Audio Door Stations 30
C
o
n
t
ROOM
1 2
DOOR
DOOR
ROOM
2 3
DOOR
ROOM
1 1
DOOR
ROOM
1 3
DOOR
ROOM
3 5
MASTER
Wide and Zoom & PanTilt Hands-free Video Intercom
JK-1MD/JK-1MED
1
DOOR
Hands-free Color Video Intercom
JF-1MD
5
Hands-free Color Video Intercom, Picture Memory
JF-2MED
7
Hands-free Color Video Intercom, PanTilt, Picture Memory
JA-2MECD
9
KCS-1ARD
11
Video Sentry Color Tilt
KC-1GRD
13
Video Sentry Color Tilt
KB-3MRD
15
Chime Tone Intercom
C-123L/A
24
Chime Tone Intercom
TCS-MH
25
Chime Tone Intercom
IE-1AD(U)
26
Chime Tone Intercom
IE-1GD(U)
27
ROOM
2 3
DOOR
23
ROOM
1 3
DOOR
DA-1AS
ROOM
1 1
DOOR
Video Sentry Color Tilt
ROOM
1 1
DOOR
Two-Wire Electric Lock Door Phone
Chime Tone Intercom
IE-2A2DU
28
ROOM
2 6
Chime Tone Intercom
IE-8MD
29
Audio Door Stations
30
Integratable Audio / Video Security
17
ROOM
1 3
DOOR
s
ROOM
1 1
DOOR
8 120 AX
DOOR
t
ROOM
1 1
DOOR
ROOM
2 3
DOOR
DOOR
ROOM
1 1
n
AUDIO ENTRY SECURITY
VIDEO ENTRY SECURITY
DOOR
e
Wide Angle Video Sentry
MK-1GD
19
MULTI-UNIT ENTRY SECURITY
Hands-free Color Video Bus Apartment System
ROOM
2 3
PanTilt Video Sentry
MK-2MCD
GH SYSTEM
20
31~44
31
System outline
Video Accessories
ENTRANCE RESIDENCE
KC-32EU, JBW-BA, RY-3DL
KAW-D, MCW-S, MK-2DA, MK-2DG, MYW-BA
21
22
33
5 48 Standard System configuration
ENTRANCE RESIDENCE
16 500 Expanded System configuration
Entrance station
Residential station
Security guard station, Control unit
GH lift control adaptor
GH CCTV camera interface adaptor for Reception
Cabling (standard)
Wiring (standard)
34
35
38
39
41
42
43
44
Bus Apartment System
45~55
GF SYSTEM
ENTRANCE
RESIDENCE
Two-Wire Bus System
5 100 or 250 GF Audio
ENTRANCE
45
RESIDENCE
Four-Wire Common B&W Video System
5 100 or 250 GF Audio/Video
47
GF Components
ENTRANCE RESIDENCE
Example
2
SINGLE-FAMILY HOME
DOOR
ENTRANCE
MASTER
SERVICE SIDE
STATION
3
MULTI-TENANT
ROOM
RESIDENCE
SUB
PUBLIC SIDE
1 4
ENTRANCE RESIDENCE
49
Two-Wire Electric Lock Door Phone
DA-4DS
54
Audio Entry Security
1 58 VC-M
COMMERCIAL BUILDING
FACTORY
55
OFFICE
SCHOOL
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
DOOR
ROOM
1 1
MASTER
Open Voice Intercom
LEM-1DL
57
VIDEO ENTRY SECURITY
SUB
1 3
Open Voice Intercom
LEM
58
STATION
Open Voice Intercom
11
DOOR
LEF
59
ROOM
3 8
Open Voice Intercom
LEF-C
61
Handset Intercom
LE Sub stations & Accessories
MASTER
SUB
1 3
STATION
Handset Intercom
AT-406
YAZ-90-3W
STATION
64
AUDIO ENTRY SECURITY
Handset Intercom
25
TD-H/B lTD-Z/A
DOOR
65
Integratable Audio / Video Security
8 120 AX
MASTER
63
Handset Intercom
90
MASTER
62
67
SUB
Commercial Security Intercom
64 1,024 AI-900
SERVICE PUBLIC
1 1
MASTER
SUB
IMU-100
SUB
ROOM
10 1
STATION
SUB
SUB
SUB
82
83
High-Power Intercom
84
Nurse Call
1 80 NHX
MASTER
81
Mid-Power Intercom
MP-S
2 10 AP-M
MASTER
79
Master / Sub Intercom
TC-M & TB-AD10
MC-60/4A
SUB
1 3
MASTER
MULTI-UNIT ENTRY SECURITY
Market-Com
60
MASTER
77
Master / Sub Intercom
2 100 TC-M
DOOR
75
Master / Sub Intercom
1 120 NEM
MASTER
71
Security Window Intercom
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
85
Nurse Call
1 120 NEM
91
ACCESS CONTROL, ACCESSORIES & POWER SUPPLIES
Access Control
AC-10S, AC-10F
95
Accessories
IER-2, EL-12S, RY-PA, RY-AC/A
TAR-3, MAW-B
Power Supplies
97
98
99
ACCESS CONTROL, ACCESSORIES & POWER SUPPLIES
COMMUNICATION DISTANCE & INDEX
Communication Distance
Compatibility of video intercom system
Index
101
102
103
COMMUNICATION DISTANCE & INDEX
Communication Systems for business, home and industry
Established In 1948
Aiphone has become the most respected and reliable brand of communication systems in the world.
With headquarters in Nagoya and manufacturing in Toyota City, Central Japan, we export to over 60
countries. We expand ourselves along with a North American marketing, sales and distribution center
near Seattle, Washington, and an European sales and distribution center in Lisses-Evry, France.
Systems For Every Application
Aiphone products range from simple do-it-yourself door answering units to sophisticated video entry security
systems, complex microprocessor-based commercial systems, and luxury condo/apartment
security/communication systems. They are unrivaled in design simplicity, technical excellence and reliability.
With over 30 standard systems, and additional manufacturing by special order, we can create a system for
virtually any intercom application.
Designed To Last
Every Aiphone system is the result of painstaking attention to detail: contemporary European style design,
the finest quality hardware and circuitry, engineered, built and 100% pre-tested for sustained trouble-free service.
AIPHONE CO., LTD.
in Japan Headquarters
Toyota factory
IS0 9001
Aiphone is the first intercom manufacturer worldwide to receive ISO 9001 certification, and
the only one selling in North America, An agency representing the International Standards
Organization (ISO), headquartered in Geneva, Switzerland, graded Aiphone against guidelines
for design and development, production, and product inspection and testing. ISO 9001
standards provide an immediate recognition of product quality almost anywhere in the world.
ISO 9001 Certified
JQA-0291
AIPHONE CO., LTD.
Winner Of The Deming Prize
Aiphone is the first and only intercom manufacturer to win the Deming Prize, the highest
international award for quality control. Named in honor of Dr. W. Edwards Deming, the
award honors firms worldwide which advance and maintain manufacturing quality.
Deming Prize
Acquisition of IS0 14001
ISO's Environmental Standards are a series of voluntary standards and guideline reference
documents which include environmental management systems, eco-labeling, environmental
auditing, life cycle assessment, environmental performance evaluation, and environmental
aspects in products standards. In early 1998, our management team determined to acquire
ISO-14001 approval as a company-wide project, and working committee was established at
the same time. Since then, with our ongoing efforts and practice about environmental
management standards, we have succeeded to acquire the approval.
Aiphone excludes the use of prohibited material from the product according to RoHS
directive (2002/95/EC). Therefore, as of July 1, 2006, all the Aiphone products imported in
EU will be fully complied with the RoHS directive.
AIPHONE CORPORATION
in USA
AIPHONE S.A.S.
in France
ISO 14001 Certified
JQA-EM0453
Headquarters section
Toyota Factory
Taiho Site
AIPHONE CO., LTD.
ENVIRONMENTAL REPORT
We will contribute to building a sustainable society while cultivating
communications with a wide spectrum of our stakeholders.
Basic Environmental Philosophy
Revised October 1, 2005
Based on our business philosophy of "Be Responsible for your job and don't cause of problems
for others," we carry out our activities while harmonizing conservation of the global environment
with our business operations.
Environmental Policy
The AIPHONE group aspires to be enterprises capable of making contributions to society by using
communication and security technologies, conducting our environmental activities as follows:
(1) We will strive to minimize environmental loads to conserve the global environment in our activities of developing,
producing, selling, and servicing our products.
(2) We will make our goals and objectives clear in our business activities, continuously evaluating the following items
and thus improving them:
a) We will aim to become a recycling society and make efforts to promote the 3R's (Reduce, Reuse, and Recycle)
and minimize waste.
b) We will not use harmful substances that cause environmental contamination.
c) We will strive to conserve energy to prevent global warming.
(3) We will conform to environment-related laws, regulations, and conventions while establishing voluntary standards to
conserve the environment.
(4) Placing great value on communication, we will promote the manufacture of products friendly to both humans and the
environment.
(5) We will conduct environmental audits in an effort to maintain and improve our environment management system.
(6) We will make our environmental policy thoroughly known to our employees and all those who work together with us.
(7) We will publicize this environmental policy to the general public.
Certificate of acquisition of
lSO 14001 accreditation
This report is also posted on our website:
http://www.aiphone.co.jp/english/
Available 2 nd Quarter 2009
Wide and Zoom & PanTilt Hands-free Color Video Intercom
JK-1MED / JK-1MD
JK Series
P.1
Only 27mm
Innovative Wide and Zoom & PanTilt camera
control functions are both integrated
in JK new color video intercom system!
DOOR
ROOM
1
2
Picture
memory
Standard
Non-Picture
memory
or
JK-DA
Wide and Zoom & PanTilt
Standard video station
JK-1MED
Master station w/Wide and Zoom & PanTilt
color monitor & Built-in picture memory
JK-1MD
Master station w/Wide and
Zoom & PanTilt color monitor
or
Vandal - resistant door stations
Sub master stations
or
JK-DV
Wide and Zoom & PanTilt
Vandal-resistant video
door station, surface mount
or
JK-DVF
Wide and Zoom & PanTilt
Vandal-resistant video
door station, flush mount
JK-1HD
Sub master station
w/Wide and Zoom & PanTilt
color monitor
The JK is color video entry system providing largely wide field of vision by its
innovative Wide and Zoom & PanTilt camera control. Supports up to one door
station and two inside stations. Choice of two master stations; JK-1MD
(standard) or JK-1MED (w/built-in picture memory) and three of door
stations: JK-DA (standard surface mount plastic panel), JK-DV (Vandalresistant surface mount panel) or JK-DVF (Vandal-resistant flush mount
panel).
JK-1SD
Audio sub master station
Wide and Zoom & PanTilt Hands-free Color Video Intercom
Features
DOOR
ROOM
1
2 JK-1MD/JK-1MED
Door station
• One door & two monitors (3-1/2 inch); room to room
communication is available
• Streamlined & Thin design, only 27 mm thickness
• Vandal resistant video door stations are available
• Optional audio sub master station (JK-1SD)
• Total hands-free communication, auto-voice actuation
Master station
Standard
VIDEO ENTRY SECURITY
Non-Picture
memory
4
2
2
2
IER-2
Call extension
m P.97
PT
JK-DV
PS18
Wide and Zoom & PanTilt Vandal-resistant video
door station, surface mount
JK-1MD
Master station w/Wide and
Zoom & PanTilt color monitor
or
or
Picture
memory
or
JK-DA
JK-DVF
PS18
Wide and Zoom & PanTilt
video door station, surface mount
Wide and Zoom & PanTilt
Vandal-resistant video
door station flush mount
JK-1MED
Power supply PS-1820S PS-1820UL PS-1820 m P.100
Communication network
Master station w/Wide and
Zoom & PanTilt color monitor
& built-in picture memory.
PANORAMIC WIDE View
Everyone at the entrance can be identified by image from JK wide angle camera.
The field of vision can be controled on WIDE mode or ZOOM mode from inside.
(Master station)
or
JK-1MD
JK-1MED
JK-DV
WIDE IMAGE
M
ZOOM IMAGE
Zoom & PanTilt
By pressing PanTilt button, the image of the PanTilt video door station can be adjusted to
a more visible position from inside on the zoom mode.
or
JK-1SD
JK-1HD
(Sub master station)
The design and specifications are subject to
change without notice for improvement.
1
*The screen images are simulated graphics. They are images to express functions, and
are different from the real one. Please understand it beforehand.
Available 2 nd Quarter 2009
•
•
•
•
•
•
• Talk LED lights in red while speaking
• Visual monitoring with audio for 1 minute
• Built-in picture memory; Record visitor both automatically & manually
(JK-1MED only)
• Instant voice call-in with image
• Press-to-talk operation available
• Press-to-talk restriction
• White LED illumination turns on in low-light conditions
Backlight compensation by "ADJUST" button
Full color video in low light situations w/o external illumination
PanTilt and Zoom & Wide camera control
Camera angle preset
External input
Option - Option button, press-to-talk setting, video signal output
Lineup
Sub master station
Long distance adaptor
m P.4
*Max. 300m away from
Master/sub to Door.
JK-1HD
Sub master station
w/color monitor
Electric door strike
m P.97
4
or
JK-1SD
Audio sub master
station
VIDEO ENTRY SECURITY
EL-12S
JKW-BA
Access Contorol m P.95
AC-10S
Boxed sets
Access control
keypad,
surface mount
Standard
JKS-1AD: JK-1MD, JK-DA
JKS-1ADV: JK-1MD, JK-DV
JKS-1ADF: JK-1MD, JK-DVF
Picture memory
AC-10F
JKS-1AED: JK-1MED, JK-DA
JKS-1AEDV: JK-1MED, JK-DV
JKS-1AEDVF: JK-1MED, JK-DVF
Access control
keypad,
flush mount
JK-DV + AC-10S
Add appropariate power supply
Unit dimensions
Specifications
185
135
27
80
JK-DA
8
120
209
97
88
35.5
Video monitor
Scanning line
Video output
Night viewing
29
Door release
Option output
Wiring
61
AC-10F
98
33
Wiring distance
18V DC
PS-1820S, PS-1820UL, PS-1820
Max. 400mA (JF-1MED, JK-1MD). Max. 200mA (JK-1HD).
Max. 120mA (JK-1SD)
Chime. Image & audio, approx. 45 sec.
Approx. 1 min.
AUTOMATIC (Hands-free); To activate, momentarily
press TALK button.
MANUAL (Press-to-talk/Release-to-listen); To activate,
press TALK button for 1 sec. or more.
3.5 inch direct-view TFT color LCD.
525 lines
NTSC, 1Vp-p/75Ω
Up to 50cm from camera, with white LED projected,
background beyond 50cm cannot be seen.
24V AC/DC, 500mA (N/O dry closure contact)
24V AC/DC, 1.6A (N/O dry closure contact)
Door to master: 2-cond., mid cap, solid, non-shielded.
Master to sub: 4-cond., mid cap, solid, non-shielded.
Master/sub to door: 50m (0.65mma) 100m (1.0mma)
Master to IER-2: 75m (0.65mma) 150m (1.0mma)
100
125
108.5
25
132
AC-10S
JKW-BA
122.5
25
45
55
68.5
135
98
27
IER-2
129
JK-DVF
27
Power source
Power supply
Consumption
Calling
Communication
83.5
135
JK-DV
173
JK-1SD
185
JK-1MD, JK-1HD
185
JK-1MED
29.5
117
5
45
2
Wide and Zoom & PanTilt Hands-free Color Video Intercom
Wiring
100m / 1.0mma
JK-1MED
or
JK-DV
JK-1MD
JK-1HD
2
VIDEO ENTRY SECURITY
4
2
JK-1SD
or 4
2 IER-2
PS18
A1
A2
DOOR1
SUB
SUB
IN
A1
A2
B1
B2
B1
B2
DOOR RELEASE
L
L
EL-12S
IER-2
CALL EXT
PT
1
E
S
S
DC18V
DC18V
PS18
ON
OFF
Press-to-talk setting
switch (only JK-1MD)
Option
connector
V+
VSW
SW
KS
KE
PS18 :PS-1820S, PS-1820UL, PS-1820
PT
:AC Transformer
Brown
Red
Orange
Yellow
Green
Blue
External sensor input specification
Video signal output
(NTSC, 1Vp-p/75Ω)
N/O dry closure contact
Input method
Option output
(AC/DC24V,16A
N/O dry closure contact)
Detection confirmation time 100 mS or more
Contact resistance
Terminal short current
External sensor input
Setting is required on JK-1MED.
Cable
External sensor input
(start signal only detection method)
Voltage between terminals
During N/O dry closure: Less than 700Ω
During N/C dry closure: more than 3KΩ
Less than 10 mA
Less than 20V DC
(when open between terminals)
Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot
be guaranteed.
Setting up (JK-1MED only)
On JK-1MED, clear screen displays & Indications realize your easy setting up!
(ex: select a language)
Setting name
Time
Language
Door station chime tone
Communication time
Automatic night volume adjustment
Detection
External input
Notification at door
Sound time
Press-to-talk setting
Picture
Recording
※
Screen
are initial views
Setting operations are made by pressing buttons under the screen.
3
Available setting
2008 01/01/ 00:00
English, French, Italian, Dutch, Spanish
♪1 (Tone 1)♪2 (Tone 2)♪3 (Tone 3)♪4 (Tone 4)
1 min. 2 min. 3 min. 5 min.
Enable Disable
N/O N/C Disable
OFF OFF ON
30 sec. Continuous Continous
Enable Disable
・All saved pictures are erased.
・Zoom x 3, Wide x 3
・Wide x 3, Zoom x 3
・Zoom x 6
・Wide x 6
Mounting locations
l Video door station
Do not install a video door station in any of the following locations where lighting or the ambient
environment could impact the display on the video master station due to the characteristics of the door
station's camera.
Under street lights or
door lights
Other locations subject
to strong lighting conditions
VIDEO ENTRY SECURITY
Locations subject
to direct sunlight
l Monitor station
1. Install the master monitor station and sub
monitor station in places where the screens
are not exposed to direct sunlight.
2. The master monitor station and sub monitor
station have switches on both sides. Allow at
least 5 cm of open space on either side.
3. Allow 15 cm or more of vertical open space
from the center of the mounting bracket in
order to mount the master monitor station and
sub monitor station.
JK-1MD / JK-1MED
+ 15 cm
+ 5 cm
+ 5 cm
Image view area
JK-DA, JK-DV, JK-DVF
(WIDE)
approx. 200cm
(WIDE)
(ZOOM & PanTilt)
approx. 225cm
approx. 85cm
approx. 105cm
Zoom (up)
approx. 70cm
approx. 105cm
approx. 95cm
150cm
50cm
Zoom (down)
approx. 85cm
150cm
approx. 75cm
50cm
50cm
(ZOOM)
approx. 90cm
approx. 130cm
approx. 170˚
approx. 70cm
approx. 10cm
Zoom (right)
approx. 130cm
approx. 90cm
approx. 10cm
Zoom (left)
Long distance adaptor for JK series
Wiring
Features
l When JK series color video
door station is more than 100m
to max. 300m away.
200m / 1.2mma
100m / 1.2mma
2 JKW-BA
JK-DV
2
JK-1MED
Used for
JK-1MD, JK-1MED
A1
A2
Unit dimensions
A1 B1
A2 B2
+
–
C
A1
A2
+
–
Cable
1.0mma to 1.2mma. Vinyl jacketed, PE (polyethylene) insulation cable.
JKW-BA
Long distance adaptor
Specifications
Power source
108.5
JKW-BA
122.5
61
Current consumption
Wiring
Distance
18VDC,
PS-1820S, PS-1820UL, PS-1820 of system or
separate
95mA
2 parallel wires to ea. door & master.
JK door~JKW-BA 100m~200m(1.2mma)
JKW-BA~JK master/JK-1HD/JK-1SD 100m(1.2mma)
JKW-BA~PS 100m(1.2mma)
4
Hands-free Color Video Intercom
DOOR
Features
ROOM
1
• One door & two monitors (3.5 inch); room to room
communication is not available
• Total hands-free communication, auto-voice actuation
• Streamlined & Thin design, only 27 mm thickness
• Vandal resistant video door stations are available
• White LED illumination turns on in low-light conditions
1+1 JF-1MD
Door station
Master station
VIDEO ENTRY SECURITY
2
IER-2
2
2
Call extension
m P.97
PT
JF-DV
PS18
Vandal-resistant video
door station, surface mount
JF-1MD
Master station w/color monitor
or
Access Contorol m P.95
AC-10S
Access control
keypad,
surface mount
or
AC-10F
Access control
keypad,
flush mount
JF-DA
JF-DVF
Standard video
door station
Vandal-resistant video
door station
flush mount
JF-DV + AC-10S
Power supply PS-1820S PS-1820UL PS-1820 m P.100
Communication network
Wiring
100m / 1.0mma
JF-DV
JF-1MD
JF-1FD
JF-1MD
2
6
JF-1SD
6
JF-DV
DOOR
A1
A2
A1
A2
M
EL-12S
JF-1SD
PT
CALL EXT
IER-2
S
S
1
E
SUB
SUB
B1
B2
B1
B2
DOOR
RELEASE
DOOR
RELEASE
L
L
L
L
DC18V
DC18V
JF-1FD
PS18
(BR)
(RD)
Room-to-room communication is not available.
BR: Brown RD: Red
(BR)
External
device
(RD)
PRESS TALK
PRESS TALK
ON OFF
ON OFF
PS18
External
device
: PS-1820/S/UL PT : AC Transformer
Cable
Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For
other types of cables, normal operation and max. communication distance
cannot be guaranteed.
5
•
•
•
•
•
•
Instant voice call-in with image
Visual monitoring with audio for 1 minute
Press-to-talk operation available
Talk LED lights in red while speaking
Optional audio sub station (JF-1SD)
Option - Option button, press-to-talk setting
Lineup
Sub station
VIDEO ENTRY SECURITY
6
JBW-BA
Long distance adaptor
m P.21
*Max. 300m away from
Master/sub to Door.
JF-1FD
Sub station
w/color monitor
or
6
JF-1SD
Audio sub
station
KAW-D
30k angled box
m P.22
JBW-D
15k angled box
Boxed sets
JFS-1AD: JF-1MD, JF-DA
JFS-1ADV: JF-1MD, JF-DV
JFS-1ADF: JF-1MD, JF-DVF
Add appropariate power supply
EL-12S
Electric door strike
m P.97
Unit dimensions
Image view area
JF-DA, JF-DV, JF-DVF
JF-1MD, JF-1FD
JF-1SD
★
185cm
(2)
★
210cm
27
135
82
JF-DVF
27
★
50cm
★
40
150cm
5.5
95cm
★
★
50cm
JF-DV
(3)
180cm
★
★
65cm 70cm
65cm
★
140cm
★
115cm
210
179
(1)
120cm
★
JF-DA
approximate
131
209
173
(1) Initial horizontal view (2), (3) When camera is turned up or down (JF-DA only)
Specifications (JF-1MD)
99
98
25
135
29
108.5
120
88
Power source
Power supply
Consumption
Calling
Communication
JBW-BA
83.5
IER-2
45
40
122.5
61
Video monitor
Scanning line
Night viewing
Door release
Option output
Wiring
Wiring distance
18V DC
PS-1820S, PS-1820UL, PS-1820
Max. 450mA (JF-1MD). Max. 300mA (JF-1FD)
Chime. Image & audio, approx. 45 sec.
Approx. 1 min.
AUTOMATIC (Hands-free); To activate, momentarily
press TALK button.
MANUAL (Press-to-talk/Release-to-listen); To activate,
press TALK button for 1 sec. or more.
3.5 inch direct-view TFT color LCD.
525 lines
Up to 30cm from camera, with white LED projected,
background beyond 30cm cannot be seen.
24V AC/DC, 500mA (N/O dry closure contact)
24V AC/DC less than 1.6A (N/O dry closure contact)
Door to master: 2-cond., mid cap, solid, non-shielded.
Master to sub: 6-cond., mid cap, solid, non-shielded.
Master/Sub (farthest room station) to door:
50m (0.65mma) 100m (1.0mma)
Master to IER-2: 75m (0.65mma) 150m (1.0mma)
6
Hands-free Color Video Intercom
Features
DOOR
ROOM
2
3 JF-2MED
• Two doors & three monitors (3-1/2 inch)
• Total hands-free communication, auto-voice actuation
• Built-in picture memory; Record visitor both automatically &
manually
• Voice memo; Internal short voice messages can be recorded
and played back
Door station
Master station
VIDEO ENTRY SECURITY
4
2
2
2
IER-2
Call extension
m P.97
PT
JF-DV
Vandal-resistant video
door station, surface mount
JF-2MED
Master station w/color
monitor and picture memory
2
Access Contorol m P.95
AC-10S
or
Vandal-resistant video
door station
flush mount
AC-10F
JF-D
JF-DA
JF-DVF
Access control
keypad,
surface mount
or
Standard video
door station
Power supply PS-1820S PS-1820UL
Access control
keypad,
flush mount
Audio only door
station
PS-1820 m P.100
Communication network
Wiring
100m / 1.0mma
100m / 1.0mma
JF-DV
JF-DV
JF-2HD
JF-2MED
2
2
JF-2SD
JF-2MED
4
DOOR2
A1
A2
NP
SUB
CALL EXT
S
S
EL-12S
(BR)
(RD)
JF-2SD
JF-2SD
or 2
PS18
B1
B2
M
4
JF-2SD
2 IER-2
A1
A2
NP
A1
A2
JF-2HD
or 2
DOOR1
A1
A2
JF-2HD
2
JF-DVF
M
JF-DV + AC-10S
RELEASE
NP
IER-2
1
E
ON OFF
ON OFF
SUB
IN
SUB
OUT
SUB
IN
SUB
OUT
B1
B2
B1
B2
B1
B2
B1
B2
L
L
PT
PS18
DC18V
DC18V
JF-2HD
JF-DVF
Selective control of door release at communicating Door station.
All-Call the inside stations by voice, then talk individually.
RY-3DL Connection
JF-2MED
RY-3DL
EL-12S
Picture memory
3/16
2006
02 DEC
18 : 45
L1
C1
L1
L2
C2
L2
• Plays 8 shots continuously so that you can see
them as a moving image.
Pause and frame-by-frame play are also available.
8 shots/picture
EL-12S
PT
b1
b2
b3
L
D1
E
D2
OG
YE
GR
BR
RD
b1
b2
E
L
L
DC18V
PRESS THE TALK BUTTON TO END
BR: Brown RD: Red OG: Orange YE: Yellow GR: Green
PS18 : PS-1820/S/UL PT : AC Transformer
7
PS18
• Message for entrance; Outgoing messages can be recorded and sent
out at the door station manually
• Streamlined & Thin design, only 32 mm thickness
• Vandal resistant video door stations are available
• White LED illumination turns on in low-light conditions
• Visual monitoring with audio for 1 minute
• External sensor connectable for notifying and pictograph on monitor
• Instant voice call-in with image
•
•
•
•
•
•
•
•
Different chimes to indicate which door is calling
Press-to-talk operation available
All-Call for internal communication
Transfer of door station call to other inside stations
Selective door release control (with RY-3DL)
Optional audio sub master station (JF-2SD)
Audio door station in lieu of 2nd video door station
Option - Option button, Video signal (NTSC) output, External talk switch,
press-to-talk restriction
Lineup
Sub station
JF-2HD
JF-2HD
4
or
2
or
RY-3DL
JBW-BA
Door release
adaptor
m P.21
Long distance
adaptor
m P.21
*Max. 300m away
from Master to Door
2
JF-2SD
JF-2SD
Audio sub
master station
Audio sub
master station
VIDEO ENTRY SECURITY
Sub master station
w/color monitor
Sub master station
w/color monitor
KAW-D
30k angled box
m P.22
Boxed sets
JFS-2AED: JF-2MED, JF-DA
JFS-2AEDV: JF-2MED, JF-DV
JFS-2AEDF: JF-2MED, JF-DVF
Add appropariate power supply
EL-12S
Electric door strike
m P.97
Unit dimensions
Image view area
5.5
209
(2)
(1)
(3)
65cm 70cm
25
98
JF-DA
25
65cm
50cm
95cm
JF-D
131
JF-DVF
90
32
JF-DA, JF-DV, JF-DVF
130
135
27
JF-DV
173
JF-2SD
160
179
JF-2MED, JF-2HD
(1) Initial horizontal view (2), (3) When camera is turned up or down (JF-DA only)
99
98
40
28.5
Specifications (JF-2MED)
29
25
Cable
33
61
42
74
100
AC-10F
132
125
98
140
122.5
55
68.5
AC-10S
RY-3DL
JBW-BA
108.5
120
88
Power source
Power supply
Consumption
Calling
Communication
45
83.5
135
IER-2
117
5
45
Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For
other types of cables, normal operation and max. communication distance
cannot be guaranteed.
Video monitor
Scanning line
Night viewing
Door release
Wiring
Wiring distance
18V DC
PS-1810DIN
Max. 400mA (JF-2MED). Max. 220mA (JF-2HD)
Chime. Image & audio, approx. 45 sec.
Approx. 1 min.
AUTOMATIC (Hands-free); To activate, momentarily
press TALK button.
MANUAL (Press-to-talk/Release-to-listen); To activate,
press TALK button for 1 sec. or more.
3-1/2 inch direct-view TFT color LCD.
525 lines
Up to 30cm from camera, with white LED projected,
background beyond 30cm cannot be seen.
24V AC/DC, 500mA (N/O dry closure contact)
Door to master: 2-cond., mid cap, solid, non-shielded.
Master to sub: 4-cond., mid cap, solid, non-shielded.
Master to door: 50m (0.65mma) 100m (1.0mma)
Master to farthest sub: 50m (0.65mma) 100m (1.0mma)
Master to IER-2: 75m (0.65mma) 150m (1.0mma)
8
PanTilt Hands-free Color Video & Motion-sensor camera integration
Features
DOOR
ROOM
2
3 JA Series
• Two color PanTilt Camera door stations, three inside monitor
stations (4 inch LCD)
• Motion-sensor camera (max.2)
• Built-in picture memory (JA-2MECD only)
• Surveillance mode SET through sensor-cameras. Activates
monitor and internal alarming (& picture save in JA-2MECD)
Door station
Master station
VIDEO ENTRY SECURITY
Picture
memory
2
2
PT
4
2
2
IER-2
2
Call extension
m P.97
PS24
Standard
or
Non-Picture
memory
JA-DGC
PanTilt color video door
station - semi-flush mount
JA-2MECD
2
PanTilt color monitor
master station,
picture memory
2
PT
or
JA-DAC
PanTilt color video
door station - surface
mount
JA-D
Audio only door stationsurface mount
Power supply PS-2420S
PS-2420UL
JDW-C
Motion-sensor
camera
Motion-sensor
camera
JA-2MCD
PanTilt color monitor
master station
PS-2420 m P.100
Communication network
JA-DGC
PS24
JDW-C
Wiring
100m / 1.0mma
JA-2HCD
100m / 1.0mma
2
JA-DGC
JA-DAC
JDW-C
M
JDW-C
2
or
JA-2MECD
JA-2MCD
JDW-C
2
JA-2HCD
JA-2HCD
4
4
2
JA-2SD
JA-2SD
JA-DAC
A1
A2
JA-DAC
JA-D
1
2
JDW-C
NP
NP
A1
A2
JDW-C
M
or
NP
C1
C2
A1
B1
B1
B1
B1
B1
A2
B2
B2
B2
B2
B2
Cable
Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For
other types of cables, normal operation and max. communication distance
cannot be guaranteed.
NP
C1
C2
JA-2HCD
DC24V
+
+
+
A2
-
-
-
ADAPTER
-1
PS24
BR
PT
RD
OG
PT
YE
A
A
C1
OFF
ADAPTER
-2
CALL
EXT
S
S
C1
C2
EL-12S
EL-12S
DOOR2
A1
C2
JDW-C
JA-2SD
M Door release activation
Hands-free voice-activated communication after TALK button is pressed.
9
DOOR1
or
JA-2MECD,
JA-2MCD
JA-DAC
NP
or 2
or 2
PT
EL-12S
JA-2SD
IER-2
NP
1
E
L1
L1
L2
L2
Wiring for JA-2SD; Two wires only. + / - wires are not necessary.
B1,B2: marked with SUB IN , SUB OUT PS24 :PS-2420/S/UL PT : AC transformer
BR: Brown RD: Red OG: Orange YE: Yellow
ON
•
•
•
•
•
•
•
•
•
•
•
•
Total hands-free communication, auto-voice actuation
Instant voice call-in with image
Press-to-talk available
White LED illuminator turns on in low-light conditions
All Call for internal communication
Transfer of door station call to other inside stations
Optional video (JA-2HCD) or audio (JA-2SD) sub stations
Audio door station in lieu of JA video door station
Talk LED lights in red while speaking
Visual monitoring with audio through all cameras
Two door release contacts for selective control
Options:
-Foot talk switch
-Manual Talk switch restriction
-RY-3DL for large door releases locally available
-Video output to video device (NTSC)
Lineup
Sub station
JA-2HCD
PanTilt color
monitor sub
master station
PanTilt color
monitor sub
master station
4
KAW-D
AC-10S
30k angled box
m P.22
15k angled box
Access control
keypad,
surface mount
m P.95
JBW-BA
AC-10F
Long distance
adaptor
m P.21
Access control
keypad,
flush mount
m P.95
JBW-D
2
or
or
2
JA-2SD
JA-2SD
Audio sub
master station
Audio sub
master station
VIDEO ENTRY SECURITY
JA-2HCD
EL-12S
Electric door strike
m P.97
Unit dimensions
Image view area
JA-DAC, JA-DGC
JA-2MECD
JA-2MCD, JA-2HCD
JA-DGC
220cm
210
172
90cm
210
50cm
★
130cm
★
180cm
★
★
150cm
180cm
★
65cm
42
160
115
42
160
12.5 19 37
50cm
★
JA-2SD
JA-D
98
102
93.5
Calling
Communication
Video monitor
Scanning line
Night viewing
Door release
Wiring
108.5
83.5
120
29
Power source
Power supply
Consumption
182
40
JBW-BA
122.5
88
approximate
28.5
82
IER-2
★
Max. pan-and-tilt view area: 90cm Vert., 180cm Horiz. (approx.)
JDW-C
210
98
44
47.5
★
45cm 90cm
Specifications (JA-2MECD, JA-2MCD, JA-2HCD, JA-2SD)
130
130
JA-DAC
★
61
Wiring distance
24V DC
PS-2420S, PS-2420UL, PS-2420
Max. 750mA(JA-2MECD).Max. 680mA(JA-2MCD).
Max. 290mA(JA-2HCD). Max. 120mA(JA-2SD)
Chime. Image & audio, approx. 30 sec.
AUTOMATIC (Hands-free); To activate, momentarily
press TALK button.
MANUAL (Press-to-talk/Release-to-listen); To activate,
press TALK button for 2 sec. or until talk LED turns on.
4 inch direct-view TFT color LCD.
525 lines
White LED projected up to 30cm from camera.
24V AC/DC, 500mA (dry closure contact L, L)
Parallel, station to station(non-twisted, non- shielded).
Vinyl-jacket, PE insulation.
Master station ~ Door 50m(0.65mma) 100m(1.0mma)
Master station ~ Motion sensor camera 50m(0.65mma) 100m(1.0mma)
Master station ~ farthest sub 50m(0.65mma) 100m(1.0mma)
Master station ~ IER-2 50m(0.65mma) 100m(1.0mma)
10
Video Sentry Color Tilt
DOOR
ROOM
1
1 KCS-1ARD
Door station
Features
• Clear and bright image with color TFT LCD monitor and DSP
video door station
• TILT camera control
• INSTANT ON audio & image of entry when called
Master station
VIDEO ENTRY SECURITY
2
2
2
PT
KC-DAR
PS24
Video door station
KC-1MRD
Master station
Power supply PS-2420S
PS-2420UL
Communication network
PS-2420 m P.100
Wiring
100m / 1.0mma
100m / 1.0mma
KC-1MRD
KC-DAR
IER-2
2
KC-DAR
KC-1MRD
NP
4-tone chime
M
Tilt camera control
2
2
A1
A2
M
N
H
A1
A2
S
S
+
–
1
E
N
EL-12S
H
l Run audio/video wires in a separate jacketed cable from door release wires.
N : PS-2420/S/UL H : AC transformer
Cable
Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For
other types of cables, normal operation and max. communication distance
cannot be guaranteed.
11
• Hands-free monitoring audio & image of door
• Video door station's white LED illumination automatically turns on in
the darkness
• Locator LED backlight on CALL button
Lineup
KAW-D
AC-10S
Picture memory
unit
m P.21
30k angled box
m P.22
Access control
keypad,
surface mount
m P.95
EL-12S
KA-DGR PANEL
Electric door
strike
m P.97
Stainless steel
housing
for KC-DAR
AC-10F
IER-2
Call extension
m P.97
Boxed sets
Long distance
adaptor
m P.21
Unit dimensions
Image view area
KC-DAR
KC-DAR
KC-1MRD
124cm
83.5
195
83.5
140
130cm
111cm
185
88
JBW-BA
61
83.5
120
122.5
Video monitor
Scanning lines
Image view area
29
KA-DGR PANEL
83.5
55.4
Night viewing
Door release
Wiring
Distance
151
142
KAW-D
105
50cm
★
60cm ★
109
42
approximate
Specifications (KC-1MRD)
Power source
Power supply
Communication
108.5
IER-2
4.5
★
50cm
44
107
★
235cm
★
88
Access control
keypad,
flush mount
m P.95
JBW-BA
KCS-1ARD: KC-DAR & KC-1MRD
add appropriate power supply
105
VIDEO ENTRY SECURITY
KC-32EU
24V DC, 450mA. 50mA standby
PS-2420S, PS-2420UL, PS-2420
Door calls in w/4-tone chime & image, 30 sec. timed.
Lift handset to reply, 2-1/2 min. timed. In standby,
press MONITOR to view and hear door.
4 inch TFT color LCD
525 lines
Approx. 60cm horiz., 111~235cm vert.
at 130cm high and 50cm from camera.
White light projected up to 30cm from camera. The
background scene beyond 30cm cannot be seen.
12V AC, 400mA.
2 parallel wires to door, non-polarized.
KC-1MRD ~ door 50m(0.65mma) 100m(1.0mma)
KC-1MRD ~ IER-2 50m(0.65mma) 100m(1.0mma)
30˚
12
Video Sentry Color Tilt
DOOR
ROOM
1
3 KC-1GRD
Door station
Features
•
•
•
•
VIDEO SENTRY COLOR TILT 1 door - 3 monitors
INSTANT ON door audio & video
All call type room calling
100m distance between monitors, looped
Master station
VIDEO ENTRY SECURITY
2
2
IER-2
2
2
Call extension
m P.97
2
PT
KC-DAR
Video door station
KC-1GRD
Master station
2
PS24
PS24
Power supply PS-2420S PS-2420UL
PS-2420 m P.100
Communication network
Wiring
100m / 1.0mma
100m / 1.0mma
IER-2
KC-1HRD
4-tone
chime
2
2
KC-1SD
KC-DAR
KC-1HRD
KC-1GRD
KC-DAR
NP
KC-1GRD
KC-1GRD
2
2
2
2
M
Tilt camera
2
2
N
N
H
(1)
M
KC-1SD
A
KC-1SD
KC-1HRD
A1
A2
A1 B1
A2 B2
+
-
N
KC-1HRD
B
A1 B1
A2 B2
A
+
+
-
N
EL-12S
B
A1 B1
A2 B2
or
A
H
B
A1
S
S
1
E
A2
l Run audio/video wires in a separate jacketed cable from door release wires.
N : PS-2420/S/UL
H : AC transformer
Cable
(1) All call type voice calling (from any).
Communication on handsets individually.
13
Vinyl jacketed, PE (polyethylene) insulation cable is recommended. For
other types of cables, normal operation and max. communication distance
cannot be guaranteed.
• TILT camera control
• Hands-free monitoring audio & image of door
• Video door station's white LED illumination automatically turns on in
the darkness
Lineup
Sub station
KA-DGR PANEL
Stainless steel
housing
for KC-DAR
KC-1HRD
Access control keypad,
surface mount
m P.95
KC-1HRD
Sub master station
Sub master station
or
AC-10F
KAW-D
Access control keypad,
flush mount
m P.95
30k angled box
m P.22
or
2
2
2
KC-1SD*
JBW-BA
KC-1SD*
Audio sub
station
*Not available in Europe
Audio sub
station
*Not available
in Europe
Long distance
adaptor
mP.21
EL-12S
KC-32EU
MCW-S
Electric door strike
m P.97
Picture memory
unit
m P.21
★
KC-DAR
KC-1SD
124cm
★
50cm
235cm
83.5
210
83.5
195
130cm
★
111cm
50cm
100
KC-DAR
88
44
83.5
29
83.5
4.5
55.4
61
Power supply
Video monitor
Scanning lines
Communication
151
142
107
105
122.5
KA-DGR PANEL
KAW-D
Power source
Consumption
JBW-BA
120
140
83.5
IER-2
109
60cm★
★
approximate
Specifications (KC-1GRD)
74
108.5
88
105
Monitor desk stand
mP.22
Image view area
Unit dimensions
KC-1GRD, KC-1HRD
185
AC-10S
VIDEO ENTRY SECURITY
2
42
Image view area
30˚
Night viewing
Door release
Wiring
Distance
24V DC
KC-1GRD: 450mA. 70mA standby.
KC-1HRD: 200mA. 50mA standby.
KC-1SD: 70mA. 50mA standby.
PS-2420S, PS-2420UL, PS-2420
4 inch TFT color LCD
525 lines
Door calls in w/4-tone chime, 30 sec. Hear and see
door instantly. Pick up at any station to reply, 2-1/2
min. timed. Recycle with MONITOR. Monitor hands-free
audio & image of door w/MONITOR. Press ALL CALL to
call the other w/pretone & voice. Lift either handset to
reply.
Approx. 60cm Horiz., 111~235cm Vert. at 50cm in
front of camera at 130cm high.
Up to 30cm from camera, with white LED projected.
Background scene beyond 30cm cannot be seen.
Contact rating: 12V AC, 400mA.
2 parallel wires to door, non-polarized.
2 wires in loop between monitors, plus 2 wires
separately run from power supply.
KC-1GRD ~ door 50m(0.65mma) 100m(1.0mma)
KC-1GRD ~ farthest sub 50m(0.65mma) 100m(1.0mma)
KC-1GRD ~ IER-2 50m(0.65mma) 100m(1.0mma)
14
Video Sentry Color Tilt
Features
DOOR
ROOM
3
5 KB-3MRD
•
•
•
•
•
Door station
3 doors & 5 monitors w/TILT camera control.
INSTANT ON audio & image of door.
Selective calling or All Call.
Audio sub station in lieu of monitor.
Optional audio door at 3rd entry.
Master station
VIDEO ENTRY SECURITY
KB-DAR
Video door
station
2
2
2
PT
2
IER-2
2
KB-DAR
Video door
station
Call extension
m P.97
2
KB-3MRD
Master station
2
or
PS24
KB-DAR
Video door
station
IF-DA
Audio door station
Power supply PS-2420S
PS-2420UL
PS-2420 m P.100
Communication network
Wiring
200m / 1.0mma
KB-DAR
KB-DAR
KB-3HRD
4-tone
chime
Tilt camera control
M
KB-DAR
IER-2
KB-3HRD
2
NP
2
KB-3MRD
(1)
2-tone chime
Tilt camera control
KB-3HRD
KB-3MRD
2 KB-3HRD4
2
2
2
2
2
KB-3SD
KB-3HRD
2
2
M H
KB-DAR
2
A1
A2
KB-3SD
2A1 +
2A2 A1
A2
IF-DA
Cable
B
1A1 B1
1A2 B2
N
N
2
A
B
1A1 B1
1A2 B2
A
B
1A1 B1
1A2 B2
A
+
+
-
+
-
N
1
E
or
A
H
B
1A1 B1
1A2 B2
+
-
S
S
EL-12S
Cable specified for wiring to both door and inside stations
l 0.65mma to 1.2mma dia.
l PE(polyethylene) insulation & vinyl jacketed cable
l Attenuation: less than -6.5dB at 10MHz./100m length.
l Solid copper conductor.
l Line impedance: c75 ohm (less than 100 ohm at the highest).
3A1
3A2
D1
E1
(1) Selective Call or All Call type voice calling (from any).
Communication on handsets individually.
2
KB-3SD
1A1 B1
1A2 B2
A1
A2
2
NN
N
A
8-tone chime
Tilt camera control
15
100m / 1.0mma
b1
b2
b3
E
B
A1 B1
A2 B2
(1)
l D1, E1 : for IF-DA door station instead of third KB-DAR.
l Run audio/video wires in a separate jacketed cable from door release wires.
N : PS-2420/S/UL
H : AC transformer (1) External light control
•
•
•
•
Push chime or receiver volume control.
Optional selective door release with RY-3DL.
Hands-free monitoring audio & image of door.
Video door station's white LED illumination automatically turns on in
the darkness.
Lineup
Sub station
KB-3HRD
KB-3HRD
KB-3HRD
Sub master
station
Sub master
station
Sub master
station
Sub master
station
2
2
KC-32EU
Picture memory
unit
m P.21
2
AC-10S
Access control keypad,
surface mount
m P.95
or
KA-DGR PANEL
Stainless steel
housing
for KB-DAR
2
AC-10F
Access control keypad,
flush mount
m P.95
VIDEO ENTRY SECURITY
KB-3HRD
2
KB-3SD
2
Audio sub
station
max. 2pcs
2
PS24
KAW-D
30k angled box
m P.22
EL-12S
RY-3DL
MAW-B
Door release
adaptor
m P.21
Auxiliary light
control relay
m P.98
Electric door strike
m P.97
2
PS24
Unit dimensions
Image view area
KB-3MRD, KB-3HRD
KB-DAR
★
124cm
KB-DAR
★
50cm
235cm
★
111cm
83.5
195
140
83.5
130cm
50cm
105
approximate
44
Specifications (KB-3MRD)
KB-3SD
185
84
Power source
Consumption
83.5
120
210
83.5
IER-2
Power supply
Video monitor
Scanning lines
Communication
29
88
100
74
KAW-D
151
142
KA-DGR PANEL
107
109
60cm★
★
42
105
83.5
4.5
55.4
Image view area
30˚
Night viewing
Door release
Wiring
Distance
24V DC
KB-3MRD: max.710mA, 230mA standby
KB-3HRD: max. 260mA, 80mA standby
KB-3SD: max 85mA, 50mA standby
PS-2420S, PS-2420UL, PS-2420
4 inch TFT color LCD
525 lines
Door calls in w/4-tone chime, 30 sec. Hear and see
door instantly. Pick up at any station to reply, 2-1/2
min. timed. Recycle with MONITOR. Monitor audio&
image of door hands-free w/MONITOR. Press a station
selector and call by voice. The called station replies
hands-free. Lifting handset, press ALL CALL button to
call the other stations w/pretone and voice.
Approx. 60cm Horiz., 111~235cm Vert. at 130cm high
& at 50cm in front of camera.
Up to 30cm from camera, with white LED projected.
Background scene beyond 30cm cannot be seen.
Contact rating: 12V AC, 400mA
2 parallel wires to door, non-polarized.
2 wires in loop between monitors, plus 2 wires
separately run from power supply.
KB-3MRD ~ door 100m(0.65mma) 200m(1.0mma)
KB-3MRD ~ farthest sub 50m(0.65mma) 100m(1.0mma)
KB-3MRD ~ IER-2 50m(0.65mma) 100m(1.0mma)
16
Hands-free Color Video Intercom
MASTER
8
Features
DOOR
• Up to 120 video entrance stations and 8 master stations
• All wired on CAT5e, homerun cabling
• Total hands-free, auto-voice actuation, communication or
Press-to-talk operataion
120 AX
Door station
Central exchange unit
Cat5e
VIDEO ENTRY SECURITY
2
Cat5e
PT
2
PS24
AX-084C
PS24
Central exchange unit,
4 masters and 8 doors
AX-248C (Photo)
AX-DV
Central exchange unit,
8 masters and 24 doors
Color video
door station
surface mount
AX-DV-P
AX-DM
Color video
door station
w/space for embed
proximity reader
Audio door station
Mullion type
AX-320C
Add-on exchange unit,
32 doors
PT
AX-DVF
Color video
door station
flush mount
AX-DVF-P
IE-JA
Color video door station
w/space for embed
proximity reader
Audio door station
Communication network
Power supply
PS-2420S PS-2420UL
m P.100
PS-2420
Wiring
300m
300m
Master #1
AX-8MV
Door #1
AX-DV
Cat5e
Cat5e
RJ-45
AX-DV
RJ-45
Cat5e
Cat5e
RJ-45
AX-8MV
Master #8
AX-8MV
AX-248C
Door #24
AX-DVF
2
AX-8MV
2
AX-DVF
Door #1
AX-DV
RJ-45
N
N
Master #1
AX-8MV
RJ-45
Cat5e
M
Video
signal
AX-DM
AX-248C
RJ-45
H
+ -+-
Cat5e
Door #24
AX-DVF
N
N
Cat5e
Monitor
RJ-45
M
Cat5e
H
Calling & communication (w/video from door)
Door release
17
N : PS-2420S, PS-2420UL, PS-2420 H : AC transformer
RJ-45
Master #8
AX-8MV
•
•
•
•
•
•
•
•
•
•
•
•
•
Two talk channels and two video channels
Communication privacy
Masters available with 3.5 inch color TFT LCD
Selective door release
Master-to-master selective calling and All Call
Standard or Priority call levels from door stations
Scan monitoring:Hands-free audio/visual monitoring
Video output from CEU and AX-8MV
Integrate with CCTV, Access control etc.
PC interface for programming and event logging
Rack or wall mountable CEU
Compatible with IE Series door stations
Optional features: headset, footswitch, and PC remote control
Lineup
Master station
EL-12S
Electric door strike
m P.97
AX-8MV
AX-16SW
8-call color monitor master station
16-call add-on selector
Cat5e
VIDEO ENTRY SECURITY
Cat5e
AC-10S
Access control
keypad,
surface mount
m P.95
AX-8M
AX-8MV, AX-16SW
8-call audio master station
AC-10F
Access control
keypad,
flush mount
m P.95
Unit dimensions
Image view area
AX-8MV
AX-8M
• AX-DV, AX-DVF, AX-DV-P, AX-DVF-P
175
175
185cm
65cm
120cm
150cm
194
63
63
194
AX-084C, AX-248C
AX-320C
86
Power source
Power supply
Current consumption
88
85
Calling
63
AX-DV
AX-DV-P
AX-DVF
246
245
195
Communication
100
Video monitor
Scaning lines
Night viewing
25
146
100
AX-DVF-P
2 45
25
Door release contact
Outside video output
IF-DA
130
AX-DM
295
160
1-gang
98
28
IE-JA
146
22.5
115
43
2-gang
2 45
116
50cm
95cm
★
approximate
Specifications (AX)
420
426
88
85
175
420
426
★
50cm
★
AX-16SW
★
★
Wiring
Wiring distance
24V DC, 2A (Two Power supplies per video system)
PS-2420S, PS-2420UL, PS-2420
AX-084C: Video (Max.) 650mA, Audio (Max.) 700mA
AX-248C: Video (Max.) 1150mA, Audio (Max.) 1250mA
AX-320C: Video (Max.) 280mA, Audio (Max.) 180mA
Normal call: an intermittent tremolo
Priority call: a rapid intermittent tremolo
Approx. 10-600 sec. or infinite
AUTOMATIC (Hands-free); To activate, momentarily
press TALK button.
MANUAL (Press-to-talk/Release-to-listen); To activate,
press TALK button for 1 sec. or more.
Approx. 30-600 sec.
3.5 inch direct view TFT color LCD
525 lines
Up to 30cm from camera, with white LED projected,
background beyond 30cm cannot be seen.
24V AC/DC, 0.5A
AX-084C, 248C: NTSC standard 1Vpp (0.7-1.4Vpp)
BNC x 2
Switching signal: Open collector output
24V DC, 30mA
RJ-45 x 2
AX-8MV: NTSC standard 1Vpp (0.7-1.4Vpp)
Homerun CAT5e wire to CEU
CEU to door: 300m (CAT5e)
CEU to master: 300m (CAT5e)
10
18
Wide Angle Video Sentry
DOOR
ROOM
1
3 MK-1GD
Door station
Master station
Features
•
•
•
•
•
•
VIDEO ENTRY SECURITY
4
MK-2DA
2
Sub master
station
2
MK-1GD
Master station
or
Two-call video
door station
m P.22
MK-1HD
PS18
PT
Video door
station
Lineup
Sub station
2
MK-DV
Single-door, three-monitor system with door release
Instant voice call-in with image
Internal handset communication. All call type voice calling
Transfer of door call-in. (Image of caller remains on)
Fixed camera, wide angle viewing
Infrared LED's projected on callers at 50cm in the darkness
MK-2DG
Two-call video
door station
m P.22
or
4
4
IER-2
Call extension
m P.97
or
MK-2SD
Video door station
Video door station
Electric door
strike
m P.97
KAW-D
30k angled box
m P.22
MK-1HD or
MK-DH
MK-DVF
EL-12S
Audio sub
master station
Sub master
station
4
Boxed sets
MKS-1GD: MK-1GD & MK-DH
MKS-1GDV: MK-1GD & MK-DV
MKS-1GDVF: MK-1GD & MK-DVF
MK-2SD
Audio sub
master station
Add appropriate power supply
KC-32EU
MKW-P
Picture memory
unit
m P.21
MK-DV Gang box
mounting plate
Power supply PS-1820S PS-1820UL PS-1820 m P.100
Communication network
Wiring
200m / 1.0mma
75m / 1.0mma
MK-1HD
MK-DV
MK-2SD
2
2
4-tone
chime
M
M
MK-2SD
A1
A2
H
NP
MK-1HD
Instant voice calling w/image. All call with pre-tone/voice.
Internal communication on handsets
EL-12S
Unit dimensions
MK-1GD, MK-1HD
4
4
MK-1GD
MK-DV
MK-1HD
MK-1HD
IER-2
MK-1GD
H
2
U
DOOR SUB
B1
A1
A2
B2
NP
CALL EXT IER-2
1
S
E
S
RLSE. DC18V
+
L
L
P
U
SUB
IN OUT
B1
B1
B2 B2
NP
DC18V
IN OUT
+
+
DC18V
IN OUT
+
+
SW1
OFF
SUB
IN OUT
B1 B1
B2 B2
P
SW1
ON
l MK-2SD may be wired in the same manner as MK-1HD.
U : PS-1820S, PS-1820UL, PS-1820 H : AC transformer SW1-ON Terminated
MK-2SD
200
210
Specifications
60/
83.5
Power sourse
Consumption
60/
83.5
Power supply
Calling
Communicarion
69
215
MK-DV
89
61
130
MK-DH
209
173
MK-DVF
83.5
98
98
19
27
135
45
5.5
35
Video monitor
Scanning lines
Minimum illumination
Door release
Wiring
Distance
18V DC
MK-1GD : (Max.) 650mA, MK-1HD : (Max.) 450mA
MK-2SD : (Max.) 150mA
PS-1820S, PS-1820UL, PS-1820
Chime, audio & image, approx. 45 sec.
Simultaneous with handsets, approx. 2-1/2 min.
Extend w/MONITOR. All call type voice calling, common talk.
4 inch direct view flat CRT
525 lines
1 Lux or less at 30cm distance
12V AC, 0.4A dry-closure contact(L, L)
2 conductors to door
4 conductors betweens room stations
Door to MK-1GD 200m(1.0mma)
MK-1GD to farthest sub 75m(1.0mma)
MK-1GD to PS18 10m(1.0mma)
PanTilt Video Sentry
DOOR
ROOM
2
3 MK-2MCD
Door station
Master station
Features
•
•
•
•
•
•
Two-PanTilt door, three-monitor system with door release
Instant voice call-in with image
Internal handset communication. All call type voice calling
Transfer of door call-in. Image of a caller stays on
Optional audio door station at second entrance
Infrared LED's projected on callers at 50cm in the darkness
Lineup
Sub station
2
4
KC-32EU
PT
MK-DBC
MK-2HCD
PS18
Video door
station
Sub master
station
2
MK-2MCD
Master station
2
4
MK-D*
Picture memory Audio door
unit
station
m P.21
*Not available
in Europe
or
4
VIDEO ENTRY SECURITY
2
IER-2
Call extension
m P.97
MK-2SD
Audio sub
station
EL-12S
RY-3DL
Electric door
strike
m P.97
Door release
adaptor
m P.21
MKW-R
KAW-D
Surface mount
box
for MK-DBC
30kangled box
m P.22
MK-2HCD or
or
Sub master
station
or
MK-DGC
4
Video door station
MK-DAC
MK-DH
Video door station
Video door station
Fixed camera
MK-2SD
Audio sub
station
Power supply PS-1820S PS-1820UL PS-1820 m P.100
Communication network
Wiring
100m / 1.0mma
MK-DBC
MK-2SD
4-tone
chime
MK-2MCD
MK-DGC
PanTilt control
IER-2
MK-2MCD
2
2
2
MK-D
MK-DBC
2-tone
chime
M
MK-DGC
MK-D
H
MK-DGC
M
A1
A2
1
2
MK-2HCD
NP
MK-D NP
Instant voice calling w/image. Pan/tilt camera from any inside monitor station.
All call initiated w/pre-tone/voice. Internal communication on handsets.
EL-12S
MK-2SD
92
170
200
210
Power sourse
Consumption
Power supply
Calling
Communicarion
63
130
89
98
83.5
92
130
MK-DAC
83.5
MK-D
44
47.5
98
35
130
69
115 12.5 19 37
U
SUB
SUB
IN OUT
IN OUT
B1 B1
B2 B2
NP
DC18V
RLSE. DC18V
+
L
L
DC18V
IN OUT
+
U
P
IN OUT
+
SW1
B1 B1
B2 B2
+
P
+
SW1
ON
Specifications
12.5 19 37
MK-DH
MK-DBC
2
l MK-2SD may be wired in the same manner as MK-2HCD.
U : PS-1820S, PS-1820UL, PS-1820 H : AC transformer SW1-ON Terminated
MK-DGC
114
215
H
MK-2HCD
4
OFF
Unit dimensions
MK-2MCD, MK-2HCD
MK-2HCD
4
DOOR1 SUB
1A1
B1
1A2
B2
NP
CALL
DOOR2 EXT IER-2
1
2A1
S
E
S
2A2
NP
A1
A2
MK-2SD
172
75m / 1.0mma
MK-2HCD
MK-DBC
98
83.5
28
Video monitor
Scanning lines
Minimum illumination
Door release
Wiring
Distance
18V DC
MK-2MCD: (Max.) 750mA, MK-2HCD: (Max.) 450mA
MK-2SD: (Max.) 70mA
PS-1820S, PS-1820UL, PS-1820
Chime, audio & image, approx. 45 sec.
Simultaneous with handsets, approx. 2-1/2 min.
Extend w/MONITOR. All call type voice calling, common talk.
4 inch direct view flat CRT
525 lines
1 Lux or less at 30cm distance
12V AC, 0.4A dry-closure contact(L, L)
2 conductors to door
4 conductors between inside stations
Door to MK-2MCD 100m(1.0mma)
MK-2MCD to farthest sub 75m(1.0mma)
MK-2MCD to PS18 10m(1.0mma)
20
Video Accessories
Picture memory unit
Features
Wiring
VIDEO ENTRY SECURITY
l Easy add-on to present or new
system, color or black & white
l 4 pictures in 1 frame (16 frames),
16, 32 or 60 individual picture
save mode
l Max. 8 pictures stored in memory
IER-2
KC-DAR
KC-32EU KC-1GRD
2
2
2
M
N
KC-1MRD, KC-1GRD, KB-3MRD,
MK-1GD, MK-2MCD
NP
A1
A2
A1
A2
B1
B2
Unit dimensions
KC-32EU
Picture memory unit
KC-32EU
2
2
2
A
NP
1A1 B1
1A2 B2
N
EL-12S
2
N
H
Used for
KC-1HRD
KC-1HRD
2
B
1A1 B1
1A2 B2
A
NP
N
195
IER-2
80
1
E
S
S
83.5
H : AC transformer
N : PS-2420S, PS-2420UL, PS-2420
54.5
Single-gang mounting
Specifications (KC-32EU)
KC-1GRD
Power source
Power supply
Channel
Wiring
KC-32EU
Master station Picture memory unit
Wiring distance
18V DC, 230mA, 24V DC, 160mA
PS-1820S, PS-1820UL, PS-1820, PS-2420S, PS-2420UL, PS-2420
One video door per unit
2 parallel wires to door (NP).
2 wires to Master (Polarized).
KC-32EU to door 50m(0.65mma) 100m(1.0mma)
KC-32EU to master 25m(0.65mma) 5m(1.0mma)
KC-32EU to Power supply 10m(1.0mma) (20m w/1.2mma)
Long distance adaptor for color
Features
Wiring
l When JA, JB, KC color video
door station is more than 100m
to max. 350m away, or JF color
video door station is more than
100m to max. 300m away.
l One required for each door station.
250m / 1.2mma
JF-DV
JBW-BA
JBW-BA
1.0mma to 1.2mma. Solid copper conductor PE insulation (not PVC).
Specifications
18VDC, 24VDC
PS-1820S, PS-1820UL, PS-1820, PS-2420S,
PS-2420UL, PS-2420 of system or separate
120mA
2 parallel wires to ea. door & master.
JA, KC door~JBW-BA 100m~300m(1.2mma)
JBW-BA~JA, KC master 50m(1.2mma)
JF door~JBW-BA 100m~250m(1.2mma)
JBW-BA~JF master/JF-1FD/JF-1SD 50m(1.2mma)
JBW-BA~PS 50m(1.2mma)
Current consumption
Wiring
Distance
108.5
Long distance adaptor
61
122.5
C
A1
A2
+
–
Cable
Power source
Unit dimensions
JF-2MED
A1 B1
A2 B2
+
–
A1
A2
Used for
KC-1MRD, KC-1GRD
KC-32EUKC-1ARD/KC-1GRD
JA-2MECD, JA-2MCD
JF-1MD, JF-2MED
50m / 1.2mma
JBW-BA
Selective door release adaptor
Wiring
Features
l Selective door release with one button
l Door release contacts release
the door where communication
is established.
l Normally open contacts for electric
strike. Normally closed contacts to
work with magnetic locks.
EL-12S
RY-3DL
L1
C1
L1
EL-12S
L2
C2
L2
EL-12S
L3
C3
L3
Used for
KB-3MRD, MK-2MCD, IE-2AD(U)
JF-2MED
RY-3DL
H
Specifications
Door release adaptor
Power source
Power supply
Relay contacts
140
74
42
Wiring distance
21
N
GR: Green BL: Blue PL: Purple OG: Orange YL: Yellow
H : AC transformer N : PS-2420/S/UL
Unit dimensions
RY-3DL
KB-3MRD
CN12
GR
BL
PL
CN11
OG
YL
b1
b2
b3
L
D1
E
D2
B
1A1 B1
1A2 B2
12~24V DC, 30mA 12~16V AC, 60mA
PS-2420/S/UL; PS-1820/S/UL; PS-1225/S/UL; AC trans.
Normally open output. 1A at 50V AC. 1A at 30V
DC (for other types, use matching relay)
Master to RY-3DL 50m(0.65mma) 100m(1.0mma)
RY-3DL to EL-10S 50m(0.65mma) 100m(1.0mma)
30kangle box
Features
Image view area
l 30k Angle Box for mounting video door station
to position door camera to view visitors better.
l Designed for 1-gang surface mounting.
KAW-D
30 Used for
KC-DAR
KC-DAR, KB-DAR, MK-DH
m
50c
★
m
60c
VIDEO ENTRY SECURITY
Unit dimensions
142
KAW-D
KAW-D
*Figure is approximate.
83.5
30k angled box
107
55.4
4.5
30˚
105
Desk-top stand
Used for
MK-1GD, MK-1HD
MK-2MCD, MK-2HCD
KC, KB monitors
MCW-S
Monitor desk
stand
Dual-call door station for B&W
Features
Cabling
Call two monitors (MK-1GD)
selectively.
Each monitor is powered by a
separate power supply.
l Wide-angle view
l Camera angle adjuster (16k
upward)
l Backlit call buttons
l Acrylic nameplates for
engraving
l While one monitor is in use,
the other monitor is not
operational.
MK-2DA
MK-2DG
Two-call video door
station
Two-call video door
station
MK-2DG
MK-2DA
MK-2DG PANEL
206
189
Panel only
35
119
120
U
4
MK-2DA
2
2
4
M
U
PT
U : PS-1820S, PS-1820UL H : AC transformer
Specifications
Power source
Camera
Scanning lines
Minimum illumination
Image view area
Wiring
Wiring distance
Unit dimensions
MK-2SD
MK-1GD
34
Supplied by monitor in use
CCD camera w/infrared LED’s
525 lines
1 Lux at 50cm from camera
70cm Vert. x 110cm Horiz. at 50cm
2 parallel wires, polarized
Door to monitor 50m(0.65mma)
100m(1.0mma)
Long distance adaptor for B&W
Features
Cabling
l When B&W video door station
is more than 100m to max.
300m away.
l Separate power supply allows
mounting MYW-BA up to
50m away from master
station or adaptor.
U : PS-1820S, PS-1820UL, PS-1820
Used for
Cable
MK-1GD, MK-2MCD
2
4
MK-1GD
U
Specifications
Power source
Current consumption
Wiring
Distance
MYW-BA
190
Long distance adaptor
80
MYW-BA
Impedance: 90d. Permitted closed loop DC resistance:
9.9d or less. PE insulation (not PVC).
Unit dimensions
MYW-BA
MK-DV
42
PS-1820/S/UL of system or separate
250mA 1mA standby
2 parallel wires to ea. door & master.
MYW-BA~door 200m(1.0mma)
300m(1.2mma)
MYW-BA~master 50m(1.0 or 1.2mma)
MYW-BA~PS 7m(1.0mma)
10m(1.2mma)
22
Two-Wire Electric Lock Door Phone
DOOR
ROOM
1
1 DA-1AS
Lineup
Boxed set
DA-1AS
DA-1AG
Kit box (silver color)
Kit box (gray color)
EL-12S
AC-10S
Electric door
strike
m P.97
Access control
keypad,
surface mount
m P.95
DAR-1
Call extension
AUDIO ENTRY SECURITY
Door station
silver panel
Master station
Access control
keypad,
flush mount
m P.95
DA-1MD
Door station
gray panel
DA-1MD
AC-10F
Master station
DAW-P
*Add an appropriate power supply.
Door station
mounting plate
(83.5mm)
*Add an appropriate power supply.
Power supply
PT-1211D PT-1211C m P.99
Features
Wiring
l Two-wire system including door release
l Door release wired to door station, requiring no power
transformer
l User-optional function button
l Call tone MUTE with indicator
l Call extension sounder
310m / 1.0mma
155m / 1.0mma
DA-1MD
DA-1DS
DA-1DG
M
2
DAR-1
2
NP
2
2
P
Communication network
PT-1211D/C
(1)
EL-12S
DA-1DS,
DA-1DG
DA-1MD
DAR-1
(2)
L
L
~
~
D
E
D
E
PT-1211D/
PT-1211C
S
SE
SW
SW
M
Unit dimensions
DA-1MD
89
22
200
175
100
61
Specifications (DA-1AS, G)
Power source
Power supply
Communication
Wiring
Distance
23
(3)
l Place PT-1211D/C inside electrical enclosure and connect to breaker, less than
16A.
l Do not use PT-1211D/C for any other equipment.
l Terminals SW, SW; Dry-closure contact 18V AC, 40mA to connect user-optional
function (Gate, Light, Garage, Proximity Access Control, etc.)
(1) External device Relay/Controller
(2) Door release (16V AC, 20d or more)
(3) User-optional function (18V AC, 40mA)
Hold down gCALLh button to ring inside station.
DA-1DS,
DA-1DG
S
SE
15V AC
PT-1211D, PT-1211C
Press and hold down Button to call.
2 wires, throughout system: PS - Master - Door
- Door release
PT-1211D/C ~ Door rlse. 110m(0.6mma)
200m(0.8mma) 310m(1.0mma)
PT-1211D/C ~ DA-1MD 55m(0.6mma)
100m(0.8mma) 155m(1.0mma)
Chime Tone Intercom
DOOR
ROOM
1
1 C-123L/A
Door station
Master station
Lineup
AC-10S
Access control keypad,
surface mount
m P.95
C-D
Door station
C-ML/A
Master station
C-123L/A
Chime-Com boxed set
Power supply
PS-0602D PS-0602C or Batteries
EL-12S
Electric door
strike
m P.97
m P.99
Features
Wiring
l Open voice door answering with door release control
l Adjustable communication volume
l Automatically turns off
l Battery or DC power supply
AUDIO ENTRY SECURITY
AC-10F
Access control keypad,
flush mount
m P.95
Boxed set
115m / 0.8mma
C-ML/A
C-D
2
NP
M
Communication network
1
E
+
–
1
E
EL-12S
W
L
L
H
C-ML/A
C-D
H : AC transformer W : PS-0602D, PS-0602C
M
Specifications (C-123L/A)
Power source
Power supply
Communication
Unit dimensions
C-D
C-ML/A
Wiring
88
83.5
190
120
83.5
Distance
6V DC, 85mA
PS-0602D, PS-0602C or Batteries gCh(SUM-2) x 4 pcs.
Door calls in w/2-tone chime, not adjustable.
Press TALK button to reply, release to listen. Power
automatically shuts off circuit.
2 parallel wires to door, non-polarized
(+ 2 for EL-12S).
Master to door 75m(0.65mma) 115m(0.8mma)
29
130
44
24
Chime Tone Intercom
DOOR
ROOM
1
1 TCS-MH
Door station
Master station
TC-DC
Door station
Boxed set
AUDIO ENTRY SECURITY
TCS-MH
Chime-Phone set
TC-MH
Master station
Features
Wiring
l Chime-phone intercom set, battery-operated
l Adjustable chime volume
l Battery status indicator
230m / 0.8mma
TC-MH
TC-DC
2
P.
Communication network
1
2
1
2
R
TC-MH
TC-DC
R : Batteries P. Polarized
Specifications (TCS-MH)
Power source
Power supply
Communication
Unit dimensions
28
80
25
83.5
210
130
98
Wiring
Distance
TC-MH
83.5
TC-DC
58
6V DC, 70mA
Batteries gAAh(SUM-3) x 4 pcs
Door calls in w/2-tone chime, adjustable. Pick up to
reply.
2 parallel wires, polarized.
TC-MH to door 150m(0.65mma) 230m(0.8mma)
Chime Tone Intercom
DOOR
ROOM
1 IE-1AD(U)
1
Door station
Master station
Lineup
IF-DA
EL-12S
AC-10S
Electric door
strike
m P.97
Access control
keypad,
surface mount
m P.95
Door station
m P.30
IER-2
AC-10F
Access control
keypad,
flush mount
m P.95
TAR-3
Power supply
IE-1AD(U)
12~24V DC power supply
12~16V AC transformer
Master station
Features
External signaling
relay
m P.98
Wiring
l Chime tone intercom for 2 locations
l Door release button
l AC or DC power source
360m / 1.0mma
IE-1AD(U)
IF-DA
IER-2
2
NP
1
2
1
2
Communication network
2
2
M
EL-12S
H
IE-1AD(U)
IF-DA
AUDIO ENTRY SECURITY
Call extension
m P.97
WH
1
E
L
L
+
–
IER-2
l Run audio wires in a separate jacketed cable from door release wires.
H : AC transformer WH : White(2)
M
Specifications (IE-1AD(U))
Power source
Power supply
Communication
Unit dimensions
IF-DA
130
IE-1AD(U)
98
Door release
Wiring
210
83.5
83.5
Distance
12~16V AC, 180mA
12~24V DC, 160mA
AC transformer (for IE & EL-12S), PS-1225/S/UL.
Door calls in w/4-tone chime, adjustable. Pick up
handset to reply.
Contact rating: 24V AC/DC, 500mA
2 parallel wires, non-polarized
(+2 for EL-12S)
IE-1AD(U) to door 150m(0.65mma) 360m(1.0mma)
28
80
58
26
Chime Tone Intercom
DOOR
ROOM
3 IE-1GD(U)
1
Door station
Master station
Sub station
Lineup
IE-JA
Door station
m P.30
AUDIO ENTRY SECURITY
Power supply
IE-1GD(U)
IEH-1CD
Master station
Sub master station
AC-10S
Electric door
strike
m P.97
Access control
keypad,
surface mount
m P.95
IER-2
AC-10F
Call extension
m P.97
Access control
keypad,
flush mount
m P.95
TAR-3
External signaling
relay
m P.98
12~24V DC power supply or
12~16V AC transformer
Features
EL-12S
Wiring
l 3-station chime tone intercom with one door
l Door release button
l All call type room calling
l Chime tone cutout at sub station
l AC or DC power source
360m / 1.0mma
190m / 1.0mma
IE-1GD(U)
IEH-1CD
IEH-1CD
IER-2
IE-JA
2
M
Communication network
1
2
IEH-1CD
2
2
D1
E1
IER-2
IE-JA
IE-1GD(U)
EL-12S
M
6
6
H
T
R
C
E
T
R
C
E
T
R
C
E
L
L
L
L
L
L
1
E
+
–
IEH-1CD
l Run audio wires in a separate jacketed cable from door release wires.
H : AC transformer
All Call type calling with pretone & voice
Specifications (IE-1GD(U))
Unit dimensions
Power source
IE-1GD(U)
IEH-1CD
115
IE-JA
116
Communication
210
83.5
83.5
Door release
Wiring
10
100
27
Power supply
61
Distance
12~16V AC, 200mA
12~24V DC, 200mA
AC transformer 12~16V, 550mA (for both IE &
EL-12S), PS-1225/S/UL
Door calls in w/4-tone chime to all stations. Chime can
be cut out at sub(s). Pick up any station to reply. Press
CALL to call other inside stations with pretone & voice.
Contact rating: 24V AC/DC, 500mA
2 parallel wires to door, non-polarized.
6 wires in loop, between rooms.
IE-1GD(U) to door 150m(0.65mma) 360m(1.0mma)
Between rooms 75m(0.65mma) 190m(1.0mma)
Chime Tone Intercom
DOOR
ROOM
2
3 IE-2A2DU
Door station
Master station
Sub station
Lineup
IE-JA
Door station
m P.30
Door station
m P.30
IE-2A2DU
IE-2AD(U)
IEH-1CD
Master station, 2 door
releases
Master station
Sub master station
Features
IER-2
AC-10F
Call extension
m P.97
Access control
keypad,
flush mount
m P.95
External signaling
relay
m P.98
2 door release
12~24V DC power supply
12~16V AC transformer
Access control
keypad,
surface mount
m P.95
TAR-3
IEH-1C2D
Power supply
AC-10S
Electric door
strike
m P.97
Wiring
l 3-station chime tone intercom
l 2 door stations w/door release
l All call type room calling
l Chime tone cutout at sub station
l Door selective monitoring at master station
l AC or DC power source
360m / 1.0mma
190m / 1.0mma
IE-2A2DU
IE-JA
2
M2
IEH-1C2D
IEH-1C2D
8
IER-2
2
2
M2
1
2
IER-2
IE-JA
IEH-1C2D
8
IF-DA
1
2
Communication network
AUDIO ENTRY SECURITY
IF-DA
EL-12S
EL-12S #1
IE-2A2DU
EL-12S #2 H
D1
E1
D2
E2
T
R
C
E
T
R
C
E
T
R
C
E
L
L
L
L
L
L
BL
BL
+
–
BL
1
E
IF-DA
BL : Blue(2)
IEH-1C2D
( 1)
All call type voice calling between rooms
(*1) Available in IE-2A2DU or IE-2AD(U) w/RY-3DL
Specifications (IE-2A2DU)
Power source
Unit dimensions
Power supply
IE-JA
115
IE-2A2DU, IE-2AD(U)
Communication
83.5
10
210
83.5
83.5
210
116
IEH-1CD
130
IF-DA
98
H : AC transformer
83.5
28
Door release
Wiring
100
68
100
61
Distance
12~16V AC, 200mA
12~24V DC, 200mA
AC transformer 12~16V AC, 550mA (for both IE &
EL-12S). PS-1225/S/UL
Door calls in w/4- or 2-tone chime to all stations, 45
sec. Chime can be cut out at sub. Pick up any station
handset to reply. Press CALL to call other stations with
pretone & voice.
Contact rating: 24V AC/DC, 500mA
2 parallel wires, non-polarized.
6 wires in loop, rooms.
IE-2A2DU to door 150m(0.65mma) 360m(1.0mma)
Between rooms 75m(0.65mma) 190m(1.0mma)
28
Chime Tone Intercom
DOOR
ROOM
2
6 IE-8MD
Door station
Master station
Lineup
Sub station
AC-10S
EL-12S
Access control
keypad,
surface mount
m P.95
Electric door
strike
m P.97
IE-JA
Door station
m P.30
TAR-3
AUDIO ENTRY SECURITY
External signaling
relay
m P.98
IF-DA
Door station
m P.30
Power supply
PS-1225S PS-1225UL
PS-1820S PS-1820UL
IE-8MD
IE-8HD
6-call master
6-call sub master
RY-AC/A
External signaling
relay
m P.97
PS-1225 m P.99
PS-1820 m P.100
Features
Wiring
l Expandable to 6-station system
l Selective or All Call between inside stations
l Door select and monitor button (on IE-8MD only)
l AC or DC power source
l Selective door release control
l Chime tone cutout on inside stations, selectable
360m / 1.0mma
IF-DA
M
IE-8HD
IE-8MD
IF-DA
1
IE-8MD IE-8HD IE-8HD IE-8HD IE-8HD IE-8HD
4
IE-JA 2
M
1
2
3
M
EL-12S
IE-JA
EL-12S
M
4
IE-8HD
5
IE-8HD
H
T
6
IE-8HD
4
D1
E1
D2
E2
EL
EL
SL
SL
1
2
3
4
+
–
2
1
2
3
4
station # setting
2
4 5 6
Internal communication by Selective Call or All Call. Chime tone can be muted at
each station selectively.
IF-DA
130
210
83.5
83.5
98
Communication
28
IE-JA
115
110
116
83.5
10
79
4
3
1
2
3
4
4
1
2
3
4
5
1
2
3
4
6
1
2
3
4
3
4
5
6
4 5 6
4 5 6
4 5 6
4 5 6
Specifications (IE-8MD)
Power supply
IE-8MD
IE-8HD
4
H : AC transformer T : PS-1225/S/UL U : PS-1820/S/UL or AC transformer
Power source
Unit dimensions
4
1
1
2
IE-8HD
2
190m / 1.0mma
2
Communication network
29
AC-10F
Access control
keypad,
flush mount
m P.95
Door release
Wiring
Distance
12~16V AC, 900mA
12~18V DC, 500mA
Intercom only; 12V or 18V DC power supply.
AC transformer 12V AC, 10VA or 16V AC, 14VA w/no
load voltage 20V or less.
Intercom + EL-12S; 12V AC, 10VA only
Door calls in w/4- or 2-tone chime and LED, 45 sec.
Pick up any handset to reply. Press 1 ~ 6 to call other
station with pretone and voice or All Call. Single
channel, common talk system.
Contact rating: 24V AC/DC, 350mA
2 parallel wires, to door.
4 wires in loop, between rooms.
IE-8MD to door 150m(0.65mma) 360m(1.0mma)
Rooms 75m(0.65mma) 190m(1.0mma)
Audio Door Stations
IE/IF Series
Unit dimensions
98
AX-DM
135
IE-DC
130
IF-DA
83.5
28
100
IE-DC
IF-DA
83.5
IE-JA
34
43
IE-FY
220
83.5
128
115
116
10
160
Specifications
Audio door station
Mullion type
Wiring
Wiring distance
2 parallel wires to master, non-polarized
150m(0.65mma) 230m(0.8mma)
360m(1.0mma)
Flush mount station
IE-FY
Door station
66
Features
Used for
l Weather resistant audio door
stations
l Hands-free communication
l Call button rings chime or tone at
inside station
IE-1AD(U), IE-1GD(U),
IE-2AD(U), IE-8MD,
TD-nH/B w/DE-UR
(n=3, 6, 12 & 24)
TC-M w/TB-AD1
TC-M w/TB-AD10
AX
Some applications
AUDIO ENTRY SECURITY
AX-DM
Door station
22.5
Door station
Door station
IE-JA
160
Surface mount station
l At multiple doors
w/TB-ADM10 in place of
video door
IE-DL Series
Unit dimensions
Surface mount station
175
IE-DL1, IE-DL2, IE-DL3
IE-DL1
83.5
1-call surface-mount door
station
120
25.5
Specifications
IE-DL2
2-call surface-mount door
station
Power source
Communication
Wiring
Wiring distance
IE-DL3
3-call surface-mount door
station
12~16V AC, 140mA or 12~24V DC, 140mA
Press CALL to ring a flat station. Talk hands-free after
the inside station replies.
4 to 8 wires, polarized.
150m(0.65mma) 230m(0.8mma)
360m(1.0mma)
Features
Used for
l 1~3-call surface-mount door
station with aluminum panel.
l Directory back illumination.
l AC/DC power source.
IE-1AD(U), IE-1GD(U),
IE-2AD(U), IE-2A2D(U),
IE-8MD, TD-nH/B w/DE-UR
(n=3, 6, 12 & 24)
30
Hands-free Color Video BUS Apartment System
The GH system is Hands-free Color video apartment system employing 1pair for Audio & 1pair for video connections.
The resident can easily identify visitors by crisp "Color image" together with convenient "Hands-free communication."
The GH system configures basically two systems: Standard 48-station, Expanded 500-station systems. Apartment
station is selectable out of three types: Color monitor hands-free station (w/optional handset), B&W monitor hands-free
station, and hands-free audio station. Entrance station is of a fully modular design with vandal-resistant zinc die-cast
panel. The GH system is totally flexible, allowing you to mix-and-match components to create the exact system
configuration and features needed for each application.
Capacity
Standard
Expanded
48 500
Apartment station
MULTI-UNIT ENTRY SECURITY
• Identify visitors by crisp "COLOR" image
• Convenient "Hands-free communication"
• Up to 4 apartment stations can be linked
per Residence (max. 2 monitor stations)
• Monitoring an Entrance camera
from Apartment monitor station
• Add an external signaling device to Apartment station
• Call tone off at individual station with LED indicator
• Doorbell at individual door
• Auto-Entry (Doctor call)
• User-optional feature using SERVICE button,
such as turning on/off light, elevator control, etc.
• Panic call transfer to security guard station
Color monitor hands-free station
B&W monitor
hands-free station
Audio
hands-free station
Color monitor
hands-free station
with optional handset
* The design and specifications are subject to change without notice for improvement.
31
Apartment Station
Simple and easy installation
• Two single-pair BUS for audio & video
• Easily links Entrance station to
Apartment station
• Resident names & room numbers etc.
are programmable by PC
Entrance station
Security guard station
Standard
Expanded
5 16
Entrance station
• Vandal-resistant zinc die-cast panel
• Sleek & compact semi-flush design
• Digital name scrollings
- Search resident names and room numbers
using keypad
- Customer programmable welcome messages
- Names & welcome messages are selectable
from 5 different languages
(English, French, Spanish, German & Dutch)
Standard
Expanded
2
4
Security guard
station
• Communicate with all residents and Entrance stations
• Receive all Entrance station call-in
(Reception mode function)
• Absence call-in memory stored with Callback
• Receive panic calls from Apartment stations
MULTI-UNIT ENTRY SECURITY
Capacity
Capacity
32
Hands-free Color Video Bus Apartment System
System Configuration
Standard system
Divided cabling
with GH-4Z
Trunk line No.1
5 Entrance stations
2 Security guard stations
48 Residential stations
Monitor to monitor
cabling
Trunk line No.6
1Px2
1Px2
On the same trunk line, do not
have two wiring methods mixed,
Divided cabling with GH-4Z &
Monitor to monitor cabling
1Px2
1Px2
1Px2
GH-4Z
1Px2
1Px2
GH-1KD
GH-1KD
GH-1MD
1Px2
GH-1KD
GH-1KD
1Px2
1Px2
1Px2
1Px2
GH-4Z
1Px2
GH-1KD
GH-1KD
GH-1MD
1Px2
GH-1KD
1Px2
1Px2
GH-1KD
1Px2
1Px2
MULTI-UNIT ENTRY SECURITY
1P
1Px2
1Px2
GH-4Z
Doorbell
GH-1KD
Doorbell
GH-1MD
1Px2
GH-1KD
+
GH-HS
GH-1AD
GH-1KD
GH-1KD
GH-1AD
Apartment
No.2~5
300m / 0.8mma
1Px2
150m / 0.8mma
1Px2
1Px2
PS24
1P
1P
GH-BC
PS24
1P
Entrance Station : Max. 5
Wiring distance: Entrance station - Bus & Video control unit 300m
Video control unit - Farthest Video Apartment station 150m
(Expandable with additional Video control unit)
Bus control unit - Farthest Audio Apartment station 300m
Accumulated total Audio wiring distance 2,500m
33
1P
GH-VBC
PS24
1P
1P
PS24
1P
1P
GH-MK
GH-MK
Security Guard Station : Max. 2
Expanded system
16 Entrance stations, 2 common trunk lines (8 each per common line)
4 Security guard stations, 2 common trunk lines (2 each per common line)
500 Residential stations, 4 sub trunk lines (125 each per sub trunk line)
Trunk line
No.1
No.6
No.1
Apartment
station
Max.125
/SUB line
No.6
Apartment
station
Max. 125
/SUB line
1Px2
No.2~5
1Px2
GH-BC
PS24
1Px2
1Px2
1Px2
1Px2
GH-VBC
PS24
1Px2
No.2~5
GH-BC
PS24
1Px2
GH-VBC
PS24
300m / 0.8mma
1Px2
SUB 1A
SUB 2B
COMMON 1
COMMON 1
1Px2
1P
1Px2
1P
1P
1P
1P
GH-BCX
PS24
GH-BC
PS24
1Px2
1P
GH-VBX
1P
GH-BC
PS24
COMMON 2
1P
1P
PS24
1P
1P
GH-MK
GH-MK
Security Guard Station
Max. 2/COMMON line
Entrance Station
Max. 8/COMMON line
COMMON 2
1Px2
1P
PS24
PS24
150m / 0.8mma
1P
MULTI-UNIT ENTRY SECURITY
SUB 1B & 2A
1Px2
1P
PS24
Entrance Station
Max. 8/COMMON line
1P
1P
GH-MK
GH-MK
Security Guard Station
Max. 2/COMMON line
Wiring distance: Entrance station - Expanded Bus & Expanded Video control unit 300m
Expanded Video control unit - Farthest Video Apartment station 150m
(Expandable with additional Video control unit)
Expanded Bus control unit - Farthest Audio Apartment station 300m
Accumulated total Audio wiring distance 2,500m/SUB line
34
Hands-free Color Video Bus Apartment System
Entrance station
Direct-select call button
Digital name scrolling
The directory button panels back-lit
display illuminates resident's name
or unit number
Color camera
VFD Display
Directory scroll/
Cancel/ Call buttons
Zinc die-cast panel
Keypad illumination
Audio module
Access control/
room number
dialing keypad
In-use LED
Call button
Directory card &
cover
Audio Module
MULTI-UNIT ENTRY SECURITY
GH-DP
Audio panel
Digital name scrolling module
GH-DA
Audio module
GF-NSP
GH-NS
Display module panel
Digital name scroll
display module
Front frame & back box
Camera Module
GF-2F
2-module front frame
GF-VP
GH-VA
GF-10KP
Camera panel
Camera module
GH-10K
10-key module panel
10-key module
GF-3F
3-module front frame
Call switch Module
GF-1P
GF-2P
1-call panel
2-call panel
GF-2B
2-module back box
GF-3P
3-call panel
GF-4P
4-call panel
3-module back box
Call switch module
Option
35
GF-3B
GH-SW
Access control keypad module
GF-AP
GH-AD
GF-BP
GF-AC
Address panel
Address module
Blank panel
Access control
keypad module
Specifications (GH-DA,GH-VA)
System layout example
Wiring
Type of cable
Direct-select call button
1P
l Searches of resident names and room
number using the keypad
l Customer programmable welcome
messages can also be shown in 5
different languages
(English, French, German, Spanish
& Dutch )
l White LED illuminator truns on in low-light
conditions
1P
#2
1P
#1
1P
Mounting
H
GH-BC
M
Housing
N
H
Specifications (GH-SW,GH-10K,GH-AD)
M
Lighting
Housing
GH-VBC
N
Digital name scrolling
1P
1P
1P
#1
1P
Yellow LED
Fire-retardant plastic
Specifications (GH-NS)
1P
#2
Two single-pair cable common
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm dia.~1.0mm
dia.
Box and front frame GF-2B,3B
and GF-2F,3F
Fire-retardant plastic
Power source
1P
1P
1P
Housing
N
24V DC, supplied by
PS-2410LD, LC
Fire-retardant plastic
GH-BC
N
GH-VBC
N
Unit dimensions
GH-DA
GF-VP
95.2
GH-VA
93
49.5
108
15.8
52.3
4.5 38
105.6
GH-NS
GF-10KP
14.4
9.9
28.9
38
9
14.4
110
106.2
110
GF-2B
GF-3F
GF-2F
GH-10K
95.2
95.2
100.3
GF-NSP
88.3
110
GF-nHBA
108
110
88.3
Rain hood
95.2
GF-nHA
7.9
51
GH-SW
GF-4P
4.5 38
106.2
GF-3B
MULTI-UNIT ENTRY SECURITY
93
7.9
95.2
GH-DP
110
Surface-mount box
295
200
320
16
135
16
110
44
135
42
GF-202HBA
110
85
GF-202BA
22
4-call
44
61
229
243
243
GF-202HA
290
290
274
65
45
AIPHONE
320
Audio/Video + Name scroll
225
GF-nBA
225
Hooded surface-mount box
AIPHONE
270
135
16
16
44
44
36
Hands-free Color Video Bus Apartment System
Entrance station components
Number of calling button
4.
8.
12.
AIPHONE
AIPHONE
16.
AIPHON E
20.
AIPHON E
24.
25.~48.
AIPHONE
AIPHONE
GH-NS, GF-10K
AIPHON E
AIPHON E
GH-VA
GF-VP
GH-DA
GH-DP
GH-SW
GF-4P
GF-2F
GF-2B
GF-3F
GF-3B
GF-BP
GH-AD
GF-AP
GH-NS
GF-NSP
GH-10K
GF-10KP
(1)
(2)
(3)
(4)
(5)
(6)
(7)
1
1
1
1
1
1
1
1
-
1
1
1
1
2
2
2
2
-
1
1
1
1
3
3
2
2
-
1
1
1
1
4
4
2
2
-
1
1
1
1
5
5
3
3
1
1
1
1
1
6
6
3
3
1
-
-
1
-
1
-
-
-
-
-
-
-
-
1
1
1
1
1
1
1
1
2
2
-
For more than
7 GH-SW, install
additional power
supply & special
device required.
Contact local
AIPHONE distributor
(1) Camera (2) Audio (3) Call switch (4) 2-module Front frame (5) 3-module Front frame (6) Option (7) Digital name scroll
Interconnecting Modules with Plug-in Conectors
Mounting
42
W
GF-3B
GH-DA
GH-DP
GF-3F
. GF-nHBA
. GF-nHA
(4)
H
W
. GF-202BA
85
H
W
61
H
CN3
MULTI-UNIT ENTRY SECURITY
H
(3)
GH-SW
GF-4P
(5)
(2)
(1)
CN1
45
65
22
W
H
W
GF-102HA/HBA 243 155
GF-102BA 229 139
GF-202HA/HBA 243 290
GF-202BA 229 274
GF-103HA/HBA 338 155
GF-103BA 324 139
GF-203HA/HBA 338 290
GF-203BA 324 274
GF-303HA/HBA 338 425
CN1
CN2
CN2
CN1
CN1
CN2
CN2
CN1
(1) Tamper-proof screw & screwdriver (supplied with GH-BC) (2) Module-mounting bracket (supplied with
GF-3F) (3) Internal wiring connector (4) Joint pipe(x2) (5) Cut out openings in advance.
Back box
1.
GH-VA
2.
(1)
(1)
3.
200
mm
295
mm
25mm
25mm 25mm
44mm
W
(2)
W
44mm
(2)
1. Two 2-module back boxes
2. Three 3-module back boxes
(1) Joint pipe(x2) (2) Do not recess back box more than 15mm.
GF-2B/3B
x1
x2
x3
x4
x5
x6
x7
x8
x9
W
110
245
380
515
650
785
920
1055
1190
GH-NS
CN3
CN1
CN3
CN1
CN2
GH-DA
GH-10K
3. Back box total width (mm)
Adjust camera angle
• Viewing from initial
camera position
95cm
• Changing camera angle
• Image view area
GH-VA
★
Camera
center
GH-VA
65cm
★
50cm
★
24cm
GH-VA
GH-VA
65cm
★
1. Open the rubber cap.
2. Change the camera angle with the lever
113cm
113cm
★
★
24cm
★
*Do not forget to replace the cap.
50cm
★
37
approximate
When adjusted
to the left
When adjusted
to the right
Residential station
Features
GH-1KD
GH-1KDS
(white)
(silver)
Color monitor apartment station
• Selectable 3 types of stations (Color monitor, B&W monitor, or Audio only)
• Hands-free communication, auto-voice actuation
• Press-talk operation available
• Max. 4 apartment stations can be linked per Residence (max. 2 monitor stations)
• Monitoring a Video entrance station (audio & video)
• Call tone cutout with LED indicator
• Security guard call
• Additional handset available for GH-1KD
• Option
External signaling device to Apartment station (w/GH-RY)
Doorbell at individual door with different call tone
Auto-Entry (Doctor call), door strikes automatically opens by pressing the Call button at the
entrance station. (Not available to use together with entrance light feature)
-Panic call, call an Emergency to the Security guard station(s) by panic call button
User-optional device can be controlled with SERVICE button, such as
-Light on and off at entry way to elevator
-Elevator control, goes down to the ground floor or up to resident floor
Not available GH-1MD
Functions
Specifications (GH-1KD, GH-1MD, GH-1AD)
Buzzer
Apartment station
24V DC, supplied from
Bus control units,
GH-BC & GH-VBC
Panic alarm
Cal
ling
&C
Do
or r
om
ele
mu
Mo
nic
nito ase
atio
rin
n
g (a
udi
o/
vid
eo)
B&W monitor apartment station
ory
em
n
larm
g m atio
ic a callin unic
Pan
ce
mm
Co
sen
Ab ng &
li
Cal
GH-1MD
O
Video monitor
GH-1KD: 3.5 inch
color LCD
GH-1MD: 4 inch B&W CRT
Wiring
GH-1KD, GH-1MD:
Two Single –pair cables
common
GH-1AD:
Single-pair cable common
Mounting
Wall-mounting only
Housing
Fire-retardant plastic
PANIC CALL switch
Doorbell
Calling & Communication
Door release
Monitoring (audio)
Reception mode function
Entrance station
Security guard station
Trunk line
Unit dimensions
Audio apartment station
Monitor to
monitor cabling
Divided cabling with GH-4Z
175
GH-1KD
GH-1AD
1Px2
1Px2
1Px2
125
32
GH-1MD
210
1Px2
MULTI-UNIT ENTRY SECURITY
Power source
External signaling
GH-1KD
GH-1KD
GH-1KD
1Px2
GH-4Z
160
55.5
GH-1AD
Only available to connect
on a trunk line with
GH-4Z used
GH-HS
Option handset for GH-1KD
175
1Px2
GH-1AD
GH-1KD
1Px2
125
32
GH-HS
On the same trunk line do not
have two wiring methods mixed,
Divided cabling with GH-4Z &
Monitor to monitor cabling
140
GH-1MD
1Px2
177
1Px2
45
46
38
Hands-free Color Video Bus Apartment System
Security guard station
Features
Unit dimensions
GH-MK
Security guard station
GFW-S
Desk-top stand
60
83.5
210
l Call to residential station
GH-MK
l Digital display shows name of resident &
room number
l Monitoring a Video entrance station (audio)
l Receive all Entrance station call-ins
(Reception mode function)
215
69
l Absence call-in memory stored with Callback
l Option
Specifications (GH-MK)
Doorbell at door with different call tone
User-optional device can be controlled with Power source 24V DC, supplied by
PS-2410LD, PS-2410LC
SERVICE button, such as
Max. 16 letters for names; English,
VFD display
-light on and off at entry way to elevator
French, German, Spanish & Dutch
l Receive a Panic call from apartment station
Wiring
Type of cable
2 single-pair cables
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm dia.~1.0mm dia.
Mounting
Wall-mounting or Desk-top
mounting on GFW-S
Fire-retardant plastic
Housing
Control units
System layout example
1P(Audio)
1P(Video)
BUS (Audio/Video) MAX.6
Monitor to monitor
cabling
Divided cabling with GH-4Z
1
2
3
4
5
6
150m
Expand pos.
1Px2 1Px2
GH-4Z
GH-1KD
GH-1KD
GH-1KD
EXP
GH-1KD
GH-VBC
GH-1KD
GH-BC
Bus control unit
STD
max. 2
On a single trunk line, do not have
two wiring methods mixed,
Monitor to monitor & Divided cabling
with GH-4Z
GH-BC
GH-VBC
PS24
PS24
150m
MULTI-UNIT ENTRY SECURITY
GH-1KD
PS24
GH-BC GH-VBC
PS24
1Px3
PS24
PS24
EXP
STD
Standard pos.
Wiring distance
GH-VBC
Video Bus control unit,
expander video control
GH-BC, GH-VBC to Farthest Entrance station
GH-BC, GH-VBC to Farthest Video apartment station
GH-BC, GH-VBC to Farthest Audio apartment station
GH-BC, GH-VBC to each Power supply
GH-RY to Entrance station
Accumulated Audio lines (R1, R2) Total wiring distance
Distance (Diameter of wires)
300m(0.8mm)
150m(0.8mm) Expandable 150m
with additional GH-VBC & Power supply
300m(0.8mm)
5m(0.8mm)
300m(0.8mm)
2,500m(0.8mm)
Type of Cable
2-conductor cables solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia.
Specifications (GH-BC, GH-VBC)
Unit dimensions
Power source
GH-4Z
Consumption
Wiring
Housing
108.5
Video 4-zone divider
GH-BC,
GH-VBC,
GH-4Z
122.5
39
24V DC, supplied by
PS-2410LD, PS-2410DIN
900mA.
Single-pair cable common
Fire-retardant plastic
Specifications (GH-4Z)
61
Wiring
Mounting
Housing
Two Single-pair cables common
DIN rail
Fire-retardant plastic
Expanded control units
Features
l Expandable to max. 500 Apartment stations, 16 Entrance stations, and 4 Security guard stations
System layout example
GH-1KD
GH-BCX
Expanded Bus control unit
GH-BC
GH-VBC
PS24
PS24
GH-1KD
GH-BC
SUB1B SUB2A
1Px2
SUB1A
PS24
1Px2
GH-VBC
PS24
SUB2B
1Px2 COMMON 1
COMMON 1
PS24
PS24
GH-BCX
GH-VBX
PS24
1Px2 COMMON 2
PS24
GH-MK
COMMON 2
GH-MK
GH-MK
GH-MK
PS24
GH-BC
GH-BC
PS24
PS24
l COMMON trunk line: Requires one each of GH-BC & Power supply
l COMMON trunk line: Max. 8 Entrance stations & 2 Security guard stations
l SUB COMMON trunk line: Max. 125 Apartment stations
GH-VBX
Expanded video control unit
Specifications (GH-BCX, GH-VBX)
Unit dimensions
GH-BCX, GH-VBX
Power source
108
PS-2410LC. GH-VBX: Supplied from GH-BCX
Wiring
Single-pair cable common
Mounting
DIN rail
Housing
Fire-retardant plastic
Power supply
Unit dimensions
Specifications
PS-2410LD
PS-2410LC
Power supply
PS-2410LD
PS-2410LC
Power source
220-240V AC
120V AC
164
Secondary output voltage & current
24V DC, 1A
24V DC, 1A
66
95
RD
BK
RD : Red, BK : Black
PS-2410LD
MULTI-UNIT ENTRY SECURITY
61
210
GH-BCX: 24V DC, supplied by PS-2410LD,
PS-2410LC
Option
GH-RY
External signaling relay
entrance light, external buzzer
W-DIN11
AC-10S
AC-10F
DIN mounting rail
for GH-BC, GH-VBC, GH-4Z
Access control
keypad,
surface mount
m P.95
Access control
keypad,
flush mount
m P.95
40
Hands-free Color Video Bus Apartment System
GH Lift control adaptor
Features
l Lift is controllable from apartment station while communicating with
entrance station.
When door release button is pressed, electric door strike is activated and
simultaneously output signal is transmitted to the lift controller or the access
controller. The access is authorised only to the floor of communicated
apartment station.
l Selectable dry contact: Normally Open or Normally Closed
l System set up data is programmable on your PC
GHW-LC
Lift control adaptor
* GH-BCX/A & GH-DA/A is required to use GHW-LC.
Functions
Cabling
1P(Audio)
1P(Video)
1P
n
tio
ica
GH-1KD
un
eas
e
mm
rel
Co
or
Do
cti
g&
ea
(on
Access authorised
only to the floor
of communicated
apartment station
)
Ca
on
llin
ol
ntr
Co
MULTI-UNIT ENTRY SECURITY
GH-1KD
GH-VBC
GH-BC
PS24
PS24
Entrance station
Lift
Connection with GHW-LC, Lift control unit
GH-VBX
Unit dimensions
GH-BC
GH-BCX
PS24
PS24
Distribution
point
GHW-LC
GH-BC
PS24
PS24
108
GH-BC
PS24
210
61
GHW-LC
Specifications
Power source
Relay
Wiring
Mounting
Housing
Supplied by GH-BC
Output
20
Contact rating 24V AC/DC, 0.5A
N/O or N/C dry contact
Operating time From 1 to 600 seconds
Single-pair cable
DIN rail
Fire-retardant plastic
PS24
Lift controller
GH Expanded system
PS24 :PS-2410LD,
41
PS-2410LC
Lift
*Not available in Europe
GH CCTV camera interface adaptor for Reception
Features
Tenant can receive a call from concierge with visitor’s picture image through
CCTV camera.
In luxurious condominium, concierge receives all visitors directly instead of
using the entrance station. In case concierge asks the tenant to verify the
visitors, GH-CCTV allows GH-MK to call apartment station with the image from
CCTV transferred. The tenant can communicate with concierge while the
picture of visitor displayed at the apartment station.
Monitoring the CCTV camera is also available from the apartment station.
GH-CCTV
CCTV camera interface
adaptor for Reception
Functions
Cabling
1P(Audio)
1P(Video)
1P
CCTV camera
Video
CCTV camera
Coaxial cable
Power
supply
GH-1KD
n
g
llin
Ca
tio
1P
Monitoring only
a
nic
m
u
1P×2
m
Co
1P
GH-CCTV
1P
CCTV camera
Coaxial cable
1P
GH-MK
Power
supply
Unit dimensions
MULTI-UNIT ENTRY SECURITY
Monitoring (Video)
1P×2
GH-CCTV
GH-BC
PS
GH-VBC
PS
205
GH-CCTV
1P×2
340
93
PS24
Specifications
Power source
Video signal
Mounting
Supplied by GH-BC & GH-VBC
NTSC 1V P-P
75d
Desk-top or wall-mounting
GH-MK
Parking lot
PS24 :PS-2410LD,
PS-2410LC
42
Hands-free Color Video Bus Apartment System
Cabling
1P(Audio)
1P(Video)
1P
Standard system
Capacity
5 Entrance stations
2 Security guard stations
48 Residential stations
Monitor to monitor cabling
Divided cabling with GH-4Z
Trunk line No.2
1Px2
Trunk line No.1
1Px2
Doorbell
1Px2
GH-4Z
1Px2
GH-1KD
1Px2
1Px2
1Px2
1Px2
1Px2
1P
1P
1Px2
GH-4Z
Doorbell
Doorbell
Doorbell
Doorbell
GH-1KD
GH-1KD
GH-1KD
GH-1MD
MULTI-UNIT ENTRY SECURITY
GH-1MD, unlike GH-1KD,
is only available to connect
on a trunk line
with GH-4Z used
1Px2
GH-1AD
GH-1AD
GH-1KD
Max. 4 apartment stations can be linked per Residence
(including max. 2 monitor stations)
1Px2
On the same trunk line, do not have two wiring methods mixed,
Monitor to monitor & Divided cabling with GH-4Z
1Px2
Trunk line
No. 3 to 6
1Px2
Distribution
point
R1
PS24
R2
PS24
GH-BC
GH-VBC
1Px2
Light control
Timer
Entrance
No. 2 to 5
GH-RY
1Px2
1P
1P
AC
1P
Light
PS24
Door release
Doorbell
PS24
GH-MK
Entrance station
Security guard station
Cable: 1P x 2, 2-conductor cable solid copper & non-braided, polyethylene insulation
43
Wiring
Monitor to monitor cabling
Divided cabling with GH-4Z
Trunk line No.2
Trunk line No.1
GH-4Z
A
B
R1 R2 B1 B2
GH-1KD
OUT
B1
B2
R1 R2 B1 B2
LINE OUT
B1
B2
OUT 3
OUT 4
R1
R2
1Px2
B1
IN
B2
OUT
IN
R1
R2
R1
R2
C
CE
A
B
Terminate
the last GH-4Z
1Px2
B1
B2
R1
R2
A
IN
IN
B1
B2
OUT 1
R1
R2
B1
B2
OUT 2
R1
R2
LINE IN
R1 R2 B1 B2
R1
R2
C
CE
GH-1MD
R1
OUT
R2
R1
OUT
R2
R1
IN
R2
C
CE
R1
IN
R2
C
CE
GH-1AD
GH-1AD
Doorbell
1Px2
R1
OUT
R2
R1
IN
R2
C
CE
A
B1
OUT
B2
1Px2
B1
B2
R1
OUT
R2
B1
IN
B2
B
1Px2
B1
IN
B2
B1
OUT
B2
1Px2
GH-4Z
Doorbell
B1
OUT
B2
Doorbell
Door
bell
1Px2
B
R1
IN
R2
C
CE
A
B
GH-1KD
B1
OUT
B2
GH-1KD
B1
IN
B2
B1
IN
B2
R1
OUT
R2
R1
OUT
R2
R1
IN
R2
C
CE
R1
IN
R2
C
CE
A
Door
bell
B
A
B
GH-1KD
GH-1KD
1Px2
GH-BC
R1
R2
Distribution
point
MULTI-UNIT ENTRY SECURITY
Trunk line
No. 3 to 6
1Px2
+
-
+
-
+
-
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
Power supply
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6
IN1
AC
IN2
IN3
IN4
AC
Power supply
IN5
A1 A2 A1 A2 A1 A2 A1 A2 A1 A2
+
-
EXP
STD
Video Entrance station No. 2 to 5
Light control
Timer Orange
Blue
1Px2
GH-MK
1P
Orange GH-RY White
Light
GH-DA
Doorbell
CN2
R1 R2 ELB ELC ELM RY RY
CN1
A1 A2
CN3
+
GH-VA
GH-NS
CN1
+
CN3
-
AC
+
-
AC
-
CN100
R1
R2
R1
R2
R1
R2
C
CE
+
-
R1
R2
C
CE
+
-
Power supply
Power supply
GH-10K
2nd
GH-MK
SW1
SW1
Entrance station
Apartment station and Security guard station have following options
GH-1KD, GH-1MD, GH-1AD
l Doorbell
l Panic alarm switch
l User-optional device*(not available with GH-1MD)
l External buzzer*(used w/GH-RY)
l Doctor call*
Doorbell button
*Option connector cable is required.
Contact local AIPHONE distributor
locally available
R1
R2
C
CE
K
KE
••
••
••
Option connector cable
User-option device
External buzzer
Doctor call
GH-MK
l Doorbell
l User-optional device*
l External buzzer*
(used w/GH-RY)
R1
R2
C
CE
••
••
••
Option connector cable
User-option device
External buzzer
Doorbell button
Panic Call switch
(w/break contact)
locally available
*Option connector cable is required.
Contact local AIPHONE distributor
44
Two-Wire Bus System
ENTRANCE
5
RESIDENCE
100or250 GF Audio
Entrance station
Entrance station modules
l Direct-select Call Button
l Digital Name Scrolling
l Audio Module
l Direct-Select Keys
GF-DP
GF-1P
GF-2P
Audio panel
m P.49
1-call panel
m P.49
2-call panel
m P.49
GF-DA
GF-3P
GF-4P
Audio module
m P.49
3-call panel
m P.49
4-call panel
m P.49
Audio, Digital keypad, LCD Directory
& address panels
Audio, 4-call
Audio, 16-call with address panel
l Access control
keypad module
Frame & Box
Assemble the following in as many rows as required.
GF-2F 2-module Front frame
GF-2B 2-module Back box
GF-3F 3-module Front frame
GF-3B 3-module Back box
GF-SW
GF-AC
Access control
keypad module
m P.49
PP.50
MULTI-UNIT ENTRY SECURITY
Features
Call switch module
m P.49
Communication network
l Fully modular Entrance station. Vandal-resistant construction
l Two-wire Bus throughout system
l One or two apartment stations
l Call tone off at individual station with blinking LED indicator
l Door release & external light, Bus line-controlled
l User options: Doorbell at individual door. Auto-Entry (auto door
strike)
l User-optional feature using SERVICE button
GF-1DK GF-1DK
GF-1DK
Capacity
l 1 or 2 apartment stations within a residence
l Entrance station panel : 100-call sized
l Direct-select call button : Total 150 apartment stations incl. second stations
l Digital name scrolling : Total 250 apartment stations incl. second stations
GF-1DK
O
1.
GF-MK
1
A
2
B
C
D
3
E
G
4
H
5
I
J
K
L
M
PQ
8
R
T
U
F
6
N
7S
O
9Z
WX
V
Y
0
1.
M
GF-MK
2.
1
A
2
B
C
D
G
5
I
J
K
L
M
PQ
V
O
9Z
WX
T
U
F
6
N
8
R
3
E
4
H
7S
Y
0
2.
5.
J Calling & Communication K PANIC CALL sounding & Answer-back.
GF-MK; Concierge station must be used w/GF-1DK.
I Doorbell O PANIC CALL switch used for GF-1DK only
Bus line-controlled; M Door Release L External light
45
l Digital Name Scrolling
Apartment station
Concierge station
Bus control unit
Lineup
GF-NSP
LCD directory panel
m P.49
GF-BC
Bus control unit
m P.52
GF-nHA
GF-nHBA
Rain hood
m P.50
Hooded surfacemount box
m P.50
GF-nBA
GF-AP
GF-NS
LCD directory
m P.49
Address panel
m P.49
Power supply
Concierge station
m P.51
Apartment station
m P.51
Digital keypad panel
m P.49
GF-AD
GF-BP
GF-MK
GF-1D
GF-10KP
Surface-mount
box
Blank panel
m P.49
Address module
m P.49
GFW-LD
GFW-S
GF-1DK
Concierge call
apartment station
w/Panic call transfer
Use with GF-MK
m P.51
GF-10K
Digital keypad
m P.49
PS-2410LD
m P.52
m P.52
Desk-top stand
for GF-MK
m P.51
Wiring
2.BUS
2.BUS
1P
1P
GF-1DK
GF-1DK
GF-1DK x 2
1P
1P
1P
R1
R2
GF-1DK
1P
1P
GF-1DK
1P
1P
GF-1DK
R1 x 2
R2
GF-1DK
1P
1P
1P
R1
R2
1P
1P
C
CE
C
CE
R1
R2
R1 GF-1DK
R2
1P
1P
C
CE
C
CE
O
K
KE
1P
1.BUS
1.BUS
3.BUS
C
CE
O
MULTI-UNIT ENTRY SECURITY
Cabling
Long distance
adaptor
m P.53
PS-2410LC
GF-BC
1P
1P
(NP)
1P
(NP)
1P
(NP)
R1, R2
1P
1P
1P
R1
R2
1P
R1
R2
1P
R1 +
R2 –
1P
R1 R1
R2 R2
1
M
PQ
L
PQ
V
O
9Z
WX
T
WX
T
U
F
6
N
8
R
3
E
J
M
G
J
l Bus line: Any number per system. Max. 50 stations per line.
1P, Non-polarized
D
G
GF-MK
C
5
I
K
7S
Y
0
GF-MK
L
H
ML
H
B2C
K5L
E3F
N6O
Y9Z
WX
B
4
H
O
Y
U8V
T
2
F
6
9Z
PQ
1
3
A
D
L
N
V
0
2.GF-MK
M
C
E
K
U
0
R7S
J
A
2
B
5
I
8
R
H4I
G
1P
1
4
H
7S
EL
EL
+
b
A
EL
EL
+
b
1P
N
D
GF-BC
N
1P
1P
1.GF-MK
M
l Bus line (MAX.) 50 stations per Line
l K, KE terminals; Mounted on GF-1DK only
l For controlling light at the entrance, use Aiphone's MAW-B, which provides dry
closure contact.
N : PS-2410LD, PS-2410LC
46
Four-Wire Common Video System
ENTRANCE
5
RESIDENCE
100or250 GF Audio/Video
Entrance station modules
Entrance station
l Direct-select Call Button
l Digital Name Scrolling
l Camera Module
l Audio Module
l Direct-Select Keys
GF-VP
GF-DP
GF-1P
GF-2P
Camera panel
m P.49
Audio panel
m P.49
1-call panel
m P.49
2-call panel
m P.49
GF-VA
GF-DA
GF-3P
GF-4P
Camera module
m P.49
Audio module
m P.49
3-call panel
m P.49
4-call panel
m P.49
l Audio Module
Audio, Camera & Digital Keypad &
LCD Directory
Audio, Camera & Direct-select
12-call buttons
Frame & Box
Assemble the following in as many rows as required.
GF-2F 2-module Front frame
GF-2B 2-module Back box
GF-3F 3-module Front frame
GF-3B 3-module Back box
PP.50
MULTI-UNIT ENTRY SECURITY
Features
l Access control keypad module
GF-SW
GF-AC
Access control keypad module
m P.49
Call switch module
m P.49
Communication network
l Fully modular Entrance station. Vandal-resistant construction
l Two single-pair cables run throughout system
l Second monitor or audio station can be installed
l Call tone off at individual station with blinking LED indicator
l Door release & external light, Bus line-controlled
l Optional functions: Doorbell at individual door. Auto-Entry (auto
door strike)
l User-optional feature, using SERVICE button
GF-1MDK x 2
GF-1MDK
Capacity
l 1 or 2 apartment stations within a residence
l Entrance station panel : 100-call sized
l Direct-select call button : Total 150 apartment stations incl. second stations
l Digital name scrolling : Total 250 apartment stations incl. second stations
GF-1MDK
O
1.
M
1
A
2
B
C
D
G
5
I
J
K
L
M
PQ
O
9Z
V
WX
T
U
F
6
N
8
R
3
E
4
H
7S
Y
0
2.
GF-MK
5.
1
A
2
B
C
D
G
5
I
J
K
L
M
PQ
V
O
9Z
WX
T
U
F
6
N
8
R
3
E
4
H
7S
Y
0
GF-MK
J Callig & communication K PANIC CALL sounding & Answer-back.
GF-MK; Concierge station must be used w/GF-1MDK.
I Doorbell O Panic call switch, available with GF-1MDK only
Bus line-controlled; M Door Release L Light
47
Apartment station
l Digital Name Scrolling
Concierge station
Bus control unit
Lineup
GF-BC
Bus control unit
m P.52
GF-NSP
LCD directory
panel
m P.49
GF-nHA
GF-nHBA
Rain hood
m P.50
Hooded surfacemount box
m P.50
GF-nBA
Surface-mount
box
GF-AP
GF-NS
LCD directory
m P.49
GF-VBC
GF-4Z
Video control unit
m P.52
4-apt. Bus junction unit
m P.52
Address panel
m P.49
Power supply
GF-1MD
GF-10KP
Apartment station
GF-MK
Digital keypad
panel
m P.49
GF-1MD-SW
Concierge station
m P.51
w/Service button
m P.51
GF-AD
GFW-S
Desk-top stand Address module
m P.49
for GF-MK
m P.51
GF-1MDK
Concierge call apartment
monitor station
w/Panic call transfer
Use with GF-MK
m P.51
GF-10K
Digital keypad
m P.49
PS-2410LD
Blank panel
m P.49
m P.52
Wiring
1.BUS
2.BUS
GF-1MDK
1P x 2
SW1
A
GF-1MDK (x 2)
OUT
B
IN
B1 B2
B1 B2
R1 R2
R1 R2
OUT
IN
C CE
K KE
O
GF-1MDK
1P x 2
2
OUT
SW1
O
B
A
IN
R1 R2
R1 R2
OUT
IN
C CE
K KE
O
2
SW1
GF-1MDK
1P x 2
B1 B2
B1 B2
OUT
B
A
IN
B1 B2
B1 B2
R1 R2
R1 R2
OUT
IN
C CE
K KE
O
GF-1MDK
2
OUT
SW1
GF-1MDK
B
A
IN
R1 R2
R1 R2
B1 B2
B1 B2
OUT
IN
C CE
K KE
O
1P x 2
GF-1MDK
VIDEO
MULTI-UNIT ENTRY SECURITY
Cabling
GF-BP
PS-2410LC
m P.52
AUDIO
1.BUS
2
GF-VBC
1. ~ 6. BUS(Video)
6
1P x 2
VIDEO
1P x max.6
VIDEO
AUDIO
AUDIO
(1)
1P
1P
1
A
2
B
G
J
L
1P
1
C
5
I
K
L
M
PQ
8
R
V
O
9Z
WX
T
U
F
6
N
7S
3
E
4
H
J
WX
T
Y
2
B
O
9Z
G
PQ
V
0
D
M
U
F
6
N
8
R
A
5
I
K
7S
3
E
4
H
Y
+ B1B2 B1B2 B1B2 B1B2 B1B2 B1B2
– OUT6 OUT5 OUT4 OUT3 OUT2 OUT1
N
+
–
GF-VBC
IN4
IN3
IN2
R1, R2
IN1
N
2.GF-MK
R1 R1
R2 R2
GF-MK
A1A2 A1A2 A1A2 A1A2 A1A2
1
2
B
4
H
C
K
L
PQ
8
R
V
O
9Z
WX
T
U
F
6
N
7S
3
E
5
I
M
N
N
IN5
R1 +
R2 –
GF-BC
1
J
N
+
N
0
2
G
GF-BC
3
D
GF-VBC
4
A
1P x 2
C
D
1P x 2
5
Y
0
GF-MK
GF-MK
A1A2
R1 R2
GF-DA
Audio/Video trunk lines
l There are methods of installing audio/video trunk lines, i.e. Monitorto-Monitor or homerun to GF-4Z’s. The two methods may be used
within a system. But do not mix two methods on a same trunk line.
l BUS (Audio/Video) Line; Up to 6 lines. Two single-pair cables
common. Max. 25 Monitors per Line.
A1A2
R1 R2
GF-DA
(1) Required when the second GF-1MDK is installed within an apartment.
l K, KE terminals for Panic call switch; GF-1MDK only.
l For controlling light at the entrance, use Aiphone's MAW-B, which provides dry
closure contact.
N : PS-2410LD, PS-2410LC
48
Two-Wire Bus System
Entrance station modules & panels
System layout example
Audio Module
. AUDIO
#2
Specifications (GF-DA)
#1
1P
1P
AIPHONE
GF-DP
GF-DA
Audio panel
Audio module
Consumption
Entrance station
Wiring
Type of cable
1P
AIPHONE
H
H
M
AUDIO
M
GF-BC
N
Call switch Module
Mounting
Housing
Weight
. AUDIO & VIDEO
#2
30mA
5
Single-pair cable common
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm dia.~1.0mm
dia.
Box and front frame GF-2B,3B
and GF-2F,3F
Fire-retardant Plastic
Approx. 180g
#1
1P
GF-1P
GF-2P
1-call panel
2-call panel
1P
Specifications (GF-SW)
1P
Capacity
Lighting
Housing
Weight
1P
AIPHONE
GF-3P
GF-4P
3-call panel
4-call panel
GF-SW
AIPHONE
H
H
M
GF-VBC
GF-BC
N
N
M
#2
Camera Module
#1
1P
1P
Specifications (GF-VA)
Consumption
Entrance station
Wiring
Type of cable
. AUDIO & VIDEO + GF-NS
Call switch module
1P
1P
N
GF-VA
Camera panel
Camera module
Specifications (GF-NS)
Digital name scrolling module
Power source
Unit dimensions
. GF-DP
(1)
Consumption
Wiring
Type of cable
7.9
110
AIPHONE
GF-NS
225
GF-NSP
LCD directory panel LCD directory
135
(2)
GF-10KP
GF-10K
16
44
Housing
Weight
Specifications (GF-10K)
320
Access control keypad module
16
135
Housing
Fire-retardant Plastic
Lighting
Yellow LED
Weight
Approx. 90g
44
Specifications (GF-AD)
(3)
Lineup
Weight
Approx. 90g
E
N
O
C
L
Yellow LED
9
Z
P
W
J
G
I
3
8
T
U
Fire-retardant Plastic
Lighting
6
K
M
S
B
5
Housing
F
2
A
H
7
D
4
V
1
Q R
AIPHONE
225
Access control keypad module
X Y
0
270
GF-AP
GF-AD
GF-BP
Address panel Address module Blank panel
49
24V DC, supplied by a power
supply PS-2410LD, LC
0.07A
Two single-pair cables common.
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm ~ 1.0mm
dia.
Fire-retardant Plastic
Approx. 150g
AIPHONE
Digital keypad panel Digital keypad
GF-AC
140mA
5
Two single-pair cables common
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm ~ 1.0mm
dia.
Fire-retardant Plastic
Approx. 140g
N : PS-2410LD, PS-2410LC
95.2
MULTI-UNIT ENTRY SECURITY
Housing
Weight
GF-VP
100-call buttons
Yellow LED
Fire-retardant Plastic
Approx. 90g
16
44
(1) Audio, 4-call (2) Audio, 8-call (3) Audio/Video + Name scroll
Entrance station mounting accessories
Mounting
Front frame & back box
. GF-nHBA
. GF-nHA
GF-DP
GF-3F
W
GF-3B
GF-DA
42
(4) H
W
GF-2F
GF-3F
GF-2B
GF-3B
2-module
front frame
3-module
front frame
2-module
back box
3-module
back box
(3)
(5)
(2)
(1)
61
45
65
H
GF-SW
W
H
H
22
GF-4P
. GF-202BA
85
W
H
W
GF-102HA/HBA 243 155
GF-102BA 229 139
GF-202HA/HBA 243 290
GF-202BA 229 274
GF-103HA/HBA 338 155
GF-103BA 324 139
GF-203HA/HBA 338 290
GF-203BA 324 274
GF-303HA/HBA 338 425
(1) Tamper-proof screw & screwdriver (supplied with GF-BC) (2) Module-mounting bracket (supplied with
GF-3F) (3) Internal wiring connector (4) Joint pipe(x2) (5) Cut out openings in advance.
Back box
1.
Hooded surfacemount box
Rain hood
3.
200
mm
GF-nHBA
GF-nHA
(1)
2.
(1)
295
mm
25mm
GF-nBA
25mm 25mm
44mm
W
Surface-mount
box
(2)
44mm
(2)
W
1. Two 2-module back boxes
2. Three 3-module back boxes
(1) Joint pipe(x2) (2) Do not recess back box more than 15mm.
GF-2B/3B
x1
x2
x3
x4
x5
x6
x7
x8
x9
W
110
245
380
515
650
785
920
1055
1190
3. Back box total width (mm)
AUDIO
(1) 4.
8.
AIPHONE
AUDIO / VIDEO
AIPHONE
(1) 4.
(1)
(3)
(4)
(5)
(6)
(7)
(8)
GF-VA
GF-VP
GF-DA
GF-DP
GF-SW
GF-4P
GF-2P
GF-2F
GF-2B
GF-3F
GF-3B
GF-BP
GF-AD
GF-AP
GF-NS
GF-NSP
GF-10K
GF-10KP
16.
AIPHONE
8.
AIPHONE
(2)
12.
AIPHONE
12.
AIPHONE
20.
AIPHONE
16.
AIPHONE
30.
AIPHONE
AIPHONE
20.
AIPHONE
AIPHONE
30.
AIPHONE
GF-NS
GF-10K
40.
GF-NS
GF-10K
40.
AIPHONE
AIPHONE
AIPHONE
4.
1
1
1
1
1
1
-
4.
1
1
1
1
1
1
1
1
8.
1
1
2
2
1
1
8.
1
1
1
1
2
2
2
2
-
12.
1
1
3
3
2
-
12.
1
1
1
1
3
3
2
2
16.
1
1
4
4
2
2
16.
1
1
1
1
4
4
2
2
20.
1
1
5
5
2
2
20.
1
1
1
1
5
5
3
3
30.
1
1
8
7
1
3
3
30.
1
1
1
1
8
7
1
4
4
40.
1
1
10
10
4
4
40.
1
1
1
1
10
10
4
4
GF-NS, GF-10K
1
1
1
1
GF-NS, GF-10K
1
1
1
1
2
2
-
-
-
-
-
-
-
1
-
-
1
-
1
1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
1
1
1
1
1
1
1
MULTI-UNIT ENTRY SECURITY
Entrance station components
(1) Number of calling button (2) Camera (3) Audio (4) Call switch (5) 2-module Front frame (6) 3-module Front frame (7) Option (8) Digital name scroll
50
Two-Wire Bus System
Residential station
Residential audio station
GF-1D
Apartment station
Features
Specifications (GF-1D, GF-1DK)
Auto-Entry (Auto door strike)
Setting required.
Call tone from Entrance and
Doorbell are differentiated.
Power source
24V DC, supplied from 2-wire
Bus control unit GF-BC
Consumption
Total station
Wiring
16mA
250 residential stations
Single-pair cable common
Type of cable
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm dia.~1.0mm
Trunk line
GF-1DK
AUDIO
Concierge call apartment
station
w/Panic call transfer
(Photo)
GF-1D
GF-1D
1P
1P
1P
GF-BC
N
AUDIO &
VIDEO
AUDIO &
VIDEO
1P x 2
GF-1MDK GF-1MDK
GF-1MDK
1P x 2
1P x 2
M
Residential monitor station
Specifications (GF-1MD, GF-1MDK)
24V DC, supplied from Bus
control unit, GF-BC & GF-VBC
M
Consumption
356mA
M
Total monitor station150 GF-1MD(K)’s.
1P x 2
1P x 2
GF-1MDK
w/Service button
1P x 2
GF-1MDK
GF-1MDK
1P x 2
250 GF-1MD(K)’s w/GFW-VBC,
M
Expander video control units.
1P x 2
l BUS line (audio); Max. 50 stations
l Video line; Max.25 Monitors either via max.
6xGF-4Z’s or Monitor to Monitor. Do not mix two
wiring methods on a same trunk line.
Video monitor
4 inch direct view flat CRT
Wiring
Two Single-pair cables common
Type of cable
2-conductor cable solid copper
& non-braided, polyethylene
Unit dimensions
insulation, 0.65mm dia.~1.0mm
GF-1DK, GF-1D
GF-1MDK, GF-1MD
dia.
89
60
83.5
60
83.5
210
GF-1MD
200
MULTI-UNIT ENTRY SECURITY
DOORBELL BUTTON
(option)
Fire-retardant plastic
Approx. 370g
Power source
M
GF-1MDK
M
Apartment station
Concierge call apartment
monitor station
(w/Panic call transfer)
(Photo)
Housing
Weight
1P x 2
GF-1MD
GF-1MDK
dia.
Wall-mounting only
60mm or 83.5mm guided
M
1P
GF-4Z
GF-1MD-SW
Mounting
Electrical box
1P
DOORBELL BUTTON
(option)
216
63
Mounting
Wall-mounting only
Electrical box
60mm or 83.5mm guided
Housing
Fire-retardant plastic
Weight
Approx. 1200g
69
Concierge station
For either audio or audio/video system
Trunk line
Specifications (GF-MK)
GF-1DK
GF-1DK
1P
1P
1P
1P
O
O
Consumption
LCD display
Wiring
Type of cable
50mA
Max. 16 letters for names
Two Single-pair cables common
2-conductor cable solid copper
& non-braided, polyethylene
insulation, 0.65mm dia.~1.0mm
dia.
Wall-mounting or Desk-top
mounting on GFW-S
60mm or 83.5mm guided
Fire-retardant plastic
Approx. 900g
1P
GF-1DK
1P
O
Mounting
1P
O
1P
H I
3
B C
5
J
N O
7
K L
Z
W
U V
E F
6
8
T
Q R
X Y
M
W
N O
9
X Y
0
GF-MK
GF-MK
60
83.5
0
210
T
9
P
4
6
G
P
S
2
E F
D
K L
8
U V
1
3
B C
5
M
7
Q R
A
H I
J
51
4
G
Desk-top stand
GF-BC
2
D
1P
GF-MK
1
A
1P
Unit dimensions
1P
S
Concierge station
Z
GF-MK
GFW-S
Electrical box
Housing
Weight
GF-1DK
1P
1P
N
O Panic call switch
l Must be used with GF-1DK or GF-1MDK in
Concierge station application.
215
69
Bus & Video control units
System layout example
AUDIO
Specifications (GF-BC)
MAX.50
GF-1DK
1P
1P
Power source
MAX.50
1P
GF-1DK
GF-1DKGF-1DK
1P
1P
1P
Mounting
Weight
MAX.50
1P 1P
1P
BUS(AUDIO)
Specifications (GF-VBC)
1P
1P
1P
1
2
B
A
3
E
4
G
H
C
D
5
I
K
J
N
7S
PQ
8
R
O
1
Y
4
G
0
2
H I
P
6
8
W
T
U V
E F
N O
Power source
24V DC, supplied by a power
supply PS-2410LD, LC
1,100mA.
Single-pair cable common.
DIN rail
Approx. 260g
9
X Y
Z
S
K L
M
7
Q R
3
5
J
Bus control unit
B C
D
9Z
WX
V
A
T
U
F
6
L
M
GF-BC
1P
1P
Consumption
Wiring
Type of cable
GF-1DK
1P
GF-1DK
1P
24V DC, supplied by a power
supply PS-2410LD, LC
900mA.
Single-pair cable common.
2-conductor cables solid copper &
non-braided, polyethylene
insulation, 0.65mm ~ 1.0mm dia.
DIN rail
Approx. 450g
0
GF-MK
& GFW-S GF-MK
#4
#5
#3
GF-BC
1P
N
1P
H
#2
M
Consumption
Wiring
Mounting
Weight
Specifications (GF-4Z)
Wiring
Type of cable
#1
Two single-pair cables common.
2-conductor cable solid copper &
non-braided, polyethylene
insulation, 0.65mm ~ 1.0mm dia.
Approx. 450g
AUDIO / VIDEO + GF-NS
GF-1MDK
GF-1MDK
1P x 2
M
GF-4Z
1P x 2
Weight
M
Wiring distance
GF-VBC
Video control unit
1P x 2
1P x 2
M
1P x 2
GF-1MDK
GF-1MDK
BUS(Audio / Video) MAX.6
3
2
5
4
6
1P x 2
GF-BC
1P
GF-VBC
1P
1P
1Px2
1P
1Px2
1Px2
N
N
1P
1Px2
1P
1P
N
1P
1Px2(*)
N
(10)
GF-4Z
4-apt. Bus junction unit
AUDIO system
l Max. 250 Apartment stations l Max. 5 Entrance stations
l MAX 100-call panel l Max. 3 Entrance stations per BUS line
Audio/video system
l Max. 250 Apartment monitor stations
l Max. 5 Entrance camera stations
l Power supply for five GF-NS’s
1Px2(*) : 1P for Audio & 1P for power supply of GF-NS’s
M Optional door strike at each entrance
Unit dimensions
GF-BC, GF-VBC, GF-4Z
MULTI-UNIT ENTRY SECURITY
1
Distance (Diameter of wires)
GF-BC to Distribution point
5m (0.8mm)
Distrib. point to Entrance station 300m (0.8mm)
Distrib. point to GF-1K(farthest) 300m (0.8mm)
GF-VBC to farthest GF-1MDK 1 per resid. line
100m (0.8mm), 150m (1.0mm)
GF-VBC to farthest GF-1MDK 2 per resid. line
50m (0.65mm), 100m (0.8mm),
150m (1.0mm)
GF-VBC to Entrance station(GF-VA, Video)
100m (0.8mm), 150m (1.0mm)
GF-BC, VBC/A to ea. Power supply
5m (0.8mm)
GF-NS/A to Power supply
300m (0.8mm), 300m (1.0mm)
MAW-B to Entrance station
300m (0.8mm)
Total wiring distance(R1, R2)
2.5km (0.8mm)
108.5
M
122.5
61
Power supply
Unit dimensions
Specifications
PS-2410LD
PS-2410LC
Power supply
PS-2410LD
PS-2410LC
Power source
220-240V AC
120V AC
164
Secondary output voltage & current
RD
PS-2410LC
24V DC, 1A
66
95
PS-2410LD
24V DC, 1A
BK
RD: Red, BK: Black
52
Two-Wire Bus System
Long distance adaptor(Audio)
Wiring
Sub-Bus No.1
Sub-Bus No.2
Sub-Bus
Accumulated total wiring
Apartment
station
distance 2500m
max.100/Sub-Bus
Farthest Apartment
1P total 250/system
1P
station max.150m
GF-BC
Sub-Bus No.9
1P
GF-BC
N
GFW-LD
GFW-LD
Sub-Bus No.10
1P
GF-BC
GFW-LD
N
GFW-LD
1P
1P
GF-BC
N
1P
Long distance adaptor
for audio
1P
1P
Common Bus
Accumulated
total wiring
distance 2000m
Wiring distance
GF-DA-Apartment
station
GF-MK-Apartment
station
max. 600m
N
GFW-LD
1P
1P
1P 1P
1P
1P
1P
GF-MK
GF-MK
GF-BC
1
3
E
2
B
F
5
I
K
L
M
M
PQ
PQ
V
F
O
9Z
WX
T
U
WX
T
8
R
Y
3
6
N
7S
O
9Z
C
E
4
H
6
J
J
L
N
V
G
G
K
U
D
D
Max.5
C
5
I
8
R
A
A
N N
1
2
B
4
H
7S
Y
0
0
Max.2
*Communication method : Auto-voice actuation
Expanded video control unit
Unit dimensions
Wiring
GFW-VBC
5
+ –
Expander video control
unit
GF-VBC
GF-4Z
1P x 2
1
+
GF-1MDK
B1 B2
5
6
1
AUDIO
BUS
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
Consumption
Wiring
R1,R2
OUT6 OUT5 OUT4 OUT3 OUT2 OUT1
IN5 IN4 IN3 IN2 IN1
A1 A2 A1 A2 A1 A2 A1 A2 A1 A2
Type of cable
R1 R2
+ –
N
GF-BC
61
Specifications
Power source
VIDEO BUS
4
3
2
N
+ –
–
122.5
OUT6 OUT5 OUT4 OUT3 OUT2 OUT1
IN1
+ –
N
24V DC, supplied by a
power supply
PS-2410LD, LC
0.9A.
Two single-pair cables
common
2-conductor cable solid
copper & non-braided,
polyethylene insulation,
0.65mm dia~1.0mm dia.
Standard & Expanded video wiring (w/GFW-VBC) (1) Required when a second GF-1MD is installed in an apartment(s).
System layout example
6~11
1.
1~5
6~11
2.
1Px2 1Px2 1Px2 1Px2 1Px2 1Px2
GFW-VBC
1~5
IN
1P
150m
150m
150m
MULTI-UNIT ENTRY SECURITY
GFW-VBC
GFW-VBC, GFW-LD
MAX.6 x GF-4Z's GF-1MDK
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
N
(1)
VIDEO BUS
2
3
4
108.5
6
1P
N
1P
150m
1Px2 1Px2 1Px2 1Px2 1Px2 1P
GF-VBC
AUDIO
GF-BC
1P
VIDEO BUS
2
N
1P
AUDIO BUS
1. Increase wiring distance to the farthest monitor stations
1~5 Standard Bus lines 6~11 Expanded Bus lines
N
2
GF-BC
IN
VIDEO 2
N
1P
GF-VBC
GFW-VBC
1P
N
VIDEO 1
150m
2. Increase Video trunk lines
Option
MAW-B
Auxiliary light control relay
for entrance light
53
W-DIN11
DIN mounting rail
for GF-BC, GF-VBC,
GF-4Z, GFW-VBC
GFW-LD
N
AUDIO
AC-10S
AC-10F
Access control keypad,
surface mount
m P.95
Access control keypad,
flush mount
m P.95
Two-Wire Electric Lock Door Phone
ENTRANCE
RESIDENCE
4 DA-4DS
1
Entrance station
Lineup
Residential station
EL-12S
AC-10S
Electric door
strike
m P.97
DA-2DS
DA-4DS
2-call door station
4-call door station
Access control
keypad,
surface mount
m P.95
DAR-1
Call extension
AC-10F
Access control
keypad,
flush mount
m P.95
DA-1MD
Master station
DAW-P
Power supply
PT-1211D
PT-1211C
DA-2DG
DA-4DG
2-call door station
4-call door station
m P.99
Wiring
l Two-wire system
l Door release wired to door station, requiring no power
transformer
l User-optional function button
l Call tone MUTE with indicator
l Call extension sounder
310m / 1.0mma
155m / 1.0mma
DA-4DS
DA-4DG
M
DA-1MD
2
2
DA-1MD
2
P
P
DA-1MD
2
2
P
P
DA-1MD
2 DAR-1
2 AC15
(1)
Communication network
DA-1MD
DA-1MD
DA-1MD
DA-1MD
EL-12S
M
Electronic tone. Direct select ring.
~
~
D
E
L
L
(2)
DA-4DS,
DA-4DG
1 D
E
2 D
E
3 D
E
4 D
E
P
~
~
AC15
~
~
AC15
~
~
AC15
PT-1211D/C
D
E
P
P
D
E
D
E
P
S
SE
Unit dimensions
DA-2DS,G
DA-4DS,G
(3)
22
DA-1MD
61
175
DA-1MD
DA-1MD
DAR-1
(1)
DA-1MD
DA-4DS,
DA-4DG
2x2
200
100
SW
SW
DA-1MD
89
NP
MULTI-UNIT ENTRY SECURITY
Features
Door station
mounting plate
(83.5mm)
2x2
2x2
2x2
PT-1211D/C
(1) Ext. device Relay/Controller : User-optional function(AC18V, 40mA) (2) Door
release : EL-10S or 16V AC, 20 d or more (3) When a single common power
supply is used
Specifications (DA-4DS, G)
Power source
Power supply
Communication
Wiring
Distance
15V AC
PT-1211D, PT-1211C
Press and hold down Button to call.
2 wires, throughout system: PS - Master - Door - Door rlse.
PT-1211D/DR ~ Door rlse. 110m(0.6mma) 200m(0.8mma) 310m(1.0mma)
PT-1211D/DR ~ DA-1MD 55m(0.6mma) 100m(0.8mma) 155m(1.0mma)
54
Audio Entry Security
ENTRANCE
RESIDENCE
58 VC-M
1
Entrance station
Residential station
VC-0M
VC-4M
VC-6M
VC-10M
Blank entrance station
4-call entrance station
6-call entrance station
10-call entrance station
Power supply
PS-1225S
PS-1225UL
PS-1225
VCH-8
VCH-16
8-call add-on panel
16-call add-on panel
RY-PA
Electric door strike
m P.97
Door release relay
m P.97
Apartment station
Other Panels
VC-1M,VC-2M&VC-8M
m P.99
MULTI-UNIT ENTRY SECURITY
Features
VC-K
EL-12S
Wiring
l Single entry 0 to 10-call panel
l Add-on 8 or 16 call panel(s)
l VC-K handset, one or two per residence
l Directory back illumination
l Single or larger panels up to 58 buttons
800m / 1.0mma
VC-6M
VC-K
VC-K
7
4+1x3
VC-K
M
H
Q
5
VC-K
7
(1)
VC-K
6
VC-K
6
5
4+1x6
2
T
VC-6M
VC-K
VC-K
VC-K
1
2
3
4
1
2
3
4
1
2
3
4
B
B
B
Communication network
VC-6M
VC-K
#1
M
EL-12S
YL
BK
1
2
3
4
1
2
3
4
+
+
+
+
+
+
B
+
---
1
2
3
4
B
B
T
L+
L---
#6
H
Direct select ring
55
1
2
3
4
(1) 4 common + 6 (no. of apartments) * Terminal 4 for door release
T : PS-1225/S/UL H : AC transformer Q : RY-PA relay
BK: Black(2) YL: Yellow(2)
Entrance call panel
Lineup
VC-BBX
Surface
mount box
AC-10S
Access control
keypad,
surface mount
m P.95
VC-26MY
26-call entrance station
AC-10F
VC-26MT
VC-58MT
26-call entrance station
58-call entrance station
Access control
keypad,
flush mount
m P.95
VC-42MY
42-call entrance station
Unit dimensions
(1)
VC-K
2
VC-K
VC-K
(2)
VC-K
VC-K
VC-M
(2)
(1)
60
156
83.5
VC-K
1
210
VC-4M
230
Bz
1
2
3
4
B
1
2
3
4
+
+
1
2
3
4
1
2
3
4
1
2
3
4
YL
68
Q
BK
B
+
80
61
T
B
+
+
-
1
2
3
4
B
VC-M, VCH
VC-26MY
VC-42MY
VC-26MT
VC-58MT
VC-BBX
B
T
Added variations
(1) Two VC-K stations per apartment. Calling is not available between room
stations 1 & 2.
(2) Use a local buzzer or bell rated less than 24V DC, 2.5A.
T : PS-1225/S/UL Q : RY-PA relay
YL : Yellow(2) BK : Black(2)
H
260
260
260
487
487
–
(1)
W
186
339
492
186
339
–
D
2
2
2
2
2
–
H
230
230
230
457
457
264
(2)
W
156
309
462
309
309
190
D
68
68
68
68
68
52
MULTI-UNIT ENTRY SECURITY
Wiring
Multiple box mounting; Keep a distance of 186mm between two box centers.
(1) Front panel (2) Back box
Specifications (VC-M)
Power source
Power supply
Communication
Wiring
Distance
12V DC, 80mA (intercom).
100mA (lamp)
PS-1225S, PS-1225UL, PS-1225
Electronic buzzer rings VC-K station(s). (Freq.: 600Hz.
approx.) Take (either) handset to reply. Single open
channel.
4 common + no.(residences), in loop.
VC-M ~ VC-K: 35d looped.
VC-M ~ power supply: 4d looped.
VC-M to VC-K 330m(0.65mma) 800m(1.0mma)
VC-M to PS-1215DIN 40m(0.65mma) 90m(1.0mma)
56
Open Voice Intercom
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
DOOR
ROOM
1
1 LEM-1DL
Door station
Master station
Lineup
VC-BBX
LE-DA
LE-D
AC-10S
Sub station
m P.62
Sub station
m P.62
Access control
keypad,
surface mount
m P.95
LEM-1DL
Master station
AC-10F
Access control
keypad,
flash mount
m P.95
EL-12S
Electric door
strike
m P.97
LE-DL
Power supply
PS-1225S PS-1225UL
PS-1225 m P.99
Sub station
m P.62
Features
Wiring
l Single door open voice access control system
l Adjustable tarnsmit (front) and tone volumes
l AC/DC power supply
(1)
300m / 0.8mma
LE-D
LEM-1DL
2
Communication network
2
M
LE-D
1
E
1
E
–
LEM-1DL
EL-12S
12V AC,
180mA
(
M
EL
EL
+
–
)
H
(2)
LE-D
LEM-1DL
2
Unit dimensions
LE-D
1
E
–
LEM-1DL
M
2
1
E
EL-12S
EL
EL
120
83.5
180
PWR
29
88
143
LE-DA
53.5
Specifications (LEM-1DL)
LE-DL
83.5
175
83.5
115
Power supply
Communication
10
120
25.5
Wiring
Distance
57
H/T
(1) Using EL-12S door release
(2) Using door release of other manufacture rated : 30V AC/DC, 1A max.
Do not remove shorting link on LE-D. PWR : Power source
Power source
116
+
–
12~16V AC, 4VA
12~24V DC, 200mA (24V)
AC transformer, PS-1225S, PS-1225UL, PS-1225
When called by tone, press TALK to reply. Press door
release button to release door, and press OFF for
standby.
2 wires, non-polarized (+2 for EL-12S)
LEM-1DL to door 200m(0.65mma) 300m(0.8mma)
Open Voice Intercom
MASTER
SUB
Master station
Door station
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
3 LEM
1
Room sub station
LE-D
Sub station
m P.62
LEM-1
1-call master
LE-A
Sub station
m P.62
LEM-3
3-call master
LE-DA
Sub station
m P.62
Power supply
PS-0602D PS-0602C m P.99
LE-AN
Privacy sub
m P.62
Features
Wiring
l Open voice communication
l Push-to-talk at master, hands free at remote
l LE sub stations: either door station or room sub station
l Voice volume control
300m / 0.8mma
LEM-1
LEM-1
LE-A
2
Communication network
LEM-1
LEM-1
1
E
LE-A
1
E
–
+
–
LEM-3
LEM-3
300m / 0.8mma
LE-D
300m / 0.8mma
LE-A
LEM-3
2x2
2
LE-A
LEM-3
LE-D
W
LE-AN
2
LE-AN
1
1
E
–
2
LEM-1; Tone or voice. LEM-3; Selective call w/tone or voice. Tone and LED from
sub
1
E
–
E
Unit dimensions
3
LEM-3
+
–
★ Do not remove shorting link on subs.
180
160
LEM-1, LE-A, LE-AN
W
1
E
–
W : PS-0602D, PS-0602C
Specifications (LEM)
131
51
143
LE-D
115
83.5
29
116
Power source
Power supply
Communication
83.5
LE-DA
120
88
53.5
10
Output
Wiring
Distance
6V DC, 200mA
PS-0602D, PS-0602C
Sub calls in w/tone and LED, 20 sec.
Depress selector button and press or release TALK
button. Sub called by tone or voice.
Reply hands-free.
350mW output, adjustable
2 parallel wires per sub, non-polarized
LEM to sub 200m(0.65mma) 300m(0.8mma)
58
Open Voice Intercom
STATION
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
11 LEF
Master station
Master station
LEF-3
3-call master
LEF-3L
3-call master w/
door release button
LEF-5
LEF-10
5-call master
10-call master
LEF-5W
LEF-10W
5-call master
w/terminal box
10-call master
w/terminal box
LEF-10S
10-call master (all call)
Power supply
PS-1225S PS-1225UL PS-1225 m P.99
Features
Wiring
l Intermixable system with any number of masters and subs to
max. capacity
l Selective calling from any master with hands-free reply
l LEF surface and LEF-C semi-flush units can be intermixed
l Variety of sub stations are available
l Weather-resistant door stations (any number) with selective door
release
l System options: PanTilt door/monitor(s), All Call/Music/Chime
l Selective door release with LEF-5/10/10S (w/RY-PA)
Door answering w/selective door release
300m / 0.8mma
LE-D #2
LE-D #1
C
2
3
4
5
1
1
LEF-5
E
E
LEF-5
–
–
YL
M
Q
Q
LEF-5
EL-12S
EL-12S
Selective call between inside stations. Answering & releasing door from any
inside station
Cabling
Models
LEF-3
LEF-5
LEF-10
LEF-10S
Capacity
4 stations
6 stations
11 stations
11 stations
Cable
9 wires
11 wires (+5: K1~K5*)
17 wires (+10: K1~K10*)
20 wires (+10: K1~K10*)
l K1 ~K10: Control terminals for video, door release.
l LEF-3 does not have L terminal.
l Door & inside sub stations can ring 2 or 3 LEF masters.
l LEF All-master trunk cable=5 (or 6) common + no.of LEF (& subs)
59
LEF-5
13
3
LE-D
M
LEF-5
13
RY-PA's
Communication network
LE-D
LEF-5
4
3
1
C
3
4
5
1
2
C
4
5
1
2
3
E
R
Y
+
–
E
R
Y
+
–
E
R
Y
+
–
L
L
L
K4
K5
K4
K5
K4
K5
BK
H
C : PS-1225S, PS-1225UL, PS-1225 H : AC transformer
Terminal 4 : for LE-D1, Terminal 5 for LE-D2.
YL : Yellow(2) BK : Black(2).
T
Lineup
Room sub station
LE-D
LEF-20(S)*, 20-call master (photo)
LEF-30(S)*, 30-call master
LEF-40(S)*, 40-call master
*Not available in Europe, Australia,
LE-A3
Sub station
m P.62
3-call sub
LE-A
Sub station
m P.62
EL-12S
RY-PA
Electric door
strike
m P.97
Door release relay
m P.97
LEW-5
LEF-5 terminal
box
LEW-10
LEF-10 terminal
box
nor New Zealand
LEW-10S
LEF-10S terminal
box
All call, music & chime
LE-DA
LE-AN3
Sub station
m P.62
3-call privacy sub
LE-AN
AC-10S
BG-10C
Access control
keypad,
surface mount
m P.95
All call, chime & music
adaptor
m P.62
Privacy sub
m P.62
Access control
keypad,
flush mount
m P.95
Unit dimensions
LEF-3
Intermixed configuration
LEF-5, 10, 10S
3
BG-10C
LE-D
18
3
LEF-10S
LEF-10S LEF-10S LEF-10S
22
22
22
131
143
53.5
LE-A3, AN3
1
1
E
E
–
–
EL-12S
H
P1
P2
P3
+
–
YL BK
Q
Q
C
2
3
4
5
6
7
8
9
10
1
E
R
Y
+
–
L
1
C
3
4
5
6
7
8
9
10
2
E
R
Y
+
–
L
1
2
C
4
5
6
7
8
9
10
3
E
R
Y
+
–
L
1
2
3
C
5
6
7
8
9
10
4
E
R
Y
+
–
L
K9
K10
K9
K10
K9
K10
K9
K10
P1
P2
P3
P1
P2
P3
P1
P2
P3
P1
P2
P3
T
3 wires per sub. Run 3 wires to subs individually, or use multi-conductor cable to
wire multiple subs (2 common + 1 per sub).
l LE-D call-in chimes on LEF stations.
l Only LEF-10S station can transmit all call.
l Match door release control terminals (Kn) with door selector #10 with K10, #9
with K9.
★ Remove a shorting link on LE subs.
T : PS-1225S, PS-1225UL, PS-1225 H : AC transformer Q : RY-PA
BG-10C
165
1
2
3
4
5
6
7
8
DB
DA
11
E
R
Y
+
–
M
51
55
190
180
M
EL-12S
206
180
LE-D
LE-A, AN
160
Wiring
AC-10F
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Door station
250
143
77
53.5
Specifications (LEF)
Power source
Power supply
Communication
Door release
Selector switch
Wiring
Distance
12V DC, 300mA per LEF station.
PS-1225S, PS-1225UL, PS-1225
Sub calls in w/(chime) tone & LED, 20 sec.
Depress the LED lit selector button. Use
TALK/LISTEN switch. Master calls in w/tone or
voice (no LED lit). Reply hands-free. To call,
depress a selector, and call by voice or tone.
Contact: 30V DC, 0.1A (resistance load).
Contact: 12V DC, 30mA.
5 wires common + no .LEF (& subs) (all-master system)
2 wires per sub (single-master system).
* E to - link remains attached.
LE subs: 3 wires with the link removed (when intermixed)
Farthest LEF’s 200m(0.65mma)
300m(0.8mma)
Specifications (BG-10C)
Power source
All call transmit
All call receive
Chime tone transmit
Controls
Wiring
Distance
12V DC, 2.5A (music max. output).
1.5A(music, chime & all call). 0.1A standby
From LEF-3C, 5C, 10C & LEF-1C and LEF-10S
All LEF master station, and LE-C, CN
AUX R, E and AUX L, E
Music on/off. 11 selector switches of music &
chime, chime only or off.
19 wires max. BG-10C to LEF-10C.
3 wires to each LE-D, DA.
BG-10C to LEF-C 150m(0.65mma).
230m(0.8mma)
LE-D/DA to BG-10C 200m(0.65mma).
300m(0.8mma).
60
Open Voice Intercom
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
DOOR
ROOM
3
8 LEF-C
Door station
Master station
Sub station
LE-D
Sub station
m P.62
LEF-3C
All call sub master
Sub station
*Not available in Europe
LEF-5C
LEF-10C
5-call master
10-call master
LE-BN*
Privacy sub
*Not available in Europe
LE-C*
Sub station
w/MUSIC receive
volume control
*Not available in Europe
LE-CN*
Power supply
PS-1225S PS-1225UL PS-1225
Privacy sub
w/MUSIC receive
volume control
*Not available in Europe
m P.99
Features
Wiring
l Intermixable system with any number of masters and subs to
max. capacity
l Selective calling from any master with hands-free reply
l LEF surface and LEF-C semi-flush units can be intermixed
l Variety of sub stations are available
l Weather-resistant door stations (any number) with selective door
release
l System options: PanTilt door/monitor(s), All Call/Music/Chime
l Selective door release with LEF-5/10/10S (w/RY-PA)
LEF-10C✕7
(20)
1
2
3
4
5
6
7
LE-D
1
LEF-10C
LE-D
LEF-10C
LEF-10C
E
–
LE-B
LEF-10C
LE-B
BK
YL Q
LE-B
H
EL-12S
DA
–
9
10
11
E
R
Y
+
–
P1
P2
P3
+
–
DCIN
Power source
Power supply
Communication
LEF-1C
LE-B/BN
LE-C/CN
15.5
15
20
200
15.5
40
20
208
200
208
238
Output
153
3
3
1
C
2
3
4
5
6
7
8
9
10
1
E
R
Y
+
–
L
P1
P2
P3
1
C
2
3
4
5
6
7
8
9
10
2
E
R
Y
+
–
L
P1
P2
P3
1
2
3
C
4
5
6
7
8
9
10
3
E
R
Y
+
–
L
1
2
3
4
C
5
6
7
8
9
10
4
E
R
Y
+
–
L
1
2
3
4
C
5
6
7
8
9
10
5
E
R
Y
+
–
L
1
2
3
4
5
6
C
7
8
9
10
6
E
R
Y
+
–
L
1
2
3
4
5
6
C
7
8
9
10
7
E
R
Y
+
–
L
P1
P2
P3
P1
P2
P3
P1
P2
P3
P1
P2
P3
P1
P2
P3
3
1
1
E
E
1
E
–
–
–
T
Specifications (LEF-C)
Unit dimensions
LEF-5C
LEF-10C
LE-B/BN✕3
20
20
20
20
BK : Black(2) YL : Yellow(2)
Intermixed configuration
Internal communication by Selective call. Sub calls in with tone & LED 20 sec.
LEF-3C
20
T : PS-1225/S/UL Q : RY-PA relay H : AC transformer
LEF-10C
LEF-10C
LEF-10C
20
3 BG10C
Communication network
61
LEF-1C
LE-B*
3-call master
153
Door release
15.5
15
20
Selector switch
Wiring
Distance
12V DC, 300mA per station.
PS-1225S, PS-1225UL, PS-1225
Sub/door calls in w/tone & LED, 20 sec.
Depress the LED lit selector button. Depress
TALK/LISTEN switch. The LED stays lit while in
use. Single talk channel w/OCCUPIED lit.
800mW at 20d (receive).
500mW at 20d (transmit).
Contact: 110V AC, 1A.
24V DC, 1A. (on RY-PA output).
Contact: 12V DC, 1A. (K terminals)
5 or 6 common + no. all stations
Farthest LEF-C’s 200m(0.65mma)
300m(0.8mma)
LE Sub stations & Accessories
Unit dimensions
Sub station
LE-DA
88
Sub station
29
116
83.5
175
115
120
LE-D
LE-DL
83.5
LE-DA
83.5
LE-D
10
25.5
120
LE-DL
Sub station
LE-DA; 2-gang mounting
Room sub
Semiflush mount sub
*Not available in Europe
Unit dimensions
160
LE-A, AN
131
LE-A
LE-AN
Sub station
Privacy sub
LE-B
LE-BN
Sub station
Privacy sub
LE-C
LE-CN
Sub station
Privacy sub
51
LE-C & LE-CN: w/MUSIC receive volume control
3-call sub
All call sub master
Unit dimensions
Unit dimensions
LEF-1C
LE-B/BN
LE-C/CN
180
208
LE-A3, AN3
153
143
LE-AN3
3-call sub
3-call privacy sub
15.5
15
20
53.5
LE-A3
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Weather-resistant sub
LEF-1C
All call sub master
All call/music/chime adaptor
Specifications (BG-10C)
Unit dimensions
Power source
165
BG-10C
250
BG-10C
All call, chime & music
adaptor
77
All call transmit
All call receive
Chime tone transmit
Controls
Wiring
Distance
12V DC, 2.5A (music max. output).
1.5A(music, chime & all call). 0.1A standby
From LEF-3C, 5C, 10C & LEF-1C and LEF-10S
All LEF master station, and LE-C, CN
AUX R, E and AUX L, E
Music on/off. 11 selector switches of music &
chime, chime only or off.
19 wires max. BG-10C to LEF-10C.
3 wires to each LE-D, DA.
BG-10C to LEF-C 150m(0.65mma).
230m(0.8mma)
LE-D/DA to BG-10C 200m(0.65mma).
300m(0.8mma).
62
Handset Intercom
MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
3 AT-406
1
Master station
Sub station
Lineup
TAR-3
Boxed set
External signaling
relay
m P.98
AT-406
Boxed set (white color)
AT-406P
Display pack
AT-406B/A
Boxed set (charcoal gray)
AT-306
Sub station
Master station
Power supply
PS-0602D PS-0602C or Batteries
m P.99
Features
Wiring
l Handset master-sub intercom w/2 additional subs (optional)
l Battery status LED
l Batteries or DC power supply
l Buzzer or bell activation (optional)
AT-306
AT-206
2
AT-306
2
AT-306
2
Communication network
1
2
AT-206
W
AT-306 x 3
1
2
NP
NP
1
2
NP
1
2
+
---
W : PS-0602D, PS-0602C
Specifications (AT-406)
Master calls all the subs simultaneously, while the sub rings the master only.
Power source
Power supply
Unit dimensions
Communication
AT-206
AT-306
210
83.5
Wiring
Distance
80
63
51
6V DC, 150mA
PS-0602D, PS-0602C or Batteries gAAh (SUM-3)
x 4 pcs
Press CALL button to ring all subs. Pick up any
phone. Sub rings master only. Common talk.
2 parallel wires. non-polarized
2-station set 700m(0.65mma)
1000m(0.8mma)
AT-206 to subs 1~3 400m(0.65mma)
600m(0.8mma)
Handset Intercom
STATION
Phone extension
Lineup
YAW-RB
1-zone paging
adaptor
for YAZ-90-3W
Power supply
PS-2420S
PS-2420UL
YAZ-90-3W
Phone master station
m P.100
Features
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
90 YAZ-90-3W
Wiring
l Microprocessor built-in intercom expandable to max. 90 stations
on 4-pair cable
l Up to 2.9km wiring distance
l Zone paging
l Communication functions: Camp-on busy, secretary transfer, call
transfer
l Line-off trouble on one channnel does not affect the other
channels
Communication network
YAZ-90-3W
Paging Speaker
YAZ-90-3W
2900m / 0.8mma
#10
4P
YAZ-90-3W
#39
#40
3P
4P
YAZ-90-3W YAZ-90-3W
YAW-RB
1
2
1
2
1
2
1
2
3
4
3
4
3
4
3
4
5
6
+
–
5
6
+
–
5
6
+
–
5
6
+
–
N
N
M
G
A
Paging amp.
IN
OUT
Paging speaker line
shielded
White
Power relay
AC
TB
P
G
White
Paging
speakers
Power supply
(for relay)
l Remove +,- wires between YAZ stations of different blocks.
Within a block locate a power supply in the center of cable run, and make groups
of max. 10 YAZ stations. As shown, connect +, - wires from the power supply to
each group's initial YAZ station.
N : PS-2420S, PS-2420UL, PS-2420
YAZ-90-3W
YAZ-90-3W
Specifications (YAZ-90-3W)
Power source
Power supply
Communication
Station to station communication in any pair
Unit dimensions
Line loop resistance
Wiring
Total wiring distance
YAW-RB
YAZ-90-3W
24V DC, 150mA max. 20mA standby.
PS-2420S, PS-2420UL, PS-2420 per 30-station block.
Dial 2-digit station # to ring other station with tone or voice pressing
PAGE. Privacy communication on each channel (max. 3).
Must not exceed 200d for farthest stations. 20d for power line.
4-twisted pairs (shielded) in loop.
Farthest YAZ’s 1900m(0.65mma), 2900m(0.8mma)
158
83.5
230
Specifications (YAW-RB)
152
Power source
Consumption
Paging impedance/level
59
Music impedance/level
94
84
Line resistance
Amp. power ctrl. contact
YAW-RB: 24V DC, 150mA (paging).40mA (standby).
YAW-RB = 5 YAZ’s, powered by YAZ network.
Input: 600d/78mV(RMS), 1KHz.
Output: 600d/300mV(RMS), 1KHz.
Input: 20Kd/300mV(RMS), 1KHz.
Output: 600d/150mV(RMS), 1KHz.
20d loop for power supply line.
200d loop for intercom line.
YAW-RB: 240V AC 10A. 24V DC, 10A.
64
Handset Intercom
STATION
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
25 TD-H/B
Door station
Sub station
Master station
TD-1H/B
TD-3H/B
TD-6H/B
1-call sub
3-call master
6-call master
IF-DA
Door station
m P.30
DE-UR
Door station adaptor
Power supply
PS-1225S PS-1225UL PS-1225
m P.99
Wiring
Features
l All-master selective ring system
l Single-master configuration or intermix w/TD-1H/B
l Multi-conductor cable in loop
l Multi-talk channels
l Door station(s), audio or PanTilt video (max. 2)
l Zone paging, with or without talkback
l Music source connection. Page pretone cuts out music.
(2) Door station communication
230m /
0.8mma
1000m / 0.8mma
IF-DA
DE-UR
1
1
2
1
2
2
TD-6H/B
#1
10
#2
C
2
3
4
5
6
1
C
3
4
5
6
1
2
C
4
5
6
1
2
3
C
5
6
1
2
3
4
5
6
1
2
3
4
C
#3
10
#4
10
#5
10
Communication network
TD-12H/B
TD-12H/B
TD-12H/B
Paging
Speaker
TD-12H/B
1
2
1
2
TD-12H/B
TD-12H/B
IF-DA
All-master configuration. Station selector & CALL to ring any other station.
Wiring
(1) All-master configuration
C
D
D
D
D
D
D
D
+
–
+
–
+
–
+
–
+
–
+
–
+
–
A
B
T
1000m / 0.8mma
TD-12H/B
TD-12H/B
C
#1
#2
16
#3
16
#11
#12
16
16
15m / 0.8mma
#13
16
(3) Single-master configuration
TD-3H/B
C
2
3
4
5
6
7
8
9
10
11
12
1
D
+
–
1
C
3
4
5
6
7
8
9
10
11
12
2
D
+
–
1
2
C
4
5
6
7
8
9
10
11
12
3
D
+
–
T
1
2
3
4
5
6
7
8
9
10
C
12
11
D
+
–
1
2
3
4
5
6
7
8
9
10
11
C
12
D
+
–
1
2
3
4
5
6
7
8
9
10
11
12
C
D
+
–
l Install main cable of max. condctors allowed for each TD-H/B station model.
C : PS-1225S, PS-1225UL, PS-1225 Terminal D : Door station
65
TD-1H/B
6
C
1
2
3
TD-1H/B
5
1
C
TD-1H/B
4
1
1
C
C
D
T
+
–
+
–
+
–
+
–
Terminal 5 for door 1, 6 for door 2. DE-UR’s should be powered by power
supply.
Lineup
PD-1
Zone page
adaptor
For desk-top or surface wall
mounting, provide TDW-n/A
terminal box w/1.5m cord.
TD-6Z/A
6-call master station
TD-12Z/A
12-call master station
TDW-1/A
TD-1H/B terminal box
TDW-3/A
TD-3H/B terminal box
TDW-6/A
TD-6H/B terminal box
TDW-12/A
TD-12H/B terminal box
TD-12H/B
TD-24H/B
12-call master
24-call master
TDW-24/A
TD-24H/B terminal box
full trunk all-master
configuration
l No break-in call
l Zone page(s)
in lieu of station(s)
Power supply
PS-1225S PS-1225UL
PS-1225
RY-AC/A
External signaling
relay
m P.97
Specifications (TD-H/B)
Power source
Power supply
Communication
(4) Straight paging w/PD-1 (single-zone)
PD-1
(1)
TD-12H/B
3
(1)
T
Wiring
A
G
M
No.
C
DC12V
+
---
+
---
TD-H/B
+
---
Distance
T
(2)
Power source
Power supply
Communication
Wiring
Distance
PD-2
TD-12H/B
(1)
3
T
(1)
S
S
V
V
A
G
M
Power source
No.
DC12V
+
---
+
---
+
---
TD-H/B
T
T : PS-1225S, PS-1225UL, PS-1225
(1) Paging Speakers (2) Talkback speakers
Unit dimensions
PD-1
PD-2
TD-24H/B
210
83.5
83.5
138
210
TD-1H/B ~ TD-12H/B
TD-6Z/A, TD-12Z/A
91
73
100
12V DC, 90mA per channel
PS-1225S, PS-1225UL, PS-1225
Depress a selector and CALL to ring opponent.
3 + no. TD-Z/A in loop.
TD-Z/A stations 650m(0.65mma) 1000m(0.8mma)
(PD-1,PD-2)
(2)
C
12V DC, 70mA per station.
PS-1225S, PS-1225UL, PS-1225
Depress a station selector 1~12 and CALL (or CALL A)
to ring station 1~12 (or A1 ~ A12). Lift handset to reply.
Door calls in w/standard or faster(B) intermittent tone,
2-1/2 sec. Pick up and depress the selector assigned.
2 or 3 + no. TD-H/B in loop.
TD-1H/B: 4 wires. TD-3H/B: 7 wires.
TD-6H/B: 10 wires. TD-12H/B: 16 wires.
TD-24H/B: 28 wires.
TD-H/B stations 650m(0.65mma) 1000m(0.8mma)
DE-UR to door 150m(0.65mma) 230m(0.8mma)
(TD-Z/A)
(5) Paging with talkback w/PD-2 (single zone)
100
Zone page/talkback
adaptor
l 7 or 13 identical station,
m P.99
Wiring
PD-2
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Privacy type
Output
Paging & music
tone controls
Amp. input
Music input
Tuner output
Tape output
Talkback gain
Environmental noise
Paging
Wiring
PD-1: 12V DC, 300mA.
PD-2: 12V DC, 48mA (talkback).
5Kd. Max. 1.5V
Treble 12dB at 10KHz. Bass 12dB at 100Hz.
AUX or PHONO 100K-500Kd, 0.12~0.5V
17Kd, 0.3V, 1KHz. for full output
Audio output: Range 100mV~1.2V, 10Kd or less
Low level output: Range 100mV~1.2V, 600d
40dB, 1KHz. at max. volume
Less than 80dB (phon)
Select an assigned selector # and page w/PAGE
button depressed. Release to receive reply
3 wires to TD-H/B via power supply
51.5
83
66
Integratable Audio & Video Security
MASTER
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
8
DOOR
120 AX
Central exchange unit
Master station
AX-084C
Central exchange unit,
4 masters and 8 doors
AX-8MV
AX-8M
8-call color monitor master station
8-call audio master station
AX-248C (Photo)
Central exchange unit,
8 masters and 24 doors
AX-320C
Add-on exchange unit,
32 doors
AX-16SW
Power supply
PS-2420S PS-2420UL
PS-2420 m P.100
AX-8MV, AX-16SW
16-call add-on selector
Features
l Up to 120 video entrance stations and 8 master stations
l All wired on CAT5e, homerun cabling
l Total hands-free, auto-voice actuation, communication or Press-to-talk
operataion
l Two talk channels and two video channels.
l Communication privacy
l Masters available with 3.5 inch color TFT LCD
l Selective door release
l Master-to-master selective calling and All Call
l Standard or Priority call levels from door stations
l Scan monitoring: Hands-free audio/visual monitoring
l Video output from CEU and AX-8MV
l Integrate with CCTV, Access control etc.
l PC interface for programming and event logging
l Rack or wall mountable CEU
l Compatible with IE Series door stations
l Optional features: headset, footswitch, and PC remote control
Communication network
AX-DV
AX-8MV
AX-8MV
AX-DVF
Video
signal
PC programming
AX-DM
Monitor
Calling & communication (w/video from door)
Door release
67
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Door station
Lineup
EL-12S
Electric door strike
m P.97
AX-DV
Color video
door station
surface mount
AX-DM
AX-DVF
Color video door station
flush mount
Audio door station
Mullion type
AC-10S
Access control
keypad,
surface mount
m P.95
IF-DA
Audio door station
AX-DV-P
Color video
door station
w/space for embed
proximity reader
surface mount
AX-DVF-P
AC-10F
Color video door station
w/space for embed
proximity reader
flush mount
System Integration
Access control
keypad,
flush mount
m P.95
IE-JA
Audio door station
Cabling
300m
300m
Video signal
CAT5e
AX-8MV
AX-DV
Security Integration Software
Switch
camera
System log
PC
AX
System
AX-084C
CCTV
System
Remote
door release
Video
signal
AX-8MV
AX-DVF-P
CAT5e
CAT5e
Calling &
Communication
with video
Door
release
CAT5e
AX-DVF
PS24
PS24
Door
release
history
CAT5e
Remote door release
AX-DM
Monitor
Card ID
RS232C
Door
release
Access
Control
System
Access
Control
System
PC
Camera
CCTV
Switcher
Monitor
VCR
68
Integrated Security & Communication System
Wiring
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
300m
300m
AX-8MV
Cat5e
AX-DV
Cat5e
M
2
AX-248C
AX-DVF
AX-8MV
Cat5e
Cat5e
M
2
2
2
N
N
AX-8M
Cat5e
AX-DM
Cat5e
M
2
Master #1
AX-8MV
Door #1
AX-DV
Cat5e
RJ-45
Brown
Red
Yellow
Orange
Green
Blue
Cat5e
RJ-45
Door #2
AX-DVF
EL-12S
Cat5e
H
AX-248C
PC
Master #2
AX-8MV
RJ-45
RJ-45
H
EL-12S
Door #24
Red
AX-DM
Brown
3(White green)
6(Green)
7(White brown)
8(Brown)
1
2
4
5
N
N
Cat5e
Cat5e
Master #8
AX-8M
Cat5e
EL-12S
RJ-45
H
N : PS-2420S, PS-2420UL, PS-2420 H : AC transformer
Mounting locations
69
Master station
Video door station
Install the video master station in a place where the screen
is not exposed to direct sunlight.
Do not install a video door station in any of the following locations where lighting or
the ambient environment could impact the display on the video master station due to
the characteristics of the door station's camera.
1. Locations subject to direct sunlight
2. Under street lights or door lights
3. Other locations subject to strong lighting conditions
Video +
Video IER-2
Foot switch
Components
AX-8MV
(AX-8M audio only)
AX-16SW
Number of master
stations
Number of add-on
selectors per master
1~8
up to 4
9 ~ 24
AX-DVF
AX-DM
Number of door stations
AX-084C or AX-248C
AX-320C
Number of central exchange unit
Number of add-on
exchange units
AX-084C
AX-248C
-
1
-
-
up to 8
1
-
1
-
25 ~ 40
up to 4
2
1
-
1
41 ~ 56
up to 8
3
-
1
1
57 ~ 72
up to 4
4
1
-
2
73 ~ 88
up to 8
5
-
1
2
89 ~ 104
up to 4
6
1
-
3
105 ~ 120
up to 8
7
-
1
3
NOTE: Use the AX-248C for systems with more than 4 master stations (may effect the required quantity of AX-320C).
2 pcs of power supplies are required for video system.
Image view area
Unit dimension
AX-8MV
• AX-DV, AX-DVF
AX-DV-P, AX-DVF-P
AX-8M
★
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
AX-DV
185cm
★
175
175
65cm
50cm
★
120cm
150cm
95cm
★
50cm
194
63
AX-16SW
★
63
194
approximate
AX-320C
AX-084C, AX-248C
Specifications
Power source
Power supply
Current consumption
88
85
420
426
88
85
175
420
426
Calling
63
AX-DV-P
100
Communication
AX-DVF
245
195
AX-DV
246
86
Video monitor
Scaning lines
Night viewing
25
146
100
AX-DVF-P
2 45
Door release contact
Outside video output
25
IF-DA
130
AX-DM
295
160
1-gang
98
Wiring
Wiring distance
28
IE-JA
146
22.5
115
43
2-gang
2 45
116
24V DC, 2A (Two Power supplies required per video system)
PS-2420S, PS-2420UL, PS-2420
AX-084C: Video (Max.) 650mA, Audio (Max.) 700mA
AX-248C: Video (Max.) 1150mA, Audio (Max.) 1250mA
AX-320C: Video (Max.) 280mA, Audio (Max.) 180mA
Normal call: an intermittent tremolo
Priority call: a rapid intermittent tremolo
Approx. 10-600 sec. or infinite
AUTOMATIC (Hands-free); To activate, momentarily
press TALK button.
MANUAL (Press-to-talk/Release-to-listen); To activate,
press TALK button for 1 sec. or more.
Approx. 30-600 sec.
3.5 inch direct view TFT color LCD
525 lines
Up to 30cm from camera, with white LED projected,
background beyond 30cm cannot be seen.
24V AC/DC, 0.5A
AX-084C, 248C: NTSC standard 1Vpp (0.7-1.4Vpp)
BNC x 2
Switching signal: Open collector output
24V DC, 30mA
RJ-45 x 2
AX-8MV: NTSC standard 1Vpp (0.7-1.4Vpp)
Homerun CAT5e wire to CEU
CEU to door: 300 m (CAT5e)
CEU to master: 300 m (CAT5e)
10
70
Commercial Security Intercom
MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
64 1,024 AI-900
Master station
Sub station
AI-RS150
AI-RS170
Substation, indoor
m P.73
Substation, outdoor
m P.73
AI-RS160
AI-RS180
Substation, indoor
m P.73
Substation, outdoor
emergency
m P.73
AI-MS900
Master station
m P.73
Features
l Flexible All-modular construction. Expansion options using
interface and function cards.
l Sub-to-master communication by voice switch or PTT-activated
talk-back. Master-to-master by full-duplex handsets.
l Four different substations for specific installation conditions.
l Provides a speaker and call button.
l Basic conversation plus full range of exchange functions,
including; Call forwarding, Scan monitoring, Emergency
conference, Conversation recording by way of external equipment,
and Paging by way of an external amplifier.
l Emergency calls from any substation at a central security control
room.
l Efficient voice recording at ea. master station.
l Used in combination with CCTV, access control, emergency
broadcast systems or other security equipment.
Communication network
(1)
AI-MS900
(2)
(3)
(6)
(4)
(5)
J Calling & Communication
(1) Speaker (2) Substations (3) Cordless Phone (4) Access Control (5) CCTV
(6) Personal computer. PC Link with programming and monitoring software.
71
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Mounting accessories
AI-YC303
AI-900MF wall-mounting
bracket
m P.74
AI-PU200
AI-900MF
Power transformer unit
m P.74
Main frame
m P.74
AI-PN100B
AI-PU200 rack-mount
panel
m P.74
Cabling
Wiring
AI-900MF
1. AI-MS900
(1)
AI-900RS
AI-900MS
CN1
CN1
CN2
CN2 CN3
AI-MS900
C/O
(2)
(3)
1-(1)
CN4
AI-900MF
AI-900MF
(4)
CN3
1-(1)
2. AI-900AL
Tel
AI-RS150~180
AI-MS900
2-(1)
2-(2)
2C
(5)
3. COM1
3-(1)
3-(3)
Modem
Program
PC
RS-232C
RS-232C
4-(1)
5. AI-900AF
l To double the size of the system;
Two Tie-line I/F cards are required (after that, add one I/F card
for each add’l main frame).
(1) Outside line (2) PC (for programming and system
maintenance) (3) External paging equipment (4) Substation
paging amplifier (5) shielded
AMP(1)
AMP(2)
COM1
INPUT
1P
OUTPUT
7-(1)
8. AI-900TI
2P
2P
2P
2P
2. AI-900MF
DC24V
IN
RS-232C
AI-900AF
CN4 AC-IN
CN5
CN8
AMP (16)
7. EXT. AMP.
9. AI-PU200
COM2
4-(2)
1P
1P
1P
15. LIN.
16. LIN.
2C
3-(4)
Operation
log PC
2. LIN.
CN6
RS-232C
4. COM2 3-(2)
Modem
l Basic system consists of; 4 Master stations, 64 Substations
and AI-900MF Main Frame with Interface Cards; Master(1),
Telephone(1), Substation(4), Outside line(1), Audio
function(1), and power unit(2).
1P
1P
1. LIN.
CN5
AI-900AL
CN1
AI-900TI
CN2
CN1
CN3
CN2
CN4
CN3
CN4
1P
1P
Tel
2P
CN4
AI-RS150
~ AI-RS180
6. AI-900RS
AC-IN
24V DC
AI-PU200
4
4
~ (N, L)
AI-PU200
~ (N, L)
1. Master station Interface card 1-(1)To External Record device.
2. Telephone Interface Card 2-(1),(2)To External Recording device 1, 2.
3. Programming PC Connection COM1 3-(1) Via Modem. 3-(2) RS-232C cross cable. 3-(3) Direct
connection. 3-(4) RS-232C straight cable.
4. Operation Log PC Connection COM-2 4-(1) RS-232C cross cable. 4-(2) RS-232C straight cable.
5. Audio Function Card (for paging) AMP(1)-(16): Amplifier.
6. Substation Interface Card 1.LIN.-16.LIN.: LINE1-16.
7. External amplifier 7-(1) Paging amplifier.
.
8. Tie-Line Interface Card Exchange Interconnection 8-(1) 2C shielded (data line).
9. AI-PU200 Power Transformer.
72
Commercial Security Intercom
AI-900 Components
AI-MS900
The AI-MS900 can initiate or receive calls from
programmed substations. Equipped with Pushto-Talk button for simplex communication, vox
operated handset, redial and transfer keys, and
eight auto-dial keys. Alphanumeric display for
caller ID. Two-twisted pair wiring to Main
Frame.
Unit dimensions
74.5
216
213
Features
Master station
Standard indoor substation
Features
Unit dimensions
The AI-RS150 is built with a black resin call
button and 14-gauge stainless steel. It can call
and converse with the programmed master
stations. All substation models are wired with a
shielded pair to the Main Frame.
120
2
AI-RS150
Substation, indoor
120
48.5
Indoor vandal resistant substation
Features
Unit dimensions
The AI-RS160 is made with heavy 11-gauge
stainless steel and a vandal resistant stainless
steel call button. Calls and communicates with
programmed master stations or telephones.
3
120
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Master station
AI-RS160
Substation, indoor
120
57.5
Outdoor vandal resistant substation
Features
AI-RS170
Unit dimensions
The AI-RS170 is equipped like the AI-RS160,
but with the internal components protected
with a synthetic rubber sealant, making it
weather resistant. Calls and communication
with programmed master stations or
telephones.
120
3
Substation, outdoor
120
57.5
Outdoor emergency substation
Features
Unit dimensions
The AI-RS180 is vandal and weather resistant
with a red aluminum call button, call assurance
LED, and an output to control an external relay.
Used for ADA compliance or emergency call
applications.
120
3
AI-RS180
Substation, outdoor
emergency
73
120
58.5
Features
Unit dimensions
The AI-900MF Main Frame can accommodate
the following features with the installation of
the corresponding circuit cards. Up to 4 master
stations or single line phones (2 masters per
AI-900MS card; 2 phones per AI-900AL card);
up to 64 substations; up to 2 CO lines; paging
to 19 zones; tie line connection to additional
Main Frame, RS-232 input/output for system
programming and event logging.
AI-900MF
Main frame
AI-900MF
443.7
The AI-PU200 has two 20V, 2.5A AC outputs.
One unit is required for every two AI-900RS
cards installed in the Main Frame.
420
483.6
The AI-PN100B is used to rack mount two
AI-PU200 power transformers side-by-side.
AI-PU200
AI-PU200
The AI-YC303 is used to wall mount the
AI-900MF Main Frame.
160
178
Power transformer unit
288.3
AI-PN100B
AI-PU200 rack-mount
panel
120
240V
250V 71A
OUTPUT
TO EX-200
TO FC-210
20V
2.5A 20V
2.5A
68
220V
AI-YC303
AI-900MF wall-mounting
bracket
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Main frame
Interface cards
AI-900MS Master Station Interface Card
One or two cards per Main Frame. The AI-900MS card provides
connection and audio recording outputs for one or two master stations.
With two cards installed, four master stations can be connected to one
Main Frame.
AI-900DI Direct-Select/Master Station Interface Board
Used to create a direct-select style master station in place of a digital
master. Used with AI-910DI for individual selector buttons and call-in
LEDs. Also allows integration with external security systems via
AI-910DI board.
AI-900AL Telephone Master Station Card
One or two cards per Main Frame, used in lieu of AI-900MS card. The AI900AL allows a standard telephone with caller-ID capabilities to be used
in place of a master station for communication functions. One or two
phones per card, taking the place of an AI-900MS card supporting two
master stations. Equipped with audio recording outputs for each
telephone connected.
AI-910DI Direct-Select Input/Output Relay Board
The AI-910DI is used in conjunction with the AI-900DI board to provide
relay outputs to control external devices or systems. Each board contains
32 programmable relays, and multiple boards can be used for up to 1024
relays. Use for integration with access control and/or video surveillance
systems.
AI-900RS, Substation Interface Card
Up to four cards per Main Frame. Each AI-900RS card supports up to 16
substations, and up to 64 substations per Main Frame with four cards
installed. Connect subs with simple two conductor shielded wire
homerun to the Main Frame.
AI-900CO C/O Telephone Line Interface Card
One card per Main Frame. The AI-900CO allows the connection of up to
two outside phone lines, with audio recording outputs for each line.
Integration with outside lines allows communication between sub or
master stations and standard telephones, cell phones, or pagers.
AI-900AF Audio Function Card
Connection of external PA amplifier for paging. Up to four inputs from
audio sources and 16 outputs to external paging zones. Multiple zones or
all zones can be selected and paged simultaneously.
AI-900TI Tie Line Interface Card
One card per Main Frame in multi-exchange system. The AI-900TI card is
used to interconnect multiple Main Frames, expanding the capacity and
functionality of the system. Up to four voice paths between Main Frames.
Specifications (AI-900)
Power Source
Current consumption
Communication Modes
Serial Ports
Operating Temperature
System Capacity
Master Station Mounting
Master Station Wiring
Substation Mounting
Substation Wiring
Wiring Distance:
- Master to AI-900MS
- Subs to AI-900RS
- Between Main Frames
20V AC, 2.5A, provided by AI-PU200; 24V DC
provided by external 5A power supply not
supplied Aiphone
7A
Duplex, half-duplex, and Push-to-Talk
RS-232 compliant, D-sub connector ( 9-pin
female) 2 ports
-Indoor Units
0kC~40kC
-Outdoor Units -10kC~55kC
4 master stations; 64 substations per Main
Frame
Wall or desk mount
2 twisted pairs, homerun to Main Frame
Flush mount in 2-gang box
2 conductor shielded, homerun to Main Frame
900m(0.5mma). 1500m(0.65mma)
500m(0.5mma). 800m(0.65mma)
600m(0.5mma). 1000m(0.65mma)
74
Security Window Intercom System
SERVICE SIDE
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
1
PUBLIC SIDE
1 IMU-100
Service Side
IMU-100
Main kit
IMU-100
IME-100
Operation unit
IME-100
Gooseneck microphone
Main unit
Power supply PS-2420S
PS-2420UL
PS-2420 m P.100
Features
l First in industry! Using an acoustic tube with noise cancelling
microphone
l Voice-actuated hands-free communication
l Flexible gooseneck type microphone
l Optional Mono type headset (a3.5 plug)
l Detection sensor switches automatically to communication mode
l Separate speaker system using an optional microphone
l Paging feature for announcements
l Thin shape of the acoustic tube does not obstruct the field of vision
l Holes in the barrier glass are not necessary to install
Communication network
Acoustic tube system
3
Paging
speaker
ISE-100
2
Barrier
glass
IAI-100
+
IAX-100
1
IMU-100
+
IME-100
Service Side
1
2
3
Public Side
Voice-actuated hands-free communication
Automatically switch to communication mode
Paging
Separate speaker system
3
Paging
speaker
ISE-100
2
External
speaker
+
Barrier
glass
IME-150
3
IMU-100
+
IME-100
Service Side
75
Public Side
Acoustic tube system
Separate speaker system
IAI-100
Acoustic interface kit
ISE-100
External Speaker
(locally available)
IAI-100
IAX-100
Driver unit
Sensor
+
Paging speaker
(locally available)
IAX-100
Acoustic tube
Acoustic
I/O tube
IME-150
Optional microphone
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Lineup
Public Side
Unit dimensions
Wiring
20m / (1.2mma)
IMU-100
Supplied
cable
+
Cord (3.5m)
IME-100
IME-150
160
27
ISE-100
Paging
speaker
130
40
210
49
Cord (3.5m)
Shielded
cable
2
370
External
speaker
+
24
388
2
Shielded
cable
2
2
206
Mic.
2
Acoustic I/O tube
Operation unit
45
Speaker
Main unit
Separate speaker system
IME-100
63
420
14.5
510
2
34
3800
40
IAX-100
24
N
1000
IME-150
W1
E
–
+
WHITE(C)
BLACK(H)
3500
Shielded
WHITE
RED
Shielded
WHITE
RED
–
SW
+
PG
OUT
C
H
DC24V
+
–
84
150
68
Shielded(E)
WHITE(-)
RED(+)
Connection cord
(approx. 3.5m)
ST-BY
SW
36
72
30
C
H
105
W2
115
Connector
Driver unit
23
60
Separate speaker system
ISE-100
3500
13
Supplied cable
(approx. 2m)
27
Connection cord (approx. 3.5m)
Specifications (IMU-100)
Power source
Power supply
Consumption
Operating temperature
Communication
W3
Headset
N
External speaker
Paging speaker
N : PS-2420S, PS-2420UL, PS-2420
24V DC
PS-2420S, PS-2420UL, PS-2420
120 mA (standby) 780 mA (maximum)
0kC to 40kC
Voice-actuated communication
Transmit output: 3 W 4 Ω, Receive output: 1.5 W 16 Ω
a3.5 plug, Impedance: 32 Ω, Rated input:
40 mW or more, Maximum input: 100 mW or more
Impedance: 4 to 8 Ω, Rated input: 3 W or more
Maximum input: 6 W or more
Impedance: 4 to 8 Ω, Rated input: 3 W or more
Maximum input: 6 W or more
76
Master / Sub Intercom
MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
120 NEM
1
Master station
Sub station
NB-L
Ceiling sub station
NEM-10/C
NEM-20/C
NEM-30/C
NEM-40/C
10-call master
20-call master
30-call master
40-call master
NA-NE
Sub station
NEM-10A/C NEM-20A/C
10-call master
NEM-30A/C NEM-40A/C
20-call master
40-call master
30-call master
NA-A
NA-AN
Sub station
Privacy sub station
Power supply
PS-2420S PS-2420UL PS-2420 m P.100
Features
Wiring
l Lamp memory intercom: Sub’s call-in with tone & light
l Press-to-talk or handset with voice actuation
l Selective or group call of 10 subs
l All Call
l Pre-tone sounding at sub, when selected
l Optional accessories for health care applications
l Expand beyond 40 stations with add-on selectors
NEM-40A/C
1
2
3
4
10
EE
Communication network
NA-A
NEM-40A/C
NA-A
NA-NE
NA-A
NA-A
NA-A
2
2
NA-NE
2
40
E
IER-2
NEM-40A/C
2xn
2.
NA-A
2
NA-A
2
NA-NE
2
NEM-40A/C
2 x n1
3.
NA-A
NA-A
2
2
NA-AN
NA-AN
NA-AN
77
2 x n2
2
2
NA-A
NA-A
OG/WH
BL
GR
BK
NA-NE
2
1
E
S
S
PS24
+
-
Homerun
1
2
3
4
NE-JA
N : PS-2420S, PS-2420UL, PS-2420
NEM-60A
RD
OG
31
32
33
34
Wiring
NA-A
A
B
C
D
E
NA-NE
1. Selective individual call 2. Selective group call (max. 10) 3. All call
1.
A
B
C
D
E
NA-NE
1.
2.
3.
2xn
A
B
C
D
E
2
NA-NE
1. Run a parallel cable to each NA sub station (in the same conduit).
2. Run a multi-conductor cable(s) throughout system.
3. Run multi-conductor cables up to junction box, then run a parallel cable to
each NA sub station.
A
B
C
D
E
A
B
C
D
E
NA-AN
NA-AN
RD
OG
OG/WH
BL
GR
BK
NA-NE
RD: Red OG: Orange OG/WH: Orange/White BL: Blue GR: Green BK: Black
IMPORTANT: For NE-JA sub(‘s), homerun wires to secure stable calling and
distance of 270m w/1.0mma.
NAR-6A
NB-U
Call button
Music adaptor
m P.94
NE-JA
Flush sub station
NBR-7AS
Bathroom pullcord,
moisture-resistant
NA-T/A(*1)
Handset sub station
NEM-50
NEM-50A
50-call master
50-call master
NEM-60
NEM-60A
60-call master
60-call master
NEM-70
NEM-70A
70-call master
70-call master
NBJ-20(*2)
NBJ-20B(*2)
NEM-80
NEM-80A
80-call master
80-call master
NEM-90
NEM-90A
90-call master
90-call master
NEM-100
NEM-100A
Call switching
device
for NEM-10/C,
20/C
m P.94
Call switching
device
for NEM-10A/C,
20A/C
m P.94
100-call master
100-call master
NBJ-40(*2)
NBJ-40B(*2)
NEM-110
NEM-110A
110-call master
110-call master
NEM-120
NEM-120A
120-call master
120-call master
Call switching
device
for NEM-30/C,
40/C
m P.94
Call switching
device
for NEM-30A/C,
40A/C
m P.94
(*1 ) NA-T/A: Not available in Europe, Australia, nor New Zealand
NEW-5
IER-2
Dual master
call adaptor
m P.94
Call extension
m P.97
(*2) NBJ-20/40, NBJ-20B/40B: Not available in Europe
Unit dimensions
NEM-20/C
NEM-40/C
N
+
–
N
+
–
346
446
596
496
NA-A, AN
NA-NE
NEM-120
NEM-80A
• NA-NE
142
NA-NE
NA-A
NA-AN
NAR-6A
A
B
C
D
E
RD
OG
115
No.
NAR-6A
NA-T/A
NE-JA
OG/WH
BLx2
BL
GR
BK
83.5
No.
116
10
(2-gang)
94
• NB-L
NB-L
No.
E
RD
BK
NAR-6A
GR
105
Specifications (NEM-40A/C)
Power source
Power supply
Communication
BL
OG
OG/WH
BLx2
1. Power supply requirements
One power supply for up to 40-call master
Two power supplies for 50- to 80-call master
Three power supplies for 80- to 120-call master
2. Adding call button to NA sub stations
RD: Red BK: Black GR: Green BL: Blue OG: Orange
OG/WH: Orange/White
N : PS2420S, PS-2420UL, PS-2420
74
68
160
E
E
BLx2
185
220
2.
• NA-A, NA-AN
176
140
169
N
N
NEM-20A/C
NEM-40A/C
232
N
1+
1–
2+
2–
1+
1–
140
260
1.
260
Wiring
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Lineup
Output
Wiring
Distance
24V DC, 45W max. 2.5W standby (NEM-40/C)
PS-2420S, PS-2420UL, PS-2420 (40-call)
Sub calls in w/tone & LED latching at master. Press
TALK button to transmit, release to listen, or lift
handset. At sub, pretone and voice when selected.
Talk hands-free.
Press ALL CALL button to activate all sub stations.
500mW max., adjustable.
All Call: 6W, 12W.
Selectively up to 10 subs w/TALK: 3W
2 wires per sub, non-twisted (1 common + no. Subs)
NEM to NA subs 130m(0.65mma) 200m(0.8mma)
78
Master / Sub Intercom
MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
100 TC-M
2
Master station
TC-20M
20-call master
TC-10M
10-call master
TC-20M + TC-40G
60-call
Wiring
Features
l Expandable internal telephone intercom
l One or dual master configuration
l Tone & LED call-in, staying on until answered
l Additional buzzer at TB-SE (w/relay)
l TRANSFER button on TC-M for communication between two
TB-SE subs
TC-10M
TC-20M
Communication network
TC-40GS
TC-20G
TC-40G
TB-SE
TC-20M
The TC-40GS is equipped with socket to connect the second add-on selector
TC-20G or TC-40G.
Specifications (TC-M)
TB-SE
Power source
*TB-SE
Consumption
Power supply
Communication
TC-20M
*TB-SE : Sub station for two-master call.
Wiring
Distance
Unit dimensions
TB-SE
480
405
330
255
210
230
210
83.5
115
80
555
630
79
72
18V DC, 350mA.
15~16V AC, 50/60Hz, 750mA.
6W. 3W standby.
PS-1820S, PS-1820UL, PS-1820, AC transformer.
Pick up TB-SE handset. Rings TC-M, w/tremolo & LED,
staying. At TC-M, pick up and press a lit selector to
reply.
2 parallel wires per TB-SE, non-polarized.
TC-M’s 200m(0.65mma) 480m(1.0mma)
TC-M~TB-SE 400m(0.65mma) 900m(1.0mma)
Lineup
Sub station
IER-2
Call extension
m P.97
TC-20G
20-call add-on selector
TAR-3
TB-SE
External signaling
relay
m P.98
Sub station
Power supply
PS-1820S
PS-1820UL
PS-1820
TC-40G
40-call add-on selector
TC-40GS
m P.100
W/add’l 20-/40-call expansion
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Add-on selector
Wiring 2
Wiring 1
900m / 1.0mma
480m / 1.0mma
TB-SE
TC-M
2
900m / 1.0mma
TB-SE
TC-M
2
3
TB-SE
2
2
2
TB-SE
2
2
2
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
E
E
3
E
E
3
E
4
E
E
5
5
E
E
E
E
6
6
7
7
E
E
E
M
C
E
M
C
+
- 12V
T
S
R S
1
E
IER-2
5
2
1
2
1
2
2
TB-AD1 5 (x3)
TB-AD1
TB-AD1
2
19
20
+
–
T
R
N
+
–
T
R
8
E
S
TC-20M
TB-AD1
2
2
2
E
2
TC-20M
10
+
12V T
S R
2
2
E
9.TB-SE
E
E
1 TB-SE
2
1
2
1
2
1
2
1
2
1
2
1
2
9
1
2
E
10
1
2
4
9
TB-AD1
E
U
U
2
8
2
IF-DA
2
IF-DA
IF-DA
IF-DA
TB-AD1
1
E
IER-2
l Run 2 parallel wires per TB-SE. Use any E terminal for max. three TB-SE’s.
l Do not parallel TB-SE sub wires, or door station wires (in dual-TC-M system).
80
Master / Sub Intercom
DOOR
ROOM
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
1 TC-M & TB-AD10
10
Door station
Master station
Door adaptor
Lineup
IER-2
Call extension
m P.97
TB-AD1
IF-DA
1-call door adaptor
Door station
m P.30
TC-10M
10-call master
TAR-3
TC-10MD*
External signaling
relay
m P.98
TB-AD10
10-call master
for door release
*Not available in Europe
10-call door adaptor
Power supply
PS-1820S PS-1820UL PS-1820
TB-ADD*
10-way door release adaptor
*Not available in Europe
m P.100
Features
EL-12S
Electric door strike
m P.97
Wiring
l Single or multiple audio door communication, expandable
l Optional selective door release control
IF-DA
TB-AD10
TC-10MD
TB-ADD
EL-12S
2 (x10)
Communication network
2
NP
PT
11
IF-DA
TC-M+TB-AD10
1.
2.
1
2
D1
1
2
D2
1
2
D3
1
2
D4
1
2
D10
TB-ADD
10.
EL-12S
( 10)
M
Pre-tone sounding or mute selectable at TB-AD10.
E
E
E
TB-AD10
E
10
10
D10
DE
D10
DE
12V
12V
T
R
T
R
150
L2
L2
L3
L3
L10
L10
EL-12S
TC-20M + TC-20G
TB-AD10
1
97
Wiring
T
TC-20M
TB-AD1
L1
L1
L4
L4
U
230
83.5
140
42
2
D1
D2
D3
D4
TB-AD10
2
TB-AD10
3
IF-DA
D1
D2
D3
D4
PRE-TONE
ON OFF
IF-DA
74
1
2
3
4
E
Unit dimensions
TB-AD1
1
2
3
4
2
10
5
2
2
10
IF-DA
10
Multiple TB-AD10 installation; Add a power supply for TB-AD10 #3 or after.
1
2
1
2
N
+
–
T
R
2
U : PS-1820S, PS-1820UL, PS-1820
Specifications (TB-AD10)
U
TB-AD1 5 (x3)
TB-AD1
TB-AD1
2
19
20
+
–
T
R
2
Wiring
TC-20M
IF-DA
81
IF-DA
Power source
Door capacity
Communication
IF-DA
Distance
TB-AD10: 12V DC, supplied by TC-M.
10(TB-AD10). 1(TB-AD1).
Door calls in w/tremolo & LED 40 sec. Pick up and
depress LED lit selector. Pretone sounds at door, or
silenced.
2 parallel wires to door, non-polarized.
4 common + no. doors, TC-M to adaptor.
TC-M to TB-AD10 65m(0.65mma) 150m(1.0mma)
TB-AD10 to IF-DA 150m(0.65mma) 360m(1.0mma)
Market-Com
STATION
Market-com station
Market-com adaptor
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
60 MC-60/4A
Lineup
Paging speaker
w/built-in transformer
(locally available)
MC-A/A
Zone page adaptor
MC-60/4B
Market-Com desk station
*Not available in Europe
Power supply
PS-2420S PS-2420UL
PS-2420 m P.100
MC-60/4A
Market-Com station
Features
Wiring
l Max. 60-station paging & communication system
l Selective 4 talk channels with in-use LED’s
l Conference call among 3 stations
l Music cutout during paging
l Reinforced modular coil cord
MC-60/4A
10
3
7
2
7
S
1
7
7
1
7
2
7
3
7
MC-60/4A
10
7
#1
#2
MC
Communication network
7
7
7
7
7
7
7
7
#3
#4
MC-A/A
A
G
M
(1)
MC-60/4A
MC-60/4A
(2)
Ch.1
Ch.4
(1) Paging (2) Select a channel 1~4 paged, and communicate.
Unit dimensions
MC-60/4A
#1- 10
3
2
1
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1/+
2
3
4
5/–
6
7
N
MC-A/A
1
2
3
10 -#2
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
#3~#6
143
83.5
234
Station blocks #1~6 of max. ten MC-60/4A’s
N : PS-2420S, PS-2420UL, PS-2420
Specifications (MC-60/4A)
91
90
51.5
94
Specifications (MC-A/A)
Power source
Amp. input
Music soursce output
24V DC, PS-2420S, PS-2420UL, PS-2420
AUX 10Kd, 0.3V~0.5V
Range 100mV~1.2V, 10Kd or less
Power source
Power supply
Communication
Talk channel
Wiring
Cable specified
Distance
24V DC, 70mA max. (in page).
PS-2420S, PS-2420UL, PS-2420 at MC-A/A.
Pick up and depress channel selector 1~4 and page
w/PAGE button. Called party picks up and presses lit
LED channel button.
4 and a separate paging channel.
7 wires in loop, non-twisted.
Line capacitance less than 25pF/30cm.
MC-A/A to MC-60/4A(*) 500m(0.65mma)
750m(0.8mma)
Total wiring distance 1500m(0.65mma, 0.8mma)
(*) MC-A/A to farthest MC-60/4A, or between two farthest MC-60/4A’s of
different blocks.
82
Mid-Power Intercom
MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
3 MP-S
1
Master station
Sub station
Lineup
N-EA*
NBZ-M*
Surface round
frame
Flush square
frame
NP-W*
Surface mount
box
for NP-B
AS-3N
Sub station
MP-1S
MP-3S
1-call master
3-call master
8d horn speaker
locally available
Call button
Power supply
PS-1225S
PS-1225UL
PS-1225
AS-3A
NP-B
Sub station
Flush call plate
m P.99
*Not available in Europe
Features
Wiring
l 1 or 3-call mid-power intercom, 2.5W powered
l Incorporates subs either in console, ceiling mount or 8d horn for
maximum output
l Hands-free reply from sub
MP-1S
150m / 0.8mma
2
MP-1S
8ohm
2
NP-B
1
E
T
Communication network
8ohm
BL
+
-
RD
MP-3S
MP-1S
MP-1S
MP-3S
8Ω
2x3
AS-3A
2
AS-3N
2
2
8ohm
NP-B
1
E
MP-3S
AS-3A
2
E
AS-3N
NP-B
NP-B
BL
★
3
E
NP-B
T
8d Horn w/talkback reply
NP
+
-
BL
8ohm
RD
l For 8d horn without NP-B, install a 33MFD, 25V NP capacitor on No. line.
BL : Blue(2) RD : Red(2) ★NP-25V Capacitor T : PS-1225/S/UL
Unit dimensions
MP-1S
MP-3S
Specifications (MP-S)
AS-3A
43
83.5
169
177
83.5
Power source
Power supply
Communication
78
83
NP
1
E
8Ω
MP-3S
148
NP
142
41
Output
Output impedance
Wiring
74
Distance
12V DC, 1A.
PS-1225S, PS-1225UL, PS-1225
Sub calls in w/tone (& LED 20 sec. on MP-3S). Press
sub selector and TALK to transmit, and release to
listen.
2.5W at 1KHz.
8d
2 parallel wires per sub, non-polarized.
*Do not make E wires common.
MP-S to sub 100m(0.65mma) 150m(0.8mma)
High-Power Intercom
MASTER
SUB
Master station
Sub station
Call button
Lineup
NP-W*
Surface mount
box
for NP-B
NP-B
Flush call plate
AS-3N
Sub station
NBZ-M*
Flush square
frame
for AS-3N
AP-5M
5-call master
AP-10M
10-call master
(Photo)
N-EA*
Surface round
frame
for AS-3N
AS-3A
AP-1M
Sub station
1-call master
*Not available in Europe
Features
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
10 AP-M
2
Wiring
l 10 watt-powered paging & communication system
l Selective all call to 5 subs
l Single or dual-master configuration
l 8d or 16d horn speaker with talkback
2
2
NP-B
2
AS-3N
Communication network
7
(1)
AP-10M
(1)
AP-10M
1
E
NP-B
AS-3N
3
E
4
E
4
E
5
E
5
E
C
E
10
E
10
E
R
C
E
R
GND
GND
Unit dimensions
140
BL RD
BL
1
E
RD
240
253
AP-5M, AP-10M
1
E
3
E
(1) 8d horn
NP25V
33μF
AP-10M
2
E
AS-3A
114
P.
2
E
NP-B
AP-1M
3P(2P+1)
AP-10M
AS-3A
NP-B
BL : Blue(2). RD : Red(2).
276
196
41
74
NP-B
180
169
142
Power source
Consumption
Communication
115
AS-3N
83.5
AS-3A
Specifications (AP-M)
15
47.5
70
16
27
Wiring
Distance
110~125V, 127V, 230V, 220~240V AC, 50/60Hz.
45W. 6W standby.
Sub calls in with tone & LED, 15 sec.
Depress selector and use Talk/Listen switch. All call
selectively to max. 5 subs. Max. 10W transmit,
adjustable.
300mW receive, adjustable.
1 twisted pair per sub, non-polarized
3 pairs (5), masters.
AP-M to sub 150m(0.65mma) 230m(0.8mma)
84
Nurse Call
MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
80 NHX
1
Master station
*Not available in Australia, nor New Zealand
Add-on selector
Central control unit
NHR-SP
Duty station
NHX-80X
Central control unit
NHX-50M
50-call master station
NHX-30G
Zone light
30-call add-on selector
Plugs into NHX-50M
NHR-30K
30-call add-on trunk card
NHR-3A-4
Power supply
PS-2420S PS-2420UL PS-2420 m P.100
Features
l One master, up to 80 sub stations. Single and dual patient stations
l Multi-station capability per patient room
l Three types of call-ins from patient stations: Routine call, Bathroom
call & Cord-out trouble call, identified by tone & blinking LED
(w/priority according to urgency and time of call)
l NHR-3TS Common Area Call station is used for common area
bathroom call or staff call (urgent)
l Optional zone light (max. 4)
4-zone call light
Communication network
NHR-4A/A
Duty station
NHR-SP
NH-2SA/A
NHR-7A
Tone &
LED
Communication
1. At NHX-50M master, when called by a bedside sub, either lift
handset or press TALK once to establish talk channel. To initiate
a call, press the selector button of the sub. At the sub, pretone
sounds and TALK is lit green. Corridor and zone lights do not
turn on.
To silence the tone, press TONE-OFF button. Tone will resume
after 90 seconds or when new call is placed.
2. Corridor lamp & Zone 1~4 light turn on with any type of call
placed by sub station area. When talk channel is established,
two lights will turn off.
3. A call from NHR-3TS is of the same level as Urgent bathroom
call. (no verbal communication)
Patient rooms
NH-1SA/A
Blinking
NHR-4A/A
• Routine call, Urgent bathroom call
or Cord-out trouble call
Tone &
LED
NHR-4A/A
NH-2SA/A
NHR-7A
Common area restrooms
NHR-7A
NHX-50M
NHX-30G
(up to 3)
NHR-3TS
(max. 4)
1
2
NHR-3A-4
Lights on for
any call
NHR-7A
3
4
• Urgent bathroom
call
NHR-3TS
• Urgent staff call
85
Duty station
Staff call area
NHR-7A
(up to 3)
Corridor lamp
NH-1SA/A
NH-2SA/A
NHR-3TS
NHR-4A/A
Single-jack bedside sub station
Dual-jack bedside sub station
Calling zone light
Corridor lamp w/red &
white lamps
NHR-8B
NHR-DP
NHR-7A
NHR-7A
Bedside call switch
Dummy plug
Staff call switch
Bathroom pullcord
Call tone & light annunciation
TYPE OF CALL
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Sub station
Wiring
TONE
LIGHT
Single chime,
every 6 sec.
—
Blinking, every
2 sec.
‘CALL’ steadily lit
White lamp
steadily lit
Routine call
At NHX-50M (& at Duty station)
At Bedside sub
At Corridor lamp
—
NHR-4A/A
Sub trunk line
(max. 10 subs)
NH-1SA/A
3P
NHR-4A/A
NH-2SA/A
NHR-7A
3
NHR-4A/A
Single chime,
every 2 sec.
Double blinking,
every 1.8 sec.
At Bedside sub
—
‘CALL’ steadily lit
At Corridor lamp
—
Red lamp
Blinking
NHR-7A
20m NH-1SA/A
3
3
3P
NHR-7A
3
Cord-out trouble call
NHR-7A
3
3
Single chime,
every 0.5 sec.
Blinking fast,
every 0.4 sec.
At Bedside sub
—
‘CALL’ steadily lit
At Corridor lamp
—
White lamp
Blinking
3
2
NHR-7A
3P
3
3P
1
5
1
2
1
3
4
5
PS
2
1
3
4
NHR-3TS in common area
Staff call (urgent)
—
Red blinking
(2 lamps)
White blinking
(one lamp)
5m PS
PS
2
1
3
5
PS
5
4
2
5
50m
3
4
(max.4)
20m
5P
—
20m
......
NHX-80X
CCU
Bathroom call (urgent)
20m
NHR-7A
3
20m
NHR-3TS
3P
At NHX-50M (& at Duty station)
50m up to
farthest sub.
Max. 100m
per block.
3P
Urgent bathroom call or
NHR-3TS
NH-1SA/A
3
3
At NHX-50M (& at Duty station)
NH-1SA/A
3
20m
NHR-SP
NHX-50M/NHX-30G
PS : PS-2420/S/UL
Line-off trouble at NHX-50M
Line-off at bedside sub
Line-off at Duty station
Slow buzzer,
intermittent
Faster buzzer,
intermittent
Lit 0.2 sec.,
every 2 sec.
No light
Sub trunk line: 6 wires (3P). 4P with NHR-3A-4 light included.
Each zone requires a separate common wire from NHX-80X.
Use twisted pairs with an overall shield, low capacitance, 0.65mm dia.,
solid conductors. (Rated capacitance level of wire: 25pF/30cm or less)
86
Nurse Call
NHX Components
*Not available in Europe, Australia, nor New Zealand
NHX-80X
Central control unit
Features
Specifications (NHX-80X)
Controls the NHX-50M
and up to 80 sub
stations. 1 ~ 8 trunk lines
of up to 10 stations per
trunk connected inside
CCU. (3 pairs, or 4 pairs
if zone light is installed).
5 pairs to Master station.
Terminates in CCU Zone
light (4 in loop), Duty
station, and power
supplies(2).
After installation, the
NHX-80X must be
initialized. During use,
turn power switch off and
back on to reset.
Install NHR-30K
Expansion Trunk Card
when NHX-30G is used.
Power Source
Power supply
Station capacity
Calling
Communication
Call-in priority
Warning tones
Wiring
Unit dimensions
NHX-80X
Wiring distance
460
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Central control unit
NHR-30K
30-call add-on trunk card
Mounting
340
98
24V DC, 4A max.
2 pcs PS-2420S, PS-2420UL, PS-2420
50 sub stations (max. 80 with NHX-30G & NHR-30K).
Routine call, Urgent bathroom call & Cord-out trouble call.
Up to 5 calls can be displayed on NHX-50M.
Single and private talk channel. Press-to-talk or handset
voice-actuation
(1) Cord-out trouble call, (2) Urgent bathroom call and
NHR-3TS common area bathroom call or staff call, (3)
Routine call. Subs’ call-ins on standby connected according
to urgency level and time of call.
(1) Line-off trouble at Bedside or NHR-3TS sub & Duty
station. (To stop tone on the Duty station, plug in, 2-pin
jumper to CN104 in CCU).(2) 90 sec. elapse timer: Call tone
goes up to HIGH level.(3) 90 sec. off-hook timer: Steady
tone will notify that handset is off-hook.
3 (or 4*) twisted pairs, CCU to Sub trunks 1~8. (*when
zone light is installed)
5 twisted pairs, CCU to NHX-50M.
6 wires (parallel), CCU to NHR-SP.
5 wires (parallel), CCU to NHR-3A-4.
Use twisted pairs with an overall shield, low capacitance,
0.65mm dia., solid conductors. (Rated capacitance level
of wire: 25pF/30cm or less)
CCU to Sub (farthest) 50m(0.65mm)
Sub trunk line 100m(0.65mm)
CCU to NHX-50M 20m(0.65mm)
CCU to Duty station 20m(0.65mm)
CCU to Zone light 50m(1.0mm)
CCU to PS-2420UL 5m(1.0mm)
3-gang wall-mounting. Or inside Electrical Enclosure with
secured door (Provide a suitable, non-combustible
mounting surface).
Master station
Features
NHX-50M
50-call master station
Unit dimensions
NHX-50M
210
NHX-30G
210
Extremely compact 50-call desk console.
Open voice communication with TALK
button, or handset (voice-actuated). When
called, simply press TALK or pick up handset
to establish channel. Otherwise, press TONEOFF button and go to calling location. To
initiate a call, press a selector button first.
NHX-30G is a 30-call add-on selector. Plugs
itno NHX-50M.
280
94
90
58.5
Specifications (NHX-80X)
Wiring
NHX-30G
30-call add-on selector
Distance
10-pin plug in connector (to NHX80X). Provided with preset volume
controls. Can verify connection of all
sub stations.
Install within 20m from CCU.
Duty station
Features
Specifications (NHX-80X)
Acknowledges any station call with tone and
blinking LED. Go to the NHX-50M. Press
TONE-OFF and identify the caller at Master
station.
Mounting
Wiring
Unit dimensions
120
NHR-SP
NHR-SP
Duty station
116
87
46
2-gang semi-flush mounting.
CN1 (6 pin) to NHX-80X. When NHRSP is installed, unplug Connector
from CN104 on NHX-80X.
NH-1SA/A
NH-2SA/A
Single-jack bedside
sub station
Dual-jack bedside
sub station
Features
Specifications
Bedside station for calling and
communication. Used with NHR-8A call
cord. When call button is pushed, iCALLj
LED is lit red. When master replies, green
iTALKj LED is lit. Press CANCEL to reset
the call. When NHX-50M calls in, pre-tone
sounds and iTALKj LED is lit green.
Dummy plug (NHR-DP)
Plugs into jack unused on bedside sub
stations.
Mounting
Wiring
2-gang semi-flush mounting
Sub Nos. 1 ~ 10 setting on
SW1.
CN1 (6 pin) to sub trunk
line.
CN2 (8 pin) for NHR-7A,
NHR-4A/A & zone light.
Unit dimensions
120
NHR-8B
NHR-3TS
NHR-3TS
120
NH-1SA/A, NH-2SA/A
Bedside call switch
Calling zone light
116
46
116
28 45
NHR-DP
Dummy plug
Bathroom pullcord
NHR-7A
Staff call switch
Mechanically locked calling device, used to
place an urgent bathroom call from a patient
room, common area bathroom or staff call
location. Cannot be used alone, and must be
used with NH-1SA/A, NH-2SA/A, or with
NHR-3TS common area call station.
Provides dry closure contact. Master-CALL
LED indicates call placed.
Ratings 24V DC, 100mA (min. 5mA or
more).
Unit dimensions
NHR-7A
115
Features
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Bedside sub station
71
10
Specifications
Wiring
Distance
Single-gang semi-flush mounting.
3 wires to patient station or NHR-3TS.
Corridor lamp
When a call is placed, the NHR-4A blinks red
or is steadily lit white.
Ratings: 24V DC (or more), 200mA max.
Unit dimensions
NHR-4A /A
120
Features
70
NHR-4A/A
27
Specifications
Corridor lamp w/red &
white lamps
Wiring
Distance
Single-gang semi-flush mounting.
3 wires to Bedside sub station.
Zone light
NHR-3A-4
4-zone call light
Unit dimensions
NHR-3A-4
46
Zone lamp turns on when any call is placed
on the system, indicating which zone has a
call placed. Up to 4 zone lights can be
installed in one system. Install one
PS-2420S, UL for every 2 zone lights.
Lamp ratings: 24V DC ~, 200mA.
120
Features
438
88
Nurse Call
NHX-80X
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
51
52
53
54
55
56
A
NH-1SA/A
NH-1SA/A
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
ZL
ZL
ZL
11
12
13
14
15
16
Z3
Z1
61
62
63
64
65
66
21
22
23
24
25
26
71
72
73
74
75
76
31
32
33
34
35
36
Z4
81
82
83
84
85
86
NH-1SA/A
D
1
2
NHR-3A-4
1
3
2
3
4
OR
YL
RD
GR
BL
RD
4
NHR-3A-4
NHR-3A-4
1
1
2
3
2
+
---
+
---
G
G
PS-2420S
WL
WL
RL
E
RL
E
TC
TL
E
TC
TL
E
2 NHR-4A/A
RD
OG
R1
R2
ZL
LC
R3
R4
RC
E
PR
GY
ZL
LC
NHR-7A
YL
BL
GR
BL
PS-2420S
NHX-50M
DS1
DS2
DS3
DS4
DS5
DS6
A Patient rooms w/a single bedside sub station
B Staff call (corridor)
C Bathroom call (common area)
D Patinent rooms w/multiple bedside sub stations
E Corridor lamp NHR-4A/A
1 : Two white lamps 2 : One red lamp
NHR-4A 2 is required only when NHR-7A bathroom
pullcord is installed in a single and common bathroom.
89
1
2
3
4
5
6
BR
OG
RD
OG
6 (parallel)
NHR-SP
1
2
3
4
5
6
41
42
43
44
45
46
4
OR
YL
RD
GR
BL
RD
OR
YL
RD
GR
BL
RD
OR
YL
RD
GR
BL
RD
3
4
NH-1SA/A
Z2
1 NHR-4A/A
NHR-3A-4
NH-1SA/A
S1
S2
S3
S4
S5
S6
PS24
A+
A-
PS24
B+
B-
M1
M2
M3
M4
M5
M6
M7
M8
M9
M10
NHX-30G
M1
M2
M3
M4
M5
M6
M7
M8
M9
M10
PS24: PS-2420S, PS-2420UL, PS-2420
Wire color identifications
NHR-3A-4
OR: Orange (Zone 1)
YL: Yellow (Zone 2)
RD: Red (+)
GR: Green (Zone 3)
BL: Blue (Zone 4)
RD: Red (+)
Zone light relay makes
contact.
NHR-4A/A
BR: Brown
OG: Orange
RD: Red
OG: Orange
NHR-7A
YL: Yellow
BL: Blue
GR: Green
BL: Blue
NH-1SA/A
BR: Brown
RD: Red
OG: Orange
YL: Yellow
GR: Green
BL: Blue
PR: Purple
GY: Gray
NHR-3TS
BR: Brown
RD: Red
OG: Orange
YL: Yellow
GR: Green
BL: Blue
PR: Purple
C
NHR-3TS
NHR-3TS
NHR-7A
1
2
3
4
5
6
WL
RL
E
TC
TL
E
ZL
PR
GY
1
2
3
4
5
6
BR
RD
OG
YL
GR
BL
PR
BR
OG
RD
OG
YL
BL
GR
BL
NHR-4A/A
1
2
3
4
5
6
WH
TC1
TL1
BR
RD
RD
E
OG
TC2
TL2
YL
GR
BL
NHR-7A
YL
BL
GR
BL
NHR-7A
ZL
TC1
TL1
BR
RD
E
OG
TC2
TL2
ZL
NH-1SA/A
NH-1SA/A
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
WL
WL
WL
WL
RL
E
RL
E
RL
E
RL
E
TC
TL
E
TC
TL
E
TC
TL
E
TC
TL
E
ZL
LC
PR
GY
ZL
LC
PR
GY
YL
BL
GR
BL
BL
PR
NH-1SA/A
PR
GY
YL
BL
GR
BL
YL
GR
NH-1SA/A
ZL
LC
NHR-7A
YL
BL
GR
BL
YL
BL
GR
BL
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
B
NH-1SA/A
ZL
LC
Multi-station patient room applications
Multiple NH-1SA/A and NH-2SA/A bedside sub stations can be installed within a patient room,
observing the following conditions;
1. Max. 6 bedside sub stations may be connected per room for max. 12 calls (when NH-2SA/A
stations are used).
2. A corridor lamp inside (NHR-4A) must not be connected with more than 4 bedside sub stations.
3. Due to the above, install two NHR-4A/A corridor lamps when more than 4 sub stations are in one
room, i.e. two WHITE lamps used in one NHR-4A/A, and one RED bulb used in the other NHR-4A/A.
4. NH-1SA/A and NH-2SA/A station numbers must be programmed in numerical order and connected
to the same subs trunk line.
5. NHR-7A bathroom pullcord is optional.
90
Nurse Call
MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
120 NEM
1
Master station
Sub station
NEM-10/C
NEM-10A/C
10-call master
10-call master
NEM-20/C
NEM-20A/C
20-call master
20-call master
NA-A
Sub station
NA-AN
Privacy sub station
NEM-30/C
NEM-30A/C
30-call master
30-call master
NEM-40/C
NEM-40A/C
40-call master
40-call master
Features
Power supply
PS-2420S PS-2420UL
PS-2420 m P.100
Wiring
l Lamp memory intercom: Sub’s call-in with tone & light
l Press-to-talk or handset with voice actuation
l Selective or group call of 10 subs
l All Call
l Pre-tone sounding at sub, when selected
l Optional accessories for health care applications
l Expand beyond 40 stations with 50-120-call master stations
NA-A/AN
NA-NE
NA-A/AN
2
2
2
2
2
2
NB-L
1+n
1+n
2
NBY-1A
(1)
2
(2)
2
NBY-4A
NBY-4A
2
NEM-40A/C
(3)
(1)
(2)
(2)
NB-L
NA-A
NA-A
NA-A
NA-A
(3)
NBR-7AS-S
(4)
(5)
(1) All call for instant transmission to all subs
(2) Selective call up to 10 subs or individually
(3) Subs call-in w/tone & LED staying with corridor light on
(4) NBR-7AS-S: Bathroom pullcord in a patient room
(5) Multi-substation patient room
91
NAR-2A
l 1 + n = 1 common + no. of Subs
NEM-40A/C
NEM-40A/C
NBR-7AS
2
3
2
Communication network
NBR-8A
3
NBJ-20(*2)
IER-2
NAR-6A
NBY-4A
NAR-3
Call switching
device
for NEM-10/C,
20/C
m P.94
Call button
Corridor call
light
Round corridor
light
NBJ-40(*2)
Call extension
m P.97
NB-L
NE-JA
Ceiling sub station
Flush sub
station
NR-4AS13(*1) B
Call switching
device
for NEM-30/C,
40/C
m P.94
NB-U
Music adaptor
m P.94
NBJ-20B(*2)
NA-NE
Sub station
NA-T/A(*1)
NEW-5
NAR-2A
NBY-1A
Metal jack for
bedside call
switch
Dual master call NBJ-40B(*2)
adapto
Call switching
m P.94
device
for NEM-30A/C,
40A/C
m P.94
Call reset button
NBR-8A
Bedside call
switch
Handset sub
station
NBR-7AS-S(*1)
NBR-7AS
Bathroom pullcord,
moisture-resistant
(*1 ) NA-T/A, NBR-7AS-S, NR-4AS13: Not available in Europe, Australia, nor New Zealand
Wiring
Call switching
device
for NEM-10A/C,
20A/C
m P.94
B
(*2) NBJ-20/40, NBJ-20B/40B: Not available in Europe
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Lineup
Wiring
NEM-40A/C
NEM-40A/C
E
1
2
3
4
5
9
10
E
A
B
C
D
E
NBY-4A
1
2
3
4
5
6
7
8
9
10
NA-NE
NA-A
RD
BK
GR
OG
OG/WH
BL
NBY-4A
NBR-7AS-S
(SOP)
BL
N
+
–
(2)
NBY-1A
BLx2
BLx2
E
RD
BK
GR
BL
OG
OG/WH
RD
BK
GR
BL
NBY-1A
NBY-4A
NBR-7AS
x2
BLx2
NBY-4A
NAR-2A
11
12
13
14
15
16
17
18
19
20
NBR-7AS
IER-2
S
S
RD
BK
GR
BL
OG
NAR-2A
NB-L
39
40
1
E
X
BL
NAR-2A
E
31
32
33
34
35
RD
BK
GR
BL
OG
OG/WH
NBY-4A
BLx2
NAR-2A
(1)
NB-L
NBR-8A
Health care application
l Up to three NBR-7ASs can be connected in parallel.
RD : Red BK : Black GR : Green OG : Orange OG/WH : Orange/White BL : Blue
N : PS-2420S, PS-2420UL, PS-2420
PS24
+
—
A
B
C
D
E
(3) BL
NR-4AS13
(SOP)
BL
BLx2
A
B
C
D
E
A
B
C
D
E
A
B
C
D
E
(4)
NA-A,
NA-AN
NAR-2A
Bathroom pullcord within a patient room
(1) NBR-7AS-S: Call-in from NBR-7AS-S can be cancelled only with NAR-2A Call
reset button.
Press on upper end of Call button on NBR-7AS-S to release the call.
(2) Cut GREEN wire.
Multi-substation patient room
(3) NR-4AS13: NBY-4A corridor call light may hold up to three NA sub stations.
Use NR-4AS13 for more than three NA sub application.
(4) Remove the D - E link on each NA sub station.
N : PS-2420S, PS-2420UL, PS-2420
92
Nurse Call
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Lineup
IER-2
Call extension
m P.97
NEM-60A
60-call master
Unit dimensions
NEM-60A
60-call master
60-call master
NB-U
NEM-70
NEM-70A
70-call master
70-call master
Music adaptor
m P.94
NEM-80
NEM-80A
80-call master
80-call master
NEM-90
NEM-90A
90-call master
90-call master
NEM-100
NEM-100A
100-call master
100-call master
NEM-110
NEM-110A
110-call master
110-call master
NEM-120
NEM-120A
120-call master
120-call master
176
140
NEM-40A/C
260
260
746
896
1046
1196
15
47.5
NA-NE
142
340
74
83.5
82
Specifications (NEM)
Power source
70
NAR-6A
NAR-2A
55
Power supply
Communication
83.5
120
115
83.5
NBY-1A
70
43
NE-JA
23
3
10
(2-gang)
94
Output
Wiring
Distance
232
83.5
NA-T/A
115
95
*NEM-n/7.A width : Reduce 100mm (handset part) for each sized station.
120
185
220
NBY-4A
68
211
180
169
83.5
NA-A/AN
160
176
140
NEM-50A ~ NEM-120A
446
596
NB-L
93
50-call master
NEM-60
260
140
346
496
116
NEM-50A
50-call master
Unit dimensions
NEM-40/C
70
NEM-50
105
24V DC, 45W max. 2.5W standby (40-call)
24V DC, 180W max. 7.5W standby (120-call)
PS-2420S, PS-2420UL, PS-2420 (40-call)
Open voice press-to-talk or handset voice actuated.
Sub calls in w/tone & LED latching at master. Press
TALK button to transmit, release to listen, or lift
handset. At sub, pretone and voice when selected.
Talk hands-free.
Press ALL CALL button to activate all sub stations.
500mW max., adjustable.
All Call: 6W, 12W. 24W (120-call)
Selectively up to 10 subs w/TALK: 3W
2 wires per sub, non-twisted (1 common + no. Subs)
NEM to NA subs 130m(0.65mma) 200m(0.8mma)
Features
NBJ-20*
Call switching device
NBJ-40*
Call switching device
NBJ-20B*
Call switching device
NBJ-40B*
Call switching device
*Not available in Europe
l Switches all NA sub wiring
from one master to the other
to route all call-ins to the
master on duty.
l NBJ-20 & NBJ-20B are
equipped with a rotary
switch, and NBJ-40 &
NBJ-40B with two rotary
switches.
l When the rotary switch is put
to 1 position, all the sub
wiring is connected with
Master station(M1). To
switch the sub wiring to
Master station(M2), put the
rotary switch to 2 position.
Wiring
NEM-20/C
NEM-20/C
1 2 3 4 ... n E
1 2 3 4 ... n E
1 2 3 4 ... n E
M1
1 2 3 4 ... n E
M2
M1 : Master station 1.
M2 : Master station 2.
S : Sub station.
S
1 2 3 4 ... n E M
NA-A, AN, NE, NB-L
NBJ-20
NBJ-20B
(*)Terminal M
remains unused.
(on NBJ-20B)
Used for
NBJ-20 for NEM-10/C & NEM-20/C
NBJ-40 for NEM-30/C & NEM-40/C
NBJ-20B for NEM-10A/C & NEM-20A/C
NBJ-40B for NEM-30A/C & NEM-40A/C
Music adaptor
Features
l Distributes music to all subs
with auto mute while
communicating.
l When NEM includes NEW-5
adaptor(s), NB-U cannot be
used.
Wiring
NA-A/AN/NE
NB-L
NEM-40A/C
1
2
3
4
5
6
7
8
9
10
Used for
NEM-n/C, NEM-nA/C
(n = 10 ~ 40)
NB-U
B
Y
B
Y
A1
V1
A1
V1
A2
V2
A2
V2
A3
V3
A3
V3
A4
V4
A4
V4
E
E
40
E
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Call switching device
BGM
8Ω
8Ω
l As shown, connect NB-U to 8 Ohm output of Amplifier with twisted pair wires.
l Remove jumpers between A1~V1, A2~V2,A3~V3, A4~V4 on master station.
l Amplifier requirements: Input: 100mV for rated output. 10W w/8d output or
10W w/4~16d output.
l Do not use 1Kd output on the amplifier.
NB-U
Music adaptor
Specifications
Power source
Permitted input
Wiring
Distance
6V DC, supplied by NEM.
5W. 10W at its peak.
3 wires commom + 2 per 10-call (max.11).
NB-U to NEM 10m(0.65mma) 15m(0.8mma)
NB-U to Amp. 75m(0.65mma) 115m(0.8mma)
Dual-master call adaptor
Features
l Common NA subs place a call
ringing two NEM masters.
l One NEW-5 req’d for every
five subs calling both
masters. Eight NEW-5 for 40
sub stations, can be powered
with one PS-1225S.
NEW-5
Cabling
NA-A/AN/NE
NA-A
NEM-40A
2xNA
NEW-5
4+1xn
N
T
NEM-40A
4+1xn
36
NA-A/AN/NE
2xNA
N
40
Used for
T : PS-1225/S/UL
NEM-n/C, NEM-nA/C
(n=10~40)
Specifications (NEW-5)
Power source
Power supply
Capacity
Dual master call adaptor
Communication
Wiring
Distance
N : PS-2420/S/UL
12V DC
PS-1225S, PS-1225UL, PS-1225
5 subs per NEW-5.
Max. 8 adaptors for NEM-40(A)/C.
Separate channel for ea. master.
2 wires, NEW-5 to sub.
NEW-5 to sub 130m(0.65mma) 200m(0.8mma)
NEW-5 to NEM 100m(0.65mma) 150m(0.8mma)
94
Accessories
Access control
*Available 2nd Quarter 2008
Features
Surface mount
AC-10S
Vandal resistant
access control keypad,
surface mount
l Two types of keypads are available.
AC-10S: Surface mount type AC-10F: Flush mount type
l AC-10S matches JK-DV and JF-DV, color video door stations.
l Vandal resistant panel, zinc die cast, and tamper proof screws are included.
l Two independent relay outputs (N/O or N/C) are available. When same access code is
programmed for both #1 and #2, two relays activate simultaneously.
l Programmable up to 100 access codes* 4, 5, or 6 digits in length.
* #1: up to 60, #2: up to 40
l Keypad lockout: After too many incorrect access codes are attempted.
l Anti-tailgate: As soon as the door is closed after access is granted on #1, the door is
locked even before programmed output time. Prevent sneak in.
l One push door release with external timer connection: While the external timer is on
operation, access code is not required. Press “0” key only. Programmable #1 and/or #2.
l External output for alarming: When “Lockout” or “Forced entry” occurs, external output
is available at #2.
l Two LED indicators show the status of the access control system.
l Illuminated keypad is easy to read.
l Audible key press
Features
l Activate door release (relay)
By keypad
By request to exit/entry button
Enter ID
Press button
Orange
#1
1
4
7
A
2
5
8
0
#1
3
6
9
B
1
4
7
A
#2
Green
#2
2
5
8
0
3
6
9
B
#1
#2
#2
Beep
JK-DV, AC-10S
m P.2
#1
ACCESSORIES
l Keypad lockout
Bleep
The keypad is locked
out after too many
incorrect access codes
are attempted.
1
4
7
A
Flush mount
2
5
8
0
3
6
9
B
Programmable
l Incorrect access code: 10-99 times
l Lockout time: 10-99 seconds
Blink keypad 4 times
Blink LED (orange) programmed period
Sound buzzer approx. 3 seconds
l Anti-tailgate
Door sense switch
Enter ID for #1
Lock
1 2 3
4 5 6
7 8 9
A 0 B
AC-10F
Vandal resistant
access control keypad,
flush mount
l One push door release with external timer connection
During the timer is on operation
ON: 9AM-5PM
Power source
12-24V DC power supply
12-24V AC transformer
★
95
Press “O” key
1
4
7
A
2
5
8
0
3
6
9
B
The design and specifications are subject to change without notice for improvement.
Unlock
Door is locked 1
second after door was
closed even during
relay on-time.
Wiring
(1) Relay #1 (Normally open)
(2) Relay #1 (Normally closed) & Relay #2 (Normally open)
300m /1.0mmø
#1 Electromagnetic
door strike
300m / 1.0mmø
M
MH2
#2 Electric
AC-10S
#1 Electric
door strike
2
MH2
2
AC-10S
2
12V-24V AC/DC
V
V
SW #1
PB1
PB2
C
T
Common
#1 Electric
door strike
NO1
C1
NC1
M
H
Request to exit
switch #1
NO2
C2
NC2
2
Power
source
V
V
SW #1
SW #2
Common
Timer
PB1
PB2
C
T
#1 Electromagnetic
door strike
Nomally closed
M
NO1
C1
NC1
2
12V-24V AC/DC
300m (18V - 24 AC/DC, 0.65 - 1.0mmø)
12V-24V AC/DC
Relay #1
N/O
2
door strike
300m (18V - 24 AC/DC, 0.65 - 1.0mmø)
Power
source
2
Relay #1
N/C
C
M
#2 Electric
door strike
NO1
C1
NC1
NO2
C2
NC2
12V-24V AC/DC
Request to exit
switch #1
Request to exit
switch #2
Timer
Relay #1
N/C
Relay #2
N/O
H
H : AC transformer
C : Power supply
Specifications (AC-10S, AC-10F)
25
33
29.5
117
5
Access code
Number: Up to 100 (#1: 60, #2: 40)
Code length: From 4, 5, or 6, (0 ~9, A, B)
Two conductors
Access control ~ Power source:
100m (12V – less than 18V AC/DC, 0.65 – 1.0 mmø)
300m (18V – 24V AC/DC, 0.65 – 1.0 mmø)
Access control ~ Request to exit button
300m (0.65 – 1.0 mmø)
45
Wiring
Wiring distance
Back Box
173
100
JK-DV + AC-10S
12 – 24V AC or 12 – 24V DC
Max. 100mA
Output: 2
Contact rating: 24V AC/DC,
3A (resistive load), 1A (inductive load)
Dry contact: Normally open or Normally closed
Operating time: From 1 second to 99 seconds
100
125
98
132
AC-10F
55
68.5
AC-10S
Power source
Consumption
Relay
45
Environment
Weather resistant (IP54 equivalent)
125
5
85
ACCESSORIES
Unit dimensions
98
33
96
Accessories
Call extension
Features
Wiring
l Announces (chime) call tone only, adjustable
l Indoor mounting
KC-1MRD
IER-2
Used for
2
IE series, MK-1GD, MK-2MCD
KC-1MRD, KC-1GRD, KB-3MRD
NEM-n, NEM-nA, TC-M
JA-2MECD, JA-2MCD, JF-1MD, JF-2MED,
JK-1MD, JK-1MED
NP
S
S
Unit dimensions
1
E
IER-2
83.5
120
Call extension
29
88
Door release
Features
Wiring
l Door release activation,
momentary or talk linecontrolled
KC-1MRD
LEF-10C
VC-M
–
L
L+
L–
Used for
EL-12S
Electric door
strike
ACCESSORIES
RY-PA
Door release relay
Single-family unit
DA-1DS/G, C-123L/A
IE-1AD(U), IE-1GD(U)
IE-2AD(U), IE-8MD(2)
TD-H/B (via DE-UR)
LEM-1DL
LEF, LEF-C (via RY-PA)
MK series
JA-2MECD, JA-2MCD
JF-1MD, JF-2MED
JK-1MD, JK-1MED
KC-1MRD, KC-1GRD
KB-3MRD
Multi-family unit
DA-2DS/G, DA-4DS/G
GF (5)
VC-M (via RY-PA)
EL-12S
EL-12S
YL
L+
L–
BK
RY-PA
H
H
BK : Black(2) YL : Yellow(2)
Specifications (EL-12S)
Power source & Consumption 12V AC, 125mA
12V DC, 200mA
Specifications (RY-PA)
Power source
Relay contact rating
12V DC
110V AC, 1A
24V DC, 1A
Relay
Features
Wiring
Intercom station can be signaled by external
device via RY-AC/A relay. External device will
be activated momentarily as long as the call
signal on the intercom is activated.
Used for
TD-H/B, TD-Z/A
IE-Series
IE-8MD, LEF
(1)
(2)
PWR
1
E
1
E
–
+
–
T
WH
YL
RD RY-AC/A
BK
YL
RY-AC/A
(1) External signaling device, bell, etc. (2) Call receive
termimal WH : White RD : Red(+) BK : Black(-) YL : Yellow
PWR : Power source
External signaling relay
Specifications (RY-AC/A)
Unit dimensions
Power source
62
104
97
LEF-10
LE-D
41
Contact rating
12V DC, supplied by power supply of
system or trunk line.
0.3A, 240V AC 1.0A, 24V DC
Bell, buzzer, etc. must be AC
operated or DC mechanical type only.
Relay
Features
Wiring
Allows integration of a
doorbell, etc. to intercom. The
device will be activated as long
as handset is ringing. When
the intercom is picked up, the
device will no longer be
activated.
MK-DH
(1)
NP
A1
A2
Used for
IE chime tone
IE-8MD
MK-1GD
MK-2MCD
KC, KB series
AT-406
TB-SE(TC-M)
TAR-3
MK-1GD
PWR
A1
A2
WH
BL
BK
S
S
A
+
–
U
TAR-3
(–)
(+)
OG
OG
RD
W
(1) Bell, etc. PWR : Power source
WH : White BL : Blue BK : Black(-) RD : Red(+) OG : Orange
W : PS-0602D, PS-0602C
Unit dimensions
62
External signaling relay
Specifications (TAR-3)
41
104
Power source
Contact rating
6V DC, supplied by PS-0602D, PS-0602C
0.3A, 240V AC
1.0A, 24V DC
Doorbell or buzzer must be AC operated
or DC mechanical type only.
Auxiliary light power control
Features
Wiring
KB-3MRD
(1)
(2)
MAW-B
WH
bn
E
BL
Used for
RD
KB-3MRD, GF-BC(GF)
OG
PWR
BK
ACCESSORIES
MAW-B relay is used for
turning on an auxiliary light to
spotlight a caller at the
entrance.
The light is illuminated when
the residential call button is
pressed, and during visual
monitoring mode.
N
+
–
bn = b1~b3
Unit dimensions
(1) Porch light, etc. (2) Local switch
WH : White BL : Blue RD : Red(+) BK : Black(-) OG : Orange(2)
MAW-B
Auxiliary light control relay
62
Specifications (MAW-B)
104
41
Power source
Power supply
Power consumption
Relay contact rating
24V DC
PS-2420S, PS-2420UL, PS-2420 of system.
2.5W max. 0.5W standby
Dry closure contact for incandescent light for
general lighting of less than 100W.
98
Power Supplies
15V AC
Unit dimensions
PT-1211D
58
Specifications (PT-1211D)
46
Input voltage & Capacity
230V AC, 50/60Hz
Output voltage
15V AC
83
*Manufactured by Sino-American
PT-1211D
Specifications (PT-1211C)
48
77
PT-1211C
60
Input voltage & Capacity
120V AC, 50/60Hz
Output voltage
15V AC
*Manufactured by Sino-American
Used for
PT-1211C
DA-1MD
6V DC
Unit dimensions
Specifications (PS-0602C)
Input voltage & Capacity
120V AC, 50/60Hz
Output voltage
6V DC, 0.2A
75
PS-0602D, PS-0602C
Specifications (PS-0602D)
39.5
Used for
230V AC, 50/60Hz.
Output voltage
6V DC, 0.2A
*Manufactured by Sino-American
12V DC
Unit dimensions
PS-1225S, PS-1225UL
52
90
PS-1225S
PS-1225UL
PS-1225
(without AC cord)
99
Input voltage & Capacity
C-123L/A, AT-406, LEM,
TAR-3
167
POWER SUPPLIES
PS-0602D
PS-0602C
51
Used for
IE-1AD(U), IE-1GD(U), IE-2AD(U),
IE-2A2DU, IE-8MD, LEM-1DL,
LEF, LEF-C, TD-H/B,
TD-Z/A, VC-M, MP-S,
NEW-5 (NEM), TB-AD10 (TC-M)
Specifications (PS-1225S, PS-1225UL, PS-1225)
Input voltage & Capacity
100-240V AC, 50/60Hz 37W/6582VA
Output voltage
12V DC, 2.5A
18V DC
Unit dimensions
Used for
IE-8MD, JBW-BA, JF-1MD, JF-2MED, JK-1MD, JK-1MED
MK-1GD, MK-2MCD, TC-M, MYW-BA, KC-32EU, RY-3DL
PS-1820S
52
90
167
Specifications (PS-1820S, PS-1820UL, PS-1820)
Input voltage & Capacity
100V-240V AC, 50/60Hz, 45W/75-95VA
Output voltage
18V DC, 2A
PS-1820S
PS-1820UL
PS-1820
(without AC cord)
24V DC
Unit dimensions
Used for
JA-2MECD, JA-2MCD, GF-BC, GF-VBC/A, GFW-VBC, MAW-B
MYW-BA, YAZ-90-3W, NEM-(A)/C, KC-1MRD, KC-1GRD
KB-3MRD, KC-32EU, RY-3DL, MU-100
PS-2410LD
164
Specifications (PS-2410LD)
Input voltage & Capacity
220-240V AC, 50/60Hz 35W
Output voltage
24V DC, 1A
RD BK
(+) (–)
PS-2410LD
PS-2410LC
Specifications (PS-2410LC)
Input voltage & Capacity
120V AC, 50/60Hz 35W
Output voltage
24V DC, 1A
PS-2420S, PS-2420UL
52
90
167
Specifications (PS-2420S, PS-2420UL, PS-2420)
PS-2420S
PS-2420UL
PS-2420
Input voltage & Capacity
100-240V AC, 50/60Hz 60W/100-125VA
Output voltage
24V DC, 2A
POWER SUPPLIES
66
95
RD : Red (+). BK : Black (-).
(without AC cord)
100
Communication Distance
The below graph is to assist you in determining the diameter of wires or communication distance required.
Example;
To obtain the communication distance for IE-1AD(U) system using 0.8 mm dia. wires;
1. On the graph;
Draw a line from IE-1AD(U) on point A 7.8, crossing the line B
at the point 0.8 to reach a point reading 225.
A
Distance
B
IE-1AD(U)
0.8
28
225 (m)
COMMUNICATION DISTANCE CALCULATION GRAPH
SYSTEM & MODELS
TB-AD1, AD10 [TC-M]
C-123L/A
IE-1GD(U) [IEH-1CD]
IE-2AD(U) [IEH-1CD]
IE-2A2DU [IEH-1C2D]
A
COMMUNICATION
DISTANCE
...m
FIXED NUMBER
FOR DISTANCE
BY ITEM
2,000
MP-1S, MP-3S
3.4
NEM-nA/C, NEM-n/C
3.9
5.2
COMMUNICATION DISTANCE
TCS-MH
IE-1AD(U) [IF-DA]
IE-1GD(U) [IF-DA]
IE-2AD(U) [IF-DA], IE-2A2DU
DE-UR [IF-DA]
AP-1M/A, AP-5M/A, AP-10M/A
6.8
7.8
10.4
B
DIAMETER
mm
1.6
900
800
1.4
700
1.2
600
1.0
LEM-1, LEM-3
LEF-3, LEF-5 , LEF-10
LEF-10S
LEF-3C, LEF-5C, LEF-10C
1,000
500
0.8
400
17.4
0.65
20.9
26.2
300
0.5
225
200
VC-nM, VCH [VC-K]
34.0
36.7
AT-206 [AT-306x3]
TC-M [TB-SE]
100
MC-60/4A
90
TD-1H, TD-3H, TD-6H
TD-12H, TD-24H
TD-6Z, TD-12Z
80
AT-406
50
70
60
40
30
20
NOTES;
IE-1AD(U) [IF-DA] shows distance between IE-1AD(U) and IF-DA or other IE door station.
Video Intercoms are not included in the graph.
101
Compatibility of video intercom system
Hands-free color video intercom
✓: Compatible Blank: Not Compatible
Existing model
Door station
Sub station
Video door station
Audio door station
Discontinued model
Sub master station
Sub station
Long distance Video door Sub master
adaptor
station station
JA-DAC JF-DA JK-DA AX-DV JA-D JF-D AX-DM JA-2HCD JA-2SD JF-2HD JF-2SD JK-1HD JK-1SD JF-1FD JF-1SD JBW-BA JKW-BA JB-DA JB-2HD
JA-DGC JF-DV JK-DV AX-DV-P
(audio)
(audio)
(audio)
JB-DV
(audio)
JF-DVF JK-DVF AX-DVF
JB-DVF
AX-DVF-P
Master
station
JA-2MECD ✓
✓
JA-2MCD
JF-1MD
✓
Existing JF-2MED
✓
model
✓
JK-1MD
✓
JK-1MED
✓
AX-8MV
✓
Discon. JB-2MED
model JB-2MD
✓
AX-8MV requires a central exchange unit.
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Color video intercom ✓: Compatible Blank: Not Compatible
Door station
Sub station
Adaptor
Existing model
Sub master station
Video door station
KB-DAR
KC-DAR
KB-3HRD
KB-3SD
(audio)
✓
✓
Master
station
KB-3MRD
Existing KC-1MRD
model
KC-1GRD
Discon. KA-1MD
model KA-1MRD
✓
Discontinued model
Long distance Picture
adaptor
memory
✓
✓
KC-1HRD
KC-1SD
(audio)
✓
✓
JBW-BA
KC-32EU
✓
✓
✓
✓
✓
Video door station
Sub station
KA-DA
MK-1SD/B
(audio)
KA-DAR
✓
✓
✓
✓
Discontinued model
Long
Door station
Picture
Audio door
Video door station
Sub master station memory distance
Video door station
station
adaptor
Sub station
Adaptor MK-DV MK-DH MK-DAC MK-2DA MK-D MK-1HD MK-2SD MK-2HCD KC-32EU MYW-BA MY-DA MY-DC, /A MY-DS MK-DA MK-DS MK-DS/B
MK-DVF
Master
station
✓
✓
Existing MK-1GD
✓
model MK-2MCD
MY-1CD
Discon. MY-2CD
model MK-1MD
MK-1MD/A
*Pan tilt feature does not work.
MK-DGC MK-2DG
MK-DBC
(audio)
✓
✓
✓
✓
✓*
✓*
✓
✓
✓
✓
MY-DB MY-DG, /A
MY-CB MY-CA
MY-EA
MY-FA
✓
✓
✓
✓
✓
✓
✓
✓
B & W separate monitor and Door adaptor
✓
✓
✓
✓
✓
✓
✓*
✓*
✓
✓
MY-CU
Existing MYW-P1L
model
MYW-P3L
MY-U
Discon.
model MYW-P3B
MYW-P3CB
✓
✓
✓
✓*
✓*
✓
*Pan tilt feature does not work.
Video door station
MK-DAC
MK-DGC
MK-DBC
✓
✓
✓
✓*
✓
✓
✓*
✓*
✓
✓
✓*
✓*
✓
✓
✓*
✓*
✓
✓
✓
✓
✓: Compatible Blank: Not Compatible
Discontinued model
Existing model
Door station Sub monitor
Sub station
Adaptor MYH-CU
MYH-CUB
Monitor
Door adaptor
✓
✓
✓*
✓*
MK-DS/A
MK-DV
MK-DVF
Long distance
adaptor
Sub monitor
MYW-BA
MYH-U
✓
✓
✓
✓
Compatibility of video intercom system
✓: Compatible Blank: Not Compatible
Existing model
B & W video intercom
Video door station
MY-DA
MY-DB
MY-CB
✓*
✓*
✓
✓
✓
✓
✓
✓
MY-DC, /A
MY-DG, /A
MY-CA
MY-EA
MY-FA
✓
✓
✓
✓*
✓*
✓
MY-DS
✓*
✓*
✓*
✓
✓
✓
MK-DS/B
✓*
✓
✓
✓
102
INDEX
PAGE
A
AC-10F ............................................... 95
AC-10S ...............................................95
AI-900AF ............................................74
AI-900AL ............................................74
AI-900CO............................................74
AI-900DI .............................................74
AI-900MF............................................74
AI-900MS ...........................................74
AI-900RS ............................................74
AI-900TI ............................................. 74
AI-910DI............................................. 74
AI-MS900 ........................................... 73
AI-PN100B..........................................74
AI-PU200 ........................................... 74
AI-RS150 ........................................... 73
AI-RS160 ........................................... 73
AI-RS170 ........................................... 73
AI-RS180 ...........................................73
AI-YC303 ............................................74
AP-10M .............................................. 84
AP-1M ................................................ 84
AP-5M................................................. 84
AS-3A ................................................ 83
AS-3N ................................................ 83
AT-306 ............................................... 63
AT-406 ...............................................63
AT-406B/A ..........................................63
AT-406P.............................................. 63
AX-084C ........................................ 17,67
AX-16SW....................................... 18,67
AX-248C ........................................ 17,67
AX-320C ........................................ 17,67
AX-8M ........................................... 18,67
AX-8MV ......................................... 18,67
AX-DM .....................................17,26,68
AX-DV............................................ 17,68
AX-DVF.......................................... 17,68
AX-DVF-P....................................... 17,68
AX-DV-P......................................... 17,68
PAGE
B
BG-10C............................................... 62
PAGE
C
C-123L/A ............................................ 24
C-D ..................................................... 24
C-ML/A .............................................. 24
INDEX
D
PAGE
DA-1AG .............................................. 23
DA-1AS .............................................. 23
DA-1MD ........................................ 23,54
DA-2DG .............................................. 54
DA-2DS ............................................. 54
DA-4DG ..............................................
......................................... 54
DA-4DS .............................................. 54
DAR-1 ........................................... 23,54
DAW-P........................................... 23,54
DE-UR ................................................ 65
PAGE
E
EL-12S ............................................... 97
PAGE
G
GF-10K .......................................... 35,49
GF-10KP......................................... 35,49
GF-1D ................................................. 51
GF-1DK............................................... 51
GF-1MD.............................................. 51
103
GF-1MD-SW ....................................... 51
GF-1MDK............................................ 51
GF-1P ............................................35,49
GF-2B ............................................35,50
GF-2F ............................................35,50
GF-2P ............................................35,49
GF-3B ............................................35,50
GF-3F ............................................35,50
GF-3P ............................................35,49
GF-4P ............................................35,49
GF-4Z ................................................. 52
GF-AD ................................................. 49
GF-AP ............................................35,49
GF-BC ................................................. 52
GF-BP ............................................35,49
GF-DA ................................................ 49
GF-DP ................................................. 49
GF-MK ................................................ 51
GF-nBA (n=102, 202, 103, 203) ............... 36,50
GF-nH (n=102, 202, 103, 203, 303) ........... 36,50
GF-nHB (n=102, 202, 103, 203, 303) ......... 36,50
GF-NS ................................................ 49
GF-NSP.......................................... 35,49
GF-SW ................................................ 49
GF-VA ................................................. 49
GF-VBC ............................................... 52
GF-VP............................................. 35,49
GFW-LD.............................................. 53
GFW-S ........................................... 39,51
GFW-VBC ........................................... 53
GH-10K .............................................. 35
GH-1AD .............................................. 38
GH-1KD .............................................. 38
GH-1KDS ............................................ 38
GH-1MD ............................................. 38
GH-4Z................................................. 39
GH-AD ................................................ 35
GH-BC ................................................ 39
GH-BCX ............................................. 40
*1 GH-CCTV ............................................ 42
GH-DA ................................................ 35
GH-DP ................................................ 35
GH-HS ................................................ 38
GH-MK ............................................... 39
GH-NS ................................................ 35
GH-RY ................................................ 40
GH-SW ............................................... 35
GH-VA ................................................ 35
GH-VBC .............................................. 39
GH-VBX .............................................. 40
GHW-LC ............................................. 41
PAGE
I
IAI-100 ............................................... 76
IAX-100 .............................................. 76
IE-1AD(U)........................................... 26
IE-1GD(U) .......................................... 27
IE-2A2DU ........................................... 28
IE-2AD(U)........................................... 28
IE-8HD................................................ 29
IE-8MD ............................................... 29
IE-DC .................................................. 30
IE-DL1 ................................................ 30
IE-DL2................................................ 30
IE-DL3 ................................................ 30
IE-FY ................................................. 30
IEH-1C2D ........................................... 28
IEH-1CD ........................................ 27,28
IE-JA .................................................. 30
IER-2 .................................................. 97
IF-DA .................................................30
IME-100 .............................................75
IME-150 .............................................76
IMU-100 .............................................75
ISE-100 ..............................................76
PAGE
J
JA-2HCD .............................................10
JA-2MCD ..............................................9
JA-2MECD ............................................9
JA-2SD ...............................................10
JA-D .....................................................9
JA-DAC .................................................9
JA-DGC ................................................9
JBW-BA ..............................................21
JBW-D .............................................. 4,6
JDW-C ..................................................9
JF-1FD ..................................................6
JF-1MD ................................................5
JF-1SD .................................................6
JF-2HD .................................................8
JF-2MED .............................................. 7
JF-2SD ................................................. 8
JF-D...................................................... 7
JF-DA ............................................... 5,7
JF-DV ............................................... 5,7
JF-DVF ............................................. 5,7
JFS-1AD ............................................... 6
JFS-1ADF ............................................. 6
JFS-1ADV ............................................. 6
JFS-2AED ............................................ 8
JFS-2AEDF ........................................... 8
JFS-2AEDV .......................................... 8
K
PAGE
KA-DGR PANEL ...................................12
KAW-D................................................ 22
KB-3HRD ............................................16
KB-3MRD ............................................15
KB-3SD ...............................................16
KB-DAR ..............................................15
KC-1GRD ............................................13
KC-1HRD ........................................... 14
KC-1MRD ........................................... 11
*1 KC-1SD .............................................. 14
KC-32EU............................................. 21
KC-DAR ........................................ 11,13
KCS-1ARD .......................................... 12
L
*2
*2
*2
*2
PAGE
LE-A ......................................... 58,60,62
LE-A3 ............................................ 58,62
LE-AN ....................................... 58,60,62
LE-AN3 .......................................... 60,62
LE-B .............................................. 61,62
LE-BN ............................................ 61,62
LE-C .............................................. 61,62
LE-CN ........................................... 61,68
LE-D ............................... 57,58,60,61,62
LE-DA ............................. 57,58,60,61,62
LE-DL ................................................. 62
LEF-10 ................................................ 59
LEF-10C ............................................. 61
LEF-10S ............................................. 59
LEF-10W ............................................ 59
LEF-1C .......................................... 61,62
LEF-20(S) ........................................... 60
LEF-3 ................................................. 59
LEF-30(S) ........................................... 60
LEF-3C ............................................... 61
*2 LEF-40(S) ....................................60
LEF-5 ...........................................59
LEF-5C .........................................61
LEF-5W ........................................59
LEM-1 ..........................................58
LEM-1DL .....................................57
LEM-3 ..........................................58
LEW-10 ........................................60
LEW-10S .....................................60
LEW-5 .........................................60
M
PAGE
MAW-B ........................................98
MC-60/4A ....................................82
*2 MC-60/4B ....................................82
MC-A/A ........................................82
MCW-S ........................................22
MK-1GD .......................................19
MK-1HD .......................................19
MK-2DA .......................................22
MK-2DG .......................................22
MK-2DG PANEL ...........................22
MK-2HCD ....................................18
MK-2MCD ....................................18
MK-2SD ..................................19,20
*1 MK-D ...........................................20
MK-DAC ......................................20
MK-DBC ......................................20
MK-DGC ......................................20
MK-DH....................................19,20
MK-DV .........................................19
MK-DVF .......................................19
MKS-1GD ....................................19
MKS-1GDV ..................................19
MKS-1GDVF ................................ 19
MKW-P ........................................19
MKW-R ........................................20
MP-1S .........................................83
MP-3S .........................................83
MYW-BA .....................................22
P
PAGE
PD-1................................................... 66
PD-2................................................... 66
PS-0602C........................................... 99
PS-0602D .......................................... 99
PS-1225 ............................................ 99
PS-1225S ......................................... 99
PS-1225UL ....................................... 99
PS-1820 ...........................................100
PS-1820S .........................................100
PS-1820UL .......................................100
PS-2410LC .......................................100
PS-2410LD .......................................100
PS-2420............................................100
PS-2420S .........................................100
PS-2420UL .......................................100
PT-1211C .......................................... 99
PT-1211D .......................................... 99
R
PAGE
RY-3DL .............................................. 21
RY-AC/A ........................................... 97
RY-PA ............................................... 97
TC-40GS ............................................80
TC-DC .................................................25
TC-MH ................................................25
TCS-MH .............................................25
TD-12H/B ........................................... 66
TD-12Z/A ........................................... 66
TD-1H/B .............................................65
TD-24H/B ........................................... 66
TD-3H/B ............................................. 65
TD-6H/B ............................................. 65
TD-6Z/A ............................................. 66
TDW-1/A ............................................ 66
TDW-12/A .......................................... 66
TDW-24/A .......................................... 66
TDW-3/A ............................................ 66
TDW-6/A ............................................66
V
PAGE
VC-0M ................................................ 55
VC-10M .............................................. 55
VC-1M ................................................ 55
VC-26MT ............................................ 56
VC-26MY ............................................ 56
VC-2M ................................................ 55
VC-42MY ............................................ 56
VC-4M ................................................ 55
VC-58MT ............................................ 56
VC-6M ................................................ 55
VC-8M ................................................ 55
VC-BBX .............................................. 56
VCH-16 .............................................. 55
VCH-8 ................................................ 55
VC-K .................................................. 55
W
PAGE
W-DIN11 ....................................... 40,53
Y
PAGE
YAW-RB ............................................. 64
YAZ-90-3W......................................... 65
*1 Not available in Europe
*2 Not available in Europe, Australia,
nor New Zealand
INDEX
PAGE
N
NA-A .......................................77,91
NA-AN.....................................77,91
NA-NE .....................................77,92
NAR-2A .......................................92
NAR-3 ..........................................92
NAR-6A ..................................78,92
*2 NA-T/A ...................................78,92
*1 NBJ-20 ........................................94
*1 NBJ-20B ......................................94
*1 NBJ-40 ........................................94
*1 NBJ-40B .................................... 94
NB-L ...................................... 77,92
NBR-7AS ............................... 78,92
*2 NBR-7AS-S ..................................92
NBR-8A .......................................92
NB-U ............................................94
NBY-1A ........................................92
NBY-4A ........................................92
*1 NBZ-M .........................................83
N-EA ............................................83
NE-JA .................................... 78,92
NEM-10/C .............................. 77,91
NEM-100................................ 78,93
NEM-100A ............................. 78,93
NEM-10A/C ............................ 77,91
NEM-110 ............................... 78,93
NEM-110A ............................. 78,93
NEM-120 ............................... 78,93
NEM-120A .................................... 78,93
NEM-20/C ..................................... 77,91
NEM-20A/C ................................... 77,91
NEM-30/C...................................... 77,91
NEM-30A/C ................................... 77,91
NEM-40/C...................................... 77,91
NEM-40A/C ................................... 77,91
NEM-50 ......................................... 78,93
NEM-50A .......................................78,93
NEM-60 .........................................78,93
NEM-60A .......................................78,93
NEM-70 .........................................78,93
NEM-70A .......................................78,93
NEM-80 .........................................78,93
NEM-80A ......................................78,93
NEM-90 .........................................78,93
NEM-90A ......................................78,93
NEW-5................................................ 94
NH-1SA/A .......................................... 88
NH-2SA/A .......................................... 88
NHR-30K ........................................... 87
NHR-3A-4 .......................................... 88
NHR-3TS ........................................... 88
NHR-4A/A .......................................... 88
NHR-7A ............................................. 88
NHR-8A ............................................. 88
NHR-DP ............................................. 88
NHR-SP ............................................. 87
NHX-30G ........................................... 87
NHX-50M ........................................... 87
NHX-80X ........................................... 87
NP-B .................................................. 83
NP-W ................................................. 83
*2 NR-4AS13 ......................................... 92
T
PAGE
TAR-3 .................................................98
TB-AD1 .............................................. 81
TB-AD10 .............................................81
*1 TB-ADD ..............................................81
TB-SE .................................................80
TC-10M .........................................80,81
*1 TC-10MD ............................................81
TC-20G ...............................................80
TC-20M ..............................................80
TC-40G ...............................................80
104
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement