Oscilloscope
TM
Oscilloscope
Features:
• • • • • • • 40MHz high bandwidth with 2 channels
100MSPS real time sampling rate
Multi-language support, easy to use
USB2.0 interface, no external power required
23 measurement functions, PASS/FAIL check, FFT
OS: Windows NT, Windows 2000, Windows XP, Windows 7
Labview/VB/VC SDK
Specifications:
Model
Acquisition
Input
72-10155
Sample Mode
Real-Time Sample
Sample Rate
100MSPS
Average
N acquisitions, all channels simultaneously, N is selectable
from 1-128
Input Coupling
DC, AC, GND
Input Impedance
Resistance: 1MΩ; Capacitance: 25pF
PP-80,PP-150,PP-200 Probe Attenuation 10X
Probe Attenuation Factors
1X, 10X
Maximum Input Voltage
35Vpk (DC + peak)
Scanning Speed Range(Sec/Div)
4ns/div ~ 1h/div(1-2-4 sequences)
Sample Rate and Delay Time Accuracy
±50ppm( any interval ≥1ms )
Wave form Interpolation
Step, Linear, Sin(x)/x
Horizontal
10K : available all timebase;
Memory Depth(Sample Points)
32K : 40µs/div-400ms/div(Dual channel); 20µs/div-400ms/
div(Signal channel);
64K : 40µs/div-400ms/div
Analog Bandwidth
40MHz (-3dB)
A/D converter
8 bit resolution
Vertical Scale(Volt/div) Range
Vertical
10mV ~ 5V/div @ x1 probe(1,2,5 sequence);
100mV ~ 50V/div @ x10 probe
Position Range
±4division
Selectable Analog
Bandwidth Limit(typical)
20MHz
Lower Frequency Response(-3dB)
≤ 10Hz(at input BNC)
Rise Time at BNC(typical)
≤8.8ns
DC Gain Accuracy
±3%
www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
www.mcmelectronics.com
TM
Page <1>
18/09/12
V1.0
TM
Oscilloscope
Trigger
Trigger Source
CH1,CH2, EXT
Trigger Mode
Auto, Normal and Single
Trigger Type
Edge trigger: Rising edge, falling edge.
Trigger Sensitivity
0.02 div increments
Trigger Level Range
±4V
Trigger Level Accuracy
±4 division
Amplitude difference between cursors (ΔV); Time difference
between cursors (Δt);
Cursor Measure
Reciprocal of Δt in Hertz (1/ Δt) (Cross, Trace, Horizontal,
Vertical)
Measurement
Voltage
Vp-p, Vmax, Vmin, Vmean, Vamp, Vtop, Vbase, Vmid,
Vrms, Vcrms,Preshoot, Overshoot
Time
Frequency, Period, Rise Time(10%~90%), Fall
Time(10%~90%), Positive Width, Negative Width, Duty Cycl
Auto Measure
Temperature
Environmental
Mechanical
Operating: 0°C to 40°C
Non-operating: -20°C to +60°C)
Cooling Method
Forced air
Humidity
Below +35°C, ≤90% relative humidity; +35°C to +40°C,
≤60% relative humidity
Altitude
Operating: 3,000m or below; Non-operating: 15,000m or
below
Size
190mm(L)×100mm(W)×35mm(H)
Heavy
Without Packaged 0.29kg; Packaged 0.9kg;
X1, X10 two passive probes. The passive probes have a
6MHz bandwidth (rated 100Vrms CAT III)
Probe
Accessories
when the switch is in the X1 position, and a maximum bandwidth (rated 300Vrms CAT II) when the switch is in the
X10 position. Each probe consists of all necessary fittings
USB Line
A USB A-B line, used to connect external devices with USB-B interface like a printer or to establish communications
between PC and the oscilloscope.
Installation CD
A software installation CD and it also contains the user
manual for the Tenma Oscilloscope.
Part Number Table
Description
Part Number
Oscilloscope, PC, 2 Channel, 40MHz
72-10155
Important Notice : This data sheet and its contents (the “Information”) belong to the members of the Premier Farnell group of companies (the “Group”) or are licensed to it. No licence is granted
for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change
without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any
error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the
Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its negligence.
Tenma is the registered trademark of the Group. © Premier Farnell plc 2012.
www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
www.mcmelectronics.com
TM
Page <2>
18/09/12
V1.0
Was this manual useful for you? yes no