GE DCCB330 Installation instructions


Add to my manuals

advertisement

GE DCCB330 Installation instructions | Manualzz

DCCD330GG

GE ® Super 7.0 Cu. Ft. Capacity Coin-Operated Gas Dryer

Dimensions and Installation Information (in inches)

Exhaust Options:

Shipped with exhaust to the rear.

When viewed from the front of the unit, exhaust 3-way via left, bottom and rear. Maximum recommended exhaust duct length is 15 feet of 4" rigid ducting with two 90° elbows and dampered wall cap.

(See Installation Instructions)

Gas – An individual branch circuit fused for 15- or 20-amp is required for each dryer.

Gas Dryer Rating:

120V, 60Hz

Gas (BTU/HR):

20,000. Factory equipped for natural gas. Tested for LP gas. A conversion kit is required for LP gas.

Check installation instructions for correct kit number. Have a qualified technician install the conversion kit. Equipped with energy saving Glo-Bar ignition.

Dryer Note:

Dryer wall outlet must be located within 36" of service cord entry and accessible when dryer is mounted in position.

Installation Information:

For complete installation information see installation instructions packed with product.

42

36

25-1/2

DCCB330 QS

6/16/03 km

27

For answers to your Monogram, ® GE Profile ™ or

GE ® appliance questions, visit our website at ge.com or call GE Answer Center ® service,

800.626.2000.

Specification Revised 5/09 370402

DCCD330GG

GE ® Super 7.0 Cu. Ft. Capacity Coin-Operated Gas Dryer

Dimensions and Installation Information (in inches)

For complete information, see installation instructions packed with your dryer.

Ducting Materials:

For best performance, this dryer should be vented with 4" diameter all-rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). In special installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter can be maintained throughout the entire length of the transition duct. Please see installation instruction packed with your dryer for complete instructions when using flexible metal

(foil type) ducting.

Exhaust Length Calculation:

1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.

2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table.

2. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.

Special Installation Requirements

Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label

on the dryer back.

• The dryer MUST be exhausted to the outside.

• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

0" either side

3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.

• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.

Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors. See installation instructions.

• The installation must conform with the local codes, or in the absence of local codes, with the

National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

• Minimum clearances to combustible surfaces

0" both sides

3" rear

Dryer Exhausting Information – Use Metal Duct Only

Vertical and Horizontal Ducting

Dryers must be exhausted to the outside.

Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.

Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down.

A

4

B

A

Domestic dryer models

2-1/2

7.0, 6.0 and 5.8 cu. ft.

capacity models all electric dryers

Number of

90° turns

0

1

2

3

4

Best performance

Maximum length of 4" dia. rigid metal duct

Exhaust hood type

A

4" opening

90 ft.

60 ft.

45 ft.

35 ft.

25 ft.

B

2-1/2" opening

60 ft.

45 ft.

35 ft.

25 ft.

15 ft.

For answers to your Monogram, ® GE Profile ™ or

GE ® appliance questions, visit our website at ge.com or call GE Answer Center ® service,

800.626.2000.

Specification Revised 5/09 370402

DCCD330GG

GE ® Super 7.0 Cu. Ft. Capacity Coin-Operated Gas Dryer

Dimensions and Installation Information (in inches)

Features and Benefits

• Auto Dry – Uses thermostats to monitor air temperature and reduce fabric wear

• Pushbutton Controls – Simplifies cycle selection

• LED Readout – Provides accurate wash times, from fill to finish

• Painted Drum – Painted drum coated with a rustproof finish to stand up to heavy use

• Three Heat Selections – Offers enhanced drying performance and fabric care

• Three Dry Cycles – Offer quick, easy options for drying and caring for clothes

• Reverse-A-Door – Offers added installation flexibility

• Model DCCD330GGWC – White

For answers to your Monogram, ® GE Profile ™ or

GE ® appliance questions, visit our website at ge.com or call GE Answer Center ® service,

800.626.2000.

Specification Revised 5/09 370402

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement