Fluke Corporation Fluke 190-502 Scope Meter with software and

Fluke Corporation Fluke 190-502 Scope Meter with software and
20 years of ScopeMeter® Test Tool Innovation
Introducing the complete
190 Series II
190 Series II ScopeMeter
Oscilloscopes—the first highperformance scopes built for
harsh industrial environments
Technical Data
New
500 MHz
Introducing the first high-performance portable
oscilloscopes with 2 or 4 independently insulated
input channels, an IP51 dust- and dripwater proof
rating and a CAT III 1000 V/CAT IV 600 V safety rating.
Choose from 500 MHz, 200 MHz, 100 MHz or
60 MHz bandwidth models. Now plant maintenance
engineers can take a 2- or 4-channel scope into the
harsh world of industrial electronics.
190 Series II—a new generation of
Fluke ScopeMeter Oscilloscopes
QU
AL
IF
90
01
EM
ST
www.
®
RT
Shop for Fluke products online at:
ANAGEMENT S
YM
Y
IT
CE
The 190 Series II include these capabilities:
•Up to four independent floating isolated inputs, up to 1000 V
•Up to 5 GS/s real time sampling (Depending on model and channels used)
•Deep memory: 10,000 points per trace waveform capture (scope mode)
•CAT III 1000 V/CAT IV 600 V safety rated instrument for industrial
environments
•Up to seven hours of battery operation using BP291
•Isolated USB host port for direct data storage to a USB memory device;
USB device port for easy PC communication
•Easy access battery door for quick battery swaps in the field
•Compact and only 2.2 kg (4.8 lb)
•Security slot: lock down oscilloscope with Kensington® lock while
unattended
•IP 51 rating, dust- and drip-proof
•Connect-and-View™ triggering for intelligent, automatic triggering on fast,
slow and even complex signals
•Frequency Spectrum using FFT-analysis
•Automatic capture and REPLAY of 100 screens
•ScopeRecord™ Roll mode gives 30,000 points per input channel for low
frequency signal analysis
•TrendPlot™ paperless recorder mode with deep memory for long-term
automatic measurements
•5,000 count DMM included in the 2-channel models
IE D
TO MEET
IS
O
MyFlukeStore.com
1.877.766.5412
Oscilloscope modes
190-062
190-102
190-202
190-502
190-104
190-204
Vertical deflection
Number of channels
Bandwidth
Rise time
Number of scope inputs
Channel architecture
Input coupling
Input sensitivity
Bandwidth limiter
Normal/invert/variable
2
2
2
2
60 MHz
100 MHz
200 MHz
500 MHz
5.8 ns
3.5 ns
1.7 ns
0.7 ns
2 input channels plus external trigger
All inputs fully insulated from each other and from ground
Inputs may be activated in any combination
AC or DC, with ground level indicator
2 mV/div to 100 V/div, plus variable attenuation
User selectable: 20 kHz, 20 MHz or full bandwidth
On each input channel, switched separately
4
4
100 MHz
200 MHz
3.5 ns
1.7 ns
4 input channels
Input voltage
Vertical resolution
Accuracy
Input impedance
CAT III 1000 V/CAT IV 600 V rated, see General Specifications for further details
8 bit
± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div
1 MΩ ± 1 % // 14 pF ± 2 pF
Horizontal
Maximum real-time sample
rate (sampled simultaneously)
625 MS/s for
each channel
Record length
Time base range
Up to 10,000 samples per channel
10 ns/div
5 ns/div
2 ns/div
1 ns/div.
5 ns/div
to 4 s/div
to 4 s/div
to 4 s/div
to 4 s/div.
to 4 s/div
Time base in a 1-2-4-sequence
Slower time/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’)
10,000 samples per channel in scope mode;
30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’)
± (0.01 % of reading + 1 pixel)
8 ns peak detect on each channel
(using real time sampling and data compression, at any timebase setting)
Maximum record length
Timing accuracy
Glitch capture
1.25 GS/s for
each channel
2.5 GS/s (2ch)
5 GS/s (single
channel) or 2.5
GS/s (on 2ch)
1.25 GS/s for
each channel
2.5 GS/s (2ch)
1.25 GS/s (4ch)
2 ns/div
to 4 s/div
Display and acquisition
Display
Display modes
Visible screen width
Digital persistence modes
Waveform mathematics
Acquisition modes
153 mm (6 in) full-color LCD with LED backlight
Any combination of channels; average on/off; replay
12 divisions horizontally in scope mode
off/short/medium/long/infinite and envelope mode
One mathematical operation on any 2 input channels: add/subtract/multiply; X-Y-mode
Frequency Spectrum using FFT analysis
Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture,
waveform compare with automatic “Pass/Fail testing”; Replay
Trigger and delay
Source
Modes
Connect-and-View™
Video triggering (on ch. A)
High-res, non-interlaced video
Pulse width triggering
(on channel A)
Time delay
Dual slope triggering
N-cycle triggering
2 Fluke Corporation
Input A, B or External (via meter input)
Input A, B, C or D
Automatic Connect-and-View™, free run, single shot, edge, delay, dual slope,
video, video line, selectable pulsewidth (channel A only), N-cycle
Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts
triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals
like motor drive and control signals. Can be switched off if preferred.
NTSC, PAL, PAL+, SECAM; Includes field 1, field 2 and line select
Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz
Pulse width qualified by time
Allows for triggering <t, >t, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns
1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay
Triggers on both rising and falling edges alike
Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99
ScopeMeter 190 Series II
Shop for Fluke
products online at:
www.
MyFlukeStore.com
1.877.766.5412
Automatic capture of 100 screens
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is
seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on
glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events
Replay
Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual
control. Each screen has date and time-stamp.
Replay storage
Two sets of 100 screens each can be saved internally for later recall and analysis.
Direct storage of additional sets on external flash memory drive through USB host port.
FFT—frequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
Window
Automatic, Hamming, Hanning or None
Automatic window
Digitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant
Vertical scale
Linear/Logarithmic (in volts or amps)
Frequency axis
Frequency range automatically set as a function of timebase range of oscilloscope
Waveform compare and pass/fail testing
Waveform Compare
Pass/Fail Testing
Provides storage and display of a reference waveform for visual comparison with newly acquired
waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope
In waveform compare mode, the oscilloscope can be set up to store only matching (“Pass”) or only
non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis
Automatic scope measurements
V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (in Hz), risetime (using cursors), falltime (using
cursors), Power Factor (PF), Watts, VA, VA reactive, phase (between any 2 inputs), pulsewidth (pos./neg.), dutycycle (pos./neg.), temperature °C,
temperature °F (not for Japan), dBV, dBm into 50 I and 600 I, VPWM ac and VPWM(ac+dc) for measurement on pulsewidth modulated motordrives
and frequency inverters, V/Hz ration (190-xx2 only)
Advanced power and motor drive
V/Hz ratio (190-x02 only), Power Factor (PF), Watts, VA, VA reactive, VPWMac and VPWM (ac+dc) for
functions
measurement on pulsewidth modulated motordrives and frequency inverters
Advanced functions
mA*s (current-over-time, between cursors);
V*s (voltage over time, between cursors);
W*s (energy, between cursors)
Cursor measurements
Source
Dual horizontal lines
Dual vertical lines
Single vertical line
ZOOM
On any input waveform or on mathematical resultant waveform (excl. X-Y-mode)
Voltage at cursor 1 and at cursor 2, voltage between cursors
Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers,
falltime with markers; Vrms between cursors, Watts between cursors
Min-Max and Average voltage at cursor position; frequency and rms-value of individual frequency
component in the FFT Resultant
Ranges from full record overview to zoom in up to sample level, at any record length
Shop for Fluke products online at:
www.
MyFlukeStore.com
Fluke Corporation 3
1.877.766.5412
ScopeMeter 190 Series II
Meter modes
190-062
190-102
190-202
190-502
190-104
Meter inputs
Via 4 mm banana inputs, fully isolated from
scope inputs and scope ground
Number of readings
Maximum resolution
Input impedance
Advanced meter functions
One at a time
Up to 4 simultaneously
5,000 counts
999 counts
1 MΩ ± 1 % // 14 pF ± 2 pF
Auto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording
The specified accuracy is valid over the temperature range 18 °C to 28 °C
Add 10 % of specified accuracy for each degree C below 18 °C or above 28 °C
190-204
Via BNC scope inputs
Voltage
V dc accuracy
V ac true rms accuracy
15 Hz to 60 Hz:
60 Hz to 1 kHz:
60 Hz to 20 kHz:
V ac+dc true rms accuracy
15 Hz to 60 Hz:
60 Hz to 1 kHz:
60 Hz to 20 kHz:
Voltmeter ranges
± (0.5 % + 5 counts)
± (1.5 % + 5 counts)
± (1 % + 10 counts)
± (2.5 % + 15 counts)
± (1.5 % + 10 counts)
± (2.5 % + 15 counts)
± (1 % + 10 counts)
± (2.5 % + 15 counts)
± (1.5 % + 10 counts)
± (2.5 % + 15 counts)
500 mV, 5 V, 50 V, 500 V, 1,000 V
Resistance
Ranges
Accuracy
500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
± (0.6 % + 5 counts)
—
—
Beeper on < 50 Ω (± 30 Ω)
Up to 2.8 V
A dc, A ac, A ac+dc using an optional current clamp or shunt
Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A
With optional accessories. Scale factors 1 °C/mV or 1 °F/mV
—
—
Other meter functions
Continuity
Diode test
Current (A)
Temperature
4 Fluke Corporation
ScopeMeter 190 Series II
Shop for Fluke
products online at:
www.
MyFlukeStore.com
1.877.766.5412
Recorder modes
190-062
ScopeRecord™
190-102
190-202
190-502
190-104
190-204
Roll Mode
Dual or multiple input waveform storage mode, using deep memory
Source and display
Input A, Input B, Dual.
All channels sampled simultaneously.
Bandwidth
Memory depth
Min/max values
Recording modes
Stop-on-trigger
Horizontal scale
Zoom
Memory
Any combination of inputs,
up to 4 channels. All channels
sampled simultaneously.
20 MHz or 20 kHz, user selectable
30,000 data points, each holding min/max pair of information
Min/max values are created at samples that are measured at high sample rate
ensuring capture and display of glitches
Single sweep, continuous roll,
Single sweep, continuous roll,
Start-on-Trigger (through external),
Start-on-Trigger (through any
Stop-on-Trigger (through external)
channel), Stop-on-Trigger (through
any channel)
ScopeRecord mode can be stopped by an individual trigger event, or by an interruption
of a repetitive trigger signal, through any input channel (through External on 190-XX2 Series)
Time from start, time of day
Ranges from full record overview to zoom in up to sample level, at any record length
Two multiple input ScopeRecord waveforms can be saved internally for later recall and analysis
Direct storage on external flash memory drive through USB host port
ScopeRecord™ Roll mode sample rate and recording timespan
Time base range
Recorded timespan
Time/division in ‘view all’ mode
Glitch capture
Sample rate
Resolution
5 ms/div ~ 2 min/div
6 sec ~ 48 hr
0.5 s/div ~ 4 h/div
8 ns
125 MS/s
200 μsec ~ 4.8 sec
Trendplot™ Recording
Multiple channel electronic paperless recorder. Graphically plots, displays and stores results of up to four automatic scope measurements or a
DMM-reading over time.
Source and display
Any combination of scope measurements, made on any of the input channels, or DMM reading
(2-channel instruments)
Memory depth
18,000 points (sets) per measurement. Each recorded sample point contains a minimum, a maximum and an
average value, plus a date- and timestamp.
Ranges
Normal view: 5 s/div to 30 min/div
In view-all mode: 5 min/div to 48 hr/div (overview of total record)
Recorded time span
Up to 22 days, with a resolution of 102 seconds
Recording mode
Continuous recording, starting at 5 s/div with automatic record compression
Measurement speed
3 automatic measurements per second or more
Horizontal scale
Time from start, time of day
Zoom
Up to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail
Memory
Two multiple input TrendPlot records can be saved internally for later recall and analysis
Direct storage on external flash memory drive through USB host port
Cursor measurements—all recorder modes
Source
Dual vertical lines
Any waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot)
Cursors may be used to identify Min, Max or Average value of any datapoint in a record,
with time between cursors, time from start or absolute time.
Shop for Fluke products online at:
www.
MyFlukeStore.com
Fluke Corporation 5
1.877.766.5412
ScopeMeter 190 Series II
General Specifications
190-062
190-102
190-202
190-502
190-104
190-204
Input voltage range
Rated maximum floating voltage
Probe input voltage VPS410
Probe input voltage VPS510
Maximum BNC input voltage
Maximum voltage
on meter input
CAT III 1000 V/CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level)
CAT III 1000 V/CAT IV 600 V (Maximum voltage between 10:1 probe tip and reference lead)
CAT III 300 V (Maximum voltage between 10:1 probe tip and reference lead)
CAT IV 300 V (maximum voltage on BNC input directly)
CAT III 1000 V/CAT IV 600 V
—
(safety designed banana input connectors)
Memory save and recall
Memory locations (internal)
15 waveform memory locations
Two recording memories
External data storage
Screencopies
Volatility
Real-time clock
30 waveform memories plus 10 recording memories plus 9 screen copy memories (190-XX, 2 channel
models); 15 waveforms memories plus 2 recording memories plus 1 screen copy memory (190-XX, 4 channel
models)
Stores Scope-trace waveform data (2 or 4 traces each) plus screen-copy plus corresponding setup
Each may contain:
• a 100 Screen Replay sequence, or
• a ScopeRecord Roll-mode recording (2 or 4 traces), or
• a TrendPlot recording of up to 4 measurements
• On PC, using FlukeView™ Software, or
• Direct storage on external flash memory drive (maximum 2 GB) through USB host port
• On PC, using FlukeView™ Software, or
• Internally (in instrument) which can be copied on to external flash memory drive as .BMP-file,
through USB host port
Measurement data is initially stored in RAM, which is maintained by the main battery with a 30 seconds
back-up when battery is exchanged
When storing data, this is written in non-volatile flash-ROM
Provides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and
for TrendPlot recordings
Case
Design
Drip and dust proof
Shock and vibration
Display size
Resolution
Contrast and brightness
Rugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard
Kensington lock supported to lock down instrument when left unattended
IP 51 according to IEC529
Shock 30 g, vibration (sinusoidal) 3 g according to MIL-PRF-28800F Class 2
127 mm x 88 mm (153 mm/6.0 in diagonal) LCD
320 x 240 pixels
User adjustable, temperature compensated
Brightness
200 cd/m2 typ. using power adapter, 90 cd/m2 typical using battery power
Mechanical data
Size
Weight (including battery)
265 mm x 190 mm x 70 mm (10.4 in x 7.5 in x 2.8 in)
2.1 kg (4.6 lb)
2.2 kg (4.8 lb)
Power
Line power
Battery power
Battery type (incl.) and capacity
[+opt. battery]
Battery charge indicator
Battery operating time
(with backlight low)
Battery charging time
Battery power saving functions
Mains adapter/battery charger BC190 included, version depending of country
Re-chargeable double capacity Li-Ion battery (included). Battery swappable through
easily accessible battery door at the rear of the instrument
BP290; 2400 mAh
BP291; 4800 mAh
[BP291 (4800 mAh) optional]
Battery has built-in status indicator for use with external charger,
next to battery status indicator on instrument screen
Up to four hours using BP290 (included),
Up to seven hours using BP291 (included)
Up to eight hours using BP291 (optional)
2½ hours using BP290; 5 hours using BP291
Five hours BP291
Auto ‘power down’ with adjustable power down time; Auto ‘Display off’ with adjustable power down time;
On-screen battery power indicator
Safety
Compliance
6 Fluke Corporation
EN61010-1-2001, Pollution Degree 2;
CAN/CSA C22.2, No. 61010-1-04, with approval; UL61010B; ANSI/ISA-82.02.01
ScopeMeter 190 Series II
Shop for Fluke
products online at:
www.
MyFlukeStore.com
1.877.766.5412
Environmental
Operating temperature
Storage temperature
Humidity
Maximum operating altitude
Maximum storage altitude
Electro-MagneticCompatibility (EMC)
Interfaces
Probe calibration output
Warranty
190-062
190-102
190-202
190-502
190-104
190-204
0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery
-20 °C ~ +60 °C
+10 °C ~ +30 °C: 95 % RH non-condensing;
+30 °C ~ +40 °C: 75 % RH non-condensing;
+40 °C ~ +50 °C: 45 % RH non-condensing
Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V;
up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
12 km (40,000 ft)
EN 61326 (2005-12) for emission and immunity
Two USB-ports provided. Ports are fully insulated from instrument’s floating measurement circuitry USB-host
port directly connects to external flash memory drive (up to 2 GB) for storage of waveform data, complete
datasets in which data and setup information is included, instrument settings and screen copies
A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under
PC-control
Dedicated probe-cal output with reference contact provided,
fully insulated from any measurement input channel
Three years (parts and labor) on main instrument, one year on accessories
Included accessories
Battery charger/mains adapter
Li-Ion battery pack
Voltage probe sets. Each set
includes ground lead, hook
clip, ground spring and probe
tip insulation sleeve.
Test leads
Voltage Probes
Other
BC190
BP290 (2400 mAh)
VPS410 (one red, one blue)
BP291 (4800 mAh)
VPS410 (one red, one grey, one
blue, one green)
TL175 (one red, one black) with test pins
(N/A)
VPS410-x: each set includes: Ground lead, hook clip, ground spring and probe tip insulation sleeve.
VPS510-x: each set includes: Ground lead, hook clip, ground spring, probe tip insulation sleeve
and BNC-to probe tip adapter.
Li-Ion battery (BP290 or BP291, see above); Battery charger (BC190); Hangstrap; Handstrip
(user selectable for left- or right hand use); Multi language users manuals on CD-ROM;
FlukeView® demo package (with restricted functionality); USB interface cable for PC connectivity.
Shop for Fluke products online at:
www.
MyFlukeStore.com
Fluke Corporation 7
1.877.766.5412
ScopeMeter 190 Series II
Ordering information
Models
Fluke 190-502 Color ScopeMeter, 500 MHz, 2 channels plus DMM/Ext.input
Fluke 190-502/S Color ScopeMeter, 500 MHz, 2 channels plus DMM/Ext.input,
with SCC-290 kit included
Fluke 190-204 Color ScopeMeter, 200 MHz, 4 channels
Fluke 190-204/S Color ScopeMeter, 200 MHz, 4 channels, with SCC-290 kit
included
Fluke 190-104 Color ScopeMeter, 100 MHz, 4 channels
Fluke 190-104/S Color ScopeMeter, 100 MHz, 4 channels, with SCC-290 kit
included
Fluke 190-202 Color ScopeMeter, 200 MHz, 2 channels plus DMM/Ext.input
Fluke 190-202/S Color ScopeMeter, 200 MHz, 2 channels plus DMM/Ext.input,
with SCC-290 kit included
Fluke 190-102 Color ScopeMeter, 100 MHz, 2 channels plus DMM/Ext.input
Fluke 190-102/S Color ScopeMeter, 100 MHz, 2 channels plus DMM/Ext.input,
with SCC-290 kit included
Fluke 190-062 Color ScopeMeter, 60 MHz, 2 channels plus DMM/Ext.input
Fluke 190-062/SColor ScopeMeter, 60 MHz, 2 channels plus DMM/Ext.input,
with SCC-290 kit included
Accessories
BC190 BP290 BP291 EBC290 HH290 VPS510-R VPS510-G VPS510-B VPS510-V VPS410-R VPS410-G VPS410-B VPS410-V VPS420-R SW90W C290 SCC290 TL175 TRM50 AS400 RS400 RS500 Mains adapter/battery charger
Li-ion battery pack, 2400 mAh
Li-ion battery pack, 4800 mAh
External battery charger for BP290 and BP291 (uses BC190
mains adapter)
Hanging Hook for 190 Series II instruments
Electronic Voltage Probe set, 10:1, 500 MHz, one set red
Electronic Voltage Probe set, 10:1, 500 MHz, one set grey
Electronic Voltage Probe set, 10:1, 500 MHz, one set blue
Electronic Voltage Probe set, 10:1, 500 MHz, one set green
Industrial Voltage Probe set, 10:1, one set red
Industrial Voltage Probe set, 10:1, one set grey
Industrial Voltage Probe set, 10:1, one set blue
Industrial Voltage Probe set, 10:1, one set green
High working voltage ruggedized probe set, 100:1, 150 MHz
(bicolored, red/black)
FlukeView ScopeMeter Software package (full version)
Hard shell protective carrying case for 190 Series II
FlukeView ScopeMeter Software package (full version)
and C290 Carrying Case kit for 190-series II
TwistGuard™ safety designed Test Leads set (1 red, 1 black)
BNC Feedthrough 50 I terminator (set of 2 pieces, black)
Probe Accessory Extension Set for VPS400-series probes
Probe Accessory Replacement Set for VPS400-series probes
Probe Accessory Replacement Set for VPS500-series probes
Fluke. The Most Trusted Tools
in the World.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2012 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 8/2012 3801685C_EN
Pub_ID: 11781-eng
Modification of this document is not permitted
without written permission from Fluke Corporation.
8 Fluke Corporation
Series II
Shop for Fluke ScopeMeter
products190online
at:
www.
MyFlukeStore.com
1.877.766.5412
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising