Product brochure

Product brochure
Product
brochure
Air heating and
ventilation
LEO
Air curtains and air curtain-fan
heater combo units
ELiS
Ductless ventilation with
heat recovery
OXeN
We are experts in providing complete heating
and ventilation solutions for medium and big cubature buildings. Our offer consists of three main
product groups:
• air heating and ventilation:
fan heaters, gas heaters, electric heaters, mixing
chambers, fan heaters for specialized buildings like
chicken coops, pools, car washes,
• air curtains and air curtain-fan heater combo units,
• ductless ventilation with heat recovery:
OXeN ventilation units.
Design
ELiS DUO
air curtain-fan heater combo unit
FRONT VIEW
SCALE 1:5
1125
BASIC line
SIDE VIEW
SCALE 1:5
BOTTOM VIEW
SCALE 1:5
In 2014 we launched FLOWAIR BASIC brand as an
answer to the cheap lines of products available on
the market. Productivity and successfully completed negotiations with subcontractors allowed the
reduction of the costs of the selected devices, resulting in the creation of Basic Line. These are the
products for customers looking for a good price
on the market. At the same time FLOWAIR brand,
which promotes new line of products guarantees
their quality, reliability and advanced technical
solutions.
356
440
In our activity, we put special emphasis on innovative projects, taking into account industrial
design. Thanks to the knowledge that we draw
from design, we focus not only on aesthetics of
manufactured products, but primarily on the benefits that they have to carry. We pay special attention to ergonomics and functionality of solutions,
which will be tailored to the needs of users. Our
projects have been awarded in several prestigious
international competitions in the field of industrial
design, like The Red Dot Design Award, iF product design award and Dobry Wzór, organized by
Polish Institute of Industrial Design.
Achievements
Our greatest achievement are satisfied customers.
To achieve this goal we use innovative industrial
design.
We are constantly inspired by new technologies
and improvements in terms of functionality,
control and used materials, as well as custom
industrial design. Thanks to this for many years we
create new trends in the heating and ventilation
industry.
We are also recognized as a credible company in
terms of organization and financial and we arealready nine times awarded the title of Fair Play
Company.
2
www.flowair.com
Table of contents
AIR HEATING
AND VENTILATION
• LEO FB................................................................................................................. 8
• LEO D................................................................................................................17
• LEO FS.............................................................................................................20
LEO FB
• LEO INOX...................................................................................................25
• LEO EX............................................................................................................30
• LEO EL.............................................................................................................33
• LEO AGRO................................................................................................36
AIR CURTAINS AND AIR CURTAIN-FAN
HEATER COMBO UNITS
• ELiS C................................................................................................................42
• ELiS T.................................................................................................................46
• ELiS B.................................................................................................................50
• ELiS A................................................................................................................55
• ELiS DUO....................................................................................................60
• ELiS G................................................................................................................65
DUCTLESS VENTILATION WITH HEAT
RECOVERY
• OXeN.................................................................................................................72
Tel. + 48 58 627 57 20
Fax. + 48 58 627 57 21
e-mail: [email protected]
www.flowair.com
www.flowair.com
3
System FLOWAIR
is a pioneering solution that enables integration of operatin of heating and ventilation units and control their
operation with only one controller.
Innovative control SYSTEM makes possible to take
advantage of features that were previously reserved for
extensive building management system BMS.
ELiS DUO
air curtain-fan heater
combo units
T-box
intelligent controller
with touch screen
JUST ONE CONTROLLER is needed
• control of all units from one place
• quick access to operating parameters of the units
Cooperation
with BMS
4
Weekly
programmer
Read of
operation
parameters
Various
operation
modes
Intuitive
use
www.flowair.com
LEO
fan heaters
ELiS
air curtains
OXeN
ductless ventilation
with heat recovery
LEO D
destratificators
www.flowair.com
5
6
www.flowair.com
AIR HEATING
AND VENTILATION
www.flowair.com
7
Fan heaters LEO FB
Fan heaters LEO FB
Heating capacity [kW]
Air flow [m3/h]
Weight [kg]
Colour
Casing
2–100
150–8500
7,4–35,7
grey
EPP (expanded polypropylene)
Application:
Medium and big cubature buildings: industrial halls, warehouses, department stores,
production halls, sports halls, sacral buildings, etc., as well as smaller spaces such as:
workshops, garages, stores, car show rooms, gas stations, etc.
Available types of units:
LEO FB V
Fan heater with AC fan, with possibility of 3-step air flow regulation.
Indexes LEO FB V
Name
FB 10V F B 20V F B 30V FB 25V FB 45V FB 65V FB 95V
Index
10982
10983
10927
10919
10922
10925
10978
LEO FB M
Heater with energy-efficient fan with EC motor, controlled by external 0-10V signal,
enabling stepless regulation of fan speed in range of 0-100%.
Indexes LEO FB M
Name
Index
F B 10M FB 20M F B 30M FB 25M FB 45M FB 65M FB 95M
1 0984
10985
10928
10920
10923
10926
10976
Special attributes
3-STEP FAN
EC FAN
EPP CASING
CONDENSATE TRAY
— LEO FB 25|45|65
LEO FB V fan heaters are
equipped with 3-step fan. It is the
simplest and an effective way to
control operation of the heater.
Use of energy-efficient fan with
EC motor in LEO FB M fan heaters
allows reduction of energy costs
even by 50%.
Mechanical strength, resistance
to dirt, low weight and aesthetic
look – everything thanks
to EPP material (expanded
polypropylene).
LEO FB fan heaters can also be
used for cooling. Thanks to builtin tray, condensate can be easily discharged from the heat exchanger.
Dimensions
LEO FB 10|20|30
LEO FB 25|45|65
650
650
1180
440
355
580
560
580
480
550
LEO FB 95
0
330
8 LEO FB
350
Air heating and ventilation
Technical data
FB
FB
10V
10M
2100
FB
FB
20V
20M
2000
FB
FB
30V
30M
1900
FB
FB
25V
25M
4400
230/50
FB
FB
45V
45M
4100
FB
FB
65V
65M
3900
Max. current consumption [A]
0,5
0,25
0,5
0,25
0,5
0,25
1,4
0,7
1,4
0,7
1,4
0,7
Max. power consumption [W]
110
57,5
110
57,5
110
57,5
320
170
320
170
320
170
51
54
51
54
51
Max. air flow [m3/h]
Power supply [V/Hz]
IP
Max. acoustic pressure
level(1) [dB(A)]
Max. air stream range(2) [m]
Max. heating water temp. [oC]
Max. oprating pressure [MPa]
Weight of unit [kg]
Weight of unit filled with
water [kg]
(1)
(2)
FB
FB
95V
95M
8500
2x1,4
(2,8)
2x320
(640)
2x0,7
(1,4)
2x170
(340)
57
53
54
47
45
47
45
14,5
47
14,0
45
54
13,0
26,0
120
1,6
24,0
22,0
33,0
9,3
7,4
10,2
8,3
11,3
9,5
14,8
11,5
16,0
13,1
18,3
15,0
32,2
25,6
10,0
8,1
11,4
9,5
12,7
10,9
15,8
12,5
18,0
15,1
21,0
17,7
35,7
29,1
Acoustic pressure level at the distance of 5 m from the unit, in the room of medium capability of sound absorption and 1500 m3 of cubature
Range of horizontal isothermal air stream, at 0,5 m/s velocity limit
Installation
C
installation under the ceiling
vertical installation using the console
90°
45°
60°
Optional corner holders
Easy installation and leveling of the heater.
45°
B
60°
170°
A
Rotary console
Enables easy installation of the heater perpendicularly
or at various angles to the wall and 170° rotation.
Recommended installation distances [m]
FB 10
FB 20
FB 30
FB 25
FB 45
FB 65
FB 95
A
max. 3,0
max. 3,0
max. 3,0
2,5–8,0
2,5–8,0
2,5–8,0
2,5–10,0
B
2,5–5,0
2,5–5,0
2,5–5,0
2,5–10,0
2,5–10,0
2,5–10,0
2,5–12,0
C
Air heating and ventilation
min. 0,3
LEO FB 9
Heating capacities
LEO FB 10
LEO FB 20
LEO FB 30
LEO FB 25
LEO FB 45
LEO FB 65
LEO FB 95
V = 2100 m3/h
V = 2000 m3/h
V = 1900 m3/h
V = 4400 m3/h
V = 4100 m3/h
V = 3900 m3/h
V = 8500 m3/h
Tp1
PT
Qw ∆pw Tp2
PT
Qw ∆pw Tp2
PT
Qw ∆pw Tp2
PT
Qw ∆pw Tp2
PT
Qw ∆pw Tp2
PT
Qw ∆pw Tp2
PT
Qw ∆pw Tp2
°C
kW
l/h
kW
l/h
kW
l/h
kW
l/h
kW
l/h
kW
l/h
kW
l/h
kPa
°C
kPa
°C
kPa
°C
kPa
°C
kPa
°C
kPa
°C
kPa
°C
Tw1/Tw2 = 90/70°C
0
10,1 446
2,8
14,5 21,4 946 17,6 32,0 27,3 1202 14,3 42,5 26,7 1179 11,6 18,0 45,0 1986 15,2 32,5 65,5 2892 21,3 50,0 100,9 4449 41,0 36,0
5
9,5
2,4
18,5 20,1 887 15,7 34,5 25,5 1125 12,7 44,5 25,0 1101 10,2 22,0 42,1 1958 13,4 35,5 61,4 2712 18,9 51,5 96,2 4244 36,7 38,5
417
10
8,8
388
2,1
22,5 18,7 827 13,8 37,5 23,7 1047 11,1 46,5 23,2 1024 8,9
25,0 39,2 1730 11,8 38,0 57,3 2529 16,7 53,0 89,6 3955 32,2 41,0
15
8,1
358
1,9
26,5 17,4 768 12,0 40,5 22,0 970
9,7
49,0 21,4 946
7,7
29,5 36,3 1603 10,3 41,0 53,1 2344 14,5 55,0 83,0 3663 28,0 43,5
20
7,4
328
1,6
30,5 16,0 708 10,5 43,5 20,2 892
8,3
51,0 19,7 868
6,6
33,0 33,4 1475 8,8
43,5 48,9 2159 12,5 56,5 76,3 3369 24,0 46,5
Tw1/Tw2 = 80/60°C
0
8,6
377
2,1
12,0 18,4 810 13,7 27,5 23,3 1025 11,0 36,5 22,7 999
8,8
15,5 38,5 1693 11,7 27,5 56,5 2481 16,6 43,0 88,3 3881 32,0 31,0
5
7,9
347
1,8
16,0 17,1 751 12,0 30,0 21,6 947
9,6
38,5 21,0 921
7,6
19,0 35,6 1565 10,2 30,5 52,3 2300 14,4 44,5 81,8 3594 27,8 33,5
10
7,2
317
1,6
20,0 15,7 691 10,3 33,0 19,8 869
8,2
40,5 19,2 843
6,5
23,0 32,7 1437 8,7
33,5 48,2 2116 12,4 46,5 75,2 3304 24,0 36,0
15
6,5
287
1,3
24,0 14,3 631
8,7
36,0 18,0 791
6,9
42,5 17,4 765
5,4
26,5 29,8 1308 7,3
36,0 44,0 1931 10,5 48,0 68,5 3011 20,1 38,5
20
5,9
257
1,1
28,0 13,0 570
7,3
39,0 16,2 713
5,7
45,0 15,6 686
4,5
30,5 26,8 1179 6,1
39,0 39,7 1744 8,8
50,0 61,8 2716 16,7 41,5
Tw1/Tw2 = 70/50°C
0
7,0
307
1,5
10,0 15,4 675 10,2 23,0 19,4 848
8,1
30,5 18,7 819
6,3
12,5 32,0 1402 8,6
23,0 47,3 2071 12,3 36,0 74,0 3236 23,6 26,0
5
6,3
277
1,3
14,0 14,0 615
8,6
26,0 17,6 770
6,8
32,5 16,9 741
5,3
16,5 29,1 1273 7,2
26,0 43,2 1889 10,4 37,5 67,4 2948 19,9 28,5
10
5,6
246
1,0
18,0 12,7 555
7,2
28,5 15,8 691
5,6
34,5 15,1 662
4,3
20,0 26,1 1144 6,0
29,0 38,9 1704 8,7
39,5 60,7 2657 16,5 31,0
15
4,9
215
0,8
22,0 11,3 494
5,8
31,5 14,0 613
4,5
36,5 13,3 583
3,4
24,0 23,2 1014 4,8
31,5 34,7 1517 7,0
41,0 54,0 2363 13,3 33,0
20
4,2
184
0,6
26,0
4,6
34,5 12,2 533
3,5
38,5 11,5 502
2,6
27,5 20,2 883
3,7
34,0 30,3 1328 5,5
43,0 47,2 2066 10,5 36,5
9,9
433
Tw1/Tw2 = 60/40°C
0
5,4
234
1,0
7,5
12,4 540
7,1
18,5 15,4 671
5,5
24,0 14,6 637
4,2
10,0 25,5 1110 5,9
18,5 38,1 1659 8,6
29,0 59,5 2593 16,3 20,5
5
4,7
203
0,8
11,5 11,0 479
5,6
21,0 13,6 592
4,4
26,0 12,8 558
3,3
13,5 22,5 980
4,7
21,0 33,8 1475 6,9
30,5 52,8 2303 13,2 23,5
10
3,9
170
0,6
15,5
9,6
418
4,5
24,0 11,8 512
3,4
28,0 11,0 478
2,5
17,5 19,5 849
3,6
24,0 29,5 1288 5,4
32,5 46,1 2010 10,3 26,0
15
3,1
135
0,4
19,5
8,2
356
3,4
27,0
9,9
431
2,5
30,5
9,1
396
1,8
21,0 16,5 717
2,7
27,0 25,2 1097 4,1
34,0 39,3 1712 7,7
28,5
20
1,9
82
0,2
22,5
6,7
293
2,4
30,0
8,0
349
1,7
32,5
7,2
312
1,2
24,5 13,3 581
1,9
29,5 20,7 902
35,5 32,4 1410 5,5
31,0
2,9
To obtain operating parameters concerning other water temperatures, please contact Sales Office.
V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Tw1 –inlet water temperature
Tw2 –outlet water temperature
Qw – water stream flow in the heat exchanger
Δpw – water pressure drop in the heat exchanger
Accessories
FB 4-SIDE OUTLET GRILLE
Material: powder-painted steel
Weight: 2,8 kg
max. 5 m
max. 12 m
FB CONFUSOR
Material: powder-painted steel
Weight: 3,8 kg
Dedicated for fan heaters
LEO FB 25|45|65
Dedicated for fan heaters
LEO FB 25|45|65
Confusor increases air flow speed. It results in greater range and faster air
distribution to the lower zones of the room.
Outlet grille improves air distribution. It is perfect solution for rooms with low
ceilings, where heaters are installed under the ceiling.
Indexes FB accessories
Name
FB confusor
FB 4-side outlet grille
console FB S
console FB L
Index
10974
10972
10930
10929
10 LEO FB
Air heating and ventilation
Accessories
MIXING CHAMBER
Material: galvanized steel, aluminum, plastic
Dedicated for fan heaters
LEO FB 25|45|65|95
LEO FB + KM L
LEO FB fan heaters with LEO KM L
mixing chamber form a heating
and ventilation unit. It is the
easiest way to create efficient
mechanical ventilation without
additional systems.
LEO FB 25
+ KM L
Heating capacity [kW]
Air flow [m³/h]
Weight [kg]
Colour
Casing
Indexes LEO KM L
Name
KM L
KM 95
Index
11838
10997
LEO FB 45
+ KM L
LEO FB 65
+ KM L
LEO FB 95
+ KM 95
14–24
24–37
29 – 52
47 – 87
1550–3200 1470–3000 1300–2800 2650–6500
31,0–73,7
silver
steel + aluminium + plastic + EPP
Dimensions
LEO FB 95 + KM 95
LEO FB 25|45|65 + KM L
870
1080
650
555
1040
315
870
555
640
600
720
920
145
Installation
min. 1,0 m
installation under the ceiling
2,5–8,0 m
2,5–8,0 m
installation using pins
installation using brackets
min. 1,0 m
(1)
Only for LEO FB 95 + KM 95
Air heating and ventilation
LEO FB 11
Control systems
KM REGULATION
Complete control and protection set for LEO KM L.
Elements of FB + KM L set:
• DRV KM control module,
• dampers actuator,
• 3-way valve with 3-point actuator,
• fresh air temperature sensor,
• ambient air temperature sensor,
• supplied air temperature sensor,
• heating medium temperature sensor.
Basic functions:
• modulated or 3-step fan regulation,
• heat exchanger antifreeze protection,
• room antifreeze protection,
• smooth regulation of supplied air temperature,
• balance, overpressure or underpressure to roof fans,
• possibility of connection to BMS,
• weekly programmer,
• possibility of control up to 31 units in System FLOWAIR by one T-box controller,
• possibility to connect gas detection unit.
LEO KM ventilation
KM regulation
SP 0-10
min.
4×0,5 mm2
min.
2×0,5 mm2
PT-1000
PT-1000
PT-1000
UVO H3.0
(screened)
T-box
SRX3d
min.
2×0,5 mm2
PT-1000
(screened)
type V: min.
5×1,0 mm2
LIYCY min. 4x0,5 mm2
A and B braided wire
pair max. 50 m
min.
2×0,5 mm2
type M: min.
3×1,0 mm2
(screened)
min.
2×0,5 mm2
(screened)
min.
4×1,5 mm2
type M: min.
4×0,5 mm2
FAL-0,75
min.
3×0,5 mm2
DRV KM
min.
4×0,5 mm2
min.
3×1,5 mm2
power supply
~230 V
power supply
~230 V
LIYCY min. 3x0,5 mm
A and B braided wire
pair max. 50 m
2
min.
3×1,5 mm2
UVO H3.0
SP 0-10
PT-1000
PT-1000
PT-1000
SRX3d
max. 31 devices compatible
with FLOWAIR System
PT-1000
FAL-0,75
DRV KM
power supply
~230 V
power supply
~230 V
Indexes LEO KM L control system
Name
T-box
FA L-0, 75
UVO H3. 0
KMFB set
Index
10799
10711
15001
11782
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
12 LEO FB
Ductless ventilation with heat recovery
Roof fans UVO
UVO H is a group of roof fans with horizontal air outlet. They are designed for ventilation of any type of buildings. They are installed on the roof of the building
and their main function is to remove used air from the room.
H3.0
H1.4
Ø 540
460
610
Ø 540
Ø 250
8x Ø 10
8x Ø 9
Ø 160
Ø 274
Ø 274
Technical data
UVO H1.4
UVO H3.0
Max. air flow stream [m /h]
1400
3000
Revs [min-1]
2600
3000
Power supply(1) [V]
230
Y – 3 x 400
Δ – 3 x 230
Max. current consumption [A]
0,7
Y – 1,33
Δ – 2,3
550
3
Max. power consumption [W]
160
IP
44
54
Max. underpressure [Pa]
550
520
Max. air temperature [oC]
40
Max. air contamination [g/m3]
Casing
ABS plastic
Colour
grey
Weight [kg]
Max. acoustic pressure
level [dB(A)]
(1)
60
0,3
8,0
inlet
outlet
20,0
1m
65,7
74,0
5m
54,9
60,0
1m
70,0
80,0
5m
61,0
70,0
Factory motor winding of UVO H3.0 roof fan has Y connecton (for power supply 3x400V)
In case of connection to 3x230V power supply, fan winding must have Δ connection (e.g. in case of use a FAL-0.75 inverter)
Air heating and ventilation
LEO FB 13
Control systems
Fan heater
LEO V
Fan heater
LEO M
Regulacja
TS
Regulacja
HMI
Regulacja
T-box
3-step fan speed regulator with
thermostat
Programmable controller
Intelligent controller with
touch screen
Controlling options
Manual 3-step air flow regulation
Automatic 3-step air flow regulation
Automatic stepless air flow regulation
Modes
Heating / Cooling / Ventilation
Operation in continuous or thermostatic mode
Weekly programmer
BMS
Room antifreeze
Integration with FLOWAIR System
Max. number of connected units
Via controller
Via 1 additional splitter RX
Via 2 additional splitters RX
Via 3 additional splitters RX
LEO FB
10|20|30
LEO FB
25|45|65|95
LEO FB
10|20|30
LEO FB
25|45|65|95
LEO FB
10|20|30|25|45|65|95
7
12
24
36
3
6
12
18
2
12
24
36
1
6
12
18
31
n/a
n/a
n/a
Type of fan
AC – fan with 3-step motor
EC – fan with electronically commutated motor; energysavings up to 50%
14 LEO FB
Ductless ventilation with heat recovery
Control systems
LEO type V fan heaters
TS regulation
SRQ
SRQ
SRQ
max. 7 units
LEO FB 10|20|30 V
min.
3×0,5 mm2
max. 3 units
LEO FB 25|45|65|95 V
TS
min.
5×1,0 mm2
to 1 regulator TS
min.
3×1,0 mm2
power supply
~230 V
LEO type V fan heaters
TS regulation + RX
SRQ
SRQ
max. 12 units
LEO FB 10|20|30 V
min.
3×0,5 mm2
max. 6 units
LEO FB 25|45|65|95 V
min.
5×0,5 mm2
TS
min.
5×1,0 mm2
to 1 RX splitter
RX
min.
3×1,5 mm2
min.
5×0,5 mm2
power supply
~230 V
SRQ
SRQ
max. 3
RX splitters
max. 12 units
LEO FB 10|20|30 V
max. 6 units
LEO FB 25|45|65|95 V
RX
to 1 RX splitter
power supply
~230 V
LEO type V fan heaters
HMI regulation
SRQ
NTC
(option)
min.
2×0,5 mm2
HMI
min.
3×0,5 mm2
min.
5×1,0 mm2
min.
3×1,0 mm2
max. 2 units
LEO FB 10|20|30 V
max. 1 unit
LEO FB 25|45|65|95 V
to 1 controller HMI
power supply
~230 V
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
Air heating and ventilation
LEO FB 15
Control systems
LEO type V fan heaters
HMI regulation + RX
SRQ
SRQ
NTC
(option)
min.
5×0,5 mm2
max. 6 units
LEO FB 25|45|65|95 V
min.
5×1,0 mm2
min.
6×0,5 mm2
HMI
max. 12 units
LEO FB 10|20|30 V
min.
3×0,5 mm2
min.
2×0,5 mm2
to 1 RX splitter
RX
min.
3×1,5 mm2
power supply
~230 V
SRQ
SRQ
max. 3
RX splitters
max. 12 units
LEO FB 10|20|30 V
max. 6 units
LEO FB 25|45|65|95 V
RX
to 1 RX splitter
power supply
~230 V
LEO type M fan heaters
T-box regulation
min.
2×0,5 mm2
(screened)
SRQ
SRQ
PT-1000
(option)
PT-1000
(option)
min.
3×0,5 mm2
T-box
max. 31 devices compatible
with FLOWAIR System
LIYCY min. 3x0,5 mm
A and B braided wire
pair max. 50 m
2
min.
3×1,0 mm2
LIYCY min. 4x0,5 mm2
A and B braided wire
pair max. 50 m
power supply
~230 V
power supply
~230 V
Indexes LEO FB V control system
Name
T- box
HM I
TS
RX
Index
10799
11775
10996
11779
SRQ2d-½ SRQ2d-¾ SRQ3d-½ SRQ3d-¾
10803
10788
10804
10805
N TC
PT- 1 0 0 0
10791
10546
Indexes LEO FB M control system
Name
T- box
Index
10799
SRQ2d-½ SRQ2d-¾ SRQ3d-½ SRQ3d-¾ PT-1000
10803
10788
10804
10805
10546
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
16 LEO FB
Air heating and ventilation
Destratificator LEO D
Destratificator LEO D
Air flow [m3/h]
Weight [kg]
Colour
Casing
3100–5400
13,9
grey
EPP (expanded polypropylene)
Application:
High industrial and public buildings, like industrial halls, warehouses, supermarkets,
exhibition halls.
Available types of units:
LEO D 2
Destratificator without additional regulation systems with possibility of 3-step air flow
regulation.
Indexes LEO D
Name
D 2
DT 2
Index
10062
10063
LEO DT 2
Destratificator with thermostat, which turns on the unit automatically, when ambient
temperature rises above set temperature.
Additional description:
The main function of destratificator is to prevent accumulation of warm air in upper zones
of the room. The fan intakes warm air and forces its flow to the zone occupied by the
people. This solution reduces heat losses through the ceiling and results in faster heating
of the building.
Special attributes
FAN
EPP CASING
AIR NOZZLE
AIR BLADES
LEO D are equipped with 3-step
fan. It is the simplest and an effective way to control operation
of the destratificator.
Mechanical strength, resistance
to dirt, low weight and aesthetic
look – everything thanks to EPP
material (expanded polypropylene).
Fan is placed in specially designed nozzle. Its profile reduces
air flow noise and and increases
unit’s efficiency.
Air outlet is equipped with air
deflectors for easy air stream direction and split of the air flow.
Dimensions
350
LEO D
580
Air heating and ventilation
650
LEO D 17
Technical data
Max. air flow [m3/h]
Power supply [V/Hz]
Max. current consumption [A]
Max. power consumption [W]
IP
Max. acoustic pressure level(1) [dB(A)]
Max. operating temperature [oC]
Weight of unit [kg]
(1)
LEO D 2 | DT 2
5400
230/50
1,4
320
54
55
60
13,9
Acoustic pressure level at the distance of 5 m from the unit, in the room of medium capability of sound absorption and 1500 m3 of cubature
Hmin.
Installation
14m
Hmax.
11m
3rd step
2nd step
1st step
8m
Corner holders
Destratificator is equipped with holders, which make the installation and
leveling of the unit under the ceiling
much easier. In case of installation
under the ceiling which transmit
vibrations it is recommended to use
vibro-isolators.
Hmax – maximum mounting height for air blades
installed vertically
Hmin – 1/3 heigh of hall, minimum 1m
18 LEO D
Air heating and ventilation
Control systems
LEO D 2 destratificator
T-box regulation
min.
5×1,0 mm2
max. 31 devices compatible
with FLOWAIR System
PT-1000
(in set)
T-box
LIYCY min. 4x0,5 mm2
A and B braided wire
pair max. 50 m
DRV D
DRV D
PT-1000
(in set)
PT-1000
(in set)
min.
3×1,0 mm2
power supply
~230 V
min.
2×0,5 mm2
(screened)
PT-1000
(option)
LIYCY min. 3x0,5 mm2
A and B braided wire
pair max. 50 m
power supply
~230 V
PT-1000
(option)
LEO DT 2 destratificator
ON/OFF regulation
min.
3×1,0 mm2
power supply
~230 V
Indexes LEO D 2 control systems
Name
T-box
DRV D
PT-1000
Index
10799
11784
10546
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
Air heating and ventilation
LEO D 19
Fan heaters LEO FS
Fan heaters LEO FS
Heating capacity [kW]
Air flow [m3/h]
Weight [kg]
Colour
Casing
5–19
23 0– 1750
13,8– 16,8
grey
antistatic ABS
Application:
Small and medium cubature buildings, representative buildings, like restaurants, pubs,
stores etc.
Available types of units:
Indexes LEO FS V
Indexes LEO FS M
LEO FS V
Name
F S 19V
Name
FS 19M
Fan heater with AC fan, with possibility of 3-step air flow regulation.
Index
10975
Index
10021
LEO FS M
Heater with energy-efficient fan with EC motor, controlled by external 0-10V signal,
enabling stepless regulation of fan speed in range of 0-100%.
Special attributes
3-STEP FAN
EC FAN
CASING
EASY INSTALLATION
LEO FS V fan heaters are equipped
with 3-step fan. It is the simplest
and effective way to control operation of the heater.
Use of energy-efficient fan with
EC motor in LEO FS M fan heaters
reduces energy costs even by 50%.
Is made of durable plastic – ABS.
It fully covers all of the water and
electrical connections, what makes the unit very aesthetic.
Light construction and integrated
installation console ensure easy
and quick installation of the unit.
There is no need to use any additional brackets.
Dimensions
LEO FS
20 LEO FS
480
380
640
600
Air heating and ventilation
Technical data
FS V
Max. air flow [m3/h]
Power supply [V/Hz]
Max. current consumption [A]
Max. power consumption [W]
IP
Max. acoustic pressure level(1) [dB(A)]
Max. air stream range(2) [m]
Max. heating water temperature [oC]
Max. operating pressure [MPa]
Weight of unit [kg]
Weight of unit filled with water [kg]
(1)
(2)
FS M
1750
230/50
0,5
110
0,25
57,5
54
47
45
12,0
95
1,6
14,6
15,8
13,8
15,0
Acoustic pressure level at the distance of 5 m from the unit, in the room of medium capability of sound absorption and 1500 m3 of cubature
Range of horizontal isothermal air stream, at 0,5 m/s velocity limit
Installation
min. 0,4 m
max. 3,0 m
Installation console
Thanks to integrated instalation console there is no need
to use any additional brackets to install the unit.
Heating capacities
LEO FS
Tw1/Tw2 = 90/70°C
Tw1/Tw2 = 80/60°C
Tw1/Tw2 = 70/50°C
Tw1/Tw2 = 60/40°C
Tw1/Tw2 = 50/40°C
Tp1
PT
Qw
∆pw
Tp2
PT
Qw
∆pw
Tp2
PT
Qw
∆pw
Tp2
PT
Qw
∆pw
Tp2
PT
Qw
∆pw
Tp2
°C
kW
l/h
kPa
°C
kW
l/h
kPa
°C
kW
l/h
kPa
°C
kW
l/h
kPa
°C
kW
l/h
kPa
°C
V = 1750 m3/h
0
19,0
838
4,8
32,0
16,2
711
3,7
27,5
13,4
584
2,7
22,5
10,4
454
1,8
17,5
10,4
907
6,3
17,5
5
17,8
784
4,3
35,0
14,9
657
3,2
30,0
12,1
529
2,3
25,5
9,1
397
1,4
20,5
9,2
796
5,0
20,5
10
16,5
729
3,8
38,0
13,7
601
2,7
33,0
10,8
472
1,8
28,0
7,8
339
1,1
23,0
7,9
684
3,8
23,0
15
15,2
673
3,3
40,5
12,4
545
2,3
36,0
9,5
415
1,5
31,0
6,4
278
0,8
25,5
6,6
570
2,7
26,0
20
14,0
616
2,8
43,5
11,1
488
1,9
38,5
8,2
357
1,1
33,5
4,9
211
0,5
28,0
5,2
455
1,8
29,0
To obtain operating parameters concerning other water temperatures, please contact Sales Office.
V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Air heating and ventilation
Tw1 –inlet water temperature
Tw2 –outlet water temperature
Qw – water stream flow in the heat exchanger
Δpw – water pressure drop in the heat exchanger
LEO FS 21
Control systems
Fan heater
LEO V
Fan heater
LEO M
TS
regulation
HMI
regulation
T-box
regulation
3-step fan speed regulator with
thermostat
Programmable controller
Intelligent controller with
touch screen
7
12
24
36
2
12
24
36
31
n/a
n/a
n/a
Controlling options
Manual 3-step air flow regulation
Automatic 3-step air flow regulation
Automatic stepless air flow regulation
Modes
Heating / Cooling / Ventilation
Operation in continuous or thermostatic mode
Weekly programmer
BMS
Room antifreeze
Integration with FLOWAIR System
Max. number of connected units
Via controller
Via 1 additional splitter RX
Via 2 additional splitters RX
Via 3 additional splitters RX
Type of fan
AC – fan with 3-step motor
EC – fan with electronically commutated motor; energysavings up to 50%
22 LEO FS
Air heating and ventilation
Control systems
LEO type V fan heaters
TS regulation
SRQ
SRQ
SRQ
min.
3×0,5 mm2
TS
max. 7 units
LEO FS V
to 1 regulator TS
min.
5×1,0 mm2
min.
3×1,0 mm2
power supply
~230 V
LEO type V fan heaters
TS regulation + RX
SRQ
SRQ
min.
3×0,5 mm2
max. 12 units
LEO FS V
to 1 RX splitter
min.
5×0,5 mm2
TS
min.
5×1,0 mm2
RX
min.
3×1,5 mm2
min.
5×0,5 mm2
power supply
~230 V
SRQ
SRQ
max. 3
RX splitters
max. 12 units
LEO FS V
to 1 RX splitter
RX
power supply
~230 V
LEO type V fan heaters
HMI regulation
SRQ
NTC
(option)
min.
2×0,5 mm2
HMI
min.
3×0,5 mm2
min.
5×1,0 mm2
max. 2 units
LEO FS V
to 1 controller HMI
min.
3×1,0 mm2
power supply
~230 V
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
Air heating and ventilation
LEO FS 23
Control systems
LEO type V fan heaters
HMI regulation + RX
SRQ
SRQ
NTC
(option)
min.
3×0,5 mm2
min.
2×0,5 mm2
min.
5×0,5 mm2
min.
5×1,0 mm2
min.
6×0,5 mm2
HMI
max. 12 units
LEO FS V
to 1 RX splitter
RX
min.
3×1,0 mm2
power supply
~230 V
SRQ
SRQ
max. 3
RX splitters
max. 12 units
LEO FS V
to 1 RX splitter
RX
power supply
~230 V
LEO type M fan heaters
T-box regulation
min.
2×0,5 mm2
(screened)
SRQ
SRQ
PT-1000
(option)
PT-1000
(option)
min.
3×0,5 mm2
T-box
max. 31 devices compatible
with FLOWAIR System
LIYCY min. 3x0,5 mm
A and B braided wire
pair max. 50 m
2
min.
3×1,0 mm2
LIYCY min. 4x0,5 mm2
A and B braided wire
pair max. 50 m
power supply
~230 V
power supply
~230 V
Indexes LEO FS V control systems
Name
T-box
HM I
TS
RX
Index
10799
11775
10996
11779
SRQ2d-½ SRQ3d-½
10803
DR V M
PT-1000
11783
10546
10804
NTC
PT- 1 0 0 0
10791
10546
Indexes LEO FS M control system
Name
T-box
Index
10799
SRQ2d-½ SRQ3d-½
10803
10804
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
24 LEO FS
Air heating and ventilation
Fan heaters LEO INOX
Fan heaters LEO INOX
Heating capacity [kW]
Air flow [m3/h]
Weight [kg]
Colour
Casing
10–65
900–4400
16,1–25,4
–
stainless steel
Application:
Big cubature buildings, with high humidity, like food industry buildings, gastronomy
buildings, greenhouses etc.
Available types of units:
LEO INOX V
Fan heater with AC fan, with possibility of 3-step air flow regulation.
LEO INOX M
Indexes LEO INOX V
Name
I N OX 25V
I N OX 45V
INOX 65V
Index
10987
1098 8
10989
Heater with energy-efficient fan with EC motor, controlled by external 0-10V signal,
enabling stepless regulation of fan speed in range of 0-100%.
Indexes LEO INOX M
Name
I N OX 25M
I N OX 45M
INOX 65M
Index
10070
1007 2
10073
Special attributes
3-STEP FAN
EC FAN
CASING
AIR OUTLET
LEO INOX V fan heaters are equipped with 3-step fan. It is the simplest and effective way to control
operation of the heater.
Use of energy-efficient fan with EC
motor in LEO INOX M fan heaters
allows reduction of energy costs
even by 50%.
Attractive and modern casing of
the unit is made of stainless steel
(AISI 316L), which ensures resistance to corrosion.
Air outlet is equipped with stainless steel air deflectors for easy air
stream direction to the desired
area.
Dimensions
LEO INOX 25|45|65
630
440
600
640
370
Air heating and ventilation
LEO INOX 25
Technical data
INOX 25V
Max. air flow [m3/h]
Power supply [V/Hz]
Max. current consumption [A]
Max. power consumption [W]
IP
Max. acoustic pressure level(1) [dB(A)]
Max. air stream range(2) [m]
Max. heating water temperature [oC]
Max. operating pressure [MPa]
Weight of unit [kg]
Weight of unit filled with water [kg]
(1)
(2)
INOX 25M
INOX 45V
4400
1,4
320
54
0,7
170
1,4
320
51
54
26,0
19,4
20,4
16,1
17,1
20,8
22,8
INOX 45M
4100
230/50
0,7
170
54
51
24,0
130
1,6
17,5
19,5
INOX 65V
INOX 65M
3900
1,4
320
0,7
170
54
51
22,0
22,7
25,4
19,4
22,1
Acoustic pressure level at the distance of 5 m from the unit, in the room of medium capability of sound absorption and 1500 m3 of cubature
Range of horizontal isothermal air stream, at 0,5 m/s velocity limit
Installation
installation under the ceiling
min. 0,3 m
60°
45°
90°
Corner holders as standard
Easy installation and leveling of the heater.
vertical installation using the console
90°
2,5–5,0 m
60°
2,5–10,0 m
45°
170°
Rotary console
Enables easy installation of the heater perpendicularly
or at various angles to the wall and 170° rotation.
Indexes
Name
co n so l e I N OX
Index
10990
26 LEO INOX
Air heating and ventilation
Heating capacities
Tp1
°C
Tw1/Tw2 = 90/70°C
PT
Qw
∆pw
kW
l/h
kPa
Tp2
°C
PT
kW
0
5
10
15
20
26,7
25,0
23,2
21,4
19,7
1179
1101
1024
946
868
11,6
10,2
8,9
7,7
6,6
18,0
22,0
25,0
29,5
33,0
22,7
21,0
19,2
17,4
15,6
0
5
10
15
20
45,0
42,1
39,2
36,3
33,4
1986
1958
1730
1603
1475
15,2
13,4
11,8
10,3
8,8
32,5
35,5
38,0
41,0
43,5
38,5
35,6
32,7
29,8
26,8
0
5
10
15
20
65,5
61,4
57,3
53,1
48,9
2892
2712
2529
2344
2159
21,3
18,9
16,7
14,5
12,5
50,0
51,5
53,0
55,0
56,5
56,5
52,3
48,2
44,0
39,7
Tw1/Tw2 = 80/60°C
Qw
∆pw
Tp2
l/h
kPa
°C
LEO INOX 25
V = 4400 m3/h
999
8,8
15,5
921
7,6
19,0
843
6,5
23,0
765
5,4
26,5
686
4,5
30,5
LEO INOX 45
V = 4100 m3/h
1693
11,7
27,5
1565
10,2
30,5
1437
8,7
33,5
1308
7,3
36,0
1179
6,1
39,0
LEO INOX 65
V = 3900 m3/h
2481
16,6
43,0
2300
14,4
44,5
2116
12,4
46,5
1931
10,5
48,0
1744
8,8
50,0
PT
kW
Tw1/Tw2 = 70/50°C
Qw
∆pw
l/h
kPa
Tp2
°C
PT
kW
Tw1/Tw2 = 60/40°C
Qw
∆pw
l/h
kPa
Tp2
°C
18,7
16,9
15,1
13,3
11,5
819
741
662
583
502
6,3
5,3
4,3
3,4
2,6
12,5
16,5
20,0
24,0
27,5
14,6
12,8
11,0
9,1
7,2
637
558
478
396
312
4,2
3,3
2,5
1,8
1,2
10,0
13,5
17,5
21,0
24,5
32,0
29,1
26,1
23,2
20,2
1402
1273
1144
1014
883
8,6
7,2
6,0
4,8
3,7
23,0
26,0
29,0
31,5
34,0
25,5
22,5
19,5
16,5
13,3
1110
980
849
717
581
5,9
4,7
3,6
2,7
1,9
18,5
21,0
24,0
27,0
29,5
47,3
43,2
38,9
34,7
30,3
2071
1889
1704
1517
1328
12,3
10,4
8,7
7,0
5,5
36,0
37,5
39,5
41,0
43,0
38,1
33,8
29,5
25,2
20,7
1659
1475
1288
1097
902
8,6
6,9
5,4
4,1
2,9
29,0
30,5
32,5
34,0
35,5
To obtain operating parameters concerning other water temperatures, please contact Sales Office.
V – air flow
PT – heating capacity
Tp1– inlet air temperature
Tp2 –outlet air temperature
Tw1 –inlet water temperature
Tw2 –outlet water temperature
Qw – water stream flow in the heat exchanger
Δpw – water pressure drop in the heat exchanger
Control systems
Fan heater
LEO V
Fan heater
LEO M
TS
regulation
HMI
regulation
T-box
regulation
3-step fan speed regulator with
thermostat
Programmable controller
Intelligent controller with
touch screen
3
6
12
18
1
6
12
18
31
n/a
n/a
n/a
Controlling options
Manual 3-step air flow regulation
Automatic 3-step air flow regulation
Automatic stepless air flow regulation
Modes
Heating / Cooling / Ventilation
Operation in continuous or thermostatic mode
Weekly programmer
BMS
Room antifreeze
Integration with FLOWAIR System
Max. number of connected units
Via controller
Via 1 additional splitter RX
Via 2 additional splitters RX
Via 3 additional splitters RX
Type of fan
AC – fan with 3-step motor
EC – fan with electronically commutated motor; energysavings up to 50%
Air heating and ventilation
LEO INOX 27
Control systems
LEO type V fan heaters
TS regulation
SRQ
SRQ
SRQ
min.
3×0,5 mm2
TS
max. 3 units
LEO INOX V
to 1 regulator TS
min.
5×1,0 mm2
min.
3×1,0 mm2
power supply
~230 V
LEO type V fan heaters
TS regulation + RX
SRQ
SRQ
min.
3×0,5 mm2
max. 6 units
LEO INOX V
to 1 RX splitter
min.
5×0,5 mm2
TS
min.
5×1,0 mm2
RX
min.
3×1,5 mm2
min.
5×0,5 mm2
power supply
~230 V
SRQ
max. 3
RX splitters
SRQ
max. 6 units
LEO INOX V
to 1 RX splitter
RX
power supply
~230 V
LEO type V fan heaters
HMI regulation
SRQ
NTC
(option)
min.
2×0,5 mm2
min.
3×0,5 mm2
HMI
min.
5×1,0 mm2
min.
3×1,0 mm2
power supply
~230 V
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
28 LEO INOX
Air heating and ventilation
Control systems
LEO type V fan heaters
HMI regulation + RX
SRQ
SRQ
NTC
(option)
min.
3×0,5 mm2
min.
2×0,5 mm2
min.
6×0,5 mm2
HMI
min.
5×0,5 mm2
max. 6 units
LEO INOX V
to 1 RX splitter
min.
5×1,0 mm2
RX
min.
3×1,5 mm2
power supply
~230 V
SRQ
SRQ
max. 3
RX splitters
max. 6 units
LEO INOX V
to 1 RX splitter
RX
power supply
~230 V
LEO type M fan heaters
T-box regulation
min.
2×0,5 mm2
(screened)
SRQ
SRQ
PT-1000
(option)
PT-1000
(option)
min.
3×0,5 mm2
T-box
max. 31 devices compatible
with FLOWAIR System
LIYCY min. 3x0,5 mm2
A and B braided wire
pair max. 50 m
min.
3×1,0 mm2
LIYCY min. 4x0,5 mm2
A and B braided wire
pair max. 50 m
power supply
~230 V
power supply
~230 V
Indexes LEO INOX V control systems
Name
T-box
HM I
TS
RX
SRQ2d-¾
SRQ3d-¾
N TC
PT- 1 0 0 0
Index
10799
11775
10996
11779
10788
10805
10791
10546
Indexes LEO INOX M control system
Name
T-box
SRQ2d-¾
SRQ3d-¾
PT-1000
Index
10799
10788
10805
10546
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
Air heating and ventilation
LEO INOX 29
Fan heaters LEO EX
Fan heaters LEO EX
Heating capacity [kW]
Air flow [m3/h]
Weight [kg]
Colour
Casing
26–45
3800–4300
33,1–34,5
grey
powder-painted steel
Application:
Buildings with special safety requirements, like heavy industry halls, welding plants etc.
Additional description:
Fan heater equipped with anti-explosion fan and may be installed in Z-2 explosion-risk
zones, in rooms at risk of explosion of gases, liquids and their fumes from IIB group of
explosiveness and T3 temperature class.
Indexes LEO EX
Name
EX 25
E X 45
Index
10040
10041
Special attributes
CERTIFICATES IN
ACCORDANCE TO DIRECTIVES
AIR NOZZLE
AIR OUTLET
INSTALLATION
All components installed in the
hazardous area are approved in
accordance with ATEX directive,
allowing for work in 2G zone.
Specially designed profile made of
plastic reduces air flow noise.
When installing the heater horizontally under the ceiling, there
is the possibility to blow the air
in two directions effectively distributing the warm air on larger
surface of the room.
Possibility of installation on
the wall, as well as under the
ceiling.
Dimensions
LEO EX
345
540
630
655
30 LEO EX
Air heating and ventilation
Technical data
LEO EX 25
4300
Max. air flow [m3/h]
Power supply [V/Hz]
Max. current consumption [A]
Max. power consumption [W]
IP
Max. acoustic pressure level(1) [dB(A)]
Max. air stream range(2) [m]
Max. heating water temperature [oC]
Max. operating pressure [MPa]
Weight of unit [kg]
Weight of unit filled with water [kg]
(1)
(2)
LEO EX 45
3800
3x400/50
0,51
290
44
51
24,0
22,0
130
1,6
33,1
34,2
34,5
36.6
Acoustic pressure level at the distance of 5 m from the unit, in the room of medium capability of sound absorption and 1500 m3 of cubature
Range of horizontal isothermal air stream, at 0,5 m/s velocity limit
Installation
installation under the ceiling
min. 0,8 m
FX brackets
Enable easy and quick installation of the unit on the wall
or under the ceiling.
2,5–8 m
2,5–10 m
min. 0,3 m
vertical installation using the console
min. 0,3 m
Indexes
Name
bra ckets
Index
10563
Air heating and ventilation
LEO EX 31
Heating capacities
Tw1/Tw2 = 90/70°C
Tw1/Tw2 = 80/60°C
Tw1/Tw2 = 70/50°C
Tw1/Tw2 = 60/40°C
Tw1/Tw2 = 50/40°C
Tp1
PT
Qw
∆pw
Tp2
PT
Qw
∆pw
Tp2
PT
Qw
∆pw
Tp2
PT
Qw
∆pw
Tp2
PT
Qw
∆pw
Tp2
°C
kW
l/h
kPa
°C
kW
l/h
kPa
°C
kW
l/h
kPa
°C
kW
l/h
kPa
°C
kW
l/h
kPa
°C
LEO EX 25
V = 4300 m3/h
0
25,5
1090
7,6
17,0
21,7
946
5,9
15,0
18,0
802
4,4
12,0
14,7
642
4,9
10,0
14,1
1229
14,9
11,0
5
23,7
1018
6,7
21,0
20,0
5874
5,1
19,0
16,3
694
3,7
16,0
12,8
558
3,8
13,0
12,4
1080
11,8
13,0
10
22,0
946
5,9
25,0
18,2
802
4,4
23,0
14,5
622
3,0
20,0
10,9
475
2,8
17,0
10,7
930
9,0
18,0
15
20,2
874
5,1
29,0
16,5
730
3,7
26,0
12,8
550
2,4
24,0
9,0
392
2,0
21,0
9,0
779
6,6
21,0
20
18,4
805
4,3
33,0
14,8
658
3,0
30,0
11,1
478
1,9
28,0
7,0
308
1,3
25,0
7,2
626
4,4
25,0
LEO EX 45
V = 3800 m3/h
0
44,9
1882
12,5
35,0
37,2
1584
9,8
29,0
31,2
1340
7,4
24,0
26,8
1167
7,3
20,0
24,9
2167
21,4
20,0
5
41,0
1738
11,0
37,0
34,4
1476
8,4
32,0
28,4
1225
6,3
27,0
23,4
1020
5,7
22,0
22,0
1911
17,1
22,0
10
37,3
1630
9,7
39,0
31,5
1368
5,2
35,0
25,5
1080
5,2
30,0
20,1
876
4,4
25,0
19,0
1654
13,2
25,0
15
34,6
1476
8,3
42,0
28,6
1224
6,1
37,0
22,6
975
4,2
33,0
16,8
732
3,2
28,0
16,0
1395
9,7
28,0
20
31,8
1368
7,1
45,0
25,7
1116
5,0
40,0
19,7
865
3,3
35,0
13,5
589
2,2
31,0
13,0
1134
6,7
30,0
To obtain operating parameters concerning other water temperatures, please contact Sales Office.
V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Tw1 –inlet water temperature
Tw2 –outlet water temperature
Qw – water stream flow in the heat exchanger
Δpw – water pressure drop in the heat exchanger
Control systems
Control system is selected individually depending on the degree of explosion risk in given building. Control system elements should also be in anti-explosion
version and should have at least the same anti-explosion degree like the fan. Fan motor requires to use special external protection systems, i.e. U-EK 230E or
similar.
32 LEO EX
Air heating and ventilation
Electric heaters LEO EL
Electric heaters LEO EL 23
Heating capacity(1) [kW]
Air flow(1) [m3/h]
Weight [kg]
Colour
Casing
(1)
9 or 16 / 23
3400 / 4200
23,5
silver-graphite
steel
Parameters for 1st step of operation
Application:
Big cubature buildings, like industrial halls, warehouses, department stores, as well as
smaller cubature buildings, like workshops, garages.
Additional description:
LEO EL 23 electric heaters are designed to operate indoors. They can be applied where
there is no other heat sources, like gas installation or hot water.
Indexes LEO EL
Name
E L 23
Index
10783
Special attributes
II
I
HEATING ELEMENTS
CONTROL SYSTEM
THREE MODES
SIGNAL LAMPS
PTC heating elements adapt their
temperature to the air flow. Their
construction ensures maximum
use of the heating capacity on
each step of heating.
Heater is equipped with a complete power and protection system. It also have protection against
overheating.
As a standard heater is equipped with room thermostat with
mode switch.
Signal lamps indicate the current status of the heater.
Dimensions
LEO EL 23
725
630
370
600
640
Air heating and ventilation
LEO EL 33
Technical data
LEO EL 23
Max. air flow [m3/h]
Power supply [V/Hz]
Current consumption [A]
Max. power consumption[kW]
IP
Max. acoustic pressure level(1) [dB(A)]
Max. air stream range(2) [m]
Max. operating temperature [°C]
Weight of unit [kg]
(1)
(2)
I step
II step
3400
4200
3×400/50
13/23
9/16
34
23
20
51
18
23
40
23,5
Acoustic pressure level at the distance of 5 m from the unit, in the room of medium capability of sound absorption and 1500 m3 of cubature
Range of horizontal isothermal air stream, at 0,5 m/s velocity limit
Installation
Only horizontal installation allowed!
> 0,3 m
2,5–8,0 m
170°
Rotary console
Enables installation of the heater vertically on
the wall. It also enables rotation of the unit
around connection points with the console.
Control system
Electric heater LEO EL 23
TS regulation
Unit is equipped with a complete
power, control and protection
system.
TS
power supply
~3x400 V
Indexes LEO EL 23 control system
Fan and heaters have thermal protections, which prevent damage of
the unit in case of too high temperature.
As a standard heater is equipped
with room thermostat to change
operating mode and set the desired
temperature.
Available operating modes:
• SUMMER – fan operation only,
without heating, to ensure air circulation in the room,
• I step of heating – two heating capacities available, 9 or 16 kW,
• II step of heating – maximum heating capacity, 23 kW.
Indexes
Name
TS
Name
console
Index
10996
Index
10560
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
34 LEO EL
Air heating and ventilation
Accessories
MIXING CHAMBER
Material: galvanized steel, aluminum, plastic
LEO EL 23 electric heater with
LEO KM L mixing chamber make
a heating and ventilation unit.
It is the easiest way to create
efficient mechanical ventilation
without additional systems.
Heating capacity [kW]
Current consumption [A]
Air flow [m3/h]
Weight of unit [kg]
Indexes LEO KM L
Name
KM L
Index
11838
LEO EL 23 + KM L
Dimensions
LEO EL 23 + KM L
I step
II step
8,3/15,9
22,4
12/19
23
3200
43,0
Installation
Only horizontal installation allowed!
LEO EL 23 + KM L
860
640
555
2,5–8,0 m
555
870
315
145
installation using pins
installation using brackets
720
Control system
Electric heater LEO EL 23 + KM L
Regulation
min.
3×0,5 mm2
NPCT-10
min.
3×0,5 mm2
min.
5×6,0 mm2
min.
5×0,75 mm2
SP 0-10V
control
board
min.
3×0,5 mm2
min.
3×1,5 mm2
TS
power supply
3 x 400V
power supply
~ 230V
Indexes LEO EL 23 + KM L
Name
Regulation
Index
10790
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
Air heating and ventilation
LEO EL 35
Fan heaters LEO AGRO
Fan heaters LEO AGRO
AGRO
16–43
1900–3700
21,8–23,9
Heating capacity [kW]
Air flow [m3/h]
Weight [kg]
Colour
Casing
AGRO SP
20–56
3300–4600
27,3–31,0
grey
powder-painted steel
plastic
Application:
Medium and big cubature buildings with considerable pollution of the air with solid
particles, high humidity or corrosive environment, like agricultural buildings, greenhouses,
piggeries.
Available types of units:
LEO AGRO
Heater with epoxidized heat exchanger in casing made of galvanized steel protected by
anti-corrosive coating.
Indexes LEO AGRO
Name
AGR O
Index
10936
LEO AGRO SP
Heater with epoxidized heat exchanger and long air stream range in casing made of plastic.
Indexes LEO AGRO SP
Name
AGR O S P
Index
10126
Special attributes
EPOXIDIZED HEAT
EXCHANGER
HIGHLY-EFFICIENT FAN
EASY CLEANING
HINGED CASING
Three-row heat exchanger with
40% thicker fins and increased
spacing between them comparing to standard fan heaters, protected by special ani-corrosion
coating which improves the reliability of the unit.
Waterproof and dustproof fan with
IP66 protection and compression
ratio allows the removal of dust
and dirt from the heat exchanger.
Easily removable drip tray with
drain plug allows simple discharge of contaminated water
after cleaning operation.
Quick access to the unit’s interior
thanks to buckles, which fasten
the heat exchanger with confusor. The design of the unit makes
the maintenance and service
operations faster.
Dimensions
LEO AGRO SP
LEO AGRO
630
36 LEO AGRO
600
612
706
700
510
440
630
670
1080
Air heating and ventilation
Technical data
AGRO
3700
Max. air flow [m3/h]
Power supply [V/Hz]
Max. current consumption [A]
Max. power consumption [W]
IP
Max. acoustic pressure level(1) [dB(A)]
Max. air steam range(2) [m]
Max. heating water temperature [oC]
Max. operating pressure [MPa]
Weight of unit [kg]
Weight of unit filled with water [kg]
(1)
(2)
AGRO SP
4600
230/50
1,8
350
2,5
360
66
51
22
130
62
28
95
1,6
21,8
23,9
27,3
31,0
Acoustic pressure level at the distance of 5 m from the unit, in the room of medium capability of sound absorption and 1500 m3 of cubature
Range of horizontal isothermal air stream, at 0,5 m/s velocity limit
Installation
installation under the ceiling(1)
vertical installation using the console
170o
1,5–3,0 m
0,75–1,5 m
1,5–3,0 m
(1)
vertical installation using the brackets
min. 0,3 m
170o
Installation under the ceiling of LEO AGRO SP with 4-side air outlet
170°
Rotary console
LEO AGRO / AGRO SP
Installation brackets
LEO AGRO SP
Rotary console enables 170° rotation ensuring easy direction of the air stream and easy
access to the unit from each side.
Enable easy and quick installation of the
unit. They also ensure optimum air flow
around the unit.
Indexes
Name
brackets FX
console AGRO
console AGRO SP
Index
10563
10971
11774
Air heating and ventilation
LEO AGRO 37
Heating capacities
Tw1/Tw2 = 90/70°C
Tw1/Tw2 = 80/60°C
Tw1/Tw2 = 70/50°C
Tw1/Tw2 = 60/40°C
Tw1/Tw2 = 50/40°C
Tp1
PT
Qw
∆pw
Tp2
PT
Qw
∆pw
Tp2
PT
Qw
∆pw
Tp2
PT
Qw
∆pw
Tp2
PT
Qw
∆pw
Tp2
°C
kW
l/h
kPa
°C
kW
l/h
kPa
°C
kW
l/h
kPa
°C
kW
l/h
kPa
°C
kW
l/h
kPa
°C
LEO AGRO
V = 3700 m3/h
0
43,0
1890
20,0
32,5
37,2
1630
16,0
28,0
31,3
1370
13,0
23,5
25,4
1110
11,0
19,0
23,8
2070
26,0
18,0
5
39,7
1750
17,0
35,5
34,0
1490
15,0
31,0
28,2
1230
11,0
26,5
22,4
980
9,0
22,0
20,8
1810
21,0
21,0
10
36,6
1610
15,0
38,5
30,9
1360
13,0
34,0
25,1
1100
10,0
29,5
19,4
840
7,0
25,0
17,8
1550
18,0
24,0
15
33,5
1470
15,0
41,5
27,8
1220
11,0
37,0
22,2
970
8,0
32,5
16,4
720
7,0
28,0
15,0
1300
13,0
27,0
20
30,4
1340
12,0
44,5
24,9
1090
10,0
40,0
19,2
840
6,0
35,5
13,5
590
5,0
31,0
12,1
1050
10,0
30,0
25
27,5
1210
10,0
47,5
21,9
960
8,0
43,0
16,3
710
6,0
38,5
10,7
460
5,0
34,0
9,3
810
6,0
33,0
30
24,5
1080
10,0
50,5
19,1
840
6,0
46,0
13,5
590
5,0
41,5
7,8
340
3,0
36,5
6,6
570
4,0
35,5
35
21,7
950
8,0
53,5
16,2
710
6,0
49,0
10,7
470
5,0
44,0
4,8
210
3,0
39,0
3,8
330
3,0
38,0
LEO AGRO SP
V = 4600 m3/h
0
56,2
2480
21,0
34,0
48,6
2140
16,0
29,5
41,0
1800
12,0
25,0
33,4
1450
10,0
20,5
31,2
2710
26,0
19,0
5
52,0
2290
18,0
37,0
44,5
1950
14,0
32,5
36,9
1620
10,0
28,0
29,4
1280
8,0
23,0
27,2
2370
21,0
22,0
10
47,8
2110
16,0
40,0
40,4
1780
12,0
35,5
33,0
1440
10,0
31,0
25,5
1110
8,0
26,0
23,4
2030
16,0
24,5
15
43,8
1930
13,0
43,0
36,4
1600
10,0
38,5
29,1
1270
8,0
33,5
21,6
940
6,0
29,0
19,6
1710
12,0
27,5
20
39,8
1750
11,0
46,0
32,6
1430
10,0
41,0
25,3
1110
8,0
36,5
17,9
780
4,0
31,5
15,9
1380
10,0
30,5
25
35,9
1580
9,0
49,0
28,7
1260
8,0
44,0
21,5
940
6,0
39,5
14,1
610
4,0
34,5
12,3
1070
7,0
33,0
30
32,1
1420
9,0
51,5
25,0
1100
7,0
47,0
17,8
780
4,0
42,0
10,3
450
4,0
37,0
8,7
750
6,0
36,0
35
28,4
1250
7,0
54,5
21,3
940
5,0
49,5
14,1
620
4,0
44,5
6,4
280
2,0
39,5
5,0
440
4,0
38,5
To obtain operating parameters concerning other water temperatures, please contact Sales Office.
V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Tw1 –inlet water temperature
Tw2 –outlet water temperature
Qw – water stream flow in the heat exchanger
Δpw – water pressure drop in the heat exchanger
Accessories
AGRO SP 6-SIDE AIR OUTLET
Material: ABS
Colour: RAL 9007
AGRO SP 6-side air outlet distributes
the air when heater is installed under
the ceiling.
Air flow zone
820
Benefits of using AGRO SP 6-side
air outlet:
• steady temperature distribution,
• better quality of bedding,
• lower concentration of ammonia,
• lower level of humidity in the room.
740
(1)
0,75–1,5 m
max. 12 m(1)
Range of horizontal isothermal air stream, at 0,5 m/s velocity limit
Indexes AGRO accessories
Name
AGRO SP 6-side air outlet
Index
10980
38 LEO AGRO
Air heating and ventilation
Control systems
LEO AGRO / AGRO SP fan heaters
ON/OFF regulation
It is the simplest ON/OFF regulation system. Fan heater is controlled by room thermostat, which turns on the unit when measured temperature drops below
a set temperature. Air flow is regulated by fan speed regulator.
FEATURES:
• low thermal inertia,
• low investment costs,
• easy to use,
• independent regulation of every single unit,
• gradual regulation of air flow.
SRQ
TRa
R55
min.
3×0,5 mm2
min.
3×1,0 mm2
min.
3×1,0 mm2
power supply
~230 V
min.
3×1,0 mm2
power supply
~230 V
• R55 thermostat controls SRQ2d valve,
• TRa fan speed regulator enables 5-step fan speed regulation,
• possibility of smooth (stepless) regulation, units can be controlled
by ON/OFF regulation or smoothly (stepless) by central computer
(microclimate controller).
SRQ
TRa
R55
min.
3×0,5 mm2
min.
3×1,0 mm2
min.
3×1,0 mm2
min.
3×1,0 mm2
power supply
~230 V
• R55 thermostat controls SRQ2d valve and TRa fan speed regulator,
• TRa regulator enables 5-step fan speed regulation.
Indexes LEO AGRO/AGRO SP control systems
Name
R 55
TR a
SRQ2d-¾
SRQ3d-¾
Index
10547
10531
10788
10805
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
www.flowair.com
39
40
www.flowair.com
Air curtains and
air curtain-fan heater combo units
www.flowair.com
41
Air curtains ELiS C
Air curtains ELiS C
Max. range(1) [m]
Heating capacity(2) [kW]
Weight [kg]
Colour
Casing
(1)
(2)
3
12,4–22,4
19,0–35,1
white (RAL 9016)
steel
Range of vertical isothermal air stream, at 1,5 m/s velocity limit
For C-W at inlet/outlet water temperature 90/70oC, inlet air temperature 10oC
Application:
Indexes ELiS C-W
Name
C-W-100
C-W-150
C-W-200
Index
14287
14288
14289
ELiS C air curtains are dedicated for public buildings like markets, sports halls, stores,
restaurants, etc. ELiS C units are designed for horizontal installation directly above the
door openings, which height does not exceed 3 m.
Indexes ELiS C-E
Available types of units:
Name
C-E-100
C-E-150
C-E-200
Index
14290
14291
14292
Available in 3 lengths: 1 m, 1,5 m or 2 m.
Available in 2 versions:
W – curtain with water heat exchanger
E – curtain with electric heaters
Special attributes
INSTALLATION BRACKETS
SIMPLE CONTROL
DIAGONAL FAN
HEATING ELEMENTS
Curtain is equipped in standard
with bracket, which enables horizontal installation of the unit.
possibility of operation according to temperature, change of
fan speed.
Curtain is equipped with highlyefficient diagonal fan with 3-step
motor.
Air curtains can be equipped
with PTC heating elements or
water heat exchanger made of
copper tubes and aluminum
fins.
Dimensions
C-W-150
(1)
(1)
C-E-150
1000
(1)
2000
C-E-200
1500
309
(1)
1500
1000
C-E-100
243
C-W-200
225
243
C-W-100
2000
196
112
Internal thread connection ¾”
42 ELiS C
Air curtains and air curtain-fan heater combo units
Technical data
Power supply [V/Hz]
Max. current consumption [A]
Max. power consumption [kW]
IP
Max. air flow steam of air curtain [m3/h]
Acoustic pressure level(1) [dB(A)]
Max. air steam range(2) [m]
Weight of unit [kg]
(1)
(2)
C-W-100
230/50
0,14
0,38
C-E-100
3x400/50
6,5
7,5
C-W-150
230/50
0,21
0,4
1400
46,5
2100
46,5
3000
48,5
19,0
14,5
27,5
C-E-150
3x400/50
10,0
11,5
C-W-200
230/50
0,26
0,44
C-E-200
3x400/50
13,0
15,5
1300
48,5
1950
50,5
2700
50,5
19,9
35,1
21
3
25,1
Acoustic pressure level measured for optimum installation height, on second step of efficiency, in the room with medium capability of sound absorption, capacity 500 m ,
at distance of 3 m from the unit
Range of vertical isothermal air stream, at 1,5 m/s velocity limit
3
Installation
max. 3 m
ELiS air curtains are equipped with
holders for installation using pins.
Air curtains and air curtain-fan heater combo units
ELiS C 43
Heating capacities
ELiS C-W-100
Tp1
V
PT
Qw
∆pw
°C
m3/h
kW
l/h
kPa
Tp2
PT
Qw
∆pw
C
kW
l/h
kPa
o
Tw1/Tw2 = 90/70°C
Tp2
o
C
Tw1/Tw2 = 80/60°C
0
14,2/15,8/17,0
625/698/749
15,4/18,8/21,3
40,0/37,5/36,0
12,2/13,6/14,6
537/599/643
12,0/14,7/16,7
34,5/32,5/31,0
5
13,3/14,8/15,9
587/655/703
13,7/16,7/19,0
42,5/40,0/38,5
11,3/12,7/13,6
498/556/596
10,5/12,8/14,5
37,0/35,0/33,5
12,4/13,8/14,9
547/611/655
12,1/14,7/16,7
45,0/42,5/41,0
10,4/11,6/12,5
458/512/549
9,1/11,0/12,5
39,5/37,5/36,5
15
11,5/12,8/13,8
507/566/608
10,5/12,9/14,6
47,0/45,0/44,0
9,5/10,6/11,4
418/467/501
7,7/9,4/10,6
41,5/40,0/39,0
20
10,6/11,8/12,7
467/522/560
9,1/11,1/12,6
49,5/47,5/46,5
8,6/9,6/10,3
378/422/453
6,4/7,8/8,9
44,0/42,5/41,5
10
1050/1250/1400
Tw1/Tw2 = 70/50°C
Tw1/Tw2 = 60/40°C
0
10,3/11,5/12,3
449/501/538
9,0/11,0/12,5
29,0/27,0/26,0
8,3/9,3/9,9
361/403/432
6,4/7,8/8,8
23,5/22,0/21,0
5
9,4/10,5/11,2
410/457/491
7,7/9,3/10,6
31,5/29,5/28,5
7,4/8,2/8,8
322/359/385
5,2/6,3/7,1
26,0/24,5/23,5
8,5/9,4/10,1
370/413/443
6,4/7,8/8,8
33,5/32,0/31,5
6,5/7,2/7,7
282/314/337
4,1/5,0/5,6
28,0/27,0/26,5
15
7,5/8,4/9,0
330/368/395
5,2/6,3/7,2
36,0/35,0/34,0
5,5/6,2/6,6
241/269/288
3,1/3,8/4,3
30,5/29,5/29,0
20
6,6/7,4/7,9
289/323/346
4,1/5,0/5,7
38,5/37,5/36,5
4,6/5,1/5,5
199/222/238
2,2/2,7/3,1
32,5/32,0/31,5
Tp2
PT
Qw
∆pw
Tp2
C
kW
l/h
kPa
10
1050/1250/1400
ELiS C-W-150
Tp1
V
PT
Qw
∆pw
°C
m3/h
kW
l/h
kPa
o
Tw1/Tw2 = 90/70°C
C
o
Tw1/Tw2 = 80/60°C
0
21,9/24,1/26,1
968/1062/1150
16,6/19,6/22,7
40,5/38,5/36,5
18,9/20,8/22,5
832/912/988
13,0/15,3/17,7
35,0/33,0/31,5
5
20,6/22,6/24,4
908/996/1078
14,8/17,5/20,2
43,0/41,0/39,5
17,6/19,3/20,8
772/846/916
11,3/13,4/15,4
37,5/35,5/34,5
10
19,2/21,1/22,8
847/930/1006
13,0/15,4/17,8
45,5/43,5/42,0
16,2/17,7/19,2
710/779/843
9,8/11,5/13,3
40,0/38,0/37,0
15
1600/1850/2100
17,8/19,5/21,1
786/862/933
11,4/13,4/15,5
47,5/46,0/44,5
14,8/16,2/17,5
649/712/770
8,3/9,8/11,3
42,0/40,5/39,5
20
16,4/18,0/19,5
724/794/860
9,8/11,6/13,4
50,0/48,5/47,0
13,4/14,6/15,8
587/643/696
6,9/8,2/9,4
44,5/43,0/42,0
Tw1/Tw2 = 70/50°C
Tw1/Tw2 = 60/40°C
0
15,9/17,5/18,9
696/764/826
9,7/11,5/13,2
29,5/28,0/26,5
12,9/14,1/15,3
561/615/666
6,9/8,1/9,3
24,0/22,5/21,5
5
14,5/15,9/17,2
636/697/754
8,3/9,8/11,2
32,0/30,5/29,0
11,5/12,6/13,6
500/548/593
5,6/6,6/7,6
26,0/25,0/24,0
13,1/14,4/15,6
574/630/681
6,9/8,1/9,4
34,0/33,0/32,0
10,0/11,0/11,9
438/480/519
4,4/5,2/6,0
28,5/27,5/26,5
15
10
1600/1850/2100
11,7/12,8/13,9
512/562/608
5,6/6,6/7,6
36,5/35,5/34,5
8,6/9,4/10,2
375/411/445
3,4/4,0/4,5
31,0/30,0/29,5
20
10,3/11,3/12,2
449/493/533
4,5/5,2/6,0
39,0/38,0/37,0
7,1/7,8/8,5
311/341/368
2,4/2,8/3,3
33,0/32,5/32,0
Tp2
PT
Qw
∆pw
Tp2
C
kW
l/h
kPa
ELiS C-W-200
Tp1
V
PT
Qw
∆pw
°C
m3/h
kW
l/h
kPa
o
Tw1/Tw2 = 90/70°C
C
o
Tw1/Tw2 = 80/60°C
0
31,4/34,0/37,1
1386/1498/1638
39,4/45,4/53,5
40,5/38,5/36,5
27,2/29,4/32,1
1194/1290/1411
30,9/35,6/41,9
35,0/33,5/31,5
5
29,5/31,9/34,8
1301/1406/1538
35,1/40,5/47,6
43,0/41,0/39,5
25,2/27,3/29,8
1108/1198/1310
27,0/31,1/36,6
37,5/36,0/34,5
27,5/29,8/32,5
1215/1313/1436
31,0/35,7/42,0
45,0/43,5/42,0
23,3/25,1/27,5
1022/1105/1207
23,3/26,9/31,6
40,0/38,5/37,0
15
10
2300/2600/3000
25,6/27,6/30,2
1128/1219/1333
27,1/31,2/36,7
47,5/46,0/44,5
21,3/23,0/25,1
935/1010/1104
19,9/22,9/26,8
42,0/41,0/39,5
20
23,6/25,5/27,9
1040/1125/1229
23,4/26,9/31,7
50,0/48,5/47,0
19,3/20,8/22,8
847/915/1000
16,6/19,1/22,4
44,5/43,5/42,0
Tw1/Tw2 = 70/50°C
Tw1/Tw2 = 60/40°C
0
22,9/24,8/27,1
1003/1084/1185
23,3/26,8/31,5
29,5/28,0/26,5
18,7/20,2/22,0
813/879/961
16,6/19,1/22,4
24,0/23,0/22,0
5
21,0/22,7/24,8
917/991/1084
19,8/22,8/26,8
32,0/30,5/29,5
16,7/18,0/19,7
727/786/859
13,6/15,6/18,3
26,5/25,5/24,5
10
19,0/20,5/22,4
830/897/981
16,6/19,1/22,4
34,5/33,0/32,0
14,7/15,9/17,3
639/691/755
10,8/12,4/14,5
29,0/28,0/27,0
15
2300/2600/3000
17,0/18,3/20,0
743/802/877
13,6/15,6/18,2
36,5/35,5/34,5
12,6/13,6/14,9
550/595/650
8,3/9,5/11,1
31,0/30,5/29,5
20
14,9/16,1/17,6
654/706/772
10,8/12,4/14,6
39,0/38,0/37,0
10,6/11,4/12,5
460/497/543
6,0/6,9/8,1
33,5/33,0/32,0
To obtain operating parameters concerning other water temperatures, please contact Sales Office.
V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Power supply [V/Hz]
Rated current(1) [A]
Heating capacity(1) [kW]
Air temperature rise for curtain (ΔT)(1) [°C]
(1)
Tw1 –inlet water temperature
Tw2 –outlet water temperature
Qw – water stream flow in the heat exchanger
Δpw – water pressure drop in the heat exchanger
1st step
C-E-100
2nd step
3rd step
1st step
8,8
6,1
18
9,1
6,4
16
9,4
6,5
15
13,7
9,5
18
C-E-150
2nd step
3x400/50
14,0
9,7
16
3rd step
1st step
C-E-200
2nd step
3rd step
14,5
10,0
15
18,1
12,5
18
18,5
12,8
16
18,7
13,0
15
At inlet air temperature 10oC
44 ELiS C
Air curtains and air curtain-fan heater combo units
Control systems
TS regulation
3-step fan speed regulator with thermostat
Controlling options
Manual 3-step air flow regulation
Controlling options
Heating / Ventilation
Operation depending on door contact and temperature
Weekly programmer
BMS
Switch-off delay
Idle speed mode
Integration with FLOWAIR System
Max. number of connected units
Via controller
Via 1 splitter RX
Via 2 splitters RX
Via 3 splitters RX
2
6(1)
12(1)
18(1)
Type of fan
AC – standard 3-step fan
(1)
Concerns ELiS C-W
ELiS C air curtains
TS regulation
DCet
TS
SRQ
DCm
SRQ
or
min.
2×1,0 mm2
min.
2×1,0 mm2
min.
3×0,5 mm2
power supply
~230 V
ELiS C-W min. 5×1,0 mm2
ELiS C-E min. 7×1,0 mm2
min. 5×4,0 mm2
3x400 V/50 Hz
ELiS C-E
min. 3×1,0 mm2
230 V/50 Hz
ELiS C-N/W
power supply
power supply
Indexes ELiS C control systems
Name
TS
D Cm
DCet
SR Q 2d -¾
SR Q3d -¾
Index
10996
14207
14261
10788
10805
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
Air curtains and air curtain-fan heater combo units
ELiS C 45
Air curtains ELiS T
Air curtains ELiS T
Max. range(1) [m]
Heating capacity(2) [kW]
Air flow [m3/h]
Weight [kg]
Colour
Casing
(1)
(2)
4
10,1–27,4
1900–5300
20,7–37
grey (similar to RAL 9007)
steel, plastic EPP (expanded polypropylene), aluminium
Range of vertical isothermal air stream, at velocity limit above 2 m/s
For T-W at inlet/outlet water temperature 90/70oC, inlet air temperature 10oC
Application:
Indexes ELiS T-N
Name
T-N-100
T-N-150
T-N-200
Index
14258
14259
14260
Representative buildings as well as industrial buildings. ELiS T curtains are designed for
horizontal installation directly above the door openings and for vertical installation on
both sides of door opening.
Indexes ELiS T-W
Name
T-W-100
T-W-150
T-W-200
Index
14252
14253
14254
Available types of units:
Available in 3 lengths: 1 m, 1,5 m or 2 m.
Available in 3 versions:
Indexes ELiS T-E
Name
T-E-100
T-E-150
T-E-200
Index
14255
14256
14257
N – curtain without heat exchanger (ambient)
W – curtain with water heat exchanger
E – curtain with electric heaters
Special attributes
SIMPLE CONSTRUCTION
BMS CONTROL SYSTEM
DIAGONAL FAN
HEATING ELEMENTS
Simple and lightweight construction thanks to combination of metal and plastic elements.
Control system makes it possible
to connect the units to the intelligent building management
system (BMS).
Curtain is equipped with highlyefficient diagonal fan with 3-step
motor.
Air curtains can be equipped
with PTC heating elements or
water heat exchanger made of
copper tubes and aluminum
fins.
Dimensions
T-N/W/E-200
300(1)
T-N/W/E-150
263
T-N/W/E-100
1045
1533
2023
377
428
(1)
Concerns ELiS T-W
46 ELiS T
Air curtains and air curtain-fan heater combo units
Technical data
T-N-100 T-W-100 T-E-100 T-N-150 T-W-150 T-E-150 T-N-200 T-W-200 T-E-200
230/50
230/50 3x400/50 230/50
230/50 3x400/50 230/50
230/50 3x400/50
1,8
1,7
11
1,9
1,8
16,6
2,1
2
22,4
0,39
0,38
7,5
0,42
0,4
11,5
0,46
0,44
15,5
21
2900
2300
2300
4000
3900
3900
5300
5100
5100
59
60
59
60
61
60
61
61
61
4
20,7
22,1
24
27
29,5
31,5
31,5
34,3
37
Power supply [V/Hz]
Max. current consumption [A]
Max. power consumption [kW]
IP
Max. air flow steam of air curtain [m3/h]
Acoustic pressure level(1) [dB(A)]
Max. air steam range(2) [m]
Weight of unit [kg]
Acoustic pressure level measured for optimum installation height, on second step of efficiency, in the room with medium capability of sound absorption, capacity 500 m3,
at distance of 3 m from the unit
(2)
Range of vertical isothermal air stream, at velocity limit above 2 m/s
(1)
Installation
Optional installation console enables easy and
quick installation of the
air curtain on the wall in
two ways.
ELiS T air curtains are
equipped with holders for installation
using pins.
or
max. 6
max. 4 m
min. 0,2 m
Possibility of vertical
installation of ELiS T air
curtains using brackets.
m
Indexes brackets
Name
bra ckets E LiS
b rac ket s MPK
Index
14250
14262
Air curtains and air curtain-fan heater combo units
ELiS T 47
Heating capacities
ELiS T-W-100
Tp1
V
PT
Qw
∆pw
°C
m3/h
kW
l/h
kPa
Tp2
PT
Qw
∆pw
C
kW
l/h
kPa
o
Tw1/Tw2 = 90/70°C
Tp2
C
o
Tw1/Tw2 = 80/60°C
0
11,7/12,3/12,9
516/544/571
1,7/1,8/2
18/17,5/17
9,8/10,3/10,8
430/454/476
1,2/1,4/1,5
15/14,5/14
5
10,9/11,5/12
480/507/531
1,5/1,6/1,8
22/21,5/21
9/9,5/9,9
394/415/436
1,1/1,2/1,3
19/18,5/18
22,5/22/21,5
10,1/10,6/11,1
444/469/492
1,3/1,4/1,5
25,5/25/24,5
8,1/8,6/9
357/377/395
0,9/1/1,1
15
10
1900/2100/2300
9,3/9,8/10,2
408/430/451
1,1/1,2/1,3
29/28,5/28
7,3/7,7/8,1
321/338/355
0,7/0,8/0,9
26/25,5/25
20
8,4/8,9/9,3
372/392/411
0,9/1/1,1
33/32,5/32
6,5/6,8/7,1
283/299/314
0,6/0,6/0,7
30/29,5/29
0
7,8/8,3/8,7
342/361/379
0,8/0,9/1
12/11,5/11
5,7/6/6,3
248/262/276
0,5/0,5/0,6
9/8,5/8
5
7/7,4/7,7
305/322/338
0,7/0,8/0,8
16/15,5/15
4,8/5/5,3
207/220/232
0,4/0,4/0,4
12,5/12/11,5
Tw1/Tw2 = 70/50°C
10
1900/2100/2300
Tw1/Tw2 = 60/40°C
6,1/6,5/6,8
267/282/296
0,5/0,6/0,7
19,5/19/18,5
3,7/3,9/4,2
159/172/183
0,2/0,3/0,3
16/15,5/15
15
5,2/5,5/5,8
229/242/254
0,4/0,5/0,5
23/22,5/22
1,9/2/2,1
85/87/89
0,1/0,1/0,1
18,5/18/17,5
20
4,3/4,6/4,8
188/199/210
0,3/0,3/0,4
27/26,5/26
1,6/1,6/1,7
70/71/73
0,1/0,1/0,1
22,5/22/22
Tp2
PT
Qw
∆pw
Tp2
C
kW
l/h
kPa
ELiS T-W-150
Tp1
V
PT
Qw
∆pw
°C
m3/h
kW
l/h
kPa
o
Tw1/Tw2 = 90/70°C
o
C
Tw1/Tw2 = 80/60°C
0
20,6/21,9/23,2
907/968/1026
5,8/6,5/7,2
19,5/18,5/17,5
17,5/18,7/19,8
769/821/870
4,4/4,9/5,5
17/16/15
5
19,2/20,5/21,7
848/905/959
5,1/5,8/6,4
23/22/21
16,2/17,3/18,3
710/758/802
3,8/4,3/4,7
20,5/19,5/18,5
17,9/19,1/20,2
789/842/892
4,5/5/5,6
27/26/25
14,8/15,8/16,7
650/694/735
3,2/3,6/4
24,5/23,5/22,5
15
10
3100/3500/3900
16,5/17,7/18,7
730/779/824
3,9/4,4/4,8
31/30/29
13,4/14,3/15,2
591/630/667
2,7/3,1/3,4
28/27/26
20
15,2/16,2/17,2
670/715/757
3,3/3,7/4,1
34,5/33,5/32,5
12,1/12,9/13,6
530/566/599
2,2/2,5/2,8
32/31/30
Tw1/Tw2 = 70/50°C
Tw1/Tw2 = 60/40°C
0
14,4/15,4/16,3
631/674/714
3,2/3,6/4
14/13/12
11,3/12/12,8
492/525/556
2,1/2,4/2,6
11/10/9
5
13,1/13,9/14,8
572/610/646
2,6/3/3,3
18/17/16
9,9/10,6/11,2
431/460/487
1,7/1,9/2,1
15/14/13
10
11,7/12,5/13,2
511/546/578
2,2/2,4/2,7
22/21/20
8,5/9/9,6
369/394/417
1,3/1,4/1,6
18,5/17,5/16,5
15
3100/3500/3900
10,3/11/11,6
450/481/509
1,7/1,9/2,1
25,5/24,5/23,5
7/7,5/7,9
305/327/346
0,9/1/1,1
22,5/21,5/20,5
20
8,9/9,5/10
389/415/439
1,3/1,5/1,6
29,5/28,5/27,5
5,5/5,9/6,2
239/256/272
0,6/0,7/0,07
26/25/24
Tp2
PT
Qw
∆pw
Tp2
C
kW
l/h
kPa
ELiS T-W-200
Tp1
V
PT
Qw
∆pw
°C
m3/h
kW
l/h
kPa
o
Tw1/Tw2 = 90/70°C
C
o
Tw1/Tw2 = 80/60°C
0
23,5/28/31,4
1037/1234/1387
8,5/11,7/14,5
23/20/18
20,2/24/26,9
885/1052/1183
6,5/9/11,1
19/17/15
5
22/26,2/29,4
972/1155/1299
7,5/10,3/12,8
27/24/22
18,6/22,2/24,9
819/974/1095
5,7/7,8/9,6
23,5/21/19,5
27/24,5/23
20,5/24,4/27,4
906/1077/1211
6,6/9,1/11,3
30/27/26
17,1/20,4/22,9
753/895/1005
4,9/6,7/8,2
15
10
3000/4100/5100
19/22,6/25,4
840/998/1122
5,8/7,9/9,8
34/31/29
15,6/18,6/20,8
686/815/916
4,1/5,6/7
30/28/27
20
17,5/20,8/23,4
774/919/1033
5/6,8/8,4
38/35/33
14,1/16,7/18,8
619/735/826
3,4/4,7/5,8
33,5/32/30,5
0
16,8/19,9/22,4
733/872/980
4,8/6,6/8,1
16,5/14,5/12,5
13,3/15,8/17,8
581/690/776
3,3/4,5/5,5
13/11,5/10
5
15,2/18,1/20,6
667/792/891
4/5,5/6,8
20/18/16
11,8/14/15,7
513/610/686
2,6/3,6/4,4
16,5/15/14
Tw1/Tw2 = 70/50°C
10
3000/4100/5100
Tw1/Tw2 = 60/40°C
13,7/16,3/18,3
600/713/801
3,3/4,6/5,6
23,5/21,5/20,5
10,2/12,1/13,6
445/529/595
2/2,7/3,4
20/19/18
15
12,2/14,5/16,2
532/632/710
2,7/3,7/4,5
27/25/24
8,6/10,2/11,5
376/447/502
1,5/2/2,5
23,5/22,5/21,5
20
10,6/12,6/14,4
464/551/619
2,1/2,9/3,5
30,5/28,5/27,5
7/8,3/9,4
304/362/408
1/1,4/1,7
26,5/25,5/25
To obtain operating parameters concerning other water temperatures or air curtains with more heating capacity, please contact Sales Office.
V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Power supply [V/Hz]
Rated current(1) [A]
Heating capacity(1) [kW]
Air temperature rise for curtain (ΔT)(1) [°C]
(1)
Tw1 –inlet water temperature
Tw2 –outlet water temperature
Qw – water stream flow in the heat exchanger
Δpw – water pressure drop in the heat exchanger
1st step
T-E-100
2nd step
3rd step
1st step
10,2
7,1
12
10,5
7,3
12
11
7,5
11
15,9
11
13
T-E-150
2nd step
3x400/50
16,1
11,2
12
3rd step
1st step
T-E-200
2nd step
3rd step
16,6
11,5
12
21,5
14,9
14
21,8
15,1
14
22,4
15,5
13
At inlet air temperature 10oC
Indexes ELiS T control system
48 ELiS T
Name
T- b ox
DRV ELiS
TS
DCm
D Ce t
DCe
Index
10799
90541
10996
14207
14261
14212
SR Q2 d - ½ S R Q 3 d - ½
10803
10804
Air curtains and air curtain-fan heater combo units
Control systems
TS regulation
T-box regulation
3-step fan speed regulator with thermostat
Intelligent controller with touch
screen
2
6
12
18
31
n/a
n/a
n/a
Controlling options
Manual 3-step air flow regulation
Controlling options
Heating / Ventilation
Operation depending on door contact and temperature
Weekly programmer
BMS
Switch-off delay
Idle speed mode
Integration with FLOWAIR System
Max. number of connected units
Via controller
Via 1 splitter RX
Via 2 splitters RX
Via 3 splitters RX
Type of fan
AC – standard 3-step fan
ELiS T air curtains
TS regulation
TS
DCet
SRQ
DCm
SRQ
or
min.
2×1,0 mm2
min.
2×1,0 mm2
min.
3×0,5 mm2
power supply
~230 V
min.
5×1,0 mm2
min. 5×4,0 mm2
3x400 V/50 Hz
ELiS T-E
min. 3×1,0 mm2
230 V/50 Hz
ELiS T-N/W
power supply
power supply
ELiS T air curtains
T-box regulation
T-box
DCe
SRQ
DCm
SRQ
or
DRV ELiS
LIYCY min. 4x0,5 mm2
A and B braided wire
pair max. 50 m
LIYCY min. 3x0,5 mm
A and B braided wire
pair max. 50 m
2
min.
4×1,0 mm2
min.
3×0,5 mm2
min.
2×0,5 mm2
min.
3×1,0 mm2
power supply
~230 V
DRV ELiS
min. 5×4,0 mm2
3x400 V/50 Hz
ELiS T-E
min. 3×1,0 mm2
230 V/50 Hz
ELiS T-N/W
power supply
power supply
~230 V
max 31 devices compatible
with FLOWAIR System
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
Air curtains and air curtain-fan heater combo units
ELiS T 49
Air curtains ELiS B
Air curtains ELiS B
Max. range(1) [m]
Heating capacity(2) [kW]
Air flow [m3/h]
Weight [kg]
Colour
Casing
(1)
(2)
5
10,9–27,7
2200–6600
31,7–53,2
white (RAL 9016)
steel, plastic, EPP (expanded polypropylene), aluminium
Range of vertical isothermal air stream, at velocity limit above 2 m/s
For B-W at inlet/outlet water temperature 90/70oC, inlet air temperature 10oC
Application:
Representative rooms like stores, restaurants, showrooms etc. ELiS B units are designed
for installation in suspended ceilings. Their advantage is the possibility of installation in
existing ceiling without cutting additional holes.
Indexes ELiS B-N
Name
B-N-100
B-N-150
B-N-200
Index
14281
14282
14283
Available types of units:
Indexes ELiS B-W
Name
B-W-100
B-W-150
B-W-200
Index
14275
14276
14277
Available in 3 lengths: 1 m, 1,5 m or 2 m.
Available in 3 versions:
N – curtain without heat exchanger (ambient)
Indexes ELiS B-E
Name
B-E-100
B-E-150
B-E-200
Index
14278
14279
14280
W – curtains with water heat exchanger
E – curtain with electric heaters
Special attributes
SIMPLE CONSTRUCTION
BMS CONTROL SYSTEM
DIAGONAL FAN
AIR BLADES
Simple and lightweight construction thanks to combination of
metal and plastic elements.
Control system makes it possible
to connect the units to the intelligent building management system (BMS).
Curtain is equipped with highlyefficient diagonal fan with 3-step
motor.
Adjustment of air stream to door
opening thanks to regulated air
outlet.
Dimensions
B-N/W/E-150
B-N/W/E-200
600
B-N/W/E-100
1546
2034
284
300(1)
1057
(1)
Concerns ELiS B-W
50 ELiS B
Air curtains and air curtain-fan heater combo units
Technical data
Power supply [V/Hz]
Max. current consumption [A]
Max. power consumption [kW]
IP
Max. air flow stream of air curtain [m3/h]
Acoustic pressure level(1) [dB(A)]
Max. air stream range(2) [m]
Weight of unit [kg]
B-N-100 B-W-100 B-E-100 B-N-150 B-W-150 B-E-150 B-N-200 B-W-200 B-E-200
230/50
230/50 3x400/50 230/50
230/50 3x400/50 230/50
230/50 3x400/50
1,9
1,5
11
2
1,6
16,6
2,2
1,7
22,4
0,42
0,34
7,5
0,44
0,36
11,5
0,49
0,38
15,5
21
3500
2600
2600
4800
4000
4000
6600
5200
5200
58
60
58
59
60
59
61
63
61
5
31,7
32,3
34,5
38,9
41,2
42,4
47,2
50
53,2
Acoustic pressure level measured for optimum installation height, on second step of efficiency, in the room with medium capability of sound absorption, capacity 500 m3,
at distance of 3 m from the unit
(2)
Range of vertical isothermal air stream, at velocity limit above 2 m/s
(1)
Installation
ELiS B air curtains are equipped as a standard with holders, which enable installation on suspended ceilings. Casing of the unit was designed to enable
installation in already existing ceilings, without cutting bigger holes or service hatches.
Installation of the unit
does not require preparing additional holes in
the ceiling.
Access from the
front makes easier
installation, connection and cleaning of the curtain.
max. 5 m
Brackets for installation using pins as
a standard equipment.
Air curtains and air curtain-fan heater combo units
ELiS B 51
Heating capacities
ELiS B-W-100
Tp1
°C
V
m3/h
PT
kW
Qw
l/h
Δpw
kPa
2200/2500/2600
12,6/13,5/13,8
11,8/12,6/12,8
10,9/11,6/11,9
10,0/10,7/10,9
9,1/9,7/9,9
558/597/609
519/555/566
480/513/524
441/471/481
402/429/438
2200/2500/2600
8,5/9,0/9,2
7,5/8,1/8,2
6,6/7,1/7,2
5,7/6,1/6,2
4,7/5,0/5,1
370/396/404
330/353/360
290/310/316
248/266/271
204/220/225
V
m3/h
PT
kW
Qw
l/h
3200/3500/4000
20,9/21,9/23,5
19,6/20,5/22,0
18,2/19,1/20,5
16,8/17,6/19,0
15,5/16,2/17,4
923/968/1039
863/905/972
803/842/904
742/779/835
682/715/767
Tp2
°C
PT
kW
Qw
l/h
17,0/16,0/15,5
21,0/20,0/19,5
24,5/23,5/24,5
28,0/27,5/27,0
32,0/31,5/31,0
10,6/11,3/11,5
9,7/10,4/10,6
8,8/9,4/9
7,9/8,5/8,6
7,0/7,5/7,6
465/497/507
426/455/464
386/413/395
347/370/378
306/328/334
1,0/1,1/1,2
0,7/0,8/0,9
0,6/0,6/0,7
0,5/0,5/0,6
0,3/0,4/0,4
11,5/11,0/10,5
15,0/14,5/14,0
19,0/18,5/18,0
22,5/22,0/21,5
26,0/25,5/25,0
6,2/6,6/6,8
5,2/5,6/5,7
4,1/4,5/4,6
2,0/2,1/2,1
1,6/1,7/1,7
269/289/295
226/243/249
178/193/198
88/90/91
72/74/74
0,6/0,6/0,7
0,4/0,4/0,5
0,3/0,3/0,3
0,1/0,1/0,1
0,1/0,1/0,1
8,5/8,0/7,5
12,0/12,0/11,5
15,5/15,0/15,0
18,0/17,5/17,5
22,5/22,0/22,0
Δpw
kPa
Tp2
°C
PT
kW
Qw
l/h
Δpw
kPa
Tp2
°C
19,6/18,5/17,5
23,0/22,5/21,5
27,0/26,0/25,0
30,5/30,0/30,0
34,0/33,5/32,5
17,8/18,7/20,0
16,4/17,3/18,5
15,0/15,8/17,0
13,7/14,3/15,4
12,3/12,9/13,8
783/821/881
722/758/813
662/694/745
601/630/676
539/566/607
Tw1/Tw2 = 90/70oC
0
5
10
15
20
Tp2
°C
Tw1/Tw2 = 80/60oC
1,9/2,2/2,3
1,7/1,9/2,0
1,5/1,6/1,7
1,3/1,4/1,5
1,1/1,2/1,2
Tw1/Tw2 = 70/50oC
0
5
10
15
20
Δpw
kPa
1,4/1,6/1,7
1,2/1,3/1,4
1,0/1,1/1,1
0,8/0,9/1,0
0,7/0,8/0,8
14,0/13,5/13,0
18,0/17,5/17,0
21,5/21,0/21,5
25,5/25,0/24,5
29,5/29,0/28,5
Tw1/Tw2 = 60/40oC
ELiS B-W-150
Tp1
°C
Tw1/Tw2 = 90/70oC
0
5
10
15
20
Tw1/Tw2 = 80/60oC
5,9/6,5/7,4
5,3/5,6/6,6
4,6/5,0/5,7
4,0/4,4/5,0
3,4/3,7/4,2
Tw1/Tw2 = 70/50oC
0
5
10
15
20
4,5/4,9/5,6
3,9/4,3/4,9
3,3/3,6/4,1
2,8/3,0/3,5
2,3/2,5/2,8
16,5/16,0/15,0
20,0/19,5/18,5
24,0/23,0/22,5
27,5/27,0/26,5
31,0/30,5/30,0
Tw1/Tw2 = 60/40oC
3200/3500/4000
14,7/15,4/16,5
13,3/13,9/15,0
11,9/12,5/13,4
10,5/11,0/11,78
9,0/9,5/10,2
642/674/723
581/610/655
520/546/585
458/481/516
395/415/445
3,3/3,6/4,0
2,7/3,0/3,4
2,2/2,4/2,8
1,8/1,9/2,2
1,4/1,5/1,7
13,5/13,0/12,5
17,5/16,5/16,0
21,0/20,5/20,0
24,5/24,0/23,5
28,0/27,5/27,5
V
m3/h
PT
kW
Qw
l/h
Δpw
kPa
Tp2
°C
4000/4300/5200
27,6/28,7/31,8
25,8/26,9/29,7
24,0/25,0/27,7
22,3/23,2/25,7
20,5/21,4/23,6
1217/1266/1402
1140/1186/1312
1063/1105/1223
985/1024/1133
907/943/1043
4000/4300/5200
19,7/20,5/22,5
17,9/18,6/20,5
16,1/16,7/18,5
14,5/14,8/16,4
12,4/12,9/14,3
860/894/990
782/813/900
703/731/809
624/649/717
544/565/625
11,5/12,0/13,0
10,1/10,5/11,5
8,6/9,0/9,7
7,1/7,5/8,1
5,6/5,9/6,3
500/525/563
438/460/494
375/394/423
311/327/351
243/256/276
2,2/2,4/2,7
1,7/1,9/2,1
1,3/1,4/1,6
0,9/1,0/1,1
0,6/0,7/0,7
10,5/10,0/9,5
14,5/14,0/13,5
18,0/17,5/17,0
21,5/21,0/21,0
25,0/24,5/24,5
PT
kW
Qw
l/h
Δpw
kPa
Tp2
°C
20,5/19,5/18,0
24,0/23,5/22,0
27,5/27,0/25,7
32,5/30,5/29,5
35,0/34,5/33,0
23,6/24,6/27,7
21,9/22,7/25,2
20,1/20,9/23,1
18,3/19,0/21,0
16,5/17,2/19,0
1038/1080/1195
961/999/1106
883/918/1016
804/836/925
725/754/834
14,5/14,0/13,0
18,0/17,5/17,0
21,5/21,5/20,5
25,5/25,0/24,5
29,0/28,5/28,0
15,6/16,3/18,0
13,8/14,4/15,9
12,0/12,5/13,8
10,1/10,5/11,6
8,2/8,5/9,5
681/708/784
602/626/693
522/543/601
441/458/507
357/372/412
ELiS B-W-200
Tp1
°C
Tw1/Tw2 = 90/70oC
0
5
10
15
20
Tw1/Tw2 = 80/60oC
11,4/12,2/14,7
10,0/10,8/13,0
8,9/9,5/11,5
7,7/8,3/10,0
6,6/7,1/8,8
Tw1/Tw2 = 70/50oC
0
5
10
15
20
8,7/9,4/11,3
7,6/8,2/9,8
6,5/7,0/8,4
5,5/5,9/7,1
4,6/4,9/5,9
17,5/17,0/15,5
21,1/20,5/19,5
25,0/24,5/22,5
28,5/28,0/27,0
32,0/31,5/30,5
Tw1/Tw2 = 60/40oC
6,4/6,9/8,3
5,4/5,8/6,9
4,5/4,7/5,7
3,6/3,8/4,6
2,8/3,0/3,6
4,6/4,7/5,6
3,5/3,7/4,5
2,7/2,9/3,5
2,0/2,1/2,6
1,4/1,5/1,8
11,5/11,0/10,5
15,0/15,0/14,0
18,5/18,5/18,0
22,5/22,0/21,5
26,0/25,5/25,0
To obtain operating parameters concerning other water temperatures or air curtains with more heating capacity, please contact Sales Office.
V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Power supply [V/Hz]
Rated current of unit(1) [A]
Heating capacity(1) [kW]
Air temperature rise for curtain (ΔT)(1) [°C]
(1)
Tw1 –inlet water temperature
Tw2 –outlet water temperature
Qw – water stream flow in the heat exchanger
Δpw – water pressure drop in the heat exchanger
1 step
B-E-100
2 step
3 step
1 step
10,2
7,1
12
10,5
7,3
12
11
7,5
11
15,9
11
13
B-E-150
2 step
3x400/50
16,1
11,2
12
3 step
1 step
B-E-200
2 step
3 step
16,6
11,5
12
21,5
14,9
14
21,8
15,1
14
22,4
15,5
13
At inlet air temperature 10oC
52 ELiS B
Air curtains and air curtain-fan heater combo units
Control systems
TS regulation
T-box regulation
3-step fan speed regulator with thermostat
Intelligent controller with touch
screen
5
n/a
n/a
n/a
31
n/a
n/a
n/a
Controlling options
Manual 3-step air flow regulation
Controlling options
Heating / Ventilation
Operation depending on door contact and temperature
Weekly programmer
BMS
Switch-off delay
Idle speed mode
Integration with FLOWAIR System
Max. number of connected units
Via controller
Via 1 splitter RX
Via 2 splitters RX
Via 3 splitters RX
Type of fan
AC – standard 3-step fan
ELiS B air curtains
TS regulation
DCe
TS
DCm
SRQ
SRQ
or
min.
5×0,5 mm2
min.
2×0,5 mm2
LIYCY min. 3x0,5 mm2
A and B braided wire
pair max. 50 m
min.
3×0,5 mm2
min. 5×4,0 mm2
3x400 V/50 Hz
ELiS B-E
min. 3×1,0 mm2
230 V/50 Hz
ELiS B-N/W
power supply
power supply
SRQ
max. 5 units
ELiS B
power supply
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
Air curtains and air curtain-fan heater combo units
ELiS B 53
Control systems
ELiS B air curtains
T-box regulation
T-box
DCe
SRQ
DCm
SRQ
or
min.
2×0,5 mm2
min.
3×0,5 mm2
LIYCY min. 4x0,5 mm2
A and B braided wire
pair max. 50 m
LIYCY min. 3x0,5 mm2
A and B braided wire
pair max. 50 m
min. 5×4,0 mm2
3x400 V/50 Hz
ELiS B-E
min. 3×1,0 mm2
230 V/50 Hz
ELiS B-N/W
power supply
power supply
SRQ
max 31 devices compatible
with FLOWAIR System
power supply
Indexes ELiS B control systems
Name
T-box
TS
DCm
DCe
SR Q2d -½
SR Q3 d- ½
Index
10799
10996
14207
14212
10803
10804
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
54 ELiS B
Air curtains and air curtain-fan heater combo units
Air curtains ELiS A
Air curtains ELiS A
Max. range(1) [m]
Heating capacity(2) [kW]
Air flow [m3/h]
Weight [kg]
Colour
Casing
(1)
(2)
3
12,3–28,0
850–3500
18,4–39,0
grey (RAL 9006) / white (RAL 9010)
steel, plastic
Range of vertical isothermal air stream, at velocity limit above 2 m/s
For A-W at inlet/outlet water temperature 90/70oC, inlet air temperature 10oC
Application:
Representative rooms like stores, restaurants, showrooms etc. ELiS A units are designed for
horizontal installation directly above door openings. They form an air stream, which reduces
losses associated with air exchange between the building and its surroundings.
Indexes ELiS A-N grey/white
Name
A-N-100
A-N-150
A-N-200
Index
14235/14263
14236/14264
14237/14265
Available types of units:
Indexes ELiS A-W grey/white
Name
A-W-100
A-W-150
A-W-200
Index
14233/14266
14230/14267
14238/14268
Available in 3 lengths: 1 m, 1,5 m or 2 m.
Available in 3 versions:
N – curtain without heat exchanger (ambient)
Indexes ELiS A-E grey/white
Name
A-E-100
A-E-150
A-E-200
Index
14239/14269
14240/14245
14241/14251
W – curtain with water heat exchanger
E – curtain with electric heaters
Special attributes
SIMPLE CONSTRUCTION
QUIET FANS
BMS CONTROL SYSTEM
MODERN DESIGN
Adjustable air outlet enables the
user to set the right angle of the
air stream.
Radial fans are closed in the casing made of light, durable and
sound-absorbing material. They
are characterized by quiet operation and low power consumption
in relation to their efficiency.
Advanced control system makes
it possible to chain the units and
to easy control them by the intelligent building management system (BMS).
Modern design of the unit
came into existence in cooperation with an experienced
team of industrial designers.
Dimensions
A-N/W/E-150
A-N/W/E-200
440(1)
390
A-N/W/E-100
356
1125
(1)
1580
2040
393
Concerns ELiS A-W
Air curtains and air curtain-fan heater combo units
ELiS A 55
Technical data
Power supply [V/Hz]
Max. current consumption [A]
Max. power consumption [kW]
IP
Max. air flow stream of air curtain [m3/h]
Acoustic pressure level(1) [dB(A)]
Max. air stream range(2) [m]
Weight of unit [kg]
(1)
(2)
A-N-100 A-W-100 A-E-100
230/50
3x400/50
0,72
10
0,17
7
1500
43
18,4
20,9
21,4
A-N-150 A-W-150 A-E-150
230/50
3x400/50
1,1
15,5
0,25
10,7
21
2500
46
3
25,3
28,3
28,5
A-N-200 A-W-200 A-E-200
230/50
3x400/50
1,45
21,5
0,34
15
3500
48
33,6
37,1
39
Acoustic pressure level measured for optimum installation height, on second step of efficiency, in the room with medium capability of sound absorption, capacity 500 m ,
at distance of 3 m from the unit
Range of vertical isothermal air stream, at velocity limit above 2 m/s
3
Installation
Two ways of console
assembly.
or
max. 3 m
min. 0,2 m
ELiS air curtains are
equipped with holders for
installation using pins.
Indexes brackets
Name
bra ckets E L i S
Index
14250
The key to the correct operation of the unit is to ensure air barrier on entire door opening plane. ELiS A are ready for chaining, so covering wider door openings
is not a problem.
56 ELiS A
Air curtains and air curtain-fan heater combo units
Heating capacities
ELiS A-W 100
Tp1
°C
V
m3/h
PT
kW
Qw
Δpw
l/h
kPa
Tw1/Tw2 = 90/70oC
Tp2
o
C
PT
kW
Qw
Δpw
l/h
kPa
Tw1/Tw2 = 80/60oC
Tp2
o
C
0
14,4/17,7/21,0
637/781/927
4,4/6,4/8,8
47/43/39
12,4/15,2/18,0
545/668/793
3,4/5,0/6,8
40/37/33
5
13,3/16,4/19,4
588/721/857
3,8/5,5/7,6
49/45/41
11,3/13,9/16,5
497/610/724
2,9/4,2/5,7
43/39/36
10
12,3/15,0/17,9
541/663/788
3,3/4,8/6,5
51/47/44
10,3/12,6/15,0
451/553/657
2,4/3,5/4,8
45/41/39
15
850/1150/1500
11,2/13,7/16,3
494/606/721
2,8/4,0/5,5
53/50/47
9,2/11,3/13,5
405/497/591
2,0/2,9/4,0
47/44/41
20
10,2/12,5/14,8
448/550/654
2,3/3,4/4,6
55/52/49
8,2/10,1/12,0
360/442/526
1,6/2,4/3,2
49/46/44
Tw1/Tw2 = 70/50oC
Tw1/Tw2 = 60/40oC
0
10,4/12,7/15,1
453/555/659
2,5/3,7/5,0
34/31/28
8,3/10,1/12,0
360/442/525
1,8/2,5/3,4
27/24/22
5
9,3/11,4/13,5
407/498/592
2,1/3,0/4,1
36/33/30
7,2/8,9/10,5
315/386/459
1,4/2,0/2,7
29/27/25
31/29/27
8,3/10,1/12,0
361/443/526
1,7/2,4/3,3
38/35/33
6,2/7,6/9,0
269/331/394
1,0/1,5/2,0
15
10
850/1150/1500
7,2/8,9/10,5
316/388/461
1,3/1,9/2,6
40/37/35
5,1/6,3/7,5
224/276/329
0,8/1,1/1,5
33/31/30
20
6,2/7,6/9,1
271/334/397
1,0/1,5/2,0
42/40/38
4,1/5,1/6,1
177/220/264
0,5/0,7/1,0
34/33/32
ELiS A-W 150
Tp1
°C
V
m3/h
PT
kW
Qw
Δpw
l/h
kPa
Tw1/Tw2 = 90/70oC
Tp2
o
C
PT
kW
Qw
Δpw
l/h
kPa
Tw1/Tw2 = 80/60oC
Tp2
o
C
0
17,9/20,7/22,9
791/914/1011
5,3/6,9/8,3
32/29/27
15,3/17,7/19,6
672/777/861
4/5,6/6,3
27/25/23
5
16,8/19,4/21,4
740/855/946
4,7/6,1/7,4
35/32/30
14,1/16,3/18,1
621/718/795
3,5/4,5/5,5
30/28/26
15,6/18/20
688/795/881
4,1/5,3/6,5
38/35/34
13/15/16,6
569/658/728
3/3,9/4,7
33/31/30
15
10
1650/2100/2500
14,4/16,7/18,5
636/735/814
3,5/4,6/5,6
41/38/37
11,8/13,6/15
517/597/661
2,5/3,2/3,9
36/34/33
20
13,2/15,3/17
584/674/748
3/3,9/4,8
43/41/40
10,6/12,2/13,5
464/532/593
2/2,7/3,2
39/37/36
Tw1/Tw2 = 70/50oC
Tw1/Tw2 = 60/40oC
0
12,7/14,6/16,2
554/640/709
2,9/3,8/4,6
23/21/19
10/11,5/12,8
434/502/556
1,9/2,5/3
18/16/15
5
11,5/13,3/14,7
502/580/643
2,4/3,2/3,8
26/24/22
9/10,1/11,2
381/441/489
1,5/2/2,4
21/19/18
10
10,3/11,9/13,2
450/520/576
2/2,6/3,1
28/27/26
7,5/8,7/9,7
328/380/421
1,2/1,5/1,8
23/22/21
15
1650/2100/2500
9,1/10,5/11,6
397/459/508
1,6/2,1/2,5
31/30/29
6,3/7,3/8
273/316/351
0,8/1,1/1,3
26/25/24
20
7,84/9,1/10
343/397/439
1,2/1,6/1,9
34/33/32
4,9/5,7/6,4
214/250/279
0,6/0,7/0,9
29/28/27
ELiS A-W 200
Tp1
°C
V
m3/h
PT
kW
Qw
Δpw
l/h
kPa
Tw1/Tw2 = 90/70oC
Tp2
o
C
PT
kW
Qw
Δpw
l/h
kPa
Tw1/Tw2 = 80/60oC
Tp2
o
C
0
25,7/29/32,2
1135/1271/1419
12/14,5/18
32/29/27
22/24,7/27,6
970/1086/1212
9/11,1/13,6
27/25/23
5
24/27/30
1063/1191/1329
10,4/13/16
35/32/30
20,4/22,9/25,5
898/1006/1122
7,8/9,7/11,8
30/28/27
22,5/25,1/28
992/1110/1240
9,2/11,3/14
38/36/34
18,8/21/23,5
825/924/1031
6,7/8,3/10,1
33/31/30
15
10
2400/2900/3500
20,8/23,3/26
918/1027/1147
7,9/9,8/12
40/38/37
17,1/19,1/21,4
751/841/939
5,7/7/8,5
36/34/33
20
19/21,4/24
844/945/1054
6,8/8,4/10,3
43/42/40
15,4/17,3/19,2
677/758/845
4,7/5,8/7
39/37/36
Tw1/Tw2 = 70/50oC
Tw1/Tw2 = 60/40oC
0
18,4/20,6/23
805/902/1007
6,6/8,1/10
23/21/20
14,7/16,5/18,4
641/717/801
4,5/5,5/6,7
18/17/16
5
16,8/18,8/21
733/821/916
5,6/6,9/8,4
26/24/23
13/14,6/16,3
568/636/709
3,6/4,5/5,4
21/20/19
10
15,1/16,9/18,9
660/739/824
4,6/5,7/6,9
29/27/26
11,3/12,7/14,1
493/552/616
2,8/3,5/4,2
24/23/22
15
2400/2900/3500
13,4/15/16,7
586/655/731
3,7/4,6/5,6
31/30/29
9,6/11/12
418/468/522
2/2,6/3,1
27/26/25
20
11,7/13/14,6
510/571/637
2,9/3,5/4,3
34/33/32
7,8/8,7/9,8
340/381/425
1,4/1,8/2,2
30/29/28
To obtain operating parameters concerning other water temperatures, please contact Sales Office.
V – air flow
Tw1 –inlet water temperature
PT – heating capacity
Tw2 –outlet water temperature
Tp1 – inlet air temperature
Qw – water stream flow in the heat exchanger
Tp2 – outlet air temperature
Δpw – water pressure drop in the heat exchanger
Power supply [V/Hz]
Rated current of unit(1) [A]
Heating capacity(1) [kW]
Air temperature rise for curtain (ΔT)(1) [°C]
(1)
1 step
A-E-100
2 step
3 step
1 step
9,5
6,6
27
9,8
6,8
26
10
7
25
14,8
10,2
24
A-E-150
2 step
3x400/50
15,2
10,5
22
3 step
1 step
A-E-200
2 step
3 step
15,5
10,7
21
20,7
14,4
22
21,2
14,7
20
21,5
15
18
At inlet air temperature 10oC
Air curtains and air curtain-fan heater combo units
ELiS A 57
Control systems
TS regulation
T-box regulation
3-step fan speed regulator with thermostat
Intelligent controller with touch
screen
5
n/a
n/a
n/a
31
n/a
n/a
n/a
Controlling options
Manual 3-step air flow regulation
Controlling options
Heating / Ventilation
Operation depending on door contact and temperature
Weekly programmer
BMS
Switch-off delay
Idle speed mode
Integration with FLOWAIR System
Max. number of connected units
Via controller
Via 1 splitter RX
Via 2 splitters RX
Via 3 splitters RX
Type of fan
AC – standard 3-step fan
ELiS A air curtains
TS regulation
DCe
TS
DCm
SRQ
SRQ
or
min.
5×0,5 mm2
min.
2×0,5 mm2
LIYCY min. 3x0,5 mm2
A and B braided wire
pair max. 50 m
min.
3×0,5 mm2
min. 5×4,0 mm2
3x400 V/50 Hz
ELiS A-E
min. 3×1,0 mm2
230 V/50 Hz
ELiS A-N/W
power supply
power supply
max 5 devices
ELiS A
SRQ
power supply
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
58 ELiS A
Air curtains and air curtain-fan heater combo units
Control systems
ELiS A air curtains
T-box regulation
T-box
DCe
SRQ
DCm
SRQ
or
min.
2×0,5 mm2
min.
3×0,5 mm2
LIYCY min. 4x0,5 mm2
A and B braided wire
pair max. 50 m
LIYCY min. 3x0,5 mm2
A and B braided wire
pair max. 50 m
min. 5×4,0 mm2
3x400 V/50 Hz
ELiS A-E
min. 3×1,0 mm2
230 V/50 Hz
ELiS A-N/W
power supply
power supply
max 31 devices compatible
with FLOWAIR System
SRQ
power supply
Indexes ELiS A control systems
Name
T-box
TS
DCm
DCe
SR Q 2d -½
SR Q3 d- ½
Index
10799
10996
14207
14212
10803
10804
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
Air curtains and air curtain-fan heater combo units
ELiS A 59
Air curtains ELiS DUO
Air curtains ELiS DUO
Max. range(1) [m]
Heating capacity(2) [kW]
Air flow [m3/h]
Weight [kg]
Colour
Casing
(1)
(2)
2,5
15,5–29
1200–3700
23,9–41,1
grey (RAL 9006) / white (RAL 9010)
steel, plastic
Range of vertical isothermal air stream, at velocity limit above 2 m/s
For DUO-W at inlet/outlet water temperature 90/70oC, inlet air temperature 10oC
Application:
AIR CURTAIN
Buildings with high aesthetic values, wherever there is a need of heating the room and
ensuring air barrier on door opening simultaneously, e.g. in small grocery stores, gas
stations etc. ELiS DUO is an 2-in-1 unit, designed to operate indoors. Its main task is to
protect door opening. Additionally, the auxiliary air stream enables to heat the room.
FAN HEATER
AIR CURTAIN-FAN HEATER COMBO UNIT
Available types of units:
Available in 2 lengths: 1 m or 2 m.
Available in 2 verions:
W – curtain with water heat exchanger
Indexes ELiS DUO grey/white
Name
D UO -W-100
DUO -W-200
DUO -E-100
Index
14000/14270
–/14243
14014/14272
E – curtain with electric heaters
Special attributes
ADJUSTABLE AIR STREAM
QUIET FANS
BMS CONTROL SYSTEM
MODERN DESIGN
Air deflectors installed in the
outlet of heater section enable
to direct the warm air into the
occupied area. Variable angle of
defletors ensures to adjust the air
barrier to the door opening plane.
Radial fans are housed in the casing
made of light, durable and soundabsorbing material. They are characterized by quiet operation and low
power consumption in relation to
their efficiency.
Advanced control system makes
it possible to chain the units and
to easy control them by the intelligent building management system (BMS) as well as by dedicated
controllers.
Modern design of the unit came
into existence in cooperation with
an experienced team of industrial
designers.
Dimensions
DUO-/W/E-200
440(1)
390
DUO-/W/E-100
1125
(1)
2040
356
393
Concerns ELiS DUO-W
60 ELiS DUO
Air curtains and air curtain-fan heater combo units
Technical data
ELiS DUO-W-100
230/50
1,1
0,25
Power supply [V/Hz]
Max. power supply [A]
Max. power consumption [kW]
IP
Max. air flow stream of air curtain [m3/h]
Max. air flow stream of fan heater [m3/h]
Acoustic pressure level(1) [dB(A)]
Max. air steam range of air curtain(2) [m]
Max. air steam range of fan heater(3) [m]
Weight of unit [kg]
ELiS DUO-E-100
3x400/50
14,7
10,1
21
1400
ELiS DUO-W-200
230/50
1,85
0,43
3000
700
46
2,5
23,9
49
2,5
8
28,5
41,1
Acoustic pressure level measured for optimum installation height, on second step of efficiency, in the room with medium capability of sound absorption, capacity 500 m3,
at distance of 3 m from the unit
(2)
Range of vertical isothermal air stream, at velocity limit above 2 m/s
(3)
Range of horizontal isothermal air stream, at 0,5 m/s velocity limit
(1)
Installation
Two ways of console assembly.
or
max. 2,5 m
min. 0,2 m
ELiS air curtains are
equipped with holders for
installation using pins.
Indexes brackets
Name
bra ckets E LiS
Index
14250
Air curtains and air curtain-fan heater combo units
ELiS DUO 61
Heating capacities
ELiS DUO-W-100
Tp1
°C
0
5
10
15
20
0
5
10
15
20
0
5
10
15
20
0
5
10
15
20
Air curtain part
Qw
l/h
V
m3/h
PT
kW
800/1100/1400
12,1/14,9/17,2
11,2/13,7/15,9
10,3/12,6/14,7
9,4/11,6/13,4
8,6/10,5/12,2
800/1100/1400
10,4/12,8/14,8
9,5/11,7/14,8
8,6/10,6/12,3
7,8/9,5/11,1
6,9/8,5/9,8
800/1100/1400
8,7/10,7/12,4
7,8/9,6/11,1
6,9/8,5/9,9
6,1/7,5/8,7
5,2/6,4/7,5
800/1100/1400
7,0/8,5/9,9
6,1/7,5/8,6
5,2/6,4/7,4
4,3/5,3/6,2
3,5/4,3/5,0
Δpw
kPa
max. 1141
Tp2
o
C
max. 12,8
max. 976
max. 9,9
max. 811
max. 7,3
max. 646
max. 5,0
V
m3/h
Fan heater part
Qw
l/h
PT
kW
Tw1/Tw2 = 90/70oC
42/37/34
44/40/37
47/43/40
400/550/700
49/46/43
52/48/46
Tw1/Tw2 = 80/60oC
36/32/29
38/35/32
41/38/35
400/550/700
43/40/38
46/43/41
Tw1/Tw2 = 70/50oC
30/27/24
32/30/27
35/32/30
400/550/700
37/35/33
39/37/36
Tw1/Tw2 = 60/40oC
24/21/20
26/24/22
29/27/25
400/550/700
31/29/28
33/32/31
6,1/7,4/8,6
5,6/6,9/8,0
5,2/6,3/7,3
4,7/5,8/6,7
4,3/5,3/6,1
5,2/6,4/7,4
4,8/6,4/6,8
4,3/5,3/6,1
3,9/4,8/5,5
3,4/4,2/4,9
4,35/5,3/6,2
3,9/4,8/5,6
3,5/4,3/4,9
3/3,7/4,3
2,6/3,2/3,7
3,5/4,3/4,9
3,0/3,7/4,3
2,6/3,2/3,7
2,2/2,7/3,1
1,7/2,1/2,5
Δpw
kPa
Tp2
o
C
max. 12,8
42/37/34
44/40/37
47/43/40
49/46/43
52/48/46
max. 9,9
36/32/29
38/35/32
41/38/35
43/40/38
46/43/41
max. 7,3
30/27/24
32/30/27
35/32/30
37/35/33
39/37/36
max. 646
max. 5,0
24/21/20
26/24/22
29/27/25
31/29/28
33/32/31
Fan heater part
Qw
l/h
Δpw
kPa
Tp2
o
C
max. 18,9
34/30/27
36/33/30
39/36/33
42/39/36
45/42/40
max.14,5
29/26/23
32/29/26
34/32/29
37/35/33
40/38/36
max. 10,6
24/21/19
27/24/22
30/27/26
32/30/29
35/33/32
max. 7,2
19/17/15
22/20/19
25/23/22
27/26/25
30/29/28
max. 1141
max. 976
max. 811
ELiS DUO-W-200
Tp1
°C
0
5
10
15
20
0
5
10
15
20
0
5
10
15
20
0
5
10
15
20
Air curtain part
Qw
l/h
V
m3/h
PT
kW
1700/2250/3000
19/23/26,6
17,8/21,1/24,9
16,6/19,7/23,2
15,4/18,2/21,5
14,2/16,8/19,8
1700/2250/3000
16,3/19,4/22,8
15,1/17,9/21,1
13,8/16,5/19,7
12,6/15/17,7
11,2/13,6/16
1700/2250/3000
13,6/16,2/19
12,3/14,6/17,3
11,1/13,2/15,6
9,8/11,8/13,8
8,6/10,3/12,1
1700/2250/3000
10,8/12,9/15,1
9,6/11,4/13,4
8,4/9,9/11,7
7,1/8,4/9,9
5,8/6,9/8,2
Δpw
kPa
max. 1465
Tp2
o
C
max. 18,9
max.1252
max.14,5
max. 1039
max. 10,6
max. 826
max. 7,2
V
m3/h
PT
kW
Tw1/Tw2 = 90/70oC
34/30/27
36/33/30
39/36/33
400/550/700
42/39/36
45/42/40
Tw1/Tw2 = 80/60oC
29/26/23
32/29/26
34/32/29
400/550/700
37/35/33
40/38/36
Tw1/Tw2 = 70/50oC
24/21/19
27/24/22
30/27/26
400/550/700
32/30/29
35/33/32
Tw1/Tw2 = 60/40oC
19/17/15
22/20/19
25/23/22
400/550/700
27/26/25
30/29/28
4,7/5,8/6,6
4,4/5,3/6,2
4,1/4,9/5,8
3,8/4,6/5,4
3,5/4,2/5,0
4,1/4,8/5,7
3,8/4,5/5,3
3,5/4,1/4,9
3,2/3,8/4,4
2,8/3,4/4,0
3,4/4/4,7
3,1/3,7/4,3
2,8/3,3/3,9
2,5/2,9/3,5
2,2/2,6/3,0
2,7/3,2/3,8
2,4/2,9/3,4
2,1/2,5/2,9
1,8/2,1/2,5
1,4/1,7/2
max. 1465
max.1252
max. 1039
max. 826
To obtain operating parameters concerning other water temperatures, please contact Sales Office.
V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Tw1 –inlet water temperature
Tw2 –outlet water temperature
Qw – water stream flow in the heat exchanger
Δpw – water pressure drop in the heat exchanger
ELiS DUO-E-100
Curtain section
1 step
Power supply [V/Hz]
Rated current of unit(1) [A]
Heating capacity(1) [kW]
Air temperature rise for curtain (ΔT)(1) [°C]
(1)
9,1
6,3
23
2 step
9,4
6,5
21
Heater section
3 step
9,9
6,8
20
Curtain-heater combo unit
1 step
2 step
3 step
1 step
2 step
3 step
4,2
2,9
23
3x400/50
4,5
3,1
21
4,8
3,3
20
13,3
9,2
23
13,9
9,6
21
14,7
10,1
20
At inlet air temperature 10oC
62 ELiS DUO
Air curtains and air curtain-fan heater combo units
Control systems
TS regulation
T-box regulation
3-step fan speed regulator with thermostat
Intelligent controller with touch
screen
5
n/a
n/a
n/a
31
n/a
n/a
n/a
Controlling options
Manual 3-step air flow regulation
Controlling options
Heating / Ventilation
Operation depending on door contact and temperature
Weekly programmer
BMS
Switch-off delay
Idle speed mode
Integration with FLOWAIR System
Max. number of connected units
Via controller
Via 1 splitter RX
Via 2 splitters RX
Via 3 splitters RX
Type of fan
AC – standard 3-step fan
ELiS DUO air curtain-fan heater combo unit
TS regulation
TS
curtain
TS
heater
DCe
SRQ
DCm
SRQ
or
min.
5×0,5 mm2
min.
5×0,5 mm2
min.
2×0,5 mm2
min.
3×0,5 mm2
LIYCY min. 3x0,5 mm2
A and B braided wire
pair max. 50 m
min. 5×4,0 mm2
3x400 V/50 Hz
ELiS DUO-E
min. 3×1,0 mm2
230 V/50 Hz
ELiS DUO-N/W
power supply
power supply
max 5 devices
ELiS DUO
SRQ
power supply
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
Air curtains and air curtain-fan heater combo units
ELiS DUO 63
Control systems
ELiS DUO air curtain-fan heater combo unit
T-box regulation
DCe
T-box
SRQ
DCm
SRQ
or
min.
3×0,5 mm2
min.
2×0,5 mm2
LIYCY min. 4x0,5 mm2
A and B braided wire
pair max. 50 m
LIYCY min. 3x0,5 mm2
A and B braided wire
pair max. 50 m
min. 5×4,0 mm2
3x400 V/50 Hz
ELiS DUO-E
min. 3×1,0 mm2
230 V/50 Hz
ELiS DUO-N/W
power supply
power supply
max 31 devices compatible
with FLOWAIR System
SRQ
power supply
Indexes ELiS DUO control systems
Name
T-box
TS
DCm
DCe
SR Q2d -½
SR Q3 d- ½
Index
10799
10996
14207
14212
10803
10804
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
64 ELiS DUO
Air curtains and air curtain-fan heater combo units
Air curtains ELiS G
Air curtains ELiS G
Max. range(1) [m]
Heating capacity(2) [kW]
Air flow [m3/h]
Weight [kg]
Colour
Casing
(1)
(2)
7,5
29,5–33,1
6200–8600
43–67
silver-graphite
steel, plastic
Range of vertical isothermal air stream, at velocity limit above 3 m/s
At inlet/outlet water temperature 90/70oC, inlet air temperature 10oC
Application:
Industrial buildings like: warehouses, logistics centers etc. ELiS G units are designed for
vertical as well as horizontal installation in relation to the gate opening.
Dostępne typy urządzeń:
Available types of units: 1,5 m or 2 m.
Available in 3 versions:
Indexes ELiS G1-N
Name
G1-N-150
G1-N-200
Index
14220
14221
N – curtain without heat exchanger (ambient)
W – curtain with water heat exchanger
E – curtain with electric heaters
Indexes ELiS G1-W
Name
G1-W-150
G1-W-200
Index
14224
142 25
Indexes ELiS G1-E
Name
G1-E-150
G1-E-200
Index
14226
14227
Special attributes
CASING OF THE UNIT
INSTALLATION HOLDERS AS
STANDARD
HIGHLY-EFFICIENT FANS
BMS CONTROL SYSTEM
Made of galvanized steel and plastic elements.
Curtains have installation elements
as standard equipment.
The curtain comes with highlyefficient 3-step axial fans, with
protection degree IP54.
Curtains are equipped with simple power and control system
with possibility of optional connection to BMS.
Dimensions
G1-150
G1-200
550
639
307(1)
50(1)
1562
(1)
2078
125
Concerns ELiS G-W
Air curtains and air curtain-fan heater combo units
ELiS G 65
Technical data
G1-N-150
Power supply [V/Hz]
Max. current consumption [A]
Max. power consumption [kW]
IP
Max. air flow stream of air curtain [m3/h]
Max. acoustic pressure level(1) [dB(A)]
Max. air stream range(2) [m]
Weight of unit [kg]
G1-W-150
230/50
2,8
0,64
6500
7,5
43
G1-E-150
G1-N-200
3x400/50
17,0
12,0
54
6200
54
7
47,4
G1-W-200
230/50
4,2
0,96
6300
8600
7
49,8
7,5
58
G1-E-200
3x400/50
29
20
54
8100
56
7
62
8200
7
67
Acoustic pressure level measured for optimum installation height, on second step of efficiency, in the room with medium capability of sound absorption, capacity 500 m3,
at distance of 3 m from the unit
(2)
Range of vertical isothermal air stream, at velocity limit above 3 m/s
(1)
Installation
Possibility of vertical installation using
standard brackets.
max. 7,5 m
Curtains are equipped with holders for
installation using pins.
Brackets make it possible to install
the unit on the wall.
max. 13 m
66 ELiS G
Air curtains and air curtain-fan heater combo units
Heating capacities
ELiS G 150
Tp1
°C
PT
kW
0
5
10
15
20
27,0
25,0
22,9
21,0
19,0
0
5
10
15
20
Qw
l/h
∆pw
kPa
Tp2
°C
PT
kW
Tw1/Tw2 = 90/70°C
1190
5
1100
6
1010
5
920
4
840
4
19,0
22,5
26,5
30,5
34,0
23,2
21,2
19,2
17,3
15,4
31,2
28,8
26,4
24,1
21,9
Tw1/Tw2 = 90/70°C
1370
7
1270
6
1170
5
1060
6
960
5
17,0
21,0
25,0
29,0
33,0
26,8
24,5
22,2
19,9
17,7
0
5
10
15
20
34,8
32,1
29,5
27,0
24,5
Tw1/Tw2 = 90/70°C
1530
9
1420
8
1300
6
1190
5
1080
6
15,5
19,5
23,5
28,0
32,0
29,9
27,3
24,8
22,2
19,8
Tp1
°C
PT
kW
Tp2
°C
PT
kW
0
5
10
15
20
29,3
27,1
24,9
22,7
20,6
Tw1/Tw2 = 90/70°C
1290
6
1190
5
1100
6
1000
5
910
4
17,5
21,5
25,5
29,5
33,5
25,3
23,0
20,9
18,8
16,7
0
5
10
15
20
33,2
30,6
28,2
25,7
23,3
Tw1/Tw2 = 90/70°C
1460
8
1350
7
1240
6
1130
5
1030
5
16,0
20,0
24,5
28,0
32,0
28,5
26,0
23,6
21,2
18,9
0
5
10
15
20
38,9
36,0
33,1
30,2
27,4
Tw1/Tw2 = 90/70°C
1720
9
1580
7
1460
8
1330
7
1210
6
14,5
18,5
22,5
26,5
31,0
33,5
30,5
27,7
24,9
22,1
Qw
l/h
∆pw
Tp2
PT
kPa
°C
kW
V = 4000 m3/h (1st step)
Tw1/Tw2 = 80/60°C
1020
5
16,0
19,5
930
5
20,0
17,5
850
4
24,0
15,6
760
5
27,5
13,6
680
4
31,5
11,8
V = 5100 m3/h (2nd step)
Tw1/Tw2 = 80/60°C
1180
5
14,5
22,4
1070
6
18,5
20,1
970
5
22,5
17,9
880
4
26,5
15,7
780
3
30,5
13,5
V = 6200 m3/h (3rd step)
Tw1/Tw2 = 80/60°C
1310
7
13,5
25,0
1200
6
17,5
22,4
1090
6
21,5
20,0
980
5
25,5
17,5
870
4
29,5
15,1
Qw
l/h
∆pw
kPa
Tp2
°C
PT
kW
Qw
l/h
∆pw
kPa
Tp2
°C
Tw1/Tw2 = 70/50°C
850
4
770
3
680
4
600
3
520
2
13,5
17,5
21,0
22,5
29,0
15,7
13,7
11,8
10,0
8,1
Tw1/Tw2 = 60/40°C
680
4
600
3
520
2
430
4
350
3
11,0
14,5
18,5
22,5
26,0
Tw1/Tw2 = 70/50°C
980
5
880
4
780
3
690
4
590
3
12,0
16,0
20,0
24,0
28,0
18,0
15,8
13,6
11,4
9,3
Tw1/Tw2 = 60/40°C
790
3
690
4
590
3
500
2
410
3
10,0
14,0
17,5
21,5
25,5
Tw1/Tw2 = 70/50°C
1090
6
980
5
870
4
770
3
660
4
11,0
15,5
19,5
23,5
27,5
20,1
17,6
15,1
12,7
10,4
Tw1/Tw2 = 60/40°C
880
4
770
3
660
4
550
3
450
4
9,0
13,0
17,0
21,0
25,0
Tp2
°C
PT
kW
Tw1/Tw2 = 70/50°C
920
5
830
4
740
5
650
4
560
3
13,0
16,5
20,5
24,5
28,5
17,0
14,9
12,8
10,8
8,8
Tw1/Tw2 = 60/40°C
740
5
650
4
560
3
470
4
380
3
10,5
14,0
18,0
22,0
25,5
Tw1/Tw2 = 70/50°C
1040
6
940
5
830
4
730
5
630
4
11,5
15,5
19,5
23,5
27,5
19,2
16,8
14,5
12,1
9,9
Tw1/Tw2 = 60/40°C
840
4
730
5
630
4
530
3
430
4
9,4
13,5
17,5
21,5
25,0
Tw1/Tw2 = 70/50°C
1220
6
1100
6
980
5
860
4
740
5
10,0
14,5
18,5
22,5
26,5
22,4
19,6
16,9
14,2
11,6
Tw1/Tw2 = 60/40°C
980
5
860
4
740
5
620
3
500
2
8,0
12,5
16,5
20,5
24,5
ELiS G 200
Qw
l/h
∆pw
kPa
Qw
l/h
∆pw
Tp2
PT
kPa
°C
kW
V = 5100 m3/h (1st step )
Tw1/Tw2 = 80/60°C
1110
6
15,5
21,1
1010
5
19,0
19,0
920
4
23,0
16,9
820
4
27,0
14,8
730
5
31,0
12,8
V = 6200 m3/h (2nd step)
Tw1/Tw2 = 80/60°C
1250
6
14,0
23,9
1140
5
18,0
21,4
1040
6
22,0
19,0
930
5
26,0
16,7
830
4
30,0
14,4
V = 8100 m3/h (3rd step)
Tw1/Tw2 = 80/60°C
1470
8
12,0
28,0
1340
7
16,5
25,1
1220
6
20,5
22,3
1090
6
24,5
19,6
970
5
28,5
16,9
Qw
l/h
∆pw
kPa
Qw
l/h
∆pw
kPa
Tp2
°C
To obtain operating parameters concerning other water temperatures or air curtains with more heating capacity, please contact Sales Office.
V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Tw1 –inlet water temperature
Tw2 –outlet water temperature
Qw – water stream flow in the heat exchanger
Δpw – water pressure drop in the heat exchanger
1st step
Power supply [V/Hz]
Rated current(1) [A]
Heating capacity(1) [kW]
Air temperature rise ∆T(1) [°C]
(1)
G1-E-150
2nd step
3rd step
1st step
G1-E-200
2nd step
3rd step
23
16,5
12
26
18,5
9
29
20,0
7
3x400/50
13
9,0
12
15
10,5
9
17
12,0
7
At inlet air temperature 10oC
Air curtains and air curtain-fan heater combo units
ELiS G 67
Control systems
TS regulation
T-box regulation
3-step fan speed regulator with thermostat
Intelligent controller with touch
screen
1
3
6
9
31
n/a
n/a
n/a
Controlling options
Manual 3-step air flow regulation
Controlling options
Heating / Ventilation
Operation depending on door contact and temperature
Weekly programmer
BMS
Switch-off delay
Idle speed mode
Integration with FLOWAIR System
Max. number of connected units
Via controller
Via 1 splitter RX
Via 2 splitters RX
Via 3 splitters RX
Type of fan
AC – standard 3-step fan
Control systems
ELiS G gate curtains
TS regulation
Curtain control is provided by the overriding controller – DCm door contact. In addition, it is possible to connect a valve to the system, which shuts-off the
water supply.
SRQ
DCm
min.
2×0,5 mm2
SRQ
min.
3×0,5 mm2
ELiS G-W
TS
min. 5×6,0 mm2
3x400 V/50 Hz
ELiS G-E
power supply
RX
min. 2×1,5 mm2
ELiS G-E
min.
5×0,5 mm2
min.
5×1,5 mm2
min. 3×1,5 mm2
230 V/50 Hz
ELiS G-N/W/E
power supply
68 ELiS G
power supply
RX
max. 3 units
ELiS G
min.
5×0,5 mm2
max. 3 units
ELiS G
power supply
Air curtains and air curtain-fan heater combo units
Control systems
ELiS G gate curtains
T-box regulation
SRQ
DCm
min.
3×0,5 mm2
T-box
min.
2×0,5 mm2
min. 5×6,0 mm2
3x400 V/50 Hz
ELiS G-E
LIYCY min. 4x0,5 mm
A and B braided wire
pair max. 50 m
2
power supply
RX
min. 2×1,5 mm2
ELiS G-E
DRV
min.
4×0,5 mm2
min.
5×1,5 mm2
power supply
~230 V
max. 3 units
ELiS G
min. 3×1,5 mm2
230 V/50 Hz
ELiS G-N/W/E
power supply
LIYCY min. 3x0,5 mm2
A and B braided wire
pair max. 50 m
SRQ
DRV
power supply
RX
max. 3 units
ELiS G
power supply
~230 V
power supply
Indexes ELiS G control system
Name
TS
T- box
RX
DCm
SR Q2d -¾
SR Q3 d- ¾
DRV ELiS
Index
10996
10799
11779
14207
10788
10805
90541
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
Air curtains and air curtain-fan heater combo units
ELiS G 69
70
www.flowair.com
Ductless ventilation
with heat recovery
www.flowair.com
71
Ventilation unit OXeN
Ventilation unit OXeN
Air flow [m³/h]
Heat recovery efficiency [%]
Weight [kg]
Casing
Colour
150–1200
up to 78,9
67,2–73,4
EPP (expanded polypropylene)
grey
Application:
Medium cubature buildings, where fresh air supply is demanded and where air duct
installation is unjustified, e.g. gas stations, stores, workshops, warehouses, sports halls etc.
Available types of units:
OXeN ventilation unit is:
X2-N-1.2-V – unit without additional air heating, for installation on the wall,
• the easiest way to create a mechanical ventilation system
with heat recovery,
X2-W-1.2-V – unit with air heating by water heater, for installation on the wall,
• a ductless ventilation system, which allow significant
reduction of investment costs,
X2-N-1.2-H – unit without additional air heating, for installation under the ceiling,
• a highly-efficient heat recovery system, which reduces
operation costs.
X2-W-1.2-H – unit with air heating by water heater, for installation under the ceiling.
Indexes OXeN
Name
X2-N - 1.2-V
X2-W-1. 2-V
X 2-N-1. 2-H
X 2-W-1. 2-H
Index
30018
30019
30035
30032
Special attributes
2014
X2-FLOW
MULTI-FAN TECHNOLOGY
ECODESIGN
AWARDED SOLUTIONS
High efficiency of heat recovery
was achieved thanks to use of
two cross heat exchangers. They
are made of aluminium, and are
highly-resistant to corrosion.
Two sections of diagonal fans,
each section consisting of 3 fans,
ensure regular distribution of air
stream on entire surface of the
heat exchanger, silent operation
and lower power consumption.
OXeN ventilation unit meets all
of the requirements for minimum
efficiency of heat recovery and
ecodesign of ventilation systems
contained in the EU Commission
Regulation No. 1253/2014 of
7 July 2014 on the implementation of the Directive of The European Parliament and Council No.
2009/125/EC.
Oxen ventilation unit has been
recognized as a model of complex designing by the chapters
of most prestigious competitions
in the world of design. Experts
praised the project for the quality,
innovation and ergonomics.
Dimensions
For installation on the wall:
OXeN X2-W-1.2-V
OXeN X2-N-1.2-V
72 OXeN
1020
890
840
760
830
1370
1180
For installation under the ceiling:
OXeN X2-W-1.2-H
OXeN X2-N-1.2-H
Ductless ventilation with heat recovery
Technical data
X2-W-1.2-V
Max. air flow stream inlet/outlet(1) [m3/h]
Air stream range(2) [m]
Acoustic pressure level(3) [dB(A)]
Power supply [VAC/Hz]
Max. current consumption [A]
Max. power consumption [W]
Weight of unit [kg]
Weight of unit filled with water [kg]
Operating temperature [oC]
IP
Filter class
Thermal efficiency dry/wet(4) [%]
X2-N-1.2-V
X2-W-1.2-H
X2-N-1.2-H
72,6
73,4
70,2
–
1200
15
49
230/50
1,9
420
69,6
70,4
67,2
–
5–45
42
EU4
68,4 / 78,9
Air flow during operation with EU4 filter and OxS air inlet
Range of horizontal isothermal air stream, at 0,2 m/s velocity limit
(3)
Acoustic pressure level at the distance of 5 m from the unit, in the room of medium capability of sound absorption and 500 m3 of cubature
(4)
According to directive 2009/125/EC measured with balanced mass flow, an indoor-outdoor dry air temperature difference of 20 K
(1)
(2)
Parameters of water heat exchanger
Tp1
°C
-5
0
5
10
15
20
PT
Qw ∆pw Tp2
kW
l/h
kPa
°C
Tw1/Tw2 = 90/70°C
13,3 587 12,1
28
12,5 552 10,9
31
11,7 518
9,7
34
10,9 483
8,5
37
10,2 449
7,5
40
9,4
414
6,5
43
PT
Qw ∆pw Tp2
kW
l/h
kPa
°C
Tw1/Tw2 = 80/60°C
11,6 507
9,6
24
10,8 473
8,5
27
10,0 438
7,4
30
9,2
404
6,4
33
8,4
369
5,4
35
7,6
334
4,5
38
PT
Qw ∆pw Tp2
kW
l/h
kPa
°C
Tw1/Tw2 = 70/50°C
9,8
429
7,3
19
9,0
394
6,3
22
8,2
359
5,3
25
7,4
324
4,4
28
6,6
289
3,6
31
5,8
253
2,9
34
PT
Qw ∆pw Tp2
kW
l/h
kPa
°C
Tw1/Tw2 = 60/40°C
8,0
350
5,3
15
7,2
315
4,4
18
6,4
280
3,6
21
5,6
244
2,8
24
4,8
208
2,1
27
3,9
171
1,5
30
PT
Qw ∆pw Tp2
kW
l/h
kPa
°C
Tw1/Tw2 = 50/30°C
6,2
270
3,5
10
5,4
235
2,7
13
4,6
199
2,0
16
3,7
161
1,4
19
2,8
122
0,9
22
1,3
56
0,2
23
V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Tw1 –inlet water temperature
Tw2 –outlet water temperature
Qw – water stream flow in the heat exchanger
Δpw –water pressure drop in the heat exchanger
Ductless ventilation with heat recovery
OXeN 73
Nomogram of heating capacity — for max. air flow 1200 m3/h
10
12
14
16
18
20
22
24
T2 – inside temperature [oC]
5
0
T1– outside temperature [oC]
-5
1
-10
2
-15
-20
-25
-30
-35
-40
0
2
4
3
6
8
10
12
14
16
18
20
Pr – heat recovery capacity [kW]
Temperature of
heating medium:
Pc – total heating capacity [kW]
35
Tw1/Tw2 = 90/70°C
Tw1/Tw2 = 80/60°C
Tw1/Tw2 = 70/50°C
Tw1/Tw2 = 60/40°C
Tw1/Tw2 = 50/30°C
30
25
20
15
5
4
10
5
1.Specify outside temperature
2.Specify inside temperature
3.Read the capacity of heat recovery Pr (total heating capacity of OXeN without water heat exchanger X2-N-1.2)
4.Specify heating medium temperature
5.Read the total heating capacity Pc (for OXeN with water heat exchanger X2-W-1.2)
Air parameters: supplied air RH 90%, removed air RH 30%, air flow 1200 m3/h
74 OXeN
Ductless ventilation with heat recovery
Nomogram of air flow temperature — for max. air flow 1200 m3/h
24
22
20
18
16
14
5
12
10
T2 – inside temperature [oC]
0
T1– outside temperature [oC]
-5
2
1
-10
-15
-20
-25
-30
-35
-40
-8
-6
-4
-2
0
2
4
6
3
8
10
12
14
16
18
20
T3 – air flow temperature OXeN X2-N-1.2 [oC]
Temperature of
heating medium:
T4 – air flow temperature OXeN X2-W-1.2 [oC]
45
Tw1/Tw2 = 90/70°C
40
Tw1/Tw2 = 80/60°C
35
Tw1/Tw2 = 70/50°C
30
25
5
4
Tw1/Tw2 = 60/40°C
Tw1/Tw2 = 50/30°C
20
15
10
5
1.Specify outside temperature
2.Specify inside temperature
3.Read the air flow temperature for OXeN without water heat exchanger
4.Specify heating medium temperature
5.Read the air flow temperature for OXeN with water heat exchanger
Air parameters: supplied air RH 90%, removed air RH 30%, air flow 1200 m3/h
Ductless ventilation with heat recovery
OXeN 75
Installation on the wall
Installation options
760
OXeN
OxC
with control
system
wall crossing
Air inlet
1180
Air outlet
1370
min. 1,5 m
OxS
air inlet/outlet
2,0–4,0 m
Air inlet
into the room
Air outlet
from the room
Elements for installation
OxS
OxC
OxE
OxC – wall crossing, element
connecting unit with OxS
air inlet/outlet
Material: EPS
Weight: 0,7 kg
Index: 30022 (1 pc. in set)
Max. wall thickness for
single OxS is 190 mm; for
thicker walls use several OxS
elements.
220
87
0
440
Ø15,5 mm
Gravitational
condensate discharge
OxS – wall-mounted air inlet/outlet
Material: galvanized steel
Weight: 18,4 kg
Index: 30020
Possibility to install the air outlet
on the left or on the right side.
OxE – extension duct – air outlet
Material: galvanized steel
Weight: 6,1 kg
Index: 30021
250
In order to maintant the 1,5m
distance between air inlet and
outlet, use two OxE elements.
Max. 5 OxE elements can be
connected together.
250
87
12
00
60
0
490
0
24
00
15
00
490
OxE
OxE
76 OXeN
Ductless ventilation with heat recovery
Installation under the ceiling
Installation options
OxS-H
roof air inlet/outlet
760
Air inlet
1370
Air outlet
OxE-H
extension duct
3,0–5,0 m
Air outlet from
the room
OxC2-H
joining adapter
OXeN
Air inlet into the room
with control system
Elements for installation
OxS-H – roof-mounted air inlet/outlet
OxS-H
Material: galvanized steel
Weight: 14,8 kg
Index: 30034
0,4-1,5 m
OxE-H
880
500
OxC2-H
0
80
Tinsmith works and roof seal
must be performed
0
40
Ø 9 mm
Condensate discharge
by built-in pump
OxC2-H – Adapter, joins the unit with OxE-H extension duct (1 pc. in set)
OxE-H – extension duct
Material: galvanized steel
Material: galvanized steel
Weight: 3,5 kg
Weight: 19,0 kg
Max. 5 OxE-H elements can
be connected together.
Index: 30036
100
840
840
1000
400
82
0
0
40
5
38
0
84
0
40
Ductless ventilation with heat recovery
OXeN 77
Control systems
Unit is equipped with a complete control and protection system. Control of operation parameters is performed by the T-box controller.
Basic functions:
• stepless regulation of air flow,
• maintaining steady temperature of air supplied into the room,
• operation mode without heat recovery – by-pass,
• control over filter contamination degree by operation time counter,
• weekly programmer.
T-box
intelligent controller
with touch screen
Fresh air Fan heater part
temperature
sensor
Cutting-off dampers actuator
By-pas Fan heater part s actuator
Removed air temperature
sensor
Central power and control system
3-way valve with actuator
(applies to OXeN X2-W-1.2-V/H)
Heating water temperature sensor
(applies to OXeN X2-W-1.2-V/H)
Supplied air temperature
sensor
Ambient air temperature
sensor
OXeN ventilation unit
T-box regulation
LIYCY min. 3x0,5mm2,
A and B braided wire pair max. 50 m
T-box
LIYCY min. 4x0,5mm2,
A and B braided wire pair max. 50 m
max 31 devices compatible
with FLOWAIR System
min. 3×1 mm2
power supply
~230 V
power
supply~230 V
Indexes OXeN
Name
T-box
Index
10799
Accurate diagrams of electrical connections are presented in documentation available on the website www.flowair.com.
78 OXeN
Ductless ventilation with heat recovery
notepad
www.flowair.com
79
2016 v.1
CONTACT
Our knowledgable and qualified sales consultants will help you to choose the best type and
quantity of units to best match the unique requirements of the building.
DISTRIBUTOR
PRODUCER
Muirfield Drive, Naas Road, Dublin 12, Ireland
Tel. +353 1 4191919, Fax. +353 1 4584806
[email protected]
ul. Chwaszczyńska 151E, 81-571 Gdynia
Tel. +48 58 627 57 20, Fax. +48 58 627 57 21
[email protected]
www.hevac.ie
www.flowair.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement