The Quad Ancillary Modules form a
versatile new range of multiple input
and output modules for use with MZX
technology systems.
The range consists of:QIO850 - Quad input / output module – provides four
monitored inputs and four relay / HVR outputs
QMO850 - Quad monitored output module – provides four
monitored outputs
QRM850 - Quad relay output module – provides four relay
/ HVR outputs
The modules are designed for compactness and ease of
installation. They share a number of common features that
provide many user benefits across multiple applications.
Features
// Compact DIN rail mount design saves space
// Lower installation costs than individual modules
// Built-in line isolators improve fault tolerance
// Status LED’s provide rapid diagnostics
// Two way IR communication to the 850EMT programming tool speeds up commissioning
// Monitors input power supply for improved system
integrity
// VdS and CPD approved to EN54-17, EN54-18 and
EN54-13
Safer. Smarter. Tyco.™
PSF260T.indd 1
13/12/2012 12:28:06
Quad Ancillary Modules
Quad Input/Output Module (QIO850)
The Quad Input/Output Module connects directly to the MZX
Digital loop and provides four change over relay outputs, four
High Voltage Relay (HVR) outputs and four monitored inputs. It
is loop powered and therefore does not need a power supply,
however it can monitor the presence of a local 24Vdc or 48Vdc
power supply.
Features:
// Four change over relay outputs and four monitored inputs each individually programmable for a wide range of applications
// Four HVR drivers. No need for a local power supply to switch 240Vac mains
// Inputs can monitor normally open or normally closed
contacts
// The relay contacts are monitored and users are alerted to
“output stuck” conditions
// Uses 2 addresses when configured for 2 inputs with 2
associated outputs
// Uses 4 addresses when configured for 4 inputs with 4
associated outputs
// Uses 8 addresses when configured for 4 inputs and 4
independant outputs
Applications
//
//
//
//
//
//
//
//
BS7273-4 door monitor and control (UK only)
Damper control
Sprinkler monitoring
Interface to conventional systems / shop interface
Interface to medical gas panels / gas detection systems
Interface to extinguishing systems / 3rd party detectors
Local isolation input and control
240VAC secondary sounder monitor and control via an HVR module
Quad Monitored Output Module (QMO850)
The Quad Monitored Output Module connects directly to the
MZX Digital loop and requires a 24Vdc or 48Vdc power supply. It
provides four monitored outputs for connection to conventional
sounder circuits or auxiliary relays.
Features:
//
//
//
//
Four polarity reversal monitored outputs
Class A or Class B wiring for versatility
Uses 2 addresses when configured for 2 outputs
Uses 4 addresses when configured for 4 outputs
Applications
// Conventional sounder monitor and control
// Aux relay monitor and control
PSF260T.indd 2
13/12/2012 12:28:09
Quad Ancillary Modules
Quad Relay Output Module (QRM850)
The Quad Relay Output Module connects directly to the MZX
Digital loop and provides four change over relay outputs or
four High Voltage Relay (HVR) outputs. It is loop powered and
therefore does not need a power supply, however it can monitor
the presence of a local 24Vdc or 48Vdc power supply.
Features:
//
//
//
//
//
Four change over relay outputs each individually
programmable for a wide range of applications
Four HVR drivers. No need for a local power supply to switch 240Vac mains
The relay contacts are monitored and users are alerted to
“output stuck” conditions
Uses 2 addresses when configured for 2 outputs
Uses 4 addresses when configured for 4 outputs
Applications
//
//
//
//
PSF260T.indd 3
A/C control
Plant control
Smoke control systems
Lift control
13/12/2012 12:28:10
Quad Ancillary Modules
QIO850
System Compatability
QMO850
QRM850
Any MZX Fire Alarm Controller configured with MZX Consys Version 20.0 or later
Mechanical
Dimensions (H x W x D)
103 x 134 x49 mm
Weight (kg)
0.15
Eelectrical
Voltage
Current
40VDC
1.1 mA (standby), 5.9 mA
(alarm)
2.1 mA (standby), 6.7 mA
(alarm)
0.5mm2 to 2.5mm2
Wire Size
Output Circuit
(Relay Contacts)
Auxiliary Voltage Input
1.1 mA (standby), 5.9 mA
(alarm)
Nominal switching capacity 2A at 30VDC (resistive load),
Maximum switching power 60W, 125VA (resistive load)
Auxiliary voltage 24VDC
to 55VDC (threshold voltage
for auxiliary voltage
fault indication:
18VDC +/- 1VDC).
Auxiliary voltage 48VDC to
55VDC (threshold voltage
for auxiliary voltage indication
36VDC +/- 2VDC).
Auxiliary voltage 24VDC
to 55VDC (threshold voltage
for auxiliary voltage fault
indication: 18VDC +/1.5VDC).
Auxiliary voltage 48VDC to
55VDC (threshold voltage for
auxiliary voltage indication:
36VDC +/- 2.5VDC).
Wiring monitoring (threshold
resistance for auxiliary
voltage fault indication
50 ohms +/- 5 ohms).
Auxiliary voltage 24VDC
to 55VDC (threshold
voltage for auxiliary voltage
fault indication: 18VDC
+/- 1VDC). Auxiliary voltage
48VDC to 55VDC (threshold
voltage for auxiliary voltage
indication 36VDC +/- 2VDC).
Environmental
Operating Temperature
-25oC to +70oC
Storage Temperature
-40oC to +80oC
Operating Humidity
Up to 95% Non condensing
Electromagnetic
Compatability
EN50130-4 for immunity
EN61000-6-3 for emissions
Approvals
EN54-17, EN54-18 and EN54-13
Ordering Information
555.800.071 Quad Input/Output Module (QIO850)
555.800.070 Quad Monitored Output Module (QMO850)
555.800.073 Quad Relay Output Module (QRM850)
Thorn Security is a leading brand of fire detection products in the Middle East market. The Thorn Security fire detection product line includes a wide range of MZX
TECHNOLOGY EN54 CPD approved fire detection products carrying approvals and cross-listings, including LPCB and VdS. The Thorn Security product lines are
available through Thorn Security dealers in the Middle East. For more information, visit www.ThornSecurity.net or contact us by e-mail at thornsecurity@tycoint.com.
PSF260T - December 2012
Safer. Smarter. Tyco.™
PSF260T.indd 4
13/12/2012 12:28:10
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising