www.time
Welcome to the Time Electronics USA and Canada Catalogue
2009 marked Time Electronics’ 42nd year of business. During this time we have delivered
accuracy and precision in the field of calibration to engineers worldwide. We are proud to be
one of the leading international manufacturers of calibrators and test equipment. With
experience and expertise we help our customers meet the objectives of their competitive
industries.
Using Acrobat Reader you can navigate through our extensive range of products.
Open the Bookmarks panel on the left hand side to view product categories.
Follow the instructions below for simple navigation:
‘Click’ to print
‘Click’ to open
bookmarks panel
‘Click’ to
expand section
‘Click’ to view
page
Time Electronics USA, 55 Lumber Rd, Roslyn, NY 11576, USA
Tel: 516 723 9909 Fax: 516 723 9910 E-mail: [email protected]
www.timeeusa.com
2
Contents
Portable Test Instruments
3 – 36
Simulators, Sources, Potentiometers, Calibrators
Decade Boxes
37 – 52
Resistance, Capacitance, Inductance
Digital Multimeters and Power Calibrators
53 – 65
Precision DMMs , AC/DC Power Source/Calibration
Multifunction Calibrators
67 – 80
Universal Calibration Systems for Multi Product Calibration
Calibration Software
81 – 88
EasyCal: Automate the Calibration Process
Process Control Equipment
89 – 118
Pressure, Temperature, Loop – Portable and Benchtop
Calibration Benches
119 – 143
Comprehensive Modular Test Benches and Laboratory Design
Product Index
www.timeeusa.com
2
144
Tel: 516-723-9909
CONTENTS
Email: [email protected]
3
Portable Test Instruments
Time Electronics design a complete line of Portable Test Equipment, built for a wide
range of capabilities across various industries. These well-proven test instruments
cover the requirements of both field and laboratory work. They are high performance,
delivering precision, reliability, and ease of use for all test applications.
VOLTAGE
1006 Handheld DC Millivolt Source - 0.02% Accuracy ......................................................................... 4
1007 Handheld DC Millivolt Potentiometer & Source (0.02% Accuracy) .............................................. 6
1010 Transportable DC Voltage Calibrator (0.02% Accuracy) .............................................................. 8
CURRENT
1021 Handheld DC Current Source With Null Meter (0.02% Accuracy) ............................................. 10
1024 Transportable DC Current Calibrator with Null Measuring (0.02% Accuracy) ............................ 12
MULTIFUNCTION V-I-R and PROCESS CALIBRATORS
1017 Transportable DC Multifunction VIR Calibrator (0.005% Accuracy) ........................................... 14
1030 Microcal - Handheld Voltage & Current Source ......................................................................... 16
1044 Handheld DC Voltage and Current Calibrator (0.05% Accuracy)............................................... 18
1048 Handheld V-I Loop Calibrator (0.02% Accuracy) ....................................................................... 20
1049 Handheld PT100 Simulator Handheld (Class A °C) ................................................................... 22
1050 Handheld PT100 Simulator Handheld (Class A °F) ................................................................... 23
1077 Handheld Milliamp Transducer/Line Simulator (Transim) .......................................................... 24
1090 Handheld Temperature and Process Calibrator ......................................................................... 26
7000 Handheld RTD Temperature Calibrator ..................................................................................... 28
7005 Handheld Loop Calibrator .......................................................................................................... 30
7006/7007 Loop-Mates 1 and 2 (Handheld Simulator & Indicator) ..................................................... 32
ELECTRICAL TEST (Transportable)
5068 Inscal - Insulation Tester Calibrator (100kΩ - 10GΩ) ................................................................. 33
5069 Inscal - Insulation Tester Calibrator (100kΩ - 100GΩ) ............................................................... 34
5070 DuctorCal - Calibrator for Ductor Testers and Micro-Ohm Meters ............................................. 35
5080 Pat Cal 2 - Calibrator for PAT's and Insulation Testers .............................................................. 36
Also see:
Decade Boxes for portable Resistance Measurement/RTD/PRT.
Process Control Equipment for transportable Pressure/Temperature/Loop Calibrators.
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
3
4
1006 DC Millivolt Source
Time Electronics
Calibration, Test & Measurement

3 Ranges up to 1V

0.02% Accuracy

20 mA Output Current

Short circuit and overload protected

Safety terminals

Removable protective boot

Battery level indicator
The 1006 is an accurate low cost millivolt source suitable for voltage injection applications.
Three output ranges are provided to give adjustable output values from 1µV to 1V with a
basic 0.02% accuracy. For signal injection, the operator needs to switch on, check the
battery condition, select the range, and set the required voltage using the thumbwheel
switches. The 1006 uses a precision reference diode and low temperature co-efficient
resistors to give a highly stable output.
Power is provided by 6 AA batteries. Battery life is several months, depending on usage.
The battery condition is monitored by an indicator, which is mounted on the top of the unit.
The 1006 has up to 20 mA drive current and is short circuit and overload protected. An
off/normal/reverse output polarity switch is provided.
Safety Terminals: Fully compatible with 4mm shrouded plugs, as well as standard plugs,
bare wires, and spade terminals.
Added Protection: The 1006 comes fitted with an ergonomic rubber boot (9028) providing
increased protection and durability. The boot has a textured grip for comfortable handling
and openings at the top and bottom to allow access to the battery meter and a position to
place labels if required. The boot is easy to remove if the user prefers a stand-alone unit or
to house the 1006 in the 9027 carry case.
As an accurate millivolt source, the 1006 can be used for many applications including
thermocouple simulation (using appropriate lookup table), chart recorder calibration, A/D
converter and DMM calibration, and as a stable voltage for backing off DC offsets.
Unit comes supplied with dry cell batteries.
www.timeeusa.com
4
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
5
1006 Technical Specifications
Output:
0-999.9mV in 3 ranges
0-999.9mV in 0.1mV steps
0-99.99mV in 10µV steps
0-9.999mV in 1µV steps
Accuracy:
± 0.02% of setting +  0.02% of range + ± 1µV.
Output Resistance:
Less than 0.2 on 1 V and 100 mV ranges. 1 on 10mV range.
Maximum Output Current:
1V and 100mV ranges –20mA. 10mV range – Up to short circuit
value although it should be noted that loads of less than 1k will
give greater than 0.1% error.
Output Voltage Stability:
Less than 60 ppm/ºC. Less than 100 ppm per 3 months. (Non-cumulative)
Operative Temperature:
- 10ºC to + 60ºC.
Output Polarity:
Positive or negative switch selected. A centre ‘off’ position is also provided.
Output Noise Level:
Less than 30 ppm of f.s.
Reference Source:
Precision zener diode, selected for stability and low temperature co-efficient.
Maximum Overload:
The instrument can withstand continuous short circuit on the output
for all ranges.
Power Supply:
6-AA size batteries. A battery condition display indicates when the batteries
should be changed. An alternative power source is 6 NiCad cells of the same
dimensions. These can be recharged via a socket on the top of the unit.
The 6 rechargeable batteries and mains recharger are available as an
optional extra.
General Specification
Dimensions:
7.9 x 4.2 x 2.9” (200 x 107 x 74mm)
Weight:
2.4 lbs (1.1kg)
Optional Extras:
Rechargeable Battery Packs – 110V mains
Calibration Certificates
Ordering Information
Code
Description
1006
D.C. Millivolt Source Model (0.02% Accuracy)
9027
Leatherette Carry Case
9529
Rechargeable Battery Pack – (6 NiCad Cells + 240V Mains Charger)
9528
Rechargeable Battery Pack – (6 NiCad Cells + 110V Mains Charger)
9150
Factory Calibration Certificate
9100
UKAS/NIST Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
5
6
1007 DC Millivolt Potentiometer & Calibrator
Time Electronics
Calibration, Test & Measurement

3 Ranges up to 1V

0.02% Accuracy

20 mA Output Current

Short circuit and overload protected

Safety terminals

Removable protective boot

Battery level indicator
The 1007 can be used for potentiometric voltage measurement in addition to its operation as
a millivolt source. The null zero and sensitivity are adjustable via front panel controls maximum sensitivity enables null balance to resolve 3 microvolt.
The 1007 is suitable for calibration and simulation of thermocouples. Accurate voltages
equivalent to the output from a thermocouple can easily be set on a 1007, enabling fast
calibration of temperature measuring equipment. Alternatively, the 1007 can measure
thermocouples output by operating as a potentiometer.
Power is provided by 6 AA batteries. Battery life is several months, depending on usage.
The battery condition is monitored by an indicator, which is mounted on the top of the unit.
The 1007 has up to 20 mA drive current and is short circuit and overload protected. An
off/normal/reverse output polarity switch is provided.
Safety Terminals: Fully compatible with 4mm shrouded plugs, as well as standard plugs,
bare wires, and spade terminals.
Added Protection: The 1007 comes fitted with an ergonomic rubber boot (9028) providing
increased protection and durability. The boot has a textured grip for comfortable handling
and openings at the top and bottom to allow access to the battery meter and a position to
place labels if required. The boot is easy to remove if the user prefers a stand-alone unit or
to house the 1007 in the 9027 carry case.
Unit comes supplied with dry cell batteries. The source version of this instrument without null
measuring facility is also available (TE 1006).
www.timeeusa.com
6
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
7
1007 Technical Specifications
Output:
0 – 1V in 100uV steps, 0 – 100mV in 10uV steps, 0 – 10mV in 1uV steps.
Accuracy:
± 0.02% of setting, ± 0.02% of range. ± 1uV.
Output Resistance:
Less than 0.2 ohm on 1V and 100 mV ranges. 1 ohm on 10 mV range.
Max Output Current:
1V and 100mV ranges - 20mA. 10mV range - limited by 1ohm output resistance.
Output Stability:
Less than 60 ppm/°C. Less than 100 ppm per 3 months (Non cumulative).
Output Polarity:
Positive or negative switch selected. A centre 'off' position is also provided.
Output Noise Level:
Less than 30 ppm of range.
Reference Source:
Precision zener diode selected for stability and low temperature coefficient.
Power Supply:
Six AA size batteries. A battery condition indicator is provided. Rechargeable
NiCad cells may be used and charged without removal from the boot via the
charging socket on the top of the instrument. Rechargeable batteries and
mains charger are available as an optional extra.
Null Balance Display:
The null display is on a front panel meter, zero and sensitivity controls are
provided. Maximum sensitivity: ± 20 uV f.s.d. (3uV resolution); Minimum
sensitivity: ± 200 mV f.s.d.; Input resistance: Greater than 1 Mohm.
General Specification
Dimensions:
7.9 x 4.2 x 2.9” (200 x 107 x 74mm)
Weight:
2.4 lbs (1.1kg)
Optional Extras:
Rechargeable Battery Packs - 6 NiCad Cells plus mains charger.
Calibration Certificates
Ordering Information
Code
Description
1007
DC Millivolt Potentiometer & Calibrator
1006
D.C. Millivolt Source
9027
Leatherette Carry Case
9529
Rechargeable Battery Pack – (6 NiCad Cells + 240V Mains Charger)
9528
Rechargeable Battery Pack – (6 NiCad Cells + 110V Mains Charger)
9150
Factory Calibration Certificate
9101
NIST/UKAS Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
7
8
1010 DC Millivolt Calibrator
Time Electronics
Calibration, Test & Measurement

0.01uV to 10V

0.02% Accuracy

Battery / Mains operation

30mA Output Current

10 ppm/hr Stability

Safety Terminals
The 1010 is a solid state battery powered instrument suitable for applications requiring a
precision voltage source of low internal resistance. It has five ranges up to 10V with a
resolution up to 0.01uV. Its small size, robust construction and independence of mains
power make it easily portable and convenient for laboratory, field and industrial use.
Voltage outputs are set by selecting the range switch and dialling up the desired value on the
thumbwheel switch. Output polarity may be selected using the normal/off/reverse switch.
The calibrator’s output resistance is typically 500m on the top 3 ranges. The maximum
output current that can be drawn on these ranges is limited to 30mA. This is to prevent
damage to the internal circuitry in the event of accidental short circuit, etc. The lower ranges
have an output resistance of 1 ohm and will supply current up to the short circuit value.
Operation is from battery or mains. When the calibrator is plugged into the mains supply, the
internal batteries are automatically recharged. The internal batteries will operate the
calibrator when unplugged from the mains. Battery condition can be monitored by the meter
on the front panel.
A precision zener diode is used as a reference source that provides an input to a F.E.T.
chopper amplifier system operating in a feedback stabilised mode. The gain value is
determined by a set of precision metal film resistors, selected by the 5-decade thumbwheel
switch on the front panel. The output voltage is variable from 0.01uV to 9.9999V in 5 ranges.
For complete reliability, the calibrator range switch employs two contacts in parallel for each
position in case one contact fails, ensuring the calibrator will still function correctly.
Applications include calibration, linearity, and gains stability measurements on DC amplifiers,
digital and electronic voltmeters, data loggers and chart recorders. It’s high 10ppm per hour
stability and very low noise levels are ideal for this type of application.
www.timeeusa.com
8
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
9
1010 Technical Specifications
Output:
0 – 9.9999V in 5 ranges
0 – 9.9999V in 100µV steps
0 – 999.99mV in 10µV steps
0 – 99.999mV in 1µV steps
0 – 9.9999mV in 0.1µV steps
0 – 999.99µV in 0.01µV steps
Accuracy:
10V & 1V ranges: ± 0.02% of setting + ± 0.005% of range.
100mV range: ± 0.05% of setting + ± 0.005% of range, ± 1 µV.
10mV & 1mV ranges: ± 0.05% of setting + ± 0.005% of range, ± 4 µV.
Output Resistance:
10V, 1V, & 100mV ranges Less than 0.1 ohm (typically 0.05 ohms). 10mV & 1mV
ranges 1 ohm.
Maximum Output Current:
10V, 1V & 100mV ranges –30mA. 10mV & 1mV ranges – up to short circuit value
although it should be noted that loads of greater than 1kohm will give greater than
0.1% error.
Maximum Overload:
The instrument can withstand continuous short circuit on the output for all ranges.
The 10V, 1V and 100mV ranges have an automatic output current limit set at
approximately 30 mA.
Output Voltage Stability:
Less than 30ppm per ºC (0 to +50ºC). Less than 5ppm per V variation in supply
voltage. Less than 75ppm per year. Less than 10ppm per hour at constant
temperature.
Output Polarity:
Positive or negative switch selected. A centre ‘off’ position is provided.
Output Noise Level:
10V, 1V 100mV ranges – less than 10ppm of setting ± 2 µV (0-10Hz). 10mV & 1mV
ranges – less than ± 0.05µV (0-10 Hz).
Reference Sources:
Precision zener diode selected after a special ageing process for a temperature
coefficient better than 5 ppm per ºC and stability better than 10ppm per month, non
cumulative.
Power Supply:
Time Electronics power unit type PU2 which is housed in the rear of the 1010. The
PU2 will power the 1010 direct from the mains or an internal rechargeable battery.
The battery is automatically charged when mains power is connected. Access to the
power supply is from the back of instrument.
Battery Level Indicator:
A front panel display provides a continuous indication of the battery state.
General Specification
Dimensions:
8.5 x 6.9 x 7.5” (215 x 175 x 190 mm)
Weight:
7.3lbs (3.3kg)
Optional Extras:
Carrying Case
Factory Calibration Certificate
UKAS/NIST Calibration Certificate
Ordering Information
Code
Description
1010
DC Millivolt Calibrator
9021
Carrying Case
9151
Factory Calibration Certificate
9102
UKAS/NIST Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
9
10
1021 DC Current Source with Null Indicator
Time Electronics
Calibration, Test & Measurement

100mA output with overload protection

0.02% Accuracy

Wide range of applications

Safety terminals

Removable protective boot

Battery level indicator
The 1021 is a precision DC Current Source suitable for calibration and test applications from
micro-amp levels up to 100mA.
The 100mA output with overload protection is based on the popular Time Electronics type
1007 millivolt source and incorporates many of the well-proven features. The instrument is
overload protected and a front panel indicator shows when insufficient drive voltage is
available. Maximum output voltage is adjustable between 14 volts and 40 volts, with a
maximum output power of 2.4 watts.
The unique circuit design ensures that it stays well within specification for at least 12 months.
Variation with temperature is better than 60 ppm per ºC, and typically better than 20 ppm per
hour at constant temperature. To improve the switch reliability, additional back-up contacts
have been used – even if a contact fails, the 1021 will still operate correctly.
The accuracy and stability are such that a wide range of applications are possible. In the
process industries it may be used to test and calibrate current sensitive transducers, and
their associated indicating and recording instruments. The semiconductor industry requires
constant current sources for parameter measurements. It may also be used to measure DC
current accurately by using the null facility to back off the unknown current. Resolution of
1µA is possible.
The 1021 is housed in a robust metal case and a removable protective boot is supplied as
standard. The front panel safety terminals are compatible with 4mm shrouded plugs, as well
as standard plugs, bare wires, and spade terminals.
Rechargeable batteries give portable operation and a mains re-charger is supplied with the
unit. Complete recharge time is 10-12 hours although sufficient charge for a few hours
operation can be obtained with only 1/2 hours’ charge. Overnight recharge is sufficient to
fully charge the batteries, which give up to 10 hours of typical operation. The mains recharger is supplied as standard with the 1021 and connects with a socket on the top panel.
www.timeeusa.com
10
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
11
1021 Applications
Transducers
The ability to source and measure current makes the 1021 ideal for testing and calibration of many types of
current transducer and their associated measuring equipment.
Semiconductor Parameters
The 1021 covers many applications in a wide variety of semiconductor measurements including; forward
voltage drops, zener diode characteristics and temperature coefficients, transistor gains (hfe) and saturation
voltages. Characteristic curves of devices can be easily plotted by selecting suitable output currents on the
1021. It can also be used to drive Hall effect devices.
Resistance and Temperature Measurement
Low ohm and contact resistance of relays, switches, connectors, etc can be easily measured using the 1021
as the current source in a 4-terminal kelvin system where lead and probe resistance do not affect the
accuracy of the reading. This method can also be used in thermometry for calibration and measurement of
platinum-resistance thermometers and thermistors.
1021 Technical Specifications
Output:
0 - 99.99mA in 3 ranges: 0 - 99.99mA in 10µA steps
0 - 9.999mA in 1µA steps
0 - 999.9uA in 0.1µA steps
Accuracy:
+/- 0.02% of setting +/- 0.02% of range +/- 0.02uA
Voltage Capacity:
Adjustable between 14 and 40 volts. Maximum output power 2.4 watts.
Out of Limit Warning:
A front panel indicator provides indication of insufficient drive voltage.
Output Polarity:
Positive or negative switch selected. A centre ‘off’ position provides an
open circuit on the output terminals.
Output Stability:
Better than 60 ppm per ºC (-10 ºC to +50 ºC). Better than 25 ppm per hr
(at constant temperature).
Output Noise:
Less than 15 ppm of full scale
Load Regulation:
Better than 20 ppm per volt change in output.
Null Sensitivity:
Adjustable from ± 20mA to ± 20µA FSD via front panel control. Maximum
resolution is 1µA.
Power Supply:
NiCad rechargeable batteries with external mains re-charger. Standard
mains voltage is 220-250 50/60 Hz. 100-125 V 50/60 Hz is available but
should be specified on ordering.
General Specification
Dimensions:
7.9 x 4.2 x 2.9” (200 x 107 x 74mm)
Weight:
2.4 lbs (1.1kg)
Optional Extras:
Carry Case
Calibration Certificates
Ordering Information
Code
Description
1021
DC Current Source with Null Meter (mains charger and protective boot included)
9027
Leatherette Carry Case
9153
Factory Calibration Certificate
9105
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
11
12
1024 DC Current Calibrator
Time Electronics
Calibration, Test & Measurement
 Up to 100mA output
 0.02% accuracy
 10 ppm/hr stability
 Null facility
 Portable
 Battery & mains operation
The 1024 is a solid state battery powered instrument which is easily portable and convenient
for laboratory, field, or industrial use. It incorporates many of the well-proven circuit
techniques of the Time Electronics Type 1010 DC Voltage Calibrator.
The null balance system enables the 1024 to be used for making accurate current
measurement in addition to its basic function as a calibrator. Operation is by backing the
current source output against the current to be measured, with the difference being
displayed on a sensitive centre zone null meter. At the null point, there is no voltage drop
across the 1024.
The 1024 employs a precision aged reference diode as a basic reference source. Excellent
zero stability is ensured by the use of a high performance FET chopper amplifier system.
Precision metal film resistors with temperature co-efficients of less than 10 ppm per ºC are
used to maintain the accuracy and stability of the initial calibration.
Operation is from battery or mains. A front panel indicator that also serves as a supply on-off
display monitors the battery supply condition. A minimum line on the indicator shows when
the batteries should be recharged. Charging is performed by its own internal charger/power
supply. Simply plugging the 1024 into a mains supply will charge the batteries. Operation of
the 1024 may be continued when plugged into the mains.
Applications include calibration and testing of current sensitive transducers; calibration and
linearity tests on digital and electronic current meters; and semiconductor parameter
measurements e.g. diode conduction voltages at specified current levels.
www.timeeusa.com
12
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
13
1024 Technical Specifications
Output:
0 – 100 mA in 5 ranges:
0 – 99.999 mA in 1 µA steps
0 – 9.9999 mA in 100 nA steps
0 – 999.99 µA in 10 nA steps
0 – 99.999 µA in 1 nA steps
0 – 9.9999 µA in 0.1 nA steps
Accuracy:
± 0.02% of setting + ± 0.005% of range + ± 0.2 nA
Voltage Capacity:
15 V with new batteries or mains power (11 V with minimum allowable
battery volts).
Regulation:
Load: better than 5 ppm per volt. Supply: better than 5 ppm per volt.
Output Polarity:
Positive or negative switch selected. A centre ‘off’ position provides an open
circuit on the output terminals.
Out of Limit Warning:
A front panel LED indicator provides warning of insufficient drive voltage.
Output Stability:
Less than 30 ppm per ºC (0ºC to + 50ºC)
Less than 10 ppm per hour at constant temperature.
Less than 75 ppm per 6 months.
Output Noise:
100mA, 10mA and 1mA ranges: less than 5 ppm of full scale.
100uA and 10uA ranges: less than 10 ppm of full scale ± 0.1nA.
Null Sensitivity:
Adjustable from ± 25 mA to ± 25 µA FSD via front panel control. Maximum
resolution is 0.5 µA.
Power Supply:
Time Electronics power unit type PU2 is housed in the rear of the 1024. The
PU2 will power the 1024 direct from the mains or an internal rechargeable
battery. The battery is automatically charged when mains power is
connected. Access to the power supply is from the back of instrument.
Battery Level Indicator:
A front panel display provides a continuous indication of the battery state.
General Specification
Dimensions:
L 8.7 x H 6.3 x D 7.9” (220 x 160 x 200mm)
Weight:
7.2lbs (3.3 kg) including power unit
Optional Extras:
Carry Case that houses the 1024 with a leather shoulder strap and leads
compartment. The 1024 can be operated without removing it from the case.
Calibration Certificates
Ordering Information
Code
Description
1024
DC Current Calibrator with null measuring facility
9021
Carrying Case
9154
Factory Calibration Certificate
9106
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
13
14
1017 Multifunction DC V/I/R Calibrator
Time Electronics
Calibration, Test & Measurement
 DC Volts 10nV to 100V
 DC Current 100nA to 100mA
 Resistance 10m to 10k
 0.005% (50ppm) accuracy
 1 ppm setting resolution
 Noise < 2ppm (0.1 to 1Hz)
 Stability <5ppm/day <25ppm/yr
The 1017 is a high performance portable DC calibrator for use in the field or laboratory. It is
constructed in a durable, compact plastic case with a tilt stand/carry handle.
Five DC voltage ranges from 10mV to 100V full scale are available, each with a 6-digit
(1ppm) resolution. The DC current range is 100mA full scale with a 100nA (1ppm) resolution.
Resistance from 0.01 to 10k is available 0.01 steps.
The voltage, current and resistance ranges make it suitable for calibrating a wide range of
transducers, from thermocouples, 4-20mA and 0-10V transmitters, to Platinum Resistance
Thermometers, all in the same instrument.
Power
Mains or rechargeable battery. Battery operation enables good performance where earth
loop and noise pick-up occurs.
Stability v Temperature and Time
Outstanding performance is due to the use of special computer selected reference diodes
and the latest in resistor technology. The special low-thermal emf terminals reduce errors
when working with microvolt signals.
Digital Deviation Control
Allows the output to be increased/decreased in % terms from 0 to +/-0.999%. This provides a
direct read-out of error and simplifies the recording results for calibration certificates. It
enables the user to immediately see if the unit under test is within specification.
www.timeeusa.com
14
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
15
1017 Technical Specifications
Voltage Ranges/Accuracy:
0 - 9.99999mV in 10nV steps,
0 - 99.9999mV in 100nV steps,
0 - 999.999mV in 1µV steps,
0 - 9.99999V in 10µV steps,
0 - 99.9999V in 100µV steps,
± 0.02% of setting ± 0.005% of range
± 0.01% of setting ± 0.004% of range
± 0.005% of setting ± 0.002% of range
± 0.005% of setting ± 0.002% of range
± 0.01% of setting ± 0.004% of range
The above accuracies are independent of thermal emfs which can be
2uV or more depending on the type of leads and connections used.
Output resistance:
10mV & 100mV: 10. 1V & 10V: <150m. 100V: <1
Drive current max:
10&100mV: as 10 o/p resistance. 1V&10V: 150mA; 100V: 10mA.
Current Range/Accuracy:
0 - 99.9999mA in 0.1uA steps, ± 0.02% of setting + ± 0.004% of range.
Drive voltage max: 10V
Resistance Range/Accuracy:
0 - 9.99999k in 0.01 steps, ± 0.05% of setting +/- 0.003% of range.
Power rating:
0.25W per resistor
End resistance: less than 200m
Deviation Control:
0% to 0.999% in 0.001% steps. Deviation accuracy: V&I output, 0.5%.
Temperature Coefficient:
<5 ppm per ºC
Long Term Stability:
<5ppm/day, <15ppm/90day, <25ppm/year
Short Term Stability – Noise:
10mV range: <0.2uV/sec, <0.3uV/10sec, <0.4uV/min
100mV range: <0.2uV/sec, <0.4uV/10sec, <0.6uV/min
1V range:
<0.2uV/sec, <0.5uV/10sec, <1.5uV/min
10V range:
<1.0uV/sec, <2.0uV/10sec, < 8.0uV/min
100V range: <40uV/sec, <100uV/10sec, <500uV/min
100mA range: <0.2uA/sec, <0.4uA/10sec, <1.0uA/min
Warm-up and Settling time:
Warm-up: <10 mins to full accuracy. Settling: < 0.5 secs, 100V range 5 secs.
Output Connections:
The output is via low thermal emf terminals (0.2uV/ºC). A mains earth
terminal is provided for screening purposes. Output polarity can be
selected by a switch on the front panel.
Power Supply:
The 1017 can be powered continuously from a 230V 50/60 Hz (110V to
order) mains supply, or from the internal rechargeable NiCad battery pack.
A front panel indicator shows the state of charge at all times.
Operating temperature:
0 to 50ºC (32 to 120ºF). 15 to 25ºC for optimum performance.
Operating Humility:
10 to 90% non-condensing 25ºC (77ºF)
General Specification
Dimensions:
11.4 x 9.8 x 4.3” (290 x 250 x 110mm)
Weight:
5.4 lb (2.4 kg)
Optional Extras:
Calibration Certificates
Ordering Information
Code
Description
1017
Multifunction DC V/I/R Calibrator
9152
Factory Calibration Certificate
9109
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
15
16
1030 MicroCal Voltage & Current Source
Time Electronics
Calibration, Test & Measurement
 10mV, 100mV, 1V ranges
 10mA, 100mA ranges
 0.1% accuracy
 0 - 8V available
 Precision 10-turn dial
 Battery Powered 9V PP3
 Battery level indicator
The 1030 is a compact, low cost, portable voltage and current calibrator for general purpose
signal injection. It is suitable for voltage and current loop signal simulation as well as
thermocouple simulation. The precision 10-turn dial provides a conventional feel to setting
the output with a setting resolution of 1 part in a 1000 (0.1%)
Three voltage ranges give an adjustable output from 10uV to 1V and two current ranges for
10uA to 100mA.
An additional 0 to 8V output can be obtained by using a precision 1Kohm resistor that is
supplied with the unit. The resistor is connected across the output terminals and the 10mA
current range selected. This allows the output to be set between 0 and +/- 8V with a 10mV
resolution and an accuracy of 0.3% of full scale.
The 1030 is simple to operate and does not require any standardisation prior to use. The
operator needs only to switch on, check the battery condition, and set the required range and
output value.
The 1030 is supplied with a leatherette carry case.
www.timeeusa.com
16
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
17
1030 Technical Specifications
Voltage Ranges:
0 – 1V (1mV resolution)
0 – 100mV (100uV resolution)
0 – 10mV (10uV resolution)
0 – 8V (10mV resolution), using external precision 1Kohm resistor (included)
Current Ranges:
0 – 100mA (100uA resolution), 0 – 10mA (10uA resolution)
Accuracy:
Voltage:
10mV: 0.2% of full scale
100mV: 0.1% of full scale
1V: 0.1% of full scale
8V: 0.3% of full scale (using 1Kohm resistor & current o/p)
Current:
10mA: 0.2% of full scale
100mA: 0.2% of full scale
Linearity:
0.15%
Temperature Coefficient:
150ppm per °C
Noise:
30ppm of full scale (1V range)
Battery:
PP3 size, 9V. Approx 60 hours life. An optional alternative power source is a
NiCad or Ni-Mh rechargeable cell of the same type. This can be recharged
via the socket on the top of the unit without removing the cell from the unit.
Battery Condition:
Monitored by front panel indicator.
Output Polarity:
Positive or negative, switch selected. A centre ‘off ‘ position is also provided.
Maximum o/p Current:
1V, 100mV ranges: 20mA, 10mV, 8V ranges: Limited by output resistance.
Maximum o/p Voltage:
8V (current ranges)
Output Resistance:
0.2ohms on 1V and 100mV range
10ohms on 10mV range, 1Kohm on 8V range
Maximum Overload:
The 1030 can withstand continuous open circuit or short circuit on all ranges.
General Specification
Dimensions:
4.5 x 2.4 x 2.2 (115mm x 62mm x 55mm)
Weight:
1.1lb (0.5kg)
Optional Extras:
Rechargeable Battery Pack: A mains recharger and NiCad rechargeable
battery are available. The battery can be recharged without being removed.
Calibration Certificates – Factory and NIST
Ordering Information
Code
Description
1030
MicroCal (Combined Voltage and Current Source)
1031
Rechargeable Battery Pack (NiCad Battery and 240V Mains Charger)
1032
Rechargeable Battery Pack (NiCad Battery and 110V Mains Charger)
9155
Factory Calibration Certificate
9110
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
17
18
1044 Voltage and Current Calibrator
Time Electronics
Calibration, Test & Measurement

Source and Measure
Current and Voltage

3 Voltage Ranges: 0 – 20V

3 Current Ranges: 0 – 20mA

0.05% Accuracy

Portable with carry case
The 1044 is an accurate, low cost portable calibrator designed for use in a wide range of
applications. High performance and ease of use make it suitable for test engineers, R&D,
service, and calibration technicians.
Offering both versatility and practicality the 1044 can source and measure voltage and
current. The 0.05% accuracy is ideal for simulation and calibration in most engineering
applications.
The 1044 combines the advantages of digital accuracy with analog controls. Progressing
from the familiar functions of the Time Electronics 1030 calibrator, the 1044 offers more
ranges, better accuracy and the ability to measure as well as source.
The large, easy to read LCD display shows the actual output, even when the connected load
exceeds the specifications. This important feature eliminates the risk of large errors when
connecting to unknown loads. The display also shows if the battery becomes low.
In the source mode, voltage up to 20V and current up to 20mA may be generated in three
ranges. When in current source mode the 1044 has a high 24V compliance voltage which is
ideal for powering process control loops.
In the measurement mode, the range and function can be easily selected with the measured
input accurately shown on the LCD display, operating in a similar way to a multimeter.
The 1044 is housed in a pocket sized, ABS case and comes with a leatherette carry case
containing a compartment for storing test leads. Connections are by standard 4mm plugs or
by simply clamping the wires under the terminals.
A single 9V battery powers the unit or an external 12V DC power supply may be used which
disconnects the internal battery.
www.timeeusa.com
18
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
19
1044 Applications
In the source mode, the 1044 may be used to calibrate
meters, thermocouple indicators, data loggers, for
signal injection, semiconductor characterisation or as a
backing off source.
In the measure mode, the 1044 may be used in the
same way as a multimeter.
1044 Technical Specifications
VOLTAGE SOURCE
Ranges:
0 – 200mV / 100uV resolution
0 – 2V / 1mV resolution
0 – 20V / 10mV resolution
VOLTAGE MEASURE
Ranges:
0 – 200mV / 100uV resolution
0 – 2V / 1mV resolution
0 – 20V / 10mV resolution
Accuracy:
0.05% of full scale + 2 Counts
Accuracy:
Output Curr:
20mA Max
0.05% of full scale + 2 Counts
T / C & Noise: 150ppm/ºC Noise <30ppm
CURRENT SOURCE
Ranges:
0 – 200uA / 100nA resolution
0 – 2mA / 1uA resolution
0 – 20mA / 10uA resolution
CURRENT MEASURE
Ranges:
0 – 200uA / 100nA resolution
0 – 2mA / 1uA resolution
0 – 20mA / 10uA resolution
Accuracy:
0.05% of full scale + 3 Counts
Accuracy:
Output Volt:
24V Nominal
0.05% of full scale + 3 Counts
T / C & Noise: 200ppm/ºC Noise <50ppm
General Specification
Dimensions:
5.6” x 2.9” x 2.0”
Weight:
0.6lbs
Optional Extras:
Mains power supplies (110V and 230V)
Calibration Certificates
Ordering Information
Code
Description
1044
Voltage and Current Calibrator
7643
230V AC 50/60Hz Mains Power Supply
7652
110V Mains Power Supply
9156
Factory Calibration Certificate
9133
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
19
20
1048 Current - Voltage - Loop Calibrator
Time Electronics
Calibration, Test & Measurement

Source & Measure - Current & Voltage

3 Source ranges 0 - 22mA & 0 - 22V

3 Measure ranges 0 - 70mA & 0 - 50V

Transmitter Simulator/Sink

Output Steps and Ramps

Fine adjustment (Inching)

Accuracy 0.02% of span
The 1048 is a current, voltage, and process loop calibrator that covers the needs of an R&D
lab and process control engineer. Source and measure in three current and voltage ranges
plus a transmitter simulator/sink function. It has 4.5 digit (0.005% of span) resolution.
Output functions include step, ramp and inching. There are no key press menus to learn, just
switches and buttons. A multi-turn potentiometer controls the output with up/down
incrementing buttons for fine control. The output can be reversed (+/-) and zeroed at the flick
of a switch. The front panel features a large easy-to-read 4.5 Digit LCD display which autoranges. Manual reset of the ramp function is also provided for quick restore.
1048 Applications
2 w ire transducer/transmitter
Receiving instrument
Sensor
+
-
+
-
Read Mode
Source Mode
Controller
+
Pow er Supply
2 w ire transducer/transmitter
+
Sensor
+
-
Pow er
Supply
Read & Power Mode
Sink Mode (transmitter simulator)
www.timeeusa.com
20
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
21
1048 Technical Specifications
DC CURRENT - Source and Measure
Span:
0 - 22mA, over-range to 70mA for
measure only
Accuracy:
0.02% of span
Resolution:
1uA (0-19.999mA), 10uA (above 20mA)
DC VOLTS - Source and Measure
Span:
0 - 22V, over-range to 50V for measure
only
Accuracy:
0.02% of span
Resolution:
1mV (0-19.999V), 10mV (above 20V)
Span:
Accuracy:
Resolution:
0 - 2.2mA
0.02% of span
0.1uA (0-1.9999mA),1uA (above2mA)
Span:
Accuracy:
Resolution:
0 - 2.2V
0.02% of span
100uV (0-1.9999V), 1mV (above 2V)
Span:
Accuracy:
Resolution:
0 - 220uA
0.05% of span
10nA (0-199.99uA), 0.1uA (above 200uA)
Span:
Accuracy:
Resolution:
0 - 220mV
0.05% of span
10uV(0-199.99mV), 0.1mV (above 200mV)
Output res:
Measure load:
Approx <2 ohms. Max current 50mA
1Mohm on all ranges
Max source load: 1.1Kohms @ 20mA. Max drive: 22V
Measure load:
1K,110,16 ohm for 0.22, 2.2, 22mA
SINK (TX SIM)
2 wire transmitter simulation: External excitation voltage, 3V min, 50V max. The current sink levels are adjustable, with
accuracies as in the 3 source ranges shown above.
Note: Accuracies in all measure modes are +/-1 digit
OUTPUT STEPS
5 fixed 4mA steps for current output 4, 8, 12, 16 & 20 mA
11 fixed 1V steps for voltage output 0,1,2...10V
21 fixed steps 1V/1mA for V & I output 0,1,2…...20
Stepping can be done manually or automatically (Autostep) Stepping speed is adjustable (1-9 sec/step). Dwell time (top
and bottom) is one step period. In step mode the accuracy is limited to 0.05% of span +/-1digit.
OUTPUT RAMP
Current Ramp 4 to 20, or 0 to 20 on all ranges.
Voltage Ramp 0 to 10, or 0 to 20 on all ranges.
Ramp time 7sec. Dwell (top/bottom) 5sec. Manual restart.
Ramp operation is also available in Sink (TX SIM).
OUTPUT ADJUSTMENT
A ten turn potentiometer is provided for quick positioning with fine adjust using up/down incrementing buttons.
Power: A single internal 9V PP3 size battery or an optional external mains power supply. Battery life: Typically about
15hrs use. Continuous operation in current source mode will shorten the battery life. A 15 min inactivity auto-power down
feature is also included to conserve the battery.
Operating temperature: -10 to 50 °C (14 to 120 °F)
Storage temperature: -30 to 70 °C (-22 to 160 °F)
Operating humidity: 10-90% non-condensing at 25 °C
General Specification
Dimensions:
5.6 x 2.9 x 2.0” (142 x 78 x 50mm)
Weight:
0.6lbs (0.28kg)
Housing:
A pocket sized hard ABS case in a leatherette carry case. Leads can be stored inside of the case.
Optional Extras: External Power Unit: 230 or 110V mains power supply
Calibration Certificates
Ordering Information
Code
Description
1048
V - I - Loop Calibrator 0.02%
7643
230/240V AC 50/60Hz Mains Power Supply
7652
110V Mains Power Supply
9176
Factory Calibration Certificate
9138
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
21
22
1049 Class A °C PT100 Simulator
Time Electronics
Calibration, Test & Measurement

-200°C to + 800°C

± 0.3°C accuracy

Based on ITS 90 EN60751

23 set points

Exceeds Class A

Good temperature stability

Passive resistance source
The 1049 is a portable precision simulator for PT100 0.3850 platinum resistance elements used for accurate
temperature measurement.
It follows the PT100 scale from –200°C to +800°C with 23 set points. High performance metal film resistors are
used throughout which ensures a good temperature coefficient and long term stability.
The specification is in accordance with DIN EN 60751 (ITS 90). Offering high accuracy across the full operating
range of PT100 devices it exceeds the performance of Class A & B. The 1049 will be of particular interest to
those operating in the –60 to +60°C range where a performance exceeding Class A (e.g. better than +/- 0.15°C
at 0°C), is required.
Since the 1049’s output is a purely passive resistance it will operate with all types of PT100 measuring
equipment including the live systems using pulsed, or interrupted excitation current.
1049 Technical Specifications
Set points °C:
-200, -100, -50, -20, -10, 0, 10, 20, 30, 40, 50, 60, 80,
100, 150, 200, 250, 300, 400, 500, 600, 700, 800.
Accuracy:
-200 to -100°C ± 0.3°C
-50 to +60°C ± 0.15°C
+80 to +200°C ± 0.3°C
+250 to +500°C +/- 0.5°C
+600 to +800°C +/- 0.65°C
Temp Coefficient:
Less than 30 ppm per °C
Maximum Current:
50 mA
General Specification
Dimensions:
2.4 x 5 x 2.2“ (61 x 112 x 55 mm)
Weight:
0.4lb (170g)
Supplied with:
2 year warranty, test leads, factory certificate, and leather carry pouch
Optional Extras:
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
1049
9114
Description
Handheld PT100 °C Simulator
UKAS/NIST Traceable Calibration Certificate
www.timeeusa.com
22
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
23
1050 Class A °F PT100 Simulator
Time Electronics
Calibration, Test & Measurement

-100°F to 1000°F

± 0.5°F accuracy

Based on ITS 90 EN60751

23 set points

Exceeds Class A

Good temperature stability

Passive resistance source
The 1050 is a precision simulator for PT100 0.3850 Platinum Resistance elements used for accurate
temperature measurement.
It follows the PT100 scale from –100°F to +1000°F with 23 set points. High performance metal film resistors are
used throughout which ensures a good temperature coefficient and long term stability.
The specification is in accordance with DIN EN 60751 (ITS90). Offering high accuracy across the full operating
range of PT100 devices it exceeds the performance of Class A & B. The 1050 will be of particular interest to
those operating in the –80 to +140°F range where performance exceeding Class A e.g. better than +/- 0.3°F at
32°F, is required.
Since the 1050’s output is a purely passive resistance it will operate with all types of PT100 measuring
equipment including the live systems using pulsed, or interrupted excitation current.
1050 Technical Specifications
Set points °F:
-100, -50, -25, 0, 32.2, 50, 75, 100, 125, 150, 175, 200,
225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 1000
Accuracy:
-100 to 300 °F +/- 0.5 °F
300 to 1000 °F +/- 0.9 °F
Temp Coefficient:
Less than 25 ppm per °F
Maximum Current:
50 mA
General Specification
Dimensions:
2.4 x 5 x 2.2“ (61 x 112 x 55 mm)
Weight:
0.4lb (170g)
Supplied with:
2 year warranty, test leads, factory certificate, and leather carry pouch
Optional Extras:
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
1050
9114
Description
Handheld PT100 °F Simulator
UKAS/NIST Traceable Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
23
24
1077 Milliamp Transducer/Simulator
Time Electronics
Calibration, Test & Measurement

3 Operating modes

100mA Source & Load

24V Line mode

0.02% Accuracy

Safety terminals

Removable protective boot

Battery level indicator
The 1077 is a hand held instrument designed for the testing and simulation of milliamp
transducer system. Its rugged and compact construction makes it ideal for use in the field or
laboratory.
Three operating modes are possible 1) As an adjustable current load (simulating the transducer) on the line, the 1077 will draw
up to 100mA from the line. The required current is set by the front panel controls.
2) As an adjustable power supply (14V to 40V) with accurate measurement and display of
the current drawn from the circuit.
3) As a precision current source with 14V to 40V max. (adjustable) drive capacity. The
1077 will source the set current up to 100mA to the loop.
Safety Terminals: Fully compatible with 4mm shrouded plugs, as well as standard plugs,
bare wires, and spade terminals.
Added Protection: The 1077 comes fitted with an ergonomic rubber boot (9028) providing
increased protection and durability. The boot has a textured grip for comfortable handling
and openings at the top and bottom to allow access to the battery meter and a position to
place labels if required. The boot is easy to remove if the user prefers a stand-alone unit or
to house the 1077 in the 9027 carry case.
The versatile capabilities make the 1077 ideal for process control engineers. It is supplied
with rechargeable batteries, mains charger, and protective boot as standard.
www.timeeusa.com
24
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
25
1077 Technical Specifications
CURRENT LOAD (TRANSDUCER SIMULATION)
Output:
0 to 100mA in 3 ranges:
0 – 99.99mA in 10µA steps
0 – 9.999mA in 1µA steps
0 – 999.9µA in 0.1µA steps
Accuracy:
± 0.02% of setting; ± 0.02% of range; ±0.02µA
Output Stability:
Better than 60 ppm per ºC. Better than 25 ppm per hour at constant temp.
Input Voltage:
30V maximum, 3V minimum
Voltage Limit Warning:
A front panel indicator provides indication of insufficient terminal voltage.
24 VOLT LINE SIMULATION
24 V Line Simulation:
Adjustable 14V to 40V, 100mA current limit, Maximum output power 2.4 W.
Display:
A 3.5 digit (1999 max) LCD display indicating line current.
Measure Range:
0 – 20mA
Resolution:
10µA
Accuracy:
0.2% of reading + 1 count
CURRENT SOURCE
Output:
0 to 100mA in 3 ranges –
0 – 99.99mA in 10µA steps
0 – 9.999mA in 1µA steps
0 – 999.9µA in 0.1µA steps
Accuracy:
± 0.05% of setting, ± 0.02% of range
Output Stability:
Better than 60 ppm per ºC. Better than 25 ppm per hour at constant temp.
Output Noise:
Less than 15 ppm of full scale
Voltage Capability:
Adjustable 14V – 40V
Output Power:
2.4 watts maximum
Output Limit Warning:
A front panel indicator provides indication of insufficient drive voltage.
Power Supply:
NiCad rechargeable batteries with external mains recharger. Recharge time
approximately 10 hours. Operating time typically 10 hours.
General Specification
Dimensions:
4.5 x 4 x 8” (110 x 75 x 200 mm)
Weight:
2.4 lb (1.1 kg)
Supplied with:
Protective boot, NiCad cells and mains charger.
Optional Extras:
Carry Case
Calibration Certificates
Ordering Information
Code
Description
1077
Transim (Milliamp Transducer/Line Simulator)
9027
Leatherette Carry Case
9158
Factory Calibration Certificate
9108
UKAS/NIST Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
25
26
1090 Temperature and Process Calibrator
Time Electronics
Calibration, Test & Measurement











Measure/Simulate 8 thermocouples
Measure/Simulate PT100
ITS 90 standard
Measure/Source (uV/mV/mA)
Display in °C and °F
Automatic CJC - selectable
10 point memory recall
Inching and Step functions
Mains/Battery + auto power down
Process loops 4-20mA and 0-50mA
24V loop drive voltage
The 1090 is a portable high performance process calibrator that combines source and measurement functions
for thermocouples, PT100s, uV, mV, and mA.
Thermocouple measurement and simulation
The unit can measure and simulate the temperature and mV characteristics of J, K, T, R, S, B, N and E
thermocouples.
Cold junction compensation
The unit can be operated with or without internal cold junction compensation.
PT100 measurement and simulation
Based on 0.3850 alpha probe standard.
Range is –200 °C to 700 °C.
Measurement and Source (uV, mV, and mA)
Measurement ranges are 0 to +/-30mV and 0 to +/-60mA.
Source ranges are 0 to +/-80mV and 0 to +80mA.
Temperature units selection
The display can be easily changed from °C to °F. The equivalent uV (thermocouples) and ohms (PT100) can
also be shown.
24V Process Loop drive mode
A process loop can be driven at 24V and up to 60mA by selecting the ‘Milliamp Source’ mode and setting it at
60mA (or a lower level if required).
Inching (Incrementing/Decrementing)
The unit has a general-purpose inching function. This adjusts the output in fixed increments of temperature
(thermocouples only) or voltage or current. The set-up menu gives a the user a choice of three levels of
increment i.e. 0.1, 1 or 10 for °C/°F, or 1, 10, or 100 uV/uA for voltage/current. The lowest of these represents
the highest setting resolution and provides the most precise control of the output. This is especially useful for
calibrating thermostat controllers that have tight specification on hysteresis.
Memory recall and step/auto-step functions
Up to 10 values can be stored in the unit’s non- volatile memory and they can be recalled at any time. The user
can also manually step through them in sequence using the step key. Continuous stepping (auto-step) is also
available at any user selectable rate between 1 and 10 seconds/step.
Power is via an internal high capacity re-chargeable metal hydride battery that can be re-charged from an
external mains charger (supplied as standard). The unit is supplied in a robust case with a carrying strap. A
pocket for the instruction manual is provided.
www.timeeusa.com
26
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
27
1090 Technical Specifications
MEASURE ACCURACY
SIMULATE ACCURACY
THERMOCOUPLE
TYPE
TEMPERATURE
RANGE °C
ACCURACY
°C
THERMOCOUPLE
TYPE
TEMPERATURE
RANGE °C
ACCURACY
°C
J
-200 to 580
0.7
J
-210 to 150
150 to 1200
0.15
0.3
K
-200 to –150
-150 to 750
2.5
0.5
K
-270 to 190
190 to 1250
0.5
0.4
T
-200 to 0
0 to 400
1.5
0.4
T
-200 to 150
150 to 400
0.4
0.5
R
-50 to 400
400 to 1750
3.0
1.5
R
-50 to 800
800 to 1750
0.8
2.0
S
-50 to 100
100 to 1750
3.0
1.5
S
-50 to 850
850 to 1750
0.9
2.0
B
110 to 1000
1000 to 1800
3.5
1.5
B
100 to 1200
1200 to 1800
2.0
3.0
N
-100 to 890
0.6
N
-270 to 260
260 to 1300
0.5
1.0
E
-50 to 400
0.4
E
-50 to 1000
0.3
Resolution: 0.1 °C or °F
Resolution: 0.1 °C or °F
An additional correction representing the equivalent 1µV should be allowed for stray thermal emf effects.
Cold Junction Compensation:
Operating Temperature:
Connections:
Power:
Accuracy 0.2 °C. Resolution 0.1 °C.
-10 to 40 °C (15 to 105 °F)
Industry standard 4mm screw terminals.
A metal hydride rechargeable battery pack gives approximately 60 hours continuous
operation. The mains re-charger supplied allows full recharge in 11 hours. To
conserve battery life, a user inactivity power-down feature is included.
Millivolt Source 0 to +/- 80mV
Accuracy (8 to 80mV):
0.02% of f.s.
Resolution (8 to 80mV):
5uV
Accuracy (0 to 8mV):
+/-4uV
Resolution (0 to 8mV):
0.5uV
Output resistance :
10 ohm
Milliamp Source 0 to +80mA
Accuracy (8 to 80mA):
0.02% of f.s.
Resolution:
5uA
PT100 Simulation
Accuracy (0 to 8mA):
+/-10uA
14 set temp. points: -100, -50, -20, 0, 20, 50, 100, 200, 300, Resolution:
0.5uA
400, 500, 600, 700, 800 °C
Max load (24V drive): 300R/80mA ,480R/50mA ,1.2K/20mA
Accuracy:
0.1% of resistance value (typically 0.5 °C) Inching
Three levels of increment, 0.1, 1 or 10 for °C/°F, and 1, 10,
PT100 Measure (0.2 °C or °F resolution)
or 100 uV/ uA for voltage/current. The lowest of these
Range:
-200 to 700 °C, 2 wire.
represents the highest setting resolution and provides the
Accuracy:
0.2% of resistance value (typically 0.7 °C)
most precise control of the output.
24V Process Loop drive mode
A process loop can be driven at 24V and up to 60mA by
Memory recall and step functions
selecting the ‘Milliamp Source’ mode and setting it at 60mA
10 memory locations for non-volatile storage of values.
Manual and Auto-Step, rate adjustable from 1 to 10 sec/step (or a lower level if required).
Millivolt Measure 0 to +/- 30mV
Resolution:
10µV
Accuracy:
0.05% of f.s. ±1 digit
Input resistance:
100K Ohms
Milliamp Measure 0 to +/- 60mA
Resolution:
20µA
Accuracy:
0.05% of f.s. ±1 digit
Input resistance:
0.5 ohms
General Specification
Dimensions:
Weight:
Optional Extras:
9.25 x 6 x 3” (235 x 150 x 75 mm).
2.8lbs (1.25 Kg)
Calibration Certificates
Ordering Information
Code
Description
1090
Temperature and Process Calibrator (including batteries, charger and carrying case)
9177
Factory Calibration Certificate
9139
UKAS/NIST Traceable Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
27
28
7000 RTD Temperature Calibrator
Time Electronics
Calibration, Test & Measurement

Temperature: Accuracy 0.05 °C (0.09 °F)
Resolution 0.01 °C (0.02 °F)

Resistance:

2, 3 and 4 Wire Connections

Read and Simulate °C, °F, °K, and Ohms

Ramp & Step

PT100 plus 7 other RTD types

User programmable

Supplied in protective carrying case
Accuracy 0.03Ω
Resolution 0.01Ω
The 7000 is a portable process control instrument that combines a precision Digital Thermometer (using RTD
probes) with an RTD/Ohms Calibrator.
Compact and easy to use, it solves the problem of making high accuracy temperature measurements without
using bulky mains powered instrumentation.
Powered from internal long life re-chargeable batteries or an external mains adapter, it is equally valuable in
laboratory, workshop or the field. It can also be used as an external temperature reference for dry block and
other precision temperature baths.
7000 Technical Specifications
MONITOR MODE (4 WIRE) FUNCTIONS
SIMULATOR MODE (4 WIRE) FUNCTIONS
1. Check RTD probes by measuring their resistance
at known temperatures.
2. Measure resistance values.
1. Output resistance of precise known value.
3. Indicate temperature when connected to an RTD
probe.
4. Can be pre-programmed with a particular RTD’s
characteristics to allow very high accuracy.
Excitation current:
Resistance range:
Resolution:
Accuracy:
Auto re-calibration:
Temperature stability:
Max/Min values:
1mA on all ranges
0.01Ω to 2.6kΩ
0.01Ω
See tables below
Every 0.6 secs.
Better than 0.0015%/°C
Logged automatically
The 7000 may be used with a calibrated and certified
probe to produce a highly accurate thermometer.
The performance can be further enhanced by
programming the actual characteristic of the probe
into the unit.
www.timeeusa.com
28
2. Simulate an RTD value from an RTD table chart.
3. Simulate an RTD value using the internal table.
Excitation current:
Resistance range:
Resolution:
Accuracy:
Auto re-calibration:
Temperature stability:
0.6mA to 1mA.
0.01 to 2.6kΩ
0.01Ω
See tables below
Every 0.6 secs
Better than 0.0015%/°C.
Enhanced performance may be achieved by
programming the unit to simulate the characteristic of
a particular probe.
Five fixed step points (0, 25, 50, 75, 100%) are
available between a user set minimum (0%) and a
maximum (100%). Programmable ramp function is
also available.
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
29
Standard RTD types (Non standard RTD types user programmable)
Element
Alpha Coeff.
Celsius
Range
Accuracy
-200 to 250
0.05 °C
250 to 849
0.07 °C
Fahrenheit
Range
Accuracy
-330 to 480
0.10 °F
480 to 1560
0.14 °F
Pt100 DIN
0.003850
Pt100 US
0.003916
-100 to 250
250 to 457
0.05 °C
0.07 °C
-150 to 480
480 to 850
0.10 °F
0.14 °F
Pt200 DIN
0.003850
-200 to 300
0.05 °C
-330 to 570
0.10 °F
Pt500 DIN
0.003850
-200 to 250
250 to 630
0.05 °C
0.07 °C
-330 to 480
480 to 1160
0.10 °F
0.14 °F
Pt1000 DIN
0.003850
-200 to 250
250 to 630
0.05 °C
0.07 °C
-330 to 480
480 to 1160
0.10 °F
0.014 °F
Ni 120
0.006180
-100 to 200
0.05 °C
-150 to 390
0.10 °F
Ni 1000
0.006180
-100 to 200
0.05 °C
-150 to 390
0.10 °F
Range ohms
20 to 400
400 to 800
800 to 1200
1200 to 2600
Monitor
0.03Ω
0.10Ω
0.20Ω
0.50Ω
Generator
0.03Ω
0.10Ω
0.20Ω
0.50Ω*
Resistance
Accuracy
*plus additional error of 0.05% of output value. If excitation current is less than 1mA.
General Specification
Operating temperature range:
–10 to 50oC
Battery power:
NiCad rechargeable
Mains power:
External mains adapter.
Battery life:
> 30hrs
Case:
Impact resistant ABS
Size:
6.5 x 3.5 x 1.8” (165 x 90 x 45 mm)
Weight:
0.9 lbs (0.40 kg)
Optional Extras:
Mains Adapter 230V AC, Mains Adapter 110V AC
Calibration Certificates
Ordering Information
Code
Description
7000
RTD Temperature Calibrator
7633
Mains Adapter 230V AC
7633
Mains Adapter 110V AC
9183
Factory Calibration Certificate
9194
NIST/UKAS Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
29
30
7005 Loop Calibrator
Time Electronics
Calibration, Test & Measurement
 Loop Source - Current or Voltage
 Loop Measure - Current or Voltage
 Loop Current Sink
 Accuracy 0.01%
 Resolution 1uA or 1mV
 Programmable Ranges
 Manual Step, Auto-Step and Ramp
 Square Root Functions for Flow
 20mA drive capability into 1100 ohms
The 7005 is a micro-processor based instrument for the calibration and simulation of voltage
and current loops. It can operate in three modes:
a) Loop current/voltage Source (simulating a transmitter and the loop supply)
b) Sink of loop current (simulating a transmitter)
c) Measurement of loop current/voltage (simulating a loop indicator).
Manual step of the output is available at five calibration points, 0%, 25%, 50%, 75% and
100% of span. Automatic stepping of the output is also available both up and down with
programmable dwell times.
Continuous up/down ramping is also available with user programmable ramp rates and dwell
time (top and bottom).
In source mode the range can be user programmed to any value between 0mA and 50mA,
or 0V and 21V. For example a low point of 10mA and a high point of 50mA could be set
giving a span of 40mA
Measure mode provides both voltage and current measuring capability with 5 digit resolution.
Ranges are 0 to ±5V and ±5 to ±25V, 0 to ±25mA and ±25 to ±125mA. Alternatively the
signal can be measured as a % of span for the following ranges, 4 to 20mA, 0 to 20mA,
square root 4 to 20mA, square root 0 to 20mA. For all measurements a Min/Max recording
function is available on demand.
An internal NiCad battery can power the unit for typically 9 hours and an external mains
charger is supplied as standard. An automatic power-down feature is incorporated to
conserve battery life.
www.timeeusa.com
30
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
31
7005 Technical Specifications
Measurement
Source
DC CURRENT 0 to ±125mA, Auto-ranging
Accuracy (0 to 25mA):
±0.01% of reading ±2uA
Resolution:
1uA
Accuracy (25 to 125mA): ±0.01% of reading ±20uA
Resolution:
10uA
Measure load:
24.5Ω on all ranges
DC VOLTS
0 to ±25V, Auto-ranging
Accuracy (0 to 5V):
±0.01% of reading ±0.4mV
Resolution:
0.1mV
Accuracy (5 to 25V):
±0.01% of reading ±2mV
Resolution:
1mV
Measure load:
10MΩ on all ranges
DC CURRENT 0 to 50mA
Accuracy:
±0.01% of setting ±2uA
Resolution:
1uA
Max drive:
22V
Loop Resistance:
1100Ω @ 20mA max
DC VOLTS 0 to 21V @ 50mA
Accuracy:
±0.01% of setting ±4mV
Resolution:
1mV
Output resistance:
< 1Ω
DC CURRENT SINK 0 to 50mA
Accuracy:
±0.01% of setting ±2uA
Resolution:
1uA
Min external drive:
4V
Max external drive:
40V
Summary of Functions
SOURCE MODE
 User programmable ranges - any values between 0 and 50mA or 0 and 21V.
 Fixed ranges are available: 4 to 20mA, 0 to 20mA, sqrt 4 to 20mA, sqrt 0 to 20mA.
 Fine adjustment (inching) is available for precise deviation from the calibration point.
 Manual step output - five calibration points 0%,25%,50%,75% and 100%
 Automatic step output (up/down) - five cal points with programmable dwell period.
 Ramp output - programmable ramp rate (0 to 20mA/Sec or 0 to 20V/Sec)
programmable dwell period (0 to 1000 seconds)
MEASURE MODE
This mode provides both voltage and current measuring capability with 5 digit resolution. Ranges are 0 to ±5V
and ±5 to ±25V, 0 to ±25mA and ±25 to ±125mA. Alternatively the signal can be measured as a % of span
for the following ranges, 4 to 20mA, 0 to 20mA, square root 4 to 20mA, square root 0 to 20mA. For all
measurements a Min/Max recording function is available on demand.
General Specification
Power:
Internal NiCad battery. Battery life typically >9 hours. Auto power-down.
External battery charger supplied
Dimensions:
6.7 x 3.5 x 2” (17 x 9 x 5 cm)
Weight:
0.8 lbs (0.42kg)
Housing:
Case Impact resistant ABS
Optional Extras:
Calibration Certificates
Unit comes supplied complete with lead set.
Ordering Information
Code
Description
7005
Loop Calibrator
9184
Factory Calibration Certificate
9195
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
31
32
7006/7007 Loop-Mates 1 and 2
Time Electronics
Calibration, Test & Measurement








Pocket sized 140 x 66 x 27 mm
4 - 20mA or 0 - 10V loops
7 calibration set-points
TxSim and RxTest (Loop-Mate1)
RxSim and TxTest (Loop-Mate2)
Auto-Step output - adjustable rate
Battery powered PP3
Internal loop drive supply
The Loop-Mates are single function low-cost pocket sized units, designed for test and calibration of process
loops. Simplicity of operation is their key - no keypads or complicated selections. Engineers will be able to pick
them up and get to work immediately. Just select 4 - 20mA, or 10V loop, and TxSim, RxTest, RxSim or TxTest.
Both have internal loop drive supplies, which can be used to power the loop if required.
Loop-Mate1 is the simulator and acts as a source to provide the loop signals, 4 - 20mA or 0 - 10V.
No complicated selection of the output, just operate up/down buttons to increase or decrease the signal. There
are 7 set-points, 0%, 10%, 25%, 50%, 75%, 90%, 100%. Each is indicated on a high brightness LED and an
audible beep sounds as you step between them. Auto-stepping mode (adjustable rate) allows Loop-Mate1 to
be left connected stepping up and down. The engineer can then move to another location to check (using LoopMate2) that the signal is arriving correctly and is within specification.
Loop-Mate2 is a dedicated loop signal indicator, just as easy to operate. Once again select the loop type, 4 20mA, or 0 - 10V, and whether you want the display in direct units, or % of span. The LCD display shows the
signal to an accuracy of 0.05% either in mA, V, or % of span.
Both units are powered by a single standard PP3 battery that gives up to 40hrs continuous use.
7006 & 7007 Technical Specifications
7006 Loop-Mate1
7007 Loop-Mate2
Range:
4 - 20mA, or 0 - 10V
Range:
4 - 20mA, 0 - 10V, 0 - 50V
Set-Points:
0, 10, 25, 50, 75, 90, 100% of span
Display:
LCD 4 digits, mA, V, or % of span
Accuracy:
0.1%
Accuracy:
0.05%
Modes:
TxSim, or RxTest
Modes:
RxSim, TxTest, or 50mA/50V measure
Loop Supply:
Internal, 25mA max
Loop supply:
Internal, 25mA max
Auto-Step:
Up/Down/Up, 0.5, 1, 2, 4, or 8sec/step
General Specification (Applies to both units unless stated)
Power:
PP3 battery, typical life 40hrs
Dimensions:
L 5.5 x W 6.6 x D 1.2” (L 140 x W 65 x D 30mm)
Weight:
7006: 0.4 lbs (180g)
7007: 0.44 lbs (200g)
Optional Extras:
Calibration Certificates
Loop-Mates are supplied with a carrying case, leads and technical manual.
Ordering Information
Code
Description
7006
Loop-Mate 1
7007
Loop-Mate 2
9145
Factory Calibration Certificate (7006 and 7007)
9144
UKAS/NIST Traceable Calibration Certificate (7006 and 7007)
www.timeeusa.com
32
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
33
5068 INSCAL Insulation Tester Calibration System
Time Electronics
Calibration, Test & Measurement








Insulation resistance from 100KΩ to 10GΩ
Low ohm verification at 1Ω, 10Ω, 100Ω, 1KΩ
Basic accuracy 1%
2.5kV max
Battery operation
Continuous connection - no arcing
Fully shrouded safety connectors
Display of open circuit voltage
(0 – 1.999kV or 0 – 2.50kV)
 Display of short circuit current
(0 - 2mA or 0 - 20mA)
The 5068 is a precision instrument suitable for calibrating and testing general purpose insulation testers with
test voltages up to 2.5kV.
It is constructed in a high strength co-polymer plastic case and is powered by a rechargeable battery. This
ensures full isolation from the mains and prevents stray leakage. The insulation tester being calibrated can be
tested for open circuit voltage and short circuit current. These are displayed on the digital meter mounted on
the front panel. Nine selectable precision resistors provide the insulation resistance test. Also fitted are 4 fixed
low resistance values for verification of the low ohm ranges and continuity.
Also available is the 5069, 10kV version, see separate data sheet.
5068 Technical Specifications
Resistance (Insulation):
Resistance (Low ohm):
Resistance accuracy
Resistance temperature coefficient:
Continuity:
10GΩ, 1GΩ, 400MΩ, 250MΩ, 100MΩ, 10MΩ, 1MΩ, 500KΩ, 100KΩ
1Ω, 10Ω, 100Ω, 1KΩ
Low Ohm 1%, Insulation resistance: 100KΩ - 1GΩ, 1%. 10GΩ, 5%
< than 250ppm/°C insulation resistance, < 50ppm/°C low resistance
Selectable 5Ω
Open circuit voltage measure:
Voltage display:
Voltage temperature coefficient:
0 to 2kV range, 0 to 2.5kV range, both ranges 1% of f/s accuracy
1.999kV full scale, and 2.50kV full scale
< than 300ppm/°C
Short circuit current measure:
Current display:
Current temperature coefficient:
0 to 2mA range, 0 to 20mA range, both ranges 1% of f/s accuracy
1.999mA full scale, and 19.99mA full scale
< than 450ppm/°C
Power:
Internal battery, 6V re-chargeable NiCad, >150hrs between charges
Above accuracies specified between 15°C - 25°C
General Specification
Dimensions:
Weight:
Supplied with:
W 10.6 x D 9.7 x H 6.9” (270W x 246D x 175H mm)
4.6 lbs (2.1Kg)
Safety connection leads to allow custom 4mm connectors and low resistance leads
Mains battery re-charger
Ordering Information
Code
5068
9189
9112
Description
INSCAL Insulation Tester Calibration System
Factory Calibration Certificate
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
33
34
5069 INSCAL Insulation Tester Calibration System
Time Electronics
Calibration, Test & Measurement







Insulation resistance from 100kΩ to 100GΩ
Basic accuracy 1%
10kV max
Battery operation
Continuous connection - no arcing
Fully shrouded safety connectors
Display of open circuit voltage
(0 – 2kV or 0 – 10kV)
 Display of short circuit current
(0 - 2mA or 0 - 20mA)
The 5069 is a precision instrument suitable for calibrating and testing general purpose insulation testers with
test voltages up to 10kV.
It is constructed in a high strength co-polymer plastic case and is powered by a rechargeable battery. This
ensures full isolation from the mains and prevents stray leakage. The insulation tester being calibrated can be
tested for open circuit voltage and short circuit current. These are displayed on the digital meter mounted on
the front panel. The insulation resistance is provided by a precision 4 dial decade resistance bank which can be
set to a maximum of 99.99GΩ with additional resistance values of 100kΩ, 200kΩ, 500kΩ, 1MΩ, 2MΩ and 5MΩ
which can be switched in as required.
The 5069 is constructed in the same style as Time Electronics’ well established 5080 PatCal but is suitable for
use up to 10kV.
5069 Technical Specifications
Resistance:
10GΩ, 1GΩ, 100MΩ, 10MΩ decade ranges.
Fixed Values:
5MΩ, 2MΩ, 1MΩ, 500KΩ, 200KΩ, 100KΩ.
Resistance accuracy:
100kΩ - 5MΩ, 1%. 10MΩ - 10GΩ, 1%. 10GΩ - 100GΩ, 5%.
Resistance temperature coefficient:
Less than 250ppm per °C
Open circuit voltage measure:
0 to 2kV range, accuracy 1% of FS
0 to 10kV range, accuracy 2% of FS.
Voltage display:
1.999kV full scale, and 10.00kV full scale
Short circuit current measure:
0 to 2mA range, 0 to 20mA range, both ranges 1% of f/s accuracy
Current display:
1.999mA full scale, and 19.99mA full scale
Power:
Internal battery, 6V re-chargeable NiCad, >150hrs between charges
General Specification
Dimensions:
W 16 x D 13 x H 7” (406W x 330D x 175H mm)
Weight:
9.7 lbs (4.4Kg)
Supplied with:
Safety connection plugs/leads with bare ends to allow custom fitted connectors
Mains battery re-charger
Ordering Information
Code
5069
9189
9112
Description
INSCAL Insulation Tester Calibration System
Factory Calibration Certificate
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
34
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
35
5070 DuctorCal
Time Electronics
Calibration, Test & Measurement
 Calibrate Ductor Testers and Micro-Ohm meters
 0.2, 2, 20, 200, 2000mΩ
 5 point calibration 0, 25, 50, 75, 100%
 Gold plated terminals
 Low thermal emf connection
 Portable robust carrying case
The 5070 DuctorCal is a portable instrument suitable for calibrating high current Ductor Testers and
Micro-Ohm meters. It contains 5 sets of high current standard resistors that are used for the calibration.
It has full 4 terminal capabilities with extra large terminals for the current connection. Gold plated terminals are
used throughout to reduce contact resistance and thermal emfs. It has a substantial maximum continuous
current rating, but can also be used with much higher transient/pulse test currents.
5070 Technical Specifications
Range
Current
Accuracy
50, 100, 150, 200uΩ
200A
0.8%
0.5, 1, 1.5, 2mΩ
100A
0.5%
5, 10, 15, 20mΩ
30A
0.2%
50, 100, 150, 200mΩ
10A
0.1%
0.5, 1, 1.5, 2Ω
3A
0.1%
The currents shown are the continuous rated currents for both AC and DC.
Higher currents (as generated by pulse driven instruments) can be used, and with an ON to OFF time ratio of
1:10 or less the allowed peak currents are 10 times those specified above, with an upper limit of 1000A.
However, in this case it is important to ensure there are adequate low resistance connections to the
DuctorCal’s current terminals.
General Specification
Dimensions:
Weight:
Accessories:
21 x 16 x 8” (54 x 41 x 21cm)
24.3 lbs (11Kg)
Calibration Certificates
Ordering Information
Code
5070
9146
9107
Description
DuctorCal
FactoryCalibration Certificate
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
35
36
5080 PatCal 2 - Calibrator for PATs
Time Electronics
Calibration, Test & Measurement

Suitable for traceable calibration of PATs and
VDE 0701 testers

Impact resistant case to IEC1010

Battery powered – ensures isolation and
prevents inaccuracies due to stray leakage

Voltage and Current displayed on integral LCD
digital meter

Safety interlock prevents contact with Earth
Bond studs during Insulation and Leakage tests

Earth Bond currents up to 50A AC can be
accurately measured

Load Test currents up to 13A AC can be
accurately measured
PAT-Cal2 is designed to provide rapid high accuracy calibration of PATs (Portable Appliance Testers) and
Insulation / Continuity Testers. All in one unit, it contains calibration functions for Earth Bond, Insulation,
Leakage, Touch Leakage and Load Test.
5080 Technical Specifications
EARTH BOND - Calibrated low value resistive loads
20mΩ, 5%. 190mΩ, 210mΩ, 950mΩ, 1.050mΩ, 1.08Ω, 2Ω, 10Ω, 18Ω, 1%
Open circuit voltage measurement: Range 0 – 20V accuracy 0.25% of full scale
High current AC measurement:
Range 0 – 50A AC accuracy 0.5% of reading +/- 0.2A
Low current AC measurement:
Range 0 – 2A AC accuracy 0.5% of reading +/- 2mA
Low current DC measurement:
Range 0 – 2A DC accuracy 1% of reading +/- 2mA
INSULATION - Calibrated high value resistive loads
95kΩ, 105kΩ, 500kΩ, 950kΩ, 1.05MΩ, 5MΩ, 10MΩ accuracy 0.1%. 20MΩ, 50MΩ, 100MΩ accuracy 1.0%
Open circuit voltage measurement: Range 0 – 1kV DC accuracy 0.25% of full scale
Current measurement:
Range 0 – 20mA DC accuracy 0.25% of full scale
LEAKAGE - Resistive loads for leakage current
Nominal leakage currents at 230V AC of 0.5, 1, 2, 5, 10, 15mA
Mains voltage measurement:
Range 0 – 500V AC accuracy 0.25% of full scale
Leakage current measurement:
Range 0 – 20mA AC accuracy 0.25% of full scale
TOUCH LEAKAGE - Constant current source for touch leakage meters
Current:
1.9mA AC 50 +/-5 Hz, into 2K2 maximum load resistance
Current measurement:
0 – 2mA AC, accuracy 0.25% of full scale
LOAD TEST - Connection of external load via a IEC connector
Mains voltage measurement:
Range 0 – 500V AC accuracy 0.25% of full scale
Load current measurement:
Range 0 – 13A AC accuracy 0.5% of full scale
General Specification
Dimensions:
W 16 x H 7 x D 13” (406W x 175H x 330D mm).
Weight:
12 lbs (5.5Kg)
Power:
Internal battery 6V re-chargeable NiCad, >200 hrs between charges.
Ordering Information
Code
Description
5080
PatCal 2 - Calibrator for PATs
9188
Factory Calibration Certificate
9135
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
36
Tel: 516-723-9909
PORTABLE TEST INSTRUMENTS
Email: [email protected]
37
Decade Boxes
Time Electronics manufacture a complete range of Decade Boxes, designed for
resistance, capacitance, and inductance. These precision instruments cover the
requirements of both field and laboratory work. They are high performance, delivering
accuracy, stability, and ease of use for applications.
RESISTANCE
1040 Resistance Box (1Ω - 100MΩ) ................................................................................................... 38
1041 Resistance Box Low Ohm (0.01Ω - 1kΩ) .................................................................................. 39
1051 Resistance Box Low Ohm (0.01Ω - 1MΩ) ................................................................................. 40
1061 Resistance Box Low Cost (1Ω - 1.2MΩ) .................................................................................... 41
1065 Resistance Box - Power 10W (0.1Ω - 100kΩ) ............................................................................ 42
1067 Resistance Box Precision Low Ohm (10mΩ - 12kΩ) ................................................................. 43
1049 Handheld PT100 Simulator Handheld (Class A °C) ................................................................... 44
1050 Handheld PT100 Simulator Handheld (Class A °F) ................................................................... 45
5011 Benchtop Programmable Resistance (1Ω - 120MΩ) .................................................................. 46
9820 Benchtop Programmable Resistance Low Ohm (0.1Ω - 100kΩ) ............................................... 48
CAPACITANCE
1070 Capacitance Box (100pF - 10uF) ............................................................................................... 50
1071 Capacitance Box (10pF - 100uF) ............................................................................................... 51
INDUCTANCE
1053 Inductance Box (1mH - 10H) ...................................................................................................... 52
Also see:
Resistance Measurement - 5068 InsCal (100kΩ - 10GΩ) and 5069 InsCal (100kΩ - 100GΩ) on pages 33 & 34.
Multifunction Calibrators with Resistance/Capacitance/Inductance capabilities on page 67.
www.timeeusa.com
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
37
38
1040 Decade Resistance Box
Time Electronics
Calibration, Test & Measurement






1  – 100 M
High accuracy
Clear visual indication
High stability
Low temperature coefficient
Removable Protective Boot
The 1040 is an accurate hand held decade resistance box designed to meet the needs of industry and
education. Housed in a robust metal case the compact construction makes it easily portable.
Excellent accuracy is achieved by using high stability metal film resistors. Mid-scale accuracy is 0.1%. The 8digit thumbwheel switch enables precise setting with a clear unambiguous indication of the resistance value.
The temperature coefficient is better than 50 ppm per ºC. Each resistor has a power rating of 1 watt.
Switch Contacts: Special attention has been given to reliability. A special multiple gold contact switch
arrangement ensures that back-up contacts are always available to take over should a contact fail.
Safety Terminals: Fully compatible with 4mm shrouded plugs, as well as standard plugs, bare wires, and
spade terminals.
Clear Visual Indication: To prevent misreading, the 1040 incorporates a colour coding system to divide the
display into 3 groups to indicate ohms, Kilohms, and Megohms.
Added Protection: The 1040 comes fitted with an ergonomic rubber boot (9028) providing increased
protection and durability. The boot has a textured grip for comfortable handling and a raised edge so the 1040
angles slightly upward when resting horizontally. This improves visibility as well as gripping the surface,
meaning no movement when thumbwheel switches are pressed. It is easily removable if required.
1040 Technical Specifications
Range: 1 to 100M in 1steps
Decade (
1 – 9
10 – 90 100 – 900 1 – 9k 10 – 90k 100 – 900k 1 – 9M 10 – 90M
Acc. %
± 1%
± 0.5%
± 0.1%
± 0.1%
± 0.1%
± 0.1%
± 0.1%
± 1%
Max Current (A)
0.5A
0.3A
100mA
30mA
3mA
0.3mA
30uA
3uA
Power Rating:
Voltage Rating:
1 watt per resistor. Metal film resistors.
Max 250V DC/AC (RMS)
Zero Residual:
Temp Coefficient:
Connections:
Less than 250m.
Less than 50 ppm per ºC.
4mm insulated terminal & binding post.
General Specification
Dimensions:
Weight:
Supplied with:
Optional Extras:
4.5 x 4 x 8” (110 x 75 x 200 mm)
1.3lb (0.6kg)
2 year warranty, test leads, protective rubber boot, factory calibration certificate.
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
1040
9026
9114
Description
Decade Resistance Box
Leatherette Carry Case
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
38
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
39
1041 Low Ohm Resistance Box
Time Electronics
Calibration, Test & Measurement





0.01 to 1k
10m resolution
High stability
Low temperature coefficient
Ideal for RTD/PRT
The 1041 is a compact, robust, and accurate decade resistance box designed for applications in both industry
and education. With its low resistance ranges the 1041 is particularly suitable for simulation of platinum
resistance thermometers.
Switch Contacts: Special attention has been given to the reliability of operation. A special multiple gold
contact arrangement ensures low contact resistance and continued operation even if a contact fails.
Safety Terminals: Fully compatible with 4mm shrouded plugs, as well as standard plugs, bare wires, and
spade terminals.
Added Protection: The 1041 comes fitted with an ergonomic rubber boot (9028) providing increased
protection and durability. The boot has a textured grip for comfortable handling and a raised edge so the 1041
angles slightly upward when resting horizontally. This improves visibility as well as gripping the surface,
meaning no movement when thumbwheel switches are pressed. It is easy to remove if the user prefers a
stand-alone unit or to house the decade box in the 9026 carry case.
1041 Technical Specifications
Range: 0.01 to 1k in 0.01 steps
Decade (
0.01
0.1
1
10
100
Acc. %
± 10
±5
±1
± 0.5
± 0.1
Zero Residual Resistance:
60m maximum
Residual Resistance Stability: less than 3 milliohms
Power Rating:
1 watt per resistor
Maximum Working Voltage:
100 volts DC, 70 volts AC (RMS)
Maximum Current:
1 amp DC, 0.7 amp AC (RMS)
Connection:
4mm terminals. A third terminal is provided to enable the case to be earthed
or connected to either terminal.
Temperature Coefficient:
100 ppm per °C
General Specification
Dimensions:
Weight:
Supplied with:
Optional Extras:
4.5 x 4 x 8” (110 x 75 x 200 mm)
1.3lb (0.6kg)
2 year warranty, test leads, protective rubber boot, factory calibration certificate.
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
1041
9026
9114
Description
Low Ohm Resistance Box
Leatherette Carry Case
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
39
40
1051 Low Ohm Resistance Box
Time Electronics
Calibration, Test & Measurement







0.01  – 1 M
High accuracy
Clear visual indication
High stability
Low temperature coefficient
Ideal for RTD/PRT
Removable protective boot
The 1051 is a wide range low ohm resistance box designed for general laboratory work including platinum
resistance thermometry.
Switch Contacts: Special attention has been given to the reliability of operation. A special multiple gold
contact arrangement ensures low contact resistance and continued operation even if a contact fails.
Safety Terminals: Fully compatible with 4mm shrouded plugs, as well as standard plugs, bare wires, and
spade terminals.
Clear Visual Indication: To enhance reading the setting, the 1051 has colour coded digits as shown in the
above image; Kohms (red), ohms (white), and 0.1 ohms (yellow).
Added Protection: The 1051 comes fitted with an ergonomic rubber boot (9028) providing increased
protection and durability. The boot has a textured grip for comfortable handling and a raised edge so the 1051
angles slightly upward when resting horizontally. This improves visibility as well as gripping the surface,
meaning no movement when thumbwheel switches are pressed. It is easy to remove if the user prefers a
stand-alone unit or to house the decade box in the 9026 carry case.
1051 Technical Specifications
Range: 0.01to 1M in 0.01steps
Decade (
0.01
0.1
1
10
100
1k
10k
100k
Acc. %
± 10%
± 5%
± 1%
± 0.5%
± 0.1%
± 0.1%
± 0.1%
± 0.1%
Max Current (A)
1A
1A
1A
0.3A
0.1A
33mA
10mA
3mA
Zero Residual Resistance:
Less than 90m
Residual Resistance Stability:
Maximum Voltage:
Power Rating:
Temperature Coefficient:
Less than 3 m
250V DC/AC RMS
1 watt per resistor
< 100 ppm per ºC
General Specification
Dimensions:
Weight:
Supplied with:
Optional Extras:
4.5 x 4 x 8” (110 x 75 x 200 mm)
1.3lb (0.6kg)
2 year warranty, test leads, protective rubber boot, factory calibration certificate.
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
1051
9026
9114
Description
Decade Resistance Box
Leatherette Carry Case
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
40
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
41
1061 Low Cost Resistance Box
Time Electronics
Calibration, Test & Measurement

1 to 1.2M

In-line read-out

Stable metal film resistors

Mechanically and electrically robust

Fully Screened

Safety Terminals
The 1061 Decade Resistance Box is designed to meet the standard required in both educational and industrial
applications. Metal film resistors, with the advantages of stability and low temperature coefficient, are used
throughout. The case provides complete electrostatic screening.
Six large switches with a clear numerical readout make the resistance boxes easy to use in educational
establishments or in other applications where robustness is a price consideration. The slim line design uses
minimum bench space, while the 1% accuracy and wide range makes it ideal for production or select-on-test
uses.
The 1061 is housed in a robust all-metal case, finished in two-tone blue and black. The front panel safety
terminals are compatible with 4mm shrouded plugs, as well as standard plugs, bare wires, and spade
terminals.
1061 Technical Specifications
Resistance Range:
1 to 1.2M
Number of Decades:
6
Increment:
1 steps
Accuracy:
± 1%
Rating:
All resistors rated 0.75W
Terminations:
Resistance – 4 mm red & black
Chassis – 4 mm Green
Residual Resistance:
Less than 150 m
General Specification
Dimensions:
3 x 2.5 x 14” (80 x 63 x 355mm)
Weight:
1.7lbs
Supplied with:
2 year warranty, test leads, and factory certificate
Optional Extras:
UKAS/NIST Traceable Calibration Certificate
(0.75kg)
Ordering Information
Code
1061
9114
Description
Low Cost Resistance Box
UKAS/NIST Traceable Calibration Certificate
www.timeelectronics.com
Tel: +44 (0)1732 355993
DECADE BOXES
Email: [email protected]
41
42
1065 Precision Power Resistance Box
Time Electronics
Calibration, Test & Measurement

0.1 to 120k

1% Accuracy

10W per resistor dissipation

In-line read-out

Mechanically and electrically robust

Fully Screened
The 1065 Power Decade Resistance Box is designed to meet the standard for educational, industrial and
research & design applications. Housed in a well ventilated metal case its compact construction makes it easily
transportable, and when in use it takes up a minimum of bench space.
Resistance ranges from 0.1 to 120k with a 1% accuracy. Each resistor has a power rating of 10W and the
maximum working voltage is 500V.
Switch contact resistance has been kept to a minimum by the use of multi-wafer switches, each with four
parallel, silver-plated, self-wiping contacts. The six in-line dials give a clear numerical readout of the selected
resistance.
1065 Technical Specifications
Resistance Range:
0.1 to 120 k
No. Of Decades:
6
Increment:
0.1 steps
Accuracy:
0.1 decade, ±5%
1120k decades, ±1%
Rating:
Each resistor 10W
Temperature Coefficient:
<200 ppm per °C
Maximum Voltage:
500 V AC/DC
Residual Resistance:
<20m
General Specification
Dimensions:
15 x 2.3 x 7” (390 x 60 x 150mm)
Weight:
4.5lbs (2kg)
Supplied with:
2 year warranty, test leads, and factory calibration certificate
Optional Extras:
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
1065
9114
Description
Power Resistance Box
UKAS/NIST Traceable Calibration Certificate
www.timeeusa.com
42
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
43
1067 Precision Decade Resistance Box
Time Electronics
Calibration, Test & Measurement

Precision PT100 Simulation

0.01% Accuracy

10m – 12k

6 Digit Resolution

Better than 20ppm/year stability
The 1067 precision decade resistance box is suitable for a wide range of simulation work. It is particularly
suitable for simulating and calibrating precision PT100 sensors and temperature indicators/meters that use
resistive sensors.
Special care has been taken in the construction of the 1067 to ensure that the residual end resistance is as low
and as stable as possible. Multiple self-wiping silver alloy contacts are used for each position to ensure
outstanding performance and long life.
Housed in a robust metal case the 1067 is fully screened and low thermal emf terminals are used.
The switch dials have clear markings and in an easy to read in-line format. Each decade is scaled from 0 to 11
and therefore allows convenient overlap of the set values. The maximum value settable is 12,222.21 ohms.
1067 Technical Specifications
Resistance range:
10m to 12k
Number of decades:
6, each decade settable from 0 – 11
Increments:
10m steps
Accuracy:
At calibration temperature of 22 °C. +/- 0.01% of setting +/- 2m, after
deduction of residual end resistance +/- 1m for residual variation.
Current rating:
10m range: 3A, 100m range: 2A, 1 range: 600mA
10 range: 200mA, 100 range: 60mA, 1k range: 20mA
Residual end resistance:
Less than 10m. Less than 1m variation
Temperature coefficient:
Less than 10 ppm per °C (> 1). Less than 20 ppm per °C (< 1)
Maximum voltage:
200V at maximum resistance setting
Insulation:
Case to resistance terminals 2kV / 50Hz max
Operating torque:
Less than 0.1 Nm
Stability:
Better than 20 ppm per year (>1) Better than 100 ppm per year (<1)
Contacts:
Make before break – Silver alloy
General Specification
Dimensions:
3.5 x 2.5 x 14” (87 x 63 x 355mm)
Weight:
2.4lbs (1.1kg)
Supplied with:
2 year warranty, test leads, and factory certificate
Optional Extras:
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
1067
9114
Description
Precision Decade Resistance Box
UKAS/NIST Traceable Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
43
44
1049 Class A °C PT100 Simulator
Time Electronics
Calibration, Test & Measurement

-200°C to + 800°C

± 0.3°C accuracy

Based on ITS 90 EN60751

23 set points

Exceeds Class A

Good temperature stability

Passive resistance source
The 1049 is a portable precision simulator for PT100 0.3850 platinum resistance elements used for accurate
temperature measurement.
It follows the PT100 scale from –200°C to +800°C with 23 set points. High performance metal film resistors are
used throughout which ensures a good temperature coefficient and long term stability.
The specification is in accordance with DIN EN 60751 (ITS 90). Offering high accuracy across the full operating
range of PT100 devices it exceeds the performance of Class A & B. The 1049 will be of particular interest to
those operating in the –60 to +60°C range where a performance exceeding Class A (e.g. better than +/- 0.15°C
at 0°C), is required.
Since the 1049’s output is a purely passive resistance it will operate with all types of PT100 measuring
equipment including the live systems using pulsed, or interrupted excitation current.
1049 Technical Specifications
Set points °C:
-200, -100, -50, -20, -10, 0, 10, 20, 30, 40, 50, 60, 80,
100, 150, 200, 250, 300, 400, 500, 600, 700, 800.
Accuracy:
-200 to -100°C ± 0.3°C
-50 to +60°C ± 0.15°C
+80 to +200°C ± 0.3°C
+250 to +500°C +/- 0.5°C
+600 to +800°C +/- 0.65°C
Temp Coefficient:
Less than 30 ppm per °C
Maximum Current:
50 mA
General Specification
Dimensions:
2.4 x 5 x 2.2“ (61 x 112 x 55 mm)
Weight:
0.4lb (170g)
Supplied with:
2 year warranty, test leads, factory certificate, and leather carry pouch
Optional Extras:
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
1049
9114
Description
Handheld PT100 °C Simulator
UKAS/NIST Traceable Calibration Certificate
www.timeeusa.com
44
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
45
1050 Class A °F PT100 Simulator
Time Electronics
Calibration, Test & Measurement

-100°F to 1000°F

± 0.5°F accuracy

Based on ITS 90 EN60751

23 set points

Exceeds Class A

Good temperature stability

Passive resistance source
The 1050 is a precision simulator for PT100 0.3850 Platinum Resistance elements used for accurate
temperature measurement.
It follows the PT100 scale from –100°F to +1000°F with 23 set points. High performance metal film resistors are
used throughout which ensures a good temperature coefficient and long term stability.
The specification is in accordance with DIN EN 60751 (ITS90). Offering high accuracy across the full operating
range of PT100 devices it exceeds the performance of Class A & B. The 1050 will be of particular interest to
those operating in the –80 to +140°F range where performance exceeding Class A e.g. better than +/- 0.3°F at
32°F, is required.
Since the 1050’s output is a purely passive resistance it will operate with all types of PT100 measuring
equipment including the live systems using pulsed, or interrupted excitation current.
1050 Technical Specifications
Set points °F:
-100, -50, -25, 0, 32.2, 50, 75, 100, 125, 150, 175, 200,
225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 1000
Accuracy:
-100 to 300 °F +/- 0.5 °F
300 to 1000 °F +/- 0.9 °F
Temp Coefficient:
Less than 25 ppm per °F
Maximum Current:
50 mA
General Specification
Dimensions:
2.4 x 5 x 2.2“ (61 x 112 x 55 mm)
Weight:
0.4lb (170g)
Supplied with:
2 year warranty, test leads, factory certificate, and leather carry pouch
Optional Extras:
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
1050
9114
Description
Handheld PT100 °F Simulator
UKAS/NIST Traceable Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
45
46
5011 Resistance / Temperature Calibrator
Time Electronics
Calibration, Test & Measurement

1  to 120 M

RTD Simulation

Thermocouple Simulation

DCV & DCI Options

10MHz Frequency Option

RS232/GPIB/USB

Front Panel Operation
The 5011 is primarily a programmable resistance / RTD source. With the ability to add DC Voltage,
Thermocouple Simulation and DC Current the 5011 is truly a versatile temperature calibrator.
High performance resistance of is offered as standard with an accuracy of 0.01% and 1mΩ resolution
from 50Ω to 1kΩ.
Simple front panel operation allows the user to quickly set the function and output required.
Using the jog / shuttle dial deviation the user can finely adjust the output value as a percentage (+/9.99%). All this information is shown on a clear, easy to read LED display.
As standard the 5011 uses a SCPI command structure for programming. The 5011 also supports the
older 9811/19/20 command set making it an ideal replacement for these models.
The DCV / Thermocouple option provides a DC voltage source (+/- 20V) and simulates thermocouple
types K, J, T, R, S, N, E and B.
A DC Current option is available which sources up to 220mA. This makes the 5011 ideal for accurate
process control calibration.
A 0.1 Hz to 10 MHz frequency (Period 100nS to 10s) option is also available. The output is variable
with a best resolution setting of 0.1Hz.
Calibration Made Easy
Connect the 5011 to a PC/Laptop (via RS232, GPIB or USB) installed with Time Electronics EasyCal
and automate the calibration process. Increase speed of calibration and consistency of results;
produce calibration certificates and reports to ISO 9001 quality standards.
www.timeeusa.com
46
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
47
5011 Technical Specifications
Accuracies quoted are for 1 year.
THERMOCOUPLE SIMULATION
RESISTANCE
Range
Accuracy
Resolution
Type
Range ºC
Acc. ºC
-210 to 150 / 150 to 1200
0.15 / 0.3
1Ω – 20Ω
0.01% +/- 5mΩ
1Ω
J
20Ω – 99.999Ω
0.01% +/- 5mΩ
1mΩ/5mΩ*
K
-270 to 190 / 190 to 1250
0.5 / 0.6
1mΩ
T
-200 to 150 / 150 to 400
0.4 / 0.5
-50 to 800 / 800 to 1750
0.8 / 2.0
100Ω – 999.999Ω
0.01% +/- 5mΩ
1kΩ – 9.999kΩ
0.02% +/- 20mΩ
1Ω
R
10kΩ – 99.999kΩ
0.01% +/- 1Ω
1Ω
S
-50 to 850 / 850 to 1750
0.9 / 2.0
B
100 to 1200 / 1200 to 1800
1.0 / 2.0
N
-270 to 260 / 260 to 1300
0.5 / 0.4
E
-50 to 1000
0.3
100kΩ – 999.99kΩ
0.01% +/- 10Ω
10Ω
1MΩ – 9.9999MΩ
0.02% +/- 100Ω
100Ω
10MΩ – 120MΩ
0.1% +/- 1kΩ
1kΩ
Temp Coefficient:
Power Rating:
Maximum Voltage:
Resistance Switch Time:
Operation Time:
End Resistance Variation:
Cold Junction Compensation +/- 0.5ºC (applies to ambient
changes of less than +/- 1ºC at 23 ºC)
less than 50 ppm per ºC
0.1 Watt per resistor
250 V
< 250us
< 300ms
< 2.5mΩ
The accuracy of the thermocouple simulation is determined by the
accuracy of the 5011’s DC Voltage function and the accuracy of
the standard thermocouple tables (BS EN 60584-1) published by
the British Standards Institute.
The 5011 uses precise digital interpretation of the tables to output
voltage levels that are within the accuracies specified in the table.
*Output Setting Resolution below 50Ω is 5mΩ
DC VOLTAGE
PRT SIMULATION
RTD Type
Alpha Coeff
Range
Accuracy
Pt100
0.003850
-180 to -100ºC
0.1ºC
Pt100
0.003850
-100 to 850ºC
0.05ºC
It should be noted that the accuracy of the PRT simulation is
determined by the accuracy of the PRT tables (BS EN 60751)
published by the British Standards Institute. The 5011 uses precise
digital interpretation of the tables to output resistance values that are
within the accuracies specified in the table.
Range
Accuracy
Resolution
20mV
100ppm + 4uV
100nV
200mV
30ppm + 6uV
1uV
2V
25ppm + 20uV
1uV
20V
25ppm + 150uV
10uV
DC CURRENT (Compliance Voltage: 11V)
Range
220uA
2.2mA
22mA
220mA
FREQUENCY / PERIOD (2V pk/pk approx)
0.1Hz to 10MHz / 100nS to 10s Accuracy 20ppm
Accuracy
150ppm + 15nA
100ppm + 40nA
80ppm + 200nA
80ppm + 3uA
Resolution
1 nA
10 nA
10 nA
100 nA
General Specification
Power:
110 V to 240 V AC 50/60 Hz. 30 VA
Operating Temperatures:
0-45 ºC. 22 ºC +/- 3 ºC for full specification.
Dimensions:
Weight:
Optional Extras:
W 18 x D 11 x H 7 “ (W 450 x D 272 x H 152 mm).
15.4lbs (7 Kg)
DC Voltage and Thermocouple Simulation, DC Current, 10MHz Frequency.
Factory or UKAS/NIST Calibration Certificates
Rack Mount Kit
Ordering Information
Code
Description
5011
Resistance / Temperature Calibrator
9711
DC Voltage and Thermocouple Simulation
9718
DC Current 220mA (Only available if 9711 DC Voltage option fitted)
9729
Frequency Option (10MHz digital)
9728
Rack Mount Kit
9115
UKAS/NIST Calibration Certificate (ISO 17025)
9171
Factory Calibration Certificate
9747
EasyCal Calibration Software
www.timeeusa.com
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
47
48
9820 Programmable Low Ohm Resistance
Time Electronics
Calibration, Test & Measurement

0.1Ω to 100kΩ

0.01% Basic Accuracy

Platinum Resistance
Thermometer Simulation

GPIB/SERIAL interface

Bench Case supplied as standard
The 9820 has been designed for applications where programmable low value resistance is
required such as platinum resistance thermometry.
Each decade is brought out on separate terminals allowing the resistance to be separated
into decades and can be used independently if required and precision ratio dividers set up.
The full local control is particularly useful at system design stage and for checking and
troubleshooting.
Construction is standard 19” 3U Euro-frame with plug-in modules which allow easy access
and improved servicing/maintenance. The unit can be rack mounted or housed in a free
standing case.
Programming
The resistance value is set by sending up to 6 numeric digits via the remote interface, either
GPIB or RS232 Serial. The least significant digit sets the lowest decade and the most
significant digit sets the highest decade. Less than 6 digits can be sent if it is not required to
set all decades.
The unit can be sent into local control mode via the remote interface. The setting of the front
panel digits switches can then be read back over the bus. The Group Execute Trigger
Command (GET) is also supported.
www.timeeusa.com
48
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
49
9820 Technical Specifications
RESISTANCE SPECIFICATION
Resistance Range:
0.1Ω to 100kΩ
Resistance Output
Output is on 6 pairs of rear panel 4 mm terminals which divide the resistance into
6 independent decades
Accuracy:
0.1Ω
1Ω
10Ω
100Ω
1kΩ
10kΩ
± 5%
± 0.5%
±0.05%
± 0.01%
± 0.01%
± 0.01%
General Specification
Residual Resistance:
< 10 mΩ / decade
Temp. Coefficient:
less than 50 ppm/ºC
Power Rating:
1 watt max per decade
Maximum Current:
1 Amp (1 watt max)
Maximum Voltage:
100 Volts
Operation Time:
50 ms
Operating Life:
30 million operations
Thermal Emfs: <2uV. The internally generated emfs
have been kept to a minimum using
special techniques.
Relay Contacts:
Special attention has been
given to the problem of
reliability. Double pole gold
contacts have been used.
Remote Interface:
GPIB (IEEE488) or RS232
Device Address:
Rear panel switch 0 – 31
Bus Connection:
Standard 24 pin GPIB
connector and standard
serial 9 pin DIN.
Power:
110V/120V/220V/240V AC
50/60 Hz
Operating Temp:
0 – 40 ºC
Dimensions:
19 x 15 x 6” (480 x 374 x 154 mm) Rack Mount Version
20 x 7 x 12” (520 x 170 x 315 mm) Bench Version
Weight:
13 lbs (6 kg) Rack Mount Version
24 lbs (11 kg) Bench Version
Supplied with:
Bench Case (9047)
Optional Extras:
NPL Traceable Calibration Certificate
UKAS Calibration Certificate
Ordering Information
Code
Description
9820
Low Ohm Resistance 0.1Ω to 100kΩ
9163
Factory (NPL Traceable) Calibration Certificate
9120
UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
49
50
1070 Decade Capacitance Box
Time Electronics
Calibration, Test & Measurement







100 pF to 10 µF
1% Accuracy
In-line read-out
Colour coded digits
Bi-polar working
Safety terminals
Removable protective boot
High accuracy and wide range makes the 1070 capacitance box suitable for many applications in industry and
education. It is housed in a metal case to provide complete screening and a residual capacitance of
approximately 40pF.
Safety Terminals: Fully compatible with 4mm shrouded plugs, as well as standard plugs, bare wires, and
spade terminals.
Clear Visual Indication: To enhance reading the setting, the 1070 has colour coded digits as shown in the
above image; µF (red), ηF (white), and pF (yellow).
Added Protection: The 1070 comes fitted with an ergonomic rubber boot (9028) providing increased
protection and durability. The boot has a textured grip for comfortable handling and a raised edge so the 1070
angles slightly upward when resting horizontally. This improves visibility as well as gripping the surface,
meaning no movement when thumbwheel switches are pressed. It is easy to remove if the user prefers a
stand-alone unit or to house the decade box in the 9026 carry case.
1070 Technical Specifications
RANGE
TYPE
ACCURACY
@ 1kHz
MAX VOLTAGE
TEMP COEFF
ppm/°C max
POWER
FACTOR
@ 1kHz
INSULATION
RESISTANCE
9 x 100pF
Silver mica
1% ± 5pF
300V dc 200V ac
200
< 0.0015
> 50G
9 x 1nF
Silver mica
1% ± 5pF
300V dc 200V ac
50
< 0.002
> 50G
9 x 10nF
Silver mica
1%
100V dc 72V ac
50
< 0.01
> 30G
9 x 100nF
Polycarbonate
1%
100V dc 72V ac
75
< 0.01
> 30G
9 x 1µF
Polycarbonate
1%
100V dc 115V ac
75
< 0.01
> 30G
General Specification
Dimensions:
4.5 x 4 x 8” (110 x 75 x 200 mm)
Weight:
1.3lb (0.6kg)
Supplied with:
2 year warranty, test leads, protective rubber boot, factory certificate, and carry case
Optional Extras:
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
Description
1070
Decade Capacitance Box
9114
UKAS/NIST Traceable Calibration Certificate
www.timeeusa.com
50
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
51
1071 Decade Capacitance Box
Time Electronics
Calibration, Test & Measurement







10 pF to 100 µF
1% Accuracy
In-line read-out
Colour coded digits
Bi-polar working
Safety terminals
Removable protective boot
High accuracy and wide range makes the 1071 capacitance box suitable for many applications in industry and
education. It is housed in a metal case to provide complete screening and a residual capacitance of
approximately 55pF.
Safety Terminals: Fully compatible with 4mm shrouded plugs, as well as standard plugs, bare wires, and
spade terminals.
Clear Visual Indication: To enhance reading the setting, the 1071 has colour coded digits as shown in the
above image; µF (red), ηF (white), and pF (yellow).
Added Protection: The 1071 comes fitted with an ergonomic rubber boot (9028) providing increased
protection and durability. The boot has a textured grip for comfortable handling and a raised edge so the 1071
angles slightly upward when resting horizontally. This improves visibility as well as gripping the surface,
meaning no movement when thumbwheel switches are pressed. It is easy to remove if the user prefers a
stand-alone unit or to house the decade box in the 9026 carry case.
1071 Technical Specifications
RANGE
TYPE
ACCURACY
@ 1kHz
MAX VOLTAGE
TEMP COEFF
ppm/°C max
POWER
FACTOR
@ 1kHz
INSULATION
RESISTANCE
9 x 10pF
Silver mica
1% ± 5pF
300V dc 200V ac
200
< 0.0025
> 50G
9 x 100pF
Silver mica
1% ± 5pF
300V dc 200V ac
200
< 0.0015
> 50G
9 x 1nF
Silver mica
1% ±5pF
300V dc 200V ac
50
< 0.002
> 50G
9 x 10nF
Silver mica
1%
100V dc 72V ac
50
< 0.01
> 30G
9 x 100nF
Polycarbonate
1%
100V dc 72V ac
75
< 0.01
> 30G
9 x 1µF
Polycarbonate
1%
100V dc 115V ac
75
< 0.01
> 30G
9 x 10µF
Polyester
5%
63V dc 50V ac
300
< 0.01
> 30G
General Specification
Dimensions:
4.5 x 4 x 8” (110 x 75 x 200 mm)
Weight:
1.3lb (0.6kg)
Supplied with:
2 year warranty, test leads, protective rubber boot, factory certificate, and carry case
Optional Extras:
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
Description
1071
9114
Decade Capacitance Box
UKAS/NIST Traceable Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
51
52
1053 Decade Inductance Box
Time Electronics
Calibration, Test & Measurement

1 mH to 10 H

In-line read-out

3% Accuracy

High stability

Compact: 25 x 6 x 10 cm

Fully Screened

Safety Terminals
The 1053 is a compact, robust and accurate decade inductance box suitable for filter design, experimental,
general purpose substitution, and DC to DC converter design.
Inductance is set by four easy-to-read dials that are divided into 4 decades, and provide 1mH, 10mH, 100mH,
and 1H steps. The maximum setting is 11.11H.
Its custom wound, high permeability ferrite cores ensure insignificant influence from external magnetic fields
and maximum stability.
The 1053 is housed in a fully screened robust metal case. The front panel safety terminals are compatible with
4mm shrouded plugs, as well as standard plugs, bare wires, and spade terminals.
1053 Technical Specifications
Inductance Range:
1mH to 10H (4 decades)
Accuracy at 1kHz:
3% of setting
End Resistance:
Less than 0.2Ω
End Inductance:
Less than 1uH
Max current per decade:
30mA (1mH), 70mA (10mH), 100mA (100mH), 150mA (1H)
Average resistance per step:
0.1Ω (1mH), 0.5Ω (10mH), 3.4Ω( 100mH), 20.5Ω (1H)
Typical Q Factor at 1kHz:
75 (1mH), 175 (10mH), 280 (100mH), 250 (1H)
Max. Voltage:
30V AC rms (non-switching). Subject to max current rating.
General Specification
Dimensions:
10 x 2.5 x 4” (245 x 62 x 100mm)
Weight:
1.8lbs (0.8kg)
Supplied with:
2 year warranty, test leads, and factory calibration certificate
Optional Extras:
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
1053
9170
9114
Description
Decade Inductance Box
Factory (NPL Traceable) Calibration Certificate
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
52
Tel: 516-723-9909
DECADE BOXES
Email: [email protected]
53
Digital Multimeters & Power Calibrators/Sources
Time Electronics manufacture high accuracy and versatile digital multimeters, power
calibrators, and power sources. Units can be controlled via GPIB, RS232, and USB.
EasyCal calibration software can be used to automate the calibration process,
increase speed of calibration and consistency of results. A comprehensive suite of
programs offering over 1000 test procedures and networking capabilities. Users can
print and customise test certificates as required.
DMMS
5065 6.5 digit Bench Multimeter .......................................................................................................... 54
5075 Precision Digital Multimeter ........................................................................................................ 56
POWER CALIBRATORS AND SOURCES
5033 High Precision Programmable DC Power Source - 3 Channel .................................................. 60
5077 Power Calibrator (PowerCal)...................................................................................................... 62
9840 Series Power Calibrators (Single and 3 Phase) ......................................................................... 64
Also see:
5025 Multifunction Calibrator on page 76.
EasyCal Software on page 82.
www.timeeusa.com
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
53
54
5065 Bench Digital Multimeter
Time Electronics
Calibration, Test & Measurement

Resolution 6 1/2 digits

Accuracy: 0.005% DC Voltage

USB Interface

Optional GPIB Interface

Temperature Measurements

SCPI Command Set

10 Channel scanner interface available
The 5065 is a high performance, versatile 6 ½ digit bench multimeter with 19 measurement functions.
Low cost, simple operation, stability, and high accuracy make the 5065 an ideal DMM for a variety of
applications. In addition high speed means both the sampling rate and the data transfer rate can
achieve 2000 readings per second.
The comprehensive range of features makes the 5065 suitable for test engineers, R&D, service, and
calibration technicians. The durable construction with a protective rubber guard and carry handle
allows convenient bench top use, and transportability.
The front panel features a two-line, colour-coded display for easy to read measurements and
functions. Control is simple, with common functions selected from a single button press.
The 5065 measures AC/DC voltage, AC/DC current, 2/4 wire resistance, frequency, period, diode,
continuity, thermocouples and RTD.
In addition to standard functions many other capabilities such as Min/Max, Ratio/% and Null are
included. Memory functions with up to 2000 readings can be stored and recalled. Limit testing with an
external output can be configured to signal pass or fail.
The USB interface enables connectivity to a PC. A basic setup and graphing application is supplied
as standard. Add-in utilities for Microsoft Excel and Word allow simple data collection directly into a
spreadsheet or document.
An optional 10 channel scanner card is available which allows multiple inputs to be measured.
Further options are test lead sets, GPIB and RS232 interfaces, and an RTD probe adaptor.
Calibration Made Easy
Connect the 5065 to a PC/Laptop installed with Time Electronics EasyCal and automate the
calibration process. Increase speed of calibration and consistency of results, produce calibration
certificates and reports to ISO 9001 quality standards.
www.timeeusa.com
54
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
55
5065 Technical Specifications
Specifications are for 1 year ±(% of reading + % of range) (23 ºC ±5 ºC)
DC Voltage
Resolution
Input Resistance
0.1 uV
> 10GΩ
1.0 uV
> 10GΩ
10 uV
> 10GΩ
100 uV
10MΩ
1 uV
10MΩ
DC Current
Resolution
Shunt Resistance
10nA
5.1Ω
100nA
5.1Ω
1uA
0.1Ω
10uA
0.1Ω
Range
100.0000 mV
1.000000 V
10.00000 V
100.0000 V
1000.000 V
Range
10.000000mA
100.00000mA
1.000000A
3.00000A
Accuracy
0.0050 + 0.0035
0.0040 + 0.0007
0.0035 + 0.0005
0.0045 + 0.0006
0.0045 + 0.0010
Accuracy
0.05 + 0.02
0.05 + 0.005
0.1 + 0.01
0.12 + 0.02
Resistance
Range
100.0000 Ω
1.000000 KΩ
10.00000 KΩ
100.0000 KΩ
1.000000 MΩ
10.00000 MΩ
100.0000 MΩ
Diode Test
1.0000V
Continuity
1000.00KΩ
Resolution
100uΩ
1mΩ
10mΩ
100mΩ
1Ω
10Ω
100Ω
Test Current
1mA
1mA
100uA
10uA
5uA
500nA
500nA
Accuracy
0.01 + 0.004
0.01 + 0.001
0.01 + 0.001
0.01 + 0.001
0.01 + 0.001
0.04 + 0.001
0.8 + 0.01
10uV
1mA
0.01 + 0.02
1mA
0.01 + 0.03
Frequency (Hz)
3-5
5-10
10-20K
20-50K
50K – 100K
100K – 300K
3-5
5-10
10-20K
20-50K
50K – 100K
100K – 300K
Accuracy
1.00 + 0.04
0.35 + 0.04
0.06 + 0.04
0.12 + 0.05
0.60 + 0.08
4.00 + 0.50
1.00 + 0.03
0.35 + 0.03
0.06 + 0.03
0.12 + 0.05
0.60 + 0.08
4.00 + 0.50
Frequency (Hz)
3-5
1uA
5-10
10-5K
3-5
10uA
5-10
10-5K
Frequency and Period
Frequency (Hz)
3-5
5-10
10-40
40-300K
Accuracy
1.00 + 0.04
0.30 + 0.04
0.10 + 0.04
1.10 + 0.06
0.35 + 0.06
0.15 + 0.06
10mΩ
AC Voltage
Range
Resolution
100.0000mV
0.1uV
1.000000V to 750.000V
1.0 uV To 1mV
Range
Resolution
AC Current
1.000000A
3.000000
Range
100mV to 750V
Accuracy (% of reading )
0.1
0.05
0.03
0.06
RTD Types: PT100,D100, F100, PT385 or PT3916. (Best Acc. ±0.08°C )
Thermocouple Types: J,K & T(Acc. ±0.5°C ). E(Acc. ±0.6°C ).R,S & B(Acc. ±5°C )
General Specification
Dimensions:
Weight:
85(H) x 210(W) x 350(D)mm
4.36kg
Ordering Information
Code
5065
9714
9715
9716
9717
Description
6.5 Digit DMM
10 Channel Scanner Card
GPIB Interface
RS232 Interface
RTD Probe Adaptor
www.timeeusa.com
Code
9541
9796
9747
9173
9117
Description
5 piece Test Lead Set
12 piece Test Lead set
EasyCal Calibration Software
Factory Calibration Certificate
UKAS/NIST Calibration Certificate
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
55
56
5075 Precision Digital Multimeter
Time Electronics
Calibration, Test & Measurement

7 Digit Resolution

AC/DC Voltage & Current

Resistance

Capacitance & Frequency

18ppm / Year accuracy
The 5075 is a benchtop digital multimeter that combines high performance and accuracy with simple
operation.
With speed and precision, the 5075 easily measures from nanovolts to 10kV, from picoamps to 30
Amps, from micro-ohms up to 1GΩ, from picofarads to 300uF, with up to 7½ digit accuracy and a
price that is less than many 6½ digit multimeters.
The low level voltage, current and resistance ranges enables the 5075 to make measurements of
small signals without using the 6½ or 7½ digit resolution mode, which is often slow, noisy and
inaccurate. For example, with the 30mΩ range a 100nΩ resistance can be resolved using the 6½
digit resolution mode.
The Auto Dynamic Filter (ADF) mode allows the 5075 to automatically select the most suitable filter.
For a fast changing signal or for when the signal is first connected the reading is displayed almost
immediately, but if the input remains constant, the filter time is increased to provide a more stable
accurate reading. If the input were disconnected the filter would immediately return to the fastest.
Operation is simple, all major functions from range selection to null require just one key press. The
large 24 digit, custom vacuum fluorescent display shows clearly the range and reading and can even
show the time to the next sample if required. Other functions can be easily selected from a scrolled
menu.
Functions for diode/zener tests, max/min, peak hold and continuity checks are available and also
various audible warnings can be selected.
A bar graph function allows the user to program high and low pass/fail limits and switch to the bar
display mode. This will give an audible and visual indication to the user of the components
specification.
A low thermal, 10-channel scanner option, allows multiple inputs to be displayed or compared without
the additional cost and inconvenience of a separate switching arrangement.
Also available to complement the 5075 Precision DMM is EasyCal software. This will enable the user
to automate the calibration of voltage sources, current sources, decade boxes and frequency
sources.
www.timeeusa.com
56
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
57
5075 Technical Specifications
Accuracy Specifications
Accuracy specified as ± ppm reading + ± Floor at default resolution (shown in brackets), relative to calibration standards.
TCAL = 20°C
DC Voltage (All specifications ± 0.4uV)
RANGE
RESOLUTION
Resolution at
default
In brackets
90 DAY ±
5ºC
1 YEAR ± 5ºC
10nV (10nV)
22 + 80nV
30 + 80nV
10nV (100nV)
22 + 800nV
30 + 800nV
22 + 8uV
30 + 8uV
0 – 300uA
12 + 6uV
18 + 6uV
0 - 1mA
1µV (10uV)
12 + 60uV
18 + 60uV
10µV (100uV)
20 + 600uV
30 + 600uV
100µV (1mV)
22 + 8mV
30 + 8mV
1mV (10mV)
250 + 1V
350 + 1.2V
0 - 3mV
0 - 10mV
100nV (1uV)
0 - 3V
0 - 10V
10pA (10pA)
150 + 200pA
200 + 250pA
100pA
(100pA)
75 + 1nA
100 + 1nA
100pA (1nA)
75 + 10nA
100 + 10nA
1nA (10nA)
75 + 100nA
100 + 100nA
10nA (100nA)
75 + 1uA
100 + 1uA
100nA (1uA)
150 + 10uA
200 + 10uA
10uA (10uA)
500 + 200uA
750 + 200uA
100uA(100uA)
500 + 2mA
750 + 2mA
0 – 10uA
0 – 100uA
0 - 10mA
0 - 100mA
0 - 300mA
0 - 1A
0 - 3kV
0 - 10kV
1 YEAR ± 5ºC
0 - 30mA
0 - 300V
0 - 1kV
90 DAY ±
5ºC
0 - 3mA
0 - 30V
0 - 100V
RESOLUTION
Resolution at
default
In brackets
0 – 30uA
0 - 300mV
0 - 1V
RANGE
0 – 3uA
0 - 30mV
0 - 100mV
DC Current
0 - 3A
0 - 10A
0 - 30A
Resistance
Two wire ranges begin at 300mΩ
Accuracy applies to 2 and 4 wire resistances.
RANGE
RESOLUTION
Resolution at 90 DAY ±5
default
ºC
In brackets
1 YEAR ± 5ºC
0 - 30mΩ
0 - 100mΩ
70 + 2uΩ
100 + 2.5uΩ
100nΩ (1uΩ)
40 + 10uΩ
60 + 15uΩ
1uΩ (10uΩ)
30 + 80uΩ
40 + 100uΩ
10uΩ (100uΩ)
20 + 600uΩ
30 + 800uΩ
10mΩ
(100mΩ)
30 + 600mΩ
45 + 800mΩ
100mΩ (1Ω)
60 + 8Ω
90 + 10Ω
1Ω (10Ω)
100 + 100Ω
150 + 120Ω
100Ω (100Ω)
750 + 10kΩ
1000 + 10kΩ
100uΩ (1mΩ)
20 + 6mΩ
30 + 8mΩ
10kΩ (10kΩ)
0.5% + 1MΩ 0.75% + 1MΩ
1mΩ (10mΩ)
20 + 60mΩ
30 + 80mΩ
0 - 100kΩ
0 - 1MΩ
0 - 10MΩ
0 - 30MΩ
0 - 100MΩ
0 - 300MΩ
0 - 300Ω
0 - 1kΩ
1 YEAR ±
5ºC
0 - 3MΩ
0 - 30Ω
0 - 100Ω
90 DAY ±
5 ºC
0 - 300kΩ
0 - 3Ω
0 - 10Ω
RESOLUTION
Resolution at
default
In brackets
0 - .30kΩ
10nΩ (100nΩ)
0 - 300mΩ
0 - 1Ω
RANGE
0 - 1GΩ
0 - 3kΩ
0 - 10kΩ
www.timeeusa.com
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
57
58
AC Voltage
(All AC Voltages ± 50uV)
AC Current
(All AC Current ± 50nA)
RANGE
RESOLUTION *
90 DAY ±5ºC
1 YEAR ±5ºC
RANGE RESOLUTION * 90 DAY ± 5ºC
1 YEAR ± 5ºC
0 - 30mV
1uV
0.05% + 4uV
0.06% + 4uV
0-30uA
1nA
0.1% + 8nA
0.2% + 10nA
0 - 300mV
10uV
0.05% + 40uV
0.06% + 40uV
0-300uA
10nA
0.1% + 80nA
0.2% + 100nA
0 - 3V
100uV
0.05% + 400uV 0.06% + 400uV
0-3mA
100nA
0.1% + 800nA
0.2% + 1uA
0 - 30V
1mV
0.05% + 4mV
0.06% + 4mV
0-30mA
1uA
0.1% + 8uA
0.2% + 10uA
0 - 300V
10mV
0.15% + 0.1V
0.2% + 0.12V
0-300ma
10uA
0.1% + 80uA
0.2% + 100uA
0 - 3kV
100mV
0.15% + 1V
0.2% + 1.2V
0-3A
100uA
0.15% + 1mA
0.2% + 1mA
0-30A
1mA
0.15% + 10mA 0.2% + 10mA
Voltage AC + DC / Current AC + DC
Total measurement error will not exceed the sum of the separate AC + DC accuracy spec, plus one display digit.
PRT (PT100) Temperature
RANGE
RESOLUTION
-200ºC to
+600ºC
0.001ºC
Capacitance (All Capacitances ± 1pF)
90 DAY ± 5ºC 1 YEAR ± 5ºC RANGE RESOLUTION 90 DAY ±5ºC
(5 Digit)
0.05ºC
0.06ºC
0-30nF
1pF
0.2% + 20pF
1 YEAR ±5ºC
0.25% + 20pF
NOTES:
Only available in four terminal mode on the 300Ω range.
0-300nF
10pF
0-3uF
100pF
0.2% + 2nF
0.25% + 2nF
Frequency
Frequency may be measured on either voltage or current
inputs if the AC option has been fitted.
0-30uF
1nF
0.2% + 20nF
0.25% + 20nF
0-300uF
10nF
0.2% + 200nF
0.25% + 200nF
FREQUENCY
RANGE
RESOLUTION
90 DAY ±
5ºC
1 YEAR ±
5ºC
0-100kHz
1Hz
10 + 1
12 + 1
0.2% + 200pF
0.25% + 200pF
Accuracy stated as 90 day and 1 year specification for all ranges ± 5ºC in 6 digit mode for DC and 6 digit mode for AC.
5075 Operation Specifications
N Digits
Changes the reading resolution, which can be changed from 4 up to 7 digits, (depending on the scale selected).
Null
Null facility is available on all D.C. ranges, Ohms and Capacitance. Null is not available on A.C. or frequency.
When this key is pressed, the DMM will accept the measured present value as the zero value for the range selected. If
auto-range is on, the unit will null each range. This is useful for cancelling an offset voltage or for zeroing the value of the
test leads on resistance.
Auto Ranging
Auto-range (AUTO) will select the optimum range for the measurement. This will introduce very little delay for the
operator. The indicator above the keypad will show when the D.M.M is in auto-range mode.
Filter
The filter alters the integration time of the reading. Filter times are 150ms, 250ms, 500ms, 1s, 2s, 4s, 8s, 16s, 32s & off.
Internal Temperature
Internal Temperature controlled at 35ºC ± 2ºC with an ambient temperature of 20 - 28ºC
Advanced Operation Specifications
Ohms Compensation
Cancels the effects of any offset voltages by first measuring the input voltage with the current source on and the
measuring the voltage with the current source off. The induced voltage is the difference between the two voltages, thus
giving a more accurate reading. Can be used in 2 and 4 wire mode for measurements up to 100KΩ. Ohms compensation
doesn’t work on ranges above 100 KΩ.
Diode / Zener Diode Test
The diode test function will passes a current of 1mA through the diode under test and displays the diode forward voltage.
May be used for zener diodes up to 10V.
Self Test Reset
The instrument can perform a self-test of all its digital circuits including the IEEE and RAM.
Max – Min
This function displays the maximum and minimum readings of the input. By using the up and down keys the Maximum,
Minimum or Present value input may be displayed.
Peak Hold
This function will display the peak value measured. By using the up and down keys the Peak value or Present input may
be displayed.
www.timeeusa.com
58
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
59
Advanced Operation Specifications
Component Test
Used for component selection. If a component to be tested must fall between a high and low value, component test can
be used to make the selection process quicker. It provides a visual display which moves a pointer between the high and
low values input, and also indicates whether the component is higher or lower in value than the high and low points if it
doesn’t fall between them.
PRT Temp
PT100 elements can be measured and displayed in ˚C using this function.
Dual Display
Display Voltage and frequency of the input or the current and frequency (if the AC module has been installed), for A.C.
inputs.
Analogue Filter
The analogue filter can be switched into the input circuit to remove any high frequency noise that may be present on the
input.
Auto dynamic filter
The Auto Dynamic filter automatically selects the most appropriate filter period. The auto dynamic filter will increase or
decrease the filter period (up to the maximum set using the filter key) depending upon the stability of the input signal.
Continuity / Sample beep
Continuity tests can be performed by selecting this option when in resistance mode. Any value below 30% of the full
range will produce the continuity beep.
Sample beep alerts the operator to a new reading being displayed.
Internal Date / Time
Date & Time can be displayed or entered using this option.
Internal Temp
The internal temperature of the 5075 can be displayed and is updated approximately every 5 minutes. The internal
temperature is used to perform an internal calibration when the temperature varies by 1oC, thus insuring the temperature
co-efficient of the unit remains negligible.
Remote control
This instrument implements the requirements of the IEEE - 488/1978 standard.
The IEEE - 488 interface, sometimes called GPIB (General Purpose Interface Bus) or the HPIB (Hewlett Packard
Interface Bus) allows remote control of the instrument by a suitable computer or controller.
Repetitive calibration work can be speedily and accurately carried out, giving printed results if required.
The main limitations of the IEEE are :1) A maximum of 15 devices on the bus.
2) The maximum bus length should not be greater than 20m or number of devices x 2, which ever is the shorter.
Scanner (option)
The scanner option for the 5075 DMM consists of an internally fitted relay board. This board provides 10 input channels.
Up to two boards may be fitted giving up to 20 channels. The relays switch all 4 input terminals: V+, V-, I+, I– to one of
10/20 inputs via the 25 way ‘D’ connectors.
The scanner card may be used for voltage, current, resistance, capacitance, frequency, and PT 100.
Scanner Specifications
Maximum voltage: 200V DC / 150V AC
Contact resistance: Less than 150mΩ
Maximum current : 1A DC / 1A AC
Operating life: Up to 200 million operations
Thermal EMF: Less than 2uV per contact
Operating time: 20ms
5075 General Specification
Power:
Dimensions:
Weight:
Operating Temperature:
Optional Extras:
110/220/240V A.C. – 50/60Hz
W 16.7 x H 3.5 x D 15.5” (423w x 89h x 393d mm)
19 lbs (8.5 Kg)
0 – 50˚C
Low Thermal 10 Channel Scanner
19” Rack Mount Kit
Calibration Certificates
Ordering Information
Code
Description
5075
7 Digit Precision Digital Multimeter
9726
Low Thermal 10 Channel Scanner
9728
19” Rack Mount Kit
9162
Factory Calibration Certificate
9130
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
59
60
5033 - 3 Channel Programmable DC Power Source
Time Electronics
Calibration, Test & Measurement
 0 - 20V DC 2A drive capability
 40 watts max per channel
 10uV resolution setting
 Programmable via GPIB interface
 Easy to use command language
 4 Terminal Output
 Front-panel LEDs show status of each channel
The 5033 provides 3 independent channels of 0 to 20V DC, settable in 10uV steps. A 2A
drive capability allows up to 40W per channel to be output. A precision current shunt is
incorporated in each channel and allows read-back of the current supplied.
The high resolution on the voltage and current make this power source ideal for calorimetry
and other applications requiring very accurate control of DC power input. Power can be
controlled to better than a few ppm.
The excellent resolutions for the voltage output and current readback are matched by
stability performance that allows test runs of 24hrs or more and still maintain precision. The
voltage output is stable to better than 2ppm per 24hrs at full load and the basic temperature
coefficient (TC) is better than 1ppm/°C. Measurement of the current is done very accurately
using a precision shunt.
Full 4 terminal operation is provided to compensate for volt drops in connection leads.
Front panel indicators provide the user with clear indications of data transfer and also show
when errors have occurred or invalid commands have been issued. The unit is constructed
in a standard 19” Euro case and is suitable for rack or bench use. All connections are at the
rear of the unit.
www.timeeusa.com
60
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
61
5033 Technical Specifications
No. of Channels:
3 - fully floating
Output Voltage:
0 - 20V DC
Output Current:
2A max. Programmable limit, 10mA to 2A in 10mA steps
Output Power:
40W max per channel
Output Terminals:
2 wire or 4 wire. low thermal emf construction
Setting Resolution:
22 bits (0.25ppm)
Accuracy:
20ppm of output + 400uV
Linearity:
< 10ppm of f.s.
Output Resistance:
< 1mΩ
Stability:
< 2ppm/24hrs, < 5ppm/month, < 15ppm/year
Noise level:
< 1ppm at 1Hz and lower
Temp Coefficient:
< 1ppm/°C
Front Panel display:
For each channel, ‘Error’, ‘Data transfer’, ‘Power’
Fuses:
Mains input power, Channel input power 3 x 3A slow blow
Current read-back:
0.1Ω internal precision
Channel outputs, current sense, and GPIB
General Specification
Interface:
GPIB
Protocol:
SCPI command language
Mains Power:
115V/230V (+/-5%), 50/60Hz
Construction:
19” 3U Rack mount frame. Standard Euro card modules
Dimensions:
19 x 12.9 x 5.25” (483 x 331 x 134mm)
Weight:
32 lb (14 Kg)
Ordering Information
Code
Description
5033
3 Channel High Precision Programmable DC Power Source
9169
Factory Calibration Certificate
9116
UKAS/NIST Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
61
62
5077 Power Calibrator
Time Electronics
Calibration, Test & Measurement
 Up to 20kW
 Up to 1050V AC/DC
 Up to 22A AC/DC
 +90.0 deg to -90.0 deg
 0.00 to 1.00 Lead/Lag
 45 to 400 Hz in 0.1Hz steps
 RS232 / GPIB / USB Interface
 100A AC current transformer option
The 5077 is controlled remotely from a standard PC via the RS232 (or USB) interface, or
directly from Time Electronics' 5051 Calibration System.
A user-friendly virtual front panel allows the four parameters to be set individually. Frequency
can be set in 0.1Hz steps from 45 to 400Hz, and phase in 0.1-degree steps. Alternatively
power factor (PF) can be set in 0.01 steps.
The output can be displayed as VA or Watts.
www.timeeusa.com
62
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
63
5077 Technical Specifications
Accuracy specifications are shown as ppm or % of output + floor. They apply for settings of between 10% to 100% of range full scale.
Specifications apply at any ambient temp of 22°C +/- 3°C after the calibrator has warmed up for at least 2 hours. All values are relative to
calibration standards. Full specification details available on request.
DC VOLTAGE
Range
Accuracy %/yr
Output Resistance
Max Output Current
Resolution
*2V
0.01 + 500uV
< 0.5 ohm
20mA
1uV
*20V
0.01 + 500uV
< 0.5 ohm
20mA
10uV
300V
0.02 + 30mV
< 5 ohm
20mA
100uV
1kV
0.05 + 50mV
< 10 ohm
10mA
1mV
*Accuracy is specified at minimum current output.
DC CURRENT
Range
Accuracy %/yr
2A
20A
Compliance Voltage
Resolution
0.03 + 500uA
5V
100uA
0.05 + 6mA
4V
1mA
AC VOLTAGE (45Hz to 400Hz 0.02% Accuracy)
Range
Accuracy %/yr
Output Resistance
Max Output Current
Resolution
100uV
*2V
0.03% + 500uV
< 0.5 ohm
20mA
*20V
0.03% + 2mV
< 1 ohm
20mA
1mV
**300V
0.06% + 30mV
< 5 ohm
20mA
10mV
**1kV
0.08% + 90mV
< 10 ohm
10mA
100mV
*Accuracy is specified at minimum current output.
**Accuracy is specified at 100Hz for current outputs less than 5A
AC CURRENT (45Hz to 400Hz 0.02% Accuracy)
Range
Accuracy %/yr
Compliance Voltage
Resolution
2A
0.1% + 2mA
3.5V
100uA
20A
0.1% + 20mA
3V
1mA
PHASE ANGLE (Applies to outputs above 22 Volts)
Frequency
Range
Accuracy %/yr
Resolution
45 to 99Hz
-90.0 to +90.0 deg
0.3 deg
0.1 deg
100Hz to 400Hz
-90.0 to +90.0 deg
1 deg
0.1 deg
POWER FACTOR
Frequency
Range
Resolution
45 to 400Hz
0.00 to 1.00
0.01
The accuracy of the power is complex and is determined by using a formula, which combines the errors due to Voltage, Current, and Phase.
Power Acc (%) = SqrRt (Vacc^2 + Iacc^2 + Phase Correction^2)
Where Phase Correction (%) = 100x(1-Cos(Phase+PhaseAcc)/Cos Phase)
General Specification
Power:
Dimensions:
Weight:
Optional Extras:
100 - 230V AC 50/60 Hz
W 17.6 x H 7.8 x D 32.8" (W 440 x H 198 x D 580mm)
55 lbs (25kg)
100 Amp AC Current Transformer
Test Lead Set
Ordering Information
Code
Description
5077
PowerCal - AC/DC Programmable Power Calibrator
9790
100 Amp AC Current Transformer Option
9735
Test Lead Set
9160
Factory Calibration Certificate
9124
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
63
64
9840 Series Power Calibrators (Single and 3 Phase)
Time Electronics
Calibration, Test & Measurement

4 voltage ranges: 57 - 110 - 220 - 500V

4 current ranges: 1 - 5 - 20 - 100A

Frequency: 45 - 70Hz

Phase angle: -90/0/+90°
(0.1° resolution)

Total harmonic distortion:
Pre-settable from 1% to 15%
The 9840 series calibrators are used for adjusting, checking and verification of measuring instruments used in
power engineering. These include active and reactive power meters, phase meters, frequency meters,
ammeters, voltmeters, transducers, monitoring systems, and frequency, voltage and current relays.
It is constructed in a standard 19” rack-mount size case. Voltage and current output signals are set by multiturn potentiometers and are simultaneously indicated on 4.5 digit LED displays. Frequency and phase angle
are also set by multi-turn potentiometers and are displayed on 4 digit LED indicators.
Instruments to be calibrated can safely be connected to the outputs without changing the set values since the
calibrator can be switched to ‘standby’ mode to isolate the output terminals.
Sinusoidal signals are generated on both voltage and current outputs. If required, between 1% and 15%
harmonic distortion can be added to the signals.
Three Phase Calibrator Set
Calibrator 9840 can work in a three phase set (order code 9845). It consists of one calibrator in basic
configuration (phase L1) and two calibrators in special configuration (phase L2 and phase L3). Calibrator phase
L1 controls phase L2 and L3 by means of analogue and digital signals. All connections are on the rear panels.
The calibrator set is able to generate a symmetrical three phase vector, programmed from control calibrator
phase L1. The phase angles between the 3 phases are shown on the displays.
Shift angle between voltage signals
120° ±1° *
Maximum amplitude difference in each phase from
average value (voltage)
±1% of value
Maximum amplitude difference in each phase from
average value (current)
±1% of value
Maximum difference in phase angle between voltage
±1° *
and current
* for settings greater than 10% on voltage and current range
www.timeeusa.com
64
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
65
9840 Series Technical Specifications
Parameter
Range
Settings Span
Resolution
Accuracy
Maximum Load
57V
0.5 - 60V
0.01V
[email protected]
110V
1.00 - 125V
0.01V
220V
2.0 - 250V
0.1V
[email protected]
±0.05% of set value
±3 digits
Voltage
[email protected]
500V
3.0 - 500V
0,1V
[email protected]
1A
0.01 - 1.3A
0.0001A
[email protected]
5A
0.05 - 6A
0.001A
20A
0.2 - 20A
0.001A
[email protected]
100A (9841)
1 - 100A
0.01A
0.7/[email protected]/100A
Frequency
45 - 70Hz
0.01Hz
±0.02Hz
Phase
0.0 - +/-90.0°
0.1°
±0.5° *
±0.05% of set value
±3 digits
Current
[email protected]
Total Harmonic Distortion (adjustable 1 - 15%)
0.5% of set value
Dimensions (width x height x depth )
478 x 194 x 342 mm / 14Kg
Power Supply
230V±10% / 50Hz 200VA, 110V option
* for settings greater than 10% of voltage and current range
Parameter
Operating conditions
Ambient temperature
+5...+40°C
Atmospheric pressure
70...106kPa
Relative humidity
20…80% non-condensing
Power supply voltage
230V ±10% 50Hz +/-5Hz. 110V 60Hz optional
Power supply freq
45…65Hz
Power supply w/form
Sine, distortion factor <0.05
Warm up time
30 min
Parameter
Requirement
Safety
Class 1 according to EN61010
Insulation (50Hz) power supply pins – case
1.5kV
Voltage and current output terminals – case
2kV
Voltage output terminals – current output terminals
2kV
Control D-sub connection – case
500V
Degrees of protection electrical equipment
IP20 according to IEC529
Climatic conditions
Group I according to IEC359
Power consumption
200VA max
Dimensions (with/height/depth), Weight
478/194/342mm, 14kg
Ordering Information
Code
Description
9840
Standard single phase source with current range up to 20A
9841
Single phase source with additional 100A current range
9845
Three phase symmetrical source with current range up to 20A
9846
Three phase symmetrical source with additional 100A current range
9847
Three phase asymmetrical source with current range up to 20A
9848
Three phase asymmetrical source with additional 100A current range
www.timeeusa.com
Tel: 516-723-9909
DMMS AND POWER CALIBRATORS
Email: [email protected]
65
66
www.timeeusa.com
66
Tel: 516-723-9909
Email: [email protected]
67
Multifunction Calibrators
Time Electronics' range of multifunction calibrators have the ability to calibrate both
new and traditional equipment. Each calibrator encompasses a wide range of
capabilities to cover multiple functions. In addition our PC based EasyCal calibration
software is ideal to automate the calibration process, increase speed of calibration
and consistency of results. It produces calibration certificates and reports to ISO9001
quality standards.
1017 Transportable DC Multifunction VIR Calibrator (0.005% Accuracy) ........................................... 68
5011 Resistance/Temperature Calibrator ........................................................................................... 70
5018 Programmable DC/AC Voltage/Current Calibrator ..................................................................... 72
5045 Oscilloscope and Timer/Counter Calibrator ............................................................................... 74
5025 Multifunction Calibrator............................................................................................................... 76
5051 Multifunction Calibration System ................................................................................................ 78
9780/7042/9796/9773 Multifunction Calibration Equipment Accessories ........................................... 80
Also see:
EasyCal Calibration Software on page 82.
TE CalBench and module options on page119.
www.timeeusa.com
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
67
68
1017 Multifunction DC V/I/R Calibrator
Time Electronics
Calibration, Test & Measurement
 DC Volts 10nV to 100V
 DC Current 100nA to 100mA
 Resistance 10m to 10k
 0.005% (50ppm) accuracy
 1 ppm setting resolution
 Noise < 2ppm (0.1 to 1Hz)
 Stability <5ppm/day <25ppm/yr
The 1017 is a high performance portable DC calibrator for use in the field or laboratory. It is
constructed in a durable, compact plastic case with a tilt stand/carry handle.
Five DC voltage ranges from 10mV to 100V full scale are available, each with a 6-digit
(1ppm) resolution. The DC current range is 100mA full scale with a 100nA (1ppm) resolution.
Resistance from 0.01 to 10k is available 0.01 steps.
The voltage, current and resistance ranges make it suitable for calibrating a wide range of
transducers, from thermocouples, 4-20mA and 0-10V transmitters, to Platinum Resistance
Thermometers, all in the same instrument.
Power
Mains or rechargeable battery. Battery operation enables good performance where earth
loop and noise pick-up occurs.
Stability v Temperature and Time
Outstanding performance is due to the use of special computer selected reference diodes
and the latest in resistor technology. The special low-thermal emf terminals reduce errors
when working with microvolt signals.
Digital Deviation Control
Allows the output to be increased/decreased in % terms from 0 to +/-0.999%. This provides a
direct read-out of error and simplifies the recording results for calibration certificates. It
enables the user to immediately see if the unit under test is within specification.
www.timeeusa.com
68
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
69
1017 Technical Specifications
Voltage Ranges/Accuracy:
0 - 9.99999mV in 10nV steps,
0 - 99.9999mV in 100nV steps,
0 - 999.999mV in 1µV steps,
0 - 9.99999V in 10µV steps,
0 - 99.9999V in 100µV steps,
± 0.02% of setting ± 0.005% of range
± 0.01% of setting ± 0.004% of range
± 0.005% of setting ± 0.002% of range
± 0.005% of setting ± 0.002% of range
± 0.01% of setting ± 0.004% of range
The above accuracies are independent of thermal emfs which can be
2uV or more depending on the type of leads and connections used.
Output resistance:
10mV & 100mV: 10. 1V & 10V: <150m. 100V: <1
Drive current max:
10&100mV: as 10 o/p resistance. 1V&10V: 150mA; 100V: 10mA.
Current Range/Accuracy:
0 - 99.9999mA in 0.1uA steps, ± 0.02% of setting + ± 0.004% of range.
Drive voltage max: 10V
Resistance Range/Accuracy:
0 - 9.99999k in 0.01 steps, ± 0.05% of setting +/- 0.003% of range.
Power rating:
0.25W per resistor
End resistance: less than 200m
Deviation Control:
0% to 0.999% in 0.001% steps. Deviation accuracy: V&I output, 0.5%.
Temperature Coefficient:
<5 ppm per ºC
Long Term Stability:
<5ppm/day, <15ppm/90day, <25ppm/year
Short Term Stability – Noise:
10mV range: <0.2uV/sec, <0.3uV/10sec, <0.4uV/min
100mV range: <0.2uV/sec, <0.4uV/10sec, <0.6uV/min
1V range:
<0.2uV/sec, <0.5uV/10sec, <1.5uV/min
10V range:
<1.0uV/sec, <2.0uV/10sec, < 8.0uV/min
100V range: <40uV/sec, <100uV/10sec, <500uV/min
100mA range: <0.2uA/sec, <0.4uA/10sec, <1.0uA/min
Warm-up and Settling time:
Warm-up: <10 mins to full accuracy. Settling: < 0.5 secs, 100V range 5 secs.
Output Connections:
The output is via low thermal emf terminals (0.2uV/ºC). A mains earth
terminal is provided for screening purposes. Output polarity can be
selected by a switch on the front panel.
Power Supply:
The 1017 can be powered continuously from a 230V 50/60 Hz (110V to
order) mains supply, or from the internal rechargeable NiCad battery pack.
A front panel indicator shows the state of charge at all times.
Operating temperature:
0 to 50ºC (32 to 120ºF). 15 to 25ºC for optimum performance.
Operating Humility:
10 to 90% non-condensing 25ºC (77ºF)
General Specification
Dimensions:
11.4 x 9.8 x 4.3” (290 x 250 x 110mm)
Weight:
5.4 lb (2.4 kg)
Optional Extras:
Calibration Certificates
Ordering Information
Code
Description
1017
Multifunction DC V/I/R Calibrator
9152
Factory Calibration Certificate
9109
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
69
70
5011 Resistance / Temperature Calibrator
Time Electronics
Calibration, Test & Measurement

1  to 120 M

RTD Simulation

Thermocouple Simulation

DCV & DCI Options

10MHz Frequency Option

RS232/GPIB/USB

Front Panel Operation
The 5011 is primarily a programmable resistance / RTD source. With the ability to add DC Voltage,
Thermocouple Simulation and DC Current the 5011 is truly a versatile temperature calibrator.
High performance resistance of is offered as standard with an accuracy of 0.01% and 1mΩ resolution
from 50Ω to 1kΩ.
Simple front panel operation allows the user to quickly set the function and output required.
Using the jog / shuttle dial deviation the user can finely adjust the output value as a percentage (+/9.99%). All this information is shown on a clear, easy to read LED display.
As standard the 5011 uses a SCPI command structure for programming. The 5011 also supports the
older 9811/19/20 command set making it an ideal replacement for these models.
The DCV / Thermocouple option provides a DC voltage source (+/- 20V) and simulates thermocouple
types K, J, T, R, S, N, E and B.
A DC Current option is available which sources up to 220mA. This makes the 5011 ideal for accurate
process control calibration.
A 0.1 Hz to 10 MHz frequency (Period 100nS to 10s) option is also available. The output is variable
with a best resolution setting of 0.1Hz.
Calibration Made Easy
Connect the 5011 to a PC/Laptop (via RS232, GPIB or USB) installed with Time Electronics EasyCal
and automate the calibration process. Increase speed of calibration and consistency of results;
produce calibration certificates and reports to ISO 9001 quality standards.
www.timeeusa.com
70
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
71
5011 Technical Specifications
Accuracies quoted are for 1 year.
THERMOCOUPLE SIMULATION
RESISTANCE
Range
Accuracy
Resolution
Type
Range ºC
Acc. ºC
-210 to 150 / 150 to 1200
0.15 / 0.3
1Ω – 20Ω
0.01% +/- 5mΩ
1Ω
J
20Ω – 99.999Ω
0.01% +/- 5mΩ
1mΩ/5mΩ*
K
-270 to 190 / 190 to 1250
0.5 / 0.6
1mΩ
T
-200 to 150 / 150 to 400
0.4 / 0.5
-50 to 800 / 800 to 1750
0.8 / 2.0
100Ω – 999.999Ω
0.01% +/- 5mΩ
1kΩ – 9.999kΩ
0.02% +/- 20mΩ
1Ω
R
10kΩ – 99.999kΩ
0.01% +/- 1Ω
1Ω
S
-50 to 850 / 850 to 1750
0.9 / 2.0
B
100 to 1200 / 1200 to 1800
1.0 / 2.0
N
-270 to 260 / 260 to 1300
0.5 / 0.4
E
-50 to 1000
0.3
100kΩ – 999.99kΩ
0.01% +/- 10Ω
10Ω
1MΩ – 9.9999MΩ
0.02% +/- 100Ω
100Ω
10MΩ – 120MΩ
0.1% +/- 1kΩ
1kΩ
Temp Coefficient:
Power Rating:
Maximum Voltage:
Resistance Switch Time:
Operation Time:
End Resistance Variation:
Cold Junction Compensation +/- 0.5ºC (applies to ambient
changes of less than +/- 1ºC at 23 ºC)
less than 50 ppm per ºC
0.1 Watt per resistor
250 V
< 250us
< 300ms
< 2.5mΩ
The accuracy of the thermocouple simulation is determined by the
accuracy of the 5011’s DC Voltage function and the accuracy of
the standard thermocouple tables (BS EN 60584-1) published by
the British Standards Institute.
The 5011 uses precise digital interpretation of the tables to output
voltage levels that are within the accuracies specified in the table.
*Output Setting Resolution below 50Ω is 5mΩ
DC VOLTAGE
PRT SIMULATION
RTD Type
Alpha Coeff
Range
Accuracy
Pt100
0.003850
-180 to -100ºC
0.1ºC
Pt100
0.003850
-100 to 850ºC
0.05ºC
It should be noted that the accuracy of the PRT simulation is
determined by the accuracy of the PRT tables (BS EN 60751)
published by the British Standards Institute. The 5011 uses precise
digital interpretation of the tables to output resistance values that are
within the accuracies specified in the table.
Range
Accuracy
Resolution
20mV
100ppm + 4uV
100nV
200mV
30ppm + 6uV
1uV
2V
25ppm + 20uV
1uV
20V
25ppm + 150uV
10uV
DC CURRENT (Compliance Voltage: 11V)
Range
220uA
2.2mA
22mA
220mA
FREQUENCY / PERIOD (2V pk/pk approx)
0.1Hz to 10MHz / 100nS to 10s Accuracy 20ppm
Accuracy
150ppm + 15nA
100ppm + 40nA
80ppm + 200nA
80ppm + 3uA
Resolution
1 nA
10 nA
10 nA
100 nA
General Specification
Power:
110 V to 240 V AC 50/60 Hz. 30 VA
Operating Temperatures:
0-45 ºC. 22 ºC +/- 3 ºC for full specification.
Dimensions:
Weight:
Optional Extras:
W 18 x D 11 x H 7 “ (W 450 x D 272 x H 152 mm).
15.4lbs (7 Kg)
DC Voltage and Thermocouple Simulation, DC Current, 10MHz Frequency.
Factory or UKAS/NIST Calibration Certificates
Rack Mount Kit
Ordering Information
Code
Description
5011
Resistance / Temperature Calibrator
9711
DC Voltage and Thermocouple Simulation
9718
DC Current 220mA (Only available if 9711 DC Voltage option fitted)
9729
Frequency Option (10MHz digital)
9728
Rack Mount Kit
9115
UKAS/NIST Calibration Certificate (ISO 17025)
9171
Factory Calibration Certificate
9747
EasyCal Calibration Software
www.timeeusa.com
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
71
72
5018 Programmable DC-AC V-I Calibrator
Time Electronics
Calibration, Test & Measurement

0 - 22V DCV, 15 ppm accuracy

Optional 0-22VAC, 220 VDC & 1kVDC

Optional 0-220mA AC/DC

Ramping Feature

GPIB, RS232 & USB Interface

Ideal for ATE applications - Rack mount kit available
Better than 15ppm/year Accuracy
The outstanding accuracy and stability of the 5018 is achieved by the use of a patented
circuit. It incorporates a dedicated micro-processor to continually monitor the state of a bank
of precision voltage references. The basic digital to analogue converter has 22 bit (0.25ppm)
resolution. Linearity and temperature coefficient are compensated in software to better than
0.1ppm of full scale per °C. For the DC 2V/20V ranges short term stability is <0.5ppm/day
and <2ppm/month. An external 1000:1 screened attenuator is available as an option for very
low noise AC output.
Display
Simple front panel operation allows the user to quickly set the function and output required.
Using the jog / shuttle dial deviation the user can finely adjust the output value as a
percentage (+/-99.99%). All this information is shown on a clear, easy to read LED display.
GPIB, RS232 & USB Interface
These interfaces allow the 5018 to be connected to a PC and controlled by an external
program such as Time Electronics’ EasyCal calibration software.
The 5018 uses a SCPI command structure for programming. This makes writing control
programs in Visual Basic, C and Labview a simple task.
Ramping Feature
The 5018 includes an internal ramping feature. A ramp rate per range for each function can
be set. The option to ramp the output can be turned on or off via the front panel.
Calibration Made Easy
Connect the 5018 to a PC/Laptop (via RS232, GPIB or USB) installed with Time Electronics
EasyCal and automate the calibration process. Increase speed of calibration and
consistency of results; produce calibration certificates and reports to ISO 9001 quality
standards.
EasyCal has the ability to control a wide range of programmable instruments and
comprehensive ATE systems can be configured to control a variety of applications. It has full
read back capability and therefore can perform closed loop testing. Conditional tests can be
configured to allow decision making to further enhance the usefulness.
www.timeeusa.com
72
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
73
5018 Technical Specifications
Accuracy specifications are shown as ppm (or %) of output + floor and apply for settings between 10% and 100% of range.
Specifications apply at an ambient temp of 22°C +/- 3°C after the calibrator has warmed up for at least 1 hour.
DC VOLTAGE
Range
Accuracy 1 year
Output Resistance
Max Output Current
Resolution
22mV
30ppm + 4uV
10Ω
-
100nV
220mV
15ppm + 6uV
10Ω
-
1uV
2.2V
15ppm + 20uV
< 0.15Ω
20mA
1uV
22V
15ppm + 150uV
< 0.15Ω
20mA
10uV
Range
Accuracy 1 year
Output Resistance
Max Output Current
Resolution
220V*
15ppm + 1mV
<0.25Ω
10mA
100uV
1kV*
25ppm + 3mV
<1Ω
1mA
1mV
DC HIGH VOLTAGE OPTIONS 9720/9721
*Minimum Load 20kΩ
DC CURRENT OPTION 9718
Range
Accuracy 1 year
Compliance Voltage
Resolution
220uA
150ppm + 15nA
11V
1nA
2.2mA
100ppm + 40nA
11V
10nA
22mA
80ppm + 200nA
11V
10nA
220mA
80ppm + 3uA
11V
100nA
AC V OPTION 9719 10Hz to 20kHz Sine 0.01% crystal controlled
Range RMS
Accuracy % 1yr
10Hz - 1kHz
Accuracy 1 yr
1kHz - 10kHz
Accuracy % 1yr
10kHz - 20kHz
Output Res
Max Output
Current
Resolution
22mV
0.05% + 100uV
0.05% + 150uV
0.05% + 250uV
10Ω
-
1uV
220mV
0.04% + 100uV
0.04% + 150uV
0.04% + 250uV
10Ω
-
1uV
2.2V
0.03% + 170uV
0.03% + 250uV
0.03% + 300uV
<0.15Ω
20mA
10uV
22V
0.03% + 2.0mV
0.03% + 3.0mV
0.03% + 4.0mV
<0.15Ω
20mA
100uV
AC CURRENT OPTION (available if current & AC options are fitted) 20Hz to 1kHz (Sine)
Range RMS
Accuracy 1 year
Compliance Voltage RMS
Resolution
220uA
0.07% + 300nA
5V
10nA
2.2mA
0.05% + 300nA
5V
10nA
22mA
0.05% + 3uA
5V
100nA
220mA
0.05% + 30uA
5V
1uA
General Specification
Power:
100V to 250V AC (+/-5%) 50/60Hz, less than 100 W
Dimensions:
W 18 x D 11 x H 7 “ (W 450 x D 272 x H 152 mm).
Weight:
18lbs (8.2Kg)
Ordering Information
Code
Description
Code
Description
5018
Programmable DC/AC V/I Calibrator
9142
Factory Calibration Certificate
9718
Current Option (220mA Max)
9747
EasyCal Software - see separate datasheet
9719
AC Option (22V Max)
9743
PCI-GPIB Interface Card (Fitted in PC to control 5018 via GPIB)
9720
1 KV DC Option
9794
USB-GPIB Interface (External unit PC USB for control via GPIB)
9721
220V DC Option
9597
GPIB Interface Cable (2m length for connection of GPIB to 5018)
9104
UKAS/NIST Calibration Certificate
9728
19” Rack Mount Kit
www.timeeusa.com
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
73
74
5045 Oscilloscope Calibrator
Time Electronics
Calibration, Test & Measurement











1mV – 220V Square Wave/DC
Frequency 0.1 – 100MHz
Time Markers 15s to 10ns
Fast Rise <300ps
Front Panel Control
PC Virtual Control
External reference input
2 GHz Sweep Option
Rubidium Option
Current Probe Adaptor
RS232/USB/GPIB
The 5045 is a versatile, high accuracy calibrator capable of calibrating a wide range of oscilloscopes
and timer/counters. It provides a wide range of outputs for amplitude, frequency, period and
bandwidth. Amplitude calibration is achieved by a DC signal or 1kHz square-wave, ranging from 1mV
to 220V (2V max for 50 ohm loads). Deviation up to ±9.99% allows fine adjustment of amplitude and
direct read-out of error. Accurate frequencies are generated from a temperature controlled quartz
crystal oscillator. Timing accuracy of 0.1ppm is suitable for most oscilloscopes and timer counters. A
precise square-wave output provides a fast rise time of less than 300ps, which allows bandwidth
testing up to 600MHz.
Simple Operation
Functions and ranges are easily accessed from the front panel. Increase and decrease keys per digit,
are used to quickly set the output value. Deviation control then enables the user to finely adjust the
output value as a percentage (+/-9.999%). All this information is shown on a clear, easy to read LED
display.
Virtual Front Panel Software
The 5045 comes with Time Electronics’ windows based ‘Virtual Front Panel’
interface that enables the user to control the unit via a laptop or PC.
2 GHz Levelled sine-wave option
For precise bandwidth determination and frequency response analysis the 2 GHz option is available.
The ability to sweep the frequency output from 100MHz to 2 GHz and adjust the amplitude to 0.5V,
1.0V and 1.5V pk-pk ensures accurate analysis of oscilloscope input amplifiers.
Current probe calibration
For calibration of oscilloscope current probes an external adaptor is available. This converts the
5045’s amplitude output to current and covers the range 0.1mA to 100mA pk-pk, 0.2% accuracy, DC
or 1kHz.
Rubidium frequency reference
Enhanced timing performance is available by specifying the rubidium frequency reference option
(9762). This option achieves timing accuracies required to calibrate high performance
Timer/Counters to 1 part in 10¹º.
Calibration made easy
To automate the oscilloscope calibration process the 5045 can be controlled using Time Electronics’
EasyCal calibration software. This reduces calibration times, ensures consistent results and produces
certificates to international quality standards.
www.timeeusa.com
74
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
75
5045 Technical Specifications
Function
Range
Specification (± output + floor)
0.1Hz to 10MHz
20MHz to 100MHz
± 0.1ppm
± 20ppm
10s to 100ns
50ns to 10ns
± 0.1ppm + 30ps
± 20ppm + 50ps
Duty Cycle
100Hz, 1kHz, 10kHz.
Settable from 0 to 100%
Amplitude
DC or 1kHz Square wave
1mV to 200mV
200mV to 20V
20V to 220V
1mV to 200mV (50Ω)
200mV to 2V (50Ω)
± 0.2% + 6uV
± 0.05% + 6uV
± 0.05% + 6uV
± 0.25% + 10uV
± 0.25% + 10uV
10MHz
Rise Time less than 300ps
Frequency*
Period*
Fast Rise
Resolution
Fixed Outputs in 1,2,5,10
Sequenced Steps
10uV
1mV
10mV
100uV
1mV
*Frequency amplitude: 1.5V pk-pk 0.1Hz to 100KHz. 1V pk-pk 200kHz to 100MHz.
Options
2 GHz Sweep
Rubidium reference
Current probe adapter
Range
Specification
100MHz to 200MHz
200MHz to 500MHz
500MHz to 1GHz
1GHz to 2GHz
1%
4%
10%
20%
Levelled sine-wave.
Settable amplitudes:
0.5V, 1V, 1.5V pk-pk
Rubidium atomic clock frequency reference. Increases accuracy to 1 part in 10¹º.
Battery powered external adapter for checking current probes. 0.1 - 100mA, 0.2% accuracy.
General Specification
Warm up
Settling Time
Standard Interfaces
Operation Environment
1 Hour to full accuracy
Less than 5 seconds
GPIB (IEEE-488), RS-232, USB
Temperature: Operating: 15 - 25 °C, Full Spec: 22 °C +/- 3°C, Storage: -10 °C to 50 °C
Humidity: Operating < 80% non condensing. Altitude 0 - 3km. Non Operating 3Km - 12km
Line Power
100 - 230V AC 50/60 Hz. Power Consumption 60W typical, 80W Max.
Dimensions
W 18 x D 11 x H 7 “ (W 450 x D 272 x H 152 mm).
Weight
18lbs (8.2Kg)
Ordering Information
Code
Description
5045
Oscilloscope/Timer Calibrator
9769
Programmable 2 GHz Levelled Sine Generator
9762
Rubidium Frequency Reference
9764
Current Probe Calibration Adaptor
9747
EasyCal Calibration Software
9728
19" Universal Rack Mount Kit
9147
Factory Calibration Certificate
9128
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: info[email protected]
75
76
5025 Multi Function Calibrator
Time Electronics
Calibration, Test & Measurement












0 - 1050 V AC/DC voltage
0 - 22 A AC/DC current
0 - 1GΩ resistance
Thermocouple simulation
Digital Frequency
Oscilloscope Calibration
PT100 simulation
Capacitance & Inductance
Power Calibration
Clamp Meter Calibration
GPIB, RS232 & USB Interface
Calibrate up to 4.5 digit DMM’s
Multi Instrument Calibration
A calibrator with a wide range of capabilities to cover multiple functions is a modern day necessity.
The 5025 is the ultimate multi-product calibrator, designed for both traditional and new measurement
equipment.
The 5025 can calibrate, bench and handheld multi-meters, frequency meters, ohm meters, ac/dc
millivoltmeters, thermocouple indicators, clamp meters, temperature indicators, timer counters,
oscilloscopes and many other measurement devices.
Simple Operation
Functions and ranges are easily accessed from the front panel. Increase and decrease keys per digit,
are used to quickly set the output value. Deviation control then enables the user to finely adjust the
output value as a percentage (+/-9.999%). All this information is shown on a clear, easy to read LED
display.
Flexible Options
The 5025 can be equipped to specific requirements. The standard unit is fitted with AC/DC voltage to
1050kV, AC/DC current to 22A, digital frequency to 10MHz, decade resistance to 1GΩ, conductance
and thermocouple simulation.
Individual options include; capacitance and inductance, full range resistance (incorporating PT100
simulation), and oscilloscope calibration. These options can be specified at time of order or fitted at a
later date by an authorised service agent.
In addition external adaptors are available for clamp meter calibration (up to 1000A), optical
tachometer calibration and low noise attenuation.
Calibration Made Easy
Connect the 5025 to a PC/Laptop (via RS233, GPIB or USB) installed with Time Electronics EasyCal
and automate the calibration process. Increase speed of calibration and consistency of results,
produce calibration certificates and reports to ISO 9001 quality standards.
www.timeeusa.com
76
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
77
5025 Technical Specifications
Range:
0 to ± 1050V
Voltage DC
Best 1 Year Specification:
± 15ppm of setting
Range:
0 to ± 22A. 1100A with Clamp Meter Adaptor
Current DC
Best 1 Year Specification:
± 80ppm of setting
Range:
1mV to 1050V (10Hz to 20kHz, Sine-wave)
Voltage AC
Best 1 Year Specification:
± 300ppm of setting
Range:
10uA to 22A (20Hz to 1kHz, Sine-wave)
Current AC
100A AC with CT. 1100A with Clamp Meter Adaptor
Best 1 Year Specification:
± 0.05% of setting
Range:
0 to 1GΩ (Fixed Values, decade steps)
Resistance
Best 1 Year Specification:
± 20ppm of setting
Range:
1 S to 1n S (Fixed Values, decade steps)
Conductance
Best 1 Year Specification:
± 20ppm of setting
Thermocouple
Range:
-270 to 1800°C (Type J,K,R,T,S,B,E,N)
Simulation
Best 1 Year Specification:
± 0.3 °C
10MHz Digital
Range:
0.1Hz to 10MHz / 100nS to 10S
Frequency/Period
Best 1 Year Specification:
± 20ppm of setting
Options
Range/Max Freq:
20 to 200mV/300kHz. 0.2 to 2V/1MHz. 2 to 20V/100kHz
Hi Frequency AC V
Best 1 Year Specification:
0.05% + 0.1mV
Values:
1nF,10nF,100nF,1uF,10uF & 100uF (100V Max)
Capacitance
Best 1 Year Specification:
± 0.25%
Values:
1, 1.9, 5, 10, 19, 50, 100, 190, 500mH - 1H & 10H
Inductance
Best 1 Year Specification:
± 0.1%
Range:
1Ω to 120MΩ (Variable)
Full Range Resistance
Best 1 Year Specification:
± 0.01% of setting
Range:
-200 to 850°C
PT100
Best 1 Year Specification:
± 0.1°C
Range:
22A, 1050V. Phase ± 90°
100A AC with CT. 1100A with Clamp Meter Adaptor
Power Calibration
Best 1 Year Specification:
ACV: 0.03%, DCV: 0.01%. ACI: 0.1%, ACV: 0.03%
Phase: 0.3°
Oscilloscope
Range:
0.1Hz to 100MHz / 100ns to 10s
Frequency/Period
Best 1 Year Specification:
± 0.1ppm of setting
Oscilloscope Duty Cycle
Values:
3 frequencies, 100Hz, 1kHz, 10kHz. Settable from 0 to 100%
Oscilloscope
Range:
0mV to 200V & 0mV to 2V 50Ω (Square-wave)
Amplitude
Best 1 Year Specification:
± 0.05%
Oscilloscope Fast-Rise
Values:
< 300ps. Bandwidth Checking up to 600 MHz
Range:
100MHz - 2.2GHz levelled sine-wave (0.5, 1, 1.5V pk-pk).
2.2 GHz Sweep
Best 1 Year Specification:
Amplitude ± 1%, Frequency ± 20ppm.
General Specification
Warm up
1 Hour to full accuracy
Settling Time
Less than 5 seconds
Standard Interfaces
GPIB (IEEE-488), RS-232, USB
Temperature: Operating: 15 - 25°C, Full Spec: 22°C +/- 3°C, Storage: -10°C to 50°C
Operation Environment
Humidity: Operating < 80% non condensing. Altitude 0 - 3km. Non Operating 3Km - 12km
Line Power
100 - 230V AC 50/60 Hz. Power Consumption 200W max
Dimensions
W 430mm, D 480mm, H 155mm, (17x18x6”) 16.5Kg (36.4lbs)
Ordering Information
Code
Description
Code
Description
9798
Capacitance and Inductance
9771
High Frequency AC Voltage
9774
Simulated Resistance (10Ω - 40 MΩ)
9747
EasyCal Software
9787
Full Range Resistance (1Ω - 120 MΩ)
9743
PCI GPIB Interface Card
9770
Oscilloscope Calibration
9794
USB to GPIB Interface
9761
2 GHz Sweep
9765
USB Interface
9790
100A AC Current Option
9597
GPIB Interface Cable
9780
Clamp Meter Adaptor 1 and 50 Turns
9728
19” Rack Mount Kit
9773
Optical Tachometer Calibration Adaptor
9796
Test Lead Set
9767
External Low Noise Attenuator 100:1
9159
Factory (NPL Traceable) Calibration Certificate
9766
External Low Noise Attenuator 1000:1
9103
UKAS Calibration Certificate (ISO 17025)
9797
Power Calibration (0-20KW AC and DC)
9113
Extended Certificate (UKAS - ISO 17025)
5065
6.5 Digit Bench Multimeter (external)
9085
Carry Case
www.timeeusa.com
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
77
78
5051 Calibration System
Time Electronics
Calibration, Test & Measurement










0 - 1050 V AC/DC voltage
0 - 22 A AC/DC current
Internal 6.5 Digit DMM
0 - 1GΩ resistance
Thermocouple simulation
Digital Frequency
Oscilloscope Calibration
Capacitance & Inductance
Clamp Meter Calibration
Touch Screen
The 5051 is a high performance multi product calibrator combining both source & measure functions.
It provides a wide range of calibrated outputs for AC/DC voltage and AC/DC current, plus a range of
resistance, capacitance, inductance, and frequency functions. An option for calibrating oscilloscopes
is also available. The integral DMM can measure DC voltages to 1000V, AC voltages to 750V,
resistance to 100Mohms, and frequency to 300 kHz.
The embedded operating system runs on a 2GHz PC based system which allows standard
peripherals to be connected. The control software allows the wide range of functions to be easily
selected using mouse, keyboard, or touch screen.
The standard 5051 can calibrate, bench and handheld multi-meters, frequency meters, ohm meters,
ac/dc millivoltmeters, resistance boxes, thermocouple indicators/sensors etc. With 5051 options
added, clamp meters, RTDs, power supplies, signal generators, ac/dc signal sources, timer counters,
oscilloscopes. Fully transportable, the 5051 is ideal for site or laboratory work.
The 5051Plus includes a comprehensive package of options
and provides a lab ready solution. It comes equipped with
every item required for a complete calibration station:
DMM; Scope Calibration; Capacitance and Inductance;
Full Range Resistance; Clamp Meter Adaptor; Touch Screen;
Test Lead Set; EasyCal; Factory Calibration Certificate;
Carry Case; Printer & Connectivity Kit (As Shown).
A suite of calibration programs that simplify and speed up calibration.
If you have an instrument that needs calibrating against specification
and the results stored and printed, EasyCal is the answer.
Calibration certificates and reports to ISO 9001 quality standards can
be produced, along with re-cal reminders, job sheets and calibration
labels. Data can be transferred to desktop PCs/servers using USB
memory or connected to a LAN via the Ethernet connection located
on the rear of the unit.
www.timeeusa.com
78
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
79
5051 Technical Specifications
Voltage DC
Range:
Best 1 Year Specification:
0 to ± 1050V
± 15ppm of setting
Current DC
Range:
Best 1 Year Specification:
0 to ± 22A
± 80ppm of setting
Voltage AC
Range:
Best 1 Year Specification:
1mV to 1050V (10Hz to 20kHz, Sine-wave)
± 300ppm of setting
Current AC
Range:
Best 1 Year Specification:
10uA to 22A (20Hz to 1kHz, Sine-wave)
± 0.05% of setting
Resistance
Range:
Best 1 Year Specification:
1Ω to 1GΩ (Fixed Values, decade steps)
± 20ppm of setting
Conductance
Range:
Best 1 Year Specification:
1 S to 1n S (Fixed Values, decade steps)
± 20ppm of setting
Thermocouple
Simulation
Range:
Best 1 Year Specification:
-270 to 1800°C (Type J,K,R,T,S,B,E,N)
± 0.15 °C
10MHz Digital
Frequency/Period
Range:
Best 1 Year Specification:
0.1Hz to 10MHz / 100nS to 10S
± 20ppm of setting
DMM 6.5 Digit
AC Volts: 0 - 750V
DC Volts: 0 - 1kV
AC Current: 0 - 3A
DC Current: 0 - 3A.
Resistance: 0 - 100MΩ
Frequency: 3Hz to 300kHz
Best 1 year spec: 0.06% of rdg + 0.04% of rng
Best 1 year spec: 35ppm of rdg + 6ppm of rng
Best 1 year spec: 0.1% of rdg + 0.04% of rng
Best 1 year spec: 500ppm of rdg + 50ppm of rng
Best 1 year spec: 100ppm of rdg + 50ppm of rng
Best 1 year spec: 0.01% of rdg
Hi Frequency AC V
Range/Max Freq:
Best 1 Year Specification:
20 to 200mV/300kHz. 0.2 to 2V/1MHz. 2 to 20V/100kHz
0.05% + 0.1mV
Capacitance
Values:
Best 1 Year Specification:
1nF,10nF,100nF,1uF,10uF & 100uF (100V Max)
± 0.25%
Inductance
Values:
Best 1 Year Specification:
1, 1.9, 5, 10, 19, 50, 100, 190, 500mH - 1H & 10H
± 0.1%
Full Range Resistance
Range:
Best 1 Year Specification:
1 to 120MΩ (Variable)
± 100ppm of setting
PT100
Range:
Best 1 Year Specification:
-200 to 850°C
± 0.2 °C
Oscilloscope
Frequency/Period
Range:
Best 1 Year Specification:
0.1Hz to 100MHz / 100ns to 10s
± 0.1ppm of setting
Values:
3 frequencies, 100Hz, 1kHz, 10kHz. Settable from 0 to 100%
Range:
Best 1 Year Specification:
0mV to 200V & 0mV to 2V 50Ω (Square-wave)
± 0.05%
Options
Oscilloscope Duty Cycle
Oscilloscope
Amplitude
Oscilloscope Fast-Rise
Values:
< 300ps. Bandwidth Checking up to 600 MHz
2.2 GHz Sweep
Range:
Best 1 Year Specification:
100MHz - 2.2GHz levelled sine-wave (0.5, 1, 1Vpk-pk).
Amplitude ± 1%, Frequency ± 20ppm.
Remote Pressure Module
Range:
Best 1 Year Specification:
0.2, 2, 5, 10, or 20 bar (specified on ordering)
0.04% of range +/- 1 digit (0.2 bar, 0.1% of range +/- 1 digit)
General Specification
Warm up: 1 Hour to full accuracy. Settling Time: Less than 5 seconds. Interfaces: 4 x USB. Display: 10.5” Colour LCD.
Operating Temperature: 15 - 25 °C, Full Spec: 22 °C +/- 3°C, Storage: -10 °C to 50 °C
Operating Humidity: < 80% non condensing. Altitude 0 - 3km. Non Operating 3Km - 12km
Line Power: 100 - 230V AC 50/60 Hz. 200W max.
Dimensions: W 17, D 21, H 8” (430, 538, 202mm). Weight: 51 lbs (23Kg)
Ordering Information
Code
Description
Code
Description
9798
Capacitance and Inductance*
7042
Remote Pressure Module
9787
Full Range Resistance & PT100*
9760
Power Amplifier
9770
Oscilloscope Calibration*
9082
Carry Case*
9769
2.2 GHz Sweep
9794
USB to GPIB Interface
9790
100A Current Option
9795
Printer and Connectivity Kit*
9780
Clamp Meter Adaptor 1 and 50 Turns*
9747
EasyCal Software*
9773
Optical Tachometer Calibration Adaptor
9796
Test Lead Set*
9767
External Low Noise Attenuator
9165
Factory Calibration Certificate *
9771
High Frequency AC Voltage
9134
UKAS/NIST (ISO 17025) Calibration Certificate
*Options included in 5051 PLUS package
www.timeeusa.com
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
79
80
Multifunction Calibrator Extras
Time Electronics
Calibration, Test & Measurement
In addition to internal options Time Electronics offer a selection of external extras for specific applications,
connectivity, and general use.
9780 - Clamp Meter Adaptor








Twin coils fitted as standard
Ratios 1:1 and 50:1
Primary current up to 22A
Simulated current up to 1100A
AC or DC
Frequency up to 90Hz
Max drive voltage 3V
Low resistance test leads included
9773 - Optical Tacho Adaptor

Compatible with 5051 and 5025

0.01 % Accuracy

EasyCal Software Compatible
9796 - 10 piece Test Lead Set









Pair of Hi Voltage Leads (1.5kV)
Pair of Hi Current Leads (30A)
4 Wire Screened Test Leads
Pair of Low Thermal Test Leads
BNC to 4mm Adaptor
4mm Test Lead Couplers
Pair of 4mm to Spade Adaptors
Pair of 4mm Test Clips
Test Lead Holder
7042 - Remote Pressure Module

Compatible with 5051 Multifunction Calibrator

Vacuum, 0.2, 2, 5, 10, 20 bar options

Pressure/Vacuum calibration 0.04% accuracy

PC Software Included

USB powered
Also available:
EasyCal Software, 19" Rack Mount Kit, 5 piece test lead set, Printer Kits (Standard and Label/ID), Bar Code
Reader, Carry Muffs, Current Transformer, Power Amplifier, Adaptors for USB/GPIB/RS232.
www.timeeusa.com
80
Tel: 516-723-9909
MULTIFUNCTION CALIBRATORS
Email: [email protected]
81
Calibration Software
Time Electronics' Easycal Calibration software is the ultimate addition to any
calibration process, with easy to operate features that make instrument calibration
faster and more reliable. This comprehensive suite of programs combines a user
friendly interface with TE technologies to improve the way you automate calibration
procedures. Easycal operates with all Time Electronics' programmable instruments
and calibrators.
EasyCal Software .............................................................................................................................. 82
Introduction ....................................................................................................................................... 83
EasyCal Overview ............................................................................................................................. 84
Example Certificates and Reports ................................................................................................... 88
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION SOFTWARE
Email: [email protected]
81
82
EasyCal Calibration Software
The comprehensive solution to calibration management
laboratory

site

office
Calibrate electrical, mechanical,
pressure and temperature devices
Network Compatible
Automated Calibration Run
ID Label Printing
Calibration Label Printing
Customise reports and certificates
E-mail Reminder Letters
Bar Codes
Instrument Control GPIB/RS232/USB
Generate PDF reports & certificates
Calibration Due Reminder System
Over 1000 Standard Calibration
Procedures Included
For windows 2000, xp, and vista
www.timeeusa.com
82
Tel: 516-723-9909
CALIBRATION SOFTWARE
Email: [email protected]
83
Introduction
For laboratory, office and site calibration work, EasyCal is the ideal solution.
Automating the calibration process brings important benefits and provides increased speed of calibration and
consistency of results. Calibration certificates and reports are produced easily to ISO 9001, ISO 17025, and
UKAS quality standards. EasyCal also simplifies the administration process from reminder reports, through to
despatch.
EasyCal Networking
With networking capabilities a multi-user installation can be implemented.
Office stations can keep track of job information, produce reminder reports and issue certificates.
Laboratory stations perform the actual calibration, enter any ‘on going’ job information, create or edit test
procedures and issue certificates.
Management can over-see the complete operation. Keep track of calibration standards and instruments. Create
and update uncertainty information. View and issue reports and certificates. Control user access and monitor job
progress. Create, edit and sign off test procedures. With the ability to ‘simulate’ calibration runs procedures can
be tested without the need for the calibrating instrument or unit under test.
Site calibration is also controlled by EasyCal. The required information for a site job is transferred to a laptop or
5051 calibration system. Alternatively ‘calibration test forms’ can be produced for hand written entry. The data is
imported to the central servers’ database or entered into EasyCal back at base.
EasyCal Features
Networking:
For multi-station and site calibration work
Licensing:
Portable, only required for calibration runs
Instrument Control:
Control and communicate with any RS232/USB/GPIB instrument
TE Instrument Support:
Time 5025, 5051, 5075. 5018, 5011 and more
GPIB Support:
NI, Agilent, Measurement Computing, CEC
Security:
Secure User Log In and Digital Signatures
Crystal Reports:
Edit certificate and report templates. Create custom reports
Uncertainty Management:
Create uncertainty tables for Laboratory and Site
Built –in PDF engine:
Produce PDF certificates and reports without 3rd party software
Data export:
To CSV and HTML formats.
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION SOFTWARE
Email: [email protected]
83
84
EasyCal Overview
Instruments, Customers, and Jobs
A comprehensive database of instruments and customers (or owner) allows the operator to access any
information required. By clicking the search button on the toolbar it is possible to enter specific criteria to
quickly find the instrument or customer. When adding details the user is aided by comprehensive drop-down
lists, which automatically update when a new detail is added. When an instrument is booked in the job process
starts. Specific information about the job is entered; such as ‘service required’, ‘service by’ and ‘accessories
supplied’. A job sheet and label can be produced at this stage to accompany the instrument. As the job is put
though the system these parameters can be updated for example ‘quote price’, ‘job status’ and ‘invoiced’.
Instrument Recall and Reminder System
Instruments which are due for calibration are listed on screen. From here reminder letters and lists can be
printed or emailed directly to the customer or department.
Calibrating Instruments, Standards and Uncertainties
Traceability information on calibrating instruments and standards is stored and maintained by EasyCal.
Uncertainty tables for laboratory and site can be created for each calibrating instrument. These are then
automatically processed and applied to certificates.
www.timeeusa.com
84
Tel: 516-723-9909
CALIBRATION SOFTWARE
Email: [email protected]
85
EasyCal Overview
Procedure Writing and Editing
Creating and editing test procedures is made simple with intuitive, user-friendly windows. Editing test
information can be done by replacing, adding, or copy/pasting. EasyCal keeps track of each time a procedure
is edited.
Standard Procedures
A standard calibration library comprising of over 1000 procedures covering a wide
variety of instruments is included as standard. Procedure templates for multi-meters,
clamp meters, decade boxes, insulation testers, and more can be used for creating any
new procedures as required.
Conversion Tables
Conversion tables for thermocouples and RTDs are included; alternatively user-defined tables can be created.
RS232 / GPIB Commands
For more complex instrument control GPIB / RS232 commands can be sent on a test-by-test basis or run as a
script.
Procedure Reports
Procedure reports are available for approval and signing off.
Procedure Simulation
To help with the development of procedures a test can be edited while a calibration run is being performed.
Also the Calibration Run Simulator means a procedure can be tested without the need for controlling an
instrument.
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION SOFTWARE
Email: [email protected]
85
86
EasyCal Overview
Instrument Calibration
Selection of the instrument under test is quick and easy. With the use of a barcode scanner this selection
becomes automatic.
Calibration Prompts
Picture prompts are shown to aid the user with instrument range selection and connection.
Test Control
At any stage during the calibration run a summary of the results for the tests completed is displayed. The
operator is able to move forward or backward through the procedure as required. A summary printout is also
available from Test Control.
Graphical Test Screen
The calibration run is made simple and efficient by a graphical user-interface, which increases speed of data
entry. Instruments, which cannot be automatically calibrated, can still have the results data entered manually.
The entered value is compared with the required value as specified in the procedure.
End of Calibration Run
At the end of a calibration run the operator has the option to print a certificate and label. The ability to edit
service information is also presented to the operator.
Calibration Test Forms
Alternatively ‘calibration test forms’ for hand written results are available. This data is then entered into
EasyCal at a later date.
www.timeeusa.com
86
Tel: 516-723-9909
CALIBRATION SOFTWARE
Email: [email protected]
87
EasyCal Overview
Certificates
Produce Calibration Certificates & labels on demand. The user can keep a record of instrument history and
servicing. Simple search facilities help find the required certificate.
Customise Certificates
Using Crystal Reports (optional) certificates formats can be easily customised, or design a new certificate
layout.
Import and Export Results
Data can be exchanged from one system to another user via the import and export features.
Certificate data can be converted in spreadsheet, CSV and HTML formats.
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION SOFTWARE
Email: [email protected]
87
88
Example Reports and Certificates
Certificates
Job Sheet and Labels
www.timeeusa.com
88
Tel: 516-723-9909
CALIBRATION SOFTWARE
Email: [email protected]
89
Process Control Equipment
Time Electronics manufacture a complete range of process control equipment,
designed for pressure calibration, temperature calibration, and loop signal calibration.
These well-proven precision test instruments cover the requirements of the process
industry.
TEMPERATURE
1090 Handheld Temperature and Process Calibrator ......................................................................... 90
7000 Handheld RTD Temperature Calibrator ..................................................................................... 92
7050 Process and Thermocouple Calibrator ....................................................................................... 94
5011 Resistance/Temperature Calibrator ........................................................................................... 96
1067 Precision Decade Box (PT100 Simulation) ................................................................................ 98
1049 Handheld PT100 Simulator Handheld (Class A °C) ................................................................... 99
PRESSURE
7040 Handheld Digital Pressure Calibrator ....................................................................................... 100
7010 Transportable Pressure Calibrator (Single Channel) ............................................................... 102
7015 Transportable Pressure Calibrator (Dual Channel) .................................................................. 104
7016 Transportable Pressure Calibrator (Single Channel with Regulator) ....................................... 106
7018 Transportable Differential Pressure Calibrator ......................................................................... 108
7090 Vacuum & Pressure Calibration Pump (-950mbar to 40bar) .................................................... 110
7095 Hydraulic Pressure Calibration Pump (0 to 700bar) ................................................................. 111
LOOP
1048 Handheld V-I Loop Calibrator (0.02% Accuracy) ..................................................................... 112
1077 Handheld Milliamp Transducer/Line Simulator (Transim) ........................................................ 114
7005 Handheld Loop Calibrator ........................................................................................................ 116
7006/7007 Loop-Mates 1 and 2 (Handheld Simulator & Indicator) ................................................... 118
Also see:
Resistance Decade Boxes for portable PT100/RTD/PRT on page 38.
Multifunction Calibrators with temperature/pressure/loop capabilities on page 67.
TE CalBench for the complete process control system on page 119.
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
89
90
1090 Temperature and Process Calibrator
Time Electronics
Calibration, Test & Measurement











Measure/Simulate 8 thermocouples
Measure/Simulate PT100
ITS 90 standard
Measure/Source (uV/mV/mA)
Display in °C and °F
Automatic CJC - selectable
10 point memory recall
Inching and Step functions
Mains/Battery + auto power down
Process loops 4-20mA and 0-50mA
24V loop drive voltage
The 1090 is a portable high performance process calibrator that combines source and measurement functions
for thermocouples, PT100s, uV, mV, and mA.
Thermocouple measurement and simulation
The unit can measure and simulate the temperature and mV characteristics of J, K, T, R, S, B, N and E
thermocouples.
Cold junction compensation
The unit can be operated with or without internal cold junction compensation.
PT100 measurement and simulation
Based on 0.3850 alpha probe standard.
Range is –200 °C to 700 °C.
Measurement and Source (uV, mV, and mA)
Measurement ranges are 0 to +/-30mV and 0 to +/-60mA.
Source ranges are 0 to +/-80mV and 0 to +80mA.
Temperature units selection
The display can be easily changed from °C to °F. The equivalent uV (thermocouples) and ohms (PT100) can
also be shown.
24V Process Loop drive mode
A process loop can be driven at 24V and up to 60mA by selecting the ‘Milliamp Source’ mode and setting it at
60mA (or a lower level if required).
Inching (Incrementing/Decrementing)
The unit has a general-purpose inching function. This adjusts the output in fixed increments of temperature
(thermocouples only) or voltage or current. The set-up menu gives a the user a choice of three levels of
increment i.e. 0.1, 1 or 10 for °C/°F, or 1, 10, or 100 uV/uA for voltage/current. The lowest of these represents
the highest setting resolution and provides the most precise control of the output. This is especially useful for
calibrating thermostat controllers that have tight specification on hysteresis.
Memory recall and step/auto-step functions
Up to 10 values can be stored in the unit’s non- volatile memory and they can be recalled at any time. The user
can also manually step through them in sequence using the step key. Continuous stepping (auto-step) is also
available at any user selectable rate between 1 and 10 seconds/step.
Power is via an internal high capacity re-chargeable metal hydride battery that can be re-charged from an
external mains charger (supplied as standard). The unit is supplied in a robust case with a carrying strap. A
pocket for the instruction manual is provided.
www.timeeusa.com
90
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
91
1090 Technical Specifications
MEASURE ACCURACY
SIMULATE ACCURACY
THERMOCOUPLE
TYPE
TEMPERATURE
RANGE °C
ACCURACY
°C
THERMOCOUPLE
TYPE
TEMPERATURE
RANGE °C
ACCURACY
°C
J
-200 to 580
0.7
J
-210 to 150
150 to 1200
0.15
0.3
K
-200 to –150
-150 to 750
2.5
0.5
K
-270 to 190
190 to 1250
0.5
0.4
T
-200 to 0
0 to 400
1.5
0.4
T
-200 to 150
150 to 400
0.4
0.5
R
-50 to 400
400 to 1750
3.0
1.5
R
-50 to 800
800 to 1750
0.8
2.0
S
-50 to 100
100 to 1750
3.0
1.5
S
-50 to 850
850 to 1750
0.9
2.0
B
110 to 1000
1000 to 1800
3.5
1.5
B
100 to 1200
1200 to 1800
2.0
3.0
N
-100 to 890
0.6
N
-270 to 260
260 to 1300
0.5
1.0
E
-50 to 400
0.4
E
-50 to 1000
0.3
Resolution: 0.1 °C or °F
Resolution: 0.1 °C or °F
An additional correction representing the equivalent 1µV should be allowed for stray thermal emf effects.
Cold Junction Compensation:
Operating Temperature:
Connections:
Power:
Accuracy 0.2 °C. Resolution 0.1 °C.
-10 to 40 °C (15 to 105 °F)
Industry standard 4mm screw terminals.
A metal hydride rechargeable battery pack gives approximately 60 hours continuous
operation. The mains re-charger supplied allows full recharge in 11 hours. To
conserve battery life, a user inactivity power-down feature is included.
Millivolt Source 0 to +/- 80mV
Accuracy (8 to 80mV):
0.02% of f.s.
Resolution (8 to 80mV):
5uV
Accuracy (0 to 8mV):
+/-4uV
Resolution (0 to 8mV):
0.5uV
Output resistance :
10 ohm
Milliamp Source 0 to +80mA
Accuracy (8 to 80mA):
0.02% of f.s.
Resolution:
5uA
PT100 Simulation
Accuracy (0 to 8mA):
+/-10uA
14 set temp. points: -100, -50, -20, 0, 20, 50, 100, 200, 300, Resolution:
0.5uA
400, 500, 600, 700, 800 °C
Max load (24V drive): 300R/80mA ,480R/50mA ,1.2K/20mA
Accuracy:
0.1% of resistance value (typically 0.5 °C) Inching
Three levels of increment, 0.1, 1 or 10 for °C/°F, and 1, 10,
PT100 Measure (0.2 °C or °F resolution)
or 100 uV/ uA for voltage/current. The lowest of these
Range:
-200 to 700 °C, 2 wire.
represents the highest setting resolution and provides the
Accuracy:
0.2% of resistance value (typically 0.7 °C)
most precise control of the output.
24V Process Loop drive mode
A process loop can be driven at 24V and up to 60mA by
Memory recall and step functions
selecting the ‘Milliamp Source’ mode and setting it at 60mA
10 memory locations for non-volatile storage of values.
Manual and Auto-Step, rate adjustable from 1 to 10 sec/step (or a lower level if required).
Millivolt Measure 0 to +/- 30mV
Resolution:
10µV
Accuracy:
0.05% of f.s. ±1 digit
Input resistance:
100K Ohms
Milliamp Measure 0 to +/- 60mA
Resolution:
20µA
Accuracy:
0.05% of f.s. ±1 digit
Input resistance:
0.5 ohms
General Specification
Dimensions:
Weight:
Optional Extras:
9.25 x 6 x 3” (235 x 150 x 75 mm).
2.8lbs (1.25 Kg)
Calibration Certificates
Ordering Information
Code
Description
1090
Temperature and Process Calibrator (including batteries, charger and carrying case)
9177
Factory Calibration Certificate
9139
UKAS/NIST Traceable Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
91
92
7000 RTD Temperature Calibrator
Time Electronics
Calibration, Test & Measurement

Temperature: Accuracy 0.05 °C (0.09 °F)
Resolution 0.01 °C (0.02 °F)

Resistance:

2, 3 and 4 Wire Connections

Read and Simulate °C, °F, °K, and Ohms

Ramp & Step

PT100 plus 7 other RTD types

User programmable

Supplied in protective carrying case
Accuracy 0.03Ω
Resolution 0.01Ω
The 7000 is a portable process control instrument that combines a precision Digital Thermometer (using RTD
probes) with an RTD/Ohms Calibrator.
Compact and easy to use, it solves the problem of making high accuracy temperature measurements without
using bulky mains powered instrumentation.
Powered from internal long life re-chargeable batteries or an external mains adapter, it is equally valuable in
laboratory, workshop or the field. It can also be used as an external temperature reference for dry block and
other precision temperature baths.
7000 Technical Specifications
MONITOR MODE (4 WIRE) FUNCTIONS
SIMULATOR MODE (4 WIRE) FUNCTIONS
1. Check RTD probes by measuring their resistance
at known temperatures.
2. Measure resistance values.
1. Output resistance of precise known value.
3. Indicate temperature when connected to an RTD
probe.
4. Can be pre-programmed with a particular RTD’s
characteristics to allow very high accuracy.
Excitation current:
Resistance range:
Resolution:
Accuracy:
Auto re-calibration:
Temperature stability:
Max/Min values:
1mA on all ranges
0.01Ω to 2.6kΩ
0.01Ω
See tables below
Every 0.6 secs.
Better than 0.0015%/°C
Logged automatically
The 7000 may be used with a calibrated and certified
probe to produce a highly accurate thermometer.
The performance can be further enhanced by
programming the actual characteristic of the probe
into the unit.
www.timeeusa.com
92
2. Simulate an RTD value from an RTD table chart.
3. Simulate an RTD value using the internal table.
Excitation current:
Resistance range:
Resolution:
Accuracy:
Auto re-calibration:
Temperature stability:
0.6mA to 1mA.
0.01 to 2.6kΩ
0.01Ω
See tables below
Every 0.6 secs
Better than 0.0015%/°C.
Enhanced performance may be achieved by
programming the unit to simulate the characteristic of
a particular probe.
Five fixed step points (0, 25, 50, 75, 100%) are
available between a user set minimum (0%) and a
maximum (100%). Programmable ramp function is
also available.
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
93
Standard RTD types (Non standard RTD types user programmable)
Element
Alpha Coeff.
Celsius
Range
Accuracy
-200 to 250
0.05 °C
250 to 849
0.07 °C
Fahrenheit
Range
Accuracy
-330 to 480
0.10 °F
480 to 1560
0.14 °F
Pt100 DIN
0.003850
Pt100 US
0.003916
-100 to 250
250 to 457
0.05 °C
0.07 °C
-150 to 480
480 to 850
0.10 °F
0.14 °F
Pt200 DIN
0.003850
-200 to 300
0.05 °C
-330 to 570
0.10 °F
Pt500 DIN
0.003850
-200 to 250
250 to 630
0.05 °C
0.07 °C
-330 to 480
480 to 1160
0.10 °F
0.14 °F
Pt1000 DIN
0.003850
-200 to 250
250 to 630
0.05 °C
0.07 °C
-330 to 480
480 to 1160
0.10 °F
0.014 °F
Ni 120
0.006180
-100 to 200
0.05 °C
-150 to 390
0.10 °F
Ni 1000
0.006180
-100 to 200
0.05 °C
-150 to 390
0.10 °F
Range ohms
20 to 400
400 to 800
800 to 1200
1200 to 2600
Monitor
0.03Ω
0.10Ω
0.20Ω
0.50Ω
Generator
0.03Ω
0.10Ω
0.20Ω
0.50Ω*
Resistance
Accuracy
*plus additional error of 0.05% of output value. If excitation current is less than 1mA.
General Specification
Operating temperature range:
–10 to 50oC
Battery power:
NiCad rechargeable
Mains power:
External mains adapter.
Battery life:
> 30hrs
Case:
Impact resistant ABS
Size:
6.5 x 3.5 x 1.8” (165 x 90 x 45 mm)
Weight:
0.9 lbs (0.40 kg)
Optional Extras:
Mains Adapter 230V AC, Mains Adapter 110V AC
Calibration Certificates
Ordering Information
Code
Description
7000
RTD Temperature Calibrator
7633
Mains Adapter 230V AC
7633
Mains Adapter 110V AC
9183
Factory Calibration Certificate
9194
NIST/UKAS Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
93
94
7050 Process and Thermocouple Calibrator
Time Electronics
Calibration, Test & Measurement
The 7050 Process Calibrator combines the essential functions of
measurement and simulation of volts, millivolts, milliamps, and ohms with the
direct readout simulation of thermocouples and RTD’s in °C or °F units.
The instrument is microprocessor based and housed in a rugged case
designed for use in the field. Input and Output functions are displayed
simultaneously and the switch controls allow for easy and precise operation.
Five calibration points are instantaneously accessible through a preset
percentage selector and all functions may be generated in a fully
programmable ramp format.
In addition to the standard calibration facilities the instrument may be used as
a signal converter. Any electronic input signal can be converted and output as
a proportional signal of 4-20mA, 0-5V or sq. root 4-20mA.
The 7050 is highly adaptable, IPT 68 and ITS 90 curves are accommodated
and non-standard thermocouples and RTD’s may be programmed on request.
Input
Voltage ranges
Range
40V
4V
400mV
40mV
Accuracy @ 23 °C
0.03%
0.03%
0.03%
0.03%
Resolution
Current ranges
Range
1mV
100µV
10µV
1µV
400mA
40mA
4-20mA/0-100%
Accuracy @ 23 °C
0.03%
0.03%
0.06%
Resolution
10·µA
1µA
.01%
Range (ohms)
40000
4000
400
Accuracy @ 23 °C
0.03%
0.03%
0.06%
Resolution (ohms)
1
0.1
0.01
Resistance ranges
Output
Voltage ranges
Range
-2..+10V
-100mV..+400mV
-10mV..+40mV
Accuracy @ 23 °C
0.06%
0.03%
0.03%
Resolution
1mV
10µV
1µV
Output Impedance:
< 10 Ω
< 10 Ω
< 10 Ω
Range
0.20mA
4.20mA
TX Sim (4..20mA)
Accuracy @ 23 °C
0.03%
0.03%
0.03%
Resolution
1µA
1µA
1µA
Current ranges
Max Load Resistance
900Ω at 20mA, Open circuit voltage 18- 27V
Resistance ranges
Range (ohms)
0 ……. 400Ω
Accuracy @ 23 °C
± 0.03%
Resolution (ohms)
0.01
Excitation Current
0.2 ….. 2mA
Other
Loop drive supply: Nominal 24V, current limit set to 30mA
www.timeeusa.com
94
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
95
Technical Data - Process Signal & Temperature Measurement & Simulation
Centigrade
Range
Accuracy
-210 to 0
± 0.4
0 to 710
± 0.2
710 to 1200
± 0.9
Fahrenheit
Range
-410 to 32
32 to 1310
1310 to 2192
K Nickel-Chrome/
Nickel-Aluminium
-270 to -240
-240 to -180
-180 to -50
-50 to 960
960 to 1370
± 3.0
± 1.2
± 0.5
± 0.3
± 1.7
-454 to -430
-430 to -292
-292 to -58
-58 to 1760
1760 to 2498
± 5.4
± 2.0
± 0.9
± 0.6
± 1.5
T Copper/Copper-Nickel
-270 to -250
-250 to -180
-180 to -100
-100 to 400
± 3.0
± 1.0
± 0.5
± 0.2
-454 to -418
-418 to -292
-292 to -148
-148 to 752
± 5.4
± 1.8
± 0.9
± 0.4
E Nickel-Chrome
Copper-Nickel
-230 to 0
0 to 540
540 to 1000
± 0.5
± 0.2
± 1.5
-382 to 32
32 to 1004
1004 to 1832
± 0.9
± 0.4
± 2.7
R Platinum 13%
Rhodium/Platinum
-50 to 0
0 to 70
70 to 400
400 to 1000
1000 to 1760
± 3.0
± 2.0
± 1.5
± 1.0
± 0.8
-58 to 32
32 to 158
158 to 752
752 to 1832
1832 to 3200
± 5.4
± 3.6
± 2.7
± 1.8
± 1.4
S Platinum 10%
Rhodium/Platinum
-50 to 0
0 to 100
100 to 450
450 to 1760
± 2.5
± 1.8
± 1.3
± 0.9
-58 to 32
32 to 212
212 to 842
842 to 3200
± 4.5
± 3.2
± 2.3
± 1.6
B Platinum 30% - Rhodium/
Platinum 6% - Rhodium
200 to 400
400 to 1000
1000 to 1820
± 5.0
± 2.0
± 1.0
392 to 752
752 to 1832
1832 to 3308
± 9.0
± 3.6
± 1.8
N Nickel-Chrome-Silicon/
Nickel-Silicon
0 to 330
330 to 1100
1100 to 1300
± 0.4
± 0.3
± 1.5
32 to 626
626 to 2012
2012 to 2372
± 0.7
± 0.5
± 2.7
RTD
Pt100
Range
-200 to 850
Accuracy
± 0.3
Range
-392 to1562
Accuracy
± 1.0
Thermocouple
J Iron/Copper-Nickel
Accuracy
± 0.7
± 0.4
± 1.0
Thermocouple : Linearisation to BS 4937. ITS 90 or IPTS68 Selectable
Pt100 : Linearisation to BS1904 (1984).DIN43760 (1980) Linearisation Accuracy 0.1% of reading for Class A, 38.5 Ω F.I
Excitation current : 0.5mA(Input), 200uA to 2mA(Output)
Cold Junction Compensation: External (Pt100), Internal, Ice point. Accuracy +/-0.2°C at 23°C
Ramp
Fully programmable continuous and stepped
Steps
5 Steps with fully adjustable zero
Transmitter
Tx function 4-20mA
Signal Converter
Any input to any output
Dual Readout
Measure and source simultaneously displayed
General Specification
Mains Power:
220/230V or 115/110V AC 50 or 60Hz
Stability:
100ppm per °C range 0 to 40°C
Battery:
Rechargeable NiMHd - Internal Charger
Displays:
LCD Dot Matrix, 1 line by 20 charx12mm, alphanumeric.
Case:
Impact resistant structural resin. Dimensions: 11 x 10 x 7” (273 x 248 x 178mm). Weight: 10 lbs (4.5Kg)
Ordering Information
Code
Description
7050
Process & Thermocouple Calibrator
9180
Factory Calibration Certificate
9192
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
95
96
5011 Resistance / Temperature Calibrator
Time Electronics
Calibration, Test & Measurement

1  to 120 M

RTD Simulation

Thermocouple Simulation

DCV & DCI Options

10MHz Frequency Option

RS232/GPIB/USB

Front Panel Operation
The 5011 is primarily a programmable resistance / RTD source. With the ability to add DC Voltage,
Thermocouple Simulation and DC Current the 5011 is truly a versatile temperature calibrator.
High performance resistance of is offered as standard with an accuracy of 0.01% and 1mΩ resolution
from 50Ω to 1kΩ.
Simple front panel operation allows the user to quickly set the function and output required.
Using the jog / shuttle dial deviation the user can finely adjust the output value as a percentage (+/9.99%). All this information is shown on a clear, easy to read LED display.
As standard the 5011 uses a SCPI command structure for programming. The 5011 also supports the
older 9811/19/20 command set making it an ideal replacement for these models.
The DCV / Thermocouple option provides a DC voltage source (+/- 20V) and simulates thermocouple
types K, J, T, R, S, N, E and B.
A DC Current option is available which sources up to 220mA. This makes the 5011 ideal for accurate
process control calibration.
A 0.1 Hz to 10 MHz frequency (Period 100nS to 10s) option is also available. The output is variable
with a best resolution setting of 0.1Hz.
Calibration Made Easy
Connect the 5011 to a PC/Laptop (via RS232, GPIB or USB) installed with Time Electronics EasyCal
and automate the calibration process. Increase speed of calibration and consistency of results;
produce calibration certificates and reports to ISO 9001 quality standards.
www.timeeusa.com
96
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
97
5011 Technical Specifications
Accuracies quoted are for 1 year.
THERMOCOUPLE SIMULATION
RESISTANCE
Range
Accuracy
Resolution
Type
Range ºC
Acc. ºC
-210 to 150 / 150 to 1200
0.15 / 0.3
1Ω – 20Ω
0.01% +/- 5mΩ
1Ω
J
20Ω – 99.999Ω
0.01% +/- 5mΩ
1mΩ/5mΩ*
K
-270 to 190 / 190 to 1250
0.5 / 0.6
1mΩ
T
-200 to 150 / 150 to 400
0.4 / 0.5
-50 to 800 / 800 to 1750
0.8 / 2.0
100Ω – 999.999Ω
0.01% +/- 5mΩ
1kΩ – 9.999kΩ
0.02% +/- 20mΩ
1Ω
R
10kΩ – 99.999kΩ
0.01% +/- 1Ω
1Ω
S
-50 to 850 / 850 to 1750
0.9 / 2.0
B
100 to 1200 / 1200 to 1800
1.0 / 2.0
N
-270 to 260 / 260 to 1300
0.5 / 0.4
E
-50 to 1000
0.3
100kΩ – 999.99kΩ
0.01% +/- 10Ω
10Ω
1MΩ – 9.9999MΩ
0.02% +/- 100Ω
100Ω
10MΩ – 120MΩ
0.1% +/- 1kΩ
1kΩ
Temp Coefficient:
Power Rating:
Maximum Voltage:
Resistance Switch Time:
Operation Time:
End Resistance Variation:
Cold Junction Compensation +/- 0.5ºC (applies to ambient
changes of less than +/- 1ºC at 23 ºC)
less than 50 ppm per ºC
0.1 Watt per resistor
250 V
< 250us
< 300ms
< 2.5mΩ
The accuracy of the thermocouple simulation is determined by the
accuracy of the 5011’s DC Voltage function and the accuracy of
the standard thermocouple tables (BS EN 60584-1) published by
the British Standards Institute.
The 5011 uses precise digital interpretation of the tables to output
voltage levels that are within the accuracies specified in the table.
*Output Setting Resolution below 50Ω is 5mΩ
DC VOLTAGE
PRT SIMULATION
RTD Type
Alpha Coeff
Range
Accuracy
Pt100
0.003850
-180 to -100ºC
0.1ºC
Pt100
0.003850
-100 to 850ºC
0.05ºC
It should be noted that the accuracy of the PRT simulation is
determined by the accuracy of the PRT tables (BS EN 60751)
published by the British Standards Institute. The 5011 uses precise
digital interpretation of the tables to output resistance values that are
within the accuracies specified in the table.
Range
Accuracy
Resolution
20mV
100ppm + 4uV
100nV
200mV
30ppm + 6uV
1uV
2V
25ppm + 20uV
1uV
20V
25ppm + 150uV
10uV
DC CURRENT (Compliance Voltage: 11V)
Range
220uA
2.2mA
22mA
220mA
FREQUENCY / PERIOD (2V pk/pk approx)
0.1Hz to 10MHz / 100nS to 10s Accuracy 20ppm
Accuracy
150ppm + 15nA
100ppm + 40nA
80ppm + 200nA
80ppm + 3uA
Resolution
1 nA
10 nA
10 nA
100 nA
General Specification
Power:
110 V to 240 V AC 50/60 Hz. 30 VA
Operating Temperatures:
0-45 ºC. 22 ºC +/- 3 ºC for full specification.
Dimensions:
Weight:
Optional Extras:
W 18 x D 11 x H 7 “ (W 450 x D 272 x H 152 mm).
15.4lbs (7 Kg)
DC Voltage and Thermocouple Simulation, DC Current, 10MHz Frequency.
Factory or UKAS/NIST Calibration Certificates
Rack Mount Kit
Ordering Information
Code
Description
5011
Resistance / Temperature Calibrator
9711
DC Voltage and Thermocouple Simulation
9718
DC Current 220mA (Only available if 9711 DC Voltage option fitted)
9729
Frequency Option (10MHz digital)
9728
Rack Mount Kit
9115
UKAS/NIST Calibration Certificate (ISO 17025)
9171
Factory Calibration Certificate
9747
EasyCal Calibration Software
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
97
98
1067 Precision Decade Resistance Box
Time Electronics
Calibration, Test & Measurement

Precision PT100 Simulation

0.01% Accuracy

10m – 12k

6 Digit Resolution

Better than 20ppm/year stability
The 1067 precision decade resistance box is suitable for a wide range of simulation work. It is particularly
suitable for simulating and calibrating precision PT100 sensors and temperature indicators/meters that use
resistive sensors.
Special care has been taken in the construction of the 1067 to ensure that the residual end resistance is as low
and as stable as possible. Multiple self-wiping silver alloy contacts are used for each position to ensure
outstanding performance and long life.
Housed in a robust metal case the 1067 is fully screened and low thermal emf terminals are used.
The switch dials have clear markings and in an easy to read in-line format. Each decade is scaled from 0 to 11
and therefore allows convenient overlap of the set values. The maximum value settable is 12,222.21 ohms.
1067 Technical Specifications
Resistance range:
10m to 12k
Number of decades:
6, each decade settable from 0 – 11
Increments:
10m steps
Accuracy:
At calibration temperature of 22 °C. +/- 0.01% of setting +/- 2m, after
deduction of residual end resistance +/- 1m for residual variation.
Current rating:
10m range: 3A, 100m range: 2A, 1 range: 600mA
10 range: 200mA, 100 range: 60mA, 1k range: 20mA
Residual end resistance:
Less than 10m. Less than 1m variation
Temperature coefficient:
Less than 10 ppm per °C (> 1). Less than 20 ppm per °C (< 1)
Maximum voltage:
200V at maximum resistance setting
Insulation:
Case to resistance terminals 2kV / 50Hz max
Operating torque:
Less than 0.1 Nm
Stability:
Better than 20 ppm per year (>1) Better than 100 ppm per year (<1)
Contacts:
Make before break – Silver alloy
General Specification
Dimensions:
3.5 x 2.5 x 14” (87 x 63 x 355mm)
Weight:
2.4lbs (1.1kg)
Supplied with:
2 year warranty, test leads, and factory certificate
Optional Extras:
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
1067
9114
Description
Precision Decade Resistance Box
UKAS/NIST Traceable Calibration Certificate
www.timeeusa.com
98
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
99
1049 Class A °C PT100 Simulator
Time Electronics
Calibration, Test & Measurement

-200°C to + 800°C

± 0.3°C accuracy

Based on ITS 90 EN60751

23 set points

Exceeds Class A

Good temperature stability

Passive resistance source
The 1049 is a portable precision simulator for PT100 0.3850 platinum resistance elements used for accurate
temperature measurement.
It follows the PT100 scale from –200°C to +800°C with 23 set points. High performance metal film resistors are
used throughout which ensures a good temperature coefficient and long term stability.
The specification is in accordance with DIN EN 60751 (ITS 90). Offering high accuracy across the full operating
range of PT100 devices it exceeds the performance of Class A & B. The 1049 will be of particular interest to
those operating in the –60 to +60°C range where a performance exceeding Class A (e.g. better than +/- 0.15°C
at 0°C), is required.
Since the 1049’s output is a purely passive resistance it will operate with all types of PT100 measuring
equipment including the live systems using pulsed, or interrupted excitation current.
1049 Technical Specifications
Set points °C:
-200, -100, -50, -20, -10, 0, 10, 20, 30, 40, 50, 60, 80,
100, 150, 200, 250, 300, 400, 500, 600, 700, 800.
Accuracy:
-200 to -100°C ± 0.3°C
-50 to +60°C ± 0.15°C
+80 to +200°C ± 0.3°C
+250 to +500°C +/- 0.5°C
+600 to +800°C +/- 0.65°C
Temp Coefficient:
Less than 30 ppm per °C
Maximum Current:
50 mA
General Specification
Dimensions:
2.4 x 5 x 2.2“ (61 x 112 x 55 mm)
Weight:
0.4lb (170g)
Supplied with:
2 year warranty, test leads, factory certificate, and leather carry pouch
Optional Extras:
UKAS/NIST Traceable Calibration Certificate
Ordering Information
Code
1049
9114
Description
Handheld PT100 °C Simulator
UKAS/NIST Traceable Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
99
100
7040 Digital Pressure Calibrator
Time Electronics
Calibration, Test & Measurement
 0.2, 2, 5, 10, 20 bar options
 Pressure/Vacuum calibration 0.04% accuracy
 Loop current calibration
 9 engineering units - bar, psi, KPa, inWg,
cmWg, inHg, mmHg, Kg/cm2, Atm
 Min / Max function
 Leak rate function
 4.5 digit display
 9V internal battery
 RS232 serial interface
Options:
40 bar pneumatic hand pump
Calibration Software
The 7040 is a portable pressure calibrator suitable for workshop, laboratory and field use.
Pressure can be displayed in any of nine popular engineering units. Loop current can also be
displayed in mA, or as a percentage of span (4-20mA).
A min/max logging function (pressure or loop current) is provided. The min or max values
can be recalled to the display and if required can be viewed in real time.
An additional feature is leak rate display. This allows the actual leakage rate to be observed
in real time in the selected ‘pressure units’ per sec, or per min.
Using a PC or laptop computer and a suitable program the 7040’s displayed parameters can
be read back – Pressure, Loop Current, Max Value, Min Value. By arranging for the
program to store these values in a database a full data logging function is available.
Alternatively, by using a calibration software package such as Time Electronics’ EasyCal,
pre-written calibration procedures can be executed and the results recorded automatically.
Calibration certificates can then be printed on site or back at the lab as required.
www.timeeusa.com
100
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
101
7040 Technical Specifications
Pressure Calibration
Pressure Range:
Vacuum:
Accuracy:
Resolution:
Filter:
Temp. Stability:
Sensor:
Pressure connection:
Over-pressure:
Wetted parts:
Units:
0.2, 2, 5, 10, or 20 bar (specified on ordering)
Available on 2 bar range. Measures vacuum to - 1 bar
0.04% of range +/- 1 digit (0.2 bar version, 0.1% of range +/- 1 digit)
4.5 digit (0.2 bar version, 3.5 digit)
Off (4 readings/sec), average of 4 readings, or average of 16 readings
Less than 0.005% per °C
Piezoresistive
1/8” BSP female in a stainless steel manifold
3 x full scale or, 35 bar
Stainless steel & silicon (contaminated media version - stainless steel only)
Bar, PSI, KPa, inWg, cmWg, inHg, mmHg, Kg/cm2, Atm
Loop Current Calibration
Ranges:
Accuracy:
Resolution:
Loop resistance:
Protection:
Sockets:
+/- 200mA, and ‘% of 4-20mA’
0.05% of reading +/- 2 digit, (0.1% for ‘% of 4-20mA’ range)
10 uA (200mA range), 0.1% (% of 4-20mA range)
Less than 2Ω
250 mA automatic reset Poly-Fuse
4mm industry standard
Main Functions
Pressure display in one of 9 user selectable units
Loop current display in mA or % of 4 - 20mA
Leak rate display in pressure units per sec, or per minute, as selected in user set-up Max/Min logging display
RS232 Interface
The 7040’s parameters can be read-back over a RS232 serial link - cable provided. User friendly commands
from the PC allow data to logged directly to the PCs hard disk. Alternatively a calibration software package
such as Time Electronics’ EasyCal can run pre-written calibration procedures and gather the results
automatically. Calibration certificates can be printed on site or back in the lab as required.
General Specification
Power:
Front panel:
Case:
Operating temp:
Storage temp:
Accessories:
Dimensions:
Weight:
Optional Extras:
PP3 battery, life 50 hr continuous use
Polycarbonate membrane keypad
Impact resistant ABS
0 to 50 °C.
-10 to 60 °C
Carry case, Pneumatic fittings kit and hose, Test lead, Serial link cable
6 x 3.5 x 1.2” (157 x 90 x 33 mm)
0.64 lbs (0.29kg)
Hand pressure pump Vac - 40bar
EasyCal calibration software
Calibration Certificates – traceable to NPL and UKAS
Ordering Information
Code
7040
7090
9747
9185
9196
Description
Digital Pressure Calibrator 7040/71xx/CorA
The pressure range is specified as follows:
7100 = 200mbar 7101 = 2 bar 7102 = 5 bar
7103 = 10 bar
7104 = 20 bar
For contaminated media version add /C
For absolute pressure sensor add /A
Pneumatic hand pump – 950mB to 40 bar
EasyCal Software (Automatic Calibration Software, including over 1000 procedures)
Factory Calibration Certificate
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
101
102
7010 Single Channel Pressure Calibrator
Time Electronics
Calibration, Test & Measurement








Range options from 0.2 to 600 bar
Accuracy 0.04% of full scale
Pneumatic or Hydraulic
Over- pressure alarm
Piezo - resistive pressure sensor
Isolated 24/36V loop supply
Loop current measure
Mains / Battery Power
Options:
40 bar pneumatic hand pump
700 bar hydraulic hand pump
7006 Loop-Mate
Rugged portable pressure calibrators designed for applications from 0.2 bar up to 600 bar in eleven ranges specify when ordering. For the 7010, the pressure source is via external hand pumps: The 7090 Pneumatic
(-950 mbar - 40 bar), or 7095 Hydraulic (0 - 700 bar). Also available a dual channel version (see separate
7015 Dual Channel datasheet). Alternatively, when external line pressures are available the 7010 can be
supplied with an internal regulator to control the output pressure - see separate 7016 LPR datasheet.
For process signal calibration the loop signal is displayed on the LCD display to 0.05% accuracy. Loop drive
supply (24V or 36V) is also provided. Both pressure and loop signal can be displayed at the same time to
speed up the calibration of pressure transmitters. Additionally a continuity function is available for testing for
open circuit loops.
The 7010 single channel version allows switch selection of five pressure units. These should be specified on
ordering from the following:- bar, PSI, kPa, MPa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm.
Both pressure and loop current are displayed on 4.5 digit LCD displays.
RS232 connection for display read-back when used with Time Electronics EasyCal calibration software
(option). Straightforward calibration procedures are easy for the user to write within EasyCal. Results from
procedures are stored in EasyCal’s results database and printing calibration certificates on demand is simple.
Power is via internal rechargeable cells with a built in mains charger. This allows the unit to be powered
directly from the mains if required. The 7010 is housed in a strong resin case that provides on-site protection.
All pressure connections are on the side of the case. Leads and an assortment of pressure connection
accessories are provided.
For process control signal simulation Time Electronics’ handheld 7006 Loop-Mate is available as an option. It
provides 4 - 20mA and 0 - 10V signals at levels of 0%, 10%, 25%, 50%, 75%, 90%, 100%. It can also step
through these set points automatically to allow hands free calibration. It is battery powered and can be stored in
the 7010’s pouch. Please see separate datasheet for more information.
www.timeeusa.com
102
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
103
7010 Technical Specifications
Pressure
Range (bar)
Vacuum
0.2
2
5
10
20
35
70
100
200
400
600
Resolution (bar)
.0001
0.01mb
.0001
0.001
0.001
0.001
0.01
0.01
0.01
0.01
0.1
0.1
Acc. % +/-1 digit
0.04
0.1
0.04
0.04
0.04
0.04
0.04
0.04
0.04
0.1
0.1
0.1
Temp Stability:
Less than 70 ppm per °C
Units:
bar, PSI, kPa, MPa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm **
Max Pressure:
2 x range, 1.5 x range for 20 bar and above
Sensor:
Piezo-resistive - stainless steel diaphragm
Over press warning:
1.2 x range full scale - audio and visual (on LCD) warning
Fittings:
Minimess (>20 bar) & Quick Release (<20 bar)
** Specify on ordering: 5 off
Electrical
Range:
Loop current measurement 0 - 200 mA
Resolution:
10 µA
Resistance:
Loop load 5Ω
Accuracy:
0.05% of reading ±1 digit
Loop Drive:
24V or 36V switch selectable, 50 mA max - isolated and with short circuit protection
Continuity:
Threshold: 100Ω with audio and visual warning
RS232:
3.5mm Stereo socket
Terminals:
4 mm industry standard terminal posts
General Specification
Power Source:
Internal rechargeable Nickel Metal Hydride batteries, or mains supply (230V or 110V 50/60 Hz)
Battery Life:
24 hrs of typical usage
Display:
7 segment LCD with 'Low Battery' warning indicator
RS232:
For Read-back (Software not supplied) and re-calibration with supplied software via PC (not supplied)
Case:
Structural resin which is weather-proof to IP 66 standard
Size / Weight:
27 x 25 x 17.5 cm (11” x 10” x 7”), 3 kg (6.5 lbs)
Unit comes supplied with test leads
Ordering Information
Code
Description
7010
Pressure Calibrator single channel (+ pressure ranges required + pressure units required)
7090
Pneumatic hand pump
7095
Hydraulic Pressure Calibration pump
7006
Loop-Mate loop current simulator
9747
EasyCal Software (Automatic Calibration Software, including over 1000 procedures)
9178
Factory Calibration Certificate
9190
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
103
104
7015 Dual Channel Pressure Calibrator
Time Electronics
Calibration, Test & Measurement

Dual Pressure Channel

Range options from 0.2 to 600 bar

Accuracy 0.04% of full scale

Pneumatic or Hydraulic

Over- pressure alarm

Piezo - resistive pressure sensor

Isolated 24/36V loop supply

Loop current measure

Mains / Battery Power
Options:
40 bar pneumatic hand pump
700 bar hydraulic hand pump
7006 Loop-Mate
Rugged portable pressure calibrators designed for applications from 0.2 bar up to 600 bar in eleven ranges specify when ordering. For the 7015, the pressure source is via external hand pumps: The 7090 Pneumatic
(-950 mbar - 40 bar), or 7095 Hydraulic (0 - 700 bar). Also available a single channel version (see separate
7010 Single Channel datasheet). Alternatively, when external line pressures are available the 7015 can be
supplied with an internal regulator to control the output pressure - see separate 7016 LPR datasheet.
For process signal calibration the loop signal is displayed on the LCD display to 0.05% accuracy. Loop drive
supply (24V or 36V) is also provided. Both pressure and loop signal can be displayed at the same time to
speed up the calibration of pressure transmitters. Additionally a continuity function is available for testing for
open circuit loops.
The 7015 dual channel version allows switch selection of five pressure units on channel one and four pressure
units on channel two. These should be specified on ordering from the following:- bar, PSI, kPa, MPa, inWg,
cmWg, inHg, mmHg, Kg/cm2, atm. Both pressure and loop current are displayed on 4.5 digit LCD displays.
RS232 connection for display read-back when used with Time Electronics EasyCal calibration software
(option). Straightforward calibration procedures are easy for the user to write within EasyCal. Results from
procedures are stored in EasyCal’s results database and printing calibration certificates on demand is simple.
Power is via internal rechargeable cells with a built in mains charger. This allows the unit to be powered
directly from the mains if required. The 7015 is housed in a strong resin case that provides on-site protection.
All pressure connections are on the side of the case. Leads and an assortment of pressure connection
accessories are provided.
For process control signal simulation Time Electronics’ handheld 7006 Loop-Mate is available as an option. It
provides 4 - 20mA and 0 - 10V signals at levels of 0%, 10%, 25%, 50%, 75%, 90%, 100%. It can also step
through these set points automatically to allow hands free calibration. It is battery powered and can be stored in
the 7015’s pouch. Please see separate datasheet for more information.
www.timeeusa.com
104
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
105
7015 Technical Specifications
Pressure
Range (bar)
Vacuum
0.2
2
5
10
20
35
70
100
200
400
600
Resolution (bar)
.0001
0.01mb
.0001
0.001
0.001
0.001
0.01
0.01
0.01
0.01
0.1
0.1
Acc. % +/-1 digit
0.04
0.1
0.04
0.04
0.04
0.04
0.04
0.04
0.04
0.1
0.1
0.1
Temp Stability:
Less than 70 ppm per °C
Units:
bar, PSI, kPa, MPa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm **
Max Pressure:
2 x range, 1.5 x range for 20 bar and above
Sensor:
Piezo-resistive - stainless steel diaphragm
Over press warning:
1.2 x range full scale - audio and visual (on LCD) warning
Fittings:
Minimess (>20 bar) & Quick Release (<20 bar)
** Specify on ordering: 5 off
Electrical
Range:
Loop current measurement 0 - 200 mA
Resolution:
10 µA
Resistance:
Loop load 5Ω
Accuracy:
0.05% of reading ±1 digit
Loop Drive:
24V or 36V switch selectable, 50 mA max - isolated and with short circuit protection
Continuity:
Threshold: 100Ω with audio and visual warning
RS232:
3.5mm Stereo socket
Terminals:
4 mm industry standard terminal posts
General Specification
Power Source:
Internal rechargeable Nickel Metal Hydride batteries, or mains supply (230V or 110V 50/60 Hz)
Battery Life:
24 hrs of typical usage
Display:
7 segment LCD with 'Low Battery' warning indicator
RS232:
For Read-back (Software not supplied) and re-calibration with supplied software via PC (not supplied)
Case:
Structural resin which is weather-proof to IP 66 standard
Size / Weight:
27 x 25 x 17.5 cm (11” x 10” x 7”), 3 kg (6.5 lbs)
Unit comes supplied with test leads
Ordering Information
Code
Description
7015
Pressure Calibrator dual channel (+ pressure ranges required + pressure units required)
7090
Pneumatic hand pump – 950mB to 40 bar
7095
Hydraulic Pressure Calibration pump – 700 bar
7006
Loop-Mate loop current simulator
9747
EasyCal Software (Automatic Calibration Software, including over 1000 procedures)
9178
Factory Calibration Certificate
9190
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
105
106
7016 LPR Pressure Calibrator
Time Electronics
Calibration, Test & Measurement









Regulated Low Pressure
Range options from 0.2 to 20 bar
Accuracy 0.04% of full scale
Pneumatic
Over- pressure alarm
Piezo - resistive pressure sensor
Isolated 24/36V loop supply
Loop current measure
Mains / Battery Power
Options:
40 bar pneumatic hand pump
7006 Loop-Mate
Rugged portable pressure calibrators designed for applications from 0.2 bar up to 20 bar in nine ranges specify when ordering. For pressures above 20 bar please contact us for options. The external line pressure
can be sourced from a compressor or cylinder (see table for maximum pressures). The 7016 can be used with
the 7090 pneumatic hand pump (-950 mbar to 40 bar). Alternatively, the 7016 can be supplied without the
internal regulator for hydraulic or pneumatic use up to 600bar - see separate 7010 Single channel and 7015
Dual channel datasheets.
For process signal calibration the loop signal is displayed on the LCD display to 0.05% accuracy. Loop drive
supply (24V or 36V) is also provided. Both pressure and loop signal can be displayed at the same time to
speed up the calibration of pressure transmitters. Additionally a continuity function is available for testing for
open circuit loops.
The 7016 allows switch selection of five pressure units. These should be specified on ordering from the
following:- bar, PSI, kPa, MPa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm.
Both pressure and loop current are displayed on 4.5 digit LCD displays.
RS232 connection for display read-back when used with Time Electronics EasyCal calibration software
(option). Straightforward calibration procedures are easy for the user to write within EasyCal. Results from
procedures are stored in EasyCal’s results database and printing calibration certificates on demand is simple.
Power is via internal rechargeable cells with a built in mains charger. This allows the unit to be powered directly
from the mains if required. The 7015 is housed in a strong resin case that provides on-site protection. All
pressure connections are on the side of the case. Leads and an assortment of pressure connection
accessories are provided.
For process control signal simulation Time Electronics’ handheld 7006 Loop-Mate is available as an option. It
provides 4 - 20mA and 0 - 10V signals at levels of 0%,10%,25%,50%,75%,90%,100%. It can also step through
these set points automatically to allow hands free calibration. It is battery powered and can be stored in the
7016’s pouch. See separate datasheet.
www.timeeusa.com
106
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
107
7016 Technical Specifications
Pressure
Range (bar)
Vacuum
0.2
2
5
10
20
.0001
0.01mb
.0001
0.001
0.001
0.001
Regulator
Yes
Yes
Yes
Yes
Yes
Yes
Accuracy % +/-1 digit
0.04
0.1
0.04
0.04
0.04
0.04
Resolution (bar)
Temp Stability
Less than 70 ppm per °C
Units
bar, PSI, kPa, MPa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm **
Max Pressure
2 x range, 1.5 x range for 20 bar and above
Sensor
Piezo-resistive - stainless steel diaphragm
Over press warning
1.2 x range full scale - audio and visual (on LCD) warning
Fittings
Quick Release
** Specify on ordering: 5 off for channel one.
Electrical
Range
Loop current measurement 0 - 200 mA
Resolution
10 µA
Resistance
Loop load 5Ω
Accuracy
0.05% of reading ±1 digit
Loop Drive
24V or 36V switch selectable, 50 mA max - isolated and with short circuit protection
Continuity
Threshold: 100Ω with audio and visual warning
RS232
3.5mm Stereo socket
Terminals
4 mm industry standard terminal posts.
General Specification
Power Source:
Internal rechargeable Nickel Metal Hydride batteries, or mains supply (230V or 110V 50/60 Hz)
Battery Life:
24 hrs of typical usage
Display:
7 segment LCD with 'Low Battery' warning indicator
RS232:
For Read-back (Software not supplied) and re-calibration with supplied software via PC (not supplied)
Case:
Structural resin which is weather-proof to IP 66 standard
Size / Weight:
27 x 25 x 17.5 cm (11” x 10” x 7”), 3 kg (6.5 lbs)
Unit comes supplied with test leads
Ordering Information
Code
Description
7016
Pressure Calibrator – Low Pressure Regulated (+ pressure ranges required + pressure units required)
7090A
Pneumatic hand pump – 950mB to 40 bar
7006
Loop-Mate loop current simulator
9747
EasyCal Software (Automatic Calibration Software, including over 1000 procedures)
9178
Factory Calibration Certificate
9190
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
107
108
7018 Differential Pressure Calibrator
Time Electronics
Calibration, Test & Measurement

Differential range options from 0.2 to 10 bar

Best accuracy 0.04% of full scale

Pneumatic

Over- pressure alarm

Piezo - resistive pressure sensor

Isolated 24/36V loop supply

Loop current measure

Mains / Battery Power
Options:
40 bar pneumatic hand pump
700 bar hydraulic hand pump
7006 Loop-Mate
From our range of rugged portable pressure calibrators designed for applications from 0.2 bar up to 600 bar,
the 7018 differential calibrator covers DP from 0.2 bar to 10 bar in four ranges - specify when ordering the DP
and static line pressures, The optional 7090 Pneumatic hand pump can be used as a pressure source
covering the range -950 mbar to 40 bar, see separate datasheet.
Also available is a single channel pressure calibrator the 7010, complemented by a dual channel version; the
7015, see separate data sheets. Alternatively, when external line pressures are available the 7010 can be
supplied with an internal regulator to control the output pressure - see separate 7016 LPR datasheet.
For process signal calibration the loop signal is displayed on the LCD display to 0.05% accuracy. Loop drive
supply (24V or 36V) is also provided. Both pressure and loop signal can be displayed at the same time to
speed up the calibration of pressure transmitters. Additionally a continuity function is available for testing for
open circuit loops.
The 7018 allows switch selection of four pressure units. These should be specified on ordering from the
following:- bar, PSI, kPa, cmWg, inHg, mmHg, Kg/cm2.
Both pressure and loop current are displayed on a 4.5 digit LCD switchable back lit display.
RS232 connection for display read-back when used with Time Electronics EasyCal calibration software
(option). Straightforward calibration procedures are easy for the user to write within EasyCal. Results from
procedures are stored in EasyCal’s results database and printing calibration certificates on demand is simple.
Power is via internal rechargeable cells with a built in mains charger. This allows the unit to be powered
directly from the mains if required. The 7018 is housed in a strong resin case that provides on-site protection.
All pressure connections are inside the case mounted on the top panel. Leads and an assortment of pressure
connection accessories are provided.
For process control signal simulation Time Electronics’ handheld 7006 Loop-Mate is available as an option. It
provides 4 - 20mA and 0 - 10V signals at levels of 0%, 10%, 25%, 50%, 75%, 90%, 100%. It can also step
through these set points automatically to allow hands free calibration. It is battery powered and can be stored in
the 7018’s pouch. Please see separate datasheet for more information.
www.timeeusa.com
108
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
109
7018 Technical Specifications
Pressure
Range (bar)
Vacuum
0.2
2
5
10
Resolution (bar)
.0001
0.01mb
.0001
0.001
0.001
Acc. % +/-1 digit
0.04
0.1
0.04
0.04
0.04
Temp Stability:
Less than 70 ppm per °C
Units:
bar, PSI, kPa, cmWg, inHg, mmHg, Kg/cm2, **
Max Pressure:
2 x range, 1.5 x range for 20 bar and above
Max Static
Pressure:
20bar
Sensor:
Piezo-resistive - stainless steel diaphragm
Over press
warning:
1.2 x range full scale - audio and visual (on LCD) warning
Fittings:
Minimess (>20 bar) & Quick Release (<20 bar)
** Specify on ordering: 4 off
Electrical
Range:
Loop current measurement 0 - 200 mA
Resolution:
10 µA
Resistance:
Loop load 5 Ω
Accuracy:
0.05% of reading ±1 digit
Loop Drive:
24V or 36V switch selectable, 50 mA max - isolated and with short circuit protection
Continuity:
Threshold: 100Ω with audio and visual warning
RS232:
3.5mm Stereo socket
Terminals:
4 mm industry standard terminal posts
General Specification
Power Source:
Internal rechargeable Nickel Metal Hydride batteries, or mains supply (230V or 110V 50/60 Hz)
Battery Life:
24 hrs of typical usage
Display:
7 segment LCD with 'Low Battery' warning indicator
RS232:
For Read-back (Software not supplied) and re-calibration with supplied software via PC (not supplied)
Case:
Structural resin which is weather-proof to IP 66 standard
Size / Weight:
27 x 25 x 17.5 cm (11” x 10” x 7”), approx 3 kg (6.5 lbs)
Unit comes supplied with test leads
Ordering Information
Code
Description
7018
Pressure Calibrator differential (+ differential + static pressures + pressure units required)
7090
Pneumatic hand pump –950mB to40 bar
7095
Hydraulic Pressure Calibration pump 0 to 700bar
7006
Loop-Mate loop current simulator
9747
EasyCal Software (Automatic Calibration Software, including over 1000 procedures)
9178
Factory Calibration Certificate
9190
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeelectronics.com
Tel: +44 (0)1732 355993
PROCESS CONTROL EQUIPMENT
Email: [email protected]
109
110
7090 Pneumatic Calibration Pump
Time Electronics
Calibration, Test & Measurement
 Pressure to 40bar (600psi)
 Vacuum to -950 mbar
 Oversized check valve for smooth controlled operation
 Non-oil based lubricant used on all moving parts
 Hoses, Fittings, and Carry Case Included
 Optional Digital Gauge
The 7090 is a pressure and vacuum calibration pump that combines performance with rugged design. Its
features include contoured cushioned handles for comfort and control, protective caging for the vent valve
guarding against accidental damage, and dual o-rings on all pistons to ensure zero leakage.
Specifications
Range:
Vacuum - 950 mbar to pressure 40bar (600psi)
Compatibility:
All gauges and calibrators
Connections:
(2 ports) 1/4 inch and 1/8 inch NPT/BSP
Hoses:
1 meter 6/4mm hose
Weight:
2lbs (910g)
Size:
W 5” (handle to handle) x H 8” (125 x 200mm)
Options:
7089 Digital Gauge
Ordering Information
Code
Description
7090
Pneumatic Calibration Pump – Vacuum 950 mbar (28"Hg) to pressure 40bar (600psi)
7089
Digital pressure gauge for 7090
www.timeeusa.com
110
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
111
7095 Hydraulic Calibration Pump
Time Electronics
Calibration, Test & Measurement
 0 – 700bar (10,000psi)
 Priming feature
 Triple filtration (prevents failure caused by dirt)
 Non-oil based lubricant used on all moving parts
 Built in pressure relief valve (prevents over pressurizing)
 Hoses, Fittings, and Carry Case Included
 Optional Digital Gauge
The 7095 is a hydraulic calibration pump that combines performance with rugged design. Its features include
contoured cushioned handles for comfort and control, protective housing for the vent knob, a shatter proof
reservoir, and oversized check valves for smooth controlled operation
Specifications
Range:
0 – 700bar (10,000psi)
Compatibility:
Most hydraulic fluids, oils and water
Connections:
(2 ports) 1/4 inch and 3/8 inch NPT/BSP
Hoses:
Minimess 630bar
Weight:
3lbs (1.4kg)
Size:
W 5“ (handle to handle) x H 9” (125 x 240mm)
Options:
7096 Digital Gauge
Ordering Information
Code
Description
7095
Hydraulic Calibration Pump – 0 to 700bar (10,000psi)
7096
Digital Pressure Gauge
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
111
112
1048 Current - Voltage - Loop Calibrator
Time Electronics
Calibration, Test & Measurement

Source & Measure - Current & Voltage

3 Source ranges 0 - 22mA & 0 - 22V

3 Measure ranges 0 - 70mA & 0 - 50V

Transmitter Simulator/Sink

Output Steps and Ramps

Fine adjustment (Inching)

Accuracy 0.02% of span
The 1048 is a current, voltage, and process loop calibrator that covers the needs of an R&D
lab and process control engineer. Source and measure in three current and voltage ranges
plus a transmitter simulator/sink function. It has 4.5 digit (0.005% of span) resolution.
Output functions include step, ramp and inching. There are no key press menus to learn, just
switches and buttons. A multi-turn potentiometer controls the output with up/down
incrementing buttons for fine control. The output can be reversed (+/-) and zeroed at the flick
of a switch. The front panel features a large easy-to-read 4.5 Digit LCD display which autoranges. Manual reset of the ramp function is also provided for quick restore.
1048 Applications
2 w ire transducer/transmitter
Receiving instrument
Sensor
+
-
+
-
Read Mode
Source Mode
Controller
+
Pow er Supply
2 w ire transducer/transmitter
+
Sensor
+
-
Pow er
Supply
Read & Power Mode
Sink Mode (transmitter simulator)
www.timeeusa.com
112
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
113
1048 Technical Specifications
DC CURRENT - Source and Measure
Span:
0 - 22mA, over-range to 70mA for
measure only
Accuracy:
0.02% of span
Resolution:
1uA (0-19.999mA), 10uA (above 20mA)
DC VOLTS - Source and Measure
Span:
0 - 22V, over-range to 50V for measure
only
Accuracy:
0.02% of span
Resolution:
1mV (0-19.999V), 10mV (above 20V)
Span:
Accuracy:
Resolution:
0 - 2.2mA
0.02% of span
0.1uA (0-1.9999mA),1uA (above2mA)
Span:
Accuracy:
Resolution:
0 - 2.2V
0.02% of span
100uV (0-1.9999V), 1mV (above 2V)
Span:
Accuracy:
Resolution:
0 - 220uA
0.05% of span
10nA (0-199.99uA), 0.1uA (above 200uA)
Span:
Accuracy:
Resolution:
0 - 220mV
0.05% of span
10uV(0-199.99mV), 0.1mV (above 200mV)
Output res:
Measure load:
Approx <2 ohms. Max current 50mA
1Mohm on all ranges
Max source load: 1.1Kohms @ 20mA. Max drive: 22V
Measure load:
1K,110,16 ohm for 0.22, 2.2, 22mA
SINK (TX SIM)
2 wire transmitter simulation: External excitation voltage, 3V min, 50V max. The current sink levels are adjustable, with
accuracies as in the 3 source ranges shown above.
Note: Accuracies in all measure modes are +/-1 digit
OUTPUT STEPS
5 fixed 4mA steps for current output 4, 8, 12, 16 & 20 mA
11 fixed 1V steps for voltage output 0,1,2...10V
21 fixed steps 1V/1mA for V & I output 0,1,2…...20
Stepping can be done manually or automatically (Autostep) Stepping speed is adjustable (1-9 sec/step). Dwell time (top
and bottom) is one step period. In step mode the accuracy is limited to 0.05% of span +/-1digit.
OUTPUT RAMP
Current Ramp 4 to 20, or 0 to 20 on all ranges.
Voltage Ramp 0 to 10, or 0 to 20 on all ranges.
Ramp time 7sec. Dwell (top/bottom) 5sec. Manual restart.
Ramp operation is also available in Sink (TX SIM).
OUTPUT ADJUSTMENT
A ten turn potentiometer is provided for quick positioning with fine adjust using up/down incrementing buttons.
Power: A single internal 9V PP3 size battery or an optional external mains power supply. Battery life: Typically about
15hrs use. Continuous operation in current source mode will shorten the battery life. A 15 min inactivity auto-power down
feature is also included to conserve the battery.
Operating temperature: -10 to 50 °C (14 to 120 °F)
Storage temperature: -30 to 70 °C (-22 to 160 °F)
Operating humidity: 10-90% non-condensing at 25 °C
General Specification
Dimensions:
5.6 x 2.9 x 2.0” (142 x 78 x 50mm)
Weight:
0.6lbs (0.28kg)
Housing:
A pocket sized hard ABS case in a leatherette carry case. Leads can be stored inside of the case.
Optional Extras: External Power Unit: 230 or 110V mains power supply
Calibration Certificates
Ordering Information
Code
Description
1048
V - I - Loop Calibrator 0.02%
7643
230/240V AC 50/60Hz Mains Power Supply
7652
110V Mains Power Supply
9176
Factory Calibration Certificate
9138
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
113
114
1077 Milliamp Transducer/Simulator
Time Electronics
Calibration, Test & Measurement

3 Operating modes

100mA Source & Load

24V Line mode

0.02% Accuracy

Safety terminals

Removable protective boot

Battery level indicator
The 1077 is a hand held instrument designed for the testing and simulation of milliamp
transducer system. Its rugged and compact construction makes it ideal for use in the field or
laboratory.
Three operating modes are possible 1) As an adjustable current load (simulating the transducer) on the line, the 1077 will draw
up to 100mA from the line. The required current is set by the front panel controls.
2) As an adjustable power supply (14V to 40V) with accurate measurement and display of
the current drawn from the circuit.
3) As a precision current source with 14V to 40V max. (adjustable) drive capacity. The
1077 will source the set current up to 100mA to the loop.
Safety Terminals: Fully compatible with 4mm shrouded plugs, as well as standard plugs,
bare wires, and spade terminals.
Added Protection: The 1077 comes fitted with an ergonomic rubber boot (9028) providing
increased protection and durability. The boot has a textured grip for comfortable handling
and openings at the top and bottom to allow access to the battery meter and a position to
place labels if required. The boot is easy to remove if the user prefers a stand-alone unit or
to house the 1077 in the 9027 carry case.
The versatile capabilities make the 1077 ideal for process control engineers. It is supplied
with rechargeable batteries, mains charger, and protective boot as standard.
www.timeeusa.com
114
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
115
1077 Technical Specifications
CURRENT LOAD (TRANSDUCER SIMULATION)
Output:
0 to 100mA in 3 ranges:
0 – 99.99mA in 10µA steps
0 – 9.999mA in 1µA steps
0 – 999.9µA in 0.1µA steps
Accuracy:
± 0.02% of setting; ± 0.02% of range; ±0.02µA
Output Stability:
Better than 60 ppm per ºC. Better than 25 ppm per hour at constant temp.
Input Voltage:
30V maximum, 3V minimum
Voltage Limit Warning:
A front panel indicator provides indication of insufficient terminal voltage.
24 VOLT LINE SIMULATION
24 V Line Simulation:
Adjustable 14V to 40V, 100mA current limit, Maximum output power 2.4 W.
Display:
A 3.5 digit (1999 max) LCD display indicating line current.
Measure Range:
0 – 20mA
Resolution:
10µA
Accuracy:
0.2% of reading + 1 count
CURRENT SOURCE
Output:
0 to 100mA in 3 ranges –
0 – 99.99mA in 10µA steps
0 – 9.999mA in 1µA steps
0 – 999.9µA in 0.1µA steps
Accuracy:
± 0.05% of setting, ± 0.02% of range
Output Stability:
Better than 60 ppm per ºC. Better than 25 ppm per hour at constant temp.
Output Noise:
Less than 15 ppm of full scale
Voltage Capability:
Adjustable 14V – 40V
Output Power:
2.4 watts maximum
Output Limit Warning:
A front panel indicator provides indication of insufficient drive voltage.
Power Supply:
NiCad rechargeable batteries with external mains recharger. Recharge time
approximately 10 hours. Operating time typically 10 hours.
General Specification
Dimensions:
4.5 x 4 x 8” (110 x 75 x 200 mm)
Weight:
2.4 lb (1.1 kg)
Supplied with:
Protective boot, NiCad cells and mains charger.
Optional Extras:
Carry Case
Calibration Certificates
Ordering Information
Code
Description
1077
Transim (Milliamp Transducer/Line Simulator)
9027
Leatherette Carry Case
9158
Factory Calibration Certificate
9108
UKAS/NIST Calibration Certificate
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
115
116
7005 Loop Calibrator
Time Electronics
Calibration, Test & Measurement
 Loop Source - Current or Voltage
 Loop Measure - Current or Voltage
 Loop Current Sink
 Accuracy 0.01%
 Resolution 1uA or 1mV
 Programmable Ranges
 Manual Step, Auto-Step and Ramp
 Square Root Functions for Flow
 20mA drive capability into 1100 ohms
The 7005 is a micro-processor based instrument for the calibration and simulation of voltage
and current loops. It can operate in three modes:
a) Loop current/voltage Source (simulating a transmitter and the loop supply)
b) Sink of loop current (simulating a transmitter)
c) Measurement of loop current/voltage (simulating a loop indicator).
Manual step of the output is available at five calibration points, 0%, 25%, 50%, 75% and
100% of span. Automatic stepping of the output is also available both up and down with
programmable dwell times.
Continuous up/down ramping is also available with user programmable ramp rates and dwell
time (top and bottom).
In source mode the range can be user programmed to any value between 0mA and 50mA,
or 0V and 21V. For example a low point of 10mA and a high point of 50mA could be set
giving a span of 40mA
Measure mode provides both voltage and current measuring capability with 5 digit resolution.
Ranges are 0 to ±5V and ±5 to ±25V, 0 to ±25mA and ±25 to ±125mA. Alternatively the
signal can be measured as a % of span for the following ranges, 4 to 20mA, 0 to 20mA,
square root 4 to 20mA, square root 0 to 20mA. For all measurements a Min/Max recording
function is available on demand.
An internal NiCad battery can power the unit for typically 9 hours and an external mains
charger is supplied as standard. An automatic power-down feature is incorporated to
conserve battery life.
www.timeeusa.com
116
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
117
7005 Technical Specifications
Measurement
Source
DC CURRENT 0 to ±125mA, Auto-ranging
Accuracy (0 to 25mA):
±0.01% of reading ±2uA
Resolution:
1uA
Accuracy (25 to 125mA): ±0.01% of reading ±20uA
Resolution:
10uA
Measure load:
24.5Ω on all ranges
DC VOLTS
0 to ±25V, Auto-ranging
Accuracy (0 to 5V):
±0.01% of reading ±0.4mV
Resolution:
0.1mV
Accuracy (5 to 25V):
±0.01% of reading ±2mV
Resolution:
1mV
Measure load:
10MΩ on all ranges
DC CURRENT 0 to 50mA
Accuracy:
±0.01% of setting ±2uA
Resolution:
1uA
Max drive:
22V
Loop Resistance:
1100Ω @ 20mA max
DC VOLTS 0 to 21V @ 50mA
Accuracy:
±0.01% of setting ±4mV
Resolution:
1mV
Output resistance:
< 1Ω
DC CURRENT SINK 0 to 50mA
Accuracy:
±0.01% of setting ±2uA
Resolution:
1uA
Min external drive:
4V
Max external drive:
40V
Summary of Functions
SOURCE MODE
 User programmable ranges - any values between 0 and 50mA or 0 and 21V.
 Fixed ranges are available: 4 to 20mA, 0 to 20mA, sqrt 4 to 20mA, sqrt 0 to 20mA.
 Fine adjustment (inching) is available for precise deviation from the calibration point.
 Manual step output - five calibration points 0%,25%,50%,75% and 100%
 Automatic step output (up/down) - five cal points with programmable dwell period.
 Ramp output - programmable ramp rate (0 to 20mA/Sec or 0 to 20V/Sec)
programmable dwell period (0 to 1000 seconds)
MEASURE MODE
This mode provides both voltage and current measuring capability with 5 digit resolution. Ranges are 0 to ±5V
and ±5 to ±25V, 0 to ±25mA and ±25 to ±125mA. Alternatively the signal can be measured as a % of span
for the following ranges, 4 to 20mA, 0 to 20mA, square root 4 to 20mA, square root 0 to 20mA. For all
measurements a Min/Max recording function is available on demand.
General Specification
Power:
Internal NiCad battery. Battery life typically >9 hours. Auto power-down.
External battery charger supplied
Dimensions:
6.7 x 3.5 x 2” (17 x 9 x 5 cm)
Weight:
0.8 lbs (0.42kg)
Housing:
Case Impact resistant ABS
Optional Extras:
Calibration Certificates
Unit comes supplied complete with lead set.
Ordering Information
Code
Description
7005
Loop Calibrator
9184
Factory Calibration Certificate
9195
NIST/UKAS Calibration Certificate (ISO 17025)
www.timeeusa.com
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
117
118
7006/7007 Loop-Mates 1 and 2
Time Electronics
Calibration, Test & Measurement








Pocket sized 140 x 66 x 27 mm
4 - 20mA or 0 - 10V loops
7 calibration set-points
TxSim and RxTest (Loop-Mate1)
RxSim and TxTest (Loop-Mate2)
Auto-Step output - adjustable rate
Battery powered PP3
Internal loop drive supply
The Loop-Mates are single function low-cost pocket sized units, designed for test and calibration of process
loops. Simplicity of operation is their key - no keypads or complicated selections. Engineers will be able to pick
them up and get to work immediately. Just select 4 - 20mA, or 10V loop, and TxSim, RxTest, RxSim or TxTest.
Both have internal loop drive supplies, which can be used to power the loop if required.
Loop-Mate1 is the simulator and acts as a source to provide the loop signals, 4 - 20mA or 0 - 10V.
No complicated selection of the output, just operate up/down buttons to increase or decrease the signal. There
are 7 set-points, 0%, 10%, 25%, 50%, 75%, 90%, 100%. Each is indicated on a high brightness LED and an
audible beep sounds as you step between them. Auto-stepping mode (adjustable rate) allows Loop-Mate1 to
be left connected stepping up and down. The engineer can then move to another location to check (using LoopMate2) that the signal is arriving correctly and is within specification.
Loop-Mate2 is a dedicated loop signal indicator, just as easy to operate. Once again select the loop type, 4 20mA, or 0 - 10V, and whether you want the display in direct units, or % of span. The LCD display shows the
signal to an accuracy of 0.05% either in mA, V, or % of span.
Both units are powered by a single standard PP3 battery that gives up to 40hrs continuous use.
7006 & 7007 Technical Specifications
7006 Loop-Mate1
7007 Loop-Mate2
Range:
4 - 20mA, or 0 - 10V
Range:
4 - 20mA, 0 - 10V, 0 - 50V
Set-Points:
0, 10, 25, 50, 75, 90, 100% of span
Display:
LCD 4 digits, mA, V, or % of span
Accuracy:
0.1%
Accuracy:
0.05%
Modes:
TxSim, or RxTest
Modes:
RxSim, TxTest, or 50mA/50V measure
Loop Supply:
Internal, 25mA max
Loop supply:
Internal, 25mA max
Auto-Step:
Up/Down/Up, 0.5, 1, 2, 4, or 8sec/step
General Specification (Applies to both units unless stated)
Power:
PP3 battery, typical life 40hrs
Dimensions:
L 5.5 x W 6.6 x D 1.2” (L 140 x W 65 x D 30mm)
Weight:
7006: 0.4 lbs (180g)
7007: 0.44 lbs (200g)
Optional Extras:
Calibration Certificates
Loop-Mates are supplied with a carrying case, leads and technical manual.
Ordering Information
Code
Description
7006
Loop-Mate 1
7007
Loop-Mate 2
9145
Factory Calibration Certificate (7006 and 7007)
9144
UKAS/NIST Traceable Calibration Certificate (7006 and 7007)
www.timeeusa.com
118
Tel: 516-723-9909
PROCESS CONTROL EQUIPMENT
Email: [email protected]
119
Calibration Benches
The Time Electronics Calibration Bench is designed for a wide range of calibration
and test procedures. It covers temperature, pressure, and electrical signals;
calibrating multi-meters, AC/DC signal sources, frequency timers, oscilloscopes,
resistance boxes, thermocouple transmitters, pressure transducers, loop signal
indicators, and much more.
TE CalBench .................................................................................................................................... 120
Introduction........................................................................................................................................ 121
7080 Bench, Primary Console and 7081 Secondary Console .......................................................... 122
Power Modules.................................................................................................................................. 123
Bench Control Centre and EasyCal Software ................................................................................... 125
Pressure Modules ............................................................................................................................. 126
Loop and Temperature Modules ....................................................................................................... 134
Custom Design Modules ................................................................................................................... 138
External Options ................................................................................................................................ 139
Bench Extras ..................................................................................................................................... 140
Laboratory Design ............................................................................................................................. 141
Reference Tables .............................................................................................................................. 143
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
119
120
Calibration Bench
The ultimate multifunction calibration station from Time Electronics
TEMPERATURE – PRESSURE – ELECTRICAL SIGNALS

Multimeters

Clamp meters

AC/DC signal sources

RTD transmitters

Signal generators

Temperature sensors

Frequency meters

Power supplies

Timer counters

Loop signal indicators

Oscilloscopes

Thermocouple transmitters

AC/DC Milli-voltmeters

Pressure transducers

Ohm meters

Pressure transmitters

Resistance boxes

Pressure switches, gauges

Temperature indicators

Loop signal transmitters
www.timeeusa.com
120
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
121
Introduction
CalBench is the ultimate multifunction calibration station from Time Electronics. A wide range of standard
modules can be mounted in the primary console; this gives a highly flexible system that is both functional and
easy to use. Further expansion can be achieved by adding the optional secondary console 7081.
Core modules cover electronic signal, temperature, and pressure
applications, non-standard modules for special applications can be
incorporated into the bench consoles; each module is an independent
item and there is a high degree of inter-changeability. This allows
each bench to be custom designed to meet specific engineering
requirements.
Functions are clearly defined on each module and a competent
technician will quickly master the operation of the system without
expensive training or constant reference to manuals.
Module Options
Pressure: Ranges from vacuum to 600bar. Also available is an Automatic Pressure Calibrator that allows 4
preset points to be selected at the push of a button, or by EasyCal remote control.
Power: Variable AC mains, variable DC and fixed quad or dual DC supplies can be fitted.
Loop and Temperature: High accuracy loop calibrator modules with source, measure and sink functions.
Temperature calibrators capable of measuring and simulating RTDs/thermocouples.
External Options: Pneumatic and hydraulic handheld calibration pumps, dry block calibrators, solder stations,
vices, laboratory furniture, and more.
Multifunction Calibrator and Control Centre
Mounted centrally in the console with touch
screen control. Source and measure voltage,
current, resistance, frequency and much more.
To make calibration faster and more
productive, the control centre is preloaded with
Time Electronics’ well-established EasyCal
software, which integrates with bench modules.
Offering over 1000 test procedures and
networking capabilities, it fully automates the
calibration process. Engineers can print and
customise test certificates as required.
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
121
122
7080 Bench, Primary Console and 7081 Secondary Console
The Calibration Bench is constructed from a 7080 bench and primary console. The Secondary Console, 7081 is
an optional expansion.
The bench consists of frame, back plates, support arms, and worktop. It is supplied in knockdown format that is
simple to assemble - a separate assembly instruction manual is provided.
The primary console is mounted above the tabletop workspace and houses the calibration modules, DC and AC
power supplies and the central control centre. Switchable under-console lighting is provided as a standard
feature.
The Secondary console is located under the primary console, and can house power supplies, pressure
calibration modules, and temperature distribution.
These consoles are supplied complete, fully tested and with the modules installed. They are ready to operate
and require only mains power and line pressure to be connected.
The bench assembly is constructed from mild steel throughout. The side panels and console support arms are
welded to provide a strong frame. The whole assembly paint finished in hardwearing light grey oven baked paint.
Primary
Console
Bench with back plate
and drawer option
Secondary
Console
Dimensions
Overall (including console):
Width 200 x height 156 (or 166) x depth 85cm, 175Kg typical.
Primary Console:
Width 200 x height 29 x depth 47cm, 90Kg typical.
Secondary Console:
Width 192 x height 40 x depth 19.5 cm, 30Kg typical.
Height from worktop
Primary Console:
42cm
Secondary Console:
12.5cm
Worktop:
Width 200 x 80 deep x 3.8cm, 85cm above floor, durable finish.
Supply Connections
Electrical – The Primary console is powered from a single-phase mains supply via a 16A heavy-duty type IEC socket at
the rear of the console.
The Secondary console is powered from the primary console via a IEC power link cable.
Pressure - 'The external line pressure input ports are arranged on the rear of the primary and secondary consoles
www.timeeusa.com
122
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
123
Power Modules
7082 Mains Power Controller
Mains Power is controlled via a 7082 single-phase unit
equipped with 2 mains power sockets (types
selectable). A further 4 sockets are available on the
underside of the console. A mains power switch,
residual current circuit breaker with over-current
protection (RCBO), and under console lighting switch
are included. Mains input and lighting supply lines are
filtered.
The mains voltage is continuously monitored on a
digital meter. The two front panel sockets can be
supplied via an isolation transformer as an optional
extra. With this fitted the total current from the two
sockets is limited to 1A. Another additional option is a
110V DC 5A supply with circuit breaker.
Available fittings include UK 13A, Euro Shuko 16A, Indian Round Pin 15A, and US 15A
Panel size: Width 270 x height 201mm
Specification
Switches:
Mains power on/off switch to provide isolation for the entire bench
Lighting switch to provide separate control of the work-top lighting
Protection:
16A overload protection for entire bench. Residual current protection is 0.03A.
5amp circuit breaker is fitted for the unregulated 110 volt DC supply option.
Sockets:
2 x console front panel earthed sockets, 4 x console underside earthed sockets.
2 x 4mm front panel shrouded sockets for the 110-volt DC supply option.
Meters:
Mains voltage (0-300V)
Filter:
2 filters fitted to attenuate mains spikes.
Panel size:
Width 270 x height 198mm.
Cooling:
2 x Mains powered 80mm cooling fans are fitted internally to the console.
Earthing:
A PE socket is provided. All metal parts of the bench are connected to mains earth.
Options
7063
Isolated mains power up to 1 Amp, from the two front sockets. A 1 Amp cartridge fuse protects the supply.
7075
110 volts DC up to 5 Amps. The supply is via two front panel mounted shrouded sockets and is protected by
a reset-able 5 Amp circuit breaker, this also acts as a independent 110V power switch.
7083 Dual 24V DC Supply
The 7083 provides two 24V, 2A outputs, which are floating with respect to
each other and ground. A power on/off switch, fuses and LED indicators are
provided. It is suitable for powering loop signal instrumentation.
Output: 2 x 24v, 2A
Panel size: Width 131 x height 201mm
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
123
124
Power Modules
7088 Variable 0 to 270V 50Hz 10A Power Unit
(0 to 150v 60Hz 10A also available)
The 7088 provides variable 50Hz AC power up to
10Amps. The output voltage and current are monitored
on two meters and is available from a front panel socket
(type selectable when placing order). The output is
protected by a 10A circuit breaker. Further protection is
provided a front panel fuse. The output voltage is
adjustable by turning the front panel control knob. An
independent incoming power switch is also provided.
Please note this power supply is not isolated from the
mains supply and the highest voltage is dependant
upon the mains line voltage
Panel size: Width 350 x height 201mm
7086 Adjustable DC Power Supply: 0 to 60V
The output voltage and current for the 7086 is shown simultaneously
on meters and course and fine control is provided with adjustable
current limit. For maximum output current see below.
Output: 0 to 60V 3A
Panel size: Width 168 x height 201mm
7087 Quad DC Power Supplies
The 7087 Quad DC Power Supply provides four fixed independent floating supplies.
The voltage and current ratings are 6V(8A), 12V(8A), 24V(4A), 48V(3A).
Each supply can be switched on/off individually and has its own fuse and power
LED. Output connections are industry standard 4mm shrouded sockets.
The supplies can be connected in series to obtain an alternative output voltage.
However, the current rating is that of the lowest rated supply.
Regulation: 6V, 0.3V at 8A: 12V, 0.2V at 8A: 24V, 0.15V at 4A: 48V, 0.2V at 3A
Ripple and Noise: 50mV or 1% pk-pk, whichever is greater
Over-volt protection: 1.25 x nominal voltage output
Current Overload: 1.4 x max current rating
Panel size: Width 80 x height 201mm
www.timeeusa.com
124
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
125
Bench Control Centre
7051 Multifunction Calibration System
 0-22V AC/DC, 0 – 220mA AC/DC
 0 - 1G ohm - decade steps
 10 MHz frequency
 Thermocouple Simulation/Measure 10 types
 RTD Simulation/Measure
 Digital Multi Meter 6½ digit - internal
 Simulated Resistance 10Ω to 40MΩ
 Pressure Calibration control software
 Hart/Fieldbus Compatible
 EasyCal Calibration software
Panel size: Width 425 x Height 201mm
 Touch Screen
Mounted centrally in the primary console the 7051 acts as a control centre for the whole bench. It
incorporates an industrial PC that is preloaded with the control programs and Time Electronics well
established EasyCal calibration software. Full control of Electrical, Temperature, Pressure, and Loop signals,
both in source and measure modes is available.
The control software allows a wide range of functions to be selected using mouse, keyboard, or touch
screen. Precise calibration is possible using the deviation function - this provides a direct error readout for
the instrument being calibrated.
The standard 7051 can calibrate, bench and handheld multi-meters, frequency meters, ohm meters, ac/dc
millivoltmeters, thermocouple indicators etc. With 7051 options added, resistance boxes, clamp meters,
temperature indicators/sensors, RTDs, power supplies, signal generators, ac/dc signal sources, timer
counters, oscilloscopes. For specifications and options see the 5051 (benchtop version) on page 78.
The 7051 includes a comprehensive package of options and
provides a lab ready solution. It comes equipped with every
item required for a complete calibration station:
DMM; Simulated Resistance; Touch Screen; Test Lead Set;
EasyCal; Printer and Connectivity Kit (As Shown).
A suite of calibration programs that simplify and speed up calibration.
If you have an instrument that needs calibrating against specification and
the results stored and printed, EasyCal is the answer.
A standard calibration library comprising of over 1000 procedures
covering a wide variety of instruments is included as standard.
Procedure templates for multi-meters, clamp meters, decade boxes,
insulation testers, and more can be used for creating any new
procedures as required.
Calibration certificates and reports to ISO 9001 quality standards
can be produced, along with re-cal reminders, job sheets and
calibration labels.
For features and capabilities see the EasyCal on page 82.
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
125
126
Pressure Modules
7062 Pressure Calibrator
Features a 4.5 digit display with 5 selectable pressure
units.
A pneumatic switch allows direct pressure input, regulator
output or vent control (not fitted on 20bar model).
See table 1, page 143 for units of engineering selection.
Fully integrated with the 7051 Control Centre and
EasyCal the user can define pressure calibration
procedures. Fully traceable calibration certificates can
be printed as required.
Panel size: Width 129 x Height 201mm
Specification
Range
Vacuum
0.2
2
5
10
20
Resolution (bar)
.001
0.01mb
.0001
0.001
0.001
0.001
Regulator
Yes
Yes
Yes
Yes
Yes
Yes
Accuracy % +/- 1 digit
0.04
0.1
0.04
0.04
0.04
0.04
Temp Stability
Less than 70 ppm per °C
Units
Bar, PSI, kPa, Mpa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm**
Maximum Pressure
2 x range. 1.5 x range for 20 bar
Sensor
Piezo-resistive – stainless steel diaphragm
Over press warning
1.2 x range full scale – audio and visual (on LCD) warning
Fittings
Quick Release
** Specify on ordering: 5 pressure units max
General Information and Options
Regulator Supply:
Maximum of 15bar for 0.2, 2, 5,10bar modules
Maximum of 30bar for 20bar modules.
Connections:
Quick release couplings
Panel size:
Width 129 x Height 201mm
Order code:
7062 / Pressure range option code
Pressure Options
www.timeeusa.com
126
7100 = 200mbar range
7101 = 2bar range
7102 = 5bar range
7103 = 10bar range
7104 = 20bar range
7111 = Vacuum regulator
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
127
Pressure Modules
7059 Pressure and Vacuum Calibrator
The 7059 features a 4.5 digit display with 5 selectable pressure units.
A pneumatic switch allows direct pressure input, regulator output or
vent control. It is suitable for engineers requiring a pneumatic
calibrator that offers a controlled transition between vacuum and
pressure settings.
In addition to the ranges shown below, specific customer needs can
be catered for: For example a range from –100 to +120mb with a
regulator setting resolution of 0.1mb.
Separate pressure and vacuum ports are also provided on the rear of
the console.
For units of engineering selection see table 1, page 143.
Fully integrated with the 7051 Control Centre and EasyCal the user
can define pressure calibration procedures. Fully traceable calibration
certificates can be printed as required.
Panel size: Width 129 x Height 201mm
Specification
Range
Vacuum
0.2
2
5
10
Resolution (bar)
.001
0.01mb
.0001
0.001
0.001
Regulator
Yes
Yes
Yes
Yes
Yes
Accuracy % +/- 1 digit
0.04
0.1
0.04
0.04
0.04
Temp Stability
Less than 70 ppm per °C
Units
Bar, PSI, kPa, Mpa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm**
Max Incoming Pressure
Maximum of 17bar (250psi)
Sensor
Piezo-resistive – stainless steel diaphragm
Over press warning
1.2 x range full scale – audio and visual (on LCD) warning
Fittings
Quick Release
** Specify on ordering: 5 pressure units max
General Information and Options
Connections:
Quick release couplings
Panel size:
Width 129 x Height 201mm
Order code:
7059 / Pressure range option code
Pressure Options
www.timeeusa.com
7100 = 200mbar range
7101 = 2bar range
7102 = 5bar range
7103 = 10bar range
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
127
128
Pressure Modules
7064 High Pressure Calibrator
Features a 4.5 digit display with 5 selectable units.
External line pressure (pneumatic) is connected to the
console rear panel.
Output pressure is controlled by a non - relieving type
regulator, with Bleed and Block needle valves used to vent
and isolate the output port. All connections are Minimess
high-pressure type.
For units of engineering selection see table 1, page 143.
Fully integrated with the 7051 Control Centre and EasyCal
the user can define pressure calibration procedures.
Panel size: Width 200 x Height 201mm
Specification
Range
35
70
100
200
Resolution (bar)
0.01
0.01
0.01
0.01
Regulator
Yes
Yes
Yes
Yes
Accuracy % +/- 1 digit
0.04
0.04
0.04
0.1
Temp Stability
Less than 70 ppm per °C
Units
Bar, PSI, kPa, Mpa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm**
Maximum Pressure
1.5 x range
Sensor
Piezo-resistive – stainless steel diaphragm
Over press warning
1.2 x range full scale – audio and visual (on LCD) warning
Fittings
Minimess
** Specify on ordering: 5 pressure units max
General Information and Options
Panel size:
Width 200 x Height 201mm
Order code:
7064 / Pressure range option code
Pressure Options
www.timeeusa.com
128
7105 = 35bar range
7106 = 70bar range
7107 = 100bar range
7108 = 200bar range
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
129
Pressure Modules
7065 Calibration Precision Pressure Indicator
Features a 4.5 digit display with 5 selectable pressure units.
For use with pneumatic up to 20bar and hydraulic/pneumatic up to 600bar.
Input connection is standard quick release or minimess high-pressure type
above 20bar.
For units of engineering selection see table 1, page 143.
Fully integrated with the 7051 Control Centre and EasyCal the user can
define pressure calibration procedures.
Panel size: Width 96 x Height 201mm
Specification
Range
Vacuum
Resolution (bar)
.0001
Accuracy % +/- 1 digit
0.04
0.2
2
5
0.01mb .0001 0.001
0.1
0.04
0.04
Temp Stability
10
20
35
70
100
200
400
600
0.001
0.001
0.01
0.01
0.01
0.01
0.1
0.1
0.04
0.04
0.04
0.04
0.04
0.1
0.1
0.1
Less than 70 ppm per °C
Units
Bar, PSI, kPa, Mpa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm**
Maximum Pressure
2 x range, 1.5 x range for 20 bar and above
Sensor
Piezo-resistive – stainless steel diaphragm
Over press warning
1.2 x range full scale – audio and visual (on LCD) warning
Fittings
Minimess (> 20 bar) and Quick Release (< 20 bar)
** Specify on ordering: 5 pressure units max
General Information and Options
Connections:
Quick release coupling for 0.2 to 20 bar ranges.
Minimess coupling for 35 to 600 bar ranges.
Panel size:
Width 96 x Height 201mm
Order code:
7065 / Pressure range option code
Pressure
Options
www.timeeusa.com
7100 = 200mbar range
7101 = 2bar range
7102 = 5bar range
7103 = 10bar range
7104 = 20bar range
7105 = 35bar range
7106 = 70bar range
7107 = 100bar range
7108 = 200bar range
7109 = 400bar range
7110 = 600bar range
7111 = Vacuum regulator
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
129
130
Pressure Modules
7038 Multifunction Precision Pressure Indicator
Features a 4.5 digit display with up to 9 selectable Pressure units depending
on what pressure range is chosen,Loop current can also be displayed in mA,
or as a percentage of span (4-20mA).
A min/max logging function (pressure or loop current) is provided. The min or
max values can be recalled to the display and if required can be viewed in real
time.
An additional feature is leak rate display. This allows the actual leakage rate to
be observed in real time in the selected ‘pressure units’ per sec, or per min.
Input connection is standard quick release or minimess high pressure type.
For units of engineering selection see table 1, page 143.
The 7038 is fully intergratable with the 7051 control centre and Easycal
The user can define pressure calibration procedures.
Panel size: Width 100 x Height 201mm
Specification
Range
Vacuum
Resolution (bar)
.0001
Accuracy % +/- 1 digit
0.04
0.2
2
5
0.01mb .0001 0.001
0.1
0.04
0.04
Temp Stability
10
20
35
70
100
200
400
600
0.001
0.001
0.01
0.01
0.01
0.01
0.1
0.1
0.04
0.04
0.04
0.04
0.04
0.1
0.1
0.1
Less than 70 ppm per °C
Units
Bar, PSI, kPa, Mpa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm**
Maximum Pressure
2 x range, 1.5 x range for 20 bar and above
Sensor
Piezo-resistive – stainless steel diaphragm
Over press warning
1.2 x range full scale – audio and visual (on LCD) warning
Fittings
Minimess (> 20 bar) and Quick Release (< 20 bar)
** Specify on ordering: 9 pressure units max
General Information and Options
Connections:
Quick release coupling for 0.2 to 20 bar ranges.
Minimess coupling for 35 to 600 bar ranges.
Panel size:
Width 100 x Height 201mm
Order code:
7038 / Pressure range option code
Pressure
Options
www.timeeusa.com
130
7100 = 200mbar range
7101 = 2bar range
7102 = 5bar range
7103 = 10bar range
7104 = 20bar range
7105 = 35bar range
7106 = 70bar range
7107 = 100bar range
7108 = 200bar range
7109 = 400bar range
7110 = 600bar range
7111 = Vacuum regulator
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
131
Pressure Modules
7066 Differential pressure calibrator module
Pneumatic – The connection is made via two font panel quick release
connector ports. These are available for differential pressure input (Hi
and Lo ports).
Electrical - The 7066 is powered from an internal power supply located
in the console.
Optional: Vacuum regulator and rear panel connection.
The regulator is for vacuum and can be configured to supply the
differential pressure on the negative side of the 7066 differential
pressure module. The regulator must in turn be supplied by a primary
high vacuum electric pump (not supplied) – this should be connected via
the console rear. The level of vacuum achievable will depend on the
efficiency of the Primary Pump.
Panel size: Width 150 x Height 201mm
Specification
Range
Resolution (bar)
Vacuum
0.2 bar
2 bar
5 bar
10 bar
0.001 mbar
0.01 mbar
0.1 mbar
0.001 bar
0.001 bar
0.04
0.1
0.04
0.04
0.04
1.9999 bar
5.000
10.000
Accuracy % +/- 1 digit
Full scale
199.99 mbar
Temp Stability
100ppm per °C
Units
Bar, PSI, Kg/Cm2, inHg, mmHg, KPa, cmWg. **
Linearity
0.02% of full scale
Maximum Static Pressure
20bar
Sensor
Piezo-resistive – stainless steel diaphragm
Over press warning
1.2 x range full scale – audio and visual (on LCD) warning
Fittings
Quick Release
** Specify on ordering: 5 pressure units max
General Information and Options
Panel size:
Width 150 x Height 201mm
Order code:
7066 / Pressure range option code
Pressure Options
www.timeeusa.com
7100 = 200 mbar range
7101 = 2 bar range
7103 = 10bar range
7111 = Vacuum regulator
Tel: 516-723-9909
CALIBRATION BENCHES
7102 = 5bar range
Email: [email protected]
131
132
Pressure Modules
7084 Pneumatic Line Pressure Controller
The 7084 is used for management of internal line pressures. The
external line pressure is connected to the console rear panel (the
maximum permitted pressure depending upon the version
ordered). The regulator used is of the self-relieving type and sets
the internal line pressures to the calibration modules.
Multiple 7084’s can be fitted to provide a choice of pressures
simultaneously. The 60mm Gauge displays the internal regulated
line pressure. The external line pressure can be isolated using a
needle block valve on the front panel. Direct output of the internal
line pressure is also available on the front panel via Minimess or
Quick Release connectors.
Panel size: Width 150 x Height 201mm
Specification
Gauges
Regulators
63mm anti-shock analogue
Pneumatic self-relieving. Maximum input pressure 400bar, depending on regulator
Output pressure range
See pressure options below
Fittings
Line input port
Minimess and Quick release
Rear of console. Quick release 5bar; minimess or NPT for 35 and 70bar options.
Front panel output port
Same connection options as line input port
Valve
Swagelok needle isolation valve on line input port
General Information and Options
Panel size:
Width 150 x Height 201mm
Order code:
7084 / Pressure range option code
Pressure Options
www.timeeusa.com
132
7102 = 5bar range
7105 = 35 bar
Tel: 516-723-9909
CALIBRATION BENCHES
7106 = 70 bar
Email: [email protected]
133
Pressure Modules
7032 Automatic Pressure Calibrator
The 7032 is a low cost programmable pressure
calibrator module that features a 4.5 digit display
with 5 selectable pressure units. It is designed to
speed up routine calibration of pressure gauges,
indicators and pressure transmitters. The user
presets the required calibration points, usually 0%,
25%, 50%, 75%, 100% of full scale – these are
generally considered most useful. However for
example, 0%, 10%, 50%, 70%, 95% could be used.
The output line can be vented either by pressing the
vent button or selecting zero on the regulator switch
to enable zero checking. Output pressure is
displayed on the 4.5 digit LCD display.
Panel size: Width 340 x Height 201mm
Manual operation
The 7032 can be controlled manually from a front panel, which allows immediate selection of any of the preset calibration pressures.
PC (7051) controlled operation – EasyCal
The 7032 is connected to the 7051 Console Controller and automatic calibration is possible. Using EasyCal,
Time Electronics universal calibration software, the calibration procedure can be fully automated. Procedures
can be written for pressure gauges, indicators, and pressure transmitters. The results of the calibration are
automatically stored on the 7051, and can be printed on demand. Closed loop calibration of pressure
transducers can be fully automated by implementing transmitter read-back using the 7051’s internal DMM.
Specification
Range
Vacuum
0.2
2
10
.0001
0.01mb
.0001
0.001
Regulator
Yes
Yes
Yes
Yes
Accuracy % +/- 1 digit
0.04
0.1
0.04
0.04
Resolution (bar)
Temp Stability
Less than 70 ppm per °C
Units
Bar, PSI, kPa, Mpa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm**
Maximum Pressure
2 x range
Sensor
Piezo-resistive – stainless steel diaphragm
Over press warning
1.2 x range full scale – audio and visual (on LCD) warning
Fittings
Minimess (>20 bar) & Quick Release (<20 bar)
** Specify on ordering: 5 pressure units max
General Information and Options
Power Supply:
Internal to Calibration Bench Console
Panel size:
Width 340 x Height 201mm
Order code:
7032 / Pressure range option code
Pressure Options
www.timeeusa.com
7100 = 200mbar range
7101 = 2bar range
7103 = 10bar range
7111 = Vacuum regulator
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
133
134
Loop and Temperature Modules
7079 Loop Ancillaries Calibrator
The 7079 provides the following for the testing and calibration of electrical
process loop signals.
0 to 199.99mA Measurement
To measure current connect the 7079 in series with the circuit under test. The
display will now show the current flow in the circuit together with the polarity.
Continuity
To test for circuit continuity connect the circuit under test in series with the 7079
continuity terminals. If a circuit exists a audible and visual alarm will sound. The
threshold for this test is approximately 100 ohms.
Output 24V
A separate isolated 24VDC supply is provide to enable the powering up of 4 20mA loops for the instrumentation under test. This output is overload protected
with an auto re-settable fuse. In the event of an overload allow the fuse to cool
for a few minutes before further use.
An RS232 port is provided for connection to an EasyCal control port. EasyCal
can readback the loop current on demand to allow automatic calibration of
pressure transmitters.
Panel size: Width 96 x height 201mm
7068 RTD Temperature Calibrator
The 7068 Resistance Temperature Detector (RTD) is a Microprocessor-based
calibrator. The calibrator is capable of accurately simulating and measuring
the most commonly used RTD probes, which facilitates the calibration of
process RTD input instruments without the need for expensive probes and the
use of slow temperature baths.
If used with a certified probe the unit performs as a highly accurate
thermometer. Readout is available in oC, oF and oK.
The 7068 is specifically designed to automate and to speed up the task of
calibrating instrumentation used in the process control industry. Simply enter
in engineering units (oC; oF or oK ) the desired zero and span values and the
calibrator will automatically calculate the standard five calibration points (0, 25,
50, 75 and 100%).
Panel size: Width 107 x height 201mm
www.timeeusa.com
134
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
135
Loop and Temperature Modules
7067 Loop Calibrator
The 7067 is a micro-processor based instrument for the calibration of voltage
and current loop signals. It can operate in three modes:
a) Loop current/voltage source (simulating a transmitter and the loop supply)
b) Sink of loop current (simulating a transmitter)
c) Measurement of loop current/voltage (simulating a loop indicator).
Display is via a dot matrix LCD screen. User input is by 7 front panel buttons.
Source functions are a) Manual step, b) Auto step c) Ramp. In step function
there are five calibration points, 0%, 25%, 50%, 75% and 100% of span. In ramp
function the output ranges between 0% and 100% of span the ramp rate and
dwell time are user programmable.
In source mode the range can be user programmed for any values between 0mA
to 50mA, or 0V to 21V. For example a low point of 10mA and a high point of
50mA could be set giving a span of 40mA
In measure mode only fixed ranges are available. Current and voltage is
displayed in 5-digit format in mA or Volts. Alternatively the current may be
displayed in % of span.
An automatic power-down feature is incorporated and turns the unit off after
approximately 7 minutes if no buttons are pressed. If required the automatic
power-down feature can be disabled in the user set-up.
Panel size: Width 97 x height 201mm
7069 Current Voltage Loop Calibrator
The 7069 is a current, voltage, and loop calibrator that meets the needs of R&D
labs and process control engineers. It provides source and measure functions in
three ranges, plus a transmitter simulator/sink function. Accuracy is 0.02% of
span with a display resolution of 4.5 digits.
Output modes include steps and ramps. No menus to learn, just switches and
buttons. A multi-turn potentiometer controls coarse output adjustment while
increment/decrement buttons are provided for fine control. The source output
can be reversed (+/-) and zeroed at the flick of a switch. The front panel features
a large easy-to-read 4.5 Digit LCD display that auto-ranges to allow the ranges
to be extended by 10% above the normal 0.2/2.0/20 full scale. Manual reset of
the ramp function is also provided for quick restore.
When used as a source the output can be zeroed and reversed to enable the
calibration of centre-zero type voltage or current instruments e.g. –10V to 0 to
+10V.
If the unit is not operated for approximately 15 minutes, it will automatically
power down. If required this feature can be disabled in the user set-up.
Panel size: Width 97 x height 201mm.
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
135
136
Loop and Temperature Modules
7085 Temperature Distribution Panel
Has a range of different types of thermocouple and 4
wire RTD. Both simulate and measure mode
calibration is available. To simplify thermocouple
calibration the Cold Junction Compensation (CJC)
temperature is displayed in clear easy-to-read digits.
Fully integrated with the 5051 Control Centre and
EasyCal, the user can define both thermocouple and
RTD temperature calibration procedures.
Panel Size: Width 250 x height 201mm
7077 Temperature & Process Calibrator
 Measure/Simulate 8 thermocouples
 Measure/Simulate PT100
 ITS 90 standard
 Measure/Source (uV/mV/mA)
 Display in °C and °F
 Automatic CJC – selectable
 10 point memory recall
 Inching and Step functions
 Process loops 4-20mA and 0-50mA
 24V loop drive voltage
Panel size: Width 295 x height 201mm
The 7077 is a high performance process calibrator that combines source and measurement functions for
thermocouples, PT100s, uV, mV, and mA.
Thermocouple measurement and simulation
Measure and simulate the temperature and mV characteristics of J, K, T, R, S, B, N and E thermocouples.
Cold junction compensation:
The module can be operated with or without internal cold junction compensation.
PT100 measurement and simulation:
Based on 0.3850 alpha probe standard. Range is –200 °C to 700 °C.
Measurement and Source (uV, mV, and mA):
Measurement ranges are 0 to +/-30mV and 0 to +/-60mA. Source ranges are 0 to +/-80mV and 0 to +80mA.
Temperature units selection:
The display can be easily changed from °C to °F. The equivalent uV (thermocouples) and ohms (PT100) can
also be shown.
24V Process Loop drive mode:
A process loop can be driven at 24V and up to 60mA by selecting the ‘Milliamp Source’ mode and setting it at
60mA (or a lower level if required).
Inching (Incrementing/Decrementing):
The unit has a general-purpose inching function. This adjusts the output in fixed increments of temperature
(thermocouples only) or voltage or current. The set-up menu gives a the user a choice of three levels of
increment i.e. 0.1, 1 or 10 for °C/°F, or 1, 10, or 100 uV/uA for voltage/current. The lowest of these
represents the highest setting resolution and provides the most precise control of the output. This is
especially useful for calibrating thermostat controllers that have tight specification on hysteresis.
Memory recall and step/auto-step functions:
Up to 10 values can be stored in the unit’s non- volatile memory and they can be recalled at any time. The
user can also manually step through them in sequence using the step key. Continuous stepping (auto-step)
is also available at any user selectable rate between 1 and 10 seconds/step.
For full specifications see the 1090 (handheld version) on page 90.
www.timeeusa.com
136
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
137
Loop and Temperature Modules
7061 Multifunction Process Calibrator
 Measure (3 ranges) up to 400V, 400mA, 40kΩ
 Output Volt. (3 ranges) up to 10V, 1uV res.
 Output Curr. (3 ranges) up to 20mA, 1uA res.
 Output Resistance: 0-400Ω, 0.01Ω res.
 Thermocouple measure & simulate:
J, K, T, E, R, S, B, N

RTD measure & simulate: PT100

Ramp function
Panel size: Width 285 x height 201mm
The 7061 is a comprehensive microprocessor controlled temperature and loop control calibrator. It is the
latest version of the series and incorporates high performance digital technology.
The 7061 is primarily designed to perform calibration of thermocouple and resistance thermometer
input/output instruments.
In addition, the calibration and measurement of volts, millivolts, milliamps and ohms can be performed.
Features and Functions
Input signals are connected via 4 sets of terminals, which can be switched by the system to measure
thermocouples, volts, milliamps and resistance thermometers. The terminals can be configured for use in
many different configurations, e.g. 4 wire resistance thermometers or twin thermocouples.
The output section is galvanically isolated from the input section, thus allowing the unit to perform
calibrations on both the input and output of the same instrument without regard for common mode voltages,
which could otherwise upset the calibration results.
The output section can source volts and milliamps, and simulate thermocouples and PT100 resistance
thermometers via a pair of terminals. The input and output values are displayed simultaneously on a large
alphanumeric LCD display.
In addition to conventional functions and ranges, this section provides special ramp and Tx features to
enable automatic calibration of loops. The operational parameters of these functions are set-up using menu
driven procedures.
For full specifications see the 7050 (transportable version) on page 94.
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
137
138
Custom Design Modules
The Time Electronics CalBench is not limited to standard modules. Both the primary and secondary
consoles can be fitted with various instruments specifically for customer requirements.
5075 DMM Module
Modules can be designed from the
Time Electronics range; decade
boxes, portable calibrators, and
benchtop instruments can all be
configured.
Multifunction Calibrator and DMM
modules are fully compatible with
EasyCal software.
DC Power Supply Module
Non Time Electronics equipment such as
handheld multimeters, oscilloscopes, power
supplies, pressure calibrators, and more can
also be fitted into the bench consoles.
This allows the user to integrate a specific
instrument into the bench system. Switches,
power controllers, and communicator
modules can also be added.
Oscilloscope Module
www.timeeusa.com
138
3 Phase Power Controller
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
139
External Options
7070 / 7072 Dry block temperature calibrators
Provides a convenient precision temperature source for the calibration of industrial
thermometers. It is able to fully automate closed loop temperature calibration and can
be configured using Time Electronics EasyCal Software. The cold Junction
Compensation (CJC) temperature is available to allow correction for the ambient
temperature.
Temperature ranges:
-17 to +140 °C or +33 to +650 °C
Power requirements:
230VAC, 115VAC, 320VA maximum.
Size/Weight:
L 241 x W 139 x H 325 mm. 7070 – 7kg, 7072 – 6kg
7090 Pneumatic Calibration Pump
This is hand operated and ideal for pneumatic calibration work from Vacuum (-950mbar)
to 40bar and features adjustable volume chamber.
It comes complete with a set of hoses, adapters and a carrying case. A digital pressure
gauge which locates on the top of the pump body is available as an optional extra.
7089 and 7096 Digital Pressure Gauges
Can display pressure in bar, mbar/hpa, kPa, MPa and PSI, the user can set the
zero reference or use factory default. Maximum and minimum pressures can be
stored. Features an auto turn – off function, which can be disabled. The supplied
battery life is about 1000 hours in normal measuring mode.
Accuracy: 0.2% FS typical.
7095 Hydraulic Calibration Pump
Hand operated for hydraulic calibration work from 0 to 700bar. It comes complete
with hoses and a carrying case. A digital pressure gauge that locates on the top of
the pump body is available as an optional extra.
7096: Optional digital pressure gauge. Features see above.
7097 Minimess test kit
A selection of items from the Minimess 1620 series connectors used on the
high-pressure calibration modules. The kit includes In-line tees for 1/4”, 3/8”
and 1/2” BSP, and a capped Minimess / 1/4” BSP test point enabling easy
quick connection to most pressure systems.
Also included are two reducing bushes, male to female, 1/2” / 1/4” BSP and
3/8” to 1/4” BSP. 3 Dowty washers, a gauge adaptor, one Microbore hose
and a cloth wipe.
The whole kit comes in a convenient plastic case, with cut outs for gauges if
required. The adaptors are made of mild steel.
Dimensions: 272 x 230 x 81mm. (case closed), weight: 1.44Kg
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
139
140
Bench Extras
The Time Electronics Calibration Bench is a custom-made unit with a full range of extras. A number of fittings
and extras are available. Shown below are some examples:
Perforated Back Panel with Tool Hooks
Perforated Back Panel Extras
Under Worktop Fittings
More fittings, tools, and Lab Equipment are available upon request. This includes:
Tools
ESD equipment
Lab Equipment
 Soldering/de-soldering stations
 Laminated tabletops
 Bench stools or chairs
 Vices , Vacuum pumps
 Mats
 Clamp meters
 Grounding kits
 Pull-out keyboard tray
 Magnifying lamps
 Wrist wraps
 Test lead sets and racks
 Lab Carts
 Printer kits, bar code readers
 ESD hand tools
www.timeeusa.com
140
Tel: 516-723-9909
CALIBRATION BENCHES
 Document holders
 Palm and forearm supports
 Top mount monitor arm
Email: [email protected]
141
Laboratory Design
In addition to the CalBench Time Electronics offers a complete laboratory design service. A full range of
equipment is available to build a comprehensive testing facility, offering versatility and full utilization of
workspace.
Storage Units
Drawers, Cabinets, Dividers, and Inserts
Tables, Workbenches, Shelving, Mountings, and Lighting
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
141
142
Laboratory Design
Wall and Frame Mounted Perforated Panels with Options
Mobile Equipment
Tool and Equipment Cases
www.timeeusa.com
142
Tel: 516-723-9909
CALIBRATION BENCHES
Email: [email protected]
143
Reference Tables
Engineering units to pressure Compatibility table
Unit of Pressure
Vacuum
200mb
2bar
5bar
Table 1
10bar 20bar 35bar
70bar 100bar 200bar 400bar 600bar
bar
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
PSI
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
kPa
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
inWg
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
cmWg
yes
yes
yes
yes
yes
yes
no
no
no
no
no
no
inHg
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
mmHg
yes
yes
yes
yes
yes
yes
no
no
no
no
no
no
Kg/cm2
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
atm
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
Mpa
no
no
no
no
no
no
no
no
no
no
yes
yes
Regulator
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
CalBench Quick-Guide Specifications Table
Table 2
Console Dimensions
Overall:
Primary Console:
Secondary Console:
Width 200 x height 156 x depth 85cm, 175Kg typical. With secondary console fitted height is 166cm.
Width 200 x height 29 x depth 47cm, 90Kg typical.
Width 192 x height 40 x depth 19.5 cm, 30Kg typical.
Individual module height 201mm standard, Individual module width shown in brackets.
Power Modules
7082 Mains Power Controller (270mm)
7083 Dual 24V DC Supply (131mm)
7086 Adjustable DC Power Supply (168mm)
7087 Quad DC Power Supplies (80mm)
7088 Power Unit (350mm)
7051 Multifunction Calibrator and Control Centre (425mm)



0-22V AC/DC, 0 – 220mA AC/DC
0 – 1GΩ - decade steps
10 MHz frequency



Digital Multi Meter 6½ digit – internal
Simulated Resistance 10Ω to 40MΩ
RTD Simulation/Measure



Thermocouple Simulation/Measure 10 types
EasyCal Calibration Management Software
Touch Screen
Options: Hi Voltage/Current AC/DC1050V/22A (9782), Oscilloscope calibration (9775), Capacitance / Inductance (9798),
Clamp meter adapter (9780), Tacho Meter adapter (9773), and Test lead set (9796).
Pressure Modules
Available Units of Measure: Bar, PSI, kPa, MPa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm.
Pressure Range Option Codes: 200mbar (7100), 2bar (7101), 5bar (7102), 10bar (7103), 20bar (7104), 35bar (7105), 70bar (7106), 100bar
(7107), 200bar (7108), 400bar (7109), 600bar (7110), Vacuum Regulator (7111).
Module and Description
7062 Pressure Calibrator (129mm)
7064 High Pressure Calibrator (200mm)
7065 Pressure Indicator (96mm)
7038 Multifunction Pressure Indicator (100mm)
7066 Differential Pressure Calibrator (150mm)
7032 Automatic Pressure Calibrator (340mm)
Range (bar)
Accuracy (%)
VAC, 2, 5, 10, 20
0.04
0.2
0.1
35, 70, 100
0.04
200
0.1
VAC, 2, 5, 10, 20, 70, 100
0.04
0.2, 200, 400, 600
0.1
VAC, 2, 5, 10, 20, 70, 100
0.04
0.2, 200, 400, 600
0.1
VAC, 2, 5, 10
0.04
0.2
0.1
VAC, 2, 10
0.04
0.2
0.1
Fittings
Quick release
Minimess
Under 20bar Quick release
Over 20bar Minimess
Under 20bar Quick release
Over 20bar Minimess
Quick release
Quick release
7084 Pneumatic Line Pressure Control (150mm) Regulator sets the internal line pressures to the calibration modules: 5, 35, 70bar
Temperature and Loop Calibration Modules
7085 Temperature Distribution Panel (250mm)
7079 Loop Ancillaries Calibrator (96mm)
7068 RTD Temperature Calibrator (107mm)
7061 Multifunction Process Calibrator (285mm) 7069 V-I Loop Calibrator (97mm)
www.timeeusa.com
Tel: 516-723-9909
CALIBRATION BENCHES
7067 Loop Calibrator (97mm)
Email: [email protected]
143
144
Product Index
1006 Handheld DC Millivolt Source - 0.02% Accuracy ........................................................................................ 4
1007 Handheld DC Millivolt Potentiometer & Source (0.02% Accuracy).............................................................. 6
1010 Transportable DC Voltage Calibrator (0.02% Accuracy) ............................................................................. 8
1017 Transportable DC Multifunction VIR Calibrator (0.005% Accuracy) .......................................................... 14
1021 Handheld DC Current Source With Null Meter (0.02% Accuracy)............................................................. 10
1024 Transportable DC Current Calibrator with Null Measuring (0.02% Accuracy) ........................................... 12
1030 Microcal - Handheld Voltage & Current Source ........................................................................................ 16
1040 Resistance Box (1Ω - 100MΩ).................................................................................................................. 38
1041 Resistance Box Low Ohm (0.01Ω - 1kΩ)................................................................................................. 39
1044 Handheld DC Voltage and Current Calibrator (0.05% Accuracy) .............................................................. 18
1048 Handheld V-I Loop Calibrator (0.02% Accuracy) ...................................................................................... 20
1049 Handheld PT100 Simulator Handheld (Class A °C) .................................................................................. 22
1050 Handheld PT100 Simulator Handheld (Class A °F) .................................................................................. 23
1051 Resistance Box Low Ohm (0.01Ω - 1MΩ) ............................................................................................... 40
1053 Inductance Box (1mH - 10H) .................................................................................................................... 52
1061 Resistance Box Low Cost (1Ω - 1.2MΩ) ................................................................................................... 41
1065 Resistance Box - Power 10W (0.1Ω - 100kΩ) .......................................................................................... 42
1067 Resistance Box Precision Low Ohm (10mΩ - 12kΩ) ................................................................................ 43
1070 Capacitance Box (100pF - 10uF).............................................................................................................. 50
1071 Capacitance Box (10pF - 100uF).............................................................................................................. 51
1077 Handheld Milliamp Transducer/Line Simulator (Transim) ......................................................................... 24
1090 Handheld Temperature and Process Calibrator........................................................................................ 26
5011 Resistance and Temperature Calibrator (1Ω - 120MΩ) ............................................................................ 70
5018 Programmable DC/AC Voltage/Current Calibrator.................................................................................... 72
5025 Multifunction Calibrator ............................................................................................................................. 76
5033 High Precision Programmable DC Power Source - 3 Channel ................................................................. 60
5045 Oscilloscope and Timer/Counter Calibrator .............................................................................................. 74
5051 Multifunction Calibration System .............................................................................................................. 78
5065 6.5 digit Bench Multimeter ........................................................................................................................ 54
5068 Inscal - Insulation Tester Calibrator (100kΩ - 10GΩ) ................................................................................ 33
5069 Inscal - Insulation Tester Calibrator (100kΩ - 100GΩ) .............................................................................. 34
5070 DuctorCal - Calibrator for Ductor Testers and Micro-Ohm Meters ............................................................ 35
5075 Precision Digital Multimeter ...................................................................................................................... 56
5077 Power Calibrator (PowerCal) .................................................................................................................... 62
5080 Pat Cal 2 - Calibrator for PAT's and Insulation Testers............................................................................. 36
7000 Handheld RTD Temperature Calibrator .................................................................................................... 92
7005 Handheld Loop Calibrator ....................................................................................................................... 116
7006/7007 Loop-Mates 1 and 2 (Handheld Simulator & Indicator) .................................................................. 118
7010 Transportable Pressure Calibrator (Single Channel) .............................................................................. 102
7015 Transportable Pressure Calibrator (Dual Channel) ................................................................................. 104
7016 Transportable Pressure Calibrator (Single Channel with Regulator)....................................................... 106
7018 Transportable Differential Pressure Calibrator ........................................................................................ 108
7040 Handheld Digital Pressure Calibrator ..................................................................................................... 100
7050 Process and Thermocouple Calibrator ..................................................................................................... 94
7080 Calibration Bench and Module Options .................................................................................................. 119
7090 Vacuum & Pressure Calibration Pump (-950mbar to 40bar) ................................................................... 110
7095 Hydraulic Pressure Calibration Pump (0 to 700bar) ................................................................................ 111
9747 EasyCal Calibration Software ................................................................................................................... 82
9820 Benchtop Programmable Resistance Low Ohm (0.1Ω - 100kΩ)............................................................... 48
9840 Series Power Calibrators (Single and 3 Phase) ........................................................................................ 64
Due to continuous development Time Electronics reserves the right to change specifications without prior notice.
www.timeeusa.com
144
Tel: 516-723-9909
INDEX
Email: [email protected]
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project