SCAN 3-channel radio flush receiver ROP-04 the technical data Co-operation with EXTA FREE transmitters ROP-04 receiver is designed to carry out simple control functions in LED diode systems supplied with 10 ÷ 14 V DC. In connection with EXTA FREE system transmitters, it enables the realisation of the switch on/switch off function, the monostable mode, the bistable and time modes. ROP-04 has 3 independently controlled outputs realised on MOSFET transistors. The outputs are designed for a direct connection of LED diode products. Characteristic features: • cooperation with wireless EXTA FREE system transmitters, • independent control of up to three receivers in the following modes: switch on/switch off, monostable, bistable, time, • 3 MOSFET type transistor outputs with a maximum capacity of 2,5 A / output, • possibility of a direct connection of 10 ÷ 14 V DC power supply LED products to the receiver’s outputs, • wide operation range (up to 230 m outdoors), • small dimensions - suitable for mounting in a typical Ø60 junction box, • low power consumption in the standby mode (0,22 W) - the receiver is used to a continuous operation. Mounting indoor only Mounting in a Ø60 junction box 10 ÷ 14 V DC 3-channel radio flush receiver ROP-04 Zamel Sp. z o.o. PL 43-200 Pszczyna, ul. Zielona 27, Poland tel: +48 32 449 15 00, fax: +48 32 449 15 02 e-mail: [email protected], www.ledix.pl CET Lighting Sp. z o.o. declares that the equipment complies with the principal requirements and other applicable rules of the RTTE Directive. The symbol means selective collecting of electrical and electronic equipment. It is forbidden to put the used equipment together with other waste. Declaration of Conformity is on www.ledix.pl ROP-04 ENG Ver. 01 www.ledix.pl 10÷14 V DC / 0,22 W; IP20 weight: 25 g DESCRIPTION APPEARANCE ROP-04 receiver is designed to carry out simple control functions in lighting installations equipped with LED diodes. This device in connection with any wireless EXTA FREE (www.extafree.pl) system transmitter enables the realisation of the switch on/switch off function, the monostable mode, the bistable and time mode independently for every channel. ROP-04 is designed to a direct cooperation with any 10 ÷ 14 V power supply LED diode lighting. The receiver has three MOSFET type transistor outputs with a maximum capacity of 2,5 A. Small dimensions of the casing allow for a direct mounting of the receiver in the Ø60 mm junction box. The product is characterised by low power consumption. Features of the controller: •cooperation with wireless EXTA FREE system transmitters, •realisation of the control function in 10 ÷ 14 V power supply LED diode lighting installations, •3 MOSFET type transistor outputs - maximum capacity of 2,5 A / output, •the possibility of independent control of three circuits, •multiplicity of operation modes: switch on / switch off, monostable, bistable, time, •wide operation range (up to 230 m outdoors), •a possibility to increase the operation range by using RTN-01 retransmitter, •low power consumption in the standby mode (0,22 W) - a device designed for continuous operation. TECHNICAL DATA Nominal supply voltage: Nominal power consumption: Number of channels: Maximum current in the channel: Modes: Control: Radio transmission: Transmission method: Coding: Maximum number of transmitters: Range: Time adjustment: Ambient temperature range: Mounting: Casing protection degree: Protection class: Dimensions: Weight: Reference standard: Optic signalling of the receiver’s operation Channel 1,2 ,3 terminals Programming button Power supply terminals (+, -) DIAGRAM Exemplary LEDIX series fittings ZNP, ZNN or ZNM series power supply in 14 V DC version 10 ÷ 14 V DC 0,22 W 3 x MOSFET 2,5 A Switch on/switch off, Monostable, Bistable, Time EXTA FREE system transmitters 868,32 MHz One-way without confirmation Yes – transmission with addressing 32 Up to 230 m in the open area 1 s ÷ 18 h -10 ÷ +55 oC In a Ø60 junction box IP20 III 47,5 x 47,5 x 20 mm 25 g PN-EN 60669; PN-EN 60950; PN-EN 61000 230 V AC 14 V DC MAXIMUM CURRENT CAPACITY: Up to 25 W for LED diode products supplied with 10 V Up to 30 W for LED diode products supplied with 12 V Up to 35 W for LED diode products supplied with 14 V MOUNTING CAUTION ! The device is designed for single-phase installation and must be installed in accordance with standards valid in a particular country. Installation, connection and control should be carried out by a qualified electrician staff, who act in accordance with the service manual and the device functions. 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch- disconnector combined to the proper circuit. 2.Check if there is no voltage on connection cables by means of a special measure equipment. 3.Connect the power supply to 230 V AC. 4.Connect the output cables with appropriate receiver’s cables in accordance with the connection diagram. 5.Mount the controller in the Ø60 junction box. 6.Switch on the power supply from the mains. 7.Add selected transmitters to the receiver (description in the TRANSMITTERS’ PROGRAMMING section) and check if they work properly. TIME PROGRAMMING FOR A SELECTED CHANNEL 1s 2s ns Press PROG push-button of ROP-04 device and then release it. LED red diode switches off and then switches on (the signal pulsates). Every LED diode pulse equals 1 second. OPERATION The device can operate in five modes for every channel: MONOSTABLE the relay operates only while pressing transmitter’s push-button. After the adjusted time is finished (the number of LED red diode flashes) press PROG push-button and then release it - TIME IS ADDED BISTABLE (one push-button) the device changes the relay status cyclically always after pressing the same push-button. Maximum time is 18 hours hours for every channel. SWITCH ON the device switches on after pressing the push-button. APPLICATION SWITCH OFF the device switches off after pressing the push-button. TIME the device switches off according to the adjusted time (tp), but it may be switched off before the adjusted time finishes. Default settings - 15 seconds. CAUTION! The adjusted time can not be deleted. Wall lamps and standard LEDIX series LED fittings are connected to the ROP-04 receiver. 4-channel button radio transmitter RNK-04 and a portable remote control P-257/4 cooperate with the receiver. The wall lamps are switched on in time mode (staircase function) and LEDIX fittings in the switch on / switch of mode. 200 200 250 200 200 250 180 180 180 200 180 180 250 P-260 RTI-01 RXM-01 RCR-01 RTN-01 RNL-01 RNP-02 RNP-01 P-257/4 RNM-10 P-257/2 P-256/8 RNK-04 RNK-02 ROP-04 Symbol OPERATION TABLE - CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range according to: bricks: from 10 to 40 %, wood and plaster: from 5 to 20 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100%, glass: from 10 to 20 %. Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have also a negative influence on the range. RADIO TRANSMITTERS PROGRAMMING BISTABLE mode (for a selected channel): An exemplary programming procedure with the use of P-257/2 remote control. The procedure for the rest of radio EXTA FREE transmitters is analogous. CAUTION: Every transmitter can cooperate with ROP-04 in a different mode, depending on how they were added to the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode. Transmitters and time programming is done in a sequence: Wait for about 5 sec. Press PROG push-button of ROP-04 device Wait for about 5 sec. Transmitters’ programming for channel 1 Wait for about 5 sec. Time programming for channel 1 Wait for about 5 sec. Transmitters’ programming for channel 2 SWITCH ON/SWITCH OFF mode (two push-buttons for a selected channel): Press PROG push-button of ROP-04 device for a longer time until LED red diode switches on (constant signal). Next release PROG push-button Time programming for channel 3 In order to facilitate the radio transmitters’ programming, every time when we enter the programming mode of a selected channel (or time adjustment in time mode) the load connected to that channel is switched on. The channel switch on is connected with LED red diode lighting (the signal is constant). MONOSTABLE mode (for a selected channel): Press the transmitter’s push-button for a longer time. Press PROG push-button of ROP-04 device for a longer time until LED red diode switches on (constant signal). Next release PROG pushbutton Press the transmitter’s Press and release the same push-button for a longer transmitter’s push-button. LED red diode switches on time. LED red diode (the signal pulsates) and switches on (first signal pulsates, next the signal is next it switches off - THE TRANSMITTER IS ADDED constant) Transmitters’ programming for channel 3 Wait for about 5 sec. Time programming for channel 2 Press PROG push-button of ROP-04 device for a longer time until LED red diode switches on (constant signal). Next release PROG push-button Press the same transmitRelease the transmitter’s ter’s push-button and push-button. LED release it. LED red red diode switches diode switches on (the on (first the signal signal pulsates) and pulsates, next the next it switches off - THE signal is constant). TRANSMITTER IS ADDED. Press and release the first transmitter’s push-button. LED red diode switches on (first the signal pulsates, next the signal is constant) TIME mode (one push-button for a selected channel): Press PROG push-button of Press and release ROP-04 device for a longer time transmitter’s push-button. until LED red diode switches on LED red diode switches on (constant signal). Next release (first the signal pulsates, PROG push-button next the signal is constant) Press and release the second transmitter’s push-button. LED red diode switches on (the signal pulsates) and next it switches off - THE TRANSMITTER IS ADDED Press and release the same transmitter’s push-button. LED red diode switches on (the signal pulsates) and next it switches off - THE TRANSMITTER IS ADDED RADIO TRANSMITTERS DELETION Press PROG push-button of ROP-04 device for a longer time. After 5 seconds LED red diode switches on (the signal pulsates) and then it switches off. Release the push-button in ROP-04 - MEMORY IS DELETED.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project