UEC1P5-X
UEC1P5-X
6A three phase 3 or 4 wire programmable energy meter
•
For 1 or 5A CT
•
Programmable CT ratio
•
Fully bi-directional 4-quadrant measurements for all
energies and powers
•
For 3 / 4 wire networks with balanced or unbalanced load
•
Class B according to EN 50470-3 (MID)
•
Tariff input
•
2 S0 outputs for energy pulse emission
•
LCD display with 8 main digits
•
IR optical port for communication with external modules
•
Available with MID certification
» General features
4 DIN modules energy meter for the energy measurement in industrial and civilian application, available with MID
certification suitable for billing. Combined with different external modules, the meter can communicate with other
systems. COM modules are available for the most common field protocols.
Besides the energy, the meter can measure the main electrical parameters and makes them available on the IR port.
The LCD display shows the energies and the instantaneous powers.
The meter is built according to EN 50470-1 standard. The active energy is compliant to IEC/EN 62053-21 class 1, but
for MID certified device it moreover fulfills class B requirements according to EN 50470-3. The accuracy of reactive
energy is compliant to IEC/EN 62053-23 class 2.
Wide backlighted LCD display with clear graphic symbols comprehensible at a glance. Metrological LED on front
panel and sealable terminal covers. Available versions with different voltage working range for the connection on 3
or 4 wire network, suitable for balanced or unbalanced loads. The analysis of the MTBF values, the accurate selection
of components and the reduction of the internal working temperatures together with strict production and control
standards guarantee a product with an excellent quality and a long lasting reliability.
» Applications
» Benefits
•
•
•
•
•
•
•
•
•
Totalization of the electric energy in the industry for
each single line or machine.
Measurement of energy generated by renewable
sources such as solar, eolic, etc.
Accounting and billing of consumptions in camp sites,
malls, residential areas, naval ports, etc.
Totalization of the electric consumption in hotels,
congress centers, exhibition fairs.
Accounting of the consumptions in buildings with
executive office services.
Internal allocation of the consumptions in timeshare
civilian and industrial buildings.
Realization of energy monitoring systems.
Remote survey of the consumptions and compute
of the costs.
•
•
•
Up to 30 instantaneous measurements, complete set
of energy counters with 2 tariffs total and partial
counters. Moreover partial counters can be started,
stopped or reset.
Suitable for CT with 1 or 5A secondary. CT ratio is
programmable (1 ... 10000).
Phase sequence and diagnostic function for error
signalling in case of wrong polarity connection.
Available MID according to Swiss market (MID S).
Reactive energy is not shown on energy meter display.
» Related products
•
Communication modules
(RS485 Modbus, M-Bus, Lan gateway, KNX)
1
Innovative Electronic Systems
Mid Energy Meters
Mid Energy Meters
Mid Energy Meters
UEC1P5-X
» Technical features
Power supply
•
•
•
•
•
S0 outputs
Power supplied from the voltage circuit
Nominal measurement voltage ±20%
Max consumption (for each phase): 7.5 VA - 0.5 W
CT burden (for each phase): 0.04 VA
Nominal frequency: 50/60 Hz
•
•
•
Voltage & frequency
•
Nominal values:
A) 3x230/400 V 50 Hz
D) 3x230/400 ... 3x240/415 V 50/60 Hz
The measuring unit (imp/kWh, imp/kvarh, imp/kVAh) changes
according to the assigned counter (kWh, kvarh, kVAh)
•
Current
•
•
•
•
•
•
•
•
2 passive optoisolated
Maximum values: 250 VAC-DC - 100 mA
Meter constant according to the set CT ratio:
1000 imp/kWh with CT ratio in range 1...4
200 imp/kWh with CT ratio in range 5...24
40 imp/kWh with CT ratio in range 25...124
8 imp/kWh with CT ratio in range 125...624
1 imp/kWh with CT ratio in range 625...3124
0.1 imp/kWh with CT ratio in range 3125...10000
Starting current Ist: 2 mA
Minimum current Imin: 10 mA
Transitional current Itr: 50 mA
Reference current Iref (In): 1 A
Maximum current Imax: 6 A
•
•
Accuracy
•
•
Pulse length: 50 ±2ms
Tariff input
Active optoisolated
Voltage range for tariff 2: 80 ... 276 VAC-DC
Metrological LED
Active energy class 1 according to IEC/EN 62053-21 (NO MID)
Active energy class B according to EN 50470-3 (MID)
Reactive energy class 2 according to IEC/EN 62053-23
Meter constant: 10000 imp/kWh
Pulse length: 10 ±2ms
Environmental conditions
•
•
•
•
Operating temperature: -25°C ... +55°C
Storage temperature: -25°C ... +75°C
Humidity: 80% max without condensation
Protection degree: IP51 frontal part -IP20 terminals
» Technical drawing (mm)
90
45
72
44
64
2
Innovative Electronic Systems
Mid Energy Meters
UEC1P5-X
» Measurements
SYMBOL
3 WIRE 4 WIRE
COM
MEASURE UNIT,
DISPLAY
PORT
value or status SYSTEM SYSTEM
Phase voltage
VL1-N -VL2-N -VL3-N
V
Line voltage
VL1-L2 - VL2-L3 - VL3-L1 V
System voltage
V∑
V
Phase current
I1 - I2 - I3
A
Neutral current
IN
A
System current
I∑
A
Phase power factor
PFL1 - PFL2 - PFL3
-
System power factor
PF∑
-
Phase apparent power
SL1 - SL2 - SL3
VA
System apparent power
S∑
VA
Phase active power
PL1 - PL2 - PL3
W
System active power
P∑
W
Phase reactive power
QL1 - QL2 - QL3
var
System reactive power
Q∑
var

Frequency
f
Hz


Phase sequence
CW/CCW
-




Power direction
>
<
-




Phase active energy
L1 - L2 - L3
Wh



System active energy
∑
Wh



Phase inductive and capacitive reactive energy
L1 - L2 - L3
varh

v

System inductive and capacitive reactive energy
∑
varh

v

Phase inductive and capacitive apparent energy
L1 - L2 - L3
VAh



System inductive and capacitive apparent energy
∑
VAh



Tariff 1/2 phase active energy
L1 - L2 - L3
Wh



Tariff 1/2 system active energy
∑
Wh



Tariff 1/2 phase inductive and capacitive reactive energy
L1 - L2 - L3
varh

v

Tariff 1/2 system inductive and capacitive reactive energy
∑
varh

v

Tariff 1/2 phase inductive and capacitive apparent energy
L1 - L2 - L3
VAh



Tariff 1/2 system inductive and capacitive apparent energy
∑
VAh




Resettable partial energy counters
∑
Wh, varh, VAh


v

Energy balance
∑
Wh, varh, VAh


v

Present tariff
T
1/2
Secondary values
SEC
ON/OFF


CT ratio
CT
Set value


Undervoltage/overvoltage
VOL, VUL
ON/OFF

Undercurrent/overcurrent
IOL, IUL
ON/OFF

Frequency out of range
fout
ON/OFF

Partial counters
PAR
S0 output status
1
INSTANTANEOUS VALUES










































RECORDED DATA





OTHER INFORMATION
LEGEND:
 = Available
 = Bidirectional value
2

START/STOP

Active


v = varh not available for MID S meter
3
Innovative Electronic Systems
Mid Energy Meters
UEC1P5-X
ORDER
CO D E
VOLTAGE and
freqUENCY INPUT
COMMUNICATION
PORT
Self-powered
IR
UEC1P5-A
1102.0001.0001
3x230/400V 50Hz
1102.0002.0001
3x230/400V 50Hz
1102.0003.0001
3x230/400V 50Hz
1102.0004.0001
3x230/400V 50Hz
1102.0005.0001
3x230/400V 50Hz
1102.0006.0001
3x230/400V 50Hz
1102.0007.0001
3x230/400V 50Hz
1102.0008.0001
3x230/400V 50Hz
1102.0009.0001
3x230/400V 50Hz
1102.0010.0001
3x230/400V 50Hz
1102.0011.0001
3x230/400V 50Hz
1102.0012.0001
3x230/400V 50Hz
•
•
•
•
•
•
•
•
•
•
•
•
UEC1P5-D
1102.0013.0001
3x230/400V...3x240/415V 50/60Hz
1102.0014.0001
3x230/400V...3x240/415V 50/60Hz
1102.0015.0001
3x230/400V...3x240/415V 50/60Hz
1102.0016.0001
3x230/400V...3x240/415V 50/60Hz
1102.0017.0001
3x230/400V...3x240/415V 50/60Hz
1102.0018.0001
3x230/400V...3x240/415V 50/60Hz
1102.0019.0001
3x230/400V...3x240/415V 50/60Hz
1102.0020.0001
3x230/400V...3x240/415V 50/60Hz
1102.0021.0001
3x230/400V...3x240/415V 50/60Hz
1102.0022.0001
3x230/400V...3x240/415V 50/60Hz
1102.0023.0001
3x230/400V...3x240/415V 50/60Hz
1102.0024.0001
3x230/400V...3x240/415V 50/60Hz
LEGEND
IR:
MID:
MID S:
NONE:
RESET:
•
•
•
•
•
•
•
•
•
•
•
•
OPTIONS
MID MID S
•
•
•
•
•
•
•
•
•
•
•
•
NONE
•
•
•
•
•
•
USER MANUAL
LANGUAGES
RESET
IT/EN
•
•
•
•
•
•
DE/EN FR/EN
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
IR port. This port allows to combine the meter with the communication module (not included).
MID certified meter, with reset function only on partial counters.
MID certified meter, with reset function only on partial counters, without reactive energy counters on display (only SWITZERLAND
Meter without MID certification, with reset function only on partial counters.
Meter without MID certification, with RESET function on ALL counters.
NOTE: Subject to change without notice
Innovative Electronic Systems
Via Passerina, 3/A - 28010 Fontaneto d’Agogna (NO) - Italy - Tel.: +39 0322 89307
sales@algodue.it - www.algodue.com
72PG01_2_201705_1
).
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising