Storm Pro欧
Registrate by scanning
Storm Pro
DEHUMIDIFIERS
DEHUMIDIFIERS
※Safety Notes※
Ÿ
The ALORAIR Series Dehumidifier must always be connected using a grounded
※Table of Contents※
Features/Specs.............................................................................................................................. 01
electrical connection as required for all electrical appliances. The warranty is voided and all
responsibility for the operation transfers to the owner if non-grounded wiring is
Identification................................................................................................................................. 01
utilized.ALORAIR Dehumidifiers must be maintained and serviced by qualified technicians.
Ÿ
ALORAIR Dehumidifiers are intended for use only when the unit is installed in a level
and upright position. Operating the unit in any other position could cause water to come
in contact with the electrical components.
Ÿ
Before moving the dehumidifier, turn off dehumidifier and allow pump to empty
How Your Storm Dehumidifier Works.................................................................................... 02
Unit Overview................................................................................................................................ 03
Operating instructions................................................................................................................ 04
reservoir. (Or if unit is already off, press“P”button to confirm drain reservoir is empty).
After the pump has finished operation, unplug the power cord and relocate unit to the
Preparing the Unit for Use.......................................................................................................... 10
desired position.
Ÿ
If the inside of the unit has gotten wet for any reason, the unit should be opened
and allowed to dry thoroughly before reconnecting to electric and restarting.
Ÿ
For proper operation, neither the inlet nor discharge should be positioned against a
wall. A minimum of 12”clearance between unit and any obstruction is required.
Ÿ
Do not insert any objects or fingers into the inlet or discharge.
Ÿ
All work on unit should be done with the unit“off”and unplugged.
Ÿ
Do not use water to clean unit exterior. Only use a damp cloth to clean exterior and
always unplug the unit first.
Ÿ
Do not use unit as shelf or device to hang clothes. This could cause damage to unit.
Ÿ
Do not stand on machine.
Maintenance.................................................................................................................................. 12
Storing Your Dehumidifier.......................................................................................................... 16
Troubleshooting........................................................................................................................... 16
Warranty......................................................................................................................................... 18
Congratulations on purchasing a ALORAIR Dehumidifier! Your new dehumidifier
comes with an extensive warranty plan.
Have your serial number handy for the registration process.
DEHUMIDIFIERS
DEHUMIDIFIERS
※Features/Specifications※
The Storm Series dehumidifier operates based on the refrigerant principle of
dehumidification.
How Your Storm Dehumidifier Works
The ALORAIR Storm Series Dehumidifier utilizes either its integral humidistat to
monitor the conditioned space or a manual on/off control to energize the compressor
when needed. Air is drawn across an evaporator coil. The evaporator coil is cooler than the
dew point of the air so water vapor will turn into liquid condensation. Air is then reheated
High Cop,3.0L/KWh
Low Sound Levels <50dBA
Eco-Friendly R410A Refrigerant
Self-monitoring system
Easy access for routine maintenance
Pump safety feature – overflow protection
through the condenser coil and distributed back into the room.
Installation:
Drain Pump with both Automatic and Manual Control
Automatic (Humidistat) or Manual Control
WARNING!
120 Volts AC may cause serious injury from electric shock.
Unit can be ducted, if necessary
1. Disconnect electrical power before servicing
3. Do not use extension cord
Each unit comes standard with a prefilter and Merv 8 filter. High efficiency
and carbon filters are available as options.
2. Only plug unit into grounded electrical outlet
4. Do not use plug adapter
If power is interrupted during operation, the unit will automatically
restart when power is restored.
Identification:
Power Supply:
220V, 50 Hz AC Only 1 Phase
Outlet Requirement:
3-Prong, GFI
Circuit Protector:
15 Amp Time Delay Fuse or Circuit Breaker
Alternatively, you can manually control unit to operate independent of space conditions.
For future reference, write down the model, serial number, and date of purchase so
Place unit in desired location. The inlet of unit should be at least 8”from any
you can identify your unit when seeking assistance. NOTE: data label on back of unit
obstructions. If unit is transported in the horizontal position, allow it to sit in upright
includes serial number.
position for at least 30 minutes before operating.
Model Number
Storm Pro
Serial Number __________________________
Date of Purchase __________________________
WARNING!
It is recommended that the unit be removed from any location where corrosive or high
Customer Service:
For additional questions concerning the operation of your dehumidifier,
VOC content materials are applied.
please:
Contact your installing contractor
E-mail: sales@alorair.com
-1-
-2-
DEHUMIDIFIERS
DEHUMIDIFIERS
※Unit Overview※
※Operating instructions※
Select/OK
Front View
Menu
Front cover
Secured Access
Latch
Up Button
Drain Pump
On/Off
M
Handle
Air Filter
P
OK
Down Button
LCD Monitor
※ Control Panel Operation
1. ON/Off Button
Wheel
Air inlet
Press this button, and the machine will start running. Press this key again and the
machine will stop running. The display will show room humidity levels except while you’re
pressing another button. NOTE: When unit is turned off, the fan will run for 1 minute prior
to shutting off. “ In addition the condensate pump will pump for approximately 14
seconds to drain the pump reservoir after unit is powered off.”
※ Rear View
2. Pump Button
P
For extended storage or movement of the machine, press the“Pump”bottom to
remove water from the integral pump’s reservoir.
Control panel
Air outlet
3. Menu Button
M
Pressing the Menu (M) button, gives you the options to select between two different
Hose and
Cord Rack
control modes as well as adjust the temperature measurement units. Continue pressing
the M button until you get to your desired selection. Press the Select (OK) key to confirm
that selection and move to a submenu.
Drain Tube
Connection
Power Cord Input
After you’ve completed your task, select“R”,then press the“select/ok”button to
move back to previous menu, or wait 10 sec to automatically return to the main screen.
Four selections are available:
-3-
-4-
DEHUMIDIFIERS
DEHUMIDIFIERS
Humidity Setting: Adjust the humidity setpoint
The contents of the second line alternate every 10 sec.
Timer Setting: Start Time Setup/Stop Time Setup/Cycle Time Setup
.
T
H u m i
.
J
Temperature Scale Switch: Choose between Celsius and Fahrenheit readings
o b
or
Return: Return to the main menu
0
s
e
0
t
0
5
5 0 %
NOTE: See Section 8 for more detailed programming instructions.
(4)When you press the“Power Off”button, two lines of data will be displayed. The
OK
4. Select/OK Button
top line will read“Unit Off”. The bottom line will read“Draining”for approximately 14
Use to confirm a selection.
5. UP Botton
seconds while the pump is emptied.
Down Botton
U n
r
D
These buttons are used for adjusting humidity or timer settings.
i
a
t
i
n
O f f
i n g
Once the pump reservoir is drained, the contents of the second line alternately show “job hours”
6. LCD monitor
and “total hours”, alternating every 10 seconds until the one minute final fan cycle is completed.
When the unit is running, the LCD monitor will go dark if no buttons are pushed. Push
any button once to light monitor.
J
o b
.
T
L
i
e
.
or
7. LCD display function
(1)Show“Power On”when the machine has already connected but not started.
p o w e
H
0
0
0
0
5
8
9
(5)Show “D raining ”w hen t he p ump i s d raining i n b oth a utomatic a nd m anual
modes.
o n
r
f
0
I
n
l
e
t
D
r
3
a
i
7 6 %
2 ℃
n i n g
(2) Show“Unit On”when the machine is in working status (This display will change
Show“Defrosting”when the machine is in defrosting mode. If both“Defrosting”and
to next screen in 2 seconds).
“Draining”are occurring simultaneously,“Defrosting”is the display priority.
The contents of the second line alternate every 10 sec.
U n
i
I
O n
t
(3)The LCD interface shows two lines of data. The first line displays the room temperature
and humidity. On the second line, Job T(working time) and Humidity Setpoint are displayed
n
l e
D e
t
f
r
3 2 ℃
o s t i
(6) Second line of display will rotate through several screens depending on setup.
U n
i
t
O f
on an alternating basis.
I
n
l
e
t
3
2 ℃
-5-
7
7 6 %
n g
6 %
-6-
f
DEHUMIDIFIERS
DEHUMIDIFIERS
( 2 ) Timer Settings (Timer)
Second screen display options:
J
o b
.
L
i
e
T
0
0
0
5
8
9
This selection allows you to set a timer for the unit to turn on or turn off. You can also set up cycle
timing, which allows you to set up and repeating cycle of specific on and off durations.
or
f
.
H
0
0
a. Press the menu key several times unit the Timer button is flashing.
Press“OK”button to confirm this option.
Time remaining to Auto opening
T
i
m e
O n
0
0
0
H u m i d
T e m p U
5
Time remaining to Auto Closing
T
i
m e
O f
0
f
0
0
0
0
1 0
O 0
0
i m e
r
R
c. The screen shows: T. on, T. off, T.I / 0,R
5
Time remaining to circulate status
I
T
1 0
T
.
o n
T
.
I
/
T
.
o
f
f
R
0
8. Operation and Display
Note: As long as the machine is plugged into power, the settings can be changed. The unit does
not have to be operating to change setup.
“T.on” – Unit will start when timer expires
“T.off” – Unit will stop when timer expires
“T.I/O” – Unit will cycle“on”and“off”based on the set time. If unit is off, the
( 1 ) The Humidity Setting (Humid)
cycling will start with unit“off”. If unit is on, the cycling will start with the unit“on.”
a. Press the Menu (M) button. The screen shows:
H u m i d
T e m p U
d. Press the menu key to select your desired selection.
i m e
T
r
1) Start Time (T.on Selection)
R
a. Press to confirm key. The screen runs as follow, the first 00 positions (flashes) at the
same time.
b. Press the“M”button until “Humid”is flashing. Press “OK”to select this option.
The screen shows:
H u m i
3
d
S
e
5 %
t
t
i
T
i m e
r
O n
0
0
0
O f
0
R
n g
R
c. Press the menu key until the humidity level (bottom left of display) is flashing (it will
either say“Co”f or continuous operation or a number for a specific percentage).
d. Use the“Up”or“Down”buttons to set the machine to your desired level. Press the
“OK”button when finished. The cursor automatically move to“R”which will be flashing.
Press“OK”to confirm move to previous menu or wait 10 seconds and you will
b. Press“Up”and“Down”key to select hour choice between 00-24. Press“Ok”key
to select choice.
c. After the hour selection is confirmed, the minute choice will flash. Select as before
and confirm with“Ok”key.
d. The“OFF”button will now flash. Press“OK”one more time, the“OFF”display will
switch to“ON”and the timer is now set.
automatically return to the main menu.
-7-
f
-8-
DEHUMIDIFIERS
DEHUMIDIFIERS
2) Shut Off Time (T.offSelection). Unit will run for designated time and then turn off.
9.Optional Duct Installation
a. Press the M button until the T.off button is flashing. Press“OK”to confirm.
Ducting of the unit allows conditioning of an adjacent room or focusing discharge in
b. Set timer as above.
an area needing focused attention. Diameter for supply ducting is 6”. Flex or layflat
3) Cycling Timer (T.I/O Selection)
ducting can be used for this purpose.
The third selection, T.I/O, lets you set up the machine to cycle on and off during a
specific time frame. For example, you could set the unit to run 8 hours a day and remain
off the other 16 hours. Note: You are selecting on and off periods of time, not set clock
Discharge Ducting
times.
a. Press the M button until the T.I/O selection is flashing. Press“OK”button to select.
b. Use the“Up”and“Down”arrows to adjust the hours and minute of the first cycle.
c. Use the“M”button to move from 1st line of display to second and adjust second
time period with up and down buttons.
d. Press the“OK”button to confirm the time. (Flashing OFF will turn to ON).
( 3 ) Temperature scale set
This selection allows you to switch the machine from displaying temperature in
degrees Celsius to degrees Fahrenheit.
a. Press the menu key. The screen shows: Humid, Timer, Tempu, R.
H u m i d
T e m p U
T
i
m e
r
R
b. Press the Menu key unit TempU flashes. Press“OK”to select.
( 1 ) Position the machine for a minimum 8”clearance on front and sides. Rear of
c. The screen shows: Celsius degree℃ on/off and Fahrenheit degree the ℉ off/on.
T
℃
e m p U
O n
S e
o
F
t
t
i
O
f
f
n
※Preparing the Unit for Use※
machine should be positioned for maximum discharge distance or directly towards a
specific location for spot drying.
g
R
If the unit was moved in such a manner that the compressor didn’t remain in a
vertical orientation, wait a minimum of 30 minutes before turning the unit“on.”
d. Press the menu key to move the cursor to the ℃ on/offor ℉ off/on(flashes).
e. Press to confirm key. The on/off status of C and F will exchange.
( 2 ) The included drain line attaches to the unit via a quick connection type fitting
located on the base of the unit.The drain line should be routed to a suitable drain or
outside. Because the unit features an integral drain pump, drain line may go vertically up
-9-
-10-
DEHUMIDIFIERS
DEHUMIDIFIERS
18’prior to reaching final drain location.
1) Pull up on the handle to
The quick connector into
the socket on the connector
Quick connection to draining tube
2) Remove the filter
release and gently pull out
on filter assembly.
b. Filter may be cleaned by vacuuming or by washing with warm water (no soap or solvents).
Insure filter is dry prior to restarting unit.
( 3 ) Firmly insert power cord into socket on top back of unit.
※Maintenance
( 4 ) Set unit control as desired and energize.
WARNING – ALWAYS UNPLUG UNIT PRIOR TO PERFORMING ANY
※Maintenance and Repair※
MAITENANCE
1. Accessing Internal Components
1. Exterior Cleaning
a. Remove tamperproof screws from side latches
Use a soft, slightly damp cloth to wipe the plastic body.
2. Filter cleaning
a. Remove the inlet grille to access the filter
-11-
-12-
DEHUMIDIFIERS
DEHUMIDIFIERS
Access screws for electrical
compartment
Release this screw at both side,
and open these box locks
Cover
Pump
b. Pull up the bottom to open
Press this button and pull to open
2. Water Pump Maintenance
The pump is designed with quick connection construction. If service is required,
condensate tube, float switch connections, and the main power cord to pump can easily be
disconnected. The pump can be removed from reservoir by using a flat screwdriver to
gently pry pump assembly from reservoir.
Your ALORAIR Storm is equipped with an integral condensate pump designed to
pump condensate from your dehumidifier out to the desired drain. This pump requires
routine maintenance that is not covered by your 1 year parts warranty. Only a defective
c. Opening back housing
pump will be repaired or replaced during the warranty period.
Preventative Maintenance
As with all pumps, preventative maintenance is necessary to prevent issues from dirt
Hand in this
slot to open
-13-
and slime that may accumulate in the drain system – including the drain pan, hose to the
condensate pump, pump reservoir, pump head and float assembly, and discharge tubing.
-14-
DEHUMIDIFIERS
DEHUMIDIFIERS
※ At least once per year, clean pump system
Basic-
※Storing Your Dehumidifier※
If the unit will be stored for an extended period of time:
1. Turn unit off and allow to dry.
4. Clean the filter mesh.
2. Disconnect power to dehumidifier.
2. Manually drain pump reservoir.
5. Store in clean,dry environment.
3. Mix a 16 oz solution of either 1 oz bleach to 15 oz water or 4 oz white vinegar to 12
3. Wrap and secure the power cord .
1. Press the pump button (P) to drain water from reservoir.
oz water. Pour into the drain tray at the base of the coils.
※Troubleshooting※
Note: If you get any cleaning solution on the coils, flush with water.
4. Allow to soak for 15 minutes.
5. Reconnect power to dehumidifier.
Trouble
6. Fill reservoir and flush/cycle pump at least two times with clean water.
7. Repeat if needed or refer to Advanced instructions.
Machine Won’t Work/
Display is Blank
Advanced1. a. Use manual pump button“P”, to drain water from reservoir.
b. Unplug the dehumidifier and open cover to access pump.
c. Pump head can be removed from reservoir by pressing on tabs.
d. A wet-dry vacuum or towels can be used to remove remaining water from
Cannot start the
dehumidifier
cause
Display Blank. Power outage
or poor connection
Check Power Supply
Check both ends of power
cord for good connection
Room temperature outside unit
operating range. HI or LO Error
Modify room conditions in
between 33°F and 100°F.
Filter mesh is clogged
Clean the filter
Air inlet or outlet jammed
Clear the blockage from
air inlet or air outlet
Filter mesh jammed
Clean the filter
Unit is not level
Place unit on flat surface
in vertical orientation
Pump dislodged
Reassemble pump as necessary
Humidity Sensor or
communication error
Check sensor cable is properly
connected. Replace the Senser
reservoir.
2. Fill pump reservoir with a diluted cleaning solution (15 oz water to 1 oz bleach or 12
oz water to 4 oz white vinegar).
No Airflow
3. Reassemble pump and use manual pump button to flush mixture through discharge
tubing.
4. Pour same diluted mixture slowly into drain pan under evaporator coil and allow it
Loud/Unusual Noise
Solution
to clean hose from pan to pump. This process can be stopped when the pump energizes 1
Trouble code:E1
time.
Note: If you get any bleach/water mixture on coils, flush with water.
5. Pour sufficient clean water through drain pan to force pump to activate twice.
Trouble code:E4
Pump detected high water in
reservoir (See Notes Below)
Check for clogged drain lines
Check pump working properly
Service Pump、Replace Pump
Trouble code:L0
Unit is sensing room temperature
below 33°F.
Increase room temperature
Check Sensor
Check Sensor Cable
6. Reassemble unit and return it to operational status.
CoilIf necessary, clean your coils with a vacuum or approved coil cleaner.
-15-
-16-
DEHUMIDIFIERS
DEHUMIDIFIERS
Trouble code:HI
Unit is sensing room temperature
above 100°F
Decrease Room Temp
Check Sensor
Check Sensor Cable
Trouble code:E1,L0,HI
Shows E1, L0,HI at the same time
indicated a bad connection, cable
or sensor
Check Cable connection
Replace Cable
Replace Sensor
※Warranty※
Seller warrants the equipment to be free from defects in workmanship and materials
for a period of 12 months after shipment (60 months/5 years on compressor, evaporator
and condenser). This warranty is limited, however, to the repair or replacement of defective
equipment. If it is necessary to return unit for service, customer is solely responsible for
Pump Alarm-Error Code E4
If a pump alarm is provided on display:
proper packaging, transportation costs. Customer must initiate warranty process by
contacting factory. Do not send any component or product back to factory without Return
1. Clear error code by disconnecting power cord and then reconnecting. NOTE: Unit
Material Authorization.
will not function until error code has been cleared.
2. Manually check to see if pump is operational. Press pump button (P) and see if
This limited warranty does not apply to any part or component that is damaged in
pump energizes and de-energizes properly and if any water is purged from system. If you
transit or when handling, has been subject to misuse, corrosion, chemicals, acts of God has
haven’t cleaned the system recently, check discharge line for obstruction and clean
not been installed, operated or serviced according to the Seller’s instructions, or has been
balance of pump system per instruction above.
operated beyond the factory-rated capacity or has been altered in any way. Routine
3. Replace hoses and or pump if maintenance alone is not sufficient.
maintenance is not covered by this warranty.
Seller’
s liability is limited to replacement of defective parts or components and does
not include any cost of labor (including, but not limited to, labor to remove and/or reinstall
any defective part), refrigerant or piping. Customer may elect to have unit fixed locally in
which case required replacement parts will be sent to customer at customer’s expense.
ALORAIR shall not be responsible for loss of use
of any
product, loss of time,
inconvenience, or damage to other equipment, or any other indirect or consequential
damage with respect to property whether as a result of breach of warranty, neglect, or
otherwise.
THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER
WARRANTIES EXPRESSED OR IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE.
ALORAIR’
s total liability, regardless of nature of claim shall not exceed original purchase price
of the product. If a product or component is replaced while under warranty, the applicable
warranty period shall not be extended beyond the original warranty time period.
-17-
-18-
DEHUMIDIFIERS
The foregoing shall constitute the total liability of seller in the case of defective
performanceof all or any of the equipment or services provided to Buyer. Buyer agrees to
accept and hereby accepts the foregoing as the sole and exclusive remedy for any breach
or alleged breach of warranty by Seller.
-19-
Was this manual useful for you? yes no
Thank you for your participation!