m large display meter for digital input ldpf63000

m large display meter for digital input ldpf63000
LARGE DISPLAY METER
FOR DIGITAL INPUT
LDPF63000 shown
smaller than actual size.
LDPF63000
U Large LED Display
Readable to 21 m (70')
U Digital Input Module;
Count and Rate Input
Serial Slave
U Alarms, Analog Output,
and Communication
U Programmable
User Inputs
U Programmable
Function Keys
U PC Software for
Meter Configuration
U NEMA 4 (IP65)
The LDPF63000 display is a
versatile display that can increase
productivity by offering the plant
floor or production area a large
visual display of their current status.
Whether your measurement is rate
or count, the LDPF63000 can
satisfy your requirement. These
LDPF63000 displays accept various
digital inputs through the use of
input modules that allow the unit
to adapt to most any application.
Additional plug-in option cards can
add alarms, analog output, and
communication/bus capabilities,
making the LDPF63000 a truly
intelligent panel meter.
SPECIFICATIONS
Rate Display
Accuracy: ±0.01%
Minimum Frequency: 0.01 Hz
Maximum Frequency: 34 kHz
(depending on set-up)
Maximum Display:
6 Digits: 999999
Adjustable Display (Low) Update:
0.1 to 99.9 seconds
Counter Displays
Maximum Display:
8-Digits: ±99999999 (greater than
6-digits display alternates between
high order and low order)
M-X
Inputs A and B
DIP switch selectable to accept pulses
from a variety of sources including
switch contacts, TTL outputs, magnetic
pickups and all standard sensors
Logic: Input trigger levels vil = 1.5V
maximum; vih = 3.75V min
Current Sinking: Internal 7.8 kΩ
pull-up to 12 Vdc, imax = 1.9 mA
Current Sourcing: Internal 3.9 kΩ
pull-down, 7.3 mA maximum @ 28 Vdc,
vmax = 30 Vdc
Filter: Damping capacitor provided
for switch contact bounce. Limits input
frequency to 50 Hz and input pulse
widths to 10 msec minimum
Magnetic Pickup
Sensitivity: 200 mV peak
Hysteresis: 100 mV
Input Impedance: 3.9 kΩ @ 60 Hz
Maximum Input Voltage: ±40V peak,
30 Vrms
Dual Count Modes: When any dual
count mode is used, then user inputs
1 and/or 2 will accept the second signal
of each signal pair. The user inputs do
not have the Logic/Mag, High/Low Freq,
and Sink/Source input setup switches.
The user inputs are inherently a logic
input with no low frequency filtering.
Any mechanical contacts used for these
inputs in a dual count mode must be
debounced externally. The user input
may only be selected for sink/source by
the userjumper placement.
M
RS232 Communication Card
(LDP6-CDC20 or LDP6-CDC2C)
Prescaler Output
NPN Open Collector: isnk = 100 mA
maximum @ vol = 1 Vdc maximum voh
= 30 Vdc maximum with duty cycle of
25% min and 50% maximum
Display: 38 mm (1.5") red LED
Power: 85 to 250 Vac, 50/60 Hz, 18 VA
Annunciators: A, B, C, SP1, SP2, SP3,
and SP4
Keypad: Five tactile membrane
switches integrated into the front panel
Enviromental Conditions
Operating Temperature Range:
0 to 45°C (32 to 113°F)
Storage Temperature Range:
-40 to 60°C (-40 to 140°F)
Operating and Storage Humidity:
0 to 85% maximum RH
(non-condensing)
Altitude: Up to 2000 m (1.24 mi)
Mounting Requirements
Maximum panel thickness is 9.5 mm
(0.375") Min panel thickness for NEMA
4 (IP65) sealing is 1.57 mm (0.060")
Connections: All wiring connections
are made to the module via high
compression cage-clamp terminal
blocks. Wiring instructions are provided.
Construction: Steel front panel,
enclosure, and rear cover with textured
black polyurethane paint for scratch
and corrosion resistance protection.
Sealed front panel meets NEMA 4
(IP65) specifications for indoor use
when properly installed. Installation
Category II, Pollution Degree II.
Panel gasket and keps nuts included.
Weight: 1.2 kg (2.7 lb) (less module
Option Boards
Specifications
RS485 Communication Card:
(LDP6-CDC10 or LDP6-CDC1C)
Type: RS485 multi-point
balanced interface
Isolation to Sensor and User
Input Commons: 500 Vrms for
1 minimum
Working Voltage: 50V not isolated
from all other commons
Baud Rate: 300 to 19.2k
Data Format: 7/8 bits; odd, even,
or no parity
Bus Address: 0 to 99, maximum
32 meters per line
Transmit Delay: Selectable
2 to 50 msec or 50 to 100 msec
Type: RS232 half duplex
Isolation to Sensor and User
Input Commons: 500 Vrms for 1 min
Working Voltage: 50V not Isolated
from all other commons
Baud Rate: 300 to 19.2k
Data Format: 7/8 bits; odd, even
or no parity
Modbus® Communications Card
(LDP6-CDC40 or LDP6-CDC4C)
Type: RS485; RTU and ASCII
MODBUS modes
Isolation to Sensor and User Input
Commons: 500 Vrms for 1 minute
Working Voltage: 50V not isolated
from all other commons
Baud Rates: 300 to 38400
Data: 7/8 bits
Parity: No, odd, or even
Addresses: 1 to 247
Analog Output Card (LDP6-CDL
Types: 0 to 20 mA, 4 to 20 mA and
0 to 10 Vdc
Isolation to Sensor and User Input
Commons: 500 Vrms for 1 minimum
Working Voltage: 50V not isolated
from all other commons
Accuracy: 0.17% of FS (18 to 28°C);
0.4% of FS (0 to 50°C)
Resolution: 1/3500
Compliance:
10 Vdc: 10 kΩ load minimum
20 mA: 500 Ω load maximum
Update Time: 200 msec maximum
to within 99% of final readout value
(digital filter and internal zero correction
disabled) 700 msec max (digital filter
disabled, internal zero correction
enabled)
LDP63000-AC: 1 sec maximum to
within 99% of final readout value (digital
filter disabled)
Setpoint Output Cards (Four
Types of Field Installable Cards)
Response Time: 200 msec maximum
to within 99% of final readout value
(digital filter and internal zero correction
disabled) 700 msec maximum (digital
filter disabled, internal zero
correction enabled)
LDP63000-AC Only: 1s maximum to
within 99% of final readout value (digital
filter disabled)
LDP63000-T Only: 200 msec typ.;
700 msec maximum (digital
filter disabled)
Dual Relay Card (LDP6-CDS10)
Type: Two Form C (SPDT) relays
Isolation to Sensor and User Input
Commons: 2000 Vrms for 1 minimum
Working Voltage: 250V
M-X
Contact Rating:
One Relay Energized: 5 A @
120/240 Vac or 28 Vdc (resistive
load), 1⁄8 HP @120 Vac, inductive
load total current with both relays
energized not to exceed 5 A
Life Expectancy: 100k cycles min at
full load rating. External RC snubber
extends relay life for operation with
inductive loads.
Quad Relay Card (LDP6-CDS20)
Type: Four Form A (SPST) relays
Isolation to Sensor and User Input
Commons: 2300 Vrms for 1 minimum
Working Voltage: 250 Vrms
Contact Rating:
One Relay Energized: 3 A @
250 Vac or 30 Vdc (resistive load),
1
⁄10 HP @120 Vac, inductive load total
current with all four relays energized
not to exceed 4 A
Life Expectancy: 100k cycles min at
full load rating. External RC snubber
extends relay life for operation with
inductive loads.
Quad Sinking Open
Collector (LDP6-CDS30)
Type: Four isolated sinking
NPN transistors
Isolation to Sensor and User
Input Commons: 500 Vrms for 1 min
Working Voltage: 50V not isolated
from all other commons
Rating: 100 mA maximum @
Vsat = 0.7V maximum Vmax = 30V
Quad Sourcing Open
Collector (LDP6-CDS40)
Type: Four isolated sourcing
PNP transistors
Isolation to Sensor and User
Input Commons: 500 Vrms for 1 min
Working Voltage: 50V not isolated
from all other commons
Rating:
Internal Supply: 24 Vdc ± 10%,
30 mA maximum total all four
External Supply: 30 Vdc maximum,
100 mA maximum each output
Programming Software
(Free download at omega.com/
dp6soft). Allows configuration of the
LDPF63000 meter from a PC. This
software offers standard drop-down
menu commands, that make it easy to
program the meter. The unit program
can then be saved in a PC file for future
use. A serial plug-in card is required to
program the meter using the software.
7.2
(0.285)
89.90
(3.54)
120.7
(4.75)
254
(10)
7.2
(0.285)
89.90
(3.54)
106.7
(4.2)
3.05
120.7
(0.12)
(4.75)
118.10
(4.65)
+1.01
-0.00
+0.04
0.00
2.0
(0.08)
92.2 +0.78
-0.00
(3.63)+0.03
0.00
106.7
2x 120
89.90
(4.725)
(3.54) (4.2)
9
(3
5.94 (0.234) Dia.
Thru, Typical
254
(10)
92.2
236 +1.01
-0.00
(9.29)+0.04
0.00
3.05
(0.12)
+0.78
-0.00
(3.63)+0.03
0.00
2.0
(0.08)
7.2
236
(0.285)
(9.29)
106.7
(4.2)
118.10
(4.65)
5.94 (0.234)
Thru, Typi
2x 120
(4.725)
118.10
(4.65)
2.0
(0.08)
Dimensions: mm (inch)
To Order
Model No.
LDPF63000
Description (Display Meter Only, No Outputs)
Large display meter, digital inputs, 85 to 250 Vac power
Optional Plug-in Output Cards (Field Installable)
Model No.
Description
Optional
Plug-in
Output
Cards
(Field
Setpoint Alarms (Only 1 Alarm
CardInstallable)
Can Be Installed Into Base Meter)
LDP6-CDS10
Dual setpoint relay output card
LDP6-CDS20
Quad setpoint relay output card
LDP6-CDS30
Quad setpoint sinking open collector output card
LDP6-CDS40
Quad setpoint sourcing open collector output card
Analog Output
LDP6-CDL10
Analog output card
Communications (Only 1 Communications Card Can Be Installed Into Base Meter)
LDP6-CDC10
RS485 serial communications output card with terminal block
LDP6-CDC1C
Extended RS485 serial communications output card with dual RJ11 connector
LDP6-CDC20
RS232 serial communications output card with terminal block
LDP6-CDC2C
Extended RS232 serial communications output card with 9-pin D connector
LDP6-CDC40
Modbus® communications card
LDP6-CDC4C
Extended Modbus communications card with dual RJ11 connector
M
Accessories (Field Installable)
Model No.
Description
LDP6-PGM
Remote programming module with 3 m (10') cable
LDP6-ENC12
NEMA 4 (IP65) enclosure
LDP631-SHR
Shroud cover for high intensity light environments
LDP6-EN/SH
NEMA 4 (IP65) enclosure with shroud
Sofware is free. Download from omega.com/dp6soft
Comes complete with operator’s manual.
Note: Adding option cards—meters can be fitted with up to 3 optional plug-in cards, however, only 1 card from each function type can be
installed at a time. The function types include setpoint alarms, analog output and communications. The cards can be installed initially or at a
later date. Each optional plug-in card is shipped with installation and programming instructions.
Ordering Example: LDPF63000, large display meter, digital inputs, 85 to 250 Vac power, and LDP6-CDL10 analog output card.