SmartClass™ Fiber FBP-HD4i/HD4iP and OLP

SmartClass™ Fiber FBP-HD4i/HD4iP and OLP
SmartClassTM Fiber FBP-HD4i/HD4iP and OLP-82/82P
Inspect, test, certify, and save with one device
QUICK START GUIDE
22002195
REV 0
REV 0
Notice
Every effort was made to ensure that the information in this document was accurate at the time
of printing. However, information is subject to change without notice, and JDSU reserves the
right to provide an addendum to this document with information not available at the time that
this document was created.
Copyright
© Copyright 2012 JDSU, LLC. All rights reserved. JDSU, Enabling Broadband and Optical
Innovation, and its logo are trademarks of JDSU, LLC. All other trademarks and registered
trademarks are the property of their respective owners. No part of this guide may be reproduced
or transmitted electronically or otherwise without written permission of the publisher.
Trademarks
2
JDSU is a trademark of JDSU in the United States and other countries.
FCC Information
Electronic test equipment is exempt from Part 15 compliance (FCC) in the United States.
European Union
Electronic test equipment is subject to the EMC Directive in the European Union. The EN61326
standard prescribes both emission and immunity requirements for laboratory, measurement,
and control equipment. This unit has been tested and found to comply with the limits for a
Class A digital device.
Independent
Laboratory Testing
This unit has undergone extensive testing according to the European Union Directive and
Standards.
QUICK START GUIDE
TABLE OF CONTENTS
CHAPTER 1
INTRODUCTION.......................................................................................................................... 4–5
CHAPTER 2
CONTROLS..................................................................................................................................... 6–8
CHAPTER 3
SmartClass Fiber Devices...................................................................................................... 4
Key Features and Functions................................................................................................. 5
Operator Control Panel......................................................................................................... 7
Home Screen Display............................................................................................................. 8
OPERATION.................................................................................................................................9–11
Setting Up PASS/FAIL Analysis............................................................................................ 9
Activate inspection with PASS/FAIL analysis...................................................... 9
Select acceptance criteria: Inspection (PCM)..................................................... 9
Select acceptance criteria: Inspection (Probe).................................................10
Set up OPM PASS/FAIL thresholds (if measuring in dBm)............................10
Using the Device....................................................................................................................11
SmartClass™ Fiber FBP-HD4i/HD4iP and OLP-82/82P
3
CHAPTER 1
SmartClass™ Fiber FBP-HD4i/HD4iP and OLP-82/82P
INTRODUCTION
1
JDSU’s SmartClass Fiber family is the next generation of optical handheld test solutions that allow
technicians to inspect, test, certify, and save on a single device. Designed to help users work smarter and
faster, the SmartClass Fiber family incorporates the features that technicians rely on every day to deliver
best-in-class reliable networks to their customers.
Products in the SmartClass Fiber family include:
4
HD4i
OLP-82
OLP-87
Digital handheld video
display
Digital handheld video
display with optical power
meter
Digital handheld video
display with PON power
meter
QUICK START GUIDE
Introduction
CHAPTER 1
Key Features and Functions
Description
HD4i
OLP-82
OLP-87
HD4iP
OLP-82P
OLP-87P
Portable handheld display with 3.5" color touch screen
Simple graphical menu-driven interface
Accepts PASS/FAIL P5000i Probe
Accepts external USB power meter
Integrated connector certification reporting
On-board storage: Endface images and inspection analysis
User-definable acceptance criteria
Integrated optical power meter
On-board storage: Power meter results
Integrated PON power meter (BPON, EPON, and GPON)
Integrated PASS/FAIL patch cord microscope option
This Quick Start Guide highlights general controls and use the HD4i and OLP-82 products only.
A comprehensive User Manual is included on the FiberChekPRO installation disk that is included with this
product.
For further information on the OLP-87 or other JDSU fiber test tools, visit www.jdsu.com/test.
SmartClass™ Fiber FBP-HD4i/HD4iP and OLP-82/82P
5
CHAPTER 2
SmartClass™ Fiber FBP-HD4i/HD4iP and OLP-82/82P
CONTROLS
2
Standard
with Patch Cord Microscope (PCM)
y
u
z
{
|
v
w
x
}
~
6
QUICK START GUIDE
Controls
u
v
w
x
y
z
{
|
}
~
CHAPTER 2
Connector interface
3.5 inch color touch screen
Key pad (operator control panel)
LED indicators
Patch Cord Microscope (PCM) with FMAE adapter
Test head cover
Battery life indicator
Graphic menu interface
2x USB2 interfaces, 1x micro-USB interface, external power supply connector
PCM controls (focus control, automated PASS/FAIL analysis, magnification control)
Operator Control Panel
HOME - Press to go to the home screen
MENU - Press to open a menu
BACK - Press to go back one step
INPUT SELECT KEY (ISK) - Press for fast toggling between device functions
POWER - Press to switch the instrument ON and OFF
NOTE: LED glows GREEN when the instrument is ON.
ARROW KEYS
• Press to navigate through the menus
• Press to change values in the menus
CENTER KEY
• Press to confirm the selection
SAVE - Press to save results
LOW BATTERY - Glows RED when battery is low
TEST IN PROCESS - Glows RED when a measurement is running in the background
CHARGE - Glows AMBER when battery is charging; If the power is OFF, charging will continue with no
LED indicator
SmartClass™ Fiber FBP-HD4i/HD4iP and OLP-82/82P
7
CHAPTER 2
SmartClass™ Fiber FBP-HD4i/HD4iP and OLP-82/82P
Home Screen Display
OLP-82P Home Screen shown
Battery Status - Indicates the battery charge level / status.
Optical Power Meter (OPM) - Activates the on-board OPM to view optical power
measurement results, edit acceptance criteria, and view saved results.
Inspect (PCM) - Activates the integrated Patch Cord Microscope (PCM) to inspect
and analyze fiber endfaces, detect scratches and defects, and provide PASS/FAIL
results. The PCM is ideal for inspecting male fiber connectors such as patch cords
and test leads.
Inspect (Probe) - Activates the handheld P5000i Digital Probe microscope to
inspect and analyze fiber endfaces, detect scratches and defects, and provide
PASS/FAIL results. The probe is ideal for inspecting connectors located behind
bulkheads.
USB Optical Power Meter (OPM) - Activates OPM devices (such as MP-60 or
MP-80) that are connected to one of the USB ports to view optical power
measurement results, edit acceptance criteria, and view saved results.
8
QUICK START GUIDE
Operation
CHAPTER 3
OPERATION
3
Setting Up PASS/FAIL Analysis
Select Acceptance
Criteria:
Inspection (Probe)
1.
Open the
2.
Press
INSPECT (Probe) application
MENU
3. Select PROFILE (choose desired PROFILE from list)
4. Select TIP (choose from list)
Select Acceptance
Criteria:
Inspection (PCM)
1.
Open the
2.
Press
INSPECT (PCM) application
MENU
3. Select PROFILE (choose desired PROFILE from list)
SmartClass™ Fiber FBP-HD4i/HD4iP and OLP-82/82P
9
CHAPTER 3
SmartClass™ Fiber FBP-HD4i/HD4iP and OLP-82/82P
Set Up OPM
PASS/FAIL
Thresholds
(if measuring in
dBm)
1.
POWER METER application
Open the
2. Select MORE... > EDIT WAVELENGTH TABLE
3. Select a wavelength from the list
4.
Press
MENU
5. Select ENTER LIMIT
6. Enter you desired limit value (measured in dBm) using the numeric keypad
7. Press OK
• Repeat steps 4–7 for all desired OPM wavelengths
8. Check the boxes for only the wavelengths you want to use
10
QUICK START GUIDE
Operation
CHAPTER 3
Using the Device
This SmartClass Fiber device allows users to inspect, test, certify, and save results
quickly and easily by driving the user’s behavior and incrementally stepping
them through each application as it should be used in a proper testing
workflow as follows:
Starting from the Home Screen
1.
Certify the patch cord/test lead endfaces
a.
Press the
to activate the PCM
b. Inspect patch cord/test lead end A using the PCM
c.
Press the [TEST] button on the PCM
d.
Press
e.
Move end A over to the OPM port
f.
Inspect patch cord/test lead end B using the PCM
to save result (if necessary)
g. Press the [TEST] button on the PCM
2.
h.
Press
i.
Leave end B in the PCM
to save result (if necessary)
Certify the bulkhead connector endface
a.
Press the
to activate the Probe Microscope
b. Inspect the bulkhead endface using the Probe Microscope
3.
c.
Press the [TEST] button on the Probe
d.
Press
e.
Plug patch cord/test lead end B into the bulkhead port
to save result
Measure the optical power
a.
Press the
to switch to the OPM
b. Select desired wavelength (OPM value will be displayed on the screen)
c.
Press
d.
Repeat as necessary for other wavelengths
to save result
SmartClass™ Fiber FBP-HD4i/HD4iP and OLP-82/82P
11
Test and Measurement Regional Sales
NORTH AMERICA
TEL: 1 866 228 3762
FAX: 1 301 353 9216
LATIN AMERICA
TEL: +1 954 688 5660
FAX: +1 954 345 4668
ASIA PACIFIC
TEL: +852 2892 0990
FAX: +852 2892 0770
EMEA
TEL: +49 7121 86 2222
FAX: +49 7181 86 1222
Product specifications and descriptions in this document subject to change without notice. © 2012 JDS Uniphase Corporation.