emc test report
Test Report issued under the responsibility of:
EMC TEST REPORT
EN 301 489-7 V1.3.1:2005-11
Electromagnetic Compatibility for radio equipment and services –
mobile and portable radio and ancillary equipment
Report Reference No. .....................:
G0M-1103-1036 – E-13
Testing Laboratory .........................:
Eurofins Product Service GmbH
Address.............................................:
Storkower Str. 38c
15526 Reichenwalde
Germany
Accreditation .....................................:
DAkkS - Registration number : D-PL-12092-01-01
Applicant’s name ............................:
Falcom Wireless Communications GmbH
Address.............................................:
Gewerbering 6
98704 Langewiesen
Germany
Test specification:
Standard ...........................................:
EN 301 489-7 V1.3.1:2005-11
EN 301 489-1 V1.8.1:2008-04
Non-standard test method…………..:
N/A
Equipment under test (EUT):
Product description. ..........................:
Asset tracker
Model No. .........................................:
Rock
Hardware Version .............................:
Rev.02b
Software / Firmware Version ............:
10.00.003
Test result
Passed
Test Report No.: G0M-1103-1036–E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 1 of 13
REPORT INDEX
1 EQUIPMENT (TEST ITEM) DESCRIPTION
4 1.1 Equipment photos
5 1.2 Supporting Equipment Used During Testing
6 1.3 Input/Output Ports
6 1.4 EUT Operation Modes
6 1.5 Immunity Performance Criteria
7 2 RESULT SUMMARY
8 3 TEST CONDITIONS AND RESULTS
9 3.1 Test Conditions and Results – Immunity to RF electromagnetic fields
9 3.2 Test Conditions and Results – Electrostatic discharge (ESD)
11 Test Report No.: G0M-1103-1036-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 3 of 13
1
Equipment (Test item) Description
Description
Asset tracker
Model
Rock
Serial number
unspecified
Hardware version
Rev.02b
Software version
10.00.003
Manufacturer
FMO Electronics GmbH
Ratings / Power supply
7.5 VDC (battery pack)
Number of tested samples
1
Device classification
Class B
Equipment type
mobile use
Test Report No.: G0M-1103-1036-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 4 of 13
1.1
Equipment photos
EUT, TOP
EUT, BOTTOM
Test Report No.: G0M-1103-1036-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 5 of 13
1.2
Supporting Equipment Used During Testing
Product
Type*
Device
Manufacturer
Model No.
SIM
radio communication
tester
Rohde & Schwarz
CMU200
Comments
*Note: Use the following abbreviations:
AE : Auxiliary/Associated Equipment, or
SIM : Simulator (Not Subjected to Test)
CABL : Connecting cables
1.3
Input/Output Ports
The EUT has no input or output ports.
1.4
Mode #
1
EUT Operation Modes
Description
EUT, connected via GSM900 PCL 5 to radio communication tester.
Test Report No.: G0M-1103-1036-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 6 of 13
1.5
Immunity Performance Criteria
The test results shall be classified in terms of the loss of function or degradation of performance of the
equipment under test, relative to a performance level defined by its manufacturer or the requestor of
the test, or agreed between the manufacturer and the purchaser of the product.
Definition related to the performance level:
based on the used product standard
based on the declaration of the manufacturer, requestor or purchaser
Criterion A:
Definition: During testing, normal performance within the specified limit:
Representative parameter
Acceptable level of performance
Communication link quality and
maintenance
the RXQUAL of the downlink shall not exceed the value of three during
test, no unintentional transmissions in standby
Criterion B:
Definition: During testing, temporary degradation, or loss of function or performance which is selfrecovering:
Representative parameter
Acceptable level of performance
Communication link quality and
maintenance
GSM communication link shall be maintained during test, no
unintentional transmissions in standby
Criterion C:
Definition: During testing, temporary degradation, or loss of function or performance which requires
operator intervention or system reset occurs:
Representative parameter
Acceptable level of performance
Communication link quality and
maintenance
GSM communication link not maintained during test, communication
link shall be recoverable by operator, no unintentional transmissions in
standby.
Test Report No.: G0M-1103-1036-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 7 of 13
2
Result Summary
EN 301 489-7, EN 301 489-1
Product
Specific
Standard
Reference
Method
Result
Remarks
EN 55016-2-3:2006
PASS
Tested according relevant
radio product standard.
See G0M-1103-1036-T-51
EN 55022:2006
N/A
EUT battery powered
EN 301 489-7
Harmonic current emissions
Clause 7.1
EN 61000-3-2:2006
N/A
EUT battery powered
EN 301 489-7
Voltage fluctuations / Flicker
Clause 7.1
EN 61000-3-3:1995
N/A
EUT battery powered
EN 301 489-7 Radiated RF immunity in the frequency range
Clause 7.2
80MHz to 2.7GHz
EN 61000-4-3:2006
PASS
EN 301 489-7 Conducted RF immunity in the frequency range
Clause 7.2
0.15MHz to 80MHz
EN 61000-4-6:2005
N/A
EUT battery powered
ISO 7637-2:2004
N/A
EUT battery powered
EN 301 489-7
Electrostatic Discharge (ESD)
Clause 7.2
EN 61000-4-2:2001
PASS
EN 301 489-7
Fast Transients, common mode
Clause 7.2
EN 61000-4-4:2004
N/A
EUT battery powered
EN 301 489-7
Surges
Clause 7.2
EN 61000-4-5:2006
N/A
EUT battery powered
EN 301 489-7
Voltage dips and interruptions
Clause 7.2
EN 61000-4-11:2004
N/A
EUT battery powered
Requirement – Test
EN 301 489-7 Radiated EMC emissions in the frequency range
Clause 7.1
30 MHz to 6000 MHz
EN 301 489-7 Conducted EMC emissions in the frequency range
Clause 7.1
150kHz to 30 MHz
EN 301 489-7 Transients and surges in the vehicular
Clause 7.2
environment
Remarks:
Comment regarding test case specific product standard selection:
All product specific standards are stated in the headline of the table. If a product dependent part
overrides the test specific parameters of a common part, the product dependent part and sub-clause
of the test is stated in the table as product standard. If more than one product standard defines the
same test case with the same reference method but with different test levels or limits only the most
stringent product standard is stated in the table. If different product standards define the same test
case but refer to different reference test methods or standards, the test case is shown for each
product standard.
Test Report No.: G0M-1103-1036-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 8 of 13
3
Test Conditions and Results
3.1
Test Conditions and Results – Immunity to RF electromagnetic fields
Immunity to RF electromagnetic fields acc. to EN 301 489-7
Verdict: PASS
Laboratory Parameters:
Required prior to the test
During the test
Ambient Temperature
15 to 35°C
23°C
Relative Humidity
30 to 60%
41%
Test according to referenced
standards
Common Part
Reference Method
EN 301 489-1
EN 61000-4-3
Frequency range
Fully configured sample scanned
over the following frequency range
80MHz to 2.7GHz
Samples tested on the following
number of orientations
Number of orientations
EUT operating mode
1
80 – 1000
Test level
[V/m]
3
1400 – 2700
3
Frequency [MHz]
4
Test parameters and results
Frequency
Modulation
step
80% AM 1kHz
1%
80% AM 1kHz
Dwell time
Result
Criterion
2s
PASS
A
2s
PASS
A
1%
Comments:
Test Equipment Used
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
Generator
R&S
SME06
Amplifier
Amplifier
Research
Inv. No. 0100
Oct 09
Oct 11
100W1000M1
Inv. No. 0237
System
calibration
Amplifier
Amplifier
Research
60S1G3
Inv. No. 0448
System
calibration
Antenna
Frankonia
BTA-H
Inv. No. 0472
System
calibration
Horn antenna
Schwarzbeck
BBHA 9120C
Inv. No. 0019
Aug 06
Aug 11
Millivoltmeter
R&S
URV55
Inv. No. 0348
Apr 10
Apr 11
Directional Coupler
MEB
RK100
Inv. No. 0372
System
calibration
Directional Coupler
Narda
3002-20
Inv. No. 0145
System
calibration
EMI Receiver
R&S
ESCS30
Inv. No. 0476
Jun 10
Jun 11
Test Report No.: G0M-1103-1036-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 9 of 13
Measurement uncertainties
Frequency range [MHz]
Expanded
uncertainty [dB]
80 – 3000
2.7
Test setup
Test Report No.: G0M-1103-1036-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 10 of 13
3.2
Test Conditions and Results – Electrostatic discharge (ESD)
Electrostatic discharge acc. to EN 301 489-7
Verdict: PASS
Laboratory Parameters:
Required prior to the test
During the test
Ambient Temperature
15 to 35°C
23°C
Relative Humidity
30 to 60%
41%
Air pressure
860mbar to 1060mbar
1117mbar
Test according to referenced
standards
Common Part
Reference Method
EN 301 489-1
EN 61000-4-2
Discharge location
See photo documentation of the test set-up and tabulated results
All external locations accessible by hand, Horizontal plate (HCP)
Vertical coupling plate (VCP)
EUT operating mode
1
Test parameters and results
Number of discharges per
Discharge level [kV]
location (each polarity)
Positive
Negative
Discharge type
Result
Criterion
Contact – direct
2/4
2/4
10
PASS
A
Contact – indirect
2/4
2/4
10
PASS
A
Air -direct
2/4/8
2/4/8
10
PASS
A
Comments:
Test Equipment Used
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
ESD gun
Schlöder
SESD 30000
Inv. No. 0001
Jan 09
Jan 11
Test Report No.: G0M-1103-1036-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 11 of 13
Test setup: contact discharge
Test setup: air discharge
Test setup: indirect discharge
Test Report No.: G0M-1103-1036-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 12 of 13
EUT: discharge locations
→
Contact discharge
→
Air discharge
Test Report No.: G0M-1103-1036-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 13 of 13
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement