Teaching Solution
Operating & Maintenance Manual
Teaching Solution
Corporation
Contents
Intended Use/Introduction3
Vertical Flat Wall4
Horizontal Sapphire5
Air Compressor6
Secondary Products7
Oil Fill Up Guide
8-9
Installation Guide
10 - 15
Moisture Trap Maintenance
16 - 17
Warranty Policy18
Notes19
2
Amico Beds
Intended Use
The following is an assembly reference guide for the Amico Teaching Solution. This guide shows the step by step process
to assemble and operate the Amico Teaching Solution. It shall guide users in assembling Amico Secondary Products
onto the Teaching solution, and shall show how to correctly connect the air compressor to the Teaching Solution.
All parts needed in the assembly are shown under the components section of this guide, and all steps required
for correct assembly can be found under the installation section. If users shall experience any difficulties with this assembly,
please contact Amico Beds for assistance.
This manual provides instructions required for normal operation of the Teaching Solution from Amico Beds
Corporation. Prior to operation of this Teaching Solution, it is important that this manual is read and that all safety
aspects contained in this manual are strictly adhered to.
Introduction
The Amico Teaching Solution has a simple design and incorporates distinctive features, which simulates a real
world medical environment for students.
The Teaching Solution comes in either a Horizontal Sapphire or a Vertical Flat wall. The floor stand which is the base
of the Teaching Solution shall allow for mobility with relative ease. The Teaching Solution includes fully functional
Secondary Products in order to provide students with a more realistic experience.
Amico Secondary Products such as an oxygen flowmeter, medical air flowmeter, vacuum regulator, vacuum canister
and humidifier bottle also helps to assist in creating a simulated medical environment for students to train and sharpen
their skills.
www.amico.com
3
Vertical Flatwall
2
1
3
5
10
6
4
8
7
11
9
12
Item
4
Description
Item
Description
1
Oxygen Outlet
7
Nurse Call Cover
2
Medical Air Outlet
8
Vacuum Switch
3
Vacuum Outlet
9
Mobile Floor Stand
4
Vacuum Outlet
10
Normal Duplex Receptacle
5
Medical Air Outlet
11
Compressed Air Outlet
6
Oxygen Outlet
12
Emergency Duplex Receptacle
Amico Beds
Horizontal Sapphire
9
2
4
6
7
1
3
5
8
Item
Description
Item
Description
1
Emergency Duplex Receptacle
6
Medical Air Outlet
2
Vacuum Switch
7
Compressed Air Outlet
3
Vacuum Outlet
8
Mobile Floor Stand
4
Nurse Call Cover
9
Oxygen Outlet
5
Light (Optional - *Not shown)
www.amico.com
5
Air Compressor
5
6
1
2
3
4
7
Item
6
Description
Item
Description
1
Tank Gauge
5
Oil Cap
2
Knob
6
ON / OFF Switch
3
Regulator Gauge
7
Compressor Oil (one bottle included)
4
DISS Hose Connection
Amico Beds
Secondary Products
1
3
2
6
5
Item
4
Description
7
Item
Description
1
Oxygen Flowmeter
5
Humidifier Bottle
2
Air Flowmeter
6
Horizontal Vacuum Slide (Sapphire Series)
3
Vacuum Regulator
7
Vertical Vacuum Slide (Flatwall)
4
Vacuum Canister
www.amico.com
7
Air Compressor Oil Fill Up Guide
3
2
1
Item
Description
1
Air Compressor
2
Oil Cap / Cover
3
Compressor Oil: Synthetic Oil (24 oz)
CAUTION: Ensure that the air compressor is not plugged into an electrical socket and that the power switch is in
the OFF position throughout the process of filling the air compressor with oil. Failure to do so may result in
damage to the compressor, and/or serious injury to the user.
1.
8
Remove the Oil Cover from the compressor.
This shall expose the oil compartment.
Amico Beds
1.
Remove the RED safety cap on the compressor oil
bottle. Cut the tip of the exposed mouth of the
bottle using a sharp object.
2.
Pour in no more than 18 ounces of the oil from the
bottle into the exposed oil compartment. More than
this will cause an overflow of oil and can damage
the compressor. The scale etched on the side of the
bottle shall aid in determining the amount of oil that
is used.
www.amico.com
9
Installation
CAUTION: Ensure that all power switches are in the OFF position prior to commencing the installation of the
Amico Teaching Solution. DO NOT plug in any electrical cords until instructed to do so.
1.
Attach the compressor hose to the DISS
connection on the Air Compressor.
Use a 7/8” wrench to ensure that the hose is
securely fastened onto the DISS connection.
This shall ensure that the compressor shall
operate effectively.
2.
Connect the other end of the hose to the
Compressed Air DISS Outlet. Using a 7/8”
wrench should help ensure that the hose
is fastened securely to the outlet.
For the Sapphire Series Teaching Solution,
the compressed air outlet shall be located
on the front or rear of the unit, while the
Flatwall Teaching Solution shall have the
­compressed air outlet located on the side
of the unit.
Rear Connection
Flatwall
10
Amico Beds
Sapphire Series
3. Install the Horizontal Vacuum Slide by holding the lever in and place the vacuum slide at an angle so that the
Vacuum Slide fits into the rail of the Teaching Solution. Continue to hold the lever and place the vacuum slide
in the upright position and then release the lever. This shall allow the horizontal vacuum slide to remain
upright securely. In order to remove the horizontal vacuum slide from the Teaching Solution, hold the lever,
tilt and gently tug the vacuum slide off the rail.
4. When installing the Vertical Vacuum Slide on the Teaching Solution, ensure that the vertical Vacuum Slide is in
the open position (unscrewed). Place the vertical vacuum slide onto the side rails of the Flatwall. Once in, turn
the knob on the side to securely fasten the vacuum slide into position. If done correctly, the vertical vacuum
slide shall sit securely on the Teaching Solution. In order to remove the vacuum slide, unscrew the black knob
found on the side until it is loose and remove.
www.amico.com
11
5.
Place the Vacuum Canister in the Vacuum
Canister Holder (supplied by Amico). Take
the Canister and align it with the vacuum
slide and slide the canister into the
vacuum slide. If the Canister is aligned
correctly with the vacuum slide, the
Canister holder shall slide right into the
vacuum slide and fit in securely.
6.
Place the oxygen Flowmeter, Medical Air
Flowmeter and Vacuum Regulator onto
the corresponding outlets. The Amico
Secondary Products are ­­gas-specific.
In order to remove the oxygen Flowmeter,
medical air Flowmeter and vacuum regulator,
simply turn the Ohmeda adaptor clockwise
and when loose, proceed to gently tug off
the Teaching Solution.
Ohmeda Adaptor
12 Amico Beds
7.
Attach the Humidifier Bottles by screwing the
accessories to the bottom of the oxygen and medical
air Flowmeters.
8.
Connect the vacuum hose (optional) from the the exposed mouth/nipple of the vacuum regulator to the
mouth of the vacuum canister. The vacuum canister lid shall indicate which mouth is intended for the vacuum
hose. In order for the vacuum to create suction in the vacuum canister, ensure that all the exposed mouths are
closed, except for the mouth that will house the hose for the patient.
www.amico.com
13
CAUTION: Users shall now connect all power cords to electrical outlets, however ensure that all power switches
are in the OFF position until instructed to do so.
9.
Turn the power switch on the air compressor ON. The switch is located above the tank gauge. Once the air
compressor has been turned ON, use the Compressor Pressure Knob to change the pressure of the compressed
air being released to 50psi. The Compressor Gauge shall indicate the pressure.
On / Off Switch
Compressor Gauge
&
Compressor Pressure Knob
14 Amico Beds
10.
In order to use the vacuum application of
the Teaching Solution, flip the Vacuum
Switch DOWN to turn ON the unit. This
shall allow the Teaching Solution to make
use of its vacuum application.
OFF position
ON position
The Amico Teaching Solution is now ready for use.
www.amico.com
15
Air Compressor Moisture Trap Maintenance
Maintaining the air compressor is an essential task that should not be neglected. In order to ensure that the air
compressor operates effectively, adhere to all of the following procedures for the air compressor to operate at full
capacity and with minimal problems.
Air Compressor Bleed Valve
Moisture Trap
Oil Level
Coalescing Cartridge
Moisture Trap Bleed Valve
16
Amico Beds
Air Compressor Maintenance Checklist
1
Drain the water collected in the moisture trap: (the
operations are to be done with the tank under pressure).
2
Remove the condensate that has collected in the air compressor tank.
To empty the tank, put it under pressure, take the compressor
to a place where the water will not damage the floor, tip the
compressor slightly forward and open the moisture trap
bleed valve.
3
Check the compressor efficiency: possible connectors
slackening, pressure hose wear, screws tightening electric
circuit efficiency, etc.
4
Clean the compressor with a soft cloth. Dust and dirt prevent
the compressor from cooling.
5
Oil level check
6
Check the air compressor bleed valve by pulling the ring
gently when there is pressure in the tank.
7
Check the moisture trap. Replace it if its necessary.
8
Disassemble the coalescing cartridge contained in the moisture
trap. This operation must be done with the tank completely
out of pressure.
Monthly
Yearly
3 months
6 months
ATTENTION: Maintenance of the compressor per the checklist is mandatory. Failure to do so will result in undue
wear and eventual malfunction, which in turn voids warranty.
www.amico.com
17
Teaching & Training
Warranty Policy
Amico Teaching and Training warrants its Patient Equipment to be free from defects in material and workmanship for a period
of twelve (12) months from the date of shipment. Within this period Amico will provide the parts for repair or replacement of
defective parts at Amico’s cost. Shipping and Installation costs will be borne by the Customer.
This warranty is valid only when the product has been properly installed according to Amico specifications used in a normal
manner and serviced according to factory recommendations. It does not cover failures due to damage which occurs in shipments
or failures which resulted from accidents, misuse, abuse, neglect, mishandling, alteration, misapplication or damage that may
be attributable to acts of God.
Amico shall not be liable for incidental or consequential damages resulting from the use of the equipment.
All claims for warranty must first be approved by Amico. A valid Return Goods Authorization (RGA) number must be obtained
from Amico prior to commencement of parts being shipped back for any service work. Failure to do so will result in parts being
sent back at the customer’s expense.
18 Amico Beds
85 Fulton Way, Richmond Hill, ON L4B 2N4, Canada
71 East Industry Court, Deer Park, NY 11729, USA
Notes
www.amico.com
19
www.amico.com
Amico Beds | www.amico.com
85 Fulton Way, Richmond Hill
Ontario, L4B 2N4, Canada
Toll Free Tel: 1.877.462.2697
Toll Free Fax: 1.866.440.4986
Tel:905.764.0800
Fax:905.764.0862
Email:[email protected]
TTS-OM-TEACHING 01.15.2014
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement