GE DPSE810GGWT Installation instructions


Add to my manuals

advertisement

GE DPSE810GGWT Installation instructions | Manualzz

25-1/2

27

42

51

36

Side View Rear View

DPSE810GG

GE Profile ™ 7.0 Cu. Ft. Super Capacity Gas Dryer with Stainless Steel Drum

23-1/2 28-1/4 *24-1/2" from the edge of the side panel to the front.

25-1/2" from front to edge of endcaps.

Dimensions and Installation Information (in inches)

Exhaust Option: When viewed from the front of the unit, exhaust 3-way via rear, left and bottom. Dryer is shipped exhausted to the rear. Alternate exhausting knockouts are supplied.

Gas: An individual, properly-grounded branch circuit, with a three-prong groundingtype receptacle, protected by a 15 or 20 amp circuit breaker or a time-delay fuse is required.

Gas Dryer Electric Rating: 120V, 60Hz, 6A

Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply requires a conversion kit. Check installation instructions for correct kit and have a qualified gas technician install a conversion kit. See dryer ducting information for proper installation.

5.7 cu. ft. Dryers

2

36" of service cord entry and accessible when dryer is mounted in position.

Installation Information: For complete information, see installation instructions packed with your dryer.

Power

Cord Hole

30-1/2

For answers to your Monogram, ® GE Profile ™ or

GE ® appliance questions, visit our website at ge.com or call GE Answer Center ® service,

800.626.2000.

Back View

Washer/Dryers SC QSart

Power

Cord Hole

Back View

25-1/2*

8-1/2

Side View

5

4-1/2

36

42

2-1/2

11-1/2

2

27

3-1/2

Rear View

Listed by

Underwriters

Laboratories

Specification Revised 9/07 270191

DPSE810GG

GE Profile ™ 7.0 Cu. Ft. Super Capacity Gas Dryer with Stainless Steel Drum

For complete information, see installation instructions packed with your dryer.

Ducting Materials:

For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If “all rigid metal” duct cannot be used, then “flexible all metal” venting can be used, but it will reduce the maximum recommended duct length.

Exhaust Length Calculation:

1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.

2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. The maximum length for flexible ducts are less than for rigid duct. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.

Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside.

Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.

Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down.

Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4" opening dampered wall cap.

For more information on venting kits and accessories, please call 1-800-GE-CARES.

Special Installation Requirements

Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label

on the dryer back.

• The dryer MUST be exhausted to the outside.

• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

0" either side; 3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.

• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.

Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

• The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.

Minimum Clearances other than Alcove or Closet Installation:

• Minimum clearances to combustible surfaces are: 0" both sides; 3" rear

Dryer Exhausting Information: Use metal duct only, vertical and horizontal ducting.

Specification Revised 9/07 270191

DPSE810GG

GE Profile ™ 7.0 Cu. Ft. Super Capacity Gas Dryer with Stainless Steel Drum

Features and Benefits

• 7.0 cu. ft. Super Capacity - Large enough to handle anything the washer sends its way

• Stainless Steel Drum - Resists rust and won't chip, peel or snag clothes

• Five Heat Selections - Temperatures are matched to fabric type for better fabric care

• 20 Dry Cycles - Clothes are easily matched to fabric type for optimal drying performance and flexibilty

• Sensor Dry Plus - Continually monitors moisture levels to help clothes look better longer

• On/Off End-of-Cycle Signal - Can be turned on so you can hear it from another room, or turned off when you don't want to disturb others

• Interior Dryer Light - Lets you see everything inside for easy loading and unloading

• Rotary Electronic Controls with Cycle Countdown Display and LED

Indicators - Simplify the cycle selection and provide accurate cycle times

• Delicate Cycle with Extra-Low Heat Setting - Maintains an average fabric temperature of 125 degrees F to protect fine handwashables

• Model DPSE810GGWT –Titanium on white

DPSE810EG.EPS

Specification Revised 9/07 270191