CS1070 Power Amplifier Preliminary Data Sheet

CS1070 Power Amplifier Preliminary Data Sheet
Cleverscope Ltd
6 Oct. 2014 v1.2
Ihr Spezialist für
Mess- und Prüfgeräte
28 Ranfurly Rd, Epsom, Auckland 1023, New Zealand
Phone +64 9 524 7456 Fax
+64 9 524 7457
P.O. Box 26-527
Email support@cleverscope.com
CS1070 Power Amplifier
Preliminary Data Sheet
Summary
The CS1070 Power Amplifier is an accessory for the signal generators CS700A or CS701 to provide larger
signal with more output current. The Amplifier can swing 36Vpp with a ≥20VDC supply and provide up to
1A current. The Amplifier also includes an internal inverting power supply to provide the negative rail,
simplifying power supply requirements. The gain is fixed at x10 (20dB).
I sense
Amp out
>I
DC in
>V
V sense
On
Signal in
Internal Inverting Power Supply
The internal inverting supply tracks the DC input for voltages between 5 and 20VDC, and then limits the
differential voltage across the Amplifier to 40VDC for DC input voltages between 20 and 34VDC.
Some examples:
DC input = +6V
DC input = +18V
DC input = +32V
Negative supply = -6V.
Negative supply = -18V.
Negative supply = -8V.
Reverse polarity and over voltage protection for voltages from 34V to 60V are also included.
1
www.cleverscope.com
dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ info@datatec.de ▪ www.datatec.de
Frequency Response
The CS1070 -3dB frequency response is DC to 52MHz as shown in this spectrum taken with a CS328-FRA.
The CS1070 frequency response can be compensated using the “calibrate probes” function on the CS328FRA to give a flat response out to the full 65MHz bandwidth of the CS701 signal generator, as shown in this
spectrum where gain flatness is ±5mdB and phase flatness is ±0.025deg (note that the gain of 20dB has
also been calibrated out in this case).
2
2
www.cleverscope.com
dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ info@datatec.de ▪ www.datatec.de
Current and Voltage Sense Outputs
Apart from the main Amplifier output
there are also outputs to sense the
current and voltage supplied by the
Amplifier.
The voltage output is taken after the
Amplifier 1Ω output impedance and
shows the actual voltage on the load.
This signal is fed via 450Ω to the “V
sense” BNC, and gives 1V/V into high
impedance, or 100mV/V into 50Ω.
The current output is measured across
a 100mΩ sense resistor in the ground
return of the OUT BNC. This signal is fed via 50Ω to the “I sense” BNC, and gives 100mV/A into a high
impedance, or 50mV/A into 50Ω. Note that the I Sense output can only be used with isolated loads, such as
transformers. If the load is referenced to the same ground as the I sense BNC then the sense resistor is
shorted and will not give a reading. For example if both OUT BNC and I sense BNC are connected to an
oscilloscope input.
Here the I sense output is
being used to measure the
primary current while
characterising a current
transformer. 2Vpp output
with 1Ω output impedance
give approx 2App primary
current.
Red = gain, blue = phase.
3
3
www.cleverscope.com
dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ info@datatec.de ▪ www.datatec.de
Amplifier Input and Output
The Amplifier input signal is terminated internally with 50Ω. When using with a 50Ω source such as the
CS701, remember to take into account this x0.5 attenuation, so for example a 1Vpp setting on the signal
generator will give 5Vpp on the Amplifier output.
The Amplifier output impedance is 1Ω for stability when driving capacitive loads. The Amplifier output can
be disabled with the switch on the front panel (Up = disable).
In case of an overload condition the Amp output is disabled and the >I LED turns on. The Amp output can
be re-enabled with the ON switch.
Warning: Do not short the output when the supply voltage is >20VDC. Otherwise the amplifier
output may be damaged.
Output Current De-rating
For supply voltages >18VDC the output current must be de-rated as shown in the following graph. The
graph shows the difference between Vin (supply voltage) and Vout (voltage on amplifier output) as this is
what limits the current rating on the amplifier output stage.
Output Current (A)
1.2
1
0.8
0.6
0.4
0.2
0
0
5
10
15
20
25
30
35
40
Vin - Vout (V)
Say for example the CS1070 is being used to test the PSRR of a 24Vin regulator. The CS1070 supply voltage
could be set to 34VDC and the output is set to 24VDC with a 1VACPP sine wave superimposed. In this case VinVout = 10VDC so the full 1A output current is available.
In another example, the CS1070 is used to test the response of a current transformer. In this case the
output is shorted by the primary turn of the CT. If the CS1070 is powered with the wall adaptor at 18VDC
and the output current is 1A there will be a 1V drop across the internal 1Ω resistor. So Vin-Vout = 17VDC
which is within the Safe Operating Area (SOA) as shown in the graph. If however the supply is increased to
say 25VDC then the SOA will be exceeded and the amplifier output may be damaged.
For use with high output current into a low impedance load it is recommended to reduce the supply
voltage (e.g. 5VDC) to reduce power dissipation in the CS1070.
4
4
www.cleverscope.com
dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ info@datatec.de ▪ www.datatec.de
Ihr Spezialist für
Mess- und Prüfgeräte
5
Item
Value
Frequency Range:
0 - 52 MHz (-3 dB)
Gain:
x10
Slew Rate:
1700 V/µs (Vsupply = ±20V Vout = 20Vp-p)
Noise:
2.1 nV/√Hz (input referred)
Harmonic Distortion:
Vsupply = ±20V Vout = 20Vp-p
100 kHz: -95 dB
1 MHz: -75 db
10 MHz: -45 dB
30 MHz: -38 dB
Input Impedance:
50 Ω
Output Impedance:
1Ω
Output current:
1A (de-rated for Vin-Vout > 17V)
Current Sense Out:
100 mV/A open, 50 mV/A into 50 Ω
Voltage Sense Out:
1V/V open, 100 mV/V into 50 Ω
Power Supply Range:
5 – 34 VDC, 1 Amp minimum. Over voltage protection: 34 to 60 VDC.
Reverse protection: 0 to -60 VDC.
Power Supply Connector:
2.1 or 2.5mm ID, 5.5mm OD, center +Ve.
Power Supply Included:
Wall adaptor with US, UK, EU plugs. Input: 90-264 VAC, 47-63 Hz. Output: 18
VDC, 1.33 Amp, 2.1x5.5mm DC Jack.
Power Supply Cable
Included:
DC Jack with 1m cable terminated in 4mm banana plugs for use with bench
power supply.
Amp Enable Switch:
Down = Amp Enable, Up = Amp Disable.
LED Indicators:
Over Voltage, Over Current, Amp On.
Änderungen und Irrtümer vorbehalten. dataTec 15-04-2016 | Update CleverScope: 6 Oct. 2014 v1.2
Specifications
dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ info@datatec.de ▪ www.datatec.de
Ihr Spezialist für
Mess- und Prüfgeräte
STARKE MARKEN. HÖCHSTE PRODUKTVIELFALT. BESTE QUALITÄT.
Schnell und bequem online bestellen – bei dataTec ist das möglich. Bei uns finden Sie die perfekte Lösung für ihre vielfältigen Anforderungen.
Wir bieten eine unschlagbare Auswahl an Mess- und Prüfgeräten namhafter Hersteller. Diese reicht von
Arbiträr-Funktionsgeneratoren über Logikanalysatoren bis hin zu Stromversorgungen und Stromzangen
oder Oszilloskopen bis 90 GHz Bandbreite. Hohe Lagerkapazität und kurze Wege sorgen dafür, dass
die gewünschte Ware ganz schnell bei Ihnen ist. Bundesweit meist innerhalb eines Tages.
Mehr Klicks, mehr Vorteile:
Mehrere tausend Mess- und Prüfgeräte
Tagesaktuelle Preise und Promotions
Warenkorbrabatt bei Onlinebestellung
Angebotsanfrage oder Bestellung unter:
6
Versandkostenfrei (ab € 80,-)
Datenblatt-Download
uvm.
B2LIB
NEON
SHOP
dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ info@datatec.de ▪ www.datatec.de
Ihr Spezialist für
Mess- und Prüfgeräte
KOMPETENTE BERATUNG VOR UND NACH DEM KAUF.
Haben Sie eine technische Frage zu den Geräten, zum Handling und Bedienung eines Gerätes, zur
passenden Software und / oder bei der Auswahl des richtigen Equipments für Ihre Messaufgabe?
Bei uns kümmern sich echte Diplom-Ingenieure, Elektronik- und Elektrotechniker mit langjähriger
Praxiserfahrung und hoher Kompetenz um Ihr Anliegen. Kostenlos berät Sie unser praxiserfahrener
und herstellerzertifizierter Außendienst direkt bei Ihnen vor Ort und / oder führt Ihnen live das gewünschte Mess- und Prüfgerät vor.
Die technischen Experten für:
Oszilloskope
Spektrum- / Netzwerkanalysatoren
Netzgeräte / Stromversorgungen
Thermografie / Temperatur
Prüfgeräte VDE / Netzanalyse
uvm.
Technische Frage oder Termin vereinbaren unter:
7
ICHE
BINDL
UNVER
UNG
T
A
R
E
B
T
R
VOR O
dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ info@datatec.de ▪ www.datatec.de
SEMINARE IN THEORIE UND PRAXIS.
Der Kauf von Mess- oder Prüfgeräten bei dataTec ist der erste Teil zur Lösung Ihrer Messaufgabe. Ist die
Messtechnik beschafft oder bereits vorhanden, steht das Thema Umsetzung in Ihrer täglichen Arbeit an.
Die dataTec Akademie hält Ihr Wissen zu vielen Bereichen der Messtechnik stets auf dem neuesten
Stand. Nutzen Sie unser vielfältiges Seminarangebot mit renommierten Dozenten und transportieren
Sie aktuelles Wissen in Theorie und Praxis in Ihre tägliche Arbeit. Modernste Räumlichkeiten und beste technische Ausstattung – um das Erlebnis „Wissen“ angenehm und komfortabel zu begleiten.
Unsere Seminarthemen:
Thermografie
Prüfgeräte VDE
Oszilloskope
Labormesstechnik
EMV- / HF-Messtechnik
uvm.
ARSEMINHÜRE
BROSC
Alle aktuellen Termine und Preise unter:
TIS
GROA
!
RDERN
ANF
dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ akademie@datatec.de ▪ www.datatec-akademie.de
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising