. 12.7I.D. 19.05
O.D9.52
O.D15.88
I.D9.52
I.D. 15.88
I.D. 12.7
I.D6.35
I.D6.35
I.D. 9.52
I.D12.7
I.D. 15.88
I.D. 19.05
I.D. 12.7 I.D9.52
I.D. 15.88
I.D. 19.05
I.D. 15.88
ARBLB01620
I.D15.88
I.D12.7
I.D. 12.7
I.D. 9.52
I.D. 12.7
I.D. 15.88
I.D15.88
I.D15.88
I.D12.7
High Pressure Gas pipe
I.D. 6.35
I.D. 15.88
I.D. 19.05
3
I.D9.52
O.D12.7
I.D6.35
2
120
O.D34.9
I.D38.1
I.D41.3
3
130
90
3
110
3
O.D15.88
I.D12.7
I.D22.2
O.D28.58
I.D19.05
2
70
120
83
The Total HVAC and
Energy Solution Provider
Ever since manufacturing Korea’s first homegrown air
conditioner in 1968, LG has remained at the forefront of air
conditioning innovation. For eight of the last 10 years, LG
has been the world’s top selling manufacturer of residential
air conditioning solutions. And in 2008, LG became the first
company to sell a cumulative total of more than 100 million
air conditioners.
Building on its success and technological leadership in
the residential air conditioning sector, LG has moved into
system air conditioning as well. The company’s range of
84
high-performance system air conditioning products provides
effective temperature control to large-scale buildings and
facilities. Over time, LG has evolved into the total HVAC and
energy solution provider, investing in new technologies and
adding chillers, VRF systems, and building management
systems (BMS) into its comprehensive product portfolio.
Along with a wide range of innovative solutions, LG delivers
unrivalled customer service. The company produces topnotch air conditioning professionals at its SAC academies,
of which there are more than 100 worldwide. These centers
of excellence provide detailed product workshops and
training programs that offer invaluable hands-onexperience.
LG also provides useful tools for HVAC system engineers
and installers, including its timesaving LG Air Conditioner
Technical Solution (LATS) software.
Additionally, LG operates several state-of-the-art R&D
facilities all across the planet. One such facility is the
Energy Lab, a purpose-built R&D and testing center in
northern France. Helping to keep the company ahead of the
competition, the scientists and engineers at theEnergy Lab
study the effects of different environmental conditions on
LG’s products. This in-depth research and analysis enables
LG to tailor its solutions to the specific environmental
demands of each individual market.
With 10 manufacturing plants throughout the world, LG
produces in excess of 17 million reliable compressors and
16 million first-class HVAC solutions per year. Combining
the best technologies with the best ideas, LG’s high quality
products are now enjoyed by consumers in over 100 countries.
85
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement