Owner's Manual

Remote Control Liquid Propane Gas Patio Fireplace

For Outdoor Installation & Operation

Model 89795

US

,/_

WARNING:

Read this Owner's Manual carefully and be sure your patio fireplace is properly assembled, installed and maintained.

Failure to follow these instructions could result in serious bodily injury and/or property damage. This patio fireplace is not intended to be installed in or on recreational vehicles or boats.

Note to installer: Leave this Owner's Manual with the consumer after delivery and/or installation.

Note to Consumer: Leave this Owner's

Manual in a convenient place for future reference.

1 PC3611000LRev: 2004/2/13

I, I.3F.X;JI[m

Warranty

Safety Instructions

................................

2

................................

2

Contents for Hardware Pack & Packing List ........... 5

Parts Diagram ................................. 6

Parts List for Replacement ................................. 7

Assembly & Installation Instructions .................... 8

Checking for Gas Leaks .............................. 11

Reading the Manifold Pressure .............................. 11

Operating Instructions

Maintenance

..............................

11

..............................

12

Error Messages

Electric Wire & Block Diagram

Specifications & Dimensions

..............................

12

................. 13

............................... 14 m;l

Full 1-Year Warranty on fireplace

For one year from the date of purchase Grand Hall

Enterprise Co., Ltd. will repair or replace, at our option, any patio fireplace parts(except for paint loss, rusting and Replacement Batteries) that is defective in material or workmanship.

You will be charged for shipping and handling. This warranty does not cover labor charges.

This warranty does not include:

• Batteries of controller and remote.

• Reshaping or dents in Reflector that may be caused by, but not limited to, falling debris.

Warranty Service

Warranty service is available by calling 1-888-317-7642

8am - 8pm CST, Monday through Friday.

Warranty Restrictions

• This warranty applies to the original purchaser only.

e

This warranty is void if patio fireplace is used for commercial or rental purposes.

e

This warranty is void if the Burner or Valve assembly has been altered or disassembled.

e

This warranty applies only if this patio fireplace is used in the United States.

e

This patio fireplace is for use with Liquid

Propane(LP) gas only. Any attempt to convert this fireplace to natural gas is dangerous and will void your product warranty.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

This appliance has been tested to and complies with IAS

4-96 "IAS REQUIREMENTS FOR OUTDOOR GAS

FIREPLACES".

Installation must conform with local building codes, or in the absence oflocat building codes, with the National Fuel Gas Code, ANSI Z223.1 NFPA 54 or CAN/CGA-B149.1,

Installation Code.

Natural Gas and Propane

/_

WARNING:

For outdoor use

only

2

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury, death or property damage and will void your product warranty.

Read the installation, operation and maintenance instructions thoroughly

installing or servicing this equipment.

before

/_ WARNING

Failure to comply with these instructions could result in a fire or explosion that could cause serious bodily injury, death or property damage.

A strong gas smell, or the hissing sound of gas indicates a serious problem with your fireplace or LP tank. Failure to immediately follow the steps listed below could result in a fire or explosion which could cause serious bodily injury, death or property damage.

WHAT TO DO IFYOU SMELLGAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use the phone in your building.

Immediately call your gas supplier from a neighbor's phone.

Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Z_ WARNING

Do not use this fireplace to burn solid fuels or trash.

Never place matches, paper, garbage, or any other material on top of logs or into the flame.

Z_ WARNING

Do not use this fireplace if any part of the control system has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace the parts of the control system and gas control which has been under water.

Z_ WARNING

Very hot while in operation

Never lean over the fireplace while using your fireplace.

Do not touch Lid or Screen while the fireplace is in operation, or until the fireplace has cooled down after use.

Failure to comply with these instructions may result in serious bodily injury.

WARNING: Installation and service must be performed by a qualified installer, service agency orthe gas supplier,

Fig 1 Minimum clearance from combustibles.

//_ WARNING

(a) Do not store a spare LP-gas cylinder near this fireplace.

(b) Never fill the cylinder beyond 80 percent full.

(c) If the information in"(a)" and "(b)" is not followed exactly, a fire causing death or serious injury may occur.

FOR YOUR SAFETY

1. Do not store or use gasoline or other flammable material and liquids in the vicinity of this fireplace or other appliance.

2. ALP cylinder not connected for use must not be stored in the vicinity of this or any other appliance.

IMPORTANT; This fireplace is only for use with LP type of gas as equipped from the manufacturer and is not convertible for use with other gases.

IMPORTANT; This fireplace may not be used for preparing food. Gases and/or food particles may fall into the appliance and inhibit proper operation.

Important safety rules:

YOUNG CHILDREN should be carefully supervised when they are in the area of the fireplace.

NEVER hang anything including clothes or other flammable items on the fireplace.

The screens installed in this fireplace must be in place at all times when in operation to prevent foreign objects from entering the unit.

For proper ventilation around the unit, do not obstruct the upper and lower vent louvers.

The fireplace should be inspected before first use and at least annually by a qualified service person. More frequent cleaning may be required depending on area conditions.

Keep burner and control compartment clean.

See installation and operating instructions.

1 Clearance from combustibles:

Proper clearance from combustible materials must be maintained at all times (See Fig 1 for minimum clearance)

Combustible materials include wood, compressed paper, plant fibers, plastic, plexiglass or other materials capable of being ignited and burned.

Such materials shall be considered combustible even though flameproof, fire-retardant treated or plastered. Additional clearance may be required for glass, painted surfaces and other materials which may be damaged by radiant or convection heat.

Unit to walls: 24 Inches

Unit to ceiling: 24 Inches

24inches

2. The gas inlet supply and normal operating manifold pressure for fireplace is as follows. For gas supply line pressures in excess of 14 "W.C., consult with your representative or the factory.

Type of Gas

Maximum inlet pressure

Minimum inlet pressure

Manifold pressure

Gas Rating

Liquid Propane

14 "W.C.

11 "W.C.

9 "W.C.

41,000 BTU/hr

3. The fireplace must be inspected before each use and annually by a qualified service person.

AIt gas connections should be checked for leaks utilizing a soap solution. Never use a flame for this purpose.

The flame pattern should be visually checked whenever the fireplace is operated.

You r fireplace area must be kept clear and free of combustible materials, gasoline and other flammable vapors and liquids.

Clean your fireplace only with noncombustible, non-corrosive cleaning agents.

4. Your fireplace has been designed with several safety features as follows.

A thermal fuse for overheating cut-off protection.

Flame failure shut off.

Automatic ignition.

Safety combination valve shut off.

The operating condition is controlled and diagnosed by a micro processor.

The micro processor is an advanced feature which also makes it easy for one touch operation with remote control or manual push button.

Any modification to the fireplace not described in the installation instructions may compromise the safety of this fireplace and will void the warranty.

3

IMPORTANT; Your Homestead patio fireplace cannot be converted to use Natural Gas. Attempting to do so is extremely hazardous and wilt also void the warranty.

Correct LP Gas Tank Use

The patio fireplace is designed for use with a standard

20 lb. Liquid Propane Gas (LP Gas) tank, not included in box. Never connect your fireplace to an LP gas tank directly without regulator that exceeds this capacity. A tank of approximately 12 inches in diameter by 18-1/2 inches high is the maximum size LP gas tank to use. You must use an "OPD" gas tank which offers a listed

Overfill Protection Device.

This safety feature prevents tank from being overfilled which can cause malfunction of LP gas tank, regulator and/or fireplace.

The LP gas tank must be connected and marked in accordance with the specification for LP-gas cylinders of the U.S. Department of Transportation (D.O.T) or the

National Standards of Canada, CAN/CSA-B339,

Cylinder, Spheres and Tubes for Transportation of

Dangerous Goods, and Commission, as applicable.

1. The LP gas tank has a shutoffvalve, terminating in an

LP gas supply tank valve outlet, that is compatible with type 1 tank connection device. The LP gas tank must also have a safety relief device that has a direct connection with the vapor space of the tank.

2. The tank supply system must be arranged for vapor withdrawal.

3. The LP gas tank used must have a collar to protect the tankvalve.

This patio fireplace isnot intended to be installed in or on recreational vehicles and!or boats.

Never connect an unregulated LP gas tank to your fireplace. The gas regulator assembly supplied with your fireplace is adjusted to have an outlet pressure of 11" water column(W.C.) for connection to an LP gas tank.

Only use the regulator with hose assembly supplied with your fireplace.

Replacement regulator with hose assembly must be those specified by manufacturer.

Have your LP gas tank filled by a reputable propane gas dealer and visually inspected and re-qualified at each filling.

Never fill the gas tank beyond 80 percent full. Have your propane gas dealer check the release valve after every filling to ensure that it remains free of defects.

Always keep LP gas tanks in upright position. Do not store(or use) gasoline or other flammable vapors and liquids in vicinity of this fireplace.

LP gas tanks not connected for use must NOT be stored inside of fireplace or in the vicinity of this or any other gas appliance.

Do not subject the LP gas tank to excessive heat.

Never store an LP gas tank in the garage or other indoor location. Always disconnect the LP gas tank first and store it safety outside.

LP gas tanks must be stored outdoors in a wellventilated area and out of the reach of children.

Disconnected LP gas tanks must not be stored in a building, garage or any other enclosed area.

When your fireplace is not in use the gas must be turned off at the gas tank.

The regulator with hose assembly can be seen when you open the doors. It should be inspected before each use of the fireplace.

If there is excessive wear or any abrasions, or if the hose is cut, it must be replaced prior to the fireplace being used.

Keep the gas regulator hose away from hot surface.

Avoid unnecessary twisting of hose.

Visually inspect hose prior to each use for cuts, cracks, excessive wear or other damage.

If the hose appears damaged do not use the fireplace.

Call

1-888-317-7642 for an authorized replacement hose.

Never allow children to play near your fireplace.

4

Thefollowingtableillustrates variousstagesofassembly.

Ref. No.

$115G03082

$115G03082

$115G03082

$313G03062

Component

Screw, 3/16"-24 UNC

Screw, 3/16"-24 UNC

Screw, 3/16"-24 UNC

Nut, 3/16"-24 UNC

Qty.

4

4

16

16

Usage

Assemble the Screen onto Base

Assemble the Lid onto Screen

Assemble Screen

Assemble Screen

Screw, 3/16"-24 UNC

Qty. 24

Parts # $115G03082

©

Nut, 3/16"-24 UNC

Qty. 16

Parts # $313G03062

For complete installation and assembly you should have:

1. Base including Burner, Controller, Regulator with Hose

2. Screen

3. Lid

4. Log set (3 pieces)

5. Clinker (30 pieces) and Ember glow (1 pack)

6. Remote control

7. Battedes/D (4 pieces)

5

1.Lid

2.Screen

3.LogSet

4. ClinkerSet

5.EmberGlow

6.CarrierAssembly

7.ControlPanelBox

8.CasterShaft

9.Casterwithwelded

10.RemoteControl,_

16.ElectricI

17.AirFilter

18.OrificewithNut

19.ControlAssembly

(Includes

Y"

Control _"

20.BurnerExtens

21.PilotGasTube

28.FrontPanel

29. Regulator with Hose

WARNIN( for this product, Only the same replacement can work for this product.

30. Side Panel, Right

31. Side Panel, Left

32. Wheel

6

11.BurnerBase

12.PilotAssembly

13.Burner

22.ControlBoxDoor

yCompartment

23.BatteryCover

24.ControlBoxDoorLock

26.TankFixingBracket

27.TankFixingPlate

33. Door/Rear

34. Door Handle

35. Door Magnet

36. Base

34

35

36

---

30

31

32

33

---

16

17

18

19

20

21

22

23

24

25

26

27

28

29

Ref # Description

1 Lid

2 Screen

12

13

14

15

3

4

7

8

5

6

9

10

11

Log Set (3 pieces)

Clinker Set (30 pieces)

Ember Glow (1 pack)

Carrier Assembly

Control Panel Box

Caster Shaft

Caster with Welded Seat

Remote Control

Burner Base

Pilot Assembly

Burner

Log Supporter

Burner Plate

Part #

PC3800005F

PC3700002F

PC1500000M

PC1600000G

PC1700000G

PC3901000P

PC0711000E

PC6001000F

PC4701000F

PC2011000E

PC6211000F

PC0811000F

PC1300000A

PC5301000F

PC640O000F

Electric Ignitor

Air Filter

Orifice with Nut

Control Assembly

Burner Extension Tube

Pilot Gas Tube

Control Box Door

Battery Cover

Control Box Door Lock

Knob/Control Box

PC0311000E

PC6500000S

PCl111000C

PC5811000Z

PC5911000S

PC1211000A

PC6311000F

PC5611000F

$233G03041

PC5211000P

Tank Fixing Bracket

Tank Fixing Plate

Front Panel

PC5511000F

PC5411000F

PC4801000F

Regulator with Hose PC0100000A

(This item is especially designed for this product. Only the same replacement can work for this product.)

Side Panel, Right PC5101000F

Side Panel, Left

Wheel 5"

Door/Rear

PC5001000F

PC4001000P

PC4101000F

Door Handle

Door Magnet

Base

Hardware Pack

Owner's Manual

PC4201000P

PC4901000F

PC4401000F

PC3501000F

PC3611000L

1

2

1

1

1

2

1

1

1

1

1

4

1

1

1

1

1

1

1

1

1

1

Qty.

1

4

1

1

1

1

1

1

1

1

1

1

1

1

1

1

For repair or replacement parts you need: Call

1-888-317-7642

To make sure you obtain the correct replacement parts for your fireplace, please refer to the part numbers on this parts list. The following information is required to ensure you receive the correct parts: l. Modelnumber foundon C.S.A. labellocatedonthesurfaceofbackcover.

2. Part Number

RefertoFig.

1.

3. Part Description

4. Quantity of parts needed

Important: Keep this Owner's manual for convenient referral and for part replacement.

Important: Use only manufacturer authorized parts. The use of any part that is not manufacturer authorized can be dangerous and will also void your product warranty.

Fig. 1

Door!Rear

CSA Label located on

Eye protection

Protective gloves

Phillips screwdriver

Adjustable Wrench

7

CAUTION:

it is possible for one person to assemble this fireplace, obtain assistance from another person when handling some of the larger, heavier pieces, especially base assembly.

Before assembling the fireplace, use the parts list to check that all necessary parts have been included. Inspect the fireplace for damage as you proceed. Do not assemble or operate the fireplace if it appears damaged. If you have questions during the assembly process call 1-888-317-7642.

Remove all parts and hardware from carton. Refer to the parts list and hardware pack illustrations and assemble the fireplace on a protective work surface to avoid scratching the surfaces.

LockerA

Locker B

Tip for movement

Push Locker Aand lifta handle.

Push Locker B and pull the handle forward.

H Assemble four screens onto the Base Assembly

1. See _ provided.

Align the hole at the Screen A with the hole on the Base Assembly. Tighten securely using screw

2. See _r_ Align the hole on Screen B with the hole on the Base Assembly. Tighten securely using screw provided. NOTE: Screen A should be positioned inside of Screen B as shown.

3. Repeat step 2 to assemble the Screen C and D onto the Base assembly.

4. See _ Insert the screw provided intothe hole on Screen B and align. Insert the screw through the hole in

Screen A. Tighten the provided nut securely.

5. Repeat step 4 on the other three Screens.

Screw 3/16"-24 UNC

Qty. 20

Ref. #$115G03082

©

Nut 3/16"-24 UNC

Qty. 16

Ref. #$313G03062

Screen

8

H Arrange the Log Set on the Base assembly

1. See _

2. See _

3. See _

Position the Log-A on the Log Supporters-c and d, then hold a branch of Log-A by a finger.

Position the Log-B on the Log Supporter-b, and hold branch of LogsAand B by finger.

Position the Log-C on the Log Supporter-a.

NOTE: Keep space in the center between each Log for rising flame.

4. See _ Place the Clinkers evenly around the burner.

5. See _ Place the Ember Glow Chips over the burner plate.

Log

Suppo_er-_

Log

Suppo_er* b

....

Log

Suppo_er*c

Log

Suppo_er*d

E!

Connecting a LP gas tank to the Fireplace

1. Open the Rear Door and Inspect the parts for damage as you proceed. Do not assemble or operate the fireplace if it appears damaged.

2. Place a 20 lb cylinder tank with foot ring into the mounting hole of base propedy. Make sure the tank valve is in

OFF position. (Turn clockwise to close) See

3. See _r_ Unlock the Tank Fixing Lever and move the Gas Fixing Bracket down to hold the gas tank.

4. See _ Lock the Tank Fixing Lever.

5. Check the tank valve to insure it has proper external mating threads to fit the hose & regulator assembly provided. (Type 1 connection perANSI Z21.58b-2002)

6. Inspect the valve connection port and regulator assembly. Look for damage or debris. Remove any debris.

Inspect hose for damage. Never use damaged or plugged equipment.

7. When connecting the regulator assembly to the tank valve, hand tighten nut clockwise to a full stop. See I-_1_1

DO NOT use a wrench to tighten because it could damage the Quick Coupling Nut and result in a hazardous condition.

8. Open the tank valve fully(counter clockwise). Use a soapy water solution to check all connections for leaks before attempting to light your fireplace. See "Checking for Gas Leaks" on page 11. If a leak is found, turn the tank valve off and do not use your fireplace until the leak is repaired.

Disconnecting a LP gas tank from the Fireplace

1. Turn the fireplace off and turn LP gas tank valve to the full OFF position. (Turn clockwise to close.)

2. Detach the hose and regulator assembly from the LP gas tank valve by turning the Quick Coupling Nut counterclockwise.

CAUTION: When the fireplace is not use, the gas must be turned off at the supply tank.

9

Tank Fixing Lever

Tank Fixing Bracket

Counter clockwise

El

Quick k co ,p,,o0

°I

Recheck the Log Set and assemble the Lid

1. Recheck the Log Set, Clinker and Embers to be sure that they are positioned properly.

2. Align the 4 holes in the Lid with the 4 holes at the screen assembly. Fix firmly by using four screws provided.

See mL'_l_l I

_ t.'i i

Screw 3/16"-24 UNC

Qty. 4

Ref. #$115G03082

El To install or replace the Batteries

1. Open the Rear Door, turn Locker counter clockwise to unlock and pull the cover of the Battery Case to open.

See _ Place 4 Batteries/D provided into the Battery Case. Make sure the polarity of the Batteries is right as shown in

2. Replace the cover on the battery case and close Rear Door.

__

Battery Case

Battery Case

Cover

Battery Case lO

Congratulations

Your LP Patio Fireplace is now ready for use. Before the first use and at the beginning of each season (and whenever the LP gas tank has been changed):

1. Read all safety, Lighting and operating instructions.

2. CheckGasValveOdfices, BumerTubeforanyobstructions.

3. Perform gasleakcheckaccording toinstructionsfound on page 11 ofthis manual.

Never test for leaks with a flame. Prior to the first use, at the beginning of each season, or every time your LP gas tank is changed, you must check for gas leaks. Follow these four steps;

1. Make a soap solution by mixing one part liquid detergent and one part water.

2. Make sure the status of heater is off, then turn the gas ON at source.

3. Apply the soap solution to all gas connections, especially apply to Inlet/manifold pressure tap on the gas valve after reading the pressure.

Bubbles will appear in the soap solution if

connections are not properly sealed. Tighten or repair as necessary.

If you have a gas leak that you cannot repair, turn off the gas at the source, disconnect fuel line from your fireplace and call 1-888-317-7642 assistance.

for repair

4. Do not attempt to light the automatic pilot by hand

(match, cigarette, lighter etc.)

mm

WARNING: THESE PROCEDURES MUST BE

PERFORMED BY QUALIFIED

SERVICEAGENCYORTHE

INSTALLER,

GAS SUPPLIER.

1. Manifold pressure and Inlet pressure can be checked by applying an 1/4" rubber hose to the protruding outlet tap on the combination valve.

2. Loosen the small screw 2 to 3 turns counterclockwise.

3. Connect the 1/4" rubber hose to outlet gas pressure tap with manometer.

4. Read the pressure on the Manometer.

5. Seal tap afterwards by tightening the small screw.

_,,.

Rubber Hose

Outlet gas pressure tap

_..GAS

Note : At first use the housing may emit a slight odor

and smoke due to the burn off of oil used in the manufacturing process. This is to be expected.

1. Famitiadzeyourselfwith the safety instructions and warnings at the front of this manual. Do not smoke while lighting the fireplace or checking gas supply connections.

Be sure your fireplace is installed in accordance with the minimum clearance from combustibles as shown on page 3 of this manual.

2.

Make sure ait connections are securely tightened.

A. Turning the fireplace ON

Open Door and slowly open valve on gas tank.

Press the ON/OFF button to operate the fireplace. The

Status indicator light will illuminate green. Refer to Fig. 1.

After approximately 5 seconds the automatic spark will light the burner and the status indicator light will illuminate red after detecting the flame by microprocessor.

Notes: If the fireplace does not ignite on the initial try, the spark will stop and the indicator light wilt blink two times.

To attempt to re-ignite press the ON!OFF button again to cancel the error condition.

Then press the ON/OFF button again to operate.

Your fireplace will not operate when the error message is indicated.

This process may need to be repeated several times on the initial start up because of air in the

LP supply line and whenever a 20 lb LPG tank is replaced or if the gas line is disconnected from the fireplace for any reason.

The status indicator light will turn off after approximately

30 seconds to save battery power.

Fig. 1

UP Button

Status indic

DOWN But

/OFF Button

To adjust the burning level:

Press UP or DW button to adjust the burning level to maximum, middle and minimum level.

Se_o moor

Inlet gas pressure tap

11

B. Turning the fireplace off

Press ON/OFF button to turn fireplace off.

Close valve on gas tank and close Door.

Note: If the fireplace does not turn off by pressing the

ON/OFF button, close the manual valve on the main gas line. Have the fireplace checked by a qualified service technician.

C. Operating Remote Control

TO turn the fireplace on:

Open Door and slowly open valve on gas tank.

Press the ON button on remote control for 2 or 3 seconds to activate. The Status indicator light on control wilt illuminate green and the control box on the fireplace will sound one beep. Refer to Fig. 1.

TO turn the fireplace off:

Press the OFF button on the remote control for 2 or 3 seconds to activate. The control box on the fireplace will sound two beeps. Refer to Fig. l u

Close valve on gas tank and close Door.

To adjust the burning level:

Press UP or DW button on the remote control. The control box on the fireplace will sound two beeps. Refer to Fig. 1.

When controlling your fireplace by remote control, press button on the remote control for 1 or 2 seconds to send signal to fireplace.

Fig. 1

ON button

DOWN button _

- Signal indicator

OFF button

UP button

Trouble Shooting

To replace the battery,

Remove the screw on the back of the remote control.

Remove the front cover and replace the battery with an

Alkaline type MS21iMN21 size 23Ai12V. Refer to Fig. 2.

Fig. 2.

PCB_

Terminal

Battery m

Remedy

\

\

\

\

\

Strongwind X

Dead Battery X

Airin gas line

Gas odor

Non-ignition x

No gas flow X

Retry Ignition

Replace Batteries

Purge air

X Service call

Service call

Tank empty, Manua gas valve closed,

Service call

I l'i'to

The fireplace is controlled by a micro processor which has the ability to check its own operation continuously. If a fault occurs an error message will appear on the status indicator on the control panel and the micro processor will automatically shut off the heater.

If an error message is displayed please refer to the list below for the possible cause of the error message and the Trouble Shooting Section on this page for a solution.

You may be able to fix the problem without a service call.

If the error message persists turn off the gas at the manual shutoff and contact a qualified service technician for service.

Ignition Failure:

The status indicator light will flash red for 15 seconds with single consecutive flashes. Check gas flow and all gas connections.

If the problem continues call a qualified service technician.

Flame Failure:

The status indicator light will flash red for 15 seconds with two consecutive flashes. Check gas supply, LP tank.

If the problem continues call a qualified service technician.

Over Heating:

The status indicator light will flash red for 15 seconds with three consecutive flashes. Check for obstruction of air flow around fireplace casing.

If the problem continues call a qualified service technician.

Gas valve Failure:

The status indicator light will flash red for 15 seconds with four consecutive flashes. Check connections of gas valve. If the problem continues call a qualified service technician.

The fireplace requires very little maintenance.

To clean simply wipe the outer case with a damp cloth. Do not use solvents or any other caustic cleaning agents because they may discolor or distort any plastic parts. Do not use aerosol polish or any other flammable material to clean the heater while it is in operation.

12

f

[] M ×/Mi

_

Status

_ Indicator

Bakery Case

Thermal - Fuse

127'C/260'F

Remarks

1. Color Table

BK : black

BR : brown

R : red

O : orange

Y : yellow

G : green

BL : blue

2. Draw based on

Component Side

I

I

I

I

Servo Motor Assembly

Chassis _

////

Thermocouple

GND =-

If any original wires supplied with the appliance must be replaced, it must be replaced with type 18AWG n

600V 105 'C wire or its equivalent.

]

Control PCB

ON/OFF UR DOWN Switch & Status indicator

]

* Remote Control_

__

Servo Motor

Pilot t

Therma( Fuse t27 'C/260'F (250W2A~)

Electric ignitor

Chassis

The[mocoup(e

Chassis

GV, Main

13

Model No.

Gas Control

Gas Input

Used Gas

Max. inlet pressure

Min. inlet pressure

Manifold pressure

Main injector size

89795

Electronic Control with Micro-Processor

41,000 BTU!hr

Liquid Propane Gas

"14 "W.C.

"11 "W.C.

9 "W.C.

#47

Gas Inlet

Burner

Ignitor

Electrical Supply

* After tank regulator

5/8"-18 UNF

Cast - Iron Ring Burner

Electronic Spark

4 Batteries/D, 6 VDC

Includes Remote Control

Battery type for Remote control: Alkaline type MS21/MN21 size 23At12V

Diameter of Lid

Depth of Base

Width of base

Height

: 28.9 inches

: 25.3 inches

; 21.7 inches

: 50.0 inches

Made in China

Exported by: Grand Hall Enterprise Co., Ltd.

9'th FL, No. 298, Rueiguang Rd., Neihu, Taipei, Taiwan (114)

14

f

110 mm

-_ Electric Wire Diagram

Ballery Case

Ren_arks

1 Color

BK

BR

Table

: black

: brown

R

O

Y

G

BL

2 Draw

: red

: oraP_ge

: yellow

: green

: blue based

Component

* Optional Part on

Side

Servo Motor Assembly Chassis7_

Thermocouple

GND

If any original wires supplied with the appliance must be replaced, it must be replaced with type 18AWG, 600V, 105 'C wire or its equivalent.

PC3011000L

* All Text black color bottom PANTONE 427 C

o

E

E

Model No.

Injector size

Gas Inlet

* After tank requiator.

il meswad

'........

89795

4 Batteries/D

Input Rating for control

Gas Type

Gas Input(Max.)

Gas Inlet Pressure(Max.)

Gas Inlet pressure(Min.)

Manifold Pressure

Liquid Propane/LPG

41,000 Btu/hr

"14 "W.C.

"11 "W.C.

9 "WC.

#47

5!8" - 18 UNF

Serial No.

I

Lot No,

L

IAS U.S. 4-96 Outdoor Gas Fireplace. Made in China

®

U_

Used gas: Liquid Propane Only

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury, death or property damage and will void your product warranty. Refer to the

Owner's Manual provided with this appliance.

For assistance or additional information consult a qualified installer, service agency or the gas supplier.

CAUTION(LP-gas): The gas pressure regulator provided with this appliance must be used. This regulator is set for an outlet pressure of 11 inches water column.

CAUTION: The gas supply must be turned off at the LP-gas supply cylinder when this appliance is not in use.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO, IF YOU SMELL GAS:

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use the phone in your building.

• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplieCs instructions.

• If you cannot reach your gas supplier, call the fire department.

Lighting instructions:

Toturn ON:Turn cylinder valve ON.

Press the ON/OFF button to operate the fireplace.

The Status indicator light will illuminate green.

After approximately 5 seconds the automatic spark will light the burner and the status indicator light will illuminate red.

Press ON/OFF button to turn fireplace off.

Turncylinder valve OFF.

See Owner's Manual pages 11 and 12.

Minimum clearance from combustibles

Unit to walls: 24 Inches

Unittoceiling: 24 Inches

For Installation on(or over) Noncombustible Floors Only

PC4311000L

U m

8'"

Z mg oQ

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement