Software Release Summary: Daniel MeterLink for Daniel

Software Release Summary: Daniel MeterLink for Daniel
Software Release Summary:
Daniel MeterLink for Daniel Gas and
Liquid Ultrasonic Flow Meters
Version 1.31
▪▪ Field Setup Wizard now supports Type 4 CPU Module with additional Frequency/
Digital Outputs 4 through 6.(1)
▪▪ Field Setup Wizard now supports the GC Modbus TCP interface configuration.
▪▪ Unit labels have been added to the chordal velocity and speed of sound tables that
appear in the Inspection Report.
▪▪ Additional technical enhancements:
◦◦ Fixed issue to ensure all column heading text displays correctly in the Meter
Archive Logs dialog.
◦◦ Fixed issue to enable the table of meters in the Connect to Meter dialog to
correctly display on any computer.
Version 1.30
▪▪ Added support for the diagnostic chord in the new dual-configuration Model 3416
Meter (i.e. alarm indication, configuration and charts).
▪▪ Regional dialogs updated to ensure data formatting, including the use of periods or
commas, is more consistent by locale.
▪▪ Field Setup Wizard now supports GC component data configuration for Daniel 3410
Series Electronics running on v1.22 firmware and later.
▪▪ Field Setup Wizard now supports local display mode configuration for Daniel
3410/3810 Series Electronics running on v1.22 firmware and later.
▪▪ Option added that allows the creation of a Merged Events worksheet in the
Microsoft® Excel® meter archive log.
▪▪ Automatically checks for software updates via the Internet.
▪▪ Fixed issue to ensure new meter database config XML files install correctly.
▪▪ Fixed issue where Excel 2013 charts were not visible.
▪▪ Fixed issue with Reset Tracking dialog.
▪▪ Fixed issue where Signal Analyzer caused MeterLink to crash or become
unresponsive.
▪▪ Corrected SOS spread error on the Meter Monitor bar chart for Daniel JuniorSonic
2-path meters.
Version 1.21
▪▪ Provides support for Mark III memory usage changes in Mark III v1.78 firmware.
Version 1.20
▪▪ Added advanced network configurations, including new wireless connectivity with
support for multiple Ethernet configurations. Designated ports now allow the use of
port forwarding on a cellular modem/router.
◦◦ This enhancement allows users to connect to multiple meters on a single IP
address (i.e. one modem).
◦◦ A new ‘Designated Ports’ help topic facilitates this network configuration.
▪▪ Dims non-pingable Ethernet connection buttons in the Connect to Meter dialog.
▪▪ Supports “Connect in a new instance” from the Connect to Meter dialog.
◦◦ This change allows log collection from multiple meters simultaneously to
streamline tasks, including monthly maintenance procedures.
▪▪ Simplifies the creation of a more functional default meter directory after initial
installation.
◦◦ This change ensures first-time users can quickly connect to meters.
Type 4 CPU Module releasing for sale in June 2016.
1
Page 1
June 2016
Software Release Summary: Daniel MeterLink for Daniel Gas and
Liquid Ultrasonic Flow Meters
Version 1.20 continued
▪▪ New time-saving Tools Menu enhancements include:
◦◦ Set Transducer Type utility.
◦◦ Reset Tracking utility which simplifies a common maintenance procedure.
◦◦ Reset Velocity Estimation utility.
◦◦ Locate Meter utility.
◦◦ Warm Start Meter utility which enables users to easily reboot from a remote
location.
▪▪ Additional enhancements for high viscosity liquid metering applications include:
◦◦ Support of profile factor frequency output content.
◦◦ Support of high viscosity calibration configuration.
◦◦ Support of zero calibration.
▪▪ Additional technical enhancements:
◦◦ Enables Microsoft Excel’s “Trust access to VBA” on start-up.
◦◦ Supports Microsoft Excel 2013.
Version 1.10
▪▪ Connects to co-located meters simultaneously from a single meter directory record
associated with either meter.
▪▪ Combined Meter Monitor (Summary) displays combined values from the currently
selected meter and values and status from both the primary and secondary meters.
▪▪ Field Setup Wizard supports local display configuration.
▪▪ Field Setup Wizard supports HART® 7 meter configuration.
▪▪ Displays the name of the currently connected meter in the title bar of dialogs and
wizards that read from or write to a meter.
▪▪ Supported on Microsoft® Windows® 8.1.
▪▪ Communications Analyzer’s output for TCP/IP communications includes the meter’s
IP address.
▪▪ Consolidates Program Download log output in the meter connection log (log_
meter_*.txt).
Version 1.01
▪▪ Bug fixes and data files added for Daniel 3410/3810 Series Ultrasonic Meters.
Version 1.00
▪▪ Installs separately from all earlier versions of Daniel CUI and replaces CUI for all
Daniel meters with the exception of Mark II equipped gas ultrasonic meters.
▪▪ Does not require a license key.
▪▪ Supports Daniel Gas Mark III, Liquid 3804, and 3410 and 3810 Series Ultrasonic
Meters.
▪▪ Direct/modem connections using SLIP no longer supported. Direct/modem
connections must use PPP.
▪▪ Contains registers help files for Daniel Gas Mark III, Liquid 3804, and 3410 and 3810
Series Ultrasonic Meters.
▪▪ Supports two meter monitor views: “summary” and “detailed.”
▪▪ Supports 3410 and 3810 Series’ HART output on AO1 and secondary HART output
on AO2.
▪▪ Edit/Compare Configuration simplifies upgrades by converting Mark II, Gas Mark III
and Liquid 3804 configs to 3410 and 3810 Series configs.
▪▪ Field Setup Wizard and Outputs Test dialog support the 3410 and 3810 Series’ softconfigurable frequency/digital (“FODO”) outputs.
Page 2
June 2016
Software Release Summary: Daniel MeterLink for Daniel Gas and
Liquid Ultrasonic Flow Meters
Version 1.00 continued
▪▪ Communications Settings dialog supports soft configuration of Port A’s driver
selection and optional Port B handshaking.
▪▪ Program Download dialog prevents Gas Mark III and Liquid 3804 Firmware from
being downloaded to 3410 and 3810 Series Ultrasonic Meters and vice versa.
▪▪ Has improved support for Microsoft Excel® 2007 and Microsoft Excel 2010.
Emerson Process Management
Daniel Measurement and Control, Inc.
North America / Latin America:
Headquarters
USA - Houston, Texas
T +1.713.467.6000
USA Toll Free 1.888.FLOW.001
Europe: Stirling, Scotland, UK
T +44.1786.433400
Middle East, Africa: Dubai, UAE
T +971.4.811.8100
Asia Pacific: Singapore
T +65.6777.8211
www.Daniel.com
Page 3
June 2016
©2016 Daniel Measurement and Control, Inc. (“Daniel”) is an Emerson Process
Management business unit. The Daniel name and logo are trademarks of Daniel
Industries, Inc. The Emerson logo is a trademark and service mark of Emerson
Electric Co. All other trademarks are the property of their respective companies.