- Home
- Do-It-Yourself tools
- Power tools
- Harbor Freight Tools
- 47907
- Assembly And Operating Instructions
Harbor Freight Tools 47907 Assembly and Operating Instructions
Add to my manuals8 Pages
Harbor Freight Tools 47907 is a versatile shallow well pump designed for domestic and agricultural water supply, irrigation, and other water transfer applications. With its powerful 3/4 HP motor, it can deliver up to 898 gallons of water per hour and has a maximum suction depth of 26 feet. It features a durable PVC housing, a 5-gallon pressure tank, and a maximum pressure of 75 PSI. Its compact size and lightweight make it easy to transport and install.
advertisement
SHALLOW WELL PUMP
3/4 Horsepower, PVC Housing
Model 47907
ASSEMBLY and OPERATING INSTRUCTIONS
®
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our Web site at http://www.harborfreight.com
Copyright © 2002 by Harbor Freight Tools ® . All rights reserved. No portion of this
manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools .
For technical questions and replacement parts, please call 1-800-444-3353
Motor
Discharge Size
Maximum Flow
Maximum Suction Depth
Maximum Lift
Overall Dimensions
Pressure Tank Capacity
Maximum Pressure
Tank Hose Length
Weight
Specifications
120 Volt, 60 Hz, 4 Amps (start-up)
Single Phase, 3400 RPM
1” Diameter
898 GPH
26 Feet
140 Feet
19” H x 10-5/8” W x 17-1/2” Long
5 Gallons
75 PSI
10 Inch
28-3/4 Lbs.
Save This Manual
You will need the manual for the safety warnings and precautions, assembly instructions, operating and maintenance procedures, parts list and diagram. Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Keep the manual and invoice in a safe and dry place for future reference.
Safety Warnings and Precautions
WARNING: When using tool, basic safety precautions should always be followed to reduce the risk of personal injury and damage to equipment.
Read all instructions before using this tool!
1.
Keep work area clean. Cluttered areas invite injuries.
2.
Observe work area conditions. Do not expose this pump to rain or direct immersion.
Don’t expose to rain. Keep work area well lighted. Do not use electrically powered tools in the presence of flammable gases or liquids.
3.
Keep children away. Children must never be allowed in the work area. Do not let them handle Pump.
4. Use the right pump for the job. Do not attempt to force a small Pump to do the work of a larger industrial Pump. There are certain applications for which this Pump was designed. It will do the job better and more safely at the rate for which it was intended.
Do not modify this Pump and do not use this Pump for a purpose for which it was not intended.
5.
Dress properly. Do not wear loose clothing or jewelry as they can be caught in moving parts. Protective, electrically non-conductive clothes and non-skid footwear are recommended when working. Wear restrictive hair covering to contain long hair.
6.
Use eye and ear protection. Always wear ANSI approved impact safety goggles and ear protection.
7.
Do not overreach. Keep proper footing and balance at all times. Do not reach over or across running machines.
8.
Maintain Pump with care. Keep Pump clean for better and safer performance.
Inspect tool cords periodically; If damaged, have them repaired by a qualified technician.
SKU 47907 For technical questions, please call 1-800-444-3353.
Page 2
9.
Disconnect power. Unplug Pump when not in use.
10. Stay alert. Watch what you are doing, use common sense. Do not install Pump when you are tired.
11. Check for damaged parts. Before using Pump, any part that appears damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment and binding of moving parts; any broken parts or mounting fixtures; and any other condition that may affect proper operation. Any part that is damaged should be properly repaired or replaced by a qualified technician.
12. Guard against electric shock. Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures.
13. Replacement parts and accessories. When servicing, use only identical replacement parts. Use of any other parts will void the warranty. Only use accessories intended for use with this tool. Approved accessories are available from Harbor Freight
Tools.
14. Do not install Pump if under the influence of alcohol or drugs. Read warning labels on prescriptions to determine if your judgment or reflexes are impaired while taking drugs. If there is any doubt, do not install the Pump.
15. Use proper size and type extension cord. If an extension cord is required, it must be of the proper size and type to supply the correct current to the tool without heating up.
Otherwise, the extension cord could melt and catch fire, or cause electrical damage to the tool. This tool requires use of an extension cord of 0 to 10 amps capability (up to
50 feet), with wire size rated at 18 AWG. Longer extension cords require larger size wire. If you are using the tool outdoors, use an extension cord rated for outdoor use
(signified by “WA” on the jacket).
16. Maintenance. For your safety, maintenance should be performed regularly by a qualified technician.
Warning: People with pacemakers should consult with their physician(s) before using this product; operation of equipment in close proximity to a heart pacemaker could cause interference or failure of the pacemaker.
Warning! Never operate this pump if the power cord or electrical components are damaged or the seals are compromised. Never plug in the power cord when wet or standing on damp or wet ground. Exercise extreme caution when working with electrical equipment in the presence of water to maintain your personal insulation to avoid shock.
Do not allow others in the work area when working with electrical equipment. Use GFCI outlets when using this pump.
Note: Performance of this tool (if powered by line voltage) may vary depending on variations in local line voltage. Extension cord usage may also affect tool performance.
Warning: The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
SKU 47907 For technical questions, please call 1-800-444-3353.
Page 3
Unpacking
When unpacking, check to make sure the parts listed on pages 7 and 8 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number on the cover of this manual as soon as possible.
Installation
Note: For intake and discharge hose locations, see FIGURE 1 on page 5.
Note: If power cords must be extended, only use no less than UL approved, 18 Gauge wire.
Do not extend the wires more than 50 feet.
1.
Install the pump on a rigid, level platform above the water level. This platform must provide a solid, level surface that is capable of supporting the weight of the pump, and attached piping filled with water. Never allow the pump to become immersed in water.
2.
The level of the intake port should not be more than 12-15 feet above the water. Pumping efficiency falls off as the height above the water level increases.
3.
Keep the vertical lift that the pump must move water before discharge at a minimum. Vertical delivery above a few feet will degrade pump efficiency.
4.
The intake port must have a screen
(not included) attached to prevent introduction of debris into the pump. At the end of the discharge pipe, either purchase a pre-made screen to fit, or wrap loose screen and secure with wire.
5.
Lay out the intake and discharge pipes with as few turns as possible to prevent air pockets within the lines. Air pockets interfere with pressure switch performance.
Typical Installation
Discharge
Pump
Intake
6.
Intake and discharge pipes must have a minimum of 1” to 1-1/4” diameter. Systems with larger vertical components should have larger diameter piping. Keep in mind that the maximum vertical lift (total vertical distance from the inlet screen to the discharge outlet) is 140 feet.
7.
For your protection, the power outlet used should have a Ground Fault Circuit Interrupter
(GFCI). Have it installed by a qualified electrician. Keep the power line safely away from water.
8.
The inlet and discharge lines should not be wedged or stressed in a way that puts strain on the pump. Do not support the pump with the inlet and discharge lines.
9.
This is a self starting pump that uses a pressure switch. Once the power cord is connected, the pump can start at any time. Do not handle or perform maintenance on the pump if the power cord is plugged in.
SKU 47907 For technical questions, please call 1-800-444-3353.
Page 4
Priming Valve Inlet
FIGURE 1
Discharge
Intake
Shaft
Air Valve
(not visible)
Pressure Meter
Note: Compression Tank (#1A) has a
Rubber Bladder (51) inside. This Bladder must be pumped up with between 18 and
19 PSI of air at all times. On the end of the Compression Tank opposite the side with the Pressure Meter, is an air valve located under a cover. Remove the cover over the air valve and periodically monitor this air valve with an air pressure gauge to ensure that the Rubber Bladder (51) maintains the required 18 to 19 PSI.
Operation
Warning! Never pump liquids containing abrasive materials such as sand. Never pump flammable, corrosive, or volatile liquids.
Warning! Never plug in the power cord when wet or standing on damp or wet ground. Do not plug in the power cord until step number 3 below.
1.
Make sure the intake pipe is fully submerged before operating the pump.
2.
Gently insert a screwdriver into the motor shaft and make sure the shaft turns freely.
(See Figure 1)
3.
Important Note: Before starting the pump for the first time, prime it by pouring clean
water into the Priming Valve Inlet (see Figure 1). If water leaks from the drain valve underneath the pump, securely close it and refill the unit.
4.
To begin pumping, plug in the power cord.
SKU 47907
REV 06i, REV 07g
For technical questions, please call 1-800-444-3353.
Page 5
Problem
The pump won’t start
The pump operates but it won’t discharge water
Pump has low capacity
Troubleshooting
Cause
No power
Solution
Check connections
Blocked Impeller Free the motor shaft
Pressure switch disconnected Check gauge
Thermal Protection cut out Allow pump to cool
Inlet tube not submerged
Air in suction pipe
Inlet screen clogged
Lifting height exceeded
Inlet pipe is too small
Liquid is too dirty
Lift height exceeded
Tank’s rubber bladder underinflated.
Submerge the inlet
Check pipe and seals
Clean screen
Reduce lifting height
Increase pipe diameter
Clean screen frequently
Reduce lift height
Inflate to 18-19 PSI
Never disassemble the pump or motor as this will damage the water seals. All repairs should be performed by a qualified technician.
Maintenance
Always disconnect pump from power source before attempting any maintenance.
1.
Clean the inlet screen regularly to remove accumulated debris.
2.
Use pressure gauge to test pressure in Tank’s Rubber Bladder (51). Pressure should range between 18 and 19 PSI.
3.
Wipe the pump clean with a soft, damp cloth with soapy water. Do not use solvents. Do not get the electrical components wet.
4.
If storing the pump for a long time, store it in a dry location, and apply a light layer of oil to the metal parts prior to storage, to inhibit rust.
5.
To drain the pump, disconnect the water lines and turn it upside down.
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS
MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES
ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED
TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY
PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES
THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
SKU 47907
REV 06i, REV 07g
For technical questions, please call 1-800-444-3353.
Page 6
6
7
4
5
P a r t
1
2
3
8
9
1 0
1 1
1 2
1 3
1 7
1 8
1 9
2 0
1 4
1 5
1 6
D e s c r i p t i o n
S c r e w M 8 x 1 2
M o t o r H o u s i n g
F a n B l a d e
R e a r C o v e r
S p r i n g W a s h e r
M o t o r B o l t M 5 x 1 2 5
S t a t o r
B e a r i n g
R o t o r
B e a r i n g
R u b b e r S h e a t h
S c r e w 4 .
2 x 1 5
C a b l e B l o c k
C a b l e S l e e v e
C o n n e c t i o n C a b l e
S c r e w 2 .
9 x 1 5
W a t e r p r o o f C o v e r
R u b b e r C o v e r
0 r i n g
C a p a c i t o r C o v e r
Parts List
4
1
1
1
Q t y .
4
1
1
1
2
1
1
1
1
1
1
1
1
1
1
4
3 7
3 8
3 9
4 0
3 3
3 4
3 5
3 6
2 8
2 9
3 0
3 1
3 2
P a r t
2 1
2 2
2 3
2 4
2 5
2 6
2 7
D e s c r i p t i o n
C a p a c i t o r
S i d e C o v e r
S w i t c h S e a l P l a t e
W a t e r p r o o f S w i t c h
S c r e w 3 .
5 x 2 0
H e x N u t M 8 x 2 0
F r o n t C o v e r
R u b b e r R i n g
0 r i n g
F l a n g e
I m m o b li e R i n g
M o t o r R i n g
I m p e ll e r
F l o w G u i d e P l a t e
0 r i n g
F l o w G u i d e A s s y .
0 r i n g
P u m p S h e ll
L g .
V a l v e C o v e r
0 r i n g
Assembly Drawing
4
1
1
3
Q t y .
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
SKU 47907
NOTE: Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts.
For technical questions, please call 1-800-444-3353.
Page 7
ASSEMBLY DRAWING
Note: When ordering a part from this drawing, you must include the suffix “A” with the number.
SKU 47907 For technical questions, please call 1-800-444-3353.
REV 08/05
Page 8
advertisement